685使用说明书

合集下载

VD685使用说明手册

VD685使用说明手册

VD685 使用说明手册尊敬的用户:非常感谢您选择使用本手机。

使用前请认真阅读本说明书. 本公司拥有对本手册的最终解释权,如手册中所述内容与您的手机不符,请以您的手机为准。

本公司保留修改技术规则而不事先通知的权利。

本公司保留修改本说明书的权利,恕不另行通知。

制造商保留在未事先通知的情况下对技术产品规格进行修改的权利。

安全须知1.请勿让儿童操作手机2.请勿在加油站、煤气站等易燃易爆的地方使用手机3.请勿随意丢弃废电池4.请到指定的专业维修点维修,切勿私自拆装手机目录1基本知识................................................................. 错误!未定义书签。

1.1 简介......................................................... 错误!未定义书签。

1.2 安全须知................................................. 错误!未定义书签。

1.3 安全警告和注意事项............................. 错误!未定义书签。

2使用前..................................................................... 错误!未定义书签。

2.1 各部分的名称和说明............................. 错误!未定义书签。

2.1.1技术参数............................................................................... 错误!未定义书签。

2.1.2按键说明............................................................................... 错误!未定义书签。

BenQ TH685 数码投影机用户手册说明书

BenQ TH685 数码投影机用户手册说明书

保修及版权信息有限保修在正常使用和存放情况下,BenQ 对本产品的任何材料和工艺缺陷提供保修。

要求保修时必须提供有效三包卡和有效发票。

如果在保修期内发现本产品有缺陷,BenQ 唯一的义务和针对您的独家补救办法是更换任何有缺陷的部件(包括劳务费)。

当您购买的产品有任何缺陷时应立即通知经销商,以获得保修服务。

重要事项:如果客户未按照 BenQ 的书面用法说明使用本产品,将不适用上述保修。

尤其是环境湿度必须介于 10% 和 90% 之间、温度介于 0°C 和 35°C 之间、海拔高度低于 4920 英尺,以及避免在多灰尘的环境下操作本投影机。

本保修授予您特定的法律权利,您可能还享有其它权利,具体取决于您所在的国家。

有关其它信息,请访问。

版权明基智能科技(上海)有限公司 (BenQ) 版权 © 2021。

保留所有权利。

未经明基智能科技(上海)有限公司事先书面许可,不得以任何形式或方式,包括电子、机械、磁性、光学、化学、手写或其它方式,对本文的任何部分进行复制、传输、转译、储存于检索系统或翻译成任何文字或电脑语言。

免责声明对于本文之任何明示或默示内容,明基智能科技(上海)有限公司不做任何保证,亦拒绝对任何特殊目的之商用性或适用性目的予以保证。

此外,明基智能科技(上海)有限公司保留修订本手册和随时修改本手册内容的权利,无需通知任何人。

*DLP、Digital Micromirror Device 和 DMD 为 T exas Instruments 之商标。

其它则分别为其各自公司或组织的版权。

专利请进入/以了解 BenQ 投影机专利范围的详情。

2 保修及版权信息目录保修及版权信息 (2)重要安全说明 (4)简介 (7)物品清单 (7)投影机外观视图 (8)控制按钮和功能 (9)投影机定位 (11)选择位置 (11)获取首选的投影图像大小 (12)吊挂投影机 (13)调节投影图像 (14)连接 (16)连接智能设备 (17)操作 (18)启动投影机 (18)使用菜单 (20)投影机安全 (21)切换输入信号 (23)关闭投影机 (23)直接关闭电源 (23)菜单操作 (24)菜单系统 (24)基本菜单 (28)高级菜单 (30)维护 (37)维护投影机 (37)灯泡信息 (38)故障排除 (42)规格 (43)投影机规格 (43)外形尺寸 (44)时序表 (45)RS232 command (48)目录3重要安全说明您的投影机经过设计和测试,符合最新信息技术设备的安全标准。

西门子 Gigaset A680 A685 数字无绳电话系统 说明书

西门子 Gigaset A680 A685 数字无绳电话系统 说明书

s西门子Gigaset A680/A685 数字无绳电话系统使用说明书For the English user manual, please contact us by E-mail: service@or download from:/cn发行单位:集怡嘉通讯设备(上海)有限公司保留所有权利目录安全预防措施 2使用前的准备 3 安装基座 3 连接基座 3 安装手柄 4 注册手柄 5 首次使用充放电 5 设置日期和时间 5手柄/基座简介 6注册手柄7 自动注册 7 手动注册 7 注销手柄 7 呼叫手柄 7ECO模式7拨打/接听/挂断电话 8 拨打/接听 电话 8 结束通话 8 通话保持 8 来电显示 8使用通讯与列表9 通讯录 9 新增条目 9 编辑条目 9 重拨列表 10 来电列表 10 拨号预选 11 使用多个手柄 12 内部通话 12 三方通话 12答录机 13 打开/关闭答录机 13 主人留言 13 播放留言 14 答录机设置 14 远程控制答录机 15手柄设置 16 闹钟设置 16 手柄复位 16基座设置 16系统PIN 16 基座复位 16当电话连接到PABX时的设置 17 拨号方式 17 闪断时间 17 暂停时间 17附录 18菜单树 20字符表 211安全预防措施注意:使用前请仔细阅读安全须知和操作说明。

教您的孩子正确使用话机,以免发生危险。

本说明书中描述的功能并非在所有国家/地区都适用。

$请请本话机使用时可能会影响附近医疗设备的正常工作。

请注意在这些特殊环境中使用的技术要求,例如:在手术室里。

手不请勿在有爆炸危险的环境下使用手柄,例如:汽车喷漆车间。

ƒ 将请按23使用前的准备基座安装请将基座安装在封闭,干燥的室内,工作温度为+5℃至+45℃,并尽量使基座处于房间的中央位置 注意:• 电话机应远离热源和其它电子设备,并避免阳光直射 • 电话机应远离潮湿、灰尘、腐蚀性液体以及蒸汽通话距离通话距离:• 室外空旷无阻碍的情况下约300米 • 室内约50米连接基座请将基座,电源适配器和电话线按照下图所示连接,并将线整理到导线槽内连接充电座(套装适用)请将基座,电源适配器和电话线按照下图所示连接,并将线整理到导线槽内如果您需要拔出电源,请按照右图所示 按住位置1,拔出位置21.电源适配器2.带水晶头的电话线1.连接到充电座2.连接到电源插座4注意:• 基座要始终连接电源,否则电话无法正常使用 • 只能使用配套的电源适配器• 如果需要自行购买电话线,请确保水晶头型号是否正确正确的水晶头连线手柄安装安装电池请参照手柄上标示的正负极正确安装AAA 充电电池按照右图所示安装电池后盖a.插入电池盖顶部b.向下扣住电池盖打开电池后盖请参照下图,用指甲抵住电池后盖末端,用力向上方打开电池后盖 1 未使用2 未使用3 a4 b5 未使用6 未使用5将手柄放在基座上充电并注册将手柄放在基座上充电,正面向前。

CDU-685 Modem安装指南说明书

CDU-685 Modem安装指南说明书

CDU‐685 Modem Installation GuideCDU‐685 Modem InstallationCDU-685 Modem software can be installed on computers with Windows 2000, Windows XP, Windows Vista operating systems.In this manual we describe installation procedure for Windows XP operating system.SetupMake sure you are logged on as administrator.(If you have previous versions of CDU-685 software installed on your computer, uninstall them using Control Panel / Add or Remove Programs. During uninstall keep the modem unplugged from your computer.)Plug your C-motech CDU-685 Modem into any USB port of your computer.This will automatically launch the installation and install required drivers plus C-motech CDU-685 User program.If automatic installation is not working, please double click the Setup.exe located on the virtual "CD Drive" in modem’s flash memory:Setup process may last several minutes. Follow instructions on computer screen. After installation is complete, please wait till all drivers are installed. During entire installation process do not unplug the modem from USB port of your computer.Install Shield Wizard... click 'next'Choose the installation directory and click "Next" to continue.Click "Next" to continue.Click "Install" to continue.C-motech CDU-685 Modem is configuring your new software installation and copying files.Installation Complete. Click “Finish”.Please wait until all drivers are installed. This may take a few minutes. During this time do not unplug the modem from USB port of your computer:Step 1 ‐ CMOTECH CDMA Technologies InstallStep 2 ‐ USB Data Modem Driver (CMO6004) InstallStep 3 ‐ USB Serial Port Driver (CMO6004) InstallStep 4 ‐ USB Serial Port2 Driver (CMO6004) InstallModem Driver Install FinishedFranklin Connection ManagerUser GuideCDU685 USB ModemUsing the Franklin Modem Application SoftwareDuring this installation a Shortcut will have been placed on your desktop for the Franklin Data Modem Application software.On start of the Application Software, the first screen you will see is the Main window.MainIndicator state IconsTaskbar IconClick the ‘Connect’ button. The Application Software will start dialing when the button is clicked.Verifying User.You can see above window’s black arrow with red color icon. This arrow icon is shown on connection.Warning: If you install Windows XP service pack 2, you must turn off firewall in Window security center.If you try connecting with turn on firewall, you can see connecting fail.Click the Windows taskbar's shield - shaped Yellow icon, you can see Window Security centerClicking the disconnect button <STOP> on the Main window or Dial up slide window, will disconnect the dialup connection and the modem will switch to idle mode.OptionConnection History: The User Data Counter will continuously accumulate on each session and will only clear when “Clear” is clicked.Device Info Diagnostics: You can use this window to get information about your 1xEV-DO devices.HelpSetting ‐ General‐ Connection- Zero CDCONNECTION HISTORYThe User Data Counter will continuously accumulate on each session and will only clear when “Clear” is clicked.Device info DiagnosticsYou can use this window to get information about your Franklin CDU685 device.System InformationGeneral1. Play sound effects2. Always on top3. Start in system tray4. Keep Connection History5. Launch when Windows starts6. Use hibernation: With the Application Software running (idle). Windows will not hibernate or switch to standby mode.Please select this option under General tab to close UI automatically so that windows can hibernate or switch to standby.ConnectionGo automatically when readyData ModeTo change connection type, click the radio Button.NOTE : You can use Packet, QNC type in 1X current coverage but cannot use Packet type in IS 95 coverage.Service Mode ‐ PacketAlways On is a CDMA 1x internet domain that applies to data (in Kilobytes) based charging packages.This service allows you to remain connected to the internet all the time.Charges will apply to the amount of data sent and received with this domain.Service Mode ‐ CircuitWhen you are not within CDMA 1x coverage or you have not subscribed to CDMA 1x, you can still connect to operator's Standard Mobile internet Service using Circuit, provided you are within CDMA coverage.Circuit does not require a separate subscriptionZero CD1. Click Menu on the Fraklin Connection Manager Interface.2. Select settings from the submenu.3. Select Zero CD from the submenu.Settings ‐ Zero CD1.Factory default setting: Zero CD Only and Zero CD Enable.ers for Window 2000 and Window XP limited user should set it to “Modem Only”.FCC Compliance InformationThis device complies with Part 15 of FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and(2)This device must accept any interference received including interference that may causeundesired operation.Body worn operationSAR compliance has been established in the laptop computer(s) with Horizontal and Vertical slot configurations, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristicsThe antenna(s) used for this USB dongle must not be co-located or must not operate in conjunction with any other antenna or transmitter within a host device.WarningsThis equipment has been tested and found to comply with limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment can generates, uses, and radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.Of this equipment does cause unacceptable interference to radio and television reception, which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures.z Reorient or relocate the receiving antenna.z Increase the separation between the equipment and receiver.z Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.z Consult the dealer or an experienced Radio/TV technician for help.CautionChanges or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Port explanationRF_CON1000 : Primary RF conduction test switchCON100 :Micro-SD Memory socket。

