Odyssey 红外荧光扫描成像系统培训手册

合集下载

奥宝AOI-Discovery-Training-操作手册

奥宝AOI-Discovery-Training-操作手册
找出缺点问题
University
参考资料 reference
Nominal line 10 mil Minimum line 9, maximum 12
精确完整的reference
Ground area Minimum - 3 mil maximum + 2 mil
Nominal line 3 mil Minimum line 2.5
Customer Training A
online
B
C
D
pad
model
online drill
reference drill
University
检测机理-Clearance
在reference中,记录以下有关Clearance的信息: 位置(实际和将来的) 大小 Clearance的类型=Physical or Logical Physical: 实际板面上有clearance Logical:实际没有,但将来会钻孔的地方 根据clearance的大小设定空旷区大小 Clear size.
IllSizedDrillDef ect
referenc e
Measuring shift
University
referenc e
no CELs found in the vicinity of the reference drill center
检测机理-孔层分析
6. 在孔破模式,测量 孔破角度( break angle). 当角度 大于设定的孔破角度时报告孔破.
检测机理-孔层分析
Customer Training
测孔流程:
1.确认实际孔的位置,如果相应位置上没有, 则报少孔。

odyssey仪器操作简单流程

odyssey仪器操作简单流程

Odyssey仪器的操作流程:1.在面板上打开仪器电源开关,再开启电脑,关机时相反。

2.用软布或无尘纸蘸双蒸水将扫描平面的玻璃擦拭干净。

3.将要扫描的胶或膜放到扫描平面上,记下坐标,扣上舱盖。

4.双击软件图标,输入用户名、密码,进入主菜单。

5.点击scan快捷键,选择要扫描的区域、介质、通道及合适的灵敏度、分辨率,开始扫描。

6.扫描结束后对扫描结果进行分析。

7.依次进行图象裁切、定道、定分子量标准、背景扣除等操作。

8.根据需要输出图形或数据报告表格。

Odyssey软件的操作流程:1. 打开软件,点击“File”栏中的“New”创建一个新项目(如果是在已有项目中添加新内容,则点击“File”栏中的“Open”,打开已有项目)2. 在窗口“New Project”中设定项目文件存储的路径和项目名称3. 点击“Scan”按钮创建该新项目4. 在登陆窗口输入用户名和密码5. 点击“OK”按钮,进入扫描控制窗口6. 在“Name”栏输入该次扫描的名称7. 在“Group”栏选择用户所属的组8. 在“Preset”栏选择目前进行扫描的介质9. 选择合适的分辨率,扫描质量和焦距(对于膜来说,一般选择分辨率为169,扫描质量为medium,焦距为0,假如是胶,焦距为胶厚度的1/2)10. 在“Channels”栏根据所用二抗标记的荧光选择合适的通道,700或800或两者皆选,每个通道的激光强度可分别在“Intensity”栏调节11. 扫描控制窗口的右下侧矩形框为扫描区域,根据待扫描的膜的位置调节红色矩形框,使其将膜的区域完全覆盖(注意:膜或胶一般均放置在扫描平面的左下方)。

12. 扣上舱盖开始扫描13. 点击“Alter Intensity”按钮可以根据需要分别调节两个通道的亮度,对比度和灵敏度,调节好后点击“OK”按钮确认14. 扫描结束后,图片会自动弹出,保存扫描图片。

做Western blot仪器Odyssey

做Western blot仪器Odyssey

In-Cell Western Assay
In-Cell Western 工作流程
细胞培养 Culture cells to confluency in 96-well or 384-well plates 处理细胞 Treat cells (inhibitor, stimulator, etc…)
Odyssey VS ECL流程
ECL Odyssey
跑胶
转膜 封闭 结合一抗、洗涤 结合红外染料标记二 抗、洗涤,成像
1
2 3 4 5 6
跑胶
转膜 封闭 结合一抗、洗涤 结合酶标记二抗、 洗涤 发光试剂盒 暗房曝光成像
7
荧光直接检测
●信号持久 ●不需要底物 ●不需要底片/暗室
INFRARED APD DETECTOR ON-SCREEN Display
Incubate with IRDye® secondary antibodies (e.g.: IRDye® 680 and IRDye® 800CW)
Incubate with IRDye® secondary antibody and a DNA stain (e.g.: To-Pro-3)
Odyssey系统扫描 Scan plate directly and analyze on the LI-COR Infrared Imaging Systems.
固定细胞 Fix cells (3.7%formaldehyde, methanol or Prefer)
透化细胞 Permeabilize cells (0.1%Triton-X 100)
Incubate with 2 primary antibodies
Incubate with 1 primary antibody

核医学仪器专题培训培训课件

核医学仪器专题培训培训课件
•接着是第三次循环、第四次循环……。
核医学仪器专题培训
27
五、图像的衰减校正
为什么要进行衰减校正?
•显像用放射性核素γ射线的能量主要在80~500keV之间 •人体组织的衰减(Attenuation)对投影值有较大影响。 •SPECT断层重建算法忽略了组织对γ射线的衰减作用,使图
像定量不准,出现伪影。 •图像衰减校正(Attenuation Correction,AC)是解决人体衰减的主要方法。
衰减校正方法
•在探头的对侧设置放射源,利用放射源发射出的γ射线由患者体外穿透 人体,在SPECT探头上成像。 •在同一台SPECT上同时获得透射(transmission)图像和发射(emission)图 像,从透射图像求得被显像部位的三维衰减系数分布图,对发射型断层 图像进行衰减校正。
•目前,SPECT/CT可采用X线进行图像衰减校正。
主要功能为数据采集。
核医学仪器专题培训
33
(1)探测器环
若干个晶体排列而成,是决定PET性能的最重要部分。 探头晶体的材料不同,接收光子并转化为可见光的性能也有差异。 晶体主要有:
锗酸铋(bismuth germinate,BGO) 硅酸钆(gadolinium orthosillicate,GSO) 硅酸镥(lutetium oxyorthosillicate,LSO) LYSO等。 临床型PET(C-PET)采用NaI(Tl)晶体,但现在已经趋于淘汰。
5.井型计数器校准(well counter calibration)
核医学仪器专题培训
43
(七)PET的性能评价
评价标准
美国电器制造商协会(National Electric Manufacturers Association, NENA)于1994年制定了PET性能评价标准及测试方法NEMA NU 2-199 4,2001年对其进行了更新,更新后版本为NEMA NU 2-2001。

