变电站主接线一次接线图

合集下载

变电站电气主接线图

变电站电气主接线图

第5、6章图形,.2×8MW(a)2×10MVA1G G1TG2G2T110KV 35KV2×8MW(b)20MVAG1G 2GG110KV2T2G(c)2×8MW2×10MVAG1G 1T G35KVTMY-100X8ZN21-10/1250配CD10ⅢLZZBJ-101000/5 0.5/10P 2×(ZR-YJV 22-6/3×240)RN2-6/0.5ASFWG8000-6/4950Ue=6.3kV Ie=916.45A COSφ=0.8LZX-10Q800/5 0.5/10PJ Y N 2-10-03(改)1G励磁变(厂家配套)励磁互感器(厂家配套)JDJ-6 36 0.1√3√J Y N 2-10-17J Y N 2-10-18RN2-6/0.5A 36 0.1 0.1JDZJ-63√√3J Y N 2-10-20√ 6 0.1 0.1√333JDZJ-6RN2-6/0.5AHY5WZ-10/302G同左ZN21-10/2500配CD10ⅢLFZJ-102000/5 0.5/0.5/10/10PJ Y N 2-10-03SF9-20000/110Y,d11121±3×2.5%/6.3kV U k %=10.5%LGJ-120GW4-110DW/630左接地LW25-1261250A,40kA GW4-110DW/630双接地LCWB 6-110100/50.2/0.5/10P/10PTYD-110/ -0.07H 3√LRD-60-B 50/5GW4-110DW/630双接地JDCF-110Y5W1-100/260√110 0.1 0.13√√33GW 13-60G/400Y1W-73/15ZN21-10/630配CD10ⅢLZZBJ-10100/5 0.5/10PJ Y N 2-10-03ZR-YJV 22-6/3×50SC9-800/6.3D,yn116.3±5%/0.4kV Ud%=7LMZ1-0.5 1200/5LMZ1-0.5 1200/5SC9-800/10D,yn1110±5%/0.4kV Ud%=7ZR-YJV 22-10/3×50LZZBJ-10100/5 0.5/10PZN21-10/630配CD10ⅢJ Y N 2-10-06(改)ZR-YJV 22-10/3×5010kV外来电源J Y N 2-10-19JDZJ-10HY5WZ-17/51RN2-10/0.5A10/0.1kV0.4kVLMY100×8-40×8DW15-1200DW15-1200DW15-12000.1LMY100×8-40×8G~G~TMY-100X8GW4-110DW/630左接地图5-19 某水电站电气主接线全图图5-20 地区变电所接线8回35kV220kV4 回2×120MVA至无功补偿装置6 回2×60MVA4回2×10MVA1T图5-21 终端变电所接线4回10kV2T110kV 35kVVV22-13×50+1×251#厂变进线V 42L6-A,0~150A DT864-2,380/220V,3(6A)42L6-V,0~450V说明:BT95O9为事故照明切换板,其直流电源用VV22-1-2×4电缆引至直流屏。

电站变电所电气主接线图(含说明)

