楼mm厚板计算手册新增底板抗冲切计算

合集下载

楼mm厚板计算书增底板抗冲切计算

楼mm厚板计算书增底板抗冲切计算

150mn 厚板模板支撑计算书(2) 楼板底模板验算第一层龙骨(次楞)间距L=350mm 计算跨数 W=bh 2 /6= 1000X 182/6=54000mm 3,I=bh 3/12= 1000X 18 3/12=486000mm 4。

1 )内力及挠度计算a. ①+②+③+④荷载支座弯矩系数 K=-0.105 , M=Kq 1L 2 =-0.105 X 8.38 X 350 2=-107788N • mm剪力系数 K V =0.606 , V 1=K V q 1L=0.606X8.38X350=1777Nb. ①+②+③荷载支座弯矩系数 K=-0.105 , M 2=Kq 2L 2=-0.105 X 4.88 X 350 2=-62769N • mm跨中弯矩系数 如0.078 , M=Kq 2L 2=0.078 X 4.88 X 350 2=46628N • mm剪力系数 K V =0.606 ,V 2=K V q 2L=0.606 X4.88 X 350=1035N挠度系数 K u =0.644, u 2=K u q ‘2L 4/(100EI)= 0.644 X (4.88/1.2) X 350 4/(100 X 6000X 486000)=0.13 mmc. 施工人员及施工设备荷载按 2.50kN (按作用在边跨跨中计算)计算荷载 P=1.4 X 2.50=3.50 kN , 计算简图如下图所示。

跨中弯矩系数 如0.200 , M=K M X PL=0.200 X 3.50 X 1000X 350=245000 N • mm支座弯矩系数 K=-0.100 , M 5=K M X PL=-0.100 X 3.50 X 1000X 350= -122500N • mm剪力系数 K V =0.600 ,V 3=K V P=0.600X3.50=2.10 kN挠度系数 K u =1.456 ,u 3=K u P ,L 3/(100EI)= 1.456X(3.50/1.4) X1000X350 3/(100 X6000X486000)=0.54 mm2) 抗弯强度验算M=-107788N • mm M + M=-185269N • mm M+ M 4=291628N • mm 比较 M 1、M 2+M 5、M 3+M 4 取其绝对值大的作为抗弯强度验算的弯矩。

楼板抗冲切验算公式

楼板抗冲切验算公式

楼板抗冲切验算公式楼板抗冲切验算是建筑工程设计中非常重要的一项计算工作,它用于确定楼板在使用过程中是否能够承受外部冲击力的作用而不发生破坏。

在建设楼房、桥梁等工程中,正确进行抗冲切验算是确保结构安全可靠的关键之一。

楼板抗冲切验算的公式是根据材料力学原理和设计规范推导得出的,它可以分为静力法和动力法两种计算方法。

静力法是指根据建筑物重力荷载和冲击荷载的大小,通过计算楼板的内力状态来判断其抗冲切性能。

具体的公式为:抗冲切力=冲击力/抗冲切系数。

其中,抗冲切系数是根据楼板材料的特性和结构形式来确定的一个值,它代表了楼板在抵御冲击力时的能力。

动力法是指利用振动力学理论来计算楼板的抗冲切性能。

在这种方法中,首先要确定楼板的固有频率和振型,然后根据冲击力的频率和幅值,通过计算叠加法确定楼板的抗冲切力。

这种方法通常适用于大跨度楼板和地震区域的建筑设计。

在进行楼板抗冲切验算时,需要考虑多种因素,如楼板的几何尺寸、材料强度和刚度、冲击荷载的性质和作用位置等。

同时,还需要参考相关的设计规范和要求,确保计算结果符合安全性和可靠性的要求。

为了保证抗冲切验算的准确性和可靠性,建议在设计过程中采用一些有效的措施。

首先,要对楼板的冲击荷载进行合理的估计和分析,考虑到可能出现的不同工况和条件。

其次,要选择合适的材料和结构形式,确保楼板具有足够的抗冲切能力。

最后,要进行全面的计算和分析,考虑不同因素的相互作用和影响,确保楼板的设计符合工程实际需求。

总之,楼板抗冲切验算是建筑工程设计中一项重要而复杂的计算工作。

仅仅依靠公式计算是不够的,还需要考虑多种因素和采取有效的措施,确保抗冲切验算的准确性和可靠性。

只有在设计阶段充分考虑和满足抗冲切性能要求,才能保证建筑物在使用过程中的安全性和稳定性,为人们的生活和工作提供可靠的保障。

筏板基础计算书

筏板基础计算书

1 * 平板基础的内筒进行抗冲切和抗剪计算结果*说明:1.本结果是对平板基础的内筒进行抗冲切和抗剪计算2.计算依据是GB50007-2011的8.4.8和8.4.103.内筒外边界由程序使用者指定4.土反力按筏板平均反力确定筏板参数:筏板厚度h= 600.mm 保护层厚度a0=75.mm截面有效高度h0= 525.mm 混凝土强度等级C30.0最大荷载组load: 7筏板内荷载= 5550.0 kN 筏板底面积= 15.910 m2 平均基底反力= 348.8kPa平板基础的内筒抗冲切验算:内筒最大荷载Nmax= 5550.0kN 破坏面平均周长Um= 15.900m冲切锥体底面积= 20.160 m2 冲切力Fl= -1482.6kNFl/Um*h0=-177.6055<0.7*Bhp*ft/ita=802.4189平板基础的内筒抗剪验算:内筒外H0处边长= 18.00m 冲切锥体底面积= 20.16m2单位长度剪力Vs= -82.36kN/mVs=-82.3646<0.7*Bhs*ft*h0=526.5875*结束*2* 平板基础的内筒进行抗冲切和抗剪计算结果*SS说明:1.本结果是对平板基础的内筒进行抗冲切和抗剪计算2.计算依据是GB50007-2011的8.4.8和8.4.103.内筒外边界由程序使用者指定4.土反力按筏板平均反力确定筏板参数:筏板厚度h= 600.mm 保护层厚度a0=75.mm截面有效高度h0= 525.mm 混凝土强度等级C30.0最大荷载组load: 7筏板内荷载= 4514.3 kN 筏板底面积= 13.775 m2 平均基底反力= 327.7kPa 平板基础的内筒抗冲切验算:内筒最大荷载Nmax= 4514.3kN 破坏面平均周长Um= 14.910m冲切锥体底面积= 17.778 m2 冲切力Fl= -1311.7kNFl/Um*h0=-167.5640<0.7*Bhp*ft/ita=802.4189平板基础的内筒抗剪验算:内筒外H0处边长= 17.01m 冲切锥体底面积= 17.78m2单位长度剪力Vs= -77.11kN/mVs=-77.1097<0.7*Bhs*ft*h0=526.5875*结束*。

3#楼150mm厚板计算手册(新增底板抗冲切计算)

3#楼150mm厚板计算手册(新增底板抗冲切计算)

精心整理150mm厚板模板支撑计算书1.计算参数结构板厚150mm,层高9.65m,结构表面考虑隐蔽;模板材料为:夹板底模厚度18mm;板材弹性模量E=6000N/mm2,枋材弹性模量E=9000N/mm2,抗弯强度f m=13.00N/mm2,顺纹抗剪强度fv=1.40N/mm2;支撑采用Φ48×3.0mm钢管:横向间距1000mm,纵向间距1000mm,支撑立杆的步距h=1.50m;立杆伸出顶层水平杆中心线至支撑点的长度a=150mm;钢管直径48mm,壁厚3.0mm,截面积4.24cm2,回转半径i=1.59cm;钢材弹性模量E=206000N/mm2,抗弯强度f=205.00N/mm2,抗剪强度fv=120.00N/mm2。

