总磷总氮的测定方法
水质中总氮总磷总钾的测定
水质中总氮总磷总钾的测定
总氮的测定:
1.准备好样品,将水样过滤,先用0.45微米的过滤膜过滤一下,去除颗粒物。
2.取10ml水样加入100ml锥形瓶,加入0.1g硫酸钾和2ml氢氧化钠溶液,用水稀释至刻度线。
3.加入5ml碘化钾-碘酸盐溶液,放置15分钟后,用0.01mol/L硫酸标准溶液滴定至深黄色。
4.测定同样方法制备空白试液。
按内容计算。
总磷的测定:
1.准备好样品,将水样过滤,同理用0.45微米的过滤膜过滤。
2.将样品10ml加入容量瓶,加入1ml浓硫酸和3ml过量的浓氢氧化钠溶液,加水至刻度线。
3.取100ml烧杯,用去离子水洗净,放置于磁力搅拌器上。
加入25ml上述制备液和2ml钼酸铵缓冲液,搅拌均匀。
4.加入3ml氧化钼-磷酸缓冲溶液,再加入1ml铵钼酸和1ml石墨炉调节,振荡均匀。
5.将混合液放入主体石墨管中,用灰化程序升温回收磷,进入石墨管。
6.进行原子吸收光谱测定,按照标准曲线计算。
总钾的测定:
1.准备好样品,将水样过滤,同理用0.45微米的过滤膜过滤。
2.取10ml水样加入烧杯中,加入2ml稀HNO3,搅拌均匀,放入微波消解炉中消解。
3.消解后,加入1g硫酸盐离子解决和5ml磷酸盐缓冲溶液,加稀氧化钾溶液调节pH值至7左右。
4.用去离子水加到50ml,用原子吸收光谱法进行测定。
5.按照标准曲线计算。
水质总氮总磷氨氮高锰酸盐指数的测定
水质总氮的测定——碱性过硫酸钾消解紫外分光光度法1.测定原理碱性过硫酸钾法: 过硫酸钾是强氧化剂, 在60℃以上水溶液中可进行如下分解产生原子态氧:K 2S2O8+ H2O 2 KHSO4+ [O]分解出的原子态氧在120~124℃下, 可使水样中含氮化合物的氮元素转化成硝酸盐, 消解后的溶液用紫外分光光度计于一定波长处测出吸光度, 从而计算出总氮的含量。
氮的最低检出浓度为0.050mg/L, 定上限为4mg/L。
2.水样的采集及其保存3.在水样采集后立即放入冰箱中或低于4℃的条件本保存, 但不得超过24h。
若水样的放置时间较长时, 可在1000mL水样中加入约0.5mL硫酸(p=1.84g /mL), 酸化到pH小于2, 并尽快测定。
4.试剂(1)碱性过硫酸钾溶液: 称取40g过硫酸钾, 另称取15g氢氧化钠溶于纯水中并稀释至1000mL, 溶液存贮于聚乙烯瓶中最长可保存一周。
(2)盐酸溶液(1+9): 按体积比混合(3)硝酸钾标准储备溶液CN=100mg/L:称取0.7218g在105-110℃烘箱中烘干4小时的优级纯硝酸钾溶于水中, 移至1000 mL容量瓶中, 用纯水稀释至标线在0~10℃保存, 可稳定六个月。
(4)硝酸钾标准使用液CN=10mg/L :用CN=100mg/L溶液稀释10倍而得, 使用时配制。
4、仪器紫外分光光度计、具塞比色管、移液管、医用手提式蒸气灭菌器、石英比色皿。
5.实验步骤(1)标准曲线的绘制: 分别取0, 0.50, 1.00 , 2.00, 3.00, 5.00, 7.00, 8.00ml 标准使用液于25 ml比色管中, 加水至10ml标线。
(2)向比色管中加入5ml碱性过硫酸钾溶液, 用纱布和线包扎紧, 在121℃中消煮1小时, 冷却至室温。
(3)加入1ml(1+9)盐酸, 定容至25 ml, 摇匀, 用光程长10mm比色皿, 在220 nm和275nm下测定吸光度。
总磷总氮的测定方法
总磷总氮的测定方法总磷和总氮的测定方法是环境分析和水质监测中的重要内容,这两个指标对于评估水体质量和判断水环境的污染程度有着重要的意义。
常用的总磷和总氮的测定方法包括光度法、分光光度法和化学分析法等。
1.光度法:光度法是一种利用样品溶液对特定波长光的吸收进行测定的方法。
对于总磷的测定,可以使用酚酞法。
首先,将样品中的总磷与酚酞试剂反应生成的红色络合物进行测定,根据红色络合物的吸收光强度来确定样品中总磷的浓度。
对于总氮的测定,可以使用硫酸邻苯二胺法。
样品中的总氮与硫酸邻苯二胺试剂反应生成蓝色络合物,根据蓝色络合物的吸光度来确定样品中总氮的浓度。
2.分光光度法:分光光度法是在光度法的基础上,利用光谱仪器进行测定的一种方法。
对于总磷的测定,可以使用酚酞法,并利用分光光度计测定酚酞-总磷络合物在特定波长的吸光度。
对于总氮的测定,可以使用吡啶甲酸盐法。
样品中的总氮与吡啶甲酸盐试剂反应生成红色络合物,利用分光光度计测定络合物在特定波长的吸光度来确定总氮的浓度。
3.化学分析法:化学分析法是通过化学反应来确定总磷和总氮的浓度的方法。
对于总磷的测定,可以使用酸高锰酸钾氧化法。
首先,将样品中的总磷氧化为五价磷,然后加入酸高锰酸钾溶液,在酸性条件下进行反应,使得溶液的颜色由紫色变为浅紫色。
根据颜色的变化来确定总磷的浓度。
对于总氮的测定,可以使用氨氮测定法。
将样品中的总氮转化为铵态氮,然后利用氨气与卤素之间的反应进行测定,根据反应的吸热量来测定总氮的浓度。
总结起来,总磷的测定方法主要包括光度法、分光光度法和化学分析法等,而总氮的测定方法主要包括光度法、分光光度法和化学分析法等。
在具体的实验中,应当根据实际需求选择合适的测定方法,并结合样品的性质和测定的条件进行合理的操作,以获得准确可靠的测定结果。
总磷总氮检测原理
总磷总氮检测原理
总磷总氮检测原理是通过化学分析方法,测定水样中的总磷和总氮含量。
具体分析步骤如下:
1. 总磷检测原理:首先,将水样中的总磷转化为磷酸盐。
这可以通过加入硫酸或过氧化氢来完成。
然后,使用分子吸收光谱法或者离子色谱法进行测定,通过比对标准曲线来确定总磷含量。
2. 总氮检测原理:首先,将水样中的有机氮转化为无机氮。
这可以通过加入碱性氢氧化物、氧化剂或者酸性溶液来实现。
然后,使用氨氮分析仪或者紫外分光光度法进行测定,通过比对标准曲线来确定总氮含量。
总磷和总氮的检测原理基于这两个元素在水环境中的存在形式和化学反应。
这些分析方法被广泛应用于环境监测、水质评价和水处理等领域。
通过测定水样中的总磷和总氮含量,可以评估水体的营养状况和污染程度,为水环境管理和保护提供科学依据。
离子色谱法测定地表水中总磷和总氮的含量
Dionex ICS1500 离 子 色 谱 仪; 科 导 SK20GT 超 声 波 仪:500W,
53kHz;ZW20S19W-Z589 紫外灯,波长 254nm;普析 TU-1950 紫外分光光
度计;SHIMADZU UV-2700 紫外分光光度计;优普超纯水制造系统:超
Hale Waihona Puke 纯水电阻率 18.24 MΩ·cm。
研究表明 [6][7],过氧化氢在紫外光条件下有大量羟基自由基能快速 生成 , 过程一般如下表示:
