QB2000F单点壁挂式气体检测报警器
QB2000甲烷报警器

QB2000甲烷检测报警器QB2000甲烷检测报警器产品描述:QB2000甲烷检测报警器由报警监控器和气体探测器等构成,可混合配接多种气体探测器,安装布网方便,实现1~8路物理量和48路数字量的测量、显示和公共报警控制。
QB2000甲烷检测报警器是我公司研制的多点监控气体检测报警控制器,用于检测环境空气中甲烷气体的浓度。
QB2000甲烷检测报警器广泛用于需要防火、防爆、防中毒的场所进行气体安全检测报警。
QB2000甲烷检测报警器采用嵌入式32位微处理器作为控制单元,高精度进口传感器作为检测变送器,灵敏度高,响应速度快。
QB2000甲烷检测报警器功能特点:先进的32位超低功耗嵌入式微控制器128*64点阵液晶显示全中文菜单方便国内用户使用多种气体混合安装探测器故障自动检测报警记录自动存储500条密码管理功能,重要操作需密码验证,有效防止误操作可接1-8个4-20mA和48路RS485信号输出的探测器最多4个报警继电器联动输出,继电器配置可编程QB2000甲烷检测报警器技术参数:容量:1~48只探测器8只4-20mA信号探测器48只RS485信号探测器检测气体:可燃气检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示报警设定:一级浓度报警点程序设定二级浓度报警点程序设定报警提示:超高亮发光报警提示报警方式:声光报警>110分贝报警输出:无源节点,容量AC 220V 3A环境温度:-10°~50°环境湿度:>90%无结露防爆等级:Exd II CT6防护等级:IP44电源:AC220V,50HZ<4W传输距离:<1000m RVVP3*1.5m㎡屏蔽线尺寸重量:25cm*38cm*10cm 3.0kg注释:根据用户需要选配不同功能及配件QB2000检测报警器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。
QB2000氧气检测控制器

QB2000氧气检测控制器QB2000氧气检测控制器产品描述:QB2000氧气检测控制器既可以更换同种类型传感器,也可以更换不同气体种类传感器、不同量程传感器模块,操作和识别自动完成。
QB2000氧气检测控制器无论何种传感器模块插入后,无需标定设置。
探测器自动识别,读取出厂标定数据和相关设置值,自检完成后即刻运行。
QB2000氧气检测控制器新出厂传感器模块更换到老探测器上,即可让探测器具备出厂一样的检测、报警准确性,达到计量等检测要求。
QB2000氧气检测控制器一旦最容易损坏及过期的传感器失效后,通过一体化探测器的方便更换性,客户即可查找解决问题,避免了上门服务的延误和人工费用。
QB2000氧气检测控制器在当环境中氧气浓度达到或超过预置警报值时,报警器立即发出声光报警,以提醒及早采取安全措施,并驱动排风、控制系统,防止发生爆炸、火灾、中毒事故,从而保障安全生产。
QB2000氧气检测控制器功能特点:先进的32位超低功耗嵌入式微控制器128*64点阵液晶显示全中文菜单方便国内用户使用多种气体混合安装探测器故障自动检测报警记录自动存储500条密码管理功能,重要操作需密码验证,有效防止误操作可接1-8个4-20mA和48路RS485信号输出的探测器最多4个报警继电器联动输出,继电器配置可编程QB2000氧气检测控制器技术参数:容量:1~48只探测器8只4-20mA信号探测器48只RS485信号探测器检测气体:氧气检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示报警设定:一级浓度报警点程序设定二级浓度报警点程序设定报警提示:超高亮发光报警提示报警方式:声光报警>110分贝报警输出:无源节点,容量AC 220V 3A环境温度:-10°~50°环境湿度:>90%无结露防爆等级:Exd II CT6防护等级:IP44电源:AC220V,50HZ<4W传输距离:<1000m RVVP3*1.5m㎡屏蔽线尺寸重量:25cm*38cm*10cm 3.0kg注释:根据用户需要选配不同功能及配件QB2000检测控制器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。
QB2000F单点壁挂式一氧化碳检测报警器

QB2000F单点壁挂式一氧化碳检测报警器QB2000F单点壁挂式一氧化碳检测报警器产品描述:QB2000F单点壁挂式一氧化碳检测报警器,是一种固定式可连续检测作业环境中一氧化碳浓度的仪器。
QB2000F单点壁挂式一氧化碳检测报警器为自然扩散方式检测气体浓度,采用进口电化学传感器,具有极好的灵敏度和出色的重复性。
QB2000F单点壁挂式一氧化碳检测报警器大屏幕液晶屏实时显示泄漏气体的浓度值,超过预设报警点立即启动声光报警号或驱动排风系统。
QB2000F单点壁挂式一氧化碳检测报警器仪器采用嵌入式微控制技术,全中文菜单操作简单,便于中国人使用,功能齐全,非常可靠。
QB2000F单点壁挂式一氧化碳检测报警器功能特点:仪器采用先进的32位嵌入式微控制器128*64点阵图形液晶显示用户可自行设置高低报警点全中文菜单方便国内用户使用首次报警时间显示功能具有实时时钟功能自动校准功能,减少测量误差报警记录自动存储200条备用电池非报警状态下可工作2小时以上(用户选配)标准4-20mA信号可直接接入工厂DCS系统(用户选配)RS485数字信号可与工厂上位机连接(用户选配)传感器模块更换后可自动识别,无需重新标定,传感器模块可与我公司模块化探测器通用QB2000F单点壁挂式一氧化碳检测报警器技术参数:测量范围:0-100%LEL显示误差:≤±3%F.S响应时间:T90<30s显示方式:128*64点阵式液晶屏实时显示数据及系统状态报警提示:广角高度发光提示、100dB蜂鸣音随浓度增加频率加大报警点:一级报警用户设定二级报警用户设定报警输出:两路继电器输出,容量AC 220V 2A信号输出:国际标准4-20mA信号可直接接入工厂DCS系统(用户选配)RS485数字信号与工厂上位机连接(用户选配)工作环境:-30°~+50°;湿度<95%RH无结露工作电压:AC 220V 50HZ备用电池供电可连续工作2小时以上(用户选配)防护等级:IP65重量:约1200gQB2000F检测报警器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。
单点壁挂式气体检测报警仪HD1100

