上花园变电站主接线图

合集下载

各种变电站电气主接线图

各种变电站电气主接线图

TMY-100X8ZN21-10/1250配CD10ⅢLZZBJ-101000/5 0.5/10P 2×(ZR-YJV 22-6/3×240)RN2-6/0.5ASFWG8000-6/4950Ue=6.3kV Ie=916.45A COSφ=0.8LZX-10Q 800/5 0.5/10PJ Y N 2-10-03(改)1G励磁变(厂家配套)励磁互感器(厂家配套)JDJ-6 36 0.1√3√J Y N 2-10-17J Y N 2-10-18RN2-6/0.5A36 0.1 0.1JDZJ-63√√3J Y N 2-10-20√ 6 0.1 0.1√333JDZJ-6RN2-6/0.5AHY5WZ-10/302G同左ZN21-10/2500配CD10ⅢLFZJ-102000/5 0.5/0.5/10/10PJ Y N 2-10-03SF9-20000/110Y,d11121±3×2.5%/6.3kV U k %=10.5%LGJ-120GW4-110DW/630左接地LW25-1261250A,40kA GW4-110DW/630双接地LCWB 6-110100/50.2/0.5/10P/10PTYD-110/ -0.07H 3√LRD-60-B 50/5GW4-110DW/630双接地JDCF-110Y5W1-100/260√110 0.1 0.13√√33GW 13-60G/400Y1W-73/15ZN21-10/630配CD10ⅢLZZBJ-10100/5 0.5/10PJ Y N 2-10-03ZR-YJV 22-6/3×50SC9-800/6.3D,yn116.3±5%/0.4kV Ud%=7LMZ1-0.5 1200/5LMZ1-0.5 1200/5SC9-800/10D,yn1110±5%/0.4kV Ud%=7ZR-YJV 22-10/3×50LZZBJ-10100/5 0.5/10PZN21-10/630配CD10ⅢJ Y N 2-10-06(改)ZR-YJV 22-10/3×5010kV外来电源J Y N 2-10-19JDZJ-10HY5WZ-17/51RN2-10/0.5A10/0.1kV0.4kVLMY100×8-40×8DW15-1200DW15-1200DW15-12000.1LMY100×8-40×8G~G~TMY-100X8GW4-110DW/630左接地图5-19 某水电站电气主接线全图图5-20 地区变电所接线8回35kV220kV4 回2×120MVA至无功补偿装置6 回2×60MVA4回2×10MVA1T图5-21 终端变电所接线4回10kV2T110kV 35kVVV22-13×50+1×251#厂变进线V42L6-A,0~150A DT864-2,380/220V,3(6A)42L6-V,0~450V说明:BT95O9为事故照明切换板,其直流电源用VV22-1-2×4电缆引至直流屏。

变电站的电气主接线ppt课件

变电站的电气主接线ppt课件
.
220kV变电站电气主接线图
10kV
采 专用用特双母母联别在线断提主接路示线器接22,:0线装采无线kV图设用出单配单线元中电母时接,线则线装各分宜置段采配接用电线单。母 配装置的相对位置应与电气 电总平面图一一对应。

采用双母线接线,装设专用母联断路

110kV配电装置 器。系统位置重要、进、出线回路数10


装器




.
500kV配电装置接线图
采用一个半断路器接线
,在该两接条线设母有线两间条只主母 线有,2在台两断条路主母器线1之间 串一个接个元三完件台整断 串的路 ,称器 每为, 串不组 中成两 台完断整路串器之。间引出一回
线路或一组变压器。
拥有3台断路 器2个元件的 串称为完整串
500kV配电装置
主变压器中性点应通过
.
隔离开关接地。
接地刀闸配置原则
每段母线根据长度配主置出变线进间线隔间断隔路断器路两器侧两隔侧离隔开离
1~2独母立线的设接备地隔刀离闸开,关关均均配配配单置置接接地地刀刀闸闸,,其其中中::
以保证接母地线刀及闸电。器的母检母线母线侧联侧为间为单隔单接断接地路地刀器刀闸两闸,侧,变隔线压离路器
母线母.设线备分间段隔间隔,段该,接母电线线主中之容,间变站器仅通进用设过出一母出线变线组线线间出母联间线络间隔线隔,断隔间母路线器隔分连成接若。干
隔离开关配置原则1
接在母线上的避断雷路器器和两侧均应配置隔 电压互感器可合离用开一关组,以便断路器检 . 隔离开关。 修时隔离电源。
隔离开关配置原则2
~14 回时,母线宜单分段,进、出线回
路数≥15 回时,母线宜双分段。