电站变电所电气主接线图(含说明)
220kV I母220kV II母110kV套管CT:3(TMY-125X10)HY5WZ-17/45W110kV中性点设备:YH1.5W-72/186WLJW1-10W,400/1AGW13-63W/630LRB-110,200,400,600/1A,(两只)LRB-60,200,400,600/1A,(两只)LR-110,1200,1800,2400/1A,(一组)LRB-110,1200,1800,2400/1A,(两组)GW13-110W/630ALJW1-10W,200/1AYH1.5W-144/320W220kV中性点设备:110kV中性点套管CT:220kV中性点套管CT:2xLGJX-500/45YH10W-108/281WYH10W-204/532WLRB-220,800,1200,1600/1A,(两组)LR-220,800,1200,1600/1A,(一组)Uk1-2=14% Uk1-3=50% Uk2-3=35%220%%P8X1.5%/115/10.5kV#1主变压器容量比:180/180/90 接线组别:YN,Yno,dll220kV套管CT:SFSZ9-K-180000/2200.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2x600/1A2500A,50kA5P30/5P30电流互感器GW7-220IID(W)5P30/5P30/5P30C备用一BA出线二BCLGJX-630/55A#1主变间隔C备用三变主2xLGJX-500/45YH10W-108/281WYH10W-204/532W#2主变压器#1同(预留)#3主变压器(预留)#4主变压器#3主变间隔#2主变间隔#4主变间隔备用四CBABALDRE-130/116LDRE-130/116变主#1同隔间母联2x(LGJX-630/55)5P30/5P30/5P305P30/5P30/0.52x1200/1A电流互感器弹簧机构4000A,50kA断路器GW16-220D(W)2500A,50kA氧化锌避雷器LGJX-400/352500A,50kAGW16-220D(W)YH10W-204/532WTYD-220/ 3-0.0075H电压互感器(三相)220/ 3:0.1/ 3:0.1/ 3:0.1/ 3:0.1一同出线出线一BCA5P30/5P30/5P300.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2500A,50kA5P30/5P302x1200/1A电流互感器GW7-220IID(W)B、C相:OWF-220/ 3-0.005HA相:TYD-220/ 3-0.005HXZK-1600-1.0/40XZK-1600-0.5/402x(LGJX-400/35) I母母线设备II母母线设备设母同 I母线备SC11-400/11LGJX-300/40LDRE-130/116LDRE-130/1162000A,40kAGW4-126IID(W)GW16-126(W)GW16-126D(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P302x400/1A电流互感器3150A,40kA弹簧机构TYD-110/ 3-0.01H断路器A相:ACBCBA出线二出线一#1主变一出同线一出同线一同出线TBB22-10-100205组/334M-2BLXGN2B-12(Z)XHDCB-500/11DKSC-500/11 500kVA,ZN#1接地变10kV I段 3(TMY-125X10)XGN2B-12(Z)XGN2B-12(Z)#1母设10回#1站用变XGN2B-12(Z)ABCBAC出线三出线四#2主变同一出同线变#1主CBA#3母设#4母设10kV IV段10kV III段#3接地变#4接地变母联 Ⅱ母母线设备 Ⅲ母母线设备110kV Ⅰ母110kV Ⅳ母110kV Ⅱ母110kV Ⅲ母分段10回TBB22-10-100205组/334M-2BLTBB22-10-80165组/334M-2BL Ⅳ母母线设备 Ⅰ母母线设备2000A,40kALGJX-240/30TYD-110/ 3-0.02HYH10W-108/281W0.1/ 3:0.1/ 3:0.1220/ 3:0.1/ 3:GW4-126D(W)设母同 I母线备2000A,40kAGW16-126D(W)断路器3150A,40kA5P30/0.5/0.2S5P30/5P302xLGJX-500/45弹簧机构2x600/1A电流互感器母联CBACBA出线五#3主变ABC出线六一同出线断路器2xLGJX-500/453150A,40kAGW4-126IID(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P30弹簧机构2x600/1A电流互感器2000A,40kAGW16-126D(W)GW16-126(W)备用 CBA#4主变备用 CBA备用 CBA出线七CBA备用4回一同出线图中实线设备为本期建设部分,虚线设备为预留扩建部分。说 明:3(TMY-125X10)YH10W-108/281W10kV IIA段 3(TMY-125X10)线5回馈母同I#2A母设设母同#1#2接地变器同I母电容#2站用变变#1同接地变站同#1TBB22-10-100203组/334M-2BLTBB22-10-100202组/334M-2BL10kV IIB段 3(TMY-125X10)器同I母电容5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台LZZBJ9-10Q,400~600~800/15P20/0.5/0.2S 15VA, 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只LZZBJ9-10Q,800/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)ZR-YJV22-8.7/15-1*400GN30-10D/1250A,31.5kA,1组10/√3:0.1/√3:0.1/√3:0.1kV0.2/0.5/3P 30/40/150VA HY5WZ-17/45 1组LZZBJ9-10Q,150/1 ,5P20பைடு நூலகம்0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)LZZBJ9-10Q,150/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)XGN2B-12(Z)ZN28-4000-50kAGN30-10/4000A, 1台50kA,1组ZR-YJV22-8.7/15-3*240ZR-YJV22-8.7/15-3*240XGN2B-12(Z)5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台#2B母设设母同#1线5回馈母同IJW6-252W/630AJW6-252W/630A电流互感器2x600/1A5P30/5P305P30/0.5/0.2S断路器,弹簧机构3150A,40kAGW4-126D(W)2000A,40kAGW4-126D(W)2000A,40kA11%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11SC11-400/1111%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11设母同 I母线备设母同 I母线备母同 I母联C备用二BA2006.04.25例比APPROVED BY审 定AUDITED BY核 定设 计DESIGNED BYCHECKED BY校 核NO图 名图号TITLEPROJECT工程名施工时间TIME审 核AUDITED BY设计阶段220kV XX变电站 工程电气主接线图专业会签日期专业会签日期QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

