采暖通风空气调节系统自动控制

合集下载

常用英语-采暖通风与空气调节术语标准中英文对照

常用英语-采暖通风与空气调节术语标准中英文对照

采暖通风与空气调节术语标准中英文对照a orptance for solar radiation太阳辐射热吸收系数a orption equipment吸收装置a orption of gas and vapor气体吸收a orptiong refrige rationg cycle吸收式制冷循环a orption-type refrigerating machine吸收式制冷机acce door检查门acoustic a orptivity吸声系数actual de ity真密度actuating element执行机构actuator执行机构adaptive control system自适应控制系统additional factor for exterior door外门附加率additional factor for intermittent heating间歇附加率additional factor for wind force高度附加率additional heat lo 风力附加率adiabatic humidification附加耗热量adiabatic humidiflcation绝热加湿adsorbate吸附质adsorbent吸附剂adsorber吸附装置adsorption equipment吸附装置adsorption of gas and vapor气体吸附aerodynamic noise空气动力噪声aerosol气溶胶air balance风量平衡air changes换气次数air cha el风道air cleanline 空气洁净度air collector集气罐air conditioning空气调节air conditioning condition空调工况air conditioning equipment空气调节设备air conditioning machine room空气调节机房air conditioning system空气调节系统air conditioning system cooling load空气调节系统冷负荷air contaminant空气污染物air-cooled conde er风冷式冷凝器air cooler空气冷却器air curtain空气幕air cushion shock a orber空气弹簧隔振器air distribution气流组织air distributor空气分布器air-douche unit with water atomization喷雾风扇air duct风管、风道air filter空气过滤器air handling equipment空气调节设备air handling unit room空气调节机房air header集合管air humidity空气湿度air inlet风口air intake进风口air manifold集合管air opening风口air pollutant空气污染物air pollution大气污染air preheater空气预热器air return method回风方式air return mode回风方式air return through corridor走廊回风air ace空气间层air su ly method送风方式air su ly mode送风方式air su ly (suction) opening with slide plate插板式送(吸)风口air su ly volume per unit area单位面积送风量air temperature空气温度air through tu el地道风air-to-air total heat exchanger全热换热器air-to-cloth ratio气布比air velocity at work area作业地带空气流速air velocity at work place工作地点空气流速air vent放气阀air-water systen空气—水系统airborne particles大气尘air hater空气加热器air ace空气间层alarm signal报警信号ail-air system全空气系统all-water system全水系统allowed indoor fluctuation of temperature and relative humidity室内温湿度允许波动范围ambient noise环境噪声ammonia氨amplification factor of centrolled plant调节对象放大系数amplitude振幅anergy@angle of repose安息角ange of slide滑动角angle scale热湿比angle valve角阀a ual [value]历年值a ual coldest month历年最冷月a ual hottest month历年最热月anticorrosive缓蚀剂antifreeze agent防冻剂antifreeze agent防冻剂a aratus dew point机器露点a arent de ity堆积密度aqua-ammonia a orptiontype-refrigerating machine氨—水吸收式制冷机a iation ychrometer通风温湿度计A ma a iration ychrometer通风温湿度计atmo heric conde er淋激式冷凝器atmo heric diffusion大气扩散atmo heric dust大气尘atmo heric pollution大气污染atmo heric pre ure大气压力(atmo heric stability大气稳定度atmo heric tra arency大气透明度atmo heric turblence大气湍流automatic control自动控制automatic roll filter自动卷绕式过滤器automatic vent自动放气阀available pre ure资用压力average daily sol-air temperature日平均综合温度axial fan轴流式通风机azeotropic mixture refrigerant共沸溶液制冷剂Bback-flow preventer防回流装置back pre ure of steam trap凝结水背压力back pre ure return余压回水background noise背景噪声back plate挡风板bag filler袋式除尘器baghouse袋式除尘器barometric pre ure大气压力basic heat lo 基本耗热量hend muffler消声弯头bimetallic thermometer双金属温度计black globe temperature黑球温度blow off pipe排污管blowdown排污管boiler锅炉boiller house锅炉房boiler plant锅炉房boiler room锅炉房booster加压泵branch支管branch duct(通风) 支管branch pipe支管building envelope围护结构building flow zones建筑气流区building heating entry热力入口bulk de ity堆积密度bushing补心butterfly damper蝶阀by-pa damper空气加热器〕旁通阀by-pa pipe旁通管Ccanopy hood 伞形罩capillary tube毛细管capture velocity控制风速capture velocity外部吸气罩capturing hood 卡诺循环Carnot cycle串级调节系统cascade control system铸铁散热器cast iron radiator催化燃烧catalytic oxidation 催化燃烧ceilling fan吊扇ceiling panelheating顶棚辐射采暖center frequency中心频率central air conditionint system 集中式空气调节系统central heating集中采暖central ventilation system新风系统centralized control集中控制centrifugal compre or离心式压缩机entrifugal fan离心式通风机check damper(通风〕止回阀check valve止回阀chilled water冷水chilled water system with primary-secondary pum 一、二次泵冷水系统chimney(排气〕烟囱circuit环路circulating fan风扇circulating pipe循环管circulating pump循环泵clean room洁净室cleaning hole清扫孔cleaning vacuum plant真空吸尘装置cleanout opening清扫孔clogging capacity容尘量close ni le长丝closed booth大容积密闭罩closed full flow return闭式满管回水closed loop control闭环控制closed return闭式回水closed shell and tube conde er卧式壳管式冷凝器closed shell and tube evaporator卧式壳管式蒸发器closed tank闭式水箱coefficient of accumulation of heat蓄热系数coefficient of atmo heric tra areney大气透明度coefficient of effective heat emi ion散热量有效系数coficient of effective heat emi ion传热系数coefficient of locall resistance局部阻力系数coefficient of thermal storage蓄热系数coefficient of vapor蒸汽渗透系数coefficient of vapor蒸汽渗透系数coil盘管collection efficiency除尘效率combustion of gas and vapor气体燃烧comfort air conditioning舒适性空气调节common section共同段compe ator补偿器components(通风〕部件compre ion压缩compre ion-type refrigerating machine压缩式制冷机compre ion-type refrigerating system压缩式制冷系统compre ion-type refrigeration压缩式制冷compre ion-type refrigeration cycle压缩式制冷循环compre ion-type water chiller压缩式冷水机组concentratcd heating集中采暖concentration of narmful su tance有害物质浓度conde ate drain pan凝结水盘conde ate pipe凝结水管conde ate pump凝缩水泵conde ate tank凝结水箱conde ation冷凝conde ation of vapor气体冷凝conde er冷凝器conde ing pre ure冷凝压力conde ing temperature冷凝温度conde ing unit压缩冷凝机组conditioned ace空气调节房间conditioned zone空气调节区conical cowl锥形风帽co tant humidity system恒湿系统co tant temperature and humidity system恒温恒湿系统co tant temperature system 恒温系统co tant value control 定值调节co tant volume air conditioning system定风量空气调节系统continuous dust dislodging连续除灰continuous dust dislodging连续除灰continuous heating连续采暖contour zone稳定气流区control device控制装置control panel控制屏control valve调节阀control velocity控制风速controlled natural ventilation有组织自然通风controlled plant调节对象controlled variable被控参数controller调节器convection heating对流采暖convector对流散热器cooling降温、冷却(、)cooling air curtain冷风幕cooling coil冷盘管cooling coil section冷却段cooling load from heat传热冷负荷cooling load from outdoor air新风冷负荷cooling load from ventilation新风冷负荷cooling load temperature冷负荷温度cooling system降温系统cooling tower冷却塔cooling unit冷风机组cooling water冷却水correcting element调节机构correcting unit执行器correction factor for orientaion朝向修正率corrosion inhibitor缓蚀剂coupling管接头cowl伞形风帽criteria for noise control cro 噪声控频标准cro fan四通crro -flow fan贯流式通风机cro -ventilation穿堂风cut diameter分割粒径cyclone旋风除尘器cyclone dust separator旋风除尘器cylindrical ventilator筒形风帽Ddaily range日较差damping factot衰减倍数data scaning巡回检测days of heating period采暖期天数deafener消声器decibel(dB)分贝degree-days of heating period采暖期度日数degree of subcooling过冷度degree of superheat过热度dehumidification减湿dehumidifying cooling减湿冷却de ity of dust particle真密度derivative time微分时间design conditio 计算参数desorption解吸detecting element检测元件detention period延迟时间deviation偏差dew-point temperature露点温度dimond-shaped damper菱形叶片调节阀differential pre ure type flowmeter差压流量计diffuser air su ly散流器diffuser air su ly散流器送风direct air conditioning system 直流式空气调节系统direct combustion 直接燃烧direct-contact heat exchanger 汽水混合式换热器direct digital control (DDC) system 直接数字控制系统direct evaporator 直接式蒸发器direct-fired lithiumbromide a orption-type refrigerating machine 直燃式溴化锂吸收式制冷机direct refrigerating system 直接制冷系统direct return system 异程式系统direct solar radiation 太阳直接辐射discharge pre ure 排气压力discharge temperature 排气温度di ersion 大气扩散district heat su ly 区域供热district heating 区域供热disturbance frequency 扰动频率dominant wind direction 最多风向double-effect lithium-bromide a orption-type refigerating machine 双效溴化锂吸收式制冷机double pipe conde er 套管式冷凝器down draft 倒灌downfeed system 上分式系统dow tream ray pattern 顺喷drain pipe 泄水管drain pipe 排污管droplet 液滴drv air 干空气dry-and-wet-bulb thermometer 干湿球温度表dry-bulb temperature 干球温度dry cooling condition 干工况dry dust separator 干式除尘器dry expa ion evaporator 干式蒸发器dry return pipe 干式凝结水管dry steam humidifler 干蒸汽加湿器dualductairconing ition 双风管空气调节系统dual duct system 双风管空气调节系统duct 风管、风道dust 粉尘dust capacity 容尘量dust collector 除尘器dust concentration 含尘浓度dust control 除尘dust-holding capacity 容尘量dust removal 除尘dust removing system 除尘系统dust sampler 粉尘采样仪dust sampling meter 粉尘采样仪dust separation 除尘dust separator 除尘器dust source 尘源dynamic deviation动态偏差Eeconomic resistance of heat tra fer经济传热阻economic velocity经济流速efective coefficient of local resistance折算局部阻力系数effective legth折算长度effective stack height烟囱有效高度effective temperature difference送风温差ejector喷射器ejetor弯头elbow电加热器electric heater电加热段electric panel heating电热辐射采暖electric precipitator电除尘器electricradian theating 电热辐射采暖electricresistance hu-midkfier电阻式加湿器electro- eumatic convertor电—气转换器electrode