人工晶体因素对后囊混浊的影响研究进展
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
co mpart m ent syndr o me[J ].Trans plant Pr oc,2006,38(3):833-835.
[6] Quintel M,Pel osi P,Cair oni P,et al .An increase of abdo m inal
p ressure increases pul m onary ede ma in oleic acid induced lung injury[J ].Am J Res p ir Crit Care Med,2004,169(4):534-541.[7] ErtelW ,Oberholzer A,Platz A,et al .I ncidence and clinical pattern
of the abdo m inal co mpart m ent syndr o me after “da mage -contr ol ”lapar ot o my in 311patients with severe abdo m inal and /or pelvic trauma[J ].Crit Care Med,2000,28(6):1747-1753.
[8] Loi P,De Backer D,V incent JL.Abdo m inal co mpart m ent syndr ome
[J ].Acta Chir Belg,2001,101(2):59-64.
[9] Tal R,Lask D M,Keslin J,et al .Abdo m inal co mpart m ent syndr o me:
ur ol ogical as pects[J ].BJU I nt,2004,93(4):474-477.
[10] Joynt G M,Ra m say S J,Buckley T A,et al .
I ntra 2abdo m inal
hypertensi on 2i m p licati on for the intensive care physician [J ].Ann
Acad Med Singapore,2001,30(3):310-319.
[11] Schaefer M,Saegesser H,Reichen J,et al .A lterati ons in
he modyna m ics and hepatic and s p lanchnic circulati on during lapar oscopy in rats[J ].Surg Endosc,2001,15(10):1197-1201.
[12] K otza mpassi K,Para mythi otis D,Eleftheriadis E .Deteri orati on of
visceral perfusi on caused by intra 2abdo m inal hy pertensi on in p igs ventilated with positive end 2ex p irat ory p ressure [J ].Surg T oday,2000,30(11):987-992.
[13] Pottecher T,Segura P,Launoy A.Abdo m inal co mpart m ent syndr ome
[J ].Ann Chir,2001,126(3):192-200.
[14] Varela JE,Cohn S M,Giannotti G D,et al .Near 2infrared s pectr oscopy
reflects changes in mesenteric and syste m ic perfusi on during abdominal co mpart m ent syndr o me [J ].Surgery,2001,129(3):363-370.
[15] Chen RJ,Fang JF,Chen MF .I ntra 2abdo m inal pressure monit oring
as a guideline in the nonoperative manage ment of blunt hepatic trau ma[J ].J Trau ma,2001,51(1):44-50.
[16] Escorsell A,Gines A,L lach J,et al .I ncreasing intra 2abdominal
pressure increases pressure,v olu me,and wall tensi on in es ophageal varices[J ].Hepat ol ogy,2002,36(4):936-940.
[17] Engu m S A,Kog on B,Jensen E,et al .Gastric t ono metry and direct
intra 2abdo m inal pressure monit oring in abdo m inal co mpart m ent syndr o me[J ].J Pediatr Surg,2002,37(2):214-218.
[18] Polat C,Aktepe OC,Akbulut G,et al .The effects of increased intra 2
abdo m inal p ressure on bacterial transl ocati on [J ].Y onsei Med J,2003,44(2):259-264.
[19] Hut ′an M,Salapa M,Vandriakova R,et al .Rupture of the
lapar ot omy incisi on and its suture usingVentr ofil m [J ].Rozhl Chir,2001,80(3):124-127.
[20] B l oo mfield G L,R idings PC,B l ocher CR,et al .A p r oposed
relati onshi p bet w een increased intra 2abdo m inal,intrathoracic,and intracranial p ressure[J ].Crit Care Med,1997,25(3):496-503.
[21] Moult on RJ.Abdo m inal co mpart m ent syndr o me in the head injured
patient[J ].Crit Care Med,2001,29(7):1487-1488.
[收稿日期]2007209204
[作者单位]安徽医科大学第一附属医院眼科,安徽合肥230022[作者简介]冯先余(1967-),男,硕士研究生,副主任医师(现在安徽
省庐江县人民医院眼科,231500)
[通讯作者]陶黎明,男,研究生导师,教授.
[文章编号]100022200(2009)0120087202・综 述・
人工晶体因素对后囊混浊的影响研究进展
冯先余 综述,陶黎明 审校
[关键词]晶体,人工;白内障摘除术;后囊混浊;综述
[中国图书资料分类法分类号]R 318.18;R 779.66 [文献标识码]A
后囊混浊(posteri or cap sule opacificati on,PCO )是白内障术后远期视力下降的主要原因。PC O 的影响因素较多且复杂。临床资料已证明,人工晶体(intraocular lens,I O L )不仅可以矫正视力,与白内障囊外摘除术相比还可以使术后PCO 发生率降低[1],可见I O L 与PCO 之间有一定的关系。有研究表明,人工晶体的诸多因素对PCO 的发生有较大影响。本文就人工晶体因素对后囊膜混浊的影响作一综述。1 人工晶体材料与PC O 不少研究者对I O L 植入术后患者后囊混浊情况的分析表明,植入软性丙烯酸酯(Acrys of )I O L 者后囊混浊发生的比例比聚甲基丙烯酸甲酯(P MMA )和硅凝胶(Silicone )者明显减少[2],而P MMA 和Silicone 之间并无统计学意义[3,4]。但同样是丙烯酸酯I O L,植入亲水性I O L 术后发生对视力有影
响的PCO 比率比植入疏水性I O L 高[5]。Georgopoul os 等[6]
比较了Silicon 和水凝胶(Hydr ogel )两种材料I O L 时发现术
后前6个月,Silicone 组前囊连续环形撕囊(ACCC )开口范围减小比Hydr ogel 组更明显。Silicone 组前囊截囊口收缩还伴有随后囊截囊口的扩大。Silicone 材料I O L 引起囊膜的主要变化为纤维化,而Hydr ogel I O L 主要引起I O L 表面的晶体上
皮细胞(LECs )增生。但N ishi 等[7]
研究了I O L 种类及光学部分形状与后发性白内障的关系时发现I O L 材料对于PC O 的发展并不重要。
Hollick 等
[4]
将90只眼随机植入P MMA 、Silicone 和
Acrys of 材料的I O L,所有I O L 都是相同大小的光学部及襻,
连续环形撕囊,术后6个月和1、2、3年复查。结果表明,3年后3种材料I O L 后囊膜混浊的百分数差异有统计学意义。Acrys of 后囊膜混浊(10%)比P MMA (56%)和Silicone (33.5%)少。认为使用Acrys of 材料的I O L 与使用P MMA 、
Silicon 材料的I O L 相比能显著降低后囊膜混浊的发生。
程金伟等[8]通过对不同生物材料人工晶体与后囊混浊相互关系的Meta 分析发现,4种常见I O L 材料的后囊混浊发生率由低至高依次为聚丙烯酸、硅凝胶、P MMA 、水凝胶。认