Odyssey红外荧光扫描成像系统的特点及应用

Odyssey红外荧光扫描成像系统的特点及应用

O ys 红 外荧 光 扫 描 成 像 系 统 (n a dIai yt ds y e Ifr g gSs m) re m n e
技 术 系 统 :相 对 于 传 统 化 学 显 色 法 ( D B 显色 ) 化学 发 光 如 A 、 法 ( E L 等 , ds y 较 大 改 进 。 如 C ) O ys 有 e
溶液 、 阴性对照样 品溶 液各 l , 0 分别 注入液相色谱仪 , 行 进 测定 。结果供试品 色谱 中, 与对照 品色谱 相应 的位置 上 , 在 有相 同保 留时间的色谱峰 , 而阴性对 照样品溶 液在 此保 留时
间无 干 扰 。因 此 可 在 此 系 统 条 件 下 对 黄 连 进 行 定 量 分 析 。 2 6 线 性 关 系考 察 . 精 密 吸取 0 24 gm 的盐 酸 小 檗 碱 .08m / l 对 照 品溶 液 1234 5m , 别 置 l J 瓶 中 , 甲 醇 稀 释 、、、 、 l分 0r 量 n 加 至刻 度 , 匀 , 得 。制 得 0004 gm 、 .4 6m / l0 摇 即 .2 8m /J0 OO9 gm 、 .
各 l , 0 按上述色谱条件实验 , 测定峰面积 , 以外标法计算供
试 品溶 液 中 盐 酸 小 檗 碱 的 含 量 。通 过计 算 , 号 000 批 753的一
清颗粒的盐酸小檗碱含量为 2 86r /; 号 00 1 .1 g 批 a g 7 85的颗 粒
的 含 量 为 26 gg ̄ 号 002 的 颗 粒 含 量 为 2 8 gg .7m / ; 7 91 .0m /。
l , 0 进样分析 2 , 次 记录色谱 图, 计算盐 酸小檗碱 回收率 为
10 0 % ,S 0 .9 R D为 0 3 % 。结 果 见 表 1 . 9 。

Odyssey CLX 操作指南1

Odyssey CLX 操作指南1
软件安装 ..................................................................................................................................... 4 Windows 7,XP ,vista 系统........................................................................................... 4
导入图片 ........................................................................................................................... 18 泳道设置 ........................................................................................................................... 19 设定 Marker....................................................................................................................... 20 创建新 marker ................................................................................................................... 20 自动识别条带 ................................................................................................................... 21 手动编辑条带 ................................................................................................................... 21 单通道信号归一化 ..............................................................................................................21 查看表格 ........................................................................................................................... 22

近红外双色激光成像系统

近红外双色激光成像系统
旋转图像 ......................................................................................................................................11 裁剪图像 ......................................................................................................................................12 打开图像查看 ......................................................................................................15
Odyssey
近红外双色激光成像系统
软件操作指南 (中文版)
基因有限公司 2007 年 3 月
Odyssey 软件操作指南
目录
第 1 章 序言............................................................................................................................................1
中心特征 ......................................................................................................................................18 大小特征 ......................................................................................................................................18 标准品的命名 ..............................................................................................................................18 输入标准品的浓度 ......................................................................................................................19 采用标准品进行定量 .......................................................................................................................20 对未知样品定量 ...............................................................................................................................21 700 通道图形的定量 ........................................................................................................................22 使用细节观测进行数据比较 ...........................................................................................................24 打印定量报告 ...................................................................................................................................24 报告模板 ......................................................................................................................................24

