化学品安全技术说明书-MerckMillipore
Merck Millipore 30L-100L水存储胶囊说明书
![Merck Millipore 30L-100L水存储胶囊说明书](https://img.taocdn.com/s3/m/cb85b77615791711cc7931b765ce0508763275a6.png)
Storage Tanks and AccessoriesStorage with a DifferenceMerck Millipore is a business ofGuarantee the purity of your stored waterPure water requires a storage system to prevent the degradation of your water quality. Merck Millipore’s 30-, 60-, and 100-liter polyethylene (PE) storage tanks are designed to maintain consistent purity of stored water and provide effective protection against airborne contaminants.*Prevent contamination Water stagnancy can cause bacterial proliferation. Our optimal Automatic Sanitization Module (ASM) provides the ideal solution for the prevention of bacterial growth and biofilm formation on the inner surface of the storage tank. In addition, our advanced vent filter protects pure water from airborne contamination.Distribute your stored water where it is neededTo provide pure water for use with all of their applications, laboratories need to be able to distribute stored water from their water purification system storage tanks.- For distribution of non-pressurized pure water,conveniently located on the front of the Merck Milliporestorage tanks.- For convenient distribution the storage tank, an E-POD® point-of-delivery dispenser can be connected to an Elix® Advantage or Milli-Q® Integral water purification system.- For automatic feed of pure water, distribution valves on the base of the storage tank allow connection to other laboratory equipment such as glassware washing machines. Distributionpumps are also available if needed.* A complete line of storage tanks is available, ranging in capacity from a few liters to several hundred liters . Your nearest Merck Millipore office will be able to guide you in the choice of the tank best suited to your needs.4562Unique features• Polyethylene selected for its minimum release of extractables • Opaque walls block sunlight to prevent algae development • Smooth inner surface prevents biofilm formation• Cylindrical shape minimizes surface area in contact with water • Conical bottom allows complete draining for cleaning and rinsing • Pure water smoothly fed in at the bottom of the tank prevents absorption of carbon dioxide• Front valve enables manual dispense of pure water• Distribution valves permit connection to other laboratory equipment • Hermetically sealed lid blocks air from entering the tank• Large top opening allows manual cleaning during sanitization procedure • Compact space-saving designFail-safe protection• Sensor rod float switch system for automatic storage tank refill and indication of water level (% full)• Overflow connected to the drain, in the unlikely event of a water system malfunction• Direct display of stored water level on water purification system units • Water sensorMerck Millipore 30-, 60-, and 100-liter polyethylene storage tanks incorporate the latest technical developments and advanced features for stored water of consistent purity.All tanks have a small footprint and are designed for wall-mounting if required. Underbench installation is also possible for some models.For details of the tests performed during the storage tank development process, please request the publication “R &D Notebook 1: Optimizing the storage of purified water for laboratory applications” (Ref. No.: RD001EN00)from your local Merck Millipore representative.Optimized pure water storageInnovative storage tank designStorage tanks designed for efficiencyThe main concern when storing pure water is degradation of water purity over time. Only a strict choice of storage tank materials, associated with a careful design and appropriate protection against airborne contaminants, can ensure consistent water quality during storage.Designed for efficiency1. Hermetically sealed lid2. Sensor rod float switch3. Sanitary overflow4. Blow-molded storage tank5. Cylindrical shape6. Conical bottom with distribution valves7. Front dispensing valve8.Advanced vent filter3Advanced storage tank vent filterStorage Tank AccessoriesIn order to help