什么叫做电气接线图?怎样区分一次接线图和二次接线图?

什么叫做电气接线图?怎样区分一次接线图和二次接线图?

什么叫做电气接线图?怎样区分一次接线图和二次接线图?
按照国家颁布的有关电气技术标准,使用电气系统图形符号和文字符号表示电气装置中的各元件及其相互联系的工程图,称为电气连接图,又叫电气线路图。

电气连接图按其在电力系统中的作用,可分为一次接线图和二次接线图。

1、一次接线图也叫主接线图,是表示电能输送和电能分配路线的接线图。

与一次接线直接相连的电气设备,称为一次设备或一次元件。

一次接线图一般用单线绘出,图中的设备(如开关)位置都是无电压时的位置。

如图所示是低压配电的一次接线图,包括以下三个单元:
第一个单元由配电变压器T、电流互感器(三只)1TA、刀开关1QS、自动空气开关1QF和连接导线组成,它是电能输入部分。

第二个单元由刀开关2QS、电流互感器(三只)2TA、自动空气开关(四只)2QF~5QF和连接导线组成。

第三个单元由刀开关2QS、熔断器1FU和2FU、电流互感器(单只)3TA和4TA及连接导线组成。

第二个单元和第三个单元是电能输出(分配)部分。

T、1TA、1QS、1QF等都是一次设备。

2、二次接线图上述一次接线图所绘出的三个单元,只表明电能输送和分配,而未表明电路的控制、指示、监视、测量和保护。

表明电路的控制、指示、监视、测量和保护电器正常运行的接线图,称为二次接线图,也叫副接线图。

与二次接线直接相连的电器,称为二次设备或二次元件。

二次接线图往往只绘出一次连线图中的一个单元的某一元件。


一参量或表明某一功能。

例如,图2是图1中电能输入单元的电流互感器1TA(电流参量)的电流测量二次接线图。

由该图可见.电流表A就是二次元件。

变电站主接线图(解释)

变电站主接线图(解释)

变电站一次系统图1、单母线接线特点:只有一组母线,所有电源回路和出线回路,均经过必要的开关电器连接到该母线上并列运行。

主要优点:接线简单、清晰,所用电气设备少,操作方便,配电装置造价便宜。

主要缺点:适应性差,母线故障或检修,全部回路均需停电;任一回路断路器检修,该回路停电。

适用范围:单电源的发电厂和变电所,且出线回路数少,用户对供电可靠性要求不高的场合;10kV纯无功补偿设备出线(电容器、电抗器)。

2、单母线分段接线特点:与单母线接线方法相比,增加了分段断路器,将母线适当分段。

当对可靠性要求不高时,也可利用分段隔离开关进行分段。

母线分段的数目,决定于电源的数目,容量、出线回数,运行要求等。

母线分段一般分为2-3段。

优点:母线发生故障时,仅故障母线段停电,缩小停电范围;对重要用户由两侧共同供电,提高供电可靠性;缺点:当一段母线故障或检修时,与该段所连的所有电源和出线均需断开,单回供电用户要停电;任一出线断路器检修,该回路要停电。

