airtac电磁阀valve说明书

合集下载

Air Operated Valve 产品说明书

Air Operated Valve 产品说明书

Doc. No.SYJ300-OMO0002-AAir Operated ValveSYJA300 / SYJ3000 SeriesSafety Instructions ---------------------------------------------------------------------------- 2,3 Precautions on Design ---------------------------------------------------------------------- 4 Selection ---------------------------------------------------------------------------------------- 4 Mounting ---------------------------------------------------------------------------------------- 4 Piping -------------------------------------------------------------------------------------------- 5 Lubrication -------------------------------------------------------------------------------------- 5 Air Supply --------------------------------------------------------------------------------------- 5,6 Operating Environment ---------------------------------------------------------------------- 6 Maintenance ------------------------------------------------------------------------------------ 6 Trouble shooting ------------------------------------------------------------------------------- 7,8SafetyThese safety instructions are intende These instructions indicate the level They are all important notes s (ISO/IEC)*1), and other safety regulat *1) ISO 4414: Pneumatic fluid power -- Ge ISO 4413: Hydraulic fluid power -- Gen IEC 60204-1: Safety of machinery -- ISO 10218-1992: Manipulating industria etc.Caution Cautionin minor or Warning Warning result in dea DangerDangerin death or1. The compatibility of the product decides its specifications.Since the product specified here is equipment must be decided by the p necessary analysis and test results.The expected performance and safe has determined its compatibility with This person should also continuou information, with a view to giving due equipment.2. Only personnel with appropriate The product specified here may bec The assembly, operation and mai performed by an operator who is app3. Do not service or attempt to rem 1.The inspection and maintenance o prevent falling or runaway of the d 2.When the product is to be remove and the power from any appropria of all relevant products carefully.3. Before machinery/equipment is re4. Contact SMC beforehand and ta be used in any of the following c 1. Conditions and environments outs direct sunlight.2. Installation on equipment in conju vehicles, military, medical treatme beverages, emergency stop circui other applications unsuitable for th3. An application which could have n analysis.e in an interlock circuit, whichmechanical protective function, an Safety Instructionstended to prevent hazardous situations and/or equip evel of potential hazard with the labels of “Caution,”for safety and must be followed in addition gulations.General rules relating to systems. General rules relating to systems. Electrical equipment of machines .(Part 1: General requi dustrial robots -Safety. on indicates a hazard with a low level of risk which, if or or moderate injury. ing indicates a hazard with a medium level of risk whi death or serious injury.indicates a hazard with a high level of risk which, if or serious injury.Warning oduct is the responsibility of the person who des ere is used under various operating conditions, c the person who designs the equipment or decides its sults. d safety assurance of the equipment will be the respon y with the product. nuously review all specifications of the product refer g due consideration to any possibility of equipment fai priate training should operate machinery and eq y become unsafe if handled incorrectly. maintenance of machines or equipment including is appropriately trained and experienced.o remove product and machinery/equipment unt nce of machinery/equipment should only be performed the driven objects have been confirmed. moved, confirm that the safety measures as mentioned opriate source is cut, and read and understand the spe ully. t is restarted, take measures to prevent unexpected op and take special consideration of safety measur wing conditions.s outside of the given specifications, or use outdoors o conjunction with atomic energy, railways, air navigation atment, combustion and recreation, or equipment in c circuits, clutch and brake circuits in press applications for the standard specifications described in the produ ave negative effects on people, property, or animals re hich requires the provision of double interlock for po on, and periodical checks to confirm proper operation.equipment damage. tion,” “Warning” or “Danger.” n to International Standardsrequirements) ch, if not avoided, could resultk which, if not avoided, could ch, if not avoided, will resulto designs the equipment orits compatibility with specific des its specifications based on esponsibility of the person who referring to its latest catalog nt failure when configuring the d equipment.uding our products must be t until safety is confirmed.ormed after measures to ioned above are implemented e specific product precautions ed operation and malfunction.easures if the product is to oors or in a place exposed to gation, space, shipping, t in contact with food and tions, safety equipment or product catalog. als requiring special safety or possible failure by using a ation.Safe1.The product is provided for use The product herein described is ba If considering using the product in o or a contract if necessary.If anything is unclear, contact yourLimited warranty and D The product used is subject to Requirements”.Read and accept them before usingLimited warranty and Disc 1.The warranty period of the produ whichever is first.