2.楼板底模验算(1)底模及支架荷载计算荷载类型标准值单位计算宽度(m)板厚(m)①底模自重0.30kN/m2×1.0×1.2=0.36kN/m②砼自重24.00kN/m3③钢筋荷载1.10kN/m3④施工人员及施工设备荷载2.50kN/m2底模和支架承载力计算组合①+②+③+④q1(2第一层龙骨18mm,板模宽度=1000mmW=bh2/6=3/12=486000mm4。

1a.2=-107788N·mm剪力系数K Vb.2=-62769N·mm2=46628N·mm剪力系数K V=0.606,V2=K V q2L=0.606×4.88×350=1035N挠度系数Kυ=0.644,υ2=Kυq,2L4/(100EI)=0.644×(4.88/1.2)×3504/(100×6000×486000)=0.13mm c.施工人员及施工设备荷载按2.50kN(按作用在边跨跨中计算)计算荷载P=1.4×2.50=3.50kN,计算简图如下图所示。

跨中弯矩系数K M=0.200,M4=K M×PL=0.200×3.50×1000×350=245000N·mm支座弯矩系数K M=-0.100,M5=K M×PL=-0.100×3.50×1000×350=-122500N·mm剪力系数K V=0.600,V3=K V P=0.600×3.50=2.10kN挠度系数Kυ=1.456,υ3=KυP,L3/(100EI)=1.456×(3.50/1.4)×1000×3503/(100×6000×486000)=0.54mmM 1=-107788N ·mm ,M 2+M 5=-185269N ·mm ,M 3+M 4=291628N ·mm比较M 1、M 2+M 5、M 3+M 4,取其绝对值大的作为抗弯强度验算的弯矩。

筏基底板冲切计算计算书完整版

筏基底板冲切计算计算书完整版

ln1(m) ln2(m) p(kPa) h(mm) as(mm) h0=h-as ft
8
8
120
350
55
295
1.57
4.底板冲 切高度计 算:
h<=800 因为: 所以:
b= hp 1
(GB5000 7-2002第 8.2.7条)
当底板区 格为矩形 双向板 时,底板 受冲切所 需的厚度
h0:
1.计算依 据:规范 《建筑地 基基础设 计规范》 GB50007 -2002第 8.4.5条
2.计算简 图:
筏板基础底板冲切、剪切计算
项目名称:
回目录
p— —相应于 荷载效应 基本组合 的地基土 平均净反 力设计值
ln1,ln2— —计算板 格的长边 和短边的 净长度
3.输入条 件: 混凝土C 35
b h =(800/ )1/4
hs
0
式8.4.53右侧 为:
受剪阴影 部分面积 为:
=1
(本式中 因h0<800 故h0为: 800 )
(GB5000 7-2002式
8.4.5-4)
2807.945 kN
(2*ln2ln12*h0)*(ln 1-2*h0)/4 = 13.7 m2
VS = p?阴影部分面积= 1647.2 kN
OK! 满足式8.4.5-3要求
(ln1+ ln2) -
(l
n1+l
n2)2
-
p
l l 4p n1 n2
+ 0.7 b
f
h0 =
hp t
4
OK! 底
板厚度
(GB5000 7-2002式 8.4.5-2)

楼板抗冲切验算公式

楼板抗冲切验算公式

楼板抗冲切验算公式
楼板抗冲切验算公式是用于确定楼板的抗冲切能力的一种计算公式。

楼板作为建筑结构中的平面构件,承担着承载荷载和传递荷载的重要作用。

在设计楼板时,为了确保其在受到冲切力作用时不发生失稳和破坏,需要进行相应的验算。

抗冲切验算是通过计算楼板的抗冲切承载力与冲切力之间的关系来评估楼板的稳定性。

一般情况下,楼板受到的冲切力是由使用荷载和活载引起的。

为了满足结构的安全要求,需要确保楼板的抗冲切承载力大于受到的冲切力。

根据国家标准和规范,楼板抗冲切验算公式可以采用以下形式:
V = K × Q
其中,V表示楼板的抗冲切承载力,K为冲切系数,Q为受到的冲切力。

冲切系数K是通过研究得出的经验值,根据不同的楼板形式和材料特性有所差异。

冲切力Q可以根据具体的荷载计算公式进行确定,包括使用荷载和活载等。

需要注意的是,楼板抗冲切验算公式仅适用于规范范围内的常规情况,对于特殊情况或复杂结构的楼板设计,可能需要采用更复杂的计算方法。

因此,在实际设计中,应按照相关规范和标准进行具体的计算与验算。

总之,楼板抗冲切验算公式是一种用于评估楼板稳定性的计算方法,通过计算抗冲切承载力与冲切力之间的关系来确保楼板在受力时不发生失稳和破坏。

在实际设计中,需要根据具体情况选择合适的公式并遵循相关规范和标准进行计算。

底板抗冲切计算

底板抗冲切计算

底板柱帽抗冲切验算:(1)柱对底板抗冲切验算E轴交6.轴处柱,平时荷载下冲切已验算完毕,现验算人防工况:恒荷载作用下内力标准值:5217KN人防荷载作用下内力标准值:2888KN人防冲切荷载设计值:F l=1.1×(1.2×5217+2888-3*3*100)=9073KN柱帽厚度1100:抗冲切验算:人防:0.7βh f td u m h0=0.7*0.975*1.5*1.43*7400*1050=11375KN满足要求(2)柱对底板抗冲切验算K轴交2.轴处柱,平时荷载下冲切已验算完毕,现验算人防工况:恒荷载作用下内力标准值:2333KN人防荷载作用下内力标准值:2811KN人防冲切荷载设计值:F l=1.1×(1.2×2333+2811-2.3*2.3*100)=5589KN 柱帽厚度800:抗冲切验算:人防:0.7βh f td u m h0=0.7*1.0*1.5*1.43*5800*750=6531KN满足要求(3)柱对底板抗冲切验算U轴交6.轴处柱,平时荷载下冲切已验算完毕,现验算人防工况:恒荷载作用下内力标准值:4325KN人防荷载作用下内力标准值:4055KN人防冲切荷载设计值:F l=1.1×(1.2×4325+4055-3*3*100)=8228KN柱帽厚度1100:抗冲切验算:人防:0.7βh f td u m h0=0.7*0.975*1.5*1.43*7400*1050=11375KN满足要求(4)柱对底板抗冲切验算21轴交Q.轴处柱恒荷载作用下内力标准值:4032KN人防荷载作用下内力标准值:4453KN人防冲切荷载设计值:F l=1.1×(1.2×4032+4453-2.6*2.6*100)=9477KN 平时冲切荷载设计值:F l=1.1×(6256-2.6*2.6*100)=6138 KN柱帽厚度1000:抗冲切验算:人防:0.7βh f td u m h0=0.7*0.983*1.5*1.43*7000*950=9815KN平时:0.7βh f t u m h0=0.7*0.983*1.43*7000*950=6543KN 满足要求底板对柱,柱帽抗冲切验算:水浮力及底板自重标准值:67KN/m2人防荷载标准值:50KN/m2a)底板对柱受荷面积:8.4*8.8-2.6*2.6=67.2m2底板人防冲切荷载设计值:F l=1.1×(1.2×67 +50)x67.2=9639KN 底板平时冲切荷载设计值:F l=1.35x67x67.2=6078KN满足要求b)底板对柱帽受荷面积:8.4*8.8-3*3=64.9m2底板人防冲切荷载设计值:F l=1.1×(1.2×67 +50)x64.9=9309KN 底板平时冲切荷载设计值:F l=1.35x67x64.9=5870KN底板厚度600:抗冲切验算:人防:0.7βh f td u m h0=0.7*1.5*1.43*14200*550=11726KN平时:0.7βh f t u m h0=0.7*1.43*14200*550=7818KN满足要求。

