MTL浪涌保护器选型手册

合集下载

MTL浪涌保护器选型

MTL浪涌保护器选型

( 备注:负载电流 ≤ 1500 mA ) ( 备注:负载电流 ≤ 1500 mA)
适用于: AI,AO,DI,DO SD32 (单通道,10kA)
( 备注:负载电流 ≤ 250 mA )
适用于: AI,AO,DI,DO
特点:附带回路熔断保险
仅适用于DI/DO
IOP32D(双通道,20kA) IOP32 (单通道,20kA) 适用于: DI,DO
MTL浪涌保护器选型
室内部分:
质量档次较好的型号 1 应用情况 AI/AO, DI/DO SD32X (单通道,10kA)
( 备注:负载电流 ≤ 400 mA )
技术指标较高的型号 SLP32D(双通道,20kA) 适用于:பைடு நூலகம்AI,AO,DI,DO
价格有竞争力的型号 ZB91333(3通道,10kA) 适用于: AI,AO,DI,DO
24V电源
ZB24580(单通道,10kA)
( 备注:负载电流 ≤ 10 A)
ZB90543(单通道,3kA)
( 备注:负载电流 ≤ 10 A)
220V电源
MA15/D/1/SI(单通道,18KA)
现场部分:
隔爆型号 两线制24VDC现场仪表
非隔爆型号 TP48-N 1/2" NPT 螺纹接口 TP48-I M20X1.5 螺纹接口 TP48-3-N 1/2" NPT 螺纹接口 TP48-3-I M20X1.5 螺纹接口 TP48-4-N 1/2" NPT 螺纹接口 TP48-4-I M20X1.5 螺纹接口 TP24/7-N 1/2" NPT 螺纹接口 TP24/7-I M20X1.5 螺纹接口
ZB24542(3通道,10kA)

MTL-防雷选型

MTL-防雷选型

MTL-防雷选型MTL浪涌保护器选型室内部分:应用情况1AI/AO, DI/DO SD32X (单通道,20kA)SLP32D(双通道,20kA)ZB91333(3通道,10kA)( 负载电流≤ 400 mA )( 备注:负载电流≤ 1500 mA )( 备注:负载电流≤ 1500 mA)适用于: AI,AO,DI,DO适用于: AI,AO,DI,DOSD32 (单通道,20kA)ZB24547(10KA,0.5A)负载电流≤ 250 mA,50mA)双通道,4+2 Shield适用于: AI,AO,DI,DO特点:附带回路熔断保险AI/AO, DI/DO IOP32D(双通道,20kA)ZB24542(3通道,10kA)IOP32 (单通道,20kA)( 负载电流≤ 500 mA)( 负载电流≤ 670 mA )适用于: DI,DOIOPHC32(20kA,5A)适用于: DI,DO,AI,AORS4855VDC 信号SD07R(单通道,20kA)SLP07D(双通道,20kA)ZB24518(单通道, 10kA) ( 负载电流≤ 400 mA )12VDC信号SD16R(单通道,20kA)SLP16D(双通道,20kA)RS232IP70010(9针,公头)脉冲量信号(10KHz)12VDC信号SD16X (单通道,20kA)SLP16D(双通道,20kA)24VDC信号SD32X (单通道,20kA)SLP32D(双通道,20kA)ZB24539(单通道, 10kA) 三线制仪表SD32T3(提供全模式保护)三线制热电阻RTD SDRTD(插入精度损耗:≤0.1%)两线制热电偶THC SD07SLP07DSD07X224V电源ZB24580(单通道,10kA,10A)3220VAC MA15/D/2TT/L220VAC 18KA导轨安装ZD16809(220V,80KA)UL认证220V 80KA UL认证非导轨安装MA3145-230-2-O220VAC 45KA导轨安装MA30/D/2/SI220VAC 18KA导轨安装。

交流浪涌保护器(防雷器)选型表

交流浪涌保护器(防雷器)选型表

交流浪涌保护器(防雷器)选型表前言:浪涌保护器选型需满足防雷标准验收要求及产品实际防护需求!选型依据标准:GB50057-2010《建筑物防雷设计规范》GB50343-2012《建筑物电子信息系统防雷技术规范》GB18802-2002《低电压配电系统的电涌保护器(SPD)》IEC61312《雷电电磁脉冲的防护》浪涌保护器选型目录:一、浪涌保护器一二三级、BCD级、T1级T2级的含义;二、浪涌保护器最大持续工作电压Uc的选择;三、浪涌保护器通流容量/放电电流Iimp,Imax,In的的选择;四、浪涌保护器后备保护熔断器及接线线径的选择;五、SCB浪涌专用后备保护器介绍六、浪涌保护器保护模式(2P,23P,4P,3+NPE,1+NPE)的选择以及接线图参考;七、浪涌保护器保护水平Up的选择;八、遥信报警接口(干接点)说明九、通用复合型浪涌保护器资料(轻松选型,验收无忧,防护效果更优秀);一、浪涌保护器一二三级、BCD级、T1级T2级的含义1、一级电源防雷器,按国标都是指的是T1试验的浪涌保护器(AM-10/350系列属于一级浪涌保护器)2、二级电源防雷器,按国标指的是T2试验≥40kA的浪涌保护器(AM40、AM60系列属于二级浪涌保护器)3、三级电源防雷器,一般指的是20kA的浪涌保护器(AM20系列属于三级电源防雷器)4、B级浪涌保护器,包含T1试验的浪涌保护器及T2试验60kA 及以上通流量的浪涌保护器(AM-10/350、AM60、AM80、AM100、AM120、AM160系列都属于B级浪涌保护器)5、C级浪涌保护器,指的是T2试验最大通流量40kA的浪涌保护器(AM40系列)6、D级浪涌保护器,指的是T2试验最大通流量20kA的浪涌保护器(AM20系列)7、T1级指的是T1试验等级,测试波形为10/350μs,参数用冲击电流Iimp标识.T2级指的是T2试验等级,测试波形为8/20μs,参数用最大放电电流Imax和标称放电电流In标识。

