Title: ULTRASONIC EXAMINATION PROCEDURE 1.适用范围 1. SCOPE OF APPLICATION This procedure is compiled in accordance with the requirements of 1.1 本规程按 ASME 第 V 卷和第 Ⅷ第 1 分册要求编制。 ASME Code Section V and Section Ⅷ Division 1. 1.2 In accordance with this procedure a pulse-echo type of ultrasonic 1.2 按规程对规范产品的检查用脉 instrument shall be used for Code product examination. Single probe, 冲反射式超声波探伤仪。以单斜 angle beam scanning shall be the principal method, if necessary, straight 探 头扫查为主要方法,必要时可 辅以直探头扫查。 beam scanning may also be used. 1.3 This procedure is applicable for ultrasonic examination of 1.3 本规程适用于板厚≥8mm 钢 butt-welded, full penetrated joint in wrought ( rolled, drawn, forged or 制压力 容器全焊透对接焊缝的 extruded) material with thickness equal to or greater than 5/16in.(8mm) 超声检查(包括焊缝金属和热影响 detecting, locating and evaluating the reflectors from the weld metal, 区)。 1.4 本规程不适用于单面焊部分焊 heat affected zone and base metal adjacent the weld. 1.4 Ultrasonic examination of single side welded partial penetrated welds 透焊缝的检查,也不适用于奥氏 and austenitic steel welds are not considered to be within the scope of 体钢焊缝的的检查。 1.5 除非其他程序经批准、有关具 this procedure. 1.5 Unless other procedure has been approved and accepted that may 体要求经认可,UT 有关方法、评 specify particular requirements, ultrasonic examination relating to 定、要求应按本规程。 method, evaluation, and detailed technique and requirement shall be in 2.无损探伤人员 2.1 无损探伤人员应按本公司根据 accordance with this procedure. SNT-TC-IA(现行版)制定的“NDE 2. NDE PERSONNEL 2.1 NDE personnel shall be qualified and certified according to 人员培训、考试、资格鉴定和认 NJBST’S Written Practice QCD-011 based on SNT –TC-IA (Current 证的实施细则”进行资格鉴定和 认证。 Code Accepted Edition). 3.一般探伤要求 3. GENERAL EXAMINATION REQUIREMENTS 3.1 探测范围 3.1 Examination coverage 应通过探头在探测面的移动, The volume shall be examined by moving the search unit over the 使焊缝全体积均受超声束扫查。 examination surface so as to scan the entire examination volume .Each pass of the search unit shall overlap a minimum of 10% of the transducer 探头的扫查路径应至少重叠探头 (piezo-electric element) dimension perpendicular to the direction of the 横向宽度的 10% 3.2 探头移动速度 scan. 探伤时,探头移动速度应不大 3.2 Speed of Search Unit Movements 于 150mm/s。 The speed of search unit movement for examination shall not exceed 6 3.3 记录水平 in./sec (150mm/sec.) 凡波高超过 50% DAC 基准线而 3.3 Recording Level 未予返修的讯号均应记录在案。 All reflections from uncorrected areas having responses that exceed 50% 4.超声仪、探头和参数 of reference level shall be recorded. This record shall locate each area, 4.1 超声仪 the response level, the dimensions, the depth below the surface, and the 应使用下列脉冲反射式超声仪: classification. 4. ULTRASONIC INSTRUMENT, SEARCH UNIT AND PARAMETERS 4.1 Ultrasonic Instrument A pulse-echo type of ultrasonic instrument shall be used. The following instruments are recommended in examination. Instrument Type CTS-26 Manufactured by Shantou, China

UT通用工艺规程

UT通用工艺规程

UT通⽤⼯艺规程1 适⽤范围1.1 本规程适⽤于公司承压设备采⽤A型脉冲反射式超声仪检测⼯件缺陷的超声检测⽅法和质量分级。

1.2 本规程适⽤于⾦属材料制承压设备⽤原材料或零部件和焊接接头的超声检测,也适⽤于⾦属材料制再⽤承压设备的超声检测。

1.3 本规程规定了承压设备厚度的超声测量⽅法。

1.4 与承压设备有关的⽀撑件和结构件的超声检测,也可参照本规程。

2 依据标准TSG R0004-2009 《固定式压⼒容器安全技术监察规程》GB150-2011 《压⼒容器》NB/T47013-2015 《承压设备⽆损检测》3 术语和定义本规程引⽤设术语和定义按照NB/T47013.1中第3条款及NB/T47013.3中第3条款的界定。

4 检测⼈员4.1 超声检测检测的⼈员应满⾜NB/T47013.1的有关规定。

4.2超声检测⼈员应具有⼀定的⾦属材料、设备制造安装、焊接及热处理等⽅⾯的基本知识,应熟悉被捡⼯件的材质、⼏何尺⼨及透声性等,对检测中出现的问题能作出分析、判断和处理。

5 检测设备和器材5.1 推荐使⽤下⾯的超声仪仪器型号产地HS600 武汉中科PXUT-350C 南通友联5.2 检测仪器、探头和组合性能5.2.1检测仪器采⽤A型脉冲反射式超声检测仪,起⼯作频率按-3dB测量应⾄少包括0.5MHz-10MHz频率范围,超声仪器各性能的测试条件和指标要求应满⾜NB/T47013.3附录A的要求并提供证明⽂件,测试⽅法按GB/T27664.1的规定。

圆形晶⽚直径⼀般不应⼤于40mm,⽅形晶⽚任⼀边长⼀般不应⼤于40mm,其性能指标应符合NB/T47013.3附录的要求并提供证明⽂件,测试⽅法按GB/T27664.2的规定。

5.2.3 仪器和探头的组合性能5.2.3.1 仪器和探头的组合性能包括⽔平线性、垂直线性、组合频率、灵敏度余量、盲区(仅限直探头)和远场分辨⼒。

5.2.3.2 新购置的超声检测仪器和探头,或仪器和探头在维修或更换主要部件后及检测⼈员有怀疑时应测定仪器和探头的组合性能。

核电核级工艺管道焊缝UT自动工艺检验分析

核电核级工艺管道焊缝UT自动工艺检验分析
电源。

现场对施工 区域及设 备准备 ,对施工文件
进行编审,对现场施工先决条件进行预先检查 、 准备 ,对 “ 人 、机 、料 、法 、环 ”进行落实并
检查。
先决条件满足施工要求 ,释放施 T先决条 件点 ,承包商开展补焊工作 。

要:核级工艺管道焊缝施工结束后 ,按照役检U T 工艺检验出现可达性问题,由于设计技术条件不完
善 ,通过组织设计、检验、管理各方人员从设计文件、施工文件准备及现场实体的论证 ,组织措施得
力,现场进一步实施了有效的补焊 ( 修饰焊缝作业 ),通过再次焊缝表面打磨 ,达到 了表面相对平整状
态,满足了自动U Ⅱ 艺可达性要求,解决了焊缝采用 自动U Ⅱ 艺检验过程中出现的盲区问题。
关键词 :核级工艺管道 ;焊缝检验 ;自动U T I 艺
1 概

检查所 使用 的方法 、技术和装备类型 ,应尽可
能与在役检查所使用 的保持一致 。 核安全 1 级部件焊缝役检分类及要求 : 1 ) 容器 的承压焊缝

核 电厂施工过程中 ,要求按照A S ME 第Ⅺ卷 ( 9 8 版及至2 o o o  ̄* b )的要求进行检测 ( 即: 执行役检U T自动工艺检验要求 )。 施工中检验方法 ,必须与役检的工艺方法 与役前检查 的表面状态 、检测方法保持一致性, 这三个过程的焊缝表面状态应是保持 一致 的, 施 工后的检验应该是 为水压试验后 的役前检查 做 基础的。因此 ,施工过程 中的检验显得格外
的重 要 。
容器承压焊缝 ( B — A,B — B),检验量为
1 0 0 %;

容器接管焊缝 ( B - D),检验量为1 0 0 %;

