新版_VISTA128简易操作手册.
霍尼韦尔VISTA-128BPT编程说明(详细对照)

Honeywell霍尼韦尔VISTA系列报警主机编程说明深圳市麦驰物联股份有限公司工程服务部-整理编辑目录一、设备认识 (3)Vista系列报警主机(以Vista 128BPT为例) (3)Vista系列报警主机控制键盘(6160) (7)4193SN/SNP单地址码两回路模块(已停产) (7)4293SN单防区扩充模块 (8)4101SN V-Plex单防区总线继电器模块 (9)4204ECP总线继电器模块 (9)4208SN V-Plex总线8防区扩充模块 (10)4297总线延伸器 (10)4232AP 32路继电器模组 (12)VPlex-VSI总线监测/隔离模块 (13)IP-2000 2.0网络接口模块 (14)二、主机编程 (17)防区编程: (17)删除防区: (21)子系统编程: (23)1.子系统数量划分: (23)2.子系统跳转功能设置: (23)3.防区子系统划分及布防延时更改 (24)继电器输出设备编程: (25)1.4101SN单防区继电器模块编程 (25)2.防区列表编程 (29)3.查看防区列表 (30)4.4232AP 32路继电器模块编程设置(VISTA 128BPT) (30)4100SN与IP2000模块编程: (31)三、键盘日常使用操作 (33)1.布撤防操作 (33)2.子系统跳转 (33)四、主机常见问题解析 (34)五、键盘常见显示中英文对照 (36)一、设备认识Vista系列报警主机(以Vista 128BPT为例)(图1)由原安定宝、C&K打底建立的Honeywell安防是全球最大的报警器材制造商,其制造的VISTA系列报警主机(图1)是业界最早、认可度最高的大型总线制报警主机,主要用来接收处理前端探测器发送回来的报警信号,是先进的多功能控制主机。
功能框图Vista - 128BPT常规接线方式Vista - 128BPT总线接线方式Vista - 128BPT无线接线方式Vista - 128BPT总线连接图表格(一):总线负载电流、线径与总线驱动距离的关系Vista系列报警主机控制键盘(6160)(图2)6160键盘(图2)用来给报警主机编程和防区布撤防相关操作4193SN/SNP单地址码两回路模块(已停产)4193SN用于总线扩充,可以扩展成2个回路:白色线与黄色线组成一个10K电阻监测的回路或者黄色线与黑色线组成常闭回路;这两个回路任选其一,都是第一个防区;绿、黑线组成常闭形式的第二个防区,在编程时要注意防区回路选择。
新版_VISTA128简易操作手册

输入4140 1 4140 1,主机将停止报警,将联接001防区的2K电阻重新接好,001防区试验完成。
(二)ห้องสมุดไป่ตู้置使用序号式总线(使用4193SN和4293SN)联接的防区
按*键盘显示:010 REPORT CODE
1 st 00 2nd 00 00
此项设定010防区通讯码,1 st 11向第一报警中心发送报警信息
2 nd11向第二报警中心发送报警信息
按***键盘显示:010INPUT TYPE
00
此项设定010防区的接入类型,06表示序号式总线(使用4193SN和4293SN)
A XXX-XXXX:1
L下方输入010防区占用此4193SN的回路的序号,4193SN有两个回路,黄—黑为第一回路,绿—黑为第二回路
从4193SN线接在一起的三根线中抽出黄线,VISTA 120会自动读出这个4193SN的地址码并显示在键盘上,这个地址码与4193SN上粘贴的数码一致。
按*93键盘显示:ZONE PROG
1=YES 0=NO
按1进入防区编程
键盘显示SET TO CONFIRM?
1=YES 0=NO
输入1,按*
键盘显示ENTER ZONE NO.
000=QUIT 001
输入010(以010防区为例)*
键盘显示010 ZT P RC IN:L
00 1———
目前显示的是010防区的信息
双向开关式总线(Dip SW Poll)使用4208U编号07;
(一)设置电路板上接线(Hardwire)防区,以001防区为例
霍尼韦尔VISTA120(128)主机防区快速编程

VISTA120/128/250/250BPT主机防区编程(快速编程部分)1, 4140 8000 进入编程,键盘显示:Program Mode*Fill # View -002, 输入*93,键盘显示:ZONE PROG . ?1=YES 0=NO3,输入“0”,键盘显示:EXPERT MODE ?1=YES 0=NO4,输入“1”,键盘显示:Set to confirm ?1=YES 0=NO5,输入“1”,键盘显示:ZN ZT P RC INL001 09 1 10 001ZN 代表防区号,ZT代表防区类型,P代表分区,INL代表输入类型此时光标会在防区号的第一位“0”上面闪烁6,输入防区号,比如从10防区开始编程,则输入“0 1 0”显示:ZN ZT P RC INL010 00 1 20 0017,此时光标在010 的第一位0上闪烁,输入“*”,光标移到ZT下面00上面,然后输入防区类型,常用的防区类型是即时防区(03)和24小时防区“07”,这里以即时防区为例,输入“03”,键盘显示:ZN ZT P RC INL010 03 1 10 0018,此时光标在“P”下面的1上闪烁,这里代表的是分区的意思,就是说10防区在第一分区里,如果主机划分过子系统,这里需要根据实际情况填写对应的分区号,这里暂时不提,就以一个分区为例,输入“*”“*”(两次*号),光标会移到最右边的001上并在第一位的0上闪烁,这里需要输入的是输入类型,一般是总线输入,总线输入为06,这里输入“0 6 ”(注意是两位数,不要理会001的三位数),输入完之后,键盘显示:ZN ZT P RC INL010 03 1 10 SL19,继续输入“*”“*”“*”(三次*号,120主机为两次),键盘显示:010 Input S/N : LA×××-××××:110,这里就需要输入地址码了,比如地址码为001 5801,直接输入数字即可,输入“0”“0”“1”“5”“8”“0”“1”,注意,输入地址码的时候不可操作过快,尽量输完一个数字,等这个数字显示出来以后再输入下个数字。
霍尼韦尔Vista-128BPT报警主机编程说明(常用版)-工程服务部编辑