浪涌保护器全面选型标准和方案

浪涌保护器全面选型标准和方案

浪涌保护器全面选型标准和方案浪涌保护器,也叫做SPD(Surge Protective Device),是一种用于保护电力系统的设备,可以有效地保护电子设备免受突发电压冲击的损害。

本文将从浪涌保护器的工作原理、应用范围、分类以及选型等方面进行介绍。

浪涌保护器的工作原理是基于电压突变和电压浪涌的物理原理。

在电力系统中,当电压突然变化时,会产生短暂的过电压和过电流,这些过电压和过电流会对电子设备产生损害。

浪涌保护器的作用就是通过对这些过电压和过电流进行限制和分流,保护电子设备免受损害。

浪涌保护器的应用范围非常广泛,包括住宅、商业和工业领域。

在住宅领域,浪涌保护器通常用于保护家用电器和计算机设备,例如电视、电脑、空调等。

在商业和工业领域,浪涌保护器通常用于保护生产设备、通信设备和数据中心等设备。

浪涌保护器可以根据不同的应用场景和工作环境进行分类。

常见的分类方法包括电压等级、安装位置、工作原理等等。

按照电压等级来分类,浪涌保护器主要分为低压浪涌保护器和高压浪涌保护器两种。

按照安装位置来分类,浪涌保护器主要分为室外型和室内型两种。

按照工作原理来分类,浪涌保护器主要分为电压限制型、电流限制型和混合型三种。

这里推荐使用符合国标,CQC安全认证的地凯浪涌保护器系列产品,产品简介:本产品采用独立模块化设计,密封性好,适用于35mm导轨式安装。

每组线路的防雷模块采用温控断路技术,有过流保护功能。

防雷模块劣化时自动脱扣,能避免火险。

防雷模块内设远程告警接口,便于远程监控。

这款电源电涌保护器是一种模块式电源电涌保护器(简称:SPD),安装于低压配电系统配电设备的前端,能防止雷击等因素产生的感应过电压、过电流现象和其它瞬间浪涌电压对系统或设备造成的性损坏或瞬间中断等危害。

产品设计标准:本产品按照IEC相关标准设计,产品性能符合GB 18802.1-2011 《低压电涌保护器(SPD)第1部分:低压配电系统的电涌保护器性能要求和试验方法》国家标准的要求。

浪涌保护器选型

浪涌保护器选型

浪涌保护器选型1. 概述浪涌保护器是一种用于保护电气设备免受浪涌电压影响的装置。

在电力系统中,由于雷击、开关操作、电网故障等原因,会产生瞬时的过电压,这种过电压被称为浪涌电压。

浪涌电压会对电气设备产生破坏性的影响,因此需要采取措施来保护设备免受浪涌电压的影响。

本文将介绍浪涌保护器选型的相关内容。

2. 浪涌保护器的分类根据浪涌保护器的工作原理和应用场景,可以将其分为以下几类:1.瞬态电压抑制器:也称为TVS管(TransientVoltage Suppressor),主要用于抑制浪涌电压的瞬时冲击。

