FCFC参数设置中文说明(终审稿)
光参数fc
光参数fc光参数(fc)是指光纤通信系统中的一个重要指标,也称为光纤的截止频率。
光纤通信是一种基于光的传输技术,通过利用光纤中的光信号来传输数据。
光参数fc是光纤通信系统中用来描述光信号传输特性的一个重要参数。
光参数fc是指在光纤中传播的光信号频率的临界频率。
在光纤中,光信号的传播速度会受到光纤的材料特性以及光信号的频率的影响。
当光信号频率低于光参数fc时,光信号会在光纤中传播得非常好;但当光信号频率高于光参数fc时,光信号的传播会受到限制,导致光信号的衰减和失真。
光参数fc的数值取决于光纤的材料特性和结构参数。
通常来说,光纤的材料特性会决定光参数fc的数值。
光纤材料的折射率是影响光参数fc的一个重要因素。
折射率是指光在介质中传播时的速度与真空中光速的比值,不同折射率的光纤具有不同的光参数fc。
光参数fc的大小对光纤通信系统的传输性能有着重要的影响。
当光参数fc的数值较高时,光纤可以传输更高频率的光信号,从而可以实现更高的数据传输速率。
因此,提高光参数fc的数值可以提高光纤通信系统的传输容量和速率。
为了提高光参数fc的数值,可以采用一些措施。
例如,可以选择具有较高折射率的光纤材料,或者采用多层包覆结构来增加光纤的折射率。
此外,还可以通过优化光纤的结构参数,如光纤的直径和包覆层的厚度,来提高光参数fc的数值。
除了光参数fc之外,光纤通信系统中还有其他一些重要的光参数。
例如,光纤的损耗是指光信号在光纤中传播过程中的衰减情况,通常以单位长度的损耗来表示。
光纤的带宽是指光纤可以支持的最大数据传输速率,通常以单位频率带宽来表示。
这些光参数和光参数fc一起,共同决定了光纤通信系统的传输性能。
光参数fc是光纤通信系统中的一个重要指标,用来描述光信号在光纤中传输的特性。
光参数fc的数值取决于光纤的材料特性和结构参数,对光纤通信系统的传输性能有着重要的影响。
提高光参数fc的数值可以提高光纤通信系统的传输容量和速率,可以通过选择合适的光纤材料和优化光纤的结构参数来实现。
FC系列中文操作说明(神港)
注意
• PID自整定(AT)的执行,请在试运行时实施。 • 为防止触电及发生调节仪故障,通电中请勿触及端子。 • 在实施端子锁紧或清洁作业时,必须在调节仪电源关闭的情况下执行。
通电期间作业,可能因触电而产生重大人身伤害。 • 在清洁时,请用柔软的干布。 • 应避免用硬物撞击和刮擦显示器。
1.2 模糊自整定 (1) 控制开始时,由以前的 PID 参数执行控制。 (2) 当控制结果因扰动或过程变化而异常时,仪表则监测此时的收敛状态,如有必要,自动调整 PID 参数。 (a)如收敛平滑且速度不慢,不改变 PID 值。 (b)如收敛速度太慢,仪表校正 PID 值使收敛变快。 (c)收敛过程中发现超调时,仪表自动调节 PID 值以避免发生超调。 (d)发生振荡时,调节仪检查波形和精细地自动调节 PID 值。 (3) 由内部开关设置,可使调节仪设定为带或不带模糊自行整定的 PID。
功能
1
控制方式
和
2
模糊自整定PID 控制 PID 控制 PD 控制 ON/OFF 控制
加热/冷却 3
加热(反作用)动作 冷却(正作用)动作
报警 1
无待机动作
待机
4
待机动作
报警 2
无待机动作
待机
5
待机动作
/
6
输入传感器
7*
K, J, R, B, N, PL- , Pt100, JPt100 S, E, T, C, 4 ~ 20mA, 0 ~ 20mA,
• 本调节仪使用说明书内所记载的注意及警告事项,请严格遵守。 如不遵守,可能导致重大伤害事故,请注意。
• 本说明书记载的内容可能会有变更。 • 本说明书尽可能予以周全叙述,如有不详或错误,敬请谅解,并予告知。 • 本调节仪计划安装在控制屏内,如果不是,请保证工作人员不能触摸到电源端子和高压部分。 • 不可将调节仪用于涉及人身安全的医学应用。 • 禁止任何未经授权的部分或全部复制本说明书。 • 本调节仪外壳是由阻燃树脂等做成的,请勿在易燃材料附近或易燃材料上安装本调节仪。
FC系列中文说明书
重量(g)
75 122 253 75 122 253 75
索尼及索尼兼容型 相机和闪光灯 奥林巴斯、松下及 奥林巴斯松下兼容型 相机和闪光灯
122 253 75 122 253
(本表数据更新至2011年05月01日,之后发布的产品以实际参数为准。)
现在,你可以体验无与伦比的PIXEL产品。如有任何疑问可以 向当地经销商咨询,或登陆 查询
安装连接
安装相机连接端 拆卸相机连接端
3
1
2
3、将热靴固定螺母按图示向左旋转锁紧。
先关闭相机电源,按图示步骤松开热靴固定 螺母,再从相机机顶热靴座拔出连接端。 如果连接端无法从机顶热靴座拔出
请检查热靴固定螺母是否完全松开,并轻 轻摇动连接端,再从机顶热靴座上拔出。却勿 用力将连接端从机顶强行拔出,以免损坏设备。
必须将相机连接端安装到位,锁 紧热靴固定螺母,以防止产品从相机 上滑落。
安装连接
固定闪光灯连接端 固定闪光灯连接端
1
2
1、按图示步骤将快装板螺丝锁入离机线中闪 光灯连接端的快装板固定螺母。 2、将快装板安装于固定支架上。
安装连接
固定闪光灯连接端 安装闪光灯
1
1
或者将闪光灯连接端直接插入闪光灯支 或者将闪光灯连接端直接插入闪光灯支架 进行固定。 架进行固定。
闪光灯离机连接线
FC-311 FC-312 FC-313 FC-314
感谢您购买高性能的PIXEL产品
使用手册
总述 首 先 非 常 感 谢 您 购 买 高 性 能 的PIXEL产 品。闪光灯离机连接线可使闪光灯从相机机 顶分离出来,使闪光灯能打出各种灵活角度的 灯光却不改变闪光灯原有的各种功能。 在使用前,您一定要读通并完全理解本 使用说明书以及了解相机和闪光灯的使用方 法,以保证您能熟悉操作和正确使用。
FC简易操作说明
FX-501-C2简易操作说明本操作说明仅代表FX-501-C2在切槽装配机上的使用,详细设置或应用到到其它场所请查看FX-501-C2的官方说明书。
1.复位设置1.1、在待机画面按“MODE”键三下,显示“”。
1.2、按“SET”键一下,显示“”。
1.3、按“+”键四下,显示“”。
1.4、按“SET”键一下,显示“”。