适用:6~10kV,出线6回以上;35~66kV,出线不超过8回时;110~220kV,出线不超过4回时。

3、单母线分段带旁路母线接线优点:增设旁路母线,增设各出线回路中相应的旁路隔离开关,解决出线断路器检修时的停电问题。

为了节省投资,可不专设旁路断路器,而用母线分段断路器兼作旁路断路器。

因为电压越高,断路器检修所需的时间越长,停电损失越大,因此旁路母线多用于35kV以上接线。

适用:6~10kV接线一般不设旁路母线;35~66kV,可设不专设旁路断路器的旁路母线;110kV出线6回以上,220 kV出线4回以上,宜用专设旁路断路器的旁路母线;出线断路器使用可靠性较高的SF6断路器时,可不设旁路母线。

4、双母线接线优点:两条母线互为备用,一条母线检修时,另一条母线可以继续工作,不会中断对用户的供电;任一母线侧隔离开关检修时,只需断开这一回路即可;工作母线故障时,所有回路能迅速切换至备用母线而恢复供电;可将个别回路单独接在备用母线上进行特殊工作或试验;因而可靠性高,运行方式灵活,便于扩建。

变电站电气主接线图

变电站电气主接线图

精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理学习帮手2×8MW(a)2×10MVA1G G1TG2G2T110KV 35KV2×8MW(b)20MVAG1G 2GG110KV2T2G(c)2×8MW2×10MVAG1G 1T G35KV精心整理 学习帮手TMY-100X8ZN21-10/1250配CD10ⅢLZZBJ-101000/5 0.5/10P 2×(ZR-YJV 22-6/3×240)RN2-6/0.5ASFWG8000-6/4950Ue=6.3kV Ie=916.45A COSφ=0.8LZX-10Q800/5 0.5/10PJ Y N 2-10-03(改)1G励磁变(厂家配套)励磁互感器(厂家配套)JDJ-6 36 0.1√3√J Y N 2-10-17J Y N 2-10-18RN2-6/0.5A 36 0.1 0.1JDZJ-63√√3J Y N 2-10-20√ 6 0.1 0.1√333JDZJ-6RN2-6/0.5AHY5WZ-10/302G同左ZN21-10/2500配CD10ⅢLFZJ-102000/5 0.5/0.5/10/10PJ Y N 2-10-03SF9-20000/110Y,d11121±3×2.5%/6.3kV U k %=10.5%LGJ-120GW4-110DW/630左接地LW25-1261250A,40kA GW4-110DW/630双接地LCWB 6-110100/50.2/0.5/10P/10PTYD-110/ -0.07H 3√LRD-60-B 50/5GW4-110DW/630双接地JDCF-110Y5W1-100/260√110 0.1 0.13√√33GW 13-60G/400Y1W-73/15ZN21-10/630配CD10ⅢLZZBJ-10100/5 0.5/10PJ Y N 2-10-03ZR-YJV 22-6/3×50SC9-800/6.3D,yn116.3±5%/0.4kV Ud%=7LMZ1-0.5 1200/5LMZ1-0.5 1200/5SC9-800/10D,yn1110±5%/0.4kV Ud%=7ZR-YJV 22-10/3×50LZZBJ-10100/5 0.5/10PZN21-10/630配CD10ⅢJ Y N 2-10-06(改)ZR-YJV 22-10/3×5010kV外来电源J Y N 2-10-19JDZJ-10HY5WZ-17/51RN2-10/0.5A10/0.1kV0.4kVLMY100×8-40×8DW15-1200DW15-1200DW15-12000.1LMY100×8-40×8G~G~TMY-100X8GW4-110DW/630左接地图5-19 某水电站电气主接线全图精心整理学习帮手精心整理 学习帮手图5-20 地区变电所接线8回35kV220kV4 回2×120MVA至无功补偿装置6 回2×60MVA4回2×10MVA1T图5-21 终端变电所接线4回10kV2T110kV 35kV第六章图形精心整理学习帮手精心整理学习帮手精心整理学习帮手精心整理 学习帮手VV22-13×50+1×251#厂变进线V 42L6-A,0~150A DT864-2,380/220V,3(6A)42L6-V,0~450V说明:BT95O9为事故照明切换板,其直流电源用VV22-1-2×4电缆引至直流屏。