∗2)Also, the product may have spec consult your nearest sales branc2. For any failure or damage repora replacement product or neces This limited warranty applies on incurred due to the failure of the3. Prior to using SMC products, pl noted in the specified catalog fo∗2) Vacuum pads are excluded A vacuum pad is a consuma Also, even within the warran pad or failure due to the det warranty.Compliance Requirements 1. The use of SMC products with destruction (WMD) or any othe 2. The exports of SMC products relevant security laws and reg shipment of a SMC product to are known and followed. Safety InstructionsCaution use in manufacturing industries.is basically provided for peaceful use in manufactu ct in other industries, consult SMC beforehand and e your nearest sales branch. nd Disclaimer/Compliance Requi to the following “Limited warranty and Disclaim sing the product. Disclaimer product is 1 year in service or 1.5 years after the specified durability, running distance or replace branch. eported within the warranty period which is clea ecessary parts will be provided. es only to our product independently, and not to of the product. ts, please read and understand the warranty term og for the particular products. uded from this 1 year warranty. sumable part, so it is warranted for a year after it arranty period, the wear of a product due to the e deterioration of rubber material are not covere mentswith production equipment for the manufacture other weapon is strictly prohibited. ucts or technology from one country to anothe d regulations of the countries involved in the tra ct to another country, assure that all local rulesfacturing industries. and exchange specifications equirementsisclaimer” and “Complianceer the product is delivered,placement parts. Please s clearly our responsibility, ot to any other damage y terms and disclaimers fter it is delivered.o the use of the vacuum overed by the limited acture of weapons of massother are governed by the he transaction. Prior to the ules governing that export- 4 -Design / Selection1. Confirm the specifications Products represented designed only ( including vacuum).Do not operate beyond the range of specifications, as this can cause damage or malfunction.We do not guarantee against any damage if the product is used outside of the specification range.2. Actuator driveWhen an actuator, using a valve, take appropriate measures (coverinstallation or approach prohibition) to prevent potential danger caused by actuator operation.3. Effect of back manifold.1. Operation manual Install readingWarningWarning1. Refer to the Fittings and Tubing Precautions for handling one-touch fittings.2. Preparation before pipingBefore piping isblown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.3. Wrapping of pipe tapeWhen screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the piping.thread ridges exposed at the end of the threads4. Connection of fittingsWhen screwing fittings into valves, tighten as follows. 1. Lubrication1) The valve has been lubricated for life by the factory 1. Type of fluidsPleaseapplications other than compressed air.1. When extremely dry air is used as the fluid,propertiesCaution WarningWarningCaution- 5 -Air Supply4. If excessive carbon powder is seen, install a mist separator on the upstream side of the valve.If excessive carbon dust is generated by thecompressor, it may adhere to the inside of a valve and cause it to malfunction.For compressed air quality, refer to SMC’s BestPneumatics catalog.Operating Environment1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these .2. Do not use in an environment where flammable gas or explosive gas exists. The products do not have an explosion proof construction.3. Do not use in a place subject to heavy vibration and/or shock.4. The valve should not be exposed to prolonged sunlight. Use a protective cover.5. Remove any sources of excessive heat.6. If it is used in an environment where there is possible contact with oil, weld spatter, etc., exercise preventive measures.Maintenance1. Perform maintenance inspection according to the procedures indicated in the operation manual.If handled improperly, malfunction and damage of machinery or equipment may occur.2. Removal of equipment, andsupply/exhaust of compressed airWhen components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function.For 3-position closed center type, exhaust the residual pressure between the valve and the cylinder.When the equipment is operated after remounting or replacement, first confirm that measures are in place to prevent lurching of actuators, etc. Then, confirm that the equipment is operating normally.3. Low frequency operationValves should be operated at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.)4. Manual override operationWhen the manual override is operated, connected equipment will be actuated.Operate after safety is confirmed. 1. Drain flushingRemove drainage from the air filters regularly.2. LubricationIn the case of rubber seals, once lubrication has been started, it must be continued.Use class 1 turbine oil (with no additive), VG32 because if other lubricant oil is used, it may cause malfunction. Please contact SMC for suggested class2 turbine oil (with additive), VG32.Warning Warning CautionCaution SYJA300/3000 SeriesPrecautions for 5 Port Solenoid Valve ③Be sure to read before handling. Refer to main text for detailed precautions on every series.- 6 -TROUBLESHOOTINGRemedyShould any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.(Next page)③①②④①②⑤RemedyIf no improvement is achieved in spite of the above countermeasure, inside of the valve may have some failure. In this case, stop using the valve immediately.If any of followings are carried out, inside of the valve may have some failure. In this case, stop using the valve immediately.① Oil other than the specified one has been lubricated.② Lubrication has been stopped intermediately, or lubrication was suspended temporary.③ Strong impact was given.④ Alien substance such as drain and particle got into.⑤ Prohibited way of using the valve which is written at "Precautions" section in this operation manualwas carried out excluding above-mentioned.※If any trouble should happen with the uni,please send it back to the supplier for repair or replacement.A Added the SYJA3000 SS1st printing PP 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPANTel: + 81 3 5207 8249 Fax: +81 3 5298 5362© 2011 SMC Corporation All Rights Reserved。

