SZL20-1.6-SW设计说明书
埃森平台 MW 系列微型电路保护器说明书
Protective Devices Miniature Circuit Breakers PLN4Catalog1.11EATON CORPORATION CA019074ENProtective DevicesMiniature Circuit Breakers PLN4 (MW)• T op-quality miniature circuit breakers 1P+N with a width of 1 module unit requiring little space for installation• Contact position indicator red - green • Guide for secure terminal connection • C omprehensive range of accessories can be mounted subsequently • Rated currents up to 40 A • Tripping characteristics B, C• R ated breaking capacity 4.5 kA according to IEC/EN 60898-1DescriptionSG157112EATON CORPORATION CA019074EN 3EATON CORPORATION CA019074ENSpecifications | Miniature Circuit Breakers PLN6, PLN4Description• High selectivity between MCB and back-up fuse due to low let-through energy • B usbar positioning optionally above or below • Compatible with standard busbar• Switching toggle in colour designating the rated current • M eets the requirements of insulation co-ordination, distance between con-tacts ³ 4 mm, for secure isolation • 1-pole breaking capacityI cn 1 = 3 kA Accessories:Auxiliary switch for subsequent installation ZP-IHK 286052ZP-WHK 286053Tripping signal switch for subsequent installation ZP-NHK 248437Remote control and automatic switching device Z-FW/LP 248296Shunt trip release ZP-ASA/..248438, 248439Undervoltage releaseZ-USA/..248288-248291Busbars:see capter busbar systemsTechnical DataPLN6, PLN4ElectricalDesign according toCurrent test marks as printed onto the device IEC/EN 60898-1Rated voltage U n 230 VAC Rated frequency50/60 Hz Rated breaking capacity according to IEC/EN 60898-1I cnPLN6 6 kA PLN4 4.5 kA Characteristic B, CBack-up fuse>6 kA max. 100 A gL/gG >4.5 kA max. 80 A gL/gG Selectivity class3Endurance electrical components ³ 8,000 switching operationsMechanical Frame size 45 mm Device height 80 mmDevice width 17.5 mm (1MU for 1+N)Mountingquick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protectionIP20Upper and lower terminals open-mouthed/lift terminalsTerminal protection finger and hand touch safe, DGUV VS3, EN 50274Terminal capacity1-16 mm 2Connection diagram1+N-poleDimensions (mm)Rated current I n (A)TypeDesignationArticle No.Units per package4.5 kA, Characteristic BSG157116PLN4-B6/1N 26317912/12010PLN4-B10/1N 26318012/12013PLN4-B13/1N 26318112/12016PLN4-B16/1N 26318212/12020PLN4-B20/1N 26318312/12025PLN4-B25/1N 26318412/12032PLN4-B32/1N 26318512/12040PLN4-B40/1N26318612/1201+N-pole4.5 kA, Characteristic CSG157116PLN4-C6/1N 26318912/12010PLN4-C10/1N 26319012/12013PLN4-C13/1N 26319112/12016PLN4-C16/1N 26319212/12020PLN4-C20/1N 26319312/12025PLN4-C25/1N 26319412/12032PLN4-C32/1N 26319512/12040PLN4-C40/1N26319612/1201+N-pole Explanation PLN4:P = xPole , LN = Miniature Circuit Breakers 1P+N, 1MU , 4 = 4.5 kA4EATON CORPORATION CA019074EN5EATON CORPORATION CA019074ENShort-circuit Selectivity PLN4In case of short-circuit, there is selectivity between the miniature circuit breakers PLN4 and the upstream fuses up to the specified values of the selectivity limit current I s [kA] (i. e. in case of short-circuit currents I ks under I s only the MCB will trip, in case of short-circuit currents above this value both protective devices will respond).*) basically in accordance with EN 60898-1 D.5.2.bShort-circuit selectivity Characteristic B towards fuse link DII-DIV *)Short-circuit selectivity Characteristic C towards fuse link DII-DIV *)PLN4DII-DIV gL/gG I n [A]20253550638010060.7 1.2 2.9 4.52) 4.52) 4.52) 4.52)100.60.9 1.9 3.1 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.7 1.4 2.3 4.3 4.52) 4.52)200.50.7 1.4 2.2 4.0 4.52) 4.52)250.50.6 1.3 2.0 3.8 4.52) 4.52)320.50.6 1.2 1.8 3.4 4.52) 4.52)40<0.51)0.61.1 1.7 3.1 4.52) 4.52)Short-circuit selectivity Characteristic B towards fuse link D01-D03*)Short-circuit selectivity Characteristic C towards fuse link D01-D03*)PLN4DII-DIV gL/gG I n [A]2025355063801002 1.5 3.8 4.52) 4.52) 4.52) 4.52) 4.52)40.7 1.2 3.3 4.52) 4.52) 4.52) 4.52)60.7 1.1 2.6 4.52) 4.52) 4.52) 4.52)100.50.8 1.7 2.8 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.6 1.2 2.0 3.6 4.52) 4.52)200.50.61.2 1.8 3.3 4.52) 4.52)25<0.51)0.6 1.1 1.7 3.0 4.52) 4.52)32<0.51)0.6 1.0 1.6 2.8 4.52) 4.52)40<0.51)0.6 1.0 1.5 2.6 4.0 4.52)PLN4D01-D03 gL/gG I n [A]20253550638010060.60.9 2.5 4.52) 4.52) 4.52) 4.52)100.50.8 1.6 3.4 4.52) 4.52) 4.52)130.50.7 1.3 2.7 4.0 4.52) 4.52)160.50.6 1.3 2.5 3.8 4.52) 4.52)20<0.51)0.61.32.43.64.52) 4.52)25<0.51)0.6 1.2 2.3 3.3 4.52) 4.52)32<0.51)0.6 1.1 2.1 3.0 4.52) 4.52)40<0.51)0.6 1.0 2.0 2.8 4.52) 4.52)PLN4D01-D03 gL/gG I n [A]2025355063801002 1.1 2.0 4.52) 4.52) 4.52) 4.52) 4.52)40.60.9 2.7 4.52) 4.52) 4.52) 4.52)60.60.9 2.3 4.52) 4.52) 4.52) 4.52)100.50.7 1.5 3.0 4.52) 4.52) 4.52)130.50.71.32.7 4.0 4.52) 4.52)16<0.51)0.6 1.1 2.23.14.52) 4.52)20<0.51)0.6 1.1 2.1 2.9 4.52) 4.52)25<0.51)0.5 1.0 2.0 2.7 4.52) 4.52)32<0.51)0.5 1.0 1.9 2.6 4.52) 4.52)40<0.51)0.50.9 1.7 2.3 4.0 4.52)1) Selectivity limit current I sunder 0.5 kA2) S electivity limit current I s = rated breaking capacity I cn of the MCBShort-circuit selectivity Characteristic B towards fuse link NH-00*)Short-circuit selectivity Characteristic C towards fuse link NH-00*)PLN4NH-00 gL/gG I n [A]202532354050638010060.50.91.52.33.24.52) 4.52) 4.52) 4.52)10<0.51)0.7 1.2 1.5 2.0 3.1 3.9 4.52) 4.52)13<0.51)0.6 1.0 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.6 1.0 1.3 1.6 2.4 2.9 4.52) 4.52)20<0.51)0.50.9 1.3 1.5 2.3 2.8 4.3 4.52)25<0.51)0.50.9 1.1 1.4 2.1 2.6 4.0 4.52)32<0.51)0.50.8 1.0 1.3 1.9 2.4 3.6 4.52)40<0.51)0.50.80.9 1.1 1.7 2.2 3.3 4.52)PLN4NH-00 gL/gG I n [A]202532354050638010020.7 2.1 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)40.50.9 1.6 2.6 3.7 4.52) 4.52) 4.52) 4.52)60.50.8 1.4 2.1 2.9 4.52) 4.52) 4.52) 4.52)10<0.51)0.6 1.0 1.4 1.9 2.8 3.5 4.52) 4.52)13<0.51)0.60.9 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.50.7 1.0 1.3 2.0 2.5 3.8 4.52)20<0.51)0.50.70.9 1.2 1.8 2.3 3.5 4.52)25<0.51)0.50.70.9 1.1 1.6 2.1 3.3 4.52)32<0.51)<0.51)0.60.8 1.1 1.5 2.0 3.1 4.52)40<0.51)<0.51)0.60.8 1.0 1.4 1.9 2.9 4.52)Load Capacity PLN4Let-through Energy PLN4Determined according to 60898-1.Maximum let-through energy PLN4, Characteristic BMaximum let-through energy PLN4, Characteristic CLoad capacity in case of MCB block installationCurrent carrying capacity at ambient temperature (I n = 2-13 A)Permitted permanent load at ambient temperature T (°C) with n devices: I DL = I n K T (T)K N (N).Current carrying capacity at ambient temperature (I n = 16-25 A)Current carrying capacity at ambient temperature (I n = 32, 40 A)Number of devices (n)L o a d c a p a c i t y f a c t o r K N500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A 2 s e c ]Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A2 s e c ]EatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton.eu© 2020 EatonAll Rights Reserved Printed in AustriaPublication No. CA019074EN Article number 302799-MK July 2023Grafics: SRA, Schrems9010238178694Eaton Industries (Austria) GmbH Scheydgasse 421210 Vienna AustriaFollow us on social media to get the latest product and support information.Eaton is a registered trademark.All other trademarks are property of their respective owners.To contact us please visit https:///contacts For technical questions please contact your local Eaton team.Changes to the products, to the information contained in thisdocument, and to prices are reserved; as are errors and omissions.Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to trademarks (especially Eaton, Moeller,and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.Eaton is an intelligent power management company dedicated toimproving the quality of life and protecting the environment for people everywhere. We are guided by our commitment to do business right, to operate sustainably and to help our customers manage power - today and well into the future. By capitalizing on the global growth trends of electrification and digitalization, we’re accelerating the planet’s transition to renewable energy, helping to solve the world’s most urgent power management challenges, and doing what’s best for our stakeholders and all of society.For more information, visit .。
20 cu ft WELDED STEEL ATV CART 3460SD-ATV 产品说明书
3460SD-ATV20 cu ft WELDED STEEL ATV CART1 (x1)3 (x1)4 (x1)6 (x2)19 (x1)5 (x2)16 (x4)17 (x2)9 (x2)8 (x1)18 (x2)14 (x2)15 (x2)10 (x8)11 (x14)12 (x1)13 (x3)2 (x1)7 (x1)38 (x4)37 (x1)TOOLS REQUIRED FOR ASSEMBLY:9/16" Wrench and Socket•Needle-Nose Pliers •Grease Gun•Carton Contents121011311373812413Attach undercarriage to body securely with hardware as shown.Attach front support to body securely with hardware as shown.Align holes in swivel clevis and undercarriage and install pin as shown.Secure pin on both ends with hairpins.132514151661617Press down on drawbar until it locks into place.Insert stub axles into undercarriage and secure with pins as shown.Slide washers and wheels onto stub axles as shown and install cotter pins. Bend legs of cotter pin to secure.46571181891913Attach tailgate to body as shown. No hardware is required, tailgate should move freely up or down.Attach ball hitch to drawbar with spacers and hardware as shown.Install hitch pin and hairpin to secure High Speed Safety Clevis.798Periodic Maintenance:Tighten fasteners as needed before each use •Check tire pressure before each use•Grease wheels annually (high temp red lithium grease recommended)•Before Using Dump Cart:Apply lithium grease to wheels using grease gun until grease can be seen 1.squeezing out from both sides of the wheel.Check tire pressure and inflate to 24 psi if needed.2.Read all Safety Rules found on page 1.3.How to Use Dump Cart:Attach Dump Cart to your ATV or UTV.1.Do not exceed 1500 pounds when loading material into the cart body.2.Distribute the weight of the load as evenly as possible in the cart body for3.best handling.When hauling heavy loads, verify that your vehicle has adequate towing and 4.braking capacity.Do not exceed 20 miles per hour when towing Dump Cart.5.Do not exceed 5 miles per hour without securing High Speed Safety Clevis.6.How to Empty Dump Cart:Step down the foot pedal to release the latch mechanism.1.Swivel as desired to guide the material to preferred location.2.Lower the body and guide the latch into the drawbar and relatch.3.WarrantyIf this product fails due to a defect in material or workmanship within THREE YEARS from the date of purchase, we will at our option repair or replace it free of charge. This warranty excludes tires and wheels, which are expendable and become worn during normal use.This warranty does not cover:•Repairs necessary because of operator abuse or negligence.Equipment used for commercial or rental purposes.•Paint that is worn or faded due to normal use or exposure.