南京汇登电子科技有限公司地址:南京市白下区洪武路336号HD1100单点壁挂式气体检测报警器使用说明书南京汇登电子科技有限公司Nanjing Huideng Electronic Technology Co.,Ltd专业是基础服务是保证质量是信誉目录1、使用注意事项 (1)2、概述 (2)3、工作原理 (2)4、技术性能及参数 (3)5、安装说明 (4)6、仪器参数设置说明 (5)7、标定说明 (6)8、常见故障及维修 (7)9、产品成套性 (7)附录、标定记录 (8)附录:标定记录型号:HD1100单点壁挂式气体检测报警器规格:仪器编号:传感器编号:出厂日期:温馨提示在使用仪器前请仔细阅读本说明书1.使用注意事项A.在使用仪器之前,仔细阅读操作手册。
B.本仪器的使用必须按我公司指定的工作规程。
C.我公司负责该产品12个月的保修(保修期从用户拿到仪器之日算起)。
用户在使用中应遵守使用说明,任何由用户操作不妥造成的仪器损坏,不在保修范围之内。
D.在维修仪器和更换部件时必须采用我公司的原装部件,并在本公司授权下由受过专门培训的人员来完成。
如果用户自行修理更换部件,仪器的可靠性责任由操作者负责。
E.传感器内有酸溶液,用户不要拆卸,还要注意不要损坏传感器正面的薄膜。
如果操作不当,传感器内酸液泄漏到皮肤上,应及时用水连续冲洗接触部位10分钟。
F.仪器需每年标定一次;仪器的传感器的隔爆片部位要定期清理(用低压压缩空气吹扫),否则灰尘杂质堵塞防护孔会影响检测的灵敏度。
G.本仪器的使用还应遵守国内有关部门及工厂内仪器管理方面的法令和规则。
2、概述随着工业的迅速发展,人类接触有害气体及易燃易爆气体的场所越来越多,由此造成对人类本身的危害越来越大。
一次次的中毒或爆炸事故,使人们清醒的认识到在发展工业的同时保护人类自身安全的重要性。
因此各种有害气体及易燃易爆气体报警仪器渐渐成为工业安全中必不可少的防护设备。
HD1100单点壁挂式气体检测报警器主要用于工业现场非防爆场合的气体检测报警,该仪器采用进口电化学传感器,准确度高、线性好;具有(4~20)mA电流信号输出、RS485输出功能,便于与其它仪表或控制器连接;配备两路开关量控制信号输出,可控制排风扇、电磁阀等设备。
QB2100柜式控制器 说明书(2)

体报警控制器QB2100型气使用说明书V1.2目录11、产品概述 (3)2、技术指标 (3)3、产品介绍 (4)3、1产品使用 (5)3、2功能设置与操作级别 (7)3、2、1一级菜单操作 (7)3、2、2二级菜单操作 (10)3、2、3三级菜单操作 (11)4、控制器与探测器的链接 (12)4、1控制器尺寸(单位:mm) (12)4、2控制器与探测器的链接 (12)5、配套使用的探测器 (14)5、1技术参数: (14)5、2安装位置: (15)6、产品的维护 (16)6、1注意事项 (16)6、2常见故障的分析与排除 (16)6、3 保修期 (17)21、产品概述QB2100可燃/有毒气体报警控制器,是我公司开发的功能实用,操作方便的可燃/有毒气体报警控制器,可与我公司的可燃/有毒气体探测器共同组成工业用气体报警系统。
控制器亦可通过RS485信号上联至监控中心计算机或图形显示装置。
从而构成远程监控、本地监控、现场监控的多级监控网络,大大提高了监控的实时性、准确性。
该产品采用壁挂式安装,每一个地址对应一个探测器。
通过与探测器的配合使用,并通过控制器单片机对探测器上传的数据进行的各种数据处理,最终完成数据的显示、报警、输出和控制等功能。
本产品的设计、制造及检验均遵循以下国家标准:GB16808-2008 《可燃气体报警控制器》GB12358-2006 《作业场所环境气体检测报警仪通用技术要求》GB15322.1-2003 《测量范围为0~100%LEL的点型可燃气体探测器》2、技术指标安装方式:柜式安装工作电压:主电:220VAC/(50~60)Hz3备电:24VDC/4.6AH(可选)额定功率:≤10W工作温度: 0℃~ + 40℃工作湿度:(10~95)%RH探测器输入:三线制或四线制电源线≥1.5mm2(国标线)信号线≥1.5mm2(双色双绞线)报警方式:声音报警:分故障报警、浓度报警两种不同的声音。
CHK-2000型气体报警控制器说明书