1.5、按“+”键二下,显示“”。
1.6、按“SET”键一下,显示“”。
1.7、按“SET”键一下,显示“”并闪烁,这时感应器复位中,完成后会自动返回待机画面。
2.输出设置(常开/常闭设置)2.1、在待机画面按“MODE”键三下,显示当前输出设置状态。
“”代表设定值(绿色)比检测值(红色)低时有输出。
“”代表设定值(绿色)比检测值(红色)高时有输出。
2.2、按“+”键或“-”键选择所需要的输出设置。
2.3、按“MODE”键四下,返回到待机画面。
3.设定值调整3.1、在没有放入检测物的状态下,观察并记录当前检测值(红色)。
3.2、在放入检测物的状态下,观察并记录当前检测值(红色)。
3.3、计算初步设定值:①有料检测值>无料检测值时初步设定值=(有料检测值-无料检测值)/2+无料检测值②有料检测值<无料检测值时初步设定值=(无料检测值-有料检测值)/2+有料检测值3.4、通过按“+”键和“-”键输入初步设定值,完成后感应器会闪烁几下并自动存储。
3.5、试运行并观察检测效果,需要时通过按“+”键和“-”键微调设定值,以达到最佳效果。
4.震盘料反吹气逻辑5.直震2胶盖反检测逻辑。
FC参数设置方法
FC参数设置方法FC(Fully Connected)层是神经网络中常见的一种层类型,通常用于将前一层的输出与当前层的输出进行全连接。
在深度学习中,FC层广泛应用于分类、回归等任务中。
在使用FC层时,合理设置参数是非常重要的,下面将介绍一些常用的FC参数设置方法。
1.设置神经元数量:在使用FC层时,首先要确定每个FC层的神经元数量。
神经元数量决定了FC层的表达能力,一般来说,神经元数量越多,FC层的表示能力越强。
但是太多的神经元数量会引起过拟合问题,而太少的神经元数量则可能导致欠拟合。
通常的做法是通过实验或者经验选择适当的神经元数量。
2.设置激活函数:在FC层中,激活函数对神经元的输出进行非线性变换,增加了网络的表达能力。
常见的激活函数有sigmoid、tanh、ReLU等。
选择适当的激活函数有助于提高网络的性能。
一般来说,ReLU是一种比较常用的激活函数,在实践中表现较好。
3.设置输入大小:在使用FC层之前,需要确定输入数据的大小。
输入数据的大小决定了FC层中权重参数的维度,也决定了输出数据的大小。
合理设置输入数据的大小有助于减少计算量和内存占用。
4.设置权重初始化方法:权重的初始化方法对网络的训练和性能具有重要影响。
常见的权重初始化方法有随机初始化、Xavier初始化、He初始化等。
随机初始化是最常用的方法,即将权重参数随机初始化为一个很小的值或者很大的值。
Xavier初始化和He初始化是针对ReLU激活函数提出的初始化方法,能够更好地保持梯度流动性。
根据网络结构和激活函数的不同,选择适当的权重初始化方法。
5.设置偏置初始化方法:除了设置权重初始化方法,还需要设置偏置初始化方法。
偏置初始化方法通常与权重初始化方法配套使用。
常见的偏置初始化方法有常数初始化、零初始化等。
根据实际需求和初始化方法的特点,选择适当的偏置初始化方法。
6.设置学习率:学习率是深度学习中非常重要的一个超参数,用于调整权重参数的更新幅度。
FC存储网络配置手册
光纤通道是一个标准化的网络通信协议,在网络通信的七层协议模型中属于第二层,是一种数据链路层的协议,与以太网同类。
光纤通道的传输层是协议无关的,原则上它可以传输各种第三层协议。
但光纤通道并没有像以太网那样用于支持IP协议,或支持其他的上层协议,而主要用来支持SCSI数据存储协议。
这是因为光纤通道具有通道的特征,适用于在发起方和目标方两个结点之间的通道上传输数据帧;另一方面,光纤通道将更多的功能硬件化并采用光纤传输,具有可靠的性能保证.主机和存储阵列设备经FC存储网络连接的一个典型拓扑如图1所示。
图1 主机/存储阵列连接在FC存储网络中,主机和存储设备总是采用冗余的链路连接,以消除任何单点故障隐患。
图示中有两台FC交换机;每台主机有两个HBA接口,分别连接到两个FC交换机;每个磁盘阵列有两个控制器,每个控制分别连接到两个FC交换机。
磁盘阵列的两个控制器具有对等的地位,任何一个控制器都可以支撑整个设备的运行,两个控制器工作在双活的运行模式,既负载均衡又故障冗余.一般情况下,磁盘存储阵列都配有两个控制器,一些高端设备还可以配置多个控制器.在图1所示的交换式网络中,每个主机到每个磁盘阵列设备的物理路径有4条.图2显示了一个磁盘存储阵列控制上的FC接口.示例中的磁盘阵列有2个控制器,标识分别为A和B,每个控制器上由4个4GBps速率的FC接口.图2 存储阵列控制器上的FC接口在FC存储网络中,不论是发起方主机还是目标方存储设备都被称为节点,节点设备上的每个FC物理接口被称为N端口(Node Port)。
节点设备通过FC交换机互连被称为交换式SAN,连接设备N端口的交换机物理接口被称为F端口(Fabric Port).节点设备在网络中寻址使用设备的世界范围名(WWN:World Wide Name),WWN是设备制造商向IEEE注册得到的,可以保证每个设备WWN是全球惟一的。
WWN细分为一个64位的世界范围结点名(WWNN: World Wide Node Name)和一个64位的世界范围端口名(WWPN:World Wide Port Name)。
SCALE-FC105说明2013
FC105、FC106参数设置中文说明20131、FC105SCALE功能接受一个整型值(IN),并将其转换为以工程单位表示的介于下限和上限(LO_LIM和HI_LIM)之间的实型值。
将结果写入OUT。
SCALE功能使用以下等式:OUT = [ ((FLOAT (IN) -K1)/(K2-1)) * (HI_LIM-O_LIM)] + LO_LIM常数K1和K2根据输入值是BIPOLAR还是UNIPOLAR设置。
BIPOLAR:假定输入整型值介于 7648与27648之间,因此K1 = -7648.0,K2 = +27648.0 UNIPOLAR:假定输入整型值介于0和27648之间,因此K1 = 0.0,K2 = +27648.0如果输入整型值大于K2,输出(OUT)将钳位于HI_LIM,并返回一个错误。
