穿垫区说明

合集下载

ISOFLEX 压力管理床垫使用说明书

ISOFLEX 压力管理床垫使用说明书

ISOFLEX®Pressure Management MattressInstructions for UseRead and understand the operating instructions and all safety precautions prior to use. SymbolsConsultInstructions forUseDo not tumble dryFoot end ofmattressDo not ironLatex freeDo not dry cleanDamp wipe onlyAllow to completely air dry10%ChlorinatedBleachSAFETY PRECAUTIONSWarning:•ISOFLEX mattress covers (top and bottom) should be inspected for tears, punctures, excessive wear, and misaligned zippers each time the covers are cleaned. If a mattress cover becomes compromised, themattress should be removed from service immediately to prevent cross contamination.Caution:•When utilizing an X-Ray plate while the patient is on ISOFLEX, take precautions to insure that no sharp edges from the X-Ray plate come in contact with the mattress cover. It is recommended that a pillow case, or some other protective device, is placed on the plate prior to placement under the patient. If a mattress cover becomes compromised, the mattress should be removed from service immediately to prevent cross contamination.•When cleaning the underside of the mattress, insure that no liquid is allowed to seep in to the zipper area and watershed cover barrier, fluids allowed to come in contact with the zipper may leak in to the mattress.•Check patient’s skin regularly. Consult physician if any redness or skin break occurs. Serious injury could result if the patient’s skin condition is left untreated.•The patient’s skin should be checked and assessed every 8 hours, or once per shift, to insure proper mattress performance.Intended UseISOFLEX mattresses provide pressure redistribution for patients with existing, or who are at risk of developing, pressure ulcers.Unpacking Instructions:1. Remove the mattress from the box.2. Lay the mattress on its side.3. Using scissors, carefully cut the sleeve that holds the folded mattress. Becareful not to inadvertently cut the mattress.4. Remove and discard the sleeve.5.Set up Instructions:1. Place the ISOFLEX mattress on the bed frame. Insure that the mattress properly fits the bed frame on whichit is being placed. Using an ISOFLEX mattress on a bed frame of a larger or smaller width than the stated ISOFLEX width may result in the mattress sliding and patient injury.2. Insure that the foot end symbol ( ) is located at the foot end of the bed frame. ISOFLEXmattresses are equipped with a dedicated sloped heel section and must be installed with this section at the foot end of the bed frame.3. Place the linens on the mattress leaving them as loose as possible to avoid creating a “hammocking” effectand increasing interface pressures.4. Place the patient on the mattress.Cleaning Instructions:1. Gaymar mattress surfaces are designed for long-lasting comfort and reliability. In order to maintain theseproducts, they should be cleaned regularly using soap and water and a hospital grade disinfectant. Gaymar recommends these disinfecting agents: Ecolab® Airkem® A-33 Quaternary Solution, 3M® Phenolic Disinfectant Cleaner Concentrate Solution Product #18, or a 10% Chlorinated Bleach Solution.2. Alcohol is not recommended because it can discolor and degrade the cover.3. Allow to completely dry. The solution contact time is what makes the disinfectant process effective.4. Wipe down the mattress with a clean dry cloth to remove any excess disinfectant.NOTE: The cover must be dry prior to storage or application of linens. Failure to remove excess disinfectant could eventually degrade the cover.5. An antimicrobial agent has been used to help prevent bacteria and fungus from destroying the coating of thecover. Should unsightly stains, discoloration, brittleness, stickiness, or unpleasant odors become noticeable, the antimicrobial agent may have become ineffective and the product should be replaced.Distributed by: Stryker Medical3800 East Centre Avenue Portage, MI 49002 USA Copyright:©2010. Stryker Medical, Inc. All rights reserved.Trademark Information:Stryker is a registered trademarks of Stryker Medical.ISOFLEX is a trademark of Gaymar Industries, Inc.Ecolab and Airkem are registered trademarks of Ecolab Inc.3M is a registered trademarks of 3M Corporation.This product is made with Intelli-Gel ®* polymeric columned material and Gelastic™* polymeric columned material.*EdiZONE, LLC of Alpine, UT.Patent Information:This product is covered by one or more of the following US patents: 7666341, 7076822, 7060213, 6843873, 6797765, 6767621, 6447865, 6413458, 6099951, 6026527, 5749111 and other US and/or foreign patents and pending patent applications.P/N 101392000 Rev A 6/10。

床垫七区一体设计理念

床垫七区一体设计理念

床垫七区一体设计理念
床垫是我们日常生活中必不可少的物品,对于一个好的睡眠质量来说,选择一
款合适的床垫至关重要。

近年来,床垫七区一体设计理念逐渐受到人们的关注和青睐。

这一设计理念将床垫分为七个不同的区域,分别为头部、颈部、肩部、腰部、臀部、腿部和脚部,每个区域都有特定的支撑和舒适度,以满足人体各部位的需求。

首先,头部区域的设计注重对头部的支撑和舒适度,能够有效缓解头部的压力,让人在睡眠中更加放松。

颈部区域的设计则能够提供良好的颈部支撑,有效缓解颈部的疲劳和不适。

肩部区域的设计能够减轻肩部的压力,让人在睡眠中不易出现肩部酸痛的情况。

腰部区域的设计注重对腰部的支撑和舒适度,能够有效缓解腰部的不适感。

臀部区域的设计能够提供合适的支撑和舒适度,有效缓解臀部的压力。

腿部区域的设计注重对腿部的支撑和舒适度,能够有效缓解腿部的疲劳感。

最后,脚部区域的设计能够提供合适的支撑和舒适度,有效缓解脚部的不适感。

床垫七区一体设计理念的出现,让人们在选择床垫时更加注重人体工程学和睡
眠健康,能够更好地适应人体各部位的需求,提供更加舒适的睡眠体验。

同时,这一设计理念也引导了床垫行业的发展方向,推动了床垫产品的不断创新和提升。

相信随着科技的不断进步和人们对睡眠健康的重视,床垫七区一体设计理念将会在未来得到更加广泛的应用和推广。

Arjo EVOLVE 非电动床垫系列产品说明书

Arjo EVOLVE 非电动床垫系列产品说明书

FOR THE PREVENTION AND TREATMENT OF STAGE I-IV PRESSURE ULCERSRAISING THE STANDARDOF CAREWith over 50 years experience, at ArjoHuntleigh we are dedicated to creating safe and efficient care environments where there is a minimal risk of injury to both caregivers and patients.Our solutions have continually raised the standard of dignified care around the world while improving patient outcomes. Our range of therapeutic mattress systems are specifically designed to prevent and treat pressure ulcers with patient comfort in mind.PRESSURE ULCERS:THE GLOBAL CHALLENGE Pressure ulcers present a global challenge to healthcare providers, draining valuable resources and causing unnecessary suffering to patients and residents.Risk factors that can lead to pressure ulcers include:• Immobility• Pressure• Moisture• Temperature• Shear and FrictionBy addressing these concerns and applying the appropriate solutions and protocols, pressure ulcers in care environments can be successfully prevented and treated.Stage I Stage II Stage III Stage IVPressure ulcers are graded from stage I to stage IV, categorizing the wound from non-blanchable redness over a bony prominence to full skin loss and the destruction of tendon and bone.FACT:According to the NPUAP, 15% of all patients will develop a pressureulcer in an acute care environmentSource: Amlung S, et al. The 1999 National Pressure Ulcer Prevalence Survey: A BenchmarkingApproach. Advances in Skin & Wound Care. 2001; 14(6): 297-301.INTRODUCING PRESSURE IQ EVOLVE™:FOR THE EFFECTIVE PREVENTION AND TREATMENT OF S Pressure IQ Evolve™ is the non-powered therapeutic mattress replacement system (MRS), specifically designed forthe prevention and treatment of stage I-IV pressure ulcers. With innovative features such as the 45 Helix pods, thePressure IQ Evolve™ provides uninterrupted preventative and therapeutic care in all care settings.With minimal maintenance requirements and a low cost of ownership, the Pressure IQ Evolve™ is the cost effectiveand versatile care solution.45 Helix Pods• I nnovative design provides a coil of airfor dynamic pressure redistribution• Enhanced conformability and immersionSelf-Adjusting Technology™T OF STAGE I-IV PRESSURE ULCERSHigh Density Perimeter Foam3" Hybrid Topper FoamMulti-Way Stretch Cover• I mproved stability at the edge of the patient surface • 5° sloped foot section for effective heel offloading• C ombined high quality visco- elastic and polyurethane foams • I mproved patient comfort and immersion • I mproved resilience to wear and tear• A durable stain resistant and washable 4-way stretch fabricThe non-powered revolutionary design of Pressure IQ Evolve ™ offers uninterrupted therapy, helping to improve patient outcomes while reducing unnecessary cost.The innovative combination of Self Adjusting Technology (SAT) and Helix Pods in the Pressure IQ Evolve ™ provides:• Pressure redistribution equivalent to low air loss (LAL) mattresses • Immersion equivalent to LAL mattresses • Envelopment equivalent to LAL mattresses • T he solution, superior to LAL mattresses, that addresses the five factors of pressure ulcer development when combined with Skin IQ™ Microclimate Manager (MCM)*EVOLUTIONARY DESIGNREVOLUTIONARY PERFORMANCEPRESSURE IQ EVOLVE ™LAL MATTRESSRepresentative pressure mapping images of a testing done on a supine male 71 inches (1.8 meters) tall weighing 190 lbs (86.2 kg)• Low 1/4" (6.35mm) profile may support fall prevention initiativessurface reduces friction and shear, minimising the risk of pressure ulceration • Helps improve comfort; controls odor; silent operationPRODUCT SPECIFICATIONSPRESSURE IQ EVOLVE™Product SpecificationsMattress Length76-84 in (193.04-213.36 cm)Mattress Width32-38 in (81.28-96.52 cm)Mattress Height8 in (20.32 cm)Mattress Weight36 lb (16.33 kg)Maximum Patient Weight500 lbs (227 kg)Anti-microbial: Inherent in both the cover and foamOrder Number DescriptionPIQ-EV-DPNB-(SIZE)-NAVY Pressure IQ Evolve MRS; Navy Top, Non-Skid BottomPIQ-EV-DPNB-3580-NAVY Pressure IQ Evolve MRS; Navy Top, Non-Skid Bottom 35 x 80”PIQ-EV-DPNB-3584-NAVY Pressure IQ Evolve MRS; Navy Top, Non-Skid Bottom 35 x 84”PIQC-EV-DPNB-(SIZE)-NAVY Replacement Cover; Navy Top, Non-Skid BottomPIQC-EV-DPNB-3580-NAVY Replacement Cover; Navy Top, Non-Skid Bottom 35 x 80”PIQC-EV-DPNB-3584-NAVY Replacement Cover; Navy Top, Non-Skid Bottom 35 x 84”PIQ-EV-SAT Replacement SAT SystemPIQ-EV-FS-(SIZE) Replacement Foam Shell413657 User Manual User ManualOther options or sizes may be available. Please check with your ArjoHuntleigh representative.DescriptionSkin IQ™ MCMOrder NumberSIQCPST04US Coverlet complete kit, 4/caseSIQCOST04UN Coverlet only, 4/caseSIQPSST04UC Coverlet power supply, 4/caseSIQCPSTS1US Coverlet complete kit, eachSIQCOSTS1UN Coverlet only, each。

