七层北京某办公楼毕业设计计算书
本科毕业论文---办公综合楼建筑、结构设计土木工程计算书
本科毕业论⽂---办公综合楼建筑、结构设计⼟⽊⼯程计算书题⽬:柳州市某办公综合楼建筑、结构设计专业:⼟⽊⼯程专业班级:⼟⽊xxx姓名:xxx学号:xxxxxxxx指导教师:xxx职称:xxx⼆〇⼀四年五⽉⼗⼋⽇摘要本⼯程为某综合楼⼯程,总楼层为地上5层,局部6层。
总建筑⾯积3170.89m2。
本⼯程结构设计采⽤多层钢筋混凝⼟框架结构,基本步骤为:结构计算简图的确定;板的设计、楼梯的设计、荷载计算;内⼒分析;内⼒组合;梁、柱截⾯配筋、基础的设计以及结构施⼯图的绘制等。
其中,内⼒计算分⽆地震内⼒组合与有地震内⼒组合。
⽆地震内⼒计算考虑以下三种荷载作⽤,即恒荷载、活荷载、风荷载,恒载内⼒计算采⽤⼆次分配法;有地震内⼒计算考虑重⼒荷载代表值和地震荷载。
柱、板的设计采⽤弹性理论;梁的设计采⽤塑性理论;风荷载、地震荷载内⼒计算均采⽤D值法;楼梯选⽤板式楼梯;基础选⽤柱下独⽴基础。
关键词:钢筋混凝⼟;框架结构;结构设计AbstractThis project is a comprehensive building,including 5 floors of earth amd 6layers of local. The total construction area is 3170.89m2.The engineering structure is designed by multi-layer structure of reinforced concrete frame construction. The basic steps are:the determination of the structure calculation diagram; design of board, design of staircase , load calculation; internal force analysis; internal force combinations; beams, columns section of reinforcement, foundation design and structural construction drawings and other drawings. Among in them, the internal force calculation is divided into non- combination of internal forces and earthquake seismic combination of internal forces. Non-internal force calculation takes into account the following three seismic loads:dead loads, live loads, wind loads.And the calculation of constant load force use the secondary distribution method. Seismic internal force calculation takes into account the representative value of gravity load and seismic loads.The design of column, board uses the theory of elasticity and beams design uses plastic theory. About the wind loads, seismic loads are used to calculate the internal forces by D-valued method.Stairs selects plate stairs;and the foundation selectes independent foundation under column.Keywords Reinforced Concrete; Frame Construction; Structural Design⽬录摘要..................................................................................................................................... I ABSTRACT ........................................................................................................................... I I ⽬录.................................................................................................................................. III 第⼀部分建筑设计/结构设计 (1)1 ⼯程概况和设计资料 (1)1.1⼯程概况 (1)1.2相关设计资料 (1)2.2结构体系 (2)2.3梁、板、柱截⾯尺⼨的估算 (2)2.3.1 梁截⾯尺⼨的估算 (2)2.3.2 板截⾯尺⼨的估算 (3)2.3.3 框架柱截⾯尺⼨的估算 (4)3 三层现浇楼板 (6)3.1楼板平⾯图 (6)3.2板的荷载计算 (6)3.2.1 板的恒荷载计算 (6)3.2.2 可变荷载标准值 (7)3.2.3 楼⾯荷载设计值计算 (7)3.2.4 板的荷载设计值 (8)3.3板的弯矩计算和配筋 (9)3.3.1 计算跨度 (9)3.3.2 弯矩计算及配筋 (9)4 三层现浇楼梯设计 (17)4.1设计资料 (17)4.2.1 尺⼨设计 (17)4.2.2 荷载计算 (18)4.2.3 截⾯设计 (18)4.3平台板设计 (19)4.3.1 荷载计算 (19)4.3.2 截⾯计算 (19)4.4平台梁设计 (20)4.4.1 荷载计算 (20)4.4.2 截⾯计算 (20)4.5梯柱设计 (22)5 框架计算 (23)5.1确定框架的计算简图及梁柱线刚度 (23) 5.1.1 确定框架的计算简图 (23)5.1.2 框架梁柱线刚度计算 (24)5.2竖向荷载计算 (26)5.2.1 恒载标准值计算 (26)5.3.1 楼⾯层传荷载 (30)5.3.2 柱⾃重 (33)5.3.3 附加偏⼼弯矩计算 (33)5.3.4 恒、活导荷图 (34)5.4竖向荷载作⽤下内⼒计算 (37)5.4.1 活载作⽤下的内⼒计算 (37)5.4.2 恒载作⽤下的内⼒计算 (50)5.5地震荷载计算 (53)5.5.1 地震荷载导荷 (53)5.5.2 地震荷载作⽤下的内⼒计算 (56)5.6风荷载的计算 (68)5.6.2 荷载作⽤下的内⼒计算 (70)5.7弯矩调幅 (82)5.7.1 ⽀座调幅 (82)5.7.2 ⽀座调幅后跨内(跨中)弯矩计算 (83) 5.7.3 按简⽀计算跨中弯矩 (86)5.8内⼒组合 (89)5.8.1 内⼒组合说明 (89)5.8.2 内⼒组合 (89)5.9框架结构配筋计算 (118)5.9.1 ⼆层横向框架梁截⾯设计 (118)5.9.2 框架柱的配筋计算 (125)6 柱下独⽴基础设计 (145)6.1确定地基的类型及基础的持⼒层 (145) 6.2荷载效应的组合 (145)6.2.1 地基承载⼒计算 (145)6.2.2 基础截⾯及配筋计算 (145)6.3框架柱下独⽴基础设计 (149)6.3.1 基础底⾯积的确定 (149)6.3.2 基础的抗冲切验算 (151)6.3.3 基础的抗冲切验算 (155)结束语 (158)致谢 (159)1 ⼯程概况和设计资料根据指导⽼师所给的计算任务书,本毕业设计是在所给的建筑施⼯图的基础上进⾏结构设计,其它专业的设计从略。
某办公楼计算书
