OYO9256P温湿度控制器用户操作说明书
Лакрос 温湿度监测器用户指南 说明书
GENERAL USE AND APPLICATIONSUse your smartphone, tablet or computer to remotely monitor ambient temperature and humidity levels that affect your home second home, office or rental property.* The 6 foot detachable dry probe measures temperature of air outside through a window, or even in your refrigerator or freezer.* Text & e-mail alerts can signify power outages to help you protect property or prevent frozen pipes.* More information.MONITORING OPTIONS•Home, second home, office or rental property•Indoor or outdoor temperature and humidity •Basement, garage, attic and utility room •Refrigerators, freezers and dry food storage•Plants, gardens and greenhouses•Outdoor pets, farms and livestock•Books, photos and musical instruments•Computers, servers and electronics•Wine storage and humidors•Fireplace mantelPACKAGE CONTENTSHARDWARE:1. Wireless Ambient Temperature and HumidityMonitor with mounting bracket (TX60U-IT)2. **Optional temperature probe on 6 Ft. detachable cable3. Internet Gateway with mounting bracket,AC adapter and LAN cable4. Mounting hardware (screws and drywall anchors) PRINTED MATERIALS:5. Printed Product Overview Guide (this document)IMPORTANT: Product set up and activationinstructions are online: 6. IMPORTANT: Activation Key Card is required forset up & activation of every device. Do not throw away.•Two fresh AAA, IEC LR03, 1.5V Alkaline batteries•Two-sided tape as needed•Browser with high speed Internet•Network routerFEATURES AND MEASUREMENTS (Diagram 1)(A) Wireless Ambient Temperature & Humidity Monitor:•LCD displays ambient air temp. & humidity (CH1)•LCD displays probe temperature (CH2)•Transmits collected data to Internet Gatewaywithin a 200 Ft. wireless range.•Weather resistant case (not water proof)Note: The case with LCD cannot get wet andmay be affected by high humidity conditions.•Wall hanging or free standing(B) **Optional Temp. Probe on 6 Ft. Detachable Cable:•Wet & Dry temperature probes are sold separately.Check your retailer for availability. Attach a probe atany time with no need to reset sensor.•**Attach a dry temperature probe to the main sensorcase to monitor DRY environments such as air or drysoil. MODEL #: D000.101.BG•**Or attach a Wet probe for measuring wet or humidconditions such as a pool, aquarium or terrarium:MODEL #: D000.102.BG or D000.103.BGHOW IT WORKS•The wireless sensor transmits temp. & humidity data to theInternet Gateway (200 Ft. [60.96m] wireless range).*•The Internet Gateway connects to your existing networkrouter and uses your high-speed Internet connection toupload collected measurements to your own account at.*•Once the sensor and gateway are activated on youraccount, you can monitor sensor(s) online from asmartphone, tablet or computer, and set up custome-mail/text alerts*.•Add up to 5 sensors (sold separately) perInternet gateway to monitor additional areas.(1) (2)(B)**Optional externalin select packages.**1. Begin set up near your existing network router and a computer with high-speed Internet access.2. Unpack package contents and insert the temperature probe into the TX60U-IT case (see diagram 1).1. Locate the Activation Key Card in the package for setupinstructions and the Activation Key . A unique Activation Key is necessary to activate your sensor and InternetGateway. Please keep your Activation Card for reference. 2. Visit with your Activation KeyCard to create your account and activate the product.ACTIVATION INFORMATION:THE INCLUDED ACTIVATION KEY is good for1 year of ENHANCED SERVICE with early warning text & e-mail alerts, plus 4 more years of BASIC SERVICE for standard remote monitoring for a total of 5 years.Lost your Activation Key Card?Contact Customer Support:/support/alerts Phone: (608) 785-7920Once the sensor is activated and building a measurement log, you can download the data as a comma separated values (CSV) file. You must use an application such as Microsoft Excel® or Google Docs® that supports comma separated values (CSV) formatted files to view the table data.• Select a location protected from water and otherprecipitation. The case is water resistant, not water proof. • Place the sensor in a dry, shaded area. Avoid locations with direct sun, to prevent inaccurate readings.• Fog and mist will not harm the sensor but direct precipitation must be avoided.• Note: Exposing the sensor case to extreme humidity may temporarily disrupt data. The sensor case reads humidity, but should not be submerged in water.• Select a location within range of the Internet gateway (see “IMPORTANT SETUP & OPERATION NOTES”).• IMPORTANT: Before permanently mounting…Test sensor in the desired mounting location for at least 1 hour to confirm good reception. Confirm consistent readings on your account at before permanently mounting. Move the sensor closer to the Internet Gateway if the signal is lost or not received. • Mount the sensor after the activation process (see “SETUP AND ACTIVATION”).MOUNT TO WALL WITH SCREWS1. Remove the mounting bracket2. Place bracket over the desired location.3. Mark mounting surface with a pencil through the 2 holes of the bracket.4. Screw bracket onto surface and tighten screws to bracket.5. Insert the sensor back into the bracket.FREE STANDINGAttach the mounting bracket to the bottom or top of the sensor and place it on any flat surface.PLACEMENT OF TEMPERATURE PROBE (Optional)• Confirm that the end of the probe cable is secured in the socket inside the sensor (See Diagram 1).• Insert the dry temperature probe MODEL #: D000.101.BG on 6 Ft. cable into a refrigerator or freezer, or dry soil, etc. for a separate reading of air or soil temperature.• The dry temperature probe wire is not for use in water. **An optional wet probe should be used to measure wet environments (sold separately). Check your retailer for availability: MODEL #: D000.102.BG or D000.103.BG• Loosely coil and secure extra cord with a twist tie or secure with tape (not included).• The sensor has a wireless range of 200 feet (60.96 m). The 200 ft. range equates to open air with no obstructions, and that radio waves DO NOT curve around objects. Actualtransmission range will vary depending on what is in the path of the signal. Each obstruction (roof, walls, floors, ceilings, etc.) will effectively cut signal range in half.• Metal, stucco, and some types of glass can reduce signal range by as much as ¾ or more, compared to the ½ reduction typical of most obstructions. It is possible toreceive a signal through these materials, however maximum range will be reduced due to their tendency to absorb or reflect a much larger portion of the sensor’s signal.• The sensor measures and updates the temperature and humidity on the LCD every 6 seconds.Note : The new measurement is reported to your account at intervals that you select using your online account.1. Remove the battery cover by sliding the cover down.2. Observing the correct polarity install 2-AAA batteries. The batteries will fit tightly (to avoid start-up problems make sure they do not spring free).3. Do not mix old and new batteries.4. Do not mix alkaline, lithium, standard or rechargeable batteries.5. Replace the battery cover by sliding upwards and check that it is securely fitted.• Low battery icon appears on LCD when batteries are low. • You will receive an e-mail or mobile text message alert when the battery power of the sensor is low. Change the batteries immediately.Note: The LED light turns ON briefly after changing batteries. The LED light turns OFF when not needed to save battery power. The previously stored information in the temperature and humidity sensor will not be affected or cancelled while you change the batteries.• Avoid extreme temperatures, vibration and shock. • Clean the sensor with a soft, damp cloth. Do not use solvents or scouring agents.• Do not submerge the sensor case in water. • Do not kink the 6 ft. sensor cable.• Secure the 6 ft. cable to avoid tripping hazards.• Immediately remove all low powered batteries to avoid leakage and damage.• Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology® for repairs: /support/alerts . Temperature range:-40°F to 140°F with 0.2°F resolution“OFL” displayed if outside this range. Humidity measuring range: 3% to 99% Transmission range:200 feet (60.96 m) in open space*Optional Temp. Probe: Channel 2:-40°F to 140°F with 0.2°F resolution “OFL” displayed if outside this range, and displayed “nC” if probe is not connected.Sensor battery power 2 x AAA Alkaline, IEC LR03, 1.5V Internet gateway power: AC adapter (included) Battery life cycle:Approximately 24 monthsTX60U-IT size: 5.23" H x 0.76" W x 1.44" DSee the entire product line including temp./humidity monitors, water leak detectors and remote weather stations at: /alerts/La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only beperformed by a La Crosse Technology, Ltd authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and products assume the remainingoriginal warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this warranty, or if a product isexamined which is not in need or repair, you will be charged for the repairs or examination. The owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service center. La Crosse Technology, Ltd will pay ground returnshipping charges to the owner of the product to a USA address only.Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specifiedexceptions: (1) damage caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, ordeterioration of, any accessory or decorative surface; (4)damage resulting from failure to follow instructions contained in your owner’s manual; (5) damage resulting from theperformance of repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service center; (6) units used for other than home use (7) applications and uses that this product was not intended or (8) the products inability to receive a signal due to any source of interference.. This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUMELIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH.This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do not allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or information, please contact:La Crosse Technology, Ltd2817 Losey Blvd. S. La Crosse, WI 54601/support/alertsLost your Activation Key Card?Contact Customer Support:/support/alerts Phone: (608) 785-7920* Disclaimers: La Crosse Technology, LTD. (“La Crosse”) provides various alert and monitoring services to aid users. (1) Service providers may charge users for alert services. Standard messaging and data rates apply and will be billed to the customer’s wireless account. Customers may be unable to receive text messaging or data service in some areas due to unavailability of service. (2) La Crosse shall not be liable for accuracy, usefulness or availability of data transmitted via the service. Users are solely responsible for damages to persons or property by service use.All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher.This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue.We accept no liability for technical mistakes or printing errors, or their consequences. All trademarks and patents are acknowledged.5,978,738 6,076,044 6,597,990This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:1) This device may not cause harmful interference.2) This device must accept any interference received,including interference that may cause undesired operation.LT012714。
温度控制设备说明书
U S alida de relé de 16 A
U B otón de reposición
de tecla frontal o reposición
remota U Z umbador interno audible
El CN701 se muestra en su tamaño real.