ensure optimum purity and distribution of your stored water, Merck Millipore offers a range of accessories and connections for your storage tank, including the following items:Advanced vent filter:important protection against airborne contaminantsAir is contaminated by carbon dioxide, particles, microorganisms, and volatile organic compounds that come mainly from the laboratory atmosphere. To protect pure water from all these contaminants, Merck Millipore has developed an advanced storage tank vent filter that includes:• Activated carbon to adsorb volatile organics (including lab solvents such as acetone, chloroform, and methanol)• A soda-lime bed to remove CO 2• A Durapore® hydrophobic membrane for particle and bacteria retentionThis advanced vent filter is recommended for the protection of high-resistivity water, such as Elix® product water, during storage. To protect RiOs™ reverse osmosis-quality water, a Durapore® 0.45 µm hydrophobic membrane vent filter is also available.1. Airborne Contaminants A. Volatile Organics B. Particles C. Bacteria D. CO 22. Volatile Organics absorption3. CO 2 removal4. Particle and Bacterial retention5. Storage tank inletPurified air enters the storage tank• Advanced Vent Filter• Automatic Sanitization Module • Air Gap Device• E-POD® pure water remote dispenser • Washer Distribution Kit • Water Sensor • Lab Close KitComplete Merck Millipore water purification chain with the ASM and water sensor4Automatic Sanitization Module (ASM):say “No!” to bacterial proliferation Maintaining high purity water with low bacteria levels during storage is critical. If left to proliferate, trace levels of microorganisms present in pure water compromise water purity. This bacterial contamination is responsible for the formation of a biofilm — an accumulation of organic material made up of active and dead organisms, on the inner walls of the storage tank.Even though chemical sanitization and mechanical scrubbing may be periodically performed, this biofilm is difficult to remove and is a frequent source of recontamination in stored water.Merck Millipore’s ASM is designed to prevent the growth and proliferation of bacteria and the resulting biofilm on the inner surface of Merck Millipore PE storage tanks. The ASM makes use of the germicidal properties of an ultraviolet (UV) light at 254 nm, which is fitted inside the tank.The ASM provides full flexibility for guaranteed results• 254 nm UV lamp; selected for its germicidal effectiveness • Pre-programmed intervals of 10-min / day automatic UV illumination for optimized efficiency• Additional programmable and manual UV exposure possible to meet critical application requirements• Up to 45 min /day of UV exposure for total flexibility• Program daily time settings, UV cycles, and UV lamp operation displayed on the Millitrack® e-Solution dashboard • UV lamp exchange alarm for easy maintenance• Compact design allowing installation on top of the storage tank10 minutes of daily UV exposure is sufficientDuring development of the ASM, the UV lamp exposure cycles were optimized by examining the resulting bacterial reduction after exposure.Two 60-liter storage tanks were fed by an intentionally contaminated reverse osmosis water purification system. The tanks were then emptied and refilled each day and alternately equipped with an ASM into which variable illumination times were programmed.As shown in the graphs, 10 minutes per day of UV exposure were enough to make the tanks return to their original low bacterial levels.Biofilm formation over timeGermicidal effectiveness of the UV lamp5Air gap device for protection against bacteriological contaminationWater purification systems and storage tanks sometimes require a connection to the drain. Drains are typically dirty environments contaminated by microorganisms, and in particular, bacteria. Therefore, when the outlet of the water system reject tubing is pushed into the drain, there is a risk that bacteria could contaminate the inside of the reject tubing, and then progressively move to the water system.One way to prevent this from occurring is to install