楼板抗冲切验算公式

楼板抗冲切验算公式

楼板抗冲切验算公式 楼板抗冲切验算公式是建筑工程中用于计算楼板在地震或风荷载作用下的抗冲切能力的一种方法。

本文将详细介绍楼板抗冲切验算的步骤和相关计算公式,并通过具体例子进行说明,以帮助读者更好地理解和应用。

1. 楼板抗冲切验算概述 楼板抗冲切验算是指对于楼板在地震或风荷载作用下,其与面板之间的连接是否能够承受弹性载荷而不发生破坏进行的一项重要工作。

通过设计合适的楼板抗冲切能力,可以确保建筑结构在地震或风灾中具有足够的稳定性和安全性。

2. 楼板抗冲切验算步骤楼板抗冲切验算一般包括以下几个步骤: (1) 确定体系刚度:根据楼板设计结构,计算出其刚度参数,包括刚度矩阵和刚度系数等; (2) 定义荷载组合:确定地震和风荷载的设计组合,并确定设计基准地震烈度或风荷载参数; (3) 计算冲切力:根据刚度和荷载组合,计算楼板所受到的冲切力,包括水平方向的冲切力和竖向的冲切力; (4) 检查抗冲切能力:根据设计要求,比较计算得到的冲切力与楼板和面板之间的连接的抗冲切能力; (5) 调整设计:根据验算结果,如冲切力超过抗冲切能力,在设计中进行调整,如加固连接或增加楼板的厚度等。

楼板抗冲切验算公式是通过计算冲切力和抗冲切能力之间的关系来判断楼板是否满足设计要求。

下面是两个常用的楼板抗冲切验算公式的介绍: (1) 冲切力计算公式:根据楼板的荷载和刚度参数,计算出楼板所受到的冲切力。

冲切力可以分为水平方向的冲切力和竖向的冲切力。

水平方向的冲切力一般通过楼板质量乘以加速度来计算,而竖向的冲切力一般通过楼板质量乘以楼板与面板之间的相对位移来计算。

(2) 抗冲切能力计算公式:根据楼板和面板之间的连接方式和承载能力,计算出连接的抗冲切能力。

抗冲切能力可以通过连接的抗剪强度和承载能力来判断。

4. 例子说明 为了更好地理解和应用楼板抗冲切验算公式,我们以某住宅楼的楼板设计为例进行说明。

首先,我们根据楼板结构参数计算出其刚度矩阵和刚度系数。

筏板基础底板冲切、剪切计算表格

筏板基础底板冲切、剪切计算表格

8
8
200
500
55
445 #VALUE!
4.底板冲 切高度计 算:
h<=800 所以: 因为:
当底板区 格为矩形 双向板 时,底板 受冲切所 需的厚度 h0:
b= hp 1
(GB5000 7-2002第 8.2.7条)
(ln1+ ln2) -
(l
n1+l
n2)2
-
p
l l 4p n1 n2
+ 0.7 b
1.计算依 据:规范 《建筑地 基基础设 计规范》 GB50007 -2002第 8.4.5条
2.计算简 图:
筏板基础底板冲切、剪切计算
项目名称:
p— —相应于 荷载效应 基本组合 的地基土 平均净反 力设计值
ln1,ln2— —计算板 格的长边 和短边的 净长度
3.输入条 件: 混凝土C 35
ln1(m) ln2(m) p(kPa) h(mm) as(mm) h0=h-as ft
b h = (800/ )1/ 4
hs
0
式8.4.53右侧 为:
受剪阴影 部分面积 为:
=1
(本式中 因h0<800 故h0为: 800 )
(GB5000 7-2002式
8.4.5-4)
kN #VALUE!
(2*ln2ln12*h0)*(ln 1-2*h0)/4 = 12.6 m2
VS = p?阴影部分面积= 2527.6 kN
f
h0 =

hp t
4
= ######## mm
#VALUE!
(GB5000 7-2002式 8.4.5-2)
5.底板斜 截面受剪 承载力验 算:

板冲切计算表格

板冲切计算表格
mm冲切计算来自ZD1设计时间:
2015年6月25日
基本数据输入 截面高度= 受拉保护层厚度+d/2= 受压保护层厚度+d/2= 混凝土强度等级C 受拉钢筋强度fy= 箍筋钢筋强度fyv= 纵向钢筋直径φ = 700 35 35 30 360 360 16 mm mm mm N/mm² N/mm² N/mm² mm 混凝土强度fc= 混凝土强度ft= 截面有效高度h0= 截面高度影响系数β h= 临界截面周长um= 长短边之比影响系数β s= 板柱结构中的系数α s= η 1=0.4+1.2/β s= η 2=0.5+α sh0/4um= 不配置箍筋或弯起钢筋的板的计算 局部荷载设计值或集中反力设计值 Fl= 0.7β hftη umh0= 配置箍筋或弯起钢筋时,受冲切截面应符合下列条件: 1.05ftη umh0= 1 当配置箍筋时 Asu=(Fl-0.35ftη umh0)/(0.8fyv)= 2428 mm² 2368 kN 截面符合条件! 1488.5 1578 kN kN 可以! 14.3 1.43 657 1.00 2400 2 40 1.00 3.24 N/mm² N/mm² mm

楼板抗冲切验算公式(一)

楼板抗冲切验算公式(一)

楼板抗冲切验算公式(一)楼板抗冲切验算公式1. 引言在建筑设计和结构计算中,楼板抗冲切验算是非常重要的一项工作。

楼板抗冲切能力的验算结果直接影响建筑结构的安全性和耐久性。

本文将介绍一些常见的楼板抗冲切验算公式,并以示例说明每个公式的应用。

2. 列举相关公式以下是一些常用的楼板抗冲切验算公式:楼板总抗冲切力计算公式楼板总抗冲切力是指楼板受到的全部抗冲切力的总和。

通常根据楼板尺寸、荷载情况和材料特性来计算。

公式示例:楼板总抗冲切力 = 荷载Q × 楼板面积其中,Q是楼板荷载,单位为kN/m²;楼板面积单位为m²。

楼板楔形预应力计算公式楼板楔形预应力是指通过楼板预应力体系产生的预压力,用于增加楼板的抗冲切能力。

公式示例:楼板楔形预应力= K × ∑(P × a)其中,K是楼板的系数;P是预应力锚具的预应力值;a是预应力锚具的位置。

∑表示锚具的累加求和。

楼板混凝土自重计算公式楼板混凝土自重是指楼板自身的重量,也是抗冲切的重要因素之一。

公式示例:楼板混凝土自重 = 混凝土体积 × 混凝土密度 × g其中,混凝土体积单位为m³;混凝土密度单位为kg/m³;g是重力加速度,取/s²。

3. 举例解释说明假设一栋楼的楼板荷载为10kN/m²,楼板面积为200m²,荷载均匀分布在整个楼板上。

根据公式,可以计算出楼板总抗冲切力:楼板总抗冲切力 = 10kN/m² × 200m² = 2000kN这个结果表示楼板受到的总抗冲切力为2000kN。

假设楼板采用楔形预应力体系,预应力锚具的预应力值为50kN,预应力锚具的位置有4个,分别为、、、。

根据公式,可以计算出楼板楔形预应力:楼板楔形预应力 = K × (50kN × + 50kN × + 50kN × + 5 0kN × )这个结果表示楼板通过楔形预应力体系产生的预压力。

