数据手册SFP-GE-BIDI-20KM-T1310/R1490-x-D101.25Gb/s SFP(小型可插拔)Tx1310nm/Rx1490nm双向光收发模块产品简介ModuleTek的SFP-GE-BIDI-20KM-T1310/R1490-x-D10SFP-BIDI光收发模块基于千兆以太网IEEE 802.3标准和光纤通道FC-PI-2Rev7.0,为GE/FC应用提供快速可靠的接口。
该产品通过2线串行总线实现数字诊断功能,符合小型可插拔多源协议(MSA)和SFF-8472的标准。
产品特性高达1.25Gb/s的双向数据传输能力符合IEEE802.3z千兆以太网符合SFP MSA热插拔设计1310nm FP激光发射器单LC接口具有数字诊断功能在9/125um单模光纤上传输距离可达20km单电源供电3.3V符合RoHS标准1类激光产品,符合EN60825-1标准工作温度范围(外壳温度):商业温度等级:0◦C至70◦C工业温度等级:−40◦C至85◦C应用1.25Gb/s千兆以太网1.063Gb/s光纤通道摩泰光电用心做好每一次服务1订购信息型号产品ID 描述拉环颜色SFP-GE-BIDI-20KM-T1310/R1490-C-D10M221501GE/FC ,SFP-BIDI ,单LC 接口,Tx1310nm/Rx1490nm ,传输距离可达20km,商业级蓝色SFP-GE-BIDI-20KM-T1310/R1490-I-D10M221502GE/FC ,SFP-BIDI ,单LC 接口,Tx1310nm/Rx1490nm ,传输距离可达20km ,工业级蓝色注:1.产品ID 为我司产品标准型号的简写订货号如需了解更多信息或订购上述产品,请联系:电子邮件:*******************摩泰光电官网:产品一般规格参数符号最小值典型值最大值单位备注数据速率DR 1.25Gb/s 1DR 1.062Gb/s2误码率BER 10−12工作温度T C 070◦C 3-4085◦C 3储存温度T STO −4085◦C4工作电流I CC 200300mA 5工作电压V CC 3.14 3.33.46V 最大电压V MAX−0.54V5注:1.IEEE 802.32.FC-PI-2Rev7.03.外壳表面温度4.环境温度5.工作电流最大值定义为满流量、模块外壳最高温度下的工作电流;传输距离数据速率光纤类型距离范围(km)备注1.25Gb/s9/125um 单模光纤20光学特性—发射机V CC=3.14V to3.46V,T C参数符号最小值典型值最大值单位备注发射光功率P TX-9-3dBm1光中心波长λC126013101360nm消光比ER9dB光谱宽度(RMS)Δλ5nm光信号上升/下降时间t r/t f250300ps(20%-80%)注:1.1类产品典型光眼图使用1.25Gb/s,PRBS27-1信号测试光学特性—接收机V CC=3.14V to3.46V,T C参数符号最小值典型值最大值单位备注接收机过载P OL0dBm光中心波长λC147014901510nm接收灵敏度R X SEN−23dBm1回波损耗ORL14dBmLOS信号生效LOS A−35dBmLOS信号失效LOS D−24dBmLOS信号迟滞区间LOS H0.5dB注:1.用PRBS27-1测试模式测量,BER<10−12;电气特性—发射机V CC=3.14V to3.46V,T C参数符号最小值典型值最大值单位备注差分输入阻抗R IN100Ω单端输入摆幅V IN PP2501200mV发射机关闭电压V D V CC-1.3V CC V发射机使能电压V EN V EE V EE+0.8V电气特性—接收机V CC=3.14V to3.46V,T C参数符号最小值典型值最大值单位备注单端输出摆幅V OUT PP300400800mV输出信号上升时间/下降时间t r/t f300ps(20%-80%)LOS信号生效V LOS A V CC−0.5V CC HOST VLOS信号失效V LOS D V EE V EE+0.5V 接收端压制功能压制功能的判断方式备注关闭N.AA0H 设备的寄存器说明IIC 地址字节大小寄存器名称寄存器描述取值(HEX)01IdentifierSFP 0311Extended Identifier使用IIC 接口0421Connector使用LC 连接器073-108Transceiver 1000BASE-BX10-U 0000004000000000111Encoding 使用8B/10B 编码方式01121BR,Nominal 1.25Gb/s 的标称速率0D 131Rate Identifier 无速率选择功能00141Length(9μm)-km 在单模光纤传输20km 14151Length (9μm)-100m 在单模光纤传输20km C8161Length (50μm)-10m 在多模光纤的传输距离00171Length (62.5μm)-10m 在多模光纤的传输距离00181Length (Copper)在铜缆的传输距离00191Reserved 未定义0020-3516厂商名称MODULETEKASCII Format361Transceiver 未定义0037-393Vendor OUI 厂商IEEE 公司ID 00000040-5516Vendor PN厂商产品型号由厂商定义56-594Vendor Revision Number厂商产品版本号由厂商定义60-612Wavelength 激光器的波长1310纳米051E 621Reserved 未定义00631CC_BASE 0-62字节的校验和由厂商定义64-652Transceiver Options1.Rx_LOS 信号监控2.Tx_FAULT 信号监控3.Tx_DIS 信号监控001A 661BR,max 高比特率余量00671BR,min 低比特率余量0068-8316Vendor SN 厂商序列号由厂商定义84-918Date code 日期代码由厂商定义921Monitoring TypeDOM 信息内部校准接收光功率测量使用平均光功率68931Enhanced Options 1.发射光与接收光Alarm 与Warning 监控2.Tx_DIS 信号监控与控制3.Rx_LOS 信号监控4.Tx_FAULT 信号监控F0941Compliance 按照12.0版本的SFF-8472定义08951CC_EXT 64-94字节的校验和由厂商定义96-12732Vendor Specific 厂商自定义区域由厂商定义128-255128Vendor Specific厂商自定义区域由厂商定义数字诊断功能SFP-GE-BIDI-20KM-T1310/R1490-x-D10支持SFP MSA中定义的2线串行通信协议,该产品通过地址为0xA2的2线接口访问数字诊断信息。