CHK-2000型气体报警控制器说明书产品目录1概述12特点13主要参数14安装14.1安装方式14.2外形尺寸15结构和功能25.1结构25.2功能25.2.1报警显示板25.2.2专线控制板25.2.3打印机25.2.4电源26系统设计与说明36.1系统组成和布线框图36.2系统布线和设计要求3 7现场调试步骤37.1绝缘电阻测量37.2编址单元编址37.3控制器静态测量3 7.4控制器空载通电检测3 7.5编制单元登记37.6联动功能测试38操作使用说明48.1正常监视状态48.2液晶屏亮度调节4 8.3故障48.4火警48.5联动48.6菜单操作48.6.1联动48.6.2设置58.6.2.1日期与时钟58.6.2.2自动登记68.6.2.3手动登记68.6.2.4部件隔离68.6.2.5联动编程68.6.2.6开关打印机6 8.6.2.7控制检测68.6.2.8联动控制方式7 8.6.2.9清除操作78.6.2.10汉字注释输入7 8.6.3查询78.6.3.1登记地址查询7 8.6.3.2隔离地址查询7 8.6.3.3联动编程查询7 8.6.3.4控制检测查询8 8.6.3.5当前故障查询8 8.6.3.6汉字注释查询8 8.6.3.7历史记录88.6.4测试88.6.4.1部件状态信号9 8.6.4.2模拟量曲线98.6.4.3回路信号浏览98.6.4.4地址类型状态98.6.4.5控制器自检99联动逻辑编程语句格式910使用与维护1011运输、储存1012随机附件1013其它101概述CHK-2000型可燃气体报警控制器(以下简称控制器)是我公司为了满足燃气市场的不断发展需求而研制开发的新产品。
它是二总线可燃气体报警控制器,集气体泄漏报警和联动控制于一体,可以与我公司生产的防爆型燃气探测器及各种模块等设备组成智能化的总线型可燃气体报警控制系统。
该系统比较适用于中、小型建筑面积的火情监测和控制。
汉威科技 GTQ-WD 系列 工业及商业用途 点型可燃气体探测器 使用说明书

GTQ-WD系列工业及商业用途点型可燃气体探测器使用说明书(使用产品前请仔细阅读本说明书)产品型号:GTQ-WD2200/WD6200汉威科技集团股份有限公司Hanwei Electronics Group CorporationISO9001/ISO14001/OHSAS18001国际管理体系认证企业Ver:00196感谢您购买汉威科技产品。
当您准备使用本产品时请务必仔细阅读使用说明书,并按照所提供的有关操作步骤进行,以使您能充分享受我公司提供的服务,同时避免因误操作而损坏本机或发生其它意外。
如因人为原因导致设备损坏,将会导致保修条款失效。
汉威科技全权负责本说明书的编制及修订,并尽量确保说明书内容正确无误,同时本公司将保留改进产品和修改说明书而不预先通知的权利。
本说明书中的图片仅用于功能说明,若与实物不符,请以实物为准。
请妥善保管本说明书,以便在您日后需要时能及时查阅、获得帮助。
符号定义在开始使用前,请先熟悉可能出现在本说明书中的符号:注意—可能伤及自己或他人。
小心—可能损坏探测器或其它设备。
备注—注释、使用提示或附加信息。
版权声明本使用说明书版权属汉威科技集团股份有限公司所有,未经书面许可,说明书中的任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段及方式进行传播。
用户服务指引1购买产品后,请根据装箱单仔细核对附件、合格证及产品保修卡等是否齐全,若发现不全,应立即与销售商或厂家联络。
2本产品自售出之日起十二个月内,凡用户遵守贮存、运输及使用要求,而产品质量低于技术指标的,凭产品保修卡享受免费维修。
3如果您对我们提供的产品和服务有任何疑问或不满,包括产品技术、质量、安装维修、服务态度、收费标准等问题,请您及时联络我们,我们将会对您的意见及时进行妥善处理。
安全事项在使用本产品之前,请务必阅读以下安全事项并严格遵守相关操作要求。
1使用前请检查探测器外壳有无裂痕或是否缺少零部件。
ATO SKY2000 气体检测仪用户手册说明书