床垫七区一体设计理念

床垫七区一体设计理念

床垫七区一体设计理念
床垫是我们每天睡眠的伴侣,对于我们的健康和舒适度至关重要。

随着科技的
发展和人们对健康的重视,床垫的设计也在不断创新。

其中,床垫七区一体设计理念成为了近年来备受关注的话题。

床垫七区一体设计理念是指将床垫分为七个不同的区域,分别是头部、颈部、
肩部、背部、腰部、臀部和腿部。

每个区域都有特定的支撑和压力分布设计,以满足人体不同部位的需求。

这种设计理念旨在让人们在睡眠时能够得到更好的支撑和舒适度,从而改善睡眠质量,减少身体疲劳和疼痛。

首先,头部区域的设计要考虑到颈椎的支撑和舒适度,以避免颈部疼痛和僵硬。

其次,肩部和背部区域需要有足够的支撑,以保持脊椎的自然曲线,减少背部疼痛和压力。

腰部区域则需要更多的支撑和压力分散,以避免腰部受压造成的不适感。

臀部和腿部区域则需要更多的柔软度和舒适度,以保持身体的放松和舒适。

床垫七区一体设计理念不仅考虑到了人体各部位的需求,还能够根据个人的体
型和睡姿进行个性化的支撑和舒适度调整。

这种设计理念的床垫不仅能够提供更好的睡眠体验,还能够减少身体疲劳和疼痛,对于保护人体健康具有重要意义。

在选择床垫时,我们可以更多地关注床垫的设计理念和技术,以确保我们能够
得到更好的睡眠体验。

床垫七区一体设计理念的床垫不仅是一种产品,更是对人体健康的关爱和呵护。

让我们在享受舒适睡眠的同时,也能够保护好自己的健康。

SleepSafe 床垫说明书

SleepSafe 床垫说明书

good night.sleep safe.Your Checklist for Preparing to Order the Correct SleepSafe ® BedWhen ordering your SleepSafe® Bed, please select the following choices:1. Rail Height: O LOW O MEDIUM O TALL O BASIC (Product has limitations)2. Foundation: O FIXED with Box Spring O FIXED with Bunkie Board O ARTICULATED O HI-LOO MANUAL _Full HiLo _HiLo Only _Articulation Only _ Electric Articulation / Manual HiLo 3. Finish: O OAK O MAPLE O CHERRY O MAHOGANY O ALDERO SOLID COLOR __White __Blue __Green __Red __Yellow __Orange __Purple __Pink __BlackO MULTI COLOR (Please call for a form to select your color combination.) 4. Bed Size: O TWIN O FULL O QUEEN5. Padding: O PADDING AROUND WINDOWS O PADDING OVER WINDOWS O NO PADDINGPADDING COLOR __Cream __Gray __Light Blue __Taupe6. Windows: O CLEAR WINDOWS O MESH WINDOWS O CLEAR/MESH COMBINATION7. Extras: O HEADBOARD WINDOW O FOOTBOARD WINDOWO IV POLE KIT O TUBING CHANNEL ACCESS O DUAL VIEW (Tall Bed)O SleepSafer® EXTENSION O SleepSafer® EXTENSION with ENCLOSURE3629 Reed Creek Drive · Bassett, VA 24055 · Local: 276-627-0088 · Fax: 276-627-0234All SleepSafe® Beds include these items:• Bed Enclosure• Foundation• Premium Mattress • Casters• Assembly Instructions • Tools for Assembly• Standard Shipping Within the Continental US Made in USASafety FirstTHREE MODELS of SleepSafe ® Beds are available in TWIN, FULL and QUEEN sizes with safety rail height protection ranging from 8¾” to 36¼” above the mattress depending on the foundation. Appropriate SAFETY RAIL HEIGHT is based on the activity level of the user, with more active users requiring additional height.SleepSafe® Beds are a proven, ultra-safe solution to address problems with entrapment and falls. Unique in the industry, these beds meet or exceed FDA guidelines on the 7 Zones of Entrapment .SleepSafe® II Medium Bed with Alder finishPremium Memory Foam MattressSleepSafe® Beds use CertiPUR-US ® compliant foam products for our mattresses featuring gel technology. They provide optimized pressure redistribution, rapid heat dissipation, and increases in breathability compared to standard foam. Mattresses support up to 350 pounds. Full details are available on our website.Resists BurrowingThe SleepSafe ® precision-fi t custom mattress fi ts tightly within the bed frame. Even with aggressive compression, it is diffi cult to burrow deeply enough to create an entrapment issue or safety hazard.Clear, break-resistant windows, or our new Please consider the TRANSFER HEIGHT before ordering your bed. It is the distance from the topof the side panel (below the safety rail) to the fl oor. SleepSafe® - LOW - 18½” or 20” Transfer Height SleepSafe® II - MEDIUM - 29½” or 31” Transfer Height SleepSafer® - TALL - 23½” or 25” Transfer Height Easily MovedCasters provide mobilityand can be locked.Safest Yet!SleepSafer® Extension Kit increases bed safety height another 16¾”. The Kit, with or without top enclosure, may be included with a new bed order or can be sent as a retrofi t for most existing beds. Screen mesh windows off er additional ventilation.SleepSafer®SleepSafe® II SleepSafe®Safety Rail Heights – 3 ModelsLOW – This is our classic SleepSafe® bed with safety rails ranging up to 17¼” above the mattress depending on the foundation choice.MEDIUM – The SleepSafe® II provides protection ranging up to 27” above the mattress depending on the foundation choice.TALL – The SleepSafer® provides protection up to 36¼” above the mattress depending on the foundation choice. The SleepSafer® Extension Kit off ers an additional 16¾” of safety rail height when ordered or retrofi tted to your existing SleepSafer® Bed.50¾”57”MEDIUM TALL40¾”SleepSafe® BedSpecifi cationsLow BedSleepSafe®Medium Bed SleepSafe® IITall Bed / ExtensionSleepSafer®SAFETY RAIL HEIGHT Distance from the top of mattress to the top of the safety railFixed Foundation with Box Spring (Choice of settings)12” or 8¾” 17¾”, 14” or 10”31” or 24¾” / 47¾” or 41½” Fixed Foundation with Bunkie Board (Choice of settings)17¼” or 14” 27” or 21¾”36¼” or 30” / 53” or 46¾” Manual Articulating Foundation 15” or 11¾”21”, 17” or 13¼”34” or 27¾” / 50¾” or 44½” Manual HI-LO FoundationLO 11½” to EVEN with rail LO 21¼” to HI 9½” or LO 16” to HI 4¼”LO 30½” to HI 18¾” / LO 47½” to HI 35¾”Articulating Foundation (Choice of settings)15” or 11¾”21”, 17” or 13¼”34” or 27¾” / 50¾ or 44½”Electric HI-LO Foundation (LO to HI Settings)LO 11½” to HI 1¼” below rail LO 21¼” to HI 11” or LO 16” to HI 5¾” LO 30½” to HI 20¾” / LO 47½” to HI 37¼”MATTRESS HEIGHT Distance from the top of the mattress to the fl oor.Fixed Foundation with Box Spring (Choice of settings)23¾” or 27” 28”, 32” or 35½”23¾” or 30”Fixed Foundation with Bunkie Board (Choice of settings)18½” or 21¾”18¾” or 24”18½” or 24¾”Manual Articulating Foundation 20¾” or 24”25”, 28¾” or 32½”20¾” or 27”Manual HI-LO FoundationLO 24¼” to HI 36” LO 24½” to HI 36¼” or LO 29¾” to HI 41½”LO 24¼” to HI 36” Articulated Foundation (Choice of settings)20¾” or 24”25”, 28¾ or 32½”20¾” or 27”Electric HI-LO Foundation - (LO to HI Settings)LO 24¼” to HI 34½” LO 24½” to HI 34¾” or LO 29¾” to HI 40” LO 24¼” to HI 34½”FLOOR TO RAIL HEIGHTDistance from the top of the rail to the fl oor.35¾”45¾”54¾” / 72”OVERALL OUTSIDE DIMENSIONSTwin 42¼” W x 80½” L x 40¾”H 42¼” W x 80½” L x 50¾”H 42¼” W x 80¼” L x 56”H (72¾”H w/Ext.)Full 56” W x 80” L x 40¾”H 56” W x 80” L x 50¾”H 56” W x 80” L x 57”H (72¾”H w/Ext.)Queen65” W x 80” L x 40¾”H 65” W x 80” L x 50¾”H 65” W x 80” L x 57”H (72¾”H w/Ext.)MATTRESS SIZE Width without pads / Width with pads / LengthTwin 38” W / 36” W / 77” L 38” W / 36” W / 77” L 38” W / 36” W / 77” L Full 51” W / 50” W / 77” L 51” W / 50” W / 77” L 51” W / 50” W / 77” L Queen61” W / 60” W / 77” L 61” W / 60” W / 77” L 61” W / 60” W / 77” L UNDER BED FLOOR CLEARANCEStandard Models8”8”7¾”TRANSFER HEIGHT Distance from the topedge of the folded down safety rail to the fl oor.22¼” with Safety Rail On20¾” with Safety Rail Off32” with Safety Rail On30½” with Safety Rail Off26” with Safety Rail On24½” with Safety Rail Off72¾” w/Extension7/17HI -L O FO UN DA TI ONAll ow s c on tro l o f th e fra me he igh t a s w ell as th e h ea d a nd kn ee el ev ati on .Sle ep Sa fe® II sh ow n h ere wi th ou t th e m att res s.FoundationsFIXED – The mattress rests on a fi xed foundation, which can be a box spring or bunkie board, depending on the safety rail protection needed. A bunkie board allows 6” of addtional safety rail height.MANUAL – Off ers four NON-ELECTRIC options: Full HiLo Manual, Manual Hi-Lo only, Manual articulation only, and Electric articulation with Manual Hi-Lo. Cranks are located in front, below the safety rail.ARTICULATED – The mattress rests on an ELECTRIC frame that has both head and knee articulation, operated by a handheld remote. HI-LO – The mattress rests on an ELECTRIC frame that off ers mattress height adjustability as well as head and knee articulation. The surface of the mattress can be adjusted from 22¾” to 38¾” from the floor.AccessoriesDUAL VIEW SAFETY RAILS For more visibility or accessibility, our SleepSafer® TALL bed may be ordered with see-through rails on both sides.SLEEPSAFER® EXTENSION KIT increases bed safety height another 16¾”. The kit, with or without top enclosure, may be included with a new bed order or can be sent as a retrofi t for most existing beds.PADDINGCustom-fi t padding provides protection from contact with the bed frame. The 3/4” high-density foam is covered with easy to clean waterproof nylon. Pads can be ordered to surround the windows or cover the windows. They can be removed for cleaning. IMPORTANT: When required, padding needs to be indicated at the time of ordering your bed. IV ATTACHMENT KIT A stainless steel IV pole, along with an access area, may be orderedwith your bed.SleepSafe II Medium Bedwith Alder FinishBreak-resistant windows are availablefor the headboard and/or footboard.Finish ChoicesSleepSafe® Beds can be fi nished using one of these choices:SOLID COLORSBright, highly durable surfaces off er a suitable option for matching any decor. Colors: White, Blue, Green, Red, Yellow,Orange, Purple, Pink and Black.OAKMAPLECHERRYMULTICOLOR MIX & MATCHYou can mix and match the colors for a truly unique bed. Please call for details!SleepSafe II Medium Bed with Oak FinishMAHOGANYALDER12 34FDA RegisteredSleepSafe® II - Medium Bed Full Size - CherryThe New SleepSafe ® Manual Safety Bed.RETHINKING THE WAY SAFETY BEDS CAN WORK.Manual Foundation no w offers four choices with easy to operate hand cranks.UP FRONT CONTROL AND VERSATILITY.CONTROLS KNEE ELEVATION1) Manual Hi-Lo - Hi-Lo Foundation with Articulation.This will raise and lower the mattress height and raise and lower the head and knee section of the bed by using the three cranks.2) Manual Flat - Hi-Lo Foundation without Articulation.This will raise and lower the mattress height by using one crank located in the center of the front panel of the bed.3) Manual Electric - Articulating Foundation with Manual Hi-Lo. This will raise and lower the head and/or knee section of the bed electrically with remote. Will raise and lower mattress manually.4) Manual Plus - Articulating Foundation without Hi-Lo.This will raise and lower the head and/or knee section of the bed by using two cranks located in the front panel of the bed.SleepSafe® Beds is a domestic USA manufacturer of custom safety beds, featuring removable safety side rails, designed to address the issues of falls and entrapment for those with special needs. Models include SleepSafe®-Low Bed, SleepSafe® II- Medium Bed, and SleepSafer®- Tall Bed , offering progressively more safety rail to mattress height.SleepSafe® Beds are built to order, offering twin, full or queen size; fixed, articulating or HiLo foundations; padding; wood and color choices, and other helpful options. SleepSafe® Beds help those with special needs get a safe, restful sleep with peace of mind for their caregivers.CONTROLS HEAD ELEVATIONCONTROLS MATTRESS HEIGHTFDA RegisteredWe’re here to help.SleepSafe® Beds is a domestic USA manufacturer of custom safety beds, featuring removable safety side rails, designed to address the issues of falls and entrapment for those with special needs. Models include SleepSafe®-Low Bed, SleepSafe® II- Medium Bed, and SleepSafer®- Tall Bed, offering progressively more safety rail to mattress height.SleepSafe® Beds are built to order, offering twin, full or queen size; fixed, articulating or HiLo foundations; padding; various finishes, and other helpful options.SleepSafe® Beds help those with special needs get a safe, restful sleep with peace of mind for their caregivers.SleepSafe II® - Medium Bed - Alder - Both Safety Rails Up- Manual Crank for HiLo control of mattress height - 31.5” Transfer HeightSleepSafe II® - Medium Bed - Multi-Color (Customer’s Choice)- Both Safety Rails Up - 31.5” Transfer HeightSleepSafer®- Tall Bed - Cherry - Shows Extension and Top- Extension Adds 16.75” to Safety Rail Height - Shows optional screened mesh windows - Extension may be ordered with or without Top.- Safety Rail Flip Open Option is Available - 25.5” Transfer HeightSleepSafe® - BASIC Bed - Maple - One Safety Rail Up, One Down - Bunkie Board Fixed Foundation - 21.25” Transfer HeightSleepSafe® - Low Bed - Oak - One Safety Rail Up, One Down- Manual Crank for Head and Knee Articulation - Screened Mesh WindowsSleepSafe II® - Medium Bed - Oak - Padding surrounding clear windows - IV Pole with Medical Tubing Access - One Safety Rail Up, One Down - 31.5” Transfer Height。

