上海稳利达电气有限公司S H A N G H A I W E N L I D A E L E C T R I C C O ., L T D .上海稳利达科技股份有限公司S H A N G H A I W E N L I D A T E C H N O L O G Y .,L T D产品说明书Compensation AC stabilizerProduct descriptionSBW•DBW series automatic compensating alternative stabilizers are new products with voltage stable and protect functions, this product combining the mostadvanced European technology with our national condition.When the fluctuation of voltage occurs or load changes,it can automatically keep the stability of the output voltage.These series prod-ucts have the advantages of large capacity,high efficiency.small waveform deformation,smooth voltage regulation.wide range of load,the ability of undertaking instant overload,longterm continuous operation, manual & automatic control mode, protective function of overvoltage, short circuit and mechanical transmission failure.small volume and weight.easy and convenient usage,and reliable opera-tion.etc.These series products are widely used in the places requiring stable voltage such as in industry,agriculture,transportation,military, railway, postal offices, and scientific research institutes, which are includinglarge industrial production line, medical devices.architectural equipments.testing equipments,broadcast and TV stations, telecom statiions, air-conditional computer rooms, etc.Product descriptionChapter I overview1、TypeThis series of stabilizers' model shown in the figure:Rated capacity (KVA)Design StabilizerCompensating deviceS:three-phaseD:single-phaseB w2、Host machine and main components��Chapter I overview��Chapter I overviewSBW·DBW series stabilizer should be used indoors,normal conditions are as follows ① Temperature: -15~+45℃ ② Altitude: ≤1000m; ③ Relative Humidity: ≤90%;④ Installation position: no such materials serious effects on the Insulation of stabiliz-er, as gases,steam, chemical deposition, dust, dirt, and other explosive and erosive medium; ⑤ There is no serious fluctuation in installation position;⑥ If any of above conditions are not satisfied, it is suggested that user and WENLIDAarrange the installation.4、operation condition5、Working principles��Chapter I overviewStabilizer includes compensating circuit, voltage inspection circuit, feedback loop,servo-motor circuit and deceleration driving circuit, mainloop switch circuit,voltage and current measurement loop, and protection circuit.Three phase stabilizerSingle phase stabilizerInputOutput① When installing the stabilizer, the user should check in advance whether the grid line connected to the stabilizer is unblocked, including whether the contacts and sockets are in good contact, so as to avoid introducing open circuit or short-circuit faults.② When installing, pay attention to good grounding. If the mains input ground wire is floating, the input voltage between neutral and earth wire may reach 100V; if the user load has strict requirements for the neutral and earth wire voltage of the power supply system, please pay attention to the mains good grpounding to the mains good.③ When the user installs the stabilized power supply, do not connect the input and output neutral, live and earth wires of the stabilizer in reverse or wrong to avoid electrical short circuit; at the same time, check whether the input mains voltage is normal.④ Installation requirements for stabilizer:Place the stabilizer flat on the ground (avoid inclined, uneven ground).Do not place objects on top of the stabilizer, nor should anyone sit on it.Do not place it in a place containing corrosive gas.Chapter II installation and commissioningChapter II installation and commissioning1、Installation considerations2、On-site environmental requirements3、Display parameter setting① CleanSundries and rubbish should not be piled around the equipment. Droplets and metals dropped or placed inadvertently may cause short circuits and endanger the system and personal safety. Dust, dirt or debris on the equipment exhaust holes will hinder air circulation, thereby affecting the cooling effect of the fan. Cause the system to shutdown due to excessive temperature.The civil construction of the computer room should be completed, and the floor has been hardened. The site should be clean, dry and dust-free.