电磁阀的使用说明

电磁阀的使用说明

电磁阀的使用说明选型要领:电磁阀选型首先应该依次遵循安全性,可靠性,适用性,经济性四大原则,其次是根据六个方面的现场工况(即管道参数、流体参数、压力参数、电气参数、动作方式、特殊要求进行选择)。

选型依据:一、根据管道参数选择电磁阀的:通径规格(即DN)、接口方式1、按照现场管道内径尺寸或流量要求来确定通径(DN)尺寸。

2、接口方式,一般>DN50要选择法兰接口,≤DN50则可根据用户需要自由选择。

二、根据流体参数选择电磁阀的:材质、温度组1、腐蚀性流体:宜选用耐腐蚀电磁阀和全不锈钢;食用超净流体:宜选用食品级不锈钢材质电磁阀。

2、高温流体:要选择采用耐高温的电工材料和密封材料制造的电磁阀,而且要选择活塞式结构类型的。

3、流体状态:大至有气态,液态或混合状态,特别是口径大于DN25订货时一定要区分开来。

4、流体粘度:通常在50cSt以下可任意选择,若超过此值,则要选用高粘度电磁阀。

三、根据压力参数选择电磁阀的:原理和结构品种1、公称压力:这个参数与其它通用阀门的含义是一样的,是根据管道公称压力来定。

2、工作压力:如果工作压力低则必须选用直动或分步直动式原理;最低工作压差在0.04Mpa以上时直动式、分步直动式、先导式均可选用。

四、电气选择:电压规格应尽量优先选用AC220V、DC24较为方便。

五、根据持续工作时间长短来选择:常闭、常开、或可持续通电1、当电磁阀需要长时间开启,并且持续的时间多余关闭的时间应选用常开型。

2、要是开启的时间短或开和关的时间不多时,则选常闭型。

3、但是有些用于安全保护的工况,如炉、窑火焰监测,则不能选常开的,应选可长期通电型。

六、根据环境要求选择辅助功能:防爆、止回、手动、防水雾、水淋、潜水1、爆炸性环境:必须选用相应防爆等级的电磁阀2、当管内流体有倒流现象时,可选择带止回功能电磁阀。

3、当需要对电磁阀进行现场人工操作时,可选择带手动功能电磁阀。

4、露天安装或粉尘多场合应选用防水,防尘品种(防护等级在IP54以上)。

大港区亚德客3V系列电磁阀产品简介

大港区亚德客3V系列电磁阀产品简介

大港区亚德客3V系列电磁阀产品简介大港区亚德客3V系列电磁阀产品简介亚德客SAIRIAE电磁阀电磁阀定义及原理电磁阀是用来控制流体的自动化基础元件,属于执行器;并不限于液压,气动。

电磁阀用于控制液压流动方向,工厂的机械装置般都由液压钢控制,所以就会用到电磁阀。

工作原理:电磁阀里有密闭的腔,在的不同位置开有通孔,每个孔都通向不同的油管,腔中间是阀,两面是两块电磁铁,哪面的磁铁线圈通电阀体就会被吸引到哪边,通过控制阀体的移动来档住或漏出不同的排油的孔,而进油孔是常开的,液压油就会进入不同的排油管,然后通过油的压力来推动油刚的活塞,活塞又带动活塞杆,活塞竿带动机械装置动。