床垫分层说明

床垫分层说明

第一层:表面刺绣层第二层:高级皮革层第三层:精编定型网布第四层:玉功能层第五层:复合碳布层第六层:有害电磁波屏蔽层(需定制)第七层:耐高温保护层第八层:加热线发热层第九层:温度控制层第十层:生态无纺布第十一层:高温隔热层第十二层:环保生态棉层第十三层:盖布(需定制)第一层:表面刺绣层彰显品牌第二层:高级皮革层尽显高贵大方,脱俗典雅,面料手感温柔舒适,弹性和透气性俱佳。

第三层:精编定型网布用于玉石的固定与美化。

第四层:玉功能层由天然玉石镶嵌而成,玉石有多种功能,补充微量元素,提高人体免疫力,抑菌,除螨,负离子,热灸,远红外线等皆由此层发出。

第五层:复合碳布层由多种重要成份、精选竹炭粉末、高密度优势海绵组成的碳棉层,经高温、高压杀菌后压合成垫体,有独特的吸湿、透气、拉力强、耐磨擦、弹性好、防寒防潮等。

第六层:有害电磁波屏蔽层采用进口屏蔽布有效阻断有害电磁波和地下水脉波。

能均匀散热与屏。

第七层:耐高温保护层具有抗老化,抗折阻燃的性能。

第八层:加热线发热层均衡加热第九层:温度控制层具有自动调节温度达到恒温,人性化的设计,有效组织电阻负荷过大安全可靠。

第十层:生态无纺布具有很好的保温防潮与导热的性能,同时可以防止电热线相互缠绕。

第十一层:高温隔热层用于隔热,保护人体。

第十二层:环保生态棉层能有效把人体压力化解为零,抵消反动力,为您提供最平均、最真实的支撑使身体时间接触的部位处于无压力状态,不阻碍血液循环及不易产生疲劳和酸痛,因而减少睡眠不必要的翻身次数。

对于失眠、易落枕、颈椎病患者及孕妇适用、具有轻、薄、暖、透气、透湿的特性。

第十三层:盖布(需定制)美观大方、保护床垫。

华氏舒适性床床垫用户指南书说明书

华氏舒适性床床垫用户指南书说明书

Instructions of Use Standard High EasySling Application in Chair:With sling label facing outwards glide sling down back of patient.Take the leg sections of the sling and place them down each side of the patient.Fold the sling in half with the label inside the sling. Turn patient on their side and place folded edge of the sling against spine areaOpen sling out and lay half over the patient then roll up the other half of the sling underneath against the spine area. Thread leg section under the leg.11223Sling Application on Bed:Glide each leg section under each thigh. Ensure that the leg sections are not twisted. Connect leg straps together by taking the right leg strap and thread through the modesty loop.3Roll patient onto the opposite side and pull through the underside of the sling. Lay patient flat on their back and position central to the sling.With the leg straps threaded through the modesty loop, attach the straps to the lower stud on the spreader bar. When securing the clips there should be a click sound to confirm the clip is located correctly.Fit the shoulder strap clips to the spreader bar. As before when securing the clips there should be a click sound to confirm the clip is located correctly. Once you are happy that the sling is fitted correctly you can now commence the transfer.NOTE: Once the sling takes the weight of the patient you may need to re-adjust the position of the sling for the patients comfort. Lower the patient back onto the chair/bed to make any adjustments before continuing the transfer.Ensure the leg sections are brought together bythreading the leg paddle through the modesty strap. This gives a closed leg position.Once the sling has been fitted correctly to your patient, attach the loop straps to the spreader bar of the lift. Color coding on the pick up loops are provided for ease of reference and position. You can now commence the transfer.NOTE: Once the sling takes the weight of the patient you may need to re-adjust the position of the sling for the patients comfort. Lower the patient back onto the chair/bed to make any adjustments before continuing the transfer.2211Attaching a Clip Sling: (stud spreader bar)Attaching a Loop Sling: (loop spreader bar)General Instructions: WarningDo not attempt to transfer the patient untilall appropriate sling attachments are secured to the lift spreader bar and you are satisfied that the sling is the correct style, size and fit for the patient. Correct sizing of a sling is important as a sling that is too large could cause the patient to slip through the aperture.While every attempt is made to instruct a safe move you must conform to the current moving and handling procedures/regulations. If in any doubt, consult your Moving and Handling Advisor.Service Label & Sling Checks:All products should be checked each time they are used for any signs of deterioration.The service label is a visual guide to the product’s check. Please conduct a thorough sling check in line with current safety requirements in your country.If in doubt consult your distributor for current sling checking protocols.A risk assessment must be carried out to ensure that the correct size and style of sling has been met before use.Pre-use sling check list:• braiding/straps for deterioration and fraying• material for holes/snagging• compatibility with the lift• safe working load of both the lift and sling/ product (if applicable)• label is legibleRemove from use immediately if there are any signs of deterioration to the sling or straps or the labelis illegible.Washing Guidelines:• Follow laundry temperatures for washing and drying detailed on the product label.• Always ensure that all Hook & Loop fastenings are fully closed before washing.• All products should be laundered using non- biological detergents.• DO NOT IRONProduct Care:• Ensure that any Hook & Loop fastenings are closed when not in use. This will prevent unnecessary snagging of the sling material and prevent clogging of the Hook & Loop.• Launder regularly.• Store products in a suitable dry clean place.• Silvalea will accept no liability for any additions/ adaptations made to our products that have NOT been carried out by ourselves. Doing so may cause serious injury or death to the patient.Drying Guidelines:• Follow the recommended drying temperaturesas stated on product label.• Overheating a textile product can cause deterioration in the material components.• Do not place the product on a convector heateror steam pipes.。

Invacare Reliant和Premier Series患者搬运床床垫说明书

Invacare Reliant和Premier Series患者搬运床床垫说明书

I n va c a r e®S l I n g SInvacare offers a complete line of slings to meet the dynamic needs in both the long-term care and homecare settings. Invacare® Reliant™ Series Slings are an industry standard and deliver the ease of use, comfort and security that is standard in all Invacare Products. The Invacare® Premier Series Slings offer additional fabric and style options to meet a wider array of needs, as well as value-adding features for the caregiver and patient alike.Complete instructions for lift usage and sling procedures are found in the Invacare Operating Manual. Only Invacare slings and accessories should be used on Invacare lifts.Invacare ® Reliant ™ Slings come in an array of styles to meet a variety of client needs. Reliant slings feature a unique, fully padded fabric that forms a soft yet supportive surface. The soft, brushed lining helps prevent sliding for ultimate comfort and skin protection, and the stretch-resistant feature helps the slings hold their shape for superior support and ease of positioning. For clients and caregivers alike, Invacare Reliant slings are designed with comfort and safety in mind.FeaturesSling size and fit can vary significantly depending on patient weight and girth. These are general guidelines. Consult physician before sling selection.Washing instructions are on each sling label. Washing temperatures should not exceed 180˚ F. Air-dry or dry at low temperatures.All slings are constructed of polyester fabrics which can be used in wet or dry environments.All Invacare ® slings were designed specifically for use with Invacare ® brand lifts for proper usage andoptimal performance. To receive the maximum benefits from Invacare products, please see the size guide, product specs and operator manuals for solutions that best suit your needs.Invacare ® Reliant ™ Full-Body Slings Invacare ® Reliant ™ Full-Body Slings with Commode Opening Invacare ® Reliant ™ Full-Body Slings with Commode Opening Invacare ® Reliant ™ Toileting Sling with Belt1.3.4.2.3412Full Body Sling With/Without Commode Opening (CO)An easy sling to use while transferring the patient from the bed to a wheelchair, toilet or shower chair or from floor to bed. It offers total head and neck support and the padded lower section provides additional under-thigh comfort and support. Use the full body sling for patients who are totally dependent, partially-dependent, non-weight bearing, very heavy or have limited head control. Use this sling for amputee patients (in a reclined position).Compatible with the following lifts: Invacare ® I-Lift ® Series Lifts Invacare ® I-Transia ® Ceiling Hoist Invacare ® Reliant ™ 450, 600 Lifts Divided Leg SlingThe divided leg sling is a secure, easy-to fit general purpose sling, designed for the majorityof sling users. Use the divided leg sling for patients who are totally dependent, partiallydependent, non-weight bearing, very heavy or have limited head control. Use this sling when transferring the patient from the bed to a wheelchair, recliner or shower chair.The large opening also accommodates patible with the following lifts: Invacare ® I-Lift ® Series LiftsInvacare ® I-Transia ® Ceiling Hoist Invacare ® Reliant ™ 450, 600 Lifts SIZE A B C D E Weight Model #/MaterialCapacityM 41.5" 53.3" 23.9" N/A 43.7" 450 lb. R110/M esh L 45.5" 58.3" 26.3" N/A 47.7" 450 lb. R111/M esh XXL 45" 55" 45" N/A 45" 600 lb. R140/M esh M 41.5" 53.3" 23.9" 6" 43.7" 450 lb. R114/M esh w/CO L 45.5" 58.3" 26.3" 7" 47.7" 450 lb. R115/M esh w/CO XL 45.5" 63.2" 26.3" 7" 47.7" 450 lb. R116/M esh w/CO XXL 45" 55" 45" 7" 45" 600 lb. R141/ Mesh w/CO M 41.5" 54.7" 23.2" N/A 41.8" 450 lb. R112/Solid FabricL 45.5" 60.3" 26.3" N/A 45" 450 lb. R113/Solid Fabric XL45.5"65.3"26.1"N/A45"450 lb.R117/Solid FabricSIZE A B C Weight Model # CapacityS 33" 29.16" 12" 450 lb. R100P M 37.5" 35.66" 17" 450 lb. R100L 41"40.66" 20.5"450 lb.R101XL44.5" 43.16" 22.6" 450 lb. R102ACEBA CBDW e i g h t i n P o u n d sGeneral Sling Sizes*Color/Weight ChartS M L XL XXLNavy Purple Green Blue Black*Color/weight chart is intended as a guideSolid Fabric Toileting SlingThe Toileting Sling offers superb access for quick toileting and hygiene. It is easy to place and remove in a bed or chair situation. The fully padded design supports the back, offers under thigh comfort and allows for removal of clothing. Color coded positioning straps help align the sling properly on the hanger bar. Note: This sling requires the patient to have FULL head and neck control.Compatible with the following lifts: Invacare ® I-Lift ® Series Lifts Invacare ® I-Transia ® Ceiling Hoist Invacare ® Reliant ™ 450, 600 Lifts SIZE A B C Weight Model # Capacity L36"44.7"20.5"450 lb.R121A BCTransfer Sling (use with Stand-Up Lift)Transport slings are for transferring patients with minimal weight-bearing capacity, whohave head and neck control, are cooperative, can sit up on the edge of the bed (with or without assistance) and are able to bend at the hips, knees and ankles. Use the R134 and R136 transport sling for transferring patient from bed to chair, chair to car or general in-room transport. Do not raise patient to a full standing position while using the transport patible with the following lifts:Invacare ® Reliant ™ 350 Lift Invacare ® Get-U-Up ™ Lift A CBSIZE A B C Weight Model # Capacity One Size 34"13.5"9"440 lb.R134XL46" 13.5" 10" 440 lb. R136Standing Sling (use with Stand-Up Lift)Standing slings are for patients who are partially dependent, have at least 60% weight bearing capacity, have head and neck control, are cooperative, can sit up on the edge of the bed (with or without assistance) and are able to bend at the hip, knees and ankles. Use the R130 or R131 standing slings for standing assistance, quick toileting, weight bearing practice and for transferring patient from bed to chair, or chair to patible with the following lifts:Invacare ® Reliant ™ 350 Lift Invacare ® Get-U-Up ™ Lift A BSIZE A B Weight Model # Capacity One Size 60"16"440 lb.R130XL84" 16" 440 lb. R131Stand Assist SlingDesigned for use with the Invacarestand up lifts, the Stand Assist Sling offers a comfortable and safe transfer for those who have some weight bearing ability, but cannot standindependently. The sling is well-padded and features non-slip material on the side that touches the patient to assure a comfortable transfer patible with the following lifts:Invacare ® Roze ™ Lift Invacare ® Reliant ™ 350 Lift Invacare ® Get-U-Up ™ Lift Transfer Stand Assist SlingAlso designed for optimal use with the Invacare stand up lifts, this high-quality sling provides simple seated transfer for patients with minimal weight bearing ability.Compatible with the following lifts:Invacare ® Roze ™ Lift Invacare ® Reliant ™ 350 Lift Invacare ® Get-U-Up ™ LiftThe Invacare ® Premier Series Slings balance solutions for any transfer. Invacare says this with confidence because these slings were developed in collaboration with Occupational and Physical therapists. Invacare Premier slings are available in a wide variety of styles and can be adjusted to ensure a comfortable and secure fit for the patient. Clearly labeled slings and easy attachment points make it simple for the caregiver to quickly attach the sling and lift the patient.CBABCABMo d el #/Material SIZE A B C Waist Weight Polyester Fabric Capacity S 10.2" 33.1" 34.7" 46.4" 450 lb. 2484685M 13.0" 35.3" 46.1"55.1"450 lb. 2484686L 14.2" 37.4" 50.0" 59.1" 450 lb. 2484687XL14.2"40.2"71.3" 80.3"450 lb.2484688Model #/MaterialSIZE A B C Waist Weight Polyester Fabric Capacity S 33.9" 33.1" 9.5" 46.4" 450 lb. 2484689M 40.2" 35.3" 10.2" 55.1" 450 lb. 2484690L 46.5" 37.4" 13.0" 59.1" 450 lb. 2484691XL48.5" 40.2" 13.8" 80.3" 450 lb. 2485117D。

