钢丝绳常用拉力和重量
钢丝绳破断拉力参数
1 钢丝绳重量及最小破断拉力计算1.1 重量重量钢丝绳参考重量按下式计算:2KDM=式中:M–钢丝绳单位长度的参考重量,kg/100m;D–钢丝绳的公称直径,mm;K–充分涂油的某一结构钢丝绳单位长度的重量系数,K值在表1给出。
kg/100·mm2。
1.2 破断拉力钢丝绳实测破断拉力应不低于表2~4的规定。
钢丝绳最小破断拉力用kN 表示,并按下式计算:1000RDKF 2⋅⋅='式中:0F–钢丝绳最小破断拉力,kN;D–钢丝绳的公称直径,mm;R–钢丝绳公称抗拉强度,Mpa;'K–某一指定结构钢丝绳的最小拉力,系数('K值见表1)。
1.3 力学性能1.3.1 第一组6×7类直径8~36mm直径14~36mmWORD完美格式技术资料专业整理表2 第一组6×7类力学性能WORD完美格式1.3.2 第二组6×19类直径12~36mm直径12~40mmWORD完美格式技术资料专业整理表3 第一组6×19类力学性能1.3.3 第三组6×37类直径12~44mm直径20~40mm直径22~46mm直径12~44mm 直径20~40mm 直径22~46mm直径14~44mm 直径18~60mm 直径20~60mm直径32~56mm 直径36~60mm 直径36~64mm表4 第一组6×37类力学性能钢丝绳结构:6×25Fi+FC 6×25Fi+IWR 6×26WS+FC 6×26WS+IWR 6×29Fi+FC 6×29Fi+IWR 6×31WS+FC 6×31WS+IWR 6×36WS+FC 6×36WS+IWR 6×37S+FC 6×37S+IWR技术资料专业整理起重钢丝绳的安全系数是多少1.用于固定起重设备为3.52.用于人力起重为4.53.用于机动起重为5-6 M1-3 4 M44.5 M55.5 M6 6 M7 7 M8 9双绳抓斗(双电机分别驱动)6.0双绳抓斗(单电机集中驱动)5.04.用于绑扎起重物为105.用于供人升降用为14技术资料专业整理。
钢丝绳破断拉力一览表
钢丝绳破断拉力表
我公司常用起重钢丝绳型号为6×37+1,公称抗拉强度为170kg/mm2,以下为几种常用直径的钢丝绳的破断拉力
钢丝绳破断拉力现场简单估算公式:
S = D2×52
式中S为破断拉力,单位为kg
D为钢丝绳直径,单位为mm
钢丝绳使用安全系数表
钢丝绳拉力计算举例:
1.一根钢丝绳,吊装10t重设备,两股受力,是否满足要求
钢丝绳破断拉力为29600kg,安全系数取10,则单股可受力2960kg,两股共5920kg,不能满足要求;
反过来计算,现在使用钢丝绳四股吊装10t重设备,则单股受力约为2500kg,可计算安全系数为,满足要求。
钢丝绳破断拉力一览表
钢丝绳破断拉力表
我公司常用起重钢丝绳型号为6×37+1,公称抗拉强度为170kg/mm2,以下为几种常用直径的钢丝绳的破断拉力
钢丝绳破断拉力现场简单估算公式:
S = D2×52
式中S为破断拉力,单位为kg
D为钢丝绳直径,单位为mm
钢丝绳使用平安系数表
钢丝绳拉力计算举例:
1.一根21.5mm钢丝绳,吊装10t重设备,两股受力,是否满足要求?