Dimensiones: mm (pulgadas)
75 (2,95)
69 (2,72)
(32 a 999 °F)
Entrada: Termopar tipo J, K o S Salida: Relé SPDT de 16 Amp @
ቤተ መጻሕፍቲ ባይዱ
Para hacer su pedido
250 Vca resistiva
Regulador de límite, 110 Vca, °C
Requisitos de alimentación: 115 Vca, 230 Vca, 12 o 24 Vca/Vcc (según el modelo)
CN703 CN704
Regulador de límite, 230 Vca, °F Regulador de límite, 230 Vca, °C
N.º de modelo Descripción
CNQUENCHARC Amortiguador RC para supresión de ruidos (2 cables), 110 a 230 Vca
(251⁄64 x 19⁄64")
Especificación de panel frontal: IP64
Consumo de energía: 4 VA Precisión: ±1% FS Pantalla: 3 dígitos, rojo, 12,7 mm (1⁄2") dígitos, más señal
恒温恒湿试验装置的操作指南说明书
恒温恒湿试验装置的操作指南说明书操作指南说明书1. 简介恒温恒湿试验装置用于对产品进行恒定温度和湿度的环境模拟测试。
本操作指南说明书将为用户提供使用该装置的必要信息和步骤,以确保正确操作并获得准确的测试结果。
2. 装置概述恒温恒湿试验装置主要由温度控制系统、湿度控制系统、测试室以及监测和记录系统组成。
用户在使用前应确保装置外部电源和供水系统正常连接。
3. 装置设置3.1 温度设置- 打开温度控制系统电源,并等待系统自检完成。
- 按照产品测试需求,在控制面板上设置所需的温度值。
- 确认温度设定正确后,按下启动按钮开始升温操作,并观察温度变化直至达到设定温度。
3.2 湿度设置- 打开湿度控制系统电源,并等待系统自检完成。
- 在控制面板上设置所需的湿度值,并确保湿度传感器正常工作。
- 按下启动按钮开始增湿操作,并观察湿度变化直至达到设定湿度。
3.3 降温操作- 在温度控制系统面板上设置所需的降温速率。
- 按下启动按钮开始降温操作,并观察温度变化直至达到设定温度。
4. 样品安装- 在测试室内选择合适的位置放置待测试样品。
- 将样品正确安装于测试室内,并确保与温度和湿度传感器接触良好。
5. 数据监测与记录- 确认监测和记录系统已正常工作。
- 在测试过程中,及时监测并记录温度和湿度的变化。
- 如发现异常情况,应及时停止测试并检查装置是否正常工作。
6. 理想测试环境维护- 定期检查并清洁测试室以确保整体环境卫生。
- 对装置进行日常维护,并定期更换传感器以保证测试数据的准确性。
- 定期校准温度和湿度传感器,以确保装置的测试准确性。
7. 安全操作- 在操作前,必须熟悉本操作指南,并佩戴适当的防护装备。
- 禁止将任何物品堆放于装置上方,以确保良好的通风。
- 定期检查电源线、供水管道等设施是否存在损坏,确保操作安全。
8. 异常情况处理- 如遇到装置故障或异常情况,应立即停止测试并通知维修人员进行检修。
- 在测试前,应检查供电和供水系统是否正常工作。
温度控制仪的操作规程(3篇)
第1篇一、设备准备1. 确认温度控制仪已正确连接电源,且电源开关处于关闭状态。
2. 检查温度控制仪的传感器是否完好,并与被测物体正确连接。
3. 确认温度控制仪已安装并固定在稳定的位置,避免震动和倾斜。
二、操作步骤1. 开启温度控制仪电源,等待设备初始化。
2. 设置温度控制仪的温度设定值:a. 按下“设定”键,进入设定模式。
b. 使用“加”、“减”键调整温度设定值。
c. 确认设定值后,按下“确认”键,退出设定模式。
3. 设置温度控制仪的工作模式:a. 按下“模式”键,选择所需的工作模式(如:恒定温度、定时加热、定时冷却等)。
b. 使用“加”、“减”键调整工作模式。
c. 确认工作模式后,按下“确认”键,退出设定模式。
4. 检查温度控制仪的报警设置:a. 按下“报警”键,进入报警设置模式。
b. 使用“加”、“减”键调整报警温度。
c. 确认报警温度后,按下“确认”键,退出设定模式。
5. 启动温度控制仪:a. 确认所有设置完成后,按下“启动”键,开始工作。
b. 温度控制仪开始根据设定值进行温度控制。
6. 监控温度控制仪的工作状态:a. 观察温度控制仪显示屏,了解当前温度、设定温度、报警温度等信息。
b. 如有异常情况,及时调整设定值或停止工作。
三、注意事项1. 温度控制仪在运行过程中,禁止触碰传感器、加热器等部件,以免发生危险。
2. 在调整温度设定值时,请确保温度设定值在设备允许的工作范围内。
3. 温度控制仪运行时,禁止将其放置在易燃、易爆、腐蚀性等有害环境中。
4. 温度控制仪运行过程中,如需停止工作,请先关闭“启动”键,再关闭电源开关。
5. 定期检查温度控制仪的传感器、加热器等部件,确保设备正常运行。
6. 如发现设备故障,请立即停止使用,并联系专业人员进行维修。
四、维护保养1. 定期清洁温度控制仪的显示屏、按键等部件,保持设备整洁。
2. 定期检查温度控制仪的电源线、传感器线等连接线,确保连接牢固。
3. 按照设备说明书进行定期维护保养,确保设备正常运行。
恒温控制器用户操作指南说明书
Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type.Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types,(select k -for type "K" CHROMEGA ®/ALOMEGA ®)J K T E N DIN J R S B C - TC types J k t E N dN J R S b C - DisplayStep 13. Store TC typeAfter you have selected the Thermocouple type press d to store your selection, the instrument automatically advances to the next menu item.Step 14. Enter to Reading Configuration MenuThe display shows RDG Reading Configuration, which is the top menu for 4 submenus: Decimal Point, Degree Units,Filter Constant and Input/Reading Submenus.Step 15. Enter to Decimal Point Submenu Press d to show DEC Decimal Point.Step 16. Display the Decimal Point positionPress d again to display the flashing Decimal Point position.Step 17. Select the Decimal Point position Press b to select FFF.F Decimal Point position.Step 18. Store selected Decimal Point positionBy pressing d momentarily the Decimal Point position will be stored and the instrument will go to the next menu item.Step 19. Enter to Temperature Unit Submenu Display shows TEMP Temperature Unit.Step 20. Display available Temperature Units Press d to display the flashing Degree °F or °C .Step 21. Scroll through Temperature Units selection Press b to select °F Degree.Step 22. Store the Temperature UnitPress d to display momentarily that the Degree Unit has been stored and the instrument will go automatically to the next menu item.Step 23. Enter the Filter Constant Submenu Display shows FLTR Filter Constant Submenu.Step 24. Display the Filter Constant Value Submenu Press d to display the flashing, previously selected Filter Constant.Step 25. Scroll through available Filter Constants Press b to sequence thru Filter Constants 0001, 0002,0004, 0008, 0016, 0032, 0064and 0128.Step 26. Store the Filter ConstantPress d momentarily to store 0004Filter Constant and the instrument will automatically go to the next menu item.Step 27. Enter Alarm 1 MenuPress a until the ALR1Alarm 1 Menu appears on the Display. In the following steps we are going to DisableLatch, Active Above, Deadband 020.0, and above Setpoint 1Value will activate Alarm 1.Step 28. Select Latch Type SubmenuPress d to display flashing DSBL / ENBL .If flashing DSBL is displayed, press a , if ENBL is displayed, press buntil DSBL is displayed, then press d to store and go to the next menu item.Step 29. Select the Above Type of Active Submenu Press d . If flashing ABoV Above is displayed, press a ,otherwise press b until ABoV is displayed. Press d to store and advance to next menu item.MQS3716-SM/0305iLD24 Big Display Universal Temperature&ProcessSimplified Menu (-SM)WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 61 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal five (5) year product warranty to cover handling and shipping time. T his ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evalua-tion. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, includ-ing but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modifica-tion. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its vari-ous products. However, OMEGA neither assumes responsibil-ity for any omissions or errors nor assumes liability for any damages that result from the use if its products in accordance with information provided by OMEGA, either verbal or writ-ten. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warran-ty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical appli-cations or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANT Y/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RE URNING ANY PRODUC (S) O OMEGA, PURCHASER MUS OB AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). T he assigned AR number should then be marked on the outside of the return package and on any correspondence.FOR WARRANTY RETURNS, please have the followinginformation available BEFORE contacting OMEGA:1. Purchase Order number under which the product was PURCHASED,2.3. Model and serial number of the product under warranty, and Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:1. P urchase Order number to cover the COST of the repair or calibration,2.3.Model and serial number of the product, and R epair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a trademark of OMEGA ENGINEERING, INC.© Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. T his document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.***********************Servicing North America:Omega Engineering, Inc.Toll-Free: 1-800-826-6342 (USA & Canada only)Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail:**************For Other Locations Visit /worldwidehis Quick Start Reference provides information on setting up your instrument for basic operation. The latest complete Communication and Operational Manual as well as free Software and ActiveX Controls are available at or on the CD-ROM enclosed with your shipment .SAFETY CONSIDERATIONThe instrument is a panel mount device protected in accordance with EN 61010-1:2001, electrical safetyrequirements for electrical equipment for measurement, control and laboratory.Remember that the unit has no power-on switch. Building installation should include a switch or circuit-breaker that must be compliant to IEC 947-1 and 947-3.SAFETY:•Do not exceed voltage rating on the label located on the back of the instrument housing.•Always disconnect power before changing signal and power connections.•Do not use this instrument on a work bench without its case for safety reasons.•Do not operate this instrument in flammable or explosive atmospheres.EMC:•Whenever EMC is an issue, always use shielded cables. •Never run signal and power wires in the same conduit.•Use signal wire connections with twisted-pair cables.•Install Ferrite Bead(s) on signal wire close to the instrument if EMC problems persist.。
恒温恒湿箱的使用方法说明书
恒温恒湿箱的使用方法说明书[恒温恒湿箱使用方法说明书]一、概述恒温恒湿箱是一种用于控制温度和湿度的设备,广泛应用于实验室、医疗机构、药品储存、食品加工等领域。
本使用方法说明书将详细介绍恒温恒湿箱的正确使用方法,以确保设备的有效运行和安全性。
二、安全注意事项1. 在使用恒温恒湿箱之前,请仔细阅读说明书,并确保你已经了解相关安全注意事项。
2. 确保设备的电源符合电源要求,并使用正确的插座进行连接。
3. 在使用设备过程中,务必保持通风良好的环境,以避免设备过热或产生其他潜在风险。
4. 使用设备时要小心操作,避免向内部投放易燃、易爆物品,以免引发火灾或爆炸等危险。
三、设备操作步骤1. 打开设备电源开关,待设备启动时,显示屏将显示当前室内温度和湿度信息。
2. 根据实际需求,使用控制面板上的按钮或旋钮调整所需要的温度和湿度设定值。
确保设定值在设备的工作范围内。
3. 在设定好温度和湿度后,将待测试或存储的样品放置在恒温恒湿箱的合适位置,并确保样品之间有足够的空间以保证空气流通。
4. 如果需要控制设备的工作时间,可以使用定时功能进行设定。
根据实际需求,设置合适的工作时间和停止时间。
5. 确认所有设置无误后,关闭恒温恒湿箱的门,以确保室内环境的稳定性。
请注意,频繁开关门可能会对设备的稳定性产生不利影响,尽量避免。
四、设备维护保养1. 定期检查设备的电源线和连接线是否完好,如有损坏或老化,应及时更换或修复。
2. 清洁设备内部和外部的脏污,建议使用柔软的纱布和中性洗涤剂进行擦拭,避免使用含酸碱强腐蚀性的清洁剂。
3. 恒温恒湿箱内部应定期清理,以确保设备的正常运行。
清理过程中,请务必断开电源,并遵循操作手册中的清洁指南。
4. 设备的维护保养及故障排除必须由专业技术人员进行,禁止非专业人员私自拆卸和维修设备。
五、常见问题及解决方法1. 设备无法启动:检查电源是否连接正常,排除电源故障;检查设备的保险丝是否损坏,如有需要更换。
温湿度控制器使用说明书
恒温恒湿控制系统使用说明书天英科技创新协会一、 概述 恒湿恒温控制器用于封闭空间温湿度控制,通过传感器采集,与执行设备构成闭环回流系统。
温湿度传感器采用模拟器件设计,其抗干扰能力强,传输距离远,精度准确。
并具备抗潮湿、抗腐蚀等优点。
设备面板如下图所示:恒温恒湿控制器加湿温度湿度▲▲●加湿恒湿去湿定时加湿加温恒温制冷风机%RH 菜单 设定 设定 加数 减数 确定℃温度上限 温度下限 湿度上限 湿度下限实时温度实时湿度二、 功能特点1、 上电校准功能,可对温湿度传感器进行自动校准;2、 湿度范围可根据客户要求任意设定。
示例:如设定上限湿度95%,下限湿度75%,也就是说湿度在75%-95%之间范围内循环加湿和去湿动作。
如湿度低于74%值,立即启动加湿设备工作。
如湿度高于96%值,立即启动去湿设备工作;3、 定时模式+自动模式双重控制;4、 手动一键加湿;5、 可设定温湿度会差范围;6、 特殊客户要求型号:温度+湿度自动控制系统可定制;三、仪表输出四路继电器输出,每个继电器最大负载AC220V/10A。
四、技术指标1、测控范围:温度:0~100℃湿度:0~100%RH2、控温灵敏度:±0.1℃控湿灵敏度:±1%RH3、测温精度:±0.5%F.S.±1个字测湿精度:±3%RH F.S.±1个字4、电控定时范围:工作时间--0~99秒、0~99分停止时间--0~99秒、0~99分5、控制输出接点最大功率:控温、电流5A/AC220V;控湿、电流5A/AC220V;控时、电流5A/AC220V6、仪表工作环境:0~45℃,相对湿度不大于85%7、仪表工作电压:AC220V±10% 50HZ;仪表功耗:约6瓦五、使用方法时间按一下间和开启时间,通过加数、减数键设定大小,按确定键保存并退出。
恒温恒湿控制器说明书
温湿度可程式控制器用户使用手册说明书产品介绍该产品采用计算机技术、先进的PID控制方法对环境的温湿度进行测量和控制,并可以与恒温恒湿设备配套使用。
★显示和控制界面直观清晰,轻触式选择菜单,简单易用,性能稳定可靠。
★程式控制灵活,给用户带来性能稳定,性价比高的高端产品。
主要性能指标:1.5寸真彩触摸薄屏;2.两种控制方式:程式/定值;3.传感器类型:3路PT100输入(可选电子传感器输入);4.报警信号:4个DI外部故障报警;5.温度测量范围:-40.00℃-150.00℃,(-20.00℃—150.00℃可定制);6.湿度测量范围:20%--98%RH,误差±1%RH(此型号可增加湿度控制);7.界面语言类型:中文/英文;8.具备汉字输入功能;9.多种信号组合继电器输出,信号可进行逻辑运算(NOT,AND,OR,NOR,XOR),简称PLC编程能力;10.继电器控制方式多样化:参数->继电器模式,继电器->参数模式,逻辑组合模式,复合信号模式;11.程式编辑:可编10组程式,每组程式最大可编12段;外型尺寸:180×120×100(mm) (长×宽×深)安装开孔尺寸:170×110(mm) (长×宽)TFT分辨率:480×2721.接线端子:图12.设定值输入键数字设定输入键 名称设定输入键①数字输入键,输入所要设置的数值后点击“ENT ”即可,注:如果输入的数值超出设定范围就会在键盘中显示“INPUT ERR ”输入错误。
②名称输入键:拼音、大、小写、数字、符号等输入,点击“拼音”可切换输入;③“SP ”为空格键;④“ESC ”退出输入;⑤“CLR ”清除输入;⑥“OK ”确认输入。
图2 图33.主画面:内部设定进入画面,在任何画面点击左上角的 均可回到主画面;图44.监视画面:接通电源后约3秒后或在上图中点击“监视画面”进入以下界面:图5 ①温度设定值:设定本次实验的温度,定值状态时点击设定区域可直接设置;②湿度设定值:设定本次实验的适度,定值状态时点击设定区域可直接设置;① ② ③⑤④⑥③温度显示值:显示当前PT100探头感应的实际温度;④湿度显示值:显示当前PT100探头感应的实际湿度;⑤时间键:时间键:显示当前时间,点击此键,LCD画面就会关闭,虽然看不到画面,但仍然正常运行,再点击屏幕任何位置,画面自动开启;⑥启动键:运行启动/停止键。
温度控制设备操作指南说明书
Field settings table[6.8.2] = .... ID66F2*BLQ05CAV3*DLQ05CAV3*BLQ07CAV3*DLQ07CAV3(*1)*B*(*2)*D*4P405542-1A - 2017.047.4.1.1R/W [3-07]~[3-06], step: A.3.2.421°C7.4.1.2R/W [3-07]~[3-06], step: A.3.2.419°C7.4.1.3R/W [3-08]~[3-09], step: A.3.2.424°C7.4.1.4R/W[3-08]~[3-09], step: A.3.2.426°C7.4.2.1[8-09]R/W [9-01]~[9-00], step: 1°C 45°C7.4.2.2[8-0A]R/W [9-01]~[9-00], step: 1°C 40°C7.4.2.3[8-07]R/W [9-03]~[9-02], step: 1°C 18°C7.4.2.4[8-08]R/W [9-03]~[9-02], step: 1°C 20°C7.4.2.5R/W -10~10°C, step: 1°C 0°C7.4.2.6R/W -10~10°C, step: 1°C -2°C7.4.2.7R/W -10~10°C, step: 1°C 0°C7.4.2.8R/W-10~10°C, step: 1°C 2°C7.4.3.1[6-0A]R/W 30~[6-0E]°C, step: 1°C 55°C7.4.3.2[6-0B]R/W 30~min(50, [6-0E])°C, step: 1°C 45°C7.4.3.3[6-0C]R/W30~min(50, [6-0E])°C, step: 1°C 45°C 7.4.4R/W0: Level 11: Level 22: Level 37.4.5.1[C-0C][D-0C]R/W 0,00~990/kWh 0/kWh7.4.5.2[C-0D][D-0D]R/W 0,00~990/kWh 0/kWh7.4.5.3[C-0E][D-0E]R/W0,00~990/kWh 0/kWh 7.4.6R/W0,00~990/kWh 0,00~290/MBtu 8,0/kWh7.7.1.1[1-00]Set weather-dependent heating Low ambient temp. for LWT main zone heatingWD curve.R/W -40~5°C, step: 1°C-10°C7.7.1.1[1-01]Set weather-dependent heating High ambient temp. for LWT main zone heatingWD curve.R/W 10~25°C, step: 1°C 