DM8液体密度计

合集下载

密度计使用说明书

密度计使用说明书

1.概述在工业生产中,液体密度是需要测量的重要物理特性,特别在电子厂、化工厂、炼油厂和品加工厂液体密度的测量是必不可少的。

新型DM8振动式密度计具有高可靠性和丰富的操作功能。

仪表包括检出器和变换器,检出器有振动器和RTD(电阻温度计),它输出检出密度信号(频率)和温度信号(电压)到变换器,变换器用微处理器转换从检出器送来的密度值的频率信号并显示,它也能计算参考温度下这些信号的密度并用数字显示。

变换器除了输出模拟传出信号还可输出数字传输信号并提供多种功能。

如——触式校验、自诊断等。

1.1技术标准说明1.1.1测量对象:液体密度测量原理:振动式密度测量±测量量程:密度:0.5~2.0g/cm3温度:-10~100℃检出器与变换器之间距离:2km以下电源:90~132V AC或180~264V AC,50/60HZ消耗功率:20V A特性:重复性:5*10-4g/cm3(对数字输出而言)量程的1%(对模拟输出而言)线行:量程的±0.5%(当量程0.2g/cm3或更小)量程的±1%(当量程0.2~0.5g/cm3)温度特性:±0.5%/±10℃变化。

流量特性:0-5g/min的±0.1%压力特性:±0.0005g/cm3/±1kg/cm3变化粘度误差:0-1500CP的±0.1%1.1.2检出器普通型密度计:VD6D型检出器构造:非防暴防雨构造外壳材料:铝合金铸件外壳颜色:翡翠绿(相当于孟塞尔色度的7.5BG4/1.5)外壳铸衬:烘涂环氧(树脂)重量:约12kg安装:安装在2寸管上(JIS50A)环境温度:-10-50℃振动器材质:不锈钢JIS SOS316或镍测量液体温度:-10-100℃测量液体压力:小于(20kg/C㎡G)2Mpa最大压力:((50kg/C㎡G)5Mpa蒸气拌热:有过程连接:JIS PT 1/4 内螺纹电气连接:JIS PF 3/4内螺纹防火防爆型检出器 VD6DF型检出器构造:JISd2G3防火或FM防火型构造电气连接:JISPF3/4内螺纹或3/4NSM内螺纹(注)除以上防火型构造外,其余的和(1)中普通型说明一样卫生新法型检出器:VD6S型过程连接:用JIS6A(公称直径6mm)管子特殊连接蒸气拌热:没(注):除以上两点之外,其余的和(1)中普通型说明一样1.1.3变换器 DM8C型外壳构造:防尘防雨构造铸寸颜色:前门,相当于孟塞尔色度的2.8GY6.4/0.9外壳:相当于孟塞尔色度的2.8GY3.1/0.5外壳铸衬:烘涂环氧树脂安装:安装在盘面、墙上和JIS50A管重量:约7.5kg环境温度:-10-50℃显示:数字显示,5位LED数字显示显示内容:参考温度下变换后的密度值;测量温度下的密度(g/cm3);测量液体温度(℃)校验液体密度设定值(调用显示);校验液体温度系数设定值*10-5g/cm3/℃(调用显示);输出量程的低限(%)(调用显示);输出量程的高限(g/cm3)(调用显示);参考温度(℃)(调用显示);测量液体温度系数设定值(-1*10-5g/cm3/℃)(调用显示);检出器系数A,B(调用显示);检出器校验系数C,D(调用显示);故障内容显示;模拟输出信号:4-20Ma℃和0~1V℃传送数据;参考温度下变换后的密度;量程:0.05~g/cm3数字输出信号的接口:RS-232C⑴通讯标准异步系统起动位: 1停止位: 2奇偶: 没数据传输:1200位/S传输系统:ASCⅡ,字母长度:8位接线系统:两线制输出⑵输出信号传送内容:测量数据(参考温度下变换后的密度(g/cm3);测量温度下的密度(g/cm3);测量液体温度(℃);校验状态(校验起动,误差编号,校验结束);故障报警(误差编号).信号电平输出电压:ON,9±3V,OFF,-9±3V输出阻抗:300欧姆输出格式测量数据#*.**** **** ***.*CRLF(注):数据按照参考温度下变换后的密度,测量温度下密度,测量液体温度的顺序输出.在校验或维护方式时输出保存数据(输入(出)方式时的正当值).而校验或维护方式转换后,保存的数据马上被解除.校验状态#CALIBRTION START CRLF(注):校验时无数据输出,然而,当发生参数误差时,输出就变成如下:#ERROR *CRLF(*:5.0r6)#CALIBRATION END CRLF故障报警#ERROR *ERROR *......CRLF( 注):当发生多种误差时,输出相应的各个误差编号.例:#ERROR-1 ERROR 3CRLF异常状态的触点输出:常闲单点触点(16)最大电压:220V.DC,250V.AC最大电流:2A(电阻负荷)最大触点电压:60W.检出器异常的内容:检出器和变换器异常.输出信号的保存:当处于校验(CAL)和维护(MAIT)方式时被保存,如出现故障状态,减少10%数据被保存.温度系数设定范围:0~0.002g/cm3/℃校验方法:通过设定液体密度的一触式校验.空气吹扫连接:JIS PT1/8,PT1/4内螺纹或1/4NPT内螺纹(供选择)电缆入口Ⅱ:27㎜直径,五孔,盖有四个相当于JISA15的防水塞子,一个相当于JISA20塑料防水塞子(附件).电源:90~132VAC或180~264VAC,50/60HZ1.1.4 专用电缆:DM8W型型号:六芯双屏蔽电缆绝缘:聚乙烯护套:聚氯乙烯绝缘电阻:1000Me/km导线电阻:15.3欧姆/km外径:15.8mm1.1.5 附件注射采样测量液体的注射器 1PC刷子(清洗振动器用) 1PC开启接线箱的六角螺钉扳手 1PC取检出器盖子的六角钢板手 1PC干燥剂 2PC变换器的保险丝 1PC1.2型号和后缀符号1.22防火型检出器1.2.3卫生型检出器1.2.4变换器1.2.5专用电缆1.3外部尺寸1.3.1检出器1.2.3卫生型检出器1.2.4变换器1.2.5专用电缆1.3外部尺寸1.3.1检出器普通防火型图1.4使用防火型、防爆型仪表的注意事项1.4.1 防火型仪表的概述防爆仪表的技术标准符合有关的国际组织的规定。

DM8C 型生产用振动式密度计

DM8C 型生产用振动式密度计
,

,
故 粘滞 性 的影 响 也是 很小 的
内部
DM
S 是 用 微处理 器进 行运算 的 C
(2 )
,
故应 尽 令
充满掖 体 的 截 面均 匀 的 管子 的 横 向振 动 衬 可以 看做 是 其质量 随 被测 液体 的密度 而 变化 的弹性 体 的横 向振动
} 。
可 能 减 少式
A
中参 数的数 目
2
(E 丢失
P RO M )

保存
以 防止 数据 由于 瞬停 等而
, ,
T
,
再经
V

它 们 的 自 由端 用 质 量 远 比 底 盘小 的 连 接器 连 接
fx
和 f 永夯 别 由各 自的 专 用 计 温 度 的计 算 以及 标 准 牢 和
,
起来

