韩国all sensor压力传感器
First Sensor MLH系列金属压力传感器产品说明书

MLH SeriesAll Metal Pressure SensorsDESCRIPTIONMLH Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature compensated, calibrated and amplified, the MLH is available in 50 psi to 8,000 psi pressure ranges.MLH sensors deliver ±0.25% full scale accuracy Best Fit Straight Line (BFSL) and as low as 2% total error over a temperature range of -40 °C to 125 °C [-40 °F to 257 °F]. Industry standard connectors and process ports are offered for enhanced reliability and user flexibility.The MLH has seven standard output options:A. 0.5 Vdc to 4.5 Vdc ratiometric output from 5 Vdc excitationB. 4 mA to 20 mA current from 9.5 Vdc to 30 Vdc excitationC. 1.0 Vdc to 6.0 Vdc regulated output from 8 Vdc to30 Vdc excitationD. 0.25 Vdc to 10.25 Vdc regulated output from 14 Vdc to30 Vdc excitationE. 0.5 Vdc to 4.5 Vdc regulated output from 7 Vdc to30 Vdc excitationF. 0 mV to 50 mV from 5 Vdc excitationG. 1 Vdc to 5 Vdc output from 8 Vdc to 30 Vdc excitationFEATURES• All metal wetted parts for use in wide variety of fluidapplications• No internal elastomeric seals mean no o-ring compatibilityissues• Amplified outputs eliminate cost of external amplifiers • Input reverse voltage and output short circuit protectionsguard against mis-wiring• Less than 2 ms response time provides accurate, highspeed measurement• Rated IP65 or better for protection from harsh environmentsPOTENTIAL APPLICATIONS • Compressors• Refrigeration and HVAC/R • General industrial • General hydraulics• Multiple transportation applications including braking andalternate fuels • MedicalMLH Series2 /sensingTable 1. Pressure Range Specifications 1(At 25 °C [77 °F] and at rated excitation unless otherwise specified.)psiPressure 50 100 150 200 250 300 500 1000 2000 3000 5000 8000 Proof pressure 150 300 450 600 750 900 1500 2000 4000 6000 7500 12000 Burst pressure 500 1000 1500 2000 2500 3000 5000 10000 20000 30000 30000 30000barPressure 6 10 16 25 40 60 100 160 250 350 500 550 Proof pressure 18 30 48 75 80 120 200 320 500 700 750 825 Burst pressure60 100 160 250 400 600 1000 1600 2068 2068 2068 2068Note:1. Comparable metric units follow same proof and burst specifications.Table 2. Physical and Environmental SpecificationsParameter Characteristic Material in contact with media stainless steel 300 series and Haynes 214 alloy, Hastelloy C22 sensor available (contact factory) Housing material black plastic – Amodel AS-4133 HS – PPA Weight 57.0 g [2.0 oz] (typical for Packard MetriPak and 1/8 NPT port) Shock 100 g peak [11 ms] Vibration MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V, Random Vibration Test [overall g rms =20.7 min.]Compensated, operating and storage temperature range-40 °C to 125 °C [-40 °F to 257 °F]Table 3. Electrical Specifications (At 25 °C [77 °F] and at rated excitation unless otherwise specified.) Parameter Ratiometric(A)1 Current (B) Regulated(C) Regulated(D) Regulated(E) mV (F) Regulated(G) Zero output 0.5 Vdc4.0 mA1.0 Vdc0.25 Vdc0.5 Vdc0 ±2.5 mV1.0 VdcFull scale span (FSS) 4.0 Vdc (0.5 to 4.5 Vdc) 16 mA (4 to 20 mA) 5.0 Vdc (1.0 to 6.0 Vdc) 10.0 Vdc (0.25 to 10.25 Vdc) 4.0 Vdc (0.5 to4.5 Vdc) 50 mV (0 to 50 mV) 4.0 Vdc (1.0 to 5.0 Vdc)Excitation 5 Vdc (6.0 Vdc max.) 9.5 Vdc to 30.0 Vdc 8.0 Vdc to 30.0 Vdc 14.0 Vdc to 30.0 Vdc 7.0 Vdc to 30.0 Vdc5.0 Vdc (6.0 Vdc max.)8.0 Vdc to 30.0 VdcSupply current 4.0 mA typical (8 mA max.)N/A 5.0 mA typical (17 mA max.)5.0 mA typical (17 mA max.)5.0 mA typical (17 mA max.) 8.0 mA typical (17 mA max.) 5.0 mA typical (17 mA max.)Source (nominal) 1.0 mA N/A 1.0 mA 1.0 mA 1.0 mA N/A 1.0 mA Sink(nominal) 1.0 mA at zero outputN/A 1.0 mA at zero output1.0 mA at zero output1.0 mA at zero outputN/A 1.0 mA at zero outputSupplyrejection ratio 90 db 90 db 90 db 90 db 90 db N/A90 dbOutput impedance25 Ω max.N/A25 Ω max.25 Ω max.25 Ω max.2000 Ω 25 Ω max.Note:1. Maintains ratiometricity at 5 ±0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage.All Metal Pressure SensorsHoneywell Sensing and Control 3Table 4. Performance Specifications (At 25 °C [77 °F] and at rated excitation unless otherwise specified.)Parameter Characteristic Response time <2 msAccuracy 1:>100 psi<100 psi±0.25% FSS ±0.50% FSS Total error band 2:Gage:<300 psig>300 psigSeal gage:>300 psisSeal gage without L, M, P termination:100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F])100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F])>300 psis (-40 °C to 125 °C [-40 °F to 257 °F])Seal gage with L, M, P termination:100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F])100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F])>300 psis (-40 °C to 65 °C [-40 °F to 149 °F])>300 psis (>65 °C to 125 °C [>149 °F to 257 °F])±3% FSS ±2% FSS ±2% FSS ±3% FSS ±10% FSS ±2% FSS ±10% FSS ±15% FSS ±5% FSS ±15% FSS Notes:1. Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included.2. Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity,pressure hysteresis and non-repeatability.1Sensing and Control Honeywell1985 Douglas Drive North Golden Valley, MN 55422 /sensing 008118-5-EN IL50 GLO Printed in USAJanuary 2009Copyright © 2009. Honeywell International Inc. All rights reserved.Figure 2. Mounting Dimensions (For reference only. mm/(in).)Pin and Wire Codes (Option B – Packard)Pin Voltage Current a + Excitation + Excitation b Output - Excitation c Common No ConnectionA variety of pressure ports and electricaltermination connection options are available. Refer to the “How to Order” on previous page for possible combinations. Contact your Honeywell representative for details.WARNINGMISUSE OF DOCUMENTATION• The information presented in this product sheet is forreference only. Do not use this document as a product installation guide.• Complete installation, operation, and maintenanceinformation is provided in the instructions supplied with each product.Failure to comply with these instructions could result in death or serious injury.WARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. Theforegoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While we provide application assistance personally,through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.Specifications may change without notice. Theinformation we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.WARNINGPERSONAL INJURYDO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.Failure to comply with these instructions could result in death or serious injury.SALES AND SERVICEHoneywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or:E-mail:*********************Internet: /sensingPhone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 F ax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 F ax。
Sensata Technologies 压力传感器产品简介说明书

Temperature FunctionWORLD CLASSPERFORMANCESensata Technologiesoffers a wide range ofsensing solutions forpressure applications ofevery kind. By focusingour unparalleledengineering and manu-facturing expertise onyour needs, we willmeet the highestexpectations of all -your own.Sensata Technologiesis the world’s leadingsupplier of sensors andcontrols across a broadrange of markets andapplications.WORLD CLASS PERFORMANCE The CP Series’ pressure transducers with their proven ceramiccapacitive technology have been on the market for many years.Our large portfolio with a variety of mechanical and electrical connec-tions creates a broad range of combination possibilities.50.5 (2)73.8 max (2.9)57.9 max (2.3)35.6 max (1.8)ø 24.3 (0.96)8.2 (0.3)3.6 (0.14)40.2 (1.6)30.4 (1.2)Sensata Technologies is the world’s leading supplier of sensors and controls across a broad range of markets and applications.WORLD CLASS 65.0 (2.56)45.6 (1.8)23.9 (0.94)Pressure outputGroundSupply voltageThermistor outputFeatures and benefits• Hermetic pressure sensors with multiple Input/Output options • High accuracy and repeatability • Multiple standard and custom ports • Outstanding EMC performance and high dielectric strengthTypical applications• Air conditioning• Alternative energy management • Compressors and pumps • Hydraulics and pneumatics• Processing control and automation • Vending machinesWORLD CLASS PERFORMANCE The CH Series’ pressure transducers are ideally suited for the most demanding industrial applications. This innovative product is hermetic but not oil-filled and boasts case isolation up to 1800 V.Ground57.2 (2.25)Aø 31.8 (1.25)Power terminalAOuput terminalø 27.4 (1.08)Sensata Technologies is the world’s leading supplier of sensors and controls across a broad range of markets and applications.Technical specificationsWORLD CLASS PERFORMANCE The PP Series’ pressure transducers allow for the best control in an industrial system. A piezo-resistive technology has been selected, whereby the strain gauges are glass fused onto a metal membrane and hermetically sealed.Small Form Factor 30.1 (1.19)ø 13 (0.51)31.7 (1.25)30 m a x (1.18)40 max (1.58)28 (1.10) 26.8 max (1.06)ø 6 (0.24)Sensata Technologies is the world’s leading supplier of sensors and controls across a broad range of markets and applications.WORLD CLASS PERFORMANCE The most accurate technologies for a true Differential Pressure Sensor are Micro-Electro-Mechanical-Systems (MEMS). Our patented MEMSproducts offer the best-value solutions for differential pressure applications.23 (0.9)ø 6 (0.24)23 (0.9)ø 8 (0.32)20 (0.8)71 (2.8)12.6 (0.5)Supply Voltage GroundOutput signal6 (0.24)Sensata Technologies is the world’s leading supplier of sensors and controls across a broad range of markets and applications.Seal material compatibility guideSeal material Media compatibility (please contact Sensata for more information)Maximum seal temperature range*petroleum oils, lubricants, detergent solutionssteam soaps, polar solvents, brake fluid, acetone Skydrol TM chlorinated solvents, oils, fuels, air Pressure connections(please contact Sensata for other connections)27.6 (1.09)Packard Metri-PackAMP MQS - 3 pins 1/4” - 18 NPTF male1/8” - 27 NPTF male1/4” SAE female flare with deflator (7/6” - 20 UNF - 2B)ø 17 (0.67)Electrical connections(please contact Sensata for other connections)16.4 (0.65)23.5 (0.95)34.4 (1.35)DIN 7258519.6 (0.77)ø 23.6 (0.93)12.9 (0.51)26.4 (1.04)34.1 (1.34)3/8” - 24 UNF male1/4” - 19 BSPT male25.1 (0.99)20 (0.79)10.9 (0.43)7 (0.28)14.5 (0.57)24.3 (0.96)9.8 (0.39)14.5 (0.57)8.9 (0.35)VDA13.8 (0.54)27.1 (1.07)7/16” - 20 UNF maleHex 17.5 (0.69)14.6 (0.58)Hex 17.5 (0.69)11.4 (0.45)Hex 15.7 (0.62)9.5 (0.38)M12 x 1 maleM12 x 1.5 maleM14 x 1.5 male13.7 (0.54)16.2 (1.48)11.3 (0.45)10.3 (0.41)9.8 (0.39)M10 x 1.25 female M18 x 1.5 male 10 (0.39)Hex 14 (0.55)12.7 (0.5)14 (0.55)12 (0.47)12 (0.47)6.9 (0.27)13.2 (0.84)12 (0.47)15.5 (0.6)18 (0.71)19.3 (0.76)19.9 (0.78)14.3 (0.56)11.1 (0.44)17.5 (0.69)6.4 (0.25)Hex 15.9 (0.63)12.7 (0.5)9.2 (0.36)Note: Dimensions are shown in mm (inches)Note: Dimensions are shown in mm (inches)10.6 (0.42)12.7 (0.5)15.3 (0.6)10.3 (0.41)Yazaki10.4 (0.41)21.8 (0.96)RD22.3 (0.88)70.1 (2.76)Sensata Technologies Holland B.V. Kolthofsingel 87602 EM ALMELOThe NetherlandsPhone: +31 546 879555Fax:+31 546 870535 Important Notice: Sensata Technologies (Sensata) reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Sensata advises its customers to obtain the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current. Sensata assumes no responsibility for infringement of assistance or product specifications since Sensata does not possess full access concerning the use or application of customers' products. Sensata also assumes no responsibil-ity for customers' product design.。
Amphenol NovaSensor NPA压力传感器说明书

Healthcare Application Spaces
• Sleep apnea - CPAP • Critical care ventilators • Anesthesia machines • Compression therapy • Air mattresses • Wound management • First responder equipment • Blood pressure
NPA Application Guide:
• /en/component/edocman/312-novasensor-npa-applicationguide/download?Itemid=8007%20%27
NPA Product Brochure:
• Analog Output: • 0.5-3.0Vdc output (3.3Vdc supply) • 0.5-4.5Vdc output (5.0Vdc supply) • 100mV output (5.0Vdc or 1.5mA supply)
• Fast Response Time • <0.5ms sample time for I2C NPA • <2 ms sample time for Analog NPA
6/ Copyright © 2015 Amphenol. All rights reserved.
/en/products/pressure-mems/mems-sensors/3161npa-pressure-sensor
Lowest profile SOIC Package
(3.3Vdc supply) (5.0Vdc supply) (5.0Vdc or 1.5mA supply)
Honeywell 压力传感器(Jackson Union压力传感器)产品说明书

