电气主接线图

合集下载

电站变电所电气主接线图(含说明)

电站变电所电气主接线图(含说明)
220kV I母220kV II母110kV套管CT:3(TMY-125X10)HY5WZ-17/45W110kV中性点设备:YH1.5W-72/186WLJW1-10W,400/1AGW13-63W/630LRB-110,200,400,600/1A,(两只)LRB-60,200,400,600/1A,(两只)LR-110,1200,1800,2400/1A,(一组)LRB-110,1200,1800,2400/1A,(两组)GW13-110W/630ALJW1-10W,200/1AYH1.5W-144/320W220kV中性点设备:110kV中性点套管CT:220kV中性点套管CT:2xLGJX-500/45YH10W-108/281WYH10W-204/532WLRB-220,800,1200,1600/1A,(两组)LR-220,800,1200,1600/1A,(一组)Uk1-2=14% Uk1-3=50% Uk2-3=35%220%%P8X1.5%/115/10.5kV#1主变压器容量比:180/180/90 接线组别:YN,Yno,dll220kV套管CT:SFSZ9-K-180000/2200.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2x600/1A2500A,50kA5P30/5P30电流互感器GW7-220IID(W)5P30/5P30/5P30C备用一BA出线二BCLGJX-630/55A#1主变间隔C备用三变主2xLGJX-500/45YH10W-108/281WYH10W-204/532W#2主变压器#1同(预留)#3主变压器(预留)#4主变压器#3主变间隔#2主变间隔#4主变间隔备用四CBABALDRE-130/116LDRE-130/116变主#1同隔间母联2x(LGJX-630/55)5P30/5P30/5P305P30/5P30/0.52x1200/1A电流互感器弹簧机构4000A,50kA断路器GW16-220D(W)2500A,50kA氧化锌避雷器LGJX-400/352500A,50kAGW16-220D(W)YH10W-204/532WTYD-220/ 3-0.0075H电压互感器(三相)220/ 3:0.1/ 3:0.1/ 3:0.1/ 3:0.1一同出线出线一BCA5P30/5P30/5P300.5/0.2S4000A,50kAGW16-220(W)2500A,50kAGW16-220D(W)断路器弹簧机构2500A,50kA5P30/5P302x1200/1A电流互感器GW7-220IID(W)B、C相:OWF-220/ 3-0.005HA相:TYD-220/ 3-0.005HXZK-1600-1.0/40XZK-1600-0.5/402x(LGJX-400/35) I母母线设备II母母线设备设母同 I母线备SC11-400/11LGJX-300/40LDRE-130/116LDRE-130/1162000A,40kAGW4-126IID(W)GW16-126(W)GW16-126D(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P302x400/1A电流互感器3150A,40kA弹簧机构TYD-110/ 3-0.01H断路器A相:ACBCBA出线二出线一#1主变一出同线一出同线一同出线TBB22-10-100205组/334M-2BLXGN2B-12(Z)XHDCB-500/11DKSC-500/11 500kVA,ZN#1接地变10kV I段 3(TMY-125X10)XGN2B-12(Z)XGN2B-12(Z)#1母设10回#1站用变XGN2B-12(Z)ABCBAC出线三出线四#2主变同一出同线变#1主CBA#3母设#4母设10kV IV段10kV III段#3接地变#4接地变母联 Ⅱ母母线设备 Ⅲ母母线设备110kV Ⅰ母110kV Ⅳ母110kV Ⅱ母110kV Ⅲ母分段10回TBB22-10-100205组/334M-2BLTBB22-10-80165组/334M-2BL Ⅳ母母线设备 Ⅰ母母线设备2000A,40kALGJX-240/30TYD-110/ 3-0.02HYH10W-108/281W0.1/ 3:0.1/ 3:0.1220/ 3:0.1/ 3:GW4-126D(W)设母同 I母线备2000A,40kAGW16-126D(W)断路器3150A,40kA5P30/0.5/0.2S5P30/5P302xLGJX-500/45弹簧机构2x600/1A电流互感器母联CBACBA出线五#3主变ABC出线六一同出线断路器2xLGJX-500/453150A,40kAGW4-126IID(W)2000A,40kA5P30/0.5/0.2S5P30/5P30/5P30弹簧机构2x600/1A电流互感器2000A,40kAGW16-126D(W)GW16-126(W)备用 CBA#4主变备用 CBA备用 CBA出线七CBA备用4回一同出线图中实线设备为本期建设部分,虚线设备为预留扩建部分。说 明:3(TMY-125X10)YH10W-108/281W10kV IIA段 3(TMY-125X10)线5回馈母同I#2A母设设母同#1#2接地变器同I母电容#2站用变变#1同接地变站同#1TBB22-10-100203组/334M-2BLTBB22-10-100202组/334M-2BL10kV IIB段 3(TMY-125X10)器同I母电容5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台LZZBJ9-10Q,400~600~800/15P20/0.5/0.2S 15VA, 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只LZZBJ9-10Q,800/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)ZR-YJV22-8.7/15-1*400GN30-10D/1250A,31.5kA,1组10/√3:0.1/√3:0.1/√3:0.1kV0.2/0.5/3P 30/40/150VA HY5WZ-17/45 1组LZZBJ9-10Q,150/1 ,5P20பைடு நூலகம்0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只XGN2B-12(Z)LZZBJ9-10Q,150/1 ,5P20/0.5/0.2S 15VA 3台ZN28-1250-31.5kA 1台GN30-10D/1250A,31.5kA,1组GN30-10/1250A,31.5kA,1组HY5WZ-17/45 1组JN15-12,1组TY-LJK%%C160J,75/1A,5VA,1只GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/1 15VA/15VA 3台5P20/0.5XGN2B-12(Z)XGN2B-12(Z)ZN28-4000-50kAGN30-10/4000A, 1台50kA,1组ZR-YJV22-8.7/15-3*240ZR-YJV22-8.7/15-3*240XGN2B-12(Z)5P20/5P20/0.2S 15VA/15VA/15VA 3台ZN28-4000-50kA 1台GN30-10/4000A,40kA,1组LMZJ-10Q,4000/1/1/1 XGN2B-12(Z)GN30-10/4000A,1组LMZJ-10Q,4000/1/15P20/0.5,15VA/15VA 3台#2B母设设母同#1线5回馈母同IJW6-252W/630AJW6-252W/630A电流互感器2x600/1A5P30/5P305P30/0.5/0.2S断路器,弹簧机构3150A,40kAGW4-126D(W)2000A,40kAGW4-126D(W)2000A,40kA11%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11SC11-400/1111%%P2X2.5%%%/0.4kV 400kVAUd=4%%%,D,yn11设母同 I母线备设母同 I母线备母同 I母联C备用二BA2006.04.25例比APPROVED BY审 定AUDITED BY核 定设 计DESIGNED BYCHECKED BY校 核NO图 名图号TITLEPROJECT工程名施工时间TIME审 核AUDITED BY设计阶段220kV XX变电站 工程电气主接线图专业会签日期专业会签日期QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