UT探伤工艺要点

UT探伤工艺要点

UT探伤工艺要点无损检测工艺CZ—-UT无损检测工艺坡口焊缝的超声波检测上海振华港口机械(集团)股份有限公司常州基地质检部探伤室1无损检测工艺CZ—-UT坡口焊缝的超声波检测工艺1 主题内容与适用范围本标准适用于制造起重机械如集装箱岸桥和场桥、卸船机、散货机等起重机械钢结构焊缝的超声检测每种无损探伤方法均有优点和局限性各种方法对缺陷的检测几率也不会相同超声探伤(UT)方法主要用于检测被检物的内部缺陷本工艺与标准适用于指导厚度在 8mm和mm之间、包括这两个厚度在内的坡口焊缝和热影响区进行的超声检测这些工艺和标准不适用于管材与管材的T、Y或K形连接焊缝的检测母材这些工艺不打算用于母材采购的检测不过,与焊接有关的、在邻近(焊缝的)母材中出现的、按本规范条款为不合格的不连续(开裂,层状撕裂,分层等),必须报告工程师处理 2 引用标准/ 美国国家标准-钢结构焊接规范 JB - 中国机械行业标准压力容器无损检测 3 超声探伤人员资质审定只有取得专业认证机构颁发 UT-II级及II级以上资格的人员才可以独立进行超声检测、签发报告资质审定按GB进行,由书面考试和用以证明操作能力的操作考试组成,操作考试应使用生产中检验焊缝所用的专用设备和规程这一考试必须要求超声操作人员证明其具有应用本规范规定准确探测和处理检测结果的能力 4 超声设备设备要求超声仪器必须为脉冲反射式探伤仪,配用振荡频率为1~6的换能器显示必须为整流的视频扫描的A型显示水平线性检测仪器的水平必须按“ :版钢结构焊接规范”在检测所用的全声程距离内进行鉴定检测仪器要求检测仪器必须带有内部稳压装置,使得温升后当额定供电电压变化15%、或在使用电池情况下整个充电使用寿命时间内,响应变化不大于±1dB必须装一警报器或仪表,以便在电池耗尽而仪器切断之前,发出电池电压下降信号2无损检测工艺CZ—-UT检测仪器的校准检测仪器必须有校准用增益控制器,它应至少在60dB的整个范围内每档1dB或2dB间断可调衰减装置必须具有±1dB以内的精度鉴定程序必须按和“ :版钢结构焊接规范”所述显示范围仪器显示的动态范围必须做到1dB幅度的变化容易察觉并显示直射波束探头直射波束探头换能器必须有一不小于㎜²又不大mm²的工作面积换能器必须为圆形或方形换能器必须能分辨“ :版钢结构焊接规范”所述的三种反射波斜射波束探头斜射波束探头必须由换能器和一斜射楔块组成它可分列构成,也可为一个组合体频率换能器的频率必须在2~之间(包括2,)换能器尺寸换能器晶体形状必须为正方形或矩形,宽度为15~25㎜高度为15~20mm (见图)最大宽高比为:,最小宽高比为:角度探头必须在检测材料内产生一声束,其角度为70º、60º或45º中一个合适角度±2º 记号每一探头必须有清晰记号标明换能频率、额定折射角和入射点入射点定位方法如“ :版钢结构焊接规范”所述内部反射探头的最大容许内部反射必须如所述前沿距离探头的尺寸必须符合:从探头的前沿到入射点的距离严禁超过25㎜试块用对比试块进行鉴定的方法必须符合“ :版钢结构焊接规范”和图所示要求 5 对比标准标准图所示国际焊接学会()超声对比试块必须作为距离校准和灵敏度校准的标准如果检测仪/探头组合的对比灵敏度调节到试块的等量值,则其他便携式试块也可应用禁止使用的反射体使用“端角”反射体来校准是禁止的分辨力要求探头与检测仪的组合必须分辨出RC分辨力对比试块上的三个孔,如图所示探头位3无损检测工艺CZ—-UT置见“ :版钢结构焊接规范”规定分辨力必须根据仪器控制处于正常试验状态下,以及孔的反射指示在萤光屏中等高度进行估算分辨能力必须至少能区分来自三个孔的指示峰值这RC分辨力对比试块不是用来进行校准的每一仪器探头(底板和换能器)的组合必须在其初次使用前就要进行检验每一探头和UT装置一经组合就必须进行校验如果保存的文件记录下述项目,则这一校验无需再次进行: (1)UT机器的制造型号和系列号(2)校验的制造商类型尺寸角度和系列号 (3)校验日期和技术员姓名注:1 对比或校准时有关各表面之间的尺寸允许误差必须在标示值±㎜的范围内2 接受并反射声波所有表面的最大粗糙度必须为3 所有材料必须为 A36钢材或声学上等效的材料4 所有孔的内壁必须光滑,且必须对材料表面钻成90º5 所有刻度线与标记必须在材料表面上加工成凹槽,以使标定线持久耐用6 其他稍有不同尺寸或校准槽的校准块经认可也可使用7 上述所注各条适用于图和 6 设备鉴定水平线性在仪器每使用40小时后,必须对检测仪器需用的每一距离范围的水平线性重作鉴定鉴定方法必须按“ :版钢结构焊接规范”进行(见附录X,备用方法) 增益控制仪器的增益(衰减器)控制必须满足的要求,并必须每隔两个月按“ :版钢结构焊接规范”的要求校准一次如可证实至少等效于要求,则选用的方法可用作校准的增益控制(衰减器)的鉴定内部反射仪器最多使用40小时,就必须对每一探头的最大内部反射进行校验斜射波束探头校准每一个斜射波束探头必须在每使用8小时后用认可的校准块进行检验,以确定接触面是否平整,声波入射点是否正确,以及波束角度是否在规定的±2°的公差范围内不符合这些要求的探头必须予以修正或更换4无损检测工艺CZ—-UT7 检测时的校准衰减控制状态所有的校准与检测必须在关闭衰减(限制或抑制)控制状态下进行衰减(限制或抑制)控制的使用可能改变仪器的波幅线性和导致检测结果无效技术灵敏度和水平扫描(距离)的校准必须由超声波检测人员就要在对每一焊缝检测之前并在检测部位进行重新校准因检测人员变换,或仪器电路有下述任何一种形式的干扰,都必须重新校准: (1) 更换换能器; (2) 更换电池; (3) 更换电输出端; (4) 更换同轴电缆; (5) 电源中断(故障) 母材的直射波束检测母材直射波束检测的校准必须将探头置于母材的A面并按下述要求进行:扫描线必须将距离校准的水平扫描线调节到显示至少等于两倍板厚的量值灵敏度必须在无缺陷指示部位调节灵敏度,以使从钢板远边的第一底面回波达到全屏高度的50%~75%斜射波束检测校准斜射波束检测校准必须按如下要求进行水平扫描线必须按规定用试块或代用试块进行调节,使其显示实际的声程距离距离校准必须采用显屏上㎜刻度或㎜刻度中较为适当的一种然而,如果这种设定中任何一种由于接头的轮廓形状或厚度妨碍了对焊缝的充分检验,则距离校准必须根据需要,使用或㎜的刻度探头位置如“ :版钢结构焊接规范”所述注:所有萤光屏指示的水平位置只取轨迹线左侧起点水平基线的位置零对比基准用于伤评定(超声波检测报告的“b”项,见附录D的表格)零对比基准灵敏度,是由调节探伤仪的校准的增益控制(衰减器)来达到,调节应符合4的要求,使得最大水平轨迹偏移得到显示,符合“ :版钢结构焊接规范”的要求 8 检测工艺5无损检测工艺CZ—-UT“X”轴必须将伤定位用的“X”轴标记于焊件检测面上,方向与焊缝轴线平行其与焊缝轴线的垂直距离取决于详图的尺寸,且通常落在对接接头焊缝的中心线上;而对T形和角接接头焊缝而言,“X”轴总是落在这些焊缝的连接构件的靠近的面上(C面的相对面) “Y”轴“Y”轴连同焊缝标记号必须清晰地标注在经受超声波检测的焊缝旁的母材上这种标注的目的在于: (1)焊缝标记; (2)A面标记;(3)距离测量和离开“X”轴的方向(+或-) (4)从焊缝的端部或边缘的定位测量清洁处理所有探头接触的表面必须无焊接飞溅、污物、脂类、油类(用作耦合剂的油除外)、油漆和松散氧化皮,且必须有一容许紧密耦合形耦合剂在探头和待检测材料之间必须使用耦合剂耦合剂必须是甘油或具有适当稠度的纤维素胶与水的混合物如需要可以加增湿剂在校准块上可用轻机油作耦合剂检测范围检测焊缝时,超声波必须扫经母材,必须对整个母材进行有无层状缺陷反射的检验,检验用直射波束探头,它需符合的要求进行,校准按的要求进行如在任何区域发现底面回波消失,或者在某一位置有一等于或大于原底面回波高度的指示,且其影响正常的焊缝扫查过程,则必须确定其尺寸、部位和离A面的深度,并记录在超声波检测报告上,同时,必须使用另一种焊缝扫查方法进行检测反射体尺寸反射体尺寸的评估方法必须按“ :版钢结构焊接规范”进行不可达性如果按照表的要求进行检测、而由于如所述有层状缺陷、部分焊缝不可达时,为得到全部焊缝的检测结果,必须使用下述一种或几种选用方法进行检测: (1) 必须将焊缝表面打磨平齐; (2) 必须从A面和B面进行检测; (3) 必须使用其他探头角度6无损检测工艺CZ—-UT焊缝检测必须使用符合要求的斜射波束探头、按要求校准的仪器、使用表所示的角度检测焊缝随后的校准以及检测过程中,唯一允许进行的仪器调节是使用校准的增益控制(衰减器)进行灵敏度调节衰减(抑制或限幅)控制必须关闭按表或进行焊缝扫查时,灵敏度必须比基准水平有所提高扫查检测角度和扫查方法必须符合表所示要求对接接头所有对接焊缝必须从焊缝轴线的两侧检测角接接头和T形接头必须基本上仅从焊缝轴线的一侧检测所有焊缝的检测必须使用适当的扫查方式,或在必要时使用图所示的方式,纵向和横向的伤都要探测无论什么地方的实际情况如何,最低限度要有意做到:检测焊缝的声波在两相交方向上通过所有受检焊缝与热影响区的整个体积表检测角度工艺卡材料厚度焊缝类型对接8 ~≤35 1>38 ~≤45 1F>45 ~≤60 1G或 4 4F>60 ~≤90 1G或5 5F>90 ~≤ 6 或 7 7F>~≤ 8 或10F>~≤ 9 或11F>~≤ 12或13F>~≤ 12FT型 1 0 1F或XF F或XFF或XF F或XFF或XF F或XFF10 F11 F13 F--或或或或XF XF XF XF F或F或9或F或13或F或--角接1 0 1 1G或41G或56或7XF 10 XF 11 XF 14 XF7无损检测工艺CZ—-UT注:1 除本表有现规定外,所有检验必须从A面并用一次波法进行2 对于带有衬垫(合同不要求除去)的单面坡口接头焊缝的根部区域,只要可能,就必须用一次8无损检测工艺CZ—-UT波法并在A面上进行检测,A面即为衬垫所在面的对面(为了彻底扫查焊缝根部,也许有必要打磨焊缝面或从另外的焊缝面进行检测)3 只有为了符合本表的规定、或当必需检测表面未经打磨的不可达焊缝、或因焊件其他部分的干扰、或为满足的要求时,才必须用二次或三次波法进行检测4 只有因厚度或几何形之故而妨碍了用一次波法或二次波法对全部的焊缝区域和热影响区进行扫查时,才必须使用最大的三次波法5 关于周期荷载结构中的受拉焊缝,其厚度的顶部1/4必须从B面向A面用一次波法进行检测,厚度的底部1/4必须用一次波法从A面向B面检测也就是说,厚度顶部的1/4既可以从A面用二次波法,也可从B面用一次波法进行检测,由承包商自行选择,合同文本另有规定除外6 采用1G,68,91214,或15的方式之前,指定的焊缝表面必须打磨平齐两连接构件的A面必须处于同一平面符号:X -从“C”面检验 G -焊缝打磨平齐 O -无要求A面–材料上的扫查开始面(T形和用接接头见上图) B面–A面的对面(同一块板上) C面–在T型或角接接头所连接构件焊缝的相对面* -只有从表中第一栏中选取一项基本方法作搜索扫查、发现在焊缝金属和母材界面处有不连续性的基准高度指示时,才作此项检测 ** -用mm或mm屏幕距离校准P -只有对材料厚度的中间一半处的不连续性作进一步评估时才必须用这种发-收方式,此时只可使用相同技术规定格的45º或70º的换能器,且均面向焊缝(为控制定位,换能器必须置于夹具中-见图)发-收方式的常规波幅校准只对一个探头进行当接通双探头作发-收检验时,应保证这一校准并不作为仪器参数而变化F -必须选用70º,60º或45º换能器之一种对焊缝金属-母材界面指示作一步评估-以声程最接近垂直于有疑问的熔合面为准进行选用9无损检测工艺CZ—-UT表的工艺卡中编号说明焊缝厚度区域1 2 3 4 5 6 7 8 9 10 11 12 13 14 15顶部1/4 70º 60º 45º 60º 45º 70ºG A 60º B 70ºG A 70ºG A 60º B 45º B 70ºG A 45º B 70ºG A 70ºG A中部1/2 70º 60º 45º 70º 70º 70º 70º 60º 60º 60º 70º** 45º 45º 45º 70ºA B底部1/4 70º 60º 45º 70º 70º 60º 60º 60º 45º 60º 45º 70ºG B 45º 45º 70ºG B 最大指示当在萤光屏上出现不连续性指示时,必须对来自不连续性的可达最大指示进行调节,使得显示器上产生水平对比基准轨迹的偏离这一调节必须用校准的增益控制进行,并且仪器的分贝值读数必须作为检测报告中的“指示基准a”,用来计算“指示额定值d”衰减系数检测报告上的“衰减系数C”可由声程距离减去25mm所得差值乘以余项2得出这一系数必须化整到最接近的整数dB值根据四舍五入的办法,必须将小于1/2dB 的小数值舍去而成为较低的整数dB值,等于或大于1/2dB的小数值进位而成为较高的dB整数值指示额定值在UT报告中的“指示额定值d”表示衰减经修正后指示值与基准之间的分贝值的代数差,表达如:仪器为dB增益状态: a-b-c=d(dB)仪器为dB衰减状态: b-a-c=d(dB)不连续性的长度不连续性的长度必须按“ :版钢结构焊接规范”规定的方法决定合格与拒收的基准每一焊缝不连续性合格与否必须依其指示额定值与长度而定,如系静荷载结构则用“ :版钢结构焊接规范”表,如系周期荷载结构则用表除了在合同文本中被指定为“临界断裂”的焊缝、其合格的额定值在6dB以内、最小的不合格的额定值必须记录在检测报告上以外,仅需在检测报告上记录不合格的不连续性不合格部位的标记每个不合格的不连续性都必须用标记在焊缝上标明,直接在不连续性上面标出其全长它距离表面的深度和指示额定值必须注明在附近的母材上返修由超声波检测发现的不合格焊缝必须使用“ :版钢结构焊接规范”所容许的方法返修返修过的区域必须经超声波重新检测并将结果记入原报告,或另附报告再检测报告返修后重新检测的焊缝区域的评价必须在报告表格上另列新的一行如使用原报告表格,则必有须在原报告中项目序号前冠以R1R2……Rn如另附报告序号前冠以R 9 合格与拒收的基准11无损检测工艺CZ—-UT不连续性严重等级如表表超声检测合格——拒收标准不连续性5/16[8]~ >3/4[20]~≤3/4[20] ≤1-1/2[38] 严重等级 A级 B级70ْ ْ焊缝厚度 [mm]和探头角度 >1-1/2[38]~ ≤2-1/2[65]>2-1/2[65]~ ≤4[]>4[]~ ≤8[]70ْ≤+8 +970ْ 60ْ 45ْ 70ْ 60ْ 45ْ 70ْ 60ْ 45ْ≤+4 ≤+7 ≤+9 ≤+1 ≤+4 ≤+6 ≤-2 ≤+1 ≤+3 +5 +6 +7 +8+8 +9+10 +11+2 +3 +4 +5+5 +6 +7 +8+7 +8 +9 +10-1 0 +1 +2+2 +3 +4 +5+4 +5 +6 +7≤+10 +11C级 D级综合注释:+12 ≥+13+10 ≥+11+10 +12 +11 +13≥+9 ≥+12 ≥+14 ≥+6 ≥+9 ≥+11 ≥+3 ≥+6 ≥+8B级和C级不连续性必须至少隔开2L,但下述情况除外:当两个或更多个此类不连续性不是隔开至少2L,而是这些不连续性的联合长度与它们之间相隔距离的总和等于或小于B级或C级规定的不连续性最大容许长度时,则这种不连续性必须被视为单个的合格不连续性B级和C级不连续性距离承受主要拉应力的焊缝端部的长度严禁小于2L如果接头完全熔透的双面坡口焊缝在图纸上被注明为“受拉焊缝”时,则该双面坡口焊缝钝边区域中以“扫查水平”检测出的不连续性,必须要用比所述高出4dB灵敏度的额定指示值进行判断如果这一接头焊缝系背部清根至完好金属以清除钝边并且用MT证实钝边已被清除,则严禁应用本要求对移动探头而留在屏上的指示,则可能。