•To arrange for product repair call 1-800-652-2321, or return this product to place of purchase for replacement.This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. This warranty applies only while this product is in use in the United States.In the space below record the purchase date of your Dump Cart.Model Number 3460SD-ATVPurchase DateKeep this Owner's Manual and your receipt in a safe place for future reference.After the three year warranty period all replacement parts may be ordered by calling 1-800-652-2321.When ordering replacement parts, always give the following information:•Product 20 cu ft WELDED STEEL ATV CART•Model Number 3460SD-ATV•Part Number•Part Description1236161911131416155177111020291331122832212225242330272623229818114363738333435ITEM PART NO DESCRIPTION QTY ITEM PART NO DESCRIPTION QTY 16004183BODY, WELDED 34601206000369SHOULDER BOLT, 1/2" X 3/8"1 26004193UNDERCARRIAGE1213000720WASHER, 3/8" USS1 36004221FRONT SUPPORT122300061HEX NUT, 3/8-16 C-LOCK4 46004216DRAWBAR ASSEMBLY (incl. 20-32)1236000324BEARING2 56000523AXLE, STUB2246000370HEX BOLT, 3/8-16 X 3-1/2"2 66000727WHEEL, 18/950-8 X 1" (BLACK)225300055HEX BOLT, 3/8-16 X 3"1 7401042TAILGATE1266000305FOOT PEDAL1 8308301COUPLER, 1-7/8" BALL1276000309LATCH1 96004202SPACER, BALL HITCH228300075WASHER, 1/2" USS1 106001285HEX BOLT 3/8"-16 X 2-1/2"8296000368WASHER, SPRING1 11310061HEX NUT, 3/8-16 NYLOC14306000325SPRING, LATCH2 126000371PIN, 1/2" X 2-13/32"1316000321CLEVIS, SWIVEL1 136000372HAIRPIN COTTER, 0.080" X 1-9/16"3326004220DRAWBAR1 143000811CLEVIS PIN, 1/4" X 1-1/2"2336004215OWNER'S MANUAL1 153000812HAIRPIN COTTER, 0.080" X 1-3/16"2346004227HARDWARE BOLT BAG1 16300076WASHER, 1" SAE4356000162DECAL, OSI PRO2 17300087COTTER PIN, 3/16" X 1-1/2"2366000818KIT, 1" WHEEL BEARINGS1 186004260HEX BOLT, 3/8-16 X 4"2376004245ADAPTER PLATE1 196000533PIN, HITCH1386004259CARRIAGE BOLT, 3/8-16 X 1"4EXPLODED VIEWBefore you call…Please email our customer service team at **************** with:1. A description of the issue you are having2. Photos of the issue that include an overall view and detailed view from multiple angles3. If applicable, a short video showing the issueIf you believe this is a warranty related issue please see the warranty page in this manualReplacement Parts:If you are ordering replacement part(s) for your product, please note that some parts are only available as a repair kit.1. First locate the part on the Exploded View page (page 8)2. Take note of the part number3. If the part number is on the Repair Kits page, use the kit number to order your replacement parts4. If the part number is not on the Repair Kits page, use the part number to order your replacement part You can place your parts order online at /partsstore You can also reach our Customer Service Department at 1-800-652-2321KITKIT NUMBERPART NUMBER PART DESCRIPTIONQTY HARDWARE BOLT BAG60042276004259CARRIAGE BOLT, 3/8-16 X 1"46004202SPACER, BALL HITCH26001285HEX BOLT 3/8"-16 X 2-1/2"8310061HEX NUT, 3/8-16 NYLOC 146000371PIN, 1/2" X 2-13/32"16000372HAIRPIN COTTER, 0.080" X 1-9/16"33000811CLEVIS PIN, 1/4" X 1-1/2"23000812HAIRPIN COTTER, 0.080" X 1-3/16"2300076WASHER, 1" SAE4300087COTTER PIN, 3/16" X 1-1/2"26004260HEX BOLT, 3/8-16 X 4"26000533PIN, HITCH11" WHEEL BEARING KIT600081860008141" BEARING RETAINER 460008161" ROLLER BEARING 2DRAWBAR ASSEMBLY6004216300055HEX BOLT, 3/8-16 X 3"1300061HEX NUT, 3/8-16 C-LOCK 4300075WASHER, 1/2" USS 13000720WASHER, 3/8" USS 16000305FOOT PEDAL 16000309LATCH16000321CLEVIS, SWIVEL 16000324BEARING26000325SPRING, LATCH 26000368WASHER, SPRING16000369SHOULDER BOLT, 1/2" X 3/8"16000370HEX BOLT, 3/8-16 X 3-1/2"26004220WELDED DRAWBAR 1REPAIR KITSNotes10 (800)652-2321Designed And Tested In Columbus, OhioMODEL # 3460SD-ATV2575 Ferris Road Columbus, OH 43224(800)652-2321Manufactured In The U.S.A. From DomesticAnd Imported Components。
美国爱森(Eaton)Moeller系列EASY易控制传感器控制继电器数据手册说明书
Eaton 197509Eaton Moeller® series EASY easyE4 control relay, basic unit (expandable, Ethernet), 100–240 VAC, 100–240 VDC (cULus: 100–110 VDC), digital inputs: 8, digital outputs: 4 relay, push-inSpécifications généralesEaton Moeller® series EASY Control relay197509401508194087558 mm 90 mm 72 mm 0.25 kg IEC/EN 61000-4-2 IEC 60068-2-27 IEC/EN 61000-4 EN 55011 EN 55022 IEC 60068-2-6 UL ListedUL Category Control No.: NRAQ, NRAQ7 IEC/EN 61131-2 IEC 60068-2-30 EN 61010 IEC/EN 61000-6-3 IEC/EN 61000-6-2 EN 50178UL File No.: E205091 DNV GL CEAccuracy of the real-time clock depending on ambient air temperature - fluctuations of up to ± 5 s/day (± 0.5 h ⁄year) are possibleEASY-E4-AC-12RCX1P Product NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog NotesModel CodeExpandable Networkable (Ethernet)Relay outputTimerReal time clock IP2050/60 Hz (Digital inputs, at 115/230 V AC)50/60 Hz (Digital inputs, at 24 V DC)According to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-20125,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)25,000 Operations (Filament bulb load at 500 W, 115/120 V AC) 25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)1,000,000 OperationsTop-hat rail fixing (according to IEC/EN 60715, 35 mm)Screw fixing using fixing brackets ZB4-101-GF1 (accessories) Front build in possibleRail mounting possibleIII2Control relays easyE4MODBUSTCP/IP6 kV (contact-coil)5 % (transistor outputs)≤ 5 %Features Fitted with:Degree of protectionInput frequencyInsulation resistanceLifespan, electricalLifespan, mechanicalMounting methodOvervoltage categoryPollution degreeProduct categoryProtocolRated impulse withstand voltage (Uimp) Residual rippleEASYSOFT-SWLIC/easySoft70.5 Hz, Inductive load, Relay outputs 10 Hz, Relay outputs2 Hz, Resistive load/lamp load, Relay outputs easyE4 base device easyE4B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC AC50 mm Drop height, Drop to IEC/EN 60068-2-310.3 mHorizontal Vertical15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts According to IEC/EN 60068-2-6 10 - 57 Hz, 0.15 mm constant amplitude 57 - 150 Hz, 2 g constant acceleration795 - 1080 hPa (operation)-25 °C55 °C-40 °C70 °CClearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 Condensation: prevent with appropriate measures 5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)ResolutionSoftwareSwitching frequencyTypeUsed with Utilization categoryVoltage type Drop and toppleHeight of fall (IEC/EN 60068-2-32) - max Mounting position Shock resistanceVibration resistanceAir pressureAmbient operating temperature - min Ambient operating temperature - max Ambient storage temperature - min Ambient storage temperature - max Environmental conditionsRelative humidityAir dischargeTerminal capacity1 min (Range H:M)1 s (Range M:S)5 ms (Range S)8 kV2 kV, Signal cable2 kV, Supply cableAccording to IEC/EN 61000-4-46 kV1 V/m at2 - 2.7 GHz (according to IEC EN 61000-4-3)10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)10 V (according to IEC/EN 61000-4-6)Class B (EN 61000-6-3)1 kV, Supply cables, symmetrical, power pulses (Surge), EMC2 kV, Supply cables, asymmetrical, power pulses (Surge), EMC According to IEC/EN 61000-4-5 Level 410 ms 0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule0.2 - 4 mm² (AWG 22 - 12), solid8 A4 W10 W200000 Operations at DC-13, 24 V DC, 1 A (500 Ops./h) 300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)240 VMax. 300 V ACMax. 300 V DC85 - 264 V AC100/110/115/120/230/240 AC (-15 %/+10 %)50/60 Hz (± 5%)85 VAC264 VAC85 VDC264 VDC1 A DC, at R 300 (UL/CSA)10 A AC, at 240 V AC (UL/CSA)8 A DC, at 24 V DC (UL/CSA)5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)Burst impulseContact dischargeElectromagnetic fieldsImmunity to line-conducted interference Radio interference classSurge ratingVoltage dips Conventional thermal current ith of auxiliary contacts (1-pole, open)Power consumptionPower lossRated breaking capacityRated insulation voltage (Ui)Rated operational voltageSupply frequencySupply voltage at AC, 50 Hz - minSupply voltage at AC, 50 Hz - maxSupply voltage at DC - minSupply voltage at DC - maxUninterrupted current≥ 1A (T), Fuse, Power supply Ethernet: RJ45 plug, 8-polePush in terminals10/100 MBit/sStatus indication of Power/RUNStatus indication of Ethernet: LED100 m (max. permissible per input I7 to I8), Digital inputs115/230 V AC40 m (max. permissible per input I1 to I6), Digital inputs 115/230 V ACCAT5± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year)± 1 %, Repetition accuracy of timing relays (of values)21 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 0 to 1, Debounce OFF21 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 1 to 0, Debounce OFF16⅔ ms, Digital inputs 115/230 V AC 60 Hz (I7, I8), Delay time from 1 to 0, Debounce OFF0.03 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF0.03 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF20 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 0 to 1, Debounce ON20 ms, Digital inputs 115/230 V AC 50 Hz (I7, I8), Delay time from 1 to 0, Debounce OFF20 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON2 x 6 mA (I7 - I8, at 230 V AC, 50 Hz, at signal 1)2 x 4 mA (I7 - I8, at 115 V AC, 60 Hz, at signal 1)6 x 0.25 mA (I1 - I8, at 115 V AC, 60 Hz, at signal 1)Condition 1: 79 - 264 V AC, Digital inputs, 115/230 V AC) Condition 0: 0 - 40 V AC, Digital inputs, 115/230 V AC)28/28 VA (DC, at R 300)3600/360 VA (AC, at B 300)Short-circuit protection Connection typeData transfer rateLED indicatorCable length Cable type AccuracyDelay timeInput currentInput voltageMaking/breaking capacity84VoltageRelay outputs in groups of 1> 500 mA (Relay outputs, Recommended for load: 12 V AC/DC) Current4 Relay OutputsNot permitted NoneBasic isolation: 600 V AC (Relay outputs)Between Analog inputs and Digital inputs: noBetween Relay outputs: yesBetween Digital inputs 115/230 V AC and Interface: yes Between Digital inputs 115/230 V AC and Memory card: noYesNone300 V AC, Between coil and contact, According to EN 50178 300 V AC, Between two contacts, According to EN 501784 W0 W0 W4 WMeets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements.eaton-electrical-timers-easy-control-relays-characteristic-curve-002.epsDA-DC-00004703.pdfDA-DC-00004708.pdfDA-CE-ETN.EASY-E4-AC-12RCX1PDA-MN-h1430deMN050009_FRMZ049014ENmz049001en.pdfVideo easy E4 control relayIL050020ZUDA-CD-uc_12rcx1DA-CS-uc_12rcx1Number of inputs (analog)Number of inputs (digital) Number of outputs (analog) Number of outputs (digital) OutputParallel switching Explosion safety category for gas Potential isolationProtection against polarity reversal Explosion safety category for dust Safe isolationEquipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidStatic heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation Characteristic curve Declarations of conformity eCAD modelGuide utilisateurInstallation videos Instructions d'installation mCAD modelDoes not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility.Is the panel builder's responsibility.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.eaton-logic-relays-easy-control-relays-dimensions.eps 2723DIM-100eaton-modular-plc-easy-control-relays-3d-drawing-002.eps10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical functionSchémasEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Tous droits réservés. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
泰而勒 C708 和 C716 型 热处理 软冰机 用户手册说明书
C708 和 C716 型
热处理 软冰机
原始操作说明 059061CH
2005年1月(初版) (2013年12月23日更新)
当需要维修服务时,请填写本页以供快速参考:
泰而勒公司经销商: 地址: 电话: 服务: 零件: 安装日期:
数据标签上的信息:
型号:
序号:
电力规格:
电压
相
保险丝最大额定值:
© 2005 Taylor Company(初版) (2013 年 12 月更新)
保留一切权利 059061CH
任何人如对本手册的任何部分进行任何未经授权的复制、透露或分发,均可能违反美国和其他国家的版权法,其 侵权行为可能导致最高达 250,000 美元(根据 17 USC 504)的法定赔偿,并可能导致进一步的民事和刑事惩 罚。保留一切权利。
49
细菌数量的排疑解难
49
常规维护检查
49
冬季贮存
0
第八部分
故障排除指南
51
第九部分
零件修
56
第十一部分 零件的有限保修
58
注:持续研究能够不断提高质量。因此,本手册所含信息可能会有变动,对此恕不事先通知。
注:只有工厂或其授权翻译代表提供的说明才可以被认为是正版说明。
请遵守您当地的电气规程!
每台机器的每个数据标签需要有一个专用电源,请查 看机器数据标签上关于分支电路过电流保护或保险 丝、载流容量和其它电力规格指标。关于正确的电源 联接,请参考在配电盒内提供的接线图。
当心:本机器必须正确接地!否则会导致触 电而造成严重人身伤害!