PowerLite 685W WXGA 3LCD 超短投影展示屏说明书

PowerLite 685W WXGA 3LCD 超短投影展示屏说明书

EducationSPECIFICATION SHEETPowerLite ®685W WXGA 3LCDUltra Short-throw Presentation DisplayThe ultimate ultra short-throw presentation display for BYOD classrooms.Remarkable color accuracy — 3LCD, 3-chip technology delivers high Color Brightness and a wide Color GamutBright display — 3,500 lumens color/white brightness 1Amazing, widescreen images — native WXGA resolution (1280 x 800) and 16:10 formatLong-life lamp — lasts up to 10,000 hours in ECO Mode 2Ultra short-throw presentation display — get a 100" image from as little as 11" away with virtually no shadow interferenceSimultaneously display and control multiple device screens — wirelessly share BrightColor Brightness: 3,500 lumens 1 White Brightness: 3,500 lumens 1Shown with optional wall mount (sold separately)Specification Sheet | Page 2 of 2Epson America, Inc.3840 Kilroy Airport Way, Long Beach, CA 90806Epson Canada Limited185 Renfrew Drive, Markham, Ontario L3R 6G3 www.epson.caVertical: ±3 degrees Horizontal: ±3 degreesMac Connectivity Projector is Mac compatible via USB; DVI to HDMI or VGA adapter (not included); DP to HDMI or VGA adapter (not included)Contrast Ratio Up to 14,000:1Color Reproduction Up to 1.07 billion colorsProjection LensType Digital zoom/Manual focus F-number 1.6Focal Length 3.7 mmZoom Ratio Digital zoom: 1.0 – 1.35OtherDisplay Performance NTSC: 480 linesPAL: 576 lines (Depends on observation of the multi-burst pattern)Input Signal NTSC/NTSC4.43/PAL/M-PAL/N-PAL/PAL60/SECAMSpeaker 16 W (mono)Operating Temperature 41 ˚ to 104 ˚F (5 ˚ to 40 ˚C) Power Supply Voltage 100 – 240 V ±10%, 50/60 Hz Power Consumption 373 W (Normal Mode) 324 W (ECO Mode)2.2 W Standby (Communication On) 0.23 W Standby (Communication Off)Fan Noise35 dB (Normal Mode) 29 dB (ECO Mode)Security Kensington-style lock provision, padlock and security cable hole, Password-protect functionExcluding Feet 14.5" x 15.8" x 5.9"Weight 12.6 lbRemote ControlFeatures Source Search, HDMI/Video, LAN, Computer, USB, Power, Aspect, Color Mode, Volume, E-zoom, A/V Mute, Freeze, Menu, Page Up and Down, Home, Auto, Mouse Functions, User, Split Screen 6Operating Distance Front/rear: 19.7 ft (6 m)Eco FeaturesRoHS compliant Recyclable product 7Epson America, Inc. is a SmartWay ® Transport Partner 8SupportEpson Connection SM Pre-sales supportU.S. and Canada: 800-463-7766 Service Programs 2-year projector limited warranty, Epson Road Service program, PrivateLine ® dedicated toll-free support and 90-day limited lamp warrantycontrol, batteries, user manual CD, projector software CDs, Quick Setup Sheet, Installation Guide, template sheet, projector feetOrdering InformationPowerLite 685W V11H744520Genuine Epson Lamp V13H010L91Air Filter (ELPAF49)V13H134A49 PowerLite Pilot ™ 2 (ELPCB02) V12H614020Active Speakers (ELPSP02)V12H467020Wireless 802.11 b/g/n LAN Unit (ELPAP10) V12H731P02Epson DC-21 Document Camera (ELPDC21) V12H758020100" WhiteboardV12H831000Ultra Short-throw Wall Mount (ELPMB46)V12H777020Specifications and terms are subject to change without notice. EPSON, EasyMP and PowerLite are registered trademarks, EPSON Exceed Your Vision is a registered logomark and Better Products for a Better Future and Epson iProjection aretrademarks of Seiko Epson Corporation. PrivateLine is a registered trademark, Pilot is a trademark and Epson Connection is a service mark of Epson America, Inc. Mac is a trademark of Apple Inc., registered in the U.S. and other countries. Android and Chromebook are trademarks of Google Inc. SmartWay is a registered trademark of the U.S. Environmental ProtectionAgency. All other product and brand names are trademarks and/or registered trademarks of their respective companies. Epson disclaims any and all rights in these marks. Copyright 2019 Epson America, Inc. Com-SS-Oct-13 CPD-52821R2 1/191 Color brightness (color light output) and white brightness (white light output) will vary depending on usage conditions. Color light output measured in accordance with IDMS 15.4; white light output measured in accordance with ISO 21118. |2 Lamp life will vary depending upon mode selected, environmental conditions and usage. Lamp brightness decreases over time.3 Moderator feature is part of EasyMP ® Multi-PC Projection software. |4 For wireless functionality, including via the Epson iProjection™ App, the projector must be configured on a network, either through the Ethernet port on the projector (check model specifications for availability) or via a wireless connection. Check your owner’s manual to determine if a wireless LAN module must be purchased separately to enable a wireless connection. Not all Epson projectors are able to be networked. The Epson iProjection App does not support all files and formats. See for details.|5 Includes one Mobile High-Definition Link ® (MHL) HDMI port. |6 Consult your user manual for input combinations. |7 For convenient and reasonable recycling options, visit /recycle |8 SmartWay is an innovative partnership of the U.S. Environmental Protection Agency that reduces greenhouse gases and other air pollutants and improves fuel efficiency.Learn more about how our products can empower your institution. Visit us at /foreducation/educationContact:。

Get Started EVDO Rev.A USB Modem CDU-685A说明书

Get Started EVDO Rev.A USB Modem CDU-685A说明书

Get Started EVDO Rev. A USB ModemCDU-685ATable of ContentsHow to Use This GuideSection 1: Introducing the EVDO Rev.A USB Modem1A. Introducing the Cox EVDO Rev.A-System Requirements-Package Contents-Care and MaintenanceSection 2: Installing and Using the USB Modem2A. Installing the Software and Drivers2B. Using Your USB Modem-Activating Your USB Modem-Viewing the User Guide-Removing the USB Modem-TroubleshootingSection 3: Technical Specifications, Regulatory and Safety Information, and Warranty 3A. Technical Specifications-Radio Frequency and Electrical Specifications-RF Frequencies-Software Specifications-Environmental Specifications-Mechanical Specifications3B. Regulatory Information-Caution-WARNING (EMI) – United States FCC Information-Operating Exposure Condition3C. Important Safety Information-Important Notice-Safety and Hazards3D. Warranty-Manufacturer's Limited One-Year WarrantyHow to Use This GuideThe advantages of Cox are as clear as each wireless connection you make. With Cox service, we give you what you really want from a wireless service provider—clear connections, easy-to-understand service plans, and self-servicing options for managing your account. All this is designed to make your life easier and worry-free.We know you’re eager to start using your USB Modem CDU-685A right away, and the sections of this guide are designed to help you do just that.The first section gives an overview of the USB Modem CDU-685A package contents.The second section guides you through the steps required to install your USB Modem CDU-685A and the Windows drivers and software, describes how to start the software once it is installed.The third section lists the technical specifications, regulatory and important safety information, and warranty information for your USB Modem CDU-685A.Getting More Information About Your Device and ServiceThis guide describes how to install and start the software. To learn how to use all the features of your USB Modem CDU-685A and software, consult the user guide or online help.Section 1 : Introducing the EVDO Rev.A USBModemSection 1A : Introducing the Cox EVDO Rev.A USB ModemThis section introduces your USB Modem CDU-685A, and describes what is included with your device.The USB Modem CDU-685A is a wireless USB modem.Using this device, and subject to network availability, you can:•Easily activate your account•Connect to the Internet and to VPN and corporate networks•Send and receive large email messages•Download media content (music, videos and real-time and streaming media)•Play games onlineSystem RequirementsThis Cox Mobile Broadband USB modem is supported on:•Windows Vista.•Windows XP with Service Pack 2 or later.•Windows 2000 with Service Pack 4 or later.•Windows 7To install and run the USB modem and the accompanying Cox Connection Manager SM software, you will need:a free USB slot.• a minimum of 256 MB of memory using Windows 2000 and Windows XP.• a minimum of 1 GB of memory using Windows Vista.• a minimum of 70 MB of free space on your hard drive.• a minimum processor speed of 300 MHz for Windows 2000 and Windows XP.• a minimum processor speed of 800 MHz for Windows Vista.*Note : You can connect your device to any computer (desktop or laptop) with a USB slot.Package ContentsUSB Modem CDU-685A package contains the following components:•Cox EVDO Rev.A USB Modem CDU-685A•Get Started guide•Installation CDCare and MaintenanceAs with any electronic device, USB modem must be handled with care to ensure reliable operation. Follow these guidelines in using and storing the USB modem:•The USB modem should fit easily into an available USB slot. Forcing the device into a slot may damage the connector pins.•Protect your USB modem from excessive moisture and heat, and from prolonged exposure to the sun.•When it is not connected to your computer, store your USB modem in the pouch that came with the modem to avoid dust.•Remove your USB modem before storing or transporting your computer.•When inserting or removing your USB modem, always grip from the sides rather than the end, as this prevents damage to the USB modem.•Do not use your USB modem while driving a vehicle, as it may distract you from properly operating the vehicle.•Dispose of your USB modem in accordance with EPA guidelines. For more information, visit /epawaste/partnerships/plugin/cellphone/index.htm.Section 2 : Installing and Using the USB ModemSection 2A : Installing the SoftwareInstalling the Software and Drivers1.Insert the installation CD into your CD-ROM drive. The CD should launch automatically. Click Setup tocontinue. (If autoplay is disabled, navigate to your CD-ROM drive in Explorer and click setup.exe.)2.In the “Welcome to the InstallShield Wizard” installation window, click Next.3.Read the License Agreement and select “I accept the terms in the License Agreement”to agree to theterms. Click Next.4.Select a skin (“New”or “Classic”) and click Next.5. In the “Destination Folder” window, click Next to accept the default installation folder (recommended); or click Change, specify a different installation folder, and then click Next to continue.6. Click Install to begin installation.7. When the “InstallShield Wizard Completed” window appears, click Finish.8. If a message that you must restart your computer is displayed, click Yes to restart your computer. Wait until your computer restarts.9. Proceed to Activating Your USB Modem.Section 2B : Using Your USB ModemActivating Your USB ModemIf your USB modem has not been preactivated or you have not activated it at the time of purchase, you must activate your account and configure the USB modem to use your account. (Normally, your device will automatically complete the activation process the first time you use it.)1.Gripping both sides of the USB modem, insert it into your computer’s USB port. Windows detectsthe USB modem and installs the drivers for it. This may take a few minutes. Once completed, thesystem tray may display “Your devices are ready to use” or “Your new hardware is installed andready to use.”unch Connection Manager by double-clicking the program’s icon.3.Hands Free activation starts automatically and will be displayed on the Cox. After the activationsuccessfully completes, it will automatically connect and welcome you to the Cox Network.4.If activation was not successful, a message window is displayed. For instructions on activating yourUSB modem, see the user guide (see “Viewing the User Guide”). Use the spaces below to writedown important information related to the activation process and your account.ESN/MEID______________________________________Activation code__________________________________Cox Phone number____________________________MSID__________________________________________Account password_______________________________Cox User Name________________________________Viewing the User GuideThe user guide provides detailed information on the Cox Connection Manager software.On your computer, select Start > All Programs > Cox > Connection Manager > Users Guide.On your computer, select Start > My Computer. Right click on CD/DVD RW Drive and select EXPLORE > UserGuide.Removing the USB Modem1.Disconnect from the Cox Connection Manager software if it is running.2.Remove the USB modem from your computer’s USB slot by gripping both sides of the USB modemand pulling straight out.Troubleshooting1. For a more complete listing of errors and possible solutions, please see the user guide or online Help. You may also call Cox Customer Service.2. Ensure that the Connection Manager software has been successfully installed on your computer.3. Ensure that your USB modem has been activated.4. Ensure that the USB modem is fully plugged into the USB slot.5. Ensure that the LED light is on; otherwise connect and then reconnect the USB modem.Section 3 :TechnicalSpecifications, Regulatory and SafetyInformation, and WarrantySection 3A : Technical SpecificationsRadio Frequency and Electrical SpecificationsFrequencies CDMA 800/AWS/1900 MHz Interface Type High-Speed USB 2.0 compliant Common air interface CDMAAntenna Diversity Support Receive DiversityDC input operating voltage +5VDC from USB host port Maximum current @+5VDC Under 500mARF FrequenciesBC0TX frequency: 824MHz – 849MHzRX frequency: 869MHz – 894MHzBC1TX frequency: 1850MHz – 1910MHzRX frequency: 1930MHz – 1990MHzAWSTX frequency: 1710MHz – 1755MHzRX frequency: 2110MHz – 2155MHzSoftware SpecificationsOS Support Windows® 2000, XP, Vista and Windows 7Environmental SpecificationsOperating conditions -20°C ~ +55°C , 85%(at 50(°C)), relative humidity (non-condensing) Storage Temperature -35°C ~ +75°CHumidity 95%, non-condensingMechanical SpecificationsDimensions 32.1mm * 72.1mm * 11.9mmWeight Approx. 23gForm Factor USB Series “A” Type plugHousing Material CASE – PCSection 3B : Regulatory InformationThis device is compliant with Parts 15, 22, 24, and 27 of the FCC Rules. Operation of this device is subject to the following two conditions:1. This device may cause harmful interference.2. This device must accept any interference received, including interference that may cause undesirable operation. FCC ID: TARCDU-685ACAUTIONUnauthorized modifications or changes not expressly approved by manufacturer could void compliance with regulatory rules and thereby your authority to use this equipment.WARNING (EMI) – United States FCC InformationThis equipment has been tested and found to comply with the limits pursuant to Parts 15, 22, 24, and 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in an appropriate installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.Operating Exposure ConditionSAR compliance has been established in the laptop computer(s) with Horizontal and Vertical USB slot configurations, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics.Section 3C: Important Safety InformationImportant NoticeBecause of the nature of wireless communications, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors), or be totally lost. Although significant delays or losses of data are rare when wireless devices such as the Cox EVDO Rev.A USB Modem CDU-685A are used in a normal manner with a well-constructed network, they should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party, including but not limited to personal injury, death, or loss of property. Manufacturer accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the Cox EVDO Rev.A USBModem CDU-685A, or for failure of Cox EVDO Rev.A USB Modem CDU-685A to transmit or receive such data.Safety and HazardsDo not operate modem in areas where blasting is in progress, where explosive atmospheres may be present, near medical equipment, life support equipment, or any equipment which may be susceptible to any form of radio interference. In such areas, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. It can transmit signals that could interfere with this equipment. Do not operate the Cox EVDO Rev.A USB Modem CDU-685A in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. When operating, it can transmit signals that could interfere with various onboard systems. The driver or operator of any vehicle should not operate the Cox EVDO Rev.A USB Modem CDU-685A while in control of a vehicle. Doing so will detract from the driver or operator’s control and operation of that vehicle. In some jurisdictions, operating such communication devices while in control of a vehicle is an offense.Section 3D : WarrantyManufacturer’s Limited One-Year WarrantyThe company warrants to original retail purchaser of this device, that should product during normal consumer usage conditions, be proven defective in material or any part thereof, during normal consumer usage conditions, be defective in material or workmanship that results in product failure within the first twelve (12) month period from the date of purchase, such defects will be repaired or replaced (with new or refurbished) product at the Company’s discretion, without charge for parts and labor directly related to the defect(s). This warranty extends to consumers who purchase the product in the United States or Canada and it’s not transferable or assignable. This warranty does not apply to:(a) Product subject to abnormal use or conditions, accident, mishandling, neglect, unauthorized alteration, misuse, improper installation or repair or improper storage;(b) Products whose mechanical serial number or electronic serial number has been removed, altered, or defaced;(c) Damage from exposure to moisture, humidity, excessive temperature or extreme environment conditions;(d) Damage resulting from connection to, or use of any accessory or other product not approved or authorized by the company;(e) Defects in appearance, cosmetic, decorative or structural items such as framing and non-operative parts;(f) Product damaged from external causes such as fire, flooding, dirt, sand, weather conditions, battery leakage, blown fuse, theft or improper usage of any electrical source.The Company disclaims liability for removal or reinstallation of the product, for geographic coverage, for inadequate signal reception by the antenna or for communications range or operation of the cellular system as a whole.When sending your wireless device to authorized distributors for repair or service, please note that any personal data or software stored on the device may be inadvertently erased or altered. Therefore, we strongly recommend you make a back up copy of all data and software contained on your device before submitting it for repair or service. This includes all contact lists, downloads (i.e. third-party software applications, games and graphics) and any other data added to your device. Manufacturer is not responsible for and does not guarantee restoration of any third-party software, personal information or memory data contained in, stored on, or integrated with any wireless device, whether under warranty or not, returned to manufacturer’s authorized distributors for repair or service. To obtain repairs or replacement within the terms of this Warranty, the product should be delivered with proof of Warranty coverage (e.g. dated bill of sale), the consumer’s return address, and daytime phone number and/or fax number and complete description of the problem, transportation prepaid, to the Company at the address shown below or to the place of purchase for repair or replacement processing.The extent of the company’s liability under this warranty is limited to the repair or replacement provided above and, in no event, shall the company’s liability exceed the purchase price paid by purchaser for the product.Any implied warranties, including any implied warranty of merchant ability or fitness for a particular purpose, shall be limited to the duration of this written warranty. Any action for breach of any warranty must be brought within a period of 18 months from date of original purchase in no case shall the company be liable for a special consequential or incidental damages for breach of this or any other warranty, express or implied, whatsoever. The company shall not be liable for the delay in pending service under this warranty or loss of use during the time the product is being repaired or replaced.No person or representative is authorized to assume for the Company any liability other than expressed herein in connection with the sale of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts on the exclusion or limitation of incidental or consequential damage so the above limitation or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to province.TrademarksCox and the logo are trademarks of Cox. Other marks are the property of their respective owners. Windows® is a registered trademark of Microsoft Corporation. Copyright ©2009 Cox. Cox and the logo are trademarks of Cox. Other marks are the property of their respective owners.。