目录摘要 (IV)ABSTRACT (V)1前言 (1)1.1框架结构的特点 (1)1.2框架结构的发展 (1)1.3本文研究的内容 (1)2建筑部分 (2)2.1工程概况 (2)2.2设计资料 (2)2.3.工程做法 (2)2.3.1屋面做法 (2)2.3.2楼面做法 (2)2.3.3门窗 (4)3结构部分 (5)3.1.结构布置 (5)3.1.1结构平面布置 (5)3.1.2确定梁柱截面尺寸 (5)3.2荷载标准值计算 (7)3.2.1恒荷载Gk (7)3.2.2活荷载Qk (10)3.2.3风荷载计算 (11)3.3内力计算 (11)3.3.1恒载作用下的内力计算 (11)3.3.2 活荷载的内力计算 (19)3.3.3风荷载作用下的内力计算 (27)3.4荷载组合及内力组合 (33)3.4.1横梁内力组合 (33)3.5框架梁柱配筋 (42)3.5.1横梁 (42)3.5.2框架柱 (44)3.6基础设计 (44)3.6.1基础梁 (44)3.6.2独立基础设计 (44)3.7板 (44)3.7.1双向板设计 (44)3.7.2单向板设计 (44)3.8框架连梁设计 (44)3.9次梁设计 (44)3.9.1荷载统计: (44)3.9.2截面设计 (44)3.10楼梯设计 (44)3.10.1楼梯板设计 (44)3.10.2平台板设计 (44)3.10.3平台梁设计 (44)4施工部分 (44)4.1编制依据 (44)4.2工程概况 (44)4.3施工方案 (44)4.3.1施工准备 (44)4.3.2施工段划分 (44)4.3.3施工机械 (44)4.3.4各工程组合施工进度安排 (44)4.4分项工程施工方法 (44)4.4.1脚手架 (44)4.4.2钢筋工程 (44)4.4.4模板工程 (44)4.5质量保证措施 (44)4.6施工现场监督检查 (44)4.7工期保证措施 (44)4.8施工部署 (44)4.8.1安全管理目标 (44)4.8.2文明工地管理目标 (44)4.8.3施工现场环境建设 (44)4.9雨季施工管理措施 (44)4.10施工现场环保措施 (44)4.11其它方面文明工地管理 (44)结论 (44)谢辞 (44)参考文献 (44)附录 (44)摘要本次毕业设计是某单位办公楼设计,主要进行的是结构设计部分。
办公楼结构设计手算计算书
1 结构设计说明1、结构方案选取选择合理的抗侧力结构体系,进行合理的结构或构件布置,使之具有较大的抗侧刚度和良好的抗风、抗震性能,是结构设计的关键。
同时还须综合考虑建筑物高度、用途、经济及施工条件等因素。
1.1竖向框架承重体系选取框架结构体系:由梁、柱构件通过节点连接而成,其具有建筑平面布置灵活、造型活泼等优点,可以形成较大的使用空间,易于满足多功能的使用要求。
在结构受力性能方面,框架结构属于柔性结构,自振周期长,地震反应较小,经合理设计可具有较好的延性性能。
其缺点是结构的抗侧刚度较小,在地震作用下侧向位移较大。
横向框架承重体系选取常见的横向承重体系包括:现浇楼盖、叠合楼盖、预制板楼盖、组合楼盖等。
现浇楼盖可分为肋梁楼盖、密肋楼盖、平板式楼盖和无粘结预应力现浇平板楼盖等。
肋梁楼盖结构具有良好的技术经济指标,可以最大限度地节省混凝土和钢筋的用量,能充分发挥材料的作用,结构整体性好,抗震性能好,且结构平面布置灵活,易于满足楼面不规则布置、开洞等要求,容易适用各种复杂的结构平面及各种复杂的楼面荷载。
1.3纵、横向混合承重体系选取在纵、横两个方向布置主梁以承担楼面荷载,就构成了纵、横向混合框架承重方案。
纵、横向混合框架承重方案具有较好的整体性,为空间受力体系。
本设计为六层的多层结构,根据功能使用性进行结构布置。
经各方案比较筛选,本工程选用框架结构的纵、横向承重体系。
2、楼梯方案的选择整体式楼梯按照结构形式和受力特点不同,可分为板式楼梯、梁式楼梯、剪刀式楼梯和圆形楼梯、螺旋楼梯等。
其中,应用较为经济的、广泛的是板式楼梯和梁式楼梯,剪刀式楼梯、圆形楼梯和螺旋式楼梯属于空间受力体系,外观美观,但结构受力复杂,设计与施工较困难,用钢量大,造价高,在实际中应用较少。
梁式楼梯由踏步板、斜梁、平台板和平台梁组成。
踏步板支承于两端的斜梁上,斜梁可设在踏步下面,也可设在踏步上面。
根据梯段宽度大小,梁式楼梯的梯段可采用双梁式,也可采用单梁式。
房屋建筑设计计算书(毕业设计)
第Ⅰ部分建筑设计1、工程概况:1.1 工程名称:xx家园1.2 工程位置:xx市xx路1.3 工程总面积:4383.7㎡,主楼7层,高22.5m,底层层高为4.5m,上部各层层高3m2、建筑物功能与特点:2.1平面设计建筑朝向为南北向,平面布置满足长宽比小于5,采用纵向4.5m、5.7m,横向7.2、4.8m的柱距,满足建筑开间模数和进深的要求。
2.2立面设计该建筑立面为了满足采光和美观需求,设置了大面积的玻璃窗。
外墙面选用面砖饰面,不同分隔区采用不同的颜色区隔,以增强美感。
2.3防火防火等级为二级,安全疏散距离满足房门至外部出口或封闭楼梯间最大距离小于35m,大房间设前后两个门,小房间设一个门,满足防火要求;室内消火栓设在走廊两侧,每层两侧及中间设3个消火栓,最大间距25m,满足间距50m的要求。
2.4屋面屋面形式为平屋顶;平屋顶排水坡度为2%,排水坡度的形式为垫置坡度,排水方式为天沟排水。
屋面做法采用98ZJ001中第78页屋六防水,刚性防水和高聚物改性沥青卷防水屋面。
3、设计资料3.1自然条件3.1.1 工程地质条件:详见地质勘查报告。
3.1.2抗震设防: 6度3.1.3防火等级:二级3.1.4建筑物类型:乙类= 0.40 kN/m2,主导风向:西北风3.1.5基本风压: W3.1.6基本雪压: S= 0.40 kN/m23.1.7地下水位:最低:-1.7 m 最高:-1.5 m3.1.8气象条件:年平均温度:12o C 最高温度:39o C 最低温度:-21o C年总降雨量:541.5 mm 日最大降雨量:115.5 mm 3.2工程做法3.2.1屋面做法——刚性防水和高聚物改性沥青卷防水屋面40厚C30UEA补偿收缩混凝土防水层满铺0.15厚聚乙烯薄膜一层3厚SBS改性沥青防水卷材基层处理剂一遍20厚1:2.5水泥砂浆找平层20厚1:8水泥膨胀珍珠岩找2%坡干铺100厚水泥膨胀珍珠板预制空心楼板3.2.2楼面做法1房间、走道楼面——陶瓷地砖地面(1)10厚地铺实拍平,水泥浆擦缝(2)25厚1:4干硬性水泥砂浆,面上撒素水泥(3)素水泥浆结合层一道。
毕业设计办公楼设计结构计算书(专业完整模板)
4.7梁柱内力组合表………………………………………………………………36
5、框架梁柱截面设计与配筋计算……………………………………………41
5.1框架梁截面设计………………………………………………………………41
5.2框架柱截面设计………………………………………………………………47
3.2框架柱抗侧移刚度计算………………………………………………………14
3.3集中风荷载标准值的计算……………………………………………………15
3.4各层柱反弯点位置及柱端剪力梁柱端弯矩的计算…………………………16
3.5风荷载作用下的内力图………………………………………………………18
4、竖向荷载作用下框架结构的内力分析……………………………………21
2、楼梯方案的选择
整体式楼梯按照结构形式和受力特点不同,可分为板式楼梯、梁式楼梯、剪刀式楼梯和圆形楼梯、螺旋楼梯等。其中,应用较为经济的、广泛的是板式楼梯和梁式楼梯,剪刀式楼梯、圆形楼梯和螺旋式楼梯属于空间受力体系,外观美观,但结构受力复杂,设计与施工较困难,用钢量大,造价高,在实际中应用较少。
板式楼梯由梯段板、平台板和平台梁组成。梯段板为带有踏步的斜板,其下表面平整,外观轻巧,施工支模方便,但斜板较厚,结构材料用量较多,不经济。故当梯段水平方向跨度小于或等于3.5m时,才宜用板式楼梯。
6.5中柱联合基础设计……………………………………………………………61
7、楼梯设计……………………………………………………………………65
7.1设计资料………………………………………………………………………65
7.2.梯段板计算……………………………………………………………………66
办公楼毕业设计——办公楼设计计算书
长安公司行政办公楼摘要本工程位于西安,采用框架结构,主体为六层,总建筑高度为20.70m,建筑面积为4263.8m2。
本地区抗震设防烈度为8度,近震,场地类别为II类场地。
主导风向为东北,基本雪压为0.2KN/m2。
楼、屋盖均采用现浇钢筋混凝土。
本设计主要进行了结构方案中横向框架第3轴抗震设计。
在确定框架布局之后,先进行了层间荷载代表值的计算,接着利用顶点位移法求出自震周期,进而按底部剪力法计算水平地震荷载作用下大小,进而求出在水平荷载作用下的结构内力(弯矩、剪力、轴力)。
接着计算竖向荷载(恒载及活荷载)作用下的结构内力。
是找出最不利的一组或几组内力组合。
选取最安全的结果计算配筋并绘图。
此外还进行了结构方案中的室内楼梯的设计。
完成了平台板,梯段板,平台梁等构件的内力和配筋计算及施工图绘制。
对楼板进行了配筋计算。
整个结构在设计过程中,严格遵循相关的专业规范的要求,参考相关资料和有关最新的国家标准规范,对设计的各个环节进行综合全面的科学性考虑。
总之,适用、安全、经济使用方面是本设计的原则。
设计合理可行的建筑结构方案是现场施工的重要依据。
