溶液法测定极性分子的偶极矩(上课用)
溶液法测定极性分子的偶极矩-1
溶液法测定极性分子的偶极矩摘要:为了解电介质极化与分子极化的概念,掌握溶液法测定极性分子永久偶极矩的理论模型和实验技术。
通过配制不同浓度的乙酸乙酯的极稀溶液,测定它们的介电常数和折光率以及溶液密度,得到a、b、c。
实验测得a=1.3489,b=0.0859,c=-0.0464再通过克劳修斯-莫索提-德拜方程求得P m=81.1516, P E=22.7002,最后得到乙酸乙酯的偶极矩为μ=5.93*e-30C*m,与文献值的相对误差为7.54%。
由此可看出溶液法测定极性分子的偶极矩是一项非常简单易操作的实验方法。
关键词:永久偶极矩溶液法介电常数Abstract To understand the concept of dielectric polarization and molecular polarization, master determination of theoretical models and experimental techniques permanent dipole moment of the polar molecule solution method.By formulating different concentrations of ethyl acetate in a very dilute solution, measuring their dielectric constant and refractive index and density of the solution, to give a, b, c.Experimentally measured a = 1.3489, b = 0.0859, c=-0.0464Through Clausius - Mosuo Ti - Debye equation obtained Pm= 81.1516, P E= 22.7002,Finally get the dipole moment of ethyl acetate μ = 5.93 * e-30C *m,Literature values and the relative error is 7.54%.Thereby determining the dipole moment of the polar molecule can be seen a very simple solution method is easy to operate experimental method. Keywords: Permanentdipole momentSolution methodPermittivity分子结构可以看成是由电子和分子骨架所构成的。
溶液法测定极性分子的偶极矩
二 实验原理
在可见光 下测定溶 液的R2∞
本实验
乙酸乙酯-四氯 化碳溶液
无限稀释溶 液的介电常 数和溶液的 密度求P2∞
然后由(10)式计算乙酸乙酯的偶极矩。
二 实验原理
2.极化度的测定
无限稀时,溶质的摩尔极化度P2∞的公式为
2
3αε1 M1 ε1 1 M 2 βM1 P P lim P2 2 x2 0 ρ1 ε1 2 ρ1 ε1 2
阿贝折光仪
比重管
电吹风
四、实验步骤
1. 折射率的测定
用阿贝折光仪测定四氯化碳及各配制溶液的折 光率,注意测定时各样品需加样3次,每次读取 三个数据。
2. 介电常数的测定
(1) 将电容测量仪通电,预热10min。
四、实验步骤
(2)将电容仪与电容池,调节零电位器使数字表 头指示为零。然后测定C′空值。 (3)移取1mL四氯化碳加入到电容池中,数字表头 上所示值即为C′标
溶液法测定极性分 子的偶极矩
—— Dipole Moment of a Polar Molecule
化学系基础实验中心
目的要求 实验原理
实验步骤 注意事项
实验成败的关键
实验讨论
实验仪器
数据处理
思考题
一 目的要求
了解偶极矩与分子电性质的关系 掌握溶液法测定偶极矩的实验技术 用溶液法测定乙酸乙酯的偶极矩
当交变电场的频率进一步增加到大于1015s-1的高频(可 见光和紫外频率 ) 时,极性分子的摩尔极化度等于电 子极化度P电子。
二 实验原理
原则上只要在低频电场下测得极性分子的摩尔极化度 P,在红外频率下测得极性分子的摩尔诱导极化度 P诱
物理化学-实验三十八:溶液法测定极性分子的偶极矩
实验三十八 溶液法测定极性分子的偶极矩一、实验目的1.测定氯仿在环已烷中的偶极矩,了解偶极矩与分子电性的关系。
2.了解Clansius-Mosotti-Debye 方程的意义及公式的使用范围。
3.掌握密度管的使用与电容的测定。
二、实验原理分子可近似看成由电子云和分子骨架(包括原子核和内层电子)组成。
非极性分子的正、负电荷中心是重合的,而极性分子的正、负电荷中心是分离的,其分离程度的大小与分子极性大小有关,可用“偶极矩”这一物理量来描述。
以q 代表正、负电荷中心所带的电荷量,d 代表正、负电荷中心之间的距离,则分子的偶极矩μ=q ·d (1)μ为矢量,其方向规定为从正电荷中心到负电荷中心。
极性分子具有的偶极矩又称永久偶极矩,在没有外电场时,由于分子的热运动,偶极矩指向各个方向的机会相同,故偶极矩的统计值为零。
但当有外电场存在时,偶极矩会在外电场的作用下沿电场方向定向排列,此时我们称分子被极化了,极化的程度可用分子的摩尔取向极化度取向P 来衡量。
除摩尔取向极化度取向P 外,在外电场作用下,极性分子和非极性分子都会发生电子云对分子骨架的相对移动和分子骨架的变形,这种现象称为变形极化,可用摩尔变形极化度变形P 来衡量。
显然,变形P 由电子极化度电子P 和原子极化度原子P 组成。
所以,对极性分子而言,分子的摩尔极化度P 由三部分组成,即P =取向P +电子P +原子P (2)当处在交变电场中,根据交变电场的频率不同,极性分子的摩尔极化度P 可有以下三种不同情况:(1)低频下(<1010秒―1)或静电场中,P =取向P +电子P +原子P ;(2)中频下(1012秒―1~1014秒―1)(即红外频率下),由于极性分子来不及沿电场取向,故取向P =0,此时P =变形P =电子P +原子P ;(3)高频下(>1015秒―1)(即紫外频率和可见光频率下),极性分子的取向运动和分子骨架变形都跟不上电场的变化,此时取向P =0,原子P =0,P =电子P 。
溶液法测定偶极矩结构化学实验二
结构化学实验二溶液法测定极性分子的偶极矩一、实验目的1.用溶液法测定正丁醇的偶极矩2.了解偶极矩与分子电性质的关系3. 掌握溶液法测定偶极矩的实验技术二、实验原理1.偶极矩与极化度两个大小相等方向相反的电荷体系的偶极矩定义为:μ=q d (1)极性分子在电场作用下极化程度可用摩尔定向极化度P定向来衡量:P定向=4/3πN A*μ02/(3kT)=4/9πN A*μ02/(kT) (2)极性分子所产生的摩尔极化度P是摩尔定向极化度、摩尔电子诱导极化度和摩尔原子诱导极化度的总和:P=P定向+P诱导=P定向+P电子+P原子(3)2. 溶液法测定偶极矩无限稀释时溶质的摩尔极化度的公式:P=P2∞=3αε1/(ε1+2)2* Μ1/ρ1+ (ε1-1)/(ε1+2) * (Μ2-βΜ1)/ρ1(9) 习惯上用溶质的摩尔折射度R2表示高频区测得的摩尔极化度,因为此时P 定向=0,P原子=0,推导出无限稀释时溶质的摩尔折射度的公式:P电子=R2∞=(n12-1)/(n12+2) * (Μ2-βΜ1)/ρ1+6n12Μ1γ/[(n12+2)2*ρ1] (13) 稀溶液的近似公式:ε溶=ε1(1+α* x2) (7)ρ溶=ρ1(1+β*x2) (8)n溶=n1(1-γ*x2) (12) 由P定向=P2∞-R2∞=4/9πN A*μ02/(kT) (14)得μ0=0.0128*[(P2∞-R2∞)*T]1/2 (D)(15)需测定参数:α,β,γ,ε1,ρ1 n1三、仪器和试剂仪器:阿贝折光仪1台;比重管1只;电容测量仪一台;电容池一台;电子天平一台;电吹风一只;25ml容量瓶4支;25ml、5ml、1ml移液管各一支;滴管5只;5ml针筒一支;针头一支;吸耳球两个试剂:正丁醇(分析纯);环己烷(分析纯);蒸馏水;丙酮四、实验步骤1.溶液的配制配制4种正丁醇的摩尔分数分别是0.05、0.10、0.15、0.20的正丁醇-环己烷溶液。