本机器具有等电位接地接线片,它必须由授权安 装工正确地安装在机架的背后。可移动面板和设备框 架上的等电位联结符号(IEC 60417-1 的 5021)标 明了安装位置。
新亚 PLC2.0-FSL20 单机双级螺杆并联控制器 用户手册说明书
PLC2.0-FSL20 单机双级螺杆并联控制器 适用于复盛单机双级系列螺杆压缩机苏州新亚科技有限公司PLC2.0-FSL20复盛单机双级螺杆并联机组控制器用户手册主要功能及技术指标主要功能如下:☞压力显示和控制:使用系统低压压力控制整个机组。
☞启动方式:星三角转换启动。
☞内置能量控制:四段容调控制,25%、50%、100%,实现螺杆机组的加卸载。
☞冷凝风机控制:使用系统高压压力控制,将冷凝风机控制在设定的压力范围之内。
☞高低压力告警:高压压力过高和低压压力过高及过低告警。
☞油路循环控制:油冷却控制、油压控制及油温控制。
☞回油阀控制:通过压缩机运行开启回油电磁阀。
☞液喷射控制:根据排气温度控制,当排气温度过高则开启喷液电磁阀。
☞经济器控制:根据吸气压力开启经济器,适度使之过冷,提升制冷量。
☞外部告警功能:外部开关量告警信号输入,四种告警模式可设。
☞并联从机接口:通过外部串口通讯连接从机,可实现五并联机组的联动运行。
☞相序告警:三相电相序错误告警。
☞2路RS485接口:用于远程监控及上位机触摸屏操作。
主要技术指标:压力显示范围:低压:-0.8 - 7.0 bar 高压:0.0 - 30.0 bar 精度1%压力设定范围:低压:-0.8 - 7.0 bar 高压:0.0 - 30.0 bar 精度1%压力传感器类型:电流型4~20mA 使用温度:-40 - 100℃温度显示范围:-50 - 150℃温度设定范围:-45 –145℃温度传感器类型:NTC R25=5kΩ,B(25/50)= 3470K电源电压:DC 24V/ 500mA使用环境:温度-15℃~ 50℃,湿度≤85%,无凝露海拔低于2000米,不适宜在含有酸、碱的场合使用禁止在易燃易爆环境下使用输出负载能力:8A/250VAC执行标准: Q/320585 XYK 01免责声明:请在使用前详细阅读本使用手册。
这将有利于对机组调试和使用取得最佳的性能及良好的运行状态。
电梯一体化控制器使用说明书
1.2 MORE5000 电梯一体化控制器标配功能说明 ................................................................7 1.3 MORE5000 电梯一体化控制器保护功能说明 ..............................................................11 第二章 产品信息...........................................................................................................................12 2.1、 命名规则及铭牌.........................................................................................................12
2.1.1、异步机、同步机用控制器命名规则: ...........................................................12 2.1.2、异步机、同步机用控制器铭牌命名规则: ...................................................12 2.1.3、机箱型号: ....................................................................................................... 12 2.1.4、MORE5000 系列电梯一体化控制器型号 ..........................................................13 2.1.5、技术规范 ........................................................................................................... 14 2.1.6、端子功能说明: ............................................................................................... 15 2.2、 主控板电气接线说明.................................................................................................15 2.2.1、主控板外观图 ................................................................................................... 16 2.2.2、主控板指示灯说明: ....................................................................................... 16 2.2.3、端口列表: ....................................................................................................... 16 2.2.4、插件 CN1 和 CN2 输入端子说明: ...................................................................17 2.2.5、插件 CN3 电源与输入端子说明: ...................................................................17 2.2.6、插件 CN4 输出端子说明:...............................................................................17 2.2.7、插件 CN6 接口端子说明:...............................................................................17 2.3、 编码器接线.................................................................................................................18 第三章 调试工具使用说明...........................................................................................................19 3.1、 MORE5000 电梯一体化控制器调试工具 ....................................................................19 3.1.1、手持操作器使用说明 ....................................................................................... 19 3.1.2、小键盘的功能及使用说明 ............................................................................... 24 第四章 功能参数表.......................................................................................................................26 4.1、 功能参数表说明.........................................................................................................26 4.2、 功能参数表的分组.....................................................................................................26 第五章 功能参数说明...................................................................................................................43 5.1、 F1 基本参数...............................................................................................................43 5.3、 F3 运行控制参数.......................................................................................................45 5.4、 F4 楼层调整参数.......................................................................................................48 5.5、 F5 门功能参数...........................................................................................................48 5.6、 F6 端子定义参数.......................................................................................................49 5.6.1、X1—X24 输入端子功能选择............................................................................49 5.6.2、高压检测定义 ................................................................................................... 51 5.6.3、Y1—Y6 输出端子功能选择..............................................................................51 5.6.4、轿顶板输入/出或二合一门机输入/出功能定义 ...........................................52
松科手持式激光焊接机用户手册(V3.0版)说明书
SKL20版本松科手持式激光焊接机用户手册请您在使用该系统之前请务必阅读该手册⌝本手册内容是双摆手持激光焊接系统用户手册⌝先仔细阅读该手册,保证正确电气连接SKL-V3.0手持激光焊接机用户使用手册(暂定版)V3.0版本+双摆焊接头福建松科机器人有限公司地址:中国(福建)自由贸易试验区厦门片区港中路1283 号2 号楼2 单元二层电话:189-****3999,************网址:版权声明:福建松科机器人有限公司(以下简称松科公司)保留所有权力。
松科公司保留在不事先通知的情况下,修改本手册中的产品和产品规格等文件的权力, 同时保留对本产品附带的任何文档进行修改的权力。
使用者在使用本文所述产品时请仔细阅读本手册,松科公司不承担由于使用本手册或本产品不当,所造成直接的、间接的、特殊的、附带的或相应产生的损失或责任。
松科公司不承担以下直接的或间接的责任或损失:⌝用户使用本手册或本产品不当⌝用户没有遵循相关的安全操作规程所造成的损失自然力造成的损失,使用中的机器有危险,使用者有责任在机器中设计有效的出错处理和安全保护机制,松科公司没有义务或责任对由此造成的附带的或相应产生的损失负责。
产品广泛应用于电池、汽车、汽车配件、电子电路、光纤通讯器件、手机、家用电器、厨卫五金、精密器械、仪器仪表、金银首饰、医疗器件、太阳能、眼镜行业、马达行业等。
产品深受各行各业的肯定与赞扬,在客户中有着良好的口碑和信誉。
●支持工艺库存储;●6 种出光模式(―、○、◎、⊙、△、8);●光斑可调(0-5)mm;●控制屏直接数字化设置送丝机参数;●支持送(0.8、1.0、1.2、1.6)不锈钢、碳钢、铝焊丝;●邀请专业国际激光友人翻译,同时获有中、英、韩、日、俄、繁、法、西班牙、以色列九国语言;●系统时时监控运行状态,对激光器、冷水机、控制板运行监控并收集运行状态;●完美取代部分传统氩弧焊、电焊在薄板不锈钢板、铁板、铝板等金属材料方面焊接;●重量轻、体积小、人体工学设计握感舒适;●安全锁触碰出光;●操作简易上手,对操作人员要求极低;●抗干扰强;●全密封结构内置水路、风路;●配置自主研发控制系统;●焊缝美观,速度快、无焊痕,无变色,无需后期打磨使用激光焊接系统注意事项1. 双摆工业焊接头包含了激光器,水冷机,激光焊接系统,激光焊接头多个控制模块,为了避免被干扰,确保远离氩弧焊机二保焊机和干扰较大的相关设备,确保安全距离保持在5 米以上。
迅磊变频器说明书说课讲解
迅磊变频器说明书目录一、前言 Introduction1、购入时注意事项 Checks upon Delivery2、HC系列铭牌说明 Nameplate Description of HC Series Inverter二、安全使用注意事项Safety Precautions1、送电前Before the Power-up)2、运转中During the Operation三、产品标准规格Standards and Specifications1、产品个别规格Particular Specifications2、产品通用规格General Specifications四、储存及安装Storage and Installation1、储存Storage2、安装场所及环境Installation Site and Environment3、安装空间与方向Installation and Direction五、配线 Wiring1、主回路配线图Main Circuit Wiring Schematic Diagram2、接线端子说明Description of Terminal Block3、基本配线图Basic Connection Diagram4、配线注意事项Precautions on Wiring六、数位操作器说明Instruction of the Digital Operator1、数位操作器说明Description of the Digital Operator2、显示项目说明Description of Indicator Lamp Status3、操作说明Description of Operation Examples七、试运行Commissioning1、运行前检查Important Checks before the Commissioning2、试运行方式Commissioning Methods八、功能一览表Function List九、功能说明Descriptions of Functions十、保养维护、故障信息及排除方法Care & Maintenance, Fault Information and Troubleshooting1、保养检查注意事项Precautions about Inspection and Maintenance2、定期检查项目Periodical Inspection and Maintenance items3、故障信息及排除方法Fault Indication and Troubleshooting4、故障及分析Faults and Analysis十一、周边设施选用及配置Selection of Peripheral Devices and Disposition1、选件Options2、配置Disposition十二、附录Appendice1、简单应用举例Simple Examples of Application一、 前言承蒙您惠顾HC 系列多功能,高性能通用变频调速器。
WE20鳄鱼阀门规格与使用说明书
Series WE20 Butterfly ValveSpecifications - Installation and Operating InstructionsBulletin V-WE20The SERIES WE20 is offered in lug or wafer body styles and is equipped with a PTFE or EPDM liner. The most critical aspect of the Series WE20 Butterfly Valves is the cartridge seat design, which alleviates installation problems associated with common “dove tail design” seats. Valve torques are lower and more consistent as the seat dynamics are not dependent on being coupled between two flanges. Precision machining of the disc and body allow the cartridge design to maintain a tighter disc to seat tolerance, providing a perfect low torque seal each and every time the valve is cycled. The seat to disc seal is independent of flange support and capable of full rated dead end service.Actuators are directly mounted creating a compact assembly for tight spaces. Limit switches are able to be mounted directly to the valves allowing for remote position indication.The Series WE20 can be configured with either an electric or pneumatic actuator. Electric actuators are available in weatherproof or explosion-proof, a variety of supply voltages and two-position or modulating control. Two-position actuators use the supply voltage to drive the valve open or closed, while the modulating actuator accepts a 4 to 20 mA input for valve positioning. Actuators feature thermal overload protection and permanently lubricated gear train. The pneumatic double acting actuator uses an air supply to drive the valve open and closed. The actuator has two supply ports, with one driving the valve open and the other driving the valve closed. Spring return pneumatic actuators use the air supply to open the valve, and internally loaded springs return the valve to the closed position.The pneumatic double acting actuator uses an air supply to drive the valve open and closed. The actuator has two supply ports with one driving the valve open and the other driving the valve closed. Spring return pneumatic actuators use the air supply to open the valve and internally loaded springs return the valve to the closed position. Also available is the SV3 solenoid valve to electrically switch the air supply pressure between the air supply ports for opening and closing the valve. Actuators are constructed of anodized and epoxy coated aluminum for years of corrosion freeservice.WE20-CHD00-LEWE20-EDA06-LEWE20-CDA04-WP-AA07WE20-ETD04-LE-AWE20-CDA04-WP-NN08By DwyerVALVE DIMENSIONAL DRAWINGWAFER STYLE“WF”LUG STYLE“LT”AUTOMATED VALVE DRAWINGSWafer Valve withPneumatic ActuatorWafer Valve withElectric ActuatorWafer Valve withExplosion-Proof ActuatorLug Valve withPneumatic ActuatorLug Valve withElectric ActuatorLug Valve withExplosion-Proof ActuatorPNEUMATIC