Honeywell霍尼韦尔VISTA系列报警主机编程说明深圳市麦驰物联股份有限公司工程服务部-整理编辑目录一、设备认识 (3)Vista系列报警主机(以Vista 128BPT为例) (3)Vista系列报警主机控制键盘(6160) (7)4193SN/SNP单地址码两回路模块(已停产) (7)4293SN单防区扩充模块 (8)4101SN V-Plex单防区总线继电器模块 (9)4204ECP总线继电器模块 (9)4208SN V-Plex总线8防区扩充模块 (10)4297总线延伸器 (10)4232AP 32路继电器模组 (12)VPlex-VSI总线监测/隔离模块 (13)IP-2000 2.0网络接口模块 (14)二、主机编程 (17)防区编程: (17)删除防区: (21)子系统编程: (23)1.子系统数量划分: (23)2.子系统跳转功能设置: (23)3.防区子系统划分及布防延时更改 (24)继电器输出设备编程: (25)1.4101SN单防区继电器模块编程 (25)2.防区列表编程 (29)3.查看防区列表 (30)4.4232AP 32路继电器模块编程设置(VISTA 128BPT) (30)4100SN与IP2000模块编程: (31)三、键盘日常使用操作 (33)1.布撤防操作 (33)2.子系统跳转 (33)四、主机常见问题解析 (34)一、设备认识Vista系列报警主机(以Vista 128BPT为例)(图1)由原安定宝、C&K打底建立的Honeywell安防是全球最大的报警器材制造商,其制造的VISTA系列报警主机(图1)是业界最早、认可度最高的大型总线制报警主机,主要用来接收处理前端探测器发送回来的报警信号,是先进的多功能控制主机。
功能框图Vista - 128BPT常规接线方式Vista - 128BPT总线接线方式Vista - 128BPT无线接线方式Vista - 128BPT总线连接图表格(一):总线负载电流、线径与总线驱动距离的关系Vista系列报警主机控制键盘(6160)(图2)6160键盘(图2)用来给报警主机编程和防区布撤防相关操作4193SN/SNP单地址码两回路模块(已停产)4193SN用于总线扩充,可以扩展成2个回路:白色线与黄色线组成一个10K电阻监测的回路或者黄色线与黑色线组成常闭回路;这两个回路任选其一,都是第一个防区;绿、黑线组成常闭形式的第二个防区,在编程时要注意防区回路选择。
VISTA128报警主机常用编程

2. 退出数据编程模式 :可以用如下 A 或 B方法进入:
3. 数据项编程模式 :分为三页显示(*00—*90,1*01—1*77,2*00—2*24) 4. #93菜单编程模式:(是很重要的编程)进入数据编程模式后按#93进入。 5. 分子系统数据项编程模式:进入编程后
若想在输入完前回到全局编程,输入任意一个*+全局数据项即可。
输入1进入继电器编程状态
继电器默认的启动状态
继电器默认的停止状态
继电器的动作方式:
0=未使用; 1=闭合2秒; 2=持续闭合; 3=断续闭合;4= 交替闭合和断开
事件触发的类型:0=未使用;1=报警;2=失效;3=故障
可启动继电器的防区列表,共15个防区列表,如果不使用列表,
直接输入00
泽博内部培训资料
继电器编程--Output Prog
可启动继电器的防区号。
可启动继电器的防区类型。
泽博内部培训资料
继电器编程--Output Prog
可启动继电器动作的子系统。子系统与事件类型相关联
可停止继电器动作的防区列表。 可停止继电器动作的防区类型。类型表与启动类型表一致
可停止继电器动作的子系统。
继电器组别分类。可以时间窗来驱动继电器组动作 禁止用户手动控制的选项
泽博内部培训资料
Vista128BPT编程
防区编程(ZONE PROG)
泽博内部培训资料
Vista128BPT的防区编程
该选项适用 于1、2、4、10类型的防区,当防区触发 时,主机可以进行强制布防,在延进时间结束前,恢 复故障防区后,这个防区也可以正常报警。 当防区触发时,延进时间结束前,自动旁路故障防区
泽博内部培训资料
产用篇:Vista报警主机
新版_VISTA128简易操作手册

VISTAR—120简易编程操作手册防区编程一、设置6139编程键盘地址为01开机同时按1 3键5秒,键盘显示Addr=31或Addr=xx,输入01按*键盘绿灯亮,显示***DISARMED***READY TO ARM键盘地址为00时,完成编程后可能会出现键盘不能操作,6148键盘不能编程二、设置每个防区按防区接入类型区分共有6种:电路板上接线(Hardwire)001—009防区可以使用,编号01;受监控无线(RF Xmitter)编号03;不受监控无线(Unsupevsd) 编号04;无线按钮类型(Button RF)编号05;序号式总线(Serial Poll)使用4193SN和4293SN,编号06;双向开关式总线(Dip SW Poll)使用4208U 编号07;(一)设置电路板上接线(Hardwire)防区,以001防区为例先将随机配的2K电阻按接线图接在VISTA—120的端子上进入编程模式输入4140 8000 (4140为出厂设置的安装员密码)进入编程模式,键盘显示:Program Mode*Fill # View按*93 键盘显示ZONE PROG1=TES 0=NO按1进入防区编程键盘显示SET TO CONFIRM?1=YES 0=NO输入1,按*键盘显示ENTER ZONE NO.000=QUIT 001输入01(以001防区为例),按*键盘显示001 ZT P RC IN :L09 1 ———目前显示的是001防区的信息,按*键盘显示001ZONE RESPONSEFire 09目前001防区为火警防区,请根据具体情况输入防区类型的编号编号01-出入口防区1型,布防时有延时,进入时有延时,延时时间由*09和*10设定;编号02—出入口防区2型,布防时有延时,进入时有延时,延时时间由*11和*12设定;编号03-周边防区,布防时有效,撤防时无效;编号04—内部防区,留守布防时无效,外出布防时有效,撤防时无效;编号06—24小时无声防区;编号07-24小时有声防区;编号09—火警防区;编号00-无用防区.其他防区类型的编号请参照英文手册。
VISTA-128编程指南