humidifler电极式加湿器electrostatic precipi-tator电除尘器eliminator挡水板emergency ventilation事故通风emergency ventilation system事故通风系统emi ion concentration排放浓度enclosed hood密闭罩enthalpy焓enthalpy control system新风〕焓值控制系统enthalpy entropy chart焓熵图entirely ventilation全面通风entropy熵environmental noise环境噪声equal percentage flow characteristic等百分比流量特性equivalent coefficient of local resistance当量局部阻力系数equivalent length当量长度equivalent[continuous A] sound level等效〔连续A〕声级evaporating pre ure蒸发压力evaporating temperature蒸发温度evaporative conde er蒸发式冷凝器evaporator蒸发器exce heat余热exce pre ure余压exce ive heat 余热cxergy@exhaust air rate排风量exhaust fan排风机exhaust fan room排风机室exhaust hood局部排风罩exhaust inlet吸风口exhaust opening吸风口exhaust opening orinlet风口exhaust outlet排风口exaust vertical pipe排气〕烟囱exhausted enclosure密闭罩exit排风口expa ion膨胀expa ion pipe膨胀管explosion proofing防爆expa ion steam trap恒温式疏水器expa ion tank膨胀水箱extreme maximum temperature极端最高温度extreme minimum temperature极端最低温度Ffabric collector袋式除尘器face tube皮托管face velocity罩口风速fan通风机fan-coil air-conditioning system风机盘管空气调节系统fan-coil system风机盘管空气调节系统fan-coil unit风机盘管机组fan house通风机室fan room通风机室fan section风机段feed-forward control前馈控制feedback反馈feeding branch tlo radiator散热器供热支管fibrous dust纤维性粉尘fillter cylinder for sampling滤筒采样管fillter efficiency过滤效率fillter section过滤段filltration velocity过滤速度final resistance of filter过滤器终阻力fire damper防火阀fire prevention防火fire protection防火fire-resisting damper防火阀fittings(通风〕配件fixed set-point control定值调节fixed su ort固定支架fixed time temperature (humidity)定时温(湿)度flame combustion热力燃烧flash gas闪发气体flash steam二次蒸汽flexible duct软管flexible joint柔性接头float type steam trap浮球式疏水器float valve浮球阀floating control无定位调节flooded evaporator满液式蒸发器floor panel heating地板辐射采暖flow capacity of control valve调节阀流通能力flow characteristic of control valve调节阀流量特性foam dust separator泡沫除尘器follow-up control system随动系统forced ventilation机械通风forward flow zone射流区foul gas不凝性气体four-pipe water system四管制水系统fractional separation efficiency分级除尘效率free jet自由射流free sillica游离二氧化硅free silicon dioxide游离二氧化硅freon氟利昂frequency interval频程frequency of wind direction风向频率fresh air handling unit新风机组resh air requirement新风量friction factor摩擦系数friction lo 摩擦阻力frictional resistance摩擦阻力fume烟〔雾〕fumehood排风柜fumes烟气Ggas-fired infrared heating 煤气红外线辐射采暖gas-fired unit heater 燃气热风器gas purger 不凝性气体分离器gate valve 闸阀general air change 全面通风general exhaust ventilation (GEV) 全面排风general ventilation 全面通风generator 发生器global radiation总辐射grade efficiency分级除尘效率granular bed filter颗粒层除尘器granulometric distribution粒径分布gravel bed filter颗粒层除尘器gravity separator沉降室ground-level concentration落地浓度guide vane导流板Hhair hygrometor毛发湿度计hand pump手摇泵harmful gas andvapo有害气体harmful su tance有害物质header分水器、集水器(、)heat and moisture热湿交换tra fer热平衡heat conduction coefficient导热系数heat conductivity导热系数heat distributing network热网heat emitter散热器heat endurance热稳定性heat exchanger换热器heat flowmeter热流计heat flow rate热流量heat gain from lighting设备散热量heat gain from lighting照明散热量heat gain from occupant人体散热量heat i ulating window保温窗heat(thermal)i uation隔热heat(thermal)lag延迟时间heat lo 耗热量heat lo by infiltration冷风渗透耗热量heat-operated refrigerating system热力制冷系统heat-operated refrigetation热力制冷heat pipe热管heat pump热泵heat pump air conditioner热泵式空气调节器heat release散热量heat resistance热阻heat screen隔热屏heat shield隔热屏heat source热源heat storage蓄热heat storage capacity蓄热特性heat su ly供热heat su ly network热网heat tra fer传热heat tra mi ion传热heat wheel转轮式换热器heated thermometer anemometer热风速仪heating采暖、供热、加热(、、)heating a liance采暖设备heating coil热盘管heating coil section加热段heating equipment采暖设备heating load热负荷heating medium热媒heating medium parameter热媒参数heating pipeline采暖管道heating system采暖系统heavy work重作业high-frequency noise高频噪声high-pre ure ho twater heating高温热水采暖high-pre ure steam heating高压蒸汽采暖high temperature water heating高温热水采暖hood局部排风罩horizontal water-film syclonet卧式旋风水膜除尘器hot air heating热风采暖hot air heating system热风采暖系统hot shop热车间hot water boiler热水锅炉hot water heating热水采暖hot water system热水采暖系统hot water pipe热水管hot workshop热车间hourly cooling load逐时冷负荷hourly sol-air temperature逐时综合温度humidification加湿humidifier加湿器humididier section加湿段humidistat恒湿器humidity ratio含湿量hydraulic calculation水力计算hydraulic disordeer水力失调hydraulic dust removal水力除尘hydraulic resistance balance阻力平衡hydraulicity水硬性hydrophilic dust亲水性粉尘hydrophobic dust疏水性粉尘Iimpact dust collector冲激式除尘器impact tube皮托管impedance muffler阻抗复合消声器inclined damper斜插板阀index circuit最不利环路indec of thermal inertia (valueD)热惰性指标(D值)indirect heat exchanger表面式换热器indirect refrigerating sys间接制冷系统indoor air design conditio 室内在气计算参数indoor air velocity室内空气流速indoor and outdoor design conditio 室内外计算参数indoor reference for air temperature and relative humidity室内温湿度基数indoor temperature (humidity)室内温(湿)度induction air-conditioning system诱导式空气调节系统induction unit诱导器inductive ventilation诱导通风industral air conditioning工艺性空气调节industrial ventilation工业通风inertial dust separator惯性除尘器infiltration heat lo 冷风渗透耗热量infrared humidifier红外线加湿器infrared radiant heater红外线辐射器inherent regulation of controlled plant调节对象自平衡initial concentration of dust初始浓度initial resistance of filter过滤器初阻力imput variable输入量i ulating layer保温层integral enclosure整体密闭罩integral time积分时间interlock protection联锁保护intermittent dust removal定期除灰intermittent heating间歇采暖inversion layer逆温层inverted bucket type steam trap倒吊桶式疏水器irradiance辐射照度isoenthalpy等焓线isobume等湿线isolator隔振器isotherm等温线isothermal humidification等温加湿isothermal jet等温射流Jjet射流jet axial velocity射流轴心速度jet divergence angle射流扩散角jet in a confined ace受限射流Kkatathermometer卡他温度计Llaboratory hood排风柜lag of controlled plant调节对象滞后large ace enclosure大容积密闭罩latent heat潜热lateral exhaust at the edge of a bath槽边排风罩lateral hoodlength of pipe section侧吸罩length of pipe section管段长度light work轻作业limit deflection极限压缩量limit switch限位开关limiting velocity极限流速linear flow characteristic线性流量特性liquid-level gage液位计liquid receiver贮液器lithium bromide溴化锂lithium-bromide a orption-type refrigerating machine溴化锂吸收式制冷机lithium chloride resistance hygrometer氯化锂电阻湿度计load pattern负荷特性local air conditioning局部区域空气调节local air su iy system局部送风系统local exhaustventilation (LEV)局部排风local exhaust system局部排风系统local heating局部采暖local relief局部送风local relief system局部送风系统local resistance局部阻力local solartime地方太阳时local ventilation局部通风local izedairsu ly for air-heating集中送风采暖local ized air control就地控制loop环路louver百叶窗low-frequencynoise低频噪声low-pre ure steam heating低压蒸汽采暖lyophilic dust亲水性粉尘lyophobic dust疏水性粉尘Mmain 总管、干管main duct通风〕总管、〔通风〕干管main pipe总管、干管make-up water pump补给水泵manual control手动控制ma concentration质量浓度maximum allowable concentration (MAC)最高容许浓度maximum coefficient of heat tra fer最大传热系数maximum depth of frozen ground最大冻土深度maximum sum of hourly colling load逐时冷负荷综合最大值mean a ual temperature (humidity)年平均温(湿)度mean a ual temperature (humidity)日平均温(湿)度mean daily temperature (humidity)旬平均温(湿)度mean dekad temperature (humidity)月平均最高温度mean monthly maximum temperature月平均最低温度mean monthly minimum temperature月平均湿(湿)度mean monthly temperature (humidity)平均相对湿度mean relative humidity平均风速emchanical air su ly system机械送风系统mechanical and hydraulic联合除尘combined dust removal机械式风速仪mechanical anemometer机械除尘mechanical cleaning off dust机械除尘mechanical dust removal机械排风系统mechanical exhaust system机械通风系统mechanical ventilation机械通风media velocity过滤速度metal radiant panel金属辐射板metal radiant panel heating金属辐射板采暖micromanometer微压计micropunch plate muffler微穿孔板消声器mid-frequency noise中频噪声middle work中作业midfeed system中分式系统minimum fresh air requirmente最小新风量minimum resistance of heat tra fer最小传热阻mist雾mixing box section混合段modular air handling unit组合式空气调节机组moist air湿空气moisture exce 余湿moisure gain散湿量moisture gain from a liance and equipment设备散湿量moisturegain from occupant人体散湿量motorized valve电动调节阀motorized ( eumatic)电(气)动两通阀-way valvemotorized ( eumatic)-way valve电(气)动三通阀movable su ort活动支架muffler消声器muffler section消声段multi-operating mode automtic conversion工况自动转换multi-operating mode control system多工况控制系统multiclone多管〔旋风〕除尘器multicyclone多管〔旋风〕除尘器multishell conde er组合式冷凝器Nnatural and mechanical combined ventilation联合通风natural attenuation quantity of noise噪声自然衰减量natural exhaust system自然排风系统natural freguency固有频率natural ventilation自然通风NC-curve[s]噪声评价NC曲线negative freedback负反馈neutral level中和界neutral pre ure level中和界neutral zone中和界noise噪声noise control噪声控制noise criter ioncurve(s)噪声评价NC曲线noisc rating number噪声评价NR曲线noise reduction消声non azeotropic mixture