Beckhoff-CE 虚拟机配置向导
思科C9800-CL无线控制器 虚拟部署指南
1 介绍思科C9800-CL 无线控制器虚拟部署指南的目的是提供虚拟部署选项的概述,并提供关于C9800-CL 无线控制器初始设置的说明。
2 步骤• 配置VMware ESXi 环境 • 安装C9800-CL 无线控制器 • 初始化配置2.1配置VMware ESXi 环境2.1.1 VMware 要求 虚拟机版本VMware Virtual Machine version 11, minimum of ESXi 6.0 Update 2. C9800-CL 虚拟机要求 建议以下最小虚拟资源需求The VMware tools required to deploy the controller are as follows:• VMware vSphere Web Client. The following version is supported:-VMware vSphere Web Client 6.0•VMware vCenter Server. The following version is supported: -VMware ESXi 6.0 Update 2 (instance running vm11). This version, which meets the performance benchmarks, is fully tested and recommended.• VMware vSwitch. Standard or distributed vSwitches are supported.•Hard drive. Only a single hard disk drive is supported. Multiple hard disk drives on a VM are not supported.•vCPUs. The following vCPU configurations are supported:长流水I T- Small Template —4 vCPUs (requires minimum 4-GB RAM allocation) - Medium Template —6 vCPUs (requires minimum 16-GB RAM allocation) - Large Template —10 vCPUs (requires minimum 32-GB RAM allocation)• Virtual CPU core• Virtual hard disk space —Minimum 8 GB is required.•Virtual Network Interface Cards (vNICs).2.1.2 Creating a Network Interface on a VMIn ESXi, configure the appropriate networking needed to support C9800-CL WLC. Therecommendation is to use a trunk port for wireless management interface, use an optional access port for the Device Management interface, and use an optional access port for high-availability interface. Such as the example below:Perform the following steps in the VMware vSphere Client to create a network interface.Step 1 Log in to the VMware vSphere Client.Step 2 In the vSphere GUI, select the VM host that will deploy C9800-CL WLC. Click theConfiguration tab.Step 3 In the Networking area, click Add Networking…Step 4 Under Connection Type , retain the default settings, and click Next .Step 5 Under Network Access , select the trunk VM NIC, and Click Next.The VM NIC uplink switch port must be a “trunk ” mode port.长流水I TStep 6 Under Connection Settings , enter a name in the Network Label field. From the VLANID (Optional) drop-down list, choose ‘All (4095)’. And then click Next.Step 7 Under Summary , confirm the updates and click Finish.The newly added network interface is now available in the Networking area.vSwitch Promiscuous ModeBy default, a hypervisor vSwitch is configured to “Reject ” promiscuous mode. If C9800 is using tagged traffic (e.g. management VLAN, AP VLAN, etc.) via management port, promiscuous mode allows the vSwitch to carry tagged tr affic. Therefore configure to “Accept ” promiscuous mode for the vSwitch.长流水I TStep 1 Under hypervisor > Configuration > Networking > Networking select vSwitch# beingmapped to the C9800 management interface.Step 2 Properties> Ports > vSwitch and click Edit.长流水I TStep 3 In Security Tab > Policy Exceptions > set Promiscuous mode = Accept.2.2Installing C9800-CL in a VMware ESXi EnvironmentStep 1 Log in to the VMware vSphere Client.Step 2 From the vSphere Client menu, choose File > Deploy OVF Template.长流水I TStep 3 In the OVA wizard, select the source of the controller OVA that is to be deployed. Click Next.Step 4 In the OVA Template details field, click Next.Step 5 In the Name and Location field, specify the name for the VM and click Next.Step 6 Under Deployment Configuration , select the required profile from the drop-down list and click Next.长流水I TStep 7 Under Disk Format , select ‘Thin Provision ’ and click Next.Step 8 From the Network Mapping drop-down list, allocate one or more virtual Network Interface Cards (vNICs) to the destination network. Connect each network to a unique interface. The following mapping is recommended:• GigabitEthernet 1 to device management interface and map it to the out-of-bandmanagement network.