Accora 400 600床垫说明书

Accora 400 600床垫说明书

IntroductionDEALER: These instructions MUST be given to the user of the product.USER: BEFORE using this product, read this manual and save for the future reference. GeneralSignal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the information below for definitions of the signal words.WARNING: Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.CAUTION: Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or both. Product DescriptionThe Accora 400 and 600 mattresses are multi-tiered pressure redistribution mattresses with high density head / torso sections. The mattress incorporates an air channel heel section, firm mattress edges and a 4 way stretch top cover. Clinical ApplicationsAccora 400 is indicated for users up to 350 lbs. Accora 600 is indicated for users up to 450 lbs. Suitability for the mattress must be assessed by a competent practitioner.Instructions for use1. Remove all packaging.2. Lay the mattress onto the bed frame, ensuringthere are no sharp edges which may tear the cover.3. Do not use the mattress without a cover as itprovides a protective barrier which helpsextend the life of the product. 4. Ensure the mattress is orientated with the silkscreen text facing upwards and the feetgraphic at the foot end of the bed. DecontaminationTo clean the mattress1. Remove all bedding.2. Clean the top and bottom covers with anorganic cleaner or soapy water.3. Wipe down the mattress unit with a dampcloth, pre-soaked with warm water containinga mild detergent. Approved intermediate leveldisinfectants may be used according to thecover material.4. After cleaning, please avoid dust andproximity to dusty areas. All parts should beair dried thoroughly before use.IFU-FM1-001EN REV 03IFU-FM1-001EN REV 03 MaintenanceInspectionThe internal and external parts for the mattress must be inspected at least every 3 months for damage and wear. Remove the mattress from service and replace all damaged parts. Inspection RecordAn inspection record should be kept recording the Inspection date, Name of Inspector, Whetherdamage found, Date removed from service, repair date, returned to service date. Compression Test1. Remove the bedding from the mattress.2. Measure the thickness of the mattress(mattress depth) in an uncompressed area. 3. Lay a straight edge over the compressed areaof the mattress. Measure the depth of the compressed area (compression depth). 4. Use the following formula to determine theamount of compression (compress percentage):DisposalDisposal of the mattresses should be inaccordance with local regulations and facility standard operating procedures.Limited WarrantyThis warranty is extended only to the original purchaser/user of our products.This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Accora warrants the mattress and cover when purchased new and unused to be free from defects in materials,workmanship, and assembly for the following time periods:If within such warranty period any such product shall be proven to be defective, such product shall be repaired orreplaced with new or refurbished product components, or are fund corresponding to the proper service time shall be offered, at Accora option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. Moreover, the warranty period of their paired or replaced product shall terminate with the termination of the warranty period for the original product component.For warranty service, please contact the dealer from whom you purchased your Accora product. In the event you do not receive satisfactory warranty service, please write directly to Accora at the address on the back cover. Provide the dealer’s name, address, model number, and the date of purchase, indicate nature of the defect and, if the product is serialized, indicate the serial number.Accora will issue a return authorization. The defective unit or parts shall be cleaned using disinfectant prior to return and must be returned for warranty inspection using the serial number, when applicable, as identification within thirty days of return authorization date. DO NOT return products to our factory without our prior consent. C.O.D. shipments will be refused; please prepay shipping charges.LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE; DAMAGE CAUSED BY ANY EVENTS OUTSIDE THE CONTROL OF ACCORA INCLUDING, BUT NOT LIMITED TO: DAMAGE FROM CARELESSNESS, ACCIDENTAL DAMAGE, DAMAGE FROM SHARP OBJECTS, TEARS, NEGLIGENCE (WHETHER WILLFUL OR NOT), TAMPERING, DAMAGE FROM FIRE, DAMAGE OCCURRING IN TRANSIT AFTER DELIVERY BY ACCORA OR EXCESSIVE WEAR AND TEAR, INCLUDING BUT NOT LIMITED TO THE FAILURE TO FOLLOW CLEANING INSTRUCTIONS, USE OF INAPPROPRIATE CLEANING COMPOUNDS AND FAILURE TO ENSURE THAT ANY PRODUCT IS THOROUGHLY DRIED BEFORE TURNING OR FLIPPING IT OVER; DAMAGE RESULTING FROM CONTAMINATION FOLLOWING DAMAGE TO THE COVER AND FAILURE TO REPLACE IT, CONTAMINATION DUE TO INCORRECT STORAGE OR FAILURE TO INSPECT THE INTERIOR OF THE PRODUCT AS STATED HEREIN, OR DAMAGE DUE TO UNUSUAL CONTAMINATION OR INFECTION, SPILLAGE OR STAINING, OR USE OF ABRASIVE, CORROSIVE OR ANY SUCH SIMILAR DAMAGING SUBSTANCE; DAMAGE DUE TO UNDERTAKING ANY ACTION OR PROCEDURE USING THE PRODUCT OUTSIDE ITS NORMAL AND INTENDED USE; DAMAGE RESULTING FROM FAILURE TO REPLACE DAMAGED PARTS PROMPTLY OR DAMAGE DUE TO INTERIOR PARTS BEING USED WITHOUT THE COVER, BEING USED WITH A DAMAGED COVER, OR WITH THE COVER BEING INCORRECTLY FITTED; DAMAGE WHEN ANY PARTS OF THE PRODUCT ARE USED AS PART OF, OR IN CONJUNCTION WITH, ANY OTHER PRODUCT OR PIECE OF EQUIPMENT EXCEPT AS SPECIFICALLY PROVIDED FOR BY ACCORA; DAMAGE NOT PROVEN TO THE SATISFACTION OF ACCORA TO BE DUE TO DEFECTIVE MATERIALS, WORKMANSHIP OR ASSEMBLY; OR PRODUCTS MODIFIED WITHOUT ACCORA EXPRESS WRITTEN CONSENT INCLUDING, BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS OR PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF ACCORA. IT IS A CONDITION OF THIS WARRANTY THAT THE FOLLOWING IS COMPLIED WITH:1) ALL INSTRUCTIONS FOR CLEANING AND MAINTENANCE OF THE PRODUCT ARE ADHERED TO. 2) THE INTERNAL AND EXTERNAL PARTS OF ANY PRODUCT ARE INSPECTED AT LEAST ONCE EVERY THREE (3) MONTHS FOR ANY DAMAGE AND WEAR. ALL DAMAGED PARTS ARE REPLACED IMMEDIATELY WITH THE APPROPRIATE REPLACEMENT PART, OR THE PRODUCT IS IMMEDIATELY TAKEN OUT OF SERVICE UNTIL THE REPLACEMENT PART HAS BEEN OBTAINED AND THE DAMAGED PART HAS BEEN REPLACED.THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER EXPRESS WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR, REPLACEMENT, OR REFUND OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. ACCORA SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER AND DISCLAIMS ANY LIABILITY BEYOND THE INITIAL PURCHASE PRICE OF THE PRODUCT. THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/ PROVINCIAL LAWS AND REQUIREMENTS.Technical DataMaterialsDimensionsIFU-FM1-001EN REV 03。

(整理)康姿百德磁性床垫结构及剖面示意图

(整理)康姿百德磁性床垫结构及剖面示意图
它在支持性、独立性、相互抗干扰性、透气性以及弹性、回弹性等方面都是无可比拟的,能自然顺应您的生理曲线,使身体各部位处于放松状态:腰部得到承托,臀部适度下陷,脊椎保持正常的生理弯曲。
● 强力高回弹聚氨基甲酸乙酯层
具有合适的柔软度、硬度和弹性与PS基础垫体层形成完美结合,承托人体后产生适度变形,与人体正常生理曲线完全吻合,符合人体工程学原理,使人感觉非常舒适。
折叠编辑本段分类构成
从现有的文案分类有很多种,按照4A标准,一般有四类:助理文案(ACW),文案(CW策划文案
策划文案
),高级文案(ACW),资深文案(SCW),其中稍微要区别的是高级文案与资深文案,前者要求的是文案的撰写能力,而后者不仅仅是文案的撰写能力还包括做文案的年资。有些4A公司设有文案主任(CE)一职,大体上与文案职责类似,有时候负责专项。另外有些个别公司还配有首席文案的职位(CCW),文案功力凤毛麟角,虽不具领导才能,但有的首席文案拿的工资却比创意总监还要高。大部分国内广告公司文案的种类繁杂,有房地产文案、创意文案、企划文案、品牌文案等。
基本信息
中文名称
文案
外文名称
Copy
1发展历程
2主要工作
3分类构成
4基本要求
5工作范围
6文案写法
7实际应用
折叠编辑本段发展历程
汉字"文案"(wénàn)是指古代官衙中掌管档案、负责起草文书的幕友,亦指官署中的公文、书信等;在现代,文案的称呼主要用在商业领域,其意义与中国古代所说的文案是有区别的。
在中国古代,文案亦作"文按"。公文案卷。《北堂书钞》卷六八引《汉杂事》:"先是公府掾多不视事,但以文案为务。"《晋书·桓温传》:"机务不可停废,常行文按宜为限日。"唐戴叔伦《答崔载华》诗:"文案日成堆,愁眉拽不开。"《资治通鉴·晋孝武帝太元十四年》:"诸曹皆得良吏以掌文按。"《花月痕》第五一回:"荷生觉得自己是替他掌文案。"