这 种音 叉 如 图 中 虚 线 所 示 以 中央 为波 腹

而 振动 器 中的
被测 液 体 由

1
流向
2
,
,
在 谁行奔
D 6 C型 不 同
,

D M S C 型 振动 式 密度计
,
它 与原
,

D
一 全
D孟 )
由于 内装 有微 处 理器
,
提 高
P
高 了 灵 敏 度和 稳定 度 可 靠性
,
不 仅实 现 了 高性 能
。Leabharlann 、A`一
三 以 D圣 一 4一 (
`

D置 )p
l
+
p 〕 D置
:
而且 便 于 用 户 校 准和 维 修

DM8C密度计的安装与应用

DM8C密度计的安装与应用
4 2
第 2期
李天 鹏 : D M 8 C密度计 的安 装与应 用
地与 D C S 连接 , 完全实现 自动在线监测。
Ke y wo r d s :d e n s i t y me t e r ;c o n v e r t e r;d e t e c t o r;v i b r a t i ng t u b e
A b s t r a c t : T h e c o n s t r u c t i o n a n d i n s t a l l a t i o n o f D M8 C d e n s i t y me t e r a r e i n t r o d u c e d .T h e r t e a t me n t
因此通常须 给 阴极 液 补加 一定 的纯水 , 实 际 就 是控 制N a O H 的 浓 度 以保 证 适 量 的 水 迁 移 来 保 护 膜 。
1 密 度计 的构 成
D M 8 C振动式 密度计具 有高 可靠 性 和丰 富 的功 能。密度 计 包 括 检 出 器 和 变 换 器 。检 出 器 由振 动 管、 音叉 压 电 元 件 ( 以维 持 充 满 碱 液 的振 动 管 振
[ 关键词 ]密度计 ; 变换器 ; 检出器 ; 振动管
[ 摘
要] 介绍 D M 8 C 密度计的构成及安装方式 , 并针对应用中高温碱液对其腐蚀 问题提出了处理措施 。
[ 文献标志码 】B [ 文章编号 ]1 0 0 8— 1 3 3 X( 2 0 1 3 ) 0 2- 0 0 4 2一o 2
N a O H的浓度与 电流效率存在一个最 大关 系值 : 随 着N a O H浓度的升高 , 阴极侧的离子浓度增大 , 电流

梅特勒DM系列密度仪操作

梅特勒DM系列密度仪操作

5.1 5.1.1 5.1.2
校正&检验 校正设置 检验设置
5.2 硬件 5.2.1 检测器
5.2.2 进样器 5.2.3 外部仪器
5.2.4 外围设备
5.2.5 传感器
5.3 用户设定
5.3.1 语言 5.3.2 屏幕
5.3.3 5.3.4 5.3.5
声音 快捷键 键盘
5.4 全局设置 5.4.1 系统
T
A
T。垂直方向上的最大位移为振幅 A。
B A
t
已定义容积的测量管: A) 振动器:磁性 B) 探测:光学
每秒内的周期数为频率 f。玻璃管均以各自不同的频率振动:
f = 1 [s-1] T
当玻璃管充满气体或液体时,频率为总质量的函数会发生变化。如果质量增加,频率降低,即 振动周期 T 变长,相应的公式如下:
温度 1:
温度 2: 温度 3: 温度 4:
检测器内的电极,直接位于 U 形管表面上方。此温度显示为状态信息 (检测器温度)。
加热块的温度 (结块温度) (该温度不显示)
参比温度 (该温度不显示)
环境温度 (该温度不显示)
下图显示模块大致结构:
41
6.1.4.13检验
41
6.1.4.14说明
41
6.1.4.15辅助值
41
6.1.4.16条件
42
6.1.5 标样数据
42
6.1.6 公式
42
6.1.6.1 公式编辑器
42
6.1.6.2 数学函数和算符
43
6.1.6.3 公式句法
43
6.1.7 方法句法
44
6.1.8 METTLER TOLEDO 方法

高精度液体数显密度计安全操作及保养规程

高精度液体数显密度计安全操作及保养规程

高精度液体数显密度计安全操作及保养规程1. 引言高精度液体数显密度计是一种常见的实验室仪器,用于测量液体的密度。

为了保证仪器的正常运行和使用者的安全,使用前需要了解安全操作规程和保养要点。

本文档将介绍高精度液体数显密度计的安全操作和保养规程。

2. 安全操作规程2.1 仪器准备在使用高精度液体数显密度计之前,需要进行一些准备工作:•确保仪器放置在稳定的工作台上,并且没有杂物阻挡;•检查电源线是否连接牢固,没有损坏;•检查液体显示屏、键盘和控制面板是否正常工作;•确保仪器内部的清洁程度,特别是测量池区域。

2.2 仪器操作在正式使用高精度液体数显密度计进行测量之前,请按照以下步骤操作:1.打开仪器电源开关,并等待仪器自检完成;2.使用清洁的毛巾或纸巾轻轻擦拭测量池的表面,确保表面干净;3.打开液体密度计软件,设置所需的测量参数;4.将待测液体缓慢倒入测量池中,并确保液体不溢出;5.等待仪器测量完成,并记录测量结果。

2.3注意事项在使用高精度液体数显密度计的过程中,需要注意以下事项:•避免使用有腐蚀性的液体进行测量,以免损坏仪器;•严禁在测量池中倒入过热的液体,以免烫伤;•注意避免意外碰撞仪器,以免损坏仪器;•在清洁仪器表面时,避免使用粗糙的物品,以免刮伤表面。

3. 保养规程为了保证高精度液体数显密度计的长期使用和准确性,以下是一些建议的保养事项:3.1 定期清洁定期清洁是保养仪器的重要环节,可以采用以下步骤:1.关闭仪器电源,并断开电源线;2.使用湿布或纸巾轻轻擦拭仪器外表面和测量池区域;3.注意不要使用酒精或有机溶剂,以免损伤仪器表面;4.清洁完毕后,等待仪器完全干燥后再次使用。

3.2 定期校准定期校准可以保证仪器的准确性,建议每月进行一次校准。

具体步骤如下:1.准备校准液体,确保其浓度和温度稳定;2.打开液体密度计软件,进入校准模式;3.将校准液体倒入测量池中,并等待仪器完成校准;4.检查校准结果,如有偏差,可以进行校准参数修正。

密度的测定方法

密度的测定方法

液体密度计中文名称:液体密度计英文名称:liquid densitometer定义:测定液体密度的仪器。

常有振动式密度计、放射性同位素密度计、浮力式密度计、静压式密度计、重力式密度计、声速式密度计等。

应用学科:机械工程(一级学科);分析仪器(二级学科);物性分析仪器-物性分析仪器仪器和附件(三级学科)液体密度计液体密度计是工程常用的原稿测量仪器。

液体密度计是测量黑白原稿的灰度值和测量连续调或网点值的光电测量仪器。

密度计分为透射式密度计和反射式密度计两种。

液体密度计在物理实验中使用的液体密度计,是一种测量液体密度的仪器。

液体密度计是根据物体浮在液体中所受的浮力等于重力的原理制造与工作的。

简介在密度计之前称比重计的。

在概念上,密度与比重具有相似的物理意义,即描述某个物体单位体积内所含的物质量。

如果某个物体体积为v,其质量为m,重力加速度为g(=0.98米/秒平方),那么这个物体的重量为mg。

此时,这个物体的密度为m/v,比重则为mg/v。

显然,密度与比重之间在数值上只相差一个重力加速度g。

早前我们用比重概念,现在我们只用密度概念。

由于物体有固体、气体和液体三种基本形态,所以密度计也有对应的种类。

液体密度计是用来测量液体密度的。

液体密度计是采用振筒式密度传感器的原理进行液体密度测试的。

将待测液体泵入谐振筒传感器后,由单片机进行测量处理,快速直接,而且灵敏度高。

该密度计可广泛用于各种液体密度的测量,且配合不同的浓度转换软件,还能直接读出相应液体的浓度值或比重,如酒精,通过单片机软件的处理,可直接读出体积浓度数据,测试更为简便。