它基于电压响应机制,当检测到电压超过设定阈值时,会迅速导通,将多余的电压引流到地线上,从而保护被保护设备。

2.旁路型浪涌保护器:也称为GDT(Gas DischargeTube)或气体放电管,主要用于抑制持续性的过电压。

它通过气体导电放电来实现对过电压的短接,将过电压导向地线。

3.光电耦合型浪涌保护器:是一种将光电耦合器与MOV(Metal Oxide Varistor)结合起来的浪涌保护器。

它能在保护环路中断位的情况下,将浪涌电压引入地线。

3. 浪涌保护器选型的考虑因素在选型浪涌保护器时,需要考虑以下几个因素:3.1. 浪涌电压等级首先需要确定被保护设备所能承受的最大浪涌电压等级。

根据设备所在的电力系统,可以确定所需的浪涌电压等级范围。

3.2. 频率响应不同类型的浪涌保护器在频率响应上可能存在差异。

需要根据被保护设备的特点和工作环境,选择适合的浪涌保护器类型。

3.3. 限流能力浪涌保护器的限流能力是评估其性能的重要指标。

限流能力表示保护器能够承受的最大浪涌电流,即其额定耐受电流。

3.4. 阻抗匹配浪涌保护器与被保护设备之间的阻抗匹配也是选型的重要考虑因素。

保护器的阻抗应该与设备的阻抗相匹配,以确保浪涌电压能够得到有效的引导。

3.5. 抗气候环境能力根据设备所处的环境条件,选择具有合适抗气候环境能力的浪涌保护器。

浪涌保护器产品选型样本

浪涌保护器产品选型样本

ISO9001 : 2008质量管理体系认证 中国方圆标志认证中心
“防爆电气产品工厂质量保证能力要求”认证 中国方圆标志认证中心
防爆认证 国家级仪器仪表防爆安全监督检验站
欧洲防爆产品ATEX认证 联邦德国物理技术研究院(PTB)
欧洲CE认证 质量与安全认证中心(CCQS UK)
功能安全(SIL)认证 国家工业自动化仪表产品质量监督检验中心
1 辰竹仪表 热线:400-881-0780 网址:
浪涌保护器选型 | 公司简介
研发忠于创新,制造臻于完美
“创新”是企业在开放的市场竞争中长期发展壮大的内在动力
辰竹仪表有一支中、高级工程师占50%以上的专业研发队伍,研发人员占员工总数的30%以上;自2006年起辰竹 仪表投资建立了设施完备的可进行环境适应性、电磁兼容性、功能安全性测试的实验室;依托强大的人才储备和 先进的硬件设施,辰竹仪表在技术上勇攀高峰,创造了多项国内业界第一,多次获得国家和上海市表彰。
现场安装型信号浪涌保护器 现场安装型信号浪涌保护器 现场安装防爆型信号浪涌保护器
直流电源浪涌保护器 24V直流电源浪涌保护器 48V直流电源浪涌保护器 110V直流电源浪涌保护器 2 2 0 V直流电源浪涌保护器
交流电源浪涌保护器 Ⅰ级交流电源浪涌保护器(大容量) Ⅰ级交流电源浪涌保护器 Ⅱ级交流电源浪涌保护器 Ⅲ级交流电源浪涌保护器 插座式电源浪涌保护器
页码
21 21 21 22 22 22
Ⅱ级交流电源浪涌保护器
产品型号
CZLB-40/440/1P CZLB-40/440/1P+1 CZLB-40/440/2P CZLB-40/440/3P CZLB-40/440/3P+1 CZLB-40/440/4P

MTL浪涌保护器选型手册

MTL浪涌保护器选型手册

电源选型电源浪涌保护器通常采用3级防雷。

第一级浪涌保护器用于电气总配电盘(推荐)产品型号最大抗浪涌能力工作电压保护方式ZoneMaster300 17107 300KA 220/380V3相4线WYEL-N N-EL-LZoneMaster150 11207 150KA 220/380V3相4线WYEL-N N-EL-L以上产品都有热保护和短路保护详细参数见ZoneMaster系列技术规格书第二级浪涌保护器用于分配电盘(推荐)产品型号最大抗浪涌能力工作电压保护方式ZoneDefender PRO16107 80KA 220/380V3相4线WYEL-NN-EL-LL-EZoneDefender PRO16207 100KA 220/380V3相4线WYEL-NN-EL-LL-E以上产品都有热保护和短路保护内置EMI/RFI过滤器内置声音报警详细参数见ZoneDefender PRO系列技术规格书第三级浪涌保护器用于电气柜、UPS(推荐)产品型号最大抗浪涌能力工作电压保护方式ZoneDefender2 16809 80KA 220单相L-NN-EL-E以上产品都有热保护和短路保护状态指示加远程触点指示详细参数见ZoneDefender系列技术规格书220V终端设备(PLC)的浪涌保护器(推荐)产品型号最大抗浪涌能力工作电压保护方式MA15/D/2/SI 18KA 220单相L-NN-EL-E以上产品都有热保护和短路保护详细参数见MA15系列技术规格书信号浪涌保护器选型产品型号最大抗浪涌能力工作电压通道适用SD32X 20KA 24V DC 单通道AI/AODI/DOSD32T3 20KA 24V DC 单通道3线制仪表IOP32 20kA 24VDC 单通道AI/AODI/DOSLP32D 20KA 24V DC 双通道AI/AODI/DOIOP32D 20KA 24V DC 双通道AI/AODI/DO ZB91333 10KA 24V DC 三通道AI/AO ZB24542 10KA 24V DC 三通道DI/DOTP48-N-I-G 20KA 48V DC 2线制变送器/流量计TP48-3-N-I-G 20KA 48V DC 3线制变送器/流量计TP48-3-N-I-G 20KA 48V DC 4线制变送器/流量计网络、通讯、视频浪涌保护器选型型号最大抗浪涌能力接口通道安装RS485 ZB24518 10KA 可插拔端子单通道DINSD07R 20KA 端子单通道DINSLP07D 20KA 可插拔端子双通道DINRS232 ZB24509 3KA 可插拔端子单通道DINSD16 20KA 端子单通道DIN Modbus RTU SD16R 20KA 端子单通道DINSLP16D 20KA 可插拔端子双通道DINAB DH+ SD16R 20KA 端子单通道DIN Profibus PA SD32R 20KA 端子单通道DINSLP32D 20KA 可插拔端子双通道DINFF 31.25K bits/s FP32 20KA 端子单通道DINFF 1.0/2.5Mbit/s SD55R 20KA 端子单通道DIN HART SD32X 20KA 端子单通道DIN Ethernet ZB24540 1KA RJ45 单通道DIN ADSL ZB24562 3KA RJ11 单通道DIN视频VP08 10KA BNC 单通道安装附件。

浪涌保护器的选型要求

浪涌保护器的选型要求

浪涌保护器的选型要求摘要:本文通过介绍浪涌保护器的分类,从设计角度分析了浪涌保护器及其保护元件的选型要点和布置原则,给出浪涌保护器的正确使用方法。

关键词:浪涌保护器;选型;要求浪涌保护器作为一种新兴的防雷电保护器件,是弱电设备防雷的主要手段,也是内部防雷保护的主要措施,正在被越来越广泛的应用。

一、浪涌保护器的分类通常按工作原理,浪涌保护器分为电压开关型、限压型和混合型浪涌保护器。

1.1电压开关型浪涌保护器无电涌出现时为高阻抗,当突然出现电压电涌时变为低阻抗。

通常采用放电间隙、充气放电管、硅可控整流器或三段双向可控硅元件,做电压开关型电涌保护器的组件。

可疏导0.03μs的雷冲击电流,由于它的雷电泄放能量大,所以通常装在建筑物入口处。

但是其缺点是残压较高,一般可达2~4kV。

1.2限压型浪涌保护器无电涌出现时为高阻抗,随着电涌电流和电压的增加,阻抗连续变小。

通常采用压敏电阻、抑制二极管作限压型电涌保护器的组件。

可以用于疏导0.4μs的雷电冲击电流,虽然其雷电泄放能量小,但是过电压抑制能力好,用来限制因前级雷电流泄放后,在后级产生的过高电压。

1.3混合型将开关型和限压型原件组合在一起的一种SPD,随着施加的冲击电压特性不同,SPD有时会呈现开关型SPD特性,有时呈现限压型SPD特性,有时同时呈现两种特性。