各种变电站电气主接线图

各种变电站电气主接线图

各种变电站电气主接线图?TYD-110/ -0.07H3GW4-110DW/630左接地GW4-110DW/630双接地6-110LCWB100/5 0.2/0.5/10P/10PLW25-1261250A~40kAGW4-110DW/630左接地LGJ-120LRD-60-B 50/5GW4-110DW/630SF9-20000/110GW13-60G/400双接地Y,d11121?3×2.5%/6.3kVUk%=10.5%JDCF-110Y1W-73/15110 0.1 0.1 0.1???333 TMY-100X8Y5W1-100/260LFZJ-102000/5 0.5/0.5/10kV外来电源10/10PZN21-10/2500JYN2-10-03配CD10?TMY-100X8ZR-YJV22-10/3×50ZN21-10/630ZN21-10/1250ZN21-10/630RN2-6/0.5ARN2-10/0.5A配CD10?配CD10?配CD10?HY5WZ-10/30HY5WZ-17/51LZZBJ-10LZZBJ-10LZZBJ-10JDZJ-6JDZJ-10JYN2-10-20JYN2-10-19100/5 1000/5 100/5 JYN2-10-03 6 0.10.110/0.1kVJYN2-10-06(改)30.5/10P0.5/10P0.5/10P??33励磁互感器JYN2-10-03,改,,厂家配套,ZR-YJV22-6/3×50ZR-YJV22-10/3×50同RN2-6/0.5ASC9-800/6.3SC9-800/10D,yn11D,yn116 0.1 RN2-6/0.5AJDJ-6 ??JYN2-10-17336.3?5%/0.4kV10?5%/0.4kV左Ud%=7Ud%=7励磁变,厂家配套,JDZJ-6LMZ1-0.5 1200/5LMZ1-0.5 1200/5 6 0.1 0.12×(ZR-YJV223??33-6/3×240)LMY100×8-40×8LMY100×8-40×8GSFWG8000-6/4950G2G1GUe=6.3kVDW15-1200~~DW15-1200DW15-1200Ie=916.45A0.4kVCOSφ=0.8LZX-10Q800/5 0.5/10P 图5-19 某水电站电气主接线全图JYN2-10-184 回6 回220kV2×120MVA2×60MVA至无功补偿装置35kV8回图5-20 地区变电所接线110kV35kV1T2T2×10MVA10kV4回4回图5-21 终端变电所接线GGGGGG~~~~~~(a)(b)GGGGG~~~~~(c)(d)图6-1 设两台厂变的厂用电源引接方式?段?段cdabBDACefijghklmn图6-2 厂用负荷供电回路图6-3见“主接线厂用电实例”图6.3KV10kVRN1-6/10APRWG1-10/100SC-80/66.3?5##1厂变2厂变S9-80/35%/0.4KV10.5?2×2.5Y,yn0%/0.4KVKYN-28-10-78Uk%=4.0Y,yn0Uk%=4.0VV22-3×50+1×25VV22-3×50+1×25 DT864-2,380/220V,3(6A)DT864-2,380/220V,3(6A)42L6-A,0,150A42L6-A,0,150A42L6-V,0,450V42L6-V,0,450V42L6-A,0,100A42L6-A,0,100A42L6-A,0,150A42L6-A,0,100A42L6-A,0,100AkwhkwhAAAAAAAAAAAAAAAAAAAAAVVAI段380/220VBCLMY-40×4BT9509至直流屏GGD1-361-101-36GGDGGD配电屏型号1-36(改)GGD1-36(改)GGD配电屏编号 1 2 3 4 5集水井水安装场主厂房照明 1#机 2#机厂内油处理前池副厂房照事故照明整流器一整流器二馈线名称吊车母线分段备用备用1#厂变进线2#厂变进线备用生活区备用备用气系统备用泵动力箱动力箱分电箱室分电箱明分电箱分电箱动力盘动力盘动力箱回路电流,A, 25 23.6 34 11 281331.75725115115 1110.82710 28HD13BX-HD13BX-刀开关HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31200/31200/31DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DW15-DW15-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-断路器DW15-200/120A100/32A100/32A100/20A100/20A100/20A100/40A100/32A100/20A100/63A1 00/20A100/32A200/120A200/120A100/20A100/20A100/32A100/20A100/20A100/32A1 00/20A100/32A100/32ALMZ1-0.66,LMZ1-0.66,电流互感器LMZ1-0.66,100/5LMZ1-0.66,100/5LMZ1-0.66,100/5LMZ1-0.66,100/5LMZ1-0.66,100/5150/5150/5VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1VV22-1 VV22-1VV22-1引出电缆型号截面VV22-1-4×63×25+1×103×4+1×2.5-2×43×6+1×43×6+1×43×50+1×253×6+1×43×4+1×2.53×6+1×43×44×63×6+1×43×50+1×253×10+1×63×4+1×2.5 G25 穿管管径 G25 G25 G25 G25 G25 G15 G32 G32 G25 G25 G25 G25 G32说明: BT95O9为事故照明切换板~其直流电源用VV22-1-2×4电缆引至直流屏。

电站变电所电气主接线图(含说明)