(casing and cementing) are vital oil and gas processes that utilize pressure sensors for measurement and monitoring functions.APPLICATIONSHoneywell Wing Union pressure sensors (also known as Hammer Union pressure sensors outside of the United States) are widely used by oil and gas companies to measure pressure level changes in media circulation systems.Oil Mud LoggingFor example, oil mud loggingapplications (see Figure 1) require a series of pressure sensors to be connected to the drilling apparatus and installed in specialized equipment to monitor or “log” the drill’s activity. Logging While Drilling (LWD) and Measurement While Drilling (MWD)pump into the well), mud pumps (for pressure monitoring of incoming and outgoing media to protect the mudpump and drill bit), and return line choke manifold (for pressure monitoring of the return line carrying the mud plus cuttings).During the mud logging process, pumps send drilling media throughout the circulation system, down to the drilling bit, and then return the bit’s cuttings to the surface for analysis and disposal. Honeywell’s wing union/hammer union pressure sensors help detect pressure level changes in the media circulation system, which can indicate changing conditions being encountered downhole by the drill bit, thus allowing the operator to quickly make adjustments to the drilling mixture pressure or drilling process as needed.today’s oil and gas industry, used for many types Models 434, 435, 437 Wing Union/ Hammer Union Pressure TransducerPRESSURE SENSORS FOROIL & GASApplication NoteFracturing, Acidizing, and Cementing Honeywell’s Wing Union/Hammer Union pressure sensors are also used during fracturing, acidizing, and cementing applications for similar pressure monitoring and control purposes.SOLUTIONSHoneywell Wing Union/Hammer Union Pressure Sensors are built ruggedand oilfield tough to stand up to the rigorous demands of oil and gas drilling applications and environments. They have the sensitivity to ensure precise, reliable measurements every time, optimize drilling operation, reduce downtime, and maximize productivity. Durable ConstructionModels 434, 435, and 437 are constructed on Honeywell’s time proven all-welded, one-piece design, with the sensor diaphragm and Weco® 1502, 2202 Wing Union compatible fitting form factor machined as one part. This one-piece design provides a hermetically sealed unit, reducing the chanceof media leakage into the sensitive electronic components, and increasing overall reliability. The isolated, pressure sensing diaphragm minimizes zero-shift during hammer up and also eliminates long term, signal drift in the field, making it easier to install and providing reliable pressure readings over time.The sensor diaphragm is machined from Inconel® 718, which provides additional durability with highly abrasive and corrosive media, and is weldedto the main stainless steel body. The stainless steel electrical connection provides enhanced secondary pressure containment, with multiple electricalconnector options from which to choose.Optional 1-Wire or 2-Wire ShuntCalibrationModels 434, 435, and 437 providean optional 1-wire or 2-wire shuntcalibration. When a customer sends asignal to the wing union/hammer unionfrom their instrumentation, anothersignal will be returned to validate thefunctionality of the unit. This providesconfidence in the pressure readingsduring normal operation.Optional Protective CageModels 434, 435, and 437 are alsoavailable with an optional protectivecage which provides extra electricalconnection protection and durability.Various Accuracy Levels• Model 434: 0.2 %FSS BFSL• Model 435: High accuracy±0.1 %FSS BFSL orstandard accuracy ±0.2 %FSS BFSL• Model 437: Standard accuracy±0.2 %FSS BFSLModel 437 feature a wider aperturedesign than the other models that isuseful for customers utilizing moreviscous media in certain applications,enabling uniform flow of differentviscous media through the criticalsensing area and helping to maintainconsistent accuracy.*Best Fit Straight LineBENEFITS• Higher ±0.1 %FSS BFSL Accuracy(Model 435): Provides additionalconfidence in the actual measuredpressure value, particularly forsmaller changes in pressure, thusallowing the operator to makequicker adjustments to drillingoperations for more precise controland increased efficiency duringextraction• Wider Aperture Design (Model 437):Wider than Models 434 and 435,helping to prevent media cloggingwhen using more viscous mediablends• Reliability/Durability: All-welded,hermetically sealed, stainless steelconstruction with Inconel® 718wetted parts isolate corrosive orabrasive drilling media from sensitiveinternal electronics; materials retainstrength in higher temperatures toprovide reliable performance underdemanding conditions; shock andvibration tested, intrinsically saferating• Easy Installation/Serviceability:Designed for quick field installation,including horizontal or verticalmounting; field-repairableconnectors; zero and spanadjustments can be accessed byremoving the electrical connector,thus preventing ingress failures anddeterring tampering; 1-wire or 2-wireshunt calibration allow the user todetermine if the wing union/hammerunion is still functional in the field,or if it has to be removed for service/calibration.2 APPLICATION NOTE | Wing Union/Hammer Union Pressure Transducers | /astAPPLICATION NOTE | Wing Union/Hammer Union Pressure Transducers | /ast 3SELECTION GUIDEHoneywell offers three models from which to choose:üüü üüü üüü* Note: See Wing Union pressure sensor datasheet for more agency approval classifications.For more information about Wing Union/Hammer Union pressure sensors, including nomenclature and dimensional drawings, see our datasheet.008875-6-EN | 6 | 10/21© 2021 Honeywell International Inc. All rights reserved.HoneywellAdvanced Sensing Technologies 830 East Arapaho Road Richardson, TX 75081WARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicablewarranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application.Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing.However, Honeywell assumes no responsibilityfor its use.FOR MORE INFORMATIONHoneywell Advanced Sensing Technolo-gies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit /ast or call:USA/Canada +302 327 8920Latin America +1 305 805 8188Europe +1 302 327 8920Japan +81 (0) 3-6730-7152Singapore +65 6355 2828Greater China+86 4006396841。
All Sensors系列压力传感器

型号厂家数量单价封装备注0.25 INCH-D-4V All Sensors1000标封原装正品0.3 PSI-D-4V All Sensors1000标封原装正品0.3 PSI-D-4V-MIL All Sensors1000标封原装正品0.3 PSI-D-4V-PRIME All Sensors1000标封原装正品0.3 PSI-D-CGRADE-MINI All Sensors1000标封原装正品0.3 PSI-D-CGRADE-MV All Sensors1000标封原装正品0.3 PSI-D-HGRADE-MINI All Sensors1000标封原装正品0.3 PSI-D-HGRADE-MV All Sensors1000标封原装正品0.3 PSI-D-PRIME-MINI All Sensors1000标封原装正品0.3 PSI-D-PRIME-MV All Sensors1000标封原装正品0.3 PSI-G-4V All Sensors1000标封原装正品0.3 PSI-G-4V-MIL All Sensors1000标封原装正品0.3 PSI-G-4V-PRIME All Sensors1000标封原装正品0.3 PSI-G-4V-PRIME-REF All Sensors1000标封原装正品0.3 PSI-G-CGRADE-MINI All Sensors1000标封原装正品0.3 PSI-GF-CGRADE-MINI All Sensors1000标封原装正品0.3 PSI-GF-HGRADE-MINI All Sensors1000标封原装正品0.3 PSI-GF-PRIME-MINI All Sensors1000标封原装正品0.3 PSI-G-HGRADE-MINI All Sensors1000标封原装正品0.3 PSI-G-PRIME-MINI All Sensors1000标封原装正品0.3PSI-D-4V All Sensors1000标封原装正品0.3PSI-D-CGRADE-MV All Sensors1000标封原装正品0.3PSI-D-HGRADE-MINI All Sensors1000标封原装正品0.3PSI-D-HGRADE-MV All Sensors1000标封原装正品0.3PSI-D-PRIME-MV All Sensors1000标封原装正品0.3PSI-G-4V All Sensors1000标封原装正品0.3PSI-GF-HGRADE-MINI All Sensors1000标封原装正品0.3PSI-G-HGRADE-MINI All Sensors1000标封原装正品0.5 INCH-G-4V All Sensors1000标封原装正品1 INCH-D1-BASIC All Sensors1000标封原装正品1 INCH-D2-BASIC All Sensors1000标封原装正品1 INCH-D-4V All Sensors1000标封原装正品1 INCH-D-4V-MIL All Sensors1000标封原装正品1 INCH-D-4V-PRIME All Sensors1000标封原装正品1 INCH-D-MV All Sensors1000标封原装正品1 INCH-G P4V-MINI All Sensors1000标封原装正品1 INCH-G-4V All Sensors1000标封原装正品1 INCH-G-4V-MIL All Sensors1000标封原装正品1 INCH-G-4V-PRIME All Sensors1000标封原装正品1 INCH-G-BASIC All Sensors1000标封原装正品1 MBAR-D-4V All Sensors1000标封原装正品1 MBAR-D-4V-MIL All Sensors1000标封原装正品1 MBAR-D-4V-PRIME All Sensors1000标封原装正品1 PSI-D-4V All Sensors1000标封原装正品1 PSI-D-4V-MIL All Sensors1000标封原装正品1 PSI-D-4V-PRIME All Sensors1000标封原装正品1 PSI-D-CGRADE-MV All Sensors1000标封原装正品1 PSI-D-DO All Sensors1000标封原装正品1 PSI-D-DO-MIL All Sensors1000标封原装正品1 PSI-D-HGRADE-MINI All Sensors1000标封原装正品1 PSI-D-HGRADE-MV All Sensors1000标封原装正品1 PSI-D-PRIME-MINI All Sensors1000标封原装正品1 PSI-D-PRIME-MV All Sensors1000标封原装正品1 PSI-G-4V All Sensors1000标封原装正品1 PSI-G-4V-MIL All Sensors1000标封原装正品1 PSI-G-4V-PRIME All Sensors1000标封原装正品1 PSI-G-4V-PRIME-REF All Sensors1000标封原装正品1 PSI-G-CGRADE-MINI All Sensors1000标封原装正品1 PSI-GF-CGRADE-MINI All Sensors1000标封原装正品1 PSI-GF-HGRADE-MINI All Sensors1000标封原装正品1 PSI-GF-PRIME-MINI All Sensors1000标封原装正品1 PSI-G-HGRADE-MINI All Sensors1000标封原装正品1 PSI-G-PRIME-MINI All Sensors1000标封原装正品10 INCH-D1-4V-MINI All Sensors1000标封原装正品10 INCH-D1-BASIC All Sensors1000标封原装正品10 INCH-D1-MV-MINI All Sensors1000标封原装正品10 INCH-D1-P4V-MINI All Sensors1000标封原装正品10 INCH-D2-4V-MINI All Sensors1000标封原装正品10 INCH-D2-BASIC All Sensors1000标封原装正品10 INCH-D2-MV-MINI All Sensors1000标封原装正品10 INCH-D2-P4V-MINI All Sensors1000标封原装正品10 INCH-D-4V All Sensors1000标封原装正品10 INCH-D-4V-MIL All Sensors1000标封原装正品10 INCH-D-4V-PRIME All Sensors1000标封原装正品10 INCH-D-CGRADE-MINI All Sensors1000标封原装正品10 INCH-D-DO All Sensors1000标封原装正品10 INCH-D-DO-MIL All Sensors1000标封原装正品10 INCH-D-HGRADE-MINI All Sensors1000标封原装正品10 INCH-D-MV All Sensors1000标封原装正品10 INCH-D-PRIME-MINI All Sensors1000标封原装正品10 INCH-G-4V All Sensors1000标封原装正品10 INCH-G-4V-MIL All Sensors1000标封原装正品10 INCH-G-4V-MINI All Sensors1000标封原装正品10 INCH-G-4V-PRIME All Sensors1000标封原装正品10 INCH-G-BASIC All Sensors1000标封原装正品10 INCH-G-CGRADE-MINI All Sensors1000标封原装正品10 INCH-GF-CGRADE-MINI All Sensors1000标封原装正品10 INCH-GF-HGRADE-MINI All Sensors1000标封原装正品10 INCH-GF-PRIME-MINI All Sensors1000标封原装正品10 INCH-G-HGRADE-MINI All Sensors1000标封原装正品10 INCH-G-MV-MINI All Sensors1000标封原装正品10 INCH-G-P4V-MINI All Sensors1000标封原装正品100 PSI-A-DO All Sensors1000标封原装正品100 PSI-A-DO-MIL All Sensors1000标封原装正品100 PSI-D-CGRADE-MV All Sensors1000标封原装正品100 PSI-D-HGRADE-MV All Sensors1000标封原装正品100 PSI-D-PRIME-MV All Sensors1000标封原装正品100 PSI-G-DO All Sensors1000标封原装正品100 PSI-G-DO-MIL All Sensors1000标封原装正品100PSI-D-4V-ASCX All Sensors1000标封原装正品10INCH-D1-BASIC All Sensors1000标封原装正品10INCH-D1-MV-MINI All Sensors1000标封原装正品10INCH-D2-BASIC All Sensors1000标封原装正品10INCH-D2-MV-MINI All Sensors1000标封原装正品10INCH-D-4V All Sensors1000标封原装正品10INCH-D-DO All Sensors1000标封原装正品10INCH-D-HGRADE-MINI All Sensors1000标封原装正品10INCH-D-MV All Sensors1000标封原装正品10INCH-G-4V All Sensors1000标封原装正品10INCH-G-4V-REF All Sensors1000标封原装正品10INCH-G-BASIC All Sensors1000标封原装正品10INCH-GF-HGRADE-MINI All Sensors1000标封原装正品10INCH-G-HGRADE-MINI All Sensors1000标封原装正品10INCH-G-MV-MINI All Sensors1000标封原装正品120 CMH2O-D1-4V-MINI All Sensors1000标封原装正品120 CMH2O-D1-P4V-MINI All Sensors1000标封原装正品15 PSI-A-4V All Sensors1000标封原装正品15 PSI-A-4V-MIL All Sensors1000标封原装正品15 PSI-A-4V-PRIME All Sensors1000标封原装正品15 PSI-A-CGRADE-MINI All Sensors1000标封原装正品15 PSI-A-CGRADE-MV All Sensors1000标封原装正品15 PSI-A-DO All Sensors1000标封原装正品15 PSI-A-DO-MIL All Sensors1000标封原装正品15 PSI-AF-CGRADE-MINI All Sensors1000标封原装正品15 PSI-AF-HGRADE-MINI All Sensors1000标封原装正品15 PSI-AF-PRIME-MINI All Sensors1000标封原装正品15 PSI-A-HGRADE-MINI All Sensors1000标封原装正品15 PSI-A-HGRADE-MV All Sensors1000标封原装正品15 PSI-A-PRIME-MINI All Sensors1000标封原装正品15 PSI-A-PRIME-MV All Sensors1000标封原装正品15 PSI-D-4V All Sensors1000标封原装正品15 PSI-D-4V-MIL All Sensors1000标封原装正品15 PSI-D-4V-PRIME All Sensors1000标封原装正品15 PSI-D-CGRADE-MINI All Sensors1000标封原装正品15 PSI-D-CGRADE-MV All Sensors1000标封原装正品15 PSI-D-DO All Sensors1000标封原装正品15 PSI-D-DO-MIL All Sensors1000标封原装正品15 PSI-D-HGRADE-MINI All Sensors1000标封原装正品15 PSI-D-PRIME-MINI All Sensors1000标封原装正品15 PSI-D-PRIME-MV All Sensors1000标封原装正品15 PSI-G-4V All Sensors1000标封原装正品15 PSI-G-4V-MIL All Sensors1000标封原装正品15 PSI-G-4V-PRIME All Sensors1000标封原装正品15 PSI-G-4V-PRIME-REF All Sensors1000标封原装正品15 PSI-G-CGRADE-MINI All Sensors1000标封原装正品15 PSI-GF-CGRADE-MINI All Sensors1000标封原装正品15 PSI-GF-HGRADE-MINI All Sensors1000标封原装正品15 PSI-GF-PRIME-MINI All Sensors1000标封原装正品15 PSI-G-HGRADE-MINI All Sensors1000标封原装正品15 PSI-G-PRIME-MINI All Sensors1000标封原装正品15PSI-A-4V All Sensors1000标封原装正品15PSI-A-CGRADE-MV All Sensors1000标封原装正品15PSI-AF-HGRADE-MINI All Sensors1000标封原装正品15PSI-A-HGRADE-MINI All Sensors1000标封原装正品15PSI-A-HGRADE-MV All Sensors1000标封原装正品15PSI-A-PRIME-MV All Sensors1000标封原装正品15PSI-D-4V-ASCX All Sensors1000标封原装正品15PSI-D-CGRADE-MV All Sensors1000标封原装正品15PSI-D-HGRADE-MV All Sensors1000标封原装正品15PSI-G-4V All Sensors1000标封原装正品1INCH-D1-BASIC All Sensors1000标封原装正品1INCH-D2-4V-MINI All Sensors1000标封原装正品1INCH-D2-BASIC All Sensors1000标封原装正品1INCH-D-4V All Sensors1000标封原装正品1INCH-D-MV All Sensors1000标封原装正品1INCH-G-4V All Sensors1000标封原装正品1INCH-G-BASIC All Sensors1000标封原装正品1MBAR-D-4V All Sensors1000标封原装正品1PSI-D-4V All Sensors1000标封原装正品1PSI-D-4V-ASCX All Sensors1000标封原装正品1PSI-D-CGRADE-MV All Sensors1000标封原装正品1PSI-D-HGRADE-MINI All Sensors1000标封原装正品1PSI-D-HGRADE-MV All Sensors1000标封原装正品1PSI-D-PRIME-MV All Sensors1000标封原装正品1PSI-G-4V All Sensors1000标封原装正品1PSI-GF-HGRADE-MINI All Sensors1000标封原装正品1PSI-G-HGRADE-MINI All Sensors1000标封原装正品2 INCH-D1-4V-MINI All Sensors1000标封原装正品2 INCH-D1-MV-MINI All Sensors1000标封原装正品2 INCH-D1-P4V-MINI All Sensors1000标封原装正品2 INCH-D2-4V-MINI All Sensors1000标封原装正品2 INCH-D2-MV-MINI All Sensors1000标封原装正品2 INCH-D2-P4V-MINI All Sensors1000标封原装正品2 INCH-G-4V-MINI All Sensors1000标封原装正品2 INCH-G-P4V-MINI All Sensors1000标封原装正品20 CMH2O-D1-4V-MINI All Sensors1000标封原装正品20 CMH2O-D1-P4V-MINI All Sensors1000标封原装正品20 INCH-D1-4V-MINI All Sensors1000标封原装正品20 INCH-D1-BASIC All Sensors1000标封原装正品20 INCH-D1-MV-MINI All Sensors1000标封原装正品20 INCH-D1-P4V-MINI All Sensors1000标封原装正品20 INCH-D2-4V-MINI All Sensors1000标封原装正品20 INCH-D2-BASIC All Sensors1000标封原装正品20 INCH-D2-MV-MINI All Sensors1000标封原装正品20 INCH-D2-P4V-MINI All Sensors1000标封原装正品20 INCH-D-4V All Sensors1000标封原装正品20 INCH-D-4V-MIL All Sensors1000标封原装正品20 INCH-D-4V-PRIME All Sensors1000标封原装正品20 INCH-D-DO All Sensors1000标封原装正品20 INCH-D-DO-MIL All Sensors1000标封原装正品20 INCH-D-MV All Sensors1000标封原装正品20 INCH-G-4V All Sensors1000标封原装正品20 INCH-G-4V-MIL All Sensors1000标封原装正品20 INCH-G-4V-MINI All Sensors1000标封原装正品20 INCH-G-4V-PRIME All Sensors1000标封原装正品20 INCH-G-4V-REF All Sensors1000标封原装正品20 INCH-G-BASIC All Sensors1000标封原装正品20 INCH-G-MV-MINI All Sensors1000标封原装正品20 INCH-G-P4V-MINI All Sensors1000标封原装正品20 INCH-D1-BASIC All Sensors1000标封原装正品20 INCH-D1-MV-MINI All Sensors1000标封原装正品20 INCH-D2-BASIC All Sensors1000标封原装正品20 INCH-D2-MV-MINI All Sensors1000标封原装正品20 INCH-D-4V All Sensors1000标封原装正品20 INCH-D-MV All Sensors1000标封原装正品20 INCH-G-4V All Sensors1000标封原装正品20 INCH-G-BASIC All Sensors1000标封原装正品20 INCH-G-MV-MINI All Sensors1000标封原装正品2 INCH-D1-MV-MINI All Sensors1000标封原装正品2 INCH-D2-MV-MINI All Sensors1000标封原装正品2 INCH-G-MV-MINI All Sensors1000标封原装正品30 INCH-D1-4V-MINI All Sensors1000标封原装正品30 INCH-D1-BASIC All Sensors1000标封原装正品30 INCH-D1-MV-MINI All Sensors1000标封原装正品30 INCH-D1-P4V-MINI All Sensors1000标封原装正品30 INCH-D2-4V-MINI All Sensors1000标封原装正品30 INCH-D2-BASIC All Sensors1000标封原装正品30 INCH-D2-MV-MINI All Sensors1000标封原装正品30 INCH-D2-P4V-MINI All Sensors1000标封原装正品30 INCH-D-4V All Sensors1000标封原装正品30 INCH-D-4V-PRIME All Sensors1000标封原装正品30 INCH-D-DO All Sensors1000标封原装正品30 INCH-D-DO-MIL All Sensors1000标封原装正品30 INCH-D-MV All Sensors1000标封原装正品30 INCH-G-4V All Sensors1000标封原装正品30 INCH-G-4V-MIL All Sensors1000标封原装正品30 INCH-G-4V-MINI All Sensors1000标封原装正品30 INCH-G-4V-PRIME All Sensors1000标封原装正品30 INCH-G-BASIC All Sensors1000标封原装正品30 INCH-G-MV-MINI All Sensors1000标封原装正品30 INCH-G-P4V-MINI All Sensors1000标封原装正品30 PSI-A-DO All Sensors1000标封原装正品30 PSI-A-DO-MIL All Sensors1000标封原装正品30 PSI-D-4V All Sensors1000标封原装正品30 PSI-D-CGRADE-MV All Sensors1000标封原装正品北京芯联科泰电子有限公司金工。
FESTO SPAB 压力传感器说明书