15°C7.7.1.1[1-02]Set weather-dependent heating Leaving water value for low ambient temp. forLWT main zone heating WD curve.R/W [9-01]~[9-00]°C, step: 1°C 45°C7.7.1.1[1-03]Set weather-dependent heating Leaving water value for high ambient temp. forLWT main zone heating WD curve.R/W[9-01]~min(45, [9-00])°C , step: 1°C 35°C7.7.1.2[1-06]Set weather-dependent cooling Low ambient temp. for LWT main zone coolingWD curve.R/W 10~25°C, step: 1°C 20°C7.7.1.2[1-07]Set weather-dependent cooling High ambient temp. for LWT main zone coolingWD curve.R/W 25~43°C, step: 1°C 35°C7.7.1.2[1-08]Set weather-dependent cooling Leaving water value for low ambient temp. forLWT main zone cooling WD curve.R/W [9-03]~[9-02]°C, step: 1°C 22°C7.7.1.2[1-09]Set weather-dependent cooling Leaving water value for high ambient temp. forLWT main zone cooling WD curve.R/W[9-03]~[9-02]°C, step: 1°C 18°C7.7.2.1[0-00]Set weather-dependent heating Leaving water value for high ambient temp. forLWT add zone heating WD curve.R/W [9-05]~min(45,[9-06])°C, step: 1°C 35°C7.7.2.1[0-01]Set weather-dependent heating Leaving water value for low ambient temp. forLWT add zone heating WD curve.R/W [9-05]~[9-06]°C, step: 1°C 45°C7.7.2.1[0-02]Set weather-dependent heating High ambient temp. for LWT add zone heatingWD curve.R/W 10~25°C, step: 1°C 15°C7.7.2.1[0-03]Set weather-dependent heating Low ambient temp. for LWT add zone heatingWD curve.R/W-40~5°C, step: 1°C -10°C7.7.2.2[0-04]Set weather-dependent cooling Leaving water value for high ambient temp. forLWT add zone cooling WD curve.R/W [9-07]~[9-08]°C, step: 1°C 8°C7.7.2.2[0-05]Set weather-dependent cooling Leaving water value for low ambient temp. forLWT add zone cooling WD curve.R/W [9-07]~[9-08]°C, step: 1°C 12°C7.7.2.2[0-06]Set weather-dependent cooling High ambient temp. for LWT add zone coolingWD curve.R/W 25~43°C, step: 1°C 35°C7.7.2.2[0-07]Set weather-dependent cooling Low ambient temp. for LWT add zone coolingWD curve.R/W10~25°C, step: 1°C 20°CA.2.1.1[E-00]R/O 0~52: Monobloc A.2.1.2[E-01]R/O 0~10: 8A.2.1.3[E-02]R/O 0: Type 1 (*1)1: Type 2 (*2)A.2.1.7[C-07]R/W0: LWT control 1: Ext RT control 2: RT control A.2.1.8[7-02]R/W 0: 1 LWT zone 1: 2 LWT zones A.2.1.9[F-0D]R/W0: Continuous 1: Sample 2: Request A.2.1.A [E-04]R/O0: No 1: YesIndoor software type Unit control methodNumber of LWT zones Pump operation modePower saving possible HighMedium Low Unit type Compressor type Comfort (cooling)Eco (cooling)Storage comfortStorage eco Reheat Comfort (heating)Eco (heating)Comfort (cooling)Eco (cooling)Comfort (heating)Eco (heating)Comfort (heating)Eco (heating)Comfort (cooling)Eco (cooling) 4P405542-1A - 2017.04(*1) *B*_(*2) *D*A.2.1.B R/W 0: At unit 1: In room A.2.1.C[E-0D]Glycol present R/W0: No 1: YesA.2.2.A [D-02]R/W0: No1: Secondary rtrn 2: Disinf. Shunt 3: Circul. Pump 4: CP & disinf. Sh A.2.2.B [C-08]R/W0: No1: Outdoor sensor 2: Room sensor A.2.2.E.1[E-03]R/W0: No BUH 1: 1 step 2: 2 steps A.2.2.E.2[5-0D]R/W0~51: 1P,(1/1+2)4: 3PN,(1/2)5: 3PN,(1/1+2)A.2.2.E.3[D-01]R/W0: No1: Open tariff 2: Closed tariff A.2.2.E.4[E-05]R/W 0: No 1: YesA.2.2.E.5[C-05]R/W 1: Thermo ON/OFF 2: C/H request A.2.2.E.6[C-06]R/W0~21: Thermo ON/OFF A.2.2.F.1[C-02]R/W0: No1: Bivalent 2: -3: -A.2.2.F.2[C-09]R/W 0: Normally open 1: Normally closed A.2.2.F.3[D-08]R/W0: No1: 0,1 pulse/kWh 2: 1 pulse/kWh 3: 10 pulse/kWh 4: 100 pulse/kWh 5: 1000 pulse/kWh A.2.2.F.4[D-09]R/W0: No1: 0,1 pulse/kWh 2: 1 pulse/kWh 3: 10 pulse/kWh 4: 100 pulse/kWh 5: 1000 pulse/kWh A.2.2.F.5[C-08]R/W0: No1: Outdoor sensor 2: Room sensor A.2.2.F.6[D-04]R/W0: No 1: YesA.2.3.1[6-02]R/W 0~10kW, step: 0,2kW 3kWA.2.3.2[6-03]R/W 0~10kW, step: 0,2kW 3kWA.2.3.3[6-04]R/W0~10kW, step: 0,2kW 0kWA.3.1.1.1R/W0: Fixed1: Weather dep.2: Fixed + scheduled 3: WD + scheduled A.3.1.1.2.1[9-01]Temperature range Minimum temp (heating)R/W 15~37°C, step: 1°C 25°CA.3.1.1.2.2[9-00]Temperature range Maximum temp (heating)R/W 37~55°C, step: 1°C 55°CA.3.1.1.2.3[9-03]Temperature range Minimum temp (cooling)R/W 5~18°C, step: 1°C 5°CA.3.1.1.2.4[9-02]Temperature range Maximum temp (cooling)R/W 18~22°C, step: 1°C 22°C A.3.1.1.5[8-05]R/W 0: No 1: Yes A.3.1.1.7[9-0B]R/W0: Quick 1: SlowA.3.1.2.1R/W0: Fixed1: Weather dep.2: Fixed + scheduled 3: WD + scheduled A.3.1.2.2.1[9-05]Temperature range Minimum temp (heating)R/W 15~37°C, step: 1°C 25°CA.3.1.2.2.2[9-06]Temperature range Maximum temp (heating)R/W 37~55°C, step: 1°C 55°CA.3.1.2.2.3[9-07]Temperature range Minimum temp (cooling)R/W 5~18°C, step: 1°C 5°CA.3.1.2.2.4[9-08]Temperature rangeMaximum temp (cooling)R/W18~22°C, step: 1°C 22°CA.3.1.3.1[9-09]R/W 3~10°C, step: 1°C 5°CA.3.1.3.2[9-0A]R/W3~10°C, step: 1°C 5°CA.3.2.1.1[3-07]Room temp. rangeMinimum temp (heating)R/W 12~18°C, step: A.3.2.416°CA.3.2.1.2[3-06]Room temp. range Maximum temp (heating)R/W 18~30°C, step: A.3.2.430°CA.3.2.1.3[3-09]Room temp. range Minimum temp (cooling)R/W 15~25°C, step: A.3.2.415°CA.3.2.1.4[3-08]Room temp. rangeMaximum temp (cooling)R/W25~35°C, step: A.3.2.435°CExternal kWh meter 1External kWh meter 2External sensor PCC by digital inputs Backup heater stepsBUH type Preferential kWh rate DHW operation Contact type main Contact type add.BUH: step 1BUH: step 2LWT setpoint modeModulated LWT Emitter typeLWT setpoint modeHeating CoolingUser interface location DHW pumpExternal sensor Booster heaterExt. backup heat srcAlarm output (*1) *B*_(*2) *D* 4P405542-1A - 2017.04A.3.2.2[2-0A]R/W -5~5°C, step: 0,5°C 0°CA.3.2.3[2-09]R/W -5~5°C, step: 0,5°C 0°CA.3.2.4R/W0: 0,5 °C 1: 1 °CA.3.3.1[4-02]R/W 14~35 °C, step: 1°C 25°CA.3.3.2[F-01]R/W10~35°C, step: 1°C 20°CA.4.1[6-0D]R/W0: Reheat only1: Reheat + sched.2: Scheduled only A.4.4.1[2-01]R/W 0: No 1: YesA.4.4.2[2-00]R/W0: Each day 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: SundayA.4.4.3[2-02]R/W 0~23 hour, step: 1 hour 23A.4.4.4[2-03]R/W 55~80°C, step: 5°C 70°CA.4.4.5[2-04]R/W5~60 min, step: 5 min 10 minA.4.5[6-0E]R/W40~80°C, step: 1°C 60°CA.4.6R/W0: Fixed1: Weather dep.A.4.7[0-0B]Weather-dependent curveLeaving water value for high ambient temp. for DHW WD curve.R/W 