9300产品安装手册

合集下载

Cisco Nexus 9300 ACI 固定拓扑 spine 交换机产品简介说明书

Cisco Nexus 9300 ACI 固定拓扑 spine 交换机产品简介说明书

Data SheetCisco Nexus 9300 ACI Fixed Spine SwitchesProduct OverviewIndustry shifts are redefining IT at all levels. On-premise IT consumption models are shifting to cloud-based services. IT as a Service (IaaS) is supplanted by applications as a service. Separate development and operations are moving toward integrated Development and Operations (DevOps). Device-centric management models are migrating to application-centric management.Business agility requires application agility, so IT teams need to provision applications in hours instead of months. Resources need to scale up (or down) in minutes, not hours. Traditional approaches take a siloed operational view, with no common operational model for the application, network, security, and cloud teams. A common operational model delivers application agility, simplified operations, assured performance, and scale.The Solution: An Application-Centric Approach to Managing Your InfrastructureCisco® Application Centric Infrastructure (ACI) is a holistic architecture with centralized automation and policy-based application profiles. The Cisco ACI fabric is designed from the foundation to support emerging industry demands while maintaining a migration path for architecture already in place. The fabric is designed to support the industry move to management automation, programmatic policy, and dynamic “workload-anywhere” models. The Cisco ACI fabric accomplishes this with a combination of hardware, policy-based control systems, and software closely coupled to provide advantages not possible in other models.The fabric consists of three major components: the Cisco Application Policy Infrastructure Controller (APIC), spine switches, and leaf switches. These three components handle both the application of network policy and the delivery of packets. Organizations can use the ACI-ready Cisco Nexus® 9000 Series Switches as spine or leaf switches to take full advantage of an automated, policy-based, systems management approach. The Cisco Nexus 9300 Series Switches include both spine and leaf switches. For detailed information, please refer here.Switch ModelsThe Cisco Nexus 9336PQ ACI Spine Switch is a 2-Rack-Unit (2RU) spine switch for Cisco ACI that supports2.88 Tbps of bandwidth and 2.3 billion packets per second (bpps) across 36 fixed 40 QSFP+ ports (Figure 1). Cisco Nexus 9300 platform leaf switches are Layer 2 and 3 nonblocking 10 and 40 Gigabit Ethernet switches with up to 2.56 Terabits per second (Tbps) of internal bandwidth.Figure 1.Cisco Nexus 9336PQ SwitchThe Cisco Nexus 9364C ACI Spine Switch is a 2-Rack-Unit (2RU) spine switch for Cisco ACI that supports 12.84 Tbps of bandwidth and 4.3 bpps across 64 fixed 40/100G QSFP28 ports and 2 fixed 1/10G SFP+ ports(Figure 2). Breakout is not supported on ports 1 to 64. The last 16 ports marked in green support wire-rate MACsec encryption 1.Figure 2.Cisco Nexus 9364C SwitchThe Cisco Nexus 9332C is the smallest form-factor 1-Rack-Unit (1RU) spine switch for Cisco ACI that supports 6.4 Tbps of bandwidth and 2.3 bpps across 32 fixed 40/100G QSFP28 ports and 2 fixed 1/10G SFP+ ports(Figure 3). Breakout is not supported on ports 1 to 32. The last 8 ports marked in green support wire-rate MACsec encryption 2.Figure 3.Cisco Nexus 9332C SwitchSpecificationsTable 1 lists the specifications for the Cisco Nexus 9336PQ switch. (Please check Cisco ACI software release notes for feature support information.)Table 1.Cisco Nexus 9300 ACI Spine Switch Specifications1Software is expected in a future release. Please check the latest software update here . 2Software is expected in a future release. Please check the latest software update .●USB: 2 ports●RS-232 serial console ports: 1●Management ports: 1 x10/100/1000BASE-TPower and Cooling ●Power: 1200W AC, 930W DCor 1200W HVAC/HVDC●Input voltage: 100 to 240V*AC or -40V to -72V DC(min-max), -48V to -60V DC(nominal)*Supports input voltage of100-120V for a max output of800W; 200-240V for a maxoutput of 1200W●Frequency: 50 to 60 Hz (AC)●Efficiency: 90% or greater(20 to 100% load)●RoHS compliance: Yes●Hot swappable: Yes●Port-side intake or port-sideexhale options●Typical power: 400W (AC)●Maximum power: 660W (AC)●Power: 1200W AC, 930W DC3 or 1200WHVAC/HVDC●Input voltage: 100 to 240V* AC or -40V to-72V DC (min-max), -48V to -60V DC(nominal)*Supports input voltage of 100-120V for amax output of 800W; 200-240V for a maxoutput of 1200W; PSU redundancy is notsupported when used in 100-120V●Frequency: 50 to 60 Hz (AC)●Efficiency: 90% or greater (20 to 100%load)●RoHS compliance: Yes●Hot swappable: Yes●Port-side intake or port-side exhaleoptions●Typical power: 429W (AC)●Maximum power: 1245W (AC)●Power: 1100W AC, 1100 DC or 1100WHVAC/HVDC●Input voltage: 100 to 240V* AC or -40V to -72V DC (min-max), -48V to -60V DC(nominal)*Supports input voltage of 100-120V for amax output of 800W; 200-240V for a maxoutput of 1200W●Frequency: 50 to 60 Hz (AC)●Efficiency: 90% or greater(20 to 100% load)●RoHS compliance: Yes●Hot swappable: Yes●Port-side intake or port-side exhale options●Typical power: 296W (AC)●Maximum power: 700W (AC)Environme ntal ●Physical (H x W x D): 3.5 x17.5 x 22.5 in. (8.9 x 44.5 x57.1 cm)●Weight: 34.4 lb●Operating temperature: 32 to104°F (0 to 40°C)●Nonoperating (storage)temperature: -40 to 158°F (-40to 70°C)●Humidity: 5 to 95%(noncondensing)●Altitude: 0 to 13,123 ft (0 to4000m)●Physical (H x W x D): 3.38 x 17.37 x22.27 in. (8.59 x 44.13 x 56.58 cm)●Weight: 36.9lb (16.74kg) with powersupplies and fans, 27.4 lb (12.43kg)without power supplies and fans●Operating temperature: 32 to 104°F (0 to40°C)●Nonoperating (storage) temperature: -40to 158°F(-40 to 70°C)●Humidity: 5 to 85% (noncondensing)●Altitude: 0 to 13,123 ft (0 to 4000m)●Physical (H x W x D): 1.7 x 17.3 x 22.9 in.(4.4 x 43.9 x 58.1 cm)●Weight: 25.1lb (11.4kg) with powersupplies and fans, 19 lb (8.6kg) withoutpower supplies and fans●Operating temperature: 32 to 104°F (0 to40°C)●Nonoperating (storage) temperature: -40 to158°F (-40 to 70°C)●Humidity: 5 to 85% (noncondensing)●Altitude: 0 to 13,123 ft (0 to 4000m)Acoustics ●Fan speed at 40%: 64.4 dBA●Fan speed at 70%: 79.6 dBA●Fan speed at 100%: 89.8 dBA ●Fan speed at 40%: 76.7 dBA●Fan speed at 70%: 88.7 dBA●Fan speed at 100%: 97.4 dBA●Fan speed at 50%: 76.4 dBA●Fan speed at 70%: 83.3 dBA●Fan speed at 100%: 92.1 dBAMTBF ●242,000 hours ●257,860 hours ●363,500 hours3 930W-DC PSU is supported in redundancy mode if 3.5W QSFP+ modules or Passive QSFP cables are used & the system is used in 40C ambient temp or less; for other optics or higher ambient temps, 930W-DC is suppor ted with 2 PSU’s innon-redundancy mode only.Cisco Nexus 9300 ACI Spine Switch Deployment ScenariosThe Nexus 9300 ACI spine switch along with Nexus 9300 leaf nodes enable an automated and policy driven ACI architecture. The Cisco Nexus 9300 ACI spine switch offers advanced scalability in the smallest spine switch form factor, and enables connectivity to up-to 64 Cisco Nexus 9300 leaf switches with its high port density of 64 40/100 GbE ports and 12.84 Tbps throughput. The degree of redundancy in leaf-and-spine architectures delivers increased availability with a high level of flexibility in workload placement (Figure 3).Figure 4. Cisco Nexus 9300 Platform in a Leaf-and-Spine ArchitectureSoftware RequirementsFor the latest software release information and recommendations, please refer to the product bulletin athttps:///go/aci and Cisco Feature Navigator.Regulatory Standards ComplianceTable 2 summarizes regulatory standards compliance for the Cisco Nexus 9300 Spine switch.Table 2. Regulatory Standards Compliance: Safety and EMCSupported Optics PluggableFor details on the optical modules available and the minimum software release required for each supported optical module, visithttps:///en/US/products/hw/modules/ps5455/products_device_support_tables_list.html. Ordering InformationTable 3 presents ordering information for the Cisco Nexus 9300 ACI Spine Switch.Table 3. Ordering InformationWarrantyThe Cisco Nexus 9300 switch has a 1-year limited hardware warranty. The warranty includes hardware replacement with a 10-day turnaround from receipt of a Return Materials Authorization (RMA).Service and SupportCisco offers a wide range of services to help accelerate your success in deploying and optimizing the Cisco Nexus 9300 switch in your data center. The innovative Cisco Services offerings are delivered through a unique combination of people, processes, tools, and partners and are focused on helping you increase operation efficiency and improve your data center network. Cisco Advanced Services uses an architecture-led approach to help you align your data center infrastructure with your business goals and achieve long-term value. Cisco SMARTnet®Service helps you resolve mission-critical problems with direct access at any time to Cisco network experts and award-winning resources.Cisco CapitalFlexible payment solutions to help you achieve your objectives.Cisco Capital makes it easier to get the right technology to achieve your objectives, enable business transformation and help you stay competitive. We can help you reduce the total cost of ownership, conserve capital, and accelerate growth. In more than 100 countries, our flexible payment solutions can help you acquire hardware, software, services and complementary third-party equipment in easy, predictable payments. Learn more.For More InformationFor more information on the Cisco Nexus 9000 Series and for latest software release information and recommendations, please visit https:///go/nexus9000.。