21.5mm钢丝绳破断拉力为29600kg,平安系数取10,那么单股可受力2960kg,两股共5920kg,不能满足要求;
反过来计算,现在使用21.5mm钢丝绳四股吊装10t重设备,那么单股受力约为2500kg,可计算平安系数为11.84,满足要求。
【本文档内容可以自由复制内容或自由编辑修改内容期待你的好评和关注,我们将会做得更好】。
钢丝绳技术参数
机械绳参数(续)钢丝绳技术参数表:34×7+FC、34×7+IWS、36×7+FC、36×7+IWS钢丝绳技术参数表:35W×7、24W×7钢丝绳技术参数表:6V×18+FC、6V×18+IWR、6V×19+FC、6V×19+IWR钢丝绳技术参数表:6V×21+7FC、6V×24+7FC钢丝绳技术参数表:6V×30+FC、6V×30+IWR钢丝绳技术参数表:6V×34+FC、6V×34+IWR、6V×37+FC、6V×37+IWR、6V×43+FC、6V×43+IWR钢丝绳技术参数表:6V×37S+FC、6V×37S+IWR钢丝绳技术参数表:4V×39S+5FC、4V×48S+5FC钢丝绳技术参数表:6T×7结构钢丝绳最小破断拉力钢丝绳技术参数表:6T×7结构钢丝最小破断拉力总和钢丝绳技术参数表:6T×19S、6T×19W及6T×25Fi结构钢丝绳最小破断拉力钢丝绳技术参数表:6T×19S、6T×19W及6T×25Fi结构钢丝破断拉力总和钢丝绳公称直径钢丝绳近似重量/(kg/100m)钢丝绳公称抗拉强度/MPa1470 1570 1670 1770 1870 D/mm 允许偏差/% 钢丝绳最小破断拉力/KN16+7至0105 167 179 190 201 21318 133 212 226 240 255 26920 164 261 279 297 314 33222 198 361 337 359 380 40224 236 376 402 427 453 47826 277 441 471 501 531 56128 321 512 547 581 616 65130 369 588 628 668 707 74732 420 669 714 759 805 85034 474 755 806 857 909 96036 531 846 904 961 1020 108018×7+IWS18×19S+IWS 18×19W+IWS34×7+FC36×7+FC公称直径近似重量公称抗拉强度1570 1670 1770 1870mmKg/100m 钢丝绳最小破断力纤维芯 FC钢芯IWR纤维芯 FC钢芯IWR纤维芯 FC钢芯IWR纤维芯 FC钢芯IWR纤维芯 FC钢芯IWR6 13.8 14.5 18.0 18.5 19.1 19.7 20.3 20.9 21.4 22.07 18.8 19.7 24.5 25.3 26.0 26.8 27.6 28.5 29.1 30.08 24.5 25.7 32.0 32.9 34.0 35.0 36.1 37.2 38.1 39.29 31.0 32.6 40.5 41.7 3.0 44.3 45.7 47.0 48.2 49.610 38.3 40.2 50.0 51.5 53.1 54.7 56.4 58.1 59.5 61.311 46.3 48.6 60.5 62.3 64.3 66.2 68.2 70.3 72.0 74.212 55.1 57.9 72.0 74.2 76.5 78.8 81.2 83.6 85.7 88.313 64.7 67.9 84.5 87.1 89.8 92.5 95.3 98.1 100 10314 75.0 78.8 98.0 101 104 107 111 114 116 12016 98.0 103 128 132 136 140 144 149 152 15718 124 130 162 167 172 177 183 188 192 198。
钢丝绳常用系数
钢丝绳常用数据一、钢丝绳最大许用拉力计算(1)拉力计算公式:〖S〗≤P/K公式中〖S〗——钢丝绳允许用拉力(KN)P———钢丝绳破断拉力(KN)K———钢丝绳的安全系数(2)钢丝绳安全系数:(3)钢丝绳破断拉力1、6×19钢丝绳破断拉力2、6×37钢丝绳破断拉力3、6×61钢丝绳破断拉力二、钢丝绳报废标准(1)、钢丝绳直径减少,当直径磨损不超过30%,可允许降低拉力使用,如果超过30%,要进行报废处理。
(2)、钢丝绳经过长期使用后,由于受自然条件和化学腐蚀,当整个钢丝绳外表面受腐蚀的麻面,从外观检查明显时,则该钢丝绳已不能使用。
另一方面,整根钢丝绳纤维芯被挤出,使钢丝绳结构受到破坏时,也不能继续使用。
(3)、钢丝断丝后的报废标准,见下表。
