TLYZK智能照明控制器说明书

合集下载

智能灯泡控制器说明书

智能灯泡控制器说明书

Dimmer and Bulb CompatibilityWith the wide variety of bulbs now available on the market it is important to choose a dimmer wisely since not all dimmers are designed to control all types of bulbs. Pairing dimmers and bulbs which are incompatible can result in lights flickering and fluttering, limited dimming range, slow start-up, and inconsistent illumina-tion. To avoid these types of issues it is important to know the features of the types of dimmers available and compare them to your needs and the type of bulb you wish to use.Dimmer Type When to UseUniversal Universal Dimmers are designed to control incandescent, halogen, dimmable LEDand dimmable CFL bulbs. They offer full-range dimming, smooth start-up, and eliminateflickering and fluttering of lights. When using LED or CFL bulbs with a dimmer, be surethat the packaging on the bulb indicates that it is DIMMABLE. Most dimmer and bulbmanufacturers provide bulb compatibility information on their websites that can bereferenced to ensure that the brand/type of dimmer chosen will function properlywith the bulb selected.Incandescent/Halogen Incandescent/Halogen Dimmers are designed to control incandescent and halogenbulbs. They are not designed to control LED and CFL bulbs nor dimmable LED andCFL bulbs and using them to do so may result in inconsistent or limited performance.Additionally, incandescent dimmers are not safety listed with Underwriters Laboratories(UL) to control LED and CFL bulbs nor dimmable LED and CFL bulbs.Electronic Low Voltage Dimmer (EL V)EL V Dimmers control electronic low voltage transformers (EL Vs) and dimmable LED power supplies such as those found in EL V track lighting, under cabinet lighting and LED strips. EL V Dimmers require a neutral wire for installation.Magnetic Low Voltage Dimmer (ML V)ML V Dimmers are suitable for recessed lights which are most often magnetic low voltage. Magnetic low voltage lights tend to be larger and heavier than electronic low voltage.Fluorescent Fluorescent Dimmers control only fluorescent fixtures that incorporate rapid startfluorescent lamps and dimming ballasts.High Wattage Dimmers Dimming devices specifically designed to control high wattage lighting, generally1000W. It is recommended, however, that a 1000W dimmer be used to control anylighting exceeding 600W. This would include large chandeliers or recessed lightingthat controls multiple bulbs with total wattage exceeding 600W.Dimming Sensor This innovative device combines the lighting level control of a dimmer with the energysavings and convenience of a motion sensor. It is compatible with dimmable LED,dimmable CFL, incandescent and halogen bulbs.Control one light from one location.and another location at the top of the stairs. dimming via remote.F AQs* Energy savings may vary.Relative Light Output(% Dimmed)75W Incandescent(Wattage)26W CFL (Wattage)17W LED (Wattage)100%75W 26W 17W 75%63W 18W 12W 50%51W 13W 7W 20%34W7W3WWhy should I consider using a dimmer?Dimmers provide three basic benefits. They create ambiance by giving the user the ability to adjust light levels appropriate to the activity, they reduce energy consumption for greener living and, based upon reduced energy consumption, help lower electric bills.Can I replace a standard wall switch with a dimmer?Yes. A dimmer easily replaces a standard wall switch.How do I know what type of dimmer to buy?You can select a dimmer based upon the fixture or the type of light source you wish to control. Dimmer switches are generally used for ceiling mounted fixtures. They come in a variety of styles including traditional rotary and contemporary slide models. Tabletop, cord dimmers and socket dimmers are used for plug-in lamps.How many watts can a dimmer handle?Dimmers come in various models which are designed to control different wattage levels and loads. The most common ratings are 600W and 1000W Incandescent Dimmers. Some models will have alternate load ratings, for example 150W LED or CFL. You should select a dimmer based upon your wattage requirements. The easiest way to do this is to add up the total wattage of the bulbs you wish to control. For example, a fixture with four 60W bulbs has a total wattage of 240. You can use a 600W dimmer to control this.It is advisable to use only one type of bulb – combining different bulb types, for example incandescent with LED, may result in diminished performance.What is a Universal Dimmer?Universal Dimmers are designed to control incandescent, dimmable LED and dimmable CFL bulbs. They offer full-range dim-ming, smooth start-up, and eliminate flickering and fluttering of lights.How does a Universal Dimmer differ from an Incandescent Dimmer?Incandescent Dimmers are designed to control incandescent bulbs. Unlike Universal Dimmers, they are not designed to control LED and CFL bulbs and using them to do so may result in inconsistent or limited performance. Additionally, incandescent dim-mers are not safety listed with Underwriters Laboratories (UL) to control LED and CFL bulbs.What are the benefits of using a Universal LED/CFL compatible dimmer?The benefits of using this dimmer include smooth operation for precise dimming, low level starting and flicker-free operation when used with incandescent and dimmable LED/CFL bulbs. It is designed to provide optimized performance when used on dimmable LED or dimmable CFL bulbs. Even if you are currently using Incandescent bulbs, you can future proof by installing the Universal Dimmer to ensure compatibility in the future with dimmable LED/CFL bulbs. For quality assurance, in addition to performance, the Universal Dimmers have been evaluated and approved by UL specifically for dimmable LED and dimmable CFL bulbs.What types of bulbs can be used with Universal Dimmers?Dimmable LEDs, dimmable CFLs, incandescent and halogen bulbs are all compatible with the Universal Dimmers. It is recom-mended that only LED and CFL bulbs that are labeled as DIMMABLE be used with Universal Dimmers. The packaging on the bulb should identify it as dimmable.Will I save energy if I dim LED and CFL bulbs?Yes, dimming any bulb reduces energy consumption and is the perfect way to set the ambiance for any occasion. Below is an example of the energy savings* realized when you dim incandescent, dimmable CFL or dimmable LED bulbs.All trademarks are the property of their respective owners.。