H 2O2 hv→ 2·OH ·OH + 含磷 / 氮化合物 → H 2O + NO3− / PO43−
在单独紫外光或过氧化氢存在下水体中的含磷 / 氮化合物的氧化消 解非常缓慢不彻底。两者同时作用于水样时便能产生协同作用产生大量 强氧化性、低选择性的羟基自由基,将水体中各类含磷 / 氮化合物消解 为简单的磷酸盐和硝酸盐,并且不产生二次污染,非常有利于后续离子 色谱的检测。考虑到超声波对过氧化氢消解的催化作用以及有利于水样 中固体颗粒的均匀分散作用,也引入超声波作为辅助手段。 1.2 仪器和试剂
Abstract: In this paper, the water sample was oxidized and digested under ultraviolet light and ultraviolet light-hydrogen peroxide system. The mass concentration of total nitrogen and total phosphorus in surface water was determined by ion chromatography. The method avoids the interference factor of the chemical reagent on the absorbance in the national standard method, and has high accuracy, high sensitivity and short time. The actual water sample was analyzed, the total nitrogen addition standard recovery rate was 97.0%~101%, and the total phosphorus spiked recovery rate was 97%~102%. The method is simple and convenient to operate, has good selectivity, good correlation, low detection limit, and all indexes meet analytical requirements, and can be used for analysis of total nitrogen and total phosphorus in water.
快速测定COD氨氮总磷的方法和步骤
快速测定COD氨氮总磷的方法和步骤一、水质COD氨氮总磷的检测应准备:1、待测水样、蒸馏水、废液杯、干净烧杯等。
2、1mL、2mL和5mL移液器多支,或1mL和5mL移液器各一支。
3、水质COD氨氮总磷快速检测仪一套,包括:31.COD氨氮总磷快速测定仪一台32.多功能快速消解仪一台33.几支比色管34.COD预制试剂一套、氨氮试剂一套、总磷试剂一套35.比色架、保护罩、清洁布、电源线等配件二、试剂的配置和储存1、COD试剂:无需配置,直接使用,避光保存。
2、氨氮试剂:无需配置,直接使用,避光保存。
3.总磷试剂:31.总磷试剂(1)100个样品:将整袋试剂溶解在100mL蒸馏水中;保持新鲜和冷藏。
32.总磷试剂(2)100个样品:将整袋试剂溶解在20mL蒸馏水中;保持新鲜和冷藏。
33.总磷试剂(3)100个样品:试剂瓶装,无需配置。
三、测量步骤和方法COD测定1、打开消解仪电源,选择COD消解方式(165℃.15min)。
12.打开主机电源并预热。
13.在比色管架中准备几个COD预制试剂管。
(200mg/L为低范围,200mg/L以上为高范围)14.精准量取2ml蒸馏水,加到空白反应管中。
(低和高范围需要分别做空白)2、精准吸取每份水样,分别加入到其他反应管中。
a.水样COD值为0200mg/L时,取2ml水样加入低量程预制试剂中;b.当水样的COD值为2001000mg/L时,取2ml水样加入到高效预制试剂中;c.当水样COD值为100010000mg/L时,将水样稀释10倍后,取2ml水样加入到高浓度在该范围的预先制备的试剂中;d.盖好并摇匀;当消解器达到温度时,蜂鸣器会短促鸣响,将消解管插入消解孔,盖上保护盖,按下“OK”键,消解仪开始计时消解。
氨氮的测定11.打开主机电源并预热。
12.在比色管架中准备一些干净干燥的比色管。
13.精准量取5ml蒸馏水,加入空白反应管中。
14.精准吸取每份水样,依次加入其他反应管中。
总磷总氮操作方法
总磷总氮操作方法
总磷和总氮是指水体中的磷和氮的总含量。
对于水体中总磷和总氮的操作方法如下:
1. 采集水样:根据需要采集水样,并在采集时避免污染。
2. 提取样品:将采集的水样经过过滤或沉淀处理,使其中的固体物质被去除,得到水样提取液。
3. 检测总磷:常用的总磷检测方法有壳聚糖磷酸盐(光度法)、钼酸还原法等。
根据不同的方法,按照相应的实验步骤和试剂使用说明进行操作,最终得到总磷的含量。
4. 检测总氮:常用的总氮检测方法有钝化电极法、紫外分光光度法等。
根据不同的方法,按照相应的实验步骤和试剂使用说明进行操作,最终得到总氮的含量。
5. 计算结果:根据实验测得的总磷和总氮含量,可以按照特定的计算公式计算出相应的浓度或质量浓度。
需要注意的是,操作前要根据具体情况选择适用的检测方法,并严格按照试剂使用说明和实验操作步骤进行操作,以保证结果的准确性。
此外,还需采取必要的
质量控制措施,如进行标准曲线法定量、平行测定等,以提高测定结果的可靠性。
总氮总磷分析流程
总氮总磷分析流程下载温馨提示:该文档是我店铺精心编制而成,希望大家下载以后,能够帮助大家解决实际的问题。