refragerant非共沸溶液制冷剂non-commo ection非共同段non conde able gas 不凝性气体non conde able gas purger不凝性气体分离器non-isothermal jet非等温射流nonreturn valve通风〕止回阀normal coldest month止回阀normal coldest month累年最冷月normal coldest -month period累年最冷三个月normal hottest month累年最热月(3)normal hottest month period累年最热三个月normal three summer months累年最热三个月normal three winter months累年最冷三个月normals累年值nozzle outlet air su luy喷口送风number concentration计数浓度number of degree-day of heating period采暖期度日数Ooctave倍频程/ octave倍频程octave band倍频程oil cooler油冷却器oill-fired unit heater燃油热风器one-and-two pipe combined heating system单双管混合式采暖系统one (single)-pipe circuit (cro -over) heating system单管跨越式采暖系统one(single)-pipe heating system单管采暖系统e(single)-pipe loop circuit heating system水平单管采暖系统one(single)-pipe seriesloop heating system单管顺序式采暖系统one-third octave band倍频程on-of control双位调节open loop control开环控制open return开式回水open shell and tube conde er立式壳管式冷凝器open tank开式水箱operating pre ure工作压力operating range作用半径o osed multiblade damper对开式多叶阀organized air su ly有组织进风organized exhaust有组织排风organized natural ventilation有组织自然通风outdoor air design conditio 室外空气计算参数outdoor ctitcal air temperature for heating采暖室外临界温度outdoor design dry-bulb temperature for summer air conlitioning夏季空气调节室外计算干球温度outdoor design hourly temperature for summer air conditioning夏季空气调节室外计算逐时温度outdoor design mean daily temperature for summer air conditioning夏季空气调节室外计算日平均温度outdoor design relative humidityu for summer ventilation夏季通风室外计算相对湿度outdoor design relative humidity for winter air conditioning冬季空气调节室外计算相对湿度outdoor design temperature ture for calculated envelope in winter冬季围护结构室外计算温度outdoor design temperature ture for heating采暖室外计算温度outdoor design temperature for summer ventilation夏季通风室外计算温度outdoor design temperature for winter air conditioning冬季空气调节室外计算温度outdoor design temperature for winter vemtilation冬季通风室外计算温度outdoor designwet-bulb temperature for summer air conditioning夏季空气调节室外计算湿球温度outdoor mean air temperature during heating period采暖期室外平均温度outdoor temperature(humidity)室外温(湿)度outlet air velocity出口风速out put variable输出量overall efficiency of separation除尘效率overall heat tra mi ion coefficient传热系数ouvrflow pipe溢流管overheat steam过热蒸汽overla ing averages滑动平均overshoot超调量Ppackaged air conditioner整体式空气调节器packaged heat pump热泵式空气调节器packed column填料塔packed tower填料塔panel heating辐射采暖parabolic flow character抛物线流量特性isticparallel multiblade damperin平行式多叶阀parameter detection参数检测part通风〕部件partial enclosure局部密闭罩partial pre ure of water vapor水蒸汽分压力particle粒子particle counter粒子计数器particle number concentration计数浓度particle size粒径particle size distribution粒径分布particulate粒子particulate collector除尘器particulates大气尘pa age ventilating duct通过式风管penetration rate穿透率percentage of men,women and children群集系数and childre ercentage of po ible su hine日照率percentage of return air 回风百分比cerforated ceiling air su yl孔板送风perforated plate tower筛板塔periodic dust dislodging定期除灰piece(通风〕部件pipe fittings管道配件pipe radiator光面管散热器pipe section管段pipe coil光面管放热器pitot tube皮托管plate heat exchanger板式换热器plenum chamber静压箱plenum ace稳压层plug丝堵plume烟羽plume rise height烟羽抬升高度C-curve[s]噪声评价C曲线eumatic conveying气力输送pueumatic tra ort气力输送eumatic valve气动调节阀eumo-electrical convertor气-电转换器positioner定位器positive feedback正反馈powerroof ventilator屋顶通风机preferred noise criteria curve[s]噪声评价C曲线pre ure drop压力损失pre ure enthalpy chart压焓图pre ure gage压力表pre ure of steam su ly供汽压力pre ure reducing valve减压阀pre ure relief device泄压装置pre ure relief valve安全阀pre ure thermometer压力式温度计pre ure volume chart压容图primary air fan-coil system风机盘管加新风系统primary air system新风系统primary retirn air一次回风proce air conditioning工艺性空气调节program control程序控制proportional band比例带proportional control比例调节proportional-integral (PI)control比例积分调节proportional-integralderivative(PID)control比例积分微分调节protected(roof)monitor避风天窗ychrometric chart声级计pulvation action干湿球温度表push-pull hood焓湿图pulvation action尘化作用push-pull hood吹吸式排风罩Qquick open flow characteristic快开流量特性Rradiant heating辐射采暖radiant inte ity辐射强度sadiation inte ity辐射强度radiator散热器radiator heating散热器采暖radiator heating system散热器采暖系统radiator valve散热器调节阀rating under air conditioning condition空调工况制冷量rcactive muffler抗性消声器receiver贮液器receiving hood接受式排风罩reciprocating compre or活塞式压缩机recirculation cavety空气动力阴影区recording thermometer自记温度计reducing coupling异径管接头reducing valve减压阀reentrainment of dust 二次扬尘refrigerant制冷剂[refrigerating] coefficient of performance (COP)(制冷〕性能系数refrigerating compre or制冷压缩机refrigerating cycle制冷循环refrigerating effect制冷量refrigerating engineering制冷工程refrigerating machine制冷机refrigerating medium载冷剂refrigerating planttoom制冷机房refrigerating station制冷机房refrigerating system制冷系统refrigeration 制冷regenerative noise再生噪声register百叶型风口regulator调节器reheat air conditioning system再热式空气调节系统relative humidity相对湿度relay继电器remote control遥控resistance of heat tra fer传热阻resistance thermometer电阻温度计resistance to water vapor permeability蒸汽渗透阻resistance to water vapor permeation蒸汽渗透阻resistive muffler阻性消声器resistivity比电阻resonance共振resonant frequency共振频率re o e curve of controlled plant调节对象正升曲线teturn air回风return air inlet回风口return branch of radiator散热器回水支管return fan回风机return flow zone回流区return water temperataure回水温度reverse Carnot cycle逆卡诺循环reversed return system同程式系统reversible cycle可逆循环rim exhaust槽边排风罩rim ventilation槽边通风riser立管roof ventilator筒形风帽room a orption房间吸声量room air conditioner房间空气调节器rotameter转子流量计rotary dehumidifier转轮除湿机rotary heat exchanger转轮式换热器rotary su ly outlet旋转送风口rotating air outlet with movable guide vanes旋转送风口roughne factor相对粗糙度ru er shock a orber橡胶隔振器ru ing mea 滑动平均Ssafety valve安全阀samling hole测孔sampling port测孔saturated steam饱和蒸汽saturation humidity ratio饱和含湿量screw compre or螺杆式压缩机screwni le丝对screwed plug丝堵scondary refrigerant载冷剂secondary return air二次回风selective control system选择控制系统selector选择器self-contained cooling unit冷风机组self learning system自学习系统se ible cooling等湿冷却se ible heat显热se ible heating等湿加热se ing element敏感元件se or传感器sequence control程序控制set point给定值settling chamber沉降室setting velocity沉降速度shading coefficient遮阳系数shell and coil conde er壳管式冷凝器shell and tube conde er 壳管式冷凝器shell and tube evaporator壳管式蒸发器sholder ni le长丝shutter百叶窗sidehood侧吸罩sidewall air su ly侧面送风sieve-plate column筛板塔single duct air conditioning system单风管空气调节系统single duct system单风管空气调节系统single-effect lithiumbromide a orption-type refrigerating machine单效溴化锂吸收式制冷机sky radiation天空散射辐射slide damper插板阀sling ychrometer通风温湿度计slip rate穿透率slip diffuser条缝型风口slip exhaust hood槽边排风罩slot exhaust on edges of tanks槽边通风slot outlet条缝型风口sludge handling泥浆处理smoke烟〔尘〕smoke control防烟smoke damper防烟阀smoke exhaust damper排烟阀smoke extraction排烟smoke plume烟羽smokeproof damper防烟阀sol-air temperature综合温度solar altitude太阳高度角solar azimuth太阳方位角solar co tant太阳常数solar declination太阳赤纬solar heating太阳能采暖solar irradiance太阳辐射照度solar radiant heat太阳辐射热solar radiation太阳辐射solenoid valve电磁阀sound a orber消声器sound a orption吸声sound a orption coefficient吸声系数sound a orption material吸声材料sound attenuation消声sound deadening消声sound deadening capacity消声量sound i ulation隔声sound inte ity level声强级sound level声级sound level meter声级计sound power level声功率级sound pre ure level声压级sound source声源source of heat release散热源ace air diffusion气流组织ace cooling load房间冷负荷ace heat gain房间得热量ace heating采暖ace moisture load房间湿负荷ace temperature variation区域温差ecific enthalpy比焓ecific frictional resistance比摩阻ecific gas flow rate气布比ecific heat load散热强度ecific resistance比电阻i ing disk humidifier离心式加湿器lit air conditioning system分体式空气调节器lit ranging control control分程控制litter导流板ot temperature工作地点温度ray chamber喷水段ray fan喷雾风扇ray nozzle喷嘴ray nozzle de ity喷嘴密度ray-type air washer section喷水段ray-type evaporator喷淋式蒸发器read射流扩散角ring shock a orber弹簧隔振器stability稳定性stack(排气〕烦囱stack effect pre ure热压standard condition标准工况standard rating[of refrigerating machine]标准制冷量standby heating值班采暖static deflection静态压缩量static deflection静态偏差static pre ure静压steady-state heat tra fer稳态传热steam boiler蒸汽锅炉steame ejector蒸汽喷射器steam header分汽缸steam heating蒸汽采暖steam heating system蒸汽采暖系统steam-jet xot water heating system蒸汽喷射热水采暖系统steam jet refrigerating蒸汽喷射式制冷机machinesteam jet refrigeration cycle蒸汽喷射式制冷循环steam manifold分汽缸steam pipe蒸汽管steam trap疏水器steam-water mixed heat exchanger汽-水混合式换热器steam water mixture汽水混合物steam-water type heat exchanger汽-水式换热器steel radiator钢制散热器stop valve截止阀stove heating火炉采暖strainer除污器strantiicated air conditioning分层空气调节strip radiant panel带状辐射板strong liquor浓溶液。