该仪器适用于测量化各种学试剂(氢氟酸除外)、液体食品饮料(含碳酸的要先消除气泡)、石油液体产品及其他各种化工液体产品的密度。

不需要熟练的分析人员,不依赖于测量环境,是现场安全测量液体的密度及溶液浓度的最佳工具。

种类常用的液体密度计和比重计有浮子式密度计、静压式密度计、振动式密度计和放射性同位素密度计。

DM8型振动式液体密度计——灵敏高度、稳定可靠、便于使用

DM8型振动式液体密度计——灵敏高度、稳定可靠、便于使用

DM8型振动式液体密度计——灵敏高度、稳定可靠、便于使

佚名
【期刊名称】《工业仪表与自动化装置》
【年(卷),期】1988(000)001
【摘要】密度是一种基本物理量,在一切工业过程中,几乎都是十分重要的信息。

如果使用具有高灵敏度和高稳定性的密度计,不仅能够使以往由于没有合适的在线分析仪而只能凭借人的感官进行的操作实现自动化,而且可以省力、节能、节省资源,并进一步提高和稳定产品质量。

为了满足上述需要,横河电视曾于1967年着手开发并研制成功了VD6型高灵敏度、高稳定性的振动式液体密度计,其作用原理是,当液体流过由中空管道构成的振子液体密度
【总页数】1页(P62-62)
【正文语种】中文
【中图分类】G6
【相关文献】
1.非正态分布参数的压杆稳定可靠性灵敏度设计 [J], 贺向东;张义民;闻邦椿
2.压杆稳定可靠性灵敏度设计 [J], 贺向东;张义民;闻邦椿
3.钢管混凝土拱面外稳定的可靠度与灵敏度分析 [J], 蒋伟;吕大刚
4.万家寨水利枢纽大坝深层抗滑稳定可靠度灵敏分析 [J], 李振富;沈怀至
5.通风系统可靠性稳定性及灵敏性数学模型 [J], 贾进章;刘剑;倪景峰
因版权原因,仅展示原文概要,查看原文内容请购买。

液体密度计的操作规程

液体密度计的操作规程

液体密度计的操作规程1. 引言液体密度计是一种广泛应用于实验室和工业生产中的仪器,用于测量液体的密度。

本文档旨在提供液体密度计的操作规程,以确保使用者正确、安全地操作该仪器。

2. 仪器准备在操作液体密度计之前,需要进行一系列的仪器准备工作。

首先,检查仪器的外观是否完好,并确认仪器处于稳定的工作状态。

其次,确保所使用的液体密度计的测量范围适合待测液体的密度。

最后,将液体密度计放置在水平台面上,确保仪器处于稳定的位置。

3. 测量流程3.1 校准液体密度计在进行实际测量之前,需要先校准液体密度计,以确保测量结果的准确性。

校准液体密度计的方法因不同型号而异,建议参考仪器的使用手册或相关的标准操作流程进行校准。

一般而言,校准过程包括清洗试样槽、选择校准物质、测量校准物质的密度等步骤。

3.2 准备待测液体样品在测量待测液体样品之前,需要准备样品并遵守以下步骤: 1. 清洁液体密度计:用纯水或适当的清洁剂清洁密度计的试样槽,以确保不会产生干扰或污染。