120mm厚板厚支撑体系计算书

120mm厚板厚支撑体系计算书

板模板(扣件式)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《混凝土结构设计规范》GB50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计规范》GB 50017-2003一、工程属性设计简图如下:模板设计平面图模板设计剖面图(楼板长向)模板设计剖面图(楼板宽向)四、面板验算的规定,另据现实,楼板面板应搁置在梁侧模板上,因此本例以简支梁,取1m单位宽度计算。

计算简图如下:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm41、强度验算q1=0.9max[1.2(G1k+ (G3k+G2k)×h)+1.4Q1k,1.35(G1k+ (G3k+G2k)×h)+1.4×0.7Q1k]×b=0.9max[1.2×(0.1+(1.1+24)×0.12)+1.4×2.5,1.35×(0.1+(1.1+24)×0.12)+1.4×0.7×2.5] ×1=6.51kN/mq2=0.9×1.2×G1k×b=0.9×1.2×0.1×1=0.11kN/mp=0.9×1.4×Q1K=0.9×1.4×2.5=3.15kNM max=max[q1l2/8,q2l2/8+pl/4]=max[6.51×0.22/8,0.11×0.22/8+3.15×0.2/4]= 0.16kN〃mσ=M max/W=0.16×106/37500=4.21N/mm2≤[f]=15N/mm2满足要求!2、挠度验算q=(G1k+(G3k+G2k)×h)×b=(0.1+(1.1+24)×0.12)×1=3.11kN/mν=5ql 4/(384EI)=5×3.11×2004/(384×10000×281250)=0.02mm ≤[ν]=l/400=200/400=0.5mm 满足要求! 五、小梁验算 小梁类型方木 小梁材料规格(mm) 60×80 小梁抗弯强度设计值[f](N/mm 2)15.44小梁抗剪强度设计值[τ](N/mm 2)1.78小梁弹性模量E(N/mm 2) 9350 小梁截面抵抗矩W(cm 3) 64小梁截面惯性矩I(cm 4) 256因[L/l a ]取整=[8000/900]取整=8,按四等跨连续梁计算,又因小梁较大悬挑长度为200mm ,因此需进行最不利组合,计算简图如下:1、强度验算q 1=0.9max[1.2(G 1k +(G 3k +G 2k )×h)+1.4Q 1k ,1.35(G 1k +(G 3k +G 2k )×h)+1.4×0.7Q 1k ]×b=0.9×max[1.2×(0.3+(1.1+24)×0.12)+1.4×2.5,1.35×(0.3+(1.1+24)×0.12)+1.4×0.7×2.5]×0.2=1.35kN/m因此,q1静=0.9×1.2(G1k+(G3k+G2k)×h)×b=0.9×1.2×(0.3+(1.1+24)×0.12)×0.2=0.72kN/mq1活=0.9×1.4×Q1k×b=0.9×1.4×2.5×0.2=0.63kN/mM1=0.107q1静L2+0.121q1活L2=0.107×0.72×0.92+0.121×0.63×0.92=0.12kN〃mq2=0.9×1.2×G1k×b=0.9×1.2×0.3×0.2=0.06kN/mp=0.9×1.4×Q1k=0.9×1.4×2.5=3.15kNM2=max[0.077q2L2+0.21pL,0.107q2L2+0.181pL]=max[0.077×0.06×0.92+0.21×3.15×0.9,0.107×0.06×0.92+0.181×3.15×0.9]=0.6kN〃mM3=max[q1L12/2,q2L12/2+pL1]=max[1.35×0.22/2,0.06×0.22/2+3.15×0.2]=0.63kN〃mM max=max[M1,M2,M3]=max[0.12,0.6,0.63]=0.63kN〃m σ=M max/W=0.63×106/64000=9.86N/mm2≤[f]=15.44N/mm2满足要求!2、抗剪验算V1=0.607q1静L+0.62q1活L=0.607×0.72×0.9+0.62×0.63×0.9=0.74kNV2=0.607q2L+0.681p=0.607×0.06×0.9+0.681×3.15=2.18kN V3=max[q1L1,q2L1+p]=max[1.35×0.2,0.06×0.2+3.15]=3.16kN V max=max[V1,V2,V3]=max[0.74,2.18,3.16]=3.16kN τmax=3V max/(2bh0)=3×3.16×1000/(2×80×60)=0.99N/mm2≤[τ]=1.78N/mm2满足要求!3、挠度验算q=(G1k+(G3k+G2k)×h)×b=(0.3+(24+1.1)×0.12)×0.2=0.66kN/m 跨中νmax=0.632qL4/(100EI)=0.632×0.66×9004/(100×9350×2560000)=0.11mm≤[ν]=l/400=900/400=2.25mm悬臂端νmax=qL4/(8EI)=0.66×2004/(8×9350×2560000)=0.01mm ≤[ν]=l1/400=200/400=0.5mm满足要求!六、主梁验算Q1k=1.5kN/m2q1=0.9max[1.2(G1k+ (G3k+G2k)×h)+1.4Q1k,1.35(G1k+(G3k+G2k)×h)+1.4×0.7Q1k]×b=0.9max[1.2×(0.5+(1.1+24)×0.12)+1.4×1.5,1.35×(0.5+(1.1+24)×0.12)+1.4×0.7×1.5]×0.2=1.14kN/mq1静=0.9×1.2(G1k+ (G3k+G2k)×h)×b=0.9×1.2×(0.5+(1.1+24)×0.12)×0.2=0.76kN/mq1活=0.9×1.4×Q1k×b=0.9×1.4×1.5×0.2=0.38kN/mq2=(G1k+ (G3k+G2k)×h)×b=(0.5+(1.1+24)×0.12)×0.2=0.7kN/m承载能力极限状态按四跨连续梁,R max=(1.143q1静+1.223q1活)L=1.143×0.76×0.9+1.223×0.38×0.9=1.2kN按悬臂梁,R1=q1l=1.14×0.2=0.23kNR=max[R max,R1]=1.2kN;正常使用极限状态按四跨连续梁,R max=1.143q2L=1.143×0.7×0.9=0.72kN 按悬臂梁,R1=q2l=0.7×0.2=0.14kNR=max[R max,R1]=0.72kN;2、抗弯验算计算简图如下:主梁弯矩图(kN〃m)M max=0.45kN〃mσ=M max/W=0.45×106/5080=88.69N/mm2≤[f]=205N/mm2满足要求!3、抗剪验算主梁剪力图(kN)V max=2.9kNτmax=2V max/A=2×2.9×1000/489=11.85N/mm2≤[τ]=125N/mm2 满足要求!4、挠度验算主梁变形图(mm)νmax=0.37mm跨中νmax=0.37mm≤[ν]=900/400=2.25mm悬挑段νmax=0.1mm≤[ν]=200/400=0.5mm满足要求!七、立柱验算立杆稳定性计算依据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011剪刀撑设置加强型立杆顶部步距h d(mm) 1500 立杆伸出顶层水平杆中心线至支撑点的长度a(mm)200顶部立杆计算长度系数μ1 1.386 非顶部立杆计算长度系数μ21.755钢管类型Ф48×3 立柱截面面积A(mm2) 424立柱截面回转半径i(mm)15.9 立柱截面抵抗矩W(cm3) 4.49抗压强度设计值[f](N/mm2)2051、长细比验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(1500+2×200)=2633.4mm 非顶部立杆段:l02=kμ2h =1×1.755×1800=3159mmλ=l0/i=3159/15.9=198.68≤[λ]=210长细比满足要求!2、立柱稳定性验算顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(1500+2×200)=3041.577mmλ1=l01/i=3041.577/15.9=191.294,查表得,φ1=0.197 M w=0.92×1.4ωk l a h2/10=0.92×1.4×0.18×0.9×1.82/10=0.06kN〃mN w=0.9[1.2ΣN Gik+0.9×1.4Σ(N Qik+M w/l b)]=0.9×[1.2×(0.5+(24+1.1)×0.12)+0.9×1.4×1]×0.9×0.9+0.92×1.4×0.06/0.9=4.07kNf= N w/(φA)+ M w/W=4065.83/(0.2×424)+0.06×106/4490=61.93N/mm2≤[f]=205N/mm2满足要求!非顶部立杆段:l02=kμ2h =1.155×1.755×1800=3648.645mm λ2=l02/i=3648.645/15.9=229.475,查表得,φ2=0.139 非顶部立杆段:l02=kμ2h =1.155×1.755×1800=3648.645mm λ2=l02/i=3648.645/15.9=229.475,查表得,φ2=0.139 M w=0.92×1.4ωk l a h2/10=0.92×1.4×0.18×0.9×1.82/10=0.06kN〃mN w=0.9[1.2ΣN Gik+0.9×1.4Σ(N Qik+M w/l b)]=0.9×[1.2×(0.75+(24+1.1)×0.12)+0.9×1.4×1]×0.9×0.9+0.92×1.4×0.06/0.9=4.28kNf= N w/(φA)+ M w/W=4284.53/(0.14×424)+0.06×106/4490=85.95N/mm2≤[f]=205N/mm2满足要求!八、可调托座验算满足要求!九、立柱地基基础验算f 42.85kPa≤f ak=70kPa满足要求!。