采暖通风与空气调节设计规范(GBJ19-87)

采暖通风与空气调节设计规范(GBJ19-87)

中华人民共和国国家标中华人民共和国国家标准采暖通风与空气调节设计规范GBJ19—87中华人民共和国国家标准采暖通风与空气调节设计规范GBJ19—87主编部门:中国有色金属工业总公司批准部门:中华人民共和国国家计划委员会实行日期:1988年8月1日关于发布《采暖通风与空气调节设计规范》的通知计标〔1987〕2480号根据原国家建委(81)建发设字第546号文的通知,由中国有色金属工业总公司,会同有关部门共同修订《工业企业采暖通风和空气调节设计规范》TJ19—75,已经有关部门会审。

现批准修订后的《采暖通风与空气调节设计规范》GBJ19—87为国家标准,自1988年8月1日起施行,原《工业企业采暖通风和空气调节设计规范》TJ19—75同时废止。

国家计划委员会1987年12月30日修订说明本规范是根据原国家建委(81)建发设字第546号文的通知要求,由中国有色金属工业总公司负责主编,具体由北京有色冶金设计研究总院,会同国内有关设计、科研和高等院校等17个单位,对原《工业企业采暖通风和空气调节设计规范》TJ19—75(试行)进行修订而成的。

在修订过程中,修订组进行了比较广泛深入的调查研究,总结了国内实践经验,吸取了近年来有关的科研成果,查阅了国内外大量资料,借鉴了国外同类技术中符合我国实际的内容,多次征求了全国各有关单位以及香港地区的意见,对其中一些重要问题进行了专题研究和反复讨论,最后召开了全国审查会议,会同各有关部门共同审查定稿。

本规范共分八章和十三个附录,主要内容有:总则、室内外计算参数、采暖、通风、空气调节、制冷、自动控制和消声与隔振等。

在执行本规范过程中,请各单位注意总结经验,积累资料,如发现需要修改和补充之处,请将意见和有关资料寄北京有色冶金设计研究总院暖通规范管理组(北京复兴路12号),以便今后修订时参考。

中国有色金属工业总公司1987年12月主要符号A——声级;矩形送风口边长a——围护结构温差修正系数;紊流系数B——距离;矩形送风口边长b——指数;系数C——静风;有效热压差与有效风压差之比;系数c f——风压系数C L——逐时冷负荷c p——空气的定压比热容c r——热压系数D——围护结构热惰性指标;直径d g——工作地点的宽度d——含湿量d o——送风口的直径d s——送至工作地点的气流宽度E——东;东风F,f——面积F o——送风口的有效截面积F j——进风口面积F p——排风口面积G——通风量G j——进风量G p——排风量g——重力加速度H——高度;水平h——高度;计算门窗的中心线标高;高差h j——进风口中心与中和界的高差h p——排风口中心与中和界的高差h z——中和界标高I——焓J——太阳总辐射照度J p——太阳总辐射照度的日平均值K——传热系数;安全系数L——风量;空气量l——门窗缝隙计算长度m——散热量有效系数;渗透冷空气量的综合修正系数m1,m2,m3——系数N——北;北风n——建筑物的楼层数;渗透冷空气量的朝向修正系数P——电动机功率P n——电动机轴功率△P——系统总压力损失△P min——调节阀全开时的压力损失Q——散热量;显热量;耗热量Q f——辐射散热量R o——围护结构传热阻R o·min——围护结构的最小传热阻R j——围护结构本体的热阻R n——围护结构内表面换热阻R w——围护结构外表面换热阻S——压力损失比;南;南风;距离s——净距t o——送风口的出口温度t d——屋顶下的温度t g——工作地点温度t1——露点温度t1p——累年最冷月平均温度t1s——邻室计算平均温度t max——累年极端最高温度t n,t n′——分别为室内计算温度和竖井计算温度t np——室内平均温度t p——排风温度t p·min——累年最低日平均温度t rp——累年最热月平均温度t sh——夏季空气调节室外计算逐时温度t s·max——与累年极端最高温度和最热月平均相对湿度相对应的湿球温度t s·rp——与累年最热月平均温度和平均相对湿度相对应的湿球温度t w——围护结构室外计算温度t wf——夏季通风室外计算温度t wg——夏季空气调节室外计算干球温度t wk——冬季空气调节室外计算温度t wl——逐时冷负荷计算温度t wn——采暖室外计算温度t wp——夏季空气调节室外计算日平均温度t ws季空气调节室外计算湿球温度t zp季空气调节室外计算日平均综合温度t zs季空气调节室外计算逐时综合温度△t H温度梯度△t1s计算平均温度与室外计算日平均温度之差△t r夏季室外计算平均日较差△t y室内计算温度与围护结构内表面温度的允许温差v o冬季室外平均风速;送风口的出口风速Vg——工作地点平均风速W——西;西风Z——距离α——系数αn—围护结构内表面换热系数αw—围护结构外表面换热系数β——夏季室外温度逐时变化系数ξj—进风口的局部阻力系数ξr—排风口的局部阻力系数ρ——围护结构外表面对于太阳辐射热的吸收系数ρnp——室内空气的平均密度ρp——排风温度下的空气密度ρw i通风室外计算温度下的空气密度ρwn采暖室外计算温度下的空气密度目录第一章总则第二章室内外计算参数第一节室内空气计算参数第二节室外空气计算参数第三节夏季太阳辐射照度第三章采暖第一节一般规定第二节热负荷第三节散热器采暖第四节辐射采暖第五节热风采暖与热风幕第六节采暖管道第七节蒸汽喷射器第四章通风第一节一般规定第二节自然通风第三节隔热降温第四节机械通风第五节除尘与净化第六节防火与防爆第七节设备、风管及其他第五章空气调节第一节一般规定第二节负荷计算第三节系统设计第四节气流组织第五节空气处理第六章制冷第一节一般规定第二节压缩式制冷第三节热力制冷第四节机房设计、设备布置及其他第七章自动控制第一节一般规定第二节检测、联锁与信号显示第三节自动调节与控制第四节制冷装置的自动保护与控制第八章消声与隔振第一节一般规定第二节消声与隔声第三节隔振附录一名词解释附录二室外气象参数附录三室外计算温度的简化统计方法附录四夏季太阳总辐射照度附录五夏季透过标准窗玻璃的太阳辐射照度附录六夏季空气调节大气透明度分布图附录七加热由门窗缝隙渗入室内的冷空气的耗热量附录八渗透冷空气量的朝向修正系数n值附录九自然通风的计算附录十系统式局部送风的计算附录十一除尘风管的最小风速附录十二法定计量单位与习用非法定计量单位换算表附录十三本规范用词说明附加说明第一章总则第1·0·1条为了在采暖、通风和空气调节设计中,体现艰苦奋斗、勤俭建国精神,贯彻国家现行的有关方针政策,以便为安全生产、改善生活和劳动条件、节约能源、保护环境、保证产品质量和提高劳动生产率提供必要的条件,特制订本规范。

采暖通风与空气调节术语标准

采暖通风与空气调节术语标准

采暖通风与空气调节术语标准采暖通风与空气调理术语规范GB50155-92主编部门:中国有色金属工业总公司同意部门:中华人民共和国树立部实施日期:1992年10月1日关于发布国度规范«采暖通风与空气调理术语规范»的通知建标〔1992〕181号依据国度计委计综305号文的要求,由中国有色金属工业总公司会同有关部门共同制定的«采暖通风与空气调理术语规范»,曾经有关部门会审,现同意«采暖通风与空气调理术语规范»GB50155—92为强迫性国度规范,自1992年10月1日起实施。

本规范由中国有色金属工业总公司担任管理,详细解释等任务由中国有色金属工业总公司北京有色冶金设计研讨总院担任,出版发行由树立部规范定额研讨所担任组织。

中华人民共和国树立部1992年4月2日编制说明本规范是依据原国度建委(82)树立字20号文«关于编制工程树立有关专业名词、术语规范的通知»要求,由中国有色金属工业总公司担任主编,详细由北京有色冶金设计研讨总院,会同国际有关科研、设计等单位共同编制的。

编制进程中,编制组停止了普遍深化的调查研讨,搜集和查阅了国际外少量资料,自创了国外同类规范中有用的局部,屡次征求了全国各有关单位以及香港地域的意见,对其中一些疑问效果停止了专题研讨和重复讨论,在全国范围内停止了函审,最后召开了审定会,会同各有关部门共同审查定稿。

本规范共分9章35节,收录常用术语1001条,其主要内容包括:总那么、室内外计算参数、采暖、通风、空气调理、制冷、自动控制、消声与隔振、检测仪表及其他等。

鉴于本规范是新编的,在执行进程中,请各单位留意总结阅历,积聚资料,如发现需求修正和补充之处,请将意见和有关资料寄北京有色冶金设计研讨总院暖通规范管理组(北京复兴路12号,邮政编码100038),以便今后修订时参考。

1991年6月第一章总那么第1.0.1条为一致采暖通风与空气调理工程的术语及其释义,完成专业术语的规范化,以利于国际外技术交流,促进采暖通风与空气调理技术的开展,特制定本规范。

空气调节自动化控制系统

空气调节自动化控制系统

空气调节自动化控制系统
随着科技的发展和社会经济的不断发展,人们的生活质量要求越来越高。

空气环境质量已成为社会人们关注的焦点,空气调节系统作为人工干预空气环境质量的重要手段,如何提高其效率及运行质量,是当前急需解决的问题。

一、空气调节自动化控制系统的概述
空气调节自动化控制系统采用自动化技术,能够实现空气调节系统的自动化控制,很大程度的提高了空气调节系统的效率及运行质量,为人们打造一个更加舒适、安全、可靠的空气环境。

二、空气调节自动化控制系统的优势
1.提高效率
采用自动化控制技术,实现空气调节系统的自动化控制,无需人工参与,减小了人工操作误差的可能性,提高了系统效率和运行质量。

2. 降低人工成本
自动化控制技术不仅提高了空气调节系统的效率,同时还降低了人工成本。

采用自动化控制手段,节省了人力资源,减轻人工负担,实现机器代替人工,可以避免人为操作误差的发生,提升空气调节系统的运行效率,减少维修成本。

3.提高能效
空气调节自动化控制系统可结合能源管理系统,实现对设备的数据
采集和分析,有效提高整体能效,降低运行成本,达到降低能源消耗
的效果。

4.提高稳定性
空气调节自动化控制系统采用智能自动控制技术,并配合相应的传
感器、仪表等设备,能够实现对空气质量、温度、湿度等参数的自动
监测和调整,从而保证系统的稳定性和运行安全性。

三、总结
空气调节自动化控制系统作为一种新兴的节能环保技术,已经逐渐
成为现代智能空调系统的重要组成部分。

在未来的发展中,我们相信,空气调节自动化控制系统将更加完善和智能化,发挥更大的作用,为
人们打造一个更加舒适、安全、可靠的环境。

民用建筑供暖通风与空气调节设计监测与控制

民用建筑供暖通风与空气调节设计监测与控制

民用建筑供暖通风与空气调节设计监测与控制【1】一般规定1、采暖、通风与空气调节系统应设置监测与控制系统,并应符合以下规定:(1)监测与控制内容可包括参数检测、参数与设备状态显示、自动调节与控制、工况自动转换、设备联锁与自动保护、能量计量以及中央监控与管理等。