35kV变电站主接线及总平面图

35kV变电站主接线及总平面图
电气主接线图馈电4回1#电容器(1000kvar)馈电4回1#站用变1#主变V5#母线35kV4#母线GW5-35IIW1000A 20kALRD-35300~600/120VALW8-351600A.25kALR-35 0.5S300~600/1GW5-35IIDW1000A 20kA同左3110P20/10P2032345LW8-351600A.25kALRD-3510P20300~600/120VAGW5-35IIW1000A 20kA300~600/120VAGW5-35IIW1000A 20kAGW5-35IIW1000A 20kARW10-35/0.5A35 0.10.1JDX6-35HY5WZ-51/1223 3 3同左SZ9-6300/3535+3X2.5%/10.5Ud=7.5%Y.d11本期容量同左LZZBJ9-10600/5A15VA.10P1515VA.0.5SVB21600A40kA左同LZZBJ9-1015VA.0.5S10VA.10P1525kA1600AVB2kV3 3 310 0.1JDZX9-10HY5WZ-17/43.50.1kVXRNP1-12/0.5A左同备用馈电2回左同备用馈电2回2#站用变10P20/0.5s20VACWC-24/3150600/5A31.5kA.4S100/5A.10P10ZRC-YJY22-8.7/15SC9-100/10.5TY-LJK120JUd=4%Dyn11-3X120mmLZZBJ9-1025kA10VA.10P15JNH1-1215VA.0.5S600/5A630AVB210.5+2X2.5%/0.4kV25kA.4S100/5A.10P10 1VAZRC-YJY22-8.7/15kVTY-LJK120J-3X120mm225kA10VA.10P15400/5ALZZBJ9-1015VA.0.5SJN15-10630AVB231.5kA.4S-3X120mm100/5A.10P10 1VAZRC-YJY22-8.7/15TY-LJK120J25kA10VA.10P15JNH1-1215VA.0.5S600/5ALZZBJ9-10630AVB22452#电容器(1000kvar)10P20LRD-3515VA.10P1510VA.10P1531.5kA.4S10.5+2X2.5%/0.4kVDyn11Ud=4%ZRC-YJY22-8.7/15-3X120mmSC9-100/10.5100/5A.10P10TY-LJK120J25kA10VA.10P15JNH1-1215VA.0.5S600/5ALZZBJ9-10630AVB2ZRC-YJY22-8.7/15kV100/5A.10P10 1VATY-LJK120J-3X120mm210VA.10P15JN15-1015VA.0.5SLZZBJ9-1025kA.4S400/5AVB2630A25kA-3X120mmZRC-YJY22-8.7/15100/5A.10P10 1VATY-LJK120J25kA10VA.10P15600/5A31.5kA.4SJNH1-12LZZBJ9-1015VA.0.5SVB2630AFEDCBAFEDACB1234567812435687电气总平面布置图2#变主控室外墙中心线主变中心线主变架构中心线道路中心线35kV架构中心线围墙中心线围墙中心线35kV架构中心线35kV架构中心线道路中心线主控室1# 30m2# 30m化粪池值班室休息室厨房厕所警卫室电容器室10kV开关室1234567891011121314151617CBAABCCBACBACBACBA1821201918171615%%p0.00-0.4501#变cbacabF1527F152720192221165048001200650038006360}6600}3600}1000}消防泵房深井泵房1150}1550}2700}1400240080203500}3500}765432189101112131410006001500600600F152712016001# 2# ACBACB16001650160017005400122005000720050001100020700500174051805200080005000720050003800176003300330033003300100050012005900800071055x5000=25000道路中心线3640}3895}60003500}CBAbacCBAbac1# 2# FEDCBAFEDACB1234567812435687650038600{\f宋体|b0|i0|c134|p5430007000{\f宋体|b0|i0|c134|p54{\f宋体|b0|i0|c134|p548120{\f宋体|b0|i0|c134|p547x800=560035001200322080002100R7000{\f宋体|b0|i0|c134|p5435001200120012001200编辑部:ivpinfo@本图纸由浩辰ICAD软件提供技术支持网易 电气 中国电气行业网络家园;因为专业,所以完美网易 NETEASE ==R7000QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