电站变电所电气主接线图(含说明)
220kV I母220kV II母110kV套管CT:3(TMY-125X10)HY5WZ-17/45W110kV中性点设备:YH1.5W-72/186WLJW1-10W,400/1AGW13-63W/630LRB-110,200,400,600/1A,(两只)LRB-60,200,400,600/1A,(两只)LR-110,1200,1800,2400/1A,(一组)LRB-110,1200,1800,2400/1A,(两组)GW13-110W/630ALJW1-10W,200/1AYH1.5W-144/320W220kV中性点设备:110kV中性点套管CT:220kV中性点套管CT:2xLGJX-500/45YH10W-108/281WYH10W-204/532WLRB-220,800,1200,1600/1A,(两组)LR-220,800,1200,1600/1A,(一组)Uk1-2=14% Uk1-3=50% Uk2-3=35%220%%P8X1.5%/115/10.5kV#1主变压器容量比:180/180/90 接线组别:YN,Yno,dll220kV套管CT:SFSZ9-K-180000/2200.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2x600/1A2500A,50kA5P30/5P30电流互感器GW7-220IID(W)5P30/5P30/5P30C备用一BA出线二BCLGJX-630/55A#1主变间隔C备用三变主2xLGJX-500/45YH10W-108/281WYH10W-204/532W#2主变压器#1同(预留)#3主变压器(预留)#4主变压器#3主变间隔#2主变间隔#4主变间隔备用四CBABALDRE-130/116LDRE-130/116变主#1同隔间母联2x(LGJX-630/55)5P30/5P30/5P305P30/5P30/0.52x1200/1A电流互感器弹簧机构4000A,50kA断路器GW16-220D(W)2500A,50kA氧化锌避雷器LGJX-400/352500A,50kAGW16-220D(W)YH10W-204/532WTYD-220/ 3-0.0075H电压互感器(三相)220/ 3:0.1/ 3:0.1/ 3:0.1/ 3:0.1一同出线出线一BCA5P30/5P30/5P300.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2500A,50kA5P30/5P302x1200/1A电流互感器GW7-220IID(W)B、C相:OWF-220/ 3-0.005HA相:TYD-220/ 3-0.005HXZK-1600-1.0/40XZK-1600-0.5/402x(LGJX-400/35) I母母线设备II母母线设备设母同 I母线备SC11-400/11LGJX-300/40LDRE-130/116LDRE-130/1162000A,40kAGW4-126IID(W)GW16-126(W)GW16-126D(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P302x400/1A电流互感器3150A,40kA弹簧机构TYD-110/ 3-0.01H断路器A相:ACBCBA出线二出线一#1主变一出同线一出同线一同出线TBB22-10-100205组/334M-2BLXGN2B-12(Z)XHDCB-500/11DKSC-500/11 500kVA,ZN#1接地变10kV I段 3(TMY-125X10)XGN2B-12(Z)XGN2B-12(Z)#1母设10回#1站用变XGN2B-12(Z)ABCBAC出线三出线四#2主变同一出同线变#1主CBA#3母设#4母设10kV IV段10kV III段#3接地变#4接地变母联 Ⅱ母母线设备 Ⅲ母母线设备110kV Ⅰ母110kV Ⅳ母110kV Ⅱ母110kV Ⅲ母分段10回TBB22-10-100205组/334M-2BLTBB22-10-80165组/334M-2BL Ⅳ母母线设备 Ⅰ母母线设备2000A,40kALGJX-240/30TYD-110/ 3-0.02HYH10W-108/281W0.1/ 3:0.1/ 3:0.1220/ 3:0.1/ 3:GW4-126D(W)设母同 I母线备2000A,40kAGW16-126D(W)断路器3150A,40kA5P30/0.5/0.2S5P30/5P302xLGJX-500/45弹簧机构2x600/1A电流互感器母联CBACBA出线五#3主变ABC出线六一同出线断路器2xLGJX-500/453150A,40kAGW4-126IID(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P30弹簧机构2x600/1A电流互感器2000A,40kAGW16-126D(W)GW16-126(W)备用 CBA#4主变备用 CBA备用 CBA出线七CBA备用4回一同出线图中实线设备为本期建设部分,虚线设备为预留扩建部分。说 明:3(TMY-125X10)YH10W-108/281W10kV IIA段 3(TMY-125X10)线5回馈母同I#2A母设设母同#1#2接地变器同I母电容#2站用变变#1同接地变站同#1TBB22-10-100203组/334M-2BLTBB22-10-100202组/334M-2BL10kV IIB段 3(TMY-125X10)器同I母电容5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台LZZBJ9-10Q,400~600~800/15P20/0.5/0.2S 15VA, 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只LZZBJ9-10Q,800/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)ZR-YJV22-8.7/15-1*400GN30-10D/1250A,31.5kA,1组10/√3:0.1/√3:0.1/√3:0.1kV0.2/0.5/3P 30/40/150VA HY5WZ-17/45 1组LZZBJ9-10Q,150/1 ,5P20பைடு நூலகம்0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)LZZBJ9-10Q,150/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)XGN2B-12(Z)ZN28-4000-50kAGN30-10/4000A, 1台50kA,1组ZR-YJV22-8.7/15-3*240ZR-YJV22-8.7/15-3*240XGN2B-12(Z)5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台#2B母设设母同#1线5回馈母同IJW6-252W/630AJW6-252W/630A电流互感器2x600/1A5P30/5P305P30/0.5/0.2S断路器,弹簧机构3150A,40kAGW4-126D(W)2000A,40kAGW4-126D(W)2000A,40kA11%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11SC11-400/1111%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11设母同 I母线备设母同 I母线备母同 I母联C备用二BA2006.04.25例比APPROVED BY审 定AUDITED BY核 定设 计DESIGNED BYCHECKED BY校 核NO图 名图号TITLEPROJECT工程名施工时间TIME审 核AUDITED BY设计阶段220kV XX变电站 工程电气主接线图专业会签日期专业会签日期QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