欧标EN超声波UT检测工艺

欧标EN超声波UT检测工艺

1.概述本工艺是针对钢结构制作要求,根据BSEN标准规定的相应技术文件而编制。

1.1编制依据及执行标准a.《钢结构用技术要求》(EN1090-2)b.《焊接接头超声波检测》(BSEN1714)c.《焊接接头的超声波检测——验收等级》(EN1712)1.2人员要求无损探伤人员应持有II级或II级以上资格证书,在工作上应具备认真踏实、实事求是的工作作风,技术上满足探伤的各项要求。

1.3.探伤流程1.3.1由专人验收探伤委托单,并进行登记。

1.3.2根据委托内容、委派探伤人员实施探伤。

1.3.3探伤人员进行探伤后,做好原始记录。

1.3.4及时开出探伤报告,各有关人员签证后提交。

1.3.5对不合格的焊缝应尽早开出返修通知单。

1.3.6对返修构件的探伤、扩探按重新检测程序进行。

3超声波检测工艺规程3.1范围本规程适用于大于或等于8mm的全焊透钢焊缝的超声波探伤。

3.2探伤人员3.2.1人员应持有符合EN473/ISO9712机构颁发的II级或II级以上资格证书3.2.2操作者应了解工件的材质、坡口形式、焊接工艺、缺陷可能出现位置等资料。

3.3探测面准备探测面应无焊接飞溅、锈蚀、油垢或其它影响探头平滑移动和耦合的异物,若有深坑应补焊,必要时应使用砂轮打磨或其它方法修整。

测试表面的不平整度应确保焊缝表面与探头表面间隙不超过0.5mm。

3.4探测时机除有特殊规定外,所有的焊缝均在焊后24小时且外观检验合格后进行探测。

第1页共6页3.5 耦合剂与耦合补偿3.5.1 本工艺推荐的耦合剂为CMC 。

3.5.2 本工艺规定的耦合补偿为4dB 。

3.6 探头选择、扫查部位、扫查次数要求 检测等级为C 级。

3.6.1 对接接头通常探头在焊缝单面双侧扫查,纵向缺陷扫查区域及检测区见图1,探头角度、扫查方向及扫查次数见表1。

图1:检测区域及扫查区域示意图注意:通过从接头的上下表面扫查可以获得等同于测试区域的覆盖,扫查区域可以减小表1:对接接头(板材)探头角度、板厚、扫查次数对照表母材厚度纵向显示横向显示角度斜探头 位置 直探头位 置 斜探头扫 查区宽度 扫查数 量 角度 探头位置 扫描 数量 8WT 〈15 70。