Philips 9300智能推杆锁说明书

Philips 9300智能推杆锁说明书

9000 seriesIntuitive push-pull useAuto Locking FunctionIndoor infrared sensor unlockLink with IoT gatewayDDL193LAFCG Smart lifeSafety under control in the age of IoTEnjoy the extreme convenience brought by the intuitive fingerprint verification, fullauto switch, and infrared sensor. Link with IoT gateway and smart door viewermakes security assured at your fingers.Extraordinary design brings outstanding experienceUnlock swiftly at one goMultiple protection in one for overall home safetyInstant alert upon inside unlockingProtect your password security in real timeHigher lock reliability and better home securityCare more about safety of children and petsLife is more than convenientUnlocking once detects the handEnjoy the reassurance after closing the doorSmart life lock with excellencebetter security assured by IoTProvides linkage to future lifeHighlightsAuto lockingPhilips 9300 push-pull smart door lock employs full automatic mortise. Without the need for any extra action, the deadbolt will spontaneously pop up after closing the door. If the door is not locked up, the mortise will give an alert to remind you of the door lock status.Gateway & smart door viewer*You can remotely view unlocking records and distribute a one-time PIN code at any time via the gateway. The smart door viewer will take photos or videos, then upload them to the App under the abnormal alert, when it is binding with the door lock, so that users could get to know various situations from the inside and outside of the door.Indoor infrared sensorFeatures with the touch sensor and infrared sensor, when touching the touch sensor and the infrared sensor detects an obstruction, the door will be unlocked.Instinctive fingerprintThe fingerprint sensor is integrated with the push-pull handle so that when you hold the handle, your finger will naturally fall on the sensor. You can simply reach out and touch the sensor, then push to open after a successful fingerprint verification. The one-step unlocking feature will bring you a fast and convenient door opening experience.Wireless network extensionWith the connection to the wireless network,you can remotely manage the access of door locks, monitor the status of door locks in real-time, view the access logs at any time, and achieve personalized management of smart door locks.C-grade lock cylinderThe lock cylinder is the key component that controls the opening of the lock. The C-grade lock cylinder employs multiple anti-thefttechnologies with a unique design of pin tumbler and vane structure, that can provide high deterrence against technical lock-picking.Functional buttons[Open]: Double click the button within one second could unlock the door, which prevents accidentally unlocking by children and pets effectively. [Close]: Click once on the button could lock the door. Long pressing the button could enable inside deadlock. You could use the master PIN code or mechanical key to disable inside deadlocking. Simultaneously press the [Open] and [Close] buttons could enable or disable the inductive unlocking function.Hidden PIN codeFeatures with hidden PIN code technology,Philips smart door lock allows you to enter any random number combinations to successfully get identified as there is consecutive input of the correct password. This feature caneffectively prevent peeping and disclosing your real password.SpecificationsAccess SolutionBluetoothCard/Key TagFingerprintMechanical KeyPassword/PIN CodeSmart Lock FunctionsAlarm Function: Anti-prying alarm, Outside forced lock alarmLocking Function: Electronic deadlock, System lockingMortise: Full auto mortiseSafety Function: Dual verification, Fake PIN code, Outside forced lock function, Safe handle funtionEasy OperationIndicator: Door locks status prompt, Low battery prompt, Mute status prompt, Outside forced lock prompt, System locking prompt Voice Guide: Human voice guideDesign & AppearanceColor: Red copperEmergency Escape Design: Indoor fast opening mortise Ergonomic Design: Push-pull handle designHandle: Push-pull handleMain Material: Zinc alloySurface Processing: ElectroplatingFingerprint Sensor: SemiconductorLock CapacityCard/Key Tag: Up to 100Fingerprint: Up to 100Master PIN Code: 1One-time PIN Code: 1User PIN Code: Up to 10ModeOperationg Mode: Auto mode, Manual modeSystem Setup Mode: Dual verification mode,Normal modePower SpecificationBattery Type: Alkaline BatteriesEmergency Power Supply: 5V power bankMaximum Batteries Capacity: 8 batteriesPower Supply: 4 AA batteriesTime of Use: 10 months*Working Voltage: 4.5-6VInstallationDoor Opening Direction: Left inward opening,Left outward opening, Right inward opening,Right outward oepningDoor Thickness: 38-60 mm, 60-90 mm, 90-120 mm, Other range*Door Type: Antitheft door, Copper door,Wooden doorMulti-lock Point: NoAccessory PartsAccessorial Battery: 4 AA alkaline batteriesCertificateDrilling TemplateInstallation AccessoriesMechanical Key: 2 keysMortiseMounting PlateQuick Start GuideCleaning PadSmart Key Tag: 2 cardsUser ManualWarranty Card* The Philips smart door viewer is not an attachedaccessory, which needs to be purchased separately.* May be less depending on the actual usage.* Please contact our service agents or authorized dealersfor other door range.© 2021 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2021‑09‑30 Version: 2.2.112 NC: 8670 001 68016 EAN: 69 71318 50129 6。

NS9300用户手册V1.0

NS9300用户手册V1.0

9 芯片的封装........................................................................................................................................................ 9

存储温度
-65
150

引脚温度 (焊接 10 秒)
260

封装热阻JA ESD 范围
51 4000
℃/W V
HBM 模式
+IT Latch-up
-IT
100
mA 测试标准:JEDEC
STANDARD NO.78A
-100
mA FEBURARY 2006
注1:在极限值之外或任何其他条件下,芯片的工作性能不予保证。 注2:HBM 模式的测试方法是存储在一个的100pF 电容上的电荷通过1.5 KΩ 电阻对每个引
NS9300
四路超低压降恒流型并联 LED 驱动器
NS9300 用户手册 V1.0
深圳市纳芯威科技有限公司 2009 年 7 月
第 1 页 ,共 9 页
目录
NS9300
四路超低压降恒流型并联 LED 驱动器
1 功能说明 ........................................................................................................................................................... 4
NS9300 采用 SOT-23-6 封装,额定的 工作范围为-40℃至 85℃。

SOM-SM9300 核心板 用户手册说明书

SOM-SM9300 核心板 用户手册说明书

SOM-SM9300 核心板用户手册版本1.0–2016年10月版权声明:●SOM-SM9300核心板及其相关知识产权由深圳市英蓓特科技有限公司所有。

●本文档由深圳市英蓓特科技有限公司版权所有,并保留一切权利。

在未经英蓓特公司书面许可的情况下,不得以任何方式或形式来修改、分发或复制本文档的任何部分。

免责声明:●产品附带光盘所提供的程序源代码、软件、资料文档等,深圳市英蓓特有限公司不提供任何类型的担保;不论是明确的,还是隐含的,包括但不限于合适特定用途的保证,全部的风险,由使用者来承担。

版本更新记录:版本更新日期描述1.0 2016-10-18 初始版本目录第1章产品概述 (1)1.1产品简介 (1)1.1.1包装内容 (2)1.1.2产品特性 (2)1.2接口和按钮 ...................................................................... 错误!未定义书签。