变电站主接线图非常好

变电站主接线图非常好

变电站主接线图非常好变电站主接线图是一种重要的电气图形,描述了变电站中各种电气设备之间的连接方式。

这张图是变电站的基础且必需的图纸之一,它也是所有变电站设备调试和维护的基础。

一、什么是变电站主接线图?变电站主接线图又被称为总图或一次接线图。

它描述了中压电气设备和高压电气设备之间的连接和配电系统的结构。

变电站主接线图被广泛用于设计变电站、调试设备和记录现有设备。

变电站主接线图主要包括高压侧主接线图、中压侧主接线图、低压侧主接线图、系统接地图等内容。

这些内容都形成了变电站主接线图的完整结构,确保变电站的正常运行。

二、变电站主接线图的作用变电站主接线图是变电站的核心图纸之一,主要是为了:1. 保障设备安全运行通过变电站主接线图,我们可以了解到变电站设备之间的电气联系,并从中得到相应的电气参数。

这些参数对于保障设备的安全运行至关重要。

我们可以利用主接线图来识别设备问题,解决电气设备的故障和维修。

2. 提高变电站可靠性变电站主接线图能帮助我们了解电源侧和负载侧的配电系统结构,从而更好地规划电网的运行。

在变电站运行中,主接线图也能够发挥很大作用:变电站在发生故障时,我们可以通过主接线图来正确地找到故障原因,同时准确地断电,保证变电站和附近社区的安全。

3. 便于修改和更新由于变电站主接线图与变电站的实际运行有关,所以它的修改和更新非常重要。

通过主接线图,我们可以更好地进行变电站的规划和更新,避免设备更换后连接错误等问题,提高变电站主要设备的可靠性,而主接线图也可以帮助我们更好地更新变电站技术。

三、怎样编制变电站主接线图?变电站主接线图的编制涉及到许多专业知识,也与变电站的实际情况有关。

下面我们简单介绍一下编制变电站主接线图的主要步骤。

1. 收集资料和信息在编制主接线图之前,我们需要收集一些变电站的基本信息和电气资料。

首先是变电站的排列图,这一步是其中的一个重要环节,需要对变电站进行准确的绘图和测绘。

其次是收集各项高、中、低压电网的电气参数,如电压、电流及各种故障状况等。

变电站主接线图(解释)

变电站主接线图(解释)

变电站主接线图(解释)变电站⼀次系统图1、单母线接线特点:只有⼀组母线,所有电源回路和出线回路,均经过必要的开关电器连接到该母线上并列运⾏。

主要优点:接线简单、清晰,所⽤电⽓设备少,操作⽅便,配电装置造价便宜。

主要缺点:适应性差,母线故障或检修,全部回路均需停电;任⼀回路断路器检修,该回路停电。

适⽤范围:单电源的发电⼚和变电所,且出线回路数少,⽤户对供电可靠性要求不⾼的场合;10kV纯⽆功补偿设备出线(电容器、电抗器)。

2、单母线分段接线特点:与单母线接线⽅法相⽐,增加了分段断路器,将母线适当分段。

当对可靠性要求不⾼时,也可利⽤分段隔离开关进⾏分段。

母线分段的数⽬,决定于电源的数⽬,容量、出线回数,运⾏要求等。

母线分段⼀般分为2-3段。

优点:母线发⽣故障时,仅故障母线段停电,缩⼩停电范围;对重要⽤户由两侧共同供电,提⾼供电可靠性;缺点:当⼀段母线故障或检修时,与该段所连的所有电源和出线均需断开,单回供电⽤户要停电;任⼀出线断路器检修,该回路要停电。

适⽤:6~10kV,出线6回以上;35~66kV,出线不超过8回时;110~220kV,出线不超过4回时。

3、单母线分段带旁路母线接线优点:增设旁路母线,增设各出线回路中相应的旁路隔离开关,解决出线断路器检修时的停电问题。

为了节省投资,可不专设旁路断路器,⽽⽤母线分段断路器兼作旁路断路器。

因为电压越⾼,断路器检修所需的时间越长,停电损失越⼤,因此旁路母线多⽤于35kV以上接线。

适⽤:6~10kV接线⼀般不设旁路母线;35~66kV,可设不专设旁路断路器的旁路母线;110kV出线6回以上,220 kV出线4回以上,宜⽤专设旁路断路器的旁路母线;出线断路器使⽤可靠性较⾼的SF6断路器时,可不设旁路母线。