UT焊缝工艺

UT焊缝工艺

压力容器焊缝超声波检测工艺规程1 适用范围1.1 本工艺规程适用于母材厚度8~120mm锅炉、钢制压力容器、压力管道及特种设备对接缝的超声检测。

1.2 本工艺不适用于弯头与直管、带颈法兰与直管、回弯头与直管以接焊缝的超声波探伤与评级。

2 引用标准2.1 GB 150 《钢制压力容器》2.2 JB 4730-94 《压力容器无损检测》2.3 JB4126 《超声波检验用钢制试块的制造和控制》2.4 ZBJ04 001《A型脉冲反射式超声探伤仪通用技术条件》2.5 ZBY230 《A型脉冲反射式超声探伤仪通用技术条件》2.6 ZBY231 《超声探伤用探头性能测试方法》3 人员要求3.1 从事超声波探伤的检测人员应严格按《特种设备无损检测人员考核与监督管理规则》的要求,经培训考核取得特种设备安全监察机构颁发的有效资格证,从事与考核项目及级别相应的无损检测工作。

3.2 应具有丰富的超声波检测经验,掌握一定的材料、焊接基础知识。

3.3 超声波检测人员的视力应每年检查一次,校正视力不低于1.0。

3.4报告编制、审核人资格不低于UTⅡ级,初级人员从事超声波检测辅助工作。

4检测仪器、试块、耦合剂4.1 检测仪器应采用A型脉冲反射式超声波探伤仪,其工作频率范围为2.5~5mHz。

仪器至少在荧光屏满刻度的80%范围内呈线性显示。

衰减器具有80dB 以上连续可调,步进级每档不大于2dB,其精度为任意相邻12dB误差在±1dB 以内,最大累计误差不超过1dB。

水平线性误差不大于1%。

垂直线性误差不大于5%,在使用过程中,每隔三个月仪器水平线性和垂直线性进行一次测定。

测定方法按ZBY 230规定进行。

4.2 探头4.2.1 斜探头声束轴线水平偏离角不应大于2°,主声束垂直方向不应有明显的双峰。

4.2.2 斜探头每个工作日应在标准试块上校准试块上校准前沿距离、K值和主声速偏离。

4.3 仪器和探头的系统性能在达到所探工件的最大检测声程时,其有效灵敏度余量应大于或等于10dB。

【超声二级取证】UT工艺试题

【超声二级取证】UT工艺试题

四、工艺题:(20分)一、请按JB/及有关标准要求,审查超声波检测工艺卡中带括号的部份。

你以为正确的在括号内画“O”,以为错误或不足的在括号内填入正确答案。

工艺卡编号:UT-2005-11二、检测时,在Z1焊缝中处发觉1#长12mm和2#长14mm两个缺点,缺点在一条直线上(如以下图)深度10mm,缺点间距为10mm,依照JB/《承压设备无损检测》标准,该焊缝应评为几级?(III)四、填写工艺卡(20分)有一在制承压设备—贮气罐,规格:Φ2600×16×9000mm,材质:16MnR,对接焊接接头采纳双面自动焊,焊缝宽度均为25mm, 焊接接头要求进行超声波检测,检测标准JB/-2005,检测比例 20%,合格级别Ⅱ级。

产品编号为05-30。

填写以下工艺卡超声检测工艺卡超声波检测工艺卡三、工艺题(共20分)1. 请按JB/T4730(2005)及有关标准要求,审查超声波检测工艺卡中带括号的部份。

你以为正确的在括号内画“O”,以为错误或不足的在括号内填入正确答案。

(16分)2. 检测时,在Z1焊缝中处发觉1#长12mm和2#长20mm两个缺点,缺点在一条直线上(如以下图)深度20mm,缺点间距为10mm,依照JB/T4730-2005《承压设备无损检测》标准,该焊缝应评为几级?(II)一、工艺题(共20分。

)1、以下是某锅炉制造厂的锅筒焊缝超声波查验报告,请指出报告填写中的错误并写出正确的答案。

无损检测报告(焊缝)超声检测报告二、厚度为12mm的钢制压力容器对接焊缝中,存在一条长度为10mm,位于Ⅱ区的条状缺点,依照JB4730-94标准,用超声波探伤,该缺点应评为几级?2、某容器制造公司一台卧式容器,规格为Ф4600×12200×40㎜,筒体上有一插入式接管,焊缝为全焊透形式,规格为Ф600×34㎜。

现进行超声波探伤,请回答以下问题?A、筒体对接焊缝的检测面和探头选择有何要求?(2分)B、筒体纵焊缝检测,缺点定位是不是需要修正?(2分)C、管座角焊缝的检测面及探头规格如何选择?(2分)D、确信筒体对接焊缝检测灵敏度(EL线、SL线及RL线)?(2分)E、若是该容器是液化石油气储罐,筒体对接焊缝还应该选用何种无损检测方式?(2分)三、工艺题(每题15分,共15分)3、某锅炉制造公司生产一台MG-1025/型锅炉,锅筒规格为Ф1743×145mm,筒体纵环焊缝采纳埋弧自动焊。

标准结构UT工艺(英文---5页)

标准结构UT工艺(英文---5页)