破断拉力计算 Breaking force calculation: Fo = K' D2 Ro/1000Fo —钢丝绳最小破断拉力,单位为kN;Minimum breaking load of wire rope (kN)D —钢丝绳公称直径,单位为mm;Nominal diameter of wire rope (mm)Ro —钢丝绳公称抗拉强度,单位为MPa;Nominal tensile strength of wire rope (MPa).K' —某一指定结构钢丝绳的最小破断拉力系数(见表一表二)Minimum breaking load coefficient of wire rope (see list 1 and list 2).重量计算 Weight calculation: M = K·D2M —钢丝绳单位长度的参考重量,单位为:kg/100m;Reference weight of unit length of wire rope (kg/100m)D —钢丝绳的公称直径,单位为mm; Nominal diameter of wire rope (mm)K —充分涂油的某一结构钢丝绳单位长度的重量系数,单位为kg/100m·mm2。
钢丝绳破断拉力全全参数
1 钢丝绳重量及最小破断拉力计算1.1 重量重量钢丝绳参考重量按下式计算:2KDM=式中:M–钢丝绳单位长度的参考重量,kg/100m;D–钢丝绳的公称直径,mm;K–充分涂油的某一结构钢丝绳单位长度的重量系数,K值在表1给出。
kg/100·mm2。
1.2 破断拉力钢丝绳实测破断拉力应不低于表2~4的规定。
钢丝绳最小破断拉力用kN 表示,并按下式计算:1000RDKF 2⋅⋅='式中:0F–钢丝绳最小破断拉力,kN;D–钢丝绳的公称直径,mm;R–钢丝绳公称抗拉强度,Mpa;'K–某一指定结构钢丝绳的最小拉力,系数('K值见表1)。
1.3 力学性能1.3.1 第一组6×7类直径8~36mm直径14~36mm实用文档标准表2 第一组6×7类力学性能实用文档1.3.2 第二组6×19类直径12~36mm直径12~40mm实用文档标准表3 第一组6×19类力学性能1.3.3 第三组6×37类直径12~44mm直径20~40mm直径22~46mm直径12~44mm直径20~40mm直径22~46mm直径14~44mm直径18~60mm直径20~60mm直径32~56mm直径36~60mm直径36~64mm表4 第一组6×37类力学性能钢丝绳结构:6×25Fi+FC 6×25Fi+IWR 6×26WS+FC 6×26WS+IWR 6×29Fi+FC 6×29Fi+IWR 6×31WS+FC 6×31WS+IWR 6×36WS+FC 6×36WS+IWR 6×37S+FC 6×37S+IWR标准起重钢丝绳的安全系数是多少1.用于固定起重设备为3.52.用于人力起重为4.53.用于机动起重为5-6 M1-3 4 M44.5 M55.5 M6 6 M7 7 M8 9双绳抓斗(双电机分别驱动)6.0双绳抓斗(单电机集中驱动)5.04.用于绑扎起重物为105.用于供人升降用为14标准。
纲丝绳许用拉力标准
0.6t 1t 1.4t 2t 2.5t 3.2t 3.9t 4.8t 5.7t 6.7t 7.8t 9t 10.2t 11.5t 12.9t 16t 19.3t 23t 26.9t 31.3t 35.6t
(一)说明:1、表中许应拉力系指单根钢丝绳在垂直状态下的拉力;2、钢丝绳的许应拉力随夹角增大 而减小,一般应小于60℃,而严禁大于120℃;3、各类绳头(插编、铝合金冲压头等)处严禁做挂点;4 、达到断股等报废标准的钢丝绳严禁使用;5、使用钢丝绳应严格执行“宁大勿小”的原则。 (二)钢丝绳承吊重量经验公式:单根钢丝绳垂直承吊重量P( T )可按绳的最小直径D(mm)的平方 乘以0.8后小数点左移两位取值。即:P(垂直承吊重量T)=D(mm)2×0.8×0.01 P值略小于参数表中的数值 P(许应拉力)=钢丝绳破断拉力(选抗拉强度1700 材质)× 折减系数(选0.85或0.82)÷ 安全系数(选6) 1Kg=9.8N(约10N) 1T=98000N=9.8kN(约10kN)
0.3t 0.5t 0.7t 1t 1.3t 1.7t 2t 2.5t 3t 3.6t 4.1t 4.7t 5.4t 6t 6.9t 8.5t 10.3t 12.2t 14.3t 16.6t 19.1t
8.7 11 13 15 17.5 19.5 21.5 24 26 28 30 32.5 34.5 36.5 39 43 47.5 52 56 60.5 65
钢丝绳许应拉力标准
6× 19+1规格钢丝绳
直径mm 断面积mm2 每米重量 许应拉力
6× 37+1规格钢丝绳
直径mm 断面积mm2 每米重量 许应拉力
6.2 7.7 9.3 11 12.5 14 15.5 17 18.5 20 21.5 23 24.5 26 28 31 34 37 40 43 46
钢丝绳技术参数
K 一一钢丝绳的安全系数,按表 5 取用。 表5
用 途 安全系数 3.5 4.5 5~6
钢丝绳的安全系数
用 途 安全系数 6~7 8~10 14
作缆风 用于手动起重设备 用于机动起重设备
作吊索,无弯曲 表6 钢丝绳报废标准(一个节距内的断丝数)
(续)
直 钢丝绳 径 钢丝总截 钢 丝 面 积 参考重量 1400 钢丝绳公称抗拉强度(N/ mm2) 1550 1700 1850 2000