35~[6-0E]°C, step: 1°C 55°CA.4.7[0-0C]Weather-dependent curve Leaving water value for low ambient temp. for DHW WD curve.R/W 45~[6-0E]°C, step: 1°C 60°CA.4.7[0-0D]Weather-dependent curve High ambient temp. for DHW WD curve.R/W 10~25°C, step: 1°C 15°CA.4.7[0-0E]Weather-dependent curveLow ambient temp. for DHW WD curve.R/W-40~5°C, step: 1°C -10°CA.5.1.1[4-00]R/W0~20: Disabled 1: Enabled A.5.1.3[4-07]R/W 0: No 1: YesA.5.1.4[5-01]R/W-15~35°C, step: 1°C -4°CA.6.1[3-00]R/W0: No 1: Yes A.6.2.1[D-00]R/W0: None 1: BSH only 2: BUH only 3: All heaters A.6.2.2[D-05]R/W0: Forced off 1: As normalA.6.3.1[4-08]R/W0: No limitation 1: Continuous 2: Digital inputs A.6.3.2[4-09]R/W 0: Current 1: PowerA.6.3.3[5-05]R/W 0~50 A, step: 1 A 50 AA.6.3.4[5-09]R/W 0~20 kW, step: 0,5 kW 20 kWA.6.3.5.1[5-05]Amp. limits for DI Limit DI1R/W 0~50 A, step: 1 A 50 AA.6.3.5.2[5-06]Amp. limits for DI Limit DI2R/W 0~50 A, step: 1 A 50 AA.6.3.5.3[5-07]Amp. limits for DI Limit DI3R/W 0~50 A, step: 1 A 50 AA.6.3.5.4[5-08]Amp. limits for DI Limit DI4R/W 0~50 A, step: 1 A 50 AA.6.3.6.1[5-09]kW limits for DI Limit DI1R/W 0~20 kW, step: 0,5 kW 20 kWA.6.3.6.2[5-0A]kW limits for DI Limit DI2R/W 0~20 kW, step: 0,5 kW 20 kWA.6.3.6.3[5-0B]kW limits for DI Limit DI3R/W 0~20 kW, step: 0,5 kW 20 kWA.6.3.6.4[5-0C]kW limits for DI Limit DI4R/W 0~20 kW, step: 0,5 kW 20 kW A.6.3.7[4-01]R/W0: None 1: BSH 2: BUHA.6.4[1-0A]R/W0: No averaging 1: 12 hours 2: 24 hours 3: 48 hours 4: 72 hours A.6.5[2-0B]R/W-5~5°C, step: 0,5°C 0°CType Amp. value kW value PriorityEnable BUH step 2Equilibrium temp.Allowed heatersForced pump OFF ModeTemperature target DurationOperation mode Ext. room sensor offset Space heating OFF tempDisinfectionOperation dayStart timeRoom temp. step Space cooling On tempRoom temp. offset 4P405542-1A - 2017.04(*1) *B*_(*2) *D*A.6.A[7-05]R/W0: Very high 1: High 2: Medium 3: Low 4: Very low A.6.CR/W0: Manual 1: AutomaticA.8[0-00]R/W [9-05]~min(45,[9-06])°C, step: 1°C 35°CA.8[0-01]R/W [9-05]~[9-06]°C, step: 1°C 45°CA.8[0-02]R/W 10~25°C, step: 1°C 15°CA.8[0-03]R/W -40~5°C, step: 1°C -10°CA.8[0-04]R/W [9-07]~[9-08]°C, step: 1°C 8°CA.8[0-05]R/W [9-07]~[9-08]°C, step: 1°C 12°CA.8[0-06]R/W 25~43°C, step: 1°C 35°CA.8[0-07]R/W 10~25°C, step: 1°C 20°CA.8[0-0B]R/W 35~[6-0E]°C, step: 1°C 55°CA.8[0-0C]R/W 45~[6-0E]°C, step: 1°C 60°CA.8[0-0D]R/W 10~25°C, step: 1°C 15°CA.8[0-0E]R/W -40~5°C, step: 1°C -10°CA.8[1-00]R/W -40~5°C, step: 1°C -10°CA.8[1-01]R/W 10~25°C, step: 1°C 15°CA.8[1-02]R/W [9-01]~[9-00], step: 1°C 45°CA.8[1-03]R/W [9-01]~min(45, [9-00])°C , step: 1°C 35°CA.8[1-04]R/W 0: Disabled 1: Enabled A.8[1-05]R/W 0: Disabled 1: EnabledA.8[1-06]R/W 10~25°C, step: 1°C 20°CA.8[1-07]R/W 25~43°C, step: 1°C 35°CA.8[1-08]R/W [9-03]~[9-02]°C, step: 1°C 22°CA.8[1-09]R/W [9-03]~[9-02]°C, step: 1°C 18°CA.8[1-0A]R/W0: No averaging 1: 12 hours 2: 24 hours 3: 48 hours 4: 72 hours A.8[2-00]R/W0: Each day 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Sunday A.8[2-01]R/W 0: No 1: YesA.8[2-02]R/W 0~23 hour, step: 1 hour 23A.8[2-03]R/W 55~80°C, step: 5°C 70°CA.8[2-04]R/W 5~60 min, step: 5 min 10 minA.8[2-05]R/W 4~16°C, step: 1°C 16°CA.8[2-06]R/W 0: Disabled 1: EnabledA.8[2-09]R/W -5~5°C, step: 0,5°C 0°CA.8[2-0A]R/W -5~5°C, step: 0,5°C 0°CA.8[2-0B]R/W -5~5°C, step: 0,5°C 0°C A.8[3-00]R/W0: No 1: Yes A.8[3-01]0A.8[3-02]1A.8[3-03]4A.8[3-04]2A.8[3-05]1A.8[3-06]R/W 18~30°C, step: A.3.2.430°CA.8[3-07]R/W 12~18°C, step: A.3.2.416°CA.8[3-08]R/W 25~35°C, step: A.3.2.435°CA.8[3-09]R/W 15~25°C, step: A.3.2.415°C A.8[4-00]R/W0~20: Disabled 1: Enabled A.8[4-01]R/W0: None 1: BSH 2: BUHA.8[4-02]R/W14~35°C, step: 1°C 25°CWhat is the maximum desired room temperature in cooling?What is the minimum desired room temperature in cooling?What is the BUH operation mode?Which electric heater has priority?--------What is the maximum desired room temperature in heating?What is the mimimum desired room temperature in heating?Room frost protectionAdjust the offset on the measured room temperature Adjust the offset on the measured room temperature What is the required offset on the measured outdoor temp.?Is auto restart of the unit allowed?--When should the disinfection function be executed?Should the disinfection function be executed?When should the disinfection function start?What is the disinfection target temperature?How long must the tank temperature be maintained?Room antifrost temperature Weather dependent cooling of the additional leaving water temperature zone Low ambient temp. for LWT main zone cooling WD curve.High ambient temp. for LWT main zone cooling WD curve.Leaving water value for low ambient temp. for LWT main zone cooling WD curve.Leaving water value for high ambient temp. for LWT main zone cooling WD curve.What is the averaging time for the outdoor temp?Low ambient temp. for DHW WD curve.Low ambient temp. for LWT main zone heating WD curve.High ambient temp. for LWT main zone heating WD curve.Leaving water value for low ambient temp. for LWT main zone heating WD curve.Leaving water value for high ambient temp. for LWT main zone heating WD curve.Weather dependent cooling of the main leaving water temperature zone.Leaving water value for low ambient temp. for LWT add zone cooling WD curve.High ambient temp. for LWT add zone cooling WD curve.Low ambient temp. for LWT add zone cooling WD curve.Leaving water value for high ambient temp. for DHW WD curve.Leaving water value for low ambient temp. for DHW WD curve.High ambient temp. for DHW WD curve.Leaving water value for high ambient temp. for LWT add zone heating WD curve.Leaving water value for low ambient temp. for LWT add zone heating WD curve.High ambient temp. for LWT add zone heating WD curve.Low ambient temp. for LWT add zone heating WD curve.Leaving water value for high ambient temp. for LWT add zone cooling WD curve.Below which outdoor temperature is heating allowed?