4、双母线接线优点:两条母线互为备⽤,⼀条母线检修时,另⼀条母线可以继续⼯作,不会中断对⽤户的供电;任⼀母线侧隔离开关检修时,只需断开这⼀回路即可;⼯作母线故障时,所有回路能迅速切换⾄备⽤母线⽽恢复供电;可将个别回路单独接在备⽤母线上进⾏特殊⼯作或试验;因⽽可靠性⾼,运⾏⽅式灵活,便于扩建。

某地区小型220KV变电站一次主接线图

某地区小型220KV变电站一次主接线图
220kV变电站新建施工图电气主接线图2#郇阳III备用(郭村)备用(楚侯)北郊备用(万荣)备用北相城北主变LF21Y-D110/100110kV备用(家具城)III桃园ABC备用运城LGJ-400/355P30/5P30/5P20/5P20/0.2/0.2S三家庄LF21Y-D150/136CABBCA三家庄BCAACB220kVC备用BA5P20/5P20/5P20600,1200/5ALJW1-10W,400/5AGW13-110W,630A5P20GW13-63W,630ALJW1-10W,400/5A5P20YN,Yno,d11Uk1-2=14%Uk2-3=8%Uk1-3=24%SFPSZ9-150000/220220%%P8X1.25%/115/36.75kV150/150/150MVA1#主变参数LRB-110,3只5P20/5P20/5P20600,1200/5A5P20/5P20200~600/5ALRB-63,2只LRB-110,2只200~600/5A5P20/5P20同下桃同园同桃园桃园桃园同同桃园桃同园同(工业园区)GW4-126IIDW2X600/5A2LGJ-300/25GW4-126IIDWGW4-126W2LGJ-300/252X600/5A/0.2/0.2S5P40/5P40/5P40LGJ-300/50GW4-126IIDW2X600/5ALB7-110W35P40/5P40/5P400.2/0.2SGW4-126WLW25-126WGW4-126IIDW郇阳同上同XGN-35Z-08G(2000A,31.5kA)XGN-35-42(2000,31.5)电容器3组(21-23)站用变SC9-500 Ud=6%备用备用备用备用北相RW1-35 15AY10W-51/134备用站用变35%%P5%/0.4-0.23KV1250A 31.5kAGN27-35LH-120JN-35/0.2SLMY-100X1035kVIIGN27-35 XGN-35-49G(2000A.31.5)0.1/3kV35/3, 0.1/3,LXQ-35RN2-35.0.5AHY5WZ-51/134XGN-35(Z)-20G/2000-31.51250A 31.5kA2000A 31.5kAZN12-40.5300/510P20/0.2GN27-35 GN27-35ZN12-35W10P20/10P20LZZB7-35Q10P20/0.2GN27-3510P20/LMY-100X1035kVIS9-500 Ud=6%备用BCA备用备用说明: 220KV 远景进出线6回,本期4回 本期1回 35KV无功补偿按每台主变3组考虑 110KV 远景进出线12回,本期4回 35KV 远景进出线6回,实线为本期所上。GW16-252W3AP1 FI-245kV5P20/5P20/5P30/5P30/LB7-220W30.2/0.2S2X600/5A2LGJ-300/25GW17-252DWTYD220/ 3-(A相)0.005H2500A 125kA3150A 50kA5P30/5P30/0.2/0.2SGW17-252DWGW16-252W5P20/5P20/LB7-220W32X600/5A2LGJ-300/251250A 100kA2000A 40kA1250A 100kA1250A 100kA2000A 40kA2000A 40kA1250A 100kA1250A 100kA1250A 100kATYD110-0.02H110/ 3,0.1/ 3,GW4-126IIDWY10W-100/260WLGJ-300/500.1/ 3,0.1KVLGJ-300/25Y10W-200/520W220/3/0.1/3/0.1/3/0.1KVGW16-252WTYD-220/ 3-0.01H3(YJV22-1KV-3x185+1x95)HY5WZ-51/1341250A 31.5kA10P20/0.2ZN-40.5 2000A 31.5kA1250A 31.5kAXGN-35Z(2000A,31.5kA)GN27-35400/5GN27-35JN-3536.75%%P5%/0.40-0.23KVFD21-2.4X2/44/√3-2WBAMH44/√3-3334-1WBAMH42/√3-3334-1WFD21-2.4X2/42/√3-2W10000(M)-3WTBB35-两组(CKK-200/35-6%)一组两组XGN-35Z-11G(2000A,31.5kA)HYW35-3-185E400/510P20/0.2JN-35YJV22-35-3X185HY5WR-51/134GW4-35DW/630两组/35-12%CKK-400ZN-40.5 GN27-351250A 31.5kA2000A 31.5kA2000A 31.5kA2000A 2000A TYD110/ 3-0.01H(A相)1250A 100kALZZB7-35QLZZB7-35Q(11-13)电容器3组LZZB7-35QLZZB7-35Q3150A 50kA2500A 125kA阳郇同阳郇同一组一组HYW35-3-185E备用LB7-110W32500A 125kAJW6-252IW630A3AP1 FI-245kV不接地,单接地2500A 125kAGW17-252DW2500A 125kALB7-220W33AP1 FI-245kVGW16-252W不接地,单接地2500A 125kA3150A 50kA2X300/5A5P40/5P40/5P40/0.2/0.2SLB7-110W3LW25-126WLW25-126WGW4-126IIDWGW4-126WGW4-126IIDWY10W-200/520WY10W-100/260WY5W-51/134WACBBCAACBBCAACBBCAACBBCAACBBCAACB日 期会 签 人 专 业 保护通信远动电二图 号工程设计阶段批 准审 核校 核设 计制 图日 期比 例版次编辑部:ivpinfo@本图纸由浩辰ICAD软件提供技术支持网易 电气 中国电气行业网络家园;因为专业,所以完美网易 NETEASE ==