Pumping Type Gas DetectorSKY2000User ManualWelcome to visit !Email:*************Tel: +1 800-585-1519 (Toll-free)Global Shipping Enabled*** Thanks for purchasing our product. Please read the user manual carefully before using. *** Keys Operation:Turn on/off: long press for 3s to turn on/off the device, short press to confirm or save data.Menu: in detection mode, press this button to enter into parameter setting mode, and in parameter setting mode, press this button to move the cursor.Plus: in parameter setting mode, short press it to select items upward or add value. Long press for 3 seconds to turn on/off alarm function quickly.Minus: in parameter setting mode, short press it to select items downward or decrease value. Long press for 3 seconds to turn on/off air pump quickly.Exit: in parameter setting mode, short press it to go back to previous menu. Long press to shift the gas concentration unit quickly.Power On / OffPut the detector in clean air, and press the “ON/OFF” for three seconds, the detector will be turned on and the pump will start to work. The screen displays the following interface successively: Brand and Logo, main parameter interface, initialing countdown. The countdown would be 60 or 120 seconds, which is to make sure that the sensors are fully activated. After countdown, the device enter normal detection interface.Take the detector out of the detected environment and wait for the data to get down to zero, then press the “ON/OFF” to turn off the detectorZero CalibrationZero calibration must be done in clean air. Better to do once after alarming happens.Press “MENU” to enter parameter setting mode, select the "calibrate zero", and press “ON/OFF” to enter the mode. Observe the value of “real time concentration”. If the reading is not zero and the drifting is too big when the reading is stable, then it is necessary to conduct zero point calibration.Press “ON/OFF”, the real-time concentration will go back to zero, and press ”ESC” to go back to detection mode, gas concentration values also back to zero.Note: Zero calibration of oxygen detector, nitrogen detector and carbon dioxide detector (target gases are component of the air) cannot be done in the air. Only the target point calibration (value of target point concentration is the standard concentration values in the clean air) can be done.Process of Over-range incorrect operationUsers should avoid using gases which exceed the measure range to impact the sensor, because it will affect the lifespan and sensitivity of the sensor, even, "poison" the sensor. If there is any over-range incorrect operation makes the detector displaying an concentration at a large reading, the remedy is to take the device out of the environment immediately and put it in clean air for over half an hour, and then observe the reading, if it keeps going down, then wait until the reading back to zero before powering it off, and do the zero point calibration next time before using it. If the reading maintained at full scale, user should send the device back to manufacturer or agent for repair or replacing the sensor.①— Air Inlet②— Air Outlet③— air chamber of sensor④— LCD⑤— PLUS⑥— MINUS⑦— MENU⑧— ESC⑨— ON/OFF----------------------------------------------------------------------------------------------------------------------------- Note*If detector is used for the gas cylinder detection, considering the high pressure in the cylinder, please use a pressure regulator, and keep it as the below data:Flow rate: 800mL~1L/minutePressure: 0.1MPa or 1Bar*Please put the detector in clean air for about 5 minutes and waiting for the data falling down to normal before turning it off after measurement.Operation InterfaceWhen the detector is turned on completely, the device will enter the detecting interface. The gas type will be showed on the top left, and the time and battery power will be at the right. In the middle, there is the real- time concentration. There will be BEEP-ON at the bottom left, which means the alarm is on. The PUMP-ON at the bottom right, which means the pump is working.Alarm StatusWhen the detected gas concentration is higher than the low alarm value, the alarm sound will be on, yellow light will be flickered.When the detected gas concentration is high than the high alarm value, the alarm sound will be on, red light will be flickered.Alarm SettingPress “Menu”, choose the “Alarm point set”, and start to set the alarm value.There are LOW POINT and HIGH POINT for set, press “MENU” to move the cursor to the value you want to set, and press the “PLUS” or “MINUS” to change the value. After the setting is done, press “ON/OFF” button to save the settings.Low Battery AlarmWhen the battery is low, there will be sound, light low battery alarm. There will be sound and light every 5 seconds to remind the user to charge the device in time. When the battery is used up, the device will be turned off automatically.Restore SettingWhen all the settings are wrong, or users operate the detector in a wrong way, you can restore the detector to factory settings. But if the detector works normally, please don’t operate this setting. In order to avoid wrong setting, password is needed. If you want to restore the detector to factory setting, please contact the supplier.Storage S et tingIn the storage setting, you can set the storage status and the interval. Every time you turn on the detector, the storage status defaults OFF, so you need to set the storage status if you want to record the data.Press MENU, choose the “Storage set”, move the cursor by pressing MENU at the “ENABLE”, press MINUS to change NO to YES.The storage interval can be 5 seconds, 10 seconds, 15 seconds, etc. The highest interval is 1 hour.(* The storage setting only for gas detector with data storage function)View H istory D ataPress the MENU, choose “view history data”. Then at the top is the record total number, and the reminder “PLEASE SELECT”. Now, if you press MINUS, then the record data will be from the first record to the second in turn. If the record number is above 10, and you want to check the specific number, you press the MENU again, then you can input the exact number and check that record(press the MENU to move the cursor, and press the MINUS and PLUS to change the number), press ON/OFF to confirm and then you will see the detailed record.In the detailed record interface, at the top are the record total number and current number. In the middle are the date and time, and the concentration is at the bottom.Erase H istory D ataTo make sure the detector work perfectly and you can check the history data quickly, we suggest you to erase the history data regularly. Press MENU, choose the “Erase ex_flash”, password is needed (the password is 9999), then press ON/OFF, it shows that “erasing”, and when finished, it will turn back to the detecting interface. Target Point CalibrationNote: Calibration needs to be done by professionals and with necessary accessories and standard gas.Prepare the standard gas before starting the target point calibration. In detection mode, press “MENU”, select “calibrate span”, press ON/OFF button to enter. Then you will need to enter password. (If you need password, please contact the manufacturer to get it)After entering the password successfully, press ON/OFF to enter the target point calibration interface, as shown in the picture. The interface will display “concentration”, “set value. The concentration is the result got from the calculation of several internal calibration parameters. The process of calibration is the process to recalculate the internal parameters of the device. The set value is the value need to be entered manually; it should be the concentration of the standard gas to be calibrated. Select the parameter under the current interface, modify its value with “PLUS” and “MINUS” button.The calibration process is as below:1.Connect the detector with standard gas cylinder by hose.2.Enter the target point calibration interface, set the “SET value”as the standard gas concentration.3.Release the standard gas to the detector in a flow rate of500mL/min. The value of “concentration” will become largergradually, and become stable after 30seconds.4.When the value of “concentration” is stable, press the “ON/OFF” button, the value of “concentration” will be same with oralmost same with the “Set value”. The calibration is finished.5.Cut off the standard gas supply. Press “ESC” to go back todetection interface.。
可燃气体检测报警器使用规范(SY6503—2000)

可燃气体检测报警器使用规范(SY6503—2000) 以下是SY6503―2000《可燃气体检测报警器使用规范》的一些主要规定:
1. 可燃气体检测报警器的安装位置应根据实际需要进行选择,需避免直接阳光照射、高温、易有震动或摇晃的地方。
2. 安装时要避免防潮、防尘和腐蚀物质的影响。
3. 可燃气体检测报警器的安装应平稳、牢固,确保其能正确工作。
4. 在使用可燃气体检测报警器前,应进行仔细检查,确保其完好,并对其进行适当的维护。
5. 可燃气体检测报警器的工作环境温度为-10℃到+50℃。
若超出该范围,应采取适当措施保证其正常工作。
6. 对于可燃气体检测报警器的保护区域,应进行适当的隔离和标识,确保无人触碰或损坏。
7. 可燃气体检测报警器应定期进行测试和校准,以保证其准确度和灵敏度。
8. 在可燃气体检测报警器发出报警信号时,应采取相应的应急措施,确保人员安全。
以上是《可燃气体检测报警器使用规范》的一些主要规定,具体使用时,请参考该标准的具体内容。
工业气体报警器——安全生产中必不可少的“保护伞”