文档下载后可定制随意修改,请根据实际需要进行相应的调整和使用,谢谢!并且,本店铺为大家提供各种各样类型的实用资料,如教育随笔、日记赏析、句子摘抄、古诗大全、经典美文、话题作文、工作总结、词语解析、文案摘录、其他资料等等,如想了解不同资料格式和写法,敬请关注!Download tips: This document is carefully compiled by theeditor. I hope that after you download them,they can help yousolve practical problems. The document can be customized andmodified after downloading,please adjust and use it according toactual needs, thank you!In addition, our shop provides you with various types ofpractical materials,such as educational essays, diaryappreciation,sentence excerpts,ancient poems,classic articles,topic composition,work summary,word parsing,copy excerpts,other materials and so on,want to know different data formats andwriting methods,please pay attention!总氮总磷分析流程一、准备工作阶段。
在进行总氮总磷分析之前,需做好充分准备。
流动注射分析仪同时测定水样中总氮和总磷的分析
总氮的测定通常采用钾氧化铜法或氨氮分析仪法。本文介绍钾氧化铜法。实验要点如下:
1)试剂:氢氧化钠溶液、硫酸铜溶液、钾碘化钾溶液、氢氧化钾溶液、去离子水。
2)样品制备:将水样过滤,取100mL样品于奶酪布或滤纸上蒸干,转移至预先称量的石英瓶中,加10mL氢氧化钠溶液,用石英棒搅拌压实样品。
1)试剂:去离子水、钼酸铵-铵铬酸复合试剂、锕液。
2)样品制备:取100mL水样,用滤纸过滤,得到基体水样。在100mL基体水样中分别加入0mg/L、0.02mg/L、0.04mg/L、0.06mg/L、0.08mg/L、0.10mg/L的标准磷酸盐溶液,制成标准曲线系列标准污染水样。
3)LCK反应:取5mL基体水样和5mL钼酸铵-铵铬酸复合试剂混合,混匀后放置1h左右,使沉淀沉淀。取上清部分,如有必要进行滤清。然后取上清的1mL注入流动注射分析仪。
三、总结
流动注射分析仪具有自动化程度高、重现性好、样品消耗少等优点,可以快速、精确地测定水质中的各种成分,为水环境监测提供了有力的技术支持。在测定水样中总氮和总磷时,钾氧化铜法和钼酸铵分光光度法分别是经典的测定方法,各自具有优缺点,需要在具体应用中进行选择。
3)LCK反应:取5mL样品与5mL硫酸铜溶液混合,荧光反应约15min,然后加入5mL钾碘化钾溶液,振荡均匀10s后注入流动注射分析仪。
4)仪器条件:波长620nm,试剂流速1.5mL/min,样品体积100μL。
5)数据分析:根据标准曲线计算出样品中总氮的浓度。
总磷的测定通常采用钼酸铵分光光度法。实验要点如下:
流动注射分析仪同时测定水样中总氮和总磷的分析
流动注射分析仪(Flow Injection Analysis,FIA)是一种自动连续进样、连续流动、快速响应的分析技术,可用于水环境中氮、磷等营养元素的快速分析。本文以测定水样中总氮和总磷为例,介绍流动注射分析仪的原理和方法。
城市污泥总氮、总磷
文章编号:10002582X(2010) 032099204城市污泥总氮、总磷消解测定方法陈大勇1 , 王里奥1 , 罗书鸾2 , 马培东1 , 陶玉1(1. 重庆大学资源及环境科学学院, 重庆400044 ;2. 中化重庆涪陵化工有限公司, 重庆408000)收稿日期:2009210219基金项目:重庆市市政管理委员会项目(Z200521255002)作者简介:陈大勇(19732) ,男,重庆大学讲师,博士研究生,主要从事固体废弃物处理与资源化利用研究。
王里奥(联系人) ,女,重庆大学教授,博士生导师, (E2mail) wang65111477 @yahoo. com. cn。
摘要:设计了正交实验并分析了H2O2 与H2 SO4 消解污泥过程影响因素,在测定总氮时H2O2 添加次数在0. 1 水平下具有显著性,而H2O2 用量和H2 SO4 用量对总氮的测定影响较小,较优的消解方案: H2O2 添加次数为3 次、每次消耗为0. 25 mL , H2 SO4 用量为1 mL ;在测定总磷时H2O2 添加次数在0. 01 水平下具有显著性, H2O2 单次用量在0. 05 水平下具有显著性,而H2 SO4用量对总氮的测定影响较小,较优的消解方案: H2O2 添加次数为3 次,每次消耗为0. 25 mL ,H2 SO4 用量为5 mL 。
综合考虑,总氮、总磷测定方法的最佳方案即H2O2 添加次数为3 次,每次消耗为0. 25 mL ,H2 SO4 用量为5 mL 。
按照该消解方案,测出总氮的回收率在98. 53 %~101.80 % ,总磷的回收率在97. 07 %~101. 67 %。
关键词:污泥;总氮;总磷;消解;正交实验中图分类号:X705 文献标志码:AA digesting measurement method of municipal sewage sludge’s TNand TPCHEN Da2yong1 , WANGLi2ao1 , LUO Shu2luan2 , MA Pei2dong1 , TAO Yu1(1. College of Resources and Environmental Science , Chongqing University , Chongqing 400044 , P. R. China ;2. SINOCHEM Fuling Chongqing Chemical Indust ry CO. , L TD. , Chongqing 408000 , P. R. China)Abstract : Paramet ric st udy wit h ort hogonal experiment is carried out for digestion of municipal sewagesludge with H2O2 and H2 SO4 . For TN , t he adding time of H2O2 is significant at 0. 1 level , whil st t hedosages of H2O2 and H2 SO4 are less significant . The bet ter digestion scheme is t hat the number of addingtime of H2O2 is t hree and t he dosages of H2O2 and H2 SO4 are 0. 25 mL and 1 mL , respectively. And forTP , t he adding time of H2O2 is significant at 0. 01 level , and the dosage of H2O2 is significant at 0. 