智能led照明控制系统设计说明书

智能led照明控制系统设计说明书

(此文档为word格式,下载后您可任意编辑修改!)目录1.引言 (2)2.方案论证 (3)2.1方案一 (4)2.2方案二 (5)2.3各方案的比较 (6)3.各电路设计和论证 (6)3.1 电源电路的方案设计与论证 (6)3.2信号采集部分电路的设计和论证 (7)3.3单片机部分电路的设计和论证 (11)3.4输出部分电路的设计和论证 (14)4. 软件设计 (15)4.1程序流程 (15)4.1.1系统主程序流程图 (15)4.1.2传感器子程序流程图 (16)4.2程序 (17)4.2.1主程序 (17)4.2.2定时器中断子程序 (18)4.2.3数据处理程序 (19)4.2.4 ADC0809连续对2个通道采样程序 (19)5.软硬件系统的调试 (19)5.1硬件调试 (19)5.2软件调试 (20)6.附录 (21)7.参考文献 (22)高亮度LED楼道照明灯电路的设计摘要:本系统以单片机80C51为核心部件,利用光线度检测技术、光电传感器接收技术并配合一套独特的软件算法实现了路灯自动开关、声光控制电路等功能。

在系统设计过程中,联系实际路灯状况,力求硬件线路简单,元件价格经济,充分发挥软件编程方便灵活的特点,来满足系统设计要求。

关键词:单片机、光明二极管、话筒、A/D转换器、传感器。

1.引言随着电子技术的迅猛发展,单片机技术已渗透到航天、国防、工业。

农业、日常生活等各个领域,成为当今世界科技现代化不可缺少的重要工具和强有力武器。

用单片机研制的各个智能化测量控制仪表周期短、成本低,在一起、仪表与机电一体化产品的设计中具有明显的优势。

这次用单片机设计制作一个走廊路灯控制系统。

光控电路有着广泛的应用。

比如城市中的路灯或楼道照明等一般都是由人工操作的,如果采用光控电路,根据光线的强弱来自动开启和关闭照明灯,做到无人自动控制,可以减轻工人的劳动强度,有效的节约能源。

但光控电路有其缺陷,就是夜晚无光线的时候,照明灯将一直工作着,这样会造成资源的浪费,也会缩短照明灯的寿命。

智能的照明控制器使用说明书

智能的照明控制器使用说明书

SY360L智能照明控制器使用说明概述1.1控制器特点●支持远程遥控、消防联动、经纬时控、传统时控、间隔控制、光控。

●大屏幕LCD中文显示界面,功能丰富、操作方便、人机界面友好。

●有4-60回路可供选择●每路4个时间段设置。

●支持手动控制,方便现场调试。

●具备RS485通讯接口,应用Modbus通讯协议,可实现与电脑通讯进行远程操作。

●接线简单,维护方便。

1.2技术指标产品型号:SY360L供电电源:AC 220V电源消耗:< 3W使用环境:温度-40~85℃湿度< 90%接点输出:可扩至60回路光感输入:光敏电阻通讯方式:Modbus标准接口RS485安装方式:显示屏:面板开孔嵌入式、模块:导轨式安装外形尺寸:显示屏:162(长)×100(宽)×45(深)模块:115(长)×90(宽)×40(深)面板开孔:156×92注:单位mm页面选择:在主画面里,按‘’键,进入页面选择画面,输入要打开的页面编号,按‘’键,如果该编号页面存在,则进入该页面,否则返回主画面,页面编号分配如下列表:主画面上显示当前日期和时间,分别显示各回路的路灯开关状态,用图形表示出来,直观明了。

