SWL-C Testing Data
OSO Technology Co.,Ltd.
The oscilloscope will show the profile of the C-band (1525nm-1570nm) output from SWL-C.
(2) Input laser beam to an Etalon (100GHz) and
a FBG (1527.975nm) wavelength marker:
Oscilloscope SWL-C
PD
Etalon
(100GHz)
FBG
Photos of SWL-C scanning an Etalon (100GHz) and a wavelength marker (1527.975nm)
(3) Input laser beam to 3 of serial FBG and input
the reflected wavelengths to an oscilloscope.
Oscilloscope SWL-C
FBG
Coupler
50/50
1530nm1550nm1570nm
PD
Photos of SWL scanning 3 FBG with wavelength 1530,1550 and 1570nm respectively
(4) Temperature Stability Test: Transmission peak
moved <10nm for 40 temperature change
20 (peak:1583.56nm)60 (peak:1574.76nm)
(5) DC tuning Demo:
•Slide Control Switch to EXT. position in the front panel. •Input a 0 to +40Vdc tunable voltage to the EXT. IN at the real
panel.
0---+40Vdc
SWL-C OSA
From OSA you can get single line output from 1525nm to 1570nm for different EXT. voltage. The line width is less than 0.02nm.
LOGO
11
OSO Technology Co., Ltd.(+86) 10 8491 0226sales@ 108 301-307 100101 (ADD)
(PC) (Tel):
Email:
(Web):