Scout II 系列红外成像仪操作手册说明书

Scout II 系列红外成像仪操作手册说明书

Scout II®Series Thermal Imager Operator’s Manual© 2015 FLIR Systems, Inc. All rights reserved worldwide. No parts of this manual, in whole or in part, may be copied, photocopied, translated, or transmitted by any electronic medium or in machine readable form without the prior written permission of FLIR Systems, Inc.Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems, Inc. and/or its subsidiaries. All other trademarks, trade names, or company names referenced herein are used for identification only and are the property of their respective owners.This product is protected by patents, design patents, patents pending, or design patents pending.If you have questions that are not covered in this manual, or need service, contact FLIR Systems, Inc. customer support at 805.964.9797 for additional information prior to returning a camera.This documentation is subject to change without notice.Proper Disposal of Electrical and Electronic Equipment (EEE)The European Union (EU) has enacted Waste Electrical and Electronic Equipment Directive 2002/96/EC (WEEE), which aims to prevent EEE waste from arising; to encourage reuse, recycling, andrecovery of EEE waste; and to promote environmental responsibility.In accordance with these regulations, all EEE products labeled with the “crossed out wheeled bin”either on the product itself or in the product literature must not be disposed of in regular rubbish bins, mixed with regular household or other commercial waste, or by other regular municipal waste collection means. Instead, and in order to prevent possible harm to the environment or human health, all EEE products (including any cables that came with the product) should be responsibly discarded or recycled.To identify a responsible disposal method where you live, please contact your local waste collection or recycling service, your original place of purchase or product supplier, or the responsible government authority in your area. Business users should contact their supplier or refer to their purchase contract.Important Instructions and Notices to the User:Modification of this device without the express authorization of FLIR Commercial Systems, Inc. may void the user’s authority under FCC rules to operate this device.Note 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna;• Increase the separation between the equipment and receiver;• Connect the equipment into an outlet on a circuit different from that of the receiver; and/or• Consult the dealer or an experienced radio/television technician for help.Industry Canada Notice:This Class B digital apparatus complies with Canadian ICES-003.Avis d’Industrie Canada:Cet appareil numérique de la classe B est conforme à la norme NMB-003 du CanadaFLIR Systems, Inc.Table of ContentsIntroduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Scout II Series Camera Features. . . . . . . . . . . . . . . . . . . . . . 5 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Charging the Camera. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Using USB/Analog Video Adapter Cable—Scout II 320 only8Scout II Series Power Management . . . . . . . . . . . . . . . . . . . 8Scout II/LS-X/LS-XR/Ocean Scout End User Tool. . . . . . . . 9 Operating Your Scout II Series Camera . . . . . . . . . . . . . . . . . . 10 Camera Features and Controls . . . . . . . . . . . . . . . . . . . . . . 10Buttons and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Auto Shutdown Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Scout II Series Model Features . . . . . . . . . . . . . . . . . . . . . . 13Important Safety Instructions•DO NOT DISASSEMBLE THE DEVICE.•Read and follow all instructions•Heed all warnings•Only use the attachments/accessories specified by themanufacturer•All service must be provided by the manufacturer Battery Safety InformationThe Scout II Series camera is a sealed unit with sensitive electronics and contains no user-serviceable parts. Service or repair is to be performed only by the manufacturer. The camera unit must not be opened or modified by the user or owner in any manner or for any reason.The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not disassemble the camera, store above 60°C, or incinerate. The battery is factory replaceable only; return the camera to the manufacturer for battery replacement.1Introduction1IntroductionFLIR’s Scout II Series thermal handheld cameras give hikers, hunters, and outdoorsmen the abilityto see clearly in total darkness, providing a wealth of information during any nighttime excursion.The Scout II Series camera enables the outdoorsman to:•See animals and difficult terrain in reduced visibility or total darkness•See through smoke, dust, and light fog•See camouflage and foliage in any lighting conditions•See more—and see farther—than with low-light night vision gogglesThe Scout II Series camera makes images from heat, not light, a feat impossible for the naked eyeor even image intensified (I2) night vision devices, which means you can see clearly even withoutany visible light at all. People, animals, and objects all make their own heat and their own contrast,and are clearly seen by the Scout II Series camera in even the most adverse conditions.Visible ImageScout II Series Camera Image1Introduction1–1Scout II Series Camera Features•Rugged design—Built to withstand the demands of outdoor use.•Microbolometer sensor for excellent image quality and clarity•336×256 pixel resolution, 17° horizontal field of view—Scout II 320•240×180 pixel resolution, 24° horizontal field of view—Scout II 240•Palm-Sized Portability and Light Weight—Only 12 Ounces•Embedded LED T ask Light•USB Cable for battery charging•USB/Video Adapter Cable for video out—Scout II 320 only.•Rechargeable Internal Li-Ion battery—Provides up to 5 hours of camera operation on asingle chargeCaution!Do not disassemble the camera enclosure. Disassembly can cause permanent damageand will void the warranty.Do not point the camera directly at extremely high-intensity radiation sources, such asthe sun, lasers, arc welders, etc.Be careful not to leave fingerprints on the camera’s infrared optics. Clean only with lowpressure fresh water and a lens cloth.2G etting Started2Getting StartedThe Scout II Series camera is available with the features, options, and accessories described in this manual.Refer to the packing list enclosed with your camera shipment to determine the actual contents of your camera package.In addition to the camera and Quick Start card; the following items are included in the camera package:The following optional accessories are available for the Scout II Series cameras.USB CableWristLensUSB/Video AdapterCoverStrapCable—Scout II 320 onlyMolle-CompatibleBelt Holster USB Power Adapter SetFloating LanyardCamera Carrying Pouch2–1Charging the CameraCaution!The camera battery should be fully charged prior to use. To charge the camera, lift the cover from the USB port, plug in the USB cable provided with the camera, and plug other cable end into a USB power source.•When charging correctly, the charging indicator will be lit orange.•When fully charged, the charging indicator will light solid green. The initial charge time is approximately 5 hours.To assure proper charging, Scout II Series cameras should be turned OFF throughout the charging cycle. Charging MUST only be done when the camera temperature is from 0 to 40°C (32 to 104°F), or battery damage may B portPlug in USB Charger Charging indicator greenCharging indicatorwhen fully chargedorange when charging2–2Using USB/Analog Video Adapter Cable—Scout II 320 onlyTo obtain analog video out, insert the adapter cable into the USB connector. The camera will detect the adapter cable and provide the video stream. Use an RCA cable to connect to a monitor or a video recorder.When using the USB/Analog Video Adapter cable to record video or supply video to a remote monitor, it may be useful to turn off the Auto Shutdown feature of the camera.2–3Scout II Series Power ManagementY our Scout II Series camera is equipped with a power management system that provides up to five hours of continuous operation. When left in the Off state the battery will hold a charge for up to two months. To make the best use of the camera it is important to understand the basic power states of the camera.•When the camera is turned on from the Off state, it takes about five seconds to become operational. During the Bootup process, the FLIR splash screen is shown and then the software version is displayed briefly. Pressing the Power button will toggle the camera between On and Off.•The camera shuts down after about five minutes if no buttons are pushed. Auto shutdown 30s , is shown in the display, and after counting down for 30 seconds the camera will shutdown.Camera StateHow do you know?OffThe display is off and the T ask Light comes on when the Brightness button is pressed.On The display is on and the LED T ask Light is disabled. If the image appears blank, make sure the lens cover is removed.USB/VideoCustomer suppliedadapter cableRCA cable2–4Scout II/LS-X/LS-XR/Ocean Scout End User ToolThe Scout II/LS-X/LS-XR/Ocean Scout end user tool is a graphical user interface (GUI) that is used with the following FLIR handheld thermal imaging cameras:•Scout II Series•LS Series•Ocean ScoutThese cameras are similar in design and may be referred to generally as “Cayman” cameras. The software allows a user to make minorconfiguration changes to one of thesecameras. For example, a user can turncamera sounds on or off, or change theamount of time before the camera shutsdown automatically. The tool can also beused to perform a camera firmwareupgrade if one becomes available in thefuture.To download the GUI, go to http://id=53129, select the end user toolunder Software to download.Select Configuration to read camerasetting and make changes to availablecamera features.3Operating Y our Scout II Series Camera3Operating Your Scout II Series Camera3–1Camera Features and Controls3–2Buttons and ControlsPower ButtonTurn the camera On and Off.Display Brightness ButtonUse this button to cycle through the five levels of display brightness. Each press of the button advances to the next level of brightness.When the highest brightness level is reached, subsequent button presses advance to the next lower brightness levels. When the lowest brightness level is reached, subsequent button presses advance to the next higher brightness level. One of the following icons is displayed for approximately 3 seconds after the button is pressed indicating the current brightness level:NoteWhen the Scout II Series camera is powered Off, the Display Brightness button, when held on, turns on the LED Task Light.Power2× zoom/White hot/Display Brightness/EyepieceAdjustable LED Task Light USB/Charging/Analog video out of USB port (Scout II 320 only)(Task Light On/Offwhen Camera is off)Freeze Frame DiopterBlack hot/Instalert HighestLowestWhite Hot/Black Hot/InstAlert™ ButtonUse this button to toggle between the two video and the four InstAlert™ colorpalettes. In the default White Hot palette, hotter objects appear as white or light grey.In Black Hot, hotter objects appear as black or dark grey. In the InstAlert™ palettesthe hottest objects in the scene are highlighted in red to simplify detection ofanimals, people, and objects. There are four pre-set levels of InstAlert™ that you can select based on the specific scene being viewed. All of the InstAlert™ palettes are based on the white hot palette.While white hot is the most commonly used and visually intuitive method of viewing thermal imagery; black hot can often enhance contrast of certain objects or provide better visual perspective in some conditions. When switching between palettes, the appropriate icon is displayed for approximately 3 seconds.Zoom Button—Scout II 320 onlyUse this button to switch the camera between no zoom (full resolution) and 2×zoom. The central part of the image is magnified twice its normal size when 2× isselected.When zoom has been selected the icon is continuously shown in the display:Freeze Frame Button—Scout II 240 onlyUse this button to freeze the video so that a single frame may be inspectedclosely.Diopter ControlsThe diopter adjustment lever allows you to adjust for optimum image sharpness in the eyepiece. When the diopter adjustment lever is pointing straight away from the front of the camera, it is in the neutral position. Adjust the diopter setting for the sharpest image in the viewfinder.Black hotWhite hot InstAlert™ 1 – 4Adjustable Diopterneutral position3–3BatteryY our Scout II Series camera is equipped with a sophisticated power system using a rechargeable internal Li-Ion battery.Battery Status IndicatorWhile the camera is On, a battery status indicator is always shown in the corner of the display image. This indicator provides an estimation of the remaining battery charge. 3–4Auto Shutdown OperationAuto Shutdown is a feature of the Scout II Series camera that helps to guard against draining the battery prematurely by inadvertently leaving the camera on.Auto Shutdown turns the camera off if the following conditions are met:•The camera is On•No buttons have been pressed for about five minutes.Once these conditions are met you will see the following message in the display: Auto shutdown 30s , and after counting down for 30 seconds the camera will shutdown.Press any button during this countdown to terminate Auto Shutdown and resume normal operation. NotePressing any button during an Auto Shutdown countdown will only terminate the countdown and abort the shutdown. The normal function of the button will not occur.full charge half chargeplugged in4T echnical Data4Technical Data4–1Scout II Series Model FeaturesPowerScout Model Scout II 240Scout II Series Handheld Thermal Camera with video resolution of 240 × 180 pixels with freeze frame capability.Scout II 320Scout II Series Handheld Thermal Camera with video resolution of 336 × 256 pixels with 2× digital electronic zoom.Included with all camera modelsLens Cover, USB Cable, Wrist Strap, Operator’s Manual, and Soft Carrying Pouch FeatureStart up< 5 seconds Thermal Sensitivity,Waveband< 50 mK @ f/1.0,7.5 µm to 13.5 µm Detector T ypeVOx Microbolometer Scout II 240—240 x 180 pixels Scout II 320—336 x 256 pixels Resolution / Display640x480 pixels LCD Scout II 240, < 9Hz Refresh rate;Scout II 320, < 9Hz Refresh rate Video OutputNTSC/PAL switchable using GUI available from FLIR website. (Scout II 320 models only—Composite video out through USB port via USB/Video Adapter Cable to customer supplied RCA cable.)Image ProcessingFLIR Proprietary Digital Detail Enhancement Focus, ZoomFixed focus (Scout II 320 models only—2x electronic zoom)Display PalettesWhite Hot, Black Hot, InstAlert ™; selectable T ask LightLED enabled during power off stateBattery T ypeInternal Li-Ion Battery Life Operating Greater than 5 Hours at 25°C4Technical DataEnvironmentalPhysicalField of View Range Detection1Scout II 240 and Scout II 320Camera OperationalTemp.-4°F to 122°F (-20°C to 50°C)Storage Temp.-40°F to 140°F(-40°C to 60°C)Ingress Protection Rating IP-67, submersible up to 1 meterDrop Test Rating 1 meter dropScout II 240, Scout II 320Weight, including lens12 oz. (340 g)Size (L × W × H) 6.70” × 2.31” × 2.44”(172 × 58.7 × 62 mm)Scout II 240, Scout II 320Field of View (FoV)Scout II 240: 24° × 18° NTSCScout II 320: 17° × 13° NTSCDetect Man (1.8 m × 0.5 m)Scout II 240383 yd. (350 m)Scout II 320600 yd. (550 m)1.Actual range may vary depending on camera set-up, environmental conditions, and userexperience.。