关键词:框架结构;建筑设计;结构设计;抗震设计ChangAn company administration buildingAbstractThis work is a framework for a six-storey in Xi’an. Its height is 20.7 m and the area is4263.8 m2. In this region , the earthquake intensity is 8 degree and the site is Class 2 venues. Led to the northeast direction.The basic snow pressure is 0.20kN/m2.The floor and roof are using cast-in-place reinforced concrete structure.The design of the main structure of the program horizontal framework 3-axis seismic design. In determining the distribution framework, the first layer of representative value of the load, Then use vertex from the displacement method for earthquake cycle, and then at the bottom of shear horizontal seismic load calculation under size, then calculated the level of load under the Internal Forces (bending moment, shear and axial force). Then calculate vertical load (constant load and live load) under the Internal Forces. Identify the most disadvantaged group or an internal force several combinations. Select the best safety results of the reinforcement and Mapping. In addition, the structure of the program indoor staircase design. Completion of the platform boards, boards of the ladder, platform beam component and the reinforcement of internal forces calculation and construction mapping.In the whole structure of the design process, be strict compliance with the relevant professional standard,reference to relevant information and the latest national standards and specification and design of the various components of a comprehensive scientific considerations .In short ,application, security ,economic and user-friendly design is the principle . Reasonable and workable structure design of the program is the main basis for the site construction .Keywords:frame structure,architectural design,structural design,seismic design目录1 绪论 (1)1.1课题意义 (1)1.2框架结构简介 (1)2 建筑设计总说明 (2)2.1 工程名称 (2)2.2 设计要求 (2)2.3 自然条件 (2)2.4 平面设计 (2)2.5 交通部分平面设计 (2)2.5.1 过道设计 (3)2.5.2 门厅设计 (3)2.6 剖面、立面设计 (3)2.6.1 房屋高度确定 (3)2.6.2 采光、通风 (3)2.6.3 屋面设计 (3)2.6.4 楼面设计 (4)2.6.5 墙体设计 (4)2.6.6 建筑细部构造说明 (4)2.6.7 楼梯设计 (5)2.6.8 建筑细部构造做法 (5)3 结构设计 (7)3.1结构布置及计算简图 (7)3.1.1 梁和柱的截面尺寸估算 (7)3.2 重力荷载计算 (8)3.2.1 屋面永久荷载标准值 (8)3.2.2 楼面荷载标准值 (9)3.2.3 梁、柱、墙、窗、门等重力荷载 (9)3.3 各层重力荷载代表值计算 (10)3.3.1 第6层重力荷载代表值 (10)3.3.2 2-5层重力荷载代表值 (10)3.3.3 第1层重力荷载代表值 (11)3.4 框架侧移刚度计算 (12)3.4.1 横向框架侧移刚度计算 (12)3.4.2 柱的侧移刚度D值计算 (13)3.4.3 纵向框架侧移刚度计算 (15)3.5横向地震作用下框架结构的内力和侧移计算 (18)3.5.1 横向水平荷载作用下框架结构的侧移计算 (18)3.5.2 水平地震作用下框架的内力计算 (21)3.6 横向风荷载作用下框架结构内力和侧移计算 (23)3.6.1 风荷载标准值 (23)3.6.2 风荷载作用下的的水平位移验算 (25)3.6.3 风荷载作用下框架结构内力计算 (25)3.7 纵向水平荷载作用下框架结构的内力和侧移计算 (28)3.7.1 纵向自震周期的计算 (28)3.7.2 纵向水平地震作用及楼层地震剪力计算 (29)3.8 纵向风荷载作用下框架结构的内力和侧移计算 (32)3.8.1 风荷载标准值 (32)3.8.2 风荷载作用下纵向框架的内力计算 (33)3.9 竖向荷载作用下框架结构的内力计算 (34)3.9.1 横向框架内力计算 (34)3.10 横向框架的内力组合 (45)3.10.1 框架梁的内力组合 (45)3.11横向框架柱的弯矩和轴力组合 (50)3.11.1 横向框架A柱弯矩和轴力组合 (50)3.11.2横向框架B柱弯矩和轴力组合 (52)4 截面设计 (54)4.1 框架梁的设计 (54)4.1.1 第一层梁的配筋计算 (54)4.1.2 第二层梁的配筋计算 (55)4.1.3 第三层梁的配筋计算 (56)4.1.4 第四层梁的配筋计算 (57)4.1.5 第五层梁的配筋计算 (58)4.1.6 第六层梁的配筋计算 (59)4.1.7 梁的斜截面抗震验算及配箍筋 (60)4.1.8 柱的截面设计 (61)4.1.9 柱斜截面受剪承载力计算 (64)4.2 板的设计 (65)4.2.1 板的分格 (65)4.2.2 荷载计算 (65)4.2.3 弯矩计算 (66)4.2.4 板的配筋计算 (68)5 楼梯设计 (72)5.1 梯段板TB-1的设计 (72)5.1.1 荷载 (72)5.1.2 内力计算 (72)5.1.3 截面承载力计算 (72)5.2 梯段板TB-2的设计 (73)5.2.1 荷载 (73)5.1.2 内力计算 (73)5.1.3 截面承载力计算 (73)5.3 平台板的设计 (74)5.4 平台梁的设计 (75)5.4.1 确定平台梁的尺寸 (75)5.4.2 荷载计算 (75)5.4.3 内力计算 (75)参考文献 (77)致谢 (78)1 绪论1.1课题意义毕业设计是土木工程专业本科培养计划中最后的一个主要教学环节,也是最重要的综合性实践教学环节,目的是通过毕业设计这一时间较长的教学环节,培养土木工程专业本科生综合应用所学基础课、技术基础课及专业课知识和相关知识和相关技能,解决具体问题的土木工程设计问题所需的综合能力和创新能力。
土木工程毕业设计某综合办公楼计算书施工部分
第三章施工组织设计本施工组织设计作为指导施工的依据,编制时对项目管理机构设置、劳动力组织、施工进度计划控制、机械设备及周转材料配备、主要分部分项工程施工方法、工程质量控制措施、安全生产保证措施、文明施工及环境保护措施、降低成本措施等诸多因素尽可能充分考虑,突出科学性及可行性。
是确保优质、低耗、安全、文明、高速完成全部施工任务的重要经济技术文件。
本施工组织设计依据以下几项编制:(1)毕业设计任务书;(2)本工程初步设计图纸;(3)我国现行的施工验收规范和操作规程;(4)我国现行的有关机具设备和材料的施工要求及标准;(5)有关安全生产、文明施工的规定;3.1工程概况3.1.1 工程条件本工程为山东省某市市区某公司综合办公楼,共七层,层高为底层3.9m,标准层3. 6m。
室内外高差0.45米,室内地坪±0.000,建筑设计使用年限50年。
总建筑面积约为60 00 m2,建筑平面呈一字形,长51.6m、宽17,7m,该建筑物主体图见图纸:本工程承重结构为现浇钢筋混凝土框架,抗震设防为七度,结构计算考虑地震作用。
现浇楼板梁柱混凝土等级为C35,钢筋等级为HRB400。
,基础采用柱下独立基础,走廊处为联合基础,基础埋深1.3米,土方开挖采用大开挖的方式,基坑的放坡系数为0.30。