2. 清洗待测液体容器:确保待测液体容器内部干净,并避免任何杂质对测量结果的影响。

3. 准备足够的待测液体:液体样品的数量应足够填满密度计的试样槽,以确保测量的准确性和稳定性。

3.3 开始测量按照以下步骤进行液体密度测量: 1. 打开液体密度计的电源,并确保仪器处于正常工作状态。

2. 将清洁的待测液体容器放置在密度计的试样槽中,并轻轻旋紧容器的盖子,以保证试样不会外溢。

3. 进行测量前的预热:根据具体仪器的要求,等待一段预定时间,以使液体温度与仪器达到平衡。

4. 开始测量:按下仪器上的测量按钮,液体密度计将自动测量并显示液体的密度值。

5. 记录测量结果:将测量结果记录下来,并确保记录的数据准确无误。

6. 清洁测量容器:测量完成后,将待测液体容器和试样槽彻底清洗,并确保没有任何杂质残留。

4. 维护与保养为了确保液体密度计的长期正常工作,需要进行定期的维护与保养工作。

Omega DCB83 液体密度和浓度测试仪说明书

Omega DCB83 液体密度和浓度测试仪说明书

e-mail:**************For latest product manuals:Shop online at ®User’s GuideDCB83Liquid Density andConcentration TesterMADE IN TAIWANwww.***********************Servicing North America:U.S.A.:Omega Engineering, Inc., One Omega Drive, P.O. Box 4047S tamford, CT 06907-0047 USAToll-Free: 1-800-826-6342 (USA & Canada only)Customer Service: 1-800-622-2378 (USA & Canada only)Engineering Service: 1-800-872-9436 (USA & Canada only)Tel: (203) 359-1660 Fax: (203) 359-7700e-mail:**************For Other Locations Visit /worldwideThe information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.Electronic Densimeter(Liquid Density & Concentration Tester)DCB83Instruction ManualBefore using this instrument, please read the instructions carefully. Please keep manual in a ready reference.A. Density calculation: According to the buoyancy method of Archimedean principle,the unknown liquid density can be calculated by using the standard glass weight. The weight species can be chosen according to the liquid property.B. Concentration calculation: According to the transformation formula of density andconcentration (y= a + bx), y is concentration, x is density, and it can be calculated by using back-stepping linear.1.Accessories:1. Liquid specialized frame2. Glass weight3. Hook4. 50 cc beaker5. Support plate6. Main-body7. Windshield (optional) 8. AC adaptor 9. Thermometer 10. Calibration weight2. The installation of DCB83When installing DCB83, it should avoid: ¨ The vibration place ≠ Static electricity Æ Direct sunshine Ø Electromagnetic wave∞The places where is too wet or too high temperatureInstallation Steps:¨After placing the DCB83 body in the windshield, adjust the 4 feet of main-body, adjust the level bubble on the after side of the main-body to the center.≠Put the liquid specialized frame on the weighing scale, and using the four feet getting stuck the frame.ÆEmbedding the 4 round feet of the black support plate into the 4 round hole of the main-body.ØPlace the two pieces removable doors of the windshield on the top and the front, then the installation finishes.3. Warming up:It takes about 10 minutes for an electric circuit to become stable after plugged in and turn on the power.4. Calibration:When using the direct reading electronic densimeter DCB83, the density of the sample is on the basis of the weight calculation. Accurate measurement result is based on measuring the gravity accurately. It is recommended to calibrate with 100g weight on the following occasions.when the balance is first used when the balance has been moved when the location of surroundings are changed as a periodical adjustment4.1. How to calibrate:Plug in and preheat for 30 minutes (for cold northern regions) Display show0.00When the balance is under the state of weighing mode, press the keyZERO and hold it.CAL 300It means entering calibration procedure when it displays CAL, It willdisplay mutual flashing between CAL and 300A: Put the 100g calibration weight on the sensor when the screenCAL 100 flickers, the balance will detect weight automatically andcalibrate it simultaneously.B: The calibration finishes when the screen displays –END-100.00C Pick up the weight and back to the under-test mode 0.000※Notice:After calibration, it should be calibrated again if the machine is moved to other places.5. Setting the weight of glass weight, the high limit and low limit of density When the screen displays 0.00, press the key F and hold it to enter parameter setting, click the key F to enter the next parameter setting, the parameter setting procedure is A2d SG Hi SG Lo E1E2, press PRINTto enter the mode to modify the parameter, the methods of data-modifying are as follows:1. Increase the value2. Press PRINT and hold it to give up modifying1. Digital shift2. Press Fand hold it to go off the options1. Confirm changes5.1 Setting the weight of glass weight A2: weighing the glass weight first, and then input the weight of glass weight to A2Method1:Under the 0.00g measuring state of liquid mode, put the hook on the liquid specific frame, press ZERO to re-zero; then catch on the glass weight by using the hook, press MOMOERY key after stable, the screen will display SET A2, it indicates that the glass weight has been memorized to A2.Method2Press the key F and hold it when the screen shows 0.00, when it shows A2, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set the weight of glass weight; after setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.5.2 Setting the density of glass weight:After setting the weight of glass weight, when it shows d , press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set the density of glass weight; If the density of glass weight is 2.226, input d 2.226 , press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.5.3 The function of high limit and low limit setting: (Setting of SG Hi, SG Lo)DCB83 has the function of high limit and low limit, the range of high limit and low limit can be set freely. If the density of the sample is higher than the high limit, the screen will display Hi; if lower than the low limit, it will show Lo; If the density is between the high limit and low limit, the screen will show OK.Notice: When the setting of high limit and low limit is 00.000, the function is closed.5.3.1 The density setting of high limit: SG HiThe steps are as follows:Enter setting mode, press F for several times until the screen displays the density setting of high limit SG Hi, press PRINT to enter the option; then press PRINT again to modify the value, and press F to shift; At the moment press PRINT and F to set the value needed, press the key MEMORY to back to the next setting mode after finishing setting, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.5.3.2 The density setting of low limit: SG LoThe steps are as follows:Enter setting mode, press F for several times until the screen displays the density setting of low limit SG Lo, press PRINT to enter the option, then press PRINT again to modify the value, and press F to shift; At the moment using PRINT and F setting the value needed, press the key MEMORY to memorize and back to the next setting mode after finishing the setting, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.5.4 Setting E1, E2 for testing concentrationAccording to the transformation formula of density and concentration (y= a + bx), y is concentration, x is density, and it can be calculated by using back-stepping linear. For example as follows:Conc.(%) Den.(g/cm3) at 20°C Conc.(%) Den.(g/cm3) at 20°C10.0 0.9820 10.6 0.984210.1 0.9824 10.7 0.984510.2 0.9827 10.8 0.984910.3 0.9831 10.9 0.985210.4 0.9835 11.0 0.985510.5 0.9838According to the data as above and according to the transformation formula y = a + bx, and by using the back-stepping linear of commercial software, we can get the formula y = 283.21 x – 268.12. Thus, the parameter of E1 (-268.12) and E2 (283.21) can be set.5.4.1 E1 Setting:Entering setting procedure, press F for several times until the screen shows E1, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set E1, after finishing setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.5.4.2 E2 Setting:Entering setting procedure, press F for several times until the screen shows E2, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set E2, after finishing setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state.Note: If E1 or E2 is negative value, please note to input a minus sign (-) before the value.Notes:The machine should be kept clean, it needs to be cleaned if the liquid spills out. Please be careful when measuring the explosive or high volatile liquid, because the liquid will be harmful to human body and the machine.6. The operation steps:¨ Pour the 50ml liquid sample into the beaker ≠ Put the standard glass weight whose weight has been memorized into the liquidÆ Put the beaker on the center of the supportplate.Ø Hang the hook on the center of the liquid specific frame∞ Press RE-ZEROto deduct the weight of the hook± Use the hook catching on the standard glass weight, it will display the weight of glass weight in measuring liquidMake sure the measuring liquid is higher than glass weight, and the glass weight can not touch the beaker.≤ After stable, press MEMORY, it will calculate the liquid density value.≥ The screen will display the liquid density value If E1, E2 has been set, concentration will be showed by pressing F¥ If another sample needs to be measured, pressMEMORYto back to the under test state 0.00g.µ If need to measuring again, please note as follows:After cleaning the hook and the glass weight, use another measuring liquid.7. Operating Notes¨Electronic densimeter belongs to precise electronic balance, please assign specific person to be responsible for management and operating.≠If water and other liquid spill out from the container carelessly during measuring, notify the director timely, or it will delay the repair time.ÆMake sure if the machine is at the condition of being immersed or having any fault, before going off duty everyday, it should be checked by director to make sure the screen can show 0.00g , if displays 88888 , it means the machine has broken down. ØHow to do if the body is flooded?Cut off the power first and turn over the body, dry it. Notify the professionalmaintenance staff of sellers to check and maintain it. Do not dismantle it by yourself, or it will damage load cells.8. Maintenance¨DCB83 can not measure objects over 300g, and it should avoid loading the sample over 300g during the process of installation or operating.≠The surface of the machine must be cleaned by dry cloth, please avoid the accumulation of dust.ÆRemove the sink if the machine is non-use for a long time.ØThe machine should avoid crash squeeze and damp, if non-use for a long time, remove the power supply and cover it with dust cover.WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER W ARRANTIES OR REPRESENTATIONS OF ANY KIND W HATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED W ARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1. P urchase Order number under which the product was PURCHASED,2. M odel and serial number of the product under warranty, and3. Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETU RNING ANY PRODU CT(S) TO OMEGA, PU RCHASER MU ST OBTAIN AN AU THORIZED RETU RN (AR) NU MBER FROM OMEGA’S CU STOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.Where Do I Find Everything I Need forProcess Measurement and Control?OMEGA…Of Course!Shop online at smTEMPERATUREM U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & AssembliesM U Wire: Thermocouple, RTD & ThermistorM U Calibrators & Ice Point ReferencesM U Recorders, Controllers & Process MonitorsM U Infrared PyrometersPRESSURE, STRAIN AND FORCEM U Transducers & Strain GagesM U Load Cells & Pressure GagesM U Displacement TransducersM U Instrumentation & AccessoriesFLOW/LEVELM U Rotameters, Gas Mass Flowmeters & Flow ComputersM U Air Velocity IndicatorsM U Turbine/Paddlewheel SystemsM U Totalizers & Batch ControllerspH/CONDUCTIVITYM U pH Electrodes, Testers & AccessoriesM U Benchtop/Laboratory MetersM U Controllers, Calibrators, Simulators & PumpsM U Industrial pH & Conductivity EquipmentDATA ACQUISITIONM U Data Acquisition & Engineering SoftwareM U Communications-Based Acquisition SystemsM U Plug-in Cards for Apple, IBM & CompatiblesM U Data Logging SystemsM U Recorders, Printers & PlottersHEATERSM U Heating CableM U Cartridge & Strip HeatersM U Immersion & Band HeatersM U Flexible HeatersM U Laboratory HeatersENVIRONMENTALMONITORING AND CONTROLM U Metering & Control InstrumentationM U RefractometersM U Pumps & TubingM U Air, Soil & Water MonitorsM U Industrial Water & Wastewater TreatmentM U pH, Conductivity & Dissolved Oxygen InstrumentsM5366/1213。