Pressure sensors SPAB, with displaySubject to change – 2017/102è Internet: /catalog/...Pressure sensors SPAB, with displayKey features, product range overviewAt a glanceVariants:–Plug M8x1 with electric adapter SASC –Plug, square design L1–Cable version with connecting cable NEBSCompact design 30 x 30 mmDisplayable units:–bar –inchH 2O –inchHg –kPa –psi –mmHg –kgf/cm 2–MPaMounting bracket or front panel mounting, threaded mounting Multi-coloured, two-part display High ease of use thanks to intuitive operator promptingAlphanumeric display Country-specific pressure supply ports:–G1/8–R1/8–NPT1/8-27–M5 female threadProduct descriptionMain applicationsKey featuresThe pressure sensor SPAB can be used in many industries thanks to its wide range of connection andconfiguration options and its compact size.Switching point settings are emphasised via switching status indication and switching of the display value colour.Pressure/vacuum sensing Light assemblyWherever there is a need for space-saving pressuremeasurement with visualisation and limited robustnessEasy identification of the system status by means of clear,colour-based switching status detectionPressure measuring range –1 … +1or 0 … 10 barRelative pressure measurement Pressure supply port G1/8, R1/8,NPT1/8-27 or M5 female thread Electrical connection cable, plug M8x1 or plug, square design Switching output PNP, NPN Analogue output 1 … 5 V or 4 … 20 mA, switchableTwo-part, multi-coloured display Copy function (settings can be transferred from one device to another)Simple commissioning thanks to intuitive operationCompact design 30x30 mm-U-Type discontinuedAvailable up until 20172017/10 – Subject to change 3è Internet: /catalog/...Pressure sensors SPAB, with displayKey features, product range overview Mounting optionsFront panel mountingManifold sub-bases via mounting bracketThreaded mounting with adapter M8Product range overview Measurement method Measured variable Pressure measuring rangeSwitching function Pneumatic connection Electrical output [bar]Male thread Female thread Digital AnaloguePiezoresistive pressure sensor with display1x relative pressure–1 ... +1 or 0 (10)FreelyprogrammableG1/8,R1/8 or NPT1/8-27M51x PNP 1 … 5 V / 4 … 20 mA 2x PNP –1x NPN 1 … 5 V / 4 … 20 mA 2x NPN–-U-Type discontinuedAvailable up until 2017Pressure sensors SPAB, with displayPeripherals overviewAccessoriesè Page/Internet1Mounting bracket SAMH-…-A102Adapter plate SASF for pressure sensor SPAB-…-F133Electric adapter SASC-…-A114Front panel installation kit SAMH-…-F10Accessoriesè Page/Internet5Protective cover SACC106Connecting cable NEBU-M8147Connecting cable NEBS-L1G4148Push-in fitting QSM-M514-U-Type discontinuedAvailable up until 2017Subject to change – 2017/10 4è Internet: /catalog/...2017/10 – Subject to change 5è Internet: /catalog/...Pressure sensors SPAB, with displayType codesSPAB–P10R–G18–PB –L1Type SPABPiezoresistive pressure sensor with multi-coloured displayPressure measuring range [bar]B2–1 … +1P100 (10)Pressure input RRelative pressurePneumatic connection G18Male thread G1/8 and female thread M5R18Male thread R1/8 and female thread M5N18Male thread NPT1/8-27 and female thread M5FFor adapter plate, female thread M5Electrical output 2P 2 switching outputs PNP 2N 2 switching outputs NPN PB 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA NB1 switching output NPN1 analogue output 1 … 5 V / 4 … 20 mAElectrical connection L1Plug, L1 design-U-Type discontinuedAvailable up until 2017Subject to change – 2017/106è Internet: /catalog/...Pressure sensors SPAB, with displayTechnical dataFunctionE.g. switching output 2x PNPE.g. switching output NPN, analogueoutput-P-Voltage12 … 24 V DC -L-Pressure –1 … +10 bar -Q-Temperature range–10 … +50 °CGeneral technical data SPAB-B2-P10General information Certificationc UL us - Recognized (OL)RCM trademarkCE mark (see declaration of conformity)To EU EMC Directive 1)Note on materialsContains PWIS (paint wetting impairment substances)RoHS-compliantInput signal/measuring element Measured variable Relative pressureMeasurement method Piezoresistive pressure sensor with display Pressure measuring range [bar]–1 … +10 … 10Overload capacity [bar]515Operating mediumCompressed air in accordance with ISO 85731:2010 [7:4:4]Note on operating/pilot medium Operation with lubricated medium not possible Ambient temperature[°C]–10 … +501)For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: /sp è User documentation.If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.Electrical data SPAB-B2-P10Electrical output2P2N PB NB 2P 2N PB NB Switching output 1)Switching output 2x PNP 2x NPN PNPNPN2x PNP2x NPNPNPNPNSwitching functionFreely programmable Switching element function Switchable Accuracy of FS display[%]12Reproducibility of switching value [%]0.10.2Max. output current [mA]100Analogue output 1)Analogue output[V]– 1 … 5– 1 … 5[mA]– 4 … 20– 4 … 20Accuracy of analogue output zero point ±FS[%]–5–5Accuracy of analogue output margin ±FS[%]–5–5Reproducibility of analogue value [%]–0.2–0.2Output, additional dataProtection against short circuitYes1)% FS = % of the measuring range final value (full scale)-U-Type discontinuedAvailable up until 20172017/10 – Subject to change 7è Internet: /catalog/...Pressure sensors SPAB, with displayTechnical data Electrical data SPAB-B2-P10Electrical output 2P2N PB NB2P2N PB NBOperating voltage range DC [V]12 (24)Reverse polarity protection For all electrical connections Electrical connectionPlug, 4-pin, square designMechanical components SPAB-G18-R18-N18-FType of mounting Screw-inOn adapter plate Via accessories –Pneumatic connection Female thread M5Male thread G1/8Male thread R1/8Male thread NPT1/8-27–Product weight [g]4530Housing materials PBT, reinforcedDisplay/operation SPAB-B2-P10Display type Illuminated LCD, multi-coloured Displayable unitsbar bar inchH 2O –inchHg –kPa kPa psi psi mmHg –kgf/cm 2kgf/cm 2–MPaSwitching status display Yellow LCD Setting optionsTeach-inVia display and keys Tamper protectionPIN code Threshold value setting range [%]0 … 100Hysteresis setting range [%]0 (90)Immissions/emissions Protection classIP40Corrosion resistance class CRC 1)21)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.-U-Type discontinuedAvailable up until 2017Subject to change – 2017/108è Internet: /catalog/...Pressure sensors SPAB, with displayTechnical dataTypeB1D1D2H1H2H3L1L2L3L4L5ßSPAB-…-G18-…-L130G1/8–30––157~25–114SPAB-…-R18-…-L130R1/8–30––149.5~25–112SPAB-…-N18-…-L130NPT1/8–30––149.5~25–112SPAB-…-F-…-L130M5–30––4.4–~25–––-U-Type discontinuedAvailable up until 20172017/10 – Subject to change 9è Internet: /catalog/...Pressure sensors SPAB, with displayTechnical dataOrdering dataPressure measuring range Electrical output Part No.Type[bar]DigitalAnalogueMale thread G1/8 and female thread M5–1 … +1 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000051SPAB-B2R-G18-PB-L12 switching outputs PNP –8000045SPAB-B2R-G18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000054SPAB-B2R-G18-NB-L12 switching outputs NPN–8000048SPAB-B2R-G18-2N-L10 … 10 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000063SPAB-P10R-G18-PB-L12 switching outputs PNP –8000057SPAB-P10R-G18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000066SPAB-P10R-G18-NB-L12 switching outputs NPN –8000060SPAB-P10R-G18-2N-L1Male thread R1/8 and female thread M5–1 … +1 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000052SPAB-B2R-R18-PB-L12 switching outputs PNP –8000046SPAB-B2R-R18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000055SPAB-B2R-R18-NB-L12 switching outputs NPN–8000049SPAB-B2R-R18-2N-L10 … 10 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000064SPAB-P10R-R18-PB-L12 switching outputs PNP –8000058SPAB-P10R-R18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000067SPAB-P10R-R18-NB-L12 switching outputs NPN –8000061SPAB-P10R-R18-2N-L1Male thread NPT1/8-27 and female thread M5–1 … +1 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000053SPAB-B2R-N18-PB-L12 switching outputs PNP –8000047SPAB-B2R-N18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000056SPAB-B2R-N18-NB-L12 switching outputs NPN–8000050SPAB-B2R-N18-2N-L10 … 10 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000065SPAB-P10R-N18-PB-L12 switching outputs PNP –8000059SPAB-P10R-N18-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000068SPAB-P10R-N18-NB-L12 switching outputs NPN –8000062SPAB-P10R-N18-2N-L1For adapter plate, female thread M5–1 … +1 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000071SPAB-B2R-F-PB-L12 switching outputs PNP –8000069SPAB-B2R-F-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000072SPAB-B2R-F-NB-L12 switching outputs NPN–8000070SPAB-B2R-F-2N-L10 … 10 1 switching output PNP1 analogue output 1 … 5 V / 4 … 20 mA 8000075SPAB-P10R-F-PB-L12 switching outputs PNP –8000073SPAB-P10R-F-2P-L11 switching output NPN 1 analogue output 1 … 5 V / 4 … 20 mA 8000076SPAB-P10R-F-NB-L12 switching outputs NPN–8000074SPAB-P10R-F-2N-L1-U-Type discontinuedAvailable up until 2017Subject to change – 2017/1010è Internet: /catalog/...Pressure sensors SPAB, with displayAccessoriesDimensions and ordering data B1B2B3D1H1H2H3H4L1L2L3L4Part No.Type 14.59.54.23.5~44205.5230201322552376SAMH-P4-AOrdering dataB1B2H1L1L2Part No.Type ~317245034.5552377SAMH-P4-FDimensions and ordering dataB1H1H2L1L2Part No.Type ~2834.52039.334.5552378SACC-P4-G2017/10 – Subject to change 11è Internet: /catalog/...AccessoriesDimensions and ordering dataB1D1H1H2L1L2CRC 1)Part No.Type29.6M8x113739.529.628000326SASC-P4-A-M8-A1)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.Subject to change – 2017/1012è Internet: /catalog/...AccessoriesDimensions and ordering dataB1D1H1H2H3L2CRC 1)Part No.Type29.6M8x113716.329.628000327SASC-P4-A-M8-S1)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.AccessoriesSASF-P4-P-M5-H-NoteTo differentiate the adapter plates R1/8, G1/8 and NPT1/8, they are identified as follows at the pneumatic connection:–R1/8No line –NPT1/8 One line –G1/8 Two linesDimensions and ordering dataB1B2B3D1D2∅D3∅H1H2H3H4H5302420R1/84.3 3.452.544.524820 G1/8NPT1/8302420M5 4.3 3.4–44.524–20 H6H7L1L2L3R1ßCRC1)Part No.Type5.56.517.511.58.59142570801SASF-P4-P-R18 570802SASF-P4-P-G18 570803SASF-P4-P-N185.56.517.511.58.59–570804SASF-P4-P-M51)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.2017/10 – Subject to change13è Internet: /catalog/...Accessories14è Internet: /catalog/...Subject to change – 2017/10Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。
JUMO MIDAS C08 OEM 压力传感器 数据表 401002说明书