地下室底板抗水板计算(2013.10.20)(添加了冲切和剪切)

地下室底板抗水板计算(2013.10.20)(添加了冲切和剪切)

Mx/(0 .9fyh
mm2
实配φ 14 @ 150
实配 As = 1026 mm2
2.裂缝验算:
ho= 423 mm 68. 4/( 最小配筋率 ρmin= 0.20%
实际配筋率 ρ= 0.23%
499 mm2
满足要 求!
构件受力特征系数 αcr= 1.9
钢筋弹性模量 Es= 2.0E+05 N/mm2
50 mm 20 mm
混凝土强度标准值ftk= 2.01
混凝土强度设计值ft= 1.43
柱尺寸 a × b = 水
位 底板上300厚垫层重
0.6 × 340 KN/m2
水净反力准永久值 qj=
25 KN/m2
N/mm2 N/mm2
0.6 m
(扣除 向 (下 扣恒 除 向下恒
ho= 740 mm 420
.1/
1752.2 mm2
实配φ 20 @ 150
最小配筋率 ρmin= 0.20%
三.冲切计算:
㈠.承台边冲切计算:
截面有效高度
ho1= 391 mm
冲切锥计算截面的周长um=2
2*(
(A+ho1+B+ho1)=
2.7
截面高度影响系数
βh= 1.00
系数 βs= 系数η1=0.4+1.2/βs =
系数 αs=
2 0.
4+ 40
1.00
系数η2=0.5+αsho1/(4 um) =
最小配筋率 ρmin= 0.20%
实配 As = 1696 mm2
实际配筋率 ρ= 0.38%
1499.8 mm2
满足要 求!
2.裂缝验算:

800 mm厚板模板计算书

800 mm厚板模板计算书

800 mm厚板模板计算书(按根部最不利考虑)一、参数信息1.模板支架参数横向间距或排距(m):0.60;纵距(m):0.60;步距(m):1.50;立杆上端伸出至模板支撑点长度(m):0.20;模板支架搭设高度(m):3.60;采用的钢管(mm):Φ48×3.5 ;板底支撑连接方式:方木支撑;立杆承重连接方式:可调托座;2.荷载参数模板与木板自重(kN/m2):0.350;混凝土与钢筋自重(kN/m3):25.000;施工均布荷载标准值(kN/m2):2.500;3.材料参数面板采用胶合面板,厚度为18mm;板底支撑采用方木;面板弹性模量E(N/mm2):9000;面板抗弯强度设计值(N/mm2):13;木方弹性模量E(N/mm2):9000.000;木方抗弯强度设计值(N/mm2):13.000;木方抗剪强度设计值(N/mm2):1.400;木方的间隔距离(mm):300.000;木方的截面宽度(mm):80.00;木方的截面高度(mm):80.00;托梁材料为:钢管(单钢管) :Ф48×3.5;图2 楼板支撑架荷载计算单元二、模板面板计算模板面板为受弯构件,按三跨连续梁对面板进行验算其抗弯强度和刚度模板面板的截面惯性矩I和截面抵抗矩W分别为:W = 60×1.82/6 = 32.4 cm3;I = 60×1.83/12 = 29.16 cm4;模板面板的按照三跨连续梁计算。