溶液法测定极性分子的偶极矩实验报告
结构化学实验报告——溶液法测定极性分子的偶极矩一、实验目的1.用溶液法测定正丁醇的偶极矩2.了解偶极矩与分子电性质的关系3.掌握溶液法测定偶极矩的实验技术2、实验原理1.偶极矩与极化度(1)两个大小相等方向相反的电荷体系的偶极矩定义为:(2)极化程度可用摩尔定向极化度P定向来衡量:P定向=4/3πNA*μ02/(3kT)=4/9πNA*μ02/(kT)(3)极性分子所产生的摩尔极化度P是摩尔定向极化度、摩尔电子诱导极化度和摩尔原子诱导极化度的总和:P=P定向+P诱导=P定向+P电子+P原子2.偶极矩的测定方法(溶液法测定偶极矩)(1)无限稀释时溶质的摩尔极化度的公式:P=P2∞=3αε1/(ε1+2)2 * Μ1/ρ1 + (ε1-1)/(ε1+2) * (Μ2-βΜ1)/ρ1(2)习惯上用溶质的摩尔折射度R2表示高频区测得的摩尔极化度,因为此时P定向=0,P原子=0,推导出无限稀释时溶质的摩尔折射度的公式:P电子=R2∞=n2-1/(n12+2) * (Μ2-βΜ1)/ρ1+6n12Μ1γ/[(n12+2)2*ρ1](3) 近似公式:ε溶=ε1(1+α* x2)ρ溶=ρ1(1+β*x2)n溶=n1(1-γ*x2)(4) 永久偶极矩的获得考虑到摩尔原子诱导极化度通常只有摩尔电子极化度的5%-15%,而且P定向又比P原子大得多,故常常忽略P原子,可得P定向=P2∞-R2∞=4/9πNA*μ02/(kT)μ0=0.0128*[(P2∞-R2∞)*T]1/2(5)介电常数的测定:用空气与一已知介电常数ε溶的标准物质分别测得电容C/空,C/标C/空=C空+Cd=C0+Cd C/标=C标+Cd则通过上两式可求得C0=(C/标-C/空)/(ε标-1) Cd=C/空-C0=C/空-(C/标-C/空)/(ε标-1)ε溶= C溶/ C0=(C/溶- Cd)/ C03、仪器和试剂仪器:阿贝折光仪1台;比重管1只;电容测量仪一台;电容池一台;电子天平一台;电吹风一只;25ml容量瓶4支;25ml、5ml、1ml移液管各一支;滴管5只;5ml针筒一支;针头一支;吸耳球一个;试剂:正丁醇(分析纯);环己烷(分析纯);蒸馏水;丙酮4、实验步骤1.溶液的配制配制4种正丁醇的摩尔分数分别是0.05、0.10、0.15、0.20的正丁醇-环己烷溶液。
溶液法测定极性分子的偶极矩
溶液法测定极性分子的偶极矩一、实验目的1、了解偶极矩与分子电性质的关系2、掌握溶液法测定偶极矩的实验技术3、用溶液法测定乙酸乙酯的偶极矩二、实验原理1、分子结构可以近似地被石成是由电子。
和对于骨架(原子核及内层电子)所构成的。
由于分子空间构型的不同,其正、负电荷中心可能是重合的,也可能不重合,前者称为非极性分子,后者称为极性分子。
偶极矩μ是用来度量分子极性的大小的,其定义是μ=q·d通过偶极矩的测定可以了解分子结构中有关电子云的分布和分子的对称性等情况,还可以用来判别几何异构体和分子的立体结构等。
2、把物质分子的微观性质偶极矩和它的宏观性质介电常数、密度和折射率联系起来,分子的永久偶极矩就可用下面简化式计算μ=0.04274×10-30(P2∞-R2∞)T上述测求极性分子偶极矩的方法称为溶液法。
溶液法测得的溶质偶极矩与气相测得的真实值间存在偏差,造成这种现象的原因是非极性溶剂与极性溶质分子相互间的作用—“溶剂化”作用,这种偏差现象称为溶液法测量偶极矩的“溶剂效应”。
3、介电常数是通过测量电容计算而得到的。
电容池两极间真空时和充满某物质时电容分别为C0和C x,则某物质的介电常数ε与电容的关系为ε=εx/ε0=C x/ C0当将电容池插在小电容测量仪上测量电容时,实际测量所得的电容应是电容池两极间的电容和整个测试系统中的分布电容C d并联构成。
C d是一个恒定值,称为仪器的本底值,在测量时应予扣除,否则会引进误差,因此必须先求出本底值C d,并在以后的各次测量中予以扣除。
C标‘=C标+C dC‘x=C x+C d三、实验仪器与试剂仪器:阿贝折射仪、电吹风、介电常数测量仪、容量瓶(10ml)、电容池试剂:乙酸乙酯(分析纯)、四氯化碳四、实验内容1、取编号为1~5的10 ml容量瓶用电子天平分别称量其重量m1。
2、溶液配置用移液管分别移取10ml不同浓度的乙酸乙酯一四氯化碳溶液(50ml含1ml、3ml、5ml、7ml、9ml乙酸乙酯)放入已编好号的5个容量瓶中,并分别称量其重量m2。
大学物理化学实验报告-溶液法测定极性分子的偶极距
物理化学实验报告院系化学化工学院班级化学061学号13姓名沈建明实验名称 溶液法测定极性分子的偶极距 日期 2009.3.26 同组者姓名 史黄亮 室温 17.86℃ 气压 101.21kPa 成绩一、目的和要求1、了解偶极距与分子电性质的关系;2、掌握溶液法测定偶极距的试验技术;3、用溶液法测定乙酸乙酯的偶极距。
二、基本原理 1. 偶极矩和极化度分子的极性可以用“偶极矩”来度量。
其定义为(1)q 为正、负电荷中心所带电荷量,d 为正、负电荷中心距离。
是向量,其方向规定从正到负。
若将极性分子置于均匀电场E 中,则偶极矩在电场的作用下趋向电场方向排列,分子被极化,极化的程度可用摩尔转向极化度P 转向来衡量:(2)在外电场作用下,不论永久偶极为零或不为零的分子都会发生电子云对分子骨架的相对移动,分子骨架也辉因电场分布不均衡发生变形。
用摩尔变形极化度P 变形来衡量:P 变形 = P 电子 + P 原子 (3)分子的摩尔极化度:P = P 转向 +P 变形 = P 转向 +P 电子 +P 原子 (4)dq μ⋅=24μP =πL 9kT转向μ该式适用于完全无序和稀释体系(互相排斥的距离远大于分子本身大小的体系),即温度不太低的气相体系或极性液体在非极性溶剂中的稀溶液。
在中频场中转向P = 0。
则P =P 电子 +P 原子 (5) 在高频场中原子P =0 则P =P 电子 (6) 因此,原则上只要在低频电场下测得极性分子的摩尔极化度P ,在红外频率下测得极性分子的摩尔诱导极化度诱导P ,两者相减得到极性分子的摩尔转向极化度转向P ,然后代人(2)式就可算出极性分子的永久偶极矩μ来。