电气一次主接线图课件

电气一次主接线图课件
电气一次主接线图课 件
目录
• 电气一次主接线图基础知识 • 电气一次主接线图实例解析 • 电气一次主接线图在工程中的应用 • 电气一次主接线图常见问题与解决
方案 • 未来电气一次主接线图的发展趋势
01
电气一次主接线图基础知识
定义与作用
定义
电气一次主接线图是表示电力系统中的高压电气设备( 如发电机、变压器、断路器、隔离开关等)及其连接方 式的一种图形表示。
根据工程实际情况,制定多个接线方案,通过技 术经济比较,选择最优方案。
施工与安装
01 安装前的准备
确保施工现场安全,准备所需的工具、材料和设 备。
02 设备安装
按照设计图纸和规范要求,安装电气设备、母线 和导体等。
03 接线与调试
完成电气设备的接线工作,并进行调试,确保设 备正常运行。
运行与维护
统的安全、稳定运行具有重要意义。
电气一次主接线图在工程中
03
的应用
设计与规划
01 确定电源和负荷位置
根据工程需求,确定发电厂、变电站的位置和容 量,以及负荷的分布和需求。
02 选择设备与导体
根据电压等级、电流大小和设备的功能,选择合 适的电气设备(如变压器、断路器、隔离开关等 )和导体材料。
03 优化接线方案
日常巡检
定期对电气设备进行巡检 ,检查设备的运行状态和 接线情况。
预防性维护
根据设备的运行状况和维 修周期,制定预防性维护 计划并实施。
故障处理
发现设备故障或异常时, 及时进行处理,确保系统 安全稳定运行。
电气一次主接线图常见问题
04
与解决方案
图纸错误与缺陷
图纸错误 图纸缺陷
图纸中可能存在文字、符号、线条、颜色等方面的错误 ,导致无法正确理解电气设备的连接关系和功能。

电气课件主接线图

电气课件主接线图
备用电源:
明备用方式,引自110KV,采用有载调压变压器, 只设一个高压开关在焦电110KV升压站,网控控制。
6KV厂用分支采用两级开关
1.便于装设差动保护,使分支电缆故障快速切 除。
2.负荷或母线故障时,分支过流可以动作,从 而避免高厂变越级跳闸。
3.分支电缆检修时,厂用段可不停电。 4.两个开关互相切断负荷,防止对侧开关开关
故障(油少)而不能灭弧。
6KV电动机和低压变压器的接引原则:
▪ 容的同一用途的A、B两组辅机,应分别接在6KV
厂用A、B段。 ▪ 对于各机组在工艺上属于同一系统中的有两台以上
的辅机,应接在本机同一分段厂用母线上,不得交 叉接在二段母线上。 ▪ 对于每台机仅有单台的辅机,可接在6KV厂用A或B段 上,但应使负荷分配合理。 ▪ 同一类型的全厂公用辅机,应分散接在不同机组的 厂用母线上,以减少各机组厂用电系统故障对公用 系统的影响。
一、电气主接线的基本接线形式
▪ 汇流母线:
▪ 单母线、单母线分段、单母线分段带旁母、 双母线、双母线分段、双母线带旁母、2﹨3接
线、变压器-母线
▪ 无汇流母线:
▪ 单元及扩大单元接线、桥型(内、外)接线、 角型接线
电气主接线图的作用
电气主接线图对电气设备的选择、配电装 置的布置、电能的质量和安全运行等都起决 定性作用。所以电气专业人员必须熟悉掌握 电气主接线图
▪ 可靠性较高。单元接线的最突出的特点就是开关设 备少,操作简单,设备少相对来说也就是减少了设 备的故障率,操作简单也就减少的设备误操作的次 数,所以可靠性相对也就提高了。双母线接线配电 装置复杂,运行中隔离开关作为操作电器,国内目 前尽管采取了很多的措施、规定来避免倒闸操作事 故,可还是容易发生误操作事故。双母线接线方式 隔离开关多,这对实现自动化控制不便。当母线系 统故障时,有可能要切除较多的线路和电源。另外 我公司距春林变电站不远,仅有7公里,线路发生永 久性故障的概率较小,对我公司单元接线方式可靠 性影响不大。

电厂烟气脱硫电气主接线图

电厂烟气脱硫电气主接线图
2B脱硫变1B脱硫变2A脱硫变1A脱硫变6.3 2X2.5%/0.4KV380/220V脱硫1APCIe=1600A50kA+-6.3 2X2.5%/0.4KV-+Ie=1600A50kA380/220V脱硫1BPCIe=1600A50kA6.3 2X2.5%/0.4KV-+Ie=1600A50kA380/220V脱硫2APC6.3 2X2.5%/0.4KV-+380/220V脱硫2BPC31.5KAIe=1600AIe=200AD31.5KAIe=200A6KV脱硫I段40KA31.5KAIe=200A31.5KA40KAIe=1600AIe=200A至厂用6KV1A段至厂用6KV1B段31.5KAIe=1600AIe=200A40KA31.5KA31.5KAIe=200AIe=200A6KV脱硫II段D31.5KA40KAIe=1600AIe=200A至厂用6KV2A段至厂用6KV2B段虚线框范围为脱硫岛工作范围浙江大学蓝天环保设备工程有限公司}电气系统接线图设备\P名称图纸编号A2 (594\f宋体|b0|i0|c134|p2×}594)氧化风机1B2200kW浆液循环泵1A700kW说明:虚线框范围内为脱硫岛工作范围浆液循环泵1D900kW浆液循环泵1C800kW220kW真空泵1AIe=3150A, Ik=40kA420kW氧化风机1A增压风机1A6kV 脱硫 1A段低压脱硫变ASCB10-2000/10Dy11Ud=10%6.3%%p2X2.5%/0.4kVMMMMMMM氧化风机2A球磨机2A560kW浆液循环泵2B900kW浆液循环泵2C备用氧化风机2B420kW800kWIe=3150A, Ik=40kA6kV 脱硫 2A 段M备用M380V脱硫保安A段380V脱硫保安B段M备用M备用380V脱硫PC1段380V脱硫PC2段1#机6kV厂用电工作1A段2#炉6kV厂用电工作2A段2#炉保安段1#炉保安段380V脱硫公用MCC段 FGD废水处理MCC6.3%%p2X2.5%/0.4kVUd=10%Dy11SCB10-2000/10低压脱硫变BIe=4000A, Ik=50kAIe=4000A, Ik=50kAIe=3200AIk=50kAIe=630A, Ik=40kAIe=1000A, Ik=40kA脱硫照明变压器Ud=4%Y,yn0SC9-150/ 0.4脱硫照明、检修MCC增压风机1B增压风机2B增压风机2A2200kW浆液循环泵2A700kWMMMMMM球磨机1A560kW220kW真空泵2AMM800kW浆液循环泵1BM800kW浆液循环泵2DIk=50kAIe=3200AIe=2000AIk=40kAIk=40kAIe=2000A湿法脱硫工程电气主接线图本工程除照明、控制之外,系统为不接地系统。中国专业人士的网络家园;因为专业,所以完美tEase电气在线 编辑部:ivpinfo@==QQ:447255935Email:xingxinsucai@ TEL:星欣设计图库QQ:396271936