1.3系统框图 (4)1.4产品尺寸(mm) (5)第2章硬件系统简介 (6)2.1SOM-SM9300简介 (6)2.2外围芯片介绍 (6)2.2.1MT41K128M16JT-125:K (6)2.2.2EMMC04G-S100 (6)2.2.3MMPF0100NPAEPR2 (7)2.2.4AR8035 (7)2.3接口详述 (7)2.3.1SAMRC接口 (7)技术支持和保修服务 (22)第1章产品概述1.1 产品简介SMARC标准是SGeT组织定义的一个面向低功耗、低成本、高性能的多用途小型计算机模块,设计符合SMARC标准的计算机模块的典型运用方案是ARM SOC或者是与之类似的架构方案如智能电话等。

SMARC标准的计算机模块典型设计功耗在6W以下,不过在一些极端的设计中,SMARC模块可以支持到最高15W的功率设计。

SOM-SM9300是英蓓特推出的基于NXP iMX6系列CPU的SMARC标准模块。

华为S9300系列交换机详细说明书

华为S9300系列交换机详细说明书

Realize Your Potential华为技术有限公司Huawei S9300系列交换机详版彩页01 Huawei S9300系列交换机Huawei S9300系列是华为公司面向融合多业务的网络架构而推出的新一代高端智能T比特核心路由交换机。

该产品基于华为公司智能多层交换的技术理念,在提供稳定、可靠、安全的高性能L2/L3层交换服务S9303 S9306 S9312S9310产品特点S9300敏捷交换机,让网络更敏捷地为业务服务• S9300 敏捷单板内置高速灵活的以太网络处理器ENP,针对以太网专属设计。

借其灵活的报文处理及流量控制能力,深入贴近业务,满足现在及未来的各种挑战,助力客户构建弹性扩展的网络。

ENP芯片采用全可编程架构,可以完全自定义流量的转发模式、转发行为和查找算法。

通过微码编程实现新业务,客户无需更换新的硬件,快速灵活,6个月即可上线,而传统AS I C 芯片采用固定的转发架构和转发流程,新业务无法快速部署,需要等待1~3年的硬件支持。

• 凭借敏捷单板,S9300支持统一用户管理功能,屏蔽了接入层设备能力和接入方式的差异,支持802.1X/ MAC/Portal等多种认证方式,支持对用户进行分组/分域/分时的管理,用户、业务可视可控,实现了从“以设备管理为中心”到“以用户管理为中心”的飞跃。

• 凭借敏捷单板,S9300支持iPCA网络包守恒算法,改变了传统利用模拟流量做故障定位的检测模型,可对任意业务流随时随地逐点检测网络质量,无需额外开销;可在短时间内立刻检测业务闪断性故障,检测直接精准到故障端口,实现从“粗放式运维”到“精准化运维”的大转变。

• 凭借敏捷单板,S9300支持1588v2和同步以太,满足网络设备间的高精度时间同步,相比GPS的时间不同方案,提升安全的同时降低成本。

创新的CSS集群技术• S9300可通过集群卡连接和业务口连接两种方式实现虚拟化。

CSS集群创新性采用交换网集群技术,提供业界主机间最大的320G集群带宽;业务口集群支持成员机通过LPU上的普通业务口连接,将LPU上的业务口配置为堆叠物理成员端口后加入逻辑堆叠端口,通过SFP+光模块和光纤或SFP+堆叠线缆将堆叠物理成员端口连接。

Global Drive 9300-EV 工程型矢量闭环变频器 说明书

Global Drive 9300-EV 工程型矢量闭环变频器 说明书

13253735
G lobal D rive
9300-EV 工程型矢量闭环变频器
本操作说明适用于以下版本的93XX控制器
33.932X-EV1x.1x
对应德文版本︓18/3/1998
版本︓19/3/1998
1.前言
1.1关于此操作手册
●该手册是93XX矢量控制变频器的操作手册,它包含了必要的安全要求,应仔细
阅读。

●93XX矢量控制器操作人员应持有本手册,掌握操作方法并了解注意事项。

●本手册应始终保持完整与可读。

1.1.1术语说明
控制器穴C o ntro lle r雪
在下文中我们简称“93XX矢量控制变频器”为“控制器”。

传动系统穴Drive s yste m雪
在下文中我们简称具有93XX矢量控制变频器和其它Lenze传动元件的系统为“传动系
统”穴Drive system雪
1.2供货范围
●供货范围包括:
-1台矢量控制器93XX
-1本操作手册
-1套附属的配套元件。

●接到供货后,客户应立即检查供货范围与装箱单是否相符。

Lenze公司不负下述赔偿责任:
-明显可见的运输损坏请直接与承运商联系。

-明显可见的缺件与不完整请直接与代理商联系。

1。

NPS9300系列低压装置技术说明书

NPS9300系列低压装置技术说明书

NPS9310系列电动机保护控制装置一、产品用途及特点NPS9310系列智能电动机保护控制装置主要用于690V以下低压电动机控制系统,对电动机的过负荷、短路、超长时间启动、堵转、不平衡、接地、欠压、过压、工艺联锁、绝缘保护等故障引起的危害予以保护,并集合全面的三相电量测量/显示、数字输入/输出与网络通讯于一身。

每个装置具有多种综合电力参数测量功能,既可单独作为电测仪表使用,亦可作为电力综合自动化监控系统之前端,可实现测量、监视、保护、控制等综合功能,该系列测控装置采用了先进的嵌入式控制器,以及全隔离的,高速安全的现场总线技术和大屏幕液显汉字显示,可直接安装在低压开关柜上,通过其标准的RS-485通讯接口及双绞线网络,或通过CAN接口和NPS9930管理机装置通信,轻松实现数据的远方管理及“四遥”功能。

其性能和技术指标处于国内先进水平。

1.1完备的保护功能z电流速断保护z负序过流一段保护z负序过流二段保护z接地保护z过热保护z过热禁止再启动保护z堵转保护z长启动保护z正序过流保护z过负荷保护z欠压保护z PT断线告警z可编程非电量保护1.2装置具有如下功能z8路的开入采集、装置遥信变位、事故遥信z遥控跳、合z交流量采集:三相电压、三相电流、零序电流、有功功率、无功功率、功率因数等z装置自诊断报警z2路脉冲量输入实现外部电度表自动抄表(选配)z1路GPS 硬对时(选配)z电度积分功能,完成电能计量z1路4~20mA直流模拟量输出,替代变送器作为DCS测量接口(选配)z交、直流操作回路(选配)1.3通讯功能z多种通讯接口:RS485、CAN(选配)z多种通讯协议,默认采用标准RS-485总线/MODBUS-RTU协议通信1.4本装置具有如下特点z采用先进的32位工业级摩托罗拉处理器z192*64 大屏幕汉字液晶显示、操作简便直观z采用14位的A/D转换器,各项测量指标轻松达到z配置以大容量的RAM和Flash Memory,可记录8至50个录波报告,记录的事件数不少于1000条z可独立整定32套保护定值,定值切换安全方便z软、硬件冗余设计,抗干扰性能强z完善的软、硬件自检,二级看门狗z全密封嵌入式机箱设计,体积小,重量轻,可直接安装在开关柜上z安全可靠的高速现场总线技术,多种通信接口,多种通信协议z全面、准确、可靠的测控功能z DCS测量接口(4~20mA模拟量输出)(选配)z高精度的时钟芯片,并可选配置GPS硬件对时电路,便于全系统时钟同步装置z电度积分功能,完成电能计量z现场免维护概念¾尽心的电气设计,整机无可调节器件¾高等级、品质保证的元器件选用¾优异的抗干扰性能,组屏或安装于开关柜时不需其它抗干扰模件¾防水、防尘、抗振动的机箱设计¾完善的自诊断功能二、主要技术数据2.1 额定数据直流电源: 220V±20% 或 110V±20%交流电源: 220V±20% 或 110V±20%交流电压: 380/3V,380V,100/3V,100V交流电流:5A或1A频率:50Hz2.2 功率消耗直流回路:≤5W交流电压回路:<0.5V A/相(额定220V时)交流电流回路:<0.5V A/相(额定5A时)<0.1V A/相(额定1A时)2.3 工作环境环境温度:-10℃~+55℃保证正常工作相对湿度:5~95%大气压力:86~106KPa2.4 热稳定性2倍额定电流可连续运行10倍额定电流可连续运行10秒40倍额定电流可连续运行1秒2.5 DCS测量接口输出 (选配)输出范围:4~20mA输出精度:0.5级2.6 接点容量跳、合闸出口(常开接点): 5A,DC 220V(吸合)信号出口(常开接点):5A,DC 220V(吸合)开关量输入:空接点输入,导通电流<10mA2.7 测量精度电压、电流: 1级频率: 0.02HzP、Q、COSΦ: 2级遥信分辨率:<1ms电度积分精度:2级GPS对时精度:<1ms2.8 通讯标准的RS-485通讯接口,MODBUS 通讯协议。

BS-9300系列使用说明书DWZ001-1-1-SM-2

BS-9300系列使用说明书DWZ001-1-1-SM-2

粤制00000103B S -9300系列二次电池性能检测装置使 用 说 明 书广州擎天实业有限公司电工分公司 广州电器科学研究所擎天实业前言感谢客户购置和使用广州擎天实业有限公司的产品。