这样通过控制电磁铁的电流就控制了机械运动。

分类:①直动式电磁阀原理:通电时,电磁线圈产生电磁力把关闭件从阀座上提起,阀门打开;断电时,电磁力消失,弹簧把关闭件压在阀座上,阀门关闭。

特点:在真空、负压、零压时能正常工作,但通径般不超过25mm。

②分布直动式电磁阀原理:它是种直动和先导式相结合的原理,当入口与出口没有压差时,通电后,电磁力直接把先导小阀和主阀关闭件依次向上提起,阀门打开。

当入口与出口达到启动压差时,通电后,电磁力先导小阀,主阀下腔压力上升,上腔压力下降,从而利用压差把主阀向上推开;断电时,先导阀利用弹簧力或介质压力推动关闭件,向下移动,使阀门关闭。

特点:在零压差或真空、高压时亦能可*动作,但功率较大,要求必须水平安装。

③先导式电磁阀原理:通电时,电磁力把先导孔打开,上腔室压力迅速下降,在关闭件周围形成上低下高的压差,流体压力推动关闭件向上移动,阀门打开;断电时,弹簧力把先导孔关闭,入口压力通过旁通孔迅速腔室在关阀件周围形成下低上高的压差,流体压力推动关闭件向下移动,关闭阀门。

亚德客3V电磁阀产品特点:1、先导方式:内部引导式或外部引导式可选;2、滑柱式结构,密封性好,反应灵敏;3、双头电磁阀具有记忆功能;4、内孔采用特殊加工工艺,磨擦阻力小,启动气压低,使用寿命长;5、无需加油润滑;6、附设手动装置,利于安装调试;7、有多种标准电压等可供选用;8、可与底座集成阀组,节省安装空间。

百灵气动AirTAC型气源处理件说明书

百灵气动AirTAC型气源处理件说明书

百灵气动AirTAC型气源处理件说明书一.使用条件(技术参数)气源处理件使用的系统压力,介质温度及调压范围应符合下表规定的数值:最高使用压力 1.0Mpa(10.2kgf/㎝2)环境及流体温度5~60建议用油透平1号油(ISOVG32)滤芯精度40u调压范围0.05~0.85Mpa(0.51~8.7kgf/㎝2)工作介质空气杯防护罩1000~2000无2500~6000有阀型带溢流型二.安装使用1.安装应注意清洗连接管道与接头,避免将脏物带入气路。

2.安装应注意气流方向与本体上的箭头方向一致,注意接管及牙型是否正确。

3.压力调节:将调压旋钮向上拉起,顺时针旋转,压力上升。

逆时针旋转,压力下降。

调整至所需压力,将调压旋钮按下呈锁紧状态.4.水分排出:无空气压力时,水分自动排出。

有空气压力时,将排水柱向上推,水分排出,排水完毕,将排水柱放开,排水柱自动弹下,排水结束。

当水位超过上限时,请及时排水,否则将造成除湿不良。

5.油量调整:旋转调油旋盖,将旋盖上数字对准▲箭头方向:数字0为油量最小,9为油量最大。

自9到0位置不能逆时针旋转,需顺时针旋转。

设定数字后,空气流量大,滴油量大,空气流量小,滴油量小。

(顺时针旋转针阀,滴油量减少;逆时针旋转针阀,滴油量增加。

空气量调整,设定针阀后空气流量大,滴油量大,空气流量小,滴油量小。

)6.加油方法;可以不关闭空气管路而进行加油作业,逆时针旋起加油螺丝,加油时加油量不用超过杯子80%.加完油后,将加油螺丝锁紧;不可直接将油杯卸下进行加油。

三.保养1。

清洗/更换滤网:取出滤网,用空气由内向外吹,即可以重复使用。

2.透明PC杯:卸下PC杯,用干净干布擦拭即可,不可使用任何会破坏PC杯材质的化学物品来清洗。

四.使用注意事项1.使用压力请勿超过1Mpa.2.禁止接近或在有机溶剂环境中使用3.给油雾器油杯中加油时,要关闭进入油雾器的压缩空气4.其他详细资料参产品样本五.定购代码示例1. AC------2000-------M↓↓↓型号接管口径排水方式AC:A系列三联件1500:PT1/8 空白:差压排水式AFC:A系列二联件2000:PT1/4 M:标准手排式2. AC2000-----------------01↓↓型号接管口径/螺纹(Rc)AC三联组合M5--M5AF过滤器01---1/8:Aw调压过滤器02---1/4AR调压阀03---3/8AL油雾器04---1/206---3/410---1。