HM685 数字流量计用户手册说明书

HM685 数字流量计用户手册说明书

HM685 QUICK START GUIDEEach key and its function are described below.READPress thePRESS Accesses the Pressure measurement screen from the Flow measurement screen.Press the key to turn the HM685 Hydronic Manometer on or off.The HM685 Hydronic Manometer can be powered by four (4) AA-size batteries (alkaline or rechargeable NiMH) or the AC adapter.Locate the battery cover on the back of the unit and loosen the screw to remove. Take out the battery holder and replace with fresh batteries (alkaline or rechargeable NiMH). Ensure that the batteries are correctly oriented within the battery holder and Set the battery-type selection switch to indicate the type of batteries to be used (alkaline or rechargeable NiMH). Reinstall the battery holder and battery cover.The AC adapter allows the HM685 Hydronic Manometer to be powered from a standard AC wall outlet. When using the AC adapter, alkaline batteries (if installed) will be bypassed. The AC adapter also charges the NiMH type batteries (if installed) in the unit.Upon instrument start-up, the user will be prompted to zero the gauge pressure sensor and includes on-screen instructions. Gauge pressure sensor zeroing can also be initiated by selecting Zero Gauge Pressure when in the Main Menu by pressing the ENTER( ) key. The (+) and (-) pressure ports must be open to atmosphere and the valve handle on the manometer set to the MEASURE position.Turn the valve handle on the manometer to the BYPASS position while in the main Measurement Screen to automatically zero the differential pressure sensor. Zeroing of the differential pressure sensor occurs any time the valve handle is turned to the BYPASS position. Any pressures applied to the hoses will not affect the dP zeroing function and allows for zeroing of the differential pressure sensor while maintaining connections to the system under test. Connect the straight female flare fitting on the High pressure (red) hose to the male fitting on the top of themanometer marked with a plus (+) sign. Connect the straight female flare fitting on the Low pressure (blue) hose to the male fitting on the top of the manometer marked with a minus (-) sign. 1. Turn the shut-off ball valve on both the High and Low pressure hoses to the closed position.2. Turn the valve handle on the manometer to the MEASURE position.3. Using an appropriate fitting, connect the open end of the High pressure (red) hose to the test point with the higher line pressure.4. Attach the appropriate fitting to the open end of the Low pressure (blue) hose.5. To ensure all the air is bled from the hoses, hold the open end of the Low pressure (blue) hose in an upright position over a suitable receptacle or near a drain.6. Turn the shut-off ball valve on both the High and Low pressure hoses to the open position.7. Turn the valve handle on the manometer to the BYPASS position to allow the liquid flow to displace the entrained air.8. Once the liquid is flowing steadily from the Low pressure (blue) hose, turn the valve handle on the manometer to the MEASURE position. The HM685 Hydronic Manometer allows for simultaneous and continuous measurement and display of the High-side gauge and Differential pressure. The calculated Low-side gauge pressure is also displayed.Taking a discrete pressure measurement allows for measurement and display of a single time-averaged reading taken over the sampling period as defined by the Log Mode and Log Settings. Discrete measurement values are stored to the memory (current Test ID) and displayed on-screen for a period of four (4) seconds and then returns to continuous measurement mode. Press the READ key to initiate.High SidePressure Temperature Low SidePressure or PowerInput TypeThe manometer makes and displays continuous differential pressure measurements, calculates and displays continuous flow readings, and allows for discrete data storage to the memory when in the Flow measurement screen.Taking a discrete flow measurement allows for measurement and display of a single time-averaged reading taken over the sampling period as defined by the Log Mode and Log Settings. Discrete pressure or flow measurement values are stored to the memory (current Test ID) and displayed on-screen for a period of 4 seconds and then returns to continuous measurement mode. Press the READ key to initiate.The accessory temperature probes are optional for the HM685 Hydronic Manometer and can be connected to the 3-pin mating connector located on the right-hand side of the manometer. The unit of measurement for temperature (°F or °C) is driven by the differential pressure measurement: Differential pressure in psi, inH 2O, ftH 2O, or inHg → temperature in °FDifferential pressure in kPa, mH 2O, mmHg, or bar → temperature in °CPressing the key from either the Pressure or Flow Measurement screens accessesthe Main Menu, select a menu item or accept changes. Use the arrow ▲▼ ◄► keysto navigate through menu items and change selected items.Use Flow Setup to set values for key factors that impact measured flow values.Temperature Current Test IDCurrent Cv Factor NameDifferentialPressureBattery Status orPower Input TypeCv/Kv ValueTSI Incorporated– Visit our website for more information.USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388Access the Data Logging Menu by pressing the DATA key from either the Pressure or Flow Measurement screens or from the Main Menu.Log Mode: HM685 programmable logging formats:Log Settings: defines the period the manometer will log sample readings. When the Log Mode is set to Cont-Time, this setting is also used to define the length of the test in hh:mm:ss.Choose Test: choose the Test where the samples (readings) will be stored.Name Test: customize the Test ID name of the selected test using 10 characters maximum.View Data: choose the data to review.Delete Data: d elete discrete samples, an entire Test ID, or all data stored.Memory: displays the total memory availableThe Calculations Menu is accessed by pressing the CALC key from either thePressure or Flow Measurement screens.Brake Power: determines pump brake power using flow, delta P and pump efficiencyHeat Flow: determines heat flow using temperature, flow, specific heat and gravityCalc Cv/Kv: calculates Cv or Kv based on flow and differential pressurePump Law Impeller Diameter: allows for determination of required pumpimpeller sizePump Law Delta P: determines required pump pressure drop using flow and delta P inputsPump Law Brake Power: determines pump brake power based upon the following affinity law: Pump brake power varies as the cube of flowThe Settings menu allows customization of theinstrument display.。

飞利浦dctg6851b_93_dfu_zhs说明书

飞利浦dctg6851b_93_dfu_zhs说明书

25
7 默认设置
25
8 菜单结构
26
9 常见问题
29
10 索引
31
2
目录
1 重要信息
在您使用 DCTG685 之前请耐心阅读本用户手 册。里面包含了有关电话的重要信息和说明。
1.1 安全信息 没有电源供应时,本设备不能进行紧急呼叫。 必须有替代设备可以进行紧急呼叫。 产品默认个人识别码 (PIN) 为 0000。如果您修 改此密码,请将密码保存在安全且易取得的 地点。切勿遗失个人识别码 (PIN) 代码。 为了避免损坏或者出现故障: • 禁止产品接触液体。 • 禁止打开设备,以防触电。 • 禁止加热或者受阳光直射,以免设备接触
编辑模式:短按下切换大小写字符
J *键
闲置/拨号模式:短按下插入一个 * 符号
闲置模式:长按下激活或者关闭键盘锁定
F
K 呼叫转移/内部呼叫/三方电话
G
闲置模式:短按下开始内部呼叫
外部电话接通期间:短按下开始内部通话
或者在内部和外部通话之间切换通话
长按下与
1.4 再利用和废物处理 废旧产品的处理指示: 您的产品采用高品质材料和部件设计生产, 这些材料部件均可回收再利用。 请了解当地此标记代表的电器和电子产品区 分收集系统。
废旧电池处理指示: 电池不应当和一般性家庭废物一起处理。
包装材料信息: 飞利浦设计标准符号标记包装材料,以促进 对废旧品的适当处理和再利用。
4
您的电话
2.2 电话概述 2.2.1 话机
A 事件 LED
关闭:没有新事件
红灯闪烁:未阅读事件(例:如果您从网
络供应商处申请了来电显示 (CLI),则指示有
未接电话。)
A

网络模块685接警机说明

网络模块685接警机说明

网络模块685接警机一、概述目前IP网络接警是大势所趋,基本主流的报警器厂家都有自己的有线网络模块或gprs无线网络模块。

更有甚者,还出现一种DTMF(CID\4+2)的通用型的网络模块或GPRS模块,这样就大大加快了报警设备网络化的进程。

考虑到目前一些联网报警中心软件是很多年前的产品,用户使用较为习惯,不想或暂时不想更换的,我们据此研发出一款“转换软件”,把各种不同的网络模块、gprs无线模块转换成685串口输出,输出到这些用户的老软件。