Protekt Aire Supreme Support 自调整空气 泡沫床垫说明书

Protekt Aire Supreme Support 自调整空气 泡沫床垫说明书

Operation ManualFORProtekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress with Optional Alternating Pressure PumpTable of ContentsIntroduction (4)Indications/Contraindications (4)Risks and Precautions (4)Preparation for Use (5)Mattress Installation (5)Patient Placement (5)To Use as a Static System (6)To Use as an Alternating Pressure System (6)Care and Cleaning (7)Preventative Maintenance Schedule (8)Troubleshooting (9)Specifications (10)Warranty (11)IntroductionThis manual is intended to be used for the initial set up and proper maintenance of the Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress with Optional Alternating Pressure Pump. It is important that you read and review these instructions in their entirety and consult with your healthcare professional if there are any questions. Carefully review the Indications and Risk and Precautions sections prior to placing a patient on any Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress.IndicationsThe Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress System (94001) provides non-powered zoned pressure redistribution, and the Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress with Optional Pump (94001-P) provides alternating pressure therapy. Both are indicated for the prevention and treatment of any and all stage pressure ulcers when used in conjunction with a comprehensive pressure ulcer management plan.The Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress support surface consists of 10 air cylinders that run laterally underneath the body and are contained in a foam cavity. On top of the air cells is a high-density foam coupled with a 1" thick gel infused memory foam layer zoned for pressure redistribution. The heel section is sloped to further redistribute pressure for the sensitive heel areas. Both the self-adjusting air cylinders and the foam top surface aid in pressure redistribution and in maintaining low interface pressures throughoutthe surface.Risk and PrecautionsTransfer: Standard precautions should be taken during patient transfer.Side Rails and Restraints:WARNING: Use or non-use of restraints, including side rails, can be critical to patient safety. Serious injury or death can result from the use (potential entrapment) or non-use (potential patient falls) of side rails or other restraints. Monitor patients frequently to guard against patient entrapment and/or falls.Patient Migration: Specialty surfaces have different shear and support characteristics than conventional surfaces and may increase risk of patient movement, sinking and/or migration into hazardous positions of entrapment and/or inadvertent bed exit. Monitor patients frequently to guard against patient entrapment and/or falls.Shock Hazard –DANGER!: When used as powered system, do not remove control unit case cover. Risk for electrical shock may occur if control unit is disassembled. Refer to qualified service personnel.Fluids: When used as a powered system, avoid spilling fluids on control unit. Fluids remaining on controls can cause corrosion, which may cause components to fail or operate erratically, possibly producing potential hazards for patient and staff. If spills do occur, unplug the unit immediately and clean fluid from control unit wearing rubber gloves while it is unplugged to avoid any possibility of shock. Once fluid is removed, check operation of components in area of spill.No Smoking in Bed: Smoking in bed can be dangerous. To avoid the risk of fire, smoking in bed should never be allowed.Disposal: At the end of useful life, dispose of waste according to local requirements.Preparation For Use1. Open shipping container and check for damages which may have occurred en route. DONOT USE SHARP INSTRUMENTS TO OPEN BOXES. DAMAGE TO MATTRESS COULD RESULT.2. Remove Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress from protectiveplastic cover.The mattress may appear wrinkled when unpacked. To remove wrinkles, allow mattress up to24 hours to accommodate; see Troubleshooting table for more information. Wrinkles will notaffect inflation or function. Mattress may be used immediately if needed3. Check mattresses surface for tears or cracking; do not use if tears or cracking are present. Ifany damages exist, please contact your local provider immediately.4. If re-installing the Protekt® Aire Supreme Support onto a new frame or for a new patient,check mattress surface for staining and soiling; clean and/or disinfect as required (see Care and Cleaning section).5. Level bed and lock brakes.6. Remove existing mattress from bed frame.Mattress Installation1. Position mattress on bed frame with logo facing up and heel slope section aligned at the footof the bed.2. Ensure mattress is properly positioned with no gaps between mattress and bed frame or siderails. Always use a standard healthcare bed frame with safeguards or protocols that may be appropriate. Frame and side rails must be properly sized relative to the mattress to help minimize any gaps that might entrap a patient’s head or body.Patient PlacementIt is recommended that all sections of this manual be read prior to patient placement. Carefully review the Contraindications, Risks and Precautions and Mattress Installation sections prior to placing a patient on any Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress. The Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress ships as an open system (the pump needs to be connected). The following are the instructions for using the system based on desired therapeutic function.To Use as a Non-Powered Self Adjusting Air System1. Transfer patient following all applicable safety rules and institution protocols.2. Center patient side-to-side and head-to-foot on Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress.3. Air in alternating cylinders will level out providing a static air surface adjusting to the patient.4. NOTE - If the tubes are left unattached to a pump, the Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress will operate as an open air system with air going in and out based on patient movement and will function as a Non-Powered Self Adjusting Air System To Use as an Alternating System – Protekt 3000 Pump Option1. At the foot end of the mattress, unzip the lower zipper and remove the tubing.2. Place pump on a horizontal surface or suspend on the end of bed frame with built-in hanger.3. Connect pump to hoses extending from the mattress. Ensure air hoses are not kinked andwill not be pinched by any articulated bed mechanisms.4. Ensure green Power switch is in the OFF position.5. Plug pump into a properly grounded wall outlet. (Verify power to this outlet is not controlled bya wall switch).6. Press green Power switch to the ON position. Air will begin to flow into mattress.7. Yellow LED indicates low air pressure; green LED indicates proper air pressure has beenreached and mattress is ready for patient placement.8. Rotate the comfort control knob on the control unit clockwise to increase the airflow forAlternating Therapy.9. Rotate the comfort control knob on the control unit counter-clockwise to reduce the airflow forAlternating Therapy.Ensure control unit hoses are properly connected to mattress for the desired function.To Use as an Alternating System - Protekt 4000 Pump Option1. At the foot end of the mattress, unzip the lower zipper and remove the tubing.2. Place pump on a horizontal surface or suspend on the end of bed frame with built-in hanger.3. Connect pump to hoses extending from the mattress. Ensure air hoses are not kinked andwill not be pinched by any articulated bed mechanisms.4. Ensure green Power switch is in the OFF position.5. Plug pump into a properly grounded wall outlet. (Verify power to this outlet is not controlled bya wall switch).6. Press Power switch button to the ON position. Air will begin to flow into mattress.7. Yellow LED indicates low air pressure; green LED indicates proper air pressure has beenreached and mattress is ready for patient placement.8. Adjust the digital weight setting on the pump to set the airflow for Alternating Therapy.Ensure control unit hoses are properly connected to mattress for the desired function.Washing and DisinfectionRoutine Care: Surface wipe with neutral detergent and lukewarm water. Rinse thoroughly with water and dry thoroughly.Disinfection: Surface wipe the cover with quaternary solution or 1:10 bleach/water mixture according to recommended protocols. Avoid over saturation and ensure the surface does not stay wet longer than the chemical manufacturer’s guidelines for proper disinfecting. Wipe up excess disinfectant after the recommended kill time has elapsed. Thoroughly rinse the surface of the mattress with clean water using a clean cloth. Allow the surface to completely air dry prior to use. Phenolics may be used for the vinyl bottom of the cover onlyStorageWhen not in use, mattress should be stored flat in a controlled climate room.Preventive Maintenance SchedulePreventive maintenance for the Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress consists of regular cleaning and an overall system evaluation to be performed at the intervals described below.All components must be cleaned, disinfected and inspected after each patient’s use and before use by a new patient. Always use standard precautions, treating all used equipment as contaminated. Institutions should follow local protocols for cleaning and disinfection. Inspection/System EvaluationCheck each of the following before placing the Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress with a new patient:1. Check mattress surface for tears or cracking; do not use if tears or cracks are present.2. Ensure mattress is free of stains and is not overly faded.3. Ensure air inlet hoses and connectors on mattress and control unit are clean andundamaged.4. Ensure control unit and power cord are clean and undamaged.5. Ensure control unit hanger brackets are secure and operate correctly.6. Ensure OFF/ON Power switch and comfort control knob both operate correctly.7. Attach control unit to the black Alternating Pressure hoses and power up to ensure there areno air leaks.It is recommended that all selections of this manual be reviewed before troubleshooting any Protekt® Aire Supreme Support Self-Adjusting Air/Foam MattressDo not to attempt troubleshooting beyond the scope of this manual or where the remedy recommends contacting a Proactive Medical service representative. Any unauthorized service, modification, alteration, or misuse may lead to serious injury and/or product damage and will void all applicable warranties.For questions regarding this product, a replacement User Manual, other replacement parts, maintenance or additional information about PROACTIVE MEDICAL products and services, contact your PROACTIVE MEDICAL representative.1011 Protekt® Aire Supreme Support Self-Adjusting Air/FoamMattress Five/Three Warranty:In connection with your purchase of a Protekt® Aire Supreme Support Self-Adjusting Air/Foam Mattress, PROACTIVE MEDICAL warrants , to the original purchaser, against manufacturer’s defects in material and/workmanship for a period of five (5) years from the date of purchase on the mattress and one (1) year from the date of purchase on the control unit under normal usage* and so long as all applicable procedures** are followed. Conditions and Limitations:Under this warranty, upon reasonable notice, PROACTIVE MEDICAL will replace or repair defective parts or whole units Covered under this warranty as its sole option. No returns or replacements will be allowed without authorization from PROACTIVE MEDICAL. This warranty applies to material/parts replacement costs and labor costs only and does not include shipping and handling costs or disposal fees.This warranty does not extend to, nor cover:• Patient wearables, such as, but not limited to, non-integrated Cover Sheet(s) and disposables used in conjunction with the mattress; or• Normal wear and tear; or• Damage, including rust, corrosion or product failure due to causes beyond PROACTIVE MEDICAL control, such as, but not limited to abuse, theft, fire, flood, wind, lightening, freezing, power failure, power reduction, clogging of mattress pores due to tobacco smoke, unusual atmospheric conditions, foam deterioration due to exposure to moisture or other acts of God; or• Damage to mattress or mattress handles through use of the mattress for patient transfer or transport.PROACTIVE MEDICAL reserves the right to make material changes to the product predicated upon availability of raw Materials of like quality.Service beyond that described in the User Manual must be carried out by PROACTIVE MEDICAL or such other entities as may be approved by PROACTIVE MEDICAL in writing.This warranty is VOID if:• Proof of purchase cannot be made by the original purchaser;• Adjustment, modification, maintenance, and/or repair beyond that described in the User Manual is carried out by entities not approved in writing by PROACTIVE MEDICAL• The electrical installation of the room does not comply with the appropriate national electrical wiring standards; • The equipment is not used in accordance with the instructions and warnings enumerated in the User Manual. This warranty is in no way to be construed as an extension of any periodic or preventive maintenance agreement, extended service agreement or in-service agreement entered into by the parties.THE FORGOING BASIC WARRANTY MADE BY PROACTIVE MEDICAL IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PROACTIVE MEDICAL IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND EXPENSES, INCLUDING DAMAGES TO PERSON OR PROPERTY, DUE IN WHOLE OR IN PART OF THE USE OF THIS PRODUCT EXCEPT AS OTHERWISE REQUIRED BY LAW.* Normal usage does not include misuse, abuse, alteration, modification, burns, punctures, improper handling, harsh cleaning solutions or drying procedures not recommended by the manufacturer, solutions no properly diluted as per product instructions or caustic staining agents.** Applicable procedures include, without limitation, those set out in the accompanying User Manual and other guidelines and Procedures provided by PROACTIVE MEDICAL .NOTE: To the extent any portion of this warranty is held invalid under federal law, such invalidity shall not affect the validity of the remaining portions of this warranty agreement, and the parties acknowledge that it is their intention that such provision (or portion thereof) shall be construed in a manner designed to effectuate the purpose of such provision to the maximum extent enforceable under applicable law. This warranty gives you specific legal rights and you may also have other rights which may vary from region to region.。