Odyssey红外荧光扫描成像系统的特点及应用

Odyssey红外荧光扫描成像系统的特点及应用

Odyssey红外荧光扫描成像系统的特点及应用【关键词】红外荧光扫描成像系统 Western印迹法Odyssey红外荧光扫描成像系统(Infrared Imaging System)是一套具有高灵敏度的实验系统,在医院、科研院所中得到越来越多的应用,日益受到人们的关注和青睐。

现将Odyssey工作原理与技术特点、应用范围、操作流程、常见问题及解决策略等介绍如下。

1 Odyssey工作原理与技术特点Odyssey是通过在二抗上标记荧光染料,再通过固定波长激光激发后,采集染料发出荧光信号来确定目的蛋白含量的技术系统。

相对于传统化学显色法(如DAB显色)、化学发光法(如ECL)等,Odyssey有较大改进。

Odyssey系统可直接在膜、凝胶和微孔塑料板中对样品进行检测,该系统采用2个红外激光作为激发光,波长分别为680 nm和780 nm,检测则配置2个720 nm和820 nm波长高灵敏度二极管。

Odyssey优于传统方法的主要特点是高灵敏度。

一般荧光染料激发和检测波长都在可见光谱区,在此范围内膜、凝胶和微孔塑料板也会发出荧光,容易产生高背景荧光干扰,影响实验结果,而Odyssey采用红外波长区,此时大分子物质几乎不发出任何荧光,在检测中背景荧光很低,从而有较好信噪比。

Odyssey另一特点是直接检测,可同时检测两种IRDyes染料的荧光信号。

IRDyes染料最大吸收值与Odyssey两个激发波长相匹配,其发射波长又与Odyssey两个检测波长相匹配,同时发射波长峰值相隔100 nm,这使Odyssey有较大灵敏度和较小信号交叉。

Odyssey系统检测不需要曝光和底物显色,也不需要X光片,操作简便,另外配有功能全面的软件支持,结果分析如生物大分子分子量确定、定量及图像处理也很容易。

Odyssey系统操作简单,双色检测,可一次同时检测两种目的分子,这样更直观、更省时。

由于采用二极管激光器和固态检测器,Odyssey具有更长使用寿命,且维护要求也低。

Odyssey红外激光成像系统 —蛋白研究的多功能平台[知识荟萃]

Odyssey红外激光成像系统 —蛋白研究的多功能平台[知识荟萃]

红外荧光 VS 化学发光
成像效果
Odyssey 曝光30秒 曝光1分钟 曝光5分钟 曝光10分钟
红外+荧光 DEMO
实验目的 检测培养细胞转染外源基因的表达状况
实验步骤
Odyssey: 膜+一抗孵育+荧光标记抗体孵育+Odyssey扫描成像 ECL: 膜+一抗孵育+酶联二抗孵育+底物显色+ UVP扫描成像
DETECTOR
INFRARED LASER DIODE
Antigen on membrane
Primary antibody binds to antigen
IRDye labeled secondary antibody binds to primary
antibody
荧光-准确定量
CHEMILUMINESCENCE • 动态信号-信号随时间变化 • 信号不与目标蛋白浓度成比例关系
Saturation
ODYSSEY • 静态信号-信号不随时间变化 • 信号和目标蛋白浓度成比例关系
INTENSITY
Background 0,0
TIME
High concentration / signal
0,0
Medium concentration / signal
TIME
Low concentration / signal
* Two-color detection requires primary antibodies from different hosts
双色-ERK蛋白的磷酸化
Anti-EGFR and anti-phospho-EGFR antibody specificity in A431 cells

蔡司场发射扫描电镜操作培训

蔡司场发射扫描电镜操作培训
连续中心点: 激活此功能
后,屏幕上出现一个十字
座标。拖动十字座标到感
兴趣点,点击鼠标左键。
感兴趣点将自动移到屏幕
中心。
操作软件简介
样品台导航器: 显
示样品座的位置和
一些参数。请注意:
这只代表样品座的
位置。不是样品的
位置。
操作电镜的基本流程
• 将样品放入样品室, 抽真空(抽真空时手推紧一下仓门)
。真空度达到5.00e-005mbar以下时, 可打开设定的高压, 取
操作电镜的基本流程
样品台控制器:
当1号操纵杆上下移动,控制样品台上下移动。
当1号操纵杆左右移动,控制样品台左右倾斜。
当2号操纵杆上下左右移动,控制样品台前后左
右移动。
当旋拧2号操纵杆,控制样品台顺时或逆时旋转