为了保证安全、正确地使用本产品,敬请用户在操作之前详细阅读本产品说明书的全部内容。

本说明书适用于BS-9300系列二次电池性能检测装置,该系列产品包括BS9300、BS9330、BS9360、BS9300R等多种型号。

本说明书含有开箱检查、安全警告事项、产品的主要技术指标、工作原理、产品使用操作方法和常见故障处理等一系列内容。

在编写过程中,我们已经尽力确保本说明书内容的全面性和准确性。

如果用户在使用过程中有疑问,或者发现有不足和错误之处,欢迎直接与本公司或与本公司授权的代理商进行联系。

用户对说明书如果有不同理解,以本公司技术部的解释为准。

本说明书的内容或个别地方可能发生改变,恕不另行通知。

请用户妥善保管本说明书,以保证仪器的正常使用。

没有本公司书面许可,不得抄袭或改编本说明书的内容,否则被视为侵权。

开箱检查用户在打开产品的包装箱后,请取出装箱清单,并对照本说明书,逐项检查清单所列内容与实物是否完全一致,并核对主机型号是否与你们的订购单是否相同,如果发现有什么不一致的地方,请与本公司或本公司授权的代理商联系。

所有的附件和文件,请妥善保管,以便日后的操作和维护之用。

本成套设备的配件和资料包括:1、BS-9300系列二次电池性能检测装置1台2、夹具箱1个(BS-9360除外)3、测量导线1套4、通讯线1条5、电源线1条6、资料文件夹1个资料文件夹里面夹有的资料包括:1)使用说明书1份2)软件安装盘1盒3)产品合格证1份4)产品保修卡1份5)技术指标说明1份(对于非常规技术指标的产品)安全警告事项在使用本仪器的过程中必须注意下列安全规定,如不遵守本规定,产品功能可能受损并危及人身安全。

注意:★勿在腐蚀性环境中使用本产品不要在含有腐蚀性液体或气体的地方使用本产品,否则将对本产品造成损害。

龙尚U9300C 模块硬件接口手册_V1.2

龙尚U9300C 模块硬件接口手册_V1.2
U9300C 模块硬件接口手册_V1.2
U9300C 模块硬件接口手册_V1.2
共 53 页
第 1 页

重要声明 版权声明 版权所有:龙尚科技(上海)有限公司 本资料及其包含的所有内容为龙尚科技(上海)有限公司所有,受中国法律及适 用之国际公约中有关著作权法律的保护。未经龙尚科技(上海)有限公司书面授 权,任何人不得以任何形式复制、传播、散布、改动或以其它方式使用本资料的 部分或全部内容,违者将被依法追究责任。 不保证声明 龙尚科技 (上海) 有限公司不对此文档中的任何内容作任何明示或暗示的陈述或 保证, 而且不对特定目的的适销性及适用性或者任何间接、特殊或连带的损失承 担任何责任。 保密声明 本文档(包含任何附件)包含的信息是保密信息。接收人了解其获得的本文档是 保密的, 限用于规定的目的外不得用于任何目的,也不得将本文档泄露给任何第 三方。 免责声明 本公司不承担由于客户不正常操作造成的财产或者人身伤害责任。 请客户按照手 册中的技术规格和参考设计开发相应的产品。在未声明之前,本公司有权根据技 术发展的需要对本手册内容进行更改,且更改版本不另行通知。
U9300C 模块硬件接口手册_V1.2 共 53 页 第 3 页
U9300C 模块硬件接口手册_V1.2
共 53 页
第 2 页
目录
1. 引言............................................................................................................................................. 8 1.1. 文档目的...........................................................

BT-9300Z手册

BT-9300Z手册

2
丹东百特科技有限公司 服务热线0415-6184440 网址:
BT-9300Z智能激光粒度仪分布使用手册
终照在探测器中心点上,提高测试结果的准确性。
(4) 独特设计的内置自动循环分散系统。整个系统没有一个按键,循环、搅拌、分散、
进水、排水等所有操作都在电脑控制下自动完成。采用先进的他激电路的超声波
BT-9300Z 型激光粒度分布仪使用手册
附录 1 附录 2 附录 3 附录 4 附录 5
测试结果报告单编辑方法---- --------- --------- --------- --------- --( 33) 自动循环进样系统注意事项--- -------- --------- --------- --------- --( 3 4) 分常用粉体密度表--- ------ --------- --------- --------- --------- --( 34) 不同材料的样品所适用的沉降介质及分散剂--- ---- --------- --------- --- ( 35) 筛 目 — 微 米 对 照 表( 仅 供 参 考 )--------------------------------( 36)
到电脑中,依据 Mie 散射理论对散射光产生的电信号进行处理,就可以得到所测样品
的粒度分布结果。
1、基本指标与性能
(1) 测试范围: 0.1-460 μm。
(2) 重复性误差:〈1%(测标样时 D50 的偏差)。 (3) 测定时间:1-3 分钟/次。 (4) 样品浓度:10-60(为激光粒度仪遮光率数值,对
丹东百特科技有限公司 服务热线0415-6184440 网址:
1
BT-9300Z智能激光粒度仪分布使用手册

EVK-SM9300用户手册说明书

EVK-SM9300用户手册说明书

[EVK-SM9300]Rev. Note Author 20161107Initial Sandy 20161228 Rev01 SandySandy 20170407 Rev1.1:1.Add Wifi & Bluetooth support2.Update HDMI supportSandy 20170725Rev1.2.0r011.Update HDMI support2.Add HDMI Audio support3.Add PCIE networking card support4.Change Camera module to EXP-C5DX00See Detail in Release NoteSandy 20170818 Rev1.2.1r011.Add Logo support2.Add HDMI test methodsSee Detail in Release Note目录历史版本 (2)目录 (3)Release Note (5)1. Image Version (5)2. 功能列表 (5)3. Previous Version (7)第1章快速启动 (7)1.1 烧写镜像到SD卡 (8)1.2 从SD卡启动系统 (9)1.3 从EMMC启动系统 (10)1.4 启动LOGO (10)第2章功能测试 (12)2.1 LED测试 (12)2.2 RTC测试 (12)2.3 EEPROM测试 (13)2.3.1 EEPROM on SOM-SM9300 (13)2.3.2 EEPROM on BB-ESDSM00 (14)2.4 EMMC测试 (15)2.5 音频测试 (15)2.6 LVDS测试 (16)2.7 背光测试 (16)2.8 触摸屏测试 (16)2.9 VGA测试 (16)2.10 HDMI测试 (17)2.10.1 HDMI启动 (17)2.10.2 HDMI显示图像 (17)2.10.3 HDMI音频播放 (17)2.11 串口测试 (17)2.11.1 UART4测试 (17)2.12 RS485测试 (18)2.13 网络测试 (18)2.14 PCIE网卡测试 (18)2.15 CAN测试 (19)2.16 USB测试 (20)2.16.1 Host测试 (20)2.16.2 OTG测试 (20)2.17 SATA测试 (21)2.18 Camera测试 (21)2.19 WIFI测试 (22)2.19.1 配置WIFI (22)2.19.2 连接WIFI (22)2.19.3 WIFI Host AP功能 (23)2.20 Bluetooth测试 (23)2.20.1 初始化蓝牙模块 (23)2.20.2 测试蓝牙功能 (24)第3章系统编译 (25)3.1 配置编译环境 (25)3.2 编译UBOOT (25)3.2.1 获取uboot源码 (25)3.2.2 编译并烧写镜像到SD卡 (25)3.2.3 编译并烧写镜像到EMMC (25)3.3 Kernel (27)3.3.1 获取内核源码 (27)3.3.2 编译并烧写镜像到SD卡 (27)3.3.3 编译并烧写镜像到EMMC卡 (27)3.4 File system (27)3.4.1 烧写File system到SD卡 (27)3.4.2 烧写File system到EMMC (27)1.Image VersionEVK-SM9300-Image-SDcard-V1.2.1r01.img EVK-SM9300-Image-EMMC-V1.2.1r01.img2.功能列表Feature List EVK-SM9300On-Chip Peripherals On-Board Peripherals Detail Functions(existing)u-boot version 2015.04kernel version linux-3.14Filesystem filesystemboot configuration boot configuration NA boot from tf card & eMMC CPU imx6qDDR3 DDR3 256M DDR3/1066 *4eMMC 4G SD 4G bytes eMMC EEPROM I2C1 AT24C256W eeprom read and write SATA SATA connecter 2*SATAIntegrated RTC RTC NAPMICGPIO GPIO connecterSDIO2 SDIO2 TF CARDRMII RMII AR8305 RJ45usb_1 USB USB2514(USB*4 hub)USB OTG USB OTG USB OTGCAN_1 CAN1 ADUM1201 CAN*2CAN_2 CAN2RS485 UART0 ADM2483UART1 UART0 UARTUART2 UART1 MAX3232/Bluetooth DB9UART4 UART5 MAX3232I2C0 I2C I2CPCI-E I2C4+PCI-E PCI-E connecterSIM NA NAPush button button buttonSPI SPI1 connecterMIPI MIPI connecter external camera CSI CSI connecter external camera WIFI SDIO2 connecterLVDS LVDS connecterHDMI HDMI connecterLCD LCD CH7026B VGA connecterTouchscreen SPI1 TSC2046Audio I2S WM8904LED GPIO LEDJ-TAG J-TAG NADocumentALL_recheckcode-commitDBG_RS485DBG_PCIEDBG_audioDBG_SPI-flash3.Previous VersionThis release is compatible for EVK-SM9300 REV02 (SOM-SM9300 REV02+BB-ESDSM00 REV02) only. EVK-SM9300 REV01, SOM-SM9300 REV01 are not supported.For the detail info, refer to following table.HW version SW Version SummaryCore-board Base-boardRev 00 Rev 00 20160527 R&D Develop versionRev 01 Rev 01 Rev 01 1st release versionRev 02 Release Fix versionRev01/ Rev02 Rev 03 Mass product versionRev V1.1 Maintain versionRev 02 Rev 02 V1.2.1r01 New HW/SW version1章快速启动1.1烧写镜像到SD卡首先,你需要准备一张不小于2G的SD卡然后,你需要从https:///projects/win32diskimager/下载并安装Win32 Disk Imager选择需要烧写的镜像,EVK-SM9300-Image-SDcard-V1.2.1r01.img:点击Write烧写镜像:1.2从SD卡启动系统在PC上安装串口软件(例如SecureCRT),选择正确的端口号,波特率115200,8位数据位,1位停止位,无奇偶校验用交叉串口线把板子上的DEBUG接口(J20)和PC的串口相连把SD卡插入板上的插槽(J5)参照下表设置拨码开关用12V,2A的电源,系统启动完毕之后, 串口显示如下输入用户名和密码root登录;1.3从EMMC启动系统将EVK-SM9300-Image-EMMC-V1.2.1r01.img拷贝到U盘;参考1.2,先从SD卡启动系统,再将U盘插入USB接口(CON4):在串口终端输入:root@embest:~# ls /dev/sd*/dev/sda /dev/sda1root@embest:~# mount /dev/sda1 /mnt/root@embest:~# dd if=/mnt/EVK-SM9300-Image-EMMC-V1.2.1r01.img of=/dev/mmcblk0注意:烧写时间较长,请耐心等待…如果是第一次烧写EMMC,需要在eMMC用户分区使能boot_config。