变电站电气主接线图

变电站电气主接线图

第5、6章图形第五章图形L1 L2 L3 L4A i i hQSL 1 J J 1QF J_ _L A J.Q$ WB 「. 「__________________I L L1L2 L3 L4QF _L _L 丄QS电源i 电源n 图5-1不分段的单母线接线WBQFd电源I电源n 图5-2单母线分段接线WBaA Q SE1 { 丄 1 \L.丄L-I II II1QF QFa丄 丄 丄丄 丄WBL:L1L2QSaJWBa\ QSa>丄1丄 T1 丄WB |1段——T二 一na电源I 电源H图5-3单母线带旁路母线接线II J\ QFdf__________ I 」电源I电源H图5-4单母线分段带旁路母线接线电源I图5-5分段断路器兼作旁路断路器接线 图5-6旁路断路器兼作分段断路器接线L 1L2QS QS 2WBaQSa=丄 \ QS1QF1 J QFa2QFL ’丄LL2L 1QS 5QS 3[段H 段士QSWB Q3电源IL1 L2 L3 L1 L2 L3U I段■丄II--- ------------- 11QSi」TQSi -hr1QFQSU QQFjQS iL 1 br2QFWB丄□_1— 1 1n __ WB1丄」RTiU段.I段.QS1QS 1QS1QF QF. 2QF 电源I电源I图5-7双母线接线图5-8用母联断路器代替岀线断路器时电流的路径L2 L3 L4L1QFj1图5-9双母线分段接线L1L2 L3(b)图5-10双母线带旁路接线(b )母联断路器兼作旁路断路器接线(一)Jp\WBaL丄QFaL1L2 电源IWBL3电源U图5-10双母线带旁路接线(a)标准接线L1L2 L2WB电源I(C)图5-10双母线带旁路接线 (c)母联断路器兼作旁路断路器(二)WBWB_LQFj_T 4L -L .QS n \rLr电源i 电源n图5-11 一台半断路器接线L 1L2L 1L2上 1QF2QFQS2 2T(b)(a )_L丄 _L_L±G (a) (b)(c)1TQS1-(a )发电机—变压器单元 (b )发电机—三绕组变压器单元 (c )发电机—自耦变压器单元图5-12桥形接线 (a )内桥接线; (b )夕卜桥接线图5-14扩大单元接线1QF 2QF3QF-K —图5-13单元接线/ GG3QF9WLGQ-'(b) (a)图5-15发电机一变压器一线路单元接线4(a)r4图5-16多角形接线(a)四角形接线 (b)三角形接线LX . h(b)图5-17例5-1方案接线图(a )方案5-1-1接线,(b )方案5-1-2接线近区负荷10KV35KVG 1GG 2G3X 3.2MW(a)(b)近区负荷 10KV6.3KV图5-18例5-2方案接线图(a)方案5-2-1接线,(b)方案5-2-2接线,(c)方案5-2-3接线注:图5-19见:“主接线厂用电实例”图J:I 1(b)(c)丄I1::'oTMY-100X8ZN21-10/1250配CD10DLZZBJ-101000/50.5/10P励磁互感器(厂家配套)RN2-6/0.5ADJ-6 :v3励磁变(厂家配套):x (ZR-YJV 226/3 X240)SFWG8000-6/4950 Je=6.3kVe=916.45ACO® =0.8L ZX -10Q800/5 0.5/10PI IdTYD-110/v-0 07HGW4-110DW/630左接地GW4-110DW/630双接地LCWB-110100/50.2/0.5/10P/10PLW25-126—1250A 40kAGW4-110DW/630左接地LGJ-120SF9-20000/110Y,d11121±3X2.5 %/6.3kVJ k%=10.5%TMY-100X8IFZJ-102000/5.5/0.5/3 10/10PGW3-60G/400△Y1W-73/15 JDCF-110110 0.1 0.1 01v3 v3 V3 .GW4-110DW/630双接地Y5W1-100/260ZN21-10/2500配CD10H3TZN21-10/I配CD10DLZZBJ-10100/50.5/10PZR-YJV22-6/3SC9-800/6.3D,yn116.3 ±5 %/0.4kVUd%=7LMZ1-0.5 1200/5LMY10X8-40 X8DW15-1200 DW15-1200ZR-YJV22-10/3 X50ZN21-10/630配CD10DLZZBJ-10100/50.5/10PZR-YJV22-10/3 X50SC9-800/10D,yn1110±5 %/0.4kVUd%=7LMZ1-0.5 1200/5_MY10X&40 X8DW15-120010kV外来电源RN2-10/0.5AHY5WZ-17/5110/0.1kV 图5-19某水电站电气主接线全图图5-20地区变电所接线2X10MVA图5-21终端变电所接线第六章图形(a)(b)图6-1设两台厂变的厂用电源引接方式图6-2丿用负荷供电回路图6-3见“主接线厂用电实例”图配电屏型号GGD36 GGD-36(改) GGD10 GGID36(改)GGD36 配电屏编号 12345馈线名称集小井小 --- 动力箱吊车整 冬流器一安 云 .装场 〕力箱备用分卜电箱分电箱生活区 备用动1#机,#厂变进线母线分段 1#厂变进线2#机 动力盘备用备用整流器二室分电箱动力箱气系统 备用明分电箱备用回路电流(A )23.6 3411 2813 31.7 5725 1151152511 10.8271028刀开关 HD13BX-200/31HD13BX-200/31200/31HD13BX-200/31200/31HD13BX-200/31HD13BX-200/31断路器 1 1 Z20J-L Z20J-LZ20J-IZ20J- LZ20J-IZ20J- DZ 20J- DZ20J- DZ20J- DZ20J-DZ2UJ- --- 'DZ2UJ- --- DZ2UJ- ---00/32A 1 00/40A 100/20A 1 00/32A1 00/20A- 00/20A100/32A00/63A00/20A00/32A200/120A DW15-200/120A 200/120A 100/32A100/32A 100/20A 100/20A100/20A 100/32A 100/20A 100/20A 100/32A 100/20A电流互感器 LMZ1-0.66,100/5LMZ1-0.66,100/5150/5LMZ1-0.66,100/5LMZI-0.66, 150/5 LMZ1-0.66,100/5LMZ1-0.66,100/5弓 出电缆型号截面 y6+1X4 3X 22-1V 10+1X 6322-1 v 4+1X 2.5 3 :6+1X4-2 X4V22-1-4X63〉25+1X 10 3 <6+1X45X 50+1X 253X 50+1X25S X 6+1X4X 4+1X 2.5 3 X 4+1X 2.5 3 X 6+1X4 3X44X6穿管管径G25 G25 G25 G25G15G32 G32G25G25G25 G25 G25 G25G32BT95O9为事故照明切换板,其直流电源用 VV22-1-2X 4电缆引至直流屏。