05level. However , t he dosage of H2 SO4 is less significant . Thus , t he bet ter digestion scheme is t hat t headding time of H2O2 is t hree and t he dosages of H2O2 and H2 SO4 are 0. 25 and 5mL , respectively.Combining t he two schemes , t he optimal scheme of sludge digestion is t hree times for H2O2 adding and 0.25 and 5mL for t he dosages of H2O2 and H2 SO4 , respectively. Wit h t he test , the recovery rate of TN isbetween 98. 53 % and 101. 80 % , while t he recovery rate of TP is between 97. 07 %and 101. 67 %.Key words : sewage sludge ;total nit rogen ;total p hosp horus ;digestion ;ort hogonal experiment随着社会的发展,城市人口的增加,工业废水与生活污水的排放量日益增多, 污泥的产出量迅速增加[1 ] 。
[整理版]总磷、总氮的测定方法
总磷、总氮的测定方法水质总氮的测定碱性过硫酸钾消解紫外分光光度法1.1主题内容本标准规定了用碱性过硫酸钾在120~124℃消解、紫外分光光度测定水中总氮的方法。
1.2适用范围本标准适用于地面水、地下水的测定。
本法可测定水中亚硝酸盐氮、硝酸盐氮、无机铵盐、溶解态氨及大部分有机含氮化合物中氮的总和。
氮的最低检出浓度为0.050mg/L,测定上限为4 mg/L。
本方法的摩尔吸光系数为1.47×103L.mol-1.cm-1。
测定中干扰物主要是碘离子与溴离子,碘离子相对于总氮含量的2.2倍以上,溴离子相对于总氮含量的3.4倍以上有干扰。
某些有机物在本法规定的测定条件下不能完全转化为硝酸盐时对测定有影响。
2.定义2.1可滤性总氮:指水中可溶性及含可滤性固体(小于0.45μm颗粒物)的含氮量。
2.2总氮:指可溶性及悬浮颗粒中的含氮量。
3、原理在60℃以上水溶液中,过硫酸钾可分解产生硫酸氢钾和原子态氧,硫酸氢钾在溶液中离解而产生氢离子,故在氢氧化钠的碱性介质中可促使分解过程趋于完全。
分解出的原子态氧在120~124℃条件下,可使水样中含氮化合物的氮元素转化为硝酸盐。
并且在此过程中有机物同时被氧化分解。
可用紫外分光光度法于波长220和275nm处,分别测出吸光度A220及A275按或(1)求出校正吸光度A:A = A220 —A275 (1)按A 值查校准曲线并计算总氮(以N03—N计)含量。
4、试剂和材料除非(4.1)另有说明外,分析时均使用符合国家标准或专业标准的分析纯试剂。
4.1水,无氨。
按下述方法之一制备:4.1.1离子交换法:将1000ml蒸馏水通过一个强酸性阳离子交换树脂(氢型)柱,流出液收集在带有磨口玻璃塞的玻璃瓶中。
4.1.2蒸馏法:在1000mL蒸馏水中,加入0.1ml硫酸(ρ=1.84g/ml),并在全玻璃蒸馏器中重蒸馏。
弃去前50ml馏出液,然后将约800ml馏出液收集在带有磨口玻璃塞的玻璃瓶中。
水中总氮总磷的测定
水质监测—水中总氮总磷的测定一、意义目前,封闭性水域的富营养化问题已相当严重,引起人们的普遍重视。
水中的总氮、总磷的含量在一定程度上能反映出水环境富营养化的情况,因此总氮总磷含量的测定已成为水研究中必不可少的内容。
过硫酸盐氧化法可同时测定水中的总氮总磷,方法简便快速,效率高,已成为常规的测定方法。
二、目的1、掌握过硫酸盐氧化法测定氮、磷的原理2、掌握751分光光度计的使用方法三、原理过硫酸盐在60o C的水溶液中可水解成H+和O2,即2K2S2O8+2H2O ---4KHSO4+O2。
将1mol的K2S2O8中加入1molNaOH,反应开始呈碱性(初始PH值为12.57),可将水中的氮氧化为硝酸盐。
由于氧化反应生成大量的H+,反应后的溶液呈酸性(PH值为2.12),可将磷氧化为磷酸盐。
因此水中的总氮、总磷可在一种氧化剂中依次完成氧化,氧化液经分光光度计比色,可快速测得总氮总磷,效率高于以往的凯氏法。
四、仪器名称规格数量751分光光度计 1移液管 5ml 1手提式高压消毒器 1具塞比色管 50ml 7分析天平 1容量瓶 100ml 7 50ml 7硫酸纸 6*6cm 1五、试剂所有试剂均用分析纯等级,用去离子蒸馏水配制。
1. 氧化剂溶液称取20g过硫酸钾和3gNaOH,溶于水中并稀释至1000ml。
2. 硝酸盐氮标准液称取0.7218gKNO3 (105℃烘干后称),溶解后定容至1000ml,此溶液为100ug/ml的硝酸盐溶液。
3. 磷酸盐标准液称取0.4394g经105---1100 C干燥两小时的磷酸二氢钾,用水溶解后加入1:1的硫酸溶液1ml,再用水稀释至1000ml,此溶液为100ug/ml的磷贮备液。
4. 3.5mol硫酸的钼酸铵锑贮备液量取194.6ml浓硫酸,缓缓加到405ml蒸馏水中,不断搅拌,冷却。
另称取钼酸铵20g溶于300ml蒸馏水中,然后将上述硫酸溶液缓缓倒入钼酸铵溶液中,不断进行搅拌,再加100ml 0.5%酒石酸锑钾溶液,摇匀,贮于棕色瓶中保存。
水中总磷和总氮含量的离子色谱测定法