楼面、屋面及楼梯均为现浇。
地面采用磨光花岗岩地面;内外墙均为200mm,采用加气混凝土非承重墙,用M5混合砂浆砌;,内墙为普通抹灰,外墙装饰为陶瓷锦砖墙面;屋面防水为高聚物改性沥青防水卷材防水层;窗户采用PVC塑料门窗、铝合金玻璃窗,门采用实木门及铝合金门;设备安装及水、暖、电工程配合土建施工。
3.1.2 设计依据和条件(1)本工程建设地点为济南市中心区繁华地段,地形较为平坦。
持力层为粉质粘土层。
地下水呈弱碱性,对基础混凝土及其中的钢筋无侵蚀性。
最大冻深:-0.5m,0.45kN/m基本风压值:20.30kN/m。
基本雪压值:2(2)气象条件:施工期间正始春夏秋三季,雨季为七、八月,施工期不考虑冬季施工,主导风向西南风。
土木毕业7层设计计算书
毕业设计(论文)摘要毕业设计是土木工程专业的必修课程。
本毕业设计是教学楼设计。
设计的内容包括建筑设计和结构设计两部分。
设计的主体部分采用钢筋混凝土现浇框架结构,建筑层数为七层。
建筑总高度25.65m,底层占地面积为1307.7㎡。
根据设计要求,设防烈度为7度,抗震等级为三级,本设计中要考虑抗震设计。
设计包括建筑部分、结构部分、基础等。
根据任务书定出各层平面图及平面布置。
本方案主体结构为双向承重框架。
在进行荷载计算和构件截面估算后,选取了一榀框架进行计算,计算内容包括框架梁柱截面尺寸的选取及线刚度的计算;恒载、活载、地震作用下梁端、柱端弯矩、剪力的计算;框架内力组合;框架梁柱配筋计算;基础配筋计算。
框架受力钢筋主要采用Ⅱ级钢筋,箍筋主要采用Ⅰ级钢筋,楼梯采用钢筋混凝土梁式楼梯;由于柱网的限制,基础采用钢筋混凝土柱下独立基础。
整个方案设计基本符合设计和结构要求,具有一定的合理性。
通过对实验楼层平面图、剖面图、构造图的绘制和结构的设计,熟悉了设计的全过程,掌握了结构设计计算的基本方法,创造性地完成了毕业设计任务。
同时,对这些年所学的专业知识和基本概念有了更深的理解,从而提高了分析和解决实际问题的能力。
关键词:钢筋混凝土结构;框架结构;独立基础;荷载设计值D esign project for graduation is civil engineering special field of study required course .This graduation design is the design of teaching building. This design includes building design and construction design .Main part of this scheme adopts the cast-in-place frame structure of armored concrete. Structure rand order is four layers. Structure total height 25.65 meter ,the floor space of ground floor is 1307.7㎡. According to the designing requirement, the earthquake intensity is 7 degrees to set up defence, the grade of antidetonation is three scale. This building consider aseismatic design in the design. Design project include construction part、structure part and foundation. According to assignment book define every layer ichnography and plane arrange. The agent structure is a two-way bearing frame. In this it is it calculate and component section after estimating , choose one Pin frame calculate to load to go on, consideration substance include select frame column section measurement and thread rigidity ,calculate dead loads and live loads and seismic action produce roof beam extremity and column extremity bending moment 、shear and axle power; Frame internal force make up; Mate steel and foundation mate steel calculate. Frame be subject to power steel adoptⅡlevel and hoop steel adoptⅠlevel. Stairs adopt steel concrete type of meter for chinese and foundation adopt linear leaf. The whole conceptual design accords with the design and structure demand basically, have certain creativity and rationality.Through the design of laboratory floor construction, and drawing floor plan,constructed profile and constructional drawing, I am familiar with the principle design of construction, and controlled the basic methods of computation of the construction design, and my work is creative. At the same time, I have a deeper understanding of the first several years’ profession learning and the foundation knowledge. As a result, my ability about analyzing and solving the actual problems is improved.Key words:Reinforced concrete structure;frame structure;linear leaf foundation;design value of a load摘要 (1)Abstract (2)目录 (3)绪论 (4)1 工程概况 (4)1.1 平面设计 (4)1.2 剖面设计 (4)1.3 排水设计 (5)1.4 结构选型 (5)1.5 设计原始数据 (5)1.6 技术要求 (5)1.7 工作要求 (6)2 构件截面尺寸和材料选择 (6)2.1 构件截面尺寸的初定 (6)2.2 材料选择 (8)3 结构计算简图及框架侧移刚度计算 (8)3.1 框架结构计算简图 (8)3.2 框架侧移刚度计算 (9)4 重力荷载统计计算 (13)4.1 横荷载计算 (13)4.2 楼面活荷载计算 (15)4.3 风荷载计算 (17)4.4 横向水平地震荷载计算 (23)5 竖向荷载作用下框架结构的内力计算 (31)5.1 计算单元的选取确定 (32)5.2 荷载计算 (32)6 荷载效应组合 (39)6.1 梁内力组合 (43)6.2 柱的内力组合 (48)7 截面设计 (56)7.1 横向框架截面设计 (56)7. 2 框架柱截面设计 (60)7. 3 首层楼板设计 (64)8 基础设计 (72)8.1 J-1基础类型及计算形式 (72)8.2 J-2基础类型及计算形式 (78)结束语 (79)参考文献 (80)毕业设计是我们在学校期间的最后一次实践性的锻炼,通过毕业设计使我们系统地、综合地、灵活地运用学到的各种理论知识,解决建筑工程中的实际问题,通过毕业设计,使我们在分析、使用技术资料、计算、绘图、编写设计文件及独立工作等方面得到全面锻炼。
毕业设计办公楼建筑结构设计
毕业论文 (二稿)题目:新建二中综合办公楼建筑结构设计院系:专业:班级:学号:XX:指导老师:2014.4摘要本设计是一幢七层钢筋混凝土框架结构办公楼的设计,设计内容包括:建筑设计和结构设计两部分。
结构设计是在建筑物初步设计的基础上确定结构方案;选择合理的结构体系;进行结构布置,并初步估算,确定结构构件尺寸,进行结构计算。
本设计主要对结构方案中横向第4榀框架进行了结构设计。