操作电镜的基本流程
图片保存: 当图片冻结后,鼠标移动到图片上,点击鼠标右键后, 选择Send
• SEM Control: Scan 面板
选择图像存储的
分辨率
扫描速度
图像的冻结是以手动
形式还是扫完整幅图
片后
积分次数或者是
平均次数
图像噪音去除的六种方
式选择: 帧平均,帧积
分,线平均,线积分,
像素平均,连续平均。
操作软件简介
• SEM Control: Stage界面
样品台目前所在的位

激活此处: 样品台泄真空时
循环机给机器降温散
热量很大, 所以隔间门
要打开, 不得关闭, 尤
其在夏天, 否则水循环
机负荷太大会损坏。
操作软件简介说明
• Smart软件的启动
• 双击桌面上的快捷键 或者在开始菜单中

红外相机监测培训方案

红外相机监测培训方案

红外相机监测培训方案一、培训背景随着科技的不断发展,红外相机作为一种重要的监测工具在各个领域得到了广泛应用。

为了提高红外相机的有效使用率和监测效果,有必要对使用人员进行专门的培训,以提高其红外相机的使用技能和操作能力。

二、培训目的本次培训旨在使学员了解红外相机的基本原理、操作方法和应用领域,掌握红外相机的调试和故障排除技巧,提高在实际工作中的应用能力。

三、培训内容1. 红外相机基础知识- 红外辐射原理- 红外相机的构造和工作原理- 红外图像的特点和解读方法2. 红外相机的操作技巧- 红外相机的开机和关机步骤- 红外图像的拍摄和保存- 红外相机参数的设置和调整3. 红外相机在不同领域的应用- 建筑检测与维护- 电力设备巡检- 石油化工设备监测- 安防监控4. 红外相机的故障排除- 常见故障及解决方法- 红外相机维护保养5. 红外相机的案例分析- 红外相机在各个行业的典型应用案例分析- 案例分析的方法和步骤四、培训方式1. 理论讲授通过专业讲师的讲解,学员将了解红外相机的基本知识和操作技巧。

讲师将结合实际案例和图像展示,使学员更好地理解和掌握相关知识。

2. 实践操作通过实际操作红外相机,学员将亲自体验红外相机的使用过程,掌握相关操作技巧,并通过实际案例分析,提高解决问题的能力。

3. 案例分析通过分析典型案例,学员将学习如何运用红外相机进行故障排除和监测,提高应用能力和工作效率。

五、培训时间和地点本次培训预计为期两天,具体时间和地点将根据实际情况确定。

培训地点将提供实际使用红外相机的场景,以便学员更好地进行实践操作和案例分析。

六、培训评估为了评估学员的学习效果和掌握程度,将进行培训结束后的考核。

考核内容包括理论知识测试、实践操作和案例分析。

考核成绩将作为培训效果的重要参考。

七、培训证书培训结束后,将根据学员的考核成绩颁发相应的培训证书,以证明其已完成本次培训并具备相应的红外相机使用能力。

八、总结红外相机作为一种重要的监测工具,其应用领域广泛且前景广阔。

licor odyssey 红外荧光扫描成像

licor odyssey 红外荧光扫描成像

一. Odyssey红外成像系统技术特点一般的荧光染料的激发和检测波长都位于可见光谱区,在此波长范围内,化学高分子物质(膜、胶、微孔塑料板等)也会发出荧光,因此易产生高背景的荧光干扰,从而不能有效用于膜上蛋白或者核酸的直接荧光成像。

而在红外波长区这些大分子物质几乎不发出任何荧光信号,使得红外荧光染料在长波下检测时背景荧光很低,具有很好的信噪比,这一特点使得核酸和蛋白的膜上荧光检测成为可能。

LI-COR根据红外荧光的这一特点开发出Odyssey红外成像系统,独特的采用2个红外激光作为激发光源,以扫描成像方式对样品进行检测。

样品载体可以是膜、凝胶和微孔板。

该系统配置的2个红外激光激发光源,激发光波长分别为680nm和780nm,配置的2个高灵敏度光敏二极管可以分别检测720nm和820nm 的发射荧光,因而Odyssey可同时检测两种IRDyes染料的荧光信号。

IRDyes染料的最大吸收值与Odyssey的两个红外激光器680nm和780nm激发波长相匹配,其发射光波长又与Odyssey的两个光敏二极管检测波长相匹配,与同时IRDye700和IRDye800的发射波长峰值相隔100nm,因此Odyssey可以给出最大的灵敏度和最小的信号交叉。

同时由于采用二极管激光器和固态检测器,Odyssey具有很长的使用寿命(激光器使用寿命约4-6万小时),而系统维护的要求却很低。

该系统可广泛应用于信号传导,蛋白磷酸化分析,In-Cell-Western分析等蛋白领域研究。

主要特点1.高灵敏度,效果同于或者好于化学发光法,但不需信号放大步骤,信噪比高。

2.直接检测,无需曝光和显色底物,不需要X光片,不需要暗房,没有放射性废料产生。

3.双色检测,可以在一次杂交中同时检测两种目的分子,直观,省时。

4.宽广的线性范围,可用于高准确性定量。

5.背景低,图像清晰,激光强度可调,不会丢失弱的信号6.强有力的软件支持,结果分析如确定分子量和定量及图象处理编辑很容易7.系统操作和维护简单Odyssey的应用应用领域:蛋白质研究,核酸研究具体包括:Western分析,In-Gel Western分析,蛋白质定量分析,双色磷酸化分析,考马司亮兰胶的扫描,蛋白双向电泳,双色 EMSA,双色微孔板分析,BD PowerBlot Analysis,Northern Blot,Southern Blot等二.系统安装条件1.位置要求:稳定水平的操作平台放置设备,远离热源,避免阳光直射2.空间及载重要求:操作平台尺寸(长×宽×高):80×70×80cm操作平台载重:40kg3.温度要求:15-25℃4.湿度要求:不超过60%5.电源:90-250V AC,47-63Hz。