罗斯科医疗Aruba单层泡沫床垫-组I说明书

罗斯科医疗Aruba单层泡沫床垫-组I说明书

(800) 3-ROSCOEfax: (440) 572-4261T o Order:Roscoe Aruba Single Layer Contour Foam Mattress• Box Dimensions (L x W x H): 36” x 24” x 19.5”Product Features Product SpecificationsItem #Description UPC Size Shipping Weight Qty ARUBA-100Roscoe Aruba Single Layer Contour Foam Mattress ************76” x 35” x 6”25 lbs.each ARUBA-200Roscoe Aruba Single Layer Contour Foam Mattress ************80” x 35” x 6”26 lbs.each ARUBA-300Roscoe Aruba Single Layer Contour Foam Mattress ************84” x 35” x 6”27 lbs.each The Aruba Single Layer Contour Foam Mattress offers a therapeutically designed foam mattress core that was created with state-of-the-art technology to provide superior pressure relief and comfort in three distinct areas: head and shoulders, torso and lower extremities. Relief of pressure in these areas help to prevent capillary occlusion, shear, skin abrasion and moisture build up; all of which can cause skin breakdown. The computerized fabrication process offers a sculptured surface to maximize airflow for each section of the body for comfort, providing therapeutic support and pressure relief that is far superior to a conventional innerspring mattresses. The deluxe stretch nylon cover is durable, waterproof, anti-microbial and washable. It also features a waterfall zipper to prevent any fluids from reaching the foam mattress core. The bottom is constructed with a reinforced tri-laminate vinyl and non-slip protection for added safety.• Mattress–Foam mattress core– P ressure relief and comfort in three distinct areas: head andshoulders, torso and lower extremities.–Sculptured surface to maximize airflow– S upport and pressure relief that is far superior to conventionalinnerspring mattresses.• Deluxe Stretch Nylon Cover–Durable–Waterfall Zipper–Waterproof–Anti-microbial–Washable–Urethane laminate to reduce friction, shear & contamination–Bottom is reinforced tri-laminate vinyl with non-slip protection • Weight Capacity: 350 lbs.• M eets California Flame Retardancy Standards TB# 117, 129 and 603and Federal Standard 16 CFR 1633.• Warranty: T wo years on foam core/one year cover• HCPCS Code: E0184*Vinyl Base Reinforced tri-laminatevinyl and non-slip protectionand support * Providers are responsible for determining appropriate billing codes for Medicare Program claims. This information is included for your convenience and is not intended, nor should it be considered billing advice.Compare to:Drive Medical’s Part# 15019Roscoe Maui Dual Layer Foam Mattress • Box Dimensions (L x W x H): 36” x 24” x 19.5”Product Features Compare to:Drive Medical’s Multi-Ply Shearcare 700Product Specifications Item #Description UPC Size Shipping Weight Qty MAUI-100Roscoe Maui Dual Layer Foam Mattress ************76” x 35” x 6”24 lbs.each MAUI-200Roscoe Maui Dual Layer Foam Mattress ************80” x 35” x 6”25 lbs.each MAUI-300Roscoe Maui Dual Layer Foam Mattress ************84” x 35” x 6”26 lbs.each The Maui Dual Layer Foam Mattress offers a dual layer design utilizing a combination of materials to reduces pressure and increases airflow. The foundation is built from four inches of premium firm high density foam for maximum support. On the top sits 1½" of Ulti-Mat ®, a unique surface made of premium soft foam for enhanced comfort and pressure relief. With these two materials combined, you get a great surface to help reduce skin temperature and enhance comfort. The deluxe stretch nylon cover is durable, waterproof, anti-microbial and washable. It also features a waterfall zipper to prevent any fluids from reaching the foam mattress core. The bottom is constructed with a reinforced tri-laminate vinyl and non-slip protection for added safety. • Mattress –T wo-layer design for support, comfort and pressure redistribution –Base : 4" premium firm high density foam –T op : 1½" of premium soft foam with Ulti-Mat ® surface • Deluxe Stretch Nylon Cover –Durable –Waterfall Zipper –Waterproof –Anti-microbial –Washable –Urethane laminate to reduce friction, shear & contamination –Bottom is reinforced tri-laminate vinyl with non-slip protection • Weight Capacity: 350 lbs.• M eets California Flame Retardancy Standards TB# 117, 129 and 603 and Federal Standard 16 CFR 1633.• Warranty: Five years on foam core/one year cover • HCPCS Code:E0184*vinyl and non-slip protection density foam * Providers are responsible for determining appropriate billing codes for Medicare Program claims. This information is included for your convenience and is not intended, nor should it be considered billing advice. (800) 3-ROSCOE T o Order:Roscoe T ahiti Dual Layer Pressure Relieving Foam Mattress • Box Dimensions (L x W x H): 36" x 24" x 19.5"Product Features Compare to:Drive Medical’s Gravity 7Product SpecificationsItem #Description UPC Size Shipping Weight Qty TAHITI-100Roscoe Tahiti Dual Layer Pressure Relieving Foam Mattress ************76” x 35” x 6”24 lbs.each TAHITI-200Roscoe Tahiti Dual Layer Pressure Relieving Foam Mattress ************80” x 35” x 6”25 lbs.each TAHITI-300Roscoe Tahiti Dual Layer Pressure Relieving Foam Mattress ************84” x 35” x 6”26 lbs.each The T ahiti Dual Layer Foam Mattress offers a multi-sectional design incorporates four different types of foam to reduces pressure and increases airflow. The foundation is built from four inches of premium firm high density foam for maximum support. On the top sits 1½" of Ulti-Mat ®, a unique surface made of premium soft foam for enhanced comfort and pressure relief, as well as a pillow top foam for the heel section to assist in added pressure relief of the lower extremities. With these materials combined, you get a great surface to help reduce skin temperature and enhance comfort.The deluxe stretch nylon cover is durable, waterproof, anti-microbial and washable. It also features a waterfall zipper to prevent any fluids from reaching the foam mattress core. The bottom is constructed with a reinforced tri-laminate vinyl and non-slip protection for added safety.• Mattress– M ulti-sectional design for support, comfort and pressureredistribution–Base : 4" premium firm high density foam–T op, T orso : 1½" of premium soft foam with Ulti-Mat ® surface–T op, Heel : 1½" of pillow top foam• Deluxe Stretch Nylon Cover–Durable–Waterfall Zipper–Waterproof–Anti-microbial–Washable–Urethane laminate to reduce friction, shear & contamination –Bottom is reinforced tri-laminate vinyl with non-slip protection• Weight Capacity: 350 lbs.• M eets California Flame Retardancy Standards TB# 117, 129 and 603and Federal Standard 16 CFR 1633.• Warranty: Five years on foam core/one year cover• HCPCS Code: E0184*vinyl and non-slip protectiondensity foam * Providers are responsible for determining appropriate billing codes for Medicare Program claims. This information is included for your convenience and is not intended, nor should it be considered billing advice.(800) 3-ROSCOEfax: (440) 572-4261T o Order:Roscoe Rio T ri-Layer Pressure Relieving Foam Mattress • Box Dimensions (L x W x H): 36” x 24” x 19.5”Product Features Compare to:Drive Medical’s Gravity 8/9Product Specifications Item #Description UPC Size Shipping Weight Qty RIO-100Roscoe Rio Tri-Layer Pressure Relieving Foam Mattress ************76” x 35” x 6”25 lbs.each RIO-200Roscoe Rio Tri-Layer Pressure Relieving Foam Mattress ************80” x 35” x 6”26 lbs.each RIO-300Roscoe Rio Tri-Layer Pressure Relieving Foam Mattress ************84” x 35” x 6”27 lbs.each The Rio Tri-Layer Pressure Relieiving Foam Mattress offers our most advanced therapeutic design for patients that require the highest degree of pressure relief. This multi-sectional design incorporates four different types of foam to provide a therapeutic pressure relieving surface that enhances patient comfort and support. The top layer’s Ulti-Mat ® surface reduces pressure and increases airflow thereby reducing skin temperature and enhancing comfort. The heel section uses pressure relieving Visco-Elastic foam to cradle the sensitive heel area. The center layer of medium firm foam provides added support and comfort in the head and torso along with integrated pillow-soft foam at the foot end. The mattress contains a Premium firm base layer for maximum support with Integrated side rails to ensure patient safety during ingress and egress.The premium Soflux LVT ™ nylon cover offers the greatest protection against friction and shearing. It is extremely durable, waterproof, anti-microbial and washable. It also features a waterfall zipper to prevent any fluids from reaching the foam mattress core. The bottom is constructed with a reinforced tri-laminate vinyl and non-slip protection for added safety. • Mattress – M ulti-sectional design for support, comfort and pressure redistribution – B ase: Premium base layer w/ Integrated side rails –Middle: Medium firm foam –T op, T orso: Premium soft foam with Ulti-Mat ® surface –T op, Heel: Visco-Elastic foam • Premium Nylon Cover –Durable –Waterfall Zipper –Waterproof –Anti-microbial –Washable –Soflux LVT ™ nylon to reduce friction, shear & contamination –Bottom is reinforced tri-laminate vinyl with non-slip protection • Weight Capacity: 400 lbs.• M eets California Flame Retardancy Standards TB# 117, 129 and 603 and Federal Standard 16 CFR 1633.• Warranty: Five years on foam core/one year cover •HCPCS Code: E0184*™w/ integrated pillow-soft foam at the foot end * Providers are responsible for determining appropriate billing codes for Medicare Program claims. This information is included for your convenience and is not intended, nor should it be considered billing advice. (800) 3-ROSCOE fax: (440) 572-4261T o Order:Roscoe Milan Bariatric Pressure Relieving Foam Mattress • Box Dimensions (L x W x H):MILAN-100 — 36" x 24" x 19.5"MILAN-200 — 42" x 24" x 19.5"MILAN-300 — 48" x 24" x 19.5"Product Features Product SpecificationsItem #Description UPC Size Shipping Weight Qty MILAN-100Roscoe Milan Bariatric Pressure Relieving Foam Mattress ************76" x 35" x 6"34 lbs.each MILAN-200Roscoe Milan Bariatric Pressure Relieving Foam Mattress ************80" x 40" x 6"40 lbs.each MILAN-300Roscoe Milan Bariatric Pressure Relieving Foam Mattress ************84" x 48" x 6"45 lbs.each The Roscoe Milan Bariatric Pressure Relieving Foam Mattress is the most unique bariatric mattress on the market for all patients types. This mattress offers two sides of comfort for patient use. The multi-layer design incorporates three different types of foam to provide a therapeutic pressure relieving surface that enhances patient comfort and support on both sides. The top and bottom layer’s Ulti-Mat surface reduces pressure and increases airflow thereby reducing skin temperature and enhancing comfort. Full height integrated side rails to ensure patient safety during ingress and egress.The outer cover is nylon on one side and a soft urethane stretch fabric on the other to offer the patient a choice of enhanced comfort. It also features a waterfall zipper to prevent any fluids from reaching the foam mattress core.• Mattress– M ulti-sectional design for support, comfort and pressure redistribution–T op & Bottom: Premium soft foam with Ulti-Mat ® surface–Height Support: Integrated side rails–Middle: Medium firm foam• Reversable Cover–Deluxe Stretch nylon/Soft urethane stretch fabric–Durable–Waterfall Zipper–Waterproof–Anti-microbial–Washable• Weight Capacity: 550 lbs.• M eets California Flame Retardancy Standards TB# 117, 129 and 603 and Federal Standard 16 CFR 1633.• Warranty: Five years on foam core/one year cover• HCPCS Code: E0184*w/ integrated pillow-soft foam at the foot end * Providers are responsible for determining appropriate billing codes for Medicare Program claims. This information is included for your convenience and is not intended, nor should it be considered billing advice.(800) 3-ROSCOET o Order:____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________A Division of Compass Health Brands。

Rexx Advantage床垫扩展器系列说明书

Rexx Advantage床垫扩展器系列说明书

The expanders are fully compatible with Span MC half head assist rails. The rails should be fitted to the head deck expander units prior toinstallation. See p. 2 for instructions.Q-Series 42” Expander Kit (Kit# Q6709 for Rexx and Advantage beds)The Span MC Expanders Kit part no Q6709 is supplied with form-fitted packaging for protective storage and reuse. The kit contains 6 expander units and two mattress retainers, one each for the center of the head and foot decks for additional stability with wider mattresses in some applications.If the bed is fitted with half head assist rails it is necessary to remove them and the four corner mattress retainers prior to installation of the expanders. The six expander units will then install toollessly, converting the sleep surface to a 42" width. We recommend storing the original corner mattress retainers in the kit for reuse.Note the placement decals on each of the six unique expander units and prepare to install them on either side of the head, seat and foot decks.Using the figure (upper left) as a guide, connect each expander unit to the upper surface of the grid deck and then lower the expander until the spring loaded retaininglatch attaches securely to the lower portion of the deck.BEDS AND FURNITURE MC STEP 1STEP 3STEP 2Bed frame, overhead view.To remove and install half headassist rails, follow theseinstructions which apply tomolded plastic or steel rails:Removal: Using the 5/32” hex(Allen) wrench, remove the1/4-20 X 5/8 flat head screwsfrom the 1/2 rail assemblies, thenremove the equalizer bar assem-bly, wave washers, and themounting channel. The mountingchannels are not used with thiskit.Installation: Install the righthand 1/2 rail into the mountingtubes on the underside of theright hand head deck expander,then re-install the wave washers,right hand equalizer bar assem-bly (each casting is marked “R”)and 1/4-20 X 5/8 flat headscrews. The equalizer barassembly must be oriented to theraising arms. Verify that the railswings through its full range ofmotion and that it will latch inthe upright position. Repeat forthe left hand side 1/2 rail.42” Expander for Rexx/Advantage Grid Deck - Kit Q6709。

床垫材质说明

床垫材质说明

床垫材质要点1、大芯拉网式弹簧:弹簧采用70号优质碳素钢制成,弹力具整体性,弹簧芯子大,弹性好,经热处理后,持久耐用,不易变型,床网更坚固,床垫的回弹力更强,起到均衡承托人体的作用。

2、独立筒弹簧:最高档的床垫承托弹簧,每个弹簧之间互相独立,互不干扰,分别承托身体各个部位的重量,保持身体自然曲线,在翻身时不会影响到睡伴。

经8000磅压路车当众碾压实验,迅速回弹丝毫无损。

3、7区橄榄型独立筒弹簧:弹簧形状和橄榄一样,中间大两头小,弹性特别好,非常柔软,按人体工程学,分五个区位软硬不同,分别承托身体各个部位的重量,保持身体自然曲线,在翻身时不会影响到睡伴。

经20吨压路车当众碾压实验,迅速回弹丝毫无损。

5、环保热熔棉:采用棉纤维高温消毒压制而成,确保床垫的卫生,吸热收汗,防潮防霉,更保健康。

6、天然椰棕:采用泰国进口椰壳纤维,经过脱脂、防蛀、防菌处理,不会太硬,也不会太软,保持卓越透气透水性能,冬暖夏凉,是喜欢睡硬床垫人的首选。

7、天然山棕:采用云贵高原的优质山棕和天然乳胶为原料,将山棕经过蒸煮、碾压、分解、喷胶、垫压定型等工序精制而成,不易变型。

因山棕树生长在高寒山区,具有强度高、弹性好、抗腐蚀、防蛀虫、气味清香、透气性强、不吸水、防潮性好,从古至今被用于日常生活中。

经人体工程学研究证明为最佳的床垫软硬使用指数,冬暖夏凉,四季皆宜。

8、竹炭:竹通过最新工艺烧制成竹炭,具有七大特殊神效。

(1)调节环境——其表面细蜜的小孔能大量地释放负离子,这种负离子对保鲜和改善空气环境起着重要作用。

(2)远红外线——研究发现竹炭能发出神奇的远红外线,这种远红外线对消除人体疲劳、肩膀酸痛、腰、颈椎、关节痛、失眠、气喘等症有明显的辅疗作用。

(3)抗毒素——竹炭可以及时对人体睡觉所排出汗液内的毒素进行抑杀和清理,防止汗液渗透到床上,保护床的清洁。

(4)防螨虫——竹炭是很好的吸附材料,保证了床垫相对的湿度和温度,使螨虫失去生存的环境。

宜家床垫质量手册 中文版

宜家床垫质量手册 中文版

床垫质量手册 — 版本 2.02013年4月版本 2.0床垫质量手册- 舒适睡眠指南波兰 华沙 TACE 2013年4月编制: Bartosz Staniaszek TACE 床垫工程师更新: Anna Rynska Cieszkowska 审核:床垫组质量主管TACE 产品质量副经理1. 背景......................................................................................................... - 3 -2. 质量等级................................................................................................... - 3 -3. 验收标准................................................................................................... - 3 -3.1. 包装和标签........................................................................................ - 3 -3.1.1. 整托包装................................................................................... - 3 -3.1.2. 销售包装................................................................................... - 4 -3.2. 成品................................................................................................ - 7 -3.2.1. 产品标识................................................................................... - 7 -3.2.2. 纺织品......................................................................................... - 8 -3.2.3. 拉链....................................................................................... - 10 -3.2.4. 工艺 ...................................................................................... - 10 -3.2.5. 气味....................................................................................... - 13 -3.3. 成分 ............................................................................................. - 14 -3.3.1. 海绵&乳胶 .............................................................................. - 14 -3.3.2. 木材...................................................................................... - 15 -4. 测量方法................................................................................................. - 17 -5. 专业修补................................................................................................. - 19 -6. 检验流程和抽样计划................................................................................... - 20 -7. 测试....................................................................................................... - 21 -8. 质量指南矩阵/检查表.................................................................................. - 22 -9. 附录—参考文件...................................................................................... - 23 -宜家床垫产品在全球范围内的扩大使其需要统一质量要求及验收标准,以防止出现因观点不同而导致的质量差异。