(*1) *B*_(*2) *D* 4P405542-1A - 2017.04A.8[4-03]R/W0: Limited 1: No limit2: Most optimum 3: Optimum4: Only legionellaA.8[4-04]R/W0: Continuous pump operation 1: Intermittent pump operation 2: No protection A.8[4-05]0A.8[4-06]0/1A.8[4-07]R/W 0: No 1: YesA.8[4-08]R/W0: No limitation 1: Continuous 2: Digital inputs A.8[4-09]R/W0: Current 1: Power A.8[4-0A]0A.8[4-0B]R/W 1~10°C, step: 0,5°C 1°CA.8[4-0D]R/W 1~10°C, step: 0,5°C 3°C A.8[4-0E]Is the installer on site?R/W 0: No 1: Yes A.8[5-00]R/W 0: Allowed1: Not allowedA.8[5-01]R/W -15~35°C, step: 1°C -4°CA.8[5-02]R/W 0: Disabled 1: EnabledA.8[5-03]R/W -15~35°C, step: 1°C 0°CA.8[5-04]R/W 0~20°C, step: 1°C 10°CA.8[5-05]R/W 0~50 A, step: 1 A 50 AA.8[5-06]R/W 0~50 A, step: 1 A 50 AA.8[5-07]R/W 0~50 A, step: 1 A 50 AA.8[5-08]R/W 0~50 A, step: 1 A 50 AA.8[5-09]R/W 0~20 kW, step: 0,5 kW 20 kWA.8[5-0A]R/W 0~20 kW, step: 0,5 kW 20 kWA.8[5-0B]R/W 0~20 kW, step: 0,5 kW 20 kWA.8[5-0C]R/W 0~20 kW, step: 0,5 kW 20 kW A.8[5-0D]R/W0~51: 1P,(1/1+2)4: 3PN,(1/2)5: 3PN,(1/1+2)A.8[5-0E]1A.8[6-00]R/W 2~20°C, step: 1°C 2°CA.8[6-01]R/W 0~10°C, step: 1°C 2°CA.8[6-02]R/W 0~10kW, step: 0,2kW 3kWA.8[6-03]R/W 0~10kW, step: 0,2kW 3kWA.8[6-04]R/W0~10kW, step: 0,2kW 0kW A.8[6-05]0A.8[6-06]0A.8[6-07]0A.8[6-08]R/W2~20°C, step: 1°C 10°C A.8[6-09]0A.8[6-0A]R/W 30~[6-0E]°C, step: 1°C 55°CA.8[6-0B]R/W 30~min(50, [6-0E])°C, step: 1°C 45°CA.8[6-0C]R/W 30~min(50, [6-0E])°C, step: 1°C 45°CA.8[6-0D]R/W0: Reheat only1: Reheat + sched.2: Scheduled only A.8[6-0E]R/W 40~80°C, step: 1°C 60°CA.8[7-00]R/W 0~4°C, step: 1°C 0°CA.8[7-01]R/W 2~40°C, step: 1°C 2°CA.8[7-02]R/W0: 1 LWT zone 1: 2 LWT zones A.8[7-03]2,5A.8[7-04]0A.8[7-05]R/W0: Very high 1: High 2: Medium 3: Low 4: Very low A.8[8-00] 1 minA.8[8-01]R/W 5~95 min, step: 5 min 30 minA.8[8-02]R/W 0~10 hour, step: 0,5 hour 3 hourA.8[8-03]R/W 20~95 min, step: 5 min 50 minA.8[8-04]R/W 0~95 min, step: 5 min 95 min A.8[8-05]R/W 0: No 1: YesA.8[8-06]R/W0~10°C, step: 1°C 3°CAdditional running time for the maximum running time.Allow modulation of the LWT to control the room temp?Leaving water temperature maximum modulation.--Boiler efficiency--Maximum running time for domestic hot water operation.Anti-recycling time.Booster heater delay timer.What is the desired DHW production type?What is the maximum temperature setpoint?Domestic hot water booster heater overshoot temperature.Domestic hot water booster heater hysteresis.How many leaving water temperature zones are there?----What is the hysteresis to be used in reheat mode?--What is the desired comfort storage temperature?What is the desired eco storage temperature?What is the desired reheat temperature?The temperature difference determining the heat pump OFF temperature.What is the capacity of the booster heater?What is the capacity of the backup heater step 1?What is the capacity of the backup heater step 2?----What is the requested limit for DI2?What is the requested limit for DI3?What is the requested limit for DI4?What type of backup heater installation is used?--The temperature difference determining the heat pump ON temperature.Set point correction for domestic hot water temperature.What is the requested limit for DI1?What is the requested limit for DI2?What is the requested limit for DI3?What is the requested limit for DI4?What is the requested limit for DI1?Automatic cooling/heating changeover hysteresis.Automatic cooling/heating changeover offset.Is backup heater operation allowed above equilibrium temperature during space heating operation?What is the equilibrium temperature for the building?Space heating priority.Space heating priority temperature.---- (Do not change this value)Enable the second step of the backup heater?Which power limitation mode is required on the system?Which power limitation type is required?--Operation permission of the booster heater.How to protect the water pipes from freezing 4P405542-1A - 2017.04(*1) *B*_(*2) *D*A.8[8-07]R/W [9-03]~[9-02], step: 1°C 18°CA.8[8-08]R/W [9-03]~[9-02], step: 1°C 20°CA.8[8-09]R/W [9-01]~[9-00], step: 1°C 45°CA.8[8-0A]R/W[9-01]~[9-00], step: 1°C 40°C A.8[8-0B]13A.8[8-0C]10A.8[8-0D]16A.8[9-00]R/W 37~55°C, step: 1°C 55°CA.8[9-01]R/W 15~37°C, step: 1°C 25°CA.8[9-02]R/W 18~22°C, step: 1°C 22°CA.8[9-03]R/W 5~18°C, step: 1°C 5°CA.8[9-04]R/W 1~4°C, step: 1°C 1°CA.8[9-05]R/W 15~37°C, step: 1°C 25°CA.8[9-06]R/W 37~55°C, step: 1°C 55°CA.8[9-07]R/W 5~18°C, step: 1°C 5°CA.8[9-08]R/W 18~22°C, step: 1°C 22°CA.8[9-09]R/W 3~10°C, step: 1°C 5°CA.8[9-0A]R/W 3~10°C, step: 1°C 5°CA.8[9-0B]R/W 0: Quick 1: SlowA.8[9-0C]R/W 1~6°C, step: 0,5°C 1 °CA.8[9-0D]R/W0~8, step:10 : 100%1~4 : 80~50%5~8 : 80~50%6A.8[9-0E]6A.8[A-00]0A.8[A-01]0A.8[A-02]0A.8[A-03]0A.8[A-04]0A.8[B-00]0A.8[B-01]0A.8[B-02]0A.8[B-03]0A.8[B-04]0A.8[C-00]0A.8[C-01]0A.8[C-02]R/W0: No1: Bivalent 2: -3: -A.8[C-03]R/W -25~25°C, step: 1°C 0°CA.8[C-04]R/W 2~10°C, step: 1°C 3°CA.8[C-05]R/W 1: Thermo ON/OFF 2: C/H request A.8[C-06]R/W0~20: -1: Thermo ON/OFF A.8[C-07]R/W0: LWT control 1: Ext RT control 2: RT control A.8[C-08]R/W0: No1: Outdoor sensor 2: Room sensor A.8[C-09]R/W0: Normally open 1: Normally closed A.8[C-0A]0A.8[C-0C]R/W 0~70A.8[C-0D]R/W 0~70A.8[C-0E]R/W 0~70A.8[D-00]R/W0: None 1: BSH only 2: BUH only 3: All heaters A.8[D-01]R/W0~30: No1: Open tariff 2: Closed tariff A.8[D-02]R/W0: No1: Secondary rtrn 2: Disinf. Shunt 3: Circul. Pump 4: CP & disinf. Sh A.8[D-03]R/W0: Disabled1: Enabled, shift 2°C (from -2 to 2°C)2: Enabled, shift 4°C (from -2 to 2°C)3: Enabled, shift 2°C (from -4 to 4°C)4: Enabled, shift 4°C (from -4 to 4°C)A.8[D-04]R/W 0: No 1: YesA.8[D-05]R/W0: Forced off 1: As normal A.8[D-07]Forced off contact type Is the pump allowed to run if prefer. kWh rate PS is cut?--Low electricity price decimal (Do not use)Which heaters are permitted if prefer. kWh rate PS is cut?Which type of DHW pump is installed?Leaving water temperature compensation around 0°C.Is the option box used for PCC ?What is the unit control method in space operation?Which type of external sensor is installed?What is the required alarm output contact type?--High electricity price decimal (Do not use)Medium electricity price decimal (Do not use)--Is an external backup heat source connected?Bivalent activation temperature.Bivalent hysteresis temperature.What is the thermo request contact type for the main zone?What is the thermo request contact type for the add. zone?