默克 MAS-100 CG 压缩空气 浮游菌采样器 说明书
合集下载
相关主题
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Table of statistical corrections to Feller for SH 300 x 0.6mm Firmware Flow Diagram MAS-100 CG Ex „Manual Mode 1” Firmware Flow Diagram MAS-100 CG Ex „Template-Mode 2” Firmware Flow Diagram MAS-100 CG Ex „Selectable Mode 3 Firmware Flow Diagram MAS-100 CG Ex „Parameter Mode 4” Continue: Firmware Flow Diagram MAS-100 CG Ex „Parameter Mode 4” Firmware Flow Diagram MAS-100 CG Ex „Initial activation of the calibration reminder” EC-Declaration of Conformity ATEX-Certificate
23
23 23 23 24
12
12.1 12.2
Software for MAS-100 CG Ex
Validated software for MAS-100 CG Ex Data communication software
25
25 25
13 14
14.1 14.2 14.3 14.4
Interpreting results Charging the MAS-100 CG Ex
9
9 9 10 10 11 11 11 11 11 11 11
6
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
Perform air sampling in „Manual Mode 1”
Prepare instrument Working in explosion hazardous zones Prepare the instrument for sampling “Manual sampling” with the MAS-100 CG Ex After the sampling process Switch off the MAS-100 CG Ex Interrupt a measurement Low gas flow
5
5 5 5 5 5 5 5
2 3
3.1 3.2
Introduction Basic principle
Gas flow 100 or 50 litres/min Automatic decompression cycle
6 6
7 7
4
4.1
Most important advantages of the MAS-100 CG Ex
1.2
Operating the MAS-100 CG Ex
Read all instruction carefully before operating the instrument. The MAS-100 CG Ex must be operated by specialized laboratory people only.
21
21 21 22 22 23 23
11
11.1 11.2 11.3 11.4
Special applications
Using gas which is not on standard sampler Low gas flow Using microbiological filter at the instrument exit Directions for use in explosion risk areas
®
MBV AG Microbiology and Bioanalytic Industriestrasse 9 CH-8712 Stäfa
Tel. +41 44 928 30 80 Fax +41 44 928 30 89 Mail: info@mbv.ch www.mbv.ch
page 1 of 41 MAS-100 CG Ex_UM_HW_V17_e.docx
12
12 12 12 13 14 14 14 14
7
7.1 7.2 7.3
Perform air sampling in „Template Mode 2”
Prepare instrument Working in explosion hazardous zones “Template mode” sampling with the MAS-100 CG Ex
Battery charging Battery status display Battery replacement Vacuum test for MAS-100 CG Ex unit
25 26
26 26 26 26
15
15.1
Calibration
Calibration reminder
27
new: with individual activation of calibration reminder new: also for oxygen
(FW V3.79)
MAS-100 Systems: The leading microbiological air monitoring systems
approved by: LF page 2 of 41
9.7 9.8 9.9 9.10 9.11 9.12 9.13 9.14 9.15 9.16 9.17
Selecting date format (EU or US) and changing time and date Change volumes Delay menu (Change / Activate / Deactivate ) Select operation mode Manual mode Selectable mode Template mode Select pressure release Print setup parameters User menu Select flow 50% or 100%
15
15 15 16
8 9
9.1 9.2 9.3 9.3.1 9.3.2 9.3.3 9.3.4 9.4 9.5 9.6
Perform air sampling in „Selectable Mode 3” Instrument settings Mode 4
General description Clear protocol data Connecting a printer Basic Information General Printer Settings Printer Citizen CT-S281 Other Printers Print protocol Back to main menu Set time and date
18 19 19 19 19 19 20 20 20 20 21
10
10.1 10.2 10.3 10.4 10.5 10.6
Sampling head
Components of sampling head Opening or closing the sampling head Adjustment of Petri dish Adjusting CONTACT plates Sterilization of sampling head Sampling head
MAS-100 CG Ex User Manual Hardware
MAS-100 CG Ex Professional Microbiological Air Monitoring System for the microbial testing of compressed gases
MAS-100 CG Ex is a registered trademark (MBV AG / Switzerland)
approved by: LF page 3 of 41
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
approved by: LF page 4 of 41
1
Warning notices
1.1
Important Safeguards
The Microbiological Air Sampler Type MAS-100 CG Ex may be opened or charged only outside the explosion hazard zone.
29 29 30 30 30
31 32 33 34 35 36 37 38 39
22
Revision History
41
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
1.3
Charging the MAS-100 CG E来自百度文库
The Microbiological Air Sampler Type MAS-100 CG Ex may be opened or charged only outside the explosion hazard zone.