在确定框架平面布置方式之后,首先进行了层间荷载标准值的计算,接着采用二次弯距分配法计算得出竖向恒荷载和活荷载作用下的结构内力。
然后,利用D值法求出在水平风荷载作用下的结构内力(弯矩、剪力、轴力)。
其次,对各种情况下的内力进行了组合,选取最安全的结果进行框架梁、框架柱截面的配筋计算。
然后,对板、楼梯、基础的结构进行了设计。
最后,利用PKPM和CAD软件绘制了框架结构的施工图。
【关键词】:框架结构,抗震设计,荷载设计,二次弯距分配法,独立基础,结构配筋AbstractThis design is an seven layer of reinforced concrete frame structure dormitory ;It includes two parts-architecture design and structure design.In the structure design,determine the structure design based on architecture first design.Select the right structure type.Precede structure arrangement and sizes of structure components to calculate.The 4th horizontal frame structure is designed in this design. After determining the frame layouts, the standard values of loads acting on the structure are calculated firstly. Then the internal forces of the structure caused by vertical constant load and live load are calculated by Secondary bending moment distribution method. Then, the structural internal forces (moment, shear force and axial force).due to horizontal wind load is calculated by using a D value method. Secondly, the internal forces under various circumstances are combined. The security results are selected to calculate the reinforcement of frame beams and frame column. Then, the structure of the independent footing is designed. Finally, the shop drawing of the frame structure is drawn by PKPM and CAD software.Key words:Frame structure,Seismic Design,Load Calculation,Secondary bending moment distribution method,Independent footing,Structure Reinforced目录第一章设计资料 (4)1.1工程概况 (4)1.2地质水文条件 (4)1.3气象条件 (5)1.4材料使用 (5)1.5荷载资料 (5)1.6门窗 (6)第二章结构设计 (7)2.1 结构选型和布置 (7)2.2 框架的计算简图 (10)第三章荷载计算 (15)3.1荷载计算 (15)第四章内力计算 (24)4.1恒载作用下的框架内力 (24)4.2 活载作用的框架内力计算 (30)4.4 风荷载作用下的位移、内力计算 (35)4.5 地震作用下横向框架的位移、内力计算 (44)第五章框架内力组合 (55)5.1 荷载组合 (55)第六章框架梁、柱截面设计 (77)6.1 框架梁截面设计 (77)6.2 次梁截面设计 (90)6.3 板截面设计 (92)第七章现浇楼面板、楼梯设计 (97)7.1 楼梯设计 (97)第八章基础设计 (102)8.1 基础结构设计 (102)8.2 柱B、C采用联合基础设计 (105)参考文献 (108)谢辞 (109)第一章设计资料1.1工程概况(1)工程名称:XX市新建二中综合办公楼(2)建筑概况:该办公楼为七层钢筋混泥土结构体系,建筑面积约4000m2,建筑总高度21.3m,采用室内楼梯,室内外高差为0.60m,建筑使用年限为50年。
某办公楼框架结构毕业设计计算书
某办公楼框架结构毕业设计计算书目录第一章设计说明1.1 建筑设计说明 (4)1.2 结构设计说明 (5)第二章结构平面布置2.1 柱网布置 (5)2.2 框架结构承重方案选择 (6)2.3 框架梁、柱截面尺寸确定 (6)第三章荷载标准值计算3.1 恒载标准值计算 (11)3.2 活载标准值计算 (16)3.3 计算竖向荷载作用下框架受荷总图 (16)3.4 风荷载计算 (22)3.5 地震荷载作用下的内力和位移计算 (26)3.6 横向框架的水平地震作用和侧移计算 (29)第四章内力计算4.1 恒载内力计算 (35)4.2 活载内力计算 (43)4.3 重力荷载内力计算 (49)4.4 风荷载标准值作用下内力计算(D值法) (55)4.5 水平地震作用下的内力计算(D值法) (62)第五章内力组合5.1 内力组合一般规定 (69)5.2 框架梁内力组合 (70)5.3 框架柱内力组合 (74)第六章框架梁、柱截面设计6.1 框架梁截面设计 (77)6.2 框架柱截面设计 (82)第七章基础设计7.1 工程概况 (91)7.2 框架柱传来荷载确定 (91)7.3 柱下独立基础设计 (92)7.4 抗冲切验算 (96)7.5 柱下独立基础的局部受压验算 (97)7.6 基础配筋验算 (97)前言毕业设计是大学本科教育培养目标实现的重要阶段,是毕业前的综合学习阶段,是深化、拓宽、综合教和学的重要过程,是对大学期间所学专业知识的全面总结。
本组毕业设计题目为《某办公楼框架结构设计》。
在毕设前期,我温习了《结构力学》、《钢筋混凝土》、《建筑结构抗震设计》等知识,并借阅了《抗震规范》、《混凝土规范》、《荷载规范》等规范。
在毕设中期,我们通过所学的基本理论、专业知识和基本技能进行建筑、结构设计。
特别是在SARS肆掠期间,本组在校成员齐心协力、分工合作,发挥了大家的团队精神。
在毕设后期,主要进行设计手稿的电脑输入,并得到老师的审批和指正,使我圆满的完成了任务,在此表示衷心的感谢。
办公楼毕业设计计算书4
17:楼梯计算:1号楼梯计算(底层)17.1.1梯段板计算设板厚120h mm =,板倾斜角1500.5,cos 0.894300tg αα===,取1m 宽板带计算 ①荷载计算梯段板的荷载计算列于表45,荷载分项系数 1.2, 1.4G Q γγ==,基本组合的总荷载设计值 1.2 6.6 1.4 3.512.82p KN =⨯+⨯=表45:梯段板的荷载计算②截面设计板水平计算跨度 3.6n l m =,弯矩设计值2210.112.82 3.616.6110n M Pl KN M ==⨯⨯=⋅ 板的有效高度012020100h mm =-=6221016.61100.1739.61000100s c M f bh αα⨯===⨯⨯ ((0.510.510.904s γ=⨯== 62016.6110790.952100.904100Y s M As mm F h γ⨯===⨯⨯⨯⨯选配φ10@100,实有2785As mm =,分布筋每级踏步一根φ8.梯段板配筋见图17.1.2平台板设计①设平台板厚100mm ,取1米宽板带计算,平台板荷载计算列于表46。
表46:平台板荷载计算总荷载设计值: 1.2 3.49 1.4 3.59.088/P KN M =⨯+⨯= ②截面设计平台板的计算跨度:0300200L 1800165022=--= 弯矩设计值:220119.088 1.65 2.471010M PL KN M ==⨯⨯=⋅ 板有效高度01002080H =-=m m62210 2.47100.04021.09.6100080s c M f bh αα⨯===⨯⨯⨯((0.510.510.979s γ=⨯==620 2.4710150.182100.97980Y s M As mm F h γ⨯===⨯⨯⨯⨯ 选配φ8@200,实有2251As mm =17.1.3平台梁设计设平台梁截面尺寸200400mm ⨯ ①荷载计算平台梁的荷载计算列于表47中。
办公楼毕业设计计算书4(20210409081716)