面板计算简图1、荷载计算(1)静荷载为钢筋混凝土楼板和模板面板的自重(kN/m):q1 = 25×0.8×0.6+0.35×0.6 = 12.21 kN/m;(2)活荷载为施工人员及设备荷载(kN/m):q2 = 2.5×0.6= 1.5 kN/m;2、强度计算计算公式如下:M=0.1ql2其中:q=1.2×12.21+1.4×1.5= 16.752kN/m最大弯矩M=0.1×16.752×3002= 150768 N·mm;面板最大应力计算值σ =M/W= 150768/32400 = 4.653 N/mm2;面板的抗弯强度设计值[f]=13 N/mm2;面板的最大应力计算值为 4.653 N/mm2小于面板的抗弯强度设计值13 N/mm2,满足要求!3、挠度计算挠度计算公式为:ν=0.677ql4/(100EI)≤[ν]=l/250其中q =q1= 12.21kN/m面板最大挠度计算值ν=0.677×12.21×3004/(100×9000×29.16×104)=0.255 mm;面板最大允许挠度[ν]=300/ 250=1.2 mm;面板的最大挠度计算值0.255 mm 小于面板的最大允许挠度 1.2 mm,满足要求!三、模板支撑方木的计算方木按照两跨连续梁计算,截面惯性矩I和截面抵抗矩W 分别为:W=b×h2/6=8×8×8/6 = 85.33 cm3;I=b×h3/12=8×8×8×8/12 = 341.33 cm4;方木楞计算简图(mm)1.荷载的计算(1)静荷载为钢筋混凝土楼板和模板面板的自重(kN/m):q1= 25×0.3×0.8+0.35×0.3 = 6.105 kN/m ;(2)活荷载为施工人员及设备荷载(kN/m):q2 = 2.5×0.3 = 0.75 kN/m;2.强度验算计算公式如下:M=0.125ql2均布荷载q = 1.2 × q1+ 1.4 ×q2 = 1.2×6.105+1.4×0.75 = 8.376 kN/m;最大弯矩M = 0.125ql2 = 0.125×8.376×0.62 = 0.377 kN·m;方木最大应力计算值σ= M /W = 0.377×106/85333.33 = 4.417 N/mm2;方木的抗弯强度设计值[f]=13.000 N/mm2;方木的最大应力计算值为 4.417 N/mm2小于方木的抗弯强度设计值13 N/mm2,满足要求!3.抗剪验算截面抗剪强度必须满足:τ = 3V/2bh n< [τ]其中最大剪力: V= 0.625×8.376×0.6 = 3.141 kN;方木受剪应力计算值τ = 3 ×3.141×103/(2 ×80×80) =0.736 N/mm2;方木抗剪强度设计值[τ] = 1.4 N/mm2;方木的受剪应力计算值0.736 N/mm2小于方木的抗剪强度设计值1.4 N/mm2,满足要求!4.挠度验算计算公式如下:ν=0.521ql4/(100EI)≤[ν]=l/400均布荷载q = q1 = 6.105 kN/m;最大挠度计算值ν= 0.521×6.105×6004/(100×9000×3413333.333)= 0.134 mm;最大允许挠度[ν]=600/ 250=2.4 mm;方木的最大挠度计算值0.134 mm 小于方木的最大允许挠度 2.4 mm,满足要求!四、托梁材料计算托梁按照集中荷载作用下的三跨连续梁计算;托梁采用:钢管(单钢管) :Ф48×3.5;W=5.08 cm3;I=13.08 cm4;集中荷载P取纵向板底支撑传递力,P=5.026kN;托梁计算简图托梁计算弯矩图(kN·m)托梁计算变形图(mm)托梁计算剪力图(kN) 最大弯矩M max = 0.528 kN·m ;最大变形V max = 0.462 mm ;最大支座力Q max = 10.806 kN ;最大应力σ= 527788.537/5080 = 103.895 N/mm2;托梁的抗压强度设计值[f]=205 N/mm2;托梁的最大应力计算值103.895 N/mm2小于托梁的抗压强度设计值205 N/mm2,满足要求!托梁的最大挠度为0.462mm 小于600/150与10 mm,满足要求!五、模板支架立杆荷载设计值(轴力)作用于模板支架的荷载包括静荷载和活荷载。

筏板基础冲切计算实例

筏板基础冲切计算实例

平板式筏基的板厚应满足受冲切承载力的要求,其受冲切承载力按下公式计算:
U m=2(a+b)+2h o=2*(150+150)+2*450=2400mm
其中a.b分别为内柱的长和宽,取150mm;
筏板厚度取450mm;
= 0.7*1*1.43*2400*450/1.25
=864864N
=864.864kN
计算设备混凝土厚度考虑因素很多,如设备重量,地基承载力和压缩性,设备振动荷载,设备对沉降的要求等。

但主要考虑的还是前两项。

根据设备重量除地基承载力得出的底面边长,减去设备底面的边长,再除以2,就可得基础厚度。

(荷载扩散角,按45°考虑的)。

再考虑一定的安全系数就可以了。

当基础宽度大于3m或埋置深度大于0.5m时,从载荷试验或其它原位测试、经验值等方法确定的地基承载力特征值,尚应按下式修正:
fa=fak+ηbγ(b-3)+ηdγm(d-0.5)
式中
fa--修正后的地基承载力特征值;
fak--地基承载力特征值
ηb、ηd--基础宽度和埋深的地基承载力修正系数
γ--基础底面以下土的重度,地下水位以下取浮重度;
b--基础底面宽度(m),当基宽小于3m按3m取值,大于6m按6m取值;
γm--基础底面以上土的加权平均重度,地下水位以下取浮重度;
d--基础埋置深度(m),一般自室外地面标高算起。

在填方整平地区,可自填土地面标高算起,但填土在上部结构施工后完成时,应从天然地面标高算起。

对于地下室,如采用箱形基础或筏基时,基础埋置深度自室外地面标高算起;当采用独立基础或条形基础时,应从室内地面标高算起。

板厚承受 冲击力计算

板厚承受 冲击力计算

板厚承受冲击力计算板厚承受冲击力是工程设计和材料力学中一个重要的问题。

为了计算板厚所能承受的冲击力,可以从材料的强度和应变能出发进行分析。

首先,需要了解冲击力的概念。

冲击力是一种突然施加在物体上的力,其作用时间很短,通常很难预测和控制。

在实际设计中,冲击力可以由各种因素引起,例如车辆碰撞、爆炸、风暴等。

在计算板厚承受冲击力之前,需要首先确定冲击力的大小和方向。

对于不同的冲击力类型,可以采用不同的方法进行计算。

一种常用的方法是根据能量守恒原理进行计算。

能量守恒原理认为,冲击力产生的能量应该等于物体吸收的能量。

因此,可以通过计算吸收的能量来估计冲击力的大小。

具体而言,在计算板厚承受冲击力时,可以采用以下步骤:1. 确定冲击对象:首先需要确定受冲击的对象是板厚的哪一部分,例如板材的表面、边缘邻近区域等。

这将有助于确定冲击力的作用点和作用面积。

2. 计算冲击能量:需要根据冲击力的特性计算冲击能量。

对于均布冲击力,可以使用能量公式E=1/2mv^2来计算;对于局部冲击力,可以采用冲击力F乘以冲击距离d来计算冲击能量。

3. 估算吸收能量:根据板厚的材料强度和应变能,可以估算出板厚所能承受的冲击能量。

强度是指材料在受力时能够承受的最大应力,应变能是材料从未受力状态到达承受最大应力状态所增加的能量。

4. 判断板厚是否能够承受冲击力:比较冲击能量和估算的吸收能量。

如果冲击能量小于等于吸收能量,说明板厚足够承受该冲击力;如果冲击能量大于吸收能量,说明板厚可能会发生破坏。

需要注意的是,以上的计算方法只是一种简化的计算方式,实际情况会更为复杂。

在实际设计中,还需要考虑材料的韧性、板厚的几何形状、板材的支撑结构等因素。

此外,也需要根据具体的应用要求和标准进行计算和验证。

综上所述,计算板厚承受冲击力的方法是一个复杂的过程,需要考虑多个因素和参数。

通过能量守恒原理,可以估算出板厚所能承受的冲击能量,从而判断其是否能够承受给定的冲击力。

120mm厚板模板计算书

120mm厚板模板计算书

120mm厚板模板计算书一、参数信息1.模板支架参数横向间距或排距(m):1.00;纵距(m):1.00;步距(m):1.50;立杆上端伸出至模板支撑点长度(m):0.20;模板支架搭设高度(m):10.70;采用的钢管(mm):Φ48×3.2 ;板底支撑连接方式:方木支撑;立杆承重连接方式:可调托座;2.荷载参数模板与木板自重(kN/m2):0.500;混凝土与钢筋自重(kN/m3):25.500;施工均布荷载标准值(kN/m2):1.000;3.材料参数面板采用胶合面板,厚度为18mm;板底支撑采用方木;面板弹性模量E(N/mm2):9500;面板抗弯强度设计值(N/mm2):13;木方抗剪强度设计值(N/mm2):1.400;木方的间隔距离(mm):250.000;木方弹性模量E(N/mm2):9000.000;木方抗弯强度设计值(N/mm2):13.000;木方的截面宽度(mm):50.00;木方的截面高度(mm):100.00;托梁材料为:钢管(双钢管) :Ф48×3;4.楼板参数楼板的计算厚度(mm):120.00;图2 楼板支撑架荷载计算单元二、模板面板计算模板面板为受弯构件,按三跨连续梁对面板进行验算其抗弯强度和刚度 模板面板的截面惯性矩I 和截面抵抗矩W 分别为:W = 100×1.82/6 = 54 cm 3;I = 100×1.83/12 = 48.6 cm 4;模板面板的按照三跨连续梁计算。