1.4 Directions for use in explosion risk areas and Environmental Conditions
Index
1
1.1 1.2 1.3 1.4 1.5 1.6 1.7
Warning notices
Important Safeguards Operating the MAS-100 CG Ex Charging the MAS-100 CG Ex Directions for use in explosion risk areas and Environmental Conditions Warranty Malfunction of instrument Working with compressed gas in general
16 17
17 17 17 17 17 18 18 18 18 18
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
Transport trolley
8
8
5
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11
General functions
Overview Initial start-up of the MAS-100 CG Ex = Activation of calibration reminder Switch ON and OFF the MAS-100 CG Ex Calibration reminder Manual or Template mode Last gas / volume used Change gas type Select other volumes Delay function User menu Sampling
27
16
16.1
Technical specifications
Environmental conditions
28
29
17 18 19 20 21
21.1 21.2 21.3 21.4 21.5 21.6 21.7 21.8 21.9
Components check list Care and maintenance Warranty Accessories Appendix
23
23 23 23 24
12
12.1 12.2
Software for MAS-100 CG Ex
Validated software for MAS-100 CG Ex Data communication software
25
25 25
13 14
14.1 14.2 14.3 14.4
Interpreting results Charging the MAS-100 CG Ex
9
9 9 10 10 11 11 11 11 11 11 11
6
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
Perform air sampling in „Manual Mode 1”
Prepare instrument Working in explosion hazardous zones Prepare the instrument for sampling “Manual sampling” with the MAS-100 CG Ex After the sampling process Switch off the MAS-100 CG Ex Interrupt a measurement Low gas flow
5
5 5 5 5 5 5 5
2 3
3.1 3.2
Introduction Basic principle
Gas flow 100 or 50 litres/min Automatic decompression cycle
6 6
7 7
4
4.1
Most important advantages of the MAS-100 CG Ex
1.2
Operating the MAS-100 CG Ex
Read all instruction carefully before operating the instrument. The MAS-100 CG Ex must be operated by specialized laboratory people only.
21
21 21 22 22 23 23
11
11.1 11.2 11.3 11.4
Special applications
Using gas which is not on standard sampler Low gas flow Using microbiological filter at the instrument exit Directions for use in explosion risk areas
®
MBV AG Microbiology and Bioanalytic Industriestrasse 9 CH-8712 Stäfa
Tel. +41 44 928 30 80 Fax +41 44 928 30 89 Mail: info@mbv.ch www.mbv.ch
page 1 of 41 MAS-100 CG Ex_UM_HW_V17_e.docx
12
12 12 12 13 14 14 14 14
7
7.1 7.2 7.3
Perform air sampling in „Template Mode 2”
Prepare instrument Working in explosion hazardous zones “Template mode” sampling with the MAS-100 CG Ex
Battery charging Battery status display Battery replacement Vacuum test for MAS-100 CG Ex unit
25 26
26 26 26 26
15
15.1
Calibration
Calibration reminder
27
new: with individual activation of calibration reminder new: also for oxygen
(FW V3.79)
MAS-100 Systems: The leading microbiological air monitoring systems
approved by: LF page 2 of 41
9.7 9.8 9.9 9.10 9.11 9.12 9.13 9.14 9.15 9.16 9.17
Selecting date format (EU or US) and changing time and date Change volumes Delay menu (Change / Activate / Deactivate ) Select operation mode Manual mode Selectable mode Template mode Select pressure release Print setup parameters User menu Select flow 50% or 100%
15
15 15 16
8 9
9.1 9.2 9.3 9.3.1 9.3.2 9.3.3 9.3.4 9.4 9.5 9.6
Perform air sampling in „Selectable Mode 3” Instrument settings Mode 4
General description Clear protocol data Connecting a printer Basic Information General Printer Settings Printer Citizen CT-S281 Other Printers Print protocol Back to main menu Set time and date
18 19 19 19 19 19 20 20 20 20 21
10
10.1 10.2 10.3 10.4 10.5 10.6
Sampling head
Components of sampling head Opening or closing the sampling head Adjustment of Petri dish Adjusting CONTACT plates Sterilization of sampling head Sampling head
MAS-100 CG Ex User Manual Hardware
MAS-100 CG Ex Professional Microbiological Air Monitoring System for the microbial testing of compressed gases
MAS-100 CG Ex is a registered trademark (MBV AG / Switzerland)
approved by: LF page 3 of 41
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
approved by: LF page 4 of 41
1
Warning notices
1.1
Important Safeguards
The Microbiological Air Sampler Type MAS-100 CG Ex may be opened or charged only outside the explosion hazard zone.
29 29 30 30 30
31 32 33 34 35 36 37 38 39
22
Revision History
41
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
1.3
Charging the MAS-100 CG E来自百度文库
The Microbiological Air Sampler Type MAS-100 CG Ex may be opened or charged only outside the explosion hazard zone.
1.4 Directions for use in explosion risk areas and Environmental Conditions
Index
1
1.1 1.2 1.3 1.4 1.5 1.6 1.7
Warning notices
Important Safeguards Operating the MAS-100 CG Ex Charging the MAS-100 CG Ex Directions for use in explosion risk areas and Environmental Conditions Warranty Malfunction of instrument Working with compressed gas in general
16 17
17 17 17 17 17 18 18 18 18 18
MAS-100 CG Ex User Manual Hardware MAS-100 CG Ex_UM_HW_V17_e.docx
valid from: 2014.01.08 version template/document: 2.0 / NA
Transport trolley
8
8
5
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11
General functions
Overview Initial start-up of the MAS-100 CG Ex = Activation of calibration reminder Switch ON and OFF the MAS-100 CG Ex Calibration reminder Manual or Template mode Last gas / volume used Change gas type Select other volumes Delay function User menu Sampling
27
16
16.1
Technical specifications
Environmental conditions
28
29
17 18 19 20 21
21.1 21.2 21.3 21.4 21.5 21.6 21.7 21.8 21.9
Components check list Care and maintenance Warranty Accessories Appendix