如果输入整型值小于K1,输出将钳位于LO_LIM,并返回一个错误。
通过设置LO_LIM > HI_LIM可获得反向标定。
使用反向转换时,输出值将随输入值的增加而减小。
FC105参数参数说明数据类型存储区描述EN 输入 BOOL I、Q、M、D、L 使能输入端,信号状态为1时激活该功能。
ENO 输出 BOOL I、Q、M、D、L 如果该功能的执行无错误,该使能输出端信号状态为1。
IN 输入 INT I、Q、M、D、L、P、常数欲转换为以工程单位表示的实型值的输入值。
HI_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示的上限值。
LO_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示的下限值。
BIPOLAR 输入 BOOL I、Q、M、D、L 信号状态为1表示输入值为双极性。
信号状态0表示输入值为单极性。
OUT 输出 REAL I、Q、M、D、L、P 转换的结果。
RET_VAL 输出 WORD I、Q、M、D、L、P 如果该指令的执行没有错误,将返回值W#16#0000。
FC300 接线及参数设置
FC300变频器控制接线及参数设置1. 应用要求:变频器一拖一控制,正反转,高低速控制。
2. 变频器控制线路接线图:394201频率输出运行0219275553123332F C 300高速给定正转04报警05185554低速给定反转高速低速说明:在启动反转时,要等到变频器停止输出后再启动反转。
32号端子闭合后选择菜单3,高速。
33号端子闭合后选择菜单2,低速。
3. 主要设置参数(高速)1-22 电动机电压按电机铭牌1-23 电动机频率按电机铭牌1-24 电动机电流按电机铭牌1-25 电动机转速按电机铭牌3-41 加速时间30 加速时间3-42 减速时间30 减速时间3-16 参考值来源2 2 模拟输入端544-12 电动机速度下限0 频率4-14 电动机速度上限50 频率5-11 端子19输入11 启动反转5-14 端子32 24 菜单选择位15-15 端子33 23 菜单选择位05-12 端子27 2 惯性停车5-40 继电器1 9 报警5-40 继电器2 5 运行3)最后把参数0-10的参数设置为9,多重菜单。
4. 要在菜单3,和菜单2里把参数都设置一遍,最后把0-10的参数设置为多重菜单,运行前可闭合32,33号端子,观察一下菜单有无变化,可在面板上看到菜单的变化。
5. 运行时先按一下变频器控制面板的AUTO ON 键,然后才能启动变频器运行。
注:4-10设置为双向,5-11也应改为双向。
另外,由于端子32、33的转换为非无扰切换,所有在菜单的切换过程中会跳转到其他的菜单,比如菜单1,此时就应该在菜单1中也设置5-14和5-15这两个参数。
丹佛斯变频器FC使用说明
使用说明一、FC360的功能二、FC360本机面板使用HandON从出厂设定开始(未接控制线),首先,按【OffReset】键使变频器处于停止状态,设定参数5-12改为【0】,退出到Status状态,这时,还是【OffReset】键上的灯亮,按【OK】键,面板中心显示4位数值,设定手动频率,上下键增减,右键可窜位,设定好后,按【Handon】键计开始运行,运行过程中直接按键改变数值则立即更改输出。
按【OffReset】键停止。
设定的频率值将保持,再次按【Handon】键,将从运行最后的设定值。
三、FC360参数设定方法:通用的参数设定方法:首先,按【OffReset】键使变频器处于停止状态,按【MENU】键显示OM1状态此时在按一次【MENU】键则进入菜单1模式,按上键或下键可以修改参数组号,按【OK】进入此参数组,按上下键找到你需要改的参数号,按【OK】键该设定参数值闪烁,按上下键修改参数值(功能代码),若按【ok】键保存此次修改的参数。
若按【back】键则取消修改。
四、参数初始化修改参数14-22设定为2(初始化),然后从新上电,此时报警为A80,按【OffReset】键复位后红色报警等已灭,但显示窗口仍有A80报警显示,变频器需再次从新上电。
五、参数复制到LCP面板。
修改参数0-50参数,当0-50,设为【1】所有参数到LCP,从变频器拷贝参数到面板,等待完成。
设为[2]则把面板中参数拷贝到变频器,从LCP传所有参数。
完成后参数自动改为【0】。
六、使用同步电机的设定步骤按下表设定:1、首先,设定1-00,1-01,1-10,及1-24,1-25,1-26(按电机铭牌)2、电机自学习AMA,设定1-29,为【1】,按OK键,按【Handon】键,等待,经过一段时间,会显示“按【OK】键完成AMA”,按下【OK】键完成。
3、输入电机反电动势1-40;输入电缆长度1-424、输入其它参数;5、试运行。
光模块接口区分(终审稿)
光模块接口区分文稿归稿存档编号:[KKUY-KKIO69-OTM243-OLUI129-G00I-FDQS58-三、接口的主要类型:光纤接口是用来连接光纤线缆的物理接口,通常有SC、LC、FC、ST等几种类型。
不同的光模块对应的光纤接口不尽相同。
1×9及GBIC光模块通常采用SC光纤接口,而SFP和XFP封装形式的光模块通常采用LC光纤接口。
LC、SC、FC等均指外形尺寸,PC、APC、UPC都是指光纤连接器的插针端面。
装置在光纤末端使两根光纤实现光信号传输的连接器,光信号通过时只引入很低衰减的装置。
光纤连接器,是光纤与光纤之间进行可拆卸(活动)连接的器件,它把光纤的两个端面精密对接起来,以使发射光纤输出的光能量能最大限度地耦合到接收光纤中去,并使由于其介入光链路而对系统造成的影响减到最小,这是光纤连接器的基本要求。
在一定程度上,光纤连接器影响了光传输系统的可靠性和各项性能。
分类光纤连接器按传输媒介的不同可分为常见的硅基光纤的单模、多模连接器,还有其它如以塑胶等为传输媒介的光纤连接器;按连接头结构形式可分为:FC、SC、ST、LC、D4、DIN、MU、MT等等各种形式。
其中,ST连接器通常用于布线设备端,如光纤配线架、光纤模块等;而SC和MT连接器通常用于网络设备端。
按光纤端面形状分有FC、PC(包括SPC或UPC)和APC;按光纤芯数划分还有单芯和多芯(如MT-RJ)之分。