an air gap device on the reject tubing. This allows the reject water flow to movethrough the tubing without touching the inside of the contaminateddrain environment. Installing an air gap device is an easy and safe way to prevent the development of bacteria above the air gap level.The E-POD® Elix® water point-of-delivery unit can be connected to an Elix® Advantage pure water system or Milli-Q® Integral pure and ultrapure water system to dispense pure water wherever it is needed in the lab.Advantages of the E-POD® remote dispenser include: • Improved bacterial water quality(less than 0.1 cfu/mL, with final filter)• V ersatility enabling use for multiple applications or users when a Millipak® or Biopak® polisher is fitted to the dispenser outlet• Volumetric dispensing to save time • Ergonomic design and ease of use• Flexibility, with installation of up to three E-POD® units per system• Information at a glance thanks to the color backlit screen on the dispenser base •Space-saving small footprintE-POD® pure water remote dispenserAir Gap DeviceE-POD® pure water remote dispenser: pure water where you need it6Water sensor for control over feed water supplyIf there is water on the floor, the water sensor enables shutdown of the feed water supply in order to prevent a lab flood.Lab Close Kit keeps your system in top condition when you’re away When your facility is closed for an extended time — such as vacation periods — the Lab Close K it will avoid water purification system standstill during these long periods. The Lab Close K it intelligently optimizes the consumption of water and electricity by your system, preventing the negative effects of nonuse, such as bacteria buildup. Your water purification system remains in top condition, ready forimmediate use upon your return.Distribution pumps to meet increased demandsWasher Distribution KitA key use of pure water is as feed to laboratory appliances such as glassware washers, autoclaves, sterilizers and weathering devices.The Merck Millipore Washer Distribution Kit provides cost-effective and convenient distribution of pure water to common laboratory appliances, with flow rates between 12.5 – 13.5 L/min (at 2 bar or 30 psi, depending on voltage).Installation of the small-footprint kit is fast, easy, and universal, with bench, underbench, or wall-mounted options. Users profit from a silent, automatic supply of pure water when required.The graph shows characteristics of Merck Millipore distribution pumps.Pumps provide a long service lifetime and quiet operation.Washer Distribution KitSpecifications & Ordering InformationSpecifications for Polyethylene Storage TanksThere are several different storage tank sizes available in this range:* For 30-liter and 100-liter storage tanks, underbench models are also available.Ordering InformationPolyethylene Storage Tanks7For more information, please visit our website:/labwaterPB5506EN00 Copyright 2015 EMD Millipore Corporation, Billerica, MA., U.S.A.Merck Millipore, the M mark, Milli-Q, Elix, AFS, E-POD, Millitrack, Millipak, Biopak, and Durapore are registered trademarks of, and RiOs is a trademark of, Merck KGaA, Darmstadt, Germany.All rights reserved.。
钙测试预装试剂盒说明书
![钙测试预装试剂盒说明书](https://img.taocdn.com/s3/m/424f22a5162ded630b1c59eef8c75fbfc77d9486.png)
Millipore- 1.00858页码 1 的 9The life science business of Merck operates as MilliporeSigma in the US化学品安全技术说明书按照GB/T 16483、GB/T 17519编制版本6.2修订日期18.09.2022打印日期18.09.2022最初编制日期19.07.2017SDS 编号Millipore - 1.00858产品编号Millipore - 1.00858钙测试预装试剂盒第1部分:化学品及企业标识1.1 产品标识产品名称: 钙测试预装试剂盒Calcium Cell Test Method: photometric 10 -250 mg/l Ca14 - 350 mg/l CaO25 - 624 mg/l CaCO₃ Spectroquant®产品编号: 1.00858产品编号: 100858品牌: Millipore1.2 安全技术说明书提供者的详情制造商或供应商名称: Sigma-Aldrich (Shanghai) Trading Co.Ltd.509 Renqing RoadZhangjiang High Tech East Park, PudongSHANGHAI201201 SHANGHAICHINA西格玛奥德里奇(上海)贸易有限公司上海市浦东新区仁庆路509号10幢邮政编码:201201默克股份两合公司64271 达姆施塔特德国Millipore - 1.00858 页码 2 的 9The life science business of Merck operates as MilliporeSigma in the USPhone:+49(0)6151 72-2440电话号码 : +86 21 6141-5566 传真: +86 21 6141-55671.3 应急咨询电话紧急联系电话: +86 532 838890901.4 物质或混合物的推荐用途和限制用途已确认的各用途 : 分析用试剂这是此产品概括的物质安全资料表(SDS),如需第16项中所列的每一成分完整的物质安全资料表(SDS),请浏览我们的网站.第2部分:危险性概述2.1 GHS 危险性类别易燃液体 (类别 3), H226 金属腐蚀物 (类别 1), H290严重眼睛损伤/眼睛刺激性 (类别 2A ), H319 生殖毒性 (类别 1B ), H360本部分提及的健康说明(H-)全文请见第16部分。