工业气体报警器——安全生产中必不可少的“保护伞”
伴随经济的快速发展,我们在逐步进入工业化的同时,工业事故也在屡屡发生。
随之而来的,就是化学气体泄漏、煤矿爆炸、厂房起火、工人中毒等此类层出不穷的新闻报道。
这些事故发生的主要原因多是工业环境中的易燃易爆、有毒有害气体使用不当造成的。
为了预防人员中毒、保护公共财产,气体检测报警系统就成为生产中必不可少的保护伞。
可燃气体报警器简述
工业用的可燃气体报警器一般分为固定式和便携式两种:
固定式可燃气体报警系统由报警控制器和探测器组成,控制器可放置于值班室内,主要对各监测点进行控制,探测器安装于可燃气体最易泄露的地点,其核心部件为内置的可燃气体传感器,传感器检测空气中气体的浓度。
探测器将传感器检测到的气体浓度转换成电信号,通过线缆传输到控制器,气体浓度越高,电信号越强,当气体浓度达到或超过报警控制器设置的报警点时,报警器发出报警信号,并可启动电磁阀、排气扇等外联设备,自动排除隐患。
QB10N
QB10N型可燃气体检测报警仪,是一种固定式可连续检测作业环境中可燃气体浓度的仪器。
仪器采用进口传感器,测量精度高,稳定性好;嵌入式微控制技术,操作简单,功能齐全,可靠性高,整机性能可靠;支持故障自检,采用传感器自诊断技术,在传感器损坏,短路,断路,供电异常等情况下可自动报故障;支持红外遥控器,方便操作,性价比高,适合工商业燃气用户。
QB2000N
QB2000N气体检测仪为自然扩散方式检测气体浓度。
采用进口传感器,具有极好的灵敏度和出色的重复性。
仪器采用嵌入式微控制技术,功能齐全可靠性。
QB2000N智能氧气检测变送器

产品介绍:QB2000N智能模块化氧气探测器为自然扩散方式检测气体浓度,采用进口电化学传感器、催化燃烧式传感器、红外传感器或PID检测器,具有极好的灵敏度和出色的重复性;适宜工厂应用的LCD液晶或LED 数码显示器实时显示泄漏气体的浓度值,超过预设报警点立即启动声光报警信号或驱动排风系统;国际标准4-20mA信号可直接接入工厂DCS系统,RS485数字信号与工厂上位机连接;仪器采用嵌入式微控制技术,操作简单,功能齐全,可靠性高,整机性能居国内领先水平。
QB2000N 智能模块化氧气探测器具有性能卓越、运行稳定可靠、安装维护方便、测量气体种类齐全等特点,极大的满足了工业现场安全监测对设备高可靠性稳定运行和测量气体种类多样化的要求;已广泛应用于石油、化工、冶金、炼化、燃气输配、生化医药及水处理等行业。
功能特点:◆仪器采用先进的16位超低功耗嵌入式微控制器◆用户可自行设置高低报警点◆重要操作需密码验证,有效防止误操作◆标准三线制4-20mA电流信号输出,兼容现有报警控制单元或DCS(分散控制系统)◆RS485隔离数字信号与工厂上位机连接◆LED数码管显示或LCD液晶显示◆传感器故障自动识别并现场显示,同时输出相应故障电流信号◆-40~+70℃温度数字自动跟踪补偿,保证测量准确性◆标准三按键实现单人单点现场维护◆现场两级光报警,继电器输出(外接声光报警器或驱动排风等外设设备)◆探测器可以更换同类型传感器,也可以更换不同气体种类的传感器,不同量程传感器模块,探测器自动识别,无需标定技术参数:◆测量量程:见附表◆工作电压:24VDC±15%◆信号输出:4~20mA线性电流输出;或RS485信号输出◆响应时间:T90 小于30秒◆恢复时间:小于30秒◆分辨率:详见选型表◆精度:±3%F.S◆显示模式:LED数码管显示(可选液晶显示)◆环境温度:-30~+60℃(具体依据传感器参数)◆环境湿度:10-95% R.H.(无凝露)◆防爆等级:Exd IICT6(隔爆应用);ExiaIICT4(本安应用)◆防护等级:IP66◆安装螺纹:M20×1.5、G1/2◆使用电缆:3×1.5mm2或4×2.5mm2屏蔽电缆传输距离:≤1000m◆尺寸重量:160mm(L)140mm(W)85mm(H) 约1.5kg检测气体种类表。
ftd-2000说明书

FTD-2000 /FTD-3000 美国华瑞RAE无线气体检测仪产品介绍:产品型号:FTD-2000 (EC)/ FTD-3000(LEL)产品品牌:美国华瑞 RAE产品类别:气体检测仪产品备注:无线气体检测仪产品概述:美国华瑞RAE无线气体检测仪MeshGuard是一款集无线通信、气体检测、声光报警、大容量电池为一体的便携、固定两用气体检测设备, MeshGuard (FTD-2000) 是一款集成了无线通讯模块的单一有毒气体检测仪,主要作为固定式产品进行在线监测,也可做为便携式设备使用,可以和FMC-2000 无线控制器组成无线监控网络,提供点对点及点对多点的网络。
其特有的网络自组织、自愈合、自诊断、简便磁铁吸附安装等功能,使该设备可以方便的部署在任意需要监测的场所,有效降低安装成本,提高工作效率。
广泛应用于油气田勘探、消防部门应急救援监测、城市公用事业安全检测、危险化学物质检测、油气储运、精炼和石化、化工企业、地下管道、纸浆造纸、发电厂、冶金钢铁、其他工业安全等领域。
产品特点:·安装成本低,无需连线·带有自动网络漫游和配置功能的无线mesh 网络·通信距离超过300米视距范围·64位编码符合IEEE 802.15.4 标准的2.4GHz Mesh网络·多网络共存·多跳 mesh网络,覆盖面积大·可野外更换电池,可连续运行6个月·响亮报警,高亮度红色闪烁报警,大屏幕显示气体浓度·用户可设置高报、低报、S和TWA 报警值·标定简便·抗干扰能力强·耐酸碱腐蚀技术参数:*RFD:精简功能设备;**FFD :全功能模式设备操作范围大于300米,通视接收灵敏度 2.4GHz 频率下*小 -95dBm无线通信协议IEEE 802.15.4/Zigbee,带mesh stack实时读数实时检测值、峰值、TWA和S值,电池电压读值声音报警90dB @ 30cm光视报警高亮度红色LED(两级)RF认证FCC Part15 CE EN 300328SRRC (申请中)标准配置检测仪(包括天线)*检测仪单独包装不含磁铁安装套件。
YB-2000型离子感烟报警器使用说明书