ACTUATORNote: For optimal operation, pneumatic actuators should be run with a supply of clean, lubricated air.Spring Return Actuator OperationAir to PORT 2 (the left hand port) causes the actuator to turn counterclockwise (CCW). Loss of air to PORT 2 causes air to exhaust and the actuator turns clockwise (CW). This is the FAIL CLOSE operation.Double Acting Actuators OperationAir to PORT 2 (the left hand port) causes the actuator to turn counterclockwise (CCW). Air to PORT 1 (the right hand port) causes the actuator to turn clockwise (CW).Pneumatic Actuator MaintenanceRoutine maintenance of pneumatic actuator:• Keep the air supply dry and clean• Keep the actuator surface clean and free from dust• Periodic checks should be done to make sure all fittings are tight• Pneumatic actuators are supplied with lubrication to last the entire life span of the actuator under normal operating conditions.The outer surface of the pneumatic actuator should be clean to avoid friction or corrosion. All fittings and connections should be tight to prevent leaks during operation. Check the bolts mounting the valve to the actuator to make sure they have not come loose during shipping or installation. Make sure the valve and actuator are not rubbing or jamming against other components during operation. The actuator should be inspected annually to make sure all fittings and bolts are tight and nothing has come loose during operation.Disassembling Pneumatic ActuatorsBefore beginning disassembly, ensure that the air supply to the actuator has been disconnected, all accessories have beenremoved, and that the actuator has been disassembled from the valve.1. Loosen the end cap fasteners (23) with a wrench (size varies depending on actuator model). On the spring return actuator, alternate 3 to 5 turns on each fastener until the springs are completely decompressed. Use caution when removing the cap since the springs are under load until the fasteners are fully extended.2. Remove the pinion snap ring (13) with a lock ring tool. The indicator (12) may now be removed.3. Turn the pinion shaft (2) counter clockwise until the pistons are at the full end of travel. Disengage the pistons (15) from the pinion. (Note: Low pressure air--3 to 5 psi MAXIMUM--might be required to force the pistons completely from the body.) Note the position of the pistons before removing them from the actuator body.4. Remove the pinion through the bottom of the actuator. The actuator is nowBe sure the actuator surfaces are free of debris and scratches before reassembling.1. Apply a light film of grease to all O-rings and the pinion before replacing.2. Put the pinion (2) back through the actuator with the flats of the pinion shaft running parallel with the body.3. When reassembling the actuator, make sure that the piston racks are square to the actuator body and returned to their original orientation. (Note: The normal operation of all spring return pneumatic actuators is FAIL CLOSED. To change the orientation to FAIL OPEN, rotate the racks 180º to create a reverse operation.4. When replacing springs in a spring return actuator, ensure that the springs are replaced in their identical position in the end cap from which they were removed. (Note: In some circumstances, you might want to change the standard 80 pound spring set to fit your application and available air pressure.5. Seal the end caps with a petroleum lubricant and bolt to actuator body.6. Check the seal of the actuator by covering seal areas (pinion, end caps) with soapy water and using low pressure air to the actuator to ensure that no bubbles are produced.Reassembling Pneumatic ActuatorsPneumatic Actuators Bill of MaterialsELECTRIC ACTUATORSElectric Installation1. Operate valve manually and place in the open position.2. Remove any mechanical stops the valve might have. (DO NOT REMOVE ANY PARTS NECESSARY FOR THE PROPER OPERATION OF THE VALVE, SUCH AS THE PACKING GLAND, PACKING NUT, ETC.)3. Ensure that the actuator output shaft and valve stem are aligned properly. If they are not, operate the valve manually until they are correct.4. Remove actuator cover.5. Bring power to the actuator. CAUTION: Make sure power is OFF at the main box.6. Wire the actuator per the diagram attached to the inside of the cover. Special actuators (those with positioner boards, etc.) will have diagrams enclosed inside the cover.7. Securely tighten bolts used to mount the actuator to a mounting bracket or directly to the valve mounting pad if it is ISO5211 compliant.8. Cycle the unit several times and check the open and closed positions of the valve. Cams are pre-adjusted at the factory; due to the variety of valve designs and types however, slight adjustments might be required.9. Replace cover and tighten screws.To Set The Open Position1. Cycle the valve to the open position by applying power to terminals. The top cam and switch control this position. In the open position, the set screw in the top cam will be accessible.2. If the valve is not open completely:A. Slightly loosen the set screw on the top cam.B. Rotate the cam clockwise (CW) by hand until the switch makes contact. Contact is made when a slight click can be heard. By making incremental CW movements of the top cam, the valve can be positioned precisely in the desired position.C. When the top cam is set, tighten the set screw securely.3. If the valve opens too far:A. Apply power to terminals. This will begin to rotate valve CW. When valve is fully open and in the exact position desired, remove power from actuator.B. Loosen the set screw in the top cam.C. Rotate the top cam counterclockwise (CCW) until the switch arm drops off the round portion of the cam onto the flat section. A slight click can be heardas the switch changes state.D. Continue applying power to terminals until valve is in the desired position.To Set The Closed Position1. Apply power to terminals to move the valve toward the closed position. The bottom cam and switch control the closed position. In the closed position, the set screw in the bottom cam will be accessible.2. If the valve is not closed completely:A. Slightly loosen the set screw on the bottom cam.B. Rotate the cam counterclockwise (CCW) by hand until the switch makes contact. Contact is made when a slight click can be heard. By making incremental CCW movements of the bottom cam, the valve can be positioned precisely in the desired position.C. When the top cam is set, tighten the set screw securely.3. If the valve closes too far:A. Apply power to terminals. This will begin to rotate valve CCW. When valve is fully closed and in the exact position desired, remove power from actuator.B. Loosen the set screw in the top cam.C. Rotate the top cam clockwise (CW) until the switch arm drops off the round portion of the cam onto the flat section. A slight click can be heard as the switch is no longer making contact with the round part of the cam.D. Continue applying power to terminals until valve is in the desired position.Electric Actuators Wiring Diagram: ACT-TH & ACT-MHWiring Diagrams forTH03-A to TH11-A: 110 VAC, TH03-B to TH11-B: 220 VAC, TH03-C to TH11-C: 24 VACHOTALVE ALVEWiring Diagrams for TH03-D to TH11-D: 24 VDCOPERATION:POWER TO 1 & 2 FOR CCW ROTATION POWER TO 3 & 4 FOR CW ROTATION TERMINALS 5 & 6 FOR FIELD LIGHT INDICATION CONNECTIONSW.#1 SW.#2SWITCH #1 OPEN SWITCH SWITCH #2 CLOSE SWITCHWiring Diagrams forMH03-A to MH11-A: 110 VAC, MH03-B to MH11-B: 220 VAC, MH03-C to MH11-C: 24 VACSW. 1, CLOSESW. 2, OPEN .SW. 3, CLOSE SW. 4, OPEN Wiring Diagrams forMH03-D to MH11-D: 24 VDCSW. 1, CLOSESW. 2, OPEN .SW. 3, CLOSE SW. 4, OPENElectric Actuators Wiring Diagram: ACT-TD & ACT-MDWiring Diagrams forTD02-A to TD07-A: 110 VAC, TD02-B to TD07-B: 220 VAC,TD02-C to TD07-C: 24 VACWiring Diagrams forTD02-D to TD07-D: 24 VDCWiring Diagrams forMD02-A to MD07-A: 110 VAC, MD02-B to MD07-B: 220 VAC,MD02-C to MD07-C: 24 VAC Note: To speed up installation of the control wires to the ACT-MDXX modulating actuator, it is recommended to remove the control module from the actuator. The control module can be removed by removing the two mounting screws on the left and right of the control module. Install the control wires to the correct terminal points and then reinstall the control module.Electric Actuator MaintenanceOnce the actuator has been properly installed, it requires no maintenance. The gear train has been lubricated and in most cases will never be opened.Duty Cycle Definition“Duty Cycle” means the starting frequency.Formula: Running Time ÷ (Running Time + Rest Time) x 100% = duty cycle–> Rest Time = Running Time x (1 - duty cycle) ÷ duty cycleFor example: The running time is 15 seconds30% duty cycle 15 x [(1 - 30%) / 30%] = 35 –> The rest time will be 35 seconds 75% duty cycle 15 x [(1 - 75%) / 75%] = 5 –> The rest time will be 5 seconds If the duty cycle is higher, the rest time will be shortened, which means the starting frequency will be higher.Thermal OverloadAll actuators are equipped with thermal overload protection to guard the motor against damage due to overheating.Mechanical OverloadAll actuators are designed to withstand stall conditions. It is not recommended to subject the unit to repeated stall conditions.Explosion-Proof Electric Actuators1. DO NOT under any circumstances remove the cover of theactuator while in a hazardous location. Removal of the cover while in a hazardous location could cause ignition of hazardous atmospheres.2. DO NOT under any circumstances use an explosion-proof electric actuator in a hazardous location that does not meet the specifications for which the actuator was designed.3. Always verify that all electrical circuits are de-energized before opening the actuator.4. Always mount and cycle test the actuator on thevalve in a non-hazardous location.5. When removing the cover, care must be taken not to scratch, scar of deform the flame path of the cover and base of the actuator, since this will negate the NEMA rating of the enclosure.6. When replacing the cover, take care that the gasket is in place to assure proper clearance after the cover is secured.7. All electrical connections must be in accordance with the specifications for which the unit is being used.8. Should the unit ever require maintenance, remove from the hazardous location before attempting to work on the unit. If the actuator is in a critical application, it is advisable to have a standby unit in stock.Electric Actuators Performance RatingMAINTENANCE/REPAIRUpon final installation of the Series WE, only routine maintenance is required. The Series WE is not field serviceable and should be returned if repair is needed. Field repair should not be attempted and may void warranty.WARRANTY/RETURNRefer to “Terms and Conditions of Sale” in our catalog and on our website. Contact customer service to receive a Return Goods Authorization number before shipping the product back for repair. Be sure to include a brief description of the problem plus any additional application notes.__________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________11©Copyright 2017 Dwyer Instruments, Inc.Printed in U.S.A. 7/17FR# 444279-00 Rev. 512__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________。