35kV变电站主接线及总平面图

35kV变电站主接线及总平面图
电气主接线图馈电4回1#电容器(1000kvar)馈电4回1#站用变1#主变V5#母线35kV4#母线GW5-35IIW1000A 20kALRD-35300~600/120VALW8-351600A.25kALR-35 0.5S300~600/1GW5-35IIDW1000A 20kA同左3110P20/10P2032345LW8-351600A.25kALRD-3510P20300~600/120VAGW5-35IIW1000A 20kA300~600/120VAGW5-35IIW1000A 20kAGW5-35IIW1000A 20kARW10-35/0.5A35 0.10.1JDX6-35HY5WZ-51/1223 3 3同左SZ9-6300/3535+3X2.5%/10.5Ud=7.5%Y.d11本期容量同左LZZBJ9-10600/5A15VA.10P1515VA.0.5SVB21600A40kA左同LZZBJ9-1015VA.0.5S10VA.10P1525kA1600AVB2kV3 3 310 0.1JDZX9-10HY5WZ-17/43.50.1kVXRNP1-12/0.5A左同备用馈电2回左同备用馈电2回2#站用变10P20/0.5s20VACWC-24/3150600/5A31.5kA.4S100/5A.10P10ZRC-YJY22-8.7/15SC9-100/10.5TY-LJK120JUd=4%Dyn11-3X120mmLZZBJ9-1025kA10VA.10P15JNH1-1215VA.0.5S600/5A630AVB210.5+2X2.5%/0.4kV25kA.4S100/5A.10P10 1VAZRC-YJY22-8.7/15kVTY-LJK120J-3X120mm225kA10VA.10P15400/5ALZZBJ9-1015VA.0.5SJN15-10630AVB231.5kA.4S-3X120mm100/5A.10P10 1VAZRC-YJY22-8.7/15TY-LJK120J25kA10VA.10P15JNH1-1215VA.0.5S600/5ALZZBJ9-10630AVB22452#电容器(1000kvar)10P20LRD-3515VA.10P1510VA.10P1531.5kA.4S10.5+2X2.5%/0.4kVDyn11Ud=4%ZRC-YJY22-8.7/15-3X120mmSC9-100/10.5100/5A.10P10TY-LJK120J25kA10VA.10P15JNH1-1215VA.0.5S600/5ALZZBJ9-10630AVB2ZRC-YJY22-8.7/15kV100/5A.10P10 1VATY-LJK120J-3X120mm210VA.10P15JN15-1015VA.0.5SLZZBJ9-1025kA.4S400/5AVB2630A25kA-3X120mmZRC-YJY22-8.7/15100/5A.10P10 1VATY-LJK120J25kA10VA.10P15600/5A31.5kA.4SJNH1-12LZZBJ9-1015VA.0.5SVB2630AFEDCBAFEDACB1234567812435687电气总平面布置图2#变主控室外墙中心线主变中心线主变架构中心线道路中心线35kV架构中心线围墙中心线围墙中心线35kV架构中心线35kV架构中心线道路中心线主控室1# 30m2# 30m化粪池值班室休息室厨房厕所警卫室电容器室10kV开关室1234567891011121314151617CBAABCCBACBACBACBA1821201918171615%%p0.00-0.4501#变cbacabF1527F152720192221165048001200650038006360}6600}3600}1000}消防泵房深井泵房1150}1550}2700}1400240080203500}3500}765432189101112131410006001500600600F152712016001# 2# ACBACB16001650160017005400122005000720050001100020700500174051805200080005000720050003800176003300330033003300100050012005900800071055x5000=25000道路中心线3640}3895}60003500}CBAbacCBAbac1# 2# FEDCBAFEDACB1234567812435687650038600{\f宋体|b0|i0|c134|p5430007000{\f宋体|b0|i0|c134|p54{\f宋体|b0|i0|c134|p548120{\f宋体|b0|i0|c134|p547x800=560035001200322080002100R7000{\f宋体|b0|i0|c134|p5435001200120012001200编辑部:ivpinfo@本图纸由浩辰ICAD软件提供技术支持网易 电气 中国电气行业网络家园;因为专业,所以完美网易 NETEASE ==R7000QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