• GigabitEthernet 2 to wireless management interface and map it to the network to reach APs and services. Usually this interface is a trunk to carry multiple VLANs. •GigabitEthernet 3 to high-availability interface and map it to a separate network for peer-to-peer communication for SSO.Note Do not connect 2 interfaces to a single subnet as that causes network loop.Click Next . And then click Next to skip the management configuration.长流水I TStep 9 Under Ready to Complete , verify all the deployment settings.长流水I TStep 10 Click Finish to deploy the OVA.The controller VM will appear on the left panel when the deployment is completed.长流水I T2.3Configuring C9800-CL initial setup from consoleStep 1 Click Power On to power on the C9800-CL WLC.Step 2 Open the C9800-CL WLC Console, it is important to click into the console window and press ANY key to access the terminal when it show "Press any key to continue."Step 3 Select “vWLC – packages.conf ”Step 4 Terminate the configuration wizard.Would you like to enter the initial configuration dialog? [yes/no]: no Would you like to terminate autoinstall? [yes]:yes长流水I T思科C9800-CL 无线控制器虚拟部署指南Page 11 of 11Step 5 Set the hostname WLC#enableWLC#configure terminalWLC(config)#hostname C9800Step 6 Add login credentials using the following command: C9800(config)#username cisco privilege 15 password Cisco123 C9800(config)#enable secret Cisco123 C9800(config)#service password-encryptionStep 7 Add an IP address on the device Management interface. C9800(config)#interface gi1 C9800(config-if)#no switchport C9800(config-if)#ip address 192.168.1.2 255.255.255.0 //Change the IP accordingly C9800(config-if)#no shut C9800(config-if)#exit Step 8 Add the route to the remote network where you want to manage the C9800-CL from. C9800(config)#ip route 0.0.0.0 0.0.0.0 192.168.1.1 //Change the gateway IP accordinglyStep 9 Configure VTYC9800(config)#line vty 0 4C9800(config-line)#login local C9800(config-line)#transport input allC9800(config-line)#exitStep 10 Login C9800-CL WLCNow you can login the C9800-CL WLC from CLI by SSH the management IP(192.168.1.2) or WEB GUI https://192.168.1.2 长流水I T。
VMware虚拟机配置教程
VMware虚拟机配置教程引言虚拟化技术的快速发展使得虚拟机成为了许多企业和个人用户的首选。
VMware作为业界领先的虚拟化平台之一,为用户提供了强大的功能与灵活性。
本文将为您介绍如何配置VMware虚拟机,以充分发挥其优势。
第一章:安装VMware虚拟机软件首先,您需要从VMware官方网站下载适用于您的操作系统的VMware虚拟机软件。
安装程序很简单,只需按照界面指引一步步操作即可完成。
安装完成后,您就可以开始创建并配置虚拟机了。
第二章:创建虚拟机在VMware软件中,点击“新建虚拟机”按钮,会弹出一个向导对话框,您需要按照提示逐步完成虚拟机的创建过程。
1. 选择虚拟机类型在第一步中,您需要选择虚拟机类型。
根据您的需求,可以选择自定义虚拟机配置或者从预配置模板创建。
如果您需要自定义配置,可以选择“自定义”选项,然后按照需要选择操作系统类型、版本和虚拟机硬件配置。
2. 指定操作系统在第二步中,您需要指定虚拟机将运行的操作系统。
如果您已经安装了操作系统ISO镜像文件,可以选择“安装操作系统时不指定”选项。
如果尚未安装,可以选择“稍后安装操作系统”选项。
3. 配置虚拟机硬件在第三步中,您可以为虚拟机配置硬件。
例如,您可以指定虚拟机的内存大小、CPU核心数、硬盘容量等。
根据您的需求,可以在这一步调整虚拟机性能与存储空间。
第三章:设置网络连接虚拟机的网络连接设置非常重要,它决定了虚拟机与外部网络的通信方式。
1. 桥接模式桥接模式将虚拟机连接到物理网络中,使其可以与其他设备直接通信。
这种模式适用于需要虚拟机与外部网络完全隔离的场景。
2. NAT模式NAT模式允许虚拟机通过主机的网络连接与外部网络通信。
这种模式适用于需要虚拟机访问外部网络但不需要其他设备直接访问虚拟机的场景。
3. 仅主机模式仅主机模式将虚拟机与主机的网络连接隔离,使虚拟机与外部网络断开。
这种模式适用于仅在虚拟机本地运行应用程序的场景。
第四章:配置共享文件夹共享文件夹功能可以方便地在虚拟机和主机之间共享文件。
虚拟机安装教程及简单配置(更新版)
VMware Workstation 是VMware 公司发行的虚拟软件,相信大家都很熟悉,它可以在一台电脑上模拟出若干个PC 而且不会影响主机的(这里的主机指的是真实的电脑)操作。
它的安装和设置比较容易但对于新手来说可能有点问题,因此我在这里用尽量比较详尽的语言和图片演示一下。
首先我区别几个名词(定义不是很准确,只是为了以后说明方便):主机:即你的电脑虚拟PC :即你在VMware 中安装的系统 虚拟机:即这个VMware 软件虚拟系统:即在VMware 中安装的系统VMware 安装目录:即VMware 这个程序的安装目录(一般为:"C:\Program Files\VMware\VMware Workstation\)虚拟PC 安装目录:即虚拟机中系统所在的目录(这个可以随意设置,比如我的是:D:\virtual PC ,可以在虚拟机的edit 菜单中的reference 选项的workspace 选项卡中设置默认的位置)虚拟机的安装:虚拟机的安装很简单这里不作说明(直接下一步、下一步可以,途中可以改一下安装目录,安装完它提示你重启,可以选no ,因为即使不重启也可以用。
不想看E 文的可以下载一下汉化补丁)===============================================================================认识虚拟机:这是虚拟机的菜单及按钮。
作用都画在图上了。
菜单基本上可以完成所有的任务。
一会介绍。
首先看看如何新建一个虚拟PC:如图 File->New->Virtual Machine...首先我们选择典型(即第一个)下一步选择操作系统及版本,我们选微软的XP下一步完成之后会成为下面的样子询问虚拟PC 的网络模式,第一个为桥接(虚拟PC 与主机处于同样的网络地位,相当于同一网段的两台电脑),第二个为NAT (网络地址翻译-主机和虚拟PC 双方不可见对方),第三个为仅能和主机通讯,第四个为不用网络。
64位虚拟机安装倍福Beckhoff
在64位的win7系统中安装虚拟机软件VMware Workstation10.0 ,在其中建立虚拟机windows XP SP3系统,然后将TwinCAT2软件安装在虚拟机系统中。
如下图
之后,按照使用倍福说明书中的方法,扫查外部组太好的EK1100,EL2008及外部模块EL2008-0022,接线图如下
要保证正确的实物接线,上电后,会有相应的指示灯亮起或亮闪,具体看资料,不再赘述。
接下来就是在打开的TwinCAT2中扫查IO模块了,右击I/O Devices 然后选择Scan Devices
然后会出现下面的错误,扫查出是Ethernet设备
我们扫查的是EtherCAT的设备,应该出现的是下面结果,扫查出的是EtherCAT设备
如何解决??