ULTRASONIC TESTING PROCEDURE (STRUCTURE)EQUIPMENTUltrasonic Test Instrumenta) The ultrasonic test instrument shall be the pulse-echo type suitable for use withtransducers oscillating at frequencies between 2 and 6 MHz.b) The instrument’s display shall be an “A” scan rectified video trace. The dynamic range ofthe display shall be such that a difference of 1dB of amplitude can be easily detected on the display.c) The horizontal linearity of the test instrument shall be qualified within 1% over the fullsound path distance to be used in testing.d) The instrument shall also provide a amplifier linearity within 5% of full screen height.e) The instrument shall have a calibrated gain (Attenuation) electrically accurate to within plusor minus 2dB over a range of not less than 60 dB.f) Each instrument-transducer combination shall be capable of producing a minimum 3/4CRT vertical scale deflection from an echo received from the 4 in. radius curved surface of the IIW calibration block with a minimum of 40 dB amplification in reserve .ProbeProbes as a straight beam probes 0 degree and angle beam probes of 45, 60 and 70 degree. The selection of probe shall be in accordance with client specification and actual WPS ( thickness, welding bevel, etc.)Straight beam probea) Straight beam probes shall be round in shape and shall have an active area of not lessthan 12.5 mm in diameter nor more than 25 mm in diameter maximum.b) The frequency shall be between 2 to 5 MHz.c) Probes of other sizes and frequencies may be used provided they are qu alified asdescribed in API RP 2X code and approved by client.4.2.2 Angle beam probea) The oscillating element shall be approximately square / or round in shape with dimensionswhich result in an included beam angle of approximately 15 degrees at 6 dB less than the centerline maximum.b) A probe with a transducer element in size from 8 to 13 mm in width and 9 to 13 mm inheight operating at 2 to 5 MHz shall be mostly used in accordance with the code’s recommendations.c) The probe shall produce a sound beam in the material being tested within 2 degrees ofone of the following proper angles: 45, 60 and 70 degrees.The actual angle shall be checked or verified during calibration for testing and reported on the applicable test report.d) Each probe shall be clearly marked to indicate the frequency of the transducer, nominalangle of reflection and index point. Probes of other sizes and frequencies may be used provided they are qualified as described in API RP 2X and approved by client.e) The resolution of the angle probe shall be evaluated with the instrument controls set atnormal test settings and with indications from the holes brought to midscreen height.Resolution shall be sufficient to distinguish at least the peaks of indications from the three holes.Periodic CalibrationThe instrument shall be periodically checked in accordance with the “Calibration Procedure of Ultrasonic Flaw Detector”.All ultrasonic flaw detectors shall be calibrated by a recognized test authority. CALIBRATION AND REFERENCE BLOCKSIIW and IOW standard blocks shall be used for the calibration of UT instrument.The reference blocks according to XXXXXXCALIBRATION FOR TESTINGCalibration for sensitivity and horizontal sweep range shall be made by the ultrasonic technician just prior to and at the location of testing of each weld.For this purpose, the reject (suppression) control shall be turned off.Calibration for Straight Beam TestingCalibration for straight beam testing of base metal shall be made with the probe applied to Face A of the base metal and performed as follows.a) Sweep RangeThe horizontal sweep shall be adjusted for distance calibration to present the equivalent of at least three plate thickness on the CRT screen.b) Reference Sensitivity LevelThe sensitivity shall be adjusted at a location free of indication so that the first back reflection from the side of the plate will be 50 to 75% of full screen height.Calibration for Angle Beam T estingSweep RangeSweep range calibration shall include as a minimum the entire sound path distance to be used during the specific testing by using the IIW block.Standard Sensitivity LevelStandard sensitivity for testing of production welds shall be the Basic Sensitivity Level.corrected for distance by a Distance-Amplitude-Correction Curve established with the Reference Block and modified by Transfer Correction.c) Basic Sensitivity LevelReference level screen height shall be obtained using maximum reflection from the diameter hole in the Reference Block.The amplitude from the reflectors in reference block shall be adjusted to 100% DAC. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld.d) Distance Amplitude Correction (DAC)The Reference Level shall be adjusted to provide for attenuation loss throughout the range of sound path to be used, by DAC curve.The reference block shall be used and curves which are 100% and 50% of reference curve are to be constructed as follows:e) Transfer Correction∙The reference level shall be adjusted to compensate for the differences in surface character and attenuation between the reference block and the material being tested, by means of the double probe technique.∙ A transfer correction shall be performed and recorded once for each welded joint to be tested using part of the test surface exhibiting the roughest condition, except for repetitive testing of the same materials, size and configuration, in which case a transfer correction shall be performed at the beginning of every shift by the ultrasonic operator. Calib ration surfaces shall closely match that of the test surface to minimize corrections required.PRODUCTION TESTING PROCEDURESurface PreparationThe surfaces of welds and base metal shall be prepared as follows:a) Contact surfaces shall be free of weld spatter and any condition that might interfere withfree movement of the search unit or impair coupling of ultrasonic vibrations to and from the material examined. When the correction factor has been determined and used see par. 6.3.e.b) Finished weld surfaces shall be adequate to prevent interference with interpretation of theexamination.c) Surfaces of the calibration reference blocks shall be of a similar finish to the part underexamination.Couplanta) A couplant material shall be used between the search unit and the test material. Thecouplant shall be either glycerin on cellulose gum and water mixture of a suitable consistently.A wetting agent may be added if needed. Light machine oil may be used for couplant oncalibration blocks.b) Components may be tested using the same or different couplant as that used forsensitivity calibration.Scanning ProcedureStraight Beam Technique and Scanninga) At the time of test and prior to angle beam scanning of the weld, the entire base metalthrough which sound will pass during angle beam testing (determined by maximum surface distance required from the weld for the required skip distance) shall be scanned for laminar reflectors or inclusions which might interfere with the examination. If any area of base metal exhibits total loss of back reflection, or if an indication equal to or greater than the original back reflection height is located in a position that will interfere with the normal weld scanning procedure, its size, location, and depth from the face shall be determined and reported separately to Company.b) Where conditions are found to interfere with angle beam testing, other NDT methodsshall be employed.Angle Beam Technique and ScanningGenerala) The technician shall be given the following information before weld testing is commenced,and choice of angle(s) of refraction for scanning weld body sidewalk and reinforcement shall depend on the following factors:∙Type of ferritic steel.∙Groove type used.∙Characteristics and orientation of defects likely to occur i.e., the welding process (WPS) ∙Type of weld joint configuration to be tested i.e., the applicable range of diameter, thickness and local dihedral angle.b) A ccurate profiles shall be taken with wire type profile gauges or, if joint angle is acute, asuitably pliable material able to maintain its shape under normal conditions.Scanning T echniquea) Scanning may be in any pattern which results in full coverage of the root of the weld, thebody of the weld, and both side fusion lines and base metal heat affected zones.b) Scanning shall generally be performed at a gain setting 6dB above the ReferenceSensitivity Level for the maximum sound path. Evaluation of indications shall be done with the gain control at the Reference Level.Selection of Probesa) The nominal frequency shall be 2 to 5 MHz, unless variables, such as fabrication materialgrain structure require the use of other frequencies to assure adequate penetration or better resolution.b) Indications found in the root areas of groove welds in butt joints and along the fusion face ofall welds shall be further evaluated with either 70, 60, or 45 deg. angles, whichever is nearest to being perpendicular to the expected fusion face.Scanning PatternsFor girth welds, scanning for volumetric examination shall be carried out from both sides of the weld on the same surface.Indication InvestigationThe indications shall be investigated by maximising the echoes by rotating the probes and by using different angle probes with DAC curves. All indications exceeding 20% of the ref erence curve shall be investigated with and all indications exceeding 50% shall be reported.Investigation shall be performed to the extent that the operator can determine the shape and location of the indication. For dimensional evaluation, either the “6 dB-drop” method or time of flight or maximum amplitude method shall be used.DISCONTINUITY EVALUATIONGenerala) Once a reflector has been found by scanning, it shall be carefully evaluated to determinethe following characteristics, as required for application of the Acceptance Criteria and for Reporting:∙Location from an established reference point.∙Location within the weld cross section.∙Sizes - i.e., length along the weld axis and width (height dimension) as seen in the weld cross section, or amplitude relative to reference level.∙Type and Orientation - i.e., classify as linear, planar or spherical reflectors. If planar, the orientation of the plane relative to the brace or chord side fusion boundaries.b) Discontinuities shall be evaluated by use of a combination of Beam Boundary andAmplitude Techniques.Defect Size DeterminationThe following technique shall apply to determine the defect size.a) The length of the discontinuity shall be obtained by recording the location along the lengthof weld as determined by 50% of Reference Level (6dB drop) for each end of the reflector.b) The width (height) of the discontinuity shall be determined by 20dB drop (10% intentensityof the maximum echo) technique.Acceptance StandardAcceptance criteria are as Client’s Spec ification and xx code (根据实际要求)。

ut工艺规程和操作指导书(1)

ut工艺规程和操作指导书(1)

UT检测工艺一、检测工艺文件检测工艺文件包括工艺规程和操作指导书。

二、超声检测工艺规程→超声检测工艺规程应根据相关法规、安全技术规范、产品标准、有关的技术文件和NB/T 3-2015等相关检测标准要求,并针对检测机构的特点和检测能力而编制的技术文件。

→超声检测工艺规程应涵盖本单位(制造、安装或检验检测单位)产品(或检测对象)的检测范围。

→超声检测通用工艺规程一般以文字说明为主,检测对象一般为某类工件,它应具有一定的覆盖性和通用性。

工艺规程的编制要点(1)涵盖本单位的检测范围,是通用性技术要求、原则性指导文件;(2)根据检测单位的特点和能力编写,是对现行标准规范的补充;(3)内容不能照搬照抄外单位的文件,必须有本单位的特色;|(4)跟具体的工程项目没有必要的关联,是检测单位自身检测能力的体现;(5)由检测单位Ⅲ级专业人员编制,检测责任师审核,单位技术负责人批准;(6)规程中某一项技术要求需要展开说明的,可采用附录形式编入;(7)不得将管理制度、操作规程等与工艺规程无关的内容写入正文;(8)工艺规程要完整,一些关键的数据和指标应明确写入规程中,以供检测人员使用;(9)工艺规程的编制应按NB/~的规定明确其相关因素的具体范围或要求,如相关因素的变化超出规定时,应重新编制或修订。

(10)相应检测标准变更、采用新的检测工艺时,应对工艺规程进行修订,重新审批发布。

(如果来不及修订工艺规程时,所编制的操作指导书应由检测单位技术负责人批准)。

工艺规程的编制原则(1)遵照国家现行标准和法规的要求,在检测工艺上可以比现行标准、法规更细,更具体,要求更高;(2)应根据本单位无损检测人员技术水平、检测能力,做到简明扼要,提出切实可行的工艺措施;(3)应采用本单位一些行之有效的做法,应有自己的特色;`(4)工艺规程中每一步骤都要写清楚做什么、由谁去做、采用什么设备和辅助器材、什么时机做、按什么标准做;(5)采用非标准检测工艺(如非标准温度范围内的渗透检测、探头移动区不符合要求的超声波检测、焦距不符合要求的射线检测等)时,应对该检测工艺进行验证;(6)明确对操作人员和责任人员的职责和要求;(7)要融入其它施工质量验收规范中有关无损检测方面的内容(如SH/T3543-2007 石油化工建设工程项目施工过程技术文件规定条的要求:无损检测单位应按SH/T3503的规定提交无损检测报告。

UT工艺规程

UT工艺规程

超声波检测工艺规程绍兴市力博锅炉制造有限公司二00六年一月一.范围:本规程适用与本公司制造、安装、维修的所有锅炉压力容器中原材料和焊接接头的超声波检测。

原材料包括钢板、锻件等。

用于制作焊接接头的材料包括碳素钢、不锈钢、低合金钢。

焊接方法为手工焊、埋弧自动焊、氩弧焊等。

检测仪器采用A型脉冲反射式超声波探伤仪检测工件缺陷。

二.术语和定义超声标准试块:JB/T4730-2005.3规定的用于超声仪器探头系统性能校准和检测校准的试块。

三.一般要求:1.检测人员资格证需经省考委会考试合格后取得。

Ⅰ级人员从事检测操作,记录检测数据。

Ⅱ级人员编制检测工艺卡能进行独立操作,整理资料,评定检测结果,签发报告。

2.超声检测设备均应具有产品质量合格证或合格的证明文件。

3.探伤仪检测设备采用A型脉冲反射式超声波探伤仪,其工作频率范围为0.5-10MHZ。

仪器至少在荧光屏满刻度的80%范围内呈线性显示.水平线性误差不大于1%,垂直线性误差不大于5%。

4.探头:直探头采用一般∮20mm、∮10mm晶片面积不大于500m2。

单斜探头声束轴线水平偏离角应不大于2°,主声束垂直方向不应有明显双峰。

5.超声探伤仪和探头的系统性能:在达到所探工件的最大检测声程时,其有效灵敏度余量应不小于10dB。

仪器和直探头的始脉冲宽度(在基准灵敏度下),对于频率为5MHZ的探头宽度不大于10mm, 对于频率为2.5MHZ的探头宽度不大于15mm。

直探头的远场分辨率应不小于30dB,斜探头的远场分辨率应不小于6dB。

四.超声检测一般方法1.检测前准备本公司制造、安装、维修的所有锅炉压力容器中原材料和焊接接头的超声波检测中,检测时机及抽检率应按锅规容规和有关技术文件的规定。

所确定的检测面应保证工件被检部分能得到充分检查。

焊缝的表面质量应经外观检验合格。

根据本公司检验科下达的无损检测委托单核实被检工件的检测时机、材料厚度、焊缝长度、检测比例、合格标准、合格级别等有关要求。

UT工艺卡(锻件)