VISTA-128编程指南VISTA-128报警操作步骤一.网络通讯模块IPM-VISTA SUPER II的编程: 进入编程: 操作密码4140+8000键盘显示:Program Mode*Fill# View-00进入报告编程:*93键盘显示ZONE PROG. ?1=YES 0=NO输入两次0键盘显示:REPORT CODE PROG1=YES 0=NO按一下1按一下0键盘显示:RSTR,SUPV.CODE?1=YES 0=NO按下1键盘显示:ENTER ZN FOR GRP000=Quit输入001点击*号键键盘显示:ALARM RESTOREGRP 001-016输入01点击*号键键盘显示:TROUBLEGRP 001-016输入01点击*号键键盘显示:TROUBLE RESTOREGRP 001-016输入01点击*号键键盘显示:BYPASSGRP 001-016输入01点击*号键键盘显示:BYPASS RESTOREGRP 001-016输入01点击*号键键盘显示:ENTER ZN FOR GRP000=Quit 017防区数以16为一组,重复以上操作直至到你所接的防区数为止;退出输入000按*号键键盘显示:QUIT REPORT MENU1=YES 0=NO输入0键盘显示:SYSTEM GROUP #1?1=YES 0=NO按下1键盘显示:CLOSE1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:OPEN1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:LOW BATTERY1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:LOW BATTERY RSTR1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:AC LOSS1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:AC RESTORE1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:PERIODIC TEST1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:POWER1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:CANCEL1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:PROGRAM TAMPER 1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:QUIT REPORT MENU 1=YES 0=NO输入0键盘显示:SYSTEM GROUP #2?1=YES 0=NO输入1键盘显示:STAY1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:TIME SET,LOG RST 1st 01 2nd 00输入01再按下*号键1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:EXIT ERROR ZONE 1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:RESENT CLOSE1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:QUIT REPORT MENU 1=YES 0=NO输入0键盘显示:SYSTEM GROUP #3?1=YES 0=NO输入1键盘显示:EARLY OPEN1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:EARLY CLOSE1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:LATE OPEN1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:LATE CLOSE1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:FAILED TO OPEN1st 01 2nd 00输入01再按下*号键1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:AUTO ARM FAILED 1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:SCHEDULE CHANGE 1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:QUIT REPORT MENU 1=YES 0=NO输入0键盘显示:SYSTEM GROUP #4?1=YES 0=NO输入1键盘显示:WALK TEST START1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:WALK TEST END1st 01 2nd 00输入01再按下*号键输入01再按下*号键键盘显示:QUIT REPORT MENU1=YES 0=NO按下1再按下0再按下0键盘显示:DEVICE PROG. ?1=YES 0=NO输入1键盘显示:DEVICE ADDRESS01-30,00=QUIT输入02按下*号键键盘显示:02DEVICE TYPENOT USED输入01按下*号键再按5下*号键键盘显示:DEVICE ADDRESS1-30,00=QUIT 03按下*号键键盘显示:03DEVICE TYPENOT USED输入06按*号键再按下0键盘显示:DEVICE ADDRESS1-30,00=QUIT 04输入00按下*号键键盘显示:QUIT MENU MODE1=YES 0=NO输入1键盘显示Program Mode*Fill# View-00输入*23键盘显示:Multiple Alarms-23输入1键盘发出叮叮叮三声输入*32键盘显示Prim.Subs. Acct#-32输入十九次0,1次1键盘发出叮叮叮三声输入*39键盘显示:Open/Close Rep.For Installer-39输入1键盘发出叮叮叮三声输入*56键盘显示:Dynamic SignalDelay -56输入00发出叮叮叮三声输入*57键盘显示Dynamic SignalPriority -57输入1发出叮叮叮三声输入*58键盘显示;:LRR CS#1Category En. -58输入六个1发出叮叮叮三声Zone Type 1-8Restore -79输入八个1发出叮叮叮三声输入*80键盘显示:Zn Types 9,10,16,14 Restore-80输入四下1发出叮叮叮三声输入*84键盘显示:SwingerSuppress . -84输入00发出叮叮叮三声输入*88键盘显示:Burg. Alarm Comm.Delay -88输入0发出叮叮叮三声输入*99二.防区模块编程进入编程:操作密码4140+8000 键盘显示: Program Mode*Fill# View-00进入报告编程:*93键盘显示ZONE PROG. ?1=YES 0=NOEnter Zone no.000=Quit 001输入防区号(总线防区从010开始)按两下*号键键盘显示:010Zone TypeNO RESPONSE 00输入防区类型(03为周界,07为24小时防区)按一下*号键键盘显示:010Partition1输入防区所在的子系统1-8按4下*号键键盘显示:010Input TypeNone 00输入类型06(t制)按四下*号键键盘显示:010 Input S/N:LAXXX-XXXX:1输入7位地址码和回路号(两防区模块有1号回路和2号回路之分,八防区模块都是1号回路)按三下*号键:Enter Zone no.000=Quit 0XX编剩余防区重复以上步骤,如要退出输入000按*号键再按1接着*99退出编程。
VISTA-128 主机进入编程手册

电话通讯部分编程:进入主机编程:41408000*93 0 0 1,进入报告码设置菜单(RERORT CODE PROG),0 1,进入REST,SUPV.CODE?输入001*01*01*01*01*01,输入000*,退出REST,SUPV.CODE? 0 1,进入SYSTEM GROUP #1?输入11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11* 0 1 进入SYSTEM GROUP #2?输入11*11*11*11*11*11*11*11*11*11* 0 1进入SYSTEM GROUP #3?输入11*11*11*11*11*11*11*11*11*11*11*11*11*11*11*11* 0 1进入SYSTEM GROUP #4?11*11*11*11* 1 1 退出报告码编程。
*09 进入延时#1,*10 外出延时#1,*11进入延时#2,*12 外出延时#2*13 警号发声时间设置*31 电话外线号码设置,没有不需要输入*32 主账号设置例如1234 输入01020304**33 主电话设置例如市局84209971**34 第二电话号码设置例如工行中心52344689**45 第一通讯格式输入1*47 第二通讯格式输入1*51双报告输入1*90第二通讯账号设置例如用户编号8888 ,输入08080808**39 输入1*45输入1*79输入1 1 1 1 1 1 1 1*80输入1 1 1 1*84 输入00;*88输入00若系统有多个子系统,责需要输入*91,跳转到不通的子系统。
*32*90防区编程部分41408000 进入主机编程1. 主机自身防区编程:在防区编程时应该有子系统的规划,就是每个子系统应该包含哪些防区。
这样在防区编程时就方便了。
2. 进入编程后显示:按*93 进入菜单编程,输入1 按*号确认进入下一步显示 "ZONE PROG?"输入1进入防区编程。
霍尼韦尔VISTA-128 250BPT安装手册(详细对照)