(完整word版)变电站电气主接线图

(完整word版)变电站电气主接线图

第五章图形L1 L2 L3 L4QS LQFQS BWBL1 L2Ⅰ段电源Ⅰ 电源Ⅱ电源Ⅰ图5-1 不分段的单母线接线第5、6 章图形WB电源Ⅱ图5-2 单母线分段接线L4QS LQFQS B Ⅱ段WBa1QSa1QF QFaWBQSa 1WBaQSa 2WBⅠ段 WB Ⅱ段电源Ⅰ 电源Ⅱ 图5-3 单母线带旁路母线接线QFd电源Ⅰ 电源Ⅱ图5-4 单母线分段带旁路母线接线图5-5 分段断路器兼作旁路断路器接线 图5-6 旁路断路器兼作分段断路器接线L1 L2QS 1 QS 2QSa 1WBaQSa 2QS 41QFQFa2QFL2L1 QS 5QS 3Ⅱ段Ⅰ段QS 1WBWBQS 2 电源Ⅰ电源Ⅱ电源Ⅰ 电源ⅡL1L2L3Ⅱ段 Ⅰ段 1QF QFjQS j Ⅱ QS j Ⅰ2QF电源Ⅰ 电源Ⅱ 图5-7 双母线接线L2WBL3L4L1 L2 L3WBⅡ段 Ⅰ段 QS 1QS Ⅱ1QS Ⅰ1QF QF电源Ⅰ 2QF电源Ⅱ图5-8 用母联断路器代替出线断路器时电流的路径L1QFj1 图5-9 双母线分段接线L1 L2 L3WBaQFaL1L2Ⅱ段Ⅰ段WBL3电源Ⅰ电源Ⅱ(a)图5-10 双母线带旁路接线(a)标准接线电源Ⅱ(b)图5-10 双母线带旁路接线b)母联断路器兼作旁路断路器接线(一)(c)图 5-10 双母线带旁路接线(c) 母联断路器兼作旁路断路器(二)L1 L2 L3WBa QSa QFjQS j ⅡS j ⅠⅡ段 Ⅰ段WBL1 L2 L2电源Ⅰ电源Ⅱ电源Ⅰ电源Ⅱ图5-11 一台半断路器接线L1 L2L1 L2 1QF 2QFQS13QFQS21QF3QF2QF1T2T1T2T(a)(b)图5-12 桥形接线(a) 内桥接线;(b) 外桥接线(a) 发电机-变压器单元 (b)发电机-三绕组变压器单元 (c)发电机-自耦变压器单元G(a)(b)图5-13 单元接线图5-14 扩大单元接线WLG G(a)(a) (b)图5-16 多角形接线图5-15 发电机-变压器-线路单元接线(a) 四角形接线 (b) 三角形接线(b)图5-17 例5-1 方案接线图( a )方案5-1-1 接线,( b )方案5-1-2 接线4MVA 2MVA6.3KV近区负荷 10KVG1G3×3.2MW(b)近区负荷6.3KVG(a)图5-18 例5-2 方案接线图a)方案5-2-1 接线,( b)方案5-2-2 接线,( c)方案5-2-3 接线注:图5-19 见:“主接线厂用电实例”图(b)(c)TMY-100X8ZN21-10/1250配CD10Ⅲ-30 -01LZZBJ-10 1000/50.5/10P励磁互感器(厂家配套)RN2-6/0.5A2NDJ-6√3励磁变(厂家配套)2×(ZR-YJV 22-6/3 ×240) SFWG8000-6/4950Ue=6.3kVIe=916.45ACOSφ=0.8LZX-10Q800/5 0.5/10P TYD-110/ √ -30.07HGW4-110DW/630 左接地GW4-110DW/630 双接地LCWB6-110100/50.2/0.5/10P/10PLW25-1261250A,40kAGW4-110DW/630左接地LGJ-120SF9-20000/110Y,d11121±3×2.5 %/6.3kVU k%=10.5%LFZJ-10000/5.5/0.5/0/10PZN21-10/2500配CD10ⅢTMY-100X8GW4-110DW/630双接地JDCF-110110 0.1 0.1 √3√3√30.1Y5W1-100/26030J2YN图5-19 某水电站电气主接线全图ZN21-10/630配CD10ⅢLZZBJ-10100/50.5/10PZR-YJV22-6/3 ×50SC9-800/6.3D,yn116.3 ±5%/0.4kVUd%=7LMZ1-0.5 1200/5LMY10×0 8-40×8DW15-1200ZN21-10/630配CD10ⅢLZZBJ-10100/50.5/10PZR-YJV22-10/3 ×5010kV外来电源LMZ1-0.5 1200/5LMY100×8-40×8ZR-YJV22-10/3 ×50SC9-800/10D,yn1110±5%/0.4kVUd%=70.4kVDW15-12004 回图5-20 地区变电所接线第六章图形b)a)图6-1 设两台厂变的厂用电源引接方式图6-2 厂用负荷供电回路图6-3 见“主接线厂用电实例”图6.3KVRN1-6/10ASC-80/66.3±51#厂变1厂变%/0.4KVY,yn0Uk%=4.0V22-3×50+1×25PRWG1-10/100S9-80/3510.5±2×2.5%/0.4KVY,yn0Uk%=4.010kVVV22-3×50+1×25AA A AAAV kwhLMY-40×4DT864-2,380/220V,3(6A42L6-A,0 ~150A42L6-A,0 ~150A 42L6-V,0 ~450VA I 段380/220VB C42L6-A,0 ~100AAAA42L6-A,0 ~100AA A A42L6-A,0 ~100AAAA(6A)42L6-A,0 ~150A42L6-V,0 ~450VAAAV kwh42L6-A,0 ~100AAAA配电屏型号GGD1 -36GGD1-36(改)GGD1-10GGD1-36(改)GGD1-36配电屏编号12345馈线名称集泵水井水动力箱吊车整流器一安动装场力箱备用事分故照明电箱主厂房照明分电箱生活区备用1#机动力盘1#厂变进线母线分段2#厂变进线2# 机动力盘备用备用整流器二厂内油处理室分电箱前池动力箱气系统备用副厂房照明分电箱备用回路电流(A)23.63411281331.75725115115251110.8271028刀开关HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31HD13BX-200/31断路器1D Z20J- D Z20J-D Z20J-DZ20J- D Z20J-DZ20J-DZ20J- D Z20J-DZ20J-DZ20J-DW15-DW15-200/120A DW15-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-DZ20J-00/32A 100/40A00/20A 100/32A 100/20A 100/20A100/32A 100/63A100/20A100/32A200/120A200/120A100/32A100/32A100/20A100/20A100/20A100/32A100/20A100/20A100/32A100/20A电流互感器LMZ1-0.66,100/5LMZ1-0.66,100/5LMZ1-0.66,150/5LMZ1-0.66,100/5LMZ1-0.66,150/5LMZ1-0.66,100/5LMZ1-0.66,100/5引出电缆型号截面3V×6+1×43×10+1×6VV3×22-14+1×2.53×6+1×4V-2×4V22-1-4×6 V3×25+1×103×6+1×4VV22-13×50+1×253×50+1×253×6+1×43×4+1×2.53×4+1×2.5 3×6+1×43×44×6穿管管径G25G25G25G25G15G32G32G25G25G25G25G25G25G32说明:BT95O9 为事故照明切换板,其直流电源用VV22-1-2 ×4电缆引至直流屏。