液体密度的测量方法

液体密度的测量方法

液体密度的测量方法液体密度的测量方法湖北省广水市余店初级中学湖北省广水市余店初级中学 邢大义邢大义液体密度在工农业生产及日常生活中有很大用途,为了使学生更好地掌握液体密度的测量方法,培养学生发散思维的能力,探讨“如何测量液体密度的方法”,我现将它们进行了归纳总结出来,供同学们学习借鉴,以提高学生思考解决问题的能力。

归纳总结出来,供同学们学习借鉴,以提高学生思考解决问题的能力。

一、通常测量液体密度的方法天平和量筒测量方法:天平和量筒测量方法:需要的器材:天平、量筒、烧杯、被测密度的液体。

需要的器材:天平、量筒、烧杯、被测密度的液体。

测量液体密度的方法:①用天平测量烧杯和液体的总质量为m 1;②将部分液体倒入量筒中,测出其体积为V ;③用天平测量剩余液体和烧杯的质量m 2;④则液体的密度为:ρ液=(m 1-m 2)/V /V。

二、缺失器材测量液体密度的方法天平测量方法:天平测量方法:需要的器材:天平、水、烧杯、被测密度的液体。

需要的器材:天平、水、烧杯、被测密度的液体。

测量液体密度的方法:①用天平测量空烧杯质量为m 0;②烧杯中装满水的质量m 1;③烧杯中装满被测液体的质量m 2;④则液体的密度为:。

量筒测量方法:量筒测量方法:需要的器材:量筒、等臂支架、两个相同的小桶、水、细线、被测密度的液体。

需要的器材:量筒、等臂支架、两个相同的小桶、水、细线、被测密度的液体。

测量液体密度的方法:①将两个相同的小桶分别放在等臂支架的两端;②先将适量的被测液体倒入一边的小桶中;将水慢慢加入另一端的小桶中,使支架的两端平衡为止(如图1所示);③将小桶中的液体和水分别倒入量筒中,测得液体和水的体积分别为:V V1、V2;④所示);③将小桶中的液体和水分别倒入量筒中,测得液体和水的体积分别为:则液体的密度为:。

三、弹簧测力计测量方法弹簧秤测量法:弹簧秤测量法:需要的器材:弹簧测量计、小桶、水、细线、被测密度的液体。

需要的器材:弹簧测量计、小桶、水、细线、被测密度的液体。

DM8C型生产用振动式密度计

DM8C型生产用振动式密度计

DM8C型生产用振动式密度计
桂英明
【期刊名称】《国外计量》
【年(卷),期】1989(000)004
【摘要】一、前言密度是了解物质的性质或组成的基本物理量。

通常在生产流程中的液体密度测量,可以使用浮子式密度计、差压式密度计、重量式密度计和放射性射线透过式密度计等。

振动式密度计利用管子横向自由振动频率是其内部充满的液体的密度的函数。

【总页数】4页(P38-40,27)
【作者】桂英明
【作者单位】无
【正文语种】中文
【中图分类】TH715.2
【相关文献】
1.振动式直管段密度计在选矿工艺中的应用 [J], 曹永强;时大卫;冯剑
2.DM8C 型生产用振动式密度计 [J], 桂英明;吴风
3.DM8型振动式液体密度计——灵敏高度、稳定可靠、便于使用 [J],
4.DM8C型密度计在离子膜法烧碱装置的应用 [J], 王志军;钟丽娟
5.单直管振动式流体密度计性能实验研究 [J], 吕发;张小章
因版权原因,仅展示原文概要,查看原文内容请购买。

DM8 横河

DM8 横河

温度计范围
-T100…………… -T150……………
………………… …………………
*A……………… …………………
可选规格
/ST……………
(注)如果需要蒸汽跟踪器,需选择隔膜压力计。
JPI:日本石油协会标准。
技术规格 取样系统 PT1/2 阴螺纹 JIS 10K 15RF 法兰 JIS 20K 15RF 法兰 ANSI 150 1bs 1/2RF 法兰 ANSI 300 1bs 1/2RF 法兰 JPI 150 1bs 1/2RF 法兰 JPI 300 1bs 1/2RF 法兰 1/2 英寸焊接支架 0~1MPaG{0~10kgf/cm2} 0~2MPaG{0~20kgf/cm2} 隔膜压力计 0~1MPaG{0~10kgf/cm2} 隔膜压力计 0~2MPaG{0~20kgf/cm2} 0~100℃ 0~150℃
(g/㎝ 3)值
测量温度下的密度(g/㎝ 3) 测量液体温度(℃) 设置校正液体的密度值(g/㎝ 3)(需要时才调出 数据进行显示) 校正液的温度系数设置值(×10-5 g/㎝ 3/℃)(需 要时才调出数据进行显示) 输出信号设置值(%)(需要时才调出数据进行 显示) 输出量程下限设置(g/㎝ 3)(需要时才调出数据 进行显示) 参比温度(中心温度)设置值(℃)(需要时才 调出数据进行显示) 测量液体的温度系数设置值(×10-5 g/㎝ 3/℃) (需要时才调出数据进行显示) 故障内容显示 输出信号: 模拟输出:4~20mA DC(负载电阻不大于 500 Ω),及 0~1V DC(负载电阻≥250Ω),隔离输
不锈钢 JIS SUS316 BV :球阀,不锈钢 JIS SUS316 NV :针形阀,不锈钢 JIS SUS316 DD :密度计探头 注:本取样系统正常情况下不能用于食品。如果

液体密度计的使用场景

液体密度计的使用场景

液体密度计的使用场景
液体密度计的使用场景:
1.化工产品:在有机物方面,如石油工业的中间产品和最终产品的质量管理和分级,必须使用密度计。

在无机物方面,重化工业产品的纯度管理和浓度管理也需要密度计。

2.水酒饮品:各种饮料,如牛奶、奶制品、软饮料、碳酸饮料、果汁饮料以及啤酒、清酒、洋酒、白兰地、果酒、烧酒等酒类产品,在过程管理和阶段检验时使用密度值或白利糖度值进行质量控制。