显示当地当天的天亮天黑时间,给用户在设定经纬度时间控制时带来方便。

操作注意事项:控制器在投入使用前,先设定日期和时间、当地的经度和纬度,这样,控制器才准确地计算当地的天亮天黑时间。

请参照全国的经纬度时区表,有不明之处,请与广州新威厂家联系。

操作步骤:移动光标到目标,按‘^’‘ˇ’键修改数值,移动光标保存结果。

注:修改完必须移动光标进行数值保存,如果直接按‘SET’返回主画面,则刚才修改的值会失效。

注:手动开关说明主画面上按才起作用,A、B、C、D分别是控制对应回路灯光的手动按钮。

在开灯的情况下,按住“﹥”和“A”或“B”或“C”或“D”按键为关灯,关灯后,自动开灯时间条件达到,或者光控开灯条件达到时,自动接通亮灯。

无线智能照明控制系统使用说明书

无线智能照明控制系统使用说明书

无线智能照明控制系统使用说明书目录特别注意事项 (1)一、总体介绍 (1)二、产品型号 (2)三、功能特点 (2)四、触摸开关使用说明 (3)4.1 正面功能 (3)4.2 背面功能 (3)4.3 安装步骤 (4)4.4 使用说明 (5)4.5 技术指标 (5)五、情景面板使用说明 (5)5.1 正面功能 (6)5.2 背面功能 (6)5.3 安装步骤 (6)5.4 情景面板学习 (6)5.4.1 清码学习 (7)5.4.2 一个触摸开关学习 (7)5.4.2.1 单路学习 (7)5.4.2.2 两路学习 (7)5.4.2.3 三路学习 (8)5.4.3 两个触摸开关学习 (8)5.4.4 三个触摸开关学习 (8)5.4.5 三个以上触摸开关学习 (9)5.5 技术指标 (9)六、智能无线遥控器使用说明 (9)6.1 功能说明 (10)6.2 无线遥控器学习 (10)6.2.2 主功能控制学习 (11)6.2.2.1 “0~9”按键学习 (11)6.2.2.2 总开学习 (11)6.2.2.2 总关学习 (11)6.2.3 场景控制学习 (12)6.3 特殊功能控制 (12)6.4 技术指标 (13)七、常见问题解答 (13)八、售后服务保证 (16)非常感谢您选购“闽冠”无线智能照明控制系统系列产品,本产品适用于家居、办公室、商场、酒店、学校、医院、仓库等需要灯具照明控制的场所。

本产品依据国际电工惯例,采用先进的电子线路设计,产品性能更稳定,质量更可靠。

为了确保产品的正常使用,请在安装使用之前认真阅读下面操作说明。

特别注意事项1、严禁直接将零线和火线同时接入触摸开关。

2、严禁将超过250V的电压接入触摸开关。

3、本产品不具备防水功能,请保持产品干燥;4、非专业人士请不要自行拆装,否则后果自负;5、请不要长按本产品触摸面板,这样会造成对码数据被清除。

6、安装遥控器电池请注意极性:金属片为正极(+),弹簧为负极(-),电池装反会损坏遥控器。

智能照明管理系统使用说明书

智能照明管理系统使用说明书

保密级别:秘密机密绝密资料编号:WEDO_DES_1000版本:V4.0智能照明管理系统使用说明书编制:会签:审核:批准:电气科技有限公司2020年2月目录1系统概述 (3)2系统运行 (3)3在线监控 (4)4情景管理 (4)4.1情景选择 (4)4.2情景配置 (5)5时控配置 (6)6照明统计 (6)7报警管理 (7)7.1实时报警 (7)7.2历史报警 (8)8通讯管理 (9)9用户管理 (10)10用户登陆 (12)1系统概述智能照明控制是基于计算机技术、自动控制、网络通信、现场总线,嵌入式软件等多方面技术组成的分布式控制管理系统,来实现照明设备智能化集中管理和控制,具有定时控制、联动控制、情景模式、远程控制等功能,控制方式智能灵活、从而达到良好的节能效果、有效延长灯具的寿命、管理维护方便、改善工作环境和提高工作效率;为现代化智能照明行业提供科学管理水平、节能减排、精简人员、节省运营成本和提高服务质量的一套完整信息化建设及智能控制的系统解决方案。

2系统运行双击电脑桌面上的快捷方式图标:,启动系统程序;默认进入系统默认主界面。

当进入主界面后,可点击左侧菜单,可以看到各照明设备点分布状况及开关状态。

如:展厅、一层大厅、二层楼面等。

3在线监控该功能模块为管理人员以列表的方式提供实时在线监控,进入在线监控界面,可以查看变量的实时值,点击左侧节点下的某一个设备,显示该设备所有变量的实时值、采集时间、状态,而且可以对照明设备进行遥控。