(整理)9300安装说明.

(整理)9300安装说明.

目录1 概述 (1)2 安装前的准备工作 (2)3 扶梯护壁的安装 (3)4 扶手带的安装与调整 (9)5 内外盖板及扶手带入口保护装置的安装 (11)6 外部装饰材料的安装 (14)7 电气部分的安装与调试 (14)8 调试 (15)9 专用安装工具清单 (17)第一章概述1.1 声明自动扶梯的安装需要特殊的技能,只有经过国家许可的、具有相应的安装资格的经迅达公司授权的企业,才能实施自动扶梯的安装。

由于自动扶梯的性能在不断的改进,本说明并不能完全体现每一个经过改进的地方。

产品若有任何更改, 恕不通知。

本安装说明,只作为一般的安装步骤说明。

本说明未详尽列出所有可能导致危险的因素,在安装和调试设备时应遵循一切适用的安全规定。

1.2 自动扶梯的安装工序1. 安装前的准备工作。

2. 扶梯护壁的安装。

3. 扶手带的安装与调整。

4. 内外盖板及扶手带入口保护装置的安装。

5. 外部装饰材料的安装6. 电气部分的安装与调整。

7. 调试。

第二章安装前的准备工作2.1 安装施工所需资料安装人员应在开工前检查并熟悉安装技术资料及相关文件(如土建图、安装说明书、使用维护说明书、安全操作规程等),为扶梯安装作好充分的准备。

2.2 现场勘察1. 土建施工状况●按土建布置图对土建施工进行核查。

如果相关的尺寸及施工要求不符土建布置的规定,则应通知有关部门进行及时修正。

2. 人员设施的配合●安装人员应就人员配合、动力照明电源、独立接地、脚手架、库房准备等问题与使用单位及配合方洽谈,使现场具备开工条件。

3. 驳运起吊自动扶梯●选择合适的驳运通道,确定最佳的吊运方案。

驳运起吊扶梯时,应避免冲撞扶梯机身,并遵守安全规则。

4. 材料的清点与保管●安装材料开箱后应根据装箱单进行清点,并妥善堆放和保管。

●调整扶梯的空间位置。

5. 分段桁架的连接和中间支撑的安装如果扶梯桁架是分段的或配有中间支撑,就应采用随机配备的高强度螺栓进行连接和安装。

YDC9300老款科士达中文 说明书内容

YDC9300老款科士达中文  说明书内容
第二章 安装 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 2.1 开箱检验 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 2.2 安装程序 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 2.2.1 安装注意事项 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 2.2.2 安装步骤 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18 2.3 并机配线 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21
-1-
安全须知
一 禁止事项
1 电源内部有高压,非本公司或本公司授权的技术人员,请勿擅自打开面板或机箱盖。否则 会有触电的危险,同时失去保修权利。
2 应用于下述负载设备前,务必事先与经销商讨论其应用设置管理和维护等事项。 ■ 与病人生命有直接关联的医疗仪器。 ■ 电梯等有可能危及人身安全的设备。 ■ 类似于上述的设备。
6 液体或其他外来物体,绝对不允许进入电源机箱内。 7 万一周围起火请使用干粉灭火器,若使用液体灭火器会有触电危险。 8 电池的寿命随环境温度的升高而缩短,定期更换电池可保证UPS工作正常,且可维持足够

cisco 思科 Catalyst 9300 系列交换机 产品手册

cisco 思科 Catalyst 9300 系列交换机  产品手册

产品手册思科公开信息思科 Catalyst 9300系列交换机目录专为安全性、物联网、移动性和云打造3产品概述:特性4平台详细信息7平台优势16软件要求22许可22规格25保修45思科环境可持续性46思科服务46订购信息47 Cisco Capital 54文档历史记录55专为安全性、物联网、移动性和云打造思科® Catalyst® 9300 系列交换机是思科专为安全性、物联网、移动性和云打造的卓越可堆叠企业交换平台,是业界部署最广泛的下一代交换平台。

Catalyst 9300 系列交换机是软件定义接入 (SD-Access) 这一思科领先的企业架构的基本组件。

凭借最高 480 Gbps 的带宽,该系列交换机成为业界密度最高的堆叠带宽解决方案,具有无比灵活的上行链路架构。

Catalyst 9300 系列是首款专门针对高密度 Wi-Fi 6 和第二代 802.11ac 技术进行优化的平台,树立了网络规模的新标杆。

该系列交换机还为支持未来的技术做好了准备,凭借 x86 CPU 架构和更大的内存,它们能够承载容器并在交换机内部本地运行第三方应用和脚本。

Catalyst 9300 系列专为 Cisco StackWise®技术设计,提供灵活的部署,支持不间断转发和状态切换 (NSF/SSO),从而在可堆叠(低于 50 微秒)解决方案中实现恢复能力极强的架构。

电源架构采用 Cisco StackPower®技术,具备极高的恢复能力和效率,可提供高密度以太网供电 Plus (PoE+)、60W 思科通用以太网供电(思科 UPOE)和 90W 思科 UPOE+©端口。