② Fire protectionIt is strictly forbidden to store flammable and explosive hazardous materials in the equipment room.In order to reduce the possibility of fire and reduce the damage caused by this, the walls, ceiling and floor of the equipment room should be made of fire-resistant materials and equipped with suitable and effective fire-fighting equip-ment (e.g. portable CO2 fire extinguishers).③ Ventilation and heat dissipationIn order to facilitate operation and maintenance and heat dissipation of the equip-ment, at least 30-50cm should be left around the frame and 50cm should be left on theupper part.��Chapter II installation and commissioning① Display pictureChapter II installation and commissioningSETvoltage/phase voltage display.Press this button for 2 seconds to display the operating frequency and internaltemperature of the system. The left side is the frequency value, and the right side is ③ Display instructiong��Chapter II installation and commissioning⑥ Parameter setting descriptionP01P02P03P04P05P06P07Regulating accuracy Return voltage Overcurrent protection valueOvercurrent delayCurrent mutual inductance rdtio Overpressure upoer limit Overvoltage delayUpper and Umit Range Setting of Back-to-Middle voltage ValueOutput voltage setting valueWhen the actual phase current value is continuously greater than this item for x seconds,the over-current protetion function will beactivated when the maximun value is turned offThe actual current is continuously greater than the overcurrent protection value.After this delay, the overcurrent protection functionis activated The actual output line voltage value is continuously higher than this item after X seconds,the overcurrent protection functionbe activatedThe actual output line voltage value is continuously higher than this item after X seconds,the overcurrent protection functionis activated(unit/second)The range of external current sensor is from 25:5 to 2500:5P08 P09 P10 P11P12Undervoltage lower limitUndervoltage delayUnderpressure thresholdProtecion optionsRelay multiplexing settingsThe octual output line coltage volue is continusly less thon this itemfor X seconds,the undervoltage protection function will beactivatedThe octual voltage is continuously lower limit ofundervoltage protection after this delay (unit/second)(0-5) 10VSee protection instructions0.0:automatic judgment 0.1:fixed 50Hz 0.2:f ixed 60HzDelayed closing time of main output relay offer voltage stabilization(unit/second)1.Protection or alarm2.Main output controlDescription:1.Applicable to equipment knowledge input terminalwith electric operation device2.Applicable to equipment output terminal plus AC contactor (withstore line voltage stabilization and delay outpuut function)lnoperableVoltage Error Correction,Range Positive and Negative 6.0vVoltage Error Correction,Range Positive and Negative 6.0vVoltage Error Correction,Range Positive and Negative 6.0vVoltage Error Correction,Range Positive and Negative 6.0v Main output delayWorking frequency selectionCommunication station numberReverse phase detectionSystem settingsUAB voltage correction valueUBC voltage correction valueUCA voltage correction valueUab voltage correction valueP13 P14P15 P16 P17 P18 P19 P20 P21Optional node number with isolated Rs485communication interface0:reverse phase and open phase detection function off1:reverse phase and open phase detection function open*Chapter II installation and commissioningChapter II installation and commissioningThe range(0-5) 10V is 0V-50V,if it is set to 2,it is 20V.When the three-phase output sampling voltage is lower thar 20V,undervoltage will not be detected.The machine isnormal.Applicable to the three-phase output voltage sampling line connected behind the switch.Voltage Error Correction,Range Positive and Negative 6.0v Ubc voltage corrction value Uca voltage corrction value Fault record flag Voltage regulation setting Voltage Error Correction,Range Positive and Negative 6.0v 0:Clear alarm and record information 1:Record fault information completed 1:Manual voltage regulation 2:Automatic voltage regulationP22P23P24P2512345⑦ Protection setting descriptionOnly the