水中总磷和总氮含量的离子色谱测定法丁明军;杨慧中【摘要】采用紫外光-臭氧氧化结合离子色谱法对氧化消解后的水样同时进行总磷和总氮的测定.配制Na2CO3/NaHCO3淋洗液,采用1 mL定量环,大体积直接进样.在优化工作条件下,总磷在0.05~5.00 mg/L,总氮在0.10~10.0 mg/L范围内线性良好,线性相关系数分别为0.9999和0.9998,总磷和总氮检出限为分别3.60和4.57 μg/L;总磷和总氮的检测相对标准偏差(RSD)分别低于4.9%和4.1%,总磷加标回收率为95.0%~105.0%,总氮加标回收率为93.0%~103.0%.自然环境水样检测与真实值相对偏差小于4.2%.本方法选择性好,灵敏度高,精密度和准确度高,用于实际水样中总磷和总氮含量测定的结果与国标法(GB11894-89,GB11893-89)基本一致.%An ion chromatography combined with ultraviolet-ozone oxidation procedure was proposed for detecting total phosphorus (TP) and total nitrogen (TN) simultaneously in water samples. The mixed solution ofNa2CO3/NaHCO3 was used as eluent, and the samples were injected with 1 mL large volume loop directly. Under the optimal conditions, TP concentration displays linear relationship in the range of 0. 05-5. 00 mg/L and TN concentration in the range of 0. 10 -10. 00 mg/L. The correlation coefficient of curve was 0. 9999 and 0. 9998 respectively. The detection limit of TP was 3. 60 μg/L and that of TN was 4. 57 μg/L. The relative standard deviations (RSD) of TP and TN were less than 4. 9 and 4. 1% respectively. The standard addition recoveries of TP were from 95. 0% to 105. 0%, and those of TN were from 93. 0% tol03. 0%. The relative error for the analysis of natural water samples to the standard were less than 4. 2%.The method proposed has good selectivity and high sensitivity, as well as precision. The determination results agree well with those obtained by the National standard method.【期刊名称】《分析化学》【年(卷),期】2012(040)003【总页数】5页(P381-385)【关键词】离子色谱法;紫外光-臭氧氧化;总磷;总氮【作者】丁明军;杨慧中【作者单位】教育部轻工过程先进控制重点实验室,江南大学,无锡214122;教育部轻工过程先进控制重点实验室,江南大学,无锡214122【正文语种】中文总磷和总氮引起的水体富营养化[1]是各国十分重视的全球性重大环境问题[2,3]。
沉积物中总氮总磷测定
四)沉积物总磷测定方法---SMT方法概述:SMT (The Standards,Measurements and Testing Programme)是欧洲标准测试委员会框架下发展的淡水沉积物磷形态分离方法,是一种标准的测试程序。
对于在湖泊修复中水质的监测和水资源领域的管理,尤其是实验室分析过程的质量保证和数据可比性中是一种很有价值的测试方法。
磷是湖泊生态系统中一种重要的生源要素,同时也是引起水体富营养化的重要因素,磷在海-陆相互作用中的迁移、循环会直接影响到水体的初级生产力,并因此影响到全球的碳循环。
此外,沉积物中总磷(TP )含量增加主要来自铁、铝磷(Fe/AI-P ),其次是有机磷(OP)并且TP和无机磷(IP)之间呈现显著正相关关系,同时,沉积物中TP分布主要受IP控制。
因此,研究沉积物中磷是揭示湖泊富营养化的其中一个限制性因子。
相关研究主要利用此方法测定了总磷含量、与各形态磷、有机质以及与沉积物的理化性质之间的相关关系等,有助于研究水体中磷的形态、动态循环以及磷在水-沉积物界面的迁移转化过程,以期为湖泊富营养化中磷循环机制提供科学的理论依据。
1、方法原理经高温灰化,沉积物样品中的含磷矿物及有机磷化合物全部转化为可溶性的正磷酸盐,在酸性条件下与钼锑抗显色剂反应生成磷钼蓝,在880 nm 波长出测定吸光度。
在一定浓度范围内,样品中的总磷含量与吸光度值符合朗伯比尔定律。
2、需要的设备与实验条件所需要设备主要均为实验室常用设备,主要包括紫外分光光度计、高压灭菌锅以及常规实验器皿等,一般实验室均有条件完成该项工作。
3、所需试剂及操作步骤3.1 所需试剂(1)5 mol L-1 H2SO4:70 mL浓硫酸溶于500 mL水中存储在玻璃瓶中,常温下保存;(2)酒石酸锑钾溶液:准确称取1.3715 g酒石酸锑钾(C8H4K2O12Sb2)于500 mL容量瓶中定容,充分摇匀后将该溶液贮存在棕色或其他试剂瓶(玻璃瓶)中,将其置于4 C下保存。
总磷、总氮检测步骤
5、分析步骤:(1)取25mL样品于具塞刻度管中。
取时应仔细摇匀,以得到溶解部分和悬浮部分均具有代表性的试样。
如样品中含磷浓度较高,试样体积可以减少。
(2)消解:向试样中加4mL过硫酸钾,将具塞刻度管的盖塞紧后,用一小块布和线将玻璃塞扎紧(或用其他方法固定),放在大烧杯中置于高压蒸汽消毒器中加热,待压力达1.1kg/cm2,相应温度为120℃时、保持30min后停止加热。
待压力表读数降至零后,取出放冷。
然后用水稀释至标线。
注:如用硫酸保存水样。
当用过硫酸钾消解时,需先将试样调至中性(3)发色:分别向各份消解液中加入1mL抗坏血酸溶液混匀,30s 后加2mL钼酸盐溶液充分混匀。
注:①如试样中含有浊度或色度时,需要配置一个空白试样(消解后用水稀释至标线)然后向试样中加入3ml浊度-色度补偿液,但不加抗坏血酸溶液和钼酸盐溶液。
然后从试样的吸光度中扣除空白试样的吸光度。
②砷大于2mg/L干扰测定,用硫代硫酸钠去除。
硫化物大于2mg/ L干扰测定,通氮气去除。
铬大于50mg/L干扰测定,用亚硫酸钠去除。
(4)分光光度测量:使用分光光度计时先在580nm处放入比色管套架处一张白纸片,看是否是黄的光,然后查看比色皿配套性检验,在波长为600nm处测定t%值两个比色皿相减范围在0.5%即可以开始测试室温下放置15min后,使用光程为30mm比色皿,在700nm波长下,以水做参比,测定吸光度。
扣除空白试验的吸光度后,从工作曲线(5)上查得磷的含量。
注:如显色时室温低于13℃,可在20~30℃水花上显色15min即可。