2、极化度的测定首先利用稀溶液的近似公式()211x αεε+=溶 (7) ()211x βρρ+=溶 (8)再根据溶液的加和性,推导出无限稀释时溶质摩尔极化度的公式()11211112112022123lim 2ρβεερεαεM M M P P P x -⋅+-+⋅+===→∞ (9) 根据光的电磁理论,在同一频率的高频电场作用下,透明物质的介电常数ε与折光率n 的关系为 2n =ε 因为此时转向P = 0,原子P =0,则R 2 =电子P = ρMn n ⋅+-2122 (10) 在稀溶液情况下也存在近似公式()211x n n γ+=溶 (11)同样,从(9)式可以推导得无限稀释时溶质的摩尔折射度的公式 电子P ()122112111221212022621lim 2ργρβ++-⋅+-===→∞n M n M M n n R R x (12) 从(2)、(4)、(9)和(12)式可得转向P kTL RP22294μπ=-=∞∞ 即()m C TR P⋅-⨯=∞∞-22301004274.0μ3、介电常数的测定介电常数是通过测定电容计算而得。
童海港《溶液法测定极性分子的偶极矩》
童海港《溶液法测定极性分子的偶极矩》
本文介绍了溶液法测定极性分子的偶极矩的实验方法及实验原理。
首先,作者介绍了偶极矩的概念和意义,偶极矩是描述极性分子内部存在的极性程度的物理量,它可以描述分子中带电性的分布情况和分子中正负电荷的分离程度。
接着,作者介绍了偶极矩测定的方法,即溶液法。
溶液法是通过分析分子在溶液中的电性质来确定分子的偶极矩。
在实验中,首先需要选取适当的溶剂,使得被测物质在溶剂中可以较好地溶解,且分子量较小,具有较高的极性。
然后,通过测量被测物质与溶质溶液的电导率变化,来确定被测物质的偶极矩大小。
偶极矩的测定公式为:μ = (dkT/(3πηD))1/2其中,μ为偶极矩大小,d 为被测物质的平均距离,kT为玻尔兹曼常数乘以温度,η为溶剂的黏度,D为被测物质的扩散系数。
最后,作者还介绍了实验中需要注意的问题和应该注意的实验技巧,以保证实验的准确性和可靠性。
整篇文章语言简洁清晰,讲述了测定极性分子偶极矩的方法和原理,对于科研人员和学生进行实验时都有很大参考价值。
溶液法测定极性分子的偶极矩试验目的了解电介质极化与分子极
溶液法测定极性分子的偶极矩一、实验目的了解电介质极化与分子极化的概念,以及偶极矩与分子极化性质的关系。
掌握溶液法测定极性分子永久偶极矩的理论模型和实验技术,用溶液法测定乙酸乙酯的偶极矩。
二、实验原理德拜(Peter Joseph William Debye)指出,所谓极性物质的分子尽管是电中性的,但仍然拥有未曾消失的电偶极矩,即使在没有外加电磁场时也是如此。
分子偶极矩的大小可以从介电常数的数据中获得,而对分子偶极矩的测量和研究一直是表征分子特性重要步骤。
1、偶极矩、极化强度、电极化率和相对电容率(相对介电常数)首先定义一个电介质的偶极矩(dipole moment)。
考虑一簇聚集在一起的电荷,总的净电荷为零,这样一堆电荷的偶极矩是一个矢量,其各个分量可以定义为式中电荷的坐标为。
偶极矩的SI制单位是:。
将物质置于电场之中通常会产生两种效应:导电和极化。
导电是在一个相对较长的(与分子尺度相比)距离上输运带电粒子。
极化是指在一个相对较短的(小于等于分子直径)距离上使电荷发生相对位移,这些电荷被束缚在一个基本稳定的、非刚性的带电粒子集合体中(比如一个中性的分子)。
一个物质的极化状态可以用矢量表示,称为极化强度(polarization)。
矢量的大小定义为电介质内的电偶极矩密度,也就是单位体积的平均电偶极矩,又称为电极化密度,或电极化矢量。
这定义所指的电偶极矩包括永久电偶极矩和感应电偶极矩。
的国际单位制度量单位是。
为取平均的单位体积当然很小,但一定包含有足够多的分子。
在一个微小的区域内,的值依赖于该区域内的电场强度。
在这里,有必要澄清一下物质内部的电场强度的概念。
在真空中任意一点的电场强度的定义为:在该点放置一个电荷为的无限微小的“试验电荷”,则该“试验电荷”所受到的力为。
当将这个定义应用到物质内部时,在原子尺度上会引起巨大的电场涨落。
为此,物质内部某一点的宏观电场强度定义为在该点邻近的小区域内原子尺度电场强度的平均值,这个小区域当然比通常标准要小得多,但仍足以容纳足够多的分子。
溶液法测定极性分子偶极矩的数据处理方法
溶液法测定极性分子偶极矩的数据处理方法极性分子偶极矩是为了 Understanding the Molecular Structure and Physical Properties 诸如 Intermolecular Interactions, Biological Activity, 而确定极性分子的重要结构特征之一。
溶液法测定极性分子偶极矩的数据处理方法可以帮助人们对极性分子偶极矩有更深入的了解。
在溶液法测定极性分子偶极矩的数据处理方法中,首先需要满足三种条件:(1)电偶极矩应被定义为极性分子在不同位置的解析函数;(2)极性分子偶极矩应被建模为等长曲线;(3)偶极矩的变化必须被解释为两个或多个基础偶极矩之和。
当满足以上三个条件之后,需要采用团簇方法将极性分子偶极矩的数据分组处理。
这种方法能够根据极性分子的类群结构和物理特性将大量的极性分子偶极矩数据分组处理,例如氢键、疏水性、电荷密度、活性基团等。
团簇分析方法需要使用体系模拟数据,包括许多用于测量极性分子偶极矩的参数,例如键长、夹角、双键邻域、共轭位置、电荷密度、极化力、氢键能等测定参数。
而使用体系模拟数据,则需要使用数据拟合法,来根据上述各个参数的值,估算出极性分子的偶极矩和变化规律。
最后,通过对比两个数据集,即实测数据和模拟数据,可以使用计算机辅助的数据分析工具,如MATLAB,比较分析两个数据集,以确定极性分子偶极矩的趋势和变化规律。
总之,为了更准确地测定极性分子偶极矩,溶液法测定极性分子偶极矩的数据处理方法是非常有用的,其具体过程如前所述,旨在通过团簇法将大量的极性分子偶极矩数据分组处理,并利用数据拟合法和计算机辅助的数据分析工具,以便更准确地测量极性分子偶极矩,以更好地理解极性分子的结构和物理特性。
实验十五 溶液法测定极性分子的偶极矩
1.偶极矩与极化度
分子由带正电荷的原子核和带负电荷的电子组成。由于正、负电荷总数相等, 整个分子是电中性的。然而,由于电子云在空间分布的不同,即分子空间构型的 不同,正、负电荷中心可能重合,也可能不重合。前者为非极性分子,后者称为 极性分子。分子极性大小用偶极矩 μ 来度量,其定义为
μ = q⋅d
式中,q 为正、负电荷中心所带的电荷量; d 是正、负电荷中心间的距离。偶极矩 的 SI 单位是库﹒米 (C·m)。
P诱导 = P电子 + P原子
式中, P电子 是电子极化度、 P原子 是原子极化度。
若外电场是交变电场时,极性分子的排列方向即分子偶极矩的方向将随电场方向 而转向,偶极矩转向所需的时间称为松弛时间。极性分子转向极化的松弛时间为 10-11-10-12S ,原子极化的松弛时间约为 10-14S ,电子极化的松弛时间为小于 10-15S。
由于整个测试系统存在分布电容,所以实测的电容 C′是样品电容 C 和分布 电容 Cd 之和,即
C样' = C + Cd
显然,为了求 C 首先就要确定 Cd(对同一台仪器为一恒定值)值,方法是—先 测定无样品时空气的电空 C空' ,则有
C空' = C空 + Cd
再通过一已知介电常数( ε标 )的标准物质的电容的 C标' 测定
溶液法测定极性分子的偶极矩(上课用)
溶液法测定极性分子的偶极矩I. 目的与要求一、 用溶液法测定乙酸乙酯的偶极矩二、 了解偶极矩与分子电性质的关系三、 掌握溶液法测定偶极矩的实验技术I I. 基本原理一、偶极矩与极化度分子结构可以近似地被石成是由电子。
和对于骨架〔原子核与内层电子〕所构成的。
由于分子空间构型的不同,其正、负电荷中心可能是重合的,也可能不重合,前者称为非极性分子,后者称为极性分子。