Page 1/10Data Sheet 401002JUMO MIDAS C08OEM Pressure Transmitter – BasicApplications•compressors•machinery and plant engineering •industrial pneumatics •commercial vehicles •building technologyBrief descriptionThis pressure transmitter is used as the core product for the MIDAS range for applications re-quiring reliable implementation of measuring tasks with long-term stability and excellent price-performance ratio. The MIDAS range provides solutions for all applications on the basis of this core product.The innovative and patented sensor design of the specifically developed ceramic sensor pro-vides excellent long-term stability of <0.2%. It can be used for recording relative pressures of 1.6bar to 60bar in gaseous or liquid media.Type 401002 with QUICKONType 401002 with M12×1 connectorCustomer benefits•process-reliableThrough constructive measures, the pressure transmitter achieves excellent vibration resis-tance and enables application under high vibration load, as occurs in commercial vehicles for example. The throughput through the fully automatic measuring and calibration devices,the diagnostic function of the switching circuit, and the full final inspection complete the high standard of quality.•economicThe QUICKON quick-clamp technology enables quicker and safer installation. The connec-tion is even guaranteed with any temperature fluctuations that may occur thanks to the spring contacts. This electrical connection means that installation times can be shortened and as a result, costs are reduced by 60 % compared to conventional connection options.•versatileThe universal application is reflected by the wide choice of measuring ranges, process con-nections, and electrical connections.Special features•long-term stability <0.2%•new level of quality for the OEM sector •60% quicker device installation with the QUICKON quick-clamp technology •temperature compensation range in-creased by 50 % to -20°C to +100°C • 2.5 times more vibration resistance than the industry standard •made in GermanyApprovals/approval marks (see "Technical data")Page 2/10Data Sheet 401002Technical dataGeneral InformationMeasuring range and accuracyReference conditions DIN 16086 and DIN EN 60770SensorMeasuring principle Thick film on ceramic bodies (piezo-resistive)Admissible load changes >10million, 0to 100% measuring range Mounting position AnyCalibration positionDevice upright, process connection at the bottom Measuring rangeLinearity a Accuracy at Long-term stability b Overload capacity c Burst pressure 20°C d -10to +85°C e -20to +100°C e % MSP f% MSP % MSP % MSP % MSP per year bar bar 0to 1.6bar relative pressure 0.250.50.6510.26120to 2.5bar relative pressure 6120to 4bar relative pressure 0.350.512250to 6bar relative pressure 12250to 10bar relative pressure 20380to 16bar relative pressure 50750to 25bar relative pressure 50750to 40bar relative pressure 1202000to 60bar relative pressure 120200-1to +0.6bar relative pressure 0.50.65612-1to +1.5bar relative pressure 612-1to +3bar relative pressure 0.350.51225-1to +5bar relative pressure 1225-1to +9bar relative pressure 2038-1to +15bar relative pressure 5075-1to +24bar relative pressure5075a Linearity according to limit point settingb Reference conditions EN 61298-1c All pressure transmitters are vacuum-proof.d Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end valuee Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value, thermal effect on mea-suring range start and measuring span fMSP = Measuring spanPage 3/10Data Sheet 401002OutputMechanical featuresAnalog output a Current 4to 20mA, two-wire (output 405)VoltageDC 0.5to 4.5V, three-wire,ratiometric 10to 90% of the voltage supply (output 412)DC 0to 10V, three-wire (output 415)DC 1to 5V, three-wire (output 418)DC 1to 6V, three-wire (output 420)Step response T 90≤2msBurden CurrentR L ≤(U B -8V)÷0.02A (Ω) at 4to 20mA, two-wire (output 405)Voltage(burden connected to "0V/S-")R L ≥5k Ω at DC 0.5to 4.5V, three-wire (output 412)R L ≥10k Ω at DC 0to 10V, three-wire (output 415)R L ≥10k Ω at DC 1to 5V, three-wire (output 418)R L ≥10k Ω at DC 1to 6V, three-wire (output 420)aFurther outputs are available upon request.MaterialProcess connection Stainless steel 304for push-in fitting(process connection 383)Brass, nickel-plated Seal 600 (internal a )EPDM Seal 601 (internal a)FKM, standard Seal 602 (internal a )CR Seal 604 (internal a )FFKM Seal 609 (internal a )NBR for G 1/4 (process connection 521)(external a )FKMSensor Ceramic Al 2O 3 96%HousingStainless steel 304Attached cable(electrical connection 11)PBT-GF30, PVC QUICKON(electrical connection 23)PBT-GF30Round plug M12×1 (electrical connection 36)PBT-GF30, stainless steel 303L Bayonet connector(electrical connection 53)PBT-GF30Cable socket(electrical connection 61)PBT-GF30, PA, siliconeWeight70g with G 1/4 (process connection 502)aEnsure the medium durability of the seal material!Page 4/10Data Sheet 401002Environmental influencesMedium temperature for electrical connection Attached cable -20to +125°C Round plug M12×1-20to +125°C Bayonet connector -20to +125°C Cable socket -20to +125°CAmbient temperature for electrical connection Attached cable-20to +100°CAt ambient temperature of -30°C restricted function. Only use when stationary. Risk of cable break.Round plug M12×1-20to +100°C Bayonet connector -20to +100°C Cable socket -20to +100°C Storage temperature for electrical connection Attached cable -30to +100°C Round plug M12×1-40to +100°C Bayonet connector -40to +100°C Cable socket -40to +100°CAdmissible humidity Operation 100% rel. humidity including condensation on the device outer case Storage90% rel. humidity without condensationAdmissible mechanical load Vibration resistance 50g for 10to 2000Hz, according to IEC 60068-2-6Shock resistance50g for 3ms, 100g for 2ms, according to IEC 60068-2-27Electromagnetic compatibility according to EN 61326-2-3Interference emission Class B aInterference immunity Industrial requirement Protection typefor electrical connection according to EN 60529Attached cable IP67QUICKON b IP67Round plug M12×1cIP67Bayonet connector c IP67Cable socket c, dIP65a The product is suitable for industrial use as well as for households and small businesses.b Connecting cable diameter, minimum 3.5mm, maximum 6mmc The protection type is only achieved with a suitable mounted counter piece.dConnecting cable diameter, minimum 6mm, maximum 8mmPage 5/10Data Sheet 401002Auxiliary powerApprovals/approval marksVoltage supply U B a4to 20mA, two-wire (output 405)DC 8to 30V, rated voltage supply DC 24V DC 0.5to 4.5V, three-wire (output 412)DC 3to 5.25V, rated voltage supply DC 5V,ratiometric output 10to 90% of the voltage supply DC 0to 10V, three-wire (output 415)DC 11.5to 30V, rated voltage supply DC 24V DC 1to 5V, three-wire (output 418)DC 8to 30V, rated voltage supply DC 24V DC 1to 6V, three-wire (output 420)DC 8to 30V, rated voltage supply DC 24V Current consumption incl. load 4to 20mA, two-wire (output 405)≤25mA DC 0.5to 4.5V, three-wire (output 412)≤3mA DC 0to 10V, three-wire (output 415)≤3mA DC 1to 5V, three-wire (output 418)≤3mA DC 1to 6V, three-wire (output 420)≤3mA Reverse voltage protection Yes Electrical circuit SELVRequirementsThe device must be equipped with an electrical circuit that meets the requirements of EN 61010-1 with regardto "Limited-energy circuits".aResidual ripple: the voltage peaks must not exceed or fall below the specified voltage supply values!Approval mark Testing agency Certificate/certification num-ber Inspection basisValid forc UL usUnderwriters LaboratoriesE201387UL 61010-1 (3. Ed.),CAN/CSA-22.2No.61010-1(3. Ed.)Only in connection with extra code 061;observe order detailsPage 6/10Data Sheet 401002DimensionsElectrical connectionPage 7/10Data Sheet 401002Process connectionØ8mm*Extra code 630 pressure channel Ø8mmPage 8/10Data Sheet 401002Connection diagramThe connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection, only use the installation instructions or the operating manual. The knowledge and the correct technical compliance with the safety information and warnings contained in these documents are mandatory for mounting, electrical connection, and startup as well as for safety during operation.Cable socketnection.Color coding: connecting cable round plug M12×11 BN Brown2 WH White3 BU Blue4 BKBlackThe color coding is only valid for A-coded standard cables!Page 9/10Data Sheet 401002Order details(1)Basic type401002/000JUMO MIDAS C08 – OEM pressure transmitter – basic401002/999JUMO MIDAS C08 – OEM pressure transmitter – basic, special version (2)Input4550to 1.6bar relative pressure 4560to 2.5bar relative pressure 4570to 4bar relative pressure 4580to 6bar relative pressure 4590to 10bar relative pressure 4600to 16bar relative pressure 4610to 25bar relative pressure 4620to 40bar relative pressure 4630to 60bar relative pressure 479-1to +0.6bar relative pressure 480-1to +1.5bar relative pressure 481-1to +3bar relative pressure 482-1to +5bar relative pressure 483-1to +9bar relative pressure 484-1to +15bar relative pressure 485-1to +24bar relative pressure999Special measuring range for relative pressure (3)Output4054to 20mA, two-wire4120. 5to 4.5V, three-wire, ratiometric 4150to 10V, three-wire 4181to 5V, three-wire 4201to 6V, three-wire (4)Process connection383Push-in fitting for pipe/hose 6×4DN 6502G 1/4 DIN EN 837504G 1/2 DIN EN 8375111/4-18 NPT DIN EN 837521G 1/4 DIN 547Rp 1/8 inside 5627/16-20 UNF(5)Process connection material 20CrNi (stainless steel)(6)Material seal 600EPDM 601FKM a 602CR 604FFKM 609NBR999Special materialPage 10/10Data Sheet 401002Accessories(7)Electrical connection 11Attached cable b 23Quickon36Round plug M12×153Bayonet connector DIN 7258561Cable socket DIN EN 175301-803, Form A (8)Extra codes 000None 061UL approval c591Choke in the pressure channel 624Oil and grease free 630Enlarged pressure channel d 876Test reporta Standardb The standard cable length is 2m. Further lengths are available upon request.c The UL approval stipulates use of the pressure transmitter indoors. In addition, process connection 383 as well as seals 609 and 999 are not possible. Special measuring ranges (input) are not allowed to exceed the 60 bar limit.dAn enlarged pressure channel of diameter Ø8mm is only available with process connection 1/4-18 NPT (process connection 511), G 1/4 (pro-cess connection 521) and the seal FKM (seal material 601).(1)(2)(3)(4)(5)(6)(7)(8)Order code ------/ , ...aOrder example401002/000-460-412-504-20-600-36/591aList extra codes in sequence, separated by commas.Minimum order volume for manufacturing devices: 5 pieces Minimum order volume for warehouse devices:1 pieceItemDescriptionPart no.Cable box, straightThe PVC connecting cable is 2m in length and has a 4-pin, straight M12×1 connector with gold-plated contacts on the device side.00404585Cable box, angledThe PVC connecting cable is 2m in length and has a 4-pin, angled M12×1 connector with gold-plated contacts on the device side.00409334。
FESTO SPAW压力传感器说明书

Pressure sensors SPAW with display2d Internet: /catalogue/...Subject to change – 2022/10Pressure sensors SPAW with displayKey featuresAt a glance[1] 9 pressure ranges from–1 … +1 bar to 0 … +100 bar [2] Protection class IP67[3] 320° rotatable display[4] 1% accuracy, 0.15% repetitionaccuracy[5] Temperature of medium–20 … 85°C [6] Materials in contact with media:CrNiMo: 316L, from a measuring range of 10 bar the membrane consists of 13-8-PH[7] 4-digit LED display, easy to read,robust [8] Display– bar – MPa – kPa – psi – kgf/cm²[9] Simple operation, protected byPIN code[10] 320° rotatable housing [11] Electrical connection M12[12] G1/4 female thread or G1/2 malethreadProduct descriptionMain applicationsThe SPAW is an extremely robust pressure sensor with display used for measuring media pressures in 9 measuring ranges from as small as –1 ... 1 bar up to 0 ... 100 bar. It can measure all media which do not react aggressively with the stainless steel measuring cell and stainless steel housing. The switching outputs can be set quickly and easily using three but-tons. The high-quality 14-segment LED display can be rotated 320° and theorientation of the text can be rotated 180°. This ensures that the display is easily readable in every installation position. Different standard designs are available, e.g.:• G1/4 female thread or G1/2 male thread• 2 x PNP or 2 x NPN • 4 ... 20 mA or 0 ... 10 VThe pressure sensor SPAW is suitable for standard pressure measurement at an increased mechanical load. It canbe used in high pressure pneumatic systems and to monitor the pressure of liquid media (e.g. coolant/cooling circuits, etc.)Pressure sensors SPAW with display Key features3 2022/10 – Subject to change d Internet: /catalogue/...Pressure sensors SPAW with displayPeripherals overview4d Internet: /catalogue/...Subject to change – 2022/10Pressure sensors SPAW with displayType codes52022/10 – Subject to change d Internet: /catalogue/...6d Internet: /catalogue/...Subject to change – 2022/10Pressure sensors SPAW with displayData sheetFunctione.g. switching output 2PVe.g. switching output 2NA• Pressure measuring range up to 100 bar• For liquid media •For gaseous media1)For information about the area of use, see the EC declaration of conformity at: /catalogue/SPAW d Support/Downloads.If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.2)Note media resistance of parts that come into contact with the mediaPressure sensors SPAW with display Data sheet7 2022/10 – Subject to change d Internet: /catalogue/...Pressure sensors SPAW with displayData sheet1)CrNiMo group: Measuring range up to 6 bar 316L, from a measuring range of 10 bar the membrane consists of 13-8-PH2)Corrosion resistance class CRC 4 to Festo standard FN 940070Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, e.g. in the chemical or food industries. Such applications may need to be safeguarded by means of special testing (d also FN 940082), using appropriate media.8d Internet: /catalogue/...Subject to change – 2022/10Pressure sensors SPAW with display Data sheet9 2022/10 – Subject to change d Internet: /catalogue/...Pressure sensors SPAW with displayData sheet10d Internet: /catalogue/...Subject to change – 2022/10Pressure sensors SPAW with display Data sheet11 2022/10 – Subject to change d Internet: /catalogue/...Pressure sensors SPAW with displayAccessories1)Temperature-dependent operating pressure –0.95 ... 14 bar12d Internet: /catalogue/...Subject to change – 2022/10。
BD SENSORS GmbH DMP 331 工业压力传感器说明书