具体内容应根据建筑物的功能与标准、系统类型、设备运行时间以及工艺对管理的要求等因素,通过技术经济比较确定;(2)系统规模大,制冷空气调节设备台数多且相关联各部分相距较远时,应采用集中监控系统;(3)不具备采用集中监控系统的采暖、通风和空气调节系统,宜采用就地的自动控制系统:2、采暖通风与空气调节设备设置联动、联锁等保护措施时,应符合下列规定:(1)当采用集中监控系统时,联动、联锁等保护措施应由集中监控系统实现;(2)当采用就地自动控制系统时,联动、联锁等保护措施,应为自控系统的一部分或独立设置;(3)当无集中监控或就地自动控制系统时,设置专门联动、联锁等保护措施。

3、采用集中监控系统控制的动力设备,应设就地手动控制装置,并通过远动/手动转换开关实现自动与就地手动控制的转换;自动/手动转换开关的状态应为集中监控系统的输入参数之一。

4、控制器宜安装在被控系统或设备附近,当采用集中监控系统时,应设置控制室;当就地控制系统环节及仪表较多时,宜设置控制室。

5、涉及防火与排烟系统的监测与控制,应执行国家现行有关防火规范的规定;与防排烟系统合用的通风空气调节系统应按消防设置的要求供电,并在火灾时转入火灾控制状态;通风空气调节风道上宜设置带位置反馈的防火阀。

6、热源、热力站和制冷机房的燃料消耗量、补水量、耗电量均应计量。

循环水泵耗电量宜单独计量。

7、中央级监控管理系统应符合下列要求:(1)应能以与现场测量仪表相同的时间间隔与测量精度连续记录、显示各系统运行参数和设备状态。

其存储介质和数据库应能保证记录连续一年以上的运行参数;(2)应能计算和定期统计系统的能量消耗、各台设备连续和累计运行时间;(3)应能改变各控制器的设定值,并依据节能控制程序自动进行系统或设备的启停;(4)应设立权限控制等安全机制,并宜设置可与其它弱电系统数据共享的集成接口;(5)应有参数越线报警、事故报警及报警记录功能,并宜设有系统或设备故障诊断功能。

制冷设计规范

制冷设计规范

制冷设计规范第一节一般规定第6.1.1条空气调节用人工冷源制冷方式的选择,根据建筑物用途、所需制冷及冷水温度以及电源、水源和热源等情况,通过技术经济比较确定,并应符合下列要求:一、民用建筑应采用氟利昂压缩式或溴化锂吸收式制冷。

二、生产厂房及辅助建筑物,宜采用氟利昂或氨压约定缩式制冷。

注:采用溴化锂吸收式和蒸汽喷式制冷时,尚应分别符合本规范第6.3.3和6.3.4条的规定。

第6.1.2条选择制冷机时,台数不宜过多,一般不考虑备用,并应与空气调节负荷变化情况及运行调节要求相适应。

注:工艺有特殊要求必须连续运行的系统,可设置备用的制冷机。

第6.1.3条制冷量这580~1750KW(50*10~150*104kcal/h) 的制冷机房,当选用活塞式或螺杆式制冷机时,其台数不宜少于两台。

第6.1.4条大型制冷机房,当选用制冷量大于或等于1160KW(100*104kcal/h) 的一台或多台离凡式制冷机时,宜同时设置一台或两台制冷量较小的离心式,活塞式或螺杆式等压缩式制冷机。

第6.1.5条技术经济比较合理时,制冷机可按热泵特环工况应用。

第6.1.6条制冷装置和冷水系统的冷量损失,应根据计算确定。

概略计算时,可按下列数值选用:氟利昂直接蒸发式系统 5%~10% 间接式系统 10%~15%。

第6.1.7条冷却水的水温和水质,应符合下列要求:一、制冷装置的冷却水进口温度,不宜高于表6.1.7所规定的数值;二、冷却水的水质,应符合国家现行《工业循环冷却水处理设计规范》及有关产品对水质的要求。

冷却水进口温度表6.1.7注:当制冷剂为氟利昂时,冷凝器冷却水的进口温度,可适当提高。

第6.1.8条非全天使用权但在整个夏季可能经常使用的大型公共建筑,技术经济比较合理时,其空气调节的冷水系统,可设置蓄冷水池。

蓄冷水池的蓄冷量,应根据建筑物的使用权要求和预冷时间,通过计算确定。

第6.1.9条必要时,开式冷水系统应设置蓄水箱。

蓄水箱的蓄水量,应按系统循环量的10%~25%确定。

采暖通风与空气调节设计规范标准(GBJ19)

采暖通风与空气调节设计规范标准(GBJ19)

中华人民共和国国家标中华人民共和国国家标准采暖通风与空气调节设计规范GBJ19—87中华人民共和国国家标准采暖通风与空气调节设计规范GBJ19—87主编部门:中国有色金属工业总公司批准部门:中华人民共和国国家计划委员会实行日期:1988年8月1日关于发布《采暖通风与空气调节设计规范》的通知计标〔1987〕2480号根据原国家建委(81)建发设字第546号文的通知,由中国有色金属工业总公司,会同有关部门共同修订《工业企业采暖通风和空气调节设计规范》TJ19—75,已经有关部门会审。

现批准修订后的《采暖通风与空气调节设计规范》GBJ19—87为国家标准,自1988年8月1日起施行,原《工业企业采暖通风和空气调节设计规范》TJ19—75同时废止。

国家计划委员会1987年12月30日修订说明本规范是根据原国家建委(81)建发设字第546号文的通知要求,由中国有色金属工业总公司负责主编,具体由北京有色冶金设计研究总院,会同国内有关设计、科研和高等院校等17个单位,对原《工业企业采暖通风和空气调节设计规范》TJ19—75(试行)进行修订而成的。

在修订过程中,修订组进行了比较广泛深入的调查研究,总结了国内实践经验,吸取了近年来有关的科研成果,查阅了国内外大量资料,借鉴了国外同类技术中符合我国实际的内容,多次征求了全国各有关单位以及香港地区的意见,对其中一些重要问题进行了专题研究和反复讨论,最后召开了全国审查会议,会同各有关部门共同审查定稿。

本规范共分八章和十三个附录,主要内容有:总则、室内外计算参数、采暖、通风、空气调节、制冷、自动控制和消声与隔振等。

在执行本规范过程中,请各单位注意总结经验,积累资料,如发现需要修改和补充之处,请将意见和有关资料寄北京有色冶金设计研究总院暖通规范管理组(北京复兴路12号),以便今后修订时参考。

中国有色金属工业总公司1987年12月主要符号A——声级;矩形送风口边长a——围护结构温差修正系数;紊流系数B——距离;矩形送风口边长b——指数;系数C——静风;有效热压差与有效风压差之比;系数c f——风压系数C L——逐时冷负荷c p——空气的定压比热容c r——热压系数D——围护结构热惰性指标;直径d g——工作地点的宽度d——含湿量d o——送风口的直径d s——送至工作地点的气流宽度E——东;东风F,f——面积F o——送风口的有效截面积F j——进风口面积F p——排风口面积G——通风量G j——进风量G p——排风量g——重力加速度H——高度;水平h——高度;计算门窗的中心线标高;高差h j——进风口中心与中和界的高差h p——排风口中心与中和界的高差h z——中和界标高I——焓J——太阳总辐射照度J p——太阳总辐射照度的日平均值K——传热系数;安全系数L——风量;空气量l——门窗缝隙计算长度m——散热量有效系数;渗透冷空气量的综合修正系数m1,m2,m3——系数N——北;北风n——建筑物的楼层数;渗透冷空气量的朝向修正系数P——电动机功率P n——电动机轴功率△P——系统总压力损失△P min——调节阀全开时的压力损失Q——散热量;显热量;耗热量Q f——辐射散热量R o——围护结构传热阻R o·min——围护结构的最小传热阻R j——围护结构本体的热阻R n——围护结构内表面换热阻R w——围护结构外表面换热阻S——压力损失比;南;南风;距离s——净距t o——送风口的出口温度t d——屋顶下的温度t g——工作地点温度t1——露点温度t1p——累年最冷月平均温度t1s——邻室计算平均温度t max——累年极端最高温度t n,t n′——分别为室内计算温度和竖井计算温度t np——室内平均温度t p——排风温度t p·min——累年最低日平均温度t rp——累年最热月平均温度t sh——夏季空气调节室外计算逐时温度t s·max——与累年极端最高温度和最热月平均相对湿度相对应的湿球温度t s·rp——与累年最热月平均温度和平均相对湿度相对应的湿球温度t w——围护结构室外计算温度t wf——夏季通风室外计算温度t wg——夏季空气调节室外计算干球温度t wk——冬季空气调节室外计算温度t wl——逐时冷负荷计算温度t wn——采暖室外计算温度t wp——夏季空气调节室外计算日平均温度t ws季空气调节室外计算湿球温度t zp季空气调节室外计算日平均综合温度t zs季空气调节室外计算逐时综合温度△t H温度梯度△t1s计算平均温度与室外计算日平均温度之差△t r夏季室外计算平均日较差△t y室内计算温度与围护结构内表面温度的允许温差v o冬季室外平均风速;送风口的出口风速Vg——工作地点平均风速W——西;西风Z——距离α——系数αn—围护结构内表面换热系数αw—围护结构外表面换热系数β——夏季室外温度逐时变化系数ξj—进风口的局部阻力系数ξr—排风口的局部阻力系数ρ——围护结构外表面对于太阳辐射热的吸收系数ρnp——室内空气的平均密度ρp——排风温度下的空气密度ρw i通风室外计算温度下的空气密度ρwn采暖室外计算温度下的空气密度目录第一章总则第二章室内外计算参数第一节室内空气计算参数第二节室外空气计算参数第三节夏季太阳辐射照度第三章采暖第一节一般规定第二节热负荷第三节散热器采暖第四节辐射采暖第五节热风采暖与热风幕第六节采暖管道第七节蒸汽喷射器第四章通风第一节一般规定第二节自然通风第三节隔热降温第四节机械通风第五节除尘与净化第六节防火与防爆第七节设备、风管及其他第五章空气调节第一节一般规定第二节负荷计算第三节系统设计第四节气流组织第五节空气处理第六章制冷第一节一般规定第二节压缩式制冷第三节热力制冷第四节机房设计、设备布置及其他第七章自动控制第一节一般规定第二节检测、联锁与信号显示第三节自动调节与控制第四节制冷装置的自动保护与控制第八章消声与隔振第一节一般规定第二节消声与隔声第三节隔振附录一名词解释附录二室外气象参数附录三室外计算温度的简化统计方法附录四夏季太阳总辐射照度附录五夏季透过标准窗玻璃的太阳辐射照度附录六夏季空气调节大气透明度分布图附录七加热由门窗缝隙渗入室内的冷空气的耗热量附录八渗透冷空气量的朝向修正系数n值附录九自然通风的计算附录十系统式局部送风的计算附录十一除尘风管的最小风速附录十二法定计量单位与习用非法定计量单位换算表附录十三本规范用词说明附加说明第一章总则第1·0·1条为了在采暖、通风和空气调节设计中,体现艰苦奋斗、勤俭建国精神,贯彻国家现行的有关方针政策,以便为安全生产、改善生活和劳动条件、节约能源、保护环境、保证产品质量和提高劳动生产率提供必要的条件,特制订本规范。