变电站电气主接线ppt课件

变电站电气主接线ppt课件
电气主接线: 发电厂、变电站中生产、传输、分配电能的
电路,也称为一次接线。 电气主接线图:
用规定图形与文字符号将发电机、变压器、 母线、开关电器、输电线路等有关电气设备, 按电能流程顺序连接而成的电路图。
3
电力系统接线和输变电网络接线
电力系统接线
➢ 地理接线图:表明各发电厂、变电所的相对地理位 置和它们之间的联接关系
• 主接线标明一次设备的数量,作用,设备间的 连接方式,以及电力系统的连接情况。
• 电气主接线的方案,对电气设备选择,配电装 置的布置,运行的可靠性,灵活性,经济性, 维护检修的安全与方便等都有重大的影响,直 接关系到电力系统的安全、稳定、经济运行。
9
电气主接线基本类型
• 电气主接线一般按母线分类 • 常用形式分为: ➢有母线 ➢无母线
22
双母线分段接线
I
QF1
ⅡⅢ
QF3 L
电源1
QF2 电源2
➢ 特点
工作母线分成2段,即母线 II,III段,备用母线I不 分 段 , QF1 , QF2 为 母 联 , QF3为分段断路器。
正 常 工 作 时 , II , III 段 工 作,I段备用,在分段回 路中可接入分段电抗器L, 当任一分段故障时,L限 制相邻段供给的短路电流。
• 主要缺点:适应性差 母线故障或检修,全部回路均需停电 任一回路断路器检修,该回路停电
适用范围:单电源的发电厂和变电所,且出线回路数少,用户对供 电可靠性要求不高的场合
17
单母线分段接线图
WL1
WL2 WL3
WL4
~G
QF1
分段断路器
~G
18
单母线分段接线
• 与单母线接线方法相比,增加了分段断路器, 将母线适当分段。当对可靠性要求不高时,也 可利用分段隔离开关进行分段。
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档