Millipore 超滤管 0.5ml 中文说明书
![Millipore 超滤管 0.5ml 中文说明书](https://img.taocdn.com/s3/m/ddaa729383d049649b6658d4.png)
• Amicon® Ultra 3K 超滤管 — 3,000 NMWL • Amicon® Ultra 10K 超滤管 — 10,000 NMWL • Amicon® Ultra 30K 超滤管 — 30,000 NMWL • Amicon® Ultra 50K 超滤管 — 50,000 NMWL • Amicon® Ultra 100K 超滤管 — 100,000 NMWL
用,则让液体保留在滤膜上,直到使用。
如何使用Amicon® Ultra-0.5超滤离心管
1. 将Amicon® Ultra-0.5超滤内管插入所提供的一个微量离心管中。 2. 向Amicon® Ultra内管中加入不超过500 μL的样本,并盖上盖子。 3. 将盖好盖子的超滤管放入离心转子中,让盖子的连接带朝着转子的中央;用一个类似的超滤管平衡。 4. 以14,000 x g离心约10-30分钟,具体时间取决于所使用超滤管的NMWL。为了确定合适的离心时
≥ 90 ≥ 90 ≥ 95
PCR引物去除率 (%)
≥ 90 ≥ 85 ≥ 75
≥ 90 ≥ 90 ≥ 80
≥ 90 ≥ 90 ≥ 90
≥ 90 ≥ 95 ≥ 95
TE洗涤 (次数)
0 1 2
0 1 2
0 1 2
0 1 2
离心条件:40º固定角度转子,14,000 x g,室温,100 μL PCR样品和400μL TE缓冲液合计起始体积500 μL,20-30 μL终体积,10分钟离心,n = 12。
2
74
7
42
12
完整版)化学品安全技术说明书(MSDS)中英文对照及翻译完整版
![完整版)化学品安全技术说明书(MSDS)中英文对照及翻译完整版](https://img.taocdn.com/s3/m/2b4f2c76ff4733687e21af45b307e87101f6f8db.png)
完整版)化学品安全技术说明书(MSDS)中英文对照及翻译完整版剔除格式错误和明显有问题的段落,改写如下:XX公司XX nMaterial Safety Data ___化学品安全技术说明书SECTION 1: ___化学品及企业标识PRODUCT NAME:产品名CAS NO.:SUPPLIER:供应商:___:企业应急SECTION 2: HAZARDS ___危险性概述2.1 CLASSIFICATION OF ___物质分类This substance is ___(EC) No 1272/2008.根据(EC) No 1272/2008规定此物质不属于危险品。
2.2 LABEL ELEMENTS标记要素The product does not require special ___.此产品不需要按照___法则或各国法规进行特殊标签。
2.3 OTHER HAZARDS – NONE其他危害n ___: drug abuse侵入途径:误服___ HAZARDS健康危害Eye contact: May cause eye ___。
redness。
___.眼接触:可引起眼睛刺激、发红、流泪、视力模糊。
Skin contact: May cause skin ___ contact may cause skin degrease.皮肤接触:可引起皮肤刺激和皮炎。
长时间接触可能导致皮肤脱脂。
Refer to ns 7.8 and 13 for further n on handling。
___ of the product。
Always follow ___ necessary。
6.1 Personal ns。
______ dust and avoid inhaling vapours。
mist or gas。
___ 8.6.2 Environmental nsIf safe to do so。
take ___。
MilliporeSigma LC-Pak 产品说明书
![MilliporeSigma LC-Pak 产品说明书](https://img.taocdn.com/s3/m/ba8ec9a0f605cc1755270722192e453610665bef.png)
Data SheetLC-Pak®LCPAK00A1IntroductionThe LC-Pak® polisher is areverse-phase C18 granularsilica-based cartridge. It has beenvalidated to produce 500 L of watersuitable for trace and ultra-traceorganic analysis, when fed withMilli-Q® ultrapure water.Ultrapure water treated by anLC-Pak® polisher is suitable foreluent, buffer or blank preparation,sample dilution and standardpreparation, as well as columnrinsing in applications such asUHPLC, LC-MS, LC-MS-MS.Instructions are available as aself-guided wizard, directly on theQ-POD® dispenser display of theMilli-Q® IQ 7000. You can accessthem from the Consumables menuor the Maintenance menu.For more information, refer tothe user manual or quick guide.The life science business of Merck operates asMilliporeSigma in the U.S. and Canada.2Note:The flow tip can be located either on your old LC-Pak ® or, if it is a new a installation, it is provided with the Application-Pak installation kit (EDSKIT001).1. Remove the new LC-Pak ® from the package.2. Remove and discard the caps at the inlet and outlet of the cartridge.3. Install the flow tip at the outlet.Step 21. Syringe adapter2. Clean glass Luer slip tip syringe (50 mL) *3. 50 mL of high grade methanol *Required material for LC-Pak ® conditioning:Step 1Conditioning• The LC-Pak ® polisher is manufactured, packed and shipped dry.• Prior to installation, it is necessary to condition its reverse-phase silica with high grade methanol (99.9+%).W ear eye safety glasses, laboratory gloves and other appropriate safety equipment when working with methanol.* Purchased separately.23• T wist the new LC-Pak ® into place.Flush the cartridge with ultrapure water for at least 10 minutes.• T he LC-Pak ® installation is now complete. You can dispense ultrapure water from the cartridge for your application.