1、首先确定外部接线正确,网线插好,保证PC和设备正常连接
2、安装TwinCAT的驱动,安装好后,点showbindings,会显示两个驱动
(已经安装好的驱动)
3、在网络和共享中关闭虚拟机网络连接,
4、虚拟机中设置“桥接模式”,(桥接模式是用主机本身网卡与外界通讯)
然后就可以正常扫查了。
4.1 CE路由器上虚拟路由器的配置[共8页]
170第4章虚拟路由器组网技术4.1 CE路由器上虚拟路由器的配置还是以前几章所提到的EuroBank VPN网络为例,该网络由4个站点(San Francisco、Washington、London和Paris)组成。
每个站点只“装备”了1台CE路由器,该路由器只参与一个VPN。
有三个站点连接到位于San Jose、Washington、Paris 的PE路由器,而London站点则与Paris站点相连。
现假设EuroBank欲在其所属各部门间实施某种程度的网络隔离(比如,各站点的交易大厅网络应该与小额储蓄业务网络完全隔离,即交易部网络与零售部网络需要完全隔离。
)。
注意:就当今商业领域的兼并、分拆和收购而言,在公司的各部门或有业务往来的公司之间实施网络隔离应该是屡见不鲜。
比如,某家准备对其某项业务进行剥离的公司,就有可能会在涉及该业务的部门与其他部门之间实施网络隔离,来启动业务剥离过程。
此外,在各部门间实施网络隔离,也有可能是出于安全性考虑。
又如,一家同时生产高机密性产品和日常生活消费品的公司,肯定会对与上述两条产品线相对应的网络(业务)实施隔离,从而确保前者的高机密性。
鉴于交易(大额交易)部和零售(小额储蓄)部网络间的隔离需求,EuroBank引入了一套全新的编址方案,如表4-1所列。
由表4-1可知,EuroBank为其CE路由器的loopback接口专门引入了新的IP地址段,在前两章的示例中,根本无需考虑CE路由器的loopback接口IP地址。
表4-1 EuroBank公司新IP地址分配表4.1 CE 路由器上虚拟路由器的配置 171续表为了在公司内实现部门间网络隔离的目标,EuroBank 准备将其内联网VPN 进一步划分为两个独立的部门VPN 。
实现这一需求的方法很多,如下所列。
⏹ 在现有VPN 网络的顶层,通过访问列表来构建复杂的对等到对等VPN 。
⏹ 在每个站点都部署两台CE 路由器,各发起一条接入MPLS VPN 骨干网的链路。
在虚拟机中安装和配置操作系统的步骤(五)
在虚拟机中安装和配置操作系统的步骤虚拟机技术是一种通过软件模拟硬件环境,使一个物理计算机可以运行多个虚拟计算机的技术。
使用虚拟机技术可以实现操作系统的隔离和运行环境的快速部署。
接下来,我们将论述在虚拟机中安装和配置操作系统的步骤。
1. 确定虚拟化平台选择合适的虚拟化平台是安装和配置操作系统的第一步。
常见的虚拟化平台有VMware、VirtualBox和Hyper-V等。
根据个人需求和实际情况选择合适的虚拟化平台。
2. 下载和安装虚拟化软件下载虚拟化软件的安装包,根据指引进行安装。
在安装过程中,可以选择安装路径和其他相关配置选项。
安装完成后,启动虚拟化软件。
3. 创建虚拟机在虚拟化软件中,点击新建虚拟机的选项,进入虚拟机创建向导。
根据自己的需求填写虚拟机名称、操作系统类型、内存大小等信息。
还可以设置虚拟硬件设备,如虚拟磁盘、网络适配器等。
4. 安装操作系统将操作系统的安装光盘(ISO镜像文件)挂载到虚拟机上,然后启动虚拟机。
在虚拟机启动过程中,按照提示选择启动设备为光盘,并开始安装操作系统。
5. 配置操作系统安装完成后,进入新安装的操作系统。
根据需要进行一些必要的配置,例如设置主机名、域名、IP地址等。
还可以安装所需的驱动程序和常用软件。
6. 设置共享文件夹虚拟化软件可以提供共享文件夹的功能,可以将本机中的文件夹与虚拟机进行共享。
这样,在虚拟机中可以方便地访问和使用本机中的文件。
7. 安装增强工具虚拟化软件通常提供增强工具(Virtual Tools、Guest Additions等),安装这些工具可以优化虚拟机的性能和功能。
增强工具可以改善虚拟机与主机之间的互操作性,提供更好的图形性能等。
8. 备份虚拟机虚拟机中的操作系统和应用程序都是虚拟化的,可以方便地进行备份和恢复。
定期备份虚拟机可以保证数据的安全,并在需要时快速恢复虚拟机。
总结起来,在虚拟机中安装和配置操作系统的步骤包括选择虚拟化平台、下载和安装虚拟化软件、创建虚拟机、安装操作系统、配置操作系统、设置共享文件夹、安装增强工具和备份虚拟机等。
虚拟机VMware网络配置指南
虚拟机VMware网络配置指南工作中经常有同事的虚拟机VMware网络与工作PC不能连通,现把虚拟机网络配置的步骤整理一下,供需要的同事参考。
虚拟机VMware的网络配置主要分下面几部分内容:一、检查工作PC是否安装VMware Bridge Protocol虚拟机与PC桥接通信的必需协议,如果没有安装,请安装此协议,否则请不要进行下面的工作。
二、检查虚拟机配置了几块虚拟网卡上图表示此虚拟机配置了两块虚拟的网卡。
网卡的数量可以在创建虚拟机时增加或者删除,配置完成后也可以根据工作需要,进行增加或者删除操作。
三、检查网卡的配置信息以及MAC地址启动虚拟机后,选择“系统->管理->网络”查看网络配置信息选中其中一块网卡,查看网卡的配置信息查看网卡的IP配置信息(DHCP或者静态IP)检查网卡的MAC地址如果不正确,请手动修改与工作PC的MAC地址保持一致,设置完毕,重新启动虚拟机。
四、检查虚拟网卡的映射及网卡启动协议通过虚拟机软件VMware的菜单“Edit->Virtual Network Settings…”查看网卡的映射信息。
查看虚拟网络映射信息:网卡启动协议(DHCP或者静态IP,使用方法看图下方的文字注释)这里选择了VMnet1对应的网卡使用DHCP协议,另外的一块网卡就可以手动设置静态IP地址;如果两块虚拟网卡都选择动态IP地址,需要把VMnet8也添加到DHCP中;如果两块虚拟网卡都选择静态IP地址,则需要把上图中的VMnet1删除。
五、虚拟网卡与工作PC网卡的桥接通过虚拟机软件VMware的菜单“VM->Settings…”,建立虚拟网卡与PC网卡的桥接。
选择连接方式(用户自定义的桥接)设置完毕后,重新启动虚拟机即可。
六、网络配置文件/etc/sysconfig/network-scripts/ifcfg-eth0/etc/sysconfig/network-scripts/ifcfg-eth1。
64位虚拟机安装倍福Beckhoff
64位虚拟机安装倍福Beckhoff
在64位的win7系统中安装虚拟机软件VMware Workstation10.0 ,在其中建立虚拟机windows XP SP3系统,然后将TwinCAT2软件安装在虚拟机系统中。
如下图
之后,按照使用倍福说明书中的方法,扫查外部组太好的EK1100,EL2008及外部模块EL2008-0022,接线图如下
要保证正确的实物接线,上电后,会有相应的指示灯亮起或亮闪,具体看资料,不再赘述。
接下来就是在打开的TwinCAT2中扫查IO模块了,右击I/O Devices 然后选择Scan Devices
然后会出现下面的错误,扫查出是Ethernet设备
我们扫查的是EtherCAT的设备,应该出现的是下面结果,扫查出的是EtherCAT设备
如何解决??
1、首先确定外部接线正确,网线插好,保证PC和设备正常连接
2、安装TwinCAT的驱动,安装好后,点showbindings,会显示两个驱动
(已经安装好的驱动)
3、在网络和共享中关闭虚拟机网络连接,
4、虚拟机中设置“桥接模式”,(桥接模式是用主机本身网卡与外界通讯)
然后就可以正常扫查了。
虚拟机的静态网卡配置和工具的连接分析
虚拟机的静态网卡配置和工具的连接
提醒:必须使用NAT模式,桥接模式只能在有外网的时候才分配网关。
而NAT模式有固定网关
第一步:先查看网关:
第二步:
进入虚拟机+ifconfig,查看dhcp 的ip:
第三步:进入网卡配置文件:/etc/sysconfig/network-scripts/ifcfg-eth0:
添加ip,网关等。
即IPADDR:上面ifconfig出来的IP地址就行
NETMASK=255.255.255.0
GATEWAY=填写网络编辑起里面的
DNS1同上:
配置好后重启network服务:
第四步:修改/etc/hosts:添加映射
第五步:修改本机
C:\Windows\System32\drivers\etc 中的hosts文件:添加网络映射
测试一下,主机和虚拟机之前ping主机名能否ping通:
OK!!!!