overcurrent protection is enabled,and the overvoltage and undervoltage protection fucnctions are not enabled.After protection,the relay control is turned on/the main output is turned off,and it is restored manually.The overcurrent,overvoltage,and undervoltage protection starts.After protection,the relay control is turned on/the main output is not turned off,and it is restored manually.Overcurrent,overvoltage,and undervoltage protection starts.After the protection,the relay control is turned on/the main output is not turned off,ln the case of over-voltage protection and under-voltage protection,the voltage will be automatically restored if it is normal for 60 seconds.The overcurrent,overvoltage,and undervoltage protections are activated.After protection,the relay control is turned on/the main output is turned off,and it is restored manually.The overcurrent,overvoltage,and undervoltage protection starts.After the protection, the relay control is turned on/the main output is turned off.ln the case of over-voltage and under-voltage protection,the voltage will be automatically restored if it is normal for 60 seconds.⑧ Underpressure threshold setting instructions *⑨ Fault record viewing instructionsA/M bottom+down bottom simultaneously press for 1 second to enter Page 1: lnput UAB output Uab current lA fault statusPage 2: lnput UBC output Ubc current lB fault statusPage 3: lnput UCA output Ubc current lC fauilure status,press up and down to switch the page,A/M key to returm⑩ Fault record settingBecause only the information when the equipment fails in normal operation is stored,P2.4 will be set to 1 after saving,and it will also be set when the fault occurs again.No.data will be stored,You need to set P2.4 to 0 to save the information when the next failure occurs.(Recording information supports power-off save).⑪ Reverse phase and phase loss protection description When this function is turned on,the reverse ohase will only be detected once when the machine is turmed on.The phase sequence error lnput Voltage flashes and the phase loss detected in real time.No output voltage after protection.※lf any special type,please follow the instruction manual with the product.Chapter II installation and commissioning⑫ Wiring instructons and dimensions Rs485output voltage lnput voltageVoltage range:AC0-500V Power sampling input range 0-5Asupply AC 9-15V power 10W IC Ib Ia Uc Ub Ua UC UB UA A B Protection normally closed Protection nomally openBoost control Step-down control L or N input Maximum current 5A Please extemal insurance156mm 92mmBack view��Chapter II installation and commissioningFault diagnosis and maintenanceChapter III fault diagnosis and maintenance 1、Analysis of abnormal phenomena 2、Fault diagnosis ① Overview ② Fault diagnosis Phenomena Probable causeAfter turning on the power supply and setting the “emergency transfer switch” of the voltage stabilizer to “stabilizing”, the voltage stabilizer has no output.The voltage stabilizer cannot automati-cally switch to the mains output after an overvoltage or under voltage failure occurs.The voltage stabilizer cannot stabilize the voltage.The stabilizer cannot be turned on.When a fault occurs, first look for obvious damage and try to find out whether the fault is caused by the device itself or by the external environment (such as temperature, humidity, and load). Before deciding that your equipment is damaged, always check these external factors.This section only contains some simple fault diagnosis procedures. If the answer to the diagnosis is not very clear, or the information obtained is not sufficient to solve the problem, please refer to a professional or special maintenance station for processing After you enable the stabilizer, if it does not work normally, please do not rush to deter-mine that the stabilizer is malfunctioning. You may use following methods to solve theproblem.The phase sequence of the input power (reverse phase) is connected reversely or is missing phase The system detects that the input voltage is greater than ±10% of the rated voltage, and it is not allowed to automatically transfer to mains.1、The input power wiring is loose. Please check and tighten the power wiring. 