二、常用网络模块端口序号模块名称端口号1LX网络模块8090理想2HT网络模块6000宏泰3HT网络模块26002宏泰4HT GPRS模块6001宏泰5HT GPRS模块26003宏泰6KS-MGPRS网络模块9021科立信7KS-Z503A网络转换模块50000科立信8KB-AV28网络摄像机模块9020科立信9KB-1288网络模块9022科立信10FOCUS网络模块7974美安11IP2300网络模块5000德尚安12NAL2300网络模块4001海康\迈特安13IPM网络模块3000Honeywell14ZLA网络模块2011正林安15思科瑞网络模块6501思科瑞16飞腾网络模块7200飞腾17ALA网络模块2332艾礼安18AS-9000网络模块9000顺安居19DA2300、2500网络模块8060东昂20LX终端8090理想21好士佳平安钟4050好士佳22B426-CN/B4207700(UDP)博世上述端口未注明的都是TCP端口。

上述端口号是我们总结的各厂家的缺省端口号,如有出入,请用户自行设定。

三、软件安装说明首先找到上述安装文件。

运行如下:四、685接警机使用说明可看到windows桌面上的快捷方式,点击运行设置686串口及波特率开机自动运行表示windows启动登录后,本程序可自动运行。

输出来电显示表示用685协议可输出网络模块的IP地址。

A-685掩膜支架安装提示说明书

A-685掩膜支架安装提示说明书

A-685Mounting Bracket ➤Suction Service ValveInstallation TipsRemove the flange plate, spacer plates, springs and cardboard separators before brazing the suction filter shell into the line. The connections on the shell are copper and can be installed with all normal soldering or brazing material including soft solder, Sta-Brite, Easy-Flo, silver brazing alloys, Sil-Fos or Phos-Copper. For best results, wrap a wet rag around the end of the shell and direct the flame of the torch away from the shell while brazing . In this way one can avoid damaging the paint on the shell andmaintain proper protection from corrosion.screwed into the 1/4" NPT hole in the flange plate. Pipe dope (preferably teflon tape) should be used on the threads to prevent leakage. Then install the access valve core in this fitting. After installation in the suction line, with the side fitting as the inlet,the access valve permits measuring the pressure drop from theupstream side of the filter to the gauge connection on the com-pressor suction service valve, and thus determining if the filter element is plugged. When the access valve is not in use, keep it capped to avoid possible leaks.ReplaceableBEFORE INSTALLINGSporlan Replaceable Suction Filters can be installed in either flow direction , whichever is simpler for piping the individual job. The unit may be installed in either a vertical or horizontal line. However, it is advisable to mount the shell so foreign material cannot drop into it when the elements are removed. Also avoid installing the shell in such a manner that it traps an excessive amount of oil.CAUTION: The Replaceable Suction Filter must be installed with the side fitting as the inlet when Catch-All ® cores are used. This also provides the use of the access valve for pressure drop measurements.When making the installation allow 6-3/4" beyond the flange plate for pull space in removing the filter element. Since the elements are installed in a "muzzle loading" fashion, the pull space is the same for shells using two elements as for the shells using one element.The Sporlan A-685 mounting bracket should be used to support the shell to avoid undue strain on the refrigerant piping.®The filter elements (purchased separately) are installed in place of the cardboard spacers shipped with the unit. Detailed instructions for installing the elements are given on the filter element package. Inspect the edge of the shell and the gasket surface immediately before installing the flange plate to obtain a clean, leak-tight joint. A new gasket is supplied with each filter element. It is recommended that this gasket only be replaced if it is damaged.THE PROPER FILTER ELEMENTThe Sporlan RPE-48-BD Filter Element is recommended for use in all Replaceable Suction Filters. The pleated paper filter element will collect a very large amount of dirt before plug up occurs. This element is suitable for flow in either direction.CATCH-ALL CORES (RC-4864, RC-4864-HH or RCW-48) can be used in Replaceable Suction Filters if certain precautions are followed. The side fitting must be the inlet. Also a special 100 mesh screen (Sporlan Part No. 6171-5) must be obtained from your wholesaler and installed in the outlet end of the core assembly. It is placed between the core and spacer plate at the outlet end as shown in the diagram. This screen will collect any Flow ➠If a bolt is lost or a nut is stripped while installing the flange plate, be sure to obtain a replacement. Installing the flange plate with less than the proper number of flange bolts will very likely result in a refrigerant leak, and could result is an explosion hazard. The bolts should be tightened to a torque value of 14-16 ft. lbs.© C OPYRIGHT 2004 BY S PORLAN V ALVE C OMPANY , W ASHINGTON , M ISSOURISD-107-604P RINTED IN U.S. OF A.FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLYThe Replaceable Suction filters are not recommended for use at temperatures below - 50°F. The Sporlan Replace-able Suction Filters are recommended for use in the suc-tion line of R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-502, R-507, and similar halocarbon refrigerant systems.small particles that might be rubbed off the core during assem-bly. The screen should be removed with the molded cores when cleanup is complete. The screen should not be used when filter elements are used.No. 6171-5。

迅达xd-685操作规程

迅达xd-685操作规程

上海迅达XD-685电解质分析仪操作规程1 仪器名称及型号仪器名称:钾/钠/氯/钙/PH分析仪型号:XD6852 生产厂家上海迅达医疗仪器公司3 检测范围适用于直接测量生物样品如:血清、血浆或全血及脑脊液、稀释尿(只测K、Na、Cl三项)等其它生物体液的钾、钠、氯、离子钙、标准化离子钙和PH值。

4 检测原理XD-685分析仪采用离子选择性电极的测量原理来测量样品中的K+、Na+、Cl-、iCa2+和H+。

利用了比较法即先测量二个已知浓度的标准液(定标/冲洗联用液和斜率标准液)中K、Na、Cl、iCa和H的电极电位,在仪器程序内建立一条校准曲线,然后再测量样品溶液中K+、Na+、Cl-、iCa2+和H+的电极电位,从已建立的校准曲线上求出样品溶液中K+、Na+、Cl-、iCa2+和H+的离子浓度(mmol/L)。

数据直接显示在液晶显示器上或用内置打印机打印出测量报告。

5 参数设置仪器开机进入主菜单,按“5”进入系统菜单;在系统菜单界面,按“1”进入设置界面,然后根据用户的要求对仪器的时钟、样品类型、测定方式及仪器测试样品的参考范围进行设置。

6 开、关机程序6.1 开机:685分析仪需要24小时连续开机,如果断电后进行日常维护需要30分钟的仪器稳定时间。

注意:如果较长时间关机的话,685分析仪的电极需拆下,用蒸馏水冲洗电极管道并吸干,装盒保存。

6.1.1 打开仪器面板,将废液瓶安装到左起第一个位子上6.1.2 将定标/冲洗液取样管装入定标/冲洗液瓶子中,然后安装在左起第二个位子上。

6.1.3 将斜率定标液取样管装入斜率定标液瓶子中,然后安装在左起第三个位子上。

6.1.4 接通电源,仪器前面板右上方的电源指示灯亮,约1分钟后仪器进行工作状态检查,并冲洗管道。

6.1.5 冲洗结束,仪器进行mv值检查、定标。

并自动打印输出各电极的mv值、斜率,提示可以进行样品的测试。

6.2 关机:关闭电源,倾倒废液。

7 操作程序7.1 在仪器主菜单下按“3”键进入测量操作7.2此时按仪器“CLR”键可以从后一位清除样品编号,然后按数字键可以重新输入新的样品编号,输完编号后抬起吸样针;如不输入样品编号,直接抬起吸样针。

SD6855 6 LED驱动原边控制开关电源说明书

SD6855 6 LED驱动原边控制开关电源说明书

杭州士兰微电子股份有限公司
Http: //
版本号:0.2 2010.11.01 共7页 第7页
IPK ;
ISP 为次级线圈的峰值电流,IPK 为原级线圈的峰值电流,n 为原次级线圈的匝比。 因此,在峰值电流恒定的条件下,只需要保持 TOFF1=TOFF2+TON 即可实现输出的恒流。
杭州士兰微电子股份有限公司
Http: //
版本号:0.2 2010.11Fra bibliotek01 共7页 第4页
版本号:0.2 2010.11.01 共7页 第2页
SD6855/6 说明书
极限参数(除非特殊说明, Tamb=25°C)


供电电压
内部电源电压
FB输入电压
其他输入电压
输入电流
工作结温
工作温度
贮存温度
ESD(人体模式)
符号 VCC VREF5V VFB VIN
IIN TJ Tamb TSTG ESD
关断阈值电压
内部供电电源
反馈部分
使能开启电压
过压保护电压
环路开路保护电压
动态特性部分
前沿消隐时间
过压保护恢复时间
限流部分
峰值电流检测阈值
过温保护部分
过热检测
过热迟滞
符号
测试条件
IST IOP VST VSP VREF5V
VCC =14V
VEN VOVP VBLANK
TLEB TOVP
VPK
Tsd Tsdhys
Http: //
版本号:0.2 2010.11.01 共7页 第3页
SD6855/6 说明书
功能描述
SD6855/6是离线式高端开关电源控制器。通过检测变压器原级线圈的导通时间TON、副边线圈放电的时 间TOFF1和衰减振荡的时间TOFF2,来实现输出恒流。

NSR68XRF-D0X综合测控装置技术使用说明书_v3.00

NSR68XRF-D0X综合测控装置技术使用说明书_v3.00
-2-
NSR68XRF-D0X 综合测控装置技术使用说明书
(10)具有手动同期和自动同期功能,在液晶对话窗口可对同期功能进行投退; (11)在液晶菜单项可整定五防闭锁、顺序控制、间隔间联锁功能。
1.1 NSR68XRF-D0X 综合测控装置硬件基本组成及原理
NSR68XRF-D0X 综合测控装置硬件由 CPU 模件、电源模件、I/O 模件、测量模件、 人机接口模件组成。CPU 模件主要由 TI 的 32 位 DSP TMS320F28335、16 位 AD 芯片、 E2PROM 等组成,TMS320F28335 支持浮点运算,运行速度快。电源模件根据装置通信 方式不同分为三种:PWRA(双 CAN)、PWRM(CAN+RS485/RS422)、PWRN(双以太网)。 I/O 模件根据不同型号不同配置方式分为如下几种:YX、YK、YXK、YXC、YKC、YKG1、 YKG2、YKG3、YKG4、YKI1、YKI2、YKI3、YKI4、YXKG1、YXKG2、YXKG3、YXKG4、YXG2、 YXG4、YXI2、YXI4、YXKGS2、YXKGS4、YKGS2、YKGS4、SYXG1、SYXG2、SYXG3、SYXG4、 DYXG4。测量模件分为三种:ADC17、ADC18、ADC19。CPU 模件与其它模件之间连接通 过高速并行总线方式实现。各模件功能如下表 1.1.1:
NSR68XRF-D0X 综合测控装置除完成常规的测量、记录、监视、控制、同期外, 还可实现丰富的五防闭锁、顺序控制、间隔间联锁等功能,它充分满足各种电压等 级的电厂、变电站对实现综合自动化和无人值班的要求。
NSR68XRF-D0X 综合测控装置在硬件设计、软件设计、用户接口接线、变电站信 息共享、通信接口等方面均作了一些优化处理,在设计思想上遵循集散系统设计原 则,以强化系统运行安全、简化系统维护操作、提高性能价格比为设计目的。在设 计过程中充分考虑了装置的恶劣运行条件,装置抗震性能好,工作环境温度宽,抗 电磁干扰能力强。

685使用说明书

685使用说明书

685使⽤说明书ADEMCO 685 数字通讯接收机安装使⽤⼿册⽬录:1. 安装程序 12. 使⽤介绍(图5) 53. 通讯格式之定义74. 附件:91. 安装程序1.1. 旋开685 上盖的四颗镙丝1.2. 由於运输途中,可能使分别在板槽J1,J3及J5的显⽰驱动器卡,记忆体卡及中央处理器卡与板槽接触不良,因此必须使⽤各电路板两端⽩⾊的启出杆启出各电路板,再重新插⼊以确保各电路板与板槽接触正常.(图1)1.3. 检查各接线插头接触良好(如将来685 需要移动,也需要重覆此步骤1⾄3)1.4. 记忆体卡的安装(图2)1.4.1.将写有"685C" 的691 PROM芯⽚依图2插⼊记忆体卡之691 晶⽚槽内。