4情景管理4.1情景选择该模块为管理人员提供不同的情景模式,管理人员可以根据自己的需要来选择情景模式。

4.2情景配置管理人员可以在此模块中自行设计不同的情景模式。

操作:⏹右击场景列表节点,可以添加场景。

⏹点击场景列表下的场景节点,可以查看场景节点下的设备,右击场景节点,可以修改场景、删除场景、添加虚拟设备。

⏹点击设备列表下的设备节点,勾选要添加的设备,然后勾选要添加到的场景模式,就可以将设备添加到相应的场景中,缺省为设备下的所有变量。

LINETIK 照明管理系统操作手册说明书

LINETIK 照明管理系统操作手册说明书

LINETIKOperating manualLINETIK lighting managementThe desired value for the illuminance can be changed and the constant light control activated/ deactivated using the remote control.The run-on time can be adjusted and the presence detection can be deactivated using the remote control.The lockout can be activated/deactivate d and switching between completely automatic and semi-automatic can be performed using the remote control.To ensure optimal functioning of the system, ensure that the sensors areallocated to the work area when setting up the luminaire .Functions of LINETIKThe functions of LINETIK lighting management guarantee high comfort at the workplace and can significantly reduce the energy consumption.Constant light regulationThe constant light control of the LINETIK lighting management automatically adapts the lighting to the lighting conditions at the workplace (sunshine, overcast sky, closed Venetian blinds). A brightness sensor compares the illuminance on the work area with an adjustable desired value for this. If illuminance is not sufficient, the lacking light quantity is adjusted upwards. If there is too much light, the luminaire is adjusted downwards. In doing do, the adjustment is performed with a certain inertia to prevent too fast and thus unpleasant change of the illuminance.Motion detectionThe luminaire is switched on and off automatically using the motion detection. A passive infra-red sensor (PIR) monitors the detection range for this(diameter approx. 3.5 m). The luminaire is switched on automatically as soon as any person is located in the detection range. However, if the constant light control registers illuminance above the individually adjustable desired value, the luminaire remains in standby mode. If no person is registered in thedetection range within an adjustable run-on time the luminaire automatically switches to the standby mode.Lockout (Power-up) and AutomaticThe use of the luminaire at switchable power outlets can be optimised using the lockout (power-up). When Lockout is activated (Power-up Off), the luminaire remains in standby mode after any power failure until presence is detected or it is switched on manually. When Lockout is deactivated (Power-up On), the luminaire switches on automatically after any power failure. The LINETIK lighting management enables the completely automaticoperation of luminaries at the workplace without any intervention of the user being necessary. When semi-automatic (PIR off only) is activated, the luminaire is in fact switched off during absence, however switching on the luminaire must be performed manually. As a result, maximum energy saving is possible. Unintended, automatic switching on (e.g. in areas near corridors) is prevented.Luminaire set-upDetection range of the presence detection approx. diameter 3.5 mOperationThe operation of LINETIK is performed using buttons on the luminaire:the desired illuminance level Press and hold key until the desired► To change the direction of the adjustment, release the button and press again and keep pressed .After longer absence (hold time) or after any power failure, the programmed desired value for the constant light control is restored automatically.Status LED in the sensor(flashes green or red)LINETIK lighting management Changing settingsLINETIK can be parametrised using an IR remote control:(Articleshould be ordered separately)Switch-on of the luminaireLINETIK lighting management Questions about LINETIKFor questions about LINETIK Lighting Management, pleasecontact: Zumtobel Lighting INC3300 Route 9WHighlandNY 12528-2630For general information about our products, please refer to our website, or contact the respective contract partner. If you haveany special questions, please contact your sales partner.LINETIK Lighting Management FAQ►Motion sensor does not function→Dim value set too low, luminaire switches off→Brightness in the room too high, luminaire switches off►Light sensor does not function→Automatic mode deactivated►Setting of the dim value→Do not influence or cover the light sensor when setting the dim value►Luminaire switches itself on→Lighting level in the room is below the set brightness value→Motion sensor reacts to detected motion in the room→Motion sensor reacts to a fast change of heat in the room(for example, as well as persons, printers, radiators etc. can also be detected asmotion)►Luminaire does not switch on→Check voltage supply of the luminaire→Check mains adapter of the luminaire→Luminaire or LINETIK Lighting Management defective→Recommendation: Contact Service。

智能照明磁保持模块说明书PDF

智能照明磁保持模块说明书PDF

(4,6,8,10,12)L(Y)-16AP(4,6,8,10,12)L (Y )-20AP 智能时控模块使用说明书智能照明控制模块使用说明书三年质保免费升级快速交货技术支持(4,6,8,10,12)L (Y )-20AP二、技术特性本产品在如下使用环境下可以安全可靠地长时间工作、使用。

A/P 智能照明控制器(以下简称控制器是我公司采用国际先进技术研发的智能照明控制系统。

该控制系统集成消防联动控制、光控控制、就地操控、远程操控。

独创三级队列权限管理、智能化、自动化控制输出管理。

控制器外壳采用高档ABS 阻燃绝缘专用工程塑料,保障控制器安全可靠的使用。

设备安装维护简单,易于操控。

广泛应用于学校、商店大厦,酒店、工厂车间、停车场及地下停车场、小区照明,室外路灯、石油化工,煤矿照明、国家重点办公单位、国防、电信等一切使用人工智能照明的设施设备。