光模块分类
![光模块分类](https://img.taocdn.com/s3/m/c1576c03866fb84ae45c8d32.png)
光收发一体模块:1.SFP:热插拔光模块,SFP常规产品(双纤双向、单纤双向)、SGMII SFP(百兆千兆速率互转)、多速率传输的SFP光模块(155M~~~2.67G)。
2.XFP:万兆模块,波长有850nm、1310nm、1550nm,距离从220m到80km,LC接口3.SFP+:10.3G的传输速率,850nm和1310nm,距离从330m到20km,LC接口。
4.GBIC:千兆速率,单纤/双纤,850/1310/1490/1550nm,RJ45/SC/LC,100m到120KM。
5.SFF:双纤/单纤,155M/622M/1.25G/2.5G,850/1310/1550nm,550m~~~120Km,LC接口,2X5/2X10小型化封装。
6.1x9:双纤/单纤/单发/单收,SC/FC链接,产品支持定制。
6.GPON:2X10,ONU端,SC插座/尾纤,突发模块式发射/持续模块式接受,突发模式支持DDMI功能,分工业级/商业级两级温度,完全支持SFF MAS协议及ITU-T G.984.2和ITU-TG.984.2—2006的修订版,符合RoHS6。
7.GEPON:SFP封装,SC接口或者其他损失还原连接器,千兆对称,ONU端1310nm的突发模式,1490nm的持续接收模式,OLT端恰好和ONU端相反,支持IEEE 802.3ah 和IEC-60825标准,符合RoHS。
8.EPON:SFF/SFP封装,符合IEEE Std 802.3ah?-2004协议标准,1.25G对称,单纤双向数据传输,1490波长的持续发射模式,1310nm的突然接受模式。
9.SFP EPON:SFP封装,1.25G传输速率,千兆以太网,无源光网OLT端。
10.SFF EPON:OLT端和ONU端,SFF封装,1.25G,10KM距离,1310nm/1490nm。
9.SFP CWDM:SFP封装,155M/622M/1.25G,40Km/80KM,1270nm—1610nm,广泛应用于以太网/光纤通信/同步光纤网/同步数字序列。
一分钟了解80km工业级BiDi光模块
![一分钟了解80km工业级BiDi光模块](https://img.taocdn.com/s3/m/ec116dfd05087632311212dc.png)
一分钟了解80km工业级BiDi光模块随着5G部署的日趋激烈,工业级光模块需求越来越大。
易飞扬(Gigalight)适应市场潮流,在原有产品线基础上,将于近期推出全系列应用于城域网DWDM系统等场景的10G工业级光模块,主要封装形式为XFP和SFP+。
本文将对其中的10G SFP+BiDi光模块做一个简单介绍。
10G SFP+BiDi ZR简介SFP+是一种封装形式,BiDi指单纤双向,即可以在一根光纤上实现双向传输。
ZR代表的是Ze best Range,也就是“最长距离”,支持在单模光纤上传输1550nm波长,传输距离可达到80km,最初是思科推出的私有万兆以太网标准,不在EEE802.3ae标准的物理层协议内,后来参与厂家渐多,变成了MSA的形式。
10G SFP+BiDi ZR光模块的发射机部分采用EML调制的激光器,探测器部分采用APD雪崩二极管方案,内置CDR,较好地提升了模块性能,灵敏度为纤后-22dBm。
对于EML激光器而言,温度是影响发射光波长的重要因素,按业界标准,每1℃引起的波长偏移要小于0.12nm;10G SFP+BiDi80km光模块采取ADI的ADN8833加软件PID算法来控制激光器温度,保证激光器稳定出光。
易飞扬(Gigalight)根据市场需求推出的三款不同的SFP+ZR版本BiDi光模块和传统模块的区别BiDi光模块和传统双纤双向光模块主要区别在于BiDi光模块配备了波分复用(WDM)耦合器,也就是双工器,根据波长的不同将在一根光纤上传输的数据进行汇合和分离。
为了能够高效地工作,BiDi光模块必须配对使用,通过调谐双工器以匹配发射器和接收器的期望波长,实现数据的双向传输。
如下图所示,易飞扬(Gigalight)的10G SFP+BiDi80km 光模块与设备A(上行)和设备B(下行)进行了连接,那么光模块A的双工器必须有一个1550nm的接收波长和一个1490nm的发射波长。
光模块介绍 简介
![光模块介绍 简介](https://img.taocdn.com/s3/m/cd2920abaef8941ea76e0584.png)
按摩对类风湿有效吗文章目录*一、按摩对类风湿有效吗1. 按摩对类风湿有效吗2. 类风湿怎样才能确诊3. 类风湿严重会导致什么后果*二、导致类风湿出现的主要原因*三、类风湿患者什么不能吃呢按摩对类风湿有效吗1、按摩对类风湿有效吗可以先用推、理、揉手法,轻轻按摩,先使患部肌肉松弛,气血畅行;继而使用点、按、捏、拿手法、达到舒筋活络止痛的目的,最后用摇、滚、揉等手法。
每次治疗时间15到30分钟,2到3天一次。
由此可见,按摩对类风湿是有效的。
2、类风湿怎样才能确诊其实现在对于类风湿的检查,一般都是进行对于血象的检查,因为类风湿的发病的过程,一般都是比较慢的,并且如果是比较严重的类风湿的话一般都是会出现比较轻的中度的贫血,如果是活动期的话一般病人还会出现血小板的增高。
并且如果是比较严重的类风湿的话,还有可能还会有一些人还会出现全部血细胞的减少,其实对于类风湿的确诊的方法还可以做血沉和C反应蛋白的检查,类风湿关节活动期,并且血沈加快。
3、类风湿严重会导致什么后果类风湿连累人的关节主要是表现出类风湿性关节炎,发病的具体部位是关节滑膜,并且还会进一步连累到关节软骨,会使得关节的骨质遭到破坏,最后使得关节发生畸形。
类风湿如果不积极治疗,有75%的人会在发病过后三年左右出现关节残废的现象。
导致类风湿出现的主要原因1、环境因素长期居住在寒冷潮湿环境中的人类风湿的发病率远远高于其它人,类风湿主要是由于外部风邪入侵所致,此外,强烈的精神刺激、外伤、营养不良和过度劳累等都会增加类风湿的发病几率。