该系列交换机基于思科统一接入™数据平面 (UADP) 2.0 架构,不仅可以保护您的投资,还能扩大规模并提高吞吐量。

交换机采用具有可编程性的 Cisco IOS® XE,这款现代化操作系统可提供高级安全功能和物联网 (IoT) 融合。

「中文手机说明书9300」

「中文手机说明书9300」

使用本说明书感谢您选购本手机。

本手机基于Android的高科技和高标准,为您提供高品质的移动通信和娱乐享受。

本使用说明书专门用于指导您了解手机的功能与特性。

请先阅读说明文件. 使用手机之前,请先仔细阅读全部安全注意事项和本说明书,以确保安全和正确使用。

. 本说明书中的描述基于手机的默认设定。

. 本说明书中所用的图像和屏幕截图可能与实际产品的外观不同。

. 本使用说明书中的内容可能与产品不同,也可能与服务提供商或服务商提供的软件不同。

如有变更,恕不另行通知。

. 可用功能和附加服务可能因手机、软件或服务提供商而异。

.本使用说明书的格式和资讯基于Google Android 操作系统,用户使用的操作系统可能与之有所不同。

. 应用程序及其功能可能因国家、地区或硬件规格而异。

由第三方应用程序导致的性能问题概不负责。

. 由用户编辑注册表设置而导致的性能问题或不兼容问题概不负责。

. 收发信息、上传和下载、进行自动同步或使用定位服务可能会产生其他费用。

如欲避免产生额外费用,选择合适的数据收费计划。

有关详细信息,请联系服务提供商。

. 请妥善保存本说明书以供日后参考。

指示图标在开始使用前,请先熟悉本说明书中的图标:警告—可能伤及自己或他人的情况。

小心—可能损坏手机或其他设备的情况。

注意—注释、使用提示或其他资讯。

安装配件介绍检查产品包装盒内是否有下列物品:. 手机. 电池.旅行充电器(充电器). 使用说明书.只可使用经过认可的软件。

盗版或非法软件可能会导致损坏或故障制造商对此不予保修。

. 随手机提供的物品可能不同,具体取决于您所在地区可使用的或服务提供商所提供的软件和配件。

. 可以向本地经销商购买其他配件。

. 提供的配件能为手机提供最好的支持。

. 提供的配件之外的其他配件可能与您的手机不兼容。

安装SIM或USIM卡和电池当您订购移动电话服务时,将获得一张用户识别模块(SIM)卡,其中载有您的订购详细信息,例如个人识别号码 (PIN)和可选服务。

华为S9300路由交换机产品资料说明书

华为S9300路由交换机产品资料说明书

Huawei S9300 SwitchProduct BrochuresRealize Your Potential01 Huawei S9300 Switch ProductHuawei S9300 series (S9300 for short) terabit routing switches are next-generation high-end smart switches tailored for multiservice networks. The S9300 uses Huawei's intelligent multilayer switching concept to provideAn S9300 running a system software version of V2R5C00 or later can be upgraded to an agile switch by using S9303 S9306S9312 Product OverviewProduct FeaturesAgile Switch, Enabling Networks to Be More Agile for Services• The high-speed ENP is tailored for Ethernet networks. The ENP's flexible packet processing and traffic control capabilities can meet current and future service requirements and help build a highly scalable network. The ENP has a fully programmable architecture, in which customers can define their own forwarding models, forwarding behaviors, and lookup algorithms. Microcode programmability enables new services to be provisioned within six months, without the need of replacing the hardware. In contrast, with traditional ASIC chips, new services cannot be provisioned until new hardware is developed to support the services, which may take 1 to 3 years, because ASIC chips use a fixed forwarding architecture and follow a fixed forwarding process.• By using an X1E board, the S9300 supports the unified user management function to authenticate both wired and wireless users, ensuring a consistent user experience regardless of whether they use wired or wireless access devices to connect to the network. The unified user management function supports various authentication methods, including 802.1x, MA C, and Portal authentications, and is capable of managing users based on user groups, domains, and time ranges. This function visualizes user and service management and enables the transformation from device-centric management to user-centric management.• The X1E board supports the Packet Conservation Algorithm for Internet (iPCA) function, which changes the traditional method of using simulated traffic for fault location. iPCA technology can monitor network quality for any service flow at any network node, at any time, and without extra costs. It can detect temporary service interruptions in a very short time and precisely identify faulty ports. This cutting-edge fault detection technology turns "extensive management" to "fine granular management."Innovative CSS Technology• S9300 switches can set up a clustering switch system (CSS) through cluster cards or service ports. The CSS provides industry-leading 320 Gbps inter-chassis bandwidth due to Huawei's novel approach of using the switching fabric clustering technology in CSS. Member switches can be connected through the service ports on LPUs. These service ports can be configured as stack member ports and added to a logical stack port to enable connectionthrough SFP+ optical modules and fibers, or direct connection through SFP+ stack cables. Virtualization technology improves link use efficiency and preventssingle-point failures through inter-chassis link aggregation.• The S9300 uses route hot backup technology to backup and uninterruptedly forward all data of the controland data planes at Layer 3. This technology significantly improves reliability and performance of the S9300. Theinter-chassis links in a CSS can be bundled to improve linkuse efficiency and eliminate single-point failures.• The S9300 can use common service ports as cluster ports,and member switches can be connected through opticalfibers. This increases the permitted distance between switches in the CSS.• All member switches in a CSS are managed through asingle IP address, which simplifies network device and topology management, improves network operationefficiency, and reduces maintenance costs.Carrier-Class Reliability• The S9300's key components, such as MPUs, power supplies, and fans trays, use a redundant design, and all modules are hot swappable to ensure stable network running.• The S9300 supports 3.3 ms hardware-based BFD for staticroutes and routing protocols such as RIP, OSPF, BGP, IS-IS, VRRP, PIM, and MPLS. Hardware-based BFD significantly improves network reliability.• The S9300 supports High-speed Self Recovery (HSR) technology. Using Huawei's ENP cards, the S9300 is the industry's only switch that implements end-to-end IPMPLS bearer network protection switchover within 50 ms, improving network reliability.• The S9300 supports hardware-based Ethernet OA Min compliance with IEEE 802.3ah, 802.1ag, and ITU-Y.1731. Hardware-based Ethernet OAM can collect precise network parameters, such as transmission latency andjitter, to help customers monitor network operating statusin real time and to realize fast fault detection, location,and failover.• The S9300 supports Graceful Restart (GR) technology to implement nonstop forwarding (NSF) and ensure reliableand high-speed operation of the entire network.Powerful Service Processing Capabilities• The S9300 provides high-density 10GE ports and provide 2 x100GE line card, Each S9312 chassis can provide a maximumof 480 x 10GE ports and 24 x 100GE ports, meeting the requirements of bandwidth-consuming applications, such as multimedia conferencing and data access.02• Based on a multi-service routing and switching platform, the S9300 provides wireless access, voice, video, and data services for network access, aggregation, and core layers, helping customers build a highly reliable, low-latency, and multi-service network.• The S9300 supports distributed MPLS L2/L3VPN functions including MPLS, virtual private LA N service (VPLS), hierarchical VPLS (HVPLS), and virtual leased line (VLL), to provide secure access for VPN users.• The S9300 supports comprehensive Layer 2 and Layer 3 multicast protocols, including Protocol Independent Multicast Sparse Mode (PIM SM), PIM Dense Mode (DM), PIM Source-Specific Multicast (SSM), Multicast Listener Discovery (MLD), and Internet Group Management Protocol (IGMP) snooping, to ensure high-quality HD video surveillance and video conferencing services.• The S9300 supports multi-service virtualization technology to provide value-added service (VAS) solutions for campus networks. This technology virtualizes the VAS capabilities, such as firewall (FW), antivirus engine (AVE), and application security gateway (ASG), so that the network entities, such as switches, routers, ACs, APs, and terminals, can use these virtualized capabilities without the restriction of physical locations.• The software platform where the S9300 runs supports various routing protocols (including IPv6) to meet carriers' network requirements and allows carriers to smoothly upgrade their networks to IPv6.Various Network Traffic Analysis Functions• The S9300 supports NetStream, including V5/V8/V9 versions. The NetStream features involve aggregation traffic template, real-time traffic sampling, dynamic report generation, traffic attribute analysis, and traffic exception alarms. The S9300 sends traffic statistics logs to master and backup servers simultaneously to avoid data loss. NetStream helps monitor the operating status and traffic model on the entire network. It also provides fault pre-detection, effective fault rectification, fast problem handling, and security monitoring capabilities to help customers optimize network structure and adjust service deployment.Comprehensive Security Measures• The S9300 supports MAC security (MACSec) that enables hop-by-hop secure data transmission. The S9300 can be applied to scenarios that pose high requirements on data confidentiality, such as government and finance sectors.• NGFW is a next-generation firewall card installed on an S9300. In addition to the traditional defense functions, such as identity authentication and Anti-DDoS, the NGFWsupports IPS, anti-spam, web security, and application control functions.• The S9300 provides comprehensive network admission control (NAC) solutions, involving MAC, 802.1x, and Portal authentications as well as authentication triggered by DHCP snooping. These authentication methods ensure the security of various access users, such as dumb terminals, mobile users, and users allocated dynamic IP addresses. • The S9300 supports a two-level CPU protection mechanism, which supports 1K CPU hardware queues and separates the data plane from the control plane, to help minimize threats of DoS attacks, unauthorized access, and control plane overloading. With this mechanism, the S9300 offers an industry-leading integrated security solution.Comprehensive IPv6 Solution• The S9300 software and hardware platforms support IPv6. The Ministry of Industry and Information Technology (MIIT) has certified the S9300 as IPv6 network-access compliant and has awarded IPv6 Ready Logo Phase 2 certification.• The S9300 supports IPv6 routing protocols such as RIPng, OSPFv3, IS-ISv6, as well as IPv6 static routes, and supports BGP4+, MLD v1/v2, MLD snooping, PIM-SM/DMv6, and PIM-SSMv6.• The S9300 supports various IPv4-to-IPv6 technologies to ensure seamless network migration. The technologies include IPv6 manual tunnel, 6to4 tunnel, Intra-site Automatic Tunnel Addressing Protocol (ISATAP) tunnel, Generic Routing Encapsulation (GRE) tunnel, and IPv4-compatible automatic tunnel.Innovative Energy Saving Design• The S9300 uses a rotating ventilation channel to improve heat dissipation efficiency and a variable-current chip to dynamically adjust power according to traffic volume. These technologies reduce power consumption of the entire chassis by 11%. The S9300 supports port sleeping. Idle ports enter the sleeping state to reduce power consumption.• The S9300 supports intelligent fan-speed adjustment, in which fans are grouped into multiple zones and fan speed in each zone is adjusted individually based on service loads. This technology lowers power consumption, reduces noise, and extends the service life of fans.• The S9300 supports Energy Efficient Ethernet (EEE) in compliance with IEEE 802.3az. Transceivers on line cards can quickly transition to the lower power idle state to reduce power consumption when no traffic is being transmitted.03Product Specifications040506ApplicationsApplications in Carriers' MANsApplications in Large-Scale Data CentersThe S9300 provides carrier-class reliability, security, and manageability. By converging DSLAM, LAN, and enterprise access services, the S9300 provides large-capacity switching and high-density 10G interfaces. At the convergence layer, the interface rate can be smoothly upgraded from 10GE to 40GE/100GE, meeting the increasing bandwidth requirements of ISP networks. The S9300 supports features such as RRPP , Ethernet OAM, VRRP , and MPLS L2/L3VPN, and satisfies the requirements for IPTV, high speed Internet (HSI), and enterprise leased lines.The S9300 switches function as high-density 10G core and aggregation nodes in large-scale data centers, helping enterprises build highly reliable, non-blocking, and virtualized data center networks. The S9300 switches use various technologies, including IP FRR, hardware-level BFD, NSF, VRRP , and E-Trunk, to ensure uninterrupted services. In addition, the S9300 switches support the CSS function to improve network IT efficiency and reduce network maintenance costs.For more information, visit / or contact your local Huawei sales office.Web & Email Application Application DatabaseS2300Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.Trademark Notice, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.Other trademarks, product, service and company names mentioned are the property of their respective owners.General DisclaimerThe information in this document may contain predictive statements including,without limitation, statements regarding the future financial and operating results,future product portfolio, new technology, etc. There are a number of factors thatcould cause actual results and developments to differ materially from thoseexpressed or implied in the predictive statements. Therefore, such information isprovided for reference purpose only and constitutes neither an offer nor anacceptance. Huawei may change the information at any time without notice.。