电气一次主接线图讲解和分析

电气一次主接线图讲解和分析

绘制原则及规范
规范
1
2
图形符号和文字符号应符合国家相关标准和规定。
3
设备编号和标注应符合电力系统命名和编号规则。
绘制原则及规范
图纸幅面和格式应符合国家相关标准 和规定。
图纸的绘制和修改应符合相应的设计 和管理流程。
02
电气一次主接线图类型与特 点
单母线接线图
简单明了
01
单母线接线图是最基本的电气主接线形式,其结构简单,易于
案例二:某发电厂电气一次主接线图优化
01
02
次主 接线图
优化方案
优化后的电气一 效果评估 次主接线图
简要介绍发电厂的规模、 类型及在电力系统中的地 位。
展示发电厂原有的电气一 次主接线图,分析其存在 的问题和不足之处。
提出针对性的优化方案, 包括设备配置、接线方式 、运行方式等方面的改进 。
电气一次主接线图讲解和分 析
目录
• 电气一次主接线图概述 • 电气一次主接线图类型与特点 • 电气一次主接线图分析方法 • 常见故障识别与处理策略 • 实际应用案例解析 • 总结与展望
01
电气一次主接线图概述
定义与作用
定义
电气一次主接线图是用规定的图形和文字符号表示一次电气 设备(如发电机、变压器、断路器、隔离开关、母线、电缆 、输电线路、电抗器、避雷器、熔断器、电流互感器、电压 互感器等)相互连接关系的电路图。
运行与维护
阐述工业园区配电网的运行和维 护要求,包括设备巡视、故障处 理、预防性试验等方面。
工业园区概述
简要介绍工业园区的规模、产业 类型及用电负荷特点。
技术经济分析
对工业园区配电网规划与设计进行 技术经济分析,包括投资成本、运 行成本、经济效益等方面。

电气一次主接线图课件

电气一次主接线图课件
作用
电气一次主接线图是电力系统的重要 组成部分,用于描述电力系统的整体 结构和运行方式,是电力系统设计、 建设和运行的重要依据。
分类与特点
分类
电气一次主接线图可以根据不同的分类标准进行分类,如按照电压等级、接线 方式、设备类型等。
特点
电气一次主接线图具有直观、简明、易懂的特点,能够清晰地展示电力系统的 整体结构和运行方式,便于电力系统的规划、设计、建设和运行管理。
电缆
用于传输电能,通常埋 设在地下或天花板中。
接线端子
用于连接导线,确保导 线的可靠连接。
连接金具
用于固定和连接导线, 确保导线的稳定性和安
全性。
标注与符号
标注
标注是电气一次主接线图的重要 组成部分,用于标识电气设备和 导线的名称、规格和参数等信息 。
符号
符号是电气一次主接线图的另一 种表达方式,用于表示电气设备 和导线的类型、功能和连接方式 等信息。
根据实际需求和运行工况,优化设备选型 ,提高设备的利用率和寿命。
冗余设计
智能化监控
考虑引入适当的冗余设计,提高系统的容 错能力和可用性。
建议引入智能化监控系统,实时监测电气 一次主接线图的运行状态,提高故障响应 速度和系统维护效率。
06
电气一次主接线图的发展趋势与展望
新技术与新设备的应用
数字化技术
制定统一的电气一次主接线图标准,规范设 计、生产和维护流程,提高互换性和兼容性 。
模块化
将电气一次主接线图划分为若干个模块,便 于组装、拆卸和维护,提高工作效率和灵活
性。
智能化与自动化的趋势
智能化
利用人工智能技术对电气一次主接线图进行智能监控、诊断和维护,提高运行效率和安全性。