光纤连接器应用广泛,品种繁多。
在实际应用过程中,我们一般按照光纤连接器结构的不同来加以区分。
以下是一些目前比较常见的光纤连接器:FC型光纤连接器这种连接器最早是由日本NTT研制。
FC是Ferrule Connector的缩写,表明其外部加强方式是采用金属套,紧固方式为螺丝扣。
最早,FC类型的连接器,采用的陶瓷插针的对接端面是平面接触方式(FC)。
此类连接器结构简单,操作方便,制作容易,但光纤端面对微尘较为敏感,且容易产生菲涅尔反射,提高回波损耗性能较为困难。
FC302参数设置
DANFOSS FC302 变频器参数设置说明参数号 参数说明 参数值1-00 控制方式 0 开环 1 闭环3-00 参考值范围 0 最小~最大,1 –最小~ +最大3-01 参考值单位 默认转速3-02 最小参考值 默认值,单位跟3-01 相同3-03 最大参考值 根据输出频率上限需要设置3-15 参考值来源1 11 本地控制总线3-41 加速时间1 0.01—3600 s3-42 减速时间1 0.01—3600 s4-10 电机方向 0 顺时针,1 逆时针,2 双向 5-10 18 号端子功能 0 无功能5-11 19 号端子功能 0 无功能5-12 27 号端子功能 0 无功能5-13 29 号端子功能 0 无功能8-01 控制地点 0 数字和总线8-04 控制字超时功能 2 停止8-50 惯性停车选择 3 逻辑或8-51 快速停止选择 3 逻辑或8-52 直流制动选择 3 逻辑或8-53 启动选择 3 逻辑或8-54 反向选择 3 逻辑或8-55 菜单选择 3 逻辑或8-56 预置参考值选择 3 逻辑或9-16 PCD过程数据读取配置 16组参数里面根据需要任意选择 9-18 站点地址 0-126(软件设置)9-22 通信配置 PPO1-PPO810-00 CAN Profile 1 DEVICENET10-01 波特率选择 0 125kbps,1 250kbps,2 500kbps 10-02 站址选择 0~63 硬件拨码优先,波特率也一样10-10 过程数据类型选择 0 100/150, 1 101/151 , 2 20/70 10-12 过程数据配置读取(10-10 参数选择1) 16组参数里面根据需要任意选择9组参数为Profibus网络参数选择10组参数为DEVICENET网络参数选择对于10-12号参数,只有10-10 配置成101/151 通信协议时可用,电机正向启动控制字为1148,反向启动控制字为33916,停止控制字为1084,频率字最大为16384,电机状态反馈字里面第7 位为故障位(1 为故障),第8位为达速位(变频器达到设定频率),第11 位为运行位。
FC操作手册
目录第一章 系统简介·············································································································································1. 特点 ······················································································································································· 2. 性能参数·················································································································································· 3. 外形尺寸·················································································································································· 4. 兼容设备目录············································································································································ 5. 系统结构··················································································································································第二章 安 装················································································································································1. 安装过程·················································································································································· 2. 接线图····················································································································································· 3. 