OdysseyCLX操作指南1.pdf

OdysseyCLX操作指南1.pdf
Odyssey CLx 近红外双色荧光成像系统
Odyssey CLx 近红外双色荧光成像系统
Odyssey CLx Image Studio 3.1 操作指南
基因有限公司 2013 年 9 月
目录
Odyssey CLx 近红外双色荧光成像系统
序言
亲爱的用户,您好:
非常感谢您选购基因有限公司代理的美国 LICOR 公司 Odyssey 双色红外激 光成像系统,我们将竭诚为您提供优质的售后服务。为了您能更好地了解、使 用仪器及相应软件,我们特编辑此 Odyssey 用户手册,本手册包括:odyssey 快 速操作指南,软件操作 指南,western blot protocol,odyssey 抗体选购指 南,odyssey 检测 western blot 实验小贴士等内容。
Odyssey CLx Image Studio 3.1 ......................................................................................................... 3 第一章:入门指南 ................................................................................................................................. 4
在仪器使用中及抗体选择方面有任何问题、疑问,请您及时和我们联系。
本手册系由原版英文说明书编译而来,希望它能为您提供帮助。可能存在 的错误和遗漏,如与英文说明书发生冲外双色荧光成像系统
目录
Odyssey CLx Image Studio 快速操作指南 .................................................................................... 1 打开 Image Studio 软件............................................................................................................ 1 如何创建一个新的工作区域: .................................................................................................... 1 将膜放在 Odyssey CLx 仪器的成像面板上 .............................................................................. 1 打开 Acquire 图标 .................................................................................................................... 1 导出采集好的图片 ........................................................................................................................2 导出一张用于打印的图片.....................................................................错误!未定义书签。 导出一张用于打印的图片 ............................................................................................................2

红外乳腺诊断仪培训资料

红外乳腺诊断仪培训资料

第一章红外乳腺诊断仪的仪器组成1.原理框图发射红外线摄取图像图像处理2.诊断原理红外线乳腺诊断仪主要是通过红外探头发射红外线穿透乳房,由于不同的组织对红外光的吸收程度不同,如:癌可优先吸收红外光,而良性病变吸收红外光较少,故恶性区比良性区吸收更多的红外线,通过高灵敏度的摄像机呈现在荧光屏上的图像也不相同,因此根据图像的异同来诊断疾病。

第二章红外乳腺诊断仪的使用第一节使用环境电脑彩色乳腺诊断仪属精密电子仪器,价格较贵,为了提高诊断率、延长仪器的使用寿命,对使用环境要求如下:1、光线:此检查是用光源探头对乳腺组织进行透视扫描,经过图像处理显示的屏幕上。

检查应在暗室中进行。

室内光线太强时,乳腺表面的光线将透进乳腺的部分光线抵消,从而不能有效地显示灰影,尤其可以掩盖浅灰影,而且太强的光线也可干扰视觉对屏幕的观察。

但是,室内光线太暗时,对操作不利,所以,可以让少量光线进入室内,以便操作及其它活动。

2、清洁:室内空气中尘埃过多,落入机内,日久会造成电气事故,损坏仪器。

所以,室内应适量减少流动人数,清洁地面勿干扫,最好用吸尘器。

因湿扫可增加室内湿度,对仪器也不利。

3、温度:电脑彩色乳腺诊断仪的使用环境温度在10-40℃,但是,由于受检者在检查时暴露较多,温度太低易造成受凉,而室温超过30℃时,又会使人感到闷热、易出汗,不利检查。

所以,诊断室的温度以30℃左右为宜。

最好能装置空调。

4、湿度:乳腺诊断室湿度不应超过80%(相对湿度),否则会降低仪器零部件、元件的绝缘电阻,对电压很高的部件甚至会造成危险;高湿还会引起仪器金属部分的锈蚀,加速仪器损坏。

5、供电:乳腺诊断仪的工作电压为220V±10%,电源电压不应波动过大,控制在使用电压的±5%范围为最好,不能超过±10%,否则会严重影响仪器的工作性能,甚至会烧坏仪器。

因此,必须配备功率适当的交流稳压器,并且在同一线路上应避免大功率电器,否则当大功率电器开关时,会影响仪器的图像。

TOSOH AIA system 培训资料(六)

TOSOH AIA system 培训资料(六)

T O S O H A I A s y s t e m培训资料编著:练子富2006/3/10上海蓝怡科技有限公司目录第一章荧光免疫检测技术原理1.1 荧光现象1.2 荧光效率1.3荧光的猝灭1.4荧光物质1.5免疫标记法第二章AIA试剂2.1AIA试剂的构成2.2AIA试剂的分类2.3AIA试剂的生产工艺2.4AIA 试剂的保存2.5AIA 试剂的临床的检验意义第三章AIA仪器3.1 AIA仪器的检测原理3.2 分光仪器的性能比较3.3 AIA-360仪器使用说明书3.4 AIA-600II仪器使用说明书3.5AIA-1800仪器使用说明书第四章AIA实验检测中常见的问题及注意事项第一章荧光免疫检测技术原理荧光免疫技术是标记免疫技术中发展最早的一种。

很早以来就有一些学者试图将抗体分子与一些示踪物质结合,利用抗原抗体反应进行组织或细胞内抗原物质的定位。

Coons等于1941年首次采用荧光素进行标记而获得成功。

这种以荧光物质标记抗体而进行抗原定位的技术称为荧光抗体技术(fluorescentantibodytechnique)。

荧光免疫法按反应体系及定量方法不同,还可进一步分做若干种。

与放射免疫法相比,荧光免疫法无放射性污染,并且大多操作简便,便于推广。

国外生产的TDM用试剂盒,有相当一部分即属于此类,并且还有专供TDM荧光偏振免疫分析用的自动分析仪生产。

由于一般荧光测定中的本底较高等问题,荧光免疫技术用于定量测定有一定困难。

近年来发展了几种特殊的荧光免疫测定,与酶免疫测定和放射免疫分析一样,在临床检验中应用。

1.1荧光现象荧光的产生一此化学物质能从外界吸收并储存能量(如光能、化学能等)而进入激发态,当其从激发态再回复到基态时,过剩的能量可以电磁辐射的形式放射(即发光)。

荧光发射的特点是:可产生荧光的分子或原子在接受能量后即刻引起发光;而一旦停止供能,发光(荧光)现象也随之在瞬间内消失。

可以引起发荧光的能量种类很多,由光激发所引起的荧光称为致荧光。

Odyssey 红外荧光扫描成像系统培训手册

Odyssey 红外荧光扫描成像系统培训手册

Odyssey 红外荧光扫描成像系统培训手册二oo三 年 九 月目 录一、Odyssey红外成像系统技术特点二、系统安装条件三、Western实验所需试剂设备及样品四、培训程序及时间安排五、仪器及试剂系统介绍六、Western实验操作流程介绍七、软件使用培训八、常见问题处理九、注意事项一、Odyssey红外成像系统技术特点一般的荧光染料的激发和检测波长都位于可见光谱区,在此波长范围内,化学高分子物质(膜、胶、微孔塑料板等)也会发出荧光,因此易产生高背景的荧光干扰,从而不能有效用于膜上蛋白或者核酸的直接荧光成像。

而在红外波长区这些大分子物质几乎不发出任何荧光信号,使得红外荧光染料在长波下检测时背景荧光很低,具有很好的信噪比,这一特点使得核酸和蛋白的膜上荧光检测成为可能。

LI-COR根据红外荧光的这一特点开发出Odyssey红外成像系统,独特的采用2个红外激光作为激发光源,以扫描成像方式对样品进行检测。

样品载体可以是膜、凝胶和微孔板。

该系统配置的2个红外激光激发光源,激发光波长分别为680nm和780nm,配置的2个高灵敏度光敏二极管可以分别检测720nm和820nm 的发射荧光,因而Odyssey可同时检测两种IRDyes染料的荧光信号。