(5)工作曲线的绘制:取7支具塞刻度管分别加入0.0,0.50,1.00,3.00,5.00,10.0,15.0mL磷酸盐标准溶液。
加水至25mL。
然后按测定步骤5进行处理。
以水做参比,测定吸光度。
扣除空白试验的吸光度后,和对应的磷的含量绘制工作曲线。
(6)结果的表示:总磷含量以C(mg/L)表示,按下式计算:P=m/v,式中:m——试样测得含磷量,µg;V——测定用试样体积,m(1)用无分度吸管取10.00mL试样(CN超过100mg/L)时,可减少取作量并加水稀释至10mL)置于比色管中。
水质检测中总氮、总磷联合测定方法验证
水质检测中总氮、总磷联合测定方法验证摘要本文介绍总氮、总磷联合测定的一种方法。
实验中,调整了消解过程的氧化剂用量和酸度,以含有氮和磷的混合标准溶液配制一系列标准样品,经高温、高压消解后,分别进行比色,测定样品。
关键词总氮和总磷;氧化剂;常规方法;回收率;联合测定1 概述1.1 总氮的测定(常规方法)总氮是水体中有机氮及无机氮化物(氨氮、亚硝酸盐氮和硝酸盐氮)之和。
测定总氮的常规方法是应用碱式过硫酸盐氧化法。
120℃碱性条件,K2S2O8+H20→2KHSO4+1/2O2 KHSO4→K++HSO4-,HSO4ˉ→H++SO42ˉ,氢氧根离子中和氢离子使过硫酸钾分解完全,用过硫酸盐做氧化剂,在120℃左右消解30min,使水体中氨氮、亚硝酸盐氮被氧化成硝酸盐氮,也使水体中大部分的有机氮化合物氧化成硝酸盐氮,在氧化液pH约为2的条件下,用紫外分光光度法分别于波长220nm与275nm处,用10mm石英比色皿测定吸光度值而求得总氮含量。
1.2 总磷的测定(常规方法)总磷是水体中各种无机磷(主要是正磷酸盐及缩合磷酸盐)和有机磷酸盐之和。
测定总磷的常规方法是应用酸式过硫酸盐氧化法。
总磷分析分成二步,第一步为总磷氧化,在酸性条件下,应用过硫酸盐做强氧化剂,在120℃氧化30min,使水体中的无机磷酸盐及有机磷酸盐氧化成正磷酸盐。
第二步是显色,正磷酸盐与钼酸铵、酒石酸锑钾反应生成磷酸杂多酸,被还原剂抗坏血酸还原生成蓝色络合物,即磷钼蓝。
在700nm波长处,30mm玻璃比色皿条件下测其吸光度值而求得总磷含量。
1.3 用过硫酸盐法联合测定总氮和总磷现在水体监测时,往往要求同时测定水体中的总氮和总磷,分别测定这二个项目既耗时又增加成本。
采用《环境科学》中刊登的“用过硫酸盐氧化法同时测定水体中的总氮和总磷”这个方法,既简便又高效。
针对污水处理厂生物脱磷除磷工艺,对出水用总氮、总磷联合测定方法进行验证。
2 实验部分2.1 试剂(均使用分析纯试剂)1)氧化剂溶液。
总磷总氮检测步骤
总磷总氮检测步骤总磷和总氮是水体中重要的水质指标,用于评估水体的富营养化程度和水质的好坏。
以下是总磷和总氮的检测步骤。
总磷检测步骤:1.样品采集:在需要检测总磷的水体中,使用无铜、无锌的采样瓶采集水样,并避免接触容器壁。
2.预处理:将采集到的水样过滤掉较大的悬浮物,然后将水样进行酸化处理以使总磷主要以无机磷形式存在。
可以使用硫酸或盐酸进行酸化,并根据样品pH值调整酸量。
3.提取:将酸化处理过的水样倒入提取瓶中,加入一定量的提取剂(如过硫酸铵)和催化剂(如铵钼酸、钼酸铵),形成一种含铵盐和钼酸盐的混合溶液。
4.水样反应:将提取瓶密封并置于恒温水浴中,在适当的温度下进行水样反应。
反应的时间和温度取决于具体实验方法的要求。
5.光度测定:根据不同的实验方法,在反应后,使用分光光度计或相关设备测定反应后的溶液的吸光度。
一般来说,总磷的吸光度与其浓度成正比。
6.计算:根据测定结果和标准曲线,计算出样品中总磷的浓度。
常见的计算公式包括线性回归方程、比色同步方程等。
7.结果分析和报告:对检测结果进行分析和解释,并编写检测报告。
总氮检测步骤:1.样品采集:使用无铜、无锌的采样瓶采集水样,并避免接触容器壁。
样品分为总氮和氨氮两部分进行分析。
2.预处理:将采集到的水样过滤掉较大的悬浮物,然后将水样进行酸化处理以使总氮主要以无机氮形式存在。
可以使用硫酸或盐酸进行酸化,并根据样品pH值调整酸量。
3. 提取:将酸化处理过的水样加入一定量的外标(aniline solution)和还原剂(如亚硫酸钠),并进行外标校正。
将提取瓶密封并置于恒温水浴中,在适当的温度下进行水样反应,使总氮转化为氨氮。
4.氨氮测定:使用电极或分光光度计测定反应生成的氨氮的浓度。
一般来说,氨氮的浓度与其吸光度或电极测得的电位成正比。
5.计算:将氨氮的浓度转化为总氮的浓度,计算出样品中总氮的含量。
考虑到样品预处理过程中可能引入的误差,需要进行外标校正和恢复率计算。
COD_总氮_总磷_仪器分析方法
1
化学需氧量(COD)
COD的定义
指在强酸并加热条件下,用重铬酸钾作为氧化剂处理水样时所消 耗氧化剂的量,以氧的mg/L来表示。 它反映了水中受还原性物质污染的程度。 (《水和废水监测分析方法》第四版) COD测试是使用一种强氧化剂(重铬酸钾),强酸并且通过加热使 有机碳成为二氧化碳和水; 是一种间接测量有机物的方法,测量分解有机物氧化剂的消耗量: 消耗量多 = 有机物浓度高
21
常用分析方法
紫外法
偶氮比色法
离子色谱法 气相分子吸收法 ET1151M采用的是可见分光光度法,测量波长为420nm。
22
总氮分析系统
23
仪器测量方法
美国EPA认可方法。 系统由配套试剂、消解器和比色 测量三部分组成。
可以同时分析多个样品
总氮测量分为三个步骤:
消解
显色
测量
24
常用来表示总氮的单位有: mg/L N 和 mg/L NO3- 。记录测量结果 时应注意区别。它们之间的换算关系如下:
N 原子量 = 14 NO3- 分子量 = 14 + (16 x 3) = 62 所以 1mg/L NO3- = (14/62) mg/L N = 0.23 mg/L N 1mg/L N = (62/14) mg/L NO 3- = 4.43 mg/L NO3-
35
常用分析方法
正磷酸盐:离子色谱法
钼锑抗光度法
氯化亚锡还原钼蓝法(灵敏度较低,干扰较多) 孔雀绿-磷钼杂多酸法
ET1151M采用的是钼锑抗光度法,测量波长为610nm。
36
总氮分析系统
37
仪器测量方法
总氮、总磷的测定
总氮、总磷的测定实验原理:水样中的有机氮磷被碱性过硫酸钾氧化成无机氮磷,然后用营养盐自动分析仪测定NO3-N和PO4-P的含量。
试剂配制:1、过硫酸钾的纯化:取80g K2S2O8,加500ml水,70-80℃水浴中溶解,置于冰水混合物中冷却,析出晶体后,倾去上清液,再加入500ml水,70-80℃水浴中溶解,冰水混合物中冷却,抽滤。
晶体放入盛有浓硫酸的干燥器中,干燥,备用。