• R emove the expired Application POD-Pak if any.Step 4Step 5Step 6Step 7Installation• The LC-Pak ® cartridge has a Luer female inlet connection designed for direct connection to the outlet of Q-POD ® remote dispenser of Milli-Q ®IQ 7000 system.1. Press the dispenser wheel to start rinsing.2. After 10 minutes (at least 20 L) of rinsing, press the dispenser wheel again to complete the installation.Your LC-Pak ® certificate of quality is available onLit. No. DS5434ENEU Ver. 1.02017 - 0634701/2018OperationEvery day, discard the first liter of water produced by the water purification system to minimize environmental contamination from the water outlet.Multiple applicationsIf water dispensed requires bacteria levels below 0.1 CFU/mL and particles < 0.22 μm, you can adapt a Millipak ® filter after the LC-Pak ® cartridge using the connector provided in the installation and conditioning kit (EDSKIT001).Water purified through this cartridge may not be suitable for other applications.For your Milli-Q ® water to match several applications, you may connect up to 4 Q-POD ® remote dispensers to your Milli-Q ® production unit. Install your LC-Pak ® at the outlet of one Q-POD ® dispenser and select amongst our range of POD-Paks the suitable ones for your other applications (visit )MaintenanceValidation tests performed in our laboratories have demonstrated that, once conditioned, the LC-Pak ® cartridge can deliver ultrapure water suitable for UHPLC, LC-MS, LC-MS-MS applications for at least 500 liters when fed by ultrapure water from a Milli-Q ® IQ 7000 water purification system.Feed waterResistivity 18.2 MΩ.cm @ 25°C and TOC < 5 ppb Inlet connectionLuer female Water temperature5 – 30°C Cartridge lifetime 500 litersHousingPolypropylene ConnectorPolyethylene Purification mediaReverse-phase silica beads Sintered filterPolypropylene Reverse-phase silica compression disc PolypropyleneDescriptionCat. No.LC-Pak ® polisherLCPAK00A1Application-Pak Installation Kit EDSKIT001© 2018 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved. Merck, the vibrant M, LC-Pak, Milli-Q, Millipak and Q-POD are trademarks of Merck KGaA, Darmstadt, Germany and/or its affiliates. All other trademarks are the property of their respective owners. Detailed information on trademarks is available via publicly accessible resources.Merck KGaA Frankfurter Strasse 250, 64293 Darmstadt, Germany。
Merck铝测试盒补充液说明书
![Merck铝测试盒补充液说明书](https://img.taocdn.com/s3/m/1706464f78563c1ec5da50e2524de518974bd352.png)
化学品安全技术说明书按照 GB/T 16483、GB/T 17519 编制修订日期 15.01.2021版本 11.15页码 1 的 25第1部分:化学品及企业标识 产品标识 SDS 编号 114825 产品编号 114825产品名称铝测试盒 (补充液) Method: photometric 0.020 - 1.20 mg/l Al Spectroquant ®组分Al-1安全技术说明书提供者的详情制造商或供应商名称 默克股份两合公司, 64271 达姆施塔特, 德国 * Phone:+49 6151 72-0 责任部门化学事故应急咨询电话物质或混合物的推荐用途和限制用途 已确认的各用途 分析用试剂欲了解有关用途的更多信息,请参考Merck Chemicals 门户网站。
第2部分:危险性概述 紧急情况概述固体 灰白色或米色 无臭 吸入之后:新鲜空气. 在皮肤接触的情况下: 立即除去∕脱掉所有沾污的衣物。
用水清洗皮肤/淋浴。
眼睛接触之后:以大量清水洗去., 取下隐形眼镜。
吞食之后:立即饮水(最多 2 杯). 如感不适,请就医. 具有可燃成分的混合物。
着火可能演变出: 硫氧化物 起火时可能引发产生危害性气体或蒸气. 可能与之发生剧烈反应: 强氧化剂2.1 GHS 危险性分类产品名称组分铝测试盒 (补充液) Method: photometric 0.020 - 1.20 mg/l Al Spectroquant®Al-1页码 2 的 25非危险物质或混合物。
标签要素GHS标签非危险物质或混合物。
物理和化学危险目前掌握信息,没有物理或化学的危险性。
健康危害目前掌握信息,没有健康危害。
环境危害目前掌握信息,没有环境的危害。
其它危害健康危害环境危害未见报道。
第3部分:成分/组成信息化学性质有机物与无机物的混合物.物质不适用混合物本部分提及的健康说明(H-)全文请见第16部分。
(完整版)化学品安全技术说明书(MSDS)中英文对照及翻译完整版
![(完整版)化学品安全技术说明书(MSDS)中英文对照及翻译完整版](https://img.taocdn.com/s3/m/3155828d69eae009591bec26.png)
XX 公司XX Corporation Material Safety Data Sheet 化学品安全技术说明书SECTION 1: PRODUCT AND COMPANY IDENTIFICATION 化学品及企业标识PRODUCT NAME: 产品名CAS NO.: SUPPLIER: 供应商:企业应急电话:Emergency TelephoneSECTION 2: Hazards identification 危险性概述无毒:2.1 Classification of the substance or mixture 物质分类Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008 据(EC) No1272/2008规定不属于有害物质This substance is not classified as dangerous according to Directive 67/548/EEC. 根据67/548/EEC 号文件此物质不属于危险品2.2 Label elements 标记要素The product does not need to be labelled in accordance with EC directives or respective national laws.此产品不需要按照欧共体法则或各国法规进行特殊标签2.3 Other hazards –none 其他危害有毒:In-taking Pathways: drug abuse, skin or eyes contact 侵入途径:吸入、皮肤、眼、误服Health hazards 健康危害Eye contact: May cause eye irritation, redness, tearing or blurred vision 眼接触:可引起眼睛刺激、发红、流泪、视力模糊。
氢氧化镁安全技术说明书英文
![氢氧化镁安全技术说明书英文](https://img.taocdn.com/s3/m/e133dd50daef5ef7bb0d3c86.png)