图1 电偶极矩示意图1912年,德拜〔Debye 〕提出“偶极矩〞μ的概念来度量分子极性的大小,如图1所示,其定义是 d q ⋅=μ 〔1〕式中 q 是正、负电荷中心所带的电荷量,d 为正、负电荷中心之间的距离,μ是一个向量,其方向规定从正到负。
因分子中原子间距离的数量级为1010-m ,电荷的数量级为2010-C ,所以偶极矩的数量级是3010-C·m 。
通过偶极矩的测定可以了解分子结构中有关电子云的分布和分子的对称性等情况,还可以用来判别几何异构体和分子的立体结构等。
极性分子具有永久偶极矩,但由于分子的热运动,偶极矩指向各个方向的机会相同,所以偶极矩的统计值等于零。
若将极性分子置于均匀的电场中,则偶极矩在电场的作用下会趋向电场方向排列。
这时我们称这些分子被极化了,极化的程度可用摩尔转向极化度转向P 来衡量。
转向P 与永久偶极矩平方成正比,与热力学温度T 成反比kTL kT L P 2294334μπμπ=⋅=转向 〔2〕 式中k 为玻耳兹曼常数,L 为阿伏加德罗常数。
在外电场作用下,不论极性分子或非极性分子都会发生电子云对分子骨架的相对移动,分子骨架也会发生变形,这种现象称为诱导极化或变形极化,用摩尔诱导极化度诱导P 来衡量。
显然,诱导P 可分为二项,即电子极化度电子P ,和原子极化度原子P ,因此诱导P = 电子P + 原子P 。
诱导P 与外电场强度成正比,与温度无关。
如果外电场是交变电场,极性分子的极化情况则与交变电场的频率有关。
溶液法测分子偶极距
溶液法测定极性分子的偶极矩Ⅰ、实验目的:(1) 了解偶极矩与分子电性质的关系; (2) 掌握溶液法测定偶极矩的实验技术; (3) 用溶液法测定乙酸乙酯的偶极矩;Ⅱ、实验目的:偶极矩(μ)的概念来度量分子极性的大小:μ=q ·d 。
P 转向与永久偶极矩平方成正比,与热力学温度T 成反比。
在外电场的作用下产生的诱导极化:P 诱导=P 电子+P 原子。
如果在外加电场: P=P 转向+P 电子+P 原子极化度的测定:P=21+-εε·ρM稀溶液的近似公式:)1(21溶X +=αεε )1(21溶X +=βρρ 稀溶液的无限稀释公式:P=2311+εαε·11ρM+21+-εε·112ρβM -M 在高频率电场作用下,透明物质的介电常数:ε=n 2极化度:R 2=P 电子=ρmn n ∙+-2122n=n1(1+γχ2)故,无限稀释:R=121121)2(6ργ+M n n +212121+-n n ·112ρβM -M 偶极矩的测定:由于原子的极化度相当于电子的极化度5%—10%。
μ/(C ·m )=0.04274×10-30T R P )(22∞∞- (C ·m )T 为开氏温度T )R -P (128.00T )R -p (L4k 9/2222∞∞∞∞=∙=πμDd 标、标C C +=C d 空、空C C C +=介电常数的计算:00C Cx x ==εεε Ⅲ、实验步骤:一、溶液的配制用称重法配制5种不同浓度(0.01979、0.05939、0.09903、0.1387、0.1784 g/cm 3) 的乙酸乙酯-四氯化碳溶液,分别盛于容量瓶中,控制乙酸乙酯的浓度在0.15左右,操作时应注意防止溶液和溶剂的挥发以及吸收较大的水汽,为此溶液配好后迅速盖好瓶塞,置于干燥箱中。
二折光率的测定在(25±0.1)℃条件下用阿贝折射仪测定四氯化碳及各组中所配溶液的折光率。
溶液法测定偶极矩
(3)由样品折光率计算样品质量组成 将测得的折光率求平均后平方,带入之前做出的标准曲线,即可得到样品的质量分数
J1 J2 n1 1.4534 1.4563 n2 1.4534 1.4562 n3 1.4534 1.4563 n4 1.4533 1.4564 n 1.4534 1.4563 2 ������ 2.112299 2.12081 W 0.035627 0.016192 (4)计算样品介电常数,做������ − ������图 J1 J2 C1′(pF) 8.51 8.01 C2′(pF) 8.51 8.01 C3′(pF) 8.5 8 ������ ′(pF) 8.507 8.007 C(pF) 6.386613 5.886613 ε (图中保 2.531076 2.332922 留四位)
折光率对浓度标准曲线
2.13 2.125 折 光 2.115 率 平 2.11 方 2 2.105 n 2.12 2.1203 2.1190 2.1146 2.1282 y = -0.437x + 2.127 R² = 0.963
2.1086
2.1 2.095 0 0.01 0.02 0.03 0.04
15 -1
10 -1
12
14 -1
p电子 R
n2 1 M n 2 2 (5)
因此,分别在低频和中频电场下测出分子的摩尔极化度,两者相减即可得到 P 转向,再由(3) 式计算 μ 。 通过测定偶极矩, 可以了解分子中电子云的分布和分子对称性, 判断几何异构体和分子 的立体结构。 所谓溶液法就是将极性待测物溶于非极性溶剂中进行测定, 然后外推到无限稀释。 因为 在无限稀的溶液中, 极性溶质分子所处的状态与它在气相时十分相近, 此时分子的摩尔极化 度就可视为(5)的 P。 在稀溶液当中,溶液的摩尔极化度 P 可用下式求出: (6) P P1 x1 p 2 x 2 (1-溶剂,2-溶质,x-摩尔分数)
溶液法测定极性分子的偶极距
实验报告化学测量与计算实验U实验日期:2017.05. 交报告日期:2017.05.一、实验目的1. 用溶液法测定正丁醇的偶极矩;2. 了解偶极矩与分子电性质的关系;3. 掌握溶液法测定偶极矩的实验技术。
二、实验原理1•偶极矩与摩尔极化度体系的偶极矩定义为:I 二兀圧分子的偶极距可以是分子本身所固有的,也可以是在外电场作用下分子的正负电荷中心发生变化而引起的。
前者成为分子的永久偶极距,记为"1;后者称为分子的诱导偶极距,记为将极性分子至于静电场或低频电场中,外电场使得极性分子克服热运动,其永久偶极矩在电场作用下趋于电场方向排列,呈现为平均偶极矩。
分子极化用摩尔定向极化度来衡量2 24 卩0 斗如P定旷列“丽=卩叽叼P原子、电子极化统称诱导极化,诱导偶极矩用摩尔诱导极化度. 来衡量。
极性分子所产生的摩尔极化度■'是摩尔定向极化度和摩尔诱导极化度的总和,即P =卩定向十P请导=P定向+ P电子十卩原子在高频电场下,极性分子的定向运动跟不上电场的变化,电子仍可以沿电场定向(电子质量很P — n p小,惯性小),此时■。
因此先在高频电场下测得极性分子的摩尔电子诱导极化度,再在低频电场下测得极性分子的摩尔极化度,两者相减就可以得到分子的摩尔定向极化度 "。
(忽略极性分子的摩尔原子极化率" )2. 溶液法测定偶极矩在无限稀释的非极性溶剂的溶液中,溶质分子之间的分子作用力可以忽略不计,所处的状态和气态时相近,其摩尔极化度P2"可以看作是P。
无限稀释时溶质的摩尔极化度的公式为P =吩lim =----------------------- 十---------------2丁0 (£]十2)片5+2 Pi根据光的电磁理论,在同一频率的高频电场作用透明物质的介电常数&与光的折射率n的关系为:& =n可用无限稀释时溶质的摩尔折射度'表示高频区测得的摩尔极化度,因为此时P ■_ = = lim R 卩宣向=6戶原了亠°勺fM L y (nJ + 2/ 时+ 2;?-与溶剂和溶质的摩尔质量、摩尔分数、密度、介电常数、折射率等有关。
溶液法测定极性分子的偶极矩(De...