)标称值安全使用值安全使用率使用类别阻性负载容性负载感性负载20A 18%15%15%3.5A3A3A20A 20A 一、产品概述(4,6,8,10,12)L(Y)-16AP三、安装使用本产品安装使用35mm 标准导轨安装,固定35mm 导轨螺丝不得少于两颗,并且固定35mm 导轨必须可靠地固定紧固。

3.1使用环境温度使用环境-10℃∽+45℃,24H 平均温度小于35℃。

安全使用容量的海拔高度小于2000米当发每增加1000米时,输出容量应参照安全使用容量降低15%。

大气相对湿度在空气温度为+45℃时,空气湿度为50%。

较高的温度可以有较高的湿度,但是应该考虑到产品的表面不应该结露。

安装环境适用于建筑物内无导电粉尘,无腐蚀性,无易燃易爆气体。

安装场地任何方位的磁场应该不大于地磁场的3倍。

通信线路避免强磁场干扰。

通信电缆铺设应该与强电要充分分开,使用单独的金属管铺设。

标称值安全使用值安全使用率使用类别阻性负载容性负载感性负载16A 18.5%15%15%3A2.5A2.5A16A 16A四、界面端口通风散热良好。

智能建筑智能照明系统操作手册

智能建筑智能照明系统操作手册

智能建筑智能照明系统操作手册第一章概述 (3)1.1 智能照明系统简介 (3)1.2 智能照明系统组成 (3)2.1 传感器模块:传感器模块主要包括光敏传感器、红外传感器、声音传感器等,用于实时监测环境参数,如光照强度、人体活动、声音等,为系统提供数据支持。

(3)2.2 控制器模块:控制器模块是智能照明系统的核心部分,负责接收传感器模块采集的数据,根据预设的控制策略对数据进行处理,并输出相应的控制信号。

(3)2.3 执行器模块:执行器模块主要包括调光模块、开关模块等,用于实现对照明设备的实时控制,如调节灯光亮度、开关灯光等。

(3)2.4 通信网络模块:通信网络模块负责将各个模块连接起来,实现数据的传输和共享。

常见的通信方式包括有线通信和无线通信。

(3)2.5 用户界面模块:用户界面模块提供用户与系统交互的界面,用户可以通过手机APP、触摸屏等方式对系统进行设置和操作。

(3)2.6 数据处理与分析模块:数据处理与分析模块对采集到的环境数据进行分析和处理,为系统提供决策依据。

(3)2.7 电源模块:电源模块为整个系统提供稳定的电源,保证系统正常运行。

(3)第二章系统安装与调试 (4)2.1 系统安装流程 (4)2.1.1 前期准备 (4)2.1.2 安装步骤 (4)2.2 系统调试方法 (4)2.2.1 单元调试 (4)2.2.2 系统调试 (5)2.3 常见问题处理 (5)第三章系统配置与设置 (5)3.1 系统配置流程 (5)3.1.1 确定系统需求 (5)3.1.2 安装系统环境 (6)3.1.3 配置Web服务器 (6)3.1.4 配置数据库服务器 (6)3.1.5 配置编程语言环境 (6)3.2 系统参数设置 (6)3.2.1 网站参数设置 (6)3.2.2 数据库参数设置 (6)3.2.3 编程语言参数设置 (6)3.3 系统升级与维护 (7)3.3.1 系统升级 (7)3.3.2 系统维护 (7)第四章照明控制 (7)4.1 照明场景设置 (7)4.2 照明亮度调节 (7)4.3 照明定时控制 (8)第五章系统集成 (8)5.1 与智能家居系统的集成 (8)5.2 与楼宇自动化系统的集成 (9)5.3 与安防系统的集成 (9)第六章系统监控与管理 (9)6.1 系统监控界面 (9)6.2 系统故障诊断 (10)6.3 系统运行数据统计 (10)第七章用户操作指南 (11)7.1 系统操作界面 (11)7.1.1 登录界面 (11)7.1.2 主界面 (11)7.1.3 功能模块 (11)7.2 常用操作流程 (11)7.2.1 个人信息管理 (11)7.2.2 数据查询 (12)7.2.3 业务办理 (12)7.2.4 系统设置 (12)7.3 用户权限管理 (12)7.3.1 权限分配 (12)7.3.2 角色管理 (12)7.3.3 用户组管理 (12)7.3.4 权限控制 (12)第八章系统维护与保养 (12)8.1 系统日常维护 (12)8.2 系统故障处理 (13)8.3 系统保养周期 (13)第九章系统安全与防护 (13)9.1 系统安全措施 (13)9.2 系统防护措施 (14)9.3 系统应急处理 (14)第十章系统节能与环保 (14)10.1 节能措施 (15)10.1.1 智能低压配电系统 (15)10.1.2 地源热泵系统 (15)10.2 环保措施 (15)10.2.1 新风系统 (15)10.2.2 环保型建筑材料 (15)10.3 节能效果评估 (15)第十一章系统应用案例 (16)11.1 智能家居照明应用 (16)11.2 楼宇照明应用 (16)11.3 公共场所照明应用 (17)第十二章常见问题解答与售后服务 (17)12.1 常见问题解答 (17)12.2 售后服务流程 (17)12.3 客户投诉与反馈处理 (18)第一章概述1.1 智能照明系统简介科技的不断发展和人们生活品质的提高,智能照明系统逐渐成为现代建筑中不可或缺的一部分。