下面使用xshell远程连接虚拟机:
用户名和密码就是你要登录的虚拟机的用户和密码:
完成,完美!!!
下面连接notepad++
和上面xshell是一样的:。
BECKHOFF 产品简明操作指南_彩色
注意
说明或提示! 该标志表示这些信息能够帮助您更好地理解安全说明。
警告
对人身、环境或设备有危险! 不遵守本标志相关的安全说明可能危害个人、环境或设备安全。
危险
有严重人身伤害危险 ! 不遵守本标志相关的安全说明将直接危及个人生命和健康安全。
1
BECKHOFF 简明操作指南
目录
1. 安装与拆卸 ......................................................................................................... 7
1.3 BC、BX 系列总线控制器的安装及拆卸 ..........................................................................12 1.4 12 mm 标准模块的安装及拆卸.........................................................................................12 1.5 EL6xxx 系列通讯模块的安装与拆卸.................................................................................13 1.6 光纤模块接头安装 .............................................................................................................14 1.7 导轨安装..............................................................................................................................15
BECKHOFF CX1020控制器FTP操作说明
FTP操作说明一、PLC主机CE系统设置:1、将PC机与PLC主机通过一根网线连接在一起(中间有交换机也可以),将PC机的IP地址设成与PLC主机的IP地址前三位相同;2、双击运行PC机上的,打开的界面如图1.1所示:图1.1 图1.2 图1.33、点击file->Connect如图1.2所示,在弹出的connect界面中输入该PLC主机的IP地址如图1.3,再点击OK即进入PLC的CE系统界面。
4、进入控制面板界面,如图1.4所示,点击CX Configuration。
图1.45、选择FTP标签,将选择项中Allow anonymous Vroots的勾去掉,其他都打上勾,设置文件读取路径,双击底下空白处,选择Add user,如图1.5所示。
图1.56、设置用户名和密码,如图1.6所示,点击OK。
图1.67、双击对应的用户名,选择Enable user,确认右边的Enabled项中有一个X,点击Apply,再点击OK完成设置,如图1.7所示。
图1.78、设置完成后重新启动CE系统。
注:CE系统的设置并非一定要通过PC机相连进行设置,最简单的方法就只在触摸屏上直接进行CE系统的设置,上述步骤4到7。
二、通过FTP进行远程文件的读取1、将PC机与PLC主机通过一根网线连接在一起(中间有交换机也可以),将PC机的IP地址设成与PLC主机的IP地址前三位相同;2、打开PC机的资源管理器或者我的电脑,在地址栏中输入ftp://以及PLC主机相应IP地址并回车确认,如图2.1所示;图2.13、打开界面如图2.2所示,这就可以进行文件的读取了。
图2.2附:PLC监控软件客户端自动关闭的解决方法在实际应用中可能会遇到PLC监控软件客户端自动关闭的情况,这样的话我们在远程就无法实现对PLC的监控了,碰到这种情况时,我们可以通过远程的方法对其进行启动,当然前提条件是我们已经对PLC主机进行过设置,也就是上述第一部分已经完成,具体步骤如下:1、连接好PC机,并且修改好IP地址;2、点击开始->运行;3、输入telnet:\\以及相应的PLC主机的IP地址,点击确定;4、在login:后面输入先前设置的用户名(guest)并回车确定,在password:后面输入先前设置的密码(1,实际操作时不会显示密码)回车确定;5、接着输入windows\cerdisp ,然后回车确定并关闭窗口,这样PLC监控软件客户端又将重新开启。
BeckhoffCE虚拟机配置向导
BeckhoffCE虚拟机配置向导BeckhoffCE虚拟机配置向导概述通常我们需要在笔记本上对PLC程序进行预调试,有些笔记本电脑在把TwinCAT切换到RUN模式时会导致蓝屏死机;或者笔记本电脑是WIN764位系统,本机TwinCAT2无法切换到RUN模式。
使用虚拟机可以很好的避免这些问题。
文档中包含的文件备注关键字:WindowsVirtualPC、beckhoffCETwinCAT免责声明我们已对本文档描述的内容做测试。
但是差错在所难免,无法保证绝对正确并完全满足您的使用需求。
本文档的内容可能随时更新,也欢迎您提出改进建议。
文档内容可能随时更新如有改动,恕不事先通知一.虚拟机配置向导首先安装WindowsVirtualPC,并根据系统提示重启。
\培训光盘\软件安装\如何安装CE虚拟机示例\Windows6.1-KB958559-x86-RefreshPkg.msu解压Beckhoff_VPC_WEC7_HPS_v500l_TC211R3_B2234.zip到文件夹中。
/Software/embPC-Control/CE/Solutions/VirtualPC/打开WindowsVirtualPC在左侧菜单内找到解压出来的文件夹,打开双击打开CE7的虚拟机文件成功进入CE7虚拟机界面:二.添加虚拟网卡笔记本侧:开始---运行---输入hdwwiz.exe命令,进行打开运行添加硬件的菜单操作选择“手动”添加在添加硬件类型中选择“网络适配器”选择“M icrosoft”中的“MicrosoftLoopbackAdapter”安装成功后出现:并且在笔记本的网络连接里面可以看到虚拟网卡:修改IP地址,修改方法同有线网卡,例如固定IP地址:192.168.1.123三.笔记本与虚拟机链接初次使用需要开启虚拟机网卡:登入CE7虚拟机,选择“工具”——“设置”选择“网络”,网络适配器数量为0,发现找不到网卡在不关闭“设置”菜单的情况下,选择“操作”——“关闭”——“关闭虚拟机”将“网络适配器的数量”选择为1,并且将新增的适配器选为之前新建的虚拟网卡,让后点击确定重新打开CE7虚拟机,发现可以在虚拟机的控制面板中找到网卡将其设置为固定IP地址,例如:192.168.1.1选择OK,并且重启,发现虚拟机右下角出现连接标志:使用笔记本侧的SystemManager进行连接测试,可以成功添加路由通过切换目标控制器状态,可以进一步检测是否成功连接CE7虚拟机。
倍福模块配置方式
.倍福模块配置技术文档一:准备工作1;首先准备好倍福模块所需的配置文件,如下图:位的计算机,或Windows7 322;准备一台带有Windows XP 192.168.2.3 改为并将IP二:安装配置盘或其他盘创建一个文件夹,命名为;首先在电脑的C1复制到该文件夹中并tcat_2110_2241IOPLC。
再将应用程序。
安装过程中的语言选择英语即可,如双击安装,如图1-11-3 1-2图。
安装成功后重启电脑,如图..1-11-2 ..1-3中并IOPLCIOPLC2;将配置文件中的文件复制到文件夹。
根据车型,将电机数量改为相应2-1双击点开程序,如图IOPLC。
展开并重置配置,如图2-3Project。
如图数量,2-2点击2-4文件夹中便会自动生成相应文件,如图2-1..2-22-3 ..2-4打开配System Manager打开电脑右下角倍福程序,点击3;3-1.置程序,如图3-1选择项中点现在正式进入配置阶段,首先在Options选择与模3-3的对话框,会出现如图3-2击网卡选择,如图。
块通讯的网卡点击install安装即可。
..3-23-3 ..网卡设置完毕后,紧接着扫描模块,如图3-4。
之后便会确认网卡,如图3-5,点击确认即可3-43-5.IO装置中便会出现Box 1(BK1120)如图3-6。
扩展开便会出现扫描过后的模块类别及数量,如图3-73-63-7.4;添加PLC项目,获取模块详细数据,如图4-1,4-2。
之后便会有需要配置的模块类别,包括开关量输入输出,模拟量输入输出,电机驱动等等,如图4-34-14-2..4-3。
如图5-15;首先打开开关量输入,选中第一个模块双击,配置页。
,并勾选All Types便会弹出一个配置页面,如图5-2+ShiftKL1408模块,单击模块输入第一通道面左侧便会出现再点击Continuous,键再点击该模块的最后一个通道,并勾选5-3这样就完成了一个开关量输入的模块的配置,如图确认,5-1 ..5-25-3..配置完成后对应模块便会出现一个右上扬的箭头,如图5-45-4将开关量输入配置完成后,紧接着配置开关量输出,扩展出开关量输出模块,并双击第一个模块,如图5-5。
CE路由器基本操作及配置
远程线程管理设置 设置登录密码 启动登陆进程 退出全局设置 保存当前配置
返回目录
CE路由器基本配置 路由器基本配置
四、cisco路由器基本配置命令实例 路由器基本配置命令实例
Router> enable Router#configure t Enter configuration commands, one per line. End with CNTL/Z. Router(config)#hostname R1 R1(config)# R1(config)#enable password cisco R1(config)#line vty 0 4 R1(config-line)#password cisco R1(config-line)#login R1(config-line)#exit R1(config)#inter s0/0/0 或则 interface F0/0 R1(config-if)#ip address 192.168.1.2 255.255.255.252 R1(config-if)#no shut R1(config-if)#exit R1(config)# ip route 0.0.0.0 0.0.0.0 192.168.1.1 R1(config)#end R1#wr
返回目录
CE路由器基本配置 路由器基本配置
2、Cisco路由器中扩展 、 路由器中扩展Ping测试方法如下: 测试方法如下: 路由器中扩展 测试方法如下 R1>enable R1# R1#ping ip Target IP address: 192.168.1.1 ------要测试的目的IP Repeat count [5]: 100 ------Ping包次数 Datagram size [100]: 64 ------Ping包大小 Timeout in seconds [2]: Extended commands [n]: Sweep range of sizes [n]: Type escape sequence to abort. Sending 100, 64-byte ICMP Echos to 192.168.1.1, timeout is 2 seconds: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Success rate is 100 percent (100/100), round-trip min/avg/max = 1/1/4 ms R1#
思科虚拟无线局域网控制器 8.2 配置向导和最佳实践说明书
思科虚拟无线局域网控制器 8.2 配置向导和最佳实践 v1最后更新日期:2015 年 11 月 23 日关于本解决方案虚拟无线控制器 (vWLC) 能够以具成本效益的方式管理、保护和优化本地和分支机构无线网络的性能。
虚拟无线控制器有助于服务器整合,并通过减少中断提高业务连续性,是中小型企业的理想之选。
作为思科统一无线网络的组件之一,虚拟无线控制器能够实现 Cisco Aironet 接入点、Cisco Prime 基础设施和思科移动业务引擎之间的实时集中通信。
这款虚拟无线控制器专为具有虚拟化意向的组织而设计,而且能够为中小型企业部署提供以下优势:•为最多 200 个分支机构提供集中式无线网络可视性和可控性功能•IT 管理人员能够通过 FlexConnect 对最多 200 个接入点和 3000 个客户端进行配置、管理和故障排除•实现安全访客接入、符合支付卡行业 (PCI) 法规的非法检测,以及本地交换 Wi-Fi 音频和视频•与分支机构网络的 Cisco FlexConnect 解决方案实现可靠连接•防止连接至远程控制器的接入点因分支机构 WAN 故障而受到影响更多 vWLC 资源信息位于/c/en/us/products/wireless/virtual-wireless-controller/index.html关于本演示本演示展示如何使用运行 8.2.1.97 软件的 vWLC 所提供的基于 HTTP 的配置向导。