建筑节能技术采暖、通风与空气调节节能技术

建筑节能技术采暖、通风与空气调节节能技术
低温度供水为低品位能源的使用创造了条件
良好的蓄热能力降低系统能耗
3 2
3 2
1
4
5 6
7
8
模式Ⅰ 房间温度控制器(有线)+ 电热(热敏)执行机构+带内置阀芯 的分水器
模式Ⅱ “房间温度控制器(有线)+分配器+ 电热(热敏)执行机构+带内置阀芯 的分水器”
4 3 2
1
5
6 7
8
9
2 4
1
3
模式Ⅲ:“带无线发射器的房间温度控制器+ 无线电接收器+电热(热敏) 执行机构+带内置阀芯的分水器”
适的比例 ➢ 维持炉膛负压等于设定值或在规定值范围内
汽压
燃料调节器
燃料量
过剩空气 系数
送风调节器
送风量
炉膛 负压
引风调节器
燃烧自动控制系统的组合示意图
引风量
蒸汽压力 变送器
控制器
炉膛负压 变送器
阻尼器
调速器
风速电动机
炉排 给煤量
比例给定器
执行机构
档板 送风量
控制器
执行机构
档板 引风量
燃烧自动控制系统框图
分户计量实现的途径 ➢安装热计量装置 ➢安装室温调控装置
分户热量表法 分户热水表法 分配表法 温度法
温度传感器
采集器 单元显示器
供水管
热力入口
T
积分仪
小区建筑
回水管
T 热量分配器
温度法
分室温控的目的 对室温进行调节,充分发挥行为节能的作用
分室温控的方式 在散热器支管上安装温控阀,通过控制进入
散热器的水流量来维持室内设定温度 温控阀的分类

暖通空调系统的自动化控制技术分析

暖通空调系统的自动化控制技术分析

暖通空调系统的自动化控制技术分析摘要:随着我国经济的快速发展,建筑业也得到了迅速地提高,暖通空调行业在社会发展中发挥着重要作用。

但是由于当前阶段能源资源短缺、环境污染等因素的影响,导致其节能减排工作无法顺利进行。

因此本文就将分析在自动化供热系统中存在的问题及优化措施,来有效促进节约能耗和环保型建筑事业更好更快发展,并提供相关启示与建议,从而实现暖通空调行业可持续健康稳定发展的目标,并为其他领域做出贡献。

关键词:节能减排;暖通空调;自动化控制引言暖通空调系统是电气设备的一种类型,将自动控制技术应用于暖通空调系统的运行中,可以更好地发挥暖通空调系统的实用功能。

暖通空调系统自动控制技术包括继电器自动控制技术、PLC自动控制技术和DDC自动控制技术。

各种自动控制技术都独具特色。

在暖通空调系统自动控制的应用中,不同的自动控制方式应结合室内温湿度控制目标的实际情况。

研究暖通空调系统自动控制的人员,还要从控制方式和原理的角度,积极有效地提高暖通空调系统的性能,以满足人们更高的使用需求。

1.暖通空调制冷系统的工作原理暖通空调的制冷系统主要是由压缩机、冷凝器、膨胀阀以及蒸发器四个部分构成,在这些部件中,压缩机是核心部件,它是将低温低压的制冷剂压缩为高温高压的气态制冷剂,通过蒸发器将高温高压的气态制冷剂变为低温低压的液态制冷剂,最后经过冷凝器时就会变成低温低压的气态制冷剂,而在制冷系统中最重要的一个部件就是膨胀阀,它主要负责控制制冷系统中冷冻水的流量,一旦膨胀阀出现问题则会导致温度没有达到设定值或者是出现温度过高现象,最后就会影响制冷系统工作运行的稳定性,这也是影响暖通空调制冷系统自动化控制技术发展的重要因素。

图1(中央空调系统组成)图2(暖通空调系统集控界面)2.暖通空调控制技术存在的问题目前我国的暖通空调系统的控制技术还存在许多问题,如一些企业在对暖通空调系统进行设计时,没有考虑到系统的实际运行状况,也没有考虑到如何对空调设备进行有效管理等问题,使得暖通空调在运行过程中出现了不能满足人们需要的情况;另外在对空调设备进行设计时,也没有考虑到使用寿命和可持续发展等因素。

采暖通风空气调节系统自动控制

采暖通风空气调节系统自动控制
21 .. 3常规仪表选择要求 () 1 四管制热水阀或冷水 阀应按照最大空调
的C , O 浓度变送器 ,测量精度不低于 2 %。
冷热水流量分别计算流量 系数 确 定冷水和 热水
阀 门 口径 .热 水 阀 应 选 等 百 分 比流 量 特 性 阀 。
2 风机盘管机组(C ) . 2 F U
送 器应该 安 装在 室 内 宜选 用输 出为直流 4~
1m / 《 。 h(采暖通风 与空气调节设计规范》G J 8 B-
1 9 规定每 人最少新风量为1 m / 7 9 。h 但正准备修 7
改 为 2 -3m。h 0 0 / 此 时 , 内室 外 C 。 均 浓 度 室 O平
( 3+ . s1 。 式 中 f 0 0 0o )C oL t 为测量温度: 要求精密
测量时 , 可使用I 71A级精度Pl。 E 5 C t 铂电阻 ( ̄ 0 0 c
()空 气 过 滤 器 堵 塞 报 警 。 3

j 场络 ( ) I 2 ; 网层仪 . 现 表
审] 1
4块 / 山 0 模
() 4 防冻开 关报警和连 锁控 制:低于设定 值
出压


5  ̄ , C时 防冻开 关动作 . 止风 机 , 闭新风 阀 . 停 关
种 连 续调节式根据蒸汽流量计算流量系数 确
定阀 门口径 蒸汽 阀应选 线性流量特性 阀。
( )封 闭式 空 调 水 系 统 中 阀 门 执行 器 关 断 4
压 力以空调水泵净扬程作为设计依据
( )送 风 温 度 检 测 宜 采 用风 管 式 热 电阻 温 5
度 传 感 器 应 使 感 温 元 件 位 于 送风 管 道 中 心 位 置 热 电阻 宜 采 用 I 7 1 E 5 B级 精 度 P 1 0 C t0 0 铂 电阻 ( 。 0C时 1 0 ,二 线 制 ) 允 许 偏 差 0Q 0

工业建筑供暖通风与空气调节通用规范

工业建筑供暖通风与空气调节通用规范

工业建筑供暖通风与空气调节通用规范征求意见稿23-11-11目次1总则 (1)2 基本规定 (2)3 建筑热工与室内设计参数 (6)3.1围护结构热工 (6)3.2室内设计参数 (6)4 供暖 (7)4.1一般规定 (7)4.2散热器供暖 (7)4.3热水辐射供暖 (8)4.4燃气红外线辐射供暖 (8)4.5热风供暖 (8)4.6电热供暖 (8)5 空气调节 (10)5.1一般规定 (10)5.2空气调节系统 (10)6 冷热源 (11)6.1一般规定 (11)6.2冷源 (11)6.3热源 (12)7 通风 (13)7.1一般规定 (13)7.2机械通风 (13)7.3事故通风 (14)8 除尘与有害气体净化 (15)8.1一般规定 (15)8.2除尘 (15)8.3有害气体净化 (16)1 总则1.0.1 为保障生产和生命财产安全、生态环境安全,提高能源资源利用效率,保证工业建筑供暖通风与空气调节工程建设质量和系统正常运行,满足经济社会高质量发展需求,依据国家有关法律、法规,制定本规范。

1.0.2新建、扩建和改建工业建筑供暖通风与空气调节工程的设计、施工、验收、运行维护及拆除必须执行本规范。

1.0.3 工业建筑供暖通风与空气调节工程应以保证人身和生产安全为前提,并应遵循下列原则:1保证生产和人员所必需的建筑室内环境;2符合国家节能、环保、防灾减灾和应急管理政策;3鼓励采用现代信息技术,提高运行维护水平;4 保证工程质量,鼓励技术创新。

1.0.4工程建设所采用的技术方法和措施是否符合本规范要求,由相关责任主体判定。

其中,创新性技术方法和措施,应进行论证并符合本规范中有关性能的要求。

2 基本规定2.0.1工业建筑室内环境应满足安全生产、职业健康要求。

2.0.2散发有毒有害气体、粉尘或纤维等污染物的生产应进行综合治理,并应采取有效的通风、净化措施,废气排放应符合环境保护要求。

2.0.3供暖通风与空气调节系统应节约能源,降低碳排放。

采暖通风与空气调节

采暖通风与空气调节

采暖通风与空气调节
一、采暖通风与空气调节的含义
采暖:又称供暖,指向建筑物提供热量,保持室内一定温度
通风:用自然或机械的方法向空间送入和排除空气的过程
空气调节:简称空调,是为满足生产、生活要求,改善劳动卫生条件,用人工的方法使某一房间或密闭空间内的空气温度、湿度、洁净度和空气流速等参数达到一定要
求的技术。

采暖、通风、空气调节习惯上简称为“暖通空调”
一、空调系统的组成
主要由空气处理设备、空气输送管道、空气分配装置以及运动自动控制装置组成。

暖通工程建设标准强制性条文

暖通工程建设标准强制性条文

<<暖通工程建设标准强制性条文>>3.1 一般规定《采暖通风与空气调节设计规范》GBJ 19--872.1.1设计集中采暖时,冬季室内计算温度,民用建筑的主要房间,宜采用16~20℃。

2.1.3冬季空气调节室内计算参数,应符合下列规定:一、舒适性空气调节室内计算参数:温度应采用18~22℃相对湿度应采用40%~60%风速不应大于0.2m/s2.1.6夏季空气调节室内计算参数,应符合下列规定:一、舒适性空气调节室内计算参数:温度应采用24~28℃相对湿度应采用40%~65%风速不应大于0.3m/s《住宅设计规范》GB 50096-19996.2.2设置集中采暖系统的普通住宅的室内采暖计算温度,不应低于表6.2.2的规定。