2、性激素研究表明,类风湿性关节炎存在明显性别差异,男女发病比例越为1:3,且女性患者在妊娠期症状减轻,服用避孕药的女性较少患病,因此认为性激素在类风湿的产生过程中起到了一定作用。
3、内分泌因素类风湿多发生于女性,患者在怀孕期间症状有所减轻,应用肾上腺皮质激素可以抑制该病,因此推断类风湿的发生于内分泌因素存在关系。
4、免疫因素类风湿的产生是由于感染原侵入关节腔,刺激滑膜或者浆细胞,从而产生特异性免疫球蛋白抗体,当抗原抗体复合物形成后抗体就会转化为异体,再次刺激浆细胞就会产生新的抗体,即类风湿因子,从而导致类风湿发生。
光模块型号说明
![光模块型号说明](https://img.taocdn.com/s3/m/548d01ff4693daef5ef73d31.png)
光模块型号中字母含义:
bidi(Bidirectional)单纤双向,因收发采用不同波长,所以双向模块必须成对使用。
T(telegraphy)表示电模块
SX(Short-wave)表示短距,一般指550m的多模光纤
LX(longwave)表示长距,一般指10km的单模光纤
LH(long-haul)表示超长距,后面的数字表明传输距离,单位是km,如:40,70,120等ZX(extended range)与LH相同
MM(multmode)表示多模,后面的数字表明所使用的波长,单位是nm,如:850
SM(single mode)表示单模,后面的数字表明所使用的波长,单位是nm,如:1310,1550等其中的单位说明:
m:米,距离单位,一般用于光纤长度
km:公里,距离单位,一般用于光纤长度
nm:纳米,,距离单位,一般用于光波波长
mw:毫瓦,功率单位
db:分贝,光功率的单位,1mw=0db。
超详细的光模块介绍
![超详细的光模块介绍](https://img.taocdn.com/s3/m/47610266f242336c1eb95e5b.png)
超详细的光模块介绍光模块发展简述光模块分类按封装:1*9 、GBIC、SFF、SFP、XFP、SFP+、X2、XENPARK、300pin 等。
按速率:155M、622M、1.25G、2.5G、4.25G、10G、40G等。
按波长:常规波长、CWDM、DWDM等。
按模式:单模光纤(黄色)、多模光纤(橘红色)。
按使用性:热插拔(GBIC、SFP、XFP、XENPAK)和非热插拔(1*9、SFF)。
封装形式光模块基本原理光收发一体模块(Optical Transceiver)光收发一体模块是光通信的核心器件,完成对光信号的光-电/电-光转换。
由两部分组成:接收部分和发射部分。
接收部分实现光-电变换,发射部分实现电-光变换。
发射部分:输入一定码率的电信号经内部的驱动芯片处理后驱动半导体激光器(LD)或发光二极管(LED)发射出相应速率的调制光信号,其内部带有光功率自动控制电路(APC),使输出的光信号功率保持稳定。
接收部分:一定码率的光信号输入模块后由光探测二极管转换为电信号,经前置放大器后输出相应码率的电信号,输出的信号一般为PECL电平。
同时在输入光功率小于一定值后会输出一个告警信号。
光模块的主要参数1. 传输速率传输速率指每秒传输比特数,单位Mb/s 或Gb/s。
主要速率:百兆、千兆、2.5G、4.25G和万兆。
2.传输距离光模块的传输距离分为短距、中距和长距三种。
一般认为2km 及以下的为短距离,10~20km 的为中距离,30km、40km 及以上的为长距离。
■光模块的传输距离受到限制,主要是因为光信号在光纤中传输时会有一定的损耗和色散。
注意:• 损耗是光在光纤中传输时,由于介质的吸收散射以及泄漏导致的光能量损失,这部分能量随着传输距离的增加以一定的比率耗散。
• 色散的产生主要是因为不同波长的电磁波在同一介质中传播时速度不等,从而造成光信号的不同波长成分由于传输距离的累积而在不同的时间到达接收端,导致脉冲展宽,进而无法分辨信号值。
光模块知识介绍-
![光模块知识介绍-](https://img.taocdn.com/s3/m/0afa0758f12d2af90242e65e.png)
• 按光在光纤中的传输模式可将光纤分为单模光纤和多模光纤两种。 • 多模光纤(MMF,Multi Mode Fiber),纤芯较粗,可传多种模式的光。但其模
间色散较大,且随传输距离的增加模间色散情况会逐渐加重。多模光纤的传 输距离还与其传输速率、芯径、模式带宽有关,具体关系请参见表1‐2。
LC 连接器(Lucent Connector or Local Connector,朗讯连接器),外观图如图1‐
2所示。
注意
为了保护光纤连接器的清洁,请务必保证在未连接光纤时盖上防尘帽。
gigac
9
接口指标
• 输出光功率
输出光功率指光模块发送端光源的输出光功率,单位:dBm。 • 接收灵敏度
接收灵敏度指的是在一定速率、误码率情况下光模块的最小接收光功率,单 位:dBm。一般情况下,速率越高接收灵敏度越差,即最小接收光功率越大, 对于光模块接收端器件的要求也越高。
饱和度),因此请用户使用时关注光纤使用长度,以保证到达光模块的实际 接收光功率小于其光饱和度,否则有可能造成光模块的损坏。
gigac
12
SFP光模块
SFP(Small Form‐factor Pluggables)可以简单的理解为GBIC的升级版本。SFP模块体积比
GBIC模块减少一半,可以在相同面板上配置多出一倍以上的端口数量。由于SFP模块在 功能上与GBIC基本一致,因此,也被有些交换机厂商称为小型化GBIC(Mini‐GBIC)。
成都贝岭科技有限公司 ‐‐‐光模块介绍
gigac
gigac
1
感谢您长期对Gigac的 支持与厚爱
gigac
2
光收发一体模块定义
百科:BIDI SFP光模块和普通SFP光模块的区别
![百科:BIDI SFP光模块和普通SFP光模块的区别](https://img.taocdn.com/s3/m/3de10b5e3a3567ec102de2bd960590c69ec3d8ff.png)
百科:BIDI SFP光模块和普通SFP光模块的区别光模块作为一种应用在光通信网络中的光器件,起到光电信号转换的作用。
但是随着光网络市场的高速进展,光模块的封装和速率都有着几大的增长,而在本文中,易飞扬通信将给大家介绍是SFP光模块。
SFP光模块有BIDI SFP光模块和一般SFP光模块,这两种SFP光模块有各是什么意思?有哪些的区分?各位客官请继续往下看。