HoneywellVISTA-128BPT/VISTA-250BPT安装手册中安消技术有限公司李林目录一、设备认识 (3)Vista系列报警主机(以Vista 128BPT为例) (3)Vista系列报警主机控制键盘(6160) (7)4193SN/SNP单地址码两回路模块(已停产) (7)4293SN单防区扩充模块 (8)4101SN V-Plex单防区总线继电器模块 (9)4204ECP总线继电器模块 (9)4208SN V-Plex总线8防区扩充模块 (10)4297总线延伸器 (10)4232AP 32路继电器模组 (12)VPlex-VSI总线监测/隔离模块 (13)IP-2000 2.0网络接口模块 (14)二、主机编程 (17)防区编程: (17)删除防区: (21)子系统编程: (23)1.子系统数量划分: (23)2.子系统跳转功能设置: (23)3.防区子系统划分及布防延时更改 (24)继电器输出设备编程: (25)1.4101SN单防区继电器模块编程 (25)2.防区列表编程 (29)3.查看防区列表 (30)4.4232AP 32路继电器模块编程设置(VISTA 128BPT) (30)4100SN与IP2000模块编程: (31)IPM-VISTA SUPER II网络报警模块编程: (33)三、键盘日常使用操作 (37)1.布撤防操作 (37)2.子系统跳转 (37)四、主机常见问题解析 (38)五、键盘常见显示中英文对照表 (40)一、设备认识Vista系列报警主机(以Vista 128BPT为例)(图1)由原安定宝、C&K打底建立的Honeywell安防是全球最大的报警器材制造商,其制造的VISTA系列报警主机(图1)是业界最早、认可度最高的大型总线制报警主机,主要用来接收处理前端探测器发送回来的报警信号,是先进的多功能控制主机。
功能框图Vista - 128BPT常规接线方式Vista - 128BPT总线接线方式Vista - 128BPT无线接线方式Vista - 128BPT总线连接图表格(一):总线负载电流、线径与总线驱动距离的关系Vista系列报警主机控制键盘(6160)(图2)6160键盘(图2)用来给报警主机编程和防区布撤防相关操作4193SN/SNP单地址码两回路模块(已停产)4193SN用于总线扩充,可以扩展成2个回路:白色线与黄色线组成一个10K 电阻监测的回路或者黄色线与黑色线组成常闭回路;这两个回路任选其一,都是第一个防区;绿、黑线组成常闭形式的第二个防区,在编程时要注意防区回路选择。
Honeywell VISTA-128FB产品说明书