智能LED路灯控制系统操作说明2

智能LED路灯控制系统操作说明2

智能LED 路灯控制系统操作说明
1. 集中控制器连接方式:
2. 打开电源开关
3. 设置IP 地址
打到ON 状态
220V AC L 线接8# N 线接10#
网线接口
GPRS 模块
注意手机卡方向
检查并确认发送和收到数据即可
4. 电脑主机插入网线后,先打开IE 浏览器,在双击路灯监控系统软件,此软件打开后图标会缩小到右下角!
5. 输入密码 “123456”点击登录
1.双击打开IE
2.双击打开软件
3.再次双击打开
6. 进入控制软件界面,如果未连接成功检查是否有发送和收到数据,接着点刷新。

123456
2点击管理下的日志
3点击查询
4集中控制器连通
5刷新
7 集中控制器复位-----下发------配置
3下发
5配置成功
2复位
4配置
1点击1次
查询
2 (8台电源配置成功)
8. 巡测功能说明 每次命令间隔为2分钟 开灯—关灯----开灯---100%--75%--50%---25% 结束
9. 灯具故障反馈:先点击LED 组1在巡测到调光状态时将灯具编号1504防水头拔除,会出现报警声音及图标显示
红色,在次将防水头插好,报警声音消除,红色图标变为绿色!
1点击回到主界面
2点击选中集中控制器
3.点击调光
4.调到20级点击发送。