室内采暖计算温度表表6.2.2----------------------------------------------------------用房温度(℃)----------------------------------------------------------卧室、起居室(厅)和卫生间18----------------------------------------------------------厨房15----------------------------------------------------------设采暖的楼梯间和走廊14----------------------------------------------------------3.2 采暖《采暖通风与空气调节设计规范》GBJ 19-873.4.10采用煤气红外线辐射采暖时,必须采取相应的防火、防爆和通风换气等安全措施。

3.6.3当供汽压力高于室内采暖系统的工作压力时,应在采暖系统入口的供汽管上装设减压装置。

3.6.24穿过建筑物基础、变形缝的采暖管道,以及镶嵌在建筑结构里的立管,应采取预防由于建筑物下沉而损坏管道的措施。

供暖通风与空气调节

供暖通风与空气调节
Q W
式中Q单位为kJ/h, W单位为kg/h。
(1-11)
例:已知B=101325Pa,湿空气初始参数ta=20℃、 φ=60%,当加入10000kJ/h的热量和加入2kg/h 的湿量后,温度tb=28℃。求湿空气的终状态。
解:方法1:求热湿比,在i—d图上,通过A点做此 热湿比值的平行线,与tb=28℃等温线交点 即为湿空气的终状态。 方法2:在i—d图上通过热湿之间的比例关系, 用作辅助点的方法作出热湿比线。
2.等相对湿度线: 由式(1-5)可得:
Bd pq 0.622 d
因此给定不同的d值即可求出对应的Pq值,在i—d 图上,取一横坐标表示水蒸气分压力值。见图。
在已建立起水蒸气压力坐标的条件下,对应于不 同温度下的饱和水蒸气压力可从热工手册中查到,连 接不同等温线和其对应的饱和水蒸气线的交点即可得 % 到 100 的等 线,又据 Pq / Pq.b 或 Pq Pq.b , 当 const 时则可求出不同温度下的Pq值,连接各等 温线与Pq值相交的各点即成等 线。 这样作出的i—d图包含了B、t、d、i、φ、Pq等湿 空气的参数。 在B值一定的条件下,在t、d、i、φ中已知任意 两个参数,则湿空气的状态就确定了,在i—d图上也 就是有了一个确定的点,其余参数均可查出。因此, 将这些参数称为独立参数。但d与 Pq则不能确定一个 空气状态点,因此d与 Pq只能有一个作为独立参数。
作业:已知B=101325Pa,湿空气初始参数ta=30℃、 φ=40%,当减少10000kJ/h的热量和加入2kg/h 的湿量后,温度tb=20℃。求湿空气的终状态。
第三节 湿球温度与露点温度
湿球温度的概念在空气调节中至关重要。 在理论上,湿球温度是在定压绝热条件下,空气 与水达到稳定热湿平衡时的绝热饱和温度,也称热力 学湿球温度。 下面用图分析以下其 热力过程: 由于小室绝热,其稳 定流动能量方程为:

酒店采暖通风与空气调节初步设计说明及技术措施

酒店采暖通风与空气调节初步设计说明及技术措施

采暖通风与空气调节初步设计说明及技术措施:1.工程概况该项目酒店主体总面积:45035.79m2,客房总计236间/套,酒店南水面客房总面积(6套);酒店总面积:47015.79m2,总建筑高度为46.9米,属一类高层公共建筑。

(这其中的面积不准确,以最终的施工图为准)2.设计依据:《旅馆建筑设计规范GJ62—90》《商店建筑设计规范GJ48—88》《饮食建筑设计规范GJ64—89》《体育建筑设计规范J GJ31—2003》《民用建筑供暖通风与空气调节设计规范》(GB 50736—2012)《高层民用建筑设计防火规范GB50045—95》(2005年版)《大气污染物综合排放标准》(GB16297-1996)《室内空气质量标准GB/T18883-2002》《城市区域噪声标准GB3096-93》《民用建筑隔声设计标准》GBJ118-88》《旅游旅馆建筑热工与空气调节节能设计标准GB50189-93》《公共建筑节能设计标准DBJ 14-036-2006》青岛市民用建筑节能条例3.设计范围3.1本工程初步设计包括以下内容:1. 冷热源2. 空调、采暖、通风3. 防排烟及通风系统4. 热能动力5. 自动控制要求3.2 需与有关单位协作设计的内容:1. 空调采暖通风的自动控制系统需与自控设备制造厂家配合,结合电气专业图纸,由专业公司另行设计,本设计只提出自控要求。

2. 厨房内通风系统需与厨房设备制造厂家配合,由专业公司另行设计,本设计只预留条件。

补风采用的空调新风机组已设计,但必须由厨房设计专业公司确认后方可施工。

3. 燃气系统由甲方委托专业的燃气设计公司设计。

4. 柴油发电机工作时的排风及送风由柴油发电机专业厂家设计施工,柴油发电机工作时的排烟要进过处理,必须达到排放标准方可排放。

本设计只预留排风及进风井道,并作柴油发电机房平时的排风。

4.设计参数及设计标准4.1 室外设计参数(参考地区:南京)4.2 室内设计参数(按五星级酒店标准)注:中餐厨房换气次数为60次/h;西餐厨房换气次数为50次/h。

采暖通风与空气调节设计规范(GB 50019—2003)

采暖通风与空气调节设计规范(GB 50019—2003)

采暖通风与空气调节设计规范GB 50019—2003中华人民共和国建设部/中华人民共和国国家质量监督检验检疫总局2003-11-05批准2004-04-01实施前言根据建设部建标[1998]第244号文件“关于印发《一九九八年工程建设国家标准制定、修订计划》的通知”要求,由中国有色工程设计研究总院主编,会同国内有关设计、科研和高等院校等单位组成修订组,对GBJ 19—87《采暖通风与空气调节设计规范》进行了全面修订。

在修订过程中,修订组进行了广泛深入地调查研究,总结了国内实践经验,吸取了近年来有关的科研成果,借鉴了国外同类技术中符合我国实际的内容,多次征求了全国各有关单位以及业内专家的意见,对其中一些重要问题进行了专题研究和反复讨论,最后召开了全国审查会议,会同各有关部门共同审查定稿。

本规范共分9章和9个附录,主要内容有:总则、术语、室内外计算参数、采暖、通风、空气调节、空气调节冷热源、监测与控制、消声与隔震等。

本规范修订的主要内容有:一、新增室内热舒适性、室内空气质量的要求以及对室内新风作了规定;二、新增有关采暖地区划分的规定;三、新增热水集中采暖分户热计量的规定;四、新增有害和极毒、剧毒生产厂房布置的安全要求条文;五、新增事故通风一节;六、取消防火防爆一节,其内容分别纳入通风的其他有关条文;七、新增对于没置集中空气调节的建筑物及民用建筑利用自然通风的要求;八、对空气调节内容进行全面修订,新增变风量空气调节系统、低温通风系统、变制冷剂流量分体式空气调节系统、热回收系统等内容以及对空气调节水系统的设计要求;九、对空气调节的冷热源进行全面修订,新增热泵、蓄冷、蓄热、换热装置的设计规定;对空气调节冷却水设计要求新增加了规定;十、新增关于直燃型溴化锂吸收式冷(温)水机组的设计要求;十一、“自动控制”改为“监测与控制”,修订并新增对采暖、通风、空气调节系统和防排烟的监测与控制的要求;十二、新增对振动控制设计的规定,以及对室外设备噪声的控制要求;十三、取消“室外气象参数”表,另行出版《采暖通风与空气调节气象资料集》。

暖通空调系统的自动化控制技术

暖通空调系统的自动化控制技术

暖通空调系统的自动化控制技术摘要:近年来我国整体发展良好,社会各行业发展中所用技术与理念得到一定完善、优化与创新。

在现代建筑工程之中,暖通空调正常运转需要耗费大量能源,能源逐渐稀缺的趋势下,节能技术研究更加受到重视。

现代城市建筑的暖通空调需要消耗50%左右的能源,这就需要建筑行业在设计暖通空调时灵活运用节能技术,从而在真正意义上促使建筑工程中的暖通空调达成节能环保目标。

基于此,本篇文章对暖通空调系统的自动化控制技术进行研究,以供相关人士参考。

关键词:暖通空调、自动化控制、技术引言暖通空调系统是一种电气设备类型,在暖通空调系统运行中应用自动控制技术,能够更好地发挥暖通空调系统的实用功能。

暖通空调系统的自动控制技术包括了继电器自动控制技术、PLC自动控制技术和DDC自动控制技术,各种自动控制技术都具有独特性,在暖通空调系统的自动控制应用中,应当结合实际情况,在室内温度和湿度等控制目标中,综合利用不同的自动控制方式。

暖通空调系统自动控制的研究人员,也要从控制方式和原理的角度,积极有效地提高暖通空调系统性能,以满足人们更高的使用需求。

一、暖通空调技术在建筑中的运用原则1.1回收原则在建筑工程暖通空调内部之中,有很多零件或部件自身都具备或可起到重要作用,因此,对这种自身作用较大的零件或部件,一定要有针对性地回收,并于回收之后,可以通过重新加工与调整实现循环利用的目的。

在实际回收暖通空调中重要零件与部件时,一定要明确区分回收和回用之间的差别,所以这种回收原则并非是没有任何基础与底线,十分随意且规模较大地回收暖通空调中重要零件与部件,在落实回收原则时需要根据零件类型进行合理回收。

1.2循环原则循环原则是以回收原则作为基础的,主要是指在通过回收原则将暖通空调中重要部件与零件回收以后,针对回收零件展开进一步处理,这样便可大幅增加能源在暖通空调中的利用率。

简单来讲就是针对暖通空调中没有应用或已经报废的重要零件,展开进一步加工处理,促使没有应用或已经报废的重要零件可在建筑工程暖通空调之中循环应用,循环原则可以有效减少回收原则落实时所耗成本,同时增加暖通空调的经济效益与社会效益。

自动控制设计规范采暖通风与空气调节

自动控制设计规范采暖通风与空气调节

自动控制设计规范(采暖、通风和空气调节系统)一般规定第7.1.1条采暖、通风和空气调节系统的自动控制,包括参数检测、参数与动力设备状态显示、自动调节与控制、工况自动转换、设备联锁与自动保护以及中央监控与管理等。

设计时,应根据建筑物的用途、系统和设备运行时间,经技术经济比较确定其具体内容。

第7.1.2条符全下列条件之一时,采暖、通风和空气调节系统,应采用自动控制:一、采用自动控制可合理利用能量实现节能时;二、采用自动控制,方能防止事故,保证系统和设备运行安全可靠时;三、工艺可使用条件对室内温湿度波动范围有一定要求时。