通过配置向导可配置控制器上的基本设置。
从工厂收到控制器后或已将控制器重置到出厂默认设置后,可运行该向导。
注意:本演示中使用的当前代码为 Beta 版,而且不支持某些 AP 型号。
在本演示中,不建议用户将 AP 连接到控制器上。
本预配置演示包括以下内容:•场景 1:vWLC 配置向导•场景 2:最佳实践要求下表概括该预配置演示要求。
表 1.演示要求监控工作站•笔记本电脑终端套件首选终端路由器•已为 dCloud 注册并配置的 819W 路由器受支持终端路由器/AP•已为 dCloud 注册并配置的路由器•Cisco Aironet 系列接入点(3000、2000、1000 系列)用户设备•平板电脑/智能手机/笔记本电脑拓扑此内容包含预配置的用户和组件,旨在说明解决方案脚本场景和功能。
内容分析虚拟设备初始配置指南(CA版本2.3)说明书
Content Analysis Virtual Appliance Initial Configuration GuideCA Version2.3Table of ContentsLegal Notice2 Introduction to Content Analysis4 Terminology7 Access Symantec Documentation8 Contact Us8 Verify VMware Requirements8 Prepare for Initial Configuration9 Retrieve Your Serial Number9 Set Up Content Analysis10 Download and Extract the VAP File11 Create the Virtual Appliance12 Power On the Virtual Appliance12 Enter Your Serial Number13 Configure the Virtual Appliance14 Access the Web Management Console16 Install the VA Appliance Certificate and License16 Configure Explicit Proxy18 Log onto the CLI19 Prevent Licensing Issues20Introduction to Content AnalysisSymantec Content Analysis is a next-generation antivirus,malware,and spyware detection system.Content Analysis2.3 includes the following features:l Malware and Antivirus Scanning—Content Analysis supports Symantec,Kaspersky,McAfee,and Sophos antivirus engines and virus signature databases.You can use one or two AV engines with Content Analysis.l Predictive Analysis—Optional subscription services from Symantec and Cylance use an advanced artificial intelligence engine to identify malware.l File Reputation Service—Content Analysis generates SHA1,MD5,and SHA-256hashes for each file it processes.These hashes are compared with Symantec's cloud-based File Reputation classification service to identify known files.The service uses reputation scores,numbers(1-10)that indicate whether files are known to be trusted or malicious;low scores are less likely to be threats whereas high scores are more likely.Depending on the reputation score,files are then either blocked if the score is high,passed to the user as safe if the score is low,or processing continues with anti-virus scanning and sandboxing if the service doesn't know whether the file ismalicious.l Manual File Blacklist and Whitelist—As your organization identifies files that are known good or bad,you can add them to a list of manually defined file hashes to either allow or deny those files without further processing.l Sandbox Integration with external vendors(Symantec Malware Analysis,Lastline,or FireEye)—Sandbox services use different methods to identify the actions an executable file would take on a client workstation,including malicious URL web requests and changes to system files.l Endpoint Integration—As the sandbox detects malware,Content Analysis can query a CounterTack Sentinel server in your network to determine which users(if any)have retrieved it.If Symantec Endpoint ProtectionManager(SEPM)is integrated with Content Analysis,the administrator is notified when the sandbox finds amalicious file and provides an option to add the file hash to a blacklist on the SEPM.l Cached Responses—When a Content Analysis module determines a verdict(clean vs.malicious)for a file,it will cache the file hashes and verdicts to avoid having to scan the same file on subsequent requests.Content Analysis has separate caches for responses from each of its services:antivirus,file reputation,predictive analysis,and sandboxing(threats and clean).l Symantec Global Intelligence Network(GIN)—Users are protected by the Symantec WebFilter and GIN databases on the ProxySG appliance,and when malware is discovered through scanning,those results can be shared with WebFilter to classify bad URLs for the benefit of all GIN users worldwide.Symantec Content Analysis2.31.A user in the protected network requests a file from the Internet.2.The ProxySG appliance evaluates policy for the user's request,and allows or denies the request according topolicy.3.The ProxySG appliance compares the file against the Symantec WebFilter and GIN databases.If the domainhosting the file has been categorized as a malware source,the file download is denied and the user is notified.If the domain is not recognized,the file is sent to Content Analysis for inspection.4.Content Analysis looks for the file hash in each of its caches(Antivirus,File Reputation service,PredictiveAnalysis,and Sandboxing).If the hash is located in a cache,Content Analysis either serves or blocks the filebased on the verdict.5.Content Analysis compares the file details against the both the manual blacklist/whitelist and the Symantec FileReputation service.If the file's hash is on the blacklist or results in a malicious reputation score,the file is blocked.If the file's hash is on the whitelist or results in a reputation score that is trusted,scanning is suspended and the file is sent to the user.If the file's reputation score is unknown or the hash is not on the whitelist or blacklist,the file is compared against the virus scan cache.If not present,the file is forwarded to the enabled antivirus scanners.6.The file is examined by optional predictive analysis services(Symantec Advanced Machine Learning and/orCylance),and then scanned by the configured antivirus engines for known virus signatures.If the file containsmalware,the file is blocked and the user receives a deny page with a description of the virus or malware.7.If the file is clean,but is of a suspicious type(such as an executable or a type defined in the sandboxingconfiguration),it is simultaneously sent to the user and forwarded to an external sandbox appliance/service forfurther analysis.