SZL20-1.25-AⅡ强度计算书
技术文件号: 共 23 页 第 10 页
名
称
符号
计
算
依
据
数
值
(三): 孔桥2 1 孔桥类型 2 孔类型 3 孔直径 4 圆周上的节距 5 横向孔桥减弱系数 (四): 孔桥3 1 孔桥类型 2 第一只孔类型尺寸 3 孔类型 4 孔直径 5 第二只孔类型尺寸 6 孔类型 7 孔直径 8 相邻两孔的平均直径 9 圆周上的节距 10 轴线上的节距 11 斜向孔桥换算系数 12 斜向孔桥减弱系数 13 斜向孔桥当量减弱系数 (五): 孔桥4 1 孔桥类型 2 第一只孔类型尺寸 3 孔类型 4 孔直径 5 第二只孔类型尺寸 6 孔类型 7 孔直径 8 相邻两孔的平均直径 9 圆周上的节距 d dp a mm mm mm 设计取定 设计取定 设计取定 圆孔 90 71 116.16 d mm 设计取定 设计取定 圆孔 52 斜向孔桥 d dp a b k
计
算
依
据
数
值 0.498 0.648
7 斜向孔桥减弱系数 8 斜向孔桥当量减弱系数 (六): 孔桥5 1 孔桥类型 2 孔类型 3 孔直径 4 圆周上的节距 5 轴线上的节距 6 斜向孔桥换算系数 7 斜向孔桥减弱系数 8 斜向孔桥当量减弱系数 (七): 孔桥6 1 孔桥类型 2 孔类型 3 孔直径 4 圆周上的节距 5 横向孔桥减弱系数 (八): 单孔1(加强) 1 孔类型 2 孔直径 (九): 孔加强1 1 加强类型 2 加强圈(管接头)壁厚 3 加强圈(管接头)焊脚高度 4 伸入筒体内长度 5 加强圈(管接头)附加壁厚 6 加强圈(管接头)有效壁厚 7 筒体理论壁厚 8 管接头内径
S01 mm h F F1 F2 F4 mm mm^2 mm^2 mm^2 mm^2 mm^2 mm^2
Merkur
3A1619KZH说明书-零配件Merkur ™ Bellows泵组件适用于注入异氰酸酯、UV 涂层和其他湿气敏感性材料。
仅适合专业用途。
有关型号信息,包括最大工作压力,请参见第 7页。
重要安全说明请阅读本手册的所有警告及说明。
妥善保存这些说明。
ti15361aII 2 G Ex h IIB T6 Gb相关手册23A1619K目录相关手册 . . . . . . . . . . . . . . . . . . 2警告 . . . . . . . . . . . . . . . . . . . . 3双组份涂料的重要信息 . . . . . . . . . . . . 5异氰酸酯条件 . . . . . . . . . . . . . . . 5涂料的自燃 . . . . . . . . . . . . . . . . 5要让 A 组份和 B 组份保持分开 . . . . . . . 5异氰酸酯的湿气敏感性 . . . . . . . . . . . 5更换涂料 . . . . . . . . . . . . . . . . . 5型号 . . . . . . . . . . . . . . . . . . . . 6泵数据 . . . . . . . . . . . . . . . . . . . 7组件辨认 . . . . . . . . . . . . . . . . . . 8安装 . . . . . . . . . . . . . . . . . . . . 9一般信息 . . . . . . . . . . . . . . . . . 9操作员准备 . . . . . . . . . . . . . . . . 9现场准备 . . . . . . . . . . . . . . . . .10接地 . . . . . . . . . . . . . . . . . . .11安装泵 . . . . . . . . . . . . . . . . . .11空气和流体软管 . . . . . . . . . . . . . .11附件 . . . . . . . . . . . . . . . . . . .12操作 . . . . . . . . . . . . . . . . . . . .13泄压步骤 . . . . . . . . . . . . . . . . .13首次使用前冲洗泵 . . . . . . . . . . . . .13扳机锁 . . . . . . . . . . . . . . . . . .13填料并调整泵 . . . . . . . . . . . . . . .14关闭并维护泵 . . . . . . . . . . . . . . .14维护 . . . . . . . . . . . . . . . . . . . . 15预防性维护计划 . . . . . . . . . . . . . 15拧紧螺纹连接 . . . . . . . . . . . . . . 15冲洗 . . . . . . . . . . . . . . . . . . 15故障排除 . . . . . . . . . . . . . . . . . . 16修理 . . . . . . . . . . . . . . . . . . . . 17一般信息 . . . . . . . . . . . . . . . . 17准备工作 . . . . . . . . . . . . . . . . 17断开泵 . . . . . . . . . . . . . . . . . 17重新连接泵 . . . . . . . . . . . . . . . 19零配件 . . . . . . . . . . . . . . . . . . . 20零配件,随型号而异 . . . . . . . . . . . 21修理配件包 . . . . . . . . . . . . . . . . . 22壁式安装配件包 . . . . . . . . . . . . . 22车式安装配件包 24E879 . . . . . . . . . . 22附件 . . . . . . . . . . . . . . . . . . 22性能表 . . . . . . . . . . . . . . . . . . . 23泵尺寸 . . . . . . . . . . . . . . . . . . . 27壁式支架安装尺寸 . . . . . . . . . . . . . . 28技术数据 . . . . . . . . . . . . . . . . . . 28California Proposition 65 . . . . . . . . . . . . . . . . . . .29Graco 标准担保 . . . . . . . . . . . . . . . 30相关手册手册描述312793Merkur Bellows 柱塞泵312796NXT ™ 气动发动机312799Merkur Bellows 喷涂套件、AA 和无气312798Merkur 静电喷涂套件警告警告以下为针对本设备的设置、使用、接地、维护及修理的警告。
奥林 星 A320 系列 便携式电化学分析仪 用户手册说明书
Thermo Scientific Orion Star A320 系列电化学便携测量仪68X001273 • 2015 年 6 月用户手册重要注释使用测量仪前请仔细阅读本用户指南。
任何不符合说明的用法都可能使保修失效并永久性地损坏测量仪。
联系信息关于Thermo Scientific™Orion™产品的协助,请通过以下方式联系技术支持:电子邮件********************************或电话 - 美国境内请致电 1-800-225-1480,美国境外请致电 +1 -978-232-6000 或传真 +1 -978-232-6031。
若需其他产品信息,请联系本地授权经销商、本地 Thermo Scientific Orion 技术销售代表或使用本手册后面页面上的“水和实验室产品”(WLP) 信息联系我们。
应用和技术资源请访问/water查看 Thermo Scientific Orion 产品并下载产品资料、用户指南和手册、软件更新和最新的应用与技术资源。
目录第 1 章仪表简介 (6)仪表概览 (6)包装列表 (8)预期用途 (9)第 2 章测量仪基础信息 (10)安装电池 (10)使用通用电源适配器(选配电源) (11)便携仪表附件 (12)Orion Star A 系列便携仪表套 (12)Orion Star A 系列便携仪野外便携包 (13)仪表连接 (14)仪表键盘 (17)功能键 (18)仪表显示 (19)测量显示图标 (21)pH 电极情况图标 (22)仪表型号和测量功能 (23)测量仪维护 (23)第 3 章测量仪设置菜单 (24)主设置菜单 (24)常规设置菜单导航 (24)通道特定方法、模式和温度菜单 (28)Method菜单 (29)Mode and Settings菜单 (32)Temperature菜单 (46)Instrument Settings设置菜单 (51)Log View菜单 (52)数据日志 (52)校准日志 (53)Diagnostics菜单 (54)测量仪自检流程 (54)电极稳定性测试流程 (55)第 4 章使用 PH 或 PH/ISE CHANNEL (56)测量仪和电极的准备 (56)pH 校准流程 (57)pH 校准编辑 (58)ORP 校准流程(相对 mV 模式) (59)ORP 校准流程(E H装置) (60)ISE 校准流程 (61)ISE 校准编辑 (62)测量流程 (63)第 5 章使用 CONDUCTIVITY CHANNEL (64)测量仪和传感器的准备 (64)电导率校准流程 (65)电导率校准编辑 (66)备用认证电池常数输入校准流程 (66)电导率标样 vs. 温度表 (67)电导率测量仪验证流程 (68)测量流程 (69)第 6 章使用 DO/RDO CHANNEL (70)测量仪和传感器的准备 (70)溶解氧校准流程 (71)空气(水饱和空气)校准 (72)水(空气饱和水)校准 (72)手动 (Winkler) 校准 (73)置零校准 (74)测量流程 (75)第 7 章数据传输和软件更新 (76)数据存储和传输设置 (76)测量读数类型设置 (76)数据日志设置 (77)导出数据设置 (78)打印机兼容性和要求 (80)计算机兼容性和要求 (81)使用 USB 到串口计算机线 (82)使用 USB 计算机线 (84)Orion Star Com 通信软件 (87)测量仪与其他计算机程序的交互 (88)Star A200-A300 测量仪远程控制协议 (89)测量仪软件升级流程 (96)第 8 章客户服务 (100)故障排除建议 (101)测量仪出厂重置流程 (102)测量仪用户重置流程 (102)合规性通知 (103)WEEE 合规性 (103)符合性声明 (104)测量仪规格 (105)订购信息 (114)测量附件,电极和溶液 (116)1第 1 章仪表简介仪表概览Thermo Scientific™ Orion Star™ A320 系列便携仪表采用坚固的 IP67 级防水仪表外壳,可在各种室外和苛刻环境下进行测试。
LCM20 操作手册 (Chinese Version)
步骤
1 从'软管固定架'上拆下液压软管
2 Laser CM20是设计与规格0,1和2的system20工
业传感器或单点采样器一同使用的。
注: '腐蚀性流体'检测仪必须连接一个特殊的 system20传感器或单点采样器。
直径
工业 规格
3 保证传感器按照油流方向的箭头安装,工作黏度2-100 cSt。
至传感器进口。
基本操作
5
2 连接黄软管
至传感器出口。
6 拧紧管接头。
现在Laser CM20已连接到要检测的流体
13 LASER CM20 © Parker Hannifin (UK) Ltd 2003
LASER CM20
基本操作
我们建议把Laser CM20连接到工作系统的传感器上5分钟后,再开始检测,以使流体状态处于稳 定。
如果通过system20传感器的油液黏度高,流量小,或者在寒冷的环境温度中,装置工作在没有沿 线加热选项的条件下,建议采用独立的流量检查。
独立的流量检测 按
1 使Laser CM20开关处于开位置。
2按
5秒钟
3 流量检测将开始, 显示器将显示。
4 30秒钟后打印机将打印出流量检测的结果。
5 要获得成功的测试, 温差△T要不大于03.60℃。
基本操作
2 观察操作控制阀的位置。
或
3 按照指示的方向把阀转90 阀的位置
能够从检测仪的顶部检查…
…或从检测仪的前面
重要: 仅当开始检测时转动阀,或者仅 当阀的转动符号
顶部
或
出现在显示器上 时转动阀。
检测将马上开始,检测将需要大约2分 钟,12个区段的时钟条码将在检测过 程中同步显示。
L-20系列利德RECT水性元现象报警开关说明书
L-20Lidec Level Alarm SwitchesThe Lidec L-20 series liquid sensing switches are specially designed for marine applications requiring a reliable liquid level alarm detection solution. The Lidec level switches perform well in applications where:✓ High Level Alarm or overfill alarm detectioncapability is required from single instrument ✓ Water ingress detection usable in all ship typeswith compact sensor footprint for mounting at difficult to reach locations✓ Level Detection in service tanks since Lidecswitches are insensitive to conductivityThe L-20 switches operate using mechanical wave propagation inside stainless steel probe. The design is fully static, without vibration or moving parts. A "self-monitoring" function ensures reliability for using sensors in safety systems. The principle used is positive safety whereby any failure of probe, electronics or transducer triggers alarm, eliminating periodical cleaning or manual testing. Thecompact and small sensor diameter allows installations through smaller holes in tanks walls and roofs. The proven Lidec technology is insensitive to changes in density, temperature or pressure, doing away with the need for calibration and ensuring quick and simple commissioning.Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.L-20-HM-22-03-01-PIB-EN; 12/2022©2022 Honeywell International Inc.MECHANICAL CONNECTIONSMECHANICAL DIMENSIONS ELECTRICAL CONNECTIONS - CURRENT ELECTRICAL CONNECTIONS - RELAY。
SZ20制动单元使用说明
希望森兰SZ20G系列制动单元使用说明希望森兰科技股份有限公司成都西南航空港经济开发区机场路181号 邮政编码:610225 电话:028-8596 4751简介SZ20G系列制动单元和制动电阻配合,用来吸收电动机制动时的再生电能,防止变频器过压。
本公司严格按照ISO9001开发,每台产品出厂前都经过严格的质量控制,它除了用在森兰变频器上,还可以用在其它品牌的变频器上。
结构合理安全可靠,经久耐用,是用户的优选产品。
使用前请仔细阅读使用说明。
技术规范1.输入电压:DC300~800V2.可额定电流连续工作,可多台一起工作,增强制动能力。
3.制动电压可选择,出厂680V±1.5%,4.故障继电器输出:故障时继电器断开,端子TB-TC连通,无故障时TA-TC连通。
5.完善的保护功能:具有过热、过流(150%额定电流)、过载等保护功能。
接线原理图制动单元DB P+ P+ N- PE 正常故障T BT A T C制动电阻保护地DC+DC-变频器图1 制动单元单台工作制动电阻R1 制动电阻R2图2 同时使用多台制动单元获得更大的制动功率型号说明电气和机械参数型号制动电阻值(Ω)适配变频器(kW)制动电压(V)W(mm)H(mm)H1(mm)D(mm)A(mm)B(mm)d(mm)SZ20G30 ≥ 22 18.5/22 680 105 200 176 120 70 190 4.5 SZ20G60 ≥ 11 30/37 680SZ20G85 ≥ 8 45/55 680125 260 230 140 80 248 Φ5.5SZ20G130 ≥5.2 75/90 680SZ20G170 ≥ 4 110 680140 300 265 180 90 286 Φ5.5SZ20G260 ≥2.6 132/160 680SZ20G380 ≥1.8 200/250 680192 340 300 195 140 327 Φ6.5使用方法怎样选配制动电阻:最小电阻阻值Rmin = 斩波电压÷制动单元额定电流,最大电阻值Rmax=1.5Rmin。
SZL3电器设备使用维护说明书
QPY54-1 主断路器箱由箱盖、吊攀、箱体、高速断路器、线路接触器、电压传感器、电流传 感器、一组充电电阻、一组经济电阻、一个圆形电连接器组成。 箱体采用耐候钢焊接结构,前后两面设有外取式活门,箱门采用铝合金结构,通过嵌在箱体 上的密封橡胶条扣压在箱体上,具有防尘、防水功能。箱内器件分左右两区,右区装有高速断路
产品 型号 用途
QPG19-1 主隔离开关箱
本产品用于地铁车辆,也可以用于其它城轨电动车辆。当线路发生故障或进行检修时,充当 隔离开关之用。该开关箱不允许带电操作。
技 术 参 数
1、主 回 路:刀形开关(DC1500V,800A)一件;刀形开关(DC1500V,100A)一件 控制回路:微动开关(DC125V,10A)两件 2、 刀形开关(DC1500V,800A)操作力:54N~80N,刀片直立手摇动时不得有晃动,刀片离开 静触头时操作力不小于 27N。 3、刀形开关(DC1500V,100A)操作力:30N~44N。
维护、修理要点
定、架修 更换接线盒的密 封橡胶条 , 检查 产品性能是否符 合要求。 方法、工具标准限 度 1) 损伤严重的应 予更换; 2) 有松弛现象的 应进行紧固 备注 特别是 8 根紧固 线圈的 长螺栓
无过热变色 或断线等异 常现象。
过热变色或断 线等异常现象。
电缆。
裂 >10% 的应及时更 换
4、质量
30 kg ± 10 %
QPG19-1 主开关箱由箱盖、 吊挂、 箱体、 一个 DC1500V、 800A 刀形开关 (MS) 、 一个 DC1500V, 100A 刀形开关(DS) 、两个 DC125V、10A 微动开关(DSS1、DSS2)和一个绝缘操作手柄组成。 外壳采用玻璃钢材料、其耐腐蚀强度及绝缘性能优异,箱体的两侧及底部均有出线孔,出线孔装
铝合金硬度计系列 W-20 说明书
铝合金硬度计系列W-201概述W-20系列铝合金韦氏硬度计又称钳式硬度计,分为W-20、W-20a、W-20b三种型号,它们体积小、重量轻、可单手操作,检测过程中不必取样,无高难技能的操作要求,适用于生产现场对材料进行快速无损的硬度检测。
可满足生产质量控制及合格判定的检测要求,是对成批产品进行逐件检测的首选仪器。
被广泛的应用于铝型材生产检验、验收检验和质量监督检验等各个环节,是提高生产合格率、节约成本必备的专业仪器。