(整理)9300安装说明.

(整理)9300安装说明.

目录1 概述 (1)2 安装前的准备工作 (2)3 扶梯护壁的安装 (3)4 扶手带的安装与调整 (9)5 内外盖板及扶手带入口保护装置的安装 (11)6 外部装饰材料的安装 (14)7 电气部分的安装与调试 (14)8 调试 (15)9 专用安装工具清单 (17)第一章概述1.1 声明自动扶梯的安装需要特殊的技能,只有经过国家许可的、具有相应的安装资格的经迅达公司授权的企业,才能实施自动扶梯的安装。

由于自动扶梯的性能在不断的改进,本说明并不能完全体现每一个经过改进的地方。

产品若有任何更改, 恕不通知。

本安装说明,只作为一般的安装步骤说明。

本说明未详尽列出所有可能导致危险的因素,在安装和调试设备时应遵循一切适用的安全规定。

1.2 自动扶梯的安装工序1. 安装前的准备工作。

2. 扶梯护壁的安装。

3. 扶手带的安装与调整。

4. 内外盖板及扶手带入口保护装置的安装。

5. 外部装饰材料的安装6. 电气部分的安装与调整。

7. 调试。

第二章安装前的准备工作2.1 安装施工所需资料安装人员应在开工前检查并熟悉安装技术资料及相关文件(如土建图、安装说明书、使用维护说明书、安全操作规程等),为扶梯安装作好充分的准备。