3.电机用品:在此类产品的制造过程中,必须使用电镀液、焊油等,并使用密度计将这些液体的浓度保持在一定范围内,这样才能生产出好的产品。

4.油脂:测量植物油、动物油和其他脂肪的密度或比重,作为质量管理的数据。

5.药品:对于药物制剂标准,必须衡量药物的密度和质量,作为质量管理的数据和研发的指标。

液体密度计是一种重要的测量工具,可以用来测量液体的密度,从而帮助人们更好地了解液体的特性。

测量液体密度的方法

测量液体密度的方法

测量液体密度的方法测量液体密度是化学实验中常见的操作,它对于确定物质的性质和成分具有重要意义。

下面将介绍几种测量液体密度的方法,希望对大家有所帮助。

首先,最常见的方法是使用密度计。

密度计是一种专门用来测量液体密度的仪器,它通常由玻璃制成,有一个细长的颈部和一个较大的底部。

使用密度计的方法很简单,首先将密度计放入待测液体中,等待密度计停止摆动后,读取刻度即可得到液体的密度值。

这种方法简单易行,且测量结果准确可靠。

其次,还可以利用比重瓶来测量液体密度。

比重瓶是一种玻璃容器,通常有两个标有刻度的塞子。

使用比重瓶进行测量时,首先要将比重瓶干燥并称重,然后将待测液体倒入比重瓶中,插上塞子并摇匀,再次称重。

通过比较两次称重的差值,就可以计算出液体的密度。

这种方法对于一些不适合用密度计测量的液体也能够得到准确的密度值。

此外,还可以利用浮力法来测量液体密度。

这种方法是利用物体在液体中受到的浮力与其重力相平衡的原理来确定液体的密度。

具体操作时,首先将一个密度已知的物体(如金属块)悬挂在弹簧秤上,浸入待测液体中,记录物体在液体中受到的浮力。

通过测量浮力和物体的重力,就可以计算出液体的密度。

这种方法适用于一些特殊情况,如测量浓度较高的盐水等。

最后,还可以利用声速法来测量液体密度。

声速法是通过测量声波在液体中传播的速度来确定液体的密度。

具体操作时,首先利用声波发生器在液体中产生声波,然后利用声波接收器测量声波在液体中的传播速度,通过速度和液体的声学参数,就可以计算出液体的密度。

这种方法适用于一些特殊的液体,如高温、高压下的液体。

总之,测量液体密度的方法有很多种,每种方法都有其适用的情况。

在实际操作中,可以根据具体情况选择合适的方法进行测量,以确保得到准确可靠的结果。

希望本文介绍的方法对大家有所帮助。

横河DM8C密度计校正方法

横河DM8C密度计校正方法

(1)(2)(3)(4)按下面的公式计算温度补偿系数:温度补偿系数(x10-5 g/cm3/degC)注释:D -5 : 密度 (测量点的温度 - 5degC)D +5 : 密度 (测量点的温度 + 5degC)(5)例)Mode SW:CAL Function 3: 1.2839[g/cm 3]Function 4:87.0[℃]Function 5:068[x10-5g/cm 3/℃]6).(7).(8).(9).10).10密度计(横河)的校正方法仅在(初次)将[MODE]开关切换到[MAINT]模式,请按下FUNCTION分别选择 6, 7, 8, 9将比重的下限值、上限值、基本温度、温度系数分别输入到其中。

请在NV3处取样,并分析密度。

关闭(2)中的取样阀的同时,请关闭NV1・NV2阀门。

(为保持取样液的状态)将[MODE]开关切换到[DSPL]模式,按下[FUNCTION]键,返回到测定模式。

最后,请确认密度值是否正确显示。

请打开NV1 与 NV2 阀门。

对照附属的密度表,将分析的密度[wt%]换算成87℃时NaOH的比重[g/cm 3]与温度。

选择FUNCTION6按下[SET]键,开始校正。

[CAL-1]停止闪烁时,校正结束。

例) 30.0wt% --> 1.2839[g/cm 3]068 [10-5 g/cm3/℃] 在87℃时将[MODE]开关切换到[CAL]模式、请按下FUNCTION分别选择3, 4, 5将取样液的比重、温度、温度系数分别输入到其中。

=-D -5 - D +5 x 100,000。

dm-820音叉密度计说明书

dm-820音叉密度计说明书

dm-820音叉密度计说明书
摘要:
1.音叉密度计简介
2.dm-820音叉密度计的特点
3.dm-820音叉密度计的使用方法
4.dm-820音叉密度计的维护和保养
5.结论
正文:
1.音叉密度计简介
音叉密度计是一种常用的测量液体密度的仪器,它通过音叉在液体中振动产生的声音频率来计算液体的密度。

这种仪器具有测量准确、操作简便等优点,被广泛应用于化工、石油、医药等领域。

2.dm-820音叉密度计的特点
dm-820音叉密度计是一种智能化的音叉密度计,它具有以下特点:
- 采用高精度的传感器,测量准确;
- 具有自动校准功能,确保测量结果的准确性;
- 具有数据存储和输出功能,方便数据分析和处理;
- 操作简便,易于维护。

3.dm-820音叉密度计的使用方法
使用dm-820音叉密度计测量液体密度的步骤如下:
- 将音叉密度计放入待测液体中,使其完全浸没;
- 按下测量按钮,等待几秒钟,直到测量结果显示在显示屏上;
- 读取显示屏上的测量结果,即为液体的密度。

4.dm-820音叉密度计的维护和保养
为了确保dm-820音叉密度计的正常使用,需要进行定期的维护和保养,包括:
- 定期清洗音叉密度计,确保其清洁;
- 定期检查音叉密度计的传感器,确保其正常工作;
- 避免将音叉密度计暴露在高温、潮湿的环境中,以免影响其性能。

5.结论
dm-820音叉密度计是一种高精度的智能化测量仪器,它具有测量准确、操作简便等优点,被广泛应用于化工、石油、医药等领域。

梅特勒DM系列密度仪操作

梅特勒DM系列密度仪操作
3.3 检测器和温度调节器的结构
要正确测定密度,必须保证测量和温度调节的极高精度。
10
DM40 / DM45 Delta Range / DM 50
密度测定基础
由于无法在不干扰振动测量的情况下,直接在 U 形管中测量样品的温度,因此通过三个不同 位置的热敏电阻来进行温度测量,这三个位置可以得到四个不同的测量温度:
开始分析 从编辑器开始 (方法/产品/系列) 在主界面中开始 通过快捷键开始 通过条形码扫描器开始 通过手持式扫描器开始 通过内置式条形码扫描器开始 通过 ErgoSens 开始 暂停分析 分析流程中的功能错误 功能错误类型:错误产生 功能错误类型:错误并终止 功能错误类型:严重错误
11 任务和在线界面
5.1 5.1.1 5.1.2
校正&检验 校正设置 检验设置
5.2 硬件 5.2.1 检测器
5.2.2 进样器 5.2.3 外部仪器
5.2.4 外围设备
5.2.5 传感器
5.3 用户设定
5.3.1 语言 5.3.2 屏幕
5.3.3 5.3.4 5.3.5
声音 快捷键 键盘
5.4 全局设置 5.4.1 系统
5.6.6 软件升级
DM40 / DM45 Delta Range / DM 50
目录
7
8
9 9 9 10
12 12 12 12 13 13 14
15 15 15 16 16 16 17 18 19 21 21 21 22 22 22 22 22 23 23 23 23 24 25 25 25 26 26 27 27 28 28 29 29 29
数值55表格551辅助值552保养服务56mt服务561导入导出562添加外部检测器563恢复出厂设置564固件565软件升级566目录78999101212121213131415151516161617181921212122222222222323232324252525262627272828292929dm40dm45deltarangedm504硬件固件一览567检测插卡568检测器569校正检验测量的导出5610方法和产品6方法61创建方法611创建方法副本612更改或删除方法613方法功能614标题6141配置6142等待6143样品6144进样6145清洁6146检测器检验6147测量6148温度补偿6149计算61410在线显示61411校正61412检验61413说明61414辅助值61415条件61416标样数据615公式616公式编辑器6161数学函数和算符6162公式句法6163方法句法617mettlertoledo方法618产品62创建产品621方法与产品绑定622产品参数623产品中的计算624系列7结果和统计8统计81信息82数据83手动操作9进样器91操作