钢丝绳破断拉力总和 (mm) 14.0 16.5 19.5 22.0 25.0 27.5 30.5 33.0 36.0 38.5 41.5 44.0 47.0 50.0 55.5 61.0 66.5 72.0 77.5 83.0 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 (mm2) (㎏/100m) 71.83 103.43 140.78 183.88 232.72 287.31 347.65 413.73 485.55 563.13 640.45 735.51 830.33 930.88 1149.24 1390.58 1654.91 1942.22 2252.51 2585.79 67.52 97.22 132.3 172.3 218.3 270.1 326.8 388.9 456.4 529.3 607.7 691.4 780.5 875.0 1080.3 1307.1 1555.6 1825.7 2117.4 2430.6 100.50 144.50 197.00 257.00 325.50 402.00 486.50 579.00 679.50 788.00 905.00 1025.00 1160.00 1300.00 1605.00 1945.00 2315.00 2715.00 3150.00 3620.00 kN 111.00 160.00 218.00 285.00 360.50 445.00 538.50 641.00 752.50 872.50 1000.00 1140.00 1285.00 1440.00 1780.00 2155.00 2565.00 3010.00 3490.00 4005.00 (不小于) 122.00 175.50 239.00 312.50 395.50 488.00 591.00 703.00 825.00 957.00 1095.00 1250.00 1410.00 1580.00 1950.00 2360.00 2810.00 3300.00 3825.00 4395.00 132.00 191.00 260.00 340.00 430.50 531.50 643.00 765.00 898.00 1040.00 1195.00 1360.00 1535.00 1720.00 2125.00 2570.00 3060.00 3590.00 4165.00 4780.00 143.50 206.50 281.50 367.50 465.00 574.50 695.00 827.00 971.00 1125.00 1290.00 1470.00 1660.00 1860.00 2295.00
常用钢丝绳型号(图)、直径、拉力表
钢丝绳6*37(执行尺度:GB/T 20118-2006)NominalDiameter 钢丝绳公称直径Approx.Weight钢丝绳近似重量Strength of Rope 钢丝绳公称抗拉强度(MPa)1570167017701870Minimum Breaking Load of Rope 钢丝绳最小破断拉力D AllowedTolerance允许偏差NF天然纤维芯钢丝绳SF合成纤维芯钢丝绳IWR/IWS钢芯钢丝绳FC纤维芯钢丝绳IWR/IWS钢芯钢丝绳FC纤维芯钢丝绳IWR/IWS钢芯钢丝绳FC纤维芯钢丝绳IWR/IWS钢芯钢丝绳FC纤维芯钢丝绳IWR/IWS钢芯钢丝绳mm kg/100m KN 5678910111213141618 20 22 24 26 28 30 32 34 36 38 ±6%8.6512.5017.0022.1028.0034.6041.9049.8058.5067.8088.60112.00138.00167.00199.00234.00271.00311.00354.00400.00448.00500.008.4312.1016.5021.6027.3033.7040.8048.5057.0066.1086.30109.00135.00163.00194.00228.00264.00303.00345.00390.00437.00487.009.5313.7018.7024.4030.9038.1046.1054.9064.4074.7097.50123.00152.00184.00279.00258.00299.00343.00390.00440.00494.00550.0011.6016.7022.7029.6037.5046.3056.0066.7078.3090.80119.00150.00185.00224.00267.00313.00363.00417.00474.00535.00600.00669.0012.5018.0024.5032.1040.6050.1060.6072.1084.6098.20128.00162.00200.00242.00288.00339.00393.00451.00513.00579.00649.00723.0012.3017.7024.1031.5039.9049.3059.6070.9083.3096.60126.00160.00197.00238.00284.00333.00386.00443.00504.00570.00638.00711.0013.3019.2026.1034.1043.2053.3064