电阻远传压力表
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Pressure gauge with resistance transmitter
仪表由一个弹簧管压力表和一个滑线电阻式传感器组成,当被测压力变化时,弹簧管端产生位移,一方面通过传动系统使指针在度盘上指示相应压力,另一方面带动电刷在电阻上滑行,使被测压力值的变化转换为电阻值的变化,并传至二次仪表上指示相应的压力。
The gauge is formed by a bourdon tube pressure gauge and a adjustable resistance transmitter. When the pressure is changing, the tube end deformed, and the pointer is to show the pressure value through the driving system, at the same time, the brush is slipping on the resistance to transmit the pressure values to resistant values, which is transmited to the secondary gauge to show the relative pressure value.
工作原理
Operating principle
电阻远传压力表
840 主要技术参数840 Specifications
测量介质:对铜合金无腐蚀作用气体或液体Medium: Gas or liquid, whice doesn’t corrode (可与多类化学密封隔离器配 copper alloy (could be used in corrosion
接在各种腐蚀性的环境中使用) environments connected chemical seals.)安装方式:径向直接安装连接螺纹M20×1.5Mounting: Bottom connection direct (或其他螺纹尺寸) thread M20×1.5 or other
精度等级:1.5级Accuracy: 1.5%
外径:150mm Diameter: 150mm
测量范围:正压:0.1MPa……60MPa;Range: Positive pressure 0.1MPa……60MPa;
负压:-0.1~0MPa,-0.1~2.4MPa。
Negative pressure -0.1~0MPa, -0.1~2.4MPa 工作条件:Working condition:
环境温度:-40~70℃Ambient temperature: -40~70℃
相对湿度:≤85%Relative humidity: ≤85%
工作压力:使用温度偏离20±5℃时,其温Working pressure: When working temperature 度附加误差不大于0.4%/10℃ deviates from 20±5℃. the
additional temperature error shall not be more than 0.4%/10℃
滑线电阻发送器技术数据:Technical data of resistance tramsmitter
起始电阻:6~20ΩStart resistance: 6~20Ω
满度电阻:340~400ΩFull scale resistance: 340~400Ω
接线端外加电阻:≤6V Connection end additional resistance: ≤6V
外壳材质:压铸合金铝Case: Cast aluminium alloy
接头材质:铜合金Socket material: Copper alloy
波登管:铜合金Bourdon tube: copper alloy
表盘:铝,白地黑字Dial aluminum: white with black division
指针:铝,黑色Pointer: Aluminium, black
玻璃:普通玻璃Glass: Window glass
仪表几何尺寸
DIMENSIONS
量 程 RANGES
接线示意图 WIRING DIAGRAM
Full scale
Beginning
Earth
Yellow Red
如何选型 HOW TO ORDER。