面板计算简图1、荷载计算(1)静荷载为钢筋混凝土楼板和模板面板的自重(kN/m):q1 = 25.5×0.12×1+0.5×1 = 3.56 kN/m;(2)活荷载为施工人员及设备荷载(kN/m):q2 = 1×1= 1 kN/m;2、强度计算计算公式如下:M=0.1ql2其中:q=1.2×3.56+1.4×1= 5.672kN/m最大弯矩M=0.1×5.672×2502= 35450 N·m;面板最大应力计算值σ =M/W= 35450/54000 = 0.656 N/mm2;面板的抗弯强度设计值[f]=13 N/mm2;面板的最大应力计算值为0.656 N/mm2小于面板的抗弯强度设计值13 N/mm2,满足要求!3、挠度计算挠度计算公式为ν=0.677ql4/(100EI)≤[ν]=l/250其中q =q1=3.56kN/m面板最大挠度计算值ν = 0.677×3.56×2504/(100×9500×48.6×104)=0.02 mm;面板最大允许挠度[ν]=250/ 250=1 mm;面板的最大挠度计算值0.02 mm 小于面板的最大允许挠度 1 mm,满足要求!三、模板支撑方木的计算方木按照三跨连续梁计算,截面惯性矩I和截面抵抗矩W分别为:W=b×h2/6=5×10×10/6 = 83.33 cm3;I=b×h3/12=5×10×10×10/12 = 416.67 cm4;方木楞计算简图1.荷载的计算(1)静荷载为钢筋混凝土楼板和模板面板的自重(kN/m):q1= 25.5×0.25×0.12+0.5×0.25 = 0.89 kN/m ;(2)活荷载为施工人员及设备荷载(kN/m):q2 = 1×0.25 = 0.25 kN/m;2.强度验算计算公式如下:M=0.1ql2均布荷载q = 1.2 × q1 + 1.4 ×q2 = 1.2×0.89+1.4×0.25 = 1.418 kN/m;最大弯矩M = 0.1ql2 = 0.1×1.418×12 = 0.142 kN·m;方木最大应力计算值σ= M /W = 0.142×106/83333.33 = 1.702 N/mm2;方木的抗弯强度设计值[f]=13.000 N/mm2;方木的最大应力计算值为 1.702 N/mm2小于方木的抗弯强度设计值13 N/mm2,满足要求!3.抗剪验算截面抗剪强度必须满足:τ = 3V/2bh n< [τ]其中最大剪力: V = 0.6×1.418×1 = 0.851 kN;方木受剪应力计算值τ = 3 ×0.851×103/(2 ×50×100) = 0.255 N/mm2;方木抗剪强度设计值[τ] = 1.4 N/mm2;方木的受剪应力计算值0.255 N/mm2小于方木的抗剪强度设计值1.4 N/mm2,满足要求!4.挠度验算计算公式如下:ν=0.677ql4/(100EI)≤[ν]=l/250均布荷载q = q1 = 0.89 kN/m;最大挠度计算值ν= 0.677×0.89×10004 /(100×9000×4166666.667)= 0.161 mm;最大允许挠度[ν]=1000/ 250=4 mm;方木的最大挠度计算值0.161 mm 小于方木的最大允许挠度 4 mm,满足要求!四、托梁材料计算托梁按照集中荷载作用下的三跨连续梁计算;托梁采用:钢管(双钢管) :Ф48×3;W=10.16 cm3;I=21.56 cm4;集中荷载P取纵向板底支撑传递力,P=1.702kN;托梁计算简图托梁计算弯矩图(kN·m)托梁计算变形图(mm)托梁计算剪力图(kN) 最大弯矩M max = 0.638 kN·m ;最大变形V max = 1.013 mm ;最大支座力Q max = 7.445 kN ;最大应力σ= 638202.086/10160 = 62.815 N/mm2;托梁的抗压强度设计值[f]=205 N/mm2;托梁的最大应力计算值62.815 N/mm2小于托梁的抗压强度设计值205 N/mm2,满足要求!托梁的最大挠度为 1.013mm 小于1000/150与10 mm,满足要求!五、模板支架立杆荷载设计值(轴力)作用于模板支架的荷载包括静荷载和活荷载。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