(最新)办公楼毕业设计计算书4-CAL-FENGHAI-(2020YEAR-YICAI) JINGBIAN17 :楼梯计算:1号楼梯计算(底层)17.1.1梯段板计算设板片力= 120〃w板倾斜角/ga = U^ = 0.5,cosa = 0・894,取lm宽板带计算300①荷载计算梯段板的荷载计算列于表45,荷载分项系数沧=12沧=1.4,基本组合的总荷载设计值“ =1.2 x 6.6 +1.4 x 3.5 = 12.82KN表45:梯段板的荷载讣算板水平计算跨度人=3.6m ,弯矩设计值M= —=0・lxl2・82x3・62 =16・61KN・M10板的有效高度/?() = 120-20 = 100mmM _ 16.61X10&" 9.6x1000x1002人=0.5 x (1 + Jl-2aj = 0.5 (1 + 71-2x0.173)= 0.9044M 16.61X106口、2 2As = -------------- =---------------------- = 790.95〃〃"F y x/y x/?0210x0.904x100选配“ 10@100,实有加=785〃加,分布筋每级踏步一根“ 8.梯段板配筋见图17.1.2平台板设计①设平台板厚100〃〃〃,取1米宽板带计算,平台板荷载计算列于表46°= 0.173表46:平台板荷载计算荷载种类荷载标准值 (KN/M )水磨石面层恒荷载100厚混凝土板0.1x25=2.5 板底抹灰0.02x17 = 0.34小计活荷载3.5总荷载设计值:P = l ・2x3・49 + l ・4x3・5 = 9・088&V/M②截面设计平台板的计算跨度:L o = 18OO- —= 1650 2 2弯矩设计值:M =丄=丄x 9・088 x 1.652 = 2.47KN ・M 10 10 板有效高度丹。
某行政办公楼结构设计计算书
目录1基本建设条件及要求 (3)1.1工程地质条件 (3)1.2气象条件 (3)1.3建设规模 (4)1.5建筑设计 (4)1.5.1设计要求 (4)1.5.2图纸要求 (4)1.6结构设计 (5)1.6.1设计要求 (5)1.6.2结构计算容 (5)1.6.3结构施工图 (5)1.7建筑材料选用 (5)2结构布置 (7)2.1结构平面布置 (7)2.2梁、柱截面尺寸的确定 (7)3.1屋面及楼面的永久荷载 (9)3.2屋面及楼面可变荷载 (10)3.4荷载分层总汇 (11)4 框架梁截面设计 (12)4.1 梁的正截面计算与配筋 (12)4.2 梁斜截面计算与配筋 (14)5框架柱计算 (17)5.1柱正截面计算与配筋 (17)5.2柱斜截面计算与配筋 (20)6 楼梯的设计与计算 (22)6.1结构设计 (23)6.1.1楼梯梯段板的计算 (23)6.1.2荷载计算 (23)6.1.3力计算 (23)6.2平台板的计算 (24)6.2.1荷载计算 (24)6.2.2力计算与配筋计算 (24)6.3平台梁计算 (25)6.3.1荷载计算 (25)6.3.2力计算 (25)6.3.3配筋计算 (25)7 楼板设计计算 (26)7.1 荷载设计值 (27)7.2弯矩计算 (27)7.3 截面配筋设计 (29)结束语 (30)参考文献 (31)某行政办公大楼结构设计摘要该项目建于市区,场地地形平整,建设用地不受限制,与周围建筑的交通便利,周围建筑物环境对本建设项目无特殊要求。
建筑采用钢筋混凝土框架结构,首先,根据设计出的建筑方案及所选用的建筑材料及做法,确定结构计算简图,进行荷载和力计算,其次,确定结构控制截面的弯矩、剪力和轴力设计值,最后,根据已经计算出的结构控制截面的力值,对梁、板、柱、基础等进行配筋计算,并绘制相应的结构施工图。
关键词:框架结构;力计算;配筋计算1基本建设条件及要求1.1工程地质条件(1)地场土层:(自上而下)第一层填土:土质松软,结构不匀,不应作拟建建筑物的天然地基,土层厚度0.4~1.0m。
办公楼建筑结构施工毕业设计计算书【最全】
第一章建筑设计说明 (1)1.1 工程概况 (1)1.2建筑功能设计 (1)1.3建筑立面设计 (2)1.4建筑物构造做法 (2)第二章结构设计计算 (10)2.1 结构方案选择 (10)2.1.1 结构选型 (10)2.1.2 结构布置 (12)2.1.3 主要构件截面尺寸的确定 (14)2.2材料的选择 (15)2.2.1混凝土 (15)2.2.2钢筋及保护层 (15)2.2.3.围护结构墙体 (15)2.3 重力荷载计算 (15)2.3.1局部七层屋顶恒荷载 (15)2.3.2六层恒荷载 (17)2.3.3五层横荷载 (22)2.3.4三四层横荷载 (26)2.3.5一层和二层横荷载 (30)2.4 横向水平地震作用计算及弹性变形验算 (34)2.4.1计算简图及重力荷载代表值的计算 (34)2.4.2框架刚度的计算 (37)2.4.3框架自振周期计算 (38)2.4.4多遇水平地震作用标准值和位移计算(采用底部剪力法) (42)2.4.5抗震变形验算(层间抗震位移验算) (42)2.5 横向水平地震作用下的框架内力计算(14轴框架) (42)2.5.1框架柱剪力和柱端弯矩标准值计算(见表2-8) (42)2.5.2框架梁端弯矩、剪力、柱轴力计算(见表2-9) (44)3.柱轴力见下图2-11 (46)2.5.3 框架内力图 (48)2.6 竖向荷载作用下框架内力计算——采用弯矩二次分配法 (50)2.6.1无地震作用时 (50)2.6.2 有震作用下重力荷载代表值作用计算见简图2-27 (74)2.7 横向框架内力组合 (92)2.7.1梁端截面弯矩计算 (92)2.7.2 梁弯矩内力组合 (92)2.7.3 梁端剪力组合 (93)2.7.4 柱弯矩与柱轴力组合 (93)2.7.5 柱剪力组合 (117)2.8 框架梁、柱和节点的抗震设计 (117)2.8.1一般的设计原则 (117)2.8.2横向框架梁设计 (117)第三章深基施工组织设计 (151)3.1工程概况 (151)3.1.1施工条件 (151)3.2施工方案选择 (152)3.2.1施工程序和施工顺序 (152)3.2.2施工段划分和施工流向 (152)3.2.3 垂直运输机械 (155)3.2.4 确定施工方法 (155)3.3施工进度计划 (200)3.3.1编制原则 (200)3.3.2编制依据 (200)3.3.3编制步骤和方法 (200)3.4主要资源供应计划 (201)3.4.1劳动力供应计划见表3-2 (201)3.4.2机械设备供应计划见表3-3 (202)3.5施工现场平面图设计 (203)3.5.1深基础工程施工平面图设计内容 (203)3.5.2 施工平面图设计原则 (203)3.5.3施工平面图设计说明 (203)3.6 技术组织措施 (204)3.6.1季节施工措施(雨季施工措施) (204)3.6.2质量保证措施 (205)3.6.3 安全保证措施 (206)3.6.4环境保护措施 (210)3.6.5文明施工措施 (212)第四章工程造价计算 (214)4.1工程量计算 (214)4.1.1建筑面积 (214)4.1.2土方及基础工程计算 (214)4.1.3主体钢筋工程计算 (215)4.1.4地下室门窗工程 (219)4.1.6地下室地面工程 (221)4.1.6地下防水工程 (222)4.1.7地下内外装饰工程 (223)4.1.8土建工程施工措施项目 (223)4.1.9装饰装修工程施工措施项目 (224)4.2施工图预算 (224)4.3工程量清单计价 (246)致谢 (270)参考文献 (271)第一章建筑设计说明1.1 工程概况1.工程名称:天津市南开区教育中心综合楼2.建设地点: 该工程所处位置位于南开区东南靠近友谊路北靠大沽路,占地面积3871.72平方米,建筑物西侧为菜市场,东侧为北京现代汽车公司,距周围最近建筑距离均大于6m,四周设有便于车辆行驶的环形车道,满足现场施工运输的规定。
毕业设计计算书(实例某写字楼)
1绪论本设计是按照******建筑工程学院2008年毕业设计要求编写的毕业设计。
题目为“******办公楼设计”。
内容包括建筑设计、结构设计两部份。
办公楼是公共建筑,其规范要求比较严格,能体现处建筑和结构设计的很多重要的方面,选择办公楼建筑和结构设计,从而掌握办公楼设计的基本原理,妥善解决其功能关系,满足使用要求。
框架结构的设计始于欧美,二十世纪后得到了世界各地大范围的使用,其结构建筑平面布置灵活,使用空间大。
延性较好。
其具有良好的抗震能力。
对办公楼有重要建筑结构非常适用。
能满足其较大的使用面积要求。
框架结构的研究,对于建筑的荷载情况,分析其受力,采用不同的方法分别计算出各种荷载作用下的弯矩、剪力、轴力,然后进行内力组合,挑选出最不利的内力组合进行截面的承载力计算,保证结构有足够的强度和稳定性。
在对竖向荷载的计算种采用了弯矩分配法,对水平荷载采用了D值法,对钢筋混凝土构件的受力性能,受弯构件的正截面和斜截面计算都有应用。
本结构计算选用一榀框架为计算单元,采用手算的简化计算方法,其中计算框架在竖向荷载下的内力时使用的弯矩二次分配法,不但使计算结果较为合理,而且计算量较小,是一种不错的手算方法。