Designed to integrate seamlessly with CCTV , access control and Honeywell’s full range of fire and burglary components, the VISTA-128FB provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions and supports up to 128 zones/points using hardwired, wireless and addressable V-Plex ®technologies.A diverse line of Honeywell initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform. The VISTA-128FB has been designed to mount quickly and easily in an attack resistant cabinet and is available in 12V and 24V models.• Supports addressable V-Plex access control points using VistaKey (1 to 8 doors) • Supports up to 15 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV switcher module• Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire system annunciator• Stores up to 512 events and can accommodate 150 user codes • New E2 software simplifies programming• Easily programmed and maintained with newly upgraded Compass Downloader software• Eight hardwired zones standard,expandableto 120 V-Plexaddressable points/zones or 128wireless points/zones• Can control eight separate areas independently (8 partitions)• Two on-board notification (bell)circuits delivering 2.3A @ 12V or 3.4 amp @ 24V• Automatic smoke detector sensitivity maintenance testing* Connects to Honeywell’s Passpoint Access Control Systems. Maximum 32 doors.FEATURESVISTA-128FB/V128FB-24COMMERCIAL FIRE ANDPARTITIONED ALARM PLATFORMSPECIFICATIONS:• Cabinet dimensions- 18"H X 14.5"W X 4.3"D• Environmental- Storage temp: -14°F to 158°F(-10°C to 70°C)- Operating temp: -32°F to 122°F(0°C to 50°C)- Humidity: 85% RH• EMIMeets or exceeds the following requirements:- FCC Part 15, Class B Device- FCC Part 68- IEC EMC Directive• Agency ListingsBurglary- UL609 Grade A Local MercantilePremises and- Mercantile Safe and Vault- UL611/1610 Grades A, AA,Central Station- UL365 Grades A, AA PoliceConnect• Fire- UL864 FPA72 Local, CentralStation and Remote Station- Factory Mutual- California State Fire Marshal- MEA- UL985• Additional Features- Notification Appliance Circuits (two) - Programmable- Temporal code compliant- Individually silenceable- Programmable on-boardauxiliary relay- SIA false alarm reductionfeatures:- Exit Error Logic- Exit Delay Reset- Cross Zoning- Call Waiting Defeat- Recent Close Report - Supports commercial hardwired,addressable V-Plex polling loop andwireless zones- Hardwired zones:- Provides nine style B hardwiredzones- EOLR supervised for Fire andUL burglary installations- Supports N.0 or N.C. sensors- Individually assignable to oneor all eight partitions- Up to 16 two-wire smokedetectors each zone 1 and 2(32 total)- Up to 50 two-wire glass breakdetectors on zone eight- Patented addressable V-Plexpolling loopV-Plex technology:- Supports up to 120 two-wirezones/points- Global polling technology forfaster processing- Increased current drawcapacit (128mA)- Supervised by panel- Individually assignable topartitions, notification circuit(bell) output or aux relay- 4,000 ft capability without theuse of shielded cable- Extender/Isolation bus module- Two-wire smoke detectorzone/group expansion moduleadds two or four zones- Eight zone - Class A and BExtender Module- One zone supervised ContactMonitor Module- UL Listed wireless expansion- Supports up to 128wireless zones using 5881Receiver- Supervised by control for check-in signalss ta K ey V-Plex4293S N5881ENHCWireleCommercialReceiverCu s tom AlphaCon s oleRelayModuleNAC (Bell) CircuitPhone Line to Central7845C CellularNotification ApplianceNotification Appliance s6220B Hardware Zone sVi4278EX 9500S N4101S N4208S NF4208UOptionSPECIFICATIONS:- Tamper protection for transmitter - Individually assignable up to eight partitions- Supports UL864 FPA approved wireless smoke\ndetectors - Access control integration- Full integration with PassPoint - Access Control System Complete Gateway in access functions - Event reporting- Local printer of access or VISTA related event- Scheduled uploading of events to central station- Stored events for one call retrieval - Communication- Phone mapping by zone response type- Supports VIP Interactive PhoneVoice Module- Panel operation during download- Uploading equipment list to central station- Communication to PassPoint via Vista Gateway Module (VGM)• ApplicationsSupported by a diverse line of Honeywell initiating devices, the powerful VISTA-128FB is the ideal integrated fire and burglary control for applications where a higher level of security is necessary includingmedical and professional buildings,supermarkets, churches andsynagogues, office buildings, schools,universities, strip malls, largerresidences and factory or warehouse environments.• InstallationThe VISTA-128FB alarm system has been designed to mount both quickly and easily in an attack resistant cabinet. It meets all applicable requirements for UL commercial burglary installations.• Electrical:- Primary power:******************- Quiescent current draw:- 350mA- Backup battery- 12VDC, 12AH min to 34AAH max- Lead acid battery (gel type)- Alarm power- 12VDC, 1.7A max for each notification (bell) circuit output - Aux. standby power - 12VDC, 1A max - Total power- 2.3A at 12VDC, 3.4A at 24VDC from all sources - Standby time- 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34AAH battery - Fusing- Battery input, aux. andnotification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited.- Main dialer - Line seize:- Double Pole • Ringer equiv.- 0.713• Formats- ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID,Sescoa and RadionicsNotification Receiver32 Character ed 4209U 4193S N 5808W3VGM (PTVGM)5890Wirele ss PIRPa ss PointQuad PIR5808W3Detector s5816Door/Window Hold-Up S witchQ2260S N Multiplex 4190S N V-Plex Two-ZoneExpander4944S N S upport s Up To 645817CB Wirele ss Commercial mitterConventional Two-WireORDERINGVISTA-128FB Commercial Fire and Partitioned Burglary Alarm Platform 12V Model V128FB-24Commercial Fire and Partitioned Burglary Alarm Platform 24V ModelVISTA-128FB/V128FB-24COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORMSPECIFICATIONS:• Auxiliary devices- 6160CR Alpha Keypad Commercial Fire - 6139R - Red Alpha Keypad/Annunciator- FSA-8 & FSA-24 Fire System Annunciator- 4204 - Relay Module, four form C contacts- 4204CF - Two supervised output circuits- 6220S - System printer used with 4100SM Serial Interface Module - 5140DLM, FSA-8, FSA-24,FSAKSM Fire Annunciator • Two-wire and four-wire smoke detectors conventional- System Sensor smoke detectors • Horn/Strobes- System Sensor notification appliances • Manual pull stations - 5140MPS-1- 5140MPS-2• V-Plex (addressable) devices- 4101SN Single Relay/Zone Module - 4190SN Remote Point Module -two zones- 4190WH Two Point Multiplex RPM - 4193SN Two Zone Serial Interface Module- 4208U Loop Expansion Module -eight zones- 4208SNF Class A/13 Expander Module- 4209U Group Zoning Module -two/four zones- 4293SN One Zone Serial Interface Module- 4297 Isolation/Extender Module • V-Plex (addressable) smoke detectors - 5192SD - 5192SDT• Passive infrared detectors - 998MX- 4275EX-SN - 4278EX-SN - Quest 2260SN• V-Plex (addressable) contacts - 4939SN-WH - 4944SN-WH - 4959SN• Glassbreak detectors - 9500SN• VISTA Interactive Phone Module - 4286 Voice Module• Optional 24V power supply- PS24 - 24V power supply - 3.4A • Long range radio- Long range radio 7720ULF-XX,7845C, 7835CFPK • Upgraded software- Upgraded Compass Downloader Windows compatible• Wireless devices - 5804 - Wireless Key- 5804BD - Bi-Directional Key- 5804BDV - Bi-Directional with voice - 5816 - Door/Window Transmitter - 5819 - Shock Sensor- 5827BD - Bi-Directional Keypad - 5849 - Glassbreak Detector - 5881 Series - RF Receiversupporting 5800 wireless detectors - 5890 - PIR• Access control- VistaKey V-Plex (addressable)Access Control- VistaKey-SK Starter Kit - VistaKey-EX Expansion Kit - VGM Vista Gateway Module to PassPoint Access Control (Honeywell Access Systems)• CCTV- VistaView-100-CCTV Switch Module • Commercial wireless devices - 5869 - Hold up Transmitter - 5817CB - Wireless Commercial Transmitter- 5881ENHC - Commercial Fire/Burg Receiver- 5808W3 - Wireless Smoke Detector - 5809 - Wireless Heat DetectorL/VIS128FB/D May 2009© 2009 Honeywell International Inc.For more information: /security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100Melville, NY 11747 1.800.467.5875。
VISTA128BPT+IPM-VISTA模块软件设置