2、The input voltage is greater than the voltage regulator range.Please check the input voltage.The "emergency transfer switch" is placed in the "bypass" position.Please place this switch in the "regulated" position.Fault diagnosis and maintenance3、Maintain Phenomenon descriptionProbable cause Solution The air switch in the regulator is not closed or damaged.The sampling transformer is damaged The control circuit board is damag Fuse blown① The voltage stabilizer is in a fault protection state ② The intermediate relay of the secondary circuit is damaged or the contactor on the main circuit is damaged Unable to bootUnable to stabilize switch on or replace the air switch.switch on or replace the air switch.① Check whether there are overvoltage, undervoltage and other faults ② Replace the corresponding components No output voltage ① Overview Correct maintenance, including preventive maintenance and remedial maintenance, is the key to optimal operation of the voltage stabilizer and will ensure a long service life of the equipment. Preventive maintenance includes some routines that are frequently performed. These procedures are used to prevent system failures and maximize operating efficiency. Remedial maintenance includes finding system failures for effective main-tenance. ② Safety precautions In order to perform system maintenance safely and successfully, the relevant safety precautions must be followed, the necessary tools and test equipment must be used, and qualified maintenance personnel must be involved. The following safety operat-ing procedures must be always observed:● Always remember that there is a dangerous voltage in the stabilizer, even if the stabilizer system is not running.Confirm that the voltage stabilizer operation and maintenance personnel must befamiliar with the equipment and the contents of this manual.● When operating the voltage stabilizer, do not wear gold or silver jewelry such as rings and watches.● Do not take the safety operation procedures for granted. If you have any questions, please consult the personnel familiar with the equipment.● Always be alert to the presence of dangerous voltage in the voltage stabilizer, and check with a voltmeter before maintenance and adjustment to ensure that the power is off and in a safe state.● Please strictly follow the user manual for use. When the voltage stabilizer fails, please do not handle it without authorization, and hand it to a professional or repair station.③ Preventive periodic maintenanceIn the process of use, regularly inspect the working status of the voltage stabilizer to check whether the temperature rise of the compensation transformer and the voltage regulating transformer is normal, whether the load exceeds the rated value, whether the input voltage exceeds the specifierange, whether the voltage regulating system and the transmission mechanism (including the transmission chain) work normally, whether the carbon brush holder is loose, whether the carbon brushes are on the same plane and in the same straight line, and whether the contact is good. None of the problems listed above is allowed to exist, so once it is found, it must be solved in time. If encounter difficult problems, you should notify the factory for solution in time to avoid damage to the equipment. It is recommended to maintain the voltage stabilizer every three months.The maintenance includes:● Eliminate dust and dirt from various parts of the stabilizer.● Check whether the electrical components are damaged, if damaged, they must be replaced in time.Fault diagnosis and maintenance上海市嘉定区高石公路 2439 号2439 Gaoshi highway, Jiading District, Shanghai邮政编码(Postal Code) 201816 传真(Fax):************网址(URL): 公司电话(TEL):************市场部电话(TEL):************-7后电话(TEL):800-820-3007产品说明书PRODUCT SPECIFICATION公司/上海稳利达电气有限公司 上海稳利达科技股份有限公司Company / Shanghai Wenlida Electric Co., Ltd. Shanghai Wenlida Technology Co., Ltd 印刷/上海视叶数码印刷有限公司Printing / Shanghai Shiye Digital Printing Co., Ltd 开本/148毫米×210毫米 32 开 印张/ 2 字数/ 5千Folio/148mm×210mm 32 open Printed Sheet/ 2 Words/ 5K 版次/2021 年 8 月第 1 版 2021 年 8 月第 2 次印刷Edition/First edition in August 2021 First printing in August 2021(如有设置、更换配件等需求可拨打以上任意电话联系,24小时服务)(If you need to set up or replace accessories, you can call any of the above numbers for 24-hour service)欢迎关注稳利达科技公众号2021年8月。