BD SENSORS GmbH BD-Sensors-Straße 1 Tel.: +49 (0) 92 35 / 98 11- 0www.bdsensors.de D - 95199 ThiersteinFax: +49 (0) 92 35 / 98 11- 11*****************DMP 331IndustrialPressure Transmitter for Low PressureStainless Steel Sensoraccuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSONominal pressurefrom 0 ... 100 mbar up to 0 ... 60 b Output signals 2-wire: 4 ... 20 mA3-wire: 0 … 20 mA / 0 … 10 V others on request Special characteristic►perfect thermal behaviour ►excellent long term stability ►pressure portG 1/2" flush from 100 mbarOptional versions►IS-versionEx ia = intrinsically safefor gases and dusts ►SIL 2-according toIEC 61508 / IEC 61511►welded pressure sensor ►customer specific versionsThe pressure transmitter DMP 331 can be used in all industrial areas when the medium is compatible with stainless steel 1.4404 (316 L) or 1.4435 (316 L). Additional are different elastomer seals as well as a helium tested welded version available.The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions.Thus a diversity of variations is created, meeting almost all requirements in industrial applications. Preferred areas of use arePlant and machine engineeringEnvironmental engineering (water - sewage - recycling) Energy industrypressure and levelwww.bdsensors.deExplosion protection (only for 4 … 20 mA / 2-wire)ApprovalsDX19-DMP 331 IBExU 10 ATEX 1068 X / IECEx IBE 12.0027X zone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T135 °C DaSafety technical maximum values U i = 28 V, I i = 93 mA, P i = 660 mW, C i ≈ 0 nF, L i ≈ 0 μH,the supply connections have an inner capacity of max. 27 nF to the housingPermissible temperatures for environment in zone 0: -20 ... 60 °C with p atm 0.8 bar up to 1.1 bar in zone 1 or higher: -40/-20 ... 70 °CConnecting cables (by factory)cable capacitance: signal line/shield also signal line/signal line: 160 pF/m cable inductance: signal line/shield also signal line/signal line: 1 μH/mMiscellaneousOption SIL2 version 3 according to IEC 61508 / IEC 61511 Current consumption signal output current: max. 25 mAsignal output voltage: max. 7 mAWeight approx. 200 g Installation position any 4 Operational life 100 million load cycles CE-conformity EMC Directive: 2014/30/EU ATEX Directive 2014/34/EU3 only for4 … 20 mA / 2-wire, not in combination with accuracy 0.1 %4Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges p N ≤ 1 bar.Wiring diagrams2-wire-system (current)3-wire-system (current / voltage)Pin configuration Electrical connectionISO 4400Binder 723 (5-pin)M12x1 / metal(4-pin)Bayonet MIL-C-26482(10-6)2-wire3-wire Supply + Supply –Signal + (for 3-wire)1 2 33 4 1 1 2 3 A B -A D BShieldground pin54pressure portElectrical connectioncompact field housingcable colours (IEC 60757)V S+ V S- S+ GNDSupply + Supply –Signal + (for 3-wire)V S + V S - S+ WH (white) BN (brown) GN (green) ShieldGNDGNYE (green-yellow)psupply +supply –V SIsupply +A/Vsignal +V SpI/Usupply –ISO 4400 Binder series 723, 5-pin M12x1, 4-pin(IP 65) (IP 67) (IP 67)cable outlet with PVC cable cable outlet, cable with(IP 67) 5ventilation tube (IP 68) 6compact field housing(IP 67)universal field housing stainless steel 1.4404 (316 L) with cable gland M20x1.5 (ordering code 880) and other versions on request pressure and levelwww.bdsensors.deDimensions (mm / in)standardSIL- and SIL-IS version* with electrical connection Bayonet MIL-C-26482 (10-6) increases the length of devices by 5 mmMechanical connections (dimensions mm / in)G1/2" DIN 3852 G1/2" EN 837 1/2" NPTG1/4" DIN 3852 G1/4" EN 837 1/4" NPTG1/2" open port DIN 3852G1/2" flush DIN 3852(p N ≤ 40 bar) (p N ≤ 40 bar)DMP331_E_310123Tel.: +49 (0) 92 35 / 98 11- 0www.bdsensors.de Fax: +49 (0) 92 35 / 98 11- 11*****************© 2023 B D |S E N S O R S G m b H – T h e s p e c i f i c a t i o n s g i v e n i n t h i s d o c u m e n t r e p r e s e n t t h e s t a t e o f e n g i n e e r i n g a t t h e t i m e o f p u b l i s h i n g . W e r e s e r v e t h e r i g h t t o m a k e m o d i f i c a t i o n s t o t h e s p e c i f i c a t i o n s a n d m a t e r i a l s .metric threads and other versions on request**-------1101110.1010000.1616000.2525000.4040000.6060001.010011.616012.525014.040016.06001101002161602252502404002606002-1 … 0X 1029999consult123E 1S 9consultstandard for p N ≥ 0.4 bar:0.35 % FSO 3standard for p N < 0.4 bar:0.50 % FSO 5option 1 for p N ≥ 0.4 bar:0.25 % FSO 2option 2:0.10 % FSO19consult100200T A 0cable with ventilation tube (IP68)M 10B G 0B G 4stainless steel 1.4301 (304)999consult 10020030040055H 00N 00N 40999consult1329consult000999consult1 absolute pressure possible from 0.4 bar2 not in combination with SIL3 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70°C), others on request4code TR0 = PVC cable, cable with ventilation tube available in different types and lengths 5only for p N ≤ 40 bar6welded version only with pressure ports according to EN 837 and NPT31.01.2023customer34T R 0111intrinsic safety 4 … 20 mA / 2-wire2gauge 4 … 20 mA / 2-wire SIL2 4 … 20 mA / 2-wire 0 … 10 V / 3-wire0 … 20 mA / 3-wire absolute customer15, 6without (welded version)© 2023 B D |S E N S O R S G m b H - T h e s p e c i f i c a t i o n s g i v e n i n t h i s d o c u m e n t r e p r e s e n t t h e s t a t e o f e n g i n e e r i n g a t t h e t i m e o f p u b l i s h i n g . W e r e s e r v e t h e r i g h t t o m a k e m o d i f i c a t i o n s t o t h e s p e c i f i c a t i o n s a n d m a t e r i a l s .DMP 331standard G1/4" DIN 3852customercustomerEPDM4 … 20 mA / 2-wirecustomercustomerSIL2 with intrinsic safetymale plug M12x1 (4-pin) / metal ES G1/4" EN 837G1/2" DIN 3852male and female plug ISO 4400male plug Binder series 723 (5-pin)cable outlet with PVC cable (IP67)8customercable outlet,1/4" NPT FKM Bayonet MIL-C-26482 (10-6); 2 wire Bayonet MIL-C-26482 (10-6); 3 wire00F G1/2" EN 837G1/2" DIN 3852501/2" NPT compact field housing G1/2" DIN 3852 open pressure portwith flush sensor。
B-38BMILLIVOLT 压力传感器产品说明书

0 to 1000 0 to 68.9 PX6[*]2-1KGV D P41-S, DP25B-S, DP302-S
0 to 2000 0 to 138
PX6[*]2-2KGV D P41-S, DP25B-S, DP302-S
0 to 3000 0 to 207
PX6[*]2-3KGV D P41-S, DP25B-S, DP87
PT06F8-4S mating connector,
sold separately.
MILLIVOLT OUTPUT PRESSURE TRANSDUCERS
SQUARE
U All Stainless Steel Case
P-DPG500 Fig. 1
Actual size.
PX602-1KGV, cable style.
20.32
Pin Wire
(0.8)
A Red +Exc
B Green +Out
C Black -Out
D White -Exc
Hysteresis: ±0.2% Repeatability: ±0.05%
To Order
Stability: ±1%/year
Zero Balance: ±1%
Durability: 100 million cycles
Operating Temp: -48 to 91°C (-55 to 195°F)
Compensated Temp: -29 to 82°C (-20 to 180°F)
Thermal Zero Effect: ±0.07% full scale/°C
Thermal Span Effect: ±0.07% full scale/°C
FESTO SPAE 电子压力传感器说明书

Pressure sensors SPAE2d Internet: /catalogue/...Subject to change – 2023/08Pressure sensors SPAEKey featuresAt a glance• Single-button operation • 7-segment display• Switching status indication• Various pneumatic connection options• Choice of pressure rangesFunctionThe SPAE is an electronic pressure sensor with piezoresistive pressure measuring cell, integrated signal processing, pressure indicator with percentage, control button and a switching output, PNP/NPN switchable. Two switching signals and the measured value can be transmitted via IO-Link.• The sensor can be set using the key and display oralternatively using IO-Link or teach-in• Switching functions: threshold value or window comparator• Switching logic: normally open (NO) or normally closed (NC)• Threshold values and hysteresis are adjustable• Display of minimum and maximum measured values• Display can be rotated and switched off• Protection against tampering using security code• All parameters that have been input can be transferred to other SPAE(replicator function)H- -NoteThe version with 10 mm cartridge is designed for the vacuum generator OVEL.Pressure sensors SPAE Peripherals overview3 2023/08 – Subject to change d Internet: /catalogue/...4d Internet: /catalogue/...Subject to change – 2023/08Pressure sensors SPAEType codesH- -NotePressure measuring range: Additional pressureranges on request (batch size 40)52023/08 – Subject to changed Internet: /catalogue/...Pressure sensors SPAEData sheetFunction-P- Voltage 18 ... 30 V DC-L- Pressure measuring range –1 ... +10 bar -Q-Temperature range0 ... +50°C1)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.2)For information about the area of use, see the EC declaration of conformity at: /catalogue/... d Support/Downloads.If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.Pressure sensors SPAEData sheet6d Internet: /catalogue/...Subject to change – 2023/08Pressure sensors SPAE Data sheet7 2023/08 – Subject to change d Internet: /catalogue/...Pressure sensors SPAEData sheet8d Internet: /catalogue/...Subject to change – 2023/08Pressure sensors SPAE Data sheet1)Additional pressure ranges on request (batch size 40)9 2023/08 – Subject to change d Internet: /catalogue/...Pressure sensors SPAE Accessories Mounting clip SAMH-PE-MC-1Material:POMNote on materials:RoHS-compliantMounting clip SAMH-PE-MC-8Material:POMNote on materials:RoHS-compliantH--NoteThe mounting clip SAMH-PE-MC-8 can be shortened by the user to the requirednumber of slots.10d Internet: /catalogue/...Subject to change – 2023/08Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。
压力传感器一览表说明书