横河液体密度计

横河液体密度计

liquid (؋10–5 g/cm3/°C) (displayed on
call)
Output signal set value (%) (displayed on call)
Setting for output range low limit (g/cm3) (displayed
on call)
s Standard Specifications
1. General Specifications Measurement object: Liquid density Measurement principle: Vibration density measurement Measurement range : Density: 0.5 to 2.0 g/cm3 Temperature: –10 to 100 °C Distance between Detector and Converter: Up to 2 km Power supply: 90 to 132 V AC or 180 to 264 V AC, 50/60 Hz Power consumption:20 VA
Setting for output range high limit (g/cm3) (displayed
on call)
Reference temperature (center temperature) set
value (°C) (displayed on call)
Temperature coefficient set value for the measuring
s System Configuration
Model VD6SM Sampling unit

标准密度片dv-8参数

标准密度片dv-8参数

标准密度片dv-8参数
标准密度片DV-8是一种用于测量液体密度和相对密度的仪器。

它通常用于化工、食品、制药和其他行业的质量控制和研发实验室中。

DV-8参数包括以下几个方面:
1. 测量范围,DV-8的测量范围通常指的是它能够测量的液体密度的范围。

这个参数通常以单位g/cm³或kg/m³来表示,不同型号的DV-8可能有不同的测量范围,一般来说,它的测量范围可以覆盖大多数工业液体的密度范围。

2. 精度,精度是衡量DV-8测量结果准确程度的参数,通常以小数点后的位数或百分比误差来表示。

不同的DV-8型号可能具有不同的精度,一般来说,精度越高的仪器通常价格也越昂贵。

3. 温度范围,由于液体密度受温度影响较大,因此DV-8通常会有一个适用的温度范围。

这个参数会告诉用户在什么样的温度范围内可以获得准确的密度测量结果。

4. 测量原理,DV-8的测量原理通常是通过测量液体对射线的吸收或者浮力的变化来计算密度。

不同的测量原理可能适用于不同
类型的液体,用户在选择DV-8时需要根据自己的实际需求来选择合
适的测量原理。

5. 其他特性,DV-8可能还具有其他特性,比如自动温度补偿、数据存储和传输功能、多种单位切换等。

这些特性也是用户选择
DV-8时需要考虑的因素。

综上所述,标准密度片DV-8的参数涵盖了测量范围、精度、温
度范围、测量原理以及其他特性,用户在选择和使用DV-8时需要全
面考虑这些参数,以确保获得准确可靠的密度测量结果。