《变电所主接线》课件

《变电所主接线》课件
线路退出操作
当需要将线路由运行状态转为停用状态时,操作人员需核对现场设备状态,按 照调度指令进行操作,将线路由运行状态转为热备用状态,最后转为停用状态 。
变压器的投入与退
变压器投入操作
在确认变压器检修工作已结束,且满足送电条件后,调度会下令进行变压器的投 入操作。操作人员需核对现场设备状态,按照调度指令进行操作,将变压器由冷 备用状态转为运行状态。
测试设备功能
对已接线的设备进行功能测试,确保 其正常运行且无安全隐患。
清理工作现场
确保工作现场整洁,无杂物,为下一 次工作做好准备。
记录与归档
将操作过程、检查结果等信息详细记 录并归档,以便日后查阅和追溯。
主接线应具备灵活的扩 建和运行方式调整能力
,便于维护和管理。
经济性
主接线应优化设备选型 和投资成本,降低运行
和维护费用。
环保性
主接线应符合国家和地 方环保要求,减少对环
境的影响。
02 主接线的形式
单母线接线
定义
单母线接线是一种简单的 接线方式,它将所有电源 和出线都连接到一个母线 上。
特点
结构简单,成本低,便于 扩建。但可靠性较低,因 为整个系统依赖于单一的 母线。
变压器退出操作
当需要将变压器由运行状态转为停用状态时,操作人员需核对现场设备状态,按 照调度指令进行操作,将变压器由运行状态转为热备用状态,最后转为停用状态 。
母线的操作
母线充电操作
在进行母线充电时,应先检查母线保护装置是否正常,然后核对现场设备状态,按照调度指令进行操作,对母线 进行充电。
母线停役和送电操作
适用场景
适用于出线回路较少,对 供电可靠性要求不高的中 小型发电厂或变电所。