典型水电站设计cad电气主接线图纸

典型水电站设计cad电气主接线图纸
电站概况:主 要 设 备 表接地变压器装置序号设备名称型号及规格套单位14数量282930121242525262723231913313967134137999710111113413779991341579799697161715181920102098914514989台14隔离开关778MVA 20kV cos =0.9 水轮发电机中性点电流互感器114避雷器励磁变压器(单相)厂用变压器电流互感器电压互感器电压互感器电压互感器电气制动装置主变压器主变压器中性点小电抗装置151614接地开关断路器电流互感器隔ቤተ መጻሕፍቲ ባይዱ开关隔离开关断路器快速接地开关罐式避雷器隔离开关罐式电压互感器瓷套式避雷器高压并联电抗器中性点并联电抗器(单相)/空气套管断路器电流互感器SF6小电抗装置线路阻波器电容式电压互感器30000/1 0.2/0.2/0.2/5P/TPY/TPY单相干式 5000kVAY2.5W1-25/48单相干式 2200kVA(VGS)/2925kVA(ALSTHOM)3P/100VA/开口三角形0.2/45VA / 单相kV30.130.13200.12033P/100VA/开口三角形3P/100VA/单相0.133kV0.13200.2/35VA/单相3P/100VA/单相0.13kV3840MVA 550-2x2.5%/20kV66kV 20 392kvar24kV 12kA63kA3000/1A 0.2/TPY/TPY 5P20/TPY/TPY2000A 63kA2000A 63kA63kA3150A 63kA444kV 电站型3150A 63kA4000A 63kA4000/1A 0.2/TPY/TPY 5P20/TPY/TPY4000A 63kA66kV 500ohm(162kvar)/600ohm(194.4kvar)50Mvar0.15503150VA/150VA/100VA0.2/3P/3P0.133kV0.120W1-444/1065XZZF-3150-1.0/63TYD500/ -0.005H0.15503kV0.1330.13台1816818/2442台台台台台套套台台台424242141414235821台14铁芯666组108组组台2台组12台24台12组4铁芯36支台12套2/2台台3台242424长江三峡水利枢纽工程是具有防洪、发电、航运等综合效益多目标开发的大型水利工程,其大坝位于湖北省宜昌市三斗坪镇,距下游已建成的葛洲坝水利枢纽约40km。MVA\fSimSun|b0|i0|c134|p49三峡水电站汛期在电力系通中担任基荷和腰荷,非汛期在电力系通担任峰荷和腰荷,枯水期机组起停频繁。电站以550kV一级电压接入电力系统。电气主接线为:发电机电压侧采用发电机—变压器单元接线,在变压器高压侧装设500kV断路器,两组单元接线组成联合单元,然华中地区550kV550kV243550kV GIS设备56789101113121718192021222320kV发电机电压级设备222625242728发电机中性点设备303129主变压器中性点设备三峡换流站三峡换流站三峡换流站万县万县荆州荆州荆州1212,}高压一倍半接线中有一串为双开关接线;左二电厂为6台机组,500kV出线3回。左一电厂送到重庆市万县和直流换流站,左二电厂送至华中的荆州。

热电厂工程电气主接线CAD图

热电厂工程电气主接线CAD图
电气主接线综合自动化保护、测量、计量配置图WUCA相电压BC相电压有功电度无功电度WhVARhUbcI-I频率HzUaA相电压ccaUUbB相电压C相电压有功功率A相电流VARaA无功功率abcUAC0SΦbAB相电流功率因素C相电流AB相电压50/550/5Ⅰ-4AH: KYN28-12-18Ⅰ-6AH: KYN28-12-02Ⅰ-5AH: KYN28-12-02/0.2/0.5300/5300/550/550/5Ⅲ-6AH: KYN28-12-02Ⅰ-3AH: KYN28-12-45Ⅲ-2AH: KYN28-12-02Ⅲ-4AH: KYN28-12-02Ⅰ-2AH: KYN28-12-0250/5200/5HY5WS3/0.2/0.550/5Ⅱ-2AH: KYN28-12-02Ⅱ-5AH: KYN28-12-02Ⅲ-8AH: KYN28-12-02Ⅱ-3AH: KYN28-12-45Ⅱ-4AH: KYN28-12-1850/5Ⅱ-6AH: KYN28-12-02HY5WS3SCB9-1250/10.510.5±2×2.5%/0.4KV准人人图计D/Yn11Uk=6%1250KVA 1#厂用变LZZBJ9-10XRNP-10-17/50TMY-40X4LXK-Φ120备用LZZBJ9-1031.5KA0.5/5P20800AJN15-12300/5Ⅱ-8AH: KYN28-12-0210KVⅡ段TMY-3(120X10)TMY-50X5ZN21-12800A31.5KATMY-50X5ZN21-122、 同期点为:发电机出口断路器、10kV母联断路器、110kV线路断路器、主变低压侧断路器、110kV母联断路器。共9点。1、 10kV高压开关柜的外形尺寸为:宽×深×高=1000×2000×2335mm。说 明0.4KVⅡ段(2#炉)0.4KV Ⅲ 段(Ⅲ#炉)负负批程工制专设业责责0.4KV

什么是电气主接线图?

什么是电气主接线图?