溶液法测定极性分子的偶极矩(Determination of dipole moment of polar molecule by solution method)Determination of dipole moment of polar molecule by solution methodI. objectives and requirementsDetermination of dipole moment of ethyl acetate by solution methodUnderstand the relationship between dipole moment and molecular electrical propertiesThe experimental technique of measuring dipole moment by solution methodThe basic principles of I I.Dipole moment and polarizabilityThe molecular structure can be approximated by stone and is made up of electrons. And for the skeleton (nuclei and inner electrons). Because of the different configurations of molecular space, the centers of positive and negative charges may coincide or overlap. The former is called nonpolar molecule, and the latter is called polar molecule.Fig. 1 electric dipole moment indicationIn 1912, Debye (Debye) proposed the concept of dipole momentMu to measure the magnitude of molecular polarity, as shown in Figure 1EMBED Equation.3 (1)In the formula, q is the charge of the positive and negative charge centers, D is the distance between the positive and negative charge centers, and Mu is a vector whose direction is from positive to negative. The order of magnitude of the dipole moment is EMBED, Equation.3, C, m, because the magnitude of the distance between atoms is EMBED, Equation.3, m, and the order of charge is EMBED, Equation.3 and C.Through the determination of dipole moment, we can understand the distribution of molecular cloud and symmetry of molecules in molecular structure, and also can be used to distinguish the geometric isomer and the three-dimensional structure of molecules.Polar molecules have permanent dipole moments, but because of the thermal motion of molecules, the dipole moment has the same chance of pointing in all directions, so the dipole moment is equal to zero. If the polar molecule is placed in a uniform electric field, the dipole moment will tend to the electric field in the direction of the electric field. At this point we call these molecules polarized, and the degree of polarization can be measured by the molar polarization EMBED Equation.3.The EMBED Equation.3 is proportional to the square of the permanent dipole moment and inversely proportional to the thermodynamic temperature TEMBED Equation.3 (2)In the formula, K is the Boltzmann constant and L is the A Vogadero constant.In the external electric field, regardless of polar molecules or non polar molecules will occur relatively mobile electronic cloud on the molecular skeleton, the molecular skeleton will deform, this phenomenon is called polarization or polarization induced deformation, to measure the polarization EMBED Equation.3 induced by moore. Obviously, EMBED Equation.3 can be divided into two, namely electronic polarization EMBED Equation.3, EMBED Equation.3 and atomic polarizability, so EMBED Equation.3 = EMBED Equation.3 + EMBED Equation.3. EMBED Equation.3 is directly proportional to the external electric field strength and independent of temperature.If the external electric field is an alternating electric field, the polarization of the polar molecule is related to the frequency of the alternating field. When the frequency is lower than EMBED, Equation.3 and S-1 in the low frequency electric field or electrostatic field, the polarization polarization P produced by polar molecules is the sum of the steering polarization, the electron polarization and the atomic polarizationEMBED, Equation.3 = EMBED, Equation.3 + EMBED, Equation.3 + EMBED, Equation.3 (3)When the frequency is increased to EMBED Equation.3 to EMBEDEquation.3 S-1 (infrared frequency), electric field alternating period is less than the molecular dipole moment of relaxation time, change of steering movement of polar molecules with no electric field, the polar molecules can along the electric field direction, so the EMBED Equation.3 = 0. At this time, the molar polarization of polar molecules is equal to the molar induced polarization degree EMBED Equation.3. When the frequency of alternating electric field further increased to more than EMBED Equation.3 S-1 high frequency (visible light and ultraviolet frequency), change to the movement and deformation of the molecular skeleton could not keep up with the polarity of the electric field of the molecule, the molar polarization of polar molecules is equal to the electronic polarization of EMBED Equation.3.Therefore, in principle, as long as the low frequency electric field measured polar molecules molar polarization in P, infrared frequencies measured Moore polar molecules induced polarization of EMBED Equation.3 Moore, obtained by subtracting the two polar molecules to the degree of polarization of EMBED Equation.3 generation (2), then you can type permanent dipole moment. To calculate the molecular polarity.Two. Determination of polarizabilityClausius mosotti Debye, and (Clausius Mosotti Debye) the relationship between molar polarization P and dielectric constant from electromagnetic theoryEMBED Equation.3 (4)In the formula, M is the molar mass of the analyte, P is the density of the