No.PS※※-OMG0006-DPressure Sensor for General FluidsPSE56#Safety Instructions 2 Model Identification and How to Order 8 Definition and terminology 8 Mounting and Installation 9 Wiring 9 Troubleshooting 11 Specification 12 Specifications 12 Dimensions 14Safety InstructionsThese safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations.*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.ISO 4413: Hydraulic fluid power -- General rules relating to systems.IEC 60204-1: Safety of machinery -- Electrical equipment of machines. (Part 1: General requirements)ISO 10218: Manipulating industrial robots -Safety.etc.Caution Caution indicates a hazard with a low level of risk which, if not avoided, couldresult in minor or moderate injury.Warning Warning indicates a hazard with a medium level of risk which, if not avoided,could result in death or serious injury.Danger Danger indicates a hazard with a high level of risk which, if not avoided, willresult in death or serious injury.Warning1. The compatibility of the product is the responsibility of the person who designs theequipment or decides its specifications.Since the product specified here is used under various operating conditions, its compatibility withspecific equipment must be decided by the person who designs the equipment or decides itsspecifications based on necessary analysis and test results.The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product.This person should also continuously review all specifications of the product referring to its latestcatalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.2. Only personnel with appropriate training should operate machinery and equipment.The product specified here may become unsafe if handled incorrectly.The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.3. Do not service or attempt to remove product and machinery/equipment until safety isconfirmed.1. The inspection and maintenance of machinery/equipment should only be performed after measuresto prevent falling or runaway of the driven objects have been confirmed.2. When the product is to be removed, confirm that the safety measures as mentioned above areimplemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.4. Contact SMC beforehand and take special consideration of safety measures if theproduct is to be used in any of the following conditions.1. Conditions and environments outside of the given specifications, or use outdoors or in a placeexposed to direct sunlight.2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.3. An application which could have negative effects on people, property, or animals requiring specialsafety analysis.4. Use in an interlock circuit, which requires the provision of double interlock for possible failure byusing a mechanical protective function, and periodical checks to confirm proper operation.Safety InstructionsCaution1.The product is provided for use in manufacturing industries.The product herein described is basically provided for peaceful use in manufacturing industries.If considering using the product in other industries, consult SMC beforehand and exchangespecifications or a contract if necessary.If anything is unclear, contact your nearest sales branch.Limited warranty and Disclaimer/Compliance RequirementsThe product used is subject to the following "Limited warranty and Disclaimer" and "Compliance Requirements".Read and accept them before using the product.Limited warranty and Disclaimer1. The warranty period of the product is 1 year in service or 1.5 years after the product isdelivered, whichever is first.*2)Also, the product may have specified durability, running distance or replacement parts.Please consult your nearest sales branch.2. For any failure or damage reported within the warranty period which is clearly ourresponsibility, a replacement product or necessary parts will be provided.This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.3. Prior to using SMC products, please read and understand the warranty terms anddisclaimers noted in the specified catalog for the particular products.*2) Vacuum pads are excluded from this 1 year warranty.A vacuum pad is a consumable part, so it is warranted for a year after it isdelivered.Also, even within the warranty period, the wear of a product due to the use of thevacuum pad or failure due to the deterioration of rubber material are not coveredby the limited warranty.Compliance Requirements1. The use of SMC products with production equipment for the manufacture of weaponsof mass destruction (WMD) or any other weapon is strictly prohibited.2. The exports of SMC products or technology from one country to another are governedby the relevant security laws and regulation of the countries involved in thetransaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.CautionSMC products are not intended for use as instruments for legal metrology.Products that SMC manufactures or sells are not measurement instruments that are qualified by pattern approval tests relating to the measurement laws of each country.Therefore, SMC products cannot be used for business or certification ordained by the measurement laws of each country.Caution■After maintenance is complete, perform appropriate functional inspections and leak tests.Stop operation if the equipment does not function properly or there is a leakage of fluid.When leakage occurs from parts other than the piping, the product might be faulty.Disconnect the power supply and stop the fluid supply.Do not apply fluid under leaking conditions.Safety cannot be assured in the case of unexpected malfunction.■NOTE○Follow the instructions given below when designing, selecting and handling the product.●The instructions on design and selection (installation, wiring, environment, adjustment,operation, maintenance, etc.) described below must also be followed.*Product specifications∙The direct current power supply to combine should be UL approved as follows.Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer.∙The Pressure Sensor is a UL approved product only if it has a mark on the body.∙Use the specified voltage.Otherwise failure or malfunction can result.∙Use the specified measurement flow rate and operating pressure.Otherwise it can cause damage to the Pressure Sensor or inability to measure correctly.∙Applicable fluid is a fluid that does not corrode SUS316L.Do not use a fluid containing chemicals, synthetic oils including organic solvent, salt and corrosive gases.Otherwise, damage to the product and malfunction can result.Check the details of the specifications before using.∙Reserve a space for maintenance.Allow sufficient space for maintenance when designing the system.∙A pressure sensor of stainless steel diaphragm is used for this product. The pressure sensor can be damaged by the rush inertia of water when the drain contained in water and air collide with thepressure sensor when vacuum is broken after vacuum adsorption is confirmed, and it may causemalfunction with the pressure indication.In the above case, make an orifice in the Location shown in the Fig. below or mount the external adapter with throttle (ZS-31-X175, X186, X188 or X189) to the fitting.Pipe an orifice vertically and so that no water (solution) remains between the product and orifice.●Product handling*Installation∙Follow the specified tightening torque.Excessive tightening torque can break the Pressure Sensor.Insufficient tightening torque can displace the Pressure Sensor from the original position or loosen the mounting∙When piping, apply a spanner vertically to the piping section for the sensor.Applying the wrench in other position can break the Pressure Sensor∙Keeping from water dust, set an air tube to the safety area.∙fittings) for TSJ fittings, packing andfittings) for URJ fittings.Otherwise safety may not be secured due to leakage from joint. When using ferules, packing or glands made by other manufacture, be sure to perform helium test to verify no leakage.∙Be sure to ground terminal FG when using a commercially available switch-mode power supply.∙Do not drop, hit or apply shock to the Pressure Sensor.Otherwise damage to the internal parts can result, causing malfunction.∙Do not pull the lead wire forcefully, not lift the product by pulling the lead wire. (Tensile force 35N or less) Hold the body when handling to avoid the damage of the Pressure Sensor lead to cause the failure andmalfunction.∙For piping of the Pressure Sensor, hold the piping with a spanner on the metal part of the piping (Piping attachment).Holding other part with spanner leads to damage the Pressure Sensor.∙Eliminate any dust left in the piping by air blow before connecting the piping to the product.Otherwise it can cause damage or malfunction.∙Do not insert metal wires or other foreign matter into the pressure measurement port.It can damage the Pressure Sensor causing failure or malfunction.*Wiring∙Do not pull the lead wires.In particular, never lift a Pressure Sensor equipped with fitting and piping by holding the lead wires.∙Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them.Repetitive bending stress or tensile stress can cause the sheath of the wire to peel off, or breakage of the wire.If the lead wire can move, fix it near the body of the product.The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger.Replace the damaged lead wire with a new one.∙Wire correctly.Incorrect wiring can break the Pressure Sensor.∙Do not perform wiring while the power is on.Otherwise damage to the internal parts can result, causing malfunction.∙Do not route wires and cables together with power or high voltage cables.Otherwise the product can malfunction due to interference of noise and surge voltage from power and high voltage cables to the signal line. Route the wires (piping) of the product separately from power or high voltage cables.∙Confirm proper insulation of wiring.Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess voltage or current being applied to the product, causing damage.∙Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage.Do not use a cable longer than 30 m.Wire the DC(-) line(blue) as close as possible to the power supply.∙When analogue output is used, install a noise filter (line noise filter, ferrite element, etc.) between the switch-mode power supply and this product.*Environment∙Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam.Otherwise failure or malfunction can result.∙Do not use in a place where the product could be splashed by oil or chemicals.If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires).∙Do not use in an area where surges are generated.If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the Pressure Sensor, this may cause deterioration or breakage of the internal circuit of the Pressure Sensor. Avoid sources of surge generation and crossed lines.∙The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system.∙Mount the product in a place that is not exposed to vibration or impact.Otherwise failure or malfunction can result.∙Prevent foreign matter such as remnant of wires from entering the Pressure Sensor.Take proper measures for the remnant not to enter the Pressure Sensor in order to prevent failure or malfunction. ∙Do not use the product in an environment that is exposed to temperature cycle.Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product.∙Do not expose the product to direct sunlight.If using in a location directly exposed to sunlight, shade the product from the sunlight.Otherwise failure or malfunction can result.∙Keep within the specified fluid and ambient temperatures range.The fluid and ambient temperatures should be -10 to 60 °C. Operation under low temperature leads to cause damage or operation failure due to frozen moist in the fluid or air.Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water.Avoid sudden temperature change even within specified temperature.∙Do not operate close to a heat source, or in a location exposed to radiant heat.Otherwise malfunction can result.*Adjustment and Operation∙Do not short-circuit the load.∙If using the product to detect very small pressure rates, warm up the product for 20 to 30 minutes first.There will be a drift on the analogue output of approximate ±1% immediately after the power supply is turned on, within 10 minutes.*Maintenance∙Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance.There is a risk of unexpected malfunction.∙Perform regular maintenance and inspections.There is a risk of unexpected malfunction.∙Perform drainage regularly.If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.∙Do not use solvents such as benzene, thinner etc. to clean the Pressure Sensor.They could damage the surface of the body and erase the markings on the body.Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth.■Wiring○Attaching the connector to the lead wire∙Sensor wire is stripped as shown in the right figure. ∙Do not cut the insulation.∙The core of the corresponding color shown in thefollowing table is put into the pin of the number stamped∙It checks that the above-mentioned preparation work has been performed correctly, and A part shown in right figure is pushed by hand and makes temporary connection. ∙A part center is straightly pushed in by tools, such as pliers.∙Re-use cannot be performed once it connects the connector for sensor connection completely. When you fail in the connection mistake of a core and a pin, or the plug of wire, please use the new connector for sensor connection.catalogue.○Connector and applicable pressure sensorConnecting/Disconnecting∙When connecting the connector, insert it straight onto the pin holding the lever and connector bodybetween fingers and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks.∙When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the square groove. Then pull the connector straight out.PSE200 seriesPSE300 series○Internal circuit and wiring example∙Output specificationPSE56□-□Voltage output: 1 to 5 VOutput impedance: Approx. 1 kΩPSE56□-□-28Current output: 4 to 20 mAAllowable load impedance:500 Ω or less (at 24 VDC)100 Ω or less (at 12 VDC) *: Install the load either on the LINE(+) or LINE(-) side.○Cross-reference for troubleshooting○Analogue outputRange Rated pressure range A B C For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPaFor compound -100 to 100 kPa -100 kPa 100 kPa -For positive pressure0 to 1 MPa 0 1 MPa -0.1 MPa 0 to 500 kPa 0 500 kPa -50 kPa■Dimensions∙PSE56□- 01 , PSE56□- N0102 N02Be sure to release the air in the air tube of the cable to the atmosphere.If the air tube is restricted, or left in an environment where it is exposed to water or oil, it cannot be detected normally.∙PSE56□-C01Model No. A B PSE56□-01 8.2 R1/8 PSE56□-02 12 R1/4 PSE56□-N01 9.2 NPT1/8 PSE56□-N02 12.2 NPT1/4 PSE56□-C01 - Rc1/8 PSE56□-A2 15.5 URJ1/4 PSE56□-B29.5TSJ1/4∙PSE56□-A2∙PSE56□-B2∙Adapter with throttle ZS-31-X □□□Model No. D E F G H I ZS-31-X188 20 9 R1/8 R1/8 14 1.5 ZS-31-X189 20 9 NPT1/8 NPT1/8 14 1.5 ZS-31-X175 29 13 R1/4 R1/4 17 1.6 ZS-31-X186 29 13 NPT1/4 NPT1/4 17 1.64-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPANTel: + 81 3 5207 8249 Fax: +81 3 5298 5362URL Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.。
Festo SPAU 2 压力传感器说明书

Pressure sensors SPAUPressure sensors SPAU CharacteristicsAt a glanceProduct descriptionThe pressure sensor SPAU is suitable for monitoring compressed air and non- corrosive gases. The variant with display offers the option of reading the pressure and set values on-site. The pressure value is transmitted to the connected control system as a switching signal, as an analogue signal or via IO-Link.The pressure sensor without display transmits the pressure value to the connect-ed control system as an analogue signal. Display of the pressure and parameteri-sation of the sensor are provided centrally, e.g. via a display that is part of a ma-chine control system. The pressure sensor can be parameterised using IO-Link asa tamper-proof pressure switch without display with up to two switching outputs.Areas of application• Network monitoring (pressure present)• Regulator monitoring (pressure in the setpoint range)• Vacuum (part picked up)• Leak test (pressure drop over time)• Object detection (back pressure present)Product benefitsA mounting concept that is quick tomount and that is easy to implement inall installation situations. Female/malethread or push-in fitting QS – theperfect pneumatic adapter for everyapplication.Mounting:• Threaded mounting• H-rail mounting• Front panel mounting• Mounting bracket• Wall mounting• Adapter to MS4, MS6Electronics:• Maximum versatility and reducedwarehousing thanks to switchableelectrical outputs (PNP/NPN/N/Ccontact/N/O contact and current/voltage output)2d Internet: /catalogue/...Subject to change – 2022/01Pressure sensors SPAU CharacteristicsOperationMonitoring and setting of a pressurethreshold, a pressure range or apressure difference, using a teach-infunction or by entering values.Variants with display:• Pressure indicator, pressure switch-ing outputs and analogue value out-put from a device can be set on-site • Quick commissioning of the pres-sure sensor thanks to straightfor-ward menu navigation• Display colour blue/red as visual feedback about the pressure of the medium • Min./max. value memory for moni-toring compressed air (display ofrapid pressure peaks that are notvisible to the human eye)• Adjustable filter evens out the sen-sor signal generated by pressurepeaks• Scaling the analogue output toincrease the signal dynamics• Choice of pressure units: bar, MPa,PSI and more• Offset compensation possible• ECO function "Switch off display"available• Optional security code can be freelychosen (4-digit code)• All the settings for one sensor (mas-ter) can be transferred (replication)to other, identical sensors (device).This significantly shortens thecommissioning timeVariants without display:• Analogue value output and pressure switching outputs proportional to the pressure • Switching output behaviour can beset on the machine display usingIO-Link• Other functions can be set usingIO-LinkVariants with IO-Link:• With and without display• Serial communication integrated using IO-Link 1.1• Analogue process value is provided digitally • The sensor can be parameterisedand maintained remotely at controllevel using an IO-Link master• Automatic parameterisation follow-ing a sensor change means there isno need to re-parameterise or enterthe settings again after changingthe sensor32022/01 – Subject to change d Internet: /catalogue/...Pressure sensors SPAU CharacteristicsThe connections shown are by way of example.Variants with display and MS adapter4d Internet: /catalogue/...Subject to change – 2022/01Pressure sensors SPAU CharacteristicsDevice variantsVariants without displayThe connections shown are by way of example.5 2022/01 – Subject to change d Internet: /catalogue/...Pressure sensors SPAUCharacteristics1)Threaded mounting with M5 female thread not recommended6d Internet: /catalogue/...Subject to change – 2022/01Pressure sensors SPAU Peripherals overview117 2022/01 – Subject to change d Internet: /catalogue/...Pressure sensors SPAUType codes8d Internet: /catalogue/...Subject to change – 2022/0192022/01 – Subject to changed Internet: /catalogue/...Pressure sensors SPAUData sheetDisplay … -LVariant without display Voltage output preset… -LK-VVariant without display Current output preset… -LK-A-P- Voltage 20 ... 30 V DC-L-Pressure measuring range –1 ... +16 bar -Q-Temperature range0 ... +50°CPressure sensors SPAUData sheet1)Second PNP output can only be activated using IO-Link1)0 ... 10 V analogue output can only be activated using IO-Link2) 1 ... 5 V analogue output can only be activated using IO-Link3) 4 ... 20 mA analogue output can only be activated using IO-Link10d Internet: /catalogue/...Subject to change – 2022/011)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.[1]M5Only with type of mounting A, F.[2]Q4, Q6, T532Not with type of mounting T.Not with pressure measuring range P16.[3]M, F Mandatory information in combination with pneumatic connection G18, N18, R18, R14, M7, M5.[4]M Not with type of mounting H, W, MS4, MS6.Not with pneumatic connection Q4, Q6, T532, M7, M5.[5]F Not with type of mounting A if pneumatic connection G18, R18, N18.Not with type of mounting MS4, MS6.Not with pneumatic connection Q4, Q6, Q532.[6]Not with type of mounting W, H.Not with thread type F if pneumatic connection G18, R18, N18.[7]D Not with pneumatic connection M5.Not with type of mounting A, MS4, MS6.Not with thread type M.[8]L Mandatory information in combination with type of mounting F, MS4, MS6.[9]LK, V, B, A Not with display L.[10]PNLK, PNVBA Not without display.[11]Only with type of mounting A, F.Not with pneumatic connection G18, N18, R18, M7, M5.Not with outlet orientation D, U.Only with thread type "without".[12]D Mandatory information in combination with type of mounting MS4, MS6.Only with outlet orientation D if pneumatic connection Q4 or T532 selected.Not with outlet at rear if pneumatic connection Q4, Q6, T532.[13]U Only with outlet orientation U if pneumatic connection Q4 or T532 selected.Not with outlet at rear if pneumatic connection Q4, Q6, T532.[15]R14Only with thread type M.Outlet at rear only.Not with type of mounting W, H.Not with electrical outlet at rear.[16]G Only with display L.[17]F Only with type of mounting MS4, MS6.Accessories Mounting bracket SAMH-PU-AType of mounting: via through-hole and screwMaterial:High-alloy stainless steelNote on materials: RoHS-compliant Only for variants with: pneumaticconnection with outlet at rear1) Corrosion resistance class 2 to Festo standard 940 070Components subject to moderate corrosion stress. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or lubricating agents. Wall mounting SAMH-PU-WType of mounting: via through-hole Material:High-alloy stainless steelNote on materials: RoHS-compliant Only for variants with: pneumaticconnection with outlet underneath1)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.Pressure sensors SPAU Accessories – Ordering dataSafety guard SACC-PU-Gto protect the display and controlelements Material: PA Note on materials: RoHS-compliantOnly for variants with: display1)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation can occur. External visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment.21 2022/01 – Subject to change d Internet: /catalogue/...Pressure sensors SPAUAccessories22d Internet: /catalogue/...Subject to change – 2022/01Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。
Festo SPAB-P10R-G18-2P-K1 压力传感器说明书

Protection against manipulation Threshold value setting range Hysteresis setting range Protection class Corrosion resistance classification CRC
01/07/2017 – Subject to change – Festo AG & Co. KG
Value
RCM Mark c UL us - Recognized (OL) to EU directive for EMC Contains PWIS substances Conforms to RoHS Relative pressure Piezoresistive pressure sensor with display 0 bar 10 bar 15 bar Compressed air in accordance with ISO8573-1:2010 [7:4:4] Lubricated operation not possible -10 ... 50 °C 2xPNP Freely programmable Switchable 0.2 %FS 100 mA 2 %FS Yes 12 ... 24 V for all electrical connections Cable 4-core 2.5 m Optional Threaded with accessories Male thread G1/8 Female thread M5 45 g ABS-reinforced PBT-reinforced Illuminated LCD, multicoloured MPa bar kPa kgf/cm² psi LCD, yellow Teach-In Via display and buttons PIN-Code 0 ... 100 % 0 ... 90 % IP40 2 - Moderate corrosion stress
FESTO SDE3系列压力传感器说明书