1.1技术参数●量程:0~20HW;●精度:0.5HW;●精确测量范围:5~18HW;●测量范围(洛氏、维氏):25~110HRE、58~131HV;●测量材料:铝合金(1100~7075系列)。
1.2产品特点●仪器已通过四小时盐水(5%)浸泡试验无锈蚀不失精度,空测1000次指针不漂移,0.5米跌落100次指针不位移等严格测试,质量有保障;●小型便携式仪器,体积小、重量轻、可单手操作;●测试过程不必取样,能够无损地测试材料硬度;●对操作技能要求不高,操作技能对读数无影响,非常适于在生产现场对材料进行快速硬度检测;●能测量多种铝型材外形;●配备校准套,解决因多次满刻度校准,校准误差的问题。
1.3功能用途及适用范围1.3.1功能用途●确定铝型材有无热处理,检查热处理效果,判定铝型材力学性能是否合格;●确定铝型材是否为不适当的合金加工而成,判定铝型材合金成分是否合格;●测量不便送到实验室的过长、过重工件或装配件;●用于铝型材生产检验、验收检验和质量监督检验;●应用于国内大多数铝型材厂和许多门窗幕墙企业、工程质检及技术监督部门。
1.3.2适用范围主要用于测量铝合金(1100~7075系列)硬度。
铝合金韦氏硬度计有W-20、W-20a、W-20b 三种型号。
W-20型是通用型,用于测量厚度在0.8-6.0mm材料;W-20a型是厚材专用型,用于测量厚度在6.0-13mm的材料;W-20b型是细管材专用型,用于测量内径为6.0mm以上的管材。
浩达力电力驱动器(DC驱动器)零件清单说明书
PowerFlex DC Drive SPARE PARTS LIST Rev V.1Models 20P41AD4P1RA0NNN ….20P41AD1K4RA0NNN (480VAC / 4Q)AA A A A A BBBBCCDDDDD4,1 / 227 / 1535 / 2073 / 4086 / 50100 / 60167 / 100207 / 125250 / 150330 / 200495 / 300667 / 400830 / 500996 / 6001162 / 7001238 / 8001494 / 9006 / 345 / 25129 / 75412 / 25010 / 552 / 3014 / 7.519 / 1020P-S520L 20P-S520L A 115VAC to 24VDC 8 channel I/O converter board 1111111111111111120P-S551LRA PN-81821115VAC to 24VDC 12 channel I/O converter board 20P-S5V6220P-S5V62 A TBO-32 I/O Expansion board 11111111111111111SK-20P-4S9S14PN-54735Snubber Capacitor, 1,5uF 850Vac 666SK-20P-4S9S15PN-54736Snubber Capacitor, 2,2uF 850Vac66SK-20P-4S9S19PN-54737FAN Motor-run Capacitor, 12uF 400Vac11111SK-20P-F4M15PN-54739FUSE Ferrule 22x58mm, for field, 50A 600V 22SK-20P-F4M21PN-54742FUSE Ferrule 22x58mm, for field, 100A 600V222SK-20P-S577N PN-54744FIR-D-50 Pulse Transformer Board, 230Vac & 460 regen drive 11111SK-20P-S5D37PN-54748FNLS Fan loss detector board11111SK-20P-S5H08SK-20P-S5H08 A Main Control Bd (R-PFX) Interf. Ribbon Cable (20 conductor) to Cover Assembly 11111111111111111SK-20P-S5H95SK-20P-S5H95 A PBB-4B Power traces board 111SK-20P-S5N03SK-20P-S5N03 A SW1-31 Switching Power Supply Board 11111111111SK-20P-S5N10SK-20P-S5N10 A SW2-32 Switching Power Supply Board1111 SK-20P-S5N14SK-20P-S5N14 A SN5-31 AC Line Snubber Board, 460VAC drive111111SK-20P-S5N15SK-20P-S5N15 A FL-31 Transient Noise Filter Board, 230 & 460VAC drive 11SK-20P-S5N18SK-20P-S5N18 A FIR2-51 Pulse Transformer Board, 460VAC regen drive 1111SK-20P-S5N20SK-20P-S5N20 A SN-FC Field Snubber Board11SK-20P-S5N21SK-20P-S5N21 A FIR3-32 4B Pulse Transformer Board, 230 & 460VAC regen drive 11SK-20P-S5N22SK-20P-S5N22 A CN3 Power supply filter board 11SK-20P-S5N24SK-20P-S5N24 A PFC1A-32 Field board 111111SK-20P-S5N25SK-20P-S5N25 A PFC2A-31 Field board1111SK-20P-S5N62SK-20P-S5N62 A FIR1-51 Pulse Transformer Board, 460VAC regen drive, obsolete, use: SK-20P-S5N1211SK-20P-S5N63SK-20P-S5N63 A FIR1-52 Pulse Transformer Board, 460VAC regen drive, obsolete, use: SK-20P-S5N171111SK-20P-S5N12PN-92781FIR1-51 Pulse transformer board, 460VAC regen drive 11SK-20P-S5N17PN-92783FIR1-52 Pulse transformer board, 460VAC regem drive 1111SK-20P-S5N70PN-54758PFC40 Field board, 40Adc max.11SK-20P-S5N73PN-54761PFC70 Field board, 70Adc max.111SK-20P-S5N97SK-20P-S5N97 A SW3-32 Switching Power Supply Board 11SK-20P-S5N99PN-54762CFSF461 Overvoltage clipping board11111SK-20P-S5RP1SK-20P-S5RP1 A R-PFX32 Main Control - Regulation board 11111111111111111SK-20P-S7169SK-20P-S7169 A FUSE Ferrule 5x20mm fast, switching supply, 3,15A 250V 111111SK-20P-S725723PN-54778 4 SCR leg assembly, 2HS-PF-4Q-1K6V-830A 3SK-20P-S725724PN-54779 4 SCR leg assembly, 2HS-PF-4Q-1K6V-996A 3SK-20P-S725725PN-54780 4 SCR leg assembly, 2HS-PF-4Q-1K6V-1162A 3SK-20P-S725726PN-54781 4 SCR leg assembly, 2HS-PF-4Q-1K6V-1328A 3SK-20P-S725727PN-54782 4 SCR leg assembly, 2HS-PF-4Q-1K6V-1494A3SK-20P-S725802PN-210106FAN Assembly, F280, 460Vac, used in frame D, series B drives11111SK-20P-S725804PN-297701Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series C drives .11111SK-20P0S725805PN-297720Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series B drives to convert to Series C.11111SK-20P-S725806PN-297715Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series A drives to convert to Series C. 11111SK-20P-S5D41PN-223015DC Fan Board, 400-460Vac, 50/60Hz, used in Frame D, series B and C drives 11111SK-20P-S725801PN-54797FAN Assembly, F280, 230Vac, 2400m 3/h used in frame D, series A drives11111SK-20P-S726171PN-54798Bus bar extension for U V W power terminals, 10x100mm (required for UL installations)111SK-20P-S737F SK-20P-S737F A Module SCR2 for Armature, 460VAC drive, 1K6V 320A66 SK-20P-S75BT PN-54801Upper Cover, Black, A frame only 111111SK-20P-S764L PN-54802Bezel, Black, for PFDC Cover Assembly11111111111SK-20P-S771F SK-20P-S771F A Module SCR2 for Armature, 460VAC drive, 1K6V 500A 6SK-20P-S777H SK-20P-S777H A AC Current Transducer ETI 1168, 600A / 0,2A 2222SK-20P-S779F PN-54806Module DIODE2 for Field, 1K6V 99A 11SK-20P-S77BT PN-54807Lower Cover, Grey, A frame only 111111SK-20P-S785F PN-54808Module DIODE2 for Field, 1K6V 120A111SK-20P-S78H0SK-20P-S78H0 A AC Current Transducer ETI 1188, 200A / 0,1A 222222SK-20P-S799F SK-20P-S799F A Module DIODE2 for Field, 1K6V 40A 111111SK-20P-S79F1SK-20P-S79F1 A Module D/SCR5 for Field, 1K6V 28A 1111SK-20P-S79F3SK-20P-S79F3 A Module D/SCR5 for Field, 1K6V 15A 11SK-20P-S7F41SK-20P-S7F41 A Module SCR2 for Armature, 460VAC drive, 1K6V 210A 6SK-20P-S7F73SK-20P-S7F73 A Module SCR2 for Arm & Field, 1K6V 25A 6111111SK-20P-S7F74SK-20P-S7F74 A Module SCR2 for Armature, 460VAC drive, 1K6V 40A 66SK-20P-S7F75SK-20P-S7F75 A Module SCR2 for Arm & Field, 1K6V 55A 6611SK-20P-S7F77SK-20P-S7F77 A Module SCR2 for Arm & Field, 1K6V 90A6111SK-20P-S7F78SK-20P-S7F78 A Module SCR2 for Armature, 460VAC drive, 1K6V 130A 6SK-20P-S7F79SK-20P-S7F79 A Module SCR2 for Armature, 460VAC drive, 1K6V 160A 6SK-20P-S7G17SK-20P-S7G17 A FAN F150x55 230VAC, 191 cfm 33SK-20P-S7G29SK-20P-S7G29 A BIMETAL THERMOSTAT, 80°C ± 32SK-20P-S7G30SK-20P-S7G30 A BIMETAL THERMOSTAT 90°C ±333SK-20P-S7G33SK-20P-S7G33 A BIMETAL THERMOSTAT, 85°C ±311222SK-20P-S7G37SK-20P-S7G37 A BIMETAL THERMOSTAT, 85°C ±311Catalog NumberSAP Part #DescriptionFrame SizesArmature current [A ] / Power [HP ] sizesModels 20P41AD4P1RA0NNN ….20P41AD1K4RA0NNN (480VAC / 4Q)AA A A A A BBBBCCDDDDD4,1 / 227 / 1535 / 2073 / 4086 / 50100 / 60167 / 100207 / 125250 / 150330 / 200495 / 300667 / 400830 / 500996 / 6001162 / 7001238 / 8001494 / 9006 / 345 / 25129 / 75412 / 25010 / 552 / 3014 / 7.519 / 10Catalog NumberSAP Part #DescriptionFrame SizesArmature current [A ] / Power [HP ] sizesSK-20P-S7G49PN-54812FUSE Ferrule 14x51mm, for Overvoltage Clipping Bd. (CFSFXXX), 10A 690V 33333SK-20P-S7G71SK-20P-S7G71 A FAN 119x119x32 24VDC, 100 cfm 111222SK-20P-S7G76SK-20P-S7G76 A FAN 80x80x25 24VDC, 37 cfm 1SK-20P-S7G78SK-20P-S7G78 A FAN F150x55 24VDC, 212 cfm2SK-20P-S7G84PN-38189Fuse holder on Switching Power Supply Bd. (SW1, SW2, SW3 -board)22222222222211111SK-20P-S7GA0SK-20P-S7GA0 A BIMETAL THERMOSTAT, 70°C ±31SK-20P-S7GA1SK-20P-S7GA1 A BIMETAL THERMOSTAT, 80°C ±31SK-20P-S7GA9PN-54813BIMETAL THERMOSTAT 100°C ±311111SK-20P-S7H22SK-20P-S7H22 A AC Current Transducer TAS2, 1600A / 0,4A 22222SK-20P-S7H23PN-54815AC Current Transducer TAS2, 2400A / 0,5A22SK-20P-S7K9K PN-54816EAM 1251_5 Ribbon cable, 34 conductor, 220mm (FIR-X to R-PFX)(Pulse Transformer Bd to Main Control Bd)11SK-20P-S7P1J PN-54817EAM 1374_16 Ribbon cable, 34 conductor, 160mm (FIR-X to R-PFX)(Pulse Transformer Bd to Main Control Bd)1111SK-20P-S7P1V PN-54818EAM 1408_1 Ribbon cable, 6 conductor, 310mm (PFC-X to R-PFX)(Field Board to Main Control Bd)111111SK-20P-S7P3V PN-54820EAM 1374_7 Ribbon cable, 34 conductor, 130mm (FIR-X to R-PFX)(Pulse Transformer Bd to Main Control Bd)111111SK-20P-S7P4V PN-54821EAM 1374_8 Ribbon cable, 16 conductor, 160mm (SW-X to R-PFX)(Switching Power Supply Bd to Main Control Bd)1111111111SK-20P-S7P7K PN-54822EAM 1408_5 Ribbon cable, 6 conductor, 350mm (PFC-X to R-PFX)(Field Board to Main Control Bd)111111SK-20P-S7W0W PN-54823EAM 1251_4 Ribbon cable, 16 conductor, 100mm (SW-X to R-PFX)(Switching Power Supply Bd to Main Control Bd)11SK-20P-S713748PN-80430EAM 1374_38 Ribbon cable, 16 conductor, 450mm (SW-X to R-PFX)(Switching Power Supply Bd to Main Control Bd)11111SK-20P-S713749PN-80431EAM 1374_39 Ribbon cable, 34 conductor, 570mm (FIR-X to R-PFX)(Pulse Transformer Bd to Main Control Bd)11111SK-20P-S714088PN-80432EAM 1408_18 Ribbon cable, 6 conductor, 800mm (PFC-X to R-PFX)(Field Board to Main Control Bd)11111SK-20P-S7P3U PN-80434EAM 1406_1 Twisted pair cable, 2 conductor, AWG22, 510mm (PFC-X to FIR-X)(Field Board to Pulse Transformer Bd)11111SK-20P-S714402PN-80435EAM 1440_2 Cable, 2 conductor, AWG22, 100mm (SW-X to FIR-X)(Switching Power Supply Bd to Pulse Transformer Bd)11111SK-20P-S724682PN-80437EAM 2468_2 Twisted pair cable, 4 pole, AWG22, 600mm (Gating Field SCR T1F, T2F)11111SK-20P-S713043PN-80438EAM 1304_3 Cable, 2 conductor, AWG18, 1340mm (Fuse switch to FIR-X)(Fuse switch to Pulse Transformer Bd)11111SK-20P-S714442PN-80440EAM 1444-2 Twisted pair cable, 4 conductor, AWG22, 1800mm (CT to FIR-X)(CT to Pulse Transformer Bd)11111SK-20P-S723831PN-80442EAM 2383_1 Cable, 2 conductor, AWG22, 920mm (Thermostat to FIR-X)(Thermostat to Pulse Transformer Bd)11111SK-20P-S726421PN-80443EAM 2642_1 Cable, 3 conductor, AWG16, 900mm (CFSF-X to FIR-X)(Overvoltage Clipping Bd to Pulse Transformer Bd)11111SK-20P-S726136PN-80445EAM 2613_6 Cable, 4 conductor, AWG18, 1300mm (CD term. to FIR-X)(CD term. to Pulse Transformer Bd)11111SK-20P-S726137PN-80448EAM 2613_7 Cable, 4 conductor, AWG18, 900+1450mm (CD to CFSF-X to FIR-X)(CD to Overvoltage Clipping Bd to Pulse Transformer Bd)11111SK-20P-S726141PN-80456EAM 2614_1 Twisted pair cable, 4 pole, AWG20, 780mm (Gating T1, T01 4Q drives)11111SK-20P-S726142PN-80459EAM 2614_2 Twisted pair cable, 4 pole, AWG20, 980mm (Gating T2, T02 4Q drives)11111SK-20P-S726143PN-80460EAM 2614_3 Twisted pair cable, 4 pole, AWG20, 1130mm (Gating T3, T03 4Q drives)11111SK-20P-S726144PN-80461EAM 2614_4 Twisted pair cable, 4 pole, AWG20, 910mm (Gating T4, T04 4Q drives)11111SK-20P-S726145PN-80462EAM 2614_5 Twisted pair cable, 4 pole, AWG20, 1080mm (Gating T5, T05 4Q drives)11111SK-20P-S726146PN-80463EAM 