.5076.7090.00104.00136.00173.00213.00258.00307.00360.00478.00479.00546.00616.00690.00769.0013.1018.8025.6033.4042.3052.2063.2075.2088.20102.00134.00169.00209.00253.00301.00353.00409.00470.00535.00604.00677.00754.0014.1020.3027.7036.1045.7056.5068.3081.3095.40111.00145.00183.00226.00273.00325.00382.00443.00508.00578.00653.00732.00815.0013.8079.9027.0035.3044.7055.2066.7079.4093.20108.00141.00179.00221.00267.00378.00373.00432.00496.00565.00638.00715.00797.0014.9021.5029.2038.2048.3059.7072.2085.90101.00117.00153.00193.00239.00289.00344.00403.00468.00537.00611.00690.00773.00861.0040 42 4446 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80554.00610.00670.00732.00797.00865.00936.001010.001090.001160.001250.001330.001420.001510.001600.001700.001790.001890.002000.002110.002210.00539.00594.00652.00773.00775.00843.00911.00983.001060.001130.001210.001300.001380.001470.001560.001650.001750.001850.001950.002050.002160.00610.00672.00738.00806.00878.00953.001030.001170.001190.001280.001370.001460.001560.001360.001760.001870.001980.002090.002200.002320.002440.00741.00817.00897.00980.001070.001160.001250.001350.001450.001560.001670.001780.001900.002020.002140.002270.002400.002540.002680.002820.002960.00801.00883.00970.001060.001150.001250.001350.001460.001570.001680.001800.001930.002050.002180.002320.002450.002600.002740.002890.003050.003210.00788.00869.00954.001040.001140.001230.001330.001440.001540.007660.001770.007890.002020.002750.002280.002410.002550.002700.002850.003000.003150.00852.00940.001030.001130.001230.001330.001440.001550.001670.001790.001920.002050.002180.002320.002460.002610.002760.002920.003080.003240.003410.00835.00921.001010.001100.001200.001310.001410.001520.001640.001760.001880.002010.002140.002270.002410.002560.002710.002860.003020.003180.003340.00903.00996.001090.001190.001300.001410.001530.001650.001770.001900.002030.002170.002310.002460.002610.002770.002930.003090.003260.003440.003610.00883.00973.001070.001170.001270.001380.001490.001610.001730.001860.001990.002120.002260.002400.002550.002700.002860.003020.003190.003360.003530.00954.001050.001150.001260.001370.001490.001610.001740.001870.002010.002150.002290.002440.002600.002760.002920.003090.003270.003450.003630.003820.00Main