横河电机DM8液体密度计控制脱脂乳中脂肪含量的应用

横河电机DM8液体密度计控制脱脂乳中脂肪含量的应用

横河电机DM8液体密度计控制脱脂乳中脂肪含量的应用
应用简介为控制脱脂乳中的脂肪含量,进行稳定而精确的密度测量
脱脂乳是指从原料奶中除去奶油后的产品。

除去奶油可以使脱脂乳中的脂肪含量尽可能接近指定范围的下限。

为此,控制奶油和脱脂乳中的脂肪含量十分重要。

奶油和牛奶中的脂肪含量与其密度直接相关,因此可以通过测量密度进行控制。

DM8 振动式液体密度计具有高灵敏度和高可靠性,并可根据需要提供卫生型检测器。

DM8 可以实现高精度控制,且易于维护。

预期效果
确保稳定精确地测量液体密度
降低运行和维护成本
工艺流程
在奶油分离机中,原料奶被分离成较轻的奶油和较重的脱脂乳。

通过杀菌和清洁处理后,奶油用于制造黄油和其他乳制品,而脱脂乳被烘干,制成脱脂奶粉,广泛用于甜食和其他食品中。

通过调节分离机出口处的奶油流量,控制脱脂乳中的脂肪含量。

液体密度分析仪安装在两处: 一个位于奶油流路上,另一个位于脱脂乳流路上。

根据所测密度值,控制奶油节流阀的开度。

应用解决方案
测量系统
卫生型检测器:VD6DS-S3*B
转换器:DM8C-A☐*B。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
箱 相当于 2.0GY/3.1/0.5
重庆横河川仪有限公司 YOKOGAWA SICHUAN
Page 2 of 9 涂层:环氧树酯烤漆 安装:表盘式,墙式或 JIS 50A 管式 空气吹扫连接器:Rc1/8,Rc1/4 或 1/4NPT 阴螺纹可选择 电气连接:五孔,直径 27 ㎜
附四个相当于 JIS A15 的塑料防水塞,一个相当于 JIS A20 的塑料防水塞。 重量:大约 7.5kg
(注 2)如果需要蒸汽伴热管,选择隔膜压力计。
(注 3)如果测量溶液含 NaOH(≤30%),选择选项代码 Ni
重庆横河川仪有限公司
YOKOGAWA SICHUAN
GS 11T03A01-CYS
版本:2007 年 5 月第 3 版
■ 线路连接
Page 4 of 9
■ 外形尺寸
1.探头 ● 普通型和防爆型探头 VD6D 和 VD6DF
单位:㎜
重庆横河川仪有限公司 YOKOGAWA SICHUAN
GS 11T03A01-CYS
版本:2007 年 5 月第 3 版
● 卫生型探头 VD6DS
Page 5 of 9
单位:㎜
重庆横河川仪有限公司 YOKOGAWA SICHUAN
GS 11T03A01-CYS
版本:2007 年 5 月第 3 版
规范 卫生型探头
SUS316 B型
2.变送器
型号 后缀代码
DM8C …………
电源
-A1…… -A2……
*A……
(选项) 空气吹扫
连接
选项 代码 …… …… …… ……
/AP1 /AP2
规范
变送器
90~132V AC,50/60Hz 180~264V AC,50/60Hz
A型 Rc1/4 阴螺纹 1/4NPT 阴螺纹
范围的±1%(当范围大于 0.2 g/cm3)
温度特性:±0.5%/±10℃(补偿测量液体温度和检测器温
度变化的误差)
流动特性:在 0~5 l/min 范围内,±0.1%
压力特性:±0.0005g/cm3/±98kPa{±1kgf/cm2G}
(3)卫生型探头
粘度误差:0~1500cp 范围内, ±0.1%
Rc 1/2 阴螺纹
0
VD6SM-10K-P□□0-T1□0*B
JIS 10K 15 RF 法兰
100
VD6SM-20K-P□□0-T1□0*B
JIS 20K 15 RF 法兰
100
VD6SM-150-P□□0-T1□0*B
ANSI Class 150 1/2 RF 法兰
100
VD6SM-300-P□□0-T1□0*B
■ 标准附件
1 喷水器(注入标准溶液或溶剂)
2 刷洗(清洗探头)
1件
3 端子盒用六角扳手
1件
4 固定盖用六角扳手
1件
5 O 形圈
1袋
6 硅胶
2包
■ 型号及后缀代码
1 .探头
(1)普通型探头
型号
后缀代码
VD6D 振动 材料
………………
-S3…………… -N1……………
*B………
规范 普通型探头
SUS316 镍 B型
(3)VD6S 卫生型探头 流程连接:与 JIS 6A(6 ㎜直径)管的特殊连接。(在支 架内) 接液部材料:与标准型一样 支架:Teflon O-形圈:Viton 蒸汽保温加热器:不提供 除上述项外,技术规范与(1)中普通型探头相同。 温度探测器保护管可拆分。 这些探头不能用在强腐蚀性液体及可能粘附传感器的 溶液。如果确定溶液含泥浆或淤泥,咨询 YOKOGAWA。测量 NaOH 溶液,使用镍振动传感器。
探头结构:非防爆探头,防雨结构 外壳材料:铸铝合金 外壳涂层:环氧树酯 外壳颜色:翡翠绿(相当于 Munsell 7.5BG4/1.5) 接液部材料: 底部:SUS316 振动器:不锈钢 JIS SUS316 或镍(闪金:BAu-4)
重庆横河川仪有限公司 YOKOGAWA SICHUAN
转换器
探头
测量液体温度:-10~100℃ 测量液体压力:不大于 2MpaG 承受压力:4.9MpaG 蒸汽保温加热器:提供 流程连接:Rc1/4{JIS PT1/4}阴螺纹 电气连接:G3/4{JIS PT3/4}阴螺纹 安装:50 ㎜直径{JIS 50A(2 英寸)}管道安装 环境温度:-10~50℃ 重量:大约 12kg
/ST…………… /FN……………
技术规格
振动型密度计取样系统(注 1)
Rc1/2 JIS 10K 15RF 法兰 JIS 20K 15RF 法兰 ANSI Class 150 1/2RF 法兰 ANSI Class 300 1/2RF 法兰 JPI Class 150 1/2RF 法兰 JPI Class 300 1/2RF 法兰 1/2 英寸焊接支架
类型代码
*B………………
选项规格
滤网元件材料
选项代码
…………………
………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… ………………… …………………
■ 系统配置
■ 标准规范
1. 一般规范 测量对象:液体密度 测量原理:振动型密度测量 测量范围:密度;0.5~2.0g/㎝3
温度:-10~100℃ 变送器与探头之间的距离:可达 2km 电源:90~132V AC 或 180~264V AC,50/60Hz 功耗:20VA
2.探头 (1)VD6D 普通型探头
衬垫),/FM 选项的镍 重量:约 80kg 流程条件:
入口温度:0~100℃ 入口压力:0~1MPa 差压:至少 100kPa 流速:1~10 l/min
取样系统图 元件规格
F :过滤器,不锈钢 JIS SUS316(80 目) 元件:SUS316,/FM 选项的镍
PI :压力计,0~1MpaG 或 0~2MPa,SUS316 TI :温度计,0~100℃或 0~150℃,SUS316 FM :流量计,锥形金属管流量计,1~10 l/min,SUS316 BV :球阀,SUS316 NV :针形阀,SUS316 DD :密度计探头
(2)VD6DF 防火型(防爆型)探头 探头结构:JIS d2G3 或 NECⅠ级、1 区、C 和 D 组,防火 型结构 流程连接:Rc1/4 或 1/4NPT 阴螺纹(仅用于 VD6DF-□□ *B/FM) 电气连接:G3/4 或 1/4NPSM 阴螺纹(仅用于 VD6DF-□ □*B/FM) 除上述结构不同外,其余技术规范与(1)中普通型探头 相同
(2)防爆型探头
型号
后缀代码
VD6DF ………………
振动 材料
-S3…………… -N1……………
*B………
/FM
规范
防爆型探头
SUS316 镍
B型 NEC Class1,Division1, Groups C 和 D,防爆型
型号 VD6DS 振动 材料
后缀代码 ………………
-S3…………… *B………
注:本取样系统正常情况下不能用于食品。如果需要应用于食 品行业,请咨询 YOKOGAWA。
■ 特性
(探头与变送器组合后的特性) 重现性:5×10-4g/cm3
版本:2007 年 5 月第 3 版
Page 3 of 9
线性度:范围的±0.5%(当范围不大于 0.2 g/cm3)
0~1MPa 0~2MPa 隔膜压力计 隔膜压力计
0~100℃ 0~150℃ B型
0~1MPa 0~2MPa
蒸汽保温加热器(注 2) Ni(注 3)
(注 1)VD6SM 取样单元不包括探头。单独定购 VD6D 或 VD6DF 探头。
对于密度计取样系统,也同样需要 DM8C 转换器和专用电缆 DM8W.
2.变送器 DM8C
Page 6 of 9
单位:㎜
3.专用电缆
密度探头
密度转换器
单位:㎜
重庆横河川仪有限公司 YOKOGAWA SICHUAN
GS 11T03A01-CYS
版本:2007 年 5 月第 3 版
4.取样系统 VD6SM
Page 7 of 9
型号和代码
连接类型
L
VD6SM-JPT-P□□0-T1□0*B
-10K………………………
-20K………………………
管道
-150………………………
连接
-300………………………
-151………………………
-301………………………
-WST……………………
-PG10………………
压力计范围
-PG20……………… -PK10………………
-PK20………………
温度计范围
-T100…………… -T150……………
GS 11T03A01-C
版本:2007 年 5 月第 3 版
3.DM8C 型变送器 显示:数字显示,五位 LED 数字 显示内容:转换为参比温度下的密度(g/㎝3)值
(中心温度) 测量温度下的密度(g/㎝3) 测量液体温度(℃) 设置校正液体的密度值(g/㎝3)(需要时才调出数据进 行显示) 校正液的温度系数设置值(×10-5 g/㎝3/℃)(需要时才 调出数据进行显示) 输出信号设置值(%)(需要时才调出数据进行显示) 输出量程下限设置(g/㎝3)(需要时才调出数据进行显 示) 参比温度(中心温度)设置值(℃)(需要时才调出数据 进行显示) 测量液体的温度系数设置值(×10-5 g/㎝3/℃)(需要时 才调出数据进行显示) 故障内容显示 输出信号: 模拟输出:4~20mA DC(负载电阻不大于 500 Ω),及 0~1V DC(负载电阻≥250Ω),隔离输出。 转换为参比温度下的密度(g/㎝3) 测量温度下的密度(g/㎝3) 数字输出:RS-232-C 测量液体温度 校正状态 故障报警 输出信号量程:0.05~0.5 g/㎝3可设置 参比温度设置:0~100℃(增加或减少量为 1℃) 故障状态的触点输出:一点。触点在故障状态下或电源故 障时关闭。正常时打开。 允许电压:220V DC,250V AC 允许电流:2A(电阻负载) 允许触点功率:60W 故障检查内容:探头故障和变送器故障 故障输出: 模拟信号:下降到输出信号范围的-10%时 数字信号:错误信息输出 输出信号保持:在校正或维护模式下保持 温度系数的设置范围:0~0.002g/cm3/℃ 校正顺序:用存储的液体密度进行 One-touch 校正(一点或 两点校正) 环境温度:-10~55℃ 电源:90~132V AC 或 180~264V AC,50/60Hz 箱体结构:防尘和防雨结构 涂层颜色:门 相当于 2.8GY/6.4/0.9
相关文档