BIDI SFP光模块是什么?BIDI光模块是一款用法WDM(波分复用)双向传输技术的光模块,实现了在一根光纤上同时举行光通道内的双向传输。
BIDI光模块仅有一个端口,通过整合的双向耦合器在一根光缆上举行信号的放射与接收。
因此,它必需配对用法。
BIDI光模块如何工作为了能够高效地工作,BIDI光模块必需配对用法,通过调谐双工器以匹配放射器和接收器的期望波长,实现数据的双向传输。
BIDI光模块速率BIDI光模块速率为155Mbps——3.125GbpsBIDI光模块的优势用法BIDI光模块,如:SFP+ BIDI和SFP BIDI光模块,最为显然的优势在于削减了光纤布线基础设施的成本。
BIDI光模块削减了光纤跳线面板上的端口数量,也削减了特地用于光纤管理的托盘占用空间,更削减了所需用法的光缆数量。
一般SFP光模块介绍SFP光模块是SFP封装的热插拔小封装模块,目前最高速率可达10.3G,接口为LC。
并且由激光器(包括放射器TOSA 跟接收器ROSA)和线路板 IC 及外部配件构成,外部配件则有外壳、底座、A、拉环、卡扣、解锁件、橡胶塞组成。
SFP光模块分类①根据速率分:有155M/622M/1.25G/2.125G/4.25G/8G/10G,其中155M 和1.25G市场上用的较多;②根据波长分:有850nm/1310nm/1550nm/1490nm/1530nm/1610nm,波长是850nm为SFP多第1页共2页。
10Gbps 单模 BIDI 1270 1330 光模块产品介绍
![10Gbps 单模 BIDI 1270 1330 光模块产品介绍](https://img.taocdn.com/s3/m/b3081a63a417866fb84a8e3e.png)
FeaturesOperating data rate up to10.3GbpsTwo types:A:1270nm DFB Transmitter/1330nm ReceiverB:1330nm DFB Transmitter/1270nm ReceiverPower budget21dB at leastSingle3.3V Power supply and TTL Logic InterfaceLC Connector InterfaceHot PluggablePower Dissipation<1.5WOperating casetemperature Standard:0°C to+70°CCompliant with SFP+MSA Specification SFF-8431Compliant with IEEE802.3ae10GBASE-ERCompliant with IEEE802.3ae10GBASE-EWApplications10GBASE-ER at10.3125Gbps10GBASE-EW at9.953GbpsOther Optical LinksDescriptionThe10G SFP+BIDI series single mode transceiver is small form factor pluggable module for duplex optical data communications such as10GBASE-LR/LW defined by IEEE802.3ae.It is with the SFP+20-pin connector to allow hot plug capability.The BLSFP-10G23-60-xx module is designed for single mode fiber and operates at a nominal wavelength of1270nm; BLSFP-10G32-60-xx module is designed for single mode fiber and operates at a nominal wavelength of1330nm.The transmitter section uses a multiple quantum well DFB,which is class1laser compliant according to International Safety 10Gbps单模BIDI1270/1330nm60km SFP+光模块--BLSFP-10G23-60-xx 产Standard IEC-60825.The receiver section uses an integrated InGaAs detector preamplifier (IDP)mounted in an optical header and a limiting post-amplifier IC.SpecificationsTable 1-Absolute Maximum RatingsParameter Symbol Min Max Unit Supply Voltage Vcc -0.5 3.6V Storage TemperatureTs-40+85°CTable 2-Recommended Operating ConditionsParameterSymbol Min TypicalMax Unit Operating Case Temperature Tc 0+70°C Power Supply Voltage Vcc 3.153.3 3.45V Surge Current I Surge +30mA Power Supply CurrentIcc430mATable 3-Performance Specifications -ElectricalParameterSymbolMi nTypical MaxUnitNotesTransmitterCML Inputs(Differential)Vin1501200mVppAC coupled inputsInput Impedance Zin 85100115ohms Rin >100kohms@DC(Differential)Tx_DISABLE Input 2Vcc+0.3V Voltage -High Tx_DISABLE Input 00.8V Voltage -Low Tx_FAULT Output 2Vcc+0.3V Io =400μA;Host VccVoltage -High Tx_FAULT Output 00.5VIo =-4.0mAVoltage -Low ReceiverCML Outputs Vout 350700mVpp AC coupled (Differential)outputsOutput Impedance Zout85100115ohms (Differential)Rx_LOS Output 2Vcc+0.3Vlo =400μA;Host VccVoltage -HighRx_LOS Output00.8V lo=-4.0mA Voltage-LowMOD_DEF(2:0)VoH 2.5VWith Serial ID VoL00.5VTable4-Optical and Electrical Characteristics (BLSFP-10G23-60-xx,1270nm DFB&PIN/TIA)Parameter Symbol Min.Typical Max.Unit NotesPower Budget21dBDate Rate9.953/10.3125GbpsTransmitterCentre WavelengthλC126012701280nmSpectral Width(-20dB)∆λ1nmAverage Output Power P out,AVG16dBm1Extinction Ratio ER 3.5dB Side Mode Suppression Ratio SMSR30dB Transmitter and Dispersion Penalty TDP2dBAverage Power of OFF Transmitter-30dBm Relative Intensity Noise RIN-128dB/HzInput Differential Impedance Z IN90100110ΩTX Disable Assert Time t_off10usReceiverCentre WavelengthλC13201340nm Sensitivity P IN-20dBm2 Receiver Overload P MAX-6dBmOutput Differential Impedance P IN90100110ΩLOS De-Assert LOS D-21dBmLOS Assert LOS A-30dBm LOS High2V CC+0.3V00.8Low(BLSFP-10G32-60-xx,1330nm DFB&PIN/TIA)Parameter Symbol Min.Typical Max.Unit Notes Power Budget21dBDate Rate9.953/10.3125GbpsTransmitterCentre WavelengthλC132013301340nmSpectral Width(-20dB)∆λ1nmAverage Output Power P out,AVG16dBm1 Extinction Ratio ER 3.5dB Side Mode Suppression Ratio SMSR30dBTransmitter and Dispersion Penalty TDP2dBAverage Power of OFF Transmitter-30dBm Relative Intensity Noise RIN-128dB/HzInput Differential Impedance Z IN90100110ΩTX Disable Assert Time t_off10usReceiverCentre WavelengthλC12601280nm Sensitivity P IN-20dBm2 Receiver Overload P MAX-6dBmOutput Differential Impedance P IN90100110ΩLOS De-Assert LOS D-21dBmLOS Assert LOS A-30dBmLOS High2V CC+0.3V Low00.8Notes:2.Output is coupled into a9/125μm single-mode fiber.3.Minimum average optical power measured at the BER less than1E-12.The measure pattern is PRBS231-1.SFP+Transceiver Electrical Pad LayoutTable5–Diagnostics SpecificationParameter Range Unit Accuracy Calibration Temperature0to+70°C±3°C Internal/External Voltage 3.0to3.6V±3%Internal/External Bias Current0to100mA±10%Internal/External TX Power0to+5dBm±3dB Internal/External RX Power-23to-3dBm±3dB Internal/ExternalDigital Diagnostic Memory MapThe transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface(SCL,SDA).The diagnostic information with internal calibration or external calibration all are implemented,including received power monitoring,transmitted power monitoring,bias current monitoring,supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following.。
BIDI光模块百科
![BIDI光模块百科](https://img.taocdn.com/s3/m/13f8e506650e52ea551898d5.png)
BIDI 光模块是一种单纤双向光模块,利用WDM 技术,发射和接收两个不同方向的中心波长,实现光信号在一根光纤上的双向传输。