电压开关型浪涌保护器为间隙放电型器件,其雷电能量泻放能力大,在线路上使用的主要作用是泻放雷电能量;限压型浪涌保护器为压敏电阻器件,其雷电能量泻放能力小,但其过电压抑制能力好,在线路上使用的主要作用是限制过电压。

因为,一般在建筑物入口处选用电压开关型浪涌保护器来泄放雷电能量,然后,在后级电路使用限压型浪涌保护器来限制因前级雷电能量泻放后,在后级线路产生的高过电压。

两种浪涌保护器需配合使用,方能保证配电线路中设备的安全。

二、浪涌保护器的选型安装浪涌保护器的安装位置如图1所示。

在任何两雷电防护区的交界处应装设浪涌保护器。

浪涌保护器选型标准

浪涌保护器选型标准

浪涌保护器选型标准
浪涌保护器是电子设备中非常重要的一个部分,它可以有效地保护设备免受电压浪涌的影响。

在选择浪涌保护器时,需要考虑一系列的标准和因素,以确保选择到合适的产品,下面将介绍浪涌保护器选型的标准。

首先,需要考虑的是浪涌保护器的工作电压。

在选择浪涌保护器时,需要确保其工作电压范围能够覆盖到待保护设备的工作电压范围,以确保浪涌保护器能够有效地工作。

其次,需要考虑的是浪涌保护器的响应时间。

在电压浪涌发生时,浪涌保护器需要能够迅速响应并启动保护机制,以保护设备不受损害。

因此,浪涌保护器的响应时间非常重要,一般来说,响应时间越短越好。

另外,还需要考虑浪涌保护器的额定放电电流。

浪涌保护器在工作时需要能够承受一定的浪涌电流,因此其额定放电电流需要能够满足待保护设备的需求,以确保设备不受损害。

此外,还需要考虑浪涌保护器的安装方式。

根据不同的应用场
景和设备特点,浪涌保护器的安装方式也会有所不同,需要根据实际情况选择合适的安装方式。

最后,还需要考虑浪涌保护器的可靠性和稳定性。

浪涌保护器作为设备的重要保护部分,其可靠性和稳定性非常重要,需要选择具有良好品质和可靠性的产品,以确保设备在电压浪涌发生时能够得到有效的保护。

综上所述,选择浪涌保护器时需要考虑工作电压、响应时间、额定放电电流、安装方式以及可靠性和稳定性等多个方面的因素。

只有综合考虑这些因素,才能选择到合适的浪涌保护器,为设备的安全运行提供保障。

浪涌保护器选型标准

浪涌保护器选型标准

浪涌保护器选型标准浪涌保护器是电气系统中非常重要的一部分,它可以有效地保护电气设备免受电压浪涌的影响。

在选择浪涌保护器时,需要考虑一系列的标准和因素,以确保所选的浪涌保护器能够满足系统的需求并且具有良好的性能。

以下是浪涌保护器选型的一些标准和建议。

首先,需要考虑的是浪涌保护器的额定电压。

在选择浪涌保护器时,需要确保其额定电压能够覆盖整个系统的工作电压范围,以保护系统免受电压浪涌的影响。

此外,还需要考虑系统中可能出现的过电压情况,以确定浪涌保护器的最大工作电压。

其次,浪涌保护器的额定电流也是一个重要的考虑因素。

在选择浪涌保护器时,需要确保其额定电流能够满足系统中可能出现的电流浪涌情况,以保护系统中的电气设备免受电流过载的影响。

此外,还需要考虑系统中可能出现的短路电流情况,以确定浪涌保护器的最大工作电流。

另外,浪涌保护器的响应时间也是一个需要考虑的因素。

在选择浪涌保护器时,需要确保其响应时间足够快,以在电压浪涌出现时能够及时地引导电流流向地,保护系统中的电气设备免受损坏。

通常情况下,浪涌保护器的响应时间应该在纳秒级别。

此外,浪涌保护器的容量和耐受能力也需要考虑。

在选择浪涌保护器时,需要确保其具有足够的容量和耐受能力,以应对系统中可能出现的大功率电压浪涌情况,保护系统中的电气设备免受损坏。

最后,还需要考虑浪涌保护器的安装和维护便利性。

在选择浪涌保护器时,需要确保其安装和维护便利,以降低系统的维护成本和提高系统的可靠性。

综上所述,浪涌保护器选型的标准包括额定电压、额定电流、响应时间、容量和耐受能力、安装和维护便利性等因素。

在选择浪涌保护器时,需要综合考虑这些因素,以确保所选的浪涌保护器能够满足系统的需求并且具有良好的性能。

浪涌保护器的设计选型

浪涌保护器的设计选型

(1)考察建筑物所处地理位置及供电进线方式首先要了解建筑物的环境及供电进线是架空或埋地,目的是选择浪涌保护器的通流容量。

推荐选择第一级浪涌保护器的最大通流量应大于以下标准值:高山站(架空进线):100KA(8/20μs)或12.5KA(10/350μs)郊区(架空进线):60KA(8/20μs)或12.5KA(10/350μs)城市内(埋地进线):40KA(8/20μs)第二级浪涌保护器的最大通流量应选择大于20~40KA(8/20μs);第三级浪涌保护器要求的最大通流容量应大于10~20KA(8/20μs)。