注意红⾊三⾓形在左下⾓⽅向1.4.2.依图2和你的周边设备设置跨接线位置1.5. 电话线卡(图3)1.5.1.将电话线卡由板槽J6 起插⼊1.5.2.连接电话接头1.5.3.调整组别号码旋钮开关(如电话线卡#1调为1,电话线卡#2调为2.....)此号码会显⽰在前板数字发光⼆极管GRP.NO. 处1.6. 685接线(图4)1.6.1.连接电话线1.6.2.连接并⾏式打印机(J105). 开启打印机电源(某些打印机其PIN9 必须和PIN16 连接起来才能正常操作)1.6.3.连接外接警号(J104为常闭开关输出,开关最⼤额定值为12 伏特直流2安培)(需外接电源12VDC)1.7. 检查以上各步骤,证实⽆误後连接电源(220VAC,50Hz) 1.8. 这时685被启动,各指⽰灯闪亮,打印机会打印出⼀段⽂字1.9. 接⼊後备电池(J106,J107为并联)后⾯前⾯图 1 685机内俯视图图3 电话线卡电源模块检测串⾏式打印机(20脚为准备好线):跨线2和3 检测串⾏式打印机(21脚为准备好线):跨线1和2 不检测串⾏式打印机:出⼚时设置(跨线4和5)图2 记忆体卡设置2. 使⽤介绍(图5)2.1. 前板按钮功能2.1.1.AUTO/MANUAL ⾃动/⼿动开关a. 在AUTO ⾃动位置,如周边设备,如打印机,操作正常,则所有信息将⾃动输出.b. 在MANUAL ⼿动位置,任何信息将被储存在685记忆体中,直⾄操作员按下DISPLAY NEXT MESSAGE 显⽰下⼀信息键* 在AUTO ⾃动位置时,如685检测到周边设备故障,将⾃动切换⾄MANUAL⼿动模式. 685⾃动⽅式还与打印机、电脑选⽤设置及检测开关设置有关。

godox TT685s 迅丽ttl机顶闪光灯说明书

godox TT685s 迅丽ttl机顶闪光灯说明书

迅丽TTL 机顶闪光灯Thinklite TTL Camera FlashINSTRUCTION MANUAL 说明手册中英文双语 / Chinese English Bilingual在使用本产品之前:请先仔细阅读本手册,以确保您能安全使用。

请保存好本手册以备将来查询参考。

For SonyBefore using this product:Please read this user manual carefully in order to ensure your safety and the proper operation of this product . Keep for future reference.705-TT685S-00地址/Add: 深圳市宝安区福永镇福洲大道西新和村华发工业园A4栋Building A4, Xinhe Huafa Industrial Zone, Fu zhou RD West, Fuyong Town, Baoan District, Shenzhen 518103, China电话/Tel: +86-755-29609320(8062) 传真/Fax: +86-755-25723423邮箱/E-mail:***************深圳市神牛摄影器材有限公司GODOX Photo Equipment Co., Ltd.Made In China感谢您购买神牛产品。

该型号机顶闪光灯适用于SONY 系列相机,兼容TTL 自动闪光。

使用TTL 闪光灯,您将获得更简单的拍摄体验,在光线变化复杂的情况下,可以自动获得准确的闪光曝光,拍摄轻松自如。

产品特点突出表现在以下几方面:● GN 60 (m ISO 100, @200mm), 22级调光(1/1~1/128)● 兼容索尼相机TTL支持TTL 自动闪光,可作为无线多灯闪光系统的主控或从属单 元,拍摄更简单快捷● 点阵液晶屏显示直观,操作更加简易● 内置2.4G 无线传输收发一体,超远距离,创意无限● 无线功率遥控触发选购FT-16S 遥控器,可对离机闪光灯进行无线功率调节等参数 设置,同时触发引闪● 功能齐全,无限享用支持手动和频闪闪光模式,高速同步/第二帘快门同步/闪光曝 光补偿等TTL 功能● 光学研究,输出稳定高速连闪,每次输出亮度和色温连续一致(5600±200K),光线 均匀分布● 固件升级,兼容无忧跟随原厂相机步伐,可对软件进行再升级前言请保持干燥。

DA-685系列产品配件兼容性指南说明书

DA-685系列产品配件兼容性指南说明书

DA-685 SeriesComponent Compatibility GuideA list of peripheral components suitable for use with the DA-685 series of computers2016/07/05 Version 2.0Copyright Notice©2016 Moxa Inc.All rights reserved.TrademarksThe MOXA logo is a registered trademark of Moxa Inc.All other trademarks or registered marks in this manual belong to their respective manufacturers.DisclaimerInformation in this document is subject to change without notice and does not represent a commitment on the part of Moxa.Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.This document might contain unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.Technical Support Contact Information/supportMoxa AmericasToll-free: 1-888-669-2872 Tel: +1-714-528-6777 Fax: +1-714-528-6778 Moxa China (Shanghai office) Toll-free: 800-820-5036Tel: +86-21-5258-9955Fax: +86-21-5258-5505Moxa EuropeTel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa Asia-Pacific Tel: +886-2-8919-1230 Fax: +886-2-8919-1231Moxa IndiaTel: +91-80-4172-9088 Fax: +91-80-4132-10451. IntroductionThis document lists hardware components that are proven to provide the performance listed in the specification when used with the Moxa DA-685 series of embedded computers, or computers that share basic design features with the DA-685 series. Moxa computers come with multiple peripheral options and are engineered to work with components having different hardware specifications. This flexibility could sometimes lead to compatibility issues. When used with the DA-685 series of embedded computers, peripherals from one manufacturer may not work as well as the ones made by another manufacturer. Moxa provides this list of DA-685 series-compatible components, so that users can be certain of a reliable performance from the DA-685 series, when used with the components listed in this document.2. Testing MethodsTo validate that a component meets the Moxa standards for quality and performance, the following five key compatibility tests are run:•Ambient temperature burn-in•Low temperature hard start•Heat/humidity burn-in•Cyclic high-low temperature burn-in•Vibration testAmbient Temperature Burn-InThe component is mounted on to a DA-685 computer and put through a series of stress tests at an ambient temperature of around 25˚C, for a specified period of time. The duration of the test is determined based on the class of peripherals being tested.Low Temperature Hard StartThe component is mounted on to an unpowered DA-685 computer and then the system is booted up at an extremely low temperature. The designated low temperature value depends on the computer model being tested.Heat/Humidity Burn-InThe component is mounted on to a DA-685 computer, placed in a temperature- andhumidity-controlled enclosure, and then put through the burn-in test for a specified period of time. The temperature, humidity, and time targets vary depending on the specification of the computer model used in the test.Cyclic High-Low Temperature Burn-InThe component is mounted on to a DA-685 computer, placed in a temperature controlled enclosure, and then put through the burn-in test wherein the temperature is cyclically varied from very high to very low and back again, over a specified period of time. The target temperature range and the duration of the test can vary depending on the specification of the computer model used in the test.Vibration TestThe component is mounted on to a DA-685 computer that is bound inside an electromagnetic vibrator, and then put through random vibration tests along three orthogonal axes: longitudinal, transverse, and vertical. The vibration tests are compliant with the EN50155/IEC61373 vibration standards.3. Storage EnduranceStorage media, such as SSDs, CF cards, SD cards, Disk on Module, and Cfast, are composed of different electrical components. The main electrical components in these storage media, the NAND-flash memory and NAND-flash controller, impact the storage endurance and lifespan of the storage media.NAND-Flash Memory EnduranceNAND-flash memories have a limit on the number of times they can be programmed and erased (P/E). The P/E cycle as well as the erase count of a NAND-flash memory can be used to determine this limit. For example, an SLC (single-level cell) flash memory has a 60,000 P/E cycle, an MLC (multi-level cell) flash memory has a 3,000 P/E cycle, and TLC NAND flash memories have P/E cycle values up to 1,000. Each flash memory type has a different endurance level, which is why the storage lifespan is based on the flash memory type. Storage that uses SLC type flash memory could have the best endurance level compared with the MLC type storage. SLC storage usually comes with a 5-year OEM warranty (the actual warranty period depends on the original manufacturer). MLC storage only comes with a 1- to 3-year warranty. The major differences between SLC and MLC are: (a) The SLC NAND flash has a lifespan that is around 20 times that of an MLC, and (b) The price can differ by a factor of 4 to 5. The SLC type of storage is recommended for systems that are expected to have high reliability, and for applications that need to frequently write data to a storage medium.Terabytes Written (TBW)TBW is the unit used to evaluate SSD endurance. In actual applications, storage is used for routine operations and data access. Therefore the physical P/E cycle is not appropriate for describing thetotal rewritable data capacity result. For these reasons, Joint Electron Device Engineering Council (JEDEC) has defined a standard for SSD endurance evaluation called JESD218, which uses TBW to measure the endurance of the storage memory. By referring to this TBW value, users can easily estimate the storage specification and select a suitable storage for real-life use cases. For example, when routine operations need a maximum of 20 GB and the expected storage lifespan is 3 years, the total rewritable data demand would be 21.9 TBW (20 GB x 365 x 3). In this case, a storage that has more than 21.9 TBW will meet the requirement. We recommend selecting a storage media with a TBW that is greater than the calculated value.4. Declaration for Liability ExclusionThe specifications, warranty terms, and liability of items listed in this guide are the sole responsibility of the original manufacturers. Moxa does not take any responsibility in this regard. Please visit the manufacturers’ official websites for up-to-date product information before purchasing the components.5. Compatible ComponentsPeripheral components that have been tested and found suitable for use with the DA-685 series of computers are listed in this section. The following table lists the Test Codes and their descriptions:Test Code DescriptionA The component has passed the ambient temperature verification testB The component has passed the low temperature verification testC The component has passed the heat/humidity verification testD The component has passed the cyclic high-low temperature verification testE The component has not been tested, but is similar to another component that has been tested in terms of its material and design.F The component has passed the vibration verification testDRAMVendor MemorySize Moxa’s PN Vendor’s PN Interface Chip Brand Speed Test Codes DSL 1 GB N/A D2SM64162XH30ABIS DDR2 Micron 667 MHz B, C, D DSL 1 GB 1352110012030 D2SP64162XH30AAIS DDR2 ProMOS 667 MHz B, C, D DSL 2 GB 1352110022070 D2SP28082XH30ABIS DDR2 ProMOS 667 MHz B, C, D DSL 2 GB N/A D2SM28082XH30ABIS DDR2Micron 667 MHz B, C, D DSL 2 GB 1352110022080 D2SH28082XH30AB DDR2Hynix 667 MHz B, C, D DSL 4 GB 1352110042040 D2SM56082XH30AB DDR2Micron 667 MHz B, C, D InnoDisk 2 GB N/A M2SJ-2GPF2W05-B DDR2ProMOS 667 MHz B, C Transcend 1 GB N/A TS128MSQ64V8U DDR2Samsung 800 MHz E Transcend 2 GB N/A TS256MSQ64V8U DDR2Samsung 800 MHz A Transcend 2 GB N/A TS256MSQ64V6U-I DDR2Hynix 667 MHz B, C, D Unigen 2 GB N/A UG25T6400M8SU-8CP-000-00 DDR2Hynix 800 MHz B, C, DDOMVendor StorageSize Moxa’s PN Vendor’s PNFlashMemoryBrandFlashMemorySpecController Firmware Warranty WarrantyExclusionTestCodesInnoDisK 2 GB 1352020022080 DE4H-02GD31W1DB-A31 N/A SLC N/A N/A 5 years Endurance >60,000 B, C Memoright 1 GB N/A MRDEM2B001GB7P1IA0 Samsung SLC SM2232 K0407 5 years N/A E Memoright 2 GB N/A MRDEM2B002GB8P1IA0 Samsung SLC SM2232 K1124 5 years N/A B, C, D Memoright 8 GB N/A MRDEM2B008GN2P1IA0 Micron SLC SM2232 K0407 5 years N/A B, C, D Silicon Power 8 GB N/A SP008GBIFM44FOV10-MA Samsung SLC N/A N/A 3 years N/A B, C, D Transcend 1 GB N/A TS1GDOM44V-S Samsung SLC SM223 AC N/A 2 years N/A E Transcend 2 GB N/A TS2GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A E Transcend 4 GB N/A TS4GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A E Transcend 8 GB N/A TS8GPTM510-44V Samsung SLC SM2231 AD N/A 2 years N/A ACFVendorStorage SizeMoxa’s PNVendor’s PNFlash MemoryBrandFlash Memory SpecControllerFirmwareWarrantyWarranty ExclusionTest CodeApacer 4 GB N/A AP-CF004GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 8 GB N/A AP-CF008GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 8 GB N/A AP-CF008GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 16 GB N/A AP-CF016GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 E Apacer 16 GB N/A AP-CF016GL9FS-NR N/A MLCN/A N/A 2 years Endurance > 3,000 E Apacer 32 GB N/A AP-CF032GL9FS-NR N/A MLC N/A N/A 2 years Endurance > 3,000 A Apacer 32 GB N/A AP-CF032GLAFS-NR N/A MLC N/A N/A 2 years Endurance > 3,000A Transcend 128 MB N/A TS128MCF200I Samsung MLC SM2232AD N/A 2 years N/AE Transcend 256 MB N/A TS256MCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 512 MB N/A TS512MCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 1 GB N/A TS1GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 1 GB N/A TS1GCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 2 GB N/A TS2GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 2 GB N/A TS2GCF200I Samsung MLC SM2232AD N/A 2 years N/A E Transcend 4 GB N/A TS4GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 4 GB N/A TS4GCF200I Samsung MLCSM2232AD N/A 2 years N/A A Transcend 8 GB N/A TS8GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A E Transcend 8 GB N/A TS8GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 8 GB N/A TS8GCF200I Samsung MLCSM2232AD N/A 2 years N/A E Transcend 16 GB N/A TS16GCF1000 SanDisk/ Micron MLC SM2232ENAC N/A 2 years N/A E Transcend 16 GB N/A TS16GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A E Transcend 16 GB N/A TS16GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend 16 GB N/A TS16GCF200I Samsung MLCSM2232AD N/A 2 years N/A E Transcend 32 GB N/A TS32GCF1000 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A A Transcend 32 GB N/A TS32GCF400 SanDisk/ Micron MLC SM2236AC N/A 2 years N/A A Transcend 32 GB N/A TS32GCF133 SanDisk/ MicronMLC SM2232AD N/A 2 years N/A E Transcend32 GBN/ATS32GCF200ISamsungMLCSM2232ADN/A2 yearsN/AASSDVendorStorage SizeMoxa’s PNVendor’s PNFlash MemoryBrandFlash Memory SpecControllerFirmwareWarrantyWarranty ExclusionTest CodesApacer 64 GB N/A AP64GAS510SB N/A MLC N/A N/A 2 years Endurance > 3,000 A InnoDisk 32 GB N/A DGS25-32GD67SC1QCP Samsung MLC N/A N/A 2 years Endurance > 3,000 B, C, D InnoDisk 32 GB N/A DGS25-32GD81SC1QCP Toshiba MLC N/A N/A 2 yearsEndurance > 3,000B, C Memoright 32 GB N/A MRSAJ6C032GC125C00 Micron MLC JMF612 MRV1.1.5 3 years Endurance > 3,000 B, C, D Memoright 32 GB N/A MRSAJ9A032GTT25C00Toshiba MLC JMF667 MRV1.71b 3 years Endurance > 3,000B, C, D Transcend 16 GB N/A TS16GSSD500 Samsung SLC JM616 120820 2 years N/A E Transcend 32 GB N/A TS32GSSD500 Samsung SLC JM616 120820 2 years N/A E Transcend 64 GB N/A TS64GSSD320 SanDisk/ MicronMLC SF2281 N/A 2 years N/A E Transcend 64 GB N/A TS64GSSD500 Samsung SLC JM616 120820 2 years N/A A Transcend 128 GB N/A TS128GSSD320 SanDisk/ Micron MLC SF2281 N/A 2 years N/A E Transcend256 GBN/ATS256GSSD320SanDisk/ MicronMLCSF2281N/A2 yearsN/AAHDDVendor StorageSize Moxa’s PN Vendor’s PN Controller Firmware Test Code HGST 500 GB N/A HTS725050A7E630 / 0J38075 N/A N/A A HGST 1 TB N/A HCC541010A9E680 N/A N/A A HGST 1 TB N/A HTS541010A9E680 N/A N/A A HGST 1 TB N/A HTS721010A9E630 / 0J22423 N/A N/A A HGST 1 TB N/A HTS541010A9E650 N/A N/A A Samsung 2 TB N/A ST2000LM003 N/A N/A A WD 750 GB N/A WD7500BPKT N/A N/A A WD 1 TB N/A WD10JUCT N/A N/A A WD 1 TB N/A WD10JPVT N/A N/A A WD 1 TB N/A WD10SPCX N/A N/A A。