UT工艺卡(锻件)

学号超声波探伤工艺卡(锻件)试件编号仪器型号标准试块时基线比例表面状况执行标准操作步骤:1.确定使用标准、检查范围、测量试件规格;2.确定探伤方法及检测面,选定探伤仪器、探头;3.将探头对准标准试块CSK-ⅠA上厚为100mm的底面,调节深度微调和延迟旋钮,使底波B1和B2分别对准水平刻度50、100,这时仪器时基线比例深度1:2就调好了;4.根据公式:20lg××××CTS-22CSK-ⅠAxx1:2机加工JB/T4730.3-2005试件材料探头型号灵敏度试块检测面表面补偿验收等级碳钢编号:UT/D-2011-001试件规格100×100×125(B1-34dB)2.5MHzφ20基准灵敏度125/Φ2工件大平底上端面0 dBⅡ级合格扫查灵敏度扫查方式耦合剂记录要求125/Φ2-6dB全面扫查机油≥Φ2平底xx2x22.3612520lg34dB,计算工件大平底与同声程Φ2平22 Df3.14 2底孔的dB差值,调节基准灵敏度的方法:将探头对准工件大平底完好部位,调节衰减旋钮使底波B1达到80%;然后提高34dB,这时125/Φ2mm灵敏度就调好了;5.对锻件进行探伤,确定锻件上缺陷的数量、位置、深度和缺陷回波的幅值;6.根据公式:20lgPf1Pf2Df1440lgDf1x2Df2x140lgDf11252x1,计算缺陷的当量大小;7.根据公式:40lg,计算缺陷的当量大小(φ4+ΔdB);8.根据标准对缺陷进行评级,得出结论;9.对仪器的时基线及灵敏度进行复验;10.对工件及操作现场进行清理。

检测示意图:编制人及资格日期UT-(Ⅱ)Ⅲ级2011.3.30审核人及资格日期UT-Ⅲ级2011.3.30。

UT通用工艺规程

UT通用工艺规程

1 适用范围1.1 本规程适用于公司承压设备采用A型脉冲反射式超声仪检测工件缺陷的超声检测方法和质量分级。

1.2 本规程适用于金属材料制承压设备用原材料或零部件和焊接接头的超声检测,也适用于金属材料制再用承压设备的超声检测。

1.3 本规程规定了承压设备厚度的超声测量方法。

1.4 与承压设备有关的支撑件和结构件的超声检测,也可参照本规程。

2 依据标准TSG R0004-2009 《固定式压力容器安全技术监察规程》GB150-2011 《压力容器》NB/T47013-2015 《承压设备无损检测》3 术语和定义本规程引用设术语和定义按照NB/T47013.1中第3条款及NB/T47013.3中第3条款的界定。

4 检测人员4.1 超声检测检测的人员应满足NB/T47013.1的有关规定。

4.2超声检测人员应具有一定的金属材料、设备制造安装、焊接及热处理等方面的基本知识,应熟悉被捡工件的材质、几何尺寸及透声性等,对检测中出现的问题能作出分析、判断和处理。

5 检测设备和器材5.1 推荐使用下面的超声仪仪器型号产地HS600 武汉中科PXUT-350C 南通友联5.2 检测仪器、探头和组合性能5.2.1检测仪器采用A型脉冲反射式超声检测仪,起工作频率按-3dB测量应至少包括0.5MHz-10MHz频率范围,超声仪器各性能的测试条件和指标要求应满足NB/T47013.3附录A的要求并提供证明文件,测试方法按GB/T27664.1的规定。

圆形晶片直径一般不应大于40mm,方形晶片任一边长一般不应大于40mm,其性能指标应符合NB/T47013.3附录的要求并提供证明文件,测试方法按GB/T27664.2的规定。

5.2.3 仪器和探头的组合性能5.2.3.1 仪器和探头的组合性能包括水平线性、垂直线性、组合频率、灵敏度余量、盲区(仅限直探头)和远场分辨力。

5.2.3.2 新购置的超声检测仪器和探头,或仪器和探头在维修或更换主要部件后及检测人员有怀疑时应测定仪器和探头的组合性能。

UT三级工艺题带答案

UT三级工艺题带答案

模拟综合题(49分)1500m³低温乙烯球罐,采用国产07MnNiCrMoVDR制造,该钢种为调质钢,具有较明显的再热裂纹倾向,其σb =610 ~740MPa , σs ≥490MPa ,X型坡口,其外形如图1所示,主要参数如下:容器类别:Ⅲ类:设计压力:2.2 MPa:设计温度:-40~50℃:焊缝系数:1规格:φ14200×44mm: 容积:1500㎡ :腐蚀余量:1.5mm :充装系数:0.9上级图1 1500mm³07MnNiCrMoVDR乙烯球罐示意图1,改球罐的制造与检测,应遵循那些法规和标注的要求?(5分)①GB150-2011 《压力容器》②TSG R004-2009 《固定式压力容器安全技术监察规程》③GB/T4730-2005 《承压设备无损检测》④GB12337-1998 《钢制球形储罐》⑤GB50094-2010 《球形储罐施工规范》2.按照有关法规和标准,该储罐现场组焊过程中要进行哪些超声检测?请写出探伤对象、比例、实施时机、合格级别。

答:(1)球罐组焊前对球壳板进行超声波抽检,抽查数量不得少于球壳板总数的20%,且每带不应小于2块,上、下板不应少于1块;若发现超标缺陷,应加倍抽查,若仍有超标缺陷,则应100%检测,GB/T4730-2005 Ⅱ级合格。

(2)对接焊缝应在焊接结束36小时后进行100%UT,GB/T4730 Ⅰ级合格(3)如选择100%RT检测焊缝,同时应进行20%的UT复检包括焊缝丁字接头,GB/T4730 Ⅰ级合格。

(4)球壳板表面焊补深度超过3mm时,应进行UT检测(GB12337 8 7.2条)3.球罐组焊前对球壳板进行超声波抽检,球壳板尺寸为6635×2552×44mm,请按GB/T4730-2005标准,确定超声检测方法,包括探头、试块、灵敏度校验和扫查方式。

答:(1)探头: 2.5P20Z(2)试块: CBⅡ-2(3)灵敏度校验:把试块5平底孔第一次反射波高调整到满刻度的50%作为基准灵敏度。

钢板自动UT检测工艺

钢板自动UT检测工艺
13.耦合剂:水;水膜厚度0.3~0.5mm
14.报警:自动
15.缺陷标记:自动喷标
16.验收标准:
1)未产生触发/报警的钢板判为合格。
2)产生触发/报警的钢板视为可疑,使用本设备重新复探,如未产生触发/报警,判为合格。如仍触发报警,则采用手工超声波进行探伤,采用半波幅法测定分层缺欠范围。合格评定:
板头150mm及板边50mm不允许存在分层;
其它部位:任何方向不允许存在长度超过50mm的分层;长度在30mm~50mm的分层相互间距应大于500mm;长度小于30mm、相互间距小于板厚的若干小分层构成连串性分层,该连串性分层中的所有小分层长度总和不得大于80mm。
备注:
不合格品处置:标明分层位置、尺寸、切除或另作它用。
7.灵敏度:Φ6mm平底孔或矩形刻槽100%反射波高。
8.校验方式:探头沿标样板面扫查使矩形刻槽触发报警。
9.灵敏度校验频次:1次/4小时,且关机后每次开机前应校验一次灵敏度
10.最小覆盖范围: 板边50mm,板端150mm范围内100%检测;其余位置:覆盖范围≥50%。
11.探伤比例:100%.
12.检验速度:≤校验速度;
钢板自动超声波检测工艺卡
订单
技术标准
Байду номын сангаас材质
钢板规格
要求:
1.检测方式:双晶探头纵波脉冲反射法
2.仪器:自动:
3.表面条件:板面应平整及无影响检测有效性的异物。
4.探头型号:
5. 探头排布: 梳状阵列式(多平行带)。
6.标样:深度为:T/4<H<T/2的Φ6mm平底孔(T-公称壁厚)或长20mm宽6mm矩形刻槽

UT探伤工艺

UT探伤工艺

无损检测工艺坡口焊缝的超声波检测上海振华港口机械(集团)股份有限公司常州基地质检部探伤室坡口焊缝的超声波检测工艺1. 主题内容与适用范围本标准适用于ZPMC制造起重机械如集装箱岸桥和场桥、卸船机、散货机等起重机械钢结构焊缝的超声检测。