1,主机和IPM模块的连接:12V+ 接到主机的6上GND 接到主机的7上ECP/0 接到主机的8上ECP/I 接到主机的9上2,主机的编程:4140 8000进入编程*56 00*57 1*58 1 1 1 1 1 1*59 1 1 1 1 1 1*79 1 1 1 1 1 1 1 1*80 1 1 1 1*84 0 0*88 0*93 0 0 0 0 102 * 01 * * * * * *(直至右下角显示03)再输入* 06 * 1 * (直至右下角显示04)00 * 1 *99退出编程即可3.软件的设置输入用户ID,admin密码为空,点确定进入点配置管理输入ID,admin,密码为空,进入之后点硬件配置右键点报警子系统点增加模块选择IPM23/IPM-VISTA选中之后,右边的搜索就可以点了,点搜索之后会出现局域网里的所有模块,如只接了一个,那只有一个,前边方框打钩然后点确定全防密码写主密码4140主机类型选择为IPM-VISTA然后点确定可以展开看一下里面有子系统,子系统下面,有防区在IPM那里点右键,增加的模块为子系统,在子系统那里点右键,增加的模块为防区这里以一个子系统为例,双击子系统在子系统密码那里输入4140这样就配置完成了,把软件整个关闭,重新启动,即可这里就出现我们刚刚添加的模块,如果模块的IP地址设置正确的话,就可以正常通讯了正常通讯后,子系统图标会变成绿色双击IPM模块,稍等片刻就会出现虚拟键盘,此虚拟键盘和报警主机的物理键盘几乎同,返控操作就在虚拟键盘上进行比如想要布防,直接在虚拟键盘上点41402即可此时,键盘显示会显示为布防,同时键盘右下角会显示你输入的键同时,会有信息上传至软件这样,基本就通讯正常了设置地图部分点左上角的电子地图然后点编辑地图右键点new PAGE点编辑属性页面名称可根据实际情况填写点背景图选择你的地图文件-打开点确定点右边的报警模块类,选择防区鼠标会变成一个小十字,此时,鼠标在地图上点击一下就添加一个防区加完之后,右键鼠标,鼠标会变成正常的小箭头防区也就加完了,下面还需要关联防区,选择一个防区双击选择关联模块从这里选择关联防区点确定即可这样把防区全部关联好,再用鼠标拖至相应的位置最后,点保存,退出。
Vista128BPT_250bpt

–5–
编程地址索引
编程地址按编号顺序排列,使用本索引与编程地址表相互参照。 地址 ∗00 ∗04 ∗05 ∗06 ∗09 ∗10 ∗11 ∗12 ∗13 ∗14 ∗15 ∗16 ∗17 ∗19 ∗20 ∗21 ∗22 ∗23 ∗24 ∗25 ∗26 ∗27 ∗28 ∗29 ∗30 ∗31 ∗32 ∗33 ∗34 ∗35 ∗36 ∗37 ∗38 ∗39 ∗40 ∗41 ∗42 ∗44 组 系统通用 系统通用 系统通用 子系统专有 子系统专有 子系统专有 子系统专有 子系统专有 子系统专有 系统通用 系统通用 子系统专有 系统通用 系统通用 系统通用 系统通用 子系统专有 子系统专有 系统通用 系统通用 通信 通信 系统通用 子系统专有 通信 通信 子系统专有 通信 通信 系统通用 系统通用 系统通用 子系统专有 子系统专有 通信 系统通用 通信 通信 地址 ∗45 ∗47 ∗51 ∗56 ∗57 ∗58 ∗59 ∗79 ∗80 ∗83 ∗84 ∗85 ∗88 ∗89 ∗90 1∗07 1∗11 1∗15 1∗17 1∗18 1∗19 1∗20 1∗21 1∗22 1∗23 1∗24 1∗25 1∗26 1∗28 1∗29 1∗30 1∗31 1∗34 1∗35 1∗42 1∗43 1∗44 1∗45 组 通信 通信 通信 通信 通信 通信 通信 通信 通信 通信 子系统专有 子系统专系统通用 子系统专有 子系统专有 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 子系统专有 系统通用 系统通用 系统通用 系统通用 通信 通信 通信 子系统专有 系统通用 子系统专有 地址 1∗46 1∗47 1∗48 1∗49 1∗52 1∗53 1∗55 1∗56 1∗57 1∗58 1∗60 1∗70 1∗71 1∗72 1∗74 1∗75 1∗76 1∗77 1∗78 1∗79 1∗80 2∗00 2∗01 2∗02 2∗05 2∗06 2∗07 2∗08 2∗09 2∗10 2∗11 2∗18 2∗19 2∗22 2∗23 2∗24 组 系统通用 子系统专有 系统通用 系统通用 子系统专有 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 子系统专有 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 系统通用 子系统专有 子系统专有 子系统专有 子系统专有 子系统专有 子系统专有 系统通用 子系统专有 系统通用 子系统专有 子系统专有 子系统专有
IPM-VISTA SUPER II用户操作手册

192.168.0.10 255.255.255.0 192.168.0.1 0 Disable 2 0 30 seconds IP/PSTN dual report Dual report 192.168.0.2 3000 Always ON Disable 192.168.0.4 3000 192.168.0.3 3000 Disable Disable 192.168.0.5 3000
x 10/100M adaptive network port x Voltage: DC 12V-15V x Current: 80 mA-100 mA
x Online upgrade x IPM Configuration Tools x Power supply from control panel, easy
Connections to Vista Series Control Panel
Default Settings
To restore the default settings, place the jumper on J1 and then power up the control panel. After CR10 starts to flicker, cut the jumper. Refer to the following table for the default settings:
x Alarms (ContactID) via TCP/IP network x Remote controlling and programming
Vista control panels x Dual CMS solution x Static IP and DHCP
Specifications
VISTA128BPT高级模式防区编程

VISTA-128专家模式防区编程指南(简)用新键盘时上电: 1 3 (同时按)数秒后当键盘显示ADD=31按01* (更改键盘地址为01)当键盘显示**DISARMED**READY TO ARM界面时即可编程进入编程输入:41408000键盘显示:Program Mode*Fill # View更改系统延时输入09 00(输入正确,系统会响铃确认)10 0011 0012 00 (四个延迟时间相通过输入00关闭)防区编程输入:*93输入:0 不进入防区编程1 进入专家模式0 不确认出现:说明:ZN:是防区号。
ZT:是防区类型。
P:是子系统(霍尼的总线主机一般最多分8个子系统)。
RC:是报告码(要上报信息到中心的时候需要)。
IN:是防区输入类型。
L:是设备的回路号。
在ZN下方输入:011 * (对011号防区编程)在ZT下方输入:03 * 07(24小时有声防区)/03(周边窃警防区)在P 下方输入: 1 * 子系统号在RC下方输入:* 跳过(直接跳过)在IN 下方输入:06 * 06为序列号设备(4193.4208.4101都是06)然后一直按*直到看到:AXXX-XXXX输入:023-4235 * (输入防区的7位数字序列号)在L 下方输入: 1 * (回路号4193防区黄黑是1,绿黑是2。
4208全是1 )防区输入完后,在ZN下方输入:000 *000=QUIT 001输入000,问是否要退出0=NO 1=YES输入:1出现:PROGRAM MODEFILL*VIEW输入:*99退出然后等待系统自动重启,大概需要2分钟时间用户码:1234 安装员码:4140布防:密码+2撤防:密码+1报警后需要撤防2次第一次撤防是停止报警第二次是消除报警记录旁路:密码+6+# 自动旁路所以有问题的防区单防区旁路:密码+三位防区号(001-250)+#连续旁路操作:密码+防区号+防区号。
#。
Windows Vista 使用指南说明书