IRDyes染料的最大吸收值与Odyssey的两个红外激光器680nm和780nm激发波长相匹配,其发射光波长又与Odyssey的两个光敏二极管检测波长相匹配,与同时IRDye700和IRDye800的发射波长峰值相隔100nm,因此Odyssey可以给出最大的灵敏度和最小的信号交叉。

同时由于采用二极管激光器和固态检测器,Odyssey具有很长的使用寿命(激光器使用寿命约4-6万小时),而系统维护的要求却很低。

该系统可广泛应用于信号传导,蛋白磷酸化分析,In-Cell-Western分析等蛋白领域研究。

主要特点1.高灵敏度,效果同于或者好于化学发光法,但不需信号放大步骤,信噪比高。

红外培训手册1

红外培训手册1

付立叶红外光谱仪简易操作手册一、仪器准备打开光学台,预热仪器10分钟,光学台自动调整仪器完毕后→再打开计算机→进入红外光谱测定程序(方法:双击桌面上图标)。

二、背景的测定1、背景的准备将高纯度溴化钾在红外灯下干燥10分钟,取少量放入玛瑙研钵,仔细研磨均匀,直至成粉末状,将少量粉末装入压片机,加压,压力不可大于30MPa,否则将损坏模具,加压至25MPa,静候1min,取出锭片(厚度大概0.8mm),放入样品夹,进行背景扫描。