光模块一般都有两个端口:发射端口(TX)和接收端口(RX),而BIDI 光模块只有一个端口,通过光模块中的滤波器进行滤波,同时完成一种波长光信号的发射和另一种波长光信号的接收(BIDI 光模块的波长都是组合形式的),因此BIDI 光模块必须成对使用,它最大的优势就是节省光纤资源。
飞速光纤()为您介绍以下几种类型的BIDI 光模块,供您参考。
一、BIDI SFP 光模块
思科(Cisco)GLC-FE-100BX-D BiDi SFP
百兆单纤双向光模块
二、BIDI SFP+光模块
博科(Brocade)10G-SFPP-BXU BiDi SFP+万兆单纤双向光模块
BIDI 光模块百科
三、BIDI XFP光模块
华三(H3C)XFP-10G-BX60U-I BiDi XFP万兆单纤双向光模块
四、BIDI X2光模块
惠普(HP)X2-10G-BX BiDi X2万兆单纤双向光模块
以上就是几类BIDI光模块的简单介绍,飞速光纤()可供应一系列的光模块,包括上面四类BIDI光模块,以及SFP+光模块、X2光模块、XENPAK光模块、XFP光模块、SFP (mini GBIC)光模块、GBIC光模块、CWDM粗波分复用/DWDM密集波分复用光模块、40G QSFP+
光模块和CFP光模块等,欢迎您来选购。
买光模块&高速线缆,就上飞速光纤!。
思科光模块介绍
![思科光模块介绍](https://img.taocdn.com/s3/m/bc62c63deefdc8d376ee324a.png)
思科光模块介绍思科GBIC封装光模块WS-G5484 GBIC多模光模块(850nm-1.25Gb/s-550M-SC)WS-G5486 GBIC单模光模块(1310nm-1.25Gb/s-10KM-SC)WS-G5483 GBIC电口模块(1.25Gb/s-100M-RJ45)WS-G5487 GBIC单模光模块(1550nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1470 CWDM GBIC单模光模块(1470nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1490 CWDM GBIC单模光模块(1490nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1510 CWDM GBIC单模光模块(1510nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1530 CWDM GBIC单模光模块(1530nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1550 CWDM GBIC单模光模块(1550nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1570 CWDM GBIC单模光模块(1570nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1590 CWDM GBIC单模光模块(1590nm-1.25Gb/s-80KM-SC)CWDM-GBIC-1610 CWDM GBIC单模光模块(1610nm-1.25Gb/s-80KM-SC)思科SFP封装光模块GLC-SX-MM SFP多模光模块(850nm-1.25Gb/s-550M-LC)GLC-LH-SM SFP单模光模块(1310nm-1.25Gb/s-10KM-LC)GLC-ZX-SM SFP单模光模块(1550nm-1.25Gb/s-80KM-LC)GLC-T SFP电口模块(1.25Gb/s-100M-RJ45)CWDM-SFP-1470 CWDM SFP单模光模块(1470nm-1.25Gb/s-80KM-LC)CWDM-SFP-1490 CWDM SFP单模光模块(1490nm-1.25Gb/s-80KM-LC)CWDM-SFP-1510 CWDM SFP单模光模块(1510nm-1.25Gb/s-80KM-LC)CWDM-SFP-1530 CWDM SFP单模光模块(1530nm-1.25Gb/s-80KM-LC)CWDM-SFP-1550 CWDM SFP单模光模块(1550nm-1.25Gb/s-80KM-LC)CWDM-SFP-1570 CWDM SFP单模光模块(1570nm-1.25Gb/s-80KM-LC)CWDM-SFP-1590 CWDM SFP单模光模块(1590nm-1.25Gb/s-80KM-LC)CWDM-SFP-1610 CWDM SFP单模光模块(1610nm-1.25Gb/s-80KM-LC)思科 2.125G SFP封装光模块DS-SFP-2G-FC-SW 1/2G SFP多模光模块(850nm-2.125Gb/s-550M-LC)DS-SFP-2G-FC-LW 1/2G SFP单模光模块(1310nm-2.125Gb/s-10KM-LC)DS-SFP-2G-FC-ZW 1/2G SFP单模光模块(1550nm-2.125Gb/s-80KM-LC)思科 4G SFP封装光模块ONS-SE-4G-MM 4G SFP多模光模块(850nm-4.0Gb/s-550M-LC)100Base SFPGLC-FE-100LX SFP单模光模块(1310nm-125Mb/s-10KM-LC)GLC-FE-100FX SFP多模光模块(1310nm-125Mb/s-2KM-LC)GLC-FE-100EX SFP单模光模块(1310nm-125Mb/s-40KM-LC)GLC-FE-100ZX SFP单模光模块(1550nm-125Mb/s-80KM-LC)思科 BIDI SFP封装光模块GLC-BX-D BIDI SFP单模光模块(TX1490/RX1310nm-1.25Gb/s-10KM-单LC)GLC-BX-U BIDI SFP单模光模块(TX1310/RX1490nm-1.25Gb/s-10KM-单LC)GLC-FE-100BX-D BIDI SFP单模光模块(TX1550/RX1310nm-125Mb/s-10KM-单LC) GLC-FE-100BX-U BIDI SFP单模光模块(TX1310/RX1550nm-125Gb/s-10KM-单LC)思科 SFP WITH DDM封装光模块SFP-GE-S DDM SFP多模光模块(850nm-1.25Gb/s-550M-LC)SFP-GE-L DDM SFP单模光模块(1310nm-1.25Gb/s-10KM-LC)SFP-GE-Z