拨码开关设置··········································································································································7第三章 操 作················································································································································1. 界面显示·················································································································································· 2. 液晶窗口显示············································································································································ 3. 用户级别·················································································································································· 3.1 登录 ················································································································································· 3.2 退出 ················································································································································· 4. 状态类型··············································································································································20 5. 火警事件处理············································································································································ 6. 故障事件处理············································································································································ 7. 监管事件处理············································································································································ 8. 启动/反馈事件处理 ····································································································································· 9. 实时事件查询············································································································································ 10. 设备属性查询············································································································································ 11. 历史记录查询············································································································································ 12. 如何进行屏蔽/开放 ····································································································································· 13. 如何进行启动/停止 ····································································································································· 14. 如何进行测试/移动测试 ······························································································································· 15. 如何进行定位测试/定位恢复 ························································································································· 16. 如何设置蜂鸣器音量··································································································································· 17. 如何设置登录时间······································································································································ 18. 如何设置移动测试时间································································································································ 19. 如何设置 LCD 关闭时间 ······························································································································ 20. 如何设置时间··········································································································································0 21. 如何进行系统检测······································································································································ 22. 如何保存配置············································································································································ 23. 如何修改参数············································································································································ 24. 如何新建/查看联动关系 ······························································································································· 25. 如何编辑/删除联动关系 ······························································································································· 26. 如何进行组分配/FRT 分配 ··························································································································· 27. 如何查看帮助信息······································································································································ 28. 如何操作联动盘········································································································································· 29. 如何打开/关闭打印机 ·································································································································· 30. 如何替换设备············································································································································。
丹佛斯FC参数设置
按一下菜单键可切换显示、基本设置、区域设置中的一个界面按2次返回键可退出目录FC111设置向导1-2*电动机数据(按电机铭牌设置)1-20电动机功率--- KW1-22电压---- 380V1-23频率---- 50HZ1-24电流--- A速度上限---- 50HZ6-19端子53的模式---电流模式6-12端子53低电流---- 11.2 (最小频率)6-13端子53高电流---- 14.2(最大频率)手动操作按手动键可切换手动操作,按上、下键可修改频率,按停止/复位键可停止运行。