一文看懂全部变电站电气主接线方式.ppt

一文看懂全部变电站电气主接线方式.ppt

欢迎关注电气读书公众号
四 变电站电气主接线
南网110KV典型电气主接线见附件一 南网220KV典型电气主接线见附件二 南网500KV典型电气主接线见附件三 加纳330KV电气主接线见附件四
欢迎关注电气读书公众号
四 变电站电气主接线
1. 35~110kV主接线设计 2. 35~220kV主接线设计 3. 220~500kV主接线设计
这种接线不仅可靠性、灵活性都较高,而 且布置上也较方便(变压器进串的接线、 布置上较方便)。
欢迎关注电气读书公众号
A
A
图1-8 变压器母线接线
欢迎关注电气读书公众号
三 高压配电装置基本接线
11. 4/3断路器接线
这是由3/2断路器接线演变来的接线方式, 即在3/2断路器接线的串内再串入一台断路 器,就可再引出一个元件,形成4台断路器 接3个元件的接线方式。
欢迎关注电气读书公众号
三 高压配电装置基本接线
1. 变压器—线路组接线
变压器—线路组接线是一台变压器与一条 线路构成一个接线单元。
欢迎关注电气读书公众号
线路
线路
(a)
(b)
欢迎关注电气读书公众号
欢迎关注电气读书公众号
优点:设备少、高压配电装置简单、 占地面积小、本回路故障对其他回路 没有影响。
1. 35~110kV主接线设计
主接线回路宜采用无油断路器,市区和地下 变电站可采用GIS。配电装置易于检修、操作 的开关柜,不宜设置旁路设施。
母线上避雷器和电压互感器可合用一组隔离 开关,变压器引出线上的避雷器不宜装设隔 离开关。
欢迎关注电气读书公众号
2. 35~220kV主接线设计
减少电压等级,简化接线。 线路3回及以下、主变为3台及以下终端变电站

变电站主接线图(解释)

变电站主接线图(解释)

变电站一次系统图1、单母线接线特点:只有一组母线,所有电源回路和出线回路,均经过必要的开关电器连接到该母线上并列运行。

主要优点:接线简单、清晰,所用电气设备少,操作方便,配电装置造价便宜。

主要缺点:适应性差,母线故障或检修,全部回路均需停电;任一回路断路器检修,该回路停电。

适用范围:单电源的发电厂和变电所,且出线回路数少,用户对供电可靠性要求不高的场合;10kV纯无功补偿设备出线(电容器、电抗器)。

2、单母线分段接线特点:与单母线接线方法相比,增加了分段断路器,将母线适当分段。

当对可靠性要求不高时,也可利用分段隔离开关进行分段。

母线分段的数目,决定于电源的数目,容量、出线回数,运行要求等。

母线分段一般分为2-3段。

优点:母线发生故障时,仅故障母线段停电,缩小停电范围;对重要用户由两侧共同供电,提高供电可靠性;缺点:当一段母线故障或检修时,与该段所连的所有电源和出线均需断开,单回供电用户要停电;任一出线断路器检修,该回路要停电。

适用:6~10kV,出线6回以上;35~66kV,出线不超过8回时;110~220kV,出线不超过4回时。

3、单母线分段带旁路母线接线优点:增设旁路母线,增设各出线回路中相应的旁路隔离开关,解决出线断路器检修时的停电问题。

为了节省投资,可不专设旁路断路器,而用母线分段断路器兼作旁路断路器。

因为电压越高,断路器检修所需的时间越长,停电损失越大,因此旁路母线多用于35kV以上接线。

适用:6~10kV接线一般不设旁路母线;35~66kV,可设不专设旁路断路器的旁路母线;110kV出线6回以上,220 kV出线4回以上,宜用专设旁路断路器的旁路母线;出线断路器使用可靠性较高的SF6断路器时,可不设旁路母线。

4、双母线接线优点:两条母线互为备用,一条母线检修时,另一条母线可以继续工作,不会中断对用户的供电;任一母线侧隔离开关检修时,只需断开这一回路即可;工作母线故障时,所有回路能迅速切换至备用母线而恢复供电;可将个别回路单独接在备用母线上进行特殊工作或试验;因而可靠性高,运行方式灵活,便于扩建。

变电站电气主接线图.

变电站电气主接线图.