蓝芝医疗产品-POWER-PRO Elite 低气压床垫系统说明书

蓝芝医疗产品-POWER-PRO Elite 低气压床垫系统说明书

The blower pump is controlled by a micro-processor which allows the •Hose connections feature a transport locking device that ensures themattress remains inflated for patient transport.Model 9500Mattress & Pump System polyurethane material. Dual bladder design prevents patients from bottoming out, while sitting up and will maintain air during power outages. CPR Valve quickly deflates mattress system for medical emergencies. A simple twist releases air immediately. P ower-Pro ®-EXP Expandable Mattress SystemSpecifications "Setting the Standard"Medical Products, Inc.SPECIFICATIONS ®POWER-PRO ®MODEL 9511 - POWER-PRO ®ELITE PUMP ONL YDimensions:17L" x 7W" x 10.5H"Weight:12 lbs.Electrical:120V 60 hzListings:Cycle Time: 5 - 95 MinutesAir Flow:1800 Liters per minuteCurrent:5AGround Resistance:0.1 ohms maximumP ower Cord:12 ft. cord with hospital grade plug Model 9511 Pump only ORDERING INFORMATIONModel 9500 P ower-Pro ®Elite 650 lbs. Capacity 36” x 80” x 9”Model 9542BAR P ower-Pro ®Elite 800 lbs. Capacity 42” x 80” x 9”Model 9548BAR P ower-Pro ®Elite 1000 lbs. Capacity 48” x 80” x 9”Model 9511 P ower-Pro ®Elite pump onlyModel 9511-PS P ower-Pro ®Elite pump with pulsating low air loss Model 9502 P ower-Pro ®Mattress only with Zippered Quilted Cover 36”Model 9502-42 P ower-Pro ®Mattress only with Zippered Quilted Cover 42”Model 9502-48 P ower-Pro ®Mattress only with Zippered Quilted Cover 48”Model 9526-SRS P ower-Pro ®Replacement SRS side rail safety system cover Model 9500-EXP-2P ower-Pro ®Expandable Width Sizes: 35"-42"-48”, 1000 lbs.Additional Expandable Width Sizes Available. (special order)MODEL 9500 - POWER-PRO ®ELITE MATTRESS & PUMPDimensions:36" x 80" x 9"Weight:23 lbs.Air Cells:18 - 9" Air cells Ventilated bladders with air holes throughout the mattress.Mattress Cover:Vyvex-III ® - Urethane coated, multi-stretch, low shear, moisture resistant / vapor permeable quilted cover. Removable, zippered cover, is anti-microbial and meets California Technical Bulletin #117 for fire-retardancy.P ower-Pro ®Elite meets Group 2 Support Surface requirements for Medicare EO277. P atient must meet all medical criteria to qualify for reimbursement.PDAC Approved Medicare E0277B lue C hip ©Blue Chip Medical Products, Inc. 2015。

SMD 57床垫使用说明书

SMD 57床垫使用说明书

Kulllanma TalimatıORIGINAL OPERATING INSTRUCTIONSSMD 57magazineIt is essential that the operating instructions are read before the tool is operated for the first time.Always keep these operating instructions to-gether with the tool.Ensure that the operating instructions arewith the tool when it is given to other persons.1These numbers refer to the corresponding illustra-tions.The illustrations can be found on the fold-out cover pages.Keep these pages open while studying the oper-ating instructions.Operating controls and parts of the magazine 1@Depth gauge;Screw length adjustment button =Screw length marks%Screwdriving depth adjustment thumbwheel &Release buttons (Strip guide )Transport latch+Lockbutton for sustained operation §Strip releaseDraws attention to imminent danger that will lead to serious bodily injury or fatality.WARNINGDraws attention to a potentially dangerous situation that could lead to serious personal injury or fatality.CAUTIONDraws attention to a potentially dangerous situation that could lead to slight personal injury or damage to the equipment or other property.NOTEDraws attention to an instruction or other useful informa-tion.General warning Warning:electricityObligation signsWear eye protection Wear a hardhat Wear ear protectionWear protective glovesSymbolsReturn wastematerial forrecycling.Read theoperatinginstructionsbefore use.Location of identification data on the toolThe type designation and the serial number are stampedon the rear of the magazine.Make a note of this data inyour operating instructions and always refer to it whenmaking an enquiry to your Hilti representative or servicedepartment.Type:Serial no.:collated screws.The magazine is suitable for use withthe Hilti SF4000/SF4000‑A/SD2500/SD4500/SD5000/SD5000‑A22/SD4500‑A18and SD45screwdrivers.The magazine and Hilti screwdrivers areoptimally matched to each other.In the safety rules in these operating instructions,thedesignation“power tool”refers to the magazine.Modification of the power tool is not permissible.Observe the information printed in the operating instruc-tions concerning operation,care and maintenance.To avoid the risk of injury,use only genuine Hilti ac-cessories and insert tools.The power tool and its ancillary equipment may presenthazards when used incorrectly by untrained personnel orwhen used not as directed.The power tool is designed for professional use and maybe operated,serviced and maintained only by trained,authorized personnel.This personnel must be informed ofany special hazards that may be encountered.The powertool and its ancillary equipment may present hazardswhen used incorrectly by untrained personnel or whenused not as directed.The working environment may be as follows:constructionsite,workshop,renovation,conversion or new construc-tion.Working on materials hazardous to the health(e.g.as-bestos)is not permissible.1Magazine1S‑MBL116PH2bit1Operating instructions1Cardboard boxDesignationS‑MBL116PH2bitSME extensionSMD57magazine2;Magazine unit,complete382905=Depth gauge383002Right of technical changes reserved.Magazine SMD 57WeightWithout screwdriver,Without screw strip:0.35kg Length186mm Contact pressureto 40N (4.0kp)Screw capacity (screws per strip)50Suitable drywall screw types SMD 57Length9…57mm Thread inside diameter 3…4.5mm Head diameter 7.5…8.6mmDrive typePhilips no.2(S‑MBL 116PH2)Philips no.2can be driven with the following Hilti screwdriversSF 4000/SF 4000‑A /SD 5000/SD 2500/SD 4500/SD 5000‑A22/SD 4500‑A18/SD 45common sense when operating a power tool.Do not use a power tool while you are tired or under the influence of drugs,alcohol or medication.A moment of inattention while operating power tools may result in serious personal injury.b)Use the power tool,accessories and tool bits etc.in accordance with these instructions,taking into account the working conditions and the work to be e of the power tool for opera-tions different from those intended could result in a hazardous situation.c)Maintain power tools.Check for misalignment orbinding of moving parts,breakage of parts and any other condition that may affect the power tool’s operation.If damaged,have the power tool repaired before use.Many accidents are caused by poorly maintained power tools.d)Store idle power tools out of the reach of chil-dren and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool.Power tools are dangerous in the hands of untrained users.e)Dress properly.Do not wear loose clothing orjewellery.Keep your hair,clothing and gloves away from moving parts.Loose clothes,jewellery or long hair can be caught in moving parts.f)Use personal protective equipment.Always weareye protection.Protective equipment such as dust mask,non-skid safety shoes,hard hat,or hearing protection used for appropriate conditions will reduce personal injuries.a)Observe the operating instructions and the safety rules contained for the magazine and the screw-driver used.b)Always work with the screwdriver running at max-imum speed.Accordingly,use the switch lockbut-ton on the screwdriver.c)Do not hold the SMD 57magazine in the area ofthe depth gauge.d)Each screwdriving stroke must be completed infull.Interruption of the magazine stroke or release of pressure half way through the screwdriving operation may lead to malfunctions.e)Change the screw strip only when the screwdriveris switched off.f)Wear eye protection,especially when workingoverhead.g)Use only genuine Hilti S‑MBL 116PH2bits.Checkthat the bits are in good condition.h)Use only genuine Hilti screw strips and screws.i)Always work at right angles to the surface of theworkpiece to be fastened.j)Store the screw strips in a straight position,asthey are in the original package.Disconnect the screwdriver’s supply cord from the elec-tric supply before fitting the magazine.1.Remove the depth gauge and bit holder from thescrewdriver.2.Fit the bit into the screwdriver.NOTE The bit clicks into position.3.Push the magazine onto the screwdriver in the de-sired working position until it is heard to engage.NOTE The magazine can be engaged on the tool invarious positions(every15°).NOTE Check to ensure that the screwdriver is setto“forward”rotation.screws to be driven.2.Press the button and slide the depth gauge back orforward.3.Set the depth gauge to one of the5length markscorresponding to the length of the screws.NOTE The correct screw length setting is very im-portant for trouble-free magazine operation.channel until the first screw is in position at the markor until the end of the strip is flush with the uppersurface of the magazine at the exit opening.2.Check that the screw strip has engaged by trying topull it back gently.thumbwheel.2.Turning the thumbwheel counterclockwise causesthe screw to be driven deeper.3.Drive a screw to test the screwdriving depth setting.Readjust the setting if necessary.NOTE Each audible click of the thumbwheel corres-ponds to an adjustment of0.2mm(0.008inch).Turning the thumbwheel clockwise causes the screwto be driven less deeply.Disconnect the screwdriver’s supply cord from the elec-tric supply.1.Release the strip retainer by pressing the transportlatch.2.Pull the screw strip back.NOTE Alternatively,the screw strip can be pulledupwards,out of the magazine,without pressing thetransport latch.Disconnect the screwdriver’s supply cord from the elec-tric supply before removing the magazine.The magazine can be removed by pressing the releasebuttons and,at the same time,pulling it away from thescrewdriver.Dirt and dust(especially from plaster)may have an ad-verse effect on operation of the magazine.CAUTIONDo not,under any circumstances,lubricate themagazine with mineral oil/grease or graphitesprays.This would increase the risk of malfunctions.Clean the magazine simply by blowing out the dirt anddust with compressed air.It is recommended that the magazine is cleaned by wash-ing it out with warm water after a long period of heavyuse.1.Remove the screw strip as described in the section“Moving the screw strip back”.2.Remove the magazine as described in the section“Removing the magazine from the screwdriver”.3.Press the release spring together with the aid ofpliers or a similar tool.The transport mechanism,including the depth gauge,can then be removedfrom the casing.You now have three assemblies inyour hand:the transport mechanism,the pressurespring and the casing.4.If necessary,the depth gauge can also be separatedfrom the other parts by pulling it out while pressingthe screw length adjustment button.NOTE Take care to avoid pinching your fingers.5.The parts can then be cleaned thoroughly with warmwater.NOTE We recommend use of a nylon brush(an oldtoothbrush)to remove stubborn deposits.Operate the transport movement once or twice to checkthat the magazine is functioning correctly after cleaningand reassembly.Most of the materials from which Hilti tools or appliances are manufactured can be recycled.The materials must be correctly separated before they can be recycled.In many countries,Hilti has already made arrangements for taking back old tools and appliances for recycling.Ask Hilti customer service or your Hilti representative for further information.Hilti warrants that the tool supplied is free of defects inmaterial and workmanship.This warranty is valid so longas the tool is operated and handled correctly,cleanedand serviced properly and in accordance with the HiltiOperating Instructions,and the technical system is main-tained.This means that only original Hilti consumables,components and spare parts may be used in the tool.This warranty provides the free-of-charge repair or re-placement of defective parts only over the entire lifespanof the tool.Parts requiring repair or replacement as aresult of normal wear and tear are not covered by thiswarranty.Additional claims are excluded,unless stringent na-tional rules prohibit such exclusion.In particular,Hiltiis not obligated for direct,indirect,incidental or con-sequential damages,losses or expenses in connec-tion with,or by reason of,the use of,or inability touse the tool for any purpose.Implied warranties ofmerchantability or fitness for a particular purpose arespecifically excluded.For repair or replacement,send the tool or related partsimmediately upon discovery of the defect to the addressof the local Hilti marketing organization provided.This constitutes Hilti’s entire obligation with regard towarranty and supersedes all prior or contemporaneouscomments and oral or written agreements concerningwarranties.73157*57Hilti CorporationLI-9494Schaan Tel.:+423/2342111Fax:+423/Hilti =registered trademark of Hilti Corp.,Schaan W 3197|1212|00-Pos.1|1。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