------------------------What is the maximum desired LWT for add. zone in cooling?What is the desired delta T in heating?What is the desired delta T in cooling?What emitter type is connected to the main LWT zone?Room temperature hysteresis.Pump speed limitationWhat is the maximum desired LWT for main zone in cooling?What is the mimimum desired LWT for main zone in cooling?Leaving water temperature overshoot temperature.What is the mimimum desired LWT for add. zone in heating?What is the maximum desired LWT for add. zone in heating?What is the mimimum desired LWT for add. zone in cooling?What is the desired eco main LWT in heating?------What is the maximum desired LWT for main zone in heating?What is the mimimum desired LWT for main zone in heating?What is the desired comfort main LWT in cooling?What is the desired eco main LWT in cooling?What is the desired comfort main LWT in heating?(*1) *B*_(*2) *D* 4P405542-1A - 2017.04A.8[D-08]R/W0: No1: 0,1 pulse/kWh 2: 1 pulse/kWh 3: 10 pulse/kWh 4: 100 pulse/kWh 5: 1000 pulse/kWh A.8[D-09]R/W0: No1: 0,1 pulse/kWh 2: 1 pulse/kWh 3: 10 pulse/kWh 4: 100 pulse/kWh 5: 1000 pulse/kWh A.8[D-0A]0A.8[D-0B]2A.8[D-0C]R/W 0~490A.8[D-0D]R/W 0~490A.8[D-0E]R/W 0~490A.8[E-00]R/O 0~52: Monobloc A.8[E-01]R/O 0~10: 8A.8[E-02]R/O 0: Type 1 (*1)1: Type 2 (*2)A.8[E-03]R/W0: No BUH 1: 1 step 2: 2 steps A.8[E-04]R/O 0: No 1: Yes A.8[E-05]R/W0: No 1: Yes A.8[E-06]1A.8[E-07]0A.8[E-08]R/W0: Disabled 1: Enabled A.8[E-09]0A.8[E-0A]0A.8[E-0B]0A.8[E-0C]0A.8[E-0D]Is the system filled with glycol ?R/W 0: No 1: YesA.8[F-00]R/W 0: Disabled 1: EnabledA.8[F-01]R/W10~35°C, step: 1°C 20°C A.8[F-02]3A.8[F-03]5A.8[F-04]0A.8[F-05]0A.8[F-06]0A.8[F-09]R/W0: Disabled 1: Enabled A.8[F-0A]0A.8[F-0B]0A.8[F-0C]1A.8[F-0D]R/W0: Continuous 1: Sample 2: Request--Above which outdoor temperature is cooling allowed?What is the number of backup heater steps?Is the power saving function available on the outdoor unit?Can the system prepare domestic hot water?--------Pump operation during flow abnormality.--------Pump operation allowed outside range.What is the pump operation mode?----------Power saving function for outdoor unit.What is the high electricity price (Do not use)What is the medium electricity price (Do not use)What is the low electricity price (Do not use)Which type of unit is installed?Which type of compressor is installed?What is the indoor unit software type?Is an external kWh meter used for power measurement?Is an external kWh meter used for power measurement?---- 4P405542-1A - 2017.04(*1) *B*_(*2) *D*。
温控仪操作说明
1.手动/自动无扰动切换按A/M键,MAN指示灯亮,进入手动状态。
当前SV显示器数值即为输出百分比,PV 显示器为测量值。
用“向左”、“向上”和“向下”键可手动修改输出百分比。
再按A/M 键,MAN指示灯熄灭,仪表进入自动状态。
此时,SV显示原设定值,PV显示仍为测量值。
仪表在任何状态下均可进入手动/自动状态。
2.人工修改PID参数在LEVEL1下,按SET键5s进入LEVEL2,按SET键选择P、I和D参数选项即可进行设定。
3.室温显示修正热电偶分度号输入时,若输入端子短接,仪表显示值应近似为室温,若有较大差异,同时按下SET键和“向左”键,进入LEVEL3,然后按SET键数次,找到PVS选项,人工设定修正PVS值。
4.恒温定时报警设定需设定恒温报警时,先选择报警组别(AL1和AL2均可),并设定报警模式为9,然后对该组AL输入定时数值(单位为min)。
当PV=PS时,该组别报警灯亮(继电器无动作),并立刻开始计时(预设定时数值递减为0000),定时结束,报警继电器动作。
5.软启动预置斜率控制(选配)当系统需要软启动时(SV预置斜率升温),按如下顺序操作:设定好SV值→在LEVEL1下按SET键找到RAP选项,设定好温度→按SET键找到RTM选项,设定斜率时间(单位为min)。
例如要设斜率为10℃/min时,RAP设为10.0,RTM设为001.0即可。
设定完毕,软启动将会立即从当前的PV值按斜率升温,直到PV=SV为止。
若需暂停斜率升温,同时按下SET键和“向上”,SV数值可任意修改,进行定值控制。
若要取消软启动,输入0.0℃/min即可。
6.除湿功能(选配)需除湿时按如下顺序操作:在LEVEL3下,按SET键数次找到SRT选项,预置除湿工作时的输出百分比,可预置V=2.0-5.0(例如,SRT设为40℃,LMO设为2.0,即仪表开机时系统的温度低于40℃时,仪表以2%的功率输出,这样可避免烧坏加热器)。
温湿度控制器说明书
030温湿度控制器安装使用说明书V2.0申明版权所有,未经本公司之书面许可,此手册中任何段落,章节内容均不得被摘抄、拷贝或以任何形式复制、传播,否则一切后果由违者自负。
本公司保留一切法律权利。
本公司保留对手册所描述之产品规格进行修改的权利,恕不另行通知。
订货前,请垂询当地代理商以获悉本产品的最新规格。
江苏安科瑞电器制造有限公司吴磊磊提供135********目录前言 (1)1概述 (1)2工作原理 (1)一WH系列普通型温湿度控制器 (1)1型号说明 (1)2技术指标 (2)3产品规格及功能 (2)4接线方式 (4)二WHD系列智能型温湿度控制器 (5)1型号说明 (5)2技术指标 (5)3产品规格及功能 (6)4接线方式 (6)5产品操作指南 (8)6通讯指南 (11)三传感器 (15)1概述 (15)2型号说明 (15)前言:温湿度控制器简介1概述温湿度控制器产品主要用于中高压开关柜、端子箱、环网柜、箱变等设备内部温度和湿度的调节控制。
可有效防止因低温、高温造成的设备故障以及受潮或结露引起的爬电、闪络事故的发生。
产品分为WH普通型系列和WHD智能型系列。
产品符合国标GB/T15309-1994。
2工作原理温湿度控制器主要由传感器、控制器、加热器(或风扇等)三部分组成,其工作原理如下图所示:传感器检测箱内温湿度信息,并传递到控制器由控制器分析处理:当箱内的温度、湿度达到或超过预先设定的值时,控制器中的继电器触点闭合,加热器(或风扇)接通电源开始工作,对箱内进行加热或鼓风等;一段时间后,箱内温度或湿度远离设定值,控制器中的继电器触点断开,加热或鼓风停止。
除基本功能外不同型号还带有断线报警输出、变送输出、通信、强制加热鼓风等辅助功能。
一.WH系列普通型温湿度控制器1型号说明注:1.“组合外接”即同时有温度、湿度控制时,传感器置于同一外壳,由同一点采集温度、湿度信息。
2.传感器与控制器之间的连接线长度建议不要超过20米。
温控器说明书
温湿度控制器一、产品概述温湿度控制器,主要应用于需要对被测环境进行自动温湿度调节的场合,用户可通过按键分别调整温湿度的上、下限值来控制加热或排风实现自动控制,显示方式为数码管显示。
二、基本功能:2.1 温度测量范围:-25℃~+80℃±1℃;2.2 湿度测量范围:相对湿度RH: 0%~99% 精度±3%RH;2.3 控制方式:温度采用上、下限和回差控制,湿度采用上、下限控制,所有参数均可设置;2.4 输出控制类型:两组继电器触点,分别为加热和排风,每路最大负载AC250V /3A,均为有源输出。
三、技术指标:3.1电源:AC 220V±20%3.2 工作环境:温度:-25℃~+55℃,相对湿度:<95%RH3.3控制设定范围:温度:0℃~80℃,相对湿度:50%RH~99%RH3.4 本机功耗:<3W3.5自检功能:若数码管显示“–––”,则为检测到传感器故障;若加热或排风运行过程中相应指示灯熄灭,则检测到加热或排风故障。
四、工作原理:4.1 温度控制:当被测环境温度低于设定温度下限时,本仪器启动电加热设备开始加温,此时加热指示灯亮,温度升至比下限温度设定值高回差值时,即:W测≥W下限+回差,停止加温。
当被测环境温度高于设定温度上限时,本仪器启动降温设备(如风机或空调)开始降温,此时排风指示灯亮,温度降至比上限温度设定值低回差值时,即:W测≤W上限-回差,停止降温。
4.2 湿度控制:当被测环境湿度超过设定湿度上限时。
如果当前温度较高,即:W测≥W下限+(W上限-W下限)×3÷4,采用降温(或排风,视具体地区采用不同设备)抽湿,此时排风指示灯亮;抽湿过程中,如果温度低于下限温度+2度后,自动转为加热降湿;当降湿过程中温度高于上限温度-2度后,自动转为降温抽湿,直至湿度低于设定下限值为止。
当被测环境湿度超过设定湿度上限时。
如果当前温度较低,即:W测<W下限+(W上限-W下限)×3÷4,采用加热降湿,此时加热指示灯亮,降湿过程中,如果温度高于上限温度-2度后,自动转为降温抽湿;当温度低于下限温度+2度后,自动转为加热降湿,直至湿度低于设定下限值为止。
温湿度记录仪操作规程(3篇)
第1篇一、概述温湿度记录仪是一种用于监测和记录环境温湿度的电子设备,广泛应用于实验室、冷库、仓储、农业等领域。
为确保记录仪的正常使用和数据准确性,特制定本操作规程。
二、适用范围本规程适用于所有型号的温湿度记录仪,包括但不限于DLM11C(蓝牙版)等。
三、操作步骤1. 开机与设置- 短按开机键,启动记录仪。
- 观察显示屏,确保显示信号、定位、云图标、电量和当前环境温度,确认设备开机正常。
- 根据需要,设置记录仪的报警参数,如温度上限、下限,湿度上限、下限等。
2. 记录数据- 长按启停键,显示屏左下角出现三角图标,开始记录打印数据。
- 温度超限时,设备会发出“滴滴滴”的声音,指示灯为橙色闪烁,请注意查看并处理。
- 需要停止记录时,长按启停键,显示屏左下角三角图标变为正方形图标,停止记录打印数据。
3. 轮询查看- 短按打印键进行轮询查看,依次显示当前温度、温度最大值、温度最小值、当前湿度、湿度最大值、湿度最小值、剩余使用天数、当前版本号等信息。
4. 蓝牙打印- 长按打印机开机键,打印机显示为红色指示灯。
- 长按记录仪打印键,电量左边出现打印图标。
- 等待打印机从红色指示灯自动转为蓝色指示灯。
- 短按记录仪打印键,打印机图标闪烁,开始打印。
5. 关机- 同时长按打印键与开机键3秒以上,显示屏关闭,完成关机操作。
四、注意事项1. 设备处于打印状态下无法记录数据,需退出打印模式后才能记录数据。
2. 设备开机后需要等待设备搜索信号,连接平台,显示屏上出现云图标后,再进行发运操作。
3. 设备停止发运后,如需重新开始记录,请重新开启记录仪并设置相关参数。
4. 定期检查记录仪的电量,确保设备正常工作。
5. 避免将记录仪置于高温、潮湿或阳光直射的环境中,以免影响设备性能。