(Note: If you prefer real-time sandboxing for a particular file type,you can select the Wait forResult option when configuring general sandbox settings.)The results of the sandbox analysis are reported to theVirtual Appliance Initial Configuration Guide administrator and shared with Symantec GIN.If the file is malicious,the Content Analysis administrator is notified via email or other configured notification method.8.If the sandbox analysis found the file to be malicious,Content Analysis queries the CounterTack Sentinel server(ifconfigured)to determine if any workstations in the network have been infected.That information is then included in the report emailed to the administrator.If Symantec Endpoint Protection Manager(SEPM)is configured,Content Analysis notifies the administrator,providing the option to add the file hash to a blacklist on the SEPM.Recommended ReadingBefore you set up your set up your Content Analysis Virtual Appliance for the first time,Symantec recommends that you review the following documentation:l VMware Documentation,for assistance with setting up your virtualization environment:/support/pubs/l Symantec Product Documentation,for Content Analysis:https:///en_US/Documentation.htmll Symantec Content Analysis Release Notes,which contains information on third-party requirements,known issues,and other important information for setting up Content Analysis whether as part of an on-box solution or asa virtual appliance.Release notes are available when downloading an image.Symantec Content Analysis2.3TerminologyImportant terms used in Symantec documentation are listed alphabetically in the following table.In some cases,this document uses abbreviations instead of expanded forms.While using this document,refer to this table to determine the meaning or expanded form of a term.Virtual Appliance Initial Configuration GuideAccess Symantec DocumentationAccess Content Analysis release notes,Content Analysis WebGuide,and other documentation on the Symantec Support site.1.Go to the Symantec Support site:https://2.Click Documentation.3.Search for Content Analysis Software-CA.Documentation for all versions is listed4.To narrow down the search,you can select a version from the drop-down list.Release notes are available when downloading the image.1.On the Symantec Support site,select Downloads>Network Protection(Blue Coat)Downloads.2.When prompted,log in with your MySymantec credentials.3.Select Content Analysis and choose a product line and model.4.Select the software version for the release notes you want to view.5.Locate the PDF and download the file.Contact UsWe appreciate your comments about this guide.Please comment on specific errors or omissions,accuracy,organization, subject matter,or completeness of this book.To send feedback on this or other Symantec product documentation,write to us at documentation_******************.Verify VMware RequirementsIf you are running Content Analysis as a virtual appliance,follow these guidelines to achieve satisfactory performance and operation.Symantec recommends that the virtualization environment has the following resources:l VMware®ESX Server5.5or6.0l4CPU Coresl16GB RAMl100GB hard disk spacel3Virtual Network InterfacesYour VMware license must be Enterprise or Enterprise Plus if you want to use remote serial connections.For more information,please refer to VMware support.Symantec Content Analysis2.3Prepare for Initial ConfigurationThe initial configuration wizard prompts you to configure basic network settings.Record the information specific to your deployment in this table,and then use your notes for reference when you go through the installation process.Print out this table for reference.Retrieve Your Serial NumberYou must use the correct serial number to ensure that your license is valid.To retrieve appliance serial numbers:1.Make sure you have a MySymantec username and password.In addition to retrieving appliance serial numbers,these credentials are required for obtaining your license anddownloading software upgrades.If you do not have a MySymantec account,you can create one athttps://.2.Locate the e-mail you received from Symantec following your purchase of Content Analysis Virtual Appliance.This e-mail contains the software activation codes as well as a link to the Symantec Network Protection Licensing Portal.Virtual Appliance Initial Configuration Guide3.Log in to the Symantec Network Protection Licensing Portal(NPLP):a.Click the link embedded in the e-mail(https:///eservice_enu/licensing/register.cgi).The web browser displays the NPLP page.b.Click Sign in.c.On the login screen,enter your MySymantec username and password,and then click Login.The NPLP displays the Home page.4.In the Enter Activation Code field,enter the activation code from your e-mail.5.Click Next.The License Agreement page opens.6.Read and accept the License Agreement,and then click Next.The serial numbers page opens.7.Record the appliance serial number.You will need this number to complete the initial configuration wizard.Each serial number is unique.When performing initial configuration,ensure that you use a dedicated serial number.Reusing a serial number from another Virtual Appliance will result in the license to be suspended for both Content Analysis VA installations.Set Up Content AnalysisIf you are using Content Analysis for the first time,perform the following steps to install and set up Content Analysis.1.Download the VAP file from the Symantec Support site.See"Download and Extract the VAP File"on page 11.2.Import the OVF file to your VMware client to create the Content Analysis VA.See"Create the Virtual Appliance"on page 12.3.Enter the valid serial number to activate Content Analysis.See"Enter Your Serial Number"on page 13.plete the steps in the initial configuration wizard to configure the Content Analysis VA.See"Configure the Virtual Appliance"on page 14.5.Install the Content Analysis license.See"Install the VA Appliance Certificate and License"on page 16.6.