每种无损探伤方法均有优点和局限性,各种方法对缺陷的检测几率也不会相同,超声探伤(UT)方法主要用于检测被检物的内部缺陷。

本工艺与标准适用于指导厚度在 8mm和200mm之间、包括这两个厚度在内的坡口焊缝和热影响区进行的超声检测。

这些工艺和标准不适用于管材与管材的T、Y或K形连接焊缝的检测。

母材这些工艺不打算用于母材采购的检测。

不过,与焊接有关的、在邻近(焊缝的)母材中出现的、按本规范条款为不合格的不连续(开裂,层状撕裂,分层等),必须报告工程师处理。

2. 引用标准ANST/AWS 美国国家标准-钢结构焊接规范JB 4730-1994 中国机械行业标准压力容器无损检测3. 超声探伤人员资质审定只有取得专业认证机构颁发NDT UT-II级及II级以上资格的人员才可以独立进行超声检测、签发报告。

资质审定按GB9445进行,由书面考试和用以证明操作能力的操作考试组成,操作考试应使用生产中检验焊缝所用的专用设备和规程。

这一考试必须要求超声操作人员证明其具有应用本规范规定准确探测和处理检测结果的能力。

4. 超声设备设备要求超声仪器必须为脉冲反射式探伤仪,配用振荡频率为1~6MHz的换能器。

显示必须为整流的视频扫描的A型显示。

水平线性检测仪器的水平必须按“AWS :2002版钢结构焊接规范”6.30.1在检测所用的全声程距离内进行鉴定。

检测仪器要求检测仪器必须带有内部稳压装置,使得温升后当额定供电电压变化15%、或在使用电池情况下整个充电使用寿命时间内,响应变化不大于±1dB。

必须装一警报器或仪表,以便在电池耗尽而仪器切断之前,发出电池电压下降信号。

检测仪器的校准检测仪器必须有校准用增益(衰减)控制器,它应至少在60dB的整个范围内每档1dB或2dB间断可调。

超声检测UT工艺题与综合题解析与课件总结

超声检测UT工艺题与综合题解析与课件总结

3、试块 (1)、JB/T4730.3-2005要求: 4.2.3.1 单直探头标准试块 采用CSⅠ试块,其形状和尺寸应符合图4和表4的
规定

mm
D 50 60 80 80
表4 CSⅠ标准试块尺寸 试块序号 L CSⅠ-1 50 CSⅠ-2 100 CSⅠ-3 150 CSⅠ-4 200
4.2.6.1 单直探头基准灵敏度的确定
也可以使用CSⅠ-4试块校验灵敏度。 检测深度350mm, △dB=20lgPf1/Pf2=40lgX2/X1=40lg350/200 ≈10dB, 检测深度600mm, △dB=20lgPf1/Pf2=40lgX2/X1=40lg600/200 ≈19dB.
4、耦合补偿 试块3dB或实测,大平底0dB。
6)、距离-波幅曲线的灵敏度选择 a) 壁厚为6mm~120mm的焊接接头, 其距离-波幅曲线灵敏度按表19的规 定。 b) 壁厚大于120mm~400mm的焊 接接头,其距离-波幅曲线灵敏度按 表20的规定。 c) 检测横向缺陷时,应将各线灵敏 度均提高6dB。
超声检测工艺题 与综合题解析
许遵言
上海电气核电设备有限公司
工艺题1
1、对一在制高压容器机加工锻造 封头进行超声波检测,具体尺寸 见下图,锻件材料号:20MnMo; 超声波检测及验收标准执行 JB/T4730.3-2005《承压设备无 损检测 第3部分:超声检测》; 锻件合格等级按Ⅱ级验收。
解释: 1、探头: (1)、JB/T4730.3-2005要求: 4.2.2 双晶直探头的公称频率应选用5MHz。 探头晶片面积不小于150mm2;单晶 直探头的公称频率应选用2~5MHz, 探头晶片一般为φ14~φ25mm。 (2)、选择探头2.5P25Z

T K Y 型管接点焊缝UT检验工艺

T K Y 型管接点焊缝UT检验工艺

1.5.3 T K Y型管状焊缝缺陷定位基准点数量确定的基本原则
T型焊缝可定4个基准点,也可定两个基准点,因为 T型焊缝可按支管直径四等分,而Y(K)型焊缝不可等 分,因此,把基准点a和C两个点均定在主管的工艺线 上,操作性强且准确。用这种方法定基准点也为使用 微机辅助做焊逢缺陷定位分析打下了基础。只设两个 基准点测量X值时,由于其距离大可能遇到困难,但是 ,在两个基准点附近的缺陷,测量X值时只要按示意图 所示方向用“+”“-”X值就很方便。
①取样操作:
海洋石油工程股份有限公司
地址:天津市塘沽区河口街 2-37 邮编:300452
OFFSHORE OIL ENGINEERING CO., LTD.
8
在Y型焊缝上缺陷波反射最高处用万能取形规取样 见图-2
1
2
3
1、Y形管焊缝 2、3用万能取形规在Y形管焊缝上缺陷最高 波 处量取管焊缝外形 4、万能取形规量取管焊缝外形之情形效果
T K Y 型管接点焊缝
超声波检验 工 艺
(适用API RP-2X-[A\C 级]、AWS D1.1标准)
邢树宏
二 ○ ○ 六 、七
海洋石油工程股份有限公司检验公司
地址:天津市塘沽区河口街 2-37 邮编:
OFFSHORE OIL ENGINEERING CO., LTD
.2
自我介绍
邢树宏 服务单位 海洋石油工程股份有限公司检验公司 检验资格ABS UT二级/NDT检验技师
取样;
(四) 补图操作时一定按原取样位置重新量取主、支管曲率; (五)摸拟定位操作时所采用相关尺寸数据应是实际测量数据 。
海洋石油工程股份有限公司
地址:天津市塘沽区河口街 2-37 邮编:300452

UT 探伤工艺 翻译版

UT 探伤工艺 翻译版

巴基斯坦CMEC项目机电超声波检测工艺1.依据标准ReferenceASME 第V 卷第5章(2007年). ASTM第Ⅷ卷第一册(2001年); GB11345-89钢焊缝手工超声波探伤方法和探伤结果分级ASME Section V, Chapter 5 (2007); ASTM Section Ⅷ, Division 1 (2001)GB11345-89:Method for Manual Ultrasonic Testing and Classification of Testing Results for Ferritic Steel Welds.2.人员资格Personnel Qualification从事本工程超声波检测的人员,应经过专门的职业资格培训,并取得国家有关部门颁发的Ⅱ级以上UT检验资格证书,并负相应的技术责任。

The UT inspector in this project shall receive the vocational qualifications training and gain the qualifications certificate which is equal or above Level Ⅱissued by the related national authority, and take the technical responsibility.3.仪器设备Instrument4.1仪器Instrument使用HS620型数字式超声波检测仪。

HS620 Digital Ultrasonic Detector4.2探头Probe使用2.5P9×9K3、2.5P13×13K2、2.5P13×13K1等型号的横波斜探头Angle probes with transverse wave including 2.5P9×9K3、2.5P13×13K2、2.5P13×13K1 will be used.4. 耦合剂couplant5.1耦合剂:工业浆糊。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

超声波探伤通用工艺1 总则1 适用范围本工艺适用于公司承接的电站及其他各类钢制锅炉、压力容器及压力管道母材厚度为6mm~400mm全焊透熔化焊对接焊接接头的超声检测对接焊接接头的超声检测和质量等级评定1.2 编制依据1.2.1 《钢制压力容器》 GB1501.2.2 《蒸汽锅炉安全技术监察规程》劳部发<1996>276号1.2.3 《压力容器安全技术监察规程》质技监局锅发<1999>154号1.2.4 《承压设备无损检测》 JB/T4730—20051.2.5 《管道焊接接头超声波检验技术规程》 DL/T 820-20021.2.6 《电力建设安全工作规程(第一部分:火力发电厂)》 DL5009.1-20021.2.6 《火力发电厂焊接技术规程》 DL/T869-20042 检验人员2.1 超声波探伤工作人员,必须取得国家质量技术监督局无损检测人员资格考核委员会颁发的资格证书,探伤报告必须由Ⅱ级或Ⅱ级以上的超声波探伤人员编写,并由技术负责人或授权签字人签发。