SBW-100KVA全自动补偿式交流稳压器的使用及维护
SBW-100KVA全自动补偿式交流稳压器的使用及维护摘要:为保证电压稳定,SBW系列三相全自动补偿式电力稳压器得到广泛使用,并展现颇多优势。
如果因为外界因素影响,或者负载发生变化导致电压波动大,可以借助稳压器增强电压的稳定性,提升设备的运行效率和安全性。
为深入了解此类型稳压器的使用情况,将SBW-100KVA全自动补偿式交流稳压器作为主要研究对象,明确了稳定器的应用特点和原理,并结合设备运行要求,对安装、使用、维护以及故障处理分别进行探讨,确保设备在使用过程中能将功能和作用发挥到最大。
关键词:SBW-100KVA;全自动;补偿式交流稳压器;使用及维护引言在当前社会生产生活中,如果电压缺乏稳定性,会导致设备老化,缩短设备的使用寿命,甚至需要频繁维修和保养设备,因此维持设备电压稳定至关重要。
SBW-100KVA全自动补偿式交流稳压器在维持电压稳定方面发挥重要作用,效率高且时效性强,能够为生产工作的开展提供交流稳压电源,促进生产效率的提高。
故而,应该强化对此类稳压器的研究与应用。
1SBW-100KVA全自动补偿式交流稳压器的应用特点和原理1.1 应用特点SBW-100KVA全自动补偿式交流稳压器的特点较多,诸如容量大、效率高,适用的负载相对广泛,可以承受瞬时超载,也达到连续工作的目的。
在稳压器运行阶段,手动、自动开关可以做到灵活切换。
并且此类设备在具体安装过程中,便利性强,对技术人员的要求不高,使用过程安全且稳定。
SBW-100KVA全自动补偿式交流稳压器的组成部分较多,诸如补偿电路、伺服电机控制电路、减速传动结构等。
为保证稳压器能平稳运行,在实际应用期间,需要对稳压器的工作原理明确掌握,注意应用规范和操作流程。
1.2 工作原理SBW-100KVA全自动补偿式交流稳压器是由多个部分组合而成,包括显示电路、操作电路、补偿系统等。
稳定器在具体运行阶段,工作原理具体如图1所示。
结合图1可以看出,主要由三相输入电压经过补偿电路、保护电路,最后输出电压,在此期间,电压检测补偿电路,而旁路系统则由补偿电路和保护电路构成。
单相全自动补偿式稳压器工作原理
单相全自动补偿式稳压器工作原理
单相全自动补偿式稳压器的工作原理主要通过自动调节输出电压来实现稳定供电。
当输入电压波动或负载变化时,补偿式稳压器可以自动检测并调整输出电压,确保其稳定在设定值。
这一工作原理是通过一个控制回路以及电子元件实现的。
在补偿式稳压器中,控制回路起着关键作用。
控制回路通过感知输出电压的变化,并将这些信息传递给补偿式稳压器的电子元件。
电子元件根据所接收到的信息,对输入电压进行调节,以维持输出电压的稳定。
同时,补偿变压器的低压侧线圈串联在稳压器的主回路中,这种稳压器输出的主要能量是通过补偿变压器的低压侧线圈直接加给输出负载的。
只要把补偿变压器的二次线圈的线径作得足够大,稳压器的功率就可以做得很大。
调压变压器T1只要负担输入电压与输出电压的差额部分,按稳压器可允许的输入变化范围的大小不等,调压变压器T1的功率大小往往是稳压器实际容量的几分之一,这由稳压器的配比这个参数来决定调压变压器的大小。
请注意,具体的工作原理可能因不同型号、不同制造商的补偿式稳压器而有所不同。
如果您需要更详细的信息或特定型号的稳压器的工作原理,建议查阅产品手册或联系制造商或专业技术人员。
DBW-SBW稳压器使用说明书
●响应时间短,可小于 0.5 秒; ●适用任意负载(阻性、感性与容性); ●可长期连续运行;
●有欠压、过压及故障保护;
●自动投入,(如电网停电,恢复供电后),经 5 秒延时后自动投入。
3、规格: 型号
SBW-20KVA SBW-30KVA SBW-50KVA SBW-80KVA SBW-100KVA SBW-150KVA SBW-180KVA SBW-225KVA SBW-320KVA SBW-400KVA SBW-500KVA SBW-600KVA SBW-800KVA SBW-1000KVA SBW-1600KVA DBW-20KVA DBW-30KVA DBW-50KVA DBW-100KVA DBW-150KVA DBW-200KVA DBW-250KVA
住“升压’’按钮使输出电压高于 425 伏时过压保护电路能自动切断电源。
c.按下“启动”按钮,然后点动“升压”或“降压”按钮,使碳刷滑动或滑道两端碰
撞限位开关时,应能可靠切断伺服电机电源,注意本试验应从速,以免输出电压过高引起
故障; (注:本项目出厂前已调试好,用户可不予调试)
d.将手动自动置于“自动”位置,输出电压应能自动调整到稳压精度范围内。
输入电压(伏)
304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 304-456 176-264 176-264 176-264 176-264 176-264 176-264 176-264
2800
380
2430
3500
220
SBW三相电力补偿式稳压器
SBW三相全自动电力补偿式稳压器上海黎茂电器设备制造有限公司SBW、DBW系列补偿式交流电力稳压器(以下简称稳压器),是我厂引进,吸收国内外先进技术,同时结合我国国情,为稳定交流电压而设计的,当外界供电网络电压波动或负载变化造成电网波动时能自动保持输出电压的稳定.本系列产品与其它形式稳压器相比较具有容量大、效率高、无波形畸变、电压调节平稳,适用负载广泛,能承受瞬时超载可长期连续工作,手动、自动随意切换,并设有过压、欠压、过流、相序保护、机械故障自动保护装置,以及体积小、重量轻、使用安装方便,运行可靠等特点.可广泛应用于工业、农业、交通、邮电、军事、铁路、科研文化等领域的大型机电设备、金属加工设备、电梯、医疗器械、微机机房、电脑控制设备、刺绣轻纺设备、空调广播电视及家用电器照明等一切需要稳压的场所。
使用条件SBW、DBW系列稳压器应在室内使用,正常使用条件为:1。
环境温度:-15℃~+45℃;2.海拔高度不超过1000m;3。
相对湿度:≤90%;4.安装场所应无严重影响稳压器绝缘的气体蒸气化学积尘灰尘污垢及其它爆炸性和浸蚀性介质;5.安装场所应无严重振动和颠簸;6。
凡不符合上述规定的特殊使用条件,应有使用单位我厂协商确定。
结构它由三相补偿变压器、三相接触调压器、传动机构、电刷接触系统、箱体和电气控制系统组成。
三相接触调压器柱式绕组外表面经车床打磨加工,去除绝缘层呈光滑的导电体,以便于电刷平稳接触;传动机构由电动机和蜗轮、蜗杆、链轮、链条组成;电刷系统结构合理可靠,以保证电刷压力;体积小,散热好,检测仪表位置醒目,指示准确。
型号规格产品尺寸、重量整机及主要部件工作原理主要部件与电路三相主电路开关装置及操作电路1)。
稳压器主电路设置了一只电控开关QA和一只刀形开关QN。
是为了使电压自动补偿系统能方便地投入和退出而设置的,投入运行时只要把刀形开关QN置于“稳压"状态,按“稳压”按钮,电控开关QA就能自动合上即可:假如稳压器自身出现故障或需要在市电直通状态下使用,只要把刀形开关手柄置于“市电"位置即可,并按下“停止"按钮,使市电指示灯亮。
正泰稳压器功能介绍
正泰稳压器功能介绍一:TND1/ TNS1(SVC)系列高精度全自动单、三相交流稳压电源TND1/ TNS1(SVC)系列高精度全自动单、三相交流稳压电源TND1/TNS1(SVC) 系列全自动交流稳压电源是由接触式调压器及自动控制电路组成。
对电压信号进行取样、放大再控制伺服电机带动转臂及电刷按所需方向转动,使输出电压调整到额定值而达到稳压目的。
性能指标完全符合JB/T 10089标准。
该稳压电源具有外型美观大方、体积小、重量轻、自身功耗低、各种保护功能齐全、稳定可靠、输出波形失真小的特点。
可广泛应用于工业生产、科学研究、医疗卫生、家用电器等电网电压波动大或电网电压季节变化大的地区,能给任意负载提供优质电源。
二:TNDZ(DBW)/TNSZ(SBW)系列补偿型柱式交流自动稳压器TNDZ(DBW)/TNSZ(SBW)系列补偿型柱式交流自动稳压器TNDZ(DBW)/TNSZ(SBW)系列补偿型柱式交流自动稳压器分为单相TNDZ(DBW型)、三相(SBW型)二种,与其它形式稳压器相比具有容量大、效率高、电压调节平稳,适用负载广泛,能承受瞬时超载,可长期连续工作,手控自控随意切换,设有过压、短路保护功能,使用安装方便,运行可靠等特点。
可广泛应用于工业、农业、交通、邮电、军事、铁路、科研文化等领域的大型机电设备、金属加工设备、生产流水线,建筑工程设备、电梯、医疗器械、微机机房、电脑控制设备、刺绣轻纺设备、空调、广播电视、宾馆及家用电器照明等需要稳压的场所。
三:TND2系列高精度全自动交流稳压电源TND2系列高精度全自动交流稳压电源TND2系列高精度全自动交流稳压电源是本公司自行研制的第二代产品,由接触式调压器,自动控制电路进行取样、放大、控制伺服电机带动转臂、电刷按所需方向转动,使输出电压调整到额定值而达到稳压目的。
该稳压电源面板以LED中文显示,具有延时输出、过压、欠压保护,以及负载模拟量显示及过载报警;外型美观大方、体积小且厚度薄、重量轻、自身功耗低、稳定可靠、输出波形失真小的特点。
SBW-S_说明书
SBW-S 型微机控制补偿式交流稳压器操作手册上海华润特种变压器成套有限公司【敬请周知】操作之前,请详细阅读使用手册,以了解设备正确的使用方法。
阅毕请妥善保存,以便日后查考。
1.连接设备前必须先保证设备可靠接地。
2.本设备的输入、输出电压为危险的高压,会危及人的生命安全。