material, e can be determined through experiments.But (4) is deduced from the assumption that the molecules do not interact with each other, so it is only applicable to the system with low temperature. However, it is difficult to determine the dielectric constant and density of the gas phase, and some substances can not even make it in a stable gas phase. Therefore, a solution method was later proposed to solve this difficulty. The basic idea of solution method is that in a nonpolar solvent solution of infinite dilution in the state, and the solute molecule is similar, so the molar polarization EMBED Equation.3 infinite dilution of the solute can be regarded as a type of P (4).Hyde (Hedestran) firstly, Zittrain approximate formula of dilute solutionEMBED Equation.3 (5)EMBED Equation.3 (6)Based on the additivity of the solution, the formula for the molar polarization of solute in infinite dilution is derivedEMBED Equation.3 (7)The above (5), (6), (7) type, EMBED Equation.3, EMBED Equation.3 is the solution of the dielectric constant and density, EMBED Equation.3, EMBED Equation.3 is the solute molar mass and molar fraction, EMBED Equation.3, EMBED Equation.3 and EMBED Equation.3 respectively, dielectric constant, density and molar mass of the solvent. EMBED Equation.3, EMBED Equation.3 and EMBED Equation.3 respectively in EMBED Equation.3 and EMBED Equation.3 EMBED Equation.3 on the slope of the line constant.As mentioned above, the molar induced polarization of polar molecules, EMBED, Equation.3 = EMBED, Equation.3 + EMBED, Equation.3, can be measured at an electric field of infrared frequencies. But in experiments, it is difficult to do this because of the limitation of the conditions. Therefore, the electronic polarizability of polar molecules is always measured in high frequency electric field EMBED Equation.3.According to the electromagnetic theory of light, in the action of high frequency electric field with the same frequency, the dielectric constant of EMBED transparent material Equation.3 and refractive index n was EMBED Equation.3 (8)The habit of using molar refraction R2 to represent the high frequency region measured polarization, because the EMBED Equation.3 = 0, EMBED Equation.3 =0, R2 = EMBED Equation.3 = EMBED Equation.3 (9)Approximate formulas are also found for dilute solutionsEMBED Equation.3 (10)Similarly, formulas for the molar refraction of solutes from infinite dilution can be derived from (9) formulaeEMBED, Equation.3, EMBED, Equation.3 (11)The above (10), (11) type, EMBED Equation.3 is the refractive index of the solution, N1 is the solvent refractive index, gamma is constant and EMBED Equation.3EMBED Equation.3 on line slope.Three. Determination of dipole momentConsidering that atomic polarizability is usually only 5% to 10% of electron polarizability, and that EMBED Equation.3 is much larger than EMBED Equation.3, atomic polarization is often neglected.Available from (2), (3), (7) and (11) formsEMBED, Equation.3, EMBED, Equation.3 (12)The formula combines the microscopic properties of matter molecules, dipole moments, and their macroscopic properties, dielectric constants, densities, and refractive indices. The permanent dipole moments of a molecule can be calculated by the following simplified formulaEMBED Equation.3 (13)In some cases, if you need to consider the EMBED Equation.3 impact, just make a partial revision of the EMBED Equation.3.The method of determining the dipole moment of polar molecules is called the solution method. There is a deviation between the dipole moment measured by the solution method and the true value measured by the gas phase, which is caused by the solvation of the non-polar solvent and the polar solute molecule,This deviation is called the solvent effect of measuring dipole moment by solution method". Ross and Ross (Sack) have studied the solvent effect and deduced the correction formula. Interested readers can read the reference material.In addition, there are many experimental methods for measuring dipole moment, such as temperature method, molecular beam method, molecular spectrum method, and stark method using microwave spectrum.Four. Determination of dielectric constantDielectric constant is obtained by measuring capacitance.The methods of measuring capacitance are bridge method, beat frequency method and harmonic method. The latter have good anti-interference performance and high accuracy, but the price of the instrument is more expensive. In this experiment, the bridge method is adopted, and the CC - 6 type small capacitance measuring instrument is adopted, which is matched with the electric dissolving pool produced by the scientific and educational instrument factory of Fudan University.When the capacitance is between the poles of the vacuum andfills a substance, the capacitances are C. And Cx, the dielectric constant of a substance, EMBED, Equation.3, and capacitance are related toEMBED Equation.3 (14)The EMBED, Equation.3 and EMBED Equation.3 in the formula are respectively the capacitance of the vacuum and the substance.When the capacitor pool is inserted into the small