易成智能走廊灯自动调光器说明书

易成智能走廊灯自动调光器说明书

Selected Programmable ParametersPOWER UP Options: On/Off Sets the status of luminaires when power is applied. On - lights power-up on irrespective of occupancy. Off - lights respond to occupancy after 15 seconds. Pre-set - OnMOVEMENT DETECTOR OPERATIONOptions: Auto/Semi-auto Note: Only affects switched-live output, R1 (R2 is always fully automatic).Auto - lights switch on and off automatically. Semi-auto - lights are switched on by wall switch or hand-held controller and switch off automatically. Pre-set - Auto OFF DELAY 1 minute - 96 hours Sets the period after the last observed movement when the lights switch off. (In walk-test mode, the Off Delay is 10 seconds.) Pre-set - 20 mins(SENSITIVITY) RANGE WHEN LIGHTS ON/LIGHTS OFFOptions: 12 levels Occupied (i.e. Lights On): Max, High, Med, LowUnoccupied: (i.e. Lights Off): can reduce to a percentage of the ‘Occupied’ Range, improving immunity to nuisance triggering. Pre-set - HIGH/75%PHOTOCELL Options: Active/Passive/Disabled Passive - holds lights off when sufficient natural light. Active - lights turn on and off as required when natural light levels fluctuate and area is occupied. Disabled - the photocell has no effect. Pre-set - Disabled 24 HOUR CYCLE Options: Yes/No For use in ‘Washroom Mode’ only. Provides hygiene flush if area has been unoccupied for 24 hours. Pre-set - NoThe Gold Series LightSpot is part of a comprehensive range of presence detection systems designed to control modular luminaires with high frequency ballasts and other fixed-output lighting loads.Gold LightSpot offers superior-performance, programmable presence detection for lighting control in offices including open-plan areas. It uses microwave presence detection technology which enables the range and sensitivity to be adjusted to ensure a tailored detection pattern to suit any application. It is a dual-circuit control and is available for flush and surface mounting.Gold LightSpot offers the following features:LightSpot - Stand-alone lighting control by presence detection and photocellGold Series LightSpotActive presence detection by microwave technology.Passive photocell holds lights off in ambient conditions. Active photocell has the capability to switch lights off in occupied areas.Off delay - period following the last observedmovement after which the lights switch off (selectable via QuickSet Pro).Detection pattern and range in metres under normaloperating conditions.Switched Live influenced by photocell and occupancy; volt-free output by occupancy only. Independent time delays can be programmed via QuickSet Pro.Hand-held Controller provides local user override.Remote programming ensures changes can be easily accommodated.Washroom mode. If no movement is detected in a 24-hour period, detector can be programmed to switch the load on for the duration of the off delay. Can operate as a urinal control when used with an SV3 solenoid valve unit.Gold Series LightSpot T echnical Data Sheet D4072 Rev. H 14-Jul-2020 Page 1Gold Series LightSpot detectors are extremely sensitive to movement; they must be mounted on a solid surface which has no movement whatsoever.As these detectors use microwave technology to detect movement they are not recommended for applications where there are large surface areas of metal, e.g. metal ceiling or floor tiles, as unpredictable sensitivity may result.Also, note that these detectors are capable of detecting large moving metal objects well beyond the normal range at which they are sensitive to human targets.The units are colour coded (blue, yellow, red or green) according to four variations in operating frequency. T o ensure reliable operation, it is essential that units of the same colour code do not occupy adjacent positions in open-plan areas.Installation and Commissioning NotesSurface versionThe housing may be secured to a hard surface or a BESA box. The unit fits into the sinking box with a simple bayonet action thus concealing the fixing screws.Flush versionDepth required behind ceiling: 62mm from front flange plus an allowance for the minimum bend radius of the cable. Sinking box fits into 89mm diameter hole in ceiling tile or plasterboard ceiling. T o avoid damage to ceiling tile, do not overtighten. No access above the ceiling is necessary.Note :Do not mount within 25cm of a luminaire.Do not position this product on a pitch narrower than 5m.Page 2 Gold Series LightSpot T echnical Data Sheet D4072 Rev. H 14-Jul-2020Part Numbers MS2421PF Dual-circuit Gold LightSpot with photocell - flushMS2421PSM Dual-circuit Gold LightSpot with photocell - surface mounted QUICKSET PRO QuickSet Pro Digital 2-Way ProgrammerHC5A Universal Hand-held Controller c/w wall bracketSV3 WRAS-Approved Solenoid Valve - 15mm compression fittingsQuickSet Pro Digital 2-Way ProgrammerMenu-driven LCD Programmer with automatic equipment recognition and parameter download facilities.HC5A Universal Hand-held ControllerAllows manual override. Supplied with wall bracket.Ancillary ItemsOPERATING VOLTAGE: 230V 50-60 HzPRODUCT RATING & RECOMMENDED CIRCUIT PROTECTION: 10 Amps MAXIMUM RECOMMENDED LOAD: 10 Amps per output (not exceeding 10A in total)2TERMINAL CAPACITY: 2 x 2.5mm PHOTOCELL: Adjustable 0-5000 lux (with a 20% reflective work plane)OFF DELAY: 1 minute - 96 hoursRANGE: Approx 7m dia at 2.4m ceiling heightMAXIMUM RECOMMENDED MOUNTING HEIGHT : 3.0m COLOUR: WhiteMATERIAL: Flame retardant PC/ABSWEIGHT : 243g (flush version), 251g (surface version)IP RATING: 2Xo o OPERATING TEMPERATURE: 0C to 40CEx-Or operates a genuine policy of continuous improvement. You may expect the specification to be regularly enhanced. For latest technical information, please visit Technical DataGold Series LightSpot T echnical Data Sheet D4072 Rev. H 14-Jul-2020 Page 3Please check to ensure this is the most recent issueD4072 Rev. H 14-Jul-2020Gold Series LightSpot T echnical Data Sheet Page 4。

KTV智能灯控调试软件使用说明

KTV智能灯控调试软件使用说明

KTV智能灯控调试软件使用说明一、软件的安装运行软件程序,将KTV智能灯光控制系统软件安装到你指定的目录。

参考软件安装说明文档。

打开程序软件;二、硬件的连接1、用USB线连接电脑和USB调试盒。

2、使用配备的网线连接USB调试盒的DMX输出口和智能灯控的DMX输入口。

3、218型灯控DMX输入口插入网线后自动进入调试模式。

4、在智能灯控上长按“确认”键3秒进入学习模式,或者2秒内短按“确认”键5次后再短按“下翻”键同样也可以进入学习模式。

三、软件操作说明1、打开调试软件,软件会提示进行通讯参数设置,选取到连接USB调试盒的串口号,设置通讯波特率为115200, 点击打开串口后返回。

智能灯控会短鸣叫一声进入PC模式,显示屏上显示-PC-。

这时就可以打开软件主界面。

2、场景编辑功能。

在软件菜单里选择文件——新建,新建一个场景列表。

输入你想要保存的文件名称,点确定后会自动新建一个场景,或者选择想要保存到硬盘的目录再输入文件名。

鼠标双击该场景弹出场景参数修改对话框此时你可以修改场景的名称如“动感场景”并设置软件播放的每步停留时间,以25ms为单位。

确定后退回到DMX模拟控台主界面。

点左侧按钮增加一个新场景,点左侧按钮插入一个新场景,点左侧按钮删除选定的场景;点右侧按钮增加一个新步数,点右侧按钮插入一个新步数,点右侧按钮删除选定的步数;点左侧的复制按钮会将选中的一个场景复制到粘贴板,此时粘贴按钮会亮起。