SAFETY DATA SHEETSAccording to Globally Harmonized System of Classification andLabelling of Chemicals (GHS) - Sixth revised edition1.Identification1.1GHS Product identifierProduct name MAGNESIUM HYDROXIDE1.2Other means of identificationProduct number-Other names MAGGRAN(R) MH1.3Recommended use of the chemical and restrictions on useIdentified uses For industry use only.Uses advised against no data available1.4Supplier's detailsCompanyAddressTelephoneFax1.5Emergency phone numberEmergency phone numberService hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMThours).2.1Classification of the substance or mixtureno data available2.2GHS label elements, including precautionary statementsPictogram(s)no data availableSignal word no data availableHazard statement(s)no data availablePrecautionarystatement(s)Prevention no data availableResponse no data availableStorage no data availableDisposal no data available2.3Other hazards which do not result in classificationno data available3.1Substances4.1Description of necessary first-aid measuresGeneral adviceConsult a physician. Show this safety data sheet to the doctor in attendance.If inhaledIf breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.In case of skin contactWash off with soap and plenty of water. Consult a physician.In case of eye contactRinse thoroughly with plenty of water for at least 15 minutes and consult a physician.If swallowedNever give anything by mouth to an unconscious person. Rinse mouth with water. Consult aphysician.4.2Most important symptoms/effects, acute and delayedno data available4.3Indication of immediate medical attention and special treatment needed, if necessaryno data available5.1Extinguishing mediaSuitable extinguishing mediaUse water spray, alcohol-resistant foam, dry chemical or carbon dioxide.5.2Specific hazards arising from the chemicalno data available5.3Special protective actions for fire-fightersWear self-contained breathing apparatus for firefighting if necessary.6.1Personal precautions, protective equipment and emergency proceduresUse personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas.Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. Forpersonal protection see section 8.6.2Environmental precautionsPrevent further leakage or spillage if safe to do so. Do not let product enter drains. Dischargeinto the environment must be avoided.6.3Methods and materials for containment and cleaning upPick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers fordisposal.7.1Precautions for safe handlingAvoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure -obtain special instructions before use.Provide appropriate exhaust ventilation at places wheredust is formed. For precautions see section 2.2.7.2Conditions for safe storage, including any incompatibilitiesStore in cool place. Keep container tightly closed in a dry and well-ventilated place.8.1Control parametersOccupational Exposure limit valuesno data availableBiological limit valuesno data available8.2Appropriate engineering controlsHandle in accordance with good industrial hygiene and safety practice. Wash hands beforebreaks and at the end of workday.8.3Individual protection measures, such as personal protective equipment (PPE)Eye/face protectionSafety glasses with side-shields conforming to EN166. Use equipment for eye protection testedand approved under appropriate government standards such as NIOSH (US) or EN 166(EU).Skin protectionWear impervious clothing. The type of protective equipment must be selected according to theconcentration and amount of the dangerous substance at the specific workplace. Handle withgloves. Gloves must be inspected prior to use. Use proper glove removal technique(withouttouching glove's outer surface) to avoid skin contact with this product. Dispose of contaminatedgloves after use in accordance with applicable laws and good laboratory practices. Wash anddry hands. The selected protective gloves have to satisfy the specifications of EU Directive89/686/EEC and the standard EN 374 derived from it.Respiratory protectionWear dust mask when handling large quantities.Thermal