capacitance measuring instrument to measure the capacitance, the actual measured capacitance is composed of the capacitance between the poles of the capacitor pool and the distributed capacitance Cd in the whole testing system. Cd is a constant value, which is called the background value of an instrument. It should be deducted when measuring, otherwise the error will be introduced. Therefore, the background value Cd must be found and deducted in future measurements.Instrument ReagentAbbe refractometer 1, electric blower 1CC6 small capacitance measuring instrument type 1 volumetric flask (50 fillJ) 4The capacitor pool L is only ethyl acetate (analytically pure)Super constant temperature trough 1 carbon tetrachloride (analytical purity)Experiment procedurePreparation of solution10ml carbon tetrachloride was removed by pipette and placed in four volumetric flasks. Then 0.2 and 0.4, 0.6 and 0.8ml ethyl acetate were removed from the liquid exchange tubes and then placed in four volumetric flasks. 4 different concentrations of ethyl acetate and one carbon tetrachloride solution were prepared. In operation, attention should be paid to the prevention of volatilization of solutes and solvents and the absorption of polar water vapor. For this solution, the stopper shall be quickly put in a dry container.Two refractive index determinationThe refractive index of carbon tetrachloride and its prepared solutions were determined by Abbe refractometer at (25, 0.1) centigrade. The sample should be added three times each time, three data are read each time, and then the average value is taken.Three. Determination of dielectric constant1. capacitors Cd and C. This experiment uses carbon tetrachloride as the standard material, and the temperature formula of its dielectric constant isEMBED Equation.3 = 2.238 - 0.0020 (T - 20) (15)The T is constant temperature (DEG C). EMBED Equation.3 shouldbe 2.228 at 25 degrees centigrade.Blow the gap between the poles of the capacitor pool with the ear ball and spin it on the metal cover. After opening the power supply, the capacitor pool is connected with the small capacitance measuring instrument after the zero calibration, and the constant temperature bath guide pipe is connected, so that the capacitor is in constant temperature (2, 0.1) DEG C. Wait until the display capacitor no longer rises (if the value is unstable and reads the maximum displayed) to read the value. Repeated measurements were taken three times, with an average of three Equation.3 for EMBED measurements.The pure carbon tetrachloride is added to the capacitor pool from the center of the metal cap to the liquid level by more than two electrodes and covered with a plastic stopper to prevent liquid evaporation. After a few minutes of constant temperature, the capacitance value is measured by the same method. Then open the metal lid, tilt the carbon tetrachloride between the diodes (fall into the recycle bottle), and reload the sample again to measure the value of the capacitor. The average value of the two measurements is EMBED Equation.3.2. determination of solution capacitance: the method of measurement is the same as that of pure carbon tetrachloride. However, in order to verify that the residual liquid between the electrodes of the capacitor cell has indeed been removed before measuring, the capacitance in the air medium can be measured first. If the capacitor value is on the high side, the acetone solution will be used to wash it, and then blow it in the ear bulb capacitor pool before adding a new solution. Eachsolution should be repeated two times, the difference between the data should be less than 0.05pF, or continue to retest. The measured capacitance readings take the average value minus Cd, that is, the capacitance value of the solution is C. Because the solution caused by the volatile concentration change, so the sample moves quickly, after adding sample plastic plug to plug.3. density of solution: EMBED Equation.3EMBED Equation.3The density of EMBED Equation.3 is 0 degrees centigrade,EMBED 3为T℃时的密度,单位为:EMBED 3。
实验十五偶极矩的测定溶液法
实验十五 偶极矩的测定──溶液法一、实验目的1.用溶液法测定乙酸乙酯的偶极矩。
2.了解用溶液法测定偶极矩的原理、方法和计算,并了解偶极矩与分子电性质的关系。
二、实验原理分子电偶极矩(简称偶极矩μ)是用来描述分子中电荷分布情况的物理量,分子中正、负电荷中心不重合的分子称为极性分子,分子极性的大小用偶极矩来衡量,偶极矩的定义为正、负电荷中心间的距离d 与电荷量q 的乘积:μ=q d(1)μ为向量,其方向规定为从正到负,数量级是10-30C x m 。
通过偶极矩的测定,可以了解分子结构中有关电子云的分布,分子的对称性,以及判别几何异构体和分子的立体结构等。
无论是极性分子还是非极性分子,在外电场的作用下,均会发生极化。
其极化的大小用分子极化率来衡量,它等于定温时单位电场强度下的平均偶极矩。
对于极性分子,则有:α=α原子+α电子+α取向(2)α原子和α电子分别称为原子极化率和电子极化率,其中α原子+α电子又称为变形极化率,而α取向为取向极化率,且有:α取向=kT32μ(3)式中:μ──分子的永久偶极矩;k ──玻尔兹曼常数;T ── 热力学温度。
由克劳修斯-莫索第-德拜方程,分子极化率α与电介质的介电常数ε和ρ之间的关系为:kTN N N N M P A A A A 29434343421μπαπαπαπρεε••+•=•=•+−=+电子原子(4)或简单地表示为:P =P 原子+P 电子+P 取向 (5)式中:P ──摩尔极化度,即单位场强下,1摩尔电介质的体积内偶极矩之和;N A ──阿佛加德罗常数;M ──摩尔质量;ρ──密度。
必须注意(4)式和(5)式只有在低频电场(频率<1010s -1)才成立。
若在高频电场(频率ν>1015s -1,即可见光及紫外光区)时,则P 原子 , P 取向均为零,只有P 电子一项,且ε=n 2(n 为电介质的折光率),所以:电子电子απρ•=•+−=≈=A N M n n P R P 342122 (6)式中:R ──摩尔折射度(在高频电场测得的极化度,习惯上用摩尔折射度来表示)。
溶液法测定偶极矩
果外电场 是交变电 场,极性 分子的极 化情况则 与交变电 场的频率 有关
Northwest University
化学国家级实验教学示范中心