电磁阀调试方法说明书

电磁阀调试方法说明书

电磁阀调试方法说明书一、概述电磁阀是一种常用于控制流体流动的设备,广泛应用于工业自动化系统中。

为了确保电磁阀能够正常运行,调试是必不可少的环节。

本说明书将详细介绍电磁阀的调试方法,以确保其安全可靠地工作。

二、准备工作在进行电磁阀调试之前,请确保已经具备以下准备工作:1. 获得电磁阀的产品说明书,了解其基本参数和工作原理;2. 检查电磁阀设备是否完好,包括外观、连接线路等;3. 准备调试设备,包括电源、仪器表等。

三、电磁阀调试步骤1. 连接电磁阀:根据产品说明书,将电磁阀与相关设备连接。

确保连接牢固、接口无松动。

2. 接通电源:将电磁阀连接至电源,确保电流符合产品额定电流要求。

注意安全操作,避免触电事故。

3. 检查控制信号:使用合适的控制信号源,向电磁阀提供控制信号。

可通过示波器、数字多用表等仪器检测信号波形和电压值,确保信号正常。

4. 观察工作状态:在控制信号输入的情况下,观察电磁阀的工作状态。

包括阀门开启与关闭的时间、动作是否迅速、声音是否正常等。

如发现异常情况,应立即停止调试,并检查原因。

5. 调整参数:根据需要,调整电磁阀的参数,如开启和关闭时间,以适应实际工作要求。

可参考产品说明书或咨询厂家获取相关参数设置建议。

6. 进行功能测试:利用合适的液体或气体介质,验证电磁阀的功能。

注意介质压力、温度等参数的合理范围,避免损坏电磁阀设备。

7. 记录调试结果:对于每次调试,记录相关参数、设备状态和测试结果。

以备日后参考和故障排查之用。

四、注意事项1. 安全第一:在进行电磁阀调试时,务必注意安全操作。

避免触电、烧伤等意外事故的发生。

2. 严格按照说明书操作:在调试过程中,应仔细阅读电磁阀的产品说明书,并按照要求进行操作。

3. 注意环境条件:调试时,应确保环境温度、湿度等条件符合产品要求,避免影响电磁阀的工作性能。

4. 小心存放和搬运:在调试结束后,应妥善存放电磁阀设备,避免损坏。

搬运时应轻拿轻放,避免碰撞。

.AIRTAC电磁阀

.AIRTAC电磁阀

AIRTAC电磁阀AIRTAC电磁阀隔磁套管内的铁芯完成,不存在动密封,所以外漏易堵绝。

电动阀力矩控制不易,容易产生内漏,甚至拉断阀杆头部;电磁阀的结构型式容易控制内泄漏,直至降为零。

所以,电磁阀使用特别安全,尤其适用于腐蚀性、有毒或高低温的介质。

AIRTAC电磁阀的用途电磁阀用于液体和气体管路的开关控制,是两位DO控制。

一般用于小型管道的控制。

电动阀用于液体、气体和风系统管道介质流量的模拟量调节,是AI控制。

在大型阀门和风系统的控制中也可以用电动阀做两位开关控制。

电磁阀只能用作开关量,是DO控制,只能用于小管道控制,常见于DN50及以下管道,往上就很少了。

电动阀可以有AI反馈信号,可以由DO或AO 控制,比较见于大管道和风阀等。

1.开关形式电磁阀通过线圈驱动,只能开或关,开关时动作时间短。

电动阀的驱动一般是用电机,开或关动作完成需要一定的时间模拟量的,可以做调节。

2.工作性质电磁阀一般流通系数很小,而且工作压力差很小。

比如一般25口径的电磁阀流通系数比15口径的电动球阀小很多 1AIRTAC电磁阀的主要特点(1)外漏堵绝,内漏易控,使用安全。

内外泄漏是危及安全的要素。

其它自控阀通常将阀杆伸出,由电动、气动、液动执行机构控制阀芯的转动或移动。

这都要解决长期动作阀杆动密封的外泄漏难题;唯有电磁阀是用电磁力作用于密封在电动调节阀隔磁套管内的铁芯完成,不存在动密封,所以外漏易堵绝。

电动阀力矩控制不易,容易产生内漏,甚至拉断阀杆头部;电磁阀的结构型式容易控制内泄漏,直至降为零。

所以,电磁阀使用特别安全,尤其适用于腐蚀性、有毒或高低温的介质。

(2)系统简单,便接电脑,价格低谦。

电磁阀本身结构简单,价格也低,比起调节阀等其它种类执行器易于安装维护。

更显著的是所组成的自控系统简单得多,价格要低得多。

由于电磁阀是开关信号控制,与工控计算机连接十分方便。

在当今电脑普及,价格大幅下降的时代,电磁阀的优势就更加明显。