Omega OSXL685 和 OSXL689 高性能红外热温计用户指南说明书

Omega OSXL685 和 OSXL689 高性能红外热温计用户指南说明书

TM e-mail:**************For latest product manuals: User’s Guide OSXL685and OSXL689High PerformanceShop online at WITH BUILT-IN PATENTED LASER CIRCLE SIGHTINGServicing North America:U.S.A.:One Omega Drive, Box 4047ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec) H7L 5A1, CanadaTel: (514) 856-6928FAX: (514) 856-6886e-mail:*************For immediate technical or application assistance:U.S.A. and Canada:Sales Service: 1-800-826-6342/1-800-TC-OMEGA ®Customer Service: 1-800-622-2378/1-800-622-BEST ®Engineering Service: 1-800-872-9436/1-800-USA-WHEN ®Mexico:En Espa n ˜ol: (001) 203-359-7803FAX: (001) 203-359-7807e-mail:*******************************.mx Servicing Europe:Czech Republic:Frystatska 184, 733 01 Karviná, Czech Republic Tel: +420 (0)59 6311899FAX: +420 (0)59 6311114Toll Free: 0800-1-66342e-mail:*****************Germany AustriaDaimlerstrasse 26, D-75392 Deckenpfronn, GermanyTel:+ 49 (0)7056 9398-0FAX: +49 (0)7056 9398-29TollFreeinGermany************e-mail:*************United Kingdom:One Omega Drive, River Bend Technology Centre ISO 9002Certified Northbank, Irlam, ManchesterM44 5BD United Kingdom Tel: +44 (0)161 777 6611FAX: +44 (0)161 777 6622Toll Free in United Kingdom: 0800-488-488e-mail:**************.ukOMEGAnet ®On-Line Service Internet e-mail ***********************It is the policy of OMEGA Engineering, Inc. to comply with allworldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to everyappropriate device upon certification.The information contained in this document is believed to becorrect, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be u sed for, human applications.21-3 Warnings and Cautions 1511466678131314144-4 Advanced Functions 8.Emissivity Table 7.6.5.PC Interface (OSXL689)Patented Laser Circle SightingTemperature Data StorageHigh & Low Audible Alarms50:1 Field of View - OSXL68930:1 Field of View - OSXL685K Type Thermocouple Input - OSXL689USB PC Interface - OSXL689temperature, point the unit at the object, pull and hold the measuring trigger until the temperature is read. Make sure the target area is larger than the unit’s Field of View. For large target objects make sure you are within target distance.1-3 Warnings and CautionsCAUTIONYou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below:• Use of controls or adjustments or performance of procedures other than those specified here may result in hazardous radiation exposure.• Do not look at the laser beam coming out of the lens or view directly with optical instruments - eye damage can result.• Use extreme caution when operating the lasersighting.• Never point the laser beam at a person.• Do not attempt to open the thermometer. There are no user serviceable parts.• Keep out of the reach of all children.Refer to the inside back cover for product warning label.Read the following instruction manual carefully before attempting to operate the thermometer. Only qualified personnel should perform repairs which are not covered in this manual.-50 to 1000°C (-58 to 1832°F) OSXL685OSXL689 From -50 to -20°C (-58 to -4°F) From -20 to 100°C (-4 to 212°F) 100 to -1000°C (212 to 1832°F)YES - Laser CircleData Storage AlarmsK Type TC USB Port 10 PointsHigh and Low0 to 50°C, 10 to 90% RH Adjustable 0.1 to 1.08 to 14 µm30:150:1–––-200/1300°CTC Input Accuracy–––0.5% Rdg+1°C–––YESWavelength (Color):Operating Distance: Up to 10 ft.Max. Output Optical <1mW at 75°F ambient Power: temperature,Class II Laser ProductEuropean Classification: Class 2, EN60825-1FDA Classification: Complies with 21 CFR Chapter 1, Subchapter JBeam Diameter: 5 mmBeam Divergence: <2mradLaser Configuration: Dot and CirclePower Switch: Slide switch, ON-OFF Power Indicator: Laser icon on displayPower: Supplied by the thermometer Identification Label: Located on the right side of the thermometerWarning and Located on the left side of the Certification Label: thermometer630 to 670 nanometers (red)3.Specifications con’ser SightingLaser ApertureOptical Lens Laser Circle SightingMeasuring TriggerThermocouple Input (OSXL689)Battery Compartment Display Screen ID Label To measure a temperature, point the unit at the target, pull the trigger and hold. Make sure the target area is within the field of view of the instrument. The laser circle sighting is used to indicate the perimeter of the instrument’s field of view.Laser Warning &Certification Label and Field of View LabelLaser Warning &Certification Label and Field of View LabelUSB Port (OSXL689)4-3 °C/°F, Laser Switch and BatteryReplacementThere are two slide switches in front of the battery compartment. One is for °F/°C display and the other is for laser sighting. To change the battery, directly place the battery in the battery compartment.4-4 Advanced Functions4-4-1 AUTO Mode-ContinuousOperationFrom the SCAN mode (Trigger is pulled), you canlock the trigger electronically and measuretemperature continuously (AUTO mode) by pressing the LOCK key. The AUTO icon will appear on thedisplay. Pressing the LOCK key again will disablethe AUTO mode. AUTO icon will disappear from the display. If the trigger is pulled, the unit stays in theSCAN mode. If the trigger is released, the unit will go to HOLD mode and will shut itself off after about 6seconds.The following table shows an overall functional flowchart of the thermometer:Mode Press Mode Key Press Up Key Press Down Key SCAN SCAN AUTO ---- ----AUTO AUTO DATA Record ---- ----DATA DATA RECORD DATA + Memory Location - Memory Location RECORD RECALL (Press M key to record)(Flashing) (Flashing) DATA DATA RECALL Max Temp + Memory Location - Memory Location RECALL Display Data Memory Display Data Memory Max Temp Max Temp Min Temp + Memory Location - Memory Location(Flashing) (Flashing)Min Temp Min Temp Avg Temp + Memory Location - Memory Location(Flashing) (Flashing)Avg Temp Avg Temp ∆T + Memory Location - Memory Location(Flashing) (Flashing)∆T ∆T TC + Memory Location - Memory Location(Flashing) (Flashing) TC TC Emissivity +Memory Location –Memory Location (OSXL689) (Flashing) (Flashing)Emissivity Emissivity High Alarm + Emissivity – Emissivity HAL High Alarm Low Alarm + Alarm Set Point – Alarm Set Point LAL Low Alarm SCAN/HOLD + Alarm Set Point – Alarm Set Point4-4-2 Max, Min, Avg, ∆T Temperature You can review the Maximum, Minimum, Average,and differential (Max - Min) temperatures on thedisplay by pressing the Mode key. If the trigger ispulled at the same time, the display will show SCAN icon and all the values are in real time. If the trigger is released, the display will show the HOLD icon and all the values are the last readings before the trigger is released.4-4-3 Temperature Data Storage& Recall - DATA ModeYou can store up to 10 temperature data points(Memory Location 1 thru A). When you are in DATA RECORD mode, set the memory location using the Up or Down arrow keys, then press the M key. Theunit will store the temperature data in the currentmemory location.You can review (recall) the stored data by going tothe DATA RECALL mode using the Mode key andpressing the Up/Down keys. You can then reviewmemory locations 1 thru A.NOTEThe unit stores all temperature data, emissivityvalue, high and low alarm set points in thenon-volatile memory. Changing the battery will notaffect these values.* In Data Record Mode, pressing the M key will record the data in the corresponding memory location.* In Data Recall Mode, you can delete all recorded data by going to DATA o memory location and pressing the Mkey.* Pulling the Trigger or pressing any of the keys will turn on LCD backlight.NOTEA 6" Surface Probe (Model SPHT-K-6) is includedwith Model OSXL689.5. PC Interface (OSXL689) This infrared thermometer has a USB PC interface. It comes with a USB cable and CD software. Install the PC software before connecting the thermometer to the PC USB port. The minimum PC system requirements are:• Windows XP• 64 MB of RAM• 5 MB of Disk spaceAfter completing the software installation, run the program and connect the thermometer to the PC using the USB port. Turn on the thermometer by pulling the trigger. After a few seconds the PC recognizes the thermometer connection and a USB icon appears on the thermometer’s display. The PC now shows the same target temperature as what is displayed on the thermometer. The thermometer's trigger is locked by the USB connections so there is no need to continue pulling the trigger. The following picture is what you see on the PC.The target temperature is displayed in either °F or °C. Then the Date (yy-mm-dd) and Time(Hour:Minute:Second) are displayed. You can switch between °F and °C temperature display by clicking on the unit of measurement (°F or °C).Infrared ThermometerTarget Temperature125.6°F°F°C2006-5-02 9:50:26Record IntervalHour Minute SecondRecordExit Stop5-1 Recording Temperature Data to a File Set your recording interval in terms of Hours, Minutes, Seconds. This is the time interval between every temperature data point. Than check on Record key. A selection file text box opens. Enter a text file name, and click on Save key to start the recording process. Now temperature data are being saved in the text file at the specified recording interval. You can determine the recording process by clicking the Stop key. Now you can go back and review the data text file.You can exit the program by clicking the Exit key.OSXL685OSXL68919@500 20@100064@20002.5@800.8@400.7@20bring the thermometer closer to the target to ensure that the target area is larger than the optical field of view.D:S = 50:16-2 Emissivity7. MaintenancePATENT NOTICE:U.S. PA T. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678;5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1;6,377,400 B1; 6,540,398 B2; 6,614,830 B1; 6,633,434 B2;6,659,639; 6,901,089 B1 / Canada 2,114,806; 2,317,734 / France 2 756 920; 2 767 921; 2 773 213; 2 773 214 /Germany G 94 22 197.9; G 94 22 203.7 / Holland1007752; / U.K. Registered 2,237,493; 2,320,324;9726133.3 / EPO 0 644,408 B2; EPO 1085 307 A1.Other U.S. and Foreign Patents Pending.8. Emissivity TableWARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANT Y does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. T his WARRANT Y is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specifica-tion; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the compamy will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED W ARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANT Y/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RET URNING ANY PRODUCT(S) T O OMEGA, PURCHASER MUST OBT AIN AN AUT HORIZED RET URN (AR) NUMBER FROM OMEGA’S CUST OMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). T he assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number underwhich the product wasPURCHASED,2. Model and serial number of theproduct under warranty, and3. Repair instructions and/or specificproblems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair,2. Model and serial number of the product, and3. Repair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved. This docu-ment may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without theWhere Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at TEMPERATUREⅪߜThermocouple, RTD & Thermistor Probes,Connectors, Panels & AssembliesⅪߜWire: Thermocouple, RTD & ThermistorⅪߜCalibrators & Ice Point ReferencesⅪߜRecorders, Controllers & Process MonitorsⅪߜInfrared PyrometersPRESSURE, STRAIN AND FORCEⅪߜTransducers & Strain GagesⅪߜLoad Cells & Pressure GagesⅪߜDisplacement TransducersⅪߜInstrumentation & AccessoriesFLOW/LEVELⅪߜRotameters, Gas Mass Flowmeters & Flow ComputersⅪߜAir Velocity IndicatorsⅪߜTurbine/Paddlewheel SystemsⅪߜTotalizers & Batch ControllerspH/CONDUCTIVITYⅪߜpH Electrodes, Testers & AccessoriesⅪߜBenchtop/Laboratory MetersⅪߜControllers, Calibrators, Simulators & PumpsⅪߜIndustrial pH & Conductivity EquipmentDATA ACQUISITIONⅪߜData Acquisition & Engineering SoftwareⅪߜCommunications-Based Acquisition SystemsⅪߜPlug-in Cards for Apple, IBM & CompatiblesⅪߜDatalogging SystemsⅪߜRecorders, Printers & PlottersHEATERSⅪߜHeating CableⅪߜCartridge & Strip HeatersⅪߜImmersion & Band HeatersⅪߜFlexible HeatersⅪߜLaboratory HeatersENVIRONMENTALMONITORING AND CONTROLⅪߜMetering & Control InstrumentationⅪߜRefractometersⅪߜPumps & TubingⅪߜAir, Soil & Water MonitorsⅪߜIndustrial Water & Wastewater TreatmentⅪߜpH, Conductivity & Dissolved Oxygen Instruments。