DDM SFP单模光模块(1550nm-1.25Gb/s-80KM-LC)思科 XENPAK封装光模块XENPAK-10GB-SR XENPAK多模光模块(850nm-10.3Gb/s-300M-SC) XENPAK-10GB-LR XENPAK单模光模块(1310nm-10.3Gb/s-10KM-SC) XENPAK-10GB-ER XENPAK单模光模块(1550nm-10.3Gb/s-80KM-SC)思科X2 封装光模块X2-10GB-SR X2多模光模块(850nm-10.3Gb/s-300M-SC)X2-10GB-LR X2单模光模块(1310nm-10.3Gb/s-10KM-SC)X2-10GB-ER X2单模光模块(1550nm-10.3Gb/s-80KM-SC)思科 XFP 封装光模块XFP-10GB-SR XFP多模光模块(850nm-10.3Gb/s-300M-LC)XFP-10GB-LR XFP单模光模块(1310nm-10.3Gb/s-10KM-LC)SFP+SFP+10GB-SR SFP+单模光模块(850nm-10.3Gb/s-300M-SC)SFP+10GB-LR SFP+单模光模块(1310nm-10.3Gb/s-10KM-SC)OC3/OC12/OC48 SFPSFP-OC3-MM OC3 SFP多模光模块(1310nm-155Mb/s-2KM-LC)SFP-OC3-SR OC3 SFP多模光模块(1310nm-155Mb/s-2KM-LC)SFP-OC3-IR1 OC3 SFP单模光模块(1310nm-155Mb/s-15KM-LC)SFP-OC3-LR1 OC3 SFP单模光模块(1310nm-155Mb/s-40KM-LC)SFP-OC3-LR2 OC3 SFP单模光模块(1550nm-155Mb/s-80KM-LC)SFP-OC12-MM OC12 SFP多模光模块(1310nm-622Mb/s-2KM-LC)SFP-OC12-SR OC12 SFP多模光模块(1310nm-622Mb/s-2KM-LC)SFP-OC12-IR1 OC12 SFP单模光模块(1310nm-622Mb/s-15KM-LC)SFP-OC12-LR1 OC12 SFP单模光模块(1310nm-622Mb/s-40KM-LC)SFP-OC12-LR2 OC12 SFP单模光模块(1550nm-622Mb/s-80KM-LC)SFP-OC48-SR OC48 SFP多模光模块(1310nm-2.67Gb/s-2KM-LC)SFP-OC48-IR1 OC48 SFP单模光模块(1310nm-2.67Gb/s-15KM-LC)SFP-OC48-LR2 OC48 SFP单模光模块(1310nm-2.67Gb/s-40KM-LC)SFP-OC48-LR1 OC48 SFP单模光模块(1310nm-2.67Gb/s-80KM-LC)光收发一体模块(SFP GBIC XFP)由光电子器件、功能电路和光接口等组成,光电子器件包括发射和接收两部分。
10G 光模块
![10G 光模块](https://img.taocdn.com/s3/m/e06f7ff3dc3383c4bb4cf7ec4afe04a1b071b03a.png)
10G 光模块10G 光模块类型封装形式:SFP+, XFP, X2 ,XENPAK模块传输速率:10Gbps的光纤模块介质:光纤,实现高宽带和远距离的数据传输。
与网络设备(如交换机,路由器,服务器等)进行链接。
支持:单模,多模传输1.确认设备的兼容性2.距离3.波长规格4.温度范围:商温0~70,工温-40~85,扩展级-20~85产品类型:DWDM SFP+, BIDI SFP+按照不同的封装形式:SFP+光模块波长:850nm, 1310nm, 1550nm10G SR SFP+(短距):使用850nm波长适用于多模光纤,传输距离可达300m。
10G多模光模块(10 Gigabit Multimode Fiber, 10G MMF)是一种用于光纤通信系统的网络设备,它能够在多模光纤上实现最高10Gbps的数据传输速率。
这种光模块主要应用于数据中心、企业网络和高带宽需求的网络环境。
10G LR SFP+(长距):使用1310nm波长,可通过单模光纤传输,传输距离可达10km。
适用于长距离的校园网或城域网连接。
10G ER SFP+(超长距):使用单模光纤,在1550nm波长处可实现长达40km的传输距离。
10G ZR SFP+(极长距):用于超长距离传输,该类型使用1550nm波长在单模光纤上进行传输,可达到80km的传输距离。
同样,XFP : 10G SR XFP ,10G LR XFP ,10G ER XFP ,10G ZR XFPX2和XENPAK光模块10G SR/LR/ER/ZR X2:早期用于10G连接的光模块,在SFP+和XFP光模块普及之前使用较多。
它们体积较大,但仍可在支持其封装旧设备中使用。
10G SR/LR/ER/ZR XENPAK:早期第一代10G模块,其封装与特定大小的设备兼容。
BIDI光模块10G BIDI:BIDI(双向)光模块可使用单根光纤完成信号的发射与接收,有效地减少连接所需的光纤数量。
基于低成本建网的BIDI光模块在MAR组网中的应用与实践
![基于低成本建网的BIDI光模块在MAR组网中的应用与实践](https://img.taocdn.com/s3/m/be17f66b5627a5e9856a561252d380eb629423e1.png)
65技术交流2023.12·广东通信技术DOI:10.3969/j.issn.1006-6403.2023.12.014基于低成本建网的BIDI 光模块在MAR 组网中的应用与实践[何世东 姚利民]通过分析在打造面向综合承载的智能城域网过程中碰到的环路纤芯资源紧张,且重新敷设光缆周期长、造价高等痛点问题,基于低成本建网策略,创新性的提出了在纤芯资源紧张的段落采用BIDI 光模块快速开通解决方案。
何世东中电科普天科技股份有限公司,高级工程师,主要研究方向为移动通信咨询规划设计。
姚利民中国联合网络通信有限公司江西省分公司,高级工程师,主要研究方向为通信网络建设管理。