2×8MW(a)2×10MVA1G G1TG2G2T110KV 35KV2×8MW(b)20MVAG1G 2GG110KV2T2G(c)2×8MW2×10MVAG1G 1T G35KV图5-18 例5-2方案接线图(a )方案5-2-1接线,(b)方案5-2-2接线,(c)方案5-2-3接线注:图5-19见:“主接线厂用电实例”图TMY-100X8ZN21-10/1250配CD10ⅢLZZBJ-101000/5 0.5/10P 2×(ZR-YJV 22-6/3×240)RN2-6/0.5ASFWG8000-6/4950Ue=6.3kV Ie=916.45A COSφ=0.8LZX-10Q800/5 0.5/10PJ Y N 2-10-03(改)1G励磁变(厂家配套)励磁互感器(厂家配套)JDJ-6 36 0.1√3√J Y N 2-10-17J Y N 2-10-18RN2-6/0.5A 36 0.1 0.1JDZJ-63√√3J Y N 2-10-20√ 6 0.1 0.1√333JDZJ-6RN2-6/0.5AHY5WZ-10/302G同左ZN21-10/2500配CD10ⅢLFZJ-102000/5 0.5/0.5/10/10PJ Y N 2-10-03SF9-20000/110Y,d11121±3×2.5%/6.3kV U k %=10.5%LGJ-120GW4-110DW/630左接地LW25-1261250A,40kA GW4-110DW/630双接地LCWB 6-110100/50.2/0.5/10P/10PTYD-110/ -0.07H 3√LRD-60-B 50/5GW4-110DW/630双接地JDCF-110Y5W1-100/260√110 0.1 0.13√√33GW 13-60G/400Y1W-73/15ZN21-10/630配CD10ⅢLZZBJ-10100/5 0.5/10PJ Y N 2-10-03ZR-YJV 22-6/3×50SC9-800/6.3D,yn116.3±5%/0.4kV Ud%=7LMZ1-0.5 1200/5LMZ1-0.5 1200/5SC9-800/10D,yn1110±5%/0.4kV Ud%=7ZR-YJV 22-10/3×50LZZBJ-10100/5 0.5/10PZN21-10/630配CD10ⅢJ Y N 2-10-06(改)ZR-YJV 22-10/3×5010kV外来电源J Y N 2-10-19JDZJ-10HY5WZ-17/51RN2-10/0.5A10/0.1kV0.4kVLMY100×8-40×8DW15-1200DW15-1200DW15-12000.1LMY100×8-40×8G~G~TMY-100X8GW4-110DW/630左接地图5-19 某水电站电气主接线全图图5-20 地区变电所接线8回35kV220kV4 回2×120MVA至无功补偿装置6 回2×60MVA4回2×10MVA1T图5-21 终端变电所接线4回10kV2T110kV 35kVVV22-13×50+1×251#厂变进线V 42L6-A,0~150A DT864-2,380/220V,3(6A)42L6-V,0~450V说明:BT95O9为事故照明切换板,其直流电源用VV22-1-2×4电缆引至直流屏。

变电站主接线图(解释)

变电站主接线图(解释)

变电站主接线图(解释)变电站一次系统图1、单母线接线特点:只有一组母线,所有电源回路和出线回路,均经过必要的开关电器连接到该母线上并列运行。

主要优点:接线简单、清晰,所用电气设备少,操作方便,配电装置造价便宜。

主要缺点:适应性差,母线故障或检修,全部回路均需停电;任一回路断路器检修,该回路停电。

适用范围:单电源的发电厂和变电所,且出线回路数少,用户对供电可靠性要求不高的场合;10kV纯无功补偿设备出线(电容器、电抗器)。

2、单母线分段接线特点:与单母线接线方法相比,增加了分段断路器,将母线适当分段。

当对可靠性要求不高时,也可利用分段隔离开关进行分段。

母线分段的数目,决定于电源的数目,容量、出线回数,运行要求等。

母线分段一般分为2-3段。

优点:母线发生故障时,仅故障母线段停电,缩小停电范围;对重要用户由两侧共同供电,提高供电可靠性;缺点:当一段母线故障或检修时,与该段所连的所有电源和出线均需断开,单回供电用户要停电;任一出线断路器检修,该回路要停电。

适用:6~10kV,出线6回以上;35~66kV,出线不超过8回时;110~220kV,出线不超过4回时。

3、单母线分段带旁路母线接线优点:增设旁路母线,增设各出线回路中相应的旁路隔离开关,解决出线断路器检修时的停电问题。

为了节省投资,可不专设旁路断路器,而用母线分段断路器兼作旁路断路器。

因为电压越高,断路器检修所需的时间越长,停电损失越大,因此旁路母线多用于35kV以上接线。

适用:6~10kV接线一般不设旁路母线;35~66kV,可设不专设旁路断路器的旁路母线;110kV出线6回以上,220 kV出线4回以上,宜用专设旁路断路器的旁路母线;出线断路器使用可靠性较高的SF6断路器时,可不设旁路母线。

4、双母线接线优点:两条母线互为备用,一条母线检修时,另一条母线可以继续工作,不会中断对用户的供电;任一母线侧隔离开关检修时,只需断开这一回路即可;工作母线故障时,所有回路能迅速切换至备用母线而恢复供电;可将个别回路单独接在备用母线上进行特殊工作或试验;因而可靠性高,运行方式灵活,便于扩建。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档