YB-2000 型离子感烟报警器使用说明在夜间不容易被人们发觉YB-20002. 报警声大于70db3. 烟雾报警浓度为2%4. 输出信号 9V Max100mA5. 工作温度范围为0-50,相对湿度90%以下6. 壁挂或吸顶式安装直径115mm 厚45mm.使 用1.接入9V电源2.黄色按钮测试电路是否正常, 电路正常时, 按下测试按钮2秒钟后,发出”滴,滴”声且LED闪烁3.正常工作时每40秒LED闪亮一次, 给出电路正常工作信号4.电池不足, 电压降到8V时每40秒发出一声鸣响,电路仍可正常工作;若电压降到6V左右,则会连续发出”滴滴”声,应立刻更换电池5.本机带有电平(9V)输出口, 用于报警时输出控制信号.线路板上一组红/黑色线为+9V电源,另一组为9v电平输出端子.TEL:0755-******** 83376489 FAX:0755-******** 83338339Email:*****************欢迎索取免费详细资料、设计选型指南和光盘、样品;产品繁多未能尽录,欢迎来电查询。
中国传感器科技信息网:HTTP:///工控安防网:HTTP:///消费电子专用电路网:/E-MAIL:**************************MSN: suns8888@hotmail.com QQ: 195847376 地址:深圳市福田区福华路福庆街鸿图大厦1602室电话:0755-******** 83376489 83387030 83387016传真:0755-******** 83338339 邮编:518033 手机:(0)139****1329深圳展销部:深圳华强北路赛格电子市场2583号 TEL/FAX:0755-******** 25059422北京分公司:北京海淀区知春路132号中发电子大厦3097号TEL:010-******** 82615020 135******** FAX:************上海分公司:上海市北京东路668号上海賽格电子市场2B35号TEL:021-******** 56703037 137******** FAX:************西安分公司:西安高新开发区20所(中国电子科技集团导航技术研究所) 西安劳动南路88号电子商城二楼D23号TEL:029-8102261913072977981FAX*************成都:TEL:(0)137****6236 。
GST-BR T Y 002F独立式可燃气体探测器说明书

安装、使用产品前,请阅读安装使用说明书。
请妥善保管好本手册,以便日后能随时查阅。
GST-BR002F测量人工煤气的、GST-BT/Y002F测量范围为0~100%LEL的独立式可燃气体探测器安装使用说明书(Ver.1.14,2016.06)目录一、概述 (1)二、特点 (1)三、技术特性 (2)四、结构特征及工作原理 (4)五、安装与布线 (4)六、使用及操作 (8)七、故障分析与排除 (10)八、保养及维修 (10)九、注意事项 (10)十、特别声明 (12)一、概述GST-BR002F 测量人工煤气的独立式可燃气体探测器、GST-BT/Y002F 测量范围为0~100%LEL 的独立式可燃气体探测器(以下简称探测器)为非编码型壁挂式安装可燃气体探测器,用于检测可燃气体的泄漏,适用于家庭、宾馆、公寓等存在可燃气体的场所进行安全监控。
产品型号命名规则如下:二、特点 采用半导体气敏元件,工作稳定,使用寿命长,安装简单。
此类探测器为交流220V 供电。
GST-B联网方式为独立式联网方式为点型安装方式为吸顶安装安装方式为壁挂安装检测气体为天然气检测气体为液化石油气R 检测气体为人工煤气三、技术特性1. 工作电压:AC187V~AC253V。
2. 功耗:正常监视≤3.0W,报警状态≤5.0W。
3. 输出容量及控制方式:有源触点:适用于DC12V单向直流脉冲电磁阀;电磁阀驱动能力:1000μF电容放电。
无源触点:无源常开触点,容量220V/1A,可方便的控制联动设备。
4. 报警浓度:BT系列:甲烷(天然气)6%LELBY系列:丙烷(液化石油气)10%LELBR系列:氢气(人工煤气)400×10-6 5. 指示灯:电源指示灯:绿色;预热状态,闪亮;其他状态,常亮。
报警、故障指示灯:为双色指示灯,报警状态为红色,故障状态为黄色。
6. 蜂鸣器:报警时蜂鸣器每秒鸣叫约2次,报故障时蜂鸣器约每3s鸣叫一次。
新单点壁挂气体检测报警仪说明书