AirTAC C-6DLK产品手册说明书

AirTAC C-6DLK产品手册说明书

AirTAC产品手册C-6DLKAirTAC | 机密目录注意事项 (2)关于使用 (3)1.外观 (6)2.一般规格 (7)3.电源/通信连接 (8)4.标牌和指示灯 (9)5.拨码说明 (10)6.输出端子定义 (11)7.参数设置 (12)8.调试环境 (13)9.总线 (19)AirTAC | 机密注意事项AirTAC | 机密关于使用AirTAC | 机密AirTAC | 机密AirTAC | 机密1.外观序号描述1 IO-Link连接器(端口B类)(M12 x 12 显示窗3 接地4 D-Sub输出AirTAC | 机密2.一般规格AirTAC | 机密3.电源/通信连接AirTAC | 机密4.标牌和指示灯状态描述灯灭未上电绿灯常亮通讯未建立绿灯闪烁通讯已建立绿灯常亮电压正常AirTAC | 机密5.拨码说明6.输出端子定义对插件接线图输出类型Source/PNP (-Common)点数24 点负载单片阀24V 1.5W输出V1供电电压和电流24VDC,24片阀最大输出电流2AAirTAC | 机密AirTAC | 机密7.参数设置7.1.参数定义和设置AirTAC | 机密7.3. 错误码8. 调试环境备注:1. IO-Link 设备的安装方式对组态软件有很强的依赖性。

请参阅您的IO-Link Master 的配置软件手册。

2. 本文中使用的PLC 为西门子PLC S7-1500和TIA Portal V15.1制作。

Master 为IFM AL1100。

AirTAC | 机密8.1.IODD文件安装配置阀岛需要一个设备描述文件IODD。

IODD文件是基于XML的文件,包含阀岛的通信特性、设备参数、标识数据、过程数据和诊断数据等所有信息。

将IODD文件和图标放在如下路径:C:\Program Files\ifm electronic\LR4\LRBackend.LRDevice\Lib\PlugInIodd\iodd8.2.IO-Link主机端口配置IO-Link主机端口子模块配置在启动阀岛之前,必须将性能分配给IO-Link主机的端口。

台湾亚德客电磁阀使用说明

台湾亚德客电磁阀使用说明

台湾【亚德客电磁阀】使用说明
1、使用前注意检查组件在运输过程中是否损坏,然后安装使用;
2、安装时请注意气体流动方向及接管牙型是否正确,使用介质必须经过40um
滤芯过滤;
3、请注意安装条件是否符合技术要求(如“电压”、“作动频率”、“工作压力”、
“使用温度范围”等),然后安装使用;
4、安装时注意气体流动方向,P为进气口,A(B)为工作口、R(S)为排气口;
5、尽量避免在震动的环境下使用,并注意低温下的防冻措施;
6、连接管路时,注意止泄带缠绕不可超过接头牙端面,注意清除管路接头内的
粉尘、铁屑等杂物,避免杂质或异物进入阀体内;
7、请注意防尘,建议排气口安装消声器或消声节流阀,拆下来不用时应在进、
出口装防尘套;
8、整机调试时,建议先用手动装置调试,然后在通电调试。

以上便是就台湾亚德客电磁阀安装使用进行的一系列说明,希望对您有所帮助!文章来自于济南元元利富科贸有限公司,如有需要欢迎拨打4006589919或者登录,我们将竭诚为您服务!。

airtac二位三通电磁阀怎样接线

airtac二位三通电磁阀怎样接线
airtac二位三通电磁阀怎样接线电磁阀electromagneticvalve是用不限于液压气动
产品名称:airtac二位三通电磁阀怎样接线
电磁阀(Electromagneticvalve)是用电磁控制的工业设备,是用来控制流体的自动化基础元件,属于执行器,并不限于液压、气动。用在工业控制系统中调整介质的方向、流量、速度和其他的参数。电磁阀可以配合不同的电路来实现预期的控制,而控制的精度和灵活性都能够保证。电磁阀有很多种,不同的电磁阀在控制系统的不同位置发挥作用,最常用的是单向阀、安全阀、方向控制阀、速度调节阀等。
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档