3.请勿自行打开设备外盖,有触电危险。
4.任何紧急情况下,先断开电源输入开关。
5.该设备必须由专业人员安装和维修。
6.此为电磁兼容A级产品。
7.如有问题请咨询经销商专业人员或特约维修站,不要擅自处理。
目录1、概述 (1)1.1 公司介绍 (1)1.2 型号含义说明 (1)1.3 产品简介 (1)1.3.1 产品特点 (1)1.3.2 技术指标 (2)2、基本原理和结构 (3)2.1 基本原理 (3)2.1.1 原理框图 (3)2.1.2 工作原理及面板操作 (3)3、运输和储存 (6)3.1 运输 (6)3.2 储存 (6)4、安装 (7)4.1 安装注意事项 (7)4.2 现场和环境要求 (7)4.2.1 现场要求 (7)4.2.2 环境要求 (8)4.3 拆箱 (8)4.4 检查电源 (8)4.5 主机安装 (9)4.6 电气连接 (9)4.6.1 电缆的选择 (9)4.6.2 电缆的连接 (9)4.7 系统检查和测试 (10)4.7.1 电气连接检查 (10)4.7.2 稳压器测试 (10)4.8 连接负载 (11)5、使用 (12)5.1 使用注意事项 (12)5.2 开机前准备工作 (12)5.3 开机顺序 (12)5.4 关机顺序 (12)6、维护指南 (13)6.1 故障诊断 (13)6.1.1 非故障异常现象分析 (13)6.1.2 故障诊断 (14)6.2 维护 (15)6.2.1 概述 (15)6.2.2 安全预防措施 (15)6.2.3 预防周期性维护 (15)6.3 参数设置 (17)6.3.1 概述 (17)6.3.2、参数设置 (17)6.3.3、部分参数设置举例 (19)6.3.4、参数一览表 (20)1、概述1.1 公司介绍华润公司是各类大功率稳压器、变压器的专业生产制造商,是集研究、开发、生产、销售和服务于一体的业界龙头企业和高新技术企业,拥有国际权威机构认可的ISO9001国际质量标准管理体系。
三进三出系列UPS电源的工作原理与调试维护
UPS容量一定时,设计时应尽可能让电池电压最低,这样UPS电池寿命就 越长,对于电池电压一定时,应选择数量少电压高原电池串联的电池,不要选 择数量多电压低的原电池串联的电池。有些厂家UPS的电池电压比较高,这是 因为容量一定时, 电压越高,电流就越小,就可选用较细的导线和功率较小 的半导体, 从而降低UPS成本。容量1KVA左右的UPS的电池电压一般24V或 96V。 在UPS十年的使用期里,更换电池的成本比UPS本身售价高出两倍!虽 然这类UPS设计比较容易,成本也较低, 但“潜在的”更换电池则成本很高。 电池纹波电流影响电池可靠性。理想情况下,为了延长UPS电池寿命, 应让 电池总保持在“浮”充电或恒压充状态。这种状态下充满电的电池会吸收很小 的充电器电流,它称为“浮”或“自放电”电流。尽管电池厂商如此推荐,有 些UPS的设计(很多在线式) 使电池承受一些额外的小电流,称为纹波电流。纹 波电流是当电池连续地向逆变器供电时产生的,因为据能量守恒原理,逆变器 必须有输入直流电才能产生交流输出。
备注
影响UPS寿命的一些因素
即使UPS使用的是同样的电池技术,不同厂家的电池寿命大不一样, 这一 点对用户很重要,因为更换电池的成本很高(UPS售价的30%)。 电池故障会减 小系统的可靠性,是非常烦人的事情。电池温度影响电池可靠性温度对电池的 自然老化过程有很大影响。详细的实验数据表明温度每上升摄氏5度,电池寿命 就下降10%,所以UPS的设计应让电池保持尽可能低的温度。所有在线式和后 备/在线混合式UPS比后备式或在线互动式UPS运行时发热量要大( 所以前者要 安装风扇),这也是后备式或在线互动式UPS电池更换周期相对较长的一个重要 原因。APC UPS电池的温度降到最低了,所以它能更好地满足系统可靠性要求。 电池充电器设计影响电池可靠性电池充电器是UPS非常重要的一部分,电池的 充电条件对电池寿命有很大影响。 如果电池一直处于恒压或“浮充”型电池充 电状态,则UPS 电池寿命能最大程度提高。
DBW SBW稳压器使用说明书
特点与用途
SBW 系列全自动三相大功率电力稳压器(以下简称稳压器),是引进最新技术制造的新 一代节能稳压器。它具有容量大、损耗低、效率高稳压范围宽、精度高、保护功能强、体 积小、重量轻、运行可靠、使用维护简便等特点。
该系列稳压器已广泛用于工矿企业、邮电、油田、铁路、建筑工地、学校、医院、宾 馆、国防、科研等部门的电子计算机,精密机床、精密机器、试验装置、电梯、进口设备 及生产流水线上。同时也适用于电源电压过低或过高,以及波动幅度大的低压配电终端用 户与负载变动大的用电设备,如升降机、搅拌机等,可为一切需要电压稳定的设备和场所 提供一种最理想的优质交流稳压电源。
型号、性能指标与规格
稳压范围:是指保证稳压器输出电压在精度允许范围内输入电压的变化范围。通常稳压范 围为±20%,即输入电压的变化范围 304~456 伏。
例:一台容量为 100 千伏安的三相交流稳压器,允许输入电压变化范围为 304~456 伏,则其型号为 SBW-100KVA。 2、性能指标:
●稳压范围宽,可稳定 304~456 伏; ●波形失真小; ●稳压精度高,380 伏±3%; ●输入和输出电压同相位; ●调节性能好,实现无级调节; ●效率高,可达 98%以上;
图二 当输入电压 UAi 变化或者由负载扰动而引起输出压 UAO 变化时,则检测电路从稳压 器输出端取得采样信号,而给出控制指令使伺服电机驱动碳刷在调压器线圈表面作往复滑 动,调节其输出电压的大小,从而改变了补偿变压器的补偿电压△U 的方向和大小,以实 现自动保持输出电压 UAO 的稳定不变。
一4一
QUERLI
SBW (DBW)-系列 三相(单相)大功率补偿式电力稳压器
使用说明书
QUERLI 中国·上海全力电器有限公司
SBW DBW说明书
稳压器由补偿电路、控制电路、伺服系统及控制回路组成,其电气原理接线框图如图一 :
4 DBW、SBW系列
CJ1
CJ2
CJ3
输
补偿电路 入
接触器操作电路
伺服系统
电压检测
图一 SBW 自动补偿三相交流稳压器原理接线框图
输 出
保护电路
电压补偿原理见图二,由接触调压器 B 与补偿变压器 C 组成。接触调压器连接在稳压器的输出端,
压器圆柱线圈滑动,平稳的调节输出电压。 3、控制电路 控制电路包括电压检测,伺服电机控制,保护电路组成。调压控制电路以两组双限比较器为核心而组 成,其输入从稳压器输出电源采样,经处理之后得到误差信号。该信号经放大后驱动伺服电机,伺服电机带 动电刷运动,从而达到稳定输出电压的目的。有关保护功能详细过程见图三。
DBW-3
3
220
14
DBW-5
5
220
23
DBW-10
10
220
46
DBW-20
20
220
91
DBW-30
30
220
137
DBW-50
50
220
228
DBW-100
100
220
455
注 : 特殊规格可根据用户需要定做
大功率自动补偿式电力稳压器 3
三、使用条件
稳压器户内的正常使用条件: 1、环境温度 : -25℃ ̄40℃ 2、海拔高度 : 不超过 1000 米; 3、相对湿度 : RH90% 25℃ 4、安装场所无严重影响稳压器的气体,蒸气、化学性沉积、灰尘、污垢及其它爆炸性和浸蚀介质; 5、安装场所应无严重振动或颠簸。
补偿变压器二次侧串联在主回路中。
电源稳压器维修方法
电源稳压器维修方法电源稳压器可以说是一种十分有效又安全的电器辅助设备,应用范围十分广泛。
不过它在是一个过程中,由于各种原因,难免会出现一些问题。
下面就是店铺为大家整理的电源稳压器的常见故障以及维修方法。
电源稳压器维修方法一、开机时,电压表不指示故障原因1、电源插头没插紧,电压没有输出。
2、保险丝断了。
维修方法1、检查一下电源插座,把电源插头插牢。
2、检查保险丝,按照要求更换符合规定的保险丝。
二、稳压器能够稳压,但是稳压值偏移故障原因1、电压表读取的数值不准确2、电压微调电位器移位了。
维修方法1、检查一下电压表,视情况维修或者更换它。
2、将电压微调电位器进行正确的调节。
三、稳压线圈烧坏故障原因稳压器的负载太大,已经超过了稳压器的正常负荷范围。
维修方法更换稳压线圈。
在更换的时候要注意调节电压以及线圈的安装位置,如果不能正确操作,即使换上了线圈,也会再次烧坏。
四、接上稳压器后断路器开关跳闸故障原因1、稳压器的输入线接错了。
2、高分断断路器开关额定电流不对。
维修方法1、检查稳压器的输入线,将其正确接好。
2、更换合适的高分断断路器。
五、输出电压表不停的来回摆动而且碳刷处还会产生火花故障原因1、碳刷严重磨损。
2、碳刷与稳压线圈的平面接触压力太小。
维修方法1、更换新的碳刷。
2、用细锉刀或者砂纸把碳刷和稳压线圈处理干净,然后调整碳刷的压力。
六、三相不启动,没有输出电压故障原因1、控制线路板不工作。
2、控制线路板处在保护状态。
3、输入缺相。
维修方法1、控制线路板不工作一般是掉线或者自身损坏了,需要修复或者更换。
2、控制线路板在保护状态,一般是输入相线电压超出了稳压范围,只要调整输入电压即可。
3、正确输入三相,应该是三相四线制或五线制。
电源稳压器分类LW-SBW补偿式基本结构:采用电机带动碳刷在自藕变压器绕组匝间滑动而直接调节输出电压或通过补偿变压器调节输出电压。
技术指标:输入范围:单相176V-264V/三相304V-456V 频率:47HZ-63HZ输出额定:相电压220V,线电压380V 中心电压值调节范围±8%稳压精度:±(1-5)% 常规设定为±2% 响应时间快(一个电源周波200ms)电压:指针显示电流:指针显示工作状态:稳压状态/市电状态异常:过压、欠压、过载、保险丝断工作方式:具有稳压和市电两种工作方式过载能力:4 倍额定电流2 秒钟LW-SVCE 高精度稳压器基本结构:该系列稳压器是由接触式自耦变压器、伺服式电动机、自动控制电路等组成,当电网电压不稳定或负载变化时,自动采样稳压器控制电路发出信号驱动伺服电机,调整稳压器自耦调压器碳刷的位置,使稳压器输出电压调整到额定值并达到稳定状态。