Pressure sensors SDE3, with displaySubject to change – 2019/052è Internet: /catalog/...Pressure sensors SDE3Key features At a glanceSDE3-…-M…plug version,plug M8x1 and M12x1SDE3-…-FQ…,cable with plugPressure display:–Alphanumeric –Bar chartFast front panel mounting Fast H-rail, wall or surface mountingGreater ease of use –Easy teach-in–Intuitive user guidance via LCD displayHigh-contrast, two-colourLCD display Product descriptionMain applicationsKey featuresThe pressure sensor SDE3 is a slim,space-optimised pressure sensor.It can be used wherever information about the current pressure is required and the focus is on space-saving mounting combined with ease of use.Compressed air monitoring Regulator monitoringSuction confirmation in vacuum technology Leak testsObject detection via back pressure Differential pressure measurementFastest possible H-rail and front panel mounting in a small space Minimal assembly times thanks to QS connectionsIntuitive user guidance via LCD displayAlphanumeric and bar chart pressure display for dynamic processes Individual alphanumeric code lock for protection from manipulationEasy teach-inRelative pressure, differential pressure or two independent pressure inputsFive pressure measuring ranges:0 … –1, –1 … 1, 0 … 2, 0 … 6,0 … 10 barHigh-contrast, two-colour LCD displayElectrical outputs: 2 switching outputs PNP or NPNProduct range overviewMeasured variable Pressure measuringrange Switching function PneumaticconnectionElectricalconnectionType of mounting Electrical output[bar]Digital Analogue1x relative pressure,2x relative pressure,1x differential pressure 1x relative pressure and 1x differential pressure 0 … –1–1 … +10 (2)0 (6)0 (10)FreelyprogrammablePush-in connectorFor tubing O.D.∅ 4 mmFor tubing O.D.∅5/32Plug M8x1Plug M12x1CableVia H-rail,wall bracket,surface bracket,front panel mountingor through-hole2x PNP–2x NPN–2019/05 – Subject to change3è Internet: /catalog/...Subject to change – 2019/054è Internet: /catalog/...Peripherals overview3Accessories è Page/Internet 1Pressure sensor SDE3-…-K62Pressure sensor SDE3-…-M8/-M1263Pressure sensor SDE3-…-F…64Connecting cable NEBU, straight socket 135Connecting cable NEBU, angled socket13Accessories è Page/Internet 6Adapter plate SXE3-W(included in the scope of delivery with SDE3-…-W…)137Mounting rail to EN 60715nrh 8Clamping plate(included in the scope of delivery with SDE3-…-F…)–Type codesSDE3–D10S–B–HQ4–2P–M8TypeSDE3Piezoresistive pressure sensor with displayPressure measuring range [bar]V10 … –1B2–1 … +1D20 (2)D60 (6)D100 (10)Pressure inputS1x relative pressureD2x relative pressureM1x relative pressure, 1x differential pressureZ1x differential pressureDisplayB Values in barH Values in inches of mercuryMounting/pneumatic connectionHQ4Via H-rail, 4 mm push-in connectorWQ4Wall mounting, 4 mm push-in connectorFQ4Front panel mounting, 4 mm push-in connectorElectrical output2P 2 switching outputs PNP2N 2 switching outputs NPNElectrical connectionM8Plug M8x1M12Plug M12x1Additional variants can be ordered using the modular system è 12DisplayMounting/pneumatic connectionElectrical connectionEU CertificationElectrical accessoriesè Internet: /catalog/...2019/05 – Subject to change5Technical dataGeneral technical dataSDE3-V1-B2-D2-D6-D10GeneralCertification cULus recognized (OL)1)RCM trademarkCE marking (see declaration of conformity)To EU EMC DirectiveTo EU Explosion Protection Directive (ATEX)Note on materials Free of copper and PTFERoHS-compliantInput signal/measuring elementMeasured variable Relative pressure2x relative pressure1x relative pressure, 1x differential pressureDifferential pressureMethod of measurement Piezoresistive pressure sensor with displayOperating medium Compressed air in accordance with ISO 85731:2010 [7:4:4]Note on operating/pilot medium Operation with lubricated medium possible (in which case lubricated operation will always be required)Pressure measuring range[bar]0 ... –1–1 ... +10 ... 20 ... 60 (10)Temperature of medium[°C]0 (50)Ambient temperature[°C]0 (50)1)Not with variant F (front panel mounting)Electrical dataSDE3-2P-2NOutput, general1)Accuracy FS[%]2Switching outputSwitching output2x PNP2x NPNSwitching function Freely programmableSwitching element function SwitchableReproducibility of switching value[%]0.3Max. output current[mA]100Output, additional dataProtection against short circuit PulsedElectronic componentsOperating voltage range DC[V]15 (30)Reverse polarity protection For all electrical connectionsLinearity error ±FS1)[%]0.31)% FS = % of the measuring range final value (full scale)6è Internet: /catalog/...Subject to change – 2019/05Technical dataElectrical dataSDE3-2P-2N Electromechanical componentsElectrical connection Plug M8x1, 4-pin, round design to EN 60 947-5-2Plug M12x1, 5-pin, round design to EN 60 947-5-2Cable with plug M8x1, 4-pin, round design to EN 60 947-5-2Cable with plug M12x1, 5-pin, round design to EN 60 947-5-2Cable 2.5 m, 4-wire, to EN 60 947-5-2Mechanical componentsSDE3-H…-W…-F…Type of mounting Via H-railVia through-hole Via H-railVia through-holeVia wall/surface bracketFront panel mountingMounting position AnyPneumatic connection QS-4QS5/32Product weight[g]373761Adapter plate weight[g]–6–Cable length[m]––0.3Housing materials PA, reinforcedPCDisplay/operationDisplay type Illuminated LCDSwitching status display LCD yellowSetting options Teach-inTamper protection PIN codeThreshold value setting range[%]0 (100)Hysteresis setting range[%]0 (90)Immissions/emissionsProtection class IP65Corrosion resistance class CRC1)21)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.ATEXSDE3-…-EX2ATEX category for gas II 3GExplosion ignition protection type for gas Ex ec IIC T6 X GcATEX category for dust II 3DExplosion ignition protection type for dust Ex tc IIIC T80°C X DcExplosion-proof temperature rating0 °C ≤ Ta ≤ +50 °C2019/05 – Subject to change7è Internet: /catalog/...Technical dataType B1B2B3D1D2D3H1H2L1L2L3L4L5L6L7L8 SDE3-…-HQ4-M82014–QS4M8x1 3.4374651735.475.124.33033.2–SDE3-…-HQ4-M12M12x182.8SDE3-…-HT532-M82014–QS5/32M8x1 3.4374651735.475.124.33033.2–SDE3-…-HT532-M12M12x182.8SDE3-…-WQ4-M8201412QS4M8x1 3.4374651735.475.124.33033.29 SDE3-…-WQ4-M12M12x182.8SDE3-…-WT532-M8201412QS5/32M8x1 3.4374651735.475.124.33033.29 SDE3-…-WT532-M12M12x182.88è Internet: /catalog/...Subject to change – 2019/05Technical dataType B1B2B3B4D1D2H1H2L1L2L3L4L5L6SDE3-…-FQ4-M827.4143521.8QS-4M8x13257435.479.230069.865 SDE3-…-FQ4-M12M12x1SDE3-…-FT532-M827.4143521.8QS5/32M8x13257435.479.230069.865 SDE3-…-FT532-M12M12x1è Internet: /catalog/...2019/05 – Subject to change9Technical data1)Adapter plate SXE3-W included in the scope of delivery10è Internet: /catalog/...Subject to change – 2019/05Pressure sensors SDE3, with displayTechnical dataè Internet: /catalog/...2019/05 – Subject to change11Pressure sensors SDE3 Ordering data – Modular products Ordering tableConditions Code Entercode0M Module No.539679Function Pressure sensor SDE3SDE3Pressure measuring range [bar]0 … –1-V1–1 … 1-B20 … 2-D20 … 6-D60 … 10-D10Pressure input1x relative pressure S2x relative pressure, independent D1x relative pressure, 1x differential pressure M1x differential pressure Z Display Values in bar-BValues in psi-PValues in kPa-KValues in inches of mercury-HValues in inches of water1-W Mounting/pneumatic connection H-rail mounting, 4 mm push-in connector-HQ4H-rail mounting, 5/32 push-in connector-HT532Wall mounting, 4 mm push-in connector-WQ4Wall mounting, 5/32 push-in connector-WT532Front panel mounting, 4 mm push-in connector-FQ4Front panel mounting, 5/32 push-in connector-FT532 Electrical output 2 switching outputs PNP-2P2 switching outputs NPN-2NElectrical connection Plug M8-M8Plug M12, A-coded-M12Cable, 2.5 m-K0O EU certification II 3GD to EU Directive 2014/34/EU-EX2 Connecting cable (accessory)Connecting cable, straight socket, 2.5 m2-GConnecting cable, angled socket, 2.5 m2-WConnecting cable, straight socket, 5 m2-G5Connecting cable, angled socket, 5 m2-W51W Not with pressure measuring range D6 and pressure input M orpressure measuring range D10 and pressure input M.2G, W, G5; W5Not with electrical connection KTransfer order code539679SDE3––––––––Subject to change – 2019/05 12è Internet: /catalog/...2019/05 – Subject to change 13è Internet: /catalog/...Pressure sensors SDE3, with displayAccessoriesOrdering dataPart No.Type Adapter plate 1)540214SXE3-W1)Included in the scope of delivery with SDE3-…-W…Number of wires44Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。
Festo Kernprogramm SDE5 压力传感器说明书

Drucksensoren SDE5e Festo KernprogrammLöst 80 % Ihrer Automatisierungsaufgaben Das Festo Kernprogramm ist eine Vorauswahl der wichtigsten Funktionen und Produkte – Teil unseres gesamten Produktportfolios.Weltweit: Gewohnt gut: Schnell zum Ziel:Schnell verfügbar, auch langfristigImmer in Festo QualitätEinfache AuswahlIm Kernprogramm fi nden Sie dasbeste Preis-Leistungs-Verhältnis fürIhre Automatisierung.Schauen Sienach demStern!2d I nternet: /catalogue/...Änderungen vorbehalten – 2023/02Drucksensoren SDE5MerkmaleAuf einen Blick SDE5-…-M8,Steckerausführung,Stecker M8x1, 3-poligSDE5-…-K,Kabelausführung,2,5 m lang, 3-adrigVerkettbarer Wandhalter zum Einklipsen des Sensors (im Lieferumfang enthalten)ProduktbeschreibungHauptanwendungenMerkmaleDer Drucksensor SDE5 ist die preisgünstige Alternative für ein-fache und schnelle Drucküber-wachungen.Das “intelligente Fitting” liefert sofort Informationen über dena ktuell anliegenden Druck und überzeugt in der Druckluft-,R egler- und Vakuumerfassung ebenso wie bei der Objekter-fassung via Staudruck.Der Drucksensor SDE5 kann über-all dort eingesetzt werden, wo einfache Abfragen über den anlie-genden Druck erforderlich ist:• Druckluftüberwachung • Reglerüberwachung• Ansaugbestätigung in derV akuumtechnik • Objekterfassung überS taudruck • Wählbare Ausgangsfunktionen• Programmierung durch Teach-Verfahren• Kürzeste Montagezeiten durch QS-Anschlüsse und verkett-baren Wandhalter• Schnellste Schaltpunkteinstel-lung per einfachem Knopfdruck • Schaltzustandsanzeige durch rundum sichtbare LED• Relativdruck- oder Differenz-druckmessung• 5 Druckmessbereiche: 0 ... –1, –1 ... 1, 0 ... 2, 0 ... 6, 0 ... 10 bar• Analogausgang: 0 ... 10 V• Elektrische Ausgänge: 1 Schalt-ausgang PNP oder NPNDrucksensoren SDE5 Merkmale• Drucksensor SDE5 als Druck-überwachung beim Einpress-vorgang von Stanzteilen • Drucksensor SDE5 als …Inline-variante” zur Druckbereichs-überwachung an einem Druck-luftschrauber.32023/02 – Änderungen vorbehalten d I nternet: /catalogue/...Drucksensoren SDE5PeripherieübersichtPeripherieübersicht4d I nternet: /catalogue/...Änderungen vorbehalten – 2023/0252023/02 – Änderungen vorbehalten d I nternet: /catalogue/...Drucksensoren SDE5TypenschlüsselWeitere Varianten können Sie über den Produktbaukasten bestellen a 12• Druckmessbereich • Ausgangsfunktion• Pneumatischer Anschluss • Elektrisches Zubehör• X-Teach-Punkt fest eingestellt•Y-Teach-Punkt fest eingestellt6d I nternet: /catalogue/...Änderungen vorbehalten – 2023/02Drucksensoren SDE5DatenblattFunktionSchaltausgang PNPAnalogausgangSchaltausgang NPNDrucksensoren SDE5 Datenblatt1)% FS = % des Messbereichsendwertes (fullscale)7 2023/02 – Änderungen vorbehalten d I nternet: /catalogue/...Drucksensoren SDE5DatenblattMäßige Korrosionsbeanspruchung. Innenraumanwendung bei der Kondensation auftreten darf. Außenliegende sichtbare Teile mit vorrangig dekorativer Anforderung an die Oberfläche, die in d irektem Kontakt zur umgebenden industrieüblichen Atmosphäre stehen.8d I nternet: /catalogue/...Änderungen vorbehalten – 2023/02Drucksensoren SDE5 Datenblatt9 2023/02 – Änderungen vorbehalten d I nternet: /catalogue/...Drucksensoren SDE5DatenblattqKernprogramm10d I nternet: /catalogue/...Änderungen vorbehalten – 2023/02Drucksensoren SDE5 Datenblatt11 2023/02 – Änderungen vorbehalten d I nternet: /catalogue/...Drucksensoren SDE5Bestellangaben – Produktbaukasten[1] G, W, G5, W5Nur in Kombination mit M8[2] Y Nicht kombinierbar mit O, C[3] X, Y Nicht kombinierbar mit FP, O1, C1, NFMuss bewertet werden, wenn O2, C2, O3, C3,und X oder Y gewählt wurdeIn Verbindung mit D10 nur eine Dezimalstelle zulässigSensor ohne Edittaste, keine Veränderung des Schaltpunktes möglich [4] Q4E, Q6E, T532E, T14ENicht in Kombination mit Druckeingang Z [5] P, N Nicht in Kombination mit Ausgangsfunktion NF[6] V Nur in Kombination mit Ausgangsfunktion NF[7] V Nur in Kombination mit B2 und X-Teach-Punkt im negativen Bereich, dann jedochMussangabe[8] V Nur in Kombination mit B2 und Y-Teach-Punkt im negativen Bereich, dann jedochMussangabe1)Zulässiger Wertebereich. Der Wert für den fest eingestellten Teach-Punkt muss allerdings innerhalb des gewählten Druckmessbereichs V1, B2, D2, D6, D10 liegen.Hinweis zu V1: Eingabe des Teachdrucks ohne Vorzeichen.Hinweis zu B2: Eingabe des Teachdrucks im Vakuum ohne Vorzeichen, aber mit nachgestelltem “V”, siehe [7] oder [8].12d I nternet: /catalogue/...Änderungen vorbehalten – 2023/02Drucksensoren SDE5 Zubehör1)Bei Bestellung über den Produktbaukasten a1213 2023/02 – Änderungen vorbehalten d I nternet: /catalogue/...。
美国 ALLsensor 微压传感器