(Optional).Configure a proxy for Internet access.If your Content Analysis deployment requires that all traffic is processed by a ProxySG appliance,see"Configure Explicit Proxy"on page 18.Download and Extract the VAP FileLog in to the Symantec Support site and download the Content Analysis Virtual Appliance Package(VAP)file.The VAP is a.zip file that contains:l An Open Virtualized Format(OVF)filel Two Virtual Machine Disk Format(VMDK)files:o CASMA-VA-disk1.vmdk(for the boot disk)o CASMA-VA-disk2.vmdk(for the virtual disk)1.Go to https://.2.Select Downloads>Network Protection(Blue Coat)Downloads.3.When prompted,log in with your MySymantec credentials.4.From the Product List,select Content Analysis.5.Select the CAS-VA product line.6.Select the software version from the Product Versions or Archived Versions tab.7.Select the zip file and release notes and click Download Selected Files.The first time you download files,you will be prompted to install the Download Manager.Follow theonscreen prompts to download and run the installer.8.The Download Manager window opens.Select the download location.9.Extract the contents of the VAP file to a location that you can access from the system where you are running theVMware client.The OVF file includes a pointer to the.vmdk files;thus,you must extract and store the contents of the.zip filewithin the same folder.Do not rename the files.Create the Virtual ApplianceAfter you extract the OVF file,create the virtual appliance by deploying the OVF template.1.Log into VMware client.2.Select File> Deploy OVF Template.The VMware client displays a wizard.3.In the Source dialog,click Browse and browse to where you extracted the OVF file.4.Click Next.5.Verify the details for OVF template and click Next.6.Specify a name for the VA and the inventory location,and then click Next.7.Select where to put the VA(host or cluster)and click Next.8.Select where to store the virtual machine's files and click Next.9.Specify thick or thin provisioning for the disk format and click Next.If you select thin provisioning,VMware allocates only the required amount of virtual disk space for the VA.Thick provisioning could result in slightly better performance,but it is not required.Refer to VMware documentation if you require more information on virtual disk provisioning.10.Select a network to map to and click Next.11.On the Ready to Complete dialog,review your settings.12.(Optional)At the bottom of the dialog,select Power on after deployment to power on the VA after deployment.Ifyou do not select it,you can power on the VA later.13.Click Finish.The VMware client displays a"Deploying<name>"message with a progress bar.When deployment is complete,close the message.The inventory on the left displays the VA.Power On the Virtual ApplianceIf you did not power on the VA in step12of the previous procedure,power it on now.1.Right-click the Content Analysis VA in your inventor and select Power> Power On.2.Verify that the VA is powered on.If it is powered on,its icon should look similar to the following:If the VA is already powered on,the Power>Power On option should be unavailable.Enter Your Serial NumberThe first time you open the VM's Console window,you will be prompted to enter the serial number of your Content Analysis Virtual Appliance;this process activates your Virtual Appliance.After your serial number is validated,you can set up the Content Analysis VA with the initial configuration wizard.1.Locate the serial number that you retrieved earlier(see"Retrieve Your Serial Number"on page 9).2.In the VMware client,click the Content Analysis VA(located in the inventory on the left).3.Click the Console tab.The VMware client opens the Console window,where you are prompted to enter the serial number.4.Type your serial number and press Enter.5.If you receive an error message indicating that the serial number is not valid,check the number and try again.If the serial number is not accepted,stop and contact Symantec Support.When the system has determined the serial number is valid,the console will prompt you to press Enter three times.6.Press Enter three times.The console displays a menu similar to the following.Copyright(c)2017,SymantecWelcome to the Content Analysis CLIVersion: 2.2.1.1Release id:154010--------------------MENU--------------------1)Command Line Interface2)Setup--------------------------------------------Enter option:Configure the Virtual ApplianceFollow the prompts to complete initial configuration of Content Analysis.When you are typing in the Console window,the mouse is inactive and the cursor is restricted to the Console.To release the cursor from the Console and use the mouse elsewhere,press Ctrl+Alt.To return to typing in theConsole,click the mouse anywhere in the Console window.1.From the menu,select2to run the Setup console and start the initial configuration wizard.When prompted,hit any key to begin;the first page of the wizard opens.2.Select the number corresponding to the interface you want to configure;1(0:0,the management interface)is thedefault choice.3.Referring to your notes in Prepare for Initial Configuration,enter the following details when prompted:l IP address(you will use this IP address for the web console)l Subnet maskl IP address for the default gatewayl IP address for the primary DNS server4.The wizard presents you with a summary of the interface settings and gives you an opportunity to change them.When the settings are correct,enter N at the Would you like to change any of them?prompt.5.Create a console password for the admin user.It is