2.2 现场勘察1. 土建施工状况●按土建布置图对土建施工进行核查。

如果相关的尺寸及施工要求不符土建布置的规定,则应通知有关部门进行及时修正。

2. 人员设施的配合●安装人员应就人员配合、动力照明电源、独立接地、脚手架、库房准备等问题与使用单位及配合方洽谈,使现场具备开工条件。

3. 驳运起吊自动扶梯●选择合适的驳运通道,确定最佳的吊运方案。

驳运起吊扶梯时,应避免冲撞扶梯机身,并遵守安全规则。

4. 材料的清点与保管●安装材料开箱后应根据装箱单进行清点,并妥善堆放和保管。

●调整扶梯的空间位置。

5. 分段桁架的连接和中间支撑的安装如果扶梯桁架是分段的或配有中间支撑,就应采用随机配备的高强度螺栓进行连接和安装。

BT-9300S用户手册

BT-9300S用户手册

服务热线0415-6184440
网址:wLeabharlann
BT-9300S激光粒度分布仪使用手册
2、基本特点: (1) 仪器采用先进的成型工艺,使仪器的结构紧凑合理,外形美观大方,使用维护 方便;采用有效的抗干扰技术,使仪器的电气稳定性更好,故障率更低。 (2) 具有自动循环分散系统和微量样品池两种进样方式,这样 BT-9300S 激光粒度 分布仪就适用于水介质或非水介质(比如乙醇、苯类等有机溶剂) ,两种装置 的更换方便快捷。用户可以根据样品的需要选择配有其中的一种进样方式。 (3) 数据处理采用 Mie 散射理论与 Fraunhoffer 衍射理论两种方法, 每一种方法中 包含“通用” 、 “超细与窄分布” 、 “R-R 分布” 、 “单分散”和“多峰”五种分布 形态。这样就可以适应不同行业、不同领域、不同用户的需要。 (4) 仪器内部设有三维自动对焦系统,该系统在电脑控制下将自动寻找透镜的焦 点,用于进行自动背景校准;仪器配备自动循环分散送样系统,使样品制备更 加简便。这些措施都提高了仪器的测量精度。 (5) 独特设计的具有 76 个接收器的光电探测器阵列(BT-2003 激光粒度仪更有多 达 88 个光电探测器) ,使仪器具有的很高的分辨率。 (6) 测试软件是标准的 Windows 界面,界面友好、操作简单。软件系统不仅具有 多次测试、结果平均、显示、打印、存储、查询、比较、合并、编辑、删除、 调整、帮助等常用功能,还具有自动背景校准、多语言选择、多仪器选择、仪 器标定等特殊功能,更重要的是采用了最新的数据处理方法和反演算法,使仪 器准确性与重复性达到国外同类产品先进水平。 。 (7) 测试结果报告单有 7 种中文格式、7 种英文格式,在每一种格式中又有升序、 降序、区间、单列以及百分数等形式,因此百特激光粒度仪具有极其丰富的报 告单格式和所有常用的内容。 3、应用领域 (1) 各种非金属粉的生产、应用与研究领域:如碳酸钙、滑石粉、高岭土、硅酸锆、 硅灰石、石墨、粉石英、电气石、云母、重晶石、石膏、膨润土、金刚石、石 英、硅藻土、长石、透闪石、粘土、石榴石、蛭石、钛白粉等。 (2) 各种金属粉的生产、应用与研究领域:如铝粉、铁粉、镁粉、钼粉、铜粉、锌 粉以及其它稀有金属粉和各种合金粉等。 (3) 其它:如医药、农药、磨料、食品、水泥、陶瓷、土壤、颜料、科研教学、石 油勘探、地质分析、河流泥沙、电子材料、化工材料、军工材料、电池材料等。
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
2 安装单板
产品形态 S9303 S9306 S9312 S9303E S9306E
S93012E
SRU 不支持
支持 支持 不支持 支持 支持
FSU 不支持 支持 支持 不支持 不支持 不支持
CMU 不支持 支持 支持 不支持 支持 支持
MCU 支持 不支持 不支持 支持 不支持 不支持
LPU 支持 支持 支持 支持 支持 支持
S9300&9300E T比特路由交换机
快速安装指南
文档版本:19 发布日期:2013-04-20
华HU为AW技E术I T有EC限HN公O司LOGIES CO., LTD.
修订记录
修订记录累积了每次文档更新的说明。最新版本的文档包含以前所有文档版本的更新内容。
文档版本 19(2013-04-20) 相对于版本 18(2012-12-08)的变化如下: 修改: 调节挂耳的内容。 增加: 业务口集群安装的内容。
文档版本 15(2012-03-15) 相对于版本 14(2011-07-15)的变化如下: 增加: S9306E设备的安装方法。
文档版本 14(2011-07-15) 相对于版本 13(2011-05-20)的变化如下: 修改: 集群线缆使用的盘线盒外观图。 增加: 安装时钟扣板的方法。
1
注意事项
文档版本 18(2012-12-08) 相对于版本 17(2012-08-15)的变化如下: 修改: S9300&S9300E手册合一写作。
文档版本 17(2012-08-15) 相对于版本 16(2012-05-23)的变化如下: 增加: 拔纤钳的描述和光纤出线高度的图示说明。
文档版本 16(2012-05-23) 相对于版本 15(2012-03-15)的变化如下: 增加: 在安装集群线缆处增加光纤集群安装。
粘贴标签/标识牌 • 标签/标识牌默认粘贴位置在距离连接器20mm处。 • 当电缆垂直布放时标签/标识牌朝向右。 • 当电缆水平布放时标签/标识牌朝向下。
• 电源线在安装完成之前禁止与供电设备相连接。 • 建议电源线和信号线缆分开走线。 • 一台设备上不能混合使用直流电源和交流电源。 • 一柜多框的情况下,机框之间距离不得小于1U(1U=44.45mm)。
4 安装FSU板(可选)
FSU板是SRU板的子卡,插在SRU板 上。
8
安装单板 5 安装CMU板
6 安安装装LMPCUU板板
S9303&S9303E的MCU板插在4和5号槽位。
7 安装LPU板
1、S9303&S9303E有3个LPU板槽位,编号为1~3。S9306&S9306E有6个LPU板槽位,编号为1~6。 S9312&S9312E有12个LPU板槽位,编号为1~12。 2、S9300&S9300E机框安装LPU板的方法是一样的,这里的图形以S9306的机框来举例说明。
7
安装单板 1 安装前准备
1、S9300&S9300E系列机框的槽位信息请参见《S9300&S9300E T 比特路由交换机 硬件描述》中的“设 备结构”中的槽位分布示意图。 2、安装单板前需要将待安装槽位的假面板拆卸下来。如果单板已经插在机框上,请重新插拔设备上的单 板,并保证单板安装正确。 3、请佩戴防静电手腕或防静电手套进行安装单板的操作,禁止裸手操作。 4、在安装单板过程中,务必缓慢、平稳地沿着机框插槽的导轨插入,避免上下晃动而导致碰到单板上的 元器件,以免损坏单板。安装完成后,务必确认单板已经完全插入机框。
M10 M11
M9
将3个短螺柱安装在MCU板上M9、M10、M11位置,拧紧。
c 固定时钟扣板
1、时钟扣板的安装朝向为:带元器件的那一面朝下。 2、将时钟扣板的3个固定孔跟SRU板上的3个长螺柱(或者是 MCU板上的3个短螺柱)对齐,采用螺钉2固定,拧紧。
10
安装保护地线 1 线缆准备
机柜接地线
设备接地线
a 安装分线齿
将定位销钉套上葫芦孔,固定一个螺钉。
葫芦孔
c 调节挂耳位置
为了适应不同的机柜要求,S9300&S9300E 可以调整挂耳安装的前后位置。 S9300&S9300E调整挂耳的方式和过程一样, 这里的图形以S9306举例说明。 • 当使用华为机柜时,方孔条到前门距离 为95mm。 图中数据标示:B=585mm,A=88mm
b 安装前检查
序号 检查项
序号 检查项
1
确认机房提供的配置条件:
6
• 直流电压:
- 48V:-38.4V DC ~-57.6V DC(额定电压:-48V DC)
- 60V:-48V DC ~-72V DC(额定电压:-60V DC)
• 交流电压:
S9303&S9303E:90V AC~290V AC,47Hz~ 63Hz (额定电压:110V AC/220V AC,50/60Hz)
2
安装准备 1 安装工具
记号笔 活动扳手
防静电腕带 网线测试仪
铅直测定器
十字螺丝刀 裁纸刀 网线钳 万用表
一字螺丝刀 浮动螺母安装条
剥线钳 卷尺
防静电手套
梯子
3
安装准备 2 安装环境
a 机柜选择
S9300&S9300E系列产品可以安装在19英寸标准机柜中。 • 使用华为机柜
机柜 N66E N68E
S9306&S9306E:90V AC~290V AC,47Hz~ 63Hz (额定电压:110V AC/220V AC,50/60Hz)
S9312&S9312E:175V AC~290V AC,47Hz~ 63Hz (额定电压:220V AC,50/60Hz)
配电柜至少有2个空余端口(空开小于40A,大于 20A)。
M8/M32 M11
1、将3个长螺柱放置在SRU板上的螺孔位置: •SRUA板的螺孔位号是: M8、M10、M11 •SRUB板的螺孔位号是: M32、M10、M11 •LE2D2SRUDC00板的螺孔位号是: M8、M10、M11
2、从SRU板的背面采用螺钉1将3个长螺柱固定。
安装短螺柱(S9303&S9303E)
检查用于迅速定位机箱在机柜中的安装位置的 安装模板是否存在。
2
确认ODF已安装完毕,并且有足够的空余端口。
7
检查是否有用于搬移设备的2个活动抬手
3
确认机房接地排已安装完毕。
( S9303&S9303E除外 )。
4
检查浮动螺母(若干)是否齐全。
5
检查机柜是否有滑道和浮动螺母。
4
安装机箱 1 机箱安装准备
分线齿
风扇
机箱
• 当不使用华为机柜时,如果机柜深度大于等
于800mm ,需要调整挂耳安装位置。分线齿
到挂耳安装面的距离为68mm时,需保证机箱
出线面到前门距离大于等于110mm。
图中数据标示: B=585mm,A=68mm
侧面图
挂耳安装孔位 置
分线齿
风扇
机箱
图中数据标示: B=585mm,A=108mm
b 拆卸活动抬手
S9303&S9303E带板发货,没有活动抬手,一人即 可搬运机箱入机柜。
c 固定机箱
•当机箱放到滑道上时需拆掉把手,再将机箱推入机柜。 •抬手使用完毕,需挂回到设备背面的指定位置。 •如果是单开门机柜,抬手使用完毕后,请妥善保管。
d 安装后注意事项
1、请将随设备发货的拔纤钳固定放置在机柜或机架中,后续操作高密度网口板上的网线、光纤时能方便 取用到。 2、请勿将设备的进风口(左侧)和出风口(后侧)堵上,至少预留70mm~90mm安装空间,否则会影响 设备的正常散热。
3 安装SRU板
CKM 支持 支持 支持 支持 支持 支持
1、S9306&S9306E的SRU板插在7号和8号槽位,S9312&S9312E的SRU板插在13号和14号槽位。 2、S9300&S9300E系列机框安装SRU板的方法是一样的,只是S9300E的主控板采用新式的拉手条, 这里的图形以S9306来举例说明。
6
二安级装步骤机标箱题采用16PT黑体加粗 (中文黑体,英文Arial) 3 安安)安装装装机机箱箱箱到到到机机机柜柜柜
a 搬运机箱入机柜
•搬运S9303&S9303E的机箱时,禁止以机箱上檐的 铁皮作为受力点,否则会影响机箱变形。 •S9306&S9306E、S9312&S9312E的机箱安装固定 到机柜中之后再安装单板,目的是在抬机箱时,减 轻机箱的重量,避免因为机箱过于沉重而增加抬机 箱的危险性。 •抬手进入卡槽后,需要沿机箱外壁向上提紧一下。 •在抬机箱之前,必须确认抬手已经上拉扣紧,确认 扣紧后方可用力抬起机箱。
• S9303&S9303E无抬手。 • 抬手进入卡槽后,需要沿机箱外壁向上提紧一下。
5
侧面图
风扇
挂耳安装孔位 置
分线齿 机箱
二安级装步骤机标箱题采用16PT黑体加粗 (中文黑体,英文Arial) 2 定) 位S9306在机柜中的安装位置
a 裁剪安装模板
安装S9303&S9303E和S9306&S9306E的机框时, 分别沿着安装模板标记好的剪裁线进行裁剪。安装 S9312&S9312E的机框时,不需要裁剪安装模板。 这里的图形以S9306举例说明。
2 机柜接地
机柜接地线另一端接到机房的接地排上。
3 设备接地
机箱接地线固定在机柜后部方孔条内侧的接地点上。
设备接地点机柜接地点Fra bibliotekS9306
设备接地点
•S9303在机箱后部左下方有一个接地端子。S9306和 S9312在机箱前部右下方有一个接地端子。 •S9300E在机箱后部左下方有一个双OT接地端子。
相关文档
最新文档