Applications:Various equipment for derricking,lfting and drawing钢丝绳6*37的主要用途:各种起重、提升和牵引设备钢丝绳6*37的最小钢丝绳破断拉力总和=钢丝绳最小破断拉力×1.226(纤维芯)或×1.321(钢芯)钢丝绳6*19(执行尺度:GB/T 20118-2006)Nominal Diameter 钢丝绳公称直径Approx.Weight钢丝绳近似重量Nominal Tensile Strength of Rope 钢丝绳公称抗拉强度(MPa)1570167017701870Minimum Breaking Load of Rope 钢丝绳最小破断拉力DAllowedToleranceNF天然纤SF合成纤IWR/IWSFC纤维芯IWR/IWSFC纤维芯IWR/IWSFC纤维芯IWR/IWSFC纤维芯IWR/IWS76 78 802000.002110.002210.001950.002050.002160.001660.01760.001870.001980.02090.02200.02320.02440.01850.01970.002100.02230.02360.02500.02640.02780.002930.03080.01880.02000.02130.02270.002410.02550.02700.002850.03010.03170.03340.01970.002100.02230.02370.002510.02660.02810.02960.03120.03280.02270.002420.02560.02720.002870.003040.03200.03370.003550.02090.02230.02370.002510.02660.02820.02980.03140.03310.03480.02120.02260.02410.02560.02720.002880.03050.03220.03390.03580.03760.002070.002210.02350.02500.02650.02810.02980.03140.03320.03490.03670.02240.02390.02540.02700.002870.003040.03220.03400.03590.03780.003970.00Main Applications:Various equipment for derricking,lfting and drawing钢丝绳6*19的主要用途:各种起重、提升和牵引设备钢丝绳6*19的最小钢丝绳破断拉力总和=钢丝绳最小破断拉力×1.249(纤维芯)或×1.336(钢芯)钢丝绳6*19S、6*19W(执行尺度:GB/T 20118-2006)NominalDiameter 钢丝绳公称直径Approx.Weight钢丝绳近似重量Nominal Tensile Strength of Rope 钢丝绳公称抗拉强度(MPa)1570167017701870Minimum Breaking Load of Rope 钢丝绳最小破断拉力78 802240.002360.002190.002300.002470.002590.003150.003320.003400.003580.003350.003530.003620.003800.003550.003740.003830.004030.003750.003950.004050.004260.00Main Applications:Various equipment for hoisting, derricking,lifting, towing, port load and unload, blast furnace hoisting and oil well drilling.The rope with wire core can be used under the shock load, heated and squeezed conditions.钢丝绳6*19S、6*19W的主要用途:各种起重、提升和牵引设备、港口装卸、高炉卷扬、石油钻井、金属芯绳适用于冲击负荷,受热和受挤压条件下。
钢丝绳破断拉力一览表格
.钢丝绳破断拉力表
我企业常用起重钢丝绳型号为6× 37+1,公称抗拉强度为170kg/mm2,以下为几种常用直径的钢丝绳的破断拉力
直径( mm )钢丝总断面积重量钢丝绳破断钢丝绳钢丝(mm2)(kg / m)拉力( kg)
4730 117400
1310650
1514500
18950
23950
129600 2435800
2642650
2850050
66650 432118500
653266500
钢丝绳破断拉力现场简单估量公式:
S = D2×52
.
式中 S 为破断拉力,单位为kg
D 为钢丝绳直径,单位为mm
钢丝绳使用安全系数表
使用状况安全系数
用做缆风绳时
用做吊索无曲折时6到 7
用于灵活起重设施时5到 6
用于捆绑时8到 10
用于载人起落机时14
钢丝绳拉力计算举例:
1.一根 21.5mm 钢丝绳,吊装10t 重设施,两股受力,能否
知足要求?