关键词:智能城域网 IP_RAN MAR BIDI 光模块 低成本摘要1 案例背景5G 网络建设的开展给本地承载网在大带宽、网络切片、网络SDN 能力、时间同步等方面提出了更多新的需求,现有IP_RAN 网络不具备大带宽、网络切片等能力,难以满足5G 基站业务的承载,为解决上述挑战,运营商提出了构建一张“网络结构简化、网络协议简化、网络设备简化、网络控制和网络管理智能化”的新型智能城域网络。
智能城域网的核心设备(MCR )与汇聚设备(MER )数量较少,且全部安装在核心汇聚机房;但接入设备(MAR )用来满足5G 站点的接入,随无线站点进行部署,具有数量多、分散广的特点,MAR 接入环组网对接入光缆需求很大,考虑原有IP_RAN 网络上承载了大量3G/4G 、宽带等业务,短期内无法退网,使得原来IPRAN组网纤芯无法腾退给MAR 组网使用,且随着光缆建设难度越来越大,采用一种创新性的建网方式,达到建设周期短、操作简单、成本低且后期维护便利成为了迫在眉睫的问题。
2 案例描述2.1 智能城域网建设方式根据网络建设要求,MAR 设备应以综合业务接入点及BBU 集中点为覆盖目标,依托现有光缆资源,采用环形双挂的方式到所属汇聚区的成对汇聚MER 设备上。
光模块参数
![光模块参数](https://img.taocdn.com/s3/m/dcbd0a57804d2b160b4ec09b.png)
1X9 1X9 1X9 1X9 1X9 1X9 CWDM CWDM CWDM
155M 1.25G 1.25G 1.25G 2.5G 2.5G 1.25G 1.25G 2.5G
-13 ~ -5 -13 ~ -5 -10 ~ -2 -10 ~ -2 -2 ~ 3 -2 ~ 3 0~5 0~5 -5 ~ 1 -5 ~ 1 0~5 0~5
PIN PIN PIN PIN PIN PIN APD APD PIN PIN APD APD
<-20 <-21 <-22 <-22 <-26 <-26 <-30 <-30 <-18 <-18 <-27 <-27
SFP光模块参数
产品序列号 封装形式 工作速率 工作波长 传输距离 接口类型 激光器 光功率 探测器 灵敏度 数字诊断 工作温度
FPSP311ML-40 FPSP551ML-80 FPMP851GL-05 FPMP311GL-2 FPSP311GL-20 FPSP551GL-80 FPSP551GL-120 FPSP551GL-150 FPSP312GL-20 FPSP552GL-80
Tx1310 /Rx1550 Tx1550 /Rx1310 Tx1310 /Rx1550 Tx1550 /Rx1310 Tx1490/ Rx1550 Tx1550/ Rx1490 Tx1490/ Rx1550 Tx1550/ Rx1490 Tx1310 /Rx1550 Tx1550 /Rx1310 Tx1490/ Rx1550 Tx1550/ Rx1490
8
武汉飞鹏光科技有限公司
1*9光模块参数
产品序列号 封装形式 工作速率 工作波长 传输距离 1X9 接口类型 激光器 光功率 探测器 灵敏度 工作温度
SFP光模块详解,看看有哪些是你不知道的!
![SFP光模块详解,看看有哪些是你不知道的!](https://img.taocdn.com/s3/m/a6cca66b01f69e31433294e0.png)
SFP 光模块的封装形式是热插拔小封装,目前最高速率可达10G,LC 接口为多。
SFP 的缩写为Small Form-factor Pluggable,可以简单理解为GBIC 的升级版本。
SFP 光模块体积比GBIC 光模块减少一半,可以在相同的面板上配置多出一倍以上的端口数量。
一、SFP 光模块的外观与结构:SFP 光模块由激光器、线路板IC 和外部配件构成,外部配件包含有外壳、解锁件、卡扣、底座、拉环、橡胶塞,PCBA,拉环的颜色可以帮助大家辨别模块的参数类型。
二、SFP 光模块分类:SFP 光模块详解,看看有哪些是你不知道的!速率:155M、1.25G、2.5G、4.25G波长:短距、中距、长距传输模式:电口、单模(SM)、多模(MM)三、SFP光模块的类型:BIDI-SFP:单纤双向SFP,利用WDM技术,发送和接收两个方向的不同的中心波长,从而实现一根光纤双向传输光信号。
BIDI光模块只有1个端口,通过光模块中的滤波器进行滤波,同时完成1310光信号的发射和1550nm光信号的接收,或者相反。
因此,BIDI光模块必须成对使用。
Copper SFP:电口SFP光模块,采用SFP的封装形式,电口模块,可支持最大传输距离100m(RJ45,5类双绞线为传输介质)。
CWDM SFP:采用了CWDM技术,可以通过外接波分复用器,将不同波长的光信号复合在一起,通过一根光纤进行传输,从而节约光纤资源。
同时,接收端需要使用波分复用器对复光信号进行分解。
CWDM SFP光模块分为18个波段,从1270nm~1610nm,每两个波段之间间隔20nm,一般会用颜色来区分不同波段的光模块。
DWDM SFP:属于密集波分复用技术,可以将不同波长的光耦合到单芯光纤中去,一起传输,DWDM SFP的通道间隔根据需要有0.4nm,0.8nm,1.6nm等不同的间隔,间隔较小、需要额外的波长控制器件。
DWDM SFP的一个关键优点是它的协议和传输速度是不相关的。
单纤双向的光模块
![单纤双向的光模块](https://img.taocdn.com/s3/m/9f9e8b48f02d2af90242a8956bec0975f465a4f6.png)
单纤双向的光模块
单纤双向光模块,也称为BiDi(Bidirectional)光模块,是一种特殊的光模块类型,其主要特点是在一根光纤中可以同时传输两个方向的光信号。
这种光模块主要用于光通信领域,包括电信和双向数据通信。
其工作原理是通过光模块中的滤波器进行滤波,同时完成TX光信号的发射和RX光信号的接收或者相反。
这样,就可以在一根光纤中实现双向通信,提高了光纤资源的利用率。
单纤双向光模块有多种速率可选,如155M、1.25G、10G、16G、25G、40G、100G等。
而且,它使用的波长并不会产生较大的色散代价,传输指标方面与双纤双向光模块并无其它区别。
然而,由于其在成本上具有明显的优势,且不需要增加维护管理,因此光纤直连一般采用单纤双向方案。
此外,单纤双向光模块的结构紧凑,使得它在空间受限的环境中具有更大的应用优势。
同时,随着技术的发展,现在的单纤双向光模块已经可以实现更远的传输距离和更高的传输速率。
总的来说,单纤双向光模块是一种高效、经济、实用的光模块解决方案,广泛应用于各种需要光纤通信的场合。