2614_6 Twisted pair cable, 4 pole, AWG20, 1310mm (Gating T6, T06 4Q drives)11111SK-20P-S7ZRZ PN-54824Discharge Resistor, 1k5R 100W 44444SK-20P-S813G PN-54825Inrush limiting Resistor, 10R 75W 11111SK-20P-S815G PN-54827Snubber Resistor, 18R 280W 66SK-20P-S816G PN-54828Snubber Resistor, 22R 180W 666SK-20P-S81N1RA PN-38182Ckt bd conn., kit Frame A 111111SK-20P-S81N2RA PN-38183Ckt bd conn., kit Frame B 1111SK-20P-S81N3RA PN-38184Ckt bd conn., kit Frame C 11SK-20P-S81N6RA PN-80467Ckt bd conn., kit Frame D11111SK-20P-S81N4RA PN-38186Ckt bd conn., kit I/O Board only11111111111111111SK-20P-S81N5RA PN-38187Ckt bd conn., kit converter bd (8 chn)11111111111111111SK-20P-S81N7RA PN-80470Ckt bd conn., kit converter bd (12 chn)11111111111111111SK-20P-S821B SK-20P-S821B A FUSE Ferrule 6x32mm, 25A 500V 33SK-20P-S823B SK-20P-S823B A FUSE Ferrule 10x38mm, 25A 600V 222222SK-20P-S824B SK-20P-S824B A FUSE Ferrule 6x32mm, 16A 500V2222223333SK-20P-S825B SK-20P-S825B A FUSE sq. body, high speed 170M5462, 630A 700V 6SK-20P-S826B SK-20P-S826B A FUSE sq. body, high speed 170M5464, 800A 700V6SK-20P-S85B9PN-54837Field fuse holder, 2-poles, 22x58mm fuses, frame D drives11111Models 20P41AD4P1RA0NNN ….20P41AD1K4RA0NNN (480VAC / 4Q)AA A A A A BBBBCCDDDDD4,1 / 227 / 1535 / 2073 / 4086 / 50100 / 60167 / 100207 / 125250 / 150330 / 200495 / 300667 / 400830 / 500996 / 6001162 / 7001238 / 8001494 / 9006 / 345 / 25129 / 75412 / 25010 / 552 / 3014 / 7.519 / 10Catalog NumberSAP Part #DescriptionFrame SizesArmature current [A ] / Power [HP ] sizesSK-20P-S85C1PN-54839FUSE square body stud-mount, high speed, for armature leg, 1000A 700V 6SK-20P-S85C2PN-54840FUSE square body stud-mount, high speed, for armature leg, 1400A 700V 6SK-20P-S85C3PN-54841FUSE square body stud-mount, high speed, for armature leg, 800A 700V 6SK-20P-S86C2PN-54853FUSE square body stud-mount, high speed, for armature leg, 1100A 700V 6SK-20P-S86C3PN-54854FUSE square body stud-mount, high speed, for armature leg, 1250A 700V 6SK-20P-S8B28SK-20P-S8B28 A FUSE Ferrule 5x20mm slo-blow, switching supply, 1A 250V 111111SK-20P-S8B29SK-20P-S8B29 A FUSE Ferrule 5x20mm slo-blow, switching supply, 2,5A 250V 11111111111SK-20P-S8N04PN-38190Field fuse holder, frame A drive.222222222222SK-20P-S8N29PN-38191Field fuse holder, frame B & C drives.222222222222SK-DC1-CVR1-A1PN-C10434PFDC Cover Assembly - HIM Cradle (common on all Frames)11111111111111111Remark: External high speed power fuses are listed on file "Fuses for PowerFlex DC.xls".Color Code:Not For Sale Obsolete Accessory NewNo external fuses required. Armature leg fuses and fieldPowerFlex DC Drive SPARE PARTS LIST Rev V.1Models 20P41AE067RA0NNN ….20P41AE1K6RA0NNN (575VAC / 4Q)B B B B BC CD D D D D67 / 50101 / 75135 / 100270 / 200405 / 300540 / 400675 / 500810 / 6001080 / 8001215 / 9001350 / 10001668 / 1250 20P-S520L20P-S520L A115VAC to 24VDC 8 channel I/O converter board11111111111120P-S551LRA PN-81821115VAC to 24VDC 12 channel I/O converter board20P-S5V6220P-S5V62 A TBO-32 I/O Expansion board111111111111SK-20P-4S9S13PN-54734Snubber Capacitor, 1uF 850Vac666SK-20P-4S9S14PN-54735Snubber Capacitor, 1,5uF 850Vac66SK-20P-4S9S19PN-54737FAN Motor-run Capacitor, 12uF 400Vac11111SK-20P-F4M15PN-54739FUSE Ferrule 22x58mm, for field, 50A 600V22222SK-20P-S578N PN-54745FIR-D-69 Pulse Transformer Board, 575 & 690VAC regen drive11111SK-20P-S5D37PN-54748FNLS Fan loss detector board11111SK-20P-S5H08SK-20P-S5H08 A Main Control Bd (R-PFX) Interf. Ribbon Cable (20 conductor) to Cover Assembly111111111111SK-20P-S5N03SK-20P-S5N03 A SW1-31 Switching Power Supply Board11111SK-20P-S5N10SK-20P-S5N10 A SW2-32 Switching Power Supply Board11111SK-20P-S5N20SK-20P-S5N20 A SN-FC Field Snubber Board11SK-20P-S5N22SK-20P-S5N22 A CN3 Power supply filter board11SK-20P-S5N25SK-20P-S5N25 A PFC2A-31 Field board, 20Adc max11111SK-20P-S5N421PN-54749FIR2-61 Pulse Transformer Board, 575VAC regen drive11111SK-20P-S5N423PN-54751FIR3-327 Pulse Transformer Board, 575 & 690VAC regen drive11SK-20P-S5N425PN-54753SN7-32 AC Line Snubber Capacitor Board, 0,22uF, 575 & 690VAC drive111SK-20P-S5N426PN-54754FL-57 Transient Noise Filter Board, 575VAC drive11SK-20P-S5N428PN-54756SN7-33 AC Line Snubber Capacitor Board, 0,33uF, 575 & 690VAC drive1111SK-20P-S5N70PN-54758PFC40 Field board, 40Adc max11111SK-20P-S5N97SK-20P-S5N97 A SW3-32 Switching Power Supply Board11SK-20P-S5N99PN-54762CFSF461 Overvoltage clipping board1111SK-20P-S5O50PN-54763CFSF462 Overvoltage clipping board1SK-20P-S5RP1SK-20P-S5RP1 A R-PFX32 Main Control - Regulation board111111111111SK-20P-S7257210PN-81848 4 SCR leg assembly, 2HS-PF-4Q-1K8V-1215A3SK-20P-S7257211PN-81849 4 SCR leg assembly, 2HS-PF-4Q-1K8V-1350A3SK-20P-S7257212PN-81850 4 SCR leg assembly, 2HS-PF-4Q-1K8V-1688A3SK-20P-S725728PN-54783 4 SCR leg assembly, 2HS-PF-4Q-1K8V-810A3SK-20P-S725729PN-54784 4 SCR leg assembly, 2HS-PF-4Q-1K8V-1080A3SK-20P-S725802PN-210106FAN Assembly, F280, 460Vac, used in frame D, series B drives1111SK-20P-S725804PN-297701Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series C drives . 1111SK-20P0S725805PN-297720Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series B drives to convert to Series C.1111SK-20P-S725806PN-297715Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series A drives to convert to Series C. 1111SK-20P-S5D41PN-223015DC Fan Board, 400-460Vac, 50/60Hz, used in Frame D, series B and C drives1111SK-20P-S725801PN-54797FAN Assembly, F280, 230Vac, 2400m3/h used in frame D, series A drives11111SK-20P-S726171PN-54798Bus bar extension for U V W power terminals, 10x100mm (required for UL installations)111SK-20P-S726172PN-54799Bus bar extension for U V W power terminals, 5x100mm (required for UL installations)1SK-20P-S726173PN-54800Bus bar extension for C D power terminals, 10x100mm (required for UL installations)1SK-20P-S764L PN-54802Bezel, Black, for PFDC Cover Assembly111111111111SK-20P-S777H SK-20P-S777H A AC Current Transducer ETI 1168, 600A / 0,2A22222SK-20P-S779F PN-54806Module DIODE2 for Field, 1K6V 99A11111SK-20P-S799F SK-20P-S799F A Module DIODE2 for Field, 1K6V 40A1111111SK-20P-S79F7PN-54809Module SCR2 for Armature, 575VAC drive, 1K8V 130A666SK-20P-S79F9PN-54810Module SCR2 for Armature, 575VAC drive, 1K8V 320A6SK-20P-S79G0PN-54811Module SCR2 for Armature, 575VAC drive, 1K8V 500A66SK-20P-S7F73SK-20P-S7F73 A Module SCR2 for Arm & Field, 1K6V 25A1111111SK-20P-S7F75SK-20P-S7F75 A Module SCR2 for Arm & Field, 1K6V 55A11111SK-20P-S7G17SK-20P-S7G17 A FAN F150x55 230VAC, 191 cfm33SK-20P-S7G29SK-20P-S7G29 A BIMETAL THERMOSTAT, 80°C ± 32SK-20P-S7G30SK-20P-S7G30 A BIMETAL THERMOSTAT 90°C ±333SK-20P-S7G33SK-20P-S7G33 A BIMETAL THERMOSTAT, 85°C ±32222SK-20P-S7G49PN-54812FUSE Ferrule 14x51mm, for Overvoltage Clipping Bd. (CFSFXXX), 10A 690V33333SK-20P-S7G71SK-20P-S7G71 A FAN 119x119x32 24VDC, 100 cfm2222SK-20P-S7G78SK-20P-S7G78 A FAN F150x55 24VDC, 212 cfm2SK-20P-S7G84PN-38189Fuse holder on Switching Power Supply Bd. (SW1, SW2, SW3 -board)222222211111SK-20P-S7GA9PN-54813BIMETAL THERMOSTAT 100°C ±311111SK-20P-S7H22SK-20P-S7H22 A AC Current Transducer TAS2, 1600A / 0,4A22222SK-20P-S7H23PN-54815AC Current Transducer TAS2, 2400A / 0,5A22SK-20P-S7ZRZ PN-54824Discharge Resistor, 1k5R 100W44444SK-20P-S7K9K PN-54816EAM 1251_5 Ribbon cable, 34 conductor, 220mm (FIR-X to R-PFX)(Pulse Transformer Bd toMain Control Bd)11SK-20P-S7P1J PN-54817EAM 1374_16 Ribbon cable, 34 conductor, 160mm (FIR-X to R-PFX)(Pulse Transformer Bdto Main Control Bd)11111SK-20P-S7P4V PN-54821EAM 1374_8 Ribbon cable, 16 conductor, 160mm (SW-X to R-PFX)(Switching Power SupplyBd to Main Control Bd)11111SK-20P-S7P7K PN-54822EAM 1408_5 Ribbon cable, 6 conductor, 350mm (PFC-X to R-PFX)(Field Board to MainControl Bd)1111111Catalog Number SAP Part #DescriptionFrame SizesArmature current [A] / Power [HP] sizesModels 20P41AE067RA0NNN ….20P41AE1K6RA0NNN (575VAC / 4Q)BBBBB CCDDDDD67 / 50101 / 75135 / 100270 / 200405 / 300540 / 400675 / 500810 / 6001080 / 8001215 / 9001350 / 10001668 / 1250Catalog NumberSAP Part #DescriptionFrame SizesArmature current [A ] / Power [HP ] sizesSK-20P-S7W0W PN-54823EAM 1251_4 Ribbon cable, 16 conductor, 100mm (SW-X to R-PFX)(Switching Power Supply Bd to Main Control Bd)11SK-20P-S713748PN-80430EAM 1374_38 Ribbon cable, 16 conductor, 450mm (SW-X to R-PFX)(Switching Power Supply Bd to Main Control Bd)11111SK-20P-S713749PN-80431EAM 1374_39 Ribbon cable, 34 conductor, 570mm (FIR-X to R-PFX)(Pulse Transformer Bd to Main Control Bd)11111SK-20P-S714088PN-80432EAM 1408_18 Ribbon cable, 6 conductor, 800mm (PFC-X to R-PFX)(Field Board to Main Control Bd)11111SK-20P-S7P3U PN-80434EAM 1406_1 Twisted pair cable, 2 conductor, AWG22, 510mm (PFC-X to FIR-X)(Field Board to Pulse Transformer Bd)11111SK-20P-S714402PN-80435EAM 1440_2 Cable, 2 conductor, AWG22, 100mm (SW-X to FIR-X)(Switching Power Supply Bd to Pulse Transformer Bd)11111SK-20P-S724682PN-80437EAM 2468_2 Twisted pair cable, 4 conductor, AWG22, 600mm (Gating Field SCR T1F, T2F)11111SK-20P-S713043PN-80438EAM 1304_3 Cable, 2 conductor, AWG18, 1340mm (Fuse switch to FIR-X)(Fuse switch to Pulse Transformer Bd)11111SK-20P-S714442PN-80440EAM 1444-2 Twisted pair cable, 4 conductor, AWG22, 1800mm (CT to FIR-X)(CT to Pulse Transformer Bd)11111SK-20P-S723831PN-80442EAM 2383_1 Cable, 2 conductor, AWG22, 920mm (Thermostat to FIR-X)(Thermostat to Pulse Transformer Bd)11111SK-20P-S726421PN-80443EAM 2642_1 Cable, 3 conductor, AWG16, 900mm (CFSF-X to FIR-X)(Overvoltage Clipping Bd to Pulse Transformer Bd)11111SK-20P-S726136PN-80445EAM 2613_6 Cable, 4 conductor, AWG18, 1300mm (CD term. to FIR-X)(CD term. to Pulse Transformer Bd)11111SK-20P-S726137PN-80448EAM 2613_7 Cable, 4 conductor, AWG18, 900+1450mm (CD to CFSF-X to FIR-X)(CD to Overvoltage Clipping Bd to Pulse Transformer Bd)11111SK-20P-S726141PN-80456EAM 2614_1 Twisted pair cable, 4 pole, AWG20, 780mm (Gating T1, T01 4Q drives)11111SK-20P-S726142PN-80459EAM 2614_2 Twisted pair cable, 4 pole, AWG20, 980mm (Gating T2, T02 4Q drives)11111SK-20P-S726143PN-80460EAM 2614_3 Twisted pair cable, 4 pole, AWG20, 1130mm (Gating T3, T03 