More Information n Windows Vista—Instant Search: /windows/products/windowsvista/ features/details/instantsearch.mspx
Lost track of what files and programs you’ve opened? Flip through all your open files and windows with Windows Flip 3D—you’re just one click away from everything you’re working on. Use the Windows logo key (sometimes called “Start”)+TAB key to open the 3-D view, then flip through open windows by using arrow keys or the scroll wheel on your mouse to quickly identify and select the one you want. Navigating your desktop has never been this fun!
Learn more about how you can use Windows to simplify your life with Windows Guides
VISTA-128-250简要说明

电话 线入
16.5V/AC 变压器
所有键盘距离之 和不超过500米。 其他如继电器模 块、无线设备等 连接方法一样
5804
5890
5816
16
霍尼韦尔报警控制主机——VISTA-128BPT总线回路
• 总线回路本身提供最大128mA电流。负载电流越小、总线驱动距离越长 • 采用非屏蔽双绞线。线径越大、总线驱动距离越长。 • 可以采用简洁的星型连接。安装时要注意极性。 • 每个总线设备都有其唯一的地址码供主机识别,不用通过拨码开关设定, 地址码不会重复 。 • 总线长度总和不能超过3658米 (屏蔽线减半)。 • 4297模块可以用来为总线回路提供额外的128mA电流,从而延伸总线回 路长度达到3658米。 并隔离不同区段的总线,避免一个区段的总线短路影 响其它区段; • 一台VISTA-128BPT可以最多并连8个4297模块 (注意:4297 不能串 连)。 • VPlex-VSI 模块可以用来监测V-Plex总线上的故障,点亮LED报告故障, 并隔离该段总线,主机会显示故障地址模块的错误信息。VPlex-VSI的数量 不限,可以串联或并联
最多8条总线 没有 1X 1200bps Compass 1.6 需增加4100SM模块
报警系统简单工作描述
控制主机——对探测器传来的信号进行判断,按预定编程通过相应 设备(键盘、警号、闪灯、电话、网络)做出反应。 探测器——对有效范围内环境随时进行监视,发现异常立即向 控制器发送信号。 电源——向控制器、探测器提供电源,保证系统的正常运行。 键盘——控制主机的输入、输出设备,用于显示状态、操控主机 和向主机输入程序数据。 探测器 控制主机 键盘 通讯模块
表格二 (常用模块的总线负载)
模块 4193SN 4193SNP 4293SN 4101SN 4208SN VPLEX-VSI 负载 1.5mA 1.7mA 1.0mA 7.0mA 0.6mA 1.2mA 采用独立供电时 LED 亮时:5.0mA 备注
霍尼韦尔Vista-128BPT报警主机编程说明常用版-工程服务部编辑

Honeywell霍尼韦尔VISTA系列报警主机编程说明深圳市麦驰物联股份有限公司整理编辑-工程服务部目录一、设备认识 (3)Vista系列报警主机(以Vista 128BPT为例) (3)Vista系列报警主机控制键盘(6160) (7)4193SN/SNP单地址码两回路模块(已停产) (7)4293SN单防区扩充模块 (8)4101SN V-Plex单防区总线继电器模块 (9)4204ECP总线继电器模块 (9)4208SN V-Plex总线8防区扩充模块 (10)4297总线延伸器 (10)4232AP 32路继电器模组 (12)VPlex-VSI总线监测/隔离模块 (13)IP-2000 2.0网络接口模块 (14)二、主机编程 (17)防区编程: (17)删除防区: (21)子系统编程: (23)1.子系统数量划分: (23)2.子系统跳转功能设置: (23)3.防区子系统划分及布防延时更改 (24)继电器输出设备编程: (25)1.4101SN单防区继电器模块编程 (25)2.防区列表编程 (29)3.查看防区列表 (30)4.4232AP 32路继电器模块编程设置(VISTA 128BPT) (30)4100SN与IP2000模块编程: (31)三、键盘日常使用操作 (33)1.布撤防操作 (33)2.子系统跳转 (33)四、主机常见问题解析 (34)一、设备认识Vista系列报警主机(以Vista 128BPT为例)(图1)由原安定宝、C&K打底建立的Honeywell安防是全球最大的报警器材制造商,其制造的VISTA系列报警主机是业界最早、认可度最高的大型总)1(图线制报警主机,主要用来接收处理前端探测器发送回来的报警信号,是先进的多功能控制主机。
功能框图常规接线方式Vista - 128BPT总线接线方式Vista -128BPT.无线接线方式Vista - 128BPT总线连接图Vista -128BPT.表格(一):总线负载电流、线径与总线驱动距离的关系Vista系列报警主机控制键盘(6160)(图2)6160键盘用来给报警主机编程和防区布撤防相关操作)2(图4193SN/SNP单地址码两回路模块(已停产)4193SN用于总线扩充,可以扩展成2个回路:白色线与黄色线组成一个10K电阻监测的回路或者黄色线与黑色线组成常闭回路;这两个回路任选其一,都是第一个防区;绿、黑线组成常闭形式的第二个防区,在编程时要注意防区回路选择。
VISTA128BPT、250BPT编程说明