150m m厚板模板支撑计算书1.计算参数结构板厚150mm;层高9.65m;结构表面考虑隐蔽;模板材料为:夹板底模厚度18mm;板材弹性模量E=6000N/mm2;枋材弹性模量E=9000N/mm2;抗弯强度fm=13.00N/mm2;顺纹抗剪强度fv=1.40N/mm2;支撑采用Φ48×3.0mm钢管:横向间距1000mm;纵向间距1000mm;支撑立杆的步距h=1.50m;立杆伸出顶层水平杆中心线至支撑点的长度a=150mm;钢管直径48mm;壁厚3.0mm;截面积4.24cm2;回转半径i=1.59cm;钢材弹性模量E=206000N/mm2;抗弯强度f=205.00N/mm2;抗剪强度fv=120.00N/mm2..2.楼板底模验算1底模及支架荷载计算荷载类型标准值单位计算宽度m板厚m系数设计值①底模自重0.30kN/m2×1.0×1.2=0.36kN/m②砼自重24.00kN/m3×1.0×0.15×1.2=4.32kN/m③钢筋荷载1.10kN/m3×1.0×0.15×1.2=0.20kN/m④施工人员及施工设备荷载2.50kN/m2×1.0×1.4=3.50kN/m底模和支架承载力计算组合①+②+③+④q1=8.38kN/m底模和龙骨挠度验算计算组合①+②+③q2=4.88kN/m2楼板底模板验算第一层龙骨次楞间距L=350mm;计算跨数5跨..底模厚度18mm;板模宽度=1000mmW=bh2/6=1000×182/6=54000mm3;I=bh3/12=1000×183/12=486000mm4..1内力及挠度计算a.①+②+③+④荷载支座弯矩系数KM =-0.105;M1=KMq1L2=-0.105×8.38×3502=-107788N·mm剪力系数KV =0.606;V1=KVq1L=0.606×8.38×350=1777Nb.①+②+③荷载支座弯矩系数KM =-0.105;M2=KMq2L2=-0.105×4.88×3502=-62769N·mm跨中弯矩系数KM =0.078;M3=KMq2L2=0.078×4.88×3502=46628N·mm剪力系数KV =0.606;V2=KVq2L=0.606×4.88×350=1035N挠度系数Kυ=0.644;υ2=Kυq;2L4/100EI=0.644×4.88/1.2×3504/100×6000×486000=0.13mm c.施工人员及施工设备荷载按2.50kN按作用在边跨跨中计算计算荷载P=1.4×2.50=3.50kN;计算简图如下图所示..跨中弯矩系数KM =0.200;M4=KM×PL=0.200×3.50×1000×350=245000N·mm支座弯矩系数KM =-0.100;M5=KM×PL=-0.100×3.50×1000×350=-122500N·mm剪力系数KV =0.600;V3=KVP=0.600×3.50=2.10kN挠度系数Kυ=1.456;υ3=KυP;L3/100EI=1.456×3.50/1.4×1000×3503/100×6000×486000=0.54mm 2抗弯强度验算M1=-107788N·mm;M2+M5=-185269N·mm;M3+M4=291628N·mm比较M1、M2+M5、M3+M4;取其绝对值大的作为抗弯强度验算的弯矩..Mmax =291628N·mm=0.29kN·m;σ=Mmax/W=291628/54000=5.40N/mm2楼板底模抗弯强度σ=5.40N/mm2<fm=13.00N/mm2;满足要求.. 3抗剪强度验算V1=1777N;V2+V3=1035+2100=3135N比较V1、V2+V3;取其绝对值大的作为抗剪强度验算的剪力Vmax =3135N=3.14kN;τ=3Vmax/2bh=3×3135/2×1000×18=0.26N/mm2楼板底模抗剪强度τ=0.26N/mm2<fv=1.40N/mm2;满足要求..4挠度验算υmax=0.13+0.54=0.67mmυ=350/250=1.40mm楼板底模挠度υmax=0.67mm<υ=1.40mm;满足要求..内力图如下图..3第一层龙骨次楞验算钢管横向间距1000mm;第一层龙骨次楞间距350mm;计算跨数2跨第一层龙骨次楞采用木枋b=40mm;h=90mmW=bh2/6=40×902/6=54000mm3;I=bh3/12=40×903/12=2430000mm4.. 1抗弯强度验算弯矩系数KM =-0.125;q=q1×第一层龙骨次楞间距/计算宽度=8.38×350/1000=2.93kN/mM max =-KMqL2=--0.125×2.93×10002=--366250N·mm=--0.37kN·mσ=Mmax/W=366250/54000=6.78N/mm2第一层龙骨次楞抗弯强度σ=6.78N/mm2<fm=13.00N/mm2;满足要求.. 2抗剪强度验算剪力系数KV =0.625;Vmax=KVqL=0.625×2.93×1000=1831N=1.83kNτ=3Vmax/2bh=3×1831/2×40×90=0.76N/mm2第一层龙骨次楞抗剪强度τ=0.76N/mm2<fv=1.40N/mm2;满足要求.. 3挠度验算挠度系数Kυ=0.521;q’=q2×第一层龙骨次楞间距/计算宽度=4.88/1.2×350/1000=1.42kN/m=1.42N/mmυmax =Kυq’L4/100EI=0.521×1.42×10004/100×9000×2430000=0.34mmυ=1000/250=4.00mm第一层龙骨次楞挠度υmax =0.34mm <υ=4.00mm;满足要求..计算简图及内力图如下图..4第二层龙骨主楞验算钢管纵向间距1000mm;计算跨数5跨..第二层龙骨主楞采用双钢管A=848mm 2;W=8980mm 3;I=215600mm 41抗弯承载力验算弯矩系数K M =0.305;P=1.250×2.93×1000=3663N=3.66kNM max =K M PL=0.305×3663×1000=1117215N·mm=1.12kN·mσ=M max /W=1117215/8980=124.41N/mm 2第二层龙骨主楞抗弯强度σ=124.41N/mm 2<f=205.00N/mm 2;满足要求.. 2抗剪强度验算剪力系数K V =1.716;V max =K V P=1.716×3.66×1000=6281N=6.28kNτ=3V max /2bh=3×6281/2×2×424=11.11N/mm 2第二层龙骨主楞抗剪强度τ=11.11N/mm 2<f v =120.00N/mm 2;满足要求..3挠度验算挠度系数K υ=3.618;P ;=1.250×1.42×1000=1775N=1.78Nυmax =K υP ;L 3/100EI=3.618×1775×10003/100×206000×215600=0.72mmυ=1000/250=4.00mm第二层龙骨主楞挠度υmax =0.72mm <υ=4.00mm;满足要求..计算简图及内力图如下图..3.支撑强度验算1荷载计算每根钢管承载N QK1=11789N每根钢管承载活荷载1.0kN/m 2:N QK2=1.00×1.00×1×1000=1000N每根钢管承载荷载N QK =N QK1+N QK1=11789+1000=12789N钢管重量0.0326kN/m;立杆重量=9.50×0.0326×1000=310N水平拉杆7层;拉杆重量=7×1.00+1.00×0.0326×1000=456N扣件单位重量14.60N/个;扣件重量=7×14.60=102N支架重量N Gk =立杆重量+水平拉杆重量+扣件重量=310+456+102=868N钢管轴向力N=1.2N GK +N QK =1.2×868+12789=13831N2钢管立杆长细比验算L 0=h=1.50m=150.00cm;钢管的i=1.59cm;λ=L 0/i=150.00/1.59=94.34钢管杆件长细比94.3<150.0;满足要求..3钢管立杆稳定性验算 =0.634;P=N/A=13831/0.634×424.00=51.45N/mm 2钢管立杆稳定性51.45N/mm 2<205N/mm 2;满足要求..4.支撑支承面验算钢管脚手架立杆设配套底座150×150mm;支承面为混凝土楼板按C30考虑;楼板厚=1500mm;上部荷载为:F=13831/1000=13.83kN1支承面受冲切承载力验算βS =2.00;ft=1.43N/mm2;hO=1500-20=1480mm;η=0.4+1.2/βS=1σpc;m =0N/mm2;Um=2×150+1480+2×150+1480=6520mm;βh=10.7βh ft+0.25σpc;mηUmhO=0.7×1×1.43+0.25×0×1.00×6520×1480/1000=9659.25kN受冲切承载力9659.25kN>F=13.83kN;满足要求.. 2支承面局部受压承载力验算Ab =0.15+2×0.15×0.15×3=0.20m2;Al=0.15×0.15=0.02m2βl =Ab/Al0.5=3.16;fcc=0.85×14300=12155kN/m2;ω=0.75ωβl fccAl=0.75×3×12155×0.02=546.98kN支承面局部受压承载力546.98kN>Fa=13.83kN;满足要求..5.计算结果底模楼模板18mm;第一层龙骨次楞采用单枋b=40mm;h=90mm;间距350mm;第二层龙骨主楞采用双钢管Φ48×3.0;A=424mm2;钢管横向间距1000mm;钢管纵向间距1000mm;立杆步距1.50m..在每一步距处纵横向应各设一道水平拉杆..在最顶层步距两水平拉杆中间应加设一道水平拉杆..所有水平拉杆的端部均应与周围建筑物顶紧顶牢..无处可顶时;应在水平拉杆端部和中部沿竖向设置连续式剪刀撑..在外侧周圈应设由下至上的竖向连续剪刀撑;中间在纵横向应每隔10m左右设由下至上的竖向连续式剪刀撑;其宽度宜为4-6m;并在剪刀撑部位的顶部、扫地杆处设置水平剪刀撑..剪刀撑杆件的底端应与地面顶紧;夹角宜为45°-60°;除应符合上述规定外;还应在纵横向相邻的两竖向连续式剪刀撑之间增加之字斜撑;在有水平剪刀撑的部位;应在每个剪刀撑中间处增加一道水平剪刀撑..。

相关文档
最新文档