人民电器 DBW、SBW系列交流稳压器 使用说明书
D B W(S B W)系列全自动补偿式电力稳压器符合标准:J B/T8749.8警告1 三相SBW稳压器必须接入零线即三相四线才能工作,严禁用地线代替零线,或不接零线。
通电后应使用电压转换开关,观察三相电压均正常方可投入运行。
2 为了确保设备和人身安全,自动稳压器外壳均设有接地螺钉或接地端子,安装时务必接好地线。
3 安装、接线、调整等带电工作,必须由电工来操作,避免在接线,调整时触电或损坏稳压器。
注意1 输入电压在允许范围内,输出电压不稳定应进行检查(见故障原因与排除),输入电压稍超出允许范围,输出电压的改变若对用户影响不大,适当降容可继续运行。
当输入电压返回到允许范围内,输出电压能自动保持稳定。
2 常规型号的稳压器没有独立的分相控制与调节功能,如输入电压三相不平衡(超出额定值±4%)或使用负载造成三相电压不平衡时,需采用分相调压补偿式稳压器SBW-F型号。
3 当输入电压值小于额定值的90%时,输出端负载应随输入电压的降低而减少,输入电压为下限时,使用负载为额定容量的60%(为纯阻性负载时)。
1 概述DBW、SBW系列全自动补偿式电力稳压器(以下简称稳压器)是我集团公司采用国际先进的补偿式技术,同时结合我国电力系统的国情而设计制造的,当电网电压波动或负载变动而造成电压波动时能自动保持输出电压的稳定。
稳压器具有容量大、效率高、电压调节平稳、无波形畸变,适用负载广泛,可长期连续工作,自动、手动随意切换,使用方便等优点,可广泛用于工业、农业、邮电、通讯领域的大型机电设备等一切需要稳压供电的场所。
本产品按JB/T7620标准设计、制造与检验。
2 产品特点2.1 具有开机延时功能在稳压状态运行时,按稳压按钮,稳压器开机调整到稳压额定值时(几秒钟),才有输出电压供用电设备。
2.2 具有输出过电压保护与报警功能在稳压状态,当输入电压大大超出输入电压范围(304V~456V)或其他原因致使稳压器的输出电压出现过电压(426±7V)时,稳压器切断电源并报警,当输出电压降低时,自动恢复工作。
稳压器选型方法
稳压器选型指南一、对稳压器标称容量的理解交流稳压电源是以输出视在功率(电流和电压的乘积kVA)为标称额定容量,而不是有功功率kW。
一般情况下负载都不是纯电阻性的,即功率因数COS¢≠1,稳压器实际能输出的有功功率kW=容量(kVA)×COS¢(小于1)。
所以在实际选型时要按用电设备的额定功率、功率因数和负载类型等具体情况来合理选择稳压电源,其输出功率应留有适当余量,特别是冲击性负载选型时余量要更大。
另外稳压器输出功率和输入电压有密切关系,当输入电压单相低于200V、三相低于350V时稳压器功率将减小,输入电压越低输出功率越小,最低电压输入时功率减半使用。
二、稳压器的功率选择具体选型时要考虑负载性质(阻性,容性,感性)、设备类型(动力,单个负载大小,照明,电热等)、输入电压高低、安全系数等因数来选择稳压电源容量。
1、纯阻性负载白炽灯、电阻丝、电炉等设备 1.25~1.5倍负载总功率。
2、感性、容性负载、荧光灯具、风机、小电动机、小水泵、空调、电脑、电冰箱等应≥2~3倍负载总功率。
3、大电感性、电容性负载(如大功率电动机、多台电脑)环境下,选型时应考虑负载的起动电流特别大(达额定电流的5~8倍),所以选择稳压器容量时应是负载功率的3~4倍。
如果稳压器工作在输入电压下限,则所选的稳压器功率还要加倍。
自耦式稳压器能够同时输出220V和110V两种电压。
但即使是全部由110V输出时,稳压器所带负载也不能超过额定容量的50%,否则就是过载使用。
三、不同场合选用不同的稳压器工矿企业、酒店宾馆等用电量大的单位选用SBW补偿式电力稳压器;民用或小用电量单位选用DJW、SVC单相、SJW三相全自动稳压器;精密仪器、数控电脑等要求电压稳定应选用高可靠性的精密净化电源。
稳压器适用范围:稳压器可广泛应用于工矿企业、油田、铁路、建筑工地、学校、医院、邮电、宾馆、科研等部门的电子计算机、精密机床、计算机断层扫描摄影(CT)、精密仪器、试验装置、电梯、照明、进口设备及生产流水线等需要电源稳定的场所。
SBW系列稳压器的原理与维护
SBW系列稳压器的原理与维护摘要:目前广播电视发射台普遍使用数字调制固态发射机作为发射设备,由于固态发射机对供电电源电压要求较高,因此各台都采用稳压电源供电,由于SBW系列补偿式稳压器具有效率高、容量大、稳压范围宽、抗高频感应能力强等优点,广泛用于各广播发射台站,为此做好稳压器的维护、保养工作是确保安全播出的重要内容之一。
本文根据笔者在实际工作中的一此体会,阐述SBW系列稳压器的稳压原理与它的日常维护保养。
关键词:稳压器;缺相和相序保护;取样检测1稳压器的组成SBW系列补偿式交流稳压器由:补偿变压器、带有滑动触点的接触调压器、伺服驱动机构、控制系统、取样检测系统、保护系统组成,其原理框图见图(一)(图中只画出了一相电路,其它两相电路相同)。
图中,ZK为空气开关;JC为交流接触器;K为稳压、非稳压转换开关;T1、T2组成调压系统。
T1为接触调压器,有两组可以反向移动的电刷,利用电刷接触位置的变化,使其输出电压的大小和极性都发生变化。
T2为补偿变压器,通过改变一次线圈上所加电压的大小和极性,使串联在负载回路上的二次线圈产生幅值和极性可变的补偿电压。
2稳压工作原理稳压原理见图(二),图中Uin为输入相电压,Uout输出相电压,Uo为稳压器补偿电压。
当输入电压Uin改变或因负载变化,使其输出电压Uout改变Uo 时,通过取样和伺服系统使T1上的电压发生变化,此变化的电压送到T2的一次线圈,在T2的一次线圈上感应出补偿电压Uo,若使变化的电压值等于补偿电压且相位相反,则输出电压可保持不变,达到稳压的目的。
若忽略补偿变压器线圈的阻抗,则其输出电压为:Uout=Uin±Uo3缺相和相序保护原理从补偿变压器输出端T2取出的三相电压分别接到C、R1、R2上(见图三),由电工学原理可知,当缺相和相序错误时,接在三相电源中的不对称负载的中性点将发生位移,两只电阻两端将承受相差很大的电压,设R1=R2=XC,则当为顺相序时,R1和R2上的电压为:UR1=(-0.3-j1.466)U相UR2=(-0.3+j0.266)U相有效值分别为:UR1=1.5U相UR2=0.4U相为逆相序时:UR1=(-0.3+j0.266)×U相UR2=(-0.3-j1.466)×U相其效值为:UR1=0.4U相UR2=1.5U相利用这一原理,当缺相和相序错误时,在R1、R2上的电压变化来控制电压窗口比较器,使稳压器停止工作。
无触点稳压器安装使用说明书
DBW/SBW-T型补偿式无触点交流稳压器陕西四方华能电气设备有限公司公司简介陕西四方华能电气设备有限公司(简称四方华能),专业从事改善电网电能质量和节能降耗智能化电气设备的研发、生产和销售的高新技术企业。
公司拥有自主知识产权,先后推出的调压类装置、高低压无功自动补偿类装置、高低压滤波装置等,较好解决了电力系统中电压、无功、谐波等电能质量问题。
公司始终以“科技领先、质量第一、客户至上”的服务理念,一直将科技创新、高效运营、严格质量控制盒精心的客户服务作为企业发展的一大环节。
公司已完全具备满足市场需求的产品设计开发能力和先进的生产设备、检测试验设备以及精湛的生产工艺。
公司通过ISO9001:2008质量管理体系认证。
产品经国家高压电器产品质量监督检验中心、国家电器产品质量监督检验中心检验合格。
公司凭借先进的技术和生产经验,采用电力电子技术,研制成功专利产品DBW/SBW-T型无触点补偿式免维护电力稳压器,率先填补了国内无触点电力稳压器的空白。
产品无机械、无碳刷,响应速度极快,容量高达2000KVA,补偿范围可达±50%。
经中科院情报中心确认,该产品多项技术属国内外首创,其整体技术达到了国际同类产品的先进水平。
一、工作原理图1_三相无触点稳压器原理框图T型无触点稳压器主要由补偿电路、调压电路、控制电路、输入采样电路、输出采样电路、输出控制电路、保护电路、旁路电路等单元组成。
其工作过程为:当输入电压波动或负载变化时,通过各采样电路获取反馈电压,经与基准电压进行比较判断,然后由控制电路输出控制信号,控制调压电路中相应的晶闸管导通,使补偿电路产生极性和大小不同的补偿电压,达到稳定输出电压的目的。
同时,控制电路还对保护电路和输出控制电路进行控制,产生相应的动作。
T型无触点稳压器的主要电路是补偿电路和调压电路,其简图如下:图2_无触点稳压器的补偿和调压电路补偿和调压电路的工作过程为:当输出电压Uo高于额定值时,要求补偿变压器T1上的补偿电压△U抵消升高的那部分电压,此时可触发S5和S8可控硅导通,交流正半波时电流通路为:A—T1上绕组—T2—S5—T1下绕组—S8—N,交流负半波时电流沿上述通路反向流动(由于使用了双向可控硅)。
浅谈SBW系列三相全自动补偿式电力稳压器使用与维护
许泄漏率 的 1% . 因 此 电 缆 贯 穿 件 允 许 泄 漏 率 为:
/h
2
7
5
8×1%=0
2
7
5
8kg
转换为体积流量为:
/
考虑安全壳老化
0
2
7
5
8
1
2
9
3=0
2
1
3
3m /h,
系数 为 0
7
5,电 缆 贯 穿 件 总 体 允 许 泄 漏 率 为:
0
2
1
3
3×0
7
5=0
1
6
0m3/h
2018-12-01
102
表头有输出指示,而输出端
子没有
按启动按钮有输出,
放掉没
有输出
按启动按钮无反应
a、控制线路板坏
b、采样变压器坏
c、输出电压调节器坏
CJ3 交流坏
CJ2 交流坏
a、CJ4 交流坏
b、零线未接好
c、CJ5、CJ1、CJ3 其中有一个常闭辅助坏
2.