6. 使用完毕后,请妥善保管记录仪,避免损坏。
五、维护与保养1. 定期清洁记录仪,保持设备表面干净。
2. 定期检查记录仪的传感器,确保其正常工作。
3. 如发现设备故障,请及时联系专业人员进行维修。
温控器使用说明书
一周编程电子智能室内温控器LOGIC 578001使用指南引言感谢您选择了我们的产品及对我们的信任与支持。
本装置是电子式定时恒温器,可设置一星期为周期的运行程序。
通过该装置,可对安装环境内的温度进行十分精确的调节控制,满足用户对创造一个舒适生活环境的要求。
符合标准:符合欧盟法令:EN 60730-1 标准及其修订内容欧盟B.T.73/23/EEC号法令EN 60730-2-7 标准欧盟 E.M.C.89/336/EEC号法令及93/68/EEC修改法令EN 60730-2-9 标准产品规格:电源:二节LR6型1.5V碱性电池温度调节范围:10至35℃显示屏显示之环境温度:0至40℃(分辩率0.1℃)温度修正频率:每分钟一次微分:0.2至0.4K探针传感器:NTC3%保护等级:IP20绝缘等级:热梯度:1K/15分输出:转换继电器触点容量:8(2.5)A250V~作用类型:1BU绝缘条件:正常环境最大工作温度:50℃储存温度:0-60℃防冻温度:6℃恒定运行程序:以一星期为周期设置软件等级:A液晶显示屏夏季/冬季(采暖/空调)切换程序设置中的最小增减允许时间:1小时安装:壁式安装安装及连接:安全预防措施在进行定时恒温器的连接之前,请确认受其控制的设备系统(采暖锅炉、泵和空调系统等)电源已断开,并需检查这些设备的使用电压是否与定时恒温器底座上表明的电压相符(最大250V~).(图4)安装位置定时恒温器须安装在远离热源(暖气装置、阳光、厨房)和门窗之处,安装高度离地面约1.5米。
(图5)安装见图6-7-8电气连接将受定时恒温器控制的设备系统电线与定时恒温器的1号及2号接线柱连接见接线图10所示U=受定时恒温器控制的设备1=共用接线柱2=常开接线柱3=常闭接线柱重要事项:请务必严格遵照相关现行法律的规定及安全规范安装定时恒温器。
电池更换:当在显示屏上闪烁显示“”标志时,定时恒温器还可正常工作约一个月左右,然后将会停止工作并固定显示“”。
温控仪使用说明范文
温控仪使用说明范文一、产品简介:温控仪是一种用于调节和控制温度的电子设备,主要应用于家庭、办公场所、实验室等各种温度控制领域。
它可根据用户的需求,自动调节和维持设定的温度范围,确保环境温度的舒适性和稳定性。
二、外观和控制面板介绍:1.外观:温控仪的外观一般为方形或长方形的盒状结构,材质多为塑料或金属,外壳上有显示屏、控制按钮和接口等。
2.显示屏:显示屏通常为液晶显示屏,用于显示当前的温度、设定的温度、工作状态等。
3.控制按钮:控制面板上通常有一些按钮,用于设定温度、选择工作模式、调节参数等。
4.接口:接口可以分为电源接口、控制接口和外部设备接口等,用于供电、控制和连接其他设备。
三、基本使用方法:1.电源连接:将温控仪的电源适配器插头插入电源插座,确保电源供应稳定。
2.温度传感器连接:根据温度传感器的类型和规格,将其插入温控仪的温度传感器接口。
3.设定温度:通过控制按钮,在显示屏上设定所需的温度范围。
根据不同的温控仪型号,设定方法可能略有差异,但通常需要按下设定按钮,然后使用加减按钮来调节目标温度,并保存设定值。
4.选择工作模式:温控仪通常提供多种工作模式,如制冷模式、加热模式、自动模式等。
根据需要,选择相应的工作模式,并进行设定。
5.调节参数:一些温控仪还提供一些可调节的参数,如温度回差、控温精度等。
根据需要,进行相应的参数调节。
6.启动和关闭:根据所设定的温度和工作模式,按下启动按钮使温控仪开始工作。
需要关闭时,按下关闭按钮将其停止工作。
四、注意事项:1.请阅读说明书:在使用温控仪前,请仔细阅读产品的说明书,了解其功能和使用方法。
2.正确安装传感器:温度传感器是温控仪的重要组成部分,需正确安装在需要测量温度的地方,避免误差。
3.避免灰尘和水汽:避免温控仪长时间处于灰尘多、湿度高的环境中,以免影响其正常工作。
4.保持通风:温控仪应放置在通风良好的位置,避免阳光直射和高温环境,以保证其散热效果和寿命。
温湿度控制仪表说明书
温湿度控制仪使用说明书温湿度控制仪,具有温湿度同时数字显示,控制值分别显示、定时打印记录等功能,仪表同时具有电压监测功能,缺水保护功能(内部有水位传感器输入接口,只要配接水位传感器,就可以适用需要缺水指示或报警的场合),内置循环定时器,使控制更加灵活,设备配上该仪表,将使其具有很高的自动控制功能。
一、主要技术指标1.1控温范围:0℃----50℃1.2控温灵敏度:±0.5℃控湿灵敏度:±2%RH1.3测温准确度:±0.3℃测湿准确度:5% ~ 7%RH1.4温、湿度控制值及上、下限:可以由用户根据需要设定。
1.5打印记录定时范围:0---999秒可设定。
1.6循环定时器定时范围:工作时间0---9.9分钟、停止时间0---9.9分钟。
1.7上位机通信定时范围:0---9.9分钟。
1.8上限工作延时设定范围:0---9.9分钟。
1.9控温输出功率:电压220V±10%AC、电流5A;控湿输出功率:电流3A;风机输出功率:电流1A。
1.10仪表工作环境条件:0℃---±45℃,相对湿度不大于85%。
1.11仪表工作电压:220V±10%;仪表功耗:<6瓦。
1.12温、湿度传感器:(智能型)1.13仪表安装开空尺寸:1 50×75(mm)。
1.14仪表外形尺寸:160×80×170(mm)。
1.15仪表重量:<1kg1.16打印机:(可扩展)二、工作原理本仪表将干、湿温传感器的等效信号转成相应的数字信号,再由微处理器进行处理后显示和智能控制。
(用户如需定时打印温度和湿度,仪表可扩展时钟和打印机接口。
扩展后,仪表能根据设定的打印时间,定时打印“年、月、日、时、分”和当时的温度、湿度。
使用时应把仪表后面板标有打印机接口(R、T)字样的两个接线端与打印机后面板对应的接线端相连,并把220V交流电源接到打印机后面板标有相,中的接线端。
OYO9226S冷热冲击箱控制器用户设置操作手册
可编程触摸屏温湿度控制器OYO9226S用户操作说明书目录1。
使用说明 (1)1.1 设定操作键盘 (1)1.1。
1 设定值输入键的功能与说明 (1)1。
1.2 设定值输入键盘的类型 (2)1.1。
3 设定按钮及设定值的有效性 (2)1.2 基本运行设定流程图 (2)1。
3 启动画面 (4)1.4 主画面 (4)1.4.1 主画面功能 (4)1.4。
2 状态灯功能说明 (5)1.5 运转显示画面 (6)1.5.1 程式停止画面 (6)1。
5.2 程式运转画面 (7)1。
5.3 监视曲线画面及其属性设定画面 (9)1。
6 运转设定画面 (11)1.6。
1 运转模式选择设定 (11)1.6.2 预约功能的设定画面 (12)1。
6.3 试验终了的设定画面 (12)1。
7程式设定画面 (13)1.8 除霜设定画面 (14)1.8。
1 除霜设定画面 (14)1。
8.2 自动除霜设定画面 (14)1。
9 辅助设定画面 (15)1。
10 报警历史画面 (15)1。
11 文档管理画面 (16)1.12 制造商资料画面 (18)2.内部参数设置说明 (19)2。
1 系统设定画面 (19)2.2传感器温度设定画面 (20)2.2。
1高温箱温度输入设定 (20)2。
2。
2温度可设定范围设定 (21)2.2。
3冷端温度偏差补偿设定 (21)2。
3继电器输出设定画面 (22)2。
3.1继电器输出设定 (22)2。
3.2 SSR输出设定 (24)2。
4压缩机设定画面 (25)2。
5预热区排风设定画面 (27)2。
6待机和除霜设定画面 (27)2。
7 N2GAS和防汗设定画面 (28)2.8 PID设定画面 (29)2.8。
1 PID范围设定 (29)2。
8。
2 PID自动整定 (29)2。
8.3 PID GROUP(PID1~PID6)设定 (31)2.9 图片管理画面 (32)2.9.1 图片管理设定 (32)2。
9.2 图片使用对象设定 (32)2.10异常设定画面 (33)2。
OYO9256P温湿度控制器用户操作说明书
可编程触摸屏温湿度控制器OYO9256P用户操作说明书版本:Ver 2.0目录1 设定按钮 (1)1.1 键盘类型和说明 (1)2 操作界面及说明 (2)2.1 主目录画面 (2)2.2 运转显示画面 (2)2.2.1 运转显示画面一 (2)2.2.2 运转显示画面二 (3)2.2.3 运转显示画面三 (3)2.2.4 曲线参数设定画面 (4)2.3 定值设定画面 (4)2.3.1 定值设定画面一 (4)2.3.2 定值设定画面二 (5)2.4 程式设定画面 (5)2.4.1 程式测试设定画面 (5)2.4.2 程式编辑画面 (5)2.5 运转设定画面 (6)2.5.1 运转设定画面一 (6)2.5.2 运转设定画面二 (6)2.5.3 运转设定画面三 (7)2.6 文档管理画面 (7)2.6.1 历史试验数据文档(磁盘)画面 (7)2.6.2 历史试验数据文档(U盘)画面 (7)2.7 辅助设定画面 (8)2.7.1 辅助设定画面一 (8)2.7.2辅助设定画面二 (8)2.8 报警历史画面 (8)2.9 制造商资料画面 (9)2.9.1 制造商资料画面一 (9)2.9.2 制造商资料画面二 (9)111 操作键盘说明1.1 键盘类型和说明 ● “数字”键盘“数字”键盘提供了“0~9”、“.”和“+/-”字符。
● “数字及字母符号”键盘“数字”键盘提供了“0~9”、“A ~Z ”、“a ~z ”和“SP ”、“-”字符。
“上翻”和“下翻”用于滚动输入按钮。
“切换”用于切换字母大小字及字符。
● “确认及取消”键盘“确认”将执行用户选择将执行之功能。
“取消”将不执行用户选择将执行之功能。
● “提示”键盘仅用于向客户提示信息。
▶ 如果“辅助设定一”中“设置锁定”处于“启用”状态,则点击输入项将弹出提示键盘,22 操作界面及说明2.1 主目录画面2.2 运转显示画面2.2.1 运转显示画面一32.2.2 运转显示画面二2.2.3 运转显示画面三42.2.4 曲线参数设定画面注:数据记录周期、数据磁盘备份的修改将影响曲线数据的保存和备份。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
可编程触摸屏温湿度控制器
OYO9256P
用户操作说明书
版本:Ver 2.0
目录
1 设定按钮 (1)
1.1 键盘类型和说明 (1)
2 操作界面及说明 (2)
2.1 主目录画面 (2)
2.2 运转显示画面 (2)
2.2.1 运转显示画面一 (2)
2.2.2 运转显示画面二 (3)
2.2.3 运转显示画面三 (3)
2.2.4 曲线参数设定画面 (4)
2.3 定值设定画面 (4)
2.3.1 定值设定画面一 (4)
2.3.2 定值设定画面二 (5)
2.4 程式设定画面 (5)
2.4.1 程式测试设定画面 (5)
2.4.2 程式编辑画面 (5)
2.5 运转设定画面 (6)
2.5.1 运转设定画面一 (6)
2.5.2 运转设定画面二 (6)
2.5.3 运转设定画面三 (7)
2.6 文档管理画面 (7)
2.6.1 历史试验数据文档(磁盘)画面 (7)
2.6.2 历史试验数据文档(U盘)画面 (7)
2.7 辅助设定画面 (8)
2.7.1 辅助设定画面一 (8)
2.7.2辅助设定画面二 (8)
2.8 报警历史画面 (8)
2.9 制造商资料画面 (9)
2.9.1 制造商资料画面一 (9)
2.9.2 制造商资料画面二 (9)
1
1
1 操作键盘说明
1.1 键盘类型和说明 ● “数字”键盘
“数字”键盘提供了“0~9”、“.”和“+/-”字符。
● “数字及字母符号”键盘
“数字”键盘提供了“0~9”、“A ~Z ”、“a ~z ”和“SP ”、“-”字符。
“上翻”和“下翻”用于滚动输入按钮。
“切换”用于切换字母大小字及字符。
● “确认及取消”键盘
“确认”将执行用户选择将执行之功能。
“取消”将不执行用户选择将执行之功能。
● “提示”键盘
仅用于向客户提示信息。
▶ 如果“辅助设定一”中“设置锁定”处于“启用”状态,则点击输入项将弹出提示键盘,
2
2 操作界面及说明
2.1 主目录画面
2.2 运转显示画面
2.2.1 运转显示画面一
3
2.2.2 运转显示画面二
2.2.3 运转显示画面三
4
2.2.4 曲线参数设定画面
注:数据记录周期、数据磁盘备份的修改将影响曲线数据的保存和备份。
请在设置完毕后再开始运行。
2.3 定值设定画面 2.
3.1 定值设定画面一
5
2.3.2 定值设定画面二
2.4 程式设定画面
2.4.1 程式测试设定画面
2.4.2 程式编辑画面
6
注:1. 总共有120个程式,每个程式有120个段。
2. 一般情况下,每个测试点需要设定两个相同段的参数。
由于温度和湿度均为大滞后量,随时间之变化量较小,故需要设置一个段来做为过渡。
例如测试点为60℃,85%,测试时间为72小时,当前温度和湿度为25℃,50%。
可以这样设定段参数:SEG001,温度设定为60℃,湿度设定为85%,时间为0.30;SEG002,温度设定为60℃,湿度设定为85%,时间为72.00。
SEG001我们称之为过渡段,实现从(25℃,50%)到(60℃,85%)的过渡,过渡时间为30分钟(该过渡时间可以自己指定,但必须与设备的升降温匹配)。
SEG002为真正做测试的时间,总共为72小时。
2.5 运转设定画面
2.5.1 运转设定画面一
2.5.2 运转设定画面二
7
2.5.3 运转设定画面三
2.6 文档管理画面
2.6.1
历史试验数据文档(磁盘)画面
2.6.2 历史试验数据文档(
U 盘)画面
与“历史试验数据文档(磁盘)画面:类似,请参考之。
8
2.7 辅助设定画面
2.7.1 辅助设定画面一
2.7.2 辅助设定画面二
2.8 报警历史画面
9 2.9 制造商资料画面
2.9.1 制造商资料画面一
2.9.2 制造商资料画面二。