4Q drives)11111SK-20P-S726144PN-80461EAM 2614_4 Twisted pair cable, 4 pole, AWG20, 910mm (Gating T4, T04 4Q drives)11111SK-20P-S726145PN-80462EAM 2614_5 Twisted pair cable, 4 pole, AWG20, 1080mm (Gating T5, T05 4Q drives)11111SK-20P-S726146PN-80463EAM 2614_6 Twisted pair cable, 4 pole, AWG20, 1310mm (Gating T6, T06 4Q drives)11111SK-20P-S813G PN-54825Inrush limiting Resistor, 10R 75W 1SK-20P-S814G PN-54826Inrush limiting Resistor, 15R 75W 1111SK-20P-S815G PN-54827Snubber Resistor, 18R 280W 66SK-20P-S816G PN-54828Snubber Resistor, 22R 180W 666SK-20P-S81N2RA PN-38183Ckt bd conn., kit Frame B 11111SK-20P-S81N3RA PN-38184Ckt bd conn., kit Frame C 11SK-20P-S81N6RA PN-80467Ckt bd conn., kit Frame D 11111SK-20P-S81N4RA PN-38186Ckt bd conn., kit I/O Board only 111111111111SK-20P-S81N5RA PN-38187Ckt bd conn., kit converter bd (8 chn)111111111111SK-20P-S81N7RA PN-80470Ckt bd conn., kit converter bd (12 chn)11111SK-20P-S822Q PN-54832Snubber Resistor, 47R 75W 66SK-20P-S829B PN-54835FUSE Ferrule 10x38mm, 15A 600V 33333SK-20P-S85B6PN-54836FUSE Ferrule 14x51mm, for FL-XX board, 25A 690V 33SK-20P-S85B9PN-54837Field fuse holder, 2-poles, 22x58mm fuses, frame D drives 11111SK-20P-S85C4PN-54842FUSE square body stud-mount, high speed, for armature leg, 630A 1250V 12SK-20P-S85C5PN-54844FUSE square body stud-mount, high speed, for armature leg, 700A 1250V 12SK-20P-S85C6PN-54845FUSE square body stud-mount, high speed, for armature leg, 800A 1250V 612SK-20P-S85C8PN-54847FUSE square body stud-mount, high speed, for armature leg, 1000A 1250V 6SK-20P-S85D2PN-54850FUSE square body flush end, high speed, for armature leg, 800A 1000V 66SK-20P-S8827PN-54855Snubber Resistor, 47R 50W 66666SK-20P-S8B29SK-20P-S8B29 A FUSE Ferrule 5x20mm slo-blow, switching supply, 2,5A 250V 222222211111SK-20P-S8HI6PN-54856Module SCR2 for Armature, 575VAC drive, 1K8V 250A 6SK-20P-S8N29PN-38191Field fuse holder, frame B & C drives 2222222SK-DC1-CVR1-A1PN-C10434PFDC Cover Assembly - HIM Cradle (common on all Frames)111111111111Remark: External high speed power fuses are listed on file "Fuses for PowerFlex DC.xls".Color Code:Not For Sale Obsolete Accessory NewDiscontinuedNo external fuses required. Armature leg fuses and fieldfuses inside drive.PowerFlex DC Drive SPARE PARTS LIST Rev V.1Models 20P41AF452RA0NNN ….20P41AF1K5RA0NNN (690VAC / 4Q)C CD D D D D D D D452 / 400565 / 500678 / 600791 / 700904 / 8001017 / 9001130 / 10001243 / 11001413 / 12501582 / 1400 20P-S520L20P-S520L A115VAC to 24VDC 8 channel I/O converter board111111111120P-S551LRA PN-81821115VAC to 24VDC 12 channel I/O converter board20P-S5V6220P-S5V62 A TBO-32 I/O Expansion board1111111111SK-20P-4S9S13PN-54734Snubber Capacitor, 1uF 850Vac66666SK-20P-4S9S14PN-54735Snubber Capacitor, 1,5uF 850Vac666SK-20P-4S9S19PN-54737FAN Motor-run Capacitor, 12uF 400Vac11111111SK-20P-F4M15PN-54739FUSE Ferrule 22x58mm, for field, 50A 600V2222SK-20P-F4M21PN-54742FUSE Ferrule 22x58mm, for field, 100A 600V2222SK-20P-S578N PN-54745FIR-D-69 Pulse Transformer Board, 575 & 690VAC regen drive11111111SK-20P-S5D37PN-54748FNLS Fan loss detector board11111111SK-20P-S5H08SK-20P-S5H08 A Main Control Bd (R-PFX) Interf. Ribbon Cable (20 conductor) to Cover Assembly1111111111SK-20P-S5N03SK-20P-S5N03 A SW1-31 Switching Power Supply Board11111111SK-20P-S5N20SK-20P-S5N20 A SN-FC Field Snubber Board11SK-20P-S5N22SK-20P-S5N22 A CN3 Power supply filter board11SK-20P-S5N423PN-54751FIR3-327 Pulse Transformer Board, 575 & 690VAC regen drive11SK-20P-S5N427PN-54755FL-69 Transient Noise Filter Board, 690VAC drive11SK-20P-S5N428PN-54756SN7-33 AC Line Snubber Capacitor Board, 0,33uF, 575 & 690VAC drive11SK-20P-S5N70PN-54758PFC40 Field board, 40Adc max1111SK-20P-S5N73PN-54761PFC70 Field board, 70Adc max1111SK-20P-S5N97SK-20P-S5N97 A SW3-32 Switching Power Supply Board11SK-20P-S5O51PN-54764CFSF571 Overvoltage clipping board1111111SK-20P-S5O52PN-54766CFSF572 Overvoltage clipping board1SK-20P-S5RP1SK-20P-S5RP1 A R-PFX32 Main Control - Regulation board1111111111SK-20P-S7257213PN-54768 4 SCR leg assembly, 2HS-PF-4Q-2K2V-678A3SK-20P-S7257214PN-54769 4 SCR leg assembly, 2HS-PF-4Q-2K2V-847A3SK-20P-S7257215PN-54770 4 SCR leg assembly, 2HS-PF-4Q-2K2V-904A3SK-20P-S7257216PN-54771 4 SCR leg assembly, 2HS-PF-4Q-2K2V-1017A3SK-20P-S7257217PN-54772 4 SCR leg assembly, 2HS-PF-4Q-2K2V-1243A33SK-20P-S7257219PN-54775 4 SCR leg assembly, 2HS-PF-4Q-2K2V-1413A3SK-20P-S7257220PN-54777 4 SCR leg assembly, 2HS-PF-4Q-2K2V-1582A3SK-20P-S725802PN-210106FAN Assembly, F280, 460Vac, used in frame D, series B drives11111111SK-20P-S725804PN-297701Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series C drives . 11111111SK-20P0S725805PN-297720Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series B drives to convert to Series C.11111111SK-20P-S725806PN-297715Retrofit Kit for Fan Assembly,400-460Vac, 50/60Hz,for Frame D Series A drives to convert to Series C. 11111111SK-20P-S5D41PN-223015DC Fan Board, 400-460Vac, 50/60Hz, used in Frame D, series B and C drives11111111SK-20P-S725801PN-54797FAN Assembly, F280, 230Vac, 2400m3/h used in frame D, series A drives11111111SK-20P-S726171PN-54798Bus bar extension for U V W power terminals, 10x100mm (required for UL installations)1111SK-20P-S726172PN-54799Bus bar extension for U V W power terminals, 5x100mm (required for UL installations)1SK-20P-S764L PN-54802Bezel, Black, for PFDC Cover Assembly1111111111SK-20P-S779F PN-54806Module DIODE2 for Field, 1K6V 99A1111SK-20P-S785F PN-54808Module DIODE2 for Field, 1K6V 120A1111SK-20P-S799F SK-20P-S799F A Module DIODE2 for Field, 1K6V 40A11SK-20P-S7F73SK-20P-S7F73 A Module SCR2 for Arm & Field, 1K6V 25A11SK-20P-S7F75SK-20P-S7F75 A Module SCR2 for Arm & Field, 1K6V 55A1111SK-20P-S7F77SK-20P-S7F77 A Module SCR2 for Arm & Field, 1k6V 90A1111SK-20P-S7G17SK-20P-S7G17 A FAN F150x55 230VAC, 191 cfm33SK-20P-S7G30SK-20P-S7G30 A BIMETAL THERMOSTAT 90°C ±333SK-20P-S7G49PN-54812FUSE Ferrule 14x51mm, for Overvoltage Clipping Bd. (CFSFXXX), 10A 690V33333333SK-20P-S7G84PN-38189Fuse holder on Switching Power Supply Bd. (SW1, SW2, SW3 -board)2211111111SK-20P-S7GA9PN-54813BIMETAL THERMOSTAT 100°C ±311111111SK-20P-S7H22SK-20P-S7H22 A AC Current Transducer TAS2, 1600A / 0,4A2222222SK-20P-S7H23PN-54815AC Current Transducer TAS2, 2400A / 0,5A222SK-20P-S7K9K PN-54816EAM 1251_5 Ribbon cable, 34 conductor, 220mm (FIR-X to R-PFX)(Pulse Transformer Bd toMain Control Bd)11SK-20P-S7P7K PN-54822EAM 1408_5 Ribbon cable, 6 conductor, 350mm (PFC-X to R-PFX)(Field Board to MainControl Bd)11SK-20P-S7W0W PN-54823EAM 1251_4 Ribbon cable, 16 conductor, 100mm (SW-X to R-PFX)(Switching Power SupplyBd to Main Control Bd)11SK-20P-S713748PN-80430EAM 1374_38 Ribbon cable, 16 conductor, 450mm (SW-X to R-PFX)(Switching PowerSupply Bd to Main Control Bd)11111111Catalog Number SAP Part #DescriptionFrame SizesArmature current [A] / Power [HP] sizes。
锚杆拉拔仪说明书
SW 系列锚杆拉拔仪使用说明书上海荣计达实验仪器有限公司一、概况我公司是专业从事研制开发锚杆拉力计液压机械及公路仪器生产厂家,本厂产品精良,技术力量雄厚,加工设备齐全,每项产品从设计到品质绝对可靠,实用性强,并具有良好的售后服务,能让用户买的放心,用着舒心,多年来深得用户信赖。
该拉力计由手压泵、液压缸、压力表及高压胶管等部分组成。
其中SW-200/300型手压泵为高、低压双径柱塞式设计,高压高效,泵体采用精密铸钢制造,使用寿命长。
液压缸为中空自复位式,SW-200与300型带有提把并可通过快速接头与高压胶管相接。
数字压力表读数直观,可直读锚杆拉力值。
该系列拉力计结构紧凑、携带方便、体积小、重量轻。
拉力计手动泵亦可作为通用小流量高压油的动力源。
二、主要技术参数指针压力表精度等级:1.5MPa数显压力表精度:1级三、结构特征与操作步骤:3、油缸工作时底部应摆平放稳,垂直受力。
不得超行程工作。
4、加注液压油应干净。
5、被测锚杆所受压力可在压力表上的读数(兆帕MPa)并在换算表中查出相应的总拉力(KN),数显表直读拉力值。
五、常见故障及排除方法ML型系列锚杆拉力计结构见图1ML型系列锚杆拉力计结构见图11注油阀2储油筒3泵体4卸荷阀5指针表6油管7快速接头8液压缸图1操作程序请按以下步骤进行:1、检查油量如液压缸活塞没有完全缩回缸体内时,应首先通过油管连接至手压泵,逆时针方向拧松泵体上的卸荷阀,使千斤顶中的液压油排回到手压泵储油筒中。
拧开注油阀,检查油量,如油不满,可加注N46号耐磨液压油或20号机油。
2、排气液压系统组装好后,储油筒、油管及液压缸中常混有空气,为使液压系统正常,这些空气必须排掉。
方法是,将手动泵放在比液压缸稍高的地方,压动手动泵,使液压油缸活塞伸出,再打开卸荷阀,使活塞缩回,连续几次即可。
必要时可打开注油阀,排除储油筒内空气。
3、检测锚杆将油管与千斤顶连接,按上述1、2项要求进行油量、排气及压力表检查。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
SZL20-1.6-SW型锅炉设计说明书
XXXXXX锅炉有限公司
2014年12月
技术说明书
一、锅炉用途
本锅炉主要用于企业、事业单位供热,供汽。
二、锅炉参数
额定蒸发量 20t/h 额定工作压力 1.6MPa
蒸汽温度 203 0C 给水温度 60 0C
设计效率≥78 %排烟过量空气系数 1.65
辐射受热面积 76.5m2省煤器受热面积 177.6 m2
对流受热面积 475.2m2空气预热器受热面积 102.6m2
锅炉正常水容积 16.5 m3排烟温度 162 0C
排污率: 5%
燃料消耗量: 3786 kg/h 总耗电功率 225.7KW
锅炉安全稳定运行的工况范围: 80~100 %
排烟过量空气系数:1.65
三、设计燃料特性:(生物质颗粒)
四、锅炉基尺寸:
1、上锅筒中心标高: 5755
2、下锅筒中心标高: 3155
3、锅炉本体与链条炉排结合处标高: 2530
4、最大件运输尺寸:(长×宽×高) 9.6×4.16×2.68 10.5×3.8×3.86
5、最大体运输重量:(t)~66.8
6、锅炉金属耗量(t):锅炉本体耗钢量 25.5 ,钢结构耗钢量(t):~35.7 ,
炉排耗钢量(t): 13.948
五、结构简介
该锅炉为组装水管蒸气锅炉,采用双锅筒纵置式链条炉排锅炉的结构方式,主要部件在厂内组成二大件出厂,上部(锅炉本体)大件及下部(链条炉排)大件,二大件在工地上合扰后只需进行下部炉墙的砌筑,烟风道、管道、仪表、阀门、出渣机等安装,经检验合格后,接通水电即可投入运行,本锅炉具有结构紧凑,安装使用方便,锅炉效率高,基建投资省等优点,
1、锅炉的汽水系统流程:
软化水水箱水泵省煤器
对流管区下锅筒
上锅筒
下降管集箱
上锅筒主蒸汽阀
2、烟气系统流程
燃料自煤斗通过煤闸门,随炉排缓慢地进入炉膛,或经喷料口喷入炉膛,着火燃烧,燃烧后产生的烟气由炉膛经燃烬室进入对流段,由对流段进入省煤器、空气预热器、除尘器,然后由引风机抽引通过烟囱排向大气。
3、灰渣系统流程:燃料经燃烧后生成的灰渣在炉排尾部落到渣坑由出渣机排出,漏煤和漏灰随链条炉排带至前部的落灰斗内掏出,烟气中的飞灰一部分在对流管束沉降下来,由上部落灰门排至炉排上,其余部分经除尘器分离后进入灰坑内。
4、鼓风机系统流程:
空气(进风温度20℃)由鼓风机送入空气预热器,经链条炉排二侧风道,再经各自调节扇形调风门进入风室,穿过链条炉排面燃料层进入炉膛内。
5、锅炉燃烧结构布置情况:
a 炉排有效面积:22.84m2 ;炉排通风截面比:6.85%;
b 前后拱覆盖率:81.5%
c 炉排热强度:797.3KW/m2
d 炉膛容积热强度:362.9 KW/m2.
六、性能特点
1、本锅炉吸取快装锅炉的优点:上部本体大件和由链条炉排及料斗组成的下部大件,二大件在工地合拢后只需砌筑下部炉墙即可不投运,所以安装方便,周期短,费用少。
2、本锅炉结构紧凑,占地面积少,外形美观大方,锅炉房只需单层布置。
所以土建投资少。
3、本锅炉操作方便,运行平稳,开炉升压快,出力足。
4、配套辅机齐全,鼓引风机、水泵、齿轮箱、除尘器等均能满足锅炉负荷要求。
5、锅炉配备齐全的热工监测仪表,电控操作台,鼓、引风机开度,炉排转速可自控操作。
6、锅炉送风系统采用仓式的双侧送风装置,各风室可各自独立调节,漏风小,可调性强,能较好地适应链条炉排燃烧特性的要求。
7、炉排采用加厚炉排片,具有自动清渣的功能,通风效果好,漏颗粒率低。
七、出厂情况
该锅炉出厂时分件包装如下:
1、锅炉上部大件:即锅炉本体,上部炉墙,钢架,保温层。
2、锅炉下部大件:即链条炉排、煤斗,看火门,拨火门等(下部炉墙在工地由安装队砌筑)
3、省煤器组件
4、空气预热器
5、平台扶梯组件。
6、落灰斗和出灰装置。
7、调速装置。
8、鼓风机,包括电动机及鼓风机机座。
9、引风机,包括电动机和引风机机座。
10、有关锅炉风道连接管。
11、刮板出渣机
12、电控箱
13、水泵和锅炉范围内的仪表、阀门、管道零件。
14、司炉工具
15、备品备件。
16、砌筑下部炉墙所需异形耐火砖及部分保温材料。
17、技术文件。
a锅炉总图等有关部件组件图,详见供应用户图纸目录。
b受压元件强度计算书或汇总表,安全阀排放能力计算书,热力计算汇总表。
烟风阻力计算汇总表。
c锅炉安装使用说明书及各辅机的使用说明书。
d产品质量证明书
八.配套辅机一览表
注:图中辅机配套件按用户合同要求提供。
九.技术依据
该蒸汽锅炉从设计、制造到安装严格执行以下标准:
1) NB/T47034-2013《工业锅炉技术条件》
2) 《锅炉安全技术监察规程》
3) 《特种设备安全监察条例》
4) GB/T16507.1~8-2013《水管锅炉》
5) GB50273-2009《锅炉安装工程施工及验收规范》
6) GB/T1576-2008《工业锅炉水质》
7) GB10180-2003《工业锅炉热工性能试验规程》
8)TSG0002-2010《锅炉节能技术监督管理规程》
9) GB13271-2014《锅炉大气污染物排放标准》
10) JB3375-2002《锅炉用材料入厂验收规则》
11) JB/T3721-2002《链条炉排技术条件》
12) JB/T10354-2002《工业锅炉运行规程》
13) GB/T1804-2000《一般公差未注公差的线性和角度尺寸的公差》
14) GB50126-2008《工业设备及管道绝热工程施工规范》。