按键内容
1 按41408000进入编程
3 按* 93进入防区编程模式
4 按 * * * * 四次
5 按1
6 按 * (默认一号键盘)
7 按*
8 键盘02
9 TYPE 改01
10
11
12 TYPE 改01
13
14 按2****,屏幕显示
15 按00*1*99结束
键盘设置
键盘显示内容
Program Mode *Fill
1 同时按住1和3,界面右下角显示31,这时可以输入键盘号01
CON ADDR=31 输入01
2 同时按住1和3,界面右下角显示31,这时可以输入键盘号02
CON ADDR=31 输入02
设置
内容说明
6160(键盘1),(控制室子系统1内的防区)
左边1指控制的分区(子系统1),9全控 6148(键盘2),(控制室子系统2内的防区)
#View-00
ZONE PROG ?
1=YES 0=NO 0
DEVICE PROG
1=YES 0=NO
DEVICE ADDRESS
01-31, 00=QUIT 01
01 DEVICE TYPE
NOT USED 01
01 CONSOLE PART
.
1
DEVICE ADDRESS
01-31, 00=QUIT 02
02 DEVICE TYPE
NOT USED 01
02 CONSOLE PART
.
2
DEVICE ADDRESS
01-31, 00=QUIT 03
02 DEVICE TYPE
NOT USED O1
02 CONSห้องสมุดไป่ตู้LE PART
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
电路板上接线(Hardwire)001—009防区可以使用,编号01;
受监控无线(RF Xmitter)编号03;
不受监控无线(Unsupevsd)编号04;
无线按钮类型(Button RF)编号05;
序号式总线(Serial Poll)使用4193SN和4293SN,编号06;
输入00*返回键盘显示QUIT MENU MODE?
1=YES 0=NO 0
输入1返回键盘显示Program Mode
*Fill # View-00
输入*99返回键盘绿灯亮,显示***DISARMED***
READY TO ARM
主机开始自检,约两分钟后,键盘绿灯亮的情况下,可以布防,试验001防区
A XXX-XXXX:1
L下方输入010防区占用此4193SN的回路的序号,4193SN有两个回路,黄—黑为第一回路,绿—黑为第二回路
从4193SN线接在一起的三根线中抽出黄线,VISTA 120会自动读出这个4193SN的地址码并显示在键盘上,这个地址码与4193SN上粘贴的数码一致。
按*键盘显示010ZONE RESPONSE
NO RESPONSE
根据用户需要输入防区类型,现以周边防区(03)为例
输入03*键盘显示:010 ZONE RESPONSE
PERIMETER 03(可选03或者07)
按*键盘显示:010PARTITION
1
010防区所属第一子系统(划分多个子系统时,输入该防区的子系统号)
001定为设定周边防区
按*键盘显示:001 PARTITION
1
001所属第一子系统(划分多个子系统时,输入该防区的子系统号)
按*键盘显示:001 REPORT CODE
1st00 2nd 00 00
此项设定001防区通讯码,1st输入11向第一报警中心发送报警信息
2nd输入11向第二报警中心发送报警信息
VISTAR—120简易编程操作手册
防区编程
一、设置6139编程键盘地址为01
开机同时按1 3键5秒,键盘显示Addr=31或Addr=xx,输入01按*
键盘绿灯亮,显示***DISARMED***
READYTO ARM
键盘地址为00时,完成编程后可能会出现键盘不能操作,6148键盘不能编程
二、设置每个防区
编号03—周边防区,布防时有效,撤防时无效;
编号04—内部防区,留守布防时无效,外出布防时有效,撤防时无效;
编号06—24小时无声防区;
编号07—24小时有声防区;
编号09—火警防区;
编号00—无用防区。
其他防区类型的编号请参照英文手册。
输入03键盘显示:001 ZONE RESPONSE
PERIMETER 03
*Fill # View
按*93键盘显示ZONE PROG
1=TES 0=NO
按1进入防区编程
键盘显示SET TO CONFIRM?
1=YES 0=NO
输入1,按*
键盘显示ENTER ZONE NO.
000=QUIT 001
输入01(以001防区为例),按*
键盘显示001 ZT P RC IN:L
09 1———
目前显示的是001防区的信息,按*
键盘显示001ZONE RESPONSE
Fire 09
目前001防区为火警防区,请根据具体情况输入防区类型的编号
编号01—出入口防区1型,布防时有延时,进入时有延时,延时时间由*09和*10设定;
编号02—出入口防区2型,布防时有延时,进入时有延时,延时时间由*11和*12设定;
按*93键盘显示:ZONE PROG
1=YES 0=NO
按1进入防区编程
键盘显示SET TO CONFIRM?
1=YES 0=NO
输入1,按*
键盘显示ENTER ZONE NO.
000=QUIT 001
输入010(以010防区为例)*
键盘显示010 ZT P RC IN:L
00 1———
目前显示的是010防区的信息
双向开关式总线(Dip SW Poll)使用4208U编号07;
(一)设置电路板上接线(Hardwire)防区,以001防区为例
先将随机配的2K电阻按接线图接在VISTA—120的端子上
进入编程模式
输入4140 8000(4140为出厂设置的安装员密码)
进入编程模式,键盘显示:Program Mode
1、使用பைடு நூலகம்193SN双回路总线编址器时(以010,011防区为例):
将4193SN的红线接入VISTA 120接线端子的24,
黑线接入VISTA 120接线端子的25,
另外三根线(黑,黄,绿)接在一起,白线不用。
输入4140 8000进入编程模式键盘显示:Program Mode
*Fill # View
请输入防区接入类型的编号06 *:键盘显示:010INPUT
Serial Poll 06
按*键盘显示:010 SMART CONTACT
1=YES 0=NO 0
按*键盘显示:010V-PLEX RELAY
1=YES 0=NO 0
按*键盘显示:010 DOOR #
(01-15)00
按*
键盘显示:010INPUT S/N:L
按*键盘显示:010 REPORT CODE
1 st 00 2nd 00 00
此项设定010防区通讯码,1 st 11向第一报警中心发送报警信息
2 nd11向第二报警中心发送报警信息
按***键盘显示:010INPUT TYPE
00
此项设定010防区的接入类型,06表示序号式总线(使用4193SN和4293SN)
按*键盘显示:001INPUT TYPE
Hardwire 01
此项设定001防区的接入类型,请输入防区接入类型的编号:
按*键盘显示:001 ZT P RC IN:L
03 1——HW 1
目前显示的是001防区的信息,
按*键盘显示ENTER ZONE NO .
000=QUIT 002
输入下一个防区的信息,如果不输入下一个防区的信息,(002—009防区不用时应将防区类型输入00)
输入4140 2进入外出延时布防,键盘蜂鸣器响,将联接001愤怒过去的2K电阻拆下,主机将报警,键盘显示:ALARM 001表示001防区报警。
输入4140 1 4140 1,主机将停止报警,将联接001防区的2K电阻重新接好,001防区试验完成。
(二)设置使用序号式总线(使用4193SN和4293SN)联接的防区