标准范本-EN60335关于爬电距离和空气间隙的标准
合集下载
相关主题
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
degree 3 applies
Note: The pollution degree should need refer to part 2.
Pollution degree
>1mm
Tubular sheathed heating element
Pollution degree 1
29.1.2 clearance of supplement insulation
The minimum clearance is same as the basic insulation
The distance between enclosure and internal wire
The minimum clearances of basic insulation was 1.5mm
Rated impulse voltage V
330 500 800 1500 2500 4000 6000 8000 1000
Minimum clearance
mm
0.5 0.5 0.5 0.5 1.5 3.0 5.5 8.0 11.0
The clearance of basic insulation
Example 1 : Water kettle
Rating
: 220 – 240V 50Hz 2500 – 3000W
Rated voltage Rated impulse voltage
V
(V)
Overvoltage category
impulse voltage
The clearances of four insulation types:
1. Basic insulation 2. Supplementary insulation 3. Reinforced insulation 4. Functional insulation
Clause 29Clearances, Creepage distances and solid insulation爬电距离、电
气间隙和绝缘穿通距离 (Table 1)
Rated voltage
Rated impulse voltage
V
V
Overvoltage category
I
II
III
<=50
0.5
2500
1.5
4000
3.0
6000
5.5
8000
8.0
Βιβλιοθήκη Baidu
1000
11.0
How to find the minimum clearance
➢ Household appliance are in overvoltage category II ➢ Select the rated voltage ➢ Using the table 1 to find out the rated impulse voltage ➢ According to table 2, the minimum clearance could be found by rated
29.1.4 clearance of functional insulation
Between terminals
The functional insulation is between live parts of different potential
PTC Heating element
Hair straighter
330
500
800
>50 and <=150
800
1500
2500
>150 and <=300
1500
2500
4000
Minimum clearance (Table 2)
Rated impulse voltage V
Minimum clearance mm
330
0.5
500
0.5
800
0.5
1500
Special components for basic insulation
➢ The terminals of tubular sheathed heating elements counted 1mm, if the microenvironment is pollution degree 1.
➢Pollution degree 2 applies unless ➢Precautions have been taken to protect the insulation, in which case pollution 1
applies ➢The insulation is subjected to conductive pollution, in which case pollution
Hair straighter assembly
PTC heater
Different types of PTC Heating elements
Internal construction of PTC heating element
The clearance >=1mm
Kapton film Electrode plate
PTC heating plate
The clearance between surfaces of PTC heating elements may be reduced to 1mm
29.2 creepage distances
Step 1 (To find out the pollution degree)
I
II
III
<=50
330 500 800
>150 and <=150 800 1500 2500
Using category II
>150 and <=300 1500 2500 4000
220 – 240V
The rated impulse voltage was 2500V
29.1.1 clearances of basic insulation
29.1.3 clearance of reinforced insulation The reinforced insulation using the next step for rated impulse
voltage.
Between terminal and plastic enclosure
Note: The pollution degree should need refer to part 2.
Pollution degree
>1mm
Tubular sheathed heating element
Pollution degree 1
29.1.2 clearance of supplement insulation
The minimum clearance is same as the basic insulation
The distance between enclosure and internal wire
The minimum clearances of basic insulation was 1.5mm
Rated impulse voltage V
330 500 800 1500 2500 4000 6000 8000 1000
Minimum clearance
mm
0.5 0.5 0.5 0.5 1.5 3.0 5.5 8.0 11.0
The clearance of basic insulation
Example 1 : Water kettle
Rating
: 220 – 240V 50Hz 2500 – 3000W
Rated voltage Rated impulse voltage
V
(V)
Overvoltage category
impulse voltage
The clearances of four insulation types:
1. Basic insulation 2. Supplementary insulation 3. Reinforced insulation 4. Functional insulation
Clause 29Clearances, Creepage distances and solid insulation爬电距离、电
气间隙和绝缘穿通距离 (Table 1)
Rated voltage
Rated impulse voltage
V
V
Overvoltage category
I
II
III
<=50
0.5
2500
1.5
4000
3.0
6000
5.5
8000
8.0
Βιβλιοθήκη Baidu
1000
11.0
How to find the minimum clearance
➢ Household appliance are in overvoltage category II ➢ Select the rated voltage ➢ Using the table 1 to find out the rated impulse voltage ➢ According to table 2, the minimum clearance could be found by rated
29.1.4 clearance of functional insulation
Between terminals
The functional insulation is between live parts of different potential
PTC Heating element
Hair straighter
330
500
800
>50 and <=150
800
1500
2500
>150 and <=300
1500
2500
4000
Minimum clearance (Table 2)
Rated impulse voltage V
Minimum clearance mm
330
0.5
500
0.5
800
0.5
1500
Special components for basic insulation
➢ The terminals of tubular sheathed heating elements counted 1mm, if the microenvironment is pollution degree 1.
➢Pollution degree 2 applies unless ➢Precautions have been taken to protect the insulation, in which case pollution 1
applies ➢The insulation is subjected to conductive pollution, in which case pollution
Hair straighter assembly
PTC heater
Different types of PTC Heating elements
Internal construction of PTC heating element
The clearance >=1mm
Kapton film Electrode plate
PTC heating plate
The clearance between surfaces of PTC heating elements may be reduced to 1mm
29.2 creepage distances
Step 1 (To find out the pollution degree)
I
II
III
<=50
330 500 800
>150 and <=150 800 1500 2500
Using category II
>150 and <=300 1500 2500 4000
220 – 240V
The rated impulse voltage was 2500V
29.1.1 clearances of basic insulation
29.1.3 clearance of reinforced insulation The reinforced insulation using the next step for rated impulse
voltage.
Between terminal and plastic enclosure