然后你可以新建一个场景并选中后点粘贴,将复制的内容完全粘贴过来,你可再修改场景名称。

拉动下方的DMX模拟推杆,设置每步每个通道(最多512个通道)的数值。

完成后点保存按钮保存当前的场景列表文件。

方便下次打开调用。

如何将其他场景列表文件中的场景数据复制到另一个场景文件中:1、打开你需要复制数据的场景文件,选中你要复制的场景,点复制按钮;2、关闭当前的场景,打开你另一个场景文件;3、选中一个场景(不要的或新建的),点粘贴按钮就可以将复制的数据粘贴过来。

萤石 智能照明-调光控制器 CS-HAL-LC1 使用说明书

萤石 智能照明-调光控制器 CS-HAL-LC1 使用说明书

萤石LC1用户指南使用产品前请仔细阅读用户指南目录装箱清单 ������������������������������������������������������������3外观介绍 ������������������������������������������������������������4配置流程概览 �����������������������������������������������������5下载“萤石云视频” ������������������������������������������5安装设备 ������������������������������������������������������������6添加至“萤石云视频” ���������������������������������������7参数信息 ������������������������������������������������������������9售后服务支持 ���������������������������������������������������10上门安装服务 �����������������������������������������������������������������������������10声明 ������������������������������������������������������������������������������������������10版权声明 ����������������������������������������������������������11装箱清单使用“萤石云视频”客户端扫描该二维码可快速添加设备使用其它工具(例如微信、浏览器等)扫描该二维码可查看详细用户指南设备 x1用户指南 x1文中所有图片仅供参考,请以实物为准。

智能照明控制模块说明书

智能照明控制模块说明书

一、产品应用领域产品广泛应用于商厦、学校、医院、公园、体育馆、展览馆、工业园区、机场、铁路、车站、变电站等地的灯光控制、消防联动、能耗监测和节能管控二、功能特点1. 1-12路继电器开关输出单元2. 自带场景控制器,多达128个场景3. 每个回路具有灯具保护延时(0-60分钟)4. 每个回路具有分批开启延时(0-25秒)5. 继电器开关可手动控制6. 具有远程编程和管理功能7.自带两路开关量输入,消防,自检反馈,电流检测等功能8. 设备重启可选择已开的场景或指定的场景三、安装连接1.安装条件安装位置要通风良好,注意防潮、防震、防尘。

2. 建筑照明智能化管控系统,采用分层、分区或结构,每个区域采用总线结构,可连接40-50个模块。

区域与中心干线采用10M/100M以太网通讯方式,通过IP网关或Wifi链接有效提高整个系统得数据交换速率。

通讯总线采用RVVP2*2*0.75、RVVP2*2*1.0、RVVP2*2*1.2(根据总线上元件的数量、通信线路长度确定)屏蔽双绞线将各种模块手拉手的并接在总线上,任何模块的损坏不会影响到其他模块的正常运行,安装、维修和更换极为简便。

3.中心通过软件程序,对总线上的各种模块进行编程,可关联总线上任意模块之间的控制关系,只需少量的程序调整,即可实现业主的实际照明要求。

模块采用35mm导轨安装,智能面板采用标准86底盒安装。

l四、MOT型系列智能灯光控制器接线图说明1、输出控制常开触点AC250V/16A(注:负载接线示意图)2、运行和通信状态指示。

3、手动控制开关,现场实验按钮。

4、工作电源:V+,V-:DC12V;VCC,GND:DC12V/ 2A;电源和智能照明模块对应V+连接VCC,V-连接GND,B0,A0,RS-485通信接口,主要与后台总线连接,智能照明控制模块BO,A0之间对应手拉手方式连接,KEY为开关量连接信号或消防接口,B1,A1为抄表连接信号,DS1为温度采集连接信号,I1,I2干接点输入根据现场编程设定五、MOT型系列智能灯光控制器选型▲设计及选型说明1.中心根据实际需要的照明场景,通过编程软件,对总线上的各个模块进行控制关系、照明场景的编程,实现照明智能化控制及照明能源的合理分配及利用。

智能灯控制系统说明书

智能灯控制系统说明书

Product features
Ÿ ZigBee automatic networking technology, no need to pair codes, easy to use
Ÿ Compatible with most V+signal strip lights and panel lights on market
Cautions
1) Please make sure the circuit is powered off before installation; 2) Please wire it up strictly according to the wiring instruction and make sure the definition of each wire before wiring it up; 3) RGB Box can only connect to V+ control panel light or strip light; 4) The power supply voltage must match the load's rated voltage; 5) This product is designed for dry places. It can’t be used in moist environment like bathroom.
12
Product spec
Model No.:CC10ZW Size:70*70*23mm(L*W*H) Power supply:DC12V&DC24V Max load current:20A Working frequency:2.4GHz Wireless Transmit power:20dBm Static power consumption:<0.1W Wireless receiving sensitivity:≥-90dBm Protocol:ZigBee HA Networking mode:ZigBee automatic networking Encryption:AES128 Distance:no limit Working temperature:-20~60°C Working humidity:≤80%
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档