什么是电气主接线图?一、什么是电力系统和电力网?答:由各种电压的电力线路将一些发电厂、变电所和电力用户联系起来的发电、输电、变电、配电和用电的整体称为电力系统。

大型电力系统可以是由发电厂联合供电的系统。

通常将电力系统中各级电压的电力线路及其联系的变电所称为电力网。

在我国习惯将电力系统称作电网,电网按电压等级来划分,有10kV电网、110kV电网等;也可按地域来划分,如华东电网、东北电网等。

抵押配电线路的额定电压为380V/220V。

用电设备的额定电压多数是220V和380V;大功率电动机的电压为3kV和6kV;机床照明和矿井安全电压规定为36V。

二、什么是电气主接线图?答:用国家统一规定的电气图形符号、文字符号表示主接线中各电气设备相互连接顺序的图形就是电气主接线图。

电气主接线图一般都用单线图表示,即一根线就代表三相。

但在三相接线不同的局部位置要用三线图表示,例如,较为常见的是接有电流互感器的部位。

三、电气主接线图有何特点?常用典型电气主接线图是指由电力主变压器、母线、各类断路器、隔离闸刀、负荷开关、进出架空线、电力电缆、并联电容器等一次电气设备,按一定的次序连接,汇集和分配电能的电路组合。

它是电气设备的选择、配电装置的确定、安装调试、运行操作、事故分析的重要依据。

四、电气主接线图有哪些类型?变电站的电气主接线图分为有母线和无母线两类结构。

所谓母线,是指汇集和分配电能的导线,又称汇流排。

母线按材料不同,又称为“铜排”、“铝排”。

连接各进出线的母线称为主母线,其余的为分支母线。

母线在电气主接线图中用黑粗线表示。

有无母线及母线的结构,是电气主接线形式的核心问题。

五、电气主接线的基本形式有哪些?变配电所电气主接线的基本形式较多。

应用不同的母线接线方式,可使在变压器数量少的情况下也能向多个用户的馈电线供电,或保证用户的馈电线能从不同的变压器获得供电。

对于中小型工厂的变配电所来说,其主接线大多是采用单母线接线,也有的采用其中两种基本形式的组合。

35kV线变组电气主接线图01

35kV线变组电气主接线图01
35kV进线
1I1
氧化铸避雷器 HY5WZ-51/134J ill级防百 配在线监测仪
35kV电磁式电压互感器〈 两台)
A ‘ B相
m JDZB-35 , 级防污
35/0.22kV容量300\J
bHA
G\,/5-35D/630 E级im

B� C相
配手动操作机构

35kV柱上智能真空断路器 Z\,/32-40.5
氧化铮避雷器 YSWS-17/50J ill级防污
lOkV出线
圃’7陕饵’-10/刷 E甸回i.7/1’副a 撞撞’!GI町i 10.町
小嚣嚣电血阻,0. . 5-甜llt-10 - L1I"Z1-0t.2l0lOJJ1剧/1A
说明: 1、35kV台架变包含:主变压器1台,容量:6300kV及以下J
35/10kV;35kV 、 10kV出线各1 回. 2、台架变电气主接线如本图.
XXXX川 XXXXXXXXXXXXXXX有限川 公司
川一
-H
一川
-u
一叫
XX供电局35千伏配电站
工程|方案::
电气主接线图
回号
附固01
630A 内置CT:[ J/1A10P2Fra bibliotek 20(10)VA
35kVJ容量6300kVA及以下 三相两卷有载调压变压器 〈优先利用闲置物资〉
10kV柱上智能真空断路4 Z\,/32-12
630A 内置CT:[ J/1A 10P10 5-10-15VA 外置1台三相五柱式电压互感器 10/ J3 : 0.38/ J3 输出电压380V (容晕。( VA) )220V (容量300VA) 隔离开关G\,/1-lOD/630 10kV 630A 20kA ffl级防污

电气课件(1、主接线图)PPT课件

电气课件(1、主接线图)PPT课件
预备工作要求
明确下一讲前需要完成的预习任务、阅读材料和思考问题,帮助 学员更好地理解和掌握下一讲的内容。
学习建议与鼓励
针对学员的学习情况和需求,提出合理的学习建议和鼓励,激发 学员的学习兴趣和动力。
THANKS FOR WATCHING
感谢您的观看
电气课件主接线图PPT大纲
目 录
• 主接线图基本概念与重要性 • 主接线图基本符号与绘制规则 • 各类设备在主接线图中表示方法 • 主接线图类型及其应用场景举例 • 主接线图在实际操作中的应用 • 总结回顾与拓展延伸
01 主接线图基本概念与重要 性
主接线图定义及作用
主接线图定义
主接线图又称电气主接线图,是用来 表示电力系统中电气设备的连接方式 、电气设备的配置以及电气设备的保 护和控制方式的图纸。
圈、铁芯和接线端子等部分。
变压器类型
根据用途和电压等级,变压器可分 为电力变压器、配电变压器、自耦 变压器等类型,在图中应明确标注。
特点分析
变压器的主要特点是变换电压和电 流,实现电能的传输和分配。在图 中应突出其变换特性,便于理解。
断路器、隔离开关等设备表示方法
断路器符号
断路器在电气主接线图中用特定的图 形符号表示,包括触点、操作机构和 灭弧装置等部分。
隔离开关符号
隔离开关也用特定的图形符号表示, 与断路器符号相似但有所区别,通常 用于隔离电源或设备。
设备类型
根据用途和电压等级,断路器和隔离 开关可分为多种类型,在图中应明确 标注。
特点分析
断路器和隔离开关的主要特点是接通、 断开或隔离电路。在图中应突出其控 制特性,便于理解。
母线、电缆等线路表示方法
学习主接线图的意义和价值
01
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

变电所中还普遍采用主接线模拟屏(操作图),挂
在主控室内。它模拟出牵引变电所电气设备的实际 运行状态。值班人员根据模拟屏中电气设备的实际 运行状态和调度命令进行操作,操作后更改模拟屏 中电气设备的实际运行状态,使其与实际相符,便 于观察。 学习电气主接线的目的:(1)掌权变电所的结构。 (2)熟悉牵引变电所倒闸作业的内容、原则和安 全操作步骤。(3)了解电气主接线对电气设备的 选择、配电装置的布置、继电保护装置的设置,整 定及主变压器可靠、经济、安全运行由密切关系。 (4)掌握主接线的运行方式,主变压器、馈线断 路器的备用方式。
(5)继电保护及自动化装置:按远动化设计,有人值守,