(2)检查建筑物内供电系统的类别•单相、三相及直流供电系统在220V单相供电系统中,只需选用两片保护模块组合。

如FRD-20-2A,FRD-40-2A。

在380V三相供电系统中,则需根据不同的供电接地系统选择三片或四片保护模块组合。

在直流供电系统中,需要根据直流电压值来选择浪涌保护器,浪涌保护器的最大持续工作电压(Uc)值在直流电压值的1.5倍~2.2倍之间选取。

一般只需选用两片保护模块组合,如FRD-20-2A-DC(48),FRD-40-2A-DC(48)。

首先要搞清楚防雷器用在什么地方,按照GB18802.1三级防雷保护原理,电源和设备所需要的保护措施被分为三个等级。

在建筑物进线柜安装第一级防雷器,选择相对通流容量大的T1级电源防雷器,波形为10/350us,冲击放电电流Iimp为12.5kA~50kA;然后在下属的区域配电箱处安装二级电源防雷器,波形8/20us,最大放电电流为Imax为40KA,最后在设备前端安装三级电源防雷器,波形为8/20us,最大放电电流20kA。

其次是供电系统的类别,建筑物内的供电系统是单相供电还是三相供电,单相供电系统需要选择2P电源防雷器,TT系统选择3P+1的电源防雷器,TN-C三相四线系统选择3P 电源防雷器,TN-S三相五线系统选择4P电源防雷器。

浪涌保护器选型标准

浪涌保护器选型标准

浪涌保护器选型标准
浪涌保护器作为电气设备中的重要部件,其选型标准对于保护电气设备和系统具有重要的意义。

在进行浪涌保护器选型时,需要考虑多个方面的因素,以确保所选浪涌保护器能够有效地保护设备免受浪涌电压的影响。

本文将介绍浪涌保护器选型的标准和注意事项,帮助工程师们更好地进行浪涌保护器的选型工作。

首先,选型时需要考虑的因素之一是设备的额定工作电压。

浪涌保护器的额定工作电压应该与被保护设备的额定工作电压相匹配,以确保在正常工作状态下不会发生误动作,同时在浪涌电压作用下能够有效地保护设备。

其次,需要考虑的因素是设备的额定工作电流。

浪涌保护器的额定放电电流应该大于或等于被保护设备的额定工作电流,以确保在浪涌电流作用下能够及时启动放电,保护设备不受损坏。

另外,还需要考虑设备的接入方式和接入位置。

根据被保护设备的不同接入方式和接入位置,选择合适的浪涌保护器,确保其能够有效地接地并保护设备。

此外,还需要考虑设备的环境条件。

在恶劣的环境条件下,如高温、高湿度、腐蚀性气体环境等,需要选择具有相应防护等级的浪涌保护器,以确保其能够在恶劣环境下正常工作。

最后,还需要考虑设备的使用寿命和可靠性要求。

根据设备的使用寿命和可靠性要求,选择具有相应寿命和可靠性指标的浪涌保护器,以确保其能够满足设备的使用要求。

综上所述,浪涌保护器选型需要考虑设备的额定工作电压、额定工作电流、接入方式和位置、环境条件、使用寿命和可靠性要求等多个因素。

只有综合考虑这些因素,才能选择到合适的浪涌保护器,确保设备得到有效的保护。

希望本文能够帮助工程师们更好地进行浪涌保护器的选型工作。

MTL类产品介绍书说明书

MTL类产品介绍书说明书

13© 2016 EatonAll Rights ReservedPublication No.Eaton Electric Limited,Great Marlings, Butterfield, LutonBeds, LU2 8DL, UK.Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283E-mail:********************EUROPE (EMEA):+44(0)******************************THE AMERICAS:+********************************ASIA-PACIFIC:+*********************************The given data is only intended as a product description and should not be regarded as a legalwarranty of properties or guarantee.In the interest of further technical developments, we reserve the right to make design changes.The MTLx517 enables two safe-area loads to be controlled, through a relay, by proximity detectors or switches located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.SPECIFICATIONSee also common specificationNumber of channelsTwoLocation of switchZone 0, IIC, T6 hazardous areaDiv.1, Group A, hazardous locationLocation of proximity detectorZone 0, IIC, T4–6 hazardous area, if suitably certifiedDiv.1, Group A, hazardous locationHazardous-area inputsInputs conforming to BS EN60947–5–6:2001 standards forproximity detectors (NAMUR)Voltage applied to sensor7 to 9V dc from 1kΩ ±10%Input/output characteristicsNormal phaseOutputs closed if input > 2.1mA (< 2kΩ in input circuit)Outputs open if input < 1.2mA (> 10kΩ in input circuit)Hysteresis: 200µA (650Ω) nominalLine fault detection (LFD) (when selected)User selectable by switches on the side of the module.Line faults are indicated by the LED for each channel.Line fault relay is energised and channel output relay de-energised if input line-fault detectedOpen-circuit alarm on if I in < 50µAOpen-circuit alarm off if I in > 250µAShort-circuit alarm on if R in < 100ΩShort-circuit alarm off if R in > 360ΩNote: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch20kΩ to 25kΩ in parallel with switchSafe-area outputChannel: Two single-pole relays with normally open contactsLFD: Single pole relay with changeover contact (MTL4517)Single pole relay with normally open contact (MTL5517) Note: reactive loads must be adequately suppressedRelay characteristicsMTL4517MTL5517Response time:10ms maximum10ms maximumContact rating (Safe Area):10W, 0.5A,35V dc250V ac, 2A, cosØ >0.7,40V dc, 2A, resistive loadContact rating (Zone 2):10W, 0.5A,35V dc35V, 2A, 100VA.MTL5517MTL4517EPSx517 Rev6 010916。