2 接线
电源接到输入接线端,
3
该泄漏率转化为:
LOCA 工况下,
3
/
0
1
6
0m /h× (
1
4
5+2
7
3)
2
7
3=0
2
4
5
0m3/h
,低 压 电 缆 贯 穿
根据«
电缆贯 穿 件 技 术 规 格 书 »
件的容 积 是 0
0
5
7m3 ,中 压 电 缆 贯 穿 件 的 容 积 是
其
0
2
1
DBW-JW_SBW-JW工业级无触点智能稳压器
本系列工业级无触点智能稳压器分为单相DBW-JW 、三相SBW-JW 两种,与其它形式稳压器相比具有电压调节响应时间快、稳压精度高、无触点无机械磨损等特点,产品采用DSP 运算计量芯片控制技术、快速交流采样技术、有效值校正技术、电流过零切换技术和快速补偿稳压技术,并设有过压、欠压、过流等保护功能。
适用于通信机房、试验或化验仪器设备。
符合标准:YD/T 1270。
DBW-JW 、SBW-JW 工业级无触点智能稳压器正泰-智慧能源解决方案提供商 l 376互感器、稳压器类□B W -J W -□微机控制无触点调节稳压器补偿式相数:D为单相,S为三相额定容量,kVA3.1 液晶显示:实时显示电压、电流值,人性化人机操作界面。
3.2 三相分调,输出电压不平衡度小于1%,无触点、无磨损、免维护。
3.3 高速反应:稳压响应时间在40毫秒以内,对电脑自动化、设备及仪器,不产生电压变化影响。
3.4 高精度:产品输出电压精度±1%~±5%可设定, 最高稳压精度为±1%。
3.5 保护功能齐全:设有过载、过压、欠压、短路等故障显示和保护功能。
3.6 预置功能强:过流保护限值可以任意设定。
3.7有旁路功能,易维护:可在“稳压”与“旁路直通供电”之间切换,方便故障维修时使用。
377 l 正泰-智慧能源解决方案提供商配电电器5.1 安装环境周围空气温度上限值为+40℃,且其24h内的平均温度值不超过+35℃。
周围空气温度下 限值为-5℃。
5.2 安装地点的海拔不超过2000m(大于2000m时须降容使用)。
5.3 最高温度为+40℃时,空气的相对湿度不超过+50%,在较低的温度下可以允许有较高的相对湿度。
例如20℃时达90%。
对由于温度变化偶尔产生的凝露应采取特殊的措施。
5.4 户内使用,应通风良好,无明显污秽、腐蚀性气体、粉尘、可燃物和可燃气体。
5.5 水平安装,无显著摇动和冲击振动。
5.6 稳压器间的输出端不能并联使用。
德力西电气 SBW 系列三相大功率补偿式电力稳压器样本 产品说明书
该产品是由柱式接触调压器、取样、保护、控制电路,低速同步电机机构,补偿变压器
等主要部分组成
当市电电压不稳或用户负载变化引起的波动时,取样电路将电压信号经处理送同步电机,
使其带动柱式接触式调压器碳刷上下移动,保证输出电压的稳定
它具有容量大、损耗低、效率高、稳压范围宽、精度高、保护功能强、运行可靠等优点。
并设有缺相、过压、欠压及过流保护功能
■ 产品特征
注:以上尺寸、重量仅供参考,如有改进恕不另行通知!
■ 接线图
G 电源类产品
G 电源类产品。
SBW有触点交流稳压器的原理与操作
SBW 有触点交流稳压器的原理与操作一、工作原理SBW 系列稳压器由三相补偿变压器TB 、三相调压变压器TVV 、电压检测单元、 伺服电机控制与传动机构、接触器(或断路器)操作电路、保护电路等组成。
其 电气原理图如图11.6.1所示。
二次绕组连接补偿变压器TB 的一次绕组,而补偿变压器的二次绕组串联在主回路中。
现以A 相为例,说明其稳压工作原理,如图11.6.2所示,若不计补偿变压器阻抗压降,则从图11.6.2可见:图11.6.2 补偿变压器工作原理图图11.6.1 三相稳压器主回路电气原理图U ao =U ai +U Ba式中 U ai 为稳压器A 相输入电压、U ao 为稳压器A 相的输出电压、U Ba 为稳压器A 相的补偿电压;其工作原理是:当A 相输入电压U ai 增加△U ai 时,补偿电压U Ba 也相应改变△U Ba ,且△U Ba =- △U ai 使A 相输出电压U ao 保持不变,同理B 相、C 相也相同。
其稳压过程是:根据输出电压的变化,由电压检测单元采样,检测并输出信号控制伺服电机M 转动,带动调压变压器TVV 上的电刷组滑动(或滚动),调节调压变压器的二次电压,以改变补偿变压器的极性和大小,实现输出电压自动稳定在稳压精度允许的范围内,从而达到自动稳压的目的。
其控制线路版图如图11.6.3。
二、安装与操作 (一)安装接线将稳压器输入电源线接入柜内的输入接线端子排上(上标有输入接线字样);将负载线分别接入到稳压器输出接线端子排上(上标有输出接线字样);中性线N 接到接零线柱上,(标有接零线字样)其线径由用户根据不对称程度酌定,但一般不小于6平方毫米。
对三相分调式稳压器,系统中线连接的可靠性要求很高,因此应十分重视系统中性线截面积的选择,应尽量减少导线连接的接触电阻,以免影响稳压器的正常工作。
接地线线规按当地供电部门有关规定执行,接地线应接至机柜内标有“接地线”的桩头上,接地电阻应小于4欧姆。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
产品介绍:中国著名品牌--YING SHI DAN牌
SBW、DBW系列单、三相全自动补偿式电力稳压器是适用于当外界的供电网络电压波动或负载变化而造成电压波动时,能自动保持输出电压稳定。
本系列产品与其它型式的稳压器相比,具有容量大、效率高、无波形畸变、电压调节平稳等优点,适用负载广泛,能承受瞬时超载,可长期连续工作,手动/自动切换,设有过压保护、缺相、相序保护及机械故障自动保护,本机体积小,重量轻,使用安装方便,运行可靠等优点。
(分数显、仪表指示两类)
适用范围:
广泛运用于工矿企业、印刷、机床、邮电、铁路、建筑工地、学校、医院、宾馆、国防、科研等部门的电子计算机、精密机床、精密仪器、实验装置、电梯及生产流水线的电源稳压中。
同时也适用于电源电压低、波动幅度大的低压配电终端用户及负载变动较大的用电设备,如升降机、起重机、搅拌机等一切需要电压稳定的场所。
该系列稳压器应在室内使用,正常使用条件为:环境温度:-15℃~+45℃ 海拔高度不超过1000m 相对适度:≤90%安装场所应无严重影响稳压器绝缘的气体,蒸汽,化学沉积,灰尘,污垢及其他爆炸性和侵侵蚀性介质;安装场所应无严重振动或颠簸凡不符合上述规定的特殊使用条件,应由使用单位和我厂协商确定。