2、背景的扫描a. 设置背景扫描。

点击“采集”中的“实验设置”,如下图:b.设置背景扫描方式。

进入背景设置界面,选择“指定背景使用时间”,设置使用时间参数,根据自己所测样品时间设置,即在此时间内,背景有效,其余参数可不做变化,如图,点击确定。

背景扫描。

三、样品的测定 1、样品的准备a 、固体样品:取约150mg 干燥的KBr 和1~2mg 待测样品于玛瑙研钵中混合均匀,充分磨细,压成薄片。

b 、液体样品:取少量KBr 研磨,压成薄片后,在表面均匀滴上一滴待测样品。

2、样品的扫描a.将压好的样品放入红外仪,点击“样品扫描”可进行样品扫描,如下图。

b.更改谱图名称。

在对话框里输入文件名可更改谱图名称,然后点击“确定”,如图:更改谱图名称c.如下图红箭头标示,为样品采集状态:d.查看采集状态。

点击对话框中“是”将谱图加到window 1临时窗口查看谱图。

e.将透过率转化为吸光度。

点击“Abs”图标,可将谱图以吸光度表示。

f.校正基线。

点击“自动基线校正”图标,进行基线校正(此步骤只可在吸光度下进行)。

g.下图中,紫色谱图为基线调整前的图。

掉多余的谱图。

i.以透过率表示谱图。

点击“透过率”图标,将谱图装化为透过率,如下图:的效果。

k.根据谱图的具体情况,选择需要平滑的点数,点数越大,平滑的效果越好。

l.选中没用的谱图,将其删去。

m.标峰。

点击“标峰”——“替代”,可对谱图进行自动标峰,也可点击坐下角的“T”图标,进行手动标峰。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1. 仪器概况及相关应用讲座(1 小时) 2. 仪器使用培训(2 小时) 3. 用户实际操作练习与答疑(1 小时)
五、仪器及试剂系统介绍
1. Odyssey 红外成像系统技术特点讲解 2. 仪器系统组成和工作原理讲解 3. 配套试剂介绍
六. Western 实验操作流程介绍
荧光检测 Western 操作流程(以硝酸纤维素膜为例): 1. 吸去培养液,用预冷的 PBS 洗细胞两次 2. 加入细胞裂解液,4℃放置 20min 3. 用细胞铲刮下细胞,转移到 1.5ml 离心管,13000rpm,4℃,20min 4. 取上清 5. 取 20-100µg 蛋白进行电泳 6. 电泳:聚丙烯酰胺凝胶电泳(PAGE)按分子克隆实验手册操作 7. 硝酸纤维素膜于转移缓冲液(PBS)中平衡 20min。(如果使用 PVDF 膜,请先
一、Odyssey 红外成像系统技术特点
一般的荧光染料的激发和检测波长都位于可见光谱区,在此波长范围内,化 学高分子物质(膜、胶、微孔塑料板等)也会发出荧光,因此易产生高背景的荧 光干扰,从而不能有效用于膜上蛋白或者核酸的直接荧光成像。而在红外波长区 这些大分子物质几乎不发出任何荧光信号,使得红外荧光染料在长波下检测时背 景荧光很低,具有很好的信噪比,这一特点使得核酸和蛋白的膜上荧光检测成为 可能。LI-COR 根据红外荧光的这一特点开发出 Odyssey 红外成像系统,独特的 采用 2 个红外激光作为激发光源,以扫描成像方式对样品进行检测。样品载体可 以是膜、凝胶和微孔板。该系统配置的 2 个红外激光激发光源,激发光波长分别 为 680nm 和 780nm,配置的 2 个高灵敏度光敏二极管可以分别检测 720nm 和 820nm 的发射荧光,因而 Odyssey 可同时检测两种 IRDyes 染料的荧光信号。IRDyes 染 料的最大吸收值与 Odyssey 的两个红外激光器 680nm 和 780nm 激发波长相匹配, 其发射光波长又与 Odyssey 的两个光敏二极管检测波长相匹配,与同时 IRDye700 和 IRDye800 的发射波长峰值相隔 100nm,因此 Odyssey 可以给出最大的灵敏度 和最小的信号交叉。同时由于采用二极管激光器和固态检测器,Odyssey 具有很 长的使用寿命(激光器使用寿命约 4-6 万小时),而系统维护的要求却很低。该 系统可广泛应用于信号传导,蛋白磷酸化分析,In-Cell-Western 分析等蛋白领域 研究。
4 扫描点击 Start Scan 按钮,开始扫描
扫描开始后,扫描的图像可以实时出现,在右下角可以看到完成的百分数
5 图像调整 当扫描达到 100%后,扫描结束,弹出图像调整对话框
Flip:图像位置颠倒选项,可以将图像进行上下颠倒 Rotate:图像旋转选项,可对图像进行不同角度的旋转 Subtract:在原始图像截选取需要的范围 Crop:将选取的范围裁剪下来 Undo:返回上一步 Adjust Image:调整图像的色阶 Alter Image:调整图像的亮度和对比度 在图像调整完成后,点击进入图像分析界面
二、如何对图像进行灰度分析
双击
Scan 下 Analysis 图标,打开图像,可以进行分析。
1 图像调整工具栏:
快捷图标 新建一个 project 打开已经存在的 project 打印显示的图像 扫描,由扫描仪获得图像 导出显示的图像,选择图像的分辨率和格式,并选择相应路径进行保存 在已有的 Scan 下,再次添加新的 Analysis 显示选中的 Analysis 将已打开的图像,再次打开并平行窗口排列 图像放大 图像缩小 图像比例调整 去除或显示图像上的标注 对图像的亮度和对比度进行调整 对图像的的色阶进行调整 显示 700 通道图像或显示双通道图像 显示 800 通道图像 将图像转化为黑白色 显示彩色图像 显示图像设置参数 显示图像背景设置参数
(通用试剂详细配方请参照《分子克隆实验指南》)
其它配套设备: 1) 蛋白电泳仪
2) 脱色摇床 3) 转膜仪 4) 分子生物学实验室常用工具:
加样器,Tip 头,量筒,离心管,离心机,冰盒等。
四、培训程序及时间安排
(请至少安排 2 名实验室长期工作人员参加培训,方便以后有人员变动您也能进行仪器 内部培训。)
点击确定,保存文件。 3 点击工具栏中 图标,该图标在可以进行扫描时变为彩色状态
系统提示输入用户名和密码,一般情况下用户名和密码均为 user,点击 OK,弹 出扫描设置对话框,对扫描参数进行设置
Name:输入本次扫描的名称 Group:定义用户所归属的组别 Preset:设定选择扫描界面
可以根据实验的要求进行扫膜、扫蛋白胶、扫 DNA 胶、扫 96 孔板等选择操作 Resolution:扫描分辨率设定,在右侧下拉框里选择需要的分辨率,有 21、42、 84、169、337 五种分辨率可选,这里分选择的值越小,图像的分辨率越高,扫 描得到的图像越大。一般的扫描我们推举使用 169 就可以得到 300dpi 的图像。
显示选择圈选图像的细节 表格形式显示所圈选的图像 显示所选泳道的峰值图 调整图像在圈选框中的位置 对图像的灰度值和浓度值做标准曲线 编辑分子标准
2 图象分析工具栏
3 图象分析
A 打开需要分析的图象,左侧的分析工具栏被激活 B 使用 矩形选择工具圈选图象上要分析的条带(尽可能小) C 系统自动给出该条带的灰度值 D 如果进行多个目标条带的分析,对多个目标条带进行圈选,然后拖动鼠标将 所有矩形框选中,则多个分析结果可以同时显示 软件分析的详细功能,请参照仪器说明书,并和相关技术支持联系
Odyssey 红外荧光扫描成像系统 培训手册
二 oo 三 年 九 月
目录
一、Odyssey 红外成像系统技术特点 二、系统安装条件 三、Western 实验所需试剂设备及样品 四、培训程序及时间安排 五、仪器及试剂系统介绍 六、Western 实验操作流程介绍 七、软件使用培训 八、常见问题处理 九、注意事项
Odyssey 的应用 应用领域:蛋白质研究,核酸研究 具体包括:Western 分析,In-Gel Western 分析,蛋白质定量分析,双色磷酸化
分析,考马司亮兰胶的扫描,蛋白双向电泳,双色 EMSA,双色微孔 板分析,BD PowerBlot Analysis,Northern Blot,Southern Blot 等
(避光)。
注:如果一抗稀释液中含有 0.1-0.2%的 Tween-20,则二抗稀释液也添加相同的 Tween-20。 如果使用 Tween-20 的同时添加 0.01-0.02%的 SDS 于二抗稀释液中可以比较好的降
低背景
15. 洗膜同 13(避光) 16. 用 PBS 洗去膜上残留的 Tween-20,接下来可直接进行扫描。 实验的详细的操作流程、注意事项、问题解决请参见附件以及《分子克隆实验 指南》。
Quality:图像的质量,在右侧的下拉框中选择需要的图像质量,一般的 Western blot 膜我们推荐使用 medium 即可。 Focus offset:聚焦平面选择,一般情况下当在上面 Preset 中选择好扫描选项后, 聚焦平面的值会根据上面的选择自动给出聚焦平面,一般来说,膜的聚焦平面为 零,胶的聚焦平面为胶厚度的一半(可根据胶实际的厚度手动输入) Channels:选择扫描的激光通道,根据所使用的二抗其激发后产生的发射光波长 为 720nm 或 820nm,选择相应的 700 或 800 通道,如果同时使用两个通道,也 可同时勾选这两种通道。 Intensity:在右侧的下拉框中选择激发光的强度,由 L2.0 至 10 共 24 种强度可 以选择,根据信号的强弱进行调整,信号弱时可将激发光强度相应调高。在进行 双通道扫描时,可根据不同的信号,设置不同的激光强度进行同步扫描。 Scan Area:在四个选项框中可以手动输入值,或者在右侧的 25×25 的扫描平面 模拟图中圈选要进行扫描的面积。
注:抗体的稀释倍数与抗体质量和实验中的蛋白样本相关,麻烦您根据经验选择合适稀 释倍数。同时,不同的抗体可能需要在抗体稀释液中含有 0.1-0.2%的 Tween-20 来 降低背景,您可以根据您要检测的蛋白以及平时操作经验来选择需否在一抗稀释液 中添加 0.1-0.2%的 Tween-20。
13. 之后用 PBST 于摇床洗膜 4×5mins。 14. 封闭液稀释二抗(建议比例为 1:3000~10000),膜在二抗中室温于摇床 1hour
注:封闭液可以用 5%的进口脱脂奶粉(用 PBS 溶解),因为 Tween-20 和 BSA 会对 Odyssey 造成高背景,所以在封闭完成前尽量不要让膜接触到这两种物质,所以麻 烦您确定封闭液中没有 Tween-20 和 BSA 成分。
12. 封闭液稀释一抗(建议比例为 1:1000-1:5000),膜在一抗中室温至少 1hour 或者 4℃过夜。
用甲醇浸湿,再用去离子水冲洗后转移到转移缓冲液中平衡 20min。) 8. 电泳胶置转移缓冲液中平衡 20min。 9. 裁两张与胶同样大小的滤纸,置转移缓冲液中平衡。 10. 转膜顺序:负极-专用滤纸-电泳胶-PVDF 膜-专用滤纸-正极。15V,电
转 30min。 11. 电: 1.在面板上打开仪器电源开关,再开启电脑,关机时相反。 2.用软布或无尘纸蘸双蒸水将扫描平面的玻璃擦拭干净。 3.将要扫描的胶或膜放到扫描平面上,记下坐标,扣上舱盖。 4.双击软件图标,输入用户名、密码,进入主菜单。 5.点击 scan 快捷键,选择要扫描的区域、介质、通道及合适的灵敏度、分辨率,
一、如何进行图像的扫描: 1 双击桌面上 Odyssey 的快捷方式图标
打开软件出现软件的使用界面
2 点击工具栏中 图标,建立一个新的 case
软件提示选择 case 的途径和名称,点击 Browse,选择 case 存储的位置,并在 name 栏中输入 case 的名称,点击 Done,软件提示将文件存储到相应的位置中
相关文档