1-**负载和电动机1-06 顺时针方向----正常(改--反向,电机反转)3-**参考值/加减速3-1*参考值给定频率(自动运行)3-10预置参考值--- [0]100% (100% 对应50HZ)3-15预置参考值来源--- [0]无功能模拟量控制3-10预置参考值--- [0]0%3-15预置参考值来源--- [1]模拟输入535-**数字输入/输出5-1*数字输入5-10端子18数字输入------[0]启动5-11端子19数字输入------[11]反向启动5-12端子27数字输入------[1]复位5-4*继电器输出5-40继电器功能---[0][9]报警(端子1,2,3)---[1][5]变频器在运行(端子4,5,6)端子说明:12----公共端,18---正转,19----反转,27---复位;53、55----模拟电流输入(53V-,55V+)1,2,3---故障输出, 4,5,6----运行输出8-**通讯和选择FC端口设置协议----FC (Modbus RTU) 地址----1 波特率--9600 Baud 偶效验,1停止位变频器初始化为默认设置14-**特殊功能14-2*跳闸复位1.选择14-22工作模式2.按?[OK](确定)。
3.选择初始化,然后按?[OK](确定)。
4.切断主电源,等待显示屏关闭。
航空客票状态认识及辅助指令(终审稿)
航空客票状态认识及辅助指令文稿归稿存档编号:[KKUY-KKIO69-OTM243-OLUI129-G00I-FDQS58-航空客票状态认识及辅助指令1.OPENFORUSE:客票有效2.VOID:已作废3.REFUND:已退票4.CHECKIN:正在办理登机ED/FLOWN:客票已使用6.SUSPENDED:系统处理,或人为挂起禁止使用该票7.PRINT/EXCH:电子客票已换开为纸票(用电子客票票号提出显示)8.LIFTBOARDED:已登机航班离港9.FIMEXCH:已签转航空公司,机场在发生不正常航班时,使用FIM单(FlightInterruptManifest中断飞行舱单)进行航空公司间签转手续10.PAPERTICKET此票为用电子客票换开的纸票(用纸票票号提出显示)11.EXCHANGED电子客票已换开为其他客票12.STATUS=A(AirportControl)—机场控制状态。
此状态下,航空公司持有该票联控制权,客票状态无法被第三方更改;如需更改必须向航空公司申请。
13.STATUS=B、STATUS=O(OpenForUse)—客票可用,机票已经办理了登机手续后才出现航班延误等,如果要退票,要叫航空公司把状态改过来才可以做退票的。
14.STATUS=C(Checked-In)—旅客已值机15.STATUS=E(Exchanged/Reissued)—客票已换开做重新出票16.STATUS=F(Flown/Used)—客票已使用17.STATUS=G(Exchanged/FIM)—客票因中转需要已由机场地服换开18.STATUS=L(Lifted/Boarded)—旅客已登机19.STATUS=R(Refunded)—客票已退20.STATUS=S(Suspended)—客票已挂起,当前无法进行其他操作21.STATUS=U(Unavailable)—客票不可用22.STATUS=V(Void)—客票已作废23.STATUS=X(PrintExchange)—客票已换开为纸票出错信息索引ACTION 行动代码不正确AIRLINE 航空公司代码不正确AMOUNT 数量,通常指FC、FN中的票价输入不正确 AUTHORITY 权限CASH COLLECTION(SCNY.)LOST FN中缺少SCNY项CHECK CONTINUITY 检查航段的连续性,使用@I,或增加地面运输航段COMMISSION(C.)LOST FN中缺少代理费率项CONTACT ELEMENT MISSING 缺少联系组,将旅客的联系电话输入到PNR中CURRENCY 货币代码不正确DATE 输入的日期不正确.DEVICE 打票机序号不正确DUP ID PNR中某项重复,或缺少旅客标识ELE NBR 序号不正确FLT NUMBER 航班号不正确FORMAT 输入格式不正确ILLEGAL 不和法INACTIVE 检查打票机各项状态INFANT 缺少婴儿标识INPUT 打票机的输入状态INVALID CHAR 存在非法字符,或终端参数设置有误ITINERARY DOES NOT MATCH FCFC与PNR中的航程不符MANUAL 手工出票MAX TIME FOR EOT - IGNORE PNR AND RESTART建立了航段组,但未封口的时间超过5分钟,这时系统内部已经做了IG,将座位还原,营业员应做IG,并重新建立PNRNAME LENGTH 姓名超长或姓氏少于两个字符NAMES PNR中缺少姓名项NO DISPLAY 没有显示NO NAME CHANGE FOR MU/Y某航空公司不允许修改姓名NO QUEUE 说明该部门此类信箱不存在OFFICE 部门代号不正确OUTPUT 打票机的输出状态PENDING 表示有未完成的旅客订座PNR,在退号前必须完成或放弃它。
FC(NES)修改教程
FC(NES游戏修改基础教程14 号拐角一、序言在童年时期,很多人或许对于FC的回忆有许许多多,我也不例外,不过说实在话,我在家能玩到的FC游戏非常的少,回忆起来也只有几个,坦克大战,魂斗罗,赤色要塞,沙罗曼蛇……当然最经典的还是小时候玩的热血格斗……之后就由于种种原因再也没有接触了,直到PC的出现,我又重温了那些经典。
但是每每看到网上各种HACK版本,总是希望自己也能做点什么修改,所以各种找教程,各种翻资料……可能对于FC这种已经淘汰的游戏没有很多人关心一样,教程的东西也像烟雾弹一般,可以忽略一样 .....................但是对于已经进入迷途的我,似乎有种由衷的爱好般……我教过一些人,但是总觉得自己的方法或许不得当,教不会,今天写出这些东西,希望能遇到一些有天赋的人,如果能遇到给予我批评指出的人或许会更好。
我不能保证我100%全对,有误的地方希望大家能更正吧。
好吧,或许大家都不喜欢看废话,于是我们开始吧……二、基础修改修改,当然要准备工具,这里我推荐一个非常强大的FC模拟器一一FCEUX 系列,现在最新版本是2.1.6 吧(在我打这篇文章的时候),它提供了非常齐全完善的调试器和16进制编辑器。