无人值班。采用了带安全监控的综合自动化系统。 牵引变压器设重瓦斯、纵差动、低电压启动过电流保护,动 作于跳闸;设轻瓦斯、过负荷、过热法预告信号。 馈线设两段距离、一次重合闸、过流速段、高阻保护动作于 跳闸。 并联电容补偿装置设差电压、差电流、过电流、谐波过电流、 失压、过电压保护。 电源进线设备用电源自投装置,主变压器设自投装置。 (6)自用电系统: 交流自用电:变电所设两台三相所用变压器,一台引自本所 27.5母线,另一台引自铁路10Kv电力贯通线。所用变容量为 80KVA。 直流自用电:所内操作电压为直流110V。设带监控装置的 免维护铅酸蓄电池直流电源成套装置。容量为150Ah。
2、平面布置图
平面布置图按比例画出,用以反映配电装置的结构
尺寸、设备内容及电气设备的连接关系,布置状况 等。 以邳州变电所举例说明: 高压侧高压电气设备采用室外中型布置;27.5Kv侧 馈线侧避雷器采用户外布置,其余高压设备均采用 户内布置。设高压室、电容器室及主控室;所内设 独立避雷针,作为直击雷防护;设变压器事故油池; 所区周围设2.7米高的实体围墙。平面布置预留了高 次谐波装置用场地。 牵引变电所生产房屋与辅助房屋合建,二层楼房布 置,一层27.5Kv设高压室、检修室、主控室及值守 房屋、通信机械室等房屋,二层设电容器室、材料 室等。
二、平面布置图
1、高压配电装置
按主接线图,由开关设备、保护电器、测量
电器、母线和必要的辅助设备、辅助电工建 筑物组成的用以接受和分配电能的装置称为 高压配电装置。牵引变电所配电装置一般分 为室内配电装置和室外配电装置。 配电装置的结构及其中电气设备的布置、安 装状况通常采用平面布置图、配置图和断面 图来表示。
电气主接线一般应满足下列要求: (1)保证对牵引负荷和地区负荷供电的可靠性,并力求经


济性。 牵引负荷是国家电力系统的Ⅰ级负荷,它应有独立的双回路 电源供电。独立的双回路电源是指互不影响的两回110(或 220)Kv线路,即:两回110Kv电源线路来自不同的电源点; 来自同一电源点的不同分段母线上。 (2)主接线应简单、清晰、操作方便。 由于接触网事故比较多,检修频繁,牵引变电所的停、送电 操作、倒闸作业较多,故主接线设计的简单清晰,可减少操 作程序,避免误操作。 (3)主接线应运行灵活,检修、维护安全方便。 主接线的任何一个元件检修检修、试验时应很容易退出运行, 并且不影响其他元件的正常工作。 (4)主接线应具有将来发展的可能性。即应考虑远景规划 中增加设备的可能性。 总之,电气主接线应在电路转化、设备检修和事故处理 等情况下,保证向牵引负荷经济、安全、可靠的供电。
第一部分:电气主接线图、 平面布置图、断面图等
一、电气主接线图
1、电气主接线:
牵引变电所(包括开闭所、分区所)的电气主接线
是指由隔离开关、互感器、避雷器、断路器、主变 压器、母线、电缆等高压一次电气设备,按一定顺 序连接的用于表示接受和分配电能的电路。它反映 了牵引变电所的基本结构和功能,在运行中表明电 能的输送和分配关系、一次设备的运行方式,成为 实际运行操作的依据。 表明一次电气设备相互连接关系和工作原理的电气 接线图,称为主接线图。主接线图一般用单线图表 示。单线图是表示三相交流电气装置中一相连接顺 序的图。安装使用的主接线图还应该在主要电气设 备图形旁标注其规格型号。
3、配置图
户内配电装置通常采用配置图来分析配电装
置的布置方案和统计所用的主要电气设备。 即把进出线、断路器、避雷器、变压器等电 气设备合理分配于各配电间隔中,并标出母 线和电气设备在各间隔中的轮廓合和连接关 系。它不要求按比例绘制,这种表示布置关 系的示意图叫做配置图。
4、断面图
断面图用来表示配电装置中所取断面里(如
某配电间隔断面)的设备内容、连接关系和 结构尺寸。按比例绘制,断面图和平面布置 图结合,能够反映整个配电装置的结构尺寸, 便于施工。如照片所示。
5、牵引变电所户内配电装置的结构 与配制原则
27.5Kv主接线中的同一支路的电气设备布置在同一
间隔内。单元间隔采用网栅和钢板制成的小间。间 隔上设置有单元门和断路器配电箱。 单元间隔可单列或双列靠墙布置,双类布置时电源 类间隔如27.5Kv进线、27.5Kv压互(避雷器)、 27.5Kv隔离开关、补偿电容组断路器等放置在一侧, 负荷类间隔如27.5Kv馈线间隔等放置在另一侧,以 方便运行和维护。 高压室内27.5Kv硬母线分相布置,采用支持绝缘子 垂直或水平固定在墙上。并涂漆以分别相别,A相 为黄色,B相为绿色,中性为黑色。
电缆沟设在操作走廊地下,控制电缆经电缆
2、邳州牵引变电所电气主接线举例
(1)引入两路110Kv电源,进线电源设置设、1002分段的跨条。 设置两台三相平衡牵引变压器,一台运行,一台固 定备用,并设置备用电源自投装置。计费采用高压 侧计费方式。 (2)27 .5Kv侧采用单母线隔离开关分段接线形式。 馈线断路器采用固定备用方式。 (3)为改善牵引供电系统的功率因数并吸收部分 高次谐波,两相母线设置并联电容补偿装置。 (4)110Kv进线采用“H”型架构。
相关文档
最新文档