睡眠类知识睡眠的重要性:✓按照平均一天八小时睡眠来计算,人的一生中,有三分之一的时间与床共眠✓充足的睡眠,可以带来精神和活力,恢复身体机能运作和朝气,令身心舒泰床垫与睡眠的关系:✓床垫质量的好坏直接影响到人的睡眠与健康✓床垫在健康睡眠中充当了重要的角色,床垫具有整体、充分、均匀、贴身的承托力,能保持脊柱天然弯曲✓好的床垫弹簧性能佳,结构好,垫层厚且用料讲究,整个床垫软硬适中,整体承托力佳,能适合人体体形和重力分布,使身体各部分都得到均匀而贴身的承托和支持,保护脊柱整体正位和颈、胸、腰段的天然弧度(也即正常曲线),同时也可使身体各部分的肌肉(尤其是腰背的肌肉)得到松弛和休息,有助于身心放松和安睡。

✓要保证睡眠健康、舒适,就应该选购“卫生、舒适、美观、耐用”的床垫。

选购床垫的方法几个步骤帮您最快找到您要的床垫●您需要什么尺寸规格的床垫?●您喜欢什么软硬度的床垫?●您喜欢什么材质的床垫?●您打算购买什么价位的床垫?●其他的一些需要考虑的问题:✓性价比✓产品标识完整清晰✓外观:床垫表面平整,缝制严密工整✓味道:没有奇怪或难闻的味道✓品牌:品牌是质量和信誉的保障✓外观面料款式●床垫的身体贴合度测试身体平躺:手掌摊平,可以自如地插入颈部、腰部等曲线部位与床垫的接触面身体侧躺:手掌摊平,可以自如地插入颈部、腰部等曲线部位与床垫的接触面床垫的保养保养知识✓每三个月,将床垫翻转一次,例如首先头尾对调,之后正反对调,之后再头尾对调✓避免在床上任意过度跳跃✓避免折曲✓避免长期坐在边缘的固定位置✓避免阳光长期直射✓床面污染时,用去污清刷,並用电风扇吹干或阴干✓定期用吸尘器清理床墊、阴湿天气,使用除湿机,保持床面干燥✓使用床单或床罩,保持床面干净整洁床垫的使用寿命山棕床垫:20年以上弹簧床垫:10-15年椰棕床垫:10-15年乳胶床垫:10-15年泡绵床垫:5-10年小花费,换来完美的睡眠以价格为1500元的床垫为例,使用寿命按照10年测算,平均每天不到5角钱即可以享受每日8小时的睡眠各种材质床垫的特点介绍山棕(重点介绍)山棕图片●外观(详见小样):呈深褐色,●材质:山棕是用生长在我国西南海拔2000米左右山地上棕榈树的叶鞘制作而成,山棕的纤维比较粗、长、韧性要好一些、强度要大一些,还有就是山棕的软硬度是比较适中的,它介于硬板床和弹簧垫之间、柔韧性特别好,中国的山棕原料主要来自于海南和云南●山棕和椰棕的对比价格:山棕因其良好的性能和稀缺的材料来源,价格要高于椰棕床垫弹性:山棕远优于椰棕透气性:山棕优于椰棕使用寿命:山棕优于椰棕●山棕床垫品牌:市场上纯山棕床垫品牌屈指可数,大自然是最有代表性的山棕床垫品牌,欢颜是国内最专业的产量最大的山棕材料供应商,为诸多品牌床垫提供山棕原材料,包括大自然,此外,以欢颜自有品牌命名的山棕床垫是市场上最专业最环保的天然山棕床垫。

●山棕的特点:✓透水透气:它吸到人体的汗水会从底部散发掉,不象有海绵或棉花的床垫一有热量水气就会往上蒸发,使人体毛孔重复吸收有细菌及污染的汗水,进入皮层及关节处,造成风湿及关节疼痛,特别是人到中年开始的感受最深。

✓环保、防潮、防菌、寿命长:可以垫45-50年不会变质;不用时可卷起,储存简单方便。

棕丝的诸多优点从古至今被用于日常生活中:如蓑衣(抗腐蚀、防虫蛀)、井绳绳索(抗腐蚀、防虫蛀、强度高)✓软硬适中:棕藤坐垫/床垫软硬适中,柔韧性好,适合中式家具,符合人体的最佳床垫软硬指数✓绿色产品:全天然棕藤,纯植物弹簧,冬暖夏凉,无化学污染,符合目前的绿色消费趋势✓弹性适中:受力均衡,能使睡眠中受力最大的头部、肩部、臀部三点受到均衡的承托力,不论侧睡、俯睡、仰睡,每一接触面都均匀受力。

它不象海绵床垫,会变形,造成人体骨质不平衡而产生骨质疏松,或影响孩子的骨骼正常发育。

特别适用于中老年人和处于生长发育期的青少年✓无噪音:采用优质的棕丝制作,即使在床面跳跃翻滚,依然悄无声息,不会产生机械噪音,保证睡眠质量。

椰棕椰棕图片●外观:呈浅黄色●材质:椰棕床垫是用我国南方热带地区海岸或河岸生长的椰树的椰子果皮纤维制作而成的,椰丝的纤维比较短、比较脆、强度要差一些、弹性也比较小弹簧(重点介绍)1.弹簧床垫的材料构成一张弹簧床垫一般都由弹簧床芯,填充物,复合面料三部分构成,这三部分各司其职,综合构成适合人体躺卧睡眠的环境平台。

✓弹簧床芯是弹簧床垫的核心部件,是由众多钢丝弹簧组成的弹性综合体,它担负着一张床垫最重要的功能,即合理支撑人体各个部分,始终保持人体骨骼的正确躺卧姿势。

由于人体体重的颁布不均和脊椎骨骼的曲线构成,能否人体曲线进行合理支撑,尤其是对腰部的支撑,是对弹簧床芯进行评价的重要指标。

✓填充物:填充物采用透气、贴身、舒适的物质,如天然乳胶,马毛,羊毛,棉等。

✓复合面料:面料采用亲肤性佳,有良好透气性,并经过防尘,防菌,防霉和防螨处理,经过防静电和耐磨处理。

2.弹簧床垫分类:✓连锁式弹簧床垫:用螺旋状铁线将所有个体弹簧串连在一起,成为“受力共同体”,虽稍具弹力,但因弹簧系统不完全符合人体工学设计,牵一发而动全身,一处受压,附近的弹簧都会相互牵扯。

✓袋装独立筒弹簧床垫:将每一个独立体弹簧施压之后装填入袋,再加以连结排列而成。

其特色是每个弹簧体皆个别运作,独立支撑,能单独伸缩,各个弹簧再以纤维袋或棉袋装起来,而不同列间的弹簧袋再以粘胶互相粘合,因此当两个物体同置于床面时,一方转动,另一方不会受到干扰。

✓线装直立式弹簧床垫:由一股连绵不断的精钢线,从头到尾一体成型排列而成。

其特点是采取整体无断层式架构弹簧,顺着人体脊骨自然曲线,适当而均匀地承托。

贴士:在弹簧床垫上试跳不失为检测弹簧床质量的好方法。

如果床垫一跳就凹陷变形,则不必考虑。

如果选择连锁弹簧排列的弹簧床,建议选择中度偏硬的床垫。

如果选择独立弹簧的床垫,则不能用排骨架的床板,需要一张整板,或者在排骨架上再垫一层木板。

目前,市场上流行独立弹簧排列的双床垫,也有两面可以翻转睡的弹簧床,都是不错的选择。

乳胶1.材质:天然乳胶,胶由橡树乳汁提炼而成,初取粹炼精华为白绸胶绸,乳胶本身不具任何感染性之物质,胶性温和亲肤,其淡淡清香更能摧化人体睡眠因子,是目前最为天然的睡眠素材。

自然透气、不吸灰尘、散热、抗霉、柔软舒适的十足弹性,促使人体各部位完全贴合床面使身体的每一吋肌肤完全感受乳胶的特殊弹力,使身体的骨骼得以完全舒展,不论各种动作,天然乳胶均匀的给身体各部位最贴切的支持,让您充分的享受休息。

一般乳胶棉襑垫扎实柔软、弹性均匀、不易变型,可以给你舒适的支撑喔!而且乳胶棉的透气性佳,不易发霉,其材质具有防尘满的效果。

2.乳胶床垫具有七大优点:✓超高弹性:天然乳胶的超高弹性与服贴性让乳胶床垫可承载不同体重之人体,以最佳的支撑力去自然适应睡眠者的任何姿势,解除因睡眠所造成的腰酸与不易入睡。

✓矫形功能:乳胶床垫接触人体面积比普通床垫接触人体面积高出5-6倍,能平均分散人体重量的承受力,自动调节不良睡姿,健康令脊椎放松复原,从而具有矫形功能。

✓透气防菌:乳胶的分子结构特殊,具有良好的舒适性、透气性,抑制细菌及寄生虫的滋生;开放式的乳胶多孔气囊结构体,使空气在床垫中依然能自由流通,可分散睡眠中肌肤与床垫接触产生的热气、汗气、保持睡眠中的舒适干爽。

✓经久耐用:永不变形。

✓超静音:纯天然乳胶床垫能吸收因睡眠翻动,所造成的噪音及震动,使睡眠中不受干扰,不会影响睡伴,并能有效减少翻身次数,让您睡得更安稳香甜。

✓独立、舒适:每一寸乳胶床垫都是按人体结构设计:根据人体工程学原理,针对头、肩、背、腰、臀、腿、脚七个部位不同着力的要求,提供精准的对应支撑,保证身体重量被合理分散,令舒适感弥漫全身。

✓电版---生物学:乳胶床垫采用非金属部件,从而有力地阻止磁场的形成,做到完全绝缘和抗静电,100%的天然乳胶,拥有舒适自然的温和特性,无化学合成物,与肌肤接触不会产生不良的化学反应,高科技自然环保乳胶保证睡眠舒适健康。

海绵——普通海绵床垫(又叫泡绵)——记忆棉床垫记忆棉床垫通过特有的感温记忆粒子感知人体体温,提供舒适的支撑硬度;同时能够感知,记忆人体曲线,依照人体起伏完美塑型,服贴保护颈,腰,臀,腿部的自然弯曲。

不管仰卧还是侧卧,都能使人体各部位处于无压力状态,促进血液循环,缓解身体疲劳与酸痛,避免了传统床垫因为颈,腰部架空弯曲产生产疲劳感和落枕,使颈椎和脊椎得到完全的放松和休息,进而减少睡眠时不必要的翻身次数,减轻打鼾,肌肉酸痛等状况。

几种主要的床垫材料的主要性能相对对比(依次的顺序)使用寿命(高——低):山棕——椰棕、弹簧、乳胶——泡绵(海绵)透气性(强——弱):弹簧——山棕——椰棕——乳胶、泡绵(海绵)支撑性(好——差):山棕、椰棕——弹簧——乳胶——泡绵(海绵)抗干扰性(强——弱):山棕、椰棕——乳胶、泡绵——弹簧(海绵软硬程度(硬——软):山棕、椰棕——弹簧——乳胶、泡绵(海绵)人体贴合度(好——差):乳胶——泡绵(海绵)——弹簧——山棕、椰棕弹性(好——差):弹簧——乳胶、泡绵(海绵)——山棕——椰棕价位(高——低):乳胶——山棕——椰棕——弹簧——泡绵(海绵)现在流行几种材质相结合,综合几种材质的优点,常见的组合,例如:✓棕+弹簧:一面是棕材料(山棕或椰棕),一面是弹簧✓弹簧+乳胶✓棕+乳胶✓棕+海绵我们经营的床垫品牌✓欢颜:专业的山棕床垫品牌,多个系列,恩、培、喜、享,山棕与不同材质的组合✓雅兰:专业的弹簧床垫品牌,多个系列,例如公爵全弹簧床垫、新一代保健(半椰棕半弹簧)✓喜居乐(供应商环贸):泡绵、弹簧,多个产品系列,不同材质组合✓司麦尔:专业的椰棕床垫品牌✓麒麟(供应商喜来门):半椰棕半簧床垫,江浙沪地区知名品牌。

相关文档
最新文档