A 型封装-低压型-放大 V 输出
量程
±0.25 inch
满度输出
±2V
0 - 0.5inch 4V
±1 mbar ±2V
±1 inch ±2V
0-1 inch
4V
±2.5inch ±2V
零位输出
2.25v
0.25v
2.25v
2.25v
0.25v
2.25v
量程 满度输出
±5 inch ±2V
0- 5 inch 4V
供电
量程 满度输出
精度级别 线性/迟滞 总误差 零位输出
最大:16VDC/ 典型:12VDC
工作温度:-25~+85℃ 补偿温度:0~50/70℃
0 –4inch 40mv
0 - 0.3 PSI 20mv
C:普通级 典型值:0.5%FS , 最大值: 1%FS 最大值:±1mv, (4inch:±1.5mv)
大气压力测量: 压力量程 600~1100mbar , 输出 60~110mv / 0.25V~4.25V(A/M 封装)
压力量程 0~170cmH2O/0~100cmH2O , 输出 0.25V~4.25V. 压力量程 0~4inchH2O/±4 inchH2O , 输出 0.25V~4.25V 压力量程 ±10 inchH2O/±5PSI/0~15PSIA, 数字输出 最小 12bit
压力量程 ±5 inch/±10 inch/±1PSI/±5PSI/±15PSI/0~15PSIA/±3 0PSI/0~30PSIA/ ±100PSI/0~100PSIA, 数字输出 最小 12bit
压力量程 600~1100mbar/20~32inch Hg , 数字输出 最小 12bit (A/PCB 封装)
紧凑型压力传感器系列PSE540安装与维护手册说明书

Installation & Maintenance ManualCompact Pressure SensorSeries PSE540NOTEFollow the instruc tions given below when handling the pressure sensor. Otherwise, the sensor may be damaged or may fail, thereby resulting in malfunction.•Do not drop, bring into collision with other objects or apply excessive shock to the unit (980m/s 2or more).•Do not pull the lead wire with force or lift the main unit by holding the lead wire. (Pulling strength less than 50N)•Do not insert wire or other articles into the pressure port.•Connect wires and cables correctly.•Do not perform wiring while power is on.•Do not wire with power cable or high-voltage cable in the same wire route.•Connect Terminal FG to ground when using a switching regulator obtained on the commercial market.•Install the air tube correctly in a safe area away from water and dust.The Pressure Sensor and this manual contain essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions.Do not disassemble, modify (inc luding c hange of printed circuit board) or repair.An injury or failure can result.Do not operate outside of the specification range.Fire, malfunction or sensor damage can result.Please use after confirming the specification.Do not operate in atmosphere of an inflammable, explosive or corrosive gas.Fire, an explosion and corrosion can result.This pressure sensor is not an explosion proof type.Model Indication Methodpacked together with it for shipment.Outline with Dimensions (in mm )SpecificationPressure or Vacuum1 to 5VDCAnalog outputPSE##-TFI53GBEMC Directive 89/336/EECEN61000-6-2:2001 Electromagnetic Compatibility (EMC). Generic standards - lmmunity for industrial environments.EN55011+A1:1998 Limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical radio-frequency equipment and light industrial environments.Safety InstructionsOutput SpecificationInternal Circuit and WiringVoltage output:1 to 5V Output impedance:Approx. 1kTo enquire about the product, please contact the following:URL PhoneAUSTRIA / (43) 2262-62 280 ITALY / (39) 02-92711BELGIUM / (32) 3-355 1464 NETHERLANDS / (31) 20-531 8888 CZECH REP. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700GREECE / (30) 1- 342 6076 SWITZERLAND / (41) 52-396 3131HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512IRELAND / (353) 1-403 9000 UNITED KINGDOM / (44) 1908-56 3888Connector Connecting/Disconnecting•When connecting the connector, insert it straight onto the pins holding the lever and connector body, and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks.•When disconnecting the connector, press the connector lever to disengage the lever claw from the square groove. Then pull the connector straight out.Attaching the connector to the lead wire•Strip the sensor wire as shown in the right figure.•The core of the corresponding color shown in the following table is put into the pin of the number printed on the e-con connector and pushed to the back.•Check that the above-mentioned preparation work has been performed correctly, then part A shown in the figure is pushed in by hand to make temporary connection.•Part A center is pressed straight in using a tool, such as pliers.•Re-use cannot be performed once the e-con connector has been completely crimped.•In case of connection failure such as incorrect order of wires or incomplete insertion, please use a new e-con connector.•or as detailed below.•Please contact connector manufacturer about catalogue.Connector Installation (continue)Color of Insulation Brown (DC + )N.C.Blue (DC - )Black (IN: 1 to 5VDC)Pin No.1234PSE200 Series PSE300 SeriesConnector for Sensor Lead WireLeverLeverInstallationObserve the specified tightening torque when connecting pipes.Refer to the following table for the appropriate torque values.Hold the sensor and insert it into the one-touch fitting carefully and securely all the way to the bottom.PSE##-TFI53GB。
HYDAC HDA 4748-H电子压力传感器说明书

E 18.332.2/11.13ElectronicPressure Transmitterwith HSI Sensor Recognition HDA 4748-HDescription:The pressure transmitter HDA 4748-H with HSI sensor recognition has been speciallydeveloped for use in conjunction with HYDAC measuring instruments HMG 500, HMG 510, HMG 3000, HMG 3010 and CMU 1000.For data transmission, the HDA 4748-H has an HSI interface(HYDAC Sensor Interface).The HSI sensors are automatically recognised via the HSI interface by the above-mentioned HYDAC measuring instruments and allnecessary basic device settings are taken from each sensor.Like all pressure transmitters of the HDA 4700 series, the HDA 4748-H also has a very accurate and robust sensor cell with a thin-film straingauge on a stainless steel membrane. It combines excellent technical specifications with a very compact design.Special features:● Fully automatic recognition by, and voltage supply from, HYDAC measuring instruments HMG 500, HMG 510, HMG 3000, HMG 3010 or CMU 1000● Automatic transfer of measuring range, measured value and measurement unit● Accuracy ≤ ± 0.25 % FS typ.● Highly robust sensor cell ● Very small temperature error ● Excellent EMC characteristics ● Excellent long term stability ● Very compact designTechnical data:Input dataMeasuring ranges 1) -1 .. 9; 16; 60; 100; 250; 400; 600;1000 barOverload pressures 20; 32; 120; 200; 500; 800; 1000;1600 barBurst pressures 100; 200; 300; 500; 1000; 2000; 2000;3000 barMechanical connection 1) G1/4 A DIN 3852 (20 Nm) (torque value)G1/2 DIN 3852 (40 Nm)Parts in contact with medium Mech. connection: Stainless steelSeal: FPMOutput data Output signal HSI (H YDAC S ensor I nterface)Automatic sensor recognition Accuracy to DIN 16086 ≤ ± 0.25 % FS typ. Max. setting≤ ± 0.5 % FS max.Accuracy at min. setting ≤ ± 0.15 % FS typ. (B.F.S.L.)≤ ± 0.25 % FS max.Temperature compensation ≤ ± 0.008 % FS / °C typ. Zero point≤ ± 0.015 % FS / °C max.Temperature compensation ≤ ± 0.008 % FS / °C typ. Over range≤ ± 0.015 % FS / °C max.Non-linearity at max. setting ≤ ± 0.3 % FS max. to DIN 16086Hysteresis ≤ ± 0.1 % FS max.Repeatability ≤ ± 0.05 % FS Rise time≤ 0.5 msLong-term drift≤ ± 0.1 % FS typ. / year Environmental conditionsCompensated temperature range -25 .. +85 °COperating temperature range 2) -40 .. +85 °C / -25 .. +85 °C Storage temperature range -40 .. +100 °CFluid temperature range 2) -40 .. +100 °C / -25 .. +100 °C markEN 61000-6-1 / 2 / 3 / 4 Vibration resistance to≤ 20 gDIN EN 60068-2-6 at 10 .. 500 Hz Protection class to IEC 60529 IP 67 (when an IP 67 connectoris used)Other data Voltage supply via HYDAC measuring instruments HMG 500, HMG 510, HMG 3000,HMG 3010 or CMU 1000Life expectancy > 10 million cycles0 .. 100 % FS Weight~ 150 gNote: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided. FS (F ull S cale) = relative to the complete measuring range, B.F.S.L .= B est F it S traight L ine1)1000 bar only with mechanical connection G 1/2 DIN 3852 and vice versa2)-25 °C with FPM seal, -40 °C on requestE 18.332.2/11.13326Dimensions:Note:The information in this brochure relates to the operating conditions and applications described.For applications or operating conditions not described, please contact the relevant technical department.Subject to technical modifications.HYDAC ELECTrONIC GMBHHauptstraße 27, D-66128 Saarbrücken Telephone +49 (0)6897 509-01 Fax +49 (0)6897 509-1726 E-mail:********************Internet: hex. SW27male electr. conn.5 poleelastomer profile gasket DIN 3869elastomer profile gasket DIN 3869hex. SW27optional O-ring20.35 x 1.78。
感应式压力传感器P500的产品说明说明书

| P500PRESSURE SENSOR DescriptionFeatures• Small Size (3/4” Hex)• External Hex for Easy Installation • Linear Amplified Output • Temperature Compensated • Superior Long-Term Stability • Low Power Consumption• Minimum Life Expectancy: Ten Million CyclesThe P500 incorporates Kavlico’s 4th generation ceramic capacitive sense element with the latest state of the art proprietary ASIC. Available in brass or stainless steel housings, this multi-purpose sensor is rugged by design. Highly reliable, the P500 is ideal for measuring a broad range of process media including hydrocarbon based fluids, air, and gases. The P500 package has a built-in Metri-Pack 150 series sealed electrical connector and is available with popular pressure connection thread options. The sensor is offered with seal materials suitable for diverse applications. Standard pressure ranges are available in PSI or Bar.Applications• Compressors • Process Controls• Instruments & Test Equipment • Sterilizers • Air Pressure• Oil & Fuel Pressure • Coolant Pressure• Agricultural Equipment• CNG & Natural Gas EnginesSPECIFICATIONSTECHNICAL SPECIFICATIONSPressure RangesPhysicalPerformanceElectricalPART NUMBER DESIGATION: P500-300-S-E 4 AVoutputN/CVsupplyGNDVENT HOLE (GAUGE)USE STANDARD OPENEND WRENCH OR SPECIALIZED SOCKET WRENCH ONLY19.1818.69.755.736HEXDATE CODE EXAMPLE: L0515UL LOGO (PRESSURE DEPENDENT)KAVLICO PART #(SEE EXAMPLE)PERMANENTLY IDENTIFY X X X X XDATE CODE11P500-XXX-X-X4XSHOWN19.09 1.575 MAX.752405.59.220Dimensions in mm [Inch]DIMENSIONSPressure Sensor with Electrical ConnectionPressure Connections and Recommended Installation Torque1/4 - 18 NPT 1/8 - 27 NPT Stud EndDIN 3852-B-G1/4External External External 25 Nm20 Nm20 NmTapped Hole DIN 3852-Y-G1/43/8-24 UNF-2A PER SAE J 1926/23/8-24 UNF-2B PER SAE J 1926/1Internal External Internal 15 Nm22 Nm22 NmPage 4CONTACT USAmericas+1 (800) 350 2727***************************************Europe, Middle East & Africa +359 (2) 809 1826****************************Asia Pacific*************************.com China +86 (21) 2306 1500Japan +81 (45) 277 7117Korea +82 (31) 601 2004India +91 (80) 67920890Rest of Asia +886 (2) 27602006 ext 2808Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice.Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF.All products are sold subject to Sensata’s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION ORDERING OPTIONSP500 Sensor, 0 - 16 Bar Absolute, Fluorosilicone Seal Material, 1/4 - 18 NPTA: With Mating Connector, w/12”, 18 AWG Leads C: Without Mating ConnectorAGENCY APPROVALS & CERTIFICATIONSEN 61326-1, 2006IEC 61000-4-2, 2001IEC 61000-4-3, 2006IEC 61000-4-8, 20012002/95/EC RoHS Directive File # SA10552。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
l l S e n s o r s
1994
ALL SENSORS Silicon Pressure Sensors
technology to reduce errors. Output changes due to temperature, warm-up stability, long-term stability, and position sensitivity are all significantly reduced when compared to conventional compensation methods. These sensors are intended for use with non-corrosive, non-ionic working fluids, such as air and dry gases. Packaging is designed to be mounted to a printed-circuit board. Our highly linear pressure sensors are typically used as components in high accuracy instrumentation for markets such as: medical, HVAC, mine safety, off-road vehicles, chemical analysis, and environmental.
MILLIVOLT OUTPUT MEDIUM PRESSURE SENSORS -
0.25% ~ 1% LINEARITY
• Common-mode pressure: 50 psig
Specifications:
• Supply voltage: 16 VDC max. • Ratiometric output
• Compensated temperature range: 0°C to 70°C • Operating temperature: -25°C to +85°C
0.25% Linearity
1% Linearity
Common-mode pressure: -10 to +10 psig
SURFACE MOUNT BASIC PRESSURE SENSORS
Features:
• Uses a silicon micromachined (MEMS) pressure sensor
in the most basic configuration
• Package is a ceramic surface mount configuration to provide the smallest footprint possible
• This series is intended for use with non-corrosive,
non-ionic working fluids such as air, dry gases and the like
Specifications:
• Operating temperature: -25°C-85°C
• Supply Voltage: 6 VDC
• Output of the device is ratiometric to the supply voltage
MINIATURE MILLIVOLT OUTPUT MEDIUM PRESSURE SENSORS - 0.5% LINEARITY; ASCX SERIES
Features:
• Based upon a proprietary package technology to reduce errors • Sensor housing has been designed specifically to reduce
package induced parasitic stress and strain
• Utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure
Specifications:
• Operating temperature: -25°C-105°C • Supply Voltage: +4.5-+5.5 VDC
• Output of the device is ratiometric to the supply voltage
Applications: Compatible to Sensym ASCX Series
Applications:• HVAC • Medical instrumentation • Environmental controls MILLIVOLT OUTPUT LOW PRESSURE SENSORS
Specifications:• Compensated temperature range: 0°C to 50°C • Operating temperature: -25°C to +85°C • Common-mode pressure: -10 to +10 psig • Supply voltage: 16 VDC max. • Ratiometric output
Features:
• Calibrated Zero and Span
• Based on proprietary technology to reduce all output offset or common mode errors
• Utilizes silicon, MEMS technology to provide very linear output to measured pressure
Applications:
• HVAC • Medical instrumentation • Environmental controls
Applications:• HVAC • Medical instrumentation • Environmental controls © Copyright 2011 Mouser Electronics。