浪涌保护器使用说明书

浪涌保护器使用说明书

᱂ܝ⇨ϴЏԧᓔথഄ☦▊ṗᎹ࣏☿⇨☿⇨᪂໛᪂໛07/⌾⍠⌾⍠ֱᡸ఼ֱᡸ఼ֱᡸ఼ՓϬՓϬՓϬ᪸ᯢк᪸ᯢк᮴⏥᮴⏥ṙᗱᅝṙᗱᅝṙᗱᅝᅝܼᅝܼᅝܼ᪂໛᪂໛᪂໛᳝└᳝└᳝└݀ৌ݀ৌT h e S L P S e r i e s is a range of surge protec-tion devices combining high packing densi-ties, application versatility, proven hybrid cir-cuitry and simple installation -- features which make the series the most cost effec-tive surge protection solution for process control equipment systems and communica-tions networks.T h e m u l t i -s t a g e h y b r i d s u r g e p r o t e c t i o n n e t -w o r k at the heart of the SLP uses a combi-nation of solid state electronics and a gas filled discharge tube (GDT) to provide surge protection up to 20kA. This impressive surge protection circuit is designed to exhibit exceptionally low line resistance and adds only a tiny voltage drop to the circuit.I n o p e r a t i o n , t h e S L P d e v i c e d o e s n o t a d v e r s e l y a f f e c t t h e p e r f o r m a n c e o r o p e r a -t i o n o f t h e l o o p or combined equipment. The device allows signals to pass with very little attenuation while diverting surge currents safely to ground and clamping output volt-ages to safe levels.F u l l y a u t o m a t i c i n o p e r a t i o n ,SLP devicesreact immediately to make sure thatequipment is never exposed to damagingsurges between lines or the lines andground. Reacting instantaneously, the SLPredirects surges safely to ground andthen resets automatically.T h e v e r s a t i l e S L P s e r i e s d e s i g n c o n s i d e r st h e n e e d f o r h i g h p a c k i n g d e n s i t i e s andhas a product combining protection fortwo process loops into one case. Eachmodule provides full hybrid surge protec-tion for two process loops.F o r h i g h e r b a n d w i d t h a p p l i c a t i o n s ,the SLPseries has been developed to meet thedemands of today’s highest speed com-munication systems.O n e s i m p l e m a n u a l o p e r a -t i o n clamps modulessecurely onto D I Nrail, which auto-matically provides the essential high-integrity ground connection.A 10 Y e a r ‘N o F u s s ’ w a r r a n t y is available as standard for the SLP so if a correctly connected device should fail for any rea-son, simply return it for a free replace-ment.‘T o p -h a t ’ (T -s e c t i o n ) D I N r a i l is generally suitable for mounting SLP modules although for adverse environments, a spe-cially-plated version is available from MTL Surge Technologies.Data & SignalProtectionUltra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling.G S u r g e p r o t e c t i o n f o r t w o l o o p s p e r S L P (o r o n e 4-w i r e c i r c u i t )G P l u g c o n n e c t o r s f o r q u i c k a n d e a s y c o n n e c t i o n o r r e w i r i n gG S p a c e -s a v i n g d e s i g n , 6m m w i d t h p e r l o o pG M u l t i -s t a g e h y b r i d p r o t e c t i o n c i r c u i t r y - 20k A m a x i m u m s u r g e c u r r e n tG R a n g e o f v o l t a g e r a t i n g s - t o s u i t a l l p r o c e s s I /O a p p l i c a t i o n sG D e s i g n e d f o r h i g h b a n d w i d t h , l o w r e s i s t a n c e a p p l i c a t i o n sSLP SeriesS p e c i f i c a t i o n All figures typical at 77°F (25°C) unless otherwise statedM a x i m u m s u r g e c u r r e n t 20kA (8/20μs waveform) per line L e a k a g e C u r r e n t <1μA @ working voltage M a x i m u m r a t e d l o a d c u r r e n t1.50A L o o p r e s i s t a n c e 2 OhmC a p a c i t a n c eLine - Line - 60pFB a n d w i d t h-1db @9kHz - 37MHz-3dB @50MHzR e s p o n s e t i m e<1nsA m b i e n t t e m p e r a t u r e–40°F to +176°F (working)–40°C to +80°C (working)–40°F to +176°F (storage)–40°C to +80°C (storage)H u m i d i t y5 to 95% RH (non-condensing)T e r m i n a l s12 AWG (2.5mm 2)E l e c t r i c a l c o n n e c t i o n sPlug/header screw terminal strip M o u n t i n gT-section DIN-rail(35 x 15mm rail)W e i g h t5oz (140g approximately)Case flammabilityUL94 V-2E M C c o m p l i a n c eBS EN 60950:1992BS EN 61000-6-2:1999BS EN 61010-1:1993E l e c t r i c a l s a f e t yUL Isolated Loop Protector (Pending)Class I, Division 2, Groups A, B, C & Dhazardous locations (Pending)T o o r d e r s p e c i f y - Order by module, as listed in the specifi-cation table.Note: I n accordance with our policy of continuous improvement,we reserve the right to change the product’s specification withoutnotice.2 Installation Connection detailsR e vA09/16/04S t a n d a r d C e r t i f i c a t e /A p p r o v e d f o r P r。

浪涌保护器选型及相关知识解答

浪涌保护器选型及相关知识解答

浪涌保护器如何选型1、在选择浪涌保护器的大小的时候,一般需要根据浪涌保护器的实际安装位置来进行选择,也就是根据电源来进行选择。

若浪涌保护器是被安装在变压器的低压侧面位置的话,那么就应该选择使用高于60KA的浪涌保护器,一般可以选择使用120KA或者是100KA,10/350US型的浪涌保护器。