本设计主要通过工程实例来强化大学期间所学的知识,建立一个完整的设计知识体系,了解设计总过程,通过查阅大量的相关设计资料,提高自己的动手能力。
这次设计是在结构教研室各位老师的悉心指导下完成的,在此向你们表示衷心的感谢!鉴于水平有限,设计书中还存在不少缺点甚至错误,敬请老师批评和指正。
2建筑说明与结构设计说明2.1设计资料1、工程名称:******写字楼。
2、工程地点:花园路、纬一路交叉口。
3、场地概况:场地地势平坦,建筑条件良好,持力层为粉土,地基承载力标准值fk=160kpa.4、水文资料:勘察期间,在勘探深度15.6m以内未见到地下水。
由于地下水位埋藏较深设计和施工中不考虑其影响。
5、气象资料:主导风向,西北风。
办公楼毕业设计计算书完整版
办公楼毕业设计计算书 HUA system office room 【HUA16H-TTMS2A-HUAS8Q8-HUAH1688】目录目录................................................................1 绪论..............................................................1.1 工程概况....................................................1.2 设计内容与方法..............................................2 建筑设计..........................................................2.1建筑构造做法.................................................2.2其他建筑设计.................................................3 结构设计..........................................................3.1 设计依据....................................................3.2 荷载取值....................................................3.3 结构计算原则和方法..........................................4. 结构布置.........................................................4.1 结构布置方案构件尺寸........................................4.2 确定结构计算简图............................................4.3 梁、柱惯性矩、线刚度计算....................................5.荷载计算.........................................................5.1 恒载标准值计算..............................................5.2 活载标准值计算..............................................5.3 风荷载标准值计算............................................ 6.内力计算.........................................................6.1恒荷载作用下的内力计算.......................................6.2活载作用下的内力计算.........................................6.3风荷载作用下的内力计算....................................... 7.内力组合.........................................................7.1竖向荷载弯矩调幅.............................................7.2框架梁内力组合...............................................7.3框架柱内力组合............................................... 8.截面设计.........................................................8.1框架梁截面设计...............................................8.2框架柱截面设计............................................... 9板的设计...........................................................9.1板的结构平面布置图...........................................9. 2荷载计算....................................................9. 3弯矩计算....................................................9. 4截面设计....................................................10.楼梯设计.........................................................10.1 梯段板设计.................................................10.2 平台板设计.................................................10.3 平台梁设计.................................................11. 基础设计........................................................11.1 基础设计参数...............................................11.2 确定基础底面面积...........................................11.3 持力层强度验算.............................................11.4 基础冲切验算...............................................11.5 基础配筋计算...............................................1 绪论1.1 工程概况此工程建于江西省南昌市(某企业4#办公楼建筑结构设计),工程采用框架结构,建筑抗震设防类别丙类,设计使用年限50年,耐火等级为二级,抗震设防烈度6度,地震分组为第二组,类建筑场地;基本雪压0.3kN/m2;基本风压0.45kN/m2,地面粗糙程度为B类;地基允许承载力为f ak=80kPa。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
毕业设计题目:通州东润办公楼学院:土木建筑学院专业名称:土木工程班级学号: 11111129 学生姓名:指导教师:毕业设计(论文)任务书I、毕业设计(论文)题目:通州东润办公楼设计II、毕业设计(论文)使用的原始资料(数据)及设计技术要求:1.工程概况本工程建筑面积5000平方米。
框架结构。
底层设门厅、休息室、值班室、传达室。
二层为办公区,顶面两层层设有大、小会议室。
层高在3.6-4.2m之间。
本地区气象资料按城市气象资料查询。
2.场地概述地质条件:场地平坦,土质均匀,无不良地质发育;地基土为厚度较大的粘性土层,地基土承载力f ak =210 kP a,地下水埋藏较深,不考虑地下水影响。
I II、毕业设计(论文)工作内容及完成时间:1.第4~5周:查阅有关文献资料,完成开题报告和科技文献翻译(同时实习)。
2.第6-8周:建筑设计部分:建筑设计说明、门窗表、.建筑物的平面、立面、剖面、主要结点构造设计;绘制底层平面图、标准层平面图、屋顶平面图、立面图、典型剖面图、楼梯、屋顶泛水等详图。
3.第9-12周:结构设计部分:根据建筑设计、地质条件、施工技术条件材料供应等,确定结构方、案进行结构布置,确定构件编号和定位尺寸,楼板受力分析与截面设计,框架受力分析与截面设计,基础设计,现浇楼梯设计计算。
4.第13-14周:绘制以下结构施工图:基础平面布置图,框架柱基础配筋图,楼面结构平面布置图,屋面结构平面布置图,框架模板配筋图,现浇楼梯施工图,PKPM复核。