第7.1.3条在满足控制功能和指标的条件下,应尽量简化自动控制系统的控制环节。

第7.1.4条采用自动控制的采暖、通风和空气调节系统,应做到系统和管道设计合理,防止运行调节时各并联环路压力失调,其调节机构特性应符合要求。

第7.1.5条自动控制方式的选择,应根据使用条件及要求,采用电动式、气动式电动气混合式。

第7.1.6条设置自动控制的采暖、通风和空气调节系统,应具有手动控制的可能。

第7.1.7条采用自动控制时,宜设控制室,当系统控制环节及仪表较少时,其控制台屏可直接布置在机房内。

第7.1.8条高层民用建筑和生产厂房的空气调节系统,当其数量较多时,可设中央和区域两级控制。

检测、联锁与信号显示第7.2.1条采暖、通风和空气调节系统有代表性的参数,应在便于观察的地点设置检测仪表,当采用集中控制时,其主要参数应设置遥测仪表。

第7.2.2条对下列部分或全部参数的测量,应根据具体情况设置必要的检测仪表:一、采暖系统的供水,供汽和回水干管中的热媒温度和压力;二、热风采暖系统的室内温度,送风温度和热媒参数;三、送风系统的送风温度和热媒参数;四、兼作热风采暖的送风系统的室内温度、送风温度和热媒参数;五、除尘系统的除尘器进出口静压差;六、空气调节系统的下列参数:(1)室内外温湿度;(2)一、二次混合风温度;(3)喷水室或表面冷却器出口空气温度;(4)加热器出口空气温度;(5)送回风温度;(6)加热器进出口热媒温度和压力;(7)喷水室或表面冷却器用的水泵出温度和压力;(8)喷水室颧表面冷却器进出口的冷水温度;(9)空气过滤器进出口的静压差;第4.3.1条空气调节系统的调节方式,应根据调节对象的特性数、房间热湿负荷变化的特点以及控制参数的精度要求等进行选择。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

1 8 m 3 / h (《采暖通风与空气调节设计规范》G B J -
1 9 9 7 规定每人最少新风量为 1 7 m3/h ,但正准备修
改为 2 0 ~3 0 m 3 / h ,此时,室内室外 CO 2 平均浓度 差允许值为 7 0 0 × 10-6 )。
表 3 CO2 平均浓度差允许值与最小新风量[2]
表 4 国家标准《风机盘管机组》[1]JB/T4283-91
水压降(k P a ) 型号 风量 供冷量 供热量 (括号中为产 水流量
(m3/h)(W) (W) 品实测数据) (L/s) 2.5 250 1400 2100 15(3.5) 0.07 3.5 350 2000 3000 20(5.0) 0.10 5 500 2800 4200 24(7.2) 0.15 6.3 630 3500 5250 30(10.7) 0.18 7.1 710 4000 6000 40(20.0) 0.20 8 800 4500 6750 44(17.2) 0.22 10 1000 5300 7950 54(28.3) 0.25 12.5 1250 6600 9900 34(8.14) 0.33 14 1400 7400 11100 38(24.0) 0.37 16 1600 8500 12750 40(13.2) 0.40 20 2000 10600 15900 50(17.6) 0.50
系数,确定阀门口径,选用等百分比流量特性阀。
(3 )蒸汽加湿阀有开关式和连续调节式两
种,连续调节式根据蒸汽流量计算流量系数,确
定阀门口径,蒸汽阀应选线性流量特性阀。
(4 )封闭式空调水系统中,阀门执行器关断
压力以空调水泵净扬程作为设计依据。
(5 )送风温度检测宜采用风管式热电阻温
度传感器,应使感温元件位于送风管道中心
4 4 76 13500 280 191 74.3 9.1 23 250 243 94.6 11.6 47
5 5.5 76 17000 350 225 89.9 10.7 29 300 294 114 14 63
6 7.5 76 20000 430 293 114 14.0 35 400 336 143 17.4 73
(7 )送风湿度检测宜采用风管式、输出为直 流 4 ~2 0 m A 或 0 ~1 0 V 的电容湿度变送器,测量 精度在相对湿度 R H 3 0 % ~7 0 % 时应为 3 % 。
(8 )当新风机用作直流式空调机时,湿度变 送器应该安装在室内,宜选用输出为直流 4 ~ 2 0 m A 或 0 ~1 0 V 的电容湿度变送器,测量精度在 相对湿度 R H 3 0 % ~7 0 % 时应为 3 % 。
7 11 76 25000 490 345 138 16.4 50 450 442 172 21 102
全新风进风干球/湿球温度:34℃/28℃ 冷冻水进出水温:12℃/7℃
2.1.2 控制内容
(1 )新风阀连锁控制:风机启动,新风阀全
开;风机停止,新风阀关闭。
(2 )风机起停控制:时间程序或手动控制。
阀连锁,两管制冬夏均运行的风机盘管设手动控
制冬夏切换开关。通常,温度控制器与三速开关、 冬夏切换开关制作成为一个整体。
(2 )风机盘管机组微控制器是专用控制器,
39 Intelligent Building & City Information 2006 5 No. 114
本刊策划 Special Design
开关控制加湿阀或比例积分控制连续调节加湿阀
开度。
(7 )C O 2 浓度控制:新风量可根据室内室外空 气 C O 2 浓度差决定。在变风量直流式空调机新风系 统中,根据设在室内的 C O 2 浓度变送器输出可连续 调节变速新风风机速度,减少新风量输入以达到
节能目的。国家标准《商场(店)书店卫生标准》
量的新风。空调机有定风量空调机和变风量空调
机,有两管制空调机和四管制空调机。
2.3.1 主要参数
风量(m 3 / h )、水流量(L / s )、盘管水压降
(k P a)、水管接管直径(mm )、机外余压(Pa ),见
表 5。
表 5 空调风机组典型产品数据(York)
表冷段
水管
4 排盘管
6 排盘管
(3 )空气过滤器堵塞报警。
(4 )防冻开关报警和连锁控制:低于设定值
5 ℃时,防冻开关动作,停止风机,关闭新风阀,
热水阀全开,发出报警信号。
(5 )送风温度显示及设定值控制:根据送风
温 度 设 定 值( 直 流 式 空 调 机 为 室 内 温 度 设 定 值 ),
比例积分连续调节冷水阀或热水阀开度,见表 2 。
GB 9670-88 规定的 CO2 浓度为 1500 × 10-6,因此,
38
智能建筑与城市信息 2006年 第5 期 总第114期
室内 CO2 浓度可设定为 1 5 0 0 × 10-6(0 . 1 5 % ),城 市的室外 C O 2 浓度约为 3 0 0 × 10 -6~4 0 0 × 10 -6, 根据表 3 的数据,可以决定每人最少新风量为
表 1 新风机组典型产品数据(York-YSE)
表冷段
水管
4 排盘管
6 排盘管
风机 序号 功率
接直管径(风m3 /量h )机静外压
全热 显热 量量
水流 量
水压 降
机外 静压
全热 量
显热 量
水流 水压 量降
(k W )(m m ) (Pa)(k W ()k W )(L/s)(kPa)(Pa)(k W )(k W )(L/s)(kPa)
1 1.1 60 5000 120 80.1 31.2 3.8 35 100 96.4 37.6 4.6 50
2 2.2 60 8500 180 124 48.2 5.9 74 150 155 59.8 6.7 110
3 4 76 12000 270 173 67.2 8.2 20 250 218 84.9 10.4 39
(9 )当新风机用作直流式空调机时,C O 2 浓度 变送器应该安装在室内,宜选用 C O 2 浓度输入为 0~2000 × 10 -6、输出为直流 4 ~20mA 或 0 ~1 0 V 的 C O 2 浓度变送器,测量精度不低于 2 % 。
2.2 风机盘管机组(FCU) 风机盘管机组是可与新风机配套使用的空调
风机 序号 功率
接直管径(m风3 /量h )机静外压
全热 显热 量量
水流 量
水压 降
机外 静压
全热 量
显热 量
水流 量
水压 降
(k W ()m m ) (Pa)(k W )(k W )(L/s)(kPa)(Pa)(k W )(kW )(L/s)(kPa)
1 1.1 48 5000 120 34.1 23.5 1.6 12 100 43.9 28.1 2.1 11
5 5.5 60 17000 350 90.4 67.8 4.3 8 300 128 85.4 6.1 16
6 7.5 60 20000 430 121 87.1 5.8 11 400 163 106 7.8 20
7 11 60 25000 490 141 103 6.7 12 450 194 128 9.3 27
每人最小新风量(m3 / h )
18 27 36 54
室内室外 CO 2 平均浓度差允许值(10- 6 ) 1050 700 500 350
2.1.3 常规仪表选择要求
(1 )四管制热水阀或冷水阀应按照最大空调
冷热水流量分别计算流量系数,确定冷水和热水
阀门口径,热水阀应选等百分比流量特性阀。
(2 )两管制按照最大空调冷冻水流量计算流量
2 2.2 48 8500 180 51.5 36.6 2.5 18 150 69.2 44.9 3.3 23
3 4 60 12000 270 67.5 49.3 3.2 8 250 96.3 62.6 4.6 13
4 4 60 13500 280 77.6 56.6 3.7 8 250 107 69.4 5.1 13
式中 t 为测量温度。
(6 )当新风机用作直流式空调机时,温度传
感器应该安装在室内,选用墙挂式温度传感器。
宜采用热电阻温度传感器,热电阻宜采用 IEC751
B 级精度 Pt1000 铂电阻(0℃时 1000 Ω,二线制),
允许偏差(0.30+0.005 |t| )℃,式中 t 为测量温
度;要求精密测量时,可使用 I E C 7 5 1 A 级精度
可以提供四管制的热水阀、冷冻水阀连续调节控 制和风机三速控制,冬夏自动切换(两管制)微 控制器提供以太网或现场总线通信接口,构成现 场网络层,是开放式系统,中央工作站能够进行 集中监控,最大限度节约能耗。
2.3 空调机
空调机是集中空调系统,在运行中,使用一
部分回风,为了人员卫生条件,又必须采用一定
2 采暖通风及空气调节系统自动控制
2.1 新风机 新风机主要用于给风机盘管空调房间提供新
风,也可以作为直流式空调系统的空调机。有两 管制新风机和四管制新风机,有定风量新风机和 变新风量新风机。 2.1.1主要参数
风量(m3/h),水流量(L/s),盘管水压降(kPa),
水管接管直径(m m ),机外静压(P a ),见表 1 。
末端设备,包括空调水盘管系统和一台三速风机。 2.2.1 主要参数
(1)名义风量:标准状态(大气压 101.3kPa, 温度 2 0 ℃,密度 1 . 2 k g / m 3)时的风量(m 3/ h )。
(2)名义供冷量:规定工况下的总除热量(显 热及潜热),单位 W 或 k W 。
(3)名义供热量:规定工况下的总显热量,单 位 W 或 k W ,见表 4 。