EVDO Rev.A USB Modem CDU-685A 使用说明书

EVDO Rev.A USB Modem CDU-685A 使用说明书

Get Started EVDO Rev. A USB ModemCDU-685ATable of ContentsHow to Use This GuideSection 1: Introducing the EVDO Rev.A USB Modem1A. Introducing the Cox EVDO Rev.A-System Requirements-Package Contents-Care and MaintenanceSection 2: Installing and Using the USB Modem2A. Installing the Software and Drivers2B. Using Your USB Modem-Activating Your USB Modem-Viewing the User Guide-Removing the USB Modem-TroubleshootingSection 3: Technical Specifications, Regulatory and Safety Information, and Warranty 3A. Technical Specifications-Radio Frequency and Electrical Specifications-RF Frequencies-Software Specifications-Environmental Specifications-Mechanical Specifications3B. Regulatory Information-Caution-WARNING (EMI) – United States FCC Information-Body worn operation3C. Important Safety Information-Important Notice-Safety and Hazards3D. Warranty-Manufacturer's Limited One-Year WarrantyHow to Use This GuideThe advantages of Cox are as clear as each wireless connection you make. With Cox service, we give you what you really want from a wireless service provider—clear connections, easy-to-understand service plans, and self-servicing options for managing your account. All this is designed to make your life easier and worry-free.We know you’re eager to start using your USB Modem CDU-685A right away, and the sections of this guide are designed to help you do just that.The first section gives an overview of the USB Modem CDU-685A package contents.The second section guides you through the steps required to install your USB Modem CDU-685A and the Windows drivers and software, describes how to start the software once it is installed, and explains how to use the Y-extension cable with your device.The third section lists the technical specifications, regulatory and important safety information, and warranty information for your USB Modem CDU-685A.Getting More Information About Your Device and ServiceThis guide describes how to install and start the software. To learn how to use all the features of your USB Modem CDU-685A and software, consult the user guide or online help.Section 1 : Introducing the EVDO Rev.A USBModemSection 1A : Introducing the Cox EVDO Rev.A USB ModemThis section introduces your USB Modem CDU-685A, and describes what is included with your device.The USB Modem CDU-685A is a wireless USB modem.Using this device, and subject to network availability, you can:•Easily activate your account•Connect to the Internet and to VPN and corporate networks•Send and receive large email messages•Download media content (music, videos and real-time and streaming media)•Play games onlineSystem RequirementsThis Cox Mobile Broadband USB modem is supported on:•Windows Vista.•Windows XP with Service Pack 2 or later.•Windows 2000 with Service Pack 4 or later.•Windows 7To install and run the USB modem and the accompanying Cox Connection Manager SM software, you will need:a free USB slot.• a minimum of 256 MB of memory using Windows 2000 and Windows XP.• a minimum of 1 GB of memory using Windows Vista.• a minimum of 70 MB of free space on your hard drive.• a minimum processor speed of 300 MHz for Windows 2000 and Windows XP.• a minimum processor speed of 800 MHz for Windows Vista.*Note : You can connect your device to any computer (desktop or laptop) with a USB slot.Package ContentsUSB Modem CDU-685A package contains the following components:•Cox EVDO Rev.A USB Modem CDU-685A•Get Started guide•Installation CDCare and MaintenanceAs with any electronic device, USB modem must be handled with care to ensure reliable operation. Follow these guidelines in using and storing the USB modem:•The USB modem should fit easily into an available USB slot. Forcing the device into a slot may damage the connector pins.•Protect your USB modem from excessive moisture and heat, and from prolonged exposure to the sun.•When it is not connected to your computer, store your USB modem in the pouch that came with the modem to avoid dust.•Remove your USB modem before storing or transporting your computer.•When inserting or removing your USB modem, always grip from the sides rather than the end, as this prevents damage to the USB modem.•Do not use your USB modem while driving a vehicle, as it may distract you from properly operating the vehicle.•Dispose of your USB modem in accordance with EPA guidelines. For more information, visit /epawaste/partnerships/plugin/cellphone/index.htm.Section 2 : Installing and Using the USB ModemSection 2A : Installing the SoftwareInstalling the Software and Drivers1.Insert the installation CD into your CD-ROM drive. The CD should launch automatically. Click Setup tocontinue. (If autoplay is disabled, navigate to your CD-ROM drive in Explorer and click setup.exe.)2.In the “Welcome to the InstallShield Wizard” installation window, click Next.3.Read the License Agreement and select “I accept the terms in the License Agreement”to agree to theterms. Click Next.4.Select a skin (“New”or “Classic”) and click Next.5. In the “Destination Folder” window, click Next to accept the default installation folder (recommended); or click Change, specify a different installation folder, and then click Next to continue.6. Click Install to begin installation.7. When the “InstallShield Wizard Completed” window appears, click Finish.8. If a message that you must restart your computer is displayed, click Yes to restart your computer. Wait until your computer restarts.9. Proceed to Activating Your USB Modem.Section 2B : Using Your USB ModemActivating Your USB ModemIf your USB modem has not been preactivated or you have not activated it at the time of purchase, you must activate your account and configure the USB modem to use your account. (Normally, your device will automatically complete the activation process the first time you use it.)1.Gripping both sides of the USB modem, insert it into your computer’s USB port. Windows detectsthe USB modem and installs the drivers for it. This may take a few minutes. Once completed, thesystem tray may display “Your devices are ready to use” or “Your new hardware is installed andready to use.”unch Connection Manager by double-clicking the program’s icon.3.Hands Free activation starts automatically and will be displayed on the Cox. After the activationsuccessfully completes, it will automatically connect and welcome you to the Cox Network.4.If activation was not successful, a message window is displayed. For instructions on activating yourUSB modem, see the user guide (see “Viewing the User Guide”). Use the spaces below to writedown important information related to the activation process and your account.ESN/MEID______________________________________Activation code__________________________________Cox Phone number____________________________MSID__________________________________________Account password_______________________________Cox User Name________________________________Viewing the User GuideThe user guide provides detailed information on the Cox Connection Manager software.On your computer, select Start > All Programs > Cox > Connection Manager > Users Guide.On your computer, select Start > My Computer. Right click on CD/DVD RW Drive and select EXPLORE > UserGuide.Removing the USB Modem1.Disconnect from the Cox Connection Manager software if it is running.2.Remove the USB modem from your computer’s USB slot by gripping both sides of the USB modemand pulling straight out.Troubleshooting1. For a more complete listing of errors and possible solutions, please see the user guide or online Help. You may also call Cox Customer Service.2. Ensure that the Connection Manager software has been successfully installed on your computer.3. Ensure that your USB modem has been activated.4. Ensure that the USB modem is fully plugged into the USB slot.5. Ensure that the LED light is on; otherwise connect and then reconnect the USB modem.Section 3 :TechnicalSpecifications, Regulatory and SafetyInformation, and WarrantySection 3A : Technical SpecificationsRadio Frequency and Electrical SpecificationsFrequencies CDMA 800/AWS/1900 MHz Interface Type High-Speed USB 2.0 compliant Common air interface CDMAAntenna Diversity Support Receive DiversityDC input operating voltage +5VDC from USB host port Maximum current @+5VDC Under 500mARF FrequenciesBC0TX frequency: 824MHz – 849MHzRX frequency: 869MHz – 894MHzBC1TX frequency: 1850MHz – 1910MHzRX frequency: 1930MHz – 1990MHzAWSTX frequency: 1710MHz – 1755MHzRX frequency: 2110MHz – 2155MHzSoftware SpecificationsOS Support Windows® 2000, XP, Vista and Windows 7Environmental SpecificationsOperating conditions -20°C ~ +55°C , 85%(at 50(°C)), relative humidity (non-condensing) Storage Temperature -35°C ~ +75°CHumidity 95%, non-condensingMechanical SpecificationsDimensions 32.1mm * 72.1mm * 11.9mmWeight Approx. 23gForm Factor USB Series “A” Type plugHousing Material CASE – PCSection 3B : Regulatory InformationThis device is compliant with Parts 15, 22, 24, and 27 of the FCC Rules. Operation of this device is subject to the following two conditions:1. This device may cause harmful interference.2. This device must accept any interference received, including interference that may cause undesirable operation. FCC ID: TARCDU-685ACAUTIONUnauthorized modifications or changes not expressly approved by manufacturer could void compliance with regulatory rules and thereby your authority to use this equipment.WARNING (EMI) – United States FCC InformationThis equipment has been tested and found to comply with the limits pursuant to Parts 15, 22, 24, and 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in an appropriate installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.Body worn operationSAR compliance has been established in the laptop computer(s) with Horizontal and Vertical USB slot configurations, and can be used in laptop computers with substantially similar physical dimensions, construction, and electrical and RF characteristics.Section 3C: Important Safety InformationImportant NoticeBecause of the nature of wireless communications, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors), or be totally lost. Although significant delays or losses of data are rare when wireless devices such as the Cox EVDO Rev.A USB Modem CDU-685A are used in a normal manner with a well-constructed network, they should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party, including but not limited to personal injury, death, or loss of property. Manufacturer accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the Cox EVDO Rev.A USBModem CDU-685A, or for failure of Cox EVDO Rev.A USB Modem CDU-685A to transmit or receive such data.Safety and HazardsDo not operate modem in areas where blasting is in progress, where explosive atmospheres may be present, near medical equipment, life support equipment, or any equipment which may be susceptible to any form of radio interference. In such areas, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. It can transmit signals that could interfere with this equipment. Do not operate the Cox EVDO Rev.A USB Modem CDU-685A in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the Cox EVDO Rev.A USB Modem CDU-685A must be removed from your computer. When operating, it can transmit signals that could interfere with various onboard systems. The driver or operator of any vehicle should not operate the Cox EVDO Rev.A USB Modem CDU-685A while in control of a vehicle. Doing so will detract from the driver or operator’s control and operation of that vehicle. In some jurisdictions, operating such communication devices while in control of a vehicle is an offense.Section 3D : WarrantyManufacturer’s Limited One-Year WarrantyThe company warrants to original retail purchaser of this device, that should product during normal consumer usage conditions, be proven defective in material or any part thereof, during normal consumer usage conditions, be defective in material or workmanship that results in product failure within the first twelve (12) month period from the date of purchase, such defects will be repaired or replaced (with new or refurbished) product at the Company’s discretion, without charge for parts and labor directly related to the defect(s). This warranty extends to consumers who purchase the product in the United States or Canada and it’s not transferable or assignable. This warranty does not apply to:(a) Product subject to abnormal use or conditions, accident, mishandling, neglect, unauthorized alteration, misuse, improper installation or repair or improper storage;(b) Products whose mechanical serial number or electronic serial number has been removed, altered, or defaced;(c) Damage from exposure to moisture, humidity, excessive temperature or extreme environment conditions;(d) Damage resulting from connection to, or use of any accessory or other product not approved or authorized by the company;(e) Defects in appearance, cosmetic, decorative or structural items such as framing and non-operative parts;(f) Product damaged from external causes such as fire, flooding, dirt, sand, weather conditions, battery leakage, blown fuse, theft or improper usage of any electrical source.The Company disclaims liability for removal or reinstallation of the product, for geographic coverage, for inadequate signal reception by the antenna or for communications range or operation of the cellular system as a whole.When sending your wireless device to authorized distributors for repair or service, please note that any personal data or software stored on the device may be inadvertently erased or altered. Therefore, we strongly recommend you make a back up copy of all data and software contained on your device before submitting it for repair or service. This includes all contact lists, downloads (i.e. third-party software applications, games and graphics) and any other data added to your device. Manufacturer is not responsible for and does not guarantee restoration of any third-party software, personal information or memory data contained in, stored on, or integrated with any wireless device, whether under warranty or not, returned to manufacturer’s authorized distributors for repair or service. To obtain repairs or replacement within the terms of this Warranty, the product should be delivered with proof of Warranty coverage (e.g. dated bill of sale), the consumer’s return address, and daytime phone number and/or fax number and complete description of the problem, transportation prepaid, to the Company at the address shown below or to the place of purchase for repair or replacement processing.The extent of the company’s liability under this warranty is limited to the repair or replacement provided above and, in no event, shall the company’s liability exceed the purchase price paid by purchaser for the product.Any implied warranties, including any implied warranty of merchant ability or fitness for a particular purpose, shall be limited to the duration of this written warranty. Any action for breach of any warranty must be brought within a period of 18 months from date of original purchase in no case shall the company be liable for a special consequential or incidental damages for breach of this or any other warranty, express or implied, whatsoever. The company shall not be liable for the delay in pending service under this warranty or loss of use during the time the product is being repaired or replaced.No person or representative is authorized to assume for the Company any liability other than expressed herein in connection with the sale of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts on the exclusion or limitation of incidental or consequential damage so the above limitation or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to province.TrademarksCox and the logo are trademarks of Cox. Other marks are the property of their respective owners. Windows® is a registered trademark of Microsoft Corporation. Copyright ©2009 Cox. Cox and the logo are trademarks of Cox. Other marks are the property of their respective owners.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