2 L烧杯 1.5 L二次水+240 g K2S2O81 L烧杯0.75 L二次水+120 g K2S2O82、EDTA贮备液的配制:EDTA固体105℃烘干后,准确称取0.1862g,溶于二次水中,转移至100ml容量瓶中,定容,浓度为10mmol/dm3。
3、有机磷标准贮备液的配制:准确称取0.02136g干燥好的AMP,溶于二次水中,转移至100ml容量瓶中,定容,浓度为500μmol/dm3。
4、氧化剂:50g 纯化后的K2S2O8和30g H3BO3溶于1dm3 0.375M ( 15g )的NaOH溶液中。
5、氨性缓冲液:134g NH4Cl溶于400ml水中,加入2ml 氨水,调pH至7.4±0.1。
实验步骤:1、EDTA使用液:取10ml EDTA 贮备液稀释至100ml。
2、PO43-使用液:取0.5ml 贮备液稀释至100ml,浓度大约为50μmol/dm3。
03、有机磷标准使用液:取5ml 贮备液稀释至100ml,浓度大约为25μmol/dm3。
4、标准系列:按下表取EDTA使用液和PO43-使用液,用二次水35、取50cm水样至氧化瓶中,加入5cm氧化剂,拧紧瓶塞,高压釜中压热氧化0.5h,冷却至室温后,取5.0cm3至50cm3比色管中,加入1cm3氨性缓冲液,稀释至50cm3,转入塑料瓶中,测定氮;氧化瓶中剩余水样转入塑料瓶中,测定磷。
POP、PON的测量氧化剂:30克过硫酸钾(纯化),15克硼酸溶解于140ml 1.5M(60g/l)氢氧化钠溶液中在500ml容量瓶中定容(milli-Q水配制,室温,棕色瓶避光保存,当天配制)。
总磷实验步骤
总磷实验在水体中,有机氮和无机氮化物含量增加,消耗溶解氧,使水体质量恶化。
磷类物质含量过量造成澡类过度繁殖,使水质透明度降低,水质变坏。
因此,总氮、总磷是衡量水质的重要指标。
总氮(TN)和总磷(TP)是《地表水环境质量标准》(GB3838-2002)中的基本项目,是地表水体富营养化的重要指标,其标准分析方法分别为碱性过硫酸钾消解紫外分光光度法(GB11894-89)和过硫酸钾消解钼酸铵分光光度法(GB11893-89)。
1、总磷的测定钼酸铵分光光度法用过硫酸钾(或硝酸-高氯酸)为氧化剂,将未经过滤的水样消解,用钼酸铵分光光度测定总磷的方法。
总磷包括溶解的、颗粒的、有机的和无机磷。
本标准适用于地面水、污水和工业废水。
取25mL试料,本标准的最低检出浓度为0.01mg/L,测定上限为0.6mg/L。
在酸性条件下,砷、铬、硫干扰测定。
2原理在中性条件下用过硫酸钾(或硝酸-高氯酸)使试样消解,将所含磷全部氧化为正磷酸盐。
在酸性介质中,正磷酸盐与钼酸铵反应,在锑盐存在下生成磷钼杂多酸后,立即被抗坏血酸还原,生成蓝色的络合物。
3试剂本标准所用试剂除另有说明外,均应使用符合国家标准或专业标准的分析试剂和蒸馏水或同等纯度的水。
3.1硫酸(H2SO4),密度为1.84g/mL。
3.2硝酸(HNO3),密度为1.4g/mL。
3.3高氯酸(HClO4),优级纯,密度为1.68g/mL。
3.4硫酸(H2SO4),1:1。
3.5硫酸,约c(1/2H2SO4)=1mo1/L:将27mL硫酸(3.1)加入到973mL 水中。
3.6氢氧化钠(NaOH),1mo1/L溶液:将40g氢氧化钠溶于水并稀释至1000mL。
3.7氢氧化钠(NaOH),6mo1/L溶液;将240g氢氧化钠溶于水并稀释至1000mL。
3.8过硫酸钾,50g/L溶液:将5g过硫酸钾(K2S2O8)溶解干水,并稀释至100mL。
3.9抗坏血酸,100g/L溶液:溶解10g抗坏血酸(C6H8O6)于水中,并稀释至100mL。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
总磷、总氮的测定方法水质总氮的测定碱性过硫酸钾消解紫外分光光度法1.1主题内容本标准规定了用碱性过硫酸钾在120~124℃消解、紫外分光光度测定水中总氮的方法。
1.2适用范围本标准适用于地面水、地下水的测定。
本法可测定水中亚硝酸盐氮、硝酸盐氮、无机铵盐、溶解态氨及大部分有机含氮化合物中氮的总和。
氮的最低检出浓度为0.050mg/L,测定上限为4 mg/L。
本方法的摩尔吸光系数为1.47×103L.mol-1.cm-1。
测定中干扰物主要是碘离子与溴离子,碘离子相对于总氮含量的2.2倍以上,溴离子相对于总氮含量的3.4倍以上有干扰。
某些有机物在本法规定的测定条件下不能完全转化为硝酸盐时对测定有影响。
2.定义2.1可滤性总氮:指水中可溶性及含可滤性固体(小于0.45μm颗粒物)的含氮量。
2.2总氮:指可溶性及悬浮颗粒中的含氮量。
3、原理在60℃以上水溶液中,过硫酸钾可分解产生硫酸氢钾和原子态氧,硫酸氢钾在溶液中离解而产生氢离子,故在氢氧化钠的碱性介质中可促使分解过程趋于完全。
分解出的原子态氧在120~124℃条件下,可使水样中含氮化合物的氮元素转化为硝酸盐。
并且在此过程中有机物同时被氧化分解。
可用紫外分光光度法于波长220和275nm处,分别测出吸光度A220及A275按或(1)求出校正吸光度A:A = A220 —A275 (1)按A 值查校准曲线并计算总氮(以N03—N计)含量。
4、试剂和材料除非(4.1)另有说明外,分析时均使用符合国家标准或专业标准的分析纯试剂。
4.1水,无氨。
按下述方法之一制备:4.1.1离子交换法:将1000ml蒸馏水通过一个强酸性阳离子交换树脂(氢型)柱,流出液收集在带有磨口玻璃塞的玻璃瓶中。
4.1.2蒸馏法:在1000mL蒸馏水中,加入0.1ml硫酸(ρ=1.84g/ml),并在全玻璃蒸馏器中重蒸馏。
弃去前50ml馏出液,然后将约800ml馏出液收集在带有磨口玻璃塞的玻璃瓶中。
4.2氢氧化钠溶液,200g/L:称取20g氢氧化钠(NaOH),溶于水(4.1)中,稀释至100ml。
3氢氧化钠溶液,200g/L:将(4.2)溶液稀释10倍而得。
4.4碱性过硫酸钾溶液,称取40g过硫酸钾(K2S2O8),另称取15g氢氧化钠,溶于水(4.1)中,稀释至1000ml,溶液存放在聚乙烯瓶内,最长可贮存一周。
4.5盐酸溶液,1+9。
4.6硝酸钾标准溶液。
4.6.1硝酸钾标准贮备液,CN=100mg/L:硝酸钾(KNO3)在105~110℃烘箱中干燥3h,在干燥器中冷却后,称取0.7218g,溶于水(4.1)中,移至1000mL容量瓶中,用水(4.1)稀释至标线在0~10℃暗处保存,或加入1~2mL三氯甲烷保存,可稳定6个月。
4.6.2硝酸钾标准使用液,CN =10mg/L:将贮备液用水(4.1)稀释10倍而得。