21.5mm 钢丝绳破断拉力为29600kg,安全系数取10,则单股可受力2960kg,两股共5920kg,不可以知足要求;
反过来计算,此刻使用21.5mm 钢丝绳四股吊装10t 重设施,则单股受力约为2500kg ,可计算安全系数为,
知足要求。
钢丝绳起重量
表2—2 常用钢丝绳破断拉力表表2—2 常用钢丝绳破断拉力表钻井用钢丝绳安全系数表表2—1 钻井用钢丝绳安全系数表钢丝绳的许用拉力计算方法起重机钢丝绳的许用拉力计算公式 P=Sb/K式中:P—钢丝绳许用拉力,公斤力Sb—钢丝绳的破断拉力,公斤力K—钢丝绳的安全系数 Sb和K可查表取得例;有一直径为30毫米钢绳6×37+1;钢丝的抗拉强度为185公斤力/毫米2,用它来起吊设备,使用性质为机动中型问:钢绳允许起吊多少重量?解:查钢丝绳安全系数表K=5.5,,破断拉力Sb=63150×0.82=51780公斤力,则允许吊重为 P=Sb/K=51780/5.5=9420公斤力,对于结构为绳6×19+1强度极限为140~155公斤力/毫米2。
钢丝绳的破断拉力可用下列公式近似计算,破断拉力Sb=45d2 d—绳径以毫米代入,如果去安全系数K=5时,可用下式计算许用拉力,许用拉力P=0.01 d2 d—绳径以毫米代入,许用拉力T上一篇:对《起重机械安全技术监察规程-桥式起重机》实施的问题说明下一篇:在用起重机械定期检验周期额定拉力=直径x直径(cm)6 L- b5 T. }) [2 ?2 Q) g( n! t最大的起重机论坛-吊车论坛-吊装论坛 The largest crane site例如14的=1.4x1.4=1.96T 3 T% s; m3 x6 Q: ?3 \9 B/ I最大的起重机论坛-吊车论坛-吊装论坛 The largest crane site破断拉力是该数值的4~6倍,我的建议一般不要超过该数值的2倍。
起吊重物或穿滑轮使用,应选择比较柔软、易弯曲的6×37 或6×61 的钢丝绳。
2.作为缆风绳或拖拉绳可选用6×19 钢丝绳。
3.根据钢丝绳受力的大小,按照钢丝绳许用拉力,选择合适的直径。
4.选择后的钢丝绳要进行验算。
验算公式:S≦F/n S――钢丝绳最大工作静拉力F――所选钢丝绳的破断拉力n――钢丝绳的安全系数(缆风绳n=3.5、吊挂捆绑和起升机构n=5~7)1.断丝的性质和数量 6 股钢丝绳断丝主要发生在外表,钢丝绳表面可见断丝总数超过表中规定应报废。
2021年常用钢丝绳型号(图)、直径、拉力表
钢丝绳6*37欧阳光明(2021.03.07)(执行标准:GB/T 20118-2006)Main Applications:Various equipment for derricking,lfting and drawing 钢丝绳6*37的主要用途:各种起重、提升和牵引设备钢丝绳6*37的最小钢丝绳破断拉力总和=钢丝绳最小破断拉力×1.226(纤维芯)或×1.321(钢芯)钢丝绳6*19(执行标准:GB/T 20118-2006)Main Applications:Various equipment for derricking,lfting and drawing 钢丝绳6*19的主要用途:各种起重、提升和牵引设备钢丝绳6*19的最小钢丝绳破断拉力总和=钢丝绳最小破断拉力×1.249(纤维芯)或×1.336(钢芯)钢丝绳6*19S、6*19W(执行标准:GB/T 20118-2006)Main Applications:Various equipment for hoisting, derricking,lifting, towing, port load and unload, blast furnace hoisting and oil well drilling.The rope with wire core can be used under the shock load, heated and squeezed conditions.钢丝绳6*19S、6*19W的主要用途:各种起重、提升和牵引设备、港口装卸、高炉卷扬、石油钻井、金属芯绳适用于冲击负荷,受热和受挤压条件下。
钢丝绳6*19S、6*19W的最小钢丝绳破断拉力总和=钢丝绳最小破断拉力×1.134(纤维芯)或1.214(钢芯)。
钢丝绳6*29Fi、6*25Fi、6*26SW、6*31SW、6*36SW、6*37S(执行标准:GB/T 20118-2006)Main Appplications:Various eqmuipment for derricking, lifting and drawing;the rope with wire core can be used under the shock load,heated and squeezed conditions such as electric shares.钢丝绳6*29Fi、6*25Fi、6*26SW、6*31SW、6*36SW、6*37S的主要用途:各种起重、提升和牵引设备,金属绳芯适用于负荷、受热和受挤压条件下,例如:电铲。