单点壁挂气体报警仪使用说明操作必读1、所有操作和测试本公司出产之仪器的操作人员,在操作前必须仔细阅读说明书。
本公司的仪器仅在按照制造厂商的要求操作时,才能正常工作。
2、本公司仪器的使用必须按照说明书确定的规则操作。
3、仪器的维修和部件的更换由本公司或各地维修站处理。
4、如果用户不依照以上说明擅自开机修理或更换部件,仪表的可靠性由操作者负责。
同时本公司不再负责保修。
5、本公司仪器的使用还应遵守国内有关部门及工厂内仪器管理方面的法令和规则。
6、仪器需要3至6个月标定一次,在保质期内本公司免费提供标定。
保修说明所有本公司生产的仪器享有24个月的保修期(电化学传感器除外,电化学传感器保修期12个月),保修期从出厂之日算起。
用户在使用中,应遵守使用说明,由于用户使用不当,或工作环境恶劣而造成仪器损坏,不在保修范围之内。
用户应妥善保管出厂合格证,保修期以合格证上的日期为准。
返修时请注意附上出厂合格证。
态。
在报警值输入状态,系统会自动显示上次设置的报警值。
此时最低位数值处于闪烁状态,表示可以修改最低位的值,通过按使闪烁位的数值在0~9 之间循环变化,而按来改变闪烁位置,这样通过和的组合来输入要设置的值。
参数值设置好之后必须按进行确认退出,否则将一直处于报警值输入状态。
2、恢复出厂设置值:在正常的显示状态下,按“”键和“”键,进入恢复出厂设置值状态。
此时系统进行倒计时,如果一直按住这2个键,则四位数码管的显示由 3333 到 2222再到 1111 最后显示 HFTC,此时表示出厂值恢复成功。
如果在显示 HFTC 之前的任何时间松开“”键或者“”键或者同时松开两个按键,则都会显示–OFF,此时表示出厂值恢复失败。
七、其它说明1、对于壁挂式的可燃气监控报警器,当可燃气的浓度达到 110%LEL 左右时,系统会自动关闭气体探测器的供电,使探测器停止工作,达到防爆的功能。
此时数码管会一直显示 100,继电器的常开开关端接通,两个发光二极管同时闪烁,蜂鸣器报警。
VDO-2000智能 燃气报警器 说明书

家用智能燃气泄露报警器使用说明书第一章技术参数1.1:特性1.)型号:壁挂式:VDO-20102.)供电电源:AC220V或DC12V3.)静态功耗:<1.3W4.)报警功耗:<1.7W5.)使用环境:温度:-10℃~45℃温度:30~-90%6.)报警浓度:天然气:10~25%LEL液化石油气:10~25%LEL城市煤气:2~5%LEL7.)报警输出:声光报警,常开或常闭信号,控制排气扇、电磁阀、机械手信号(可选)1.2:使用范围对天然气、城市煤气、液化石油气等可燃气体的超浓度做可靠报警,可广泛用于家庭、煤气站、煤矿等各种场合。
第二章安装指南2.1 :核实部品清单一套完整的报警器包括:一台报警主机一本使用说明书一条外接端子线(联网或联排机型)2.2:根据燃气的比重安装燃气泄露报警器天然气、城市煤气:因其比空气轻,会悬浮于天花板,故报警器应安装在低于天花板0.3-1.2米,距气源半径1.5米以内的合适之处。
安装注意:燃气泄露报警器1.)不要正对炉灶的油烟、蒸气;2.)不要安装在通风良好处;3.)不要被窗帘或橱柜屏蔽隔断;4.)不要安装在浴室等水蒸汽较大处。
2.3:外接端子线使用说明1.)采用系统12V供电时,外接端子红线接正极和黑线接负极2.)联网开头信号输出:白线:公共端。
绿线:常闭触点。
黄线:常开触点。
3.)联接排气扇将白线和黄线串联于排气扇开关的火线上;4.)无线型:根据报警主机的要求,工作频率315M或433M可选,并在发射模块上编好数据码和地址码。
第三章使用指南3.1:预热状态Ⅰ.吸顶式:接通AC220V或DC12V民源,此时绿色指示灯闪烁表明报警器处于预热状态Ⅱ.壁挂式:接通AC220V或DC12V电源,此时红色指示灯常亮,表明报警器处于好面热状态3.2:监控状态Ⅰ.吸顶式:约3分钟后,绿色指示灯亮,表明报警器处于监控状态。
Ⅱ.壁挂式:约3分钟后,红色指示灯来,绿色指示灯常亮,表明报警器处于监控状态。
ES2000气体报警装置(V2.2)

ES2000气体报警装置使用说明书(V2.2)质量方针通过我们对工作质量的持续改进来满足顾客的需求,并使顾客得到发展及成功。
设备安装、操作和维护之前务必仔细阅读技术手册。
特别留意警告和注意事项。
所有警告都此处列出,并在手册相应章节中重复提到。
注意事项分别在相应章节中列出。
安装过程及操作必须严格遵照国家相关标准要求。
探测器内部的任何操作都必须由专业人员执行。
打开探测器机壳之前,为减少危险气体点燃的风险,必须先断开电源。
切勿在危险气体可能存在的情况下打开接线盒/机壳,或更换传感器。
探测器必须安全接地,以防受到射频干扰的影响。
设备内外各有一个接地点。
确保所有屏蔽层都在控制器星形接地点处或探测器接地点处,可靠接地。
但两者不得同时接地,否则会形成接地回路,从而导致误报。
传感器内部可能含有腐蚀性溶液,故处理时应特别小心。
切勿擅自或任意拆卸传感器。
不得将传感器置于超建议范围的温度下。
不得将传感器置于有机溶剂或可燃性液体中。
传感器使用期限达到时,应从环保的角度,依照地方废物管理以及环境法规的要求进行安全处理。
信息提示以下警告提示在整个手册中都会提到。
警告:清楚任何可能导致重大事故和人身伤亡的危险或不安全隐患。
注意:清楚任何可能导致人身伤害或产品或财产损失的危险或不安全隐患。
备注:清楚有用/附加信息。
针对任何此资料中未提到的信息,或有必要添加或纠正的内容,请直接联系深圳市特安电子有限公司。
深圳市特安电子有限公司真诚接受任何针对资料内容上的错误或遗漏而提出的批评指正。
目录1. 产品概述 (2)2. 产品技术指标、结构 (3)2.1 主要技术指标 (3)2.2 结构 (4)2.2.1 探测器结构 (4)2.2.2 控制器结构 (4)3. 产品安装 (6)3.1 探测器的安装 (6)3.2 控制器安装 (7)3.3 电缆线连接 (9)4. 产品使用 (12)4.1 上电预热三分钟(系统初始化阶段) (12)4.2 监控状态 (13)4.3 功能操作 (14)5. 产品维护 (19)5.1 探测器的寿命及注意事项 (19)5.2 常见故障及处理方法 (19)1. 产品概述ES2000气体报警装置是由探测器与报警控制器组成的工业用可燃气体及有毒气体安全检测仪器。
常见十大有毒气体分析及预防对策