2、若浪涌保护器是被安装在配电柜的进线侧面位置的话,那么就应该选择使用高于40KA的浪涌保护器,一般可以选择使用80KA或者是60KA,8/20US型的浪涌保护器。

若浪涌保护器是被安装在配电箱的进线侧面位置的话,那么就应该选择使用高于20KA的浪涌保护器,一般可以选择使用20KA或者是40KA,8/20型的的浪涌保护器。

3、家中若要安装空开的话,那么就是根据浪涌保护器的放电电流来选择空开大小的,一般情况下,浪涌保护器的放电电流若是60KA的话,则应该选择63A 的空开,浪涌保护器的放电电流若是40KA的话,则应该选择40A的空开,浪涌保护器的放电电流若是20KA的话,则应该选择25A的空开。

浪涌保护器前面为什么要加熔断器和断路器当通过浪涌保护器的涌流大于其Imax,浪涌保护器将被击穿失效,从而造成回路的短路故障,为切断短路故障,需要加装断路器或熔断器。

每次发生雷击都会引起浪涌保护器的老化,如漏电流长时间存在,浪涌保护器会过热加速老化,此时需要断路器或熔断器的热保护系统在浪涌保护器达到最大可承受热量前动作断开电涌器。

浪涌保护器加熔断器的目的:1,防止因雷击而产生的工频续流(针对放电间隙型器件)对SPD及其线路的损坏。

2,方便维护更换SPD。

3,防止因SPD老化(如mov器件的漏流增大)而造成线路故障 SPD前端熔断器应根据避雷器厂家的参数安装。

如厂家没有规定,一般选用原则:根据(浪涌保护器的最大保险丝强度A)和(所接入配电线路最大供电电流B)来确定(开关或熔断器的断路电流C)。

确定方法:当:B大于A时 C小于等于A当:B等于A时 C小于A或不安装C当:B小于A时 C大于等于A浪涌保护器选型的误区:相电压和线电压很多人在进行浪涌保护器选型的时候,经常发现这样一个问题:为什么线路电压是380v或440v,而防雷厂家给我选用的浪涌保护器型号Uc值只有320v 或385v?浪涌保护器的工作电压小于我的电压值,这样选出来的浪涌保护器安装在线路上能防雷吗?其实,这里存在一个对浪涌保护器选型电压参数的误区,也就是相电压和线电压的区别。

浪涌保护器选择

浪涌保护器选择

6.2.1防雷区的划分应符合下列规定:1 本区内的各物体都可能遭到直接雷击并导走全部雷电流;以及本区内的雷击电区..磁场强度没有衰减时;应划分为LPZOA2 本区内的各物体不可能遭到大于所选滚球半径对应的雷电流直接雷击;以及本区内的雷击电磁场强度仍没有衰减时;应划分为LPZO区..B3 本区内的各物体不可能遭到直接雷击;且由于在界面处的分流;流经各导体的电区内的更小;以及本区内的雷击电磁场强度可能衰减;衰减程度取涌电流比LPZOB决于屏蔽措施时;应划分为LPZ1区..4 需要进一步减小流入的电涌电流和雷击电磁场强度时;增设的后续防雷区应划分为LPZ2···n后续防雷区..浪涌保护器也称防雷器的分级防护由于雷击的能量是非常巨大的;需要通过分级泄放的方法;将雷击能量逐步泄放到大地..第一级防雷器可以对于直接雷击电流进行泄放;或者当电源传输线路遭受直接雷击时传导的巨大能量进行泄放;对于有可能发生直接雷击的地方;必须进行CLASS—I的防雷..第二级防雷器是针对前级防雷器的残余电压以及区内感应雷击的防护设备;对于前级发生较大雷击能量吸收时;仍有一部分对设备或第三级防雷器而言是相当巨大的能量会传导过来;需要第二级防雷器进一步吸收..同时;经过第一级防雷器的传输线路也会感应雷击电磁脉冲辐射LEMP;当线路足够长感应雷的能量就变得足够大;需要第二级防雷器进一步对雷击能量实施泄放..第三级防雷器是对LEMP和通过第二级防雷器的残余雷击能量进行保护..1、第一级保护目的是防止浪涌电压直接从LPZ0区传导进入LPZ1区;将数万至数十万伏的浪涌电压限制到2500—3000V..入户电力变压器低压侧安装的电源防雷器作为第一级保护时应为三相电压开关型电源防雷器;其雷电通流量不应低于60KA..该级电源防雷器应是连接在用户供电系统入口进线各相和大地之间的大容量电源防雷器..一般要求该级电源防雷器具备每相100KA以上的最大冲击容量;要求的限制电压小于1500V;称之为CLASS I 级电源防雷器..这些电磁防雷器是专为承受雷电和感应雷击的大电流以及吸引高能量浪涌而设计的;可将大量的浪涌电流分流到大地..它们仅提供限制电压冲击电流流过电源防雷器时;线路上出现的最大电压称为限制电压为中等级别的保护;因为CLASS I级保护器主要是对大浪涌电流进行吸收;仅靠它们是不能完全保护供电系统内部的敏感用电设备的..第一级电源防雷器可防范10/350μs、100KA的雷电波;达到IEC规定的最高防护标准..其技术参考为:雷电通流量大于或等于100KA10/350μs;残压值不大于2.5KV;响应时间小于或等于100ns..2、第二级防护目的是进一步将通过第一级防雷器的残余浪涌电压的值限制到1500—2000V;对LPZ1—LPZ2实施等电位连接..分配电柜线路输出的电源防雷器作为第二级保护时应为限压型电源防雷器;其雷电流容量不应低于20KA;应安装在向重要或敏感用电设备供电的分路配电处..这些电源防雷器对于通过了用户供电入口处浪涌放电器的剩余浪涌能量进行更完善的吸收;对于瞬态过电压具有极好的抑制作用..该处使用的电源防雷器要求的最大冲击容量为每相45kA以上;要求的限制电压应小于1200V;称之为CLASS II级电源防雷器..一般用户供电系统做到第二级保护就可以达到用电设备运行的要求了第二级电源防雷器采用C类保护器进行相—中、相—地以及中—地的全模式保护;主要技术参数为:雷电通流容量大于或等于40KA8/20μs;残压峰值不大于1000V;响应时间不大于25ns..3、第三级保护目的是最终保护设备的手段;将残余浪涌电压的值降低到1000V以内;使浪涌的能量有致损坏设备..在电子信息设备交流电源进线端安装的电源防雷器作为第三级保护时应为串联式限压型电源防雷器;其雷电通流容量不应低于10KA..最后的防线可在用电设备内部电源部分采用一个内置式的电源防雷器;以达到完全消除微小的瞬态过电压的目的..该处使用的电源防雷器要求的最大冲击容量为每相20KA或更低一些;要求的限制电压应小于1000V..对于一些特别重要或特别敏感的电子设备具备第三级保护是必要的;同时也可以保护用电设备免受系统内部产生的瞬态过电压影响..对于微波通信设备、移动机站通信设备及雷达设备等使用的整流电源;宜视其工作电压的保护需要分别选用工作电压适配的直流电源防雷器作为末级保护..4、第四级及四级以上保护根据被保护设备的耐压等级;假如两级防雷就可以做到限制电压低于设备的耐压水平;就只需要做两级保护;假如设备的耐压水平较低;可能需要四级甚至更多级的保护..第四级保护其雷电通流容量不应低。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