ADEMCO 685 数字通讯接收机
安装使用手册
目录:
1. 安装程序 1
2. 使用介绍(图5) 5
3. 通讯格式之定义7
4. 附件:9
1. 安装程序
1.1. 旋开685 上盖的四颗镙丝
1.2. 由於运输途中,可能使分别在板槽J1,J3及J5的显示驱动器卡,记忆体卡
及中央处理器卡与板槽接触不良,因此必须使用各电路板两端白色的启
出杆启出各电路板,再重新插入以确保各电路板与板槽接触正常.(图1)
1.3. 检查各接线插头接触良好
(如将来685 需要移动,也需要重覆此步骤1至3)
1.4. 记忆体卡的安装(图2)
1.4.1.将写有"685C" 的691 PROM芯片依图2插入记忆体卡之691 晶片
槽内。

注意红色三角形在左下角方向
1.4.
2.依图2和你的周边设备设置跨接线位置
1.5. 电话线卡(图3)
1.5.1.将电话线卡由板槽J6 起插入
1.5.
2.连接电话接头
1.5.3.调整组别号码旋钮开关
(如电话线卡#1调为1,电话线卡#2调为2.....)此号码会显示在前板数字发光
二极管GRP.NO. 处
1.6. 685接线(图4)
1.6.1.连接电话线
1.6.
2.连接并行式打印机(J105). 开启打印机电源
(某些打印机其PIN9 必须和PIN16 连接起来才能正常操作)
1.6.3.连接外接警号(J104为常闭开关输出,开关最大额定值为12 伏特直流2
安培)
(需外接电源12VDC)
1.7. 检查以上各步骤,证实无误後连接电源(220VAC,50Hz) 1.8. 这时685被启动,各指示灯闪亮,打印机会打印出一段文字
1.9. 接入後备电池(J106,J107为并联)
后面
前面
图 1 685机内俯视图
图3 电话线卡
电源模块
检测串行式打印机(20脚为准备好线):跨线2和3 检测串行式打印机(21脚为准备好线):跨线1和2 不检测串行式打印机:出厂时设置(跨线4和5)
图2 记忆体卡设置
2. 使用介绍(图5)
2.1. 前板按钮功能
2.1.1.AUTO/MANUAL 自动/手动开关
a. 在AUTO 自动位置,如周边设备,如打印机,操作正常,则所有信息将自动
输出.
b. 在MANUAL 手动位置,任何信息将被储存在685记忆体中,直至操作员
按下DISPLAY NEXT MESSAGE 显示下一信息键
* 在AUTO 自动位置时,如685检测到周边设备故障,将自动切换至
MANUAL手动模式. 685自动方式还与打印机、电脑选用设置及检测
开关设置有关。

参看附件。

2.1.2.VALID/ALL 有效/所有开关
a. 在VALID 有效位置,685只显示校验无误的信息
b. 在ALL 所有位置,685将显示所有信息
2.1.
3.DISPLAY NEXT MESSAGE 显示下一信息键
见AUTO/MANUAL 自动/手动开关说明。

2.1.4.BATTERY TEST 电池测试键
此键为测试685附接之电池电压之用.测试时,685将停止使用交流电源
五分钟.而只单独使用後备电池电力.
a. 启动电池测试功能
按下电池测试键直至左方LED发光二极管闪动为止.(约两秒钟)
b. 取消电池测试
按下电池测试键直至左方LED发光二极管熄灭为止.(约两秒钟)
2.1.5.SYSTEM TEST 系统测试键
a.按下系统测试键,所有前板LED 发光二极管皆发亮,以为检验发光二极管
之用
b.松开系统测试键,SYSTEM TEST 信息将由前板显示,并传送至各周边设

c.10秒钟内,所有电话线卡将被测试
2.1.6.SILENCE ALERT 停止响号键
按下此键以停止685提醒响号
2.2. 前板信息LED 发光二极管
2.2.1.用户来电信息(MESSAGE TYPE)
劫盗HOLD-UP 低电池电压LOW BATT
火警FIRE ALARM 撤防OPENING
窃盗BURG ALARM 布防CLOSING
复位RESTORE 测试TEST
2.2.2.来电状态(MESSAGE STATUE)
VALID 亮著时,经校验为有效信息
WAITING 亮著时,有信息正待处理.可按显示下一信息(DISPLAY NEXT
MESSAGE)键处理下一信息
ACTIVE 亮著时,代表正接收来电
2.2.
3.685系统故障(SYSTEM FAILURE)
LOW BAT 後备电池电压低於11.2伏特
A.C. 已经五秒钟无交流电供应
PRINTER 打印机故障或连接有问题
COMPUTER 电脑故障或连接有问题
LINE FAULT 电话线故障,其正下方之数字发光二极管将显示电话线
卡号码
2.3. 前板数字段码发光二极管显示
RCVR.NO. 接收机号码
GRP.NO. 电话组别(线卡)号码
ACCOUNT NUMBER 用户号码
CHANNEL NUMBER 来电信息
STATUS CHANNEL 来电信息
TIME 时间
DATE 日期
FAULTED LINE 故障之电话线卡号码
2.4. 前板下拉门内各键
2.4.1.DIP 双列直插开关
AUTO-MA 工厂测试使用
CRLF-CR (Carriage Return, Line Feed/Carriage Return Only)
打印机回车及回行
PRN-OFF PRN - 连接打印机
OFF - 不接打印机
1S-2S 1秒或2秒握手信号延迟
12H-24H 时间以12小时制或24小时制显示
1RG-2RG 振铃1次或2次接入来电
OFF-COM OFF - 不接电脑
COM - 连接电脑
2.4.2.其他按键及开关
RECEIVER NUMBER 此旋钮在调整接收机号码,显示在前板发光二
极管RCVR.NO. 处.
SYSTEM RESET 按下此钮後系统将重新设定.
SEND KISSOFF 工厂测试用.
CHANNEL ADVANCE 工厂测试用.
DATE SET/OFF/TIME SET 日期/时间设定用.
* 设定日期时将开关移至DATE SET 处,按MONTH 钮设定月份,按DAY 钮设定日子. 设定时间时将开关移至TIME SET 处.按HOUR
钮设定小时,按MINUTE 钮设定分钟. 设定完毕後将开关移至OFF 处.
MONTH/HOUR 设定月份或小时
DAY/MINUTE 设定日子或分钟
* MONTH/HOUR 及DAY/MINUTE 需一直按著,直至显示正确日期/时

3. 通讯格式之定义
3.1. ADEMCO 3+1或4+1
3.1.1.格式
CCC E - 3+1
CCCC E - 4+1
C:用户号码. E:事件码
3.2. 事件码定义
1 - 火警FIRE ALARM
2 - 劫盗HOLD-UP
3 - 窃盗BURG ALARM
4 - 撤防OPENING
5 - 布防CLOSING
6 - 无交流AC POWER ALARM
7 - 低电池电压 LOW BATT ALARM
8 - 复位RESTORE
9 - 测试TEST
3.3. ADEMCO 3+2或4+2
3.3.1.格式
CCC E Z - 3+2
CCCC E Z - 4+2
C:用户号码. E:事件码. Z:防区/使用者.
3.3.2.事件码定义
与3+1/4+1 相同
3.4. ADEMCO CONTACT ID
3.4.1.格式
CCCC QEEE GG RZZZ
C:用户号码, Q:事件识别, EEE:事件码
G:子系统, R:防区/使用者Z:防区/使用者号码
4. 附件:
电话噪音滤波器
ADEMCO 685附加一个8路的电话噪音滤波器,可以滤除电话线路中的噪音与电流冲击,以保护685,同时还可以起避雷作用。

下面介绍其连接使用方法:
1。

断开交直流电源。

2。

连接滤波器至685。

①滤波器有8束连接线引出接至685,每束线内有三根线:
红色表示电话线(+)极;黑色表示电话线(-)极;分别与685电话线输入接线柱上的极性相对连接。

另外一条色线表示不同的电话线序号,如下表所示:
这些色线全部都接在685外壳的接地螺丝上。

②把685外壳可靠接地,把滤波器的9、10脚接地。

注意:此时电话线接线柱第17、18(即接地端)应断开。

685自动与手动转换及其设置表
685自动状态时,AUTO/MANUAL的黄灯熄灭,此时所有报警信息自动输出到电脑、打印机等外设。

685处于手动状态时,AUTO/MANUAL黄灯闪烁,此时所有报警信号都自动存储起来,每条电话线可以存储14条信号,当信号数超过14条时,685将不接受报警信号,请注意排除故障,恢复自动状态。

说明:“正常”表示检测外设工作正常:如电脑的RS232口的20脚电平正常;打印机在线等。

“故障”表示检测到外设工作不正常,此时685右边对应黄灯闪烁。

“- ”表示该项状态不影响。

相关文档
最新文档