当频率增加到中频(红外频率)时,电场的交变周期 小于分子的偶极矩的弛豫时间,极性分子的转向运动跟不 上电场的变化,即极性分子来不及沿电场定向,故P转向=0。 此时极性分子的摩尔极化度等于摩尔诱导极化度P诱导 当交变电场的频率进一步增加到大于 1015 s-1 的高频 (可见光和紫外频率)时,极性分子的转向运动和分子 骨架变形都跟不上电场的变化,此时极性分子的摩尔极 化度等于电子极化度P电子。
Northwest University
化学国家级实验教学示范中心
海德斯特兰(Hedestran)首先利用稀溶液的近 似公式 s 1(1 x 2 )
s 1(1 x 2 )
再根据溶液的加和性,推导出无限稀释时溶质摩尔极化度的公式
P P
2
31 M 1 1 1 M 2 M 1 lim P2 2 x 2 0 1 2 1 (1 2) 1
P转向与永久偶极矩 μ平方成正比,与 热力学温度T成反 比。
Northwest University
化学国家级实验教学示范中心
在外电场作用下,极性 分子或非极性分子都会产 生电子云对分子骨架的相 对移动,分子骨架也会发 生变形,这种现象称为诱 导极化或变形极化 ,用摩 尔诱导极化度 P 诱 导 来衡量。
P诱导可分为两项, 电子极化度和原 子极化度,与外 电场强度成正比, 与温度无关。
Northwest University
化学国家级实验教学示范中心
频率小于 1010 s-1 的低频电场或静电场中, 极性分子所产生的摩尔极化度是转向极化、 电子极化和原子极化的总和,即:
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
溶液法测定极性分子的偶极矩I. 目的与要求一、 用溶液法测定乙酸乙酯的偶极矩二、 了解偶极矩与分子电性质的关系三、 掌握溶液法测定偶极矩的实验技术I I. 基本原理一、偶极矩与极化度分子结构可以近似地被石成是由电子。
和对于骨架(原子核及内层电子)所构成的。
由于分子空间构型的不同,其正、负电荷中心可能是重合的,也可能不重合,前者称为非极性分子,后者称为极性分子。
图1 电偶极矩示意图1912年,德拜(Debye )提出―偶极矩‖μ的概念来度量分子极性的大小,如图1所示,其定义是 d q ⋅=μ (1)式中 q 是正、负电荷中心所带的电荷量,d 为正、负电荷中心之间的距离,μ是一个向量,其方向规定从正到负。
因分子中原子间距离的数量级为1010-m ,电荷的数量级为2010-C ,所以偶极矩的数量级是3010-C·m 。
通过偶极矩的测定可以了解分子结构中有关电子云的分布和分子的对称性等情况,还可以用来判别几何异构体和分子的立体结构等。
极性分子具有永久偶极矩,但由于分子的热运动,偶极矩指向各个方向的机会相同,所以偶极矩的统计值等于零。
若将极性分子置于均匀的电场中,则偶极矩在电场的作用下会趋向电场方向排列。
这时我们称这些分子被极化了,极化的程度可用摩尔转向极化度转向P 来衡量。
转向P 与永久偶极矩平方成正比,与热力学温度T 成反比kTL kT L P 2294334μπμπ=⋅=转向 (2) 式中k 为玻耳兹曼常数,L 为阿伏加德罗常数。
在外电场作用下,不论极性分子或非极性分子都会发生电子云对分子骨架的相对移动,分子骨架也会发生变形,这种现象称为诱导极化或变形极化,用摩尔诱导极化度诱导P 来衡量。
显然,诱导P 可分为二项,即电子极化度电子P ,和原子极化度原子P ,因此诱导P = 电子P + 原子P 。
诱导P 与外电场强度成正比,与温度无关。
如果外电场是交变电场,极性分子的极化情况则与交变电场的频率有关。
当处于频率小于1010-s -1的低频电场或静电场中,极性分子所产生的摩尔极化度P 是转向极化、电子极化和原子极化的总和P = 转向P + 电子P + 原子P (3)当频率增加到1210-~1410-s -1的中频(红外频率)时,电场的交变周期小于分子偶极矩的弛豫时间,极性分子的转向运动跟不上电场的变化,即极性分子来不及沿电场定向,故转向P = 0。
此时极性分子的摩尔极化度等于摩尔诱导极化度诱导P 。
当交变电场的频率进一步增加到大于1510-s -1的高频(可见光和紫外频率)时,极性分子的转向运动和分子骨架变形都跟不上电场的变化,此时极性分子的摩尔极化度等于电子极化度电子P 。
因此,原则上只要在低频电场下测得极性分子的摩尔极化度P ,在红外频率下测得极性分子的摩尔诱导极化度诱导P ,两者相减得到极性分子的摩尔转向极化度转向P ,然后代人(2)式就可算出极性分子的永久偶极矩μ来。
二、极化度的测定克劳修斯、莫索蒂和德拜(Clausius -Mosotti -Debye )从电磁理论得到了摩尔极化度P 与介电常数ε之间的关系式ρεεM P ⋅+-=21 (4) 式中,M 为被测物质的摩尔质量,ρ是该物质的密度,ε可以通过实验测定。
但(4)式是假定分子与分子间无相互作用而推导得到的,所以它只适用于温度不太低的气相体系。
然而测定气相的介电常数和密度,在实验上困难较大,某些物质甚至根本无法使其处于稳定的气相状态。
因此后来提出了一种溶液法来解决这一困难。
溶液法的基本想法是,在无限稀释的非极性溶剂的溶液中,溶质分子所处的状态和气相时相近,于是无限稀释溶液中溶质的摩尔极化度∞2P 就可以看作为(4)式中的P 。
海德斯特兰(Hedestran )首先利用稀溶液的近似公式 ()211x αεε+=溶 (5)()211x βρρ+=溶 (6)再根据溶液的加和性,推导出无限稀释时溶质摩尔极化度的公式()11211112112022123lim 2ρβεερεαεM M M P P P x -⋅+-+⋅+===→∞ (7) 上述(5)、(6)、(7)式中,溶ε、溶ρ是溶液的介电常数和密度,2M 、2x 是溶质的摩尔质量和摩尔分数,1ε、1ρ和1M 分别是溶剂的介电常数、密度和摩尔质量,α、β在是分别与溶ε-2x 和溶ρ-2x 直线斜率有关的常数。
上面已经提到,在红外频率的电场下可以测得极性分子的摩尔诱导极化度诱导P = 电子P + 原子P 。
但在实验上由于条件的限制,很难做到这一点,所以一般总是在高频电场下测定极性分子的电子极化度电子P 。
根据光的电磁理论,在同一频率的高频电场作用下,透明物质的介电常数ε与折光率n 的关系为 2n =ε (8)习惯上用摩尔折射度R 2来表示高频区测得的极化度,因为此时转向P = 0,电子P =0,则 R 2 =电子P = ρM n n ⋅+-2122 (9) 在稀溶液情况下也存在近似公式()211x n n γ+=溶 (10) 同样,从(9)式可以推导得无限稀释时溶质的摩尔折射度的公式 电子P ()122112111221212022621lim 2ργρβ++-⋅+-===→∞n M n M M n n R R x (11) 上述(10)、(11)式中,溶n 是溶液的折光率,n 1是溶剂的折光率,γ是与溶n -2x 直线斜率有关的常数。
三、偶极矩的测定考虑到原子极化度通常只有电子极化度的5%~10%,而且转向P 又比电子P 大得多,故常常忽视原子极化度。
从(2)、(3)、(7)和(11)式可得转向P kT L R P 22294μπ=-=∞∞(12) 上式把物质分子的微观性质偶极矩和它的宏观性质介电常数、密度和折射率联系起来,分子的永久偶极矩就可用下面简化式计算()m C T R P ⋅-⨯=∞∞-22301004274.0μ (13)在某种情况下,若需要考虑电子P 影响时,只需对∞2R 作部分修正就行了。
上述测求极性分子偶极矩的方法称为溶液法。
溶液法测得的溶质偶极矩与气相测得的真实值间存在偏差,造成这种现象的原因是非极性溶剂与极性溶质分子相互间的作用—―溶剂化‖作用,这种偏差现象称为溶液法测量偶极矩的―溶剂效应‖。
罗斯(Ross )和萨克(Sack )等人曾对溶剂效应开展了研究,并推导出校正公式,有兴趣的读者可阅读有关参考资料。
此外,测定偶极矩的实验方法还有多种,如温度法、分子束法、分子光谱法以及利用微波谱的斯塔克法等,这里就不一一介绍了。
四、介电常数的测定介电常数是通过测量电容计算而得到的。
测量电容的方法一般有电桥法、拍频法和谐振法。
后两者抗干扰性能好、精度高,但仪器价格较贵。
本实验采用电桥法,选用CC -6型小电容测量仪,将其与复旦大学科教仪器厂生产的电溶池配套使用。
电容池两极间真空时和充满某物质时电容分别为C 。
和Cx ,则某物质的介电常数ε与电容的关系为0C C x x ==εεε (14) 式中0ε和x ε分别为真空和该物质的电容率。
当将电容池插在小电容测量仪上测量电容时,实际测量所得的电容应是电容池两极间的电容和整个测试系统中的分布电容C d 并联构成。
C d 是一个恒定值,称为仪器的本底值,在测量时应予扣除,否则会引进误差,因此必须先求出本底值C d ,并在以后的各次测量中予以扣除。
Ⅲ.仪器 试剂阿贝折光仪 1台 电吹风 1只CC -6型小电容测量仪 1台 容量瓶(50 fillJ ) 4只电容池 l 只 乙酸乙酯(分析纯)超级恒温槽 1台 四氯化碳(分析纯)Ⅳ.实验步骤一、溶液配制用称重法配制4个不同浓度的乙酸乙酯—四氯化碳溶液,将4个50ml 的容量瓶干燥、称重;用移液管分别移取5.00 ml ,6.00 ml , 7.00 ml , 8.00 ml 乙酸乙酯于上述各干燥容量瓶中,称重后加入CCl 4至刻度,称重。
计算出每个溶液的摩尔浓度。
二、折光率测定在室温下用阿贝折光仪测定四氯化碳及各样品的折光率。
测定时注意各样品需加样三次,每次读取三个数据,然后取平均值。
三、介电常数测定1.电容C d 和C 。
的测定:本实验采用四氯化碳作为标准物质,其介电常数的温度公式为标ε= 2.238 – 0.0020(t —20) (15)式中t 为恒温温度(℃)。
25℃时标ε应为2.228。
用洗耳球将电容池两极间的间隙吹干,旋上金属盖。
开通电源,校零后将电容池与小电容测量仪相连接,接通恒温浴导油管,使电容他恒温在(2.0士0.1)℃。
待到显示电容不再上升(如果数值不稳定,读取显示的最大值),读取数值。
重复测量三次,取三次测量的平均值为'0C 。
用液管将纯四氯化碳从金属盖的中间口加人到电容池中去,使液面超过二电极,并盖上塑料塞,以防液体挥发。
恒温数分钟后,同上法测量电容值。
然后打开金属盖,倾去二极间的四氯化碳(倒在回收瓶中),重新装样再次测量电容值。
取两次测量的平均值为'标C 。
2.溶液电容的测定:测定方法与纯四氯化碳的测量相同。
但在进行测定前,为了证实电容池电极间的残余液确已除净,可先测量以空气为介质时的电容值。
如电容值偏高,则应用丙酮溶液润洗,再以洗耳球电容池吹干,方可加入新的溶液。
每个溶液均应重复测定两次,其数据的差值应小于0.05pF ,否则要继续复测。
所测电容读数取平均值,减去C d ,即为溶液的电容值C 溶。
由于溶液易挥发而造成浓度改变,故加样时动作要迅速,加样后塑料塞要塞紧。
V .数据处理一、按溶液配制的实测质量,计算四个溶液的实际浓度2x 。
二、计算C 。
、C d 和各溶液的C 溶值,求出各溶液的介电常数ε溶;作ε溶-2x 图,由直线斜率求算α值。
三、计算纯四氯化碳及各溶液的密度,作ρ-2x 图,由直线斜率求算β值。
四、作n 溶-2x 图,由直线斜率计算γ值。
五、将ρ2、ε1、α和β值代人(7)式计算∞2P 。
六、将ρ1、n 1、β和γ值代人(11)式计算∞2R 。
七、将∞2P 、∞2R 值代人式(13)即可计算乙酸乙酯分子的偶极矩μ值。
八、文献值Ⅵ. 思考一、分析本实验误差的主要来源,如何改进?二、试说明溶液法测量极性分子永久偶极矩的要点,有何基本假定,推导公式时作了哪些近似?三、如何利用溶液法测量偶极矩的―溶剂效应‖来研究极性溶质分子与非极性溶剂的相互作用?测定电容方法如下:(1)准备:打开小电容测试仪前面板的电源开关,预热5分钟。
电容池使用前,应打开加料盖,用丙酮对内外电极间隙进行数次冲洗,并用电吹风吹干。
用配套测试线将数字小电容测试仪的―电容池座‖C2插座与电容池的内电极插座相连;将另一根测试线的一端插入小电容测试仪的―电容池‖C1插座,插入后顺时针旋转一下以防脱落,另一端悬空。
待显示稳定后,按一下采零键,显示器显示―00.00‖。