使用时配制。
4.7硫酸溶液,1+35。
5、仪器和设备5.1常用实验室仪器和下列仪器。
5.2紫外分光光度计及10mm石英比色皿。
3医用手提式蒸气灭菌器或家用压力锅(压力为1.1~1.4kg/cm2),锅内温度相当于120~124℃。
5.4具玻璃磨口塞比色管,25ml。
所用玻璃器皿可以用盐酸(1+9)或硫酸(1+35)浸泡,清洗后再用水(4.1)冲洗数次。
6、样品6.1采样在水样采集后立即放入冰箱中或低于4℃的条件下保存,但不得超过24h。
水样放置时间较长时,可在1000mL水样中加入约0.5ml硫酸(ρ=1.84g/ml),酸化到PH小于2,并尽快测定。
6.2试样的制备取实验室样品(6.1)用氢氧化钠溶液(4.3)或硫酸溶液(4.7)调节PH 至5~9从而制得试样。
如果试样中不含悬浮物按(7.1.2)步聚测定,试样中含悬浮物则按(7.1.3)步聚测定。
7、分析步聚7.1测定7.1.1用无分度吸管取10.00ml试样(CN超过100μg时,可减少取样量并加水(4。
1)稀释至10ml)置于比色管中。
7.1.2试样不含悬浮物时,按下述步聚进行。
a、加入5ml碱性过硫酸钾溶液(4.4),塞紧磨口塞用布及绳等方法扎紧瓶塞,以防弹出。
b、将比色管置于医用手提出来蒸气灭菌器中,加热,使压力表指针到1.1~1.4kg/cm2,此时温度达到120~124℃后开始计时。
或将比色管置于家用压力锅中,加热至顶压阀吹气时开始计时。
保持此温度加热半小时。
c、冷却,开阀放气,移去外盖,取出比色管并冷至室温。
d、加盐酸(1+9)1ml,用无氨水稀释至25ml标线,混匀。
e、移取部分溶液至10mm,石英比色皿中,在紫外分光光度计上,以无氨水作参比,分别在波长为220与275nm处测定吸光度,并用式(1)计算出校正吸光度A。
7.1.3试样含悬浮物时,先按上述7.1.2中a至d步聚进行,然后待澄清后移取上清液到石英比色皿中。
再按上述7.1.2中e步聚继续进行测定。
7.2空白试验空白试验除以10ml(4.1)代替试料外,采用与测定完全相同的试剂、用量和分析步聚进行平行操作。
注:当测定在接近检测限时,必须控制空白试验的吸光度Ab不超过0.03,超过此值,要检查所用水、试剂、器皿和家用压力锅或医用手提灭菌器的压力。
7.3校准7.3.1校准系列的制备:a、用分度吸管向一组(10支)比色管(5.4)中,分别加入硝酸盐氮标准使用溶液(4.6.2)0.0、0.10、0.30、0.50、0.70、1.00、3.00、5.00、7.00、10.00ml。
加水(4.1)稀释至10.00ml。
b、按7.1.2中a至e步骤进行测定。
7.3.2校准曲线的绘制:零浓度(空白)溶液和其他硝酸钾标准使用溶液(4.6. 2)制得的校准系列完成全部分析步聚,于波长220和275nm处测定吸光度后,分别按下式求出除零浓度外其他校准系列的校正吸光度As和零浓度的校正吸光度Ab及其差值Ar。
As = As220 —2As275 (2)Ab = Ab220 —2Ab275 (3)Ar = As —Ab (4)式中:As220——标准溶液在220nm波长的吸光度;As275——标准溶液在275nm波长的吸光度;Ab220——零浓度(空白)溶液在220nm波长的吸光度;Ab27——零浓度(空白)溶液在275nm波长的吸光度;8、结果的表示8.1计算方法按式(1)计算得试样校正吸光度Ar,在校准曲线上查出相应的总氮μg 数,总氮含量CN(mg/L)按下式计算:mCN = (5)V式中:m——试样测出含氮量,μg;V——测定用试样体积,ml。
水质总磷的测定钼酸铵分光光度法1 主题内容与适用范围本标准规定了用过硫酸钾为氧化剂,将未经过滤的水样消解,用钼酸铵分光光度测定总磷的方法。
总磷包括溶解的、颗粒的、有机的和无机磷。
本标准适用于地面水、污水和工业废水。
2 原理在中性条件下用过硫酸钾使试样消解,将所含磷全部转化为正磷酸盐。
在酸性介质中,正磷酸盐与钼酸铵反应,在锑盐存在下生成磷杂多酸后,立即被抗坏血酸还原,生成蓝色的络合物。
3 仪器及用具3.1 具塞(磨口)比色管:50mL3.2 加热板3.3 刻度吸管:5mL,2mL,1mL3.4 紫外分光光度计3.5 烧杯:1000mL4 试剂本标准所列试剂除磷酸二氢钾为工作基准试剂外,其余均为分析纯,水为蒸馏水。
4.1 过硫酸钾溶液: 50g/L。
将25g过硫酸钾溶于水并稀释至500mL。
4.2 钼酸铵溶液: 26g/L。
称取13g钼酸铵,精确至0.1g。
称取0.35g酒石酸锑钾,精确至0.01g。
溶于在200mL水中,加入300mL硫酸溶液,混匀,冷却后用水稀释至500mL,混匀,存于棕色试剂瓶中(冷藏可保存两个月)。
4.3 抗坏血酸溶液:100g/L。
称取50g抗坏血酸,精确至0.1g。
溶于蒸馏水中,用水稀释至500mL,贮于棕色试剂瓶中(冷藏可稳定几周,如不变色可长时间使用)。
4.4 磷标准贮备溶液:1mg/mL。
溶解磷酸二氢钾(使用前在105℃下干燥2h)1.0967g于蒸馏水中,移入250mL容量瓶中,稀释至刻度,摇匀。
4.5 磷标准工作溶液:10ug/mL。
吸取5mL磷标准储备溶液于500mL容量瓶中,以蒸馏水稀释至刻度,摇匀。
5 分析步骤5.1 空白试样按(5.2)的规定进行空白试验,用水代替试样,并加入与测定时同体积的试剂。
5.2 测定5.2.1 消解吸取5mL混匀水样于50mL具塞比色管中,加入5mL过硫酸钾溶液(4.1),用蒸馏水稀释至25mL,将比色管置于沸水浴中加热30分钟,取出冷却至室温。
5.2.2 发色分别向各份消解液中加入1mL抗坏血酸溶液(4.3),2mL钼酸铵溶液(4.2),用蒸馏水稀释至50mL,充分混合均匀。
5.2.3 分光光度测量室温下放置30分钟后,使用光程为10mm比色皿,在700nm波长下,以蒸馏水为参比液,空白试液调节零点,测定吸光度后,从工作曲线(5.2.4)上查得磷的含量。
5.2.4 工作曲线的绘制取6支具塞比色管分别加入0.0;0.50;1.0;2.0;3.0;4.0mL磷标准溶液(4.5)。
然后按步骤(5.2)进行处理,以蒸馏水为参比液,空白试液调节零点,测定吸光度后,和对应的磷的含量绘制工作曲线。
6 计算总磷含量以C(mg/L)表示,按下式计算:m×XC = --------V式中:m ----试样测得含磷量,ug;X ---样品稀释倍数;V ----测定用试样体积,mL。
注:1、对于总磷较大的水样(如精炼厂、榨油厂污水和中和水)需将水样稀释50倍后再进行检测;排放水采样量为10mL。
2、若消解后的试样有悬浮物需过滤后再发色。