recommended that the password be a combination ofalphanumeric characters,at least8characters long.The console does not display the characters as you type them,nor are asterisk placeholders displayed.Symantec Content Analysis2.36.Verify the console password by typing it again.7.Enter an enable password;this password is required when using privileged mode in the command-line interface.8.Verify the enable password by retyping it.The Configuration Complete message displays in the console.Virtual Appliance Initial Configuration GuideAccess the Web Management ConsoleVerify that you can access the web management console.Refer to the Release Notes for a list of supported browsers.1.Open a web browser.2.In the address bar,enter the URL:https://<IP_address>:8082(where<IP_address>is the IP address you specified in the initial configuration wizard)The web browser displays the Content Analysis login prompt.3.Enter admin for the username,and enter the console password you configured during initial configuration.4.When you initially log in to the web management console,you will be prompted to configure an appliance certificatefor the VA.See"Install the VA Appliance Certificate and License"below.Install the VA Appliance Certificate and LicenseThe first time you log into the web management console,you are prompted to configure the virtual appliance certificate, which contains the virtual appliance base license.To install the appliance certificate,Content Analysis must be configured with the correct DNS server.Thedownload will fail if Content Analysis cannot access the Internet or the DNS server.1.Configure the appliance certificate:a.In the Invalid or Missing Birth Certificate dialog shown above,enter your Blue Coat/MySymanteccredentials.b.Click Configure Birth Certificate.The appliance certificate and base license are downloaded from Symantec and installed on the virtualappliance.Symantec Content Analysis2.3If the configuration failed,make sure you have the correct DNS server configured on ContentAnalysis.To verify DNS settings,select Settings>Network,and make sure you can ping the DNSserver from Content Analysis(Utilities>Ping).2.Confirm that the license is active:a.Select System>Licensing.b.Verify that the base license has a check mark in the Active column.Configure Explicit ProxyIf the secure environment your Content Analysis virtual appliance is deployed in requires that all traffic destined for the Internet traverses a ProxySG appliance,you can configure the proxy settings in the Content Analysis management console.1.Log in to the web console.2.Browse to Settings>Proxy.3.Click Save Changes.4.Refresh the browser window.Log onto the CLILog onto the CLI through an SSH connection or through the Content Analysis VMware console.Log on using SSH1.Open an SSH client(such as PuTTy)and specify the following information for a new host connection:l Host Name(or IP address)—The IP address that you specified for the Virtual Appliancel Port—222.Click Open.3.The SSH window opens with a note about the private key.4.Click Yes to accept the private key and dismiss the private key message.Future SSH connections to this virtual appliance will be compared against this key,and an alert will be presented if it does not match with the key saved during this initial session.5.At the login as:prompt,type admin and press Enter.6.At the password:prompt,enter your password and press Enter.The CLI prompt is displayed:CAS>.7.To enter privileged mode,type enable,and enter the enable password when prompted.Log on through the VMware ConsoleThe VMware Console emulates an out-of-band console connection in that can be accessed regardless of theconfigured IP address for the VM.1.In the VMware client,locate the Content Analysis VM in the inventory.2.Click the Console tab,or right-click the Content Analysis Virtual Appliance,and select Open Console.The console prompts you to press Enter three times.3.Press Enter three times.A menu displays in the Console window.4.Enter1to use the Command Line Interface.The CLI prompt is displayed:CAS>.5.To enter privileged mode,type enable,and enter the enable password when prompted.Prevent Licensing IssuesTo prevent licensing issues,ensure that the VA is allowed network access to the license validation server athttps://.If communication with the server fails,a network issue may be present.A constant internet connection is required for Content Analysis to communicate regularly with the license validation server to confirm that the serial number is valid. Duplicate Serial NumbersIf the license validation server detects duplicate serial numbers,your license is invalidated.Verify your license in the Network Protection Licensing Portal and contact Symantec Customer Support if you have problems with your license or serial numbers.。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
BeckhoffCE虚拟机配置向导
概述
通常我们需要在笔记本上对PLC程序进行预调试,有些笔记本电脑在把TwinCAT切换到RUN模式时会导致蓝屏死机;或者笔记本电脑是WIN764位系统,本机TwinCAT2无法切换到RUN模式。
使用虚拟机可以很好的避免这些问题。
文档中包含的文件
备注
关键字:WindowsVirtualPC、beckhoffCETwinCAT
免责声明
我们已对本文档描述的内容做测试。
但是差错在所难免,无法保证绝对正确并完全满足您的使用需求。
本文档的内容可能随时更新,也欢迎您提出改进建议。
文档内容可能随时更新
如有改动,恕不事先通知
一.虚拟机配置向导
首先安装WindowsVirtualPC,并根据系统提示重启。
\培训光盘\软件安装\如何安装CE虚拟机示例\解压到文件夹中。
打开WindowsVirtualPC
在左侧菜单内找到解压出来的文件夹,打开
双击打开CE7的虚拟机文件
成功进入CE7虚拟机界面:
二.添加虚拟网卡
笔记本侧:开始---运行---输入命令,进行打开运行添加硬件的菜单操作
选择“手动”添加
在添加硬件类型中选择“网络适配器”
选择“M icrosoft”中的“MicrosoftLoopbackAdapter”
安装成功后出现:
并且在笔记本的网络连接里面可以看到虚拟网卡:
修改IP地址,修改方法同有线网卡,例如固定IP地址:
三.笔记本与虚拟机链接
初次使用需要开启虚拟机网卡:
登入CE7虚拟机,选择“工具”——“设置”
选择“网络”,网络适配器数量为0,发现找不到网卡
在不关闭“设置”菜单的情况下,选择“操作”——“关闭”——“关闭虚拟机”
将“网络适配器的数量”选择为1,并且将新增的适配器选为之前新建的虚拟网卡,让后点击确定
重新打开CE7虚拟机,发现可以在虚拟机的控制面板中找到网卡
将其设置为固定IP地址,例如:
选择OK,并且重启,发现虚拟机右下角出现连接标志:
使用笔记本侧的SystemManager进行连接测试,可以成功添加路由
通过切换目标控制器状态,可以进一步检测是否成功连接CE7虚拟机。