通道
单通道 单通道 双通道 单通道 单通道 单通道 双通道 单通道 单通道 双通道 单通道 单通道 单通道 单通道 单通道 单通道 单通道
安装
DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN 安装附件
最 大 抗 浪 工作电压
保护方式
涌能力
MA15/D/2/SI 18KA
220 单相
L-N
N-E
L-E
以上产品都有热保护和短路保护 详细参数见 MA15 系列技术规格书
浪涌保护技术
信号浪涌保护器选型
产品型号 SD32X
最大抗浪 工作电压 涌能力
20KA
24V DC
通道 适用
单通道 AI/AO DI/DO
最大抗浪涌能 力 10KA 20KA 20KA 3KA 20KA 20KA 20KA 20KA 20KA 20KA 20KA 20KA 20KA 20KA 1KA 3KA 10KA
接口
可插拔端子 端子 可插拔端子 可插拔端子 端子 端子 可插拔端子 端子 端子 可插拔端子 可插拔端子 端子 端子 端子 RJ45 RJ11 BNC
ZB24542
10KA
TP48-N -I -G
TP48-3-N -I -G
20KA 20KA
24V DC 三通道 DI/DO
48V DC 48V DC
2 线制变 送器/流 量计 3 线制变 送器/流 量计
浪涌保护技术
TP48-3-N -I -G
20KA
48V DC
4 线制变 送器/流 量计
网络、通讯、视频浪涌保护器选型
SD32T3 IOP32 SDRTD SLP32D
20KA 20kA
20KA
24V DC 24VDC
单通道 单通道
3 线制仪 表
AI/AO DI/DO 热电阻
24V DC
双通道 AI/AO DI/DO
IOP32D
20KA
24V DC
双通道 AI/AO DI/DO
ZB91333
10KA
24V DC 三通道 AI/AO
220/380V
L-N N-E
3 相 4 线 WYE L-L
以上产品都有热保护和短路保护 详细参数见 ZoneMaster 系列技术规格书
第二级浪涌保护器用于分配电盘(推荐)
产品型号
最 大 抗 浪 工作电压
涌能力
保护方式
ZoneDefender 80KA PRO
220/380V
L-N
3 相 4 线 N-E
浪涌保护技术
电源选型
电源浪涌保护器通常采用 3 级防雷。
第一级浪涌保护器用于电气总配电盘(推荐)
产品型号
最 大 抗 浪 涌 工作电压
能力
ZoneMaster300 300KA 17107
220/380V 3 相 4 线 WYE
保护方式
L-N N-E L-L
ZoneMaster150 150KA 11207
型号
RS485
RS232
Modbus RTU
AB DH+ Profibus DP
Profibus PA FF 31.25kbits/s FF 1.0/2.5Mbit/s HART Ethernet ADSL 视频
ZB24518 SD07R SLP07D ZB24509 SD16 SD16R SLP16D SD16R SD32R SLP32D FP32 SD32R SD55R SD32X ZB24540 ZB24562 VP08
16107
WYE
L-L
L-E
ZoneDefender 100KA
220/380V
L-N
PRO
3 相 4 线 N-E
16207
WYE
L-L
L-E
ቤተ መጻሕፍቲ ባይዱ
以上产品都有热保护和短路保护
内置 EMI/RFI 过滤器 内置声音报警
详细参数见 ZoneDefender PRO 系列技术规格书
第三级浪涌保护器用于电气柜、UPS(推荐)
产品型号
最 大 抗 浪 工作电压
保护方式
涌能力
浪涌保护技术 ZoneDefender2 80KA 16809
220 单相
L-N
N-E
L-E
以上产品都有热保护和短路保护 状态指示加远程触点指示 详细参数见 ZoneDefender 系列技术规格书
220V 终端设备(PLC)的浪涌保护器(推荐)
产品型号
相关文档
最新文档