2.2 探伤人员应熟悉本作业指导书的各条规定,并能按规定的探伤工艺熟练地操作。

2.3 探伤人员必须遵守现场安全规程和其它有关规定。

3 准备工作3.1 技术准备3.1.1 根据检验协议及客户提交的《金属试验委托单》了解检测规范、被检工件材质、规格、焊接工艺、热处理工艺等。

3.1.2 确定检验比例、检验数量、检验工作质量等级、受检工件质量验收级别。

检测时机及抽检率的选择等应按法规、产品标准及有关技术文件的要求和原则进行。

3.2 现场情况及现场准备3.2.1 了解被检工件结构、焊接位置、坡口型式、内壁加工情况、对口间隙、焊缝的中心位置和环境情况。

并对现场安全设施及检测环境进行评价。

3.2.2 对焊接接头的表面质量及外形尺寸应进行检查,对有影响检验结果评定的表面形状突变应进行适当的修磨,并做圆滑过渡,内壁加工面应满足超声波检验的要求。

3.2.3 探测面探头移动区应清除飞溅、锈蚀、氧化物及油垢。

必要时,表面应打磨平滑,打磨宽度至少为探头移动范围。

a)采用一次反射法探测时,探头移动区应大于1.25PP=2t tgβ,式中:P—跨距,mm;t—管壁厚度,mm; β—探头折射角,(O)。

b)采用直射法探测时,探头移动区位大于0.75P。

3.3 工艺制订根据本工艺及有关标准规定及现场情况等制订工艺卡,确定探伤仪、试块、探头及扫描比例、探测灵敏度、探测方式等。

以上参数参见具体检验项目的《超声波探伤工艺卡》。

3.4 器材准备及仪器、探头性能的测试选择的器材、调整的具体参数参看《超声波探伤工艺卡》。

3.4.1 探伤仪3.4.1.1 采用A型脉冲反射式超声波探伤仪。

其工作频率范围为0.5MHz~10MHz,仪器至少在荧光屏满刻度的80%范围内呈线性显示。

探伤仪应具有80dB 以上的连续可调衰减器,步进级每档不大于2dB,其精度为任意相邻12dB误差在±1dB以内,最大累计误差不超过1dB。

水平线性误差不大于1%,垂直线性误差不大于5%。

3.4.1.2 超声探伤仪和探头的系统的组合性能不低于下列指标:a 在达到所探工件的最大检测声程时,其有效灵敏度余量应不小于10dB。

b 仪器和直探头组合的始脉冲宽度(在基准灵敏度下):对于频率为5MHz的探头,宽度不大于10mm;对于频率为2.5MHz的探头,宽度不大于15mm。

c 直探头的远场分辨力应不小于30dB,斜探头的远场分辨力应不小于6dB。

3.4.1.3 仪器的校准在仪器开始使用时,应对仪器的水平线性和垂直线性进行测定。

在使用过程中,每隔三个月至少应进行一次测定。

3.4.2 探头3.4.2.1探头K值选择推荐采用下表:斜探头的K值(角度)选取可参照下表的规定。

条件允许时,应尽量采用较大K值探头。

板厚T,mm K值6~25 3.0~2.0(72°~60°)>25~46 2.5~1.5(68°~56°)>46~120 2.0~1.0(60°~45°)>120~400 2.0~1.0(60°~45°)3.4.2.2 探头测定a) 斜探头置于标准试块上探测棱边,当反射波幅最大时,探头中心线与被测棱边的夹角应在90°±2°的范围内。

b) 斜探头主声束在垂直方向不应有明显的双峰或多峰。

c) 探头的中心频率允许偏差为±0.5MHZ3.4.2.3 探头的校准在新探头开始使用时,应对探头进行一次全面的校准a) 斜探头使用前,至少应进行前沿距离、折射角、主声束偏离、灵敏度余量和分辨力等的校准。

使用过程中,每个工作日应标准前沿距离、折射角和主声束偏离。

b) 直探头的始脉冲占宽、灵敏度余量和分辨力应每隔一个月检查一次。

3.4.2.4 纵向对接接头检验探头的要求a)纵向对接接头的探头应根据管件的曲率和壁厚选择探头角度,并考虑几何临界角的限制。

条件允许时,声束在曲底面的入射角不应超过70°。

b)探头接触面修磨后,用曲面试块实际测定探头入射点和折射角。

3.4.3 仪器的校验3.4.3.1 每次检测前均应在对比试块或其他等效试块上对扫描线、灵敏度进行校验,校验过程中使用的试块与被检管件的温差不大于15℃。

遇有下述情况应随时对其进行重新核查:a) 校准后的探头、耦合剂和仪器调节旋钮发生改变时;b) 开路电压波动或者检测者怀疑灵敏度有变化时;c) 连续工作4h以上时;d) 工作结束时。

3.4.3.2 时基调节校验时,如发现校验点反射波在扫描线上偏移超过原校验点刻度读数的10%,则扫描比例应重新调整,前次校验后已经检验的焊接接头要重新检验。

3.4.3.3 灵敏度校验时,如校验点的反射波幅比距离—波幅曲线降低2dB以上,则仪器灵敏度应重新调整,并应重新检验前次校验后检查的全部焊接接头。

如校验点的反射波幅比距离—波幅曲线增加2dB以上,则仪器灵敏度应重新调整,对前次校验后已经记录的缺陷进行尺寸参数重新测定并予于评定。

3.4.3.4 距离—波幅曲线复核时,校核应不少于3点。

如曲线上任何一点幅度下降2dB,则应对上一次所有的检测结果进行复检;如幅度上升2dB,则应对所有的记录信号进行重新评定。

3.4.3.5 校准、复核和线性检验时,任何影响仪器线性的控制器(如抑制或滤波开关等)都应放在“关”的位置或处于最低水平上。

3.4.3 试块3.4.3.1 标准试块主要用于测定探伤仪、探制作DAC曲线及系统性能。

采用的标准试块为CSK-ⅠA、CSK-ⅡA、CSK-ⅢA和CSK-ⅣA。

标准试块的尺寸精度应符合要求,并应经计量部门检定合格。

3.4.3.2 对比试块对比试块应选用与被检管材相同或声学性能相近的钢材制作。

对比试块的外形尺寸应能代表被检工件的特征,试块厚度应与被检工件的厚度相对应。

如果涉及到两种或两种以上不同厚度部件焊接接头的检测,试块的厚度应由其最大厚度来确定。

a)环向对接接头检验对比试块的曲率半径为检验面曲率半径0.9~1.5倍的试块均可采用。

b)纵向对接接头检验对比试块的曲率半径与检验面曲率半径之差应小于10﹪。

c)当检验曲面曲率半径R>W2/4,可采用平面对比试块调节仪器。

但检验中应及时修正缺陷深度或水平距离与缺陷实际的径向埋藏深度或水平距离弧长的差异,修正方法参照GB11345相关章节。

d)当检验面曲率半径R≤W2/4时(W为探头接触面宽度,R、W单位均为mm),应采用与检验面曲率相同或相近的对比试块。

在满足灵敏度要求的条件下,可以采用其他型式的试块,并在报告中注明。

3.4.3.3 携带试块用于校验灵敏度和时基线性,可根据需要选择。

3.4.4 耦合剂3.4.4.1 偶合剂应具有良好的润湿能力和透声性能,且无霉、无腐蚀、易清除。

偶合剂对人体不能有损伤作用。

3.4.4.2 在试块上调节仪器和产品检验应采用相同的耦合剂。

4 作业方法及工艺要求4.1 仪器的调整、校验4.1.1 探头参数及性能的测定在CSK-1B试块上测定探头的前沿、折射角、始脉冲占宽和探头分辨力。

4.1.2 时基线扫描的调节4.1.2.1 时基线扫描的调节:时基线刻度可按比例调节为代表脉冲回波的水平距离、深度或声程。

扫描比例依据管件厚度和选用的探头角度来确定,最大检验范围应调至时基线满刻度60%以上。

4.1.2.2 检验面曲率半径R大于W2/4时,应在标准试块或平面对比试块上进行时基线扫描调节。

4.1.2.3 检验面曲率半径R小于等于W2/4时,在规定的对比试块上进行时基线扫描调节。

4.1.3 检验技术等级4.1.3.1 超声检测技术等级选择超声检测技术等级分为A、B、C三个检测级别。

超声检测技术等级选择应符合制造、安装、在用等有关标准及设计图样规定。

4.1.3.2 不同检测技术等级的要求4.1.3.2.1 A级仅适用于母材厚度≥8mm~46mm的焊接接头。

可用一种K值探头采用直射波法和一次反射波法在焊接接头的单面单侧进行检测。

一般不要求进行横向缺陷的检测。

4.1.3.2.2 B级检测:a) 母材厚度≥8mm~46mm时,一般用一种K值探头采用直射波法和一次反射波法在焊接接头的单面双侧进行检测。

b) 母材厚度大于46mm~120mm时,一般用一种K值探头采用直射波法在焊接接头的双面双侧进行检测,如受几何条件限制,也可在焊接接头的双面单侧或单面双侧采用两种K值探头进行检测。

c) 母材厚度大于120mm~400mm时,一般用两种K值探头采用直射波法在焊接接头的双面双侧进行检测。

两种探头的折射角相差应不小于10°。

d) 应进行横向缺陷的检测。

检测时,可在焊接接头两侧边缘使探头与焊接接头中心线成10°~20°作两个方向的斜平行扫查,见图1。

如焊接接头余高磨平,探头应在焊接接头及热影响区上作两个方向的平行扫查,见图2。

4.1.3.2.3 C级检测:采用C级检测时应将焊接接头的余高磨平,对焊接接头两侧斜探头扫查经过的母材区域要用直探头进行检测。

a)母材厚度≥8mm~46mm时,一般用两种K值探头采用直射波法和一次反射波法在焊接接头的单面双侧进行检测。

两种探头的折射角相差应不小于10°,其中一个折射角应为45°。

b)母材厚度大于46mm~400mm时,一般用两种K值探头采用直射波法在焊接接头的双面双侧进行检测。

两种探头的折射角相差应不小于10°。

对于单侧坡口角度小于5°的窄间隙焊缝,如有可能应增加对检测与坡口表面平行缺陷有效的检测方法。

c)应进行横向缺陷的检测。

检测时,将探头放在与焊缝及热影响区上作两个方向的平行扫查,见图2。