常见十大有毒气体分析及预防对策有毒气体是看不见摸不着,却能杀人于无形之中,甚至短期时间内就可能令人死亡,不管是国内还是国外目前都会受到有毒气体的威胁,到底你工作和生活的场所有没有大量的有毒气体存在,本文将为您分析最常见的十大有毒气体,它们分布广泛,对人危害大,务必要重视对有毒气体的预防工作。
一、氢氰酸(剧毒类)来源环境中的氰化物主要来自工业“三废”,也有含氰的杀虫剂或药剂污染的;汽车尾气和香烟的烟雾中都含有氰化氢,某些塑料制品的燃烧也会产生氰化氢,氰化钠、氰化钾用于金属电镀、矿石浮选、染料,制药、金属着色、铂金精炼等工业。
危害急性氰化氢中毒的临床表现为患者呼出气中有明显的苦杏仁味,轻度中毒主要表现为胸闷、心悸、心率加快、头痛、恶心、呕吐、视物模糊。
重度中毒主要表现呈深昏迷状态,呼吸浅快,阵发性抽搐,甚至强直性痉挛。
预防一定要严格遵守操作规程,普及防毒和急救知识,加强个人防护,发生氰化氢中毒事故应到现场及时抢救,佩戴防毒面具。
含氰废气、废水应经处理后方能排放,国内常用氯碱法净化。
针对氢氰酸这类有毒气,可采用驰诚电气这款QB2000N模块气体检测变送器来检测气体,这款工业气体检测变送器为自然扩散方式检测气体浓度,采用进口传感器,具有极好的灵敏度和出色的重复性;适宜工厂应用的LCD液晶或LED数码显示器实时显示泄漏气体的浓度值,超过预设报警点立即启动声光报警信号或驱动排风系统;国际标准4-20mA信号可直接接入工厂DCS系统,RS485数字信号与工厂上位机连接;仪器采用嵌入式微控制技术,操作简单,功能齐全,可靠性高,整机性能可靠。
二、氯气(剧毒类)氯气来源氯气分布行业广泛:可见于工艺美术品制造业;无机盐制造业;医药工业:合成药卤化、氧化、加成、扩开环、硫化;轻有色金属冶炼业:铝合金熔铸、镁电解、镁氯化、四氯化钛冶炼;稀有色金属冶炼业:铋制取、氧化锗制取;其他基本化学原料制造业:金属钙制取、镍化合物制取、碘制取、溴制取氯化硫制取、亚硫酰氯制取、硫酰氯制取、漂粉精制备、液氯冷冻、液氯灌装;有机化工原料制造业:氯丁二烯合成、甲烷氯化、甲醇加氢氯化、一氧化碳氯化、等其他有机原料合成。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
QB2000F单点壁挂式可燃气体检测报警器
QB2000F单点壁挂式可燃气体检测报警器产品介绍:
QB2000F单点壁挂式可燃气体检测报警器,单点壁挂式氧气检测报警器,可燃性气体浓度氧气浓度连续检测仪,有毒有害气体浓度监测。
QB2000F单点壁挂式可燃气体检测报警器可更换不同芯片,检测不同气体,现场声光报警,控制接点输出,仪器采用嵌入式微控制技术,全中文菜单操作简单,功能齐全,可靠性高,整机性能居国内领先水平。
QB2000F单点壁挂式可燃气体检测报警器功能特点:
仪器采用先进的32位嵌入式微控制器
128*64点阵图形液晶显示
用户可自行设置高低报警点
全中文菜单方便国内用户使用
首次报警时间显示功能
具有实时时钟功能
自动校准功能,减少测量误差
报警记录自动存储200条
备用电池非报警状态下可工作2小时以上(用户选配)
标准4-20mA信号可直接接入工厂DCS系统(用户选配)
RS485数字信号可与工厂上位机连接(用户选配)
传感器模块更换后可自动识别,无需重新标定,传感器模块可与我公司模块化探测器通用QB2000F单点壁挂式可燃气体检测报警器技术参数:
测量范围:0-100%LEL
显示误差:≤±3%F.S
响应时间:T90<30s
显示方式:128*64点阵式液晶屏实时显示数据及系统状态
报警提示:广角高度发光提示、100dB蜂鸣音随浓度增加频率加大
报警点:一级报警用户设定二级报警用户设定
报警输出:两路继电器输出,容量AC 220V 2A
信号输出:国际标准4-20mA信号可直接接入工厂DCS系统(用户选配)
RS485数字信号与工厂上位机连接(用户选配)
工作环境:-30°~+50°;湿度<95%RH无结露
工作电压:AC 220V 50HZ
备用电池供电可连续工作2小时以上(用户选配)
防护等级:IP65
重量:约1200g
QB2000F检测报警器检测气体参数:
产品名称被测气体测量范围分辨率响应时间
一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒
氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒
臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒
硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒
氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒
氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒
氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒
二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒
一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒
二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒
环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30
二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒
甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒
氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒
可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒
氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒
丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒
氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒
光气检测仪/报警器0-1PPM 0.01PPM ≤30秒
苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒
苯检测仪/报警器0-100PPM 1PPM ≤30秒
甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。