Customer Information - X-Flow AquaFlex TM Projection Tool

File name: 257049415.xls

Projection UF plant

AquaFlex 0.8mm V1.05Customer:Revision:

0.0

Project:Revision date:16-Oct-2006Lead nr:Designed by:Description:Checked by:

lym

Comments:

Currency:Euro

Watersource:Surface water

Acid CEB @ pH=2, Caustic CEB @ pH=12

XIGA 0.8 mm advised

Max Turbidity:20NTU Average Temp:

15

°C

Coagulant usage:Yes

type costs

[/l]

stock concentration

60[g/l as metal]

Requested:

Designed:Permeate

220.0m3/h Permeate

220.7m3/h (Overdesign: 0.3 %)

220.0m3/h

220.7m3/h Recovery 90.9%Feed 242.8m3/h

Nett flux

69.0lmh (40.6 gfd)

Unit design constraints:Unit design:Suggested

Actual

Max. nr. of modules per unit 24units

42Membrane area per module 40m2 (431 ft2)modules per unit

2040Number of units per feed pump 1Total number of modules 8080Maximum BW pump running time

80

%

Total area (m2)3,200

3,200

CEB wash-in to:Backwash waste

Process settings:Feed pump layout:

Suggested

Actual

2 feed pump(s) feeding 1 unit(s) each

Coagulant concentration 33[mg/l]

Gross flux 6580.5[lmh] (47.4 gfd)Backwash pump layout:

HC interval 15

30[min] 1 backwash pump(s) backwashing/cleaning 2 unit(s) each

CEB1:Interval

1211[h]Cleaning agent 1

NaOCl NaOCl [-] Working concentration 200250[mg/l] Stock concentration 150150[g/l] Costs

[/l]

Cleaning agent 2

NaOH NaOH [-] Working concentration 525600[mg/l] Stock concentration 319

300[g/l]

Costs [/l]CEB2:Interval

1312[h]Enter 0 for not executing CEB2

Cleaning agent 1

HCl HCl [-] Working concentration 450800[mg/l] Stock concentration 281

281

[g/l] Costs

[/l]Cleaning agent 2

[-] Working concentration [mg/l] Stock concentration [g/l] Costs [/l]Extra dead time

[sec/HC]

[min/day]

Chemical usage based on feedwater pH = 7 and alkalinity = 100 mg/l as CaCO3 unless stated otherwise

Net flux max 40.6 gfd, recovery minimum 90.9%. pretreated by coagulation, sedimentation, mediafilter and disc filters.

Jianghua

Kangping power plant