当然,如果要修改FC贴图的话可以用很多FC 贴图修改器进行修改,网上应该有很多,这里我找不到好的东西,大伙可以自己找找吧,我主要是讲解游戏内容的修改,而不是贴图修改。
好吧,我们开始修改我修改到恶心的游戏——魂斗罗。
对于这一段,感谢小粽子以前的教诲。
魂斗罗很经典,可能到今天都没有人能够一命通关,对于这些头疼的玩家,我们就给他几个选项。
1、无限命;2、无限金身;3、瞬秒敌人(不推荐修改,有点偏高端)。
友情提示,以下16进制编辑器中,在查看菜单有NES内存、PPU内存、ROM 文件,所以在进行修改之前,请注意自己所在那一页,以免修改错误导致没有相应的效果出现。
只有NES内存和PPU内存才能右键,但是在NES内存下无法进行修改,一改变之后数值会立即转变成为没有修改的状态,注意好自己所在页。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
F C F C参数设置中文说
明
公司内部档案编码:[OPPTR-OPPT28-OPPTL98-OPPNN08]
FC105、FC106参数设置中文说明
1、FC105
SCALE功能接受一个整型值(IN),并将其转换为以工程单位表示的介于下限和上限(LO_LIM和HI_LIM)之间的实型值。
将结果写入OUT。
SCALE 功能使用以下等式:
OUT = [ ((FLOAT (IN) -K1)/(K2-1)) * (HI_LIM-O_LIM)] + LO_LIM
常数K1和K2根据输入值是BIPOLAR还是UNIPOLAR设置。
BIPOLAR:假定输入整型值介于 7648与27648之间,因此K1 = ,K2 = +
UNIPOLAR:假定输入整型值介于0和27648之间,因此K1 = ,K2 = +
如果输入整型值大于K2,输出(OUT)将钳位于HI_LIM,并返回一个错误。
如果输入整型值小于K1,输出将钳位于LO_LIM,并返回一个错误。
通过设置LO_LIM > HI_LIM可获得反向标定。
使用反向转换时,输出值将随输入值的增加而减小。
FC105参数
参数说明数据类型存储区描述
EN 输入 BOOL I、Q、M、D、L 使能输入端,信号状态为1时激活该功能。
ENO 输出 BOOL I、Q、M、D、L 如果该功能的执行无错误,该使能输出端信号状态为1。
IN 输入 INT I、Q、M、D、L、P、常数欲转换为以工程单位表示的实型值的输入值。
HI_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示的上限值。
LO_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示的下限值。
BIPOLAR 输入 BOOL I、Q、M、D、L 信号状态为1表示输入值为双极性。
信号状态0表示输入值为单极性。
OUT 输出 REAL I、Q、M、D、L、P 转换的结果。
RET_VAL 输出 WORD I、Q、M、D、L、P 如果该指令的执行没有错误,将返回值W#16#0000。
对于W#16#0000以外的其它值,参见"错误信息"。
错误信息
如果输入整型值大于K2,输出(OUT)将钳位于HI_LIM,并返回一个错误。
如果输入整型值小于K1,输出将钳位于LO_LIM,并返回一个错误。
ENO的信号状态将设置为0,RET_VAL等于W#16#0008。
实例
如果输入的信号状态为1 (激活),则执行SCALE功能。
在本例中,整型值22将转换为介于和之间的实型值,并写入OUT。
如的信号状态所示,该输入值为BIPOLAR。
如果该功能的执行没有错误,ENO和的信号状态将设置为1,RET_VAL等于W#16#0000。
此主题相关图片
2、FC106
UNSCALE功能接收一个以工程单位表示、且标定于下限和上限(LO_LIM和HI_LIM)之间的实型输入值(IN),并将其转换为一个整型值。
将结果写入OUT。
UNSCALE功能使用以下等式:
OUT = [ ((IN-O_LIM)/(HI_LIM-O_LIM)) * (K2-1) ] + K1
,并根据输入值是BIPOLAR还是UNIPOLAR设置常数K1和K2。
BIPOLAR:假定输出整型值介于 7648和27648之间,因此,K1 = ,K2 = +
UNIPOLAR:假定输出整型值介于0和27648之间,因此,K1 = ,K2 = +
如果输入值超出LO_LIM和HI_LIM范围,输出(OUT)将钳位于距其类型(BIPOLAR或UNIPOLAR)的指定范围的下限或上限较近的一方,并返回一
个错误。
FC106参数
参数说明数据类型存储区描述
EN 输入 BOOL I、Q、M、D、L 使能输入端,信号状态为1时激活该功能。
ENO 输出 BOOL I、Q、M、D、L 如果该功能的执行无错误,该
使能输出端信号状态为1。
IN 输入 REAL I、Q、M、D、L、P、常数欲转换为整型值的输
入值。
HI_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示
的上限。
LO_LIM 输入 REAL I、Q、M、D、L、P、常数以工程单位表示
的下限。
BIPOLAR 输入 BOOL I、Q、M、D、L 信号状态1表示输入值为
双极。
信号状态0表示输入值为单极。
OUT 输出 INT I、Q、M、D、L、P 转换结果。
RET_VAL 输出 WORD I、Q、M、D、L、P 如果该指令的执行没有错误,将返回值W#16#0000。
对于W#16#0000以外的其它值,参见"错误信息"。
错误信息
如果输入值超出LO_LIM和HI_LIM范围,输出(OUT)将钳位于距其类型(BIPOLAR或UNIPOLAR)的指定范围的下限或上限较近的一方,并返回一个错误。
ENO的信号状态将设置为0,RET_VAL等于W#16#0008。
实例
如果输入的信号状态为1 (激活),则执行UNSCALE功能。
在本例中,标定于和之间的实型值,将转换为一个整型值,并写入OUT。
如的信号状态所示,该输入值为BIPOLAR。
如果该功能的执行没有错误,ENO和的信号状态将设置为1,RET_VAL等于W#16#0000。
此主题相关图片。