5.第 15周:整理设计计算书、图纸等设计文件。
6. 第 16周:准备答辩。
Ⅳ、主要参考资料:[1].GB50010-2010混凝土结构设计规范. 北京:中国建筑工业出版社,2010.[2].GB50009-2012 建筑结构荷载规范. 北京:中国建筑工业出版社,2012.[3].GB50007-2011 建筑地基基础设计规范. 北京:中国建筑工业出版社,2011.[4].GB50011-2010 建筑抗震设计规范. 北京:中国建筑工业出版社,2010.[5].沈蒲生主编,混凝土结构设计.北京,高等教育出版社,2012.[6].朱斌惠主编.建筑施工图识读与应用实例.北京:中国建材工业出版社,2012.[7].赵青主编,土木工程专业毕业设计指导,武汉大学出版社,2013.[8].高等学校毕业设计(论文)指导手册土建卷.北京,高等教育出版社,2012通州东润办公楼设计摘要:该办公楼位于北京市,交通便利,各种生活、生产设施齐全。
该工程为矩形建筑,东西长43.2m,南北长16.2m,总建筑面积约5000m²,建筑高度25.6m,7层高,层高3.6m,该办公楼满足办公、会议要求。
结构设计密切联系建筑设计,一现行的有关规范为依据,主要包括结构选型及结构布置、确定计算简图及计算单元、荷载计算、侧移控制、内力组合、构件设计、楼梯设计、基础设计等内容。
本工程采用钢筋混凝土框架结构体系(双向承重),选择了有代表性的一榀框架进行计算。
对于竖向荷载作用采用弯矩二次分配法计算,水平荷载作用采用反弯点法计算。
由于本工程位于8度抗震设防区,属于丙类建筑,所以计算时考虑抗震要求,同时必须满足规范规定的构造要求。
此外还进行了框架外的楼梯和基础的设计:对楼梯采用的是板式楼梯,计算了梯段板、梯段斜梁,平台梁、平台板;对基础采用了独立基础与联合基础,也计算了独立基础和联合基础。
关键词:办公楼钢筋混凝土框架结构体系弯矩二次分配法反弯点法指导老师签名:The Farm Bureau office building Design of BeiJing CityAbstrct: The village,located at the east of beijing City, has convenient transport facilities and a variety of living and production facilities. The rectangular building projects, is 43.2m from east to west and 16.2m from north to south, total construction area of which is about 5000m ², building height is 25.6m, has7-storeys, the height of ground floor is 3.6m ,The office building meets the requirements of office work and entertainment.Structural design is closely contacted with architecture, based on existing relevant specifications, includes selection and structural layout of the structure to determine the calculated diagram and the calculation unit, load calculation, lateral control, internal force composition, component design, stair design, foundation design and so on. The project takes reinforced concrete frame structure (Two-way bearing system), choose a representative unit to calculate the framework. Using Moment Distribution Method for the vertical load calculation and Inflection point method for horizontal loads. During the process of Design and calculation took into account the whole technical and economic indicators and construction requirements of industrialization, as the project is located at8 degree earthquake zone, so the calculation does take into account the seismic requirements.And must meet the construction requirements specification Also conducted the staircase outside the framework and foundation design: use the beam staircase, calculate the bench inclined beam, bench plate, flat beam, the platform plate; use an joint foundation and an independent basis for the calculation of,independent foundation and joint foundation.Keywords:Vi l lage office building , Reinforced concrete frame structure ,Moment Distribution Method ,Inflection point methodSignature of Supervisor目录前言 (1)1 工程概况及原始资料 (2)1.1 工程概况 (2)1.2 设计资料 (2)1.3平面布置 (2)2 板的计算2.1 设计资料 (3)2.2 屋面板计算 (4)2.3 楼面板计算 (6)3 框架结构设计3.1 结构选型及材料选用 (8)3.2 框架计算简图及梁柱线刚度 (9)3.3 荷载计算 (9)3.4 风荷载作用下的位移验算 (14)3.5 地震荷载作用下位移验算 (20)3.6内力计算 (26)3.7 内力组合 (34)3.8 梁截面设计与配筋计算 (39)3.9 柱截面设计与配筋计算 (43)4 楼梯设计4.1 标准层楼梯设计 (46)4.2 梯段板设计 (46)4.3 平台板设计 (47)4.4 平台梁设计 (48)5 基础设计5.1 设计资料 (50)5.2 A轴柱独立基础设计 (50)5.3B,C轴柱下联合基础设计 (53)参考文献 (56)致谢 (66)前言毕业设计是本科教育培养目标实现的重要阶段,是毕业前的综合学习阶段是深化、拓宽、综合教和学的重要过程,是对大学期间所学专业知识的全面总结。
本次毕业设计题目为《通州东润办公楼设计》。
在毕设前期,我重新学习《结构力学》、《混凝土结构设计原理》、《混凝土结构设计》和《基础工程》等知识,并借阅了《抗震规范》、《混凝土结构设计规范》、《荷载规范》等规范。
在毕设中期,我通过所学的基本理论、专业知识和基本技能进行建筑、结构设计并积极请教指导老师。
在老师的精心指导下,在规定的时间内完成了建筑设计,结构设计,手算一榀框架及PKPM软件计算。
在毕设后期,主要进行设计手稿的电脑输入,排版及相应图片的插入,并得到老师和同学们在毕设中的指导批正,使我在自我所学的基础上完成了任务,在此表示衷心的感谢。
在毕设的期间,在指导老师的帮助下,经过资料查阅、设计计算、论文撰写以及外文的翻译,加深了对新规范、规程、手册等相关内容的理解。
巩固了专业知识、提高了综合分析、解决问题的能力。
在进行内力组合的计算时,进一步了解了Excel、Word。
在绘图时熟练掌握了AutoCAD、天正软件及PKPM,以上所有这些从不同方面达到了毕业设计的目的与要求。
框架结构设计的计算工作量很大,在计算过程中以手算为主,辅以一些计算软件的校正。
由于自己水平有限,难免有不妥和疏忽之处,敬请各位老师批评指正。
1 建筑设计及原始资料1.1工程概况该办公楼位于北京市,交通便利,各种生活、生产设施齐全。
该办公楼满足底层设门厅、休息室、值班室、传达室。
二层为办公区,顶面两层层设有大、小会议室建筑面积:5000m2,共7层,层高3.6m,钢筋混凝土框架结构体系,结构抗震设防防烈度8度,抗震等级为一级,基础采用柱下独立基础和联合基础。