hazardsno data availablePhysical state powderColour no data availableOdour no data availableMelting point/ freezing350ºC(lit.)pointno data availableBoiling point or initialboiling point and boilingrangeFlammability no data availableno data availableLower and upper explosionlimit / flammabilitylimitFlash point no data availableno data availableAuto-ignitiontemperatureDecompositionno data availabletemperaturepH no data availableKinematic viscosity no data availableSolubility no data availablePartition coefficientno data available n-octanol/water (logvalue)Vapour pressure no data availableno data available Density and/or relativedensityRelative vapour density no data availableParticle characteristics n o data available10.1Reactivityno data available10.2Chemical stabilityStable under recommended storage conditions.10.3Possibility of hazardous reactionsno data available10.4Conditions to avoidno data available10.5Incompatible materialsno data available10.6Hazardous decomposition productsno data availableAcute toxicity•Oral: no data available•Inhalation: no data available•Dermal: no data availableSkin corrosion/irritationno data availableSerious eye damage/irritationno data availableRespiratory or skin sensitizationno data availableGerm cell mutagenicityno data availableCarcinogenicityno data availableReproductive toxicityno data availableSTOT-single exposureno data availableSTOT-repeated exposureno data availableAspiration hazardno data available12.1Toxicity•Toxicity to fish: no data available•Toxicity to daphnia and other aquatic invertebrates: no data available•Toxicity to algae: no data available•Toxicity to microorganisms: no data available12.2Persistence and degradabilityno data available12.3Bioaccumulative potentialno data available12.4Mobility in soilno data available12.5Other adverse effectsno data available13.1Disposal methodsProductThe material can be disposed of by removal to a licensed chemical destruction plant or bycontrolled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.Contaminated packagingContainers can be triply rinsed (or equivalent) and offered for recycling or reconditioning.Alternatively, the packaging can be punctured to make it unusable for other purposes and thenbe disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possiblefor combustible packaging materials.14.1UN NumberADR/RID: no data available IMDG: no data available IATA: no data available 14.2UN Proper Shipping NameADR/RID: no data availableIMDG: no data availableIATA: no data available14.3Transport hazard class(es)ADR/RID: no data available IMDG: no data available IATA: no data available 14.4Packing group, if applicableADR/RID: no data available IMDG: no data available IATA: no data available 14.5Environmental hazardsADR/RID: no IMDG: no IATA: no14.6Special precautions for userno data available14.7Transport in bulk according to Annex II of MARPOL 73/78 andthe IBC Codeno data available15.1Safety, health and environmental regulations specific for theproduct in questionInformation on revisionCreation Date Aug 19, 2017Revision Date Aug 19, 2017Abbreviations and acronyms•CAS: Chemical Abstracts Service•ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road •RID: Regulation concerning the International Carriage of Dangerous Goods by Rail •IMDG: International Maritime Dangerous Goods•IATA: International Air Transportation Association•TWA: Time Weighted Average•STEL: Short term exposure limit•LC50: Lethal Concentration 50%•LD50: Lethal Dose 50%•EC50: Effective Concentration 50%Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.。
利特莫韦液体制剂化学品安全技术说明书
![利特莫韦液体制剂化学品安全技术说明书](https://img.taocdn.com/s3/m/83d507fa970590c69ec3d5bbfd0a79563d1ed411.png)
版本1.19修订日期:2023/04/04SDS编号:66855-00020前次修订日期: 2022/10/01最初编制日期: 2015/02/271. 化学品及企业标识产品名称: Letermovir Liquid Formulation制造商或供应商信息制造商或供应商名称: MSD地址: 199 Wenhai North RoadHEDA, Hangzhou - Zhejiang Province - CHINA310018电话号码: 908-740-4000应急咨询电话: 86-571-87268110电子邮件地址: **********************推荐用途和限制用途推荐用途: 制药的限制用途:不适用2. 危险性概述紧急情况概述外观与性状: 液体颜色: 澄清气味: 无臭非危险物质或混合物。
GHS危险性类别非危险物质或混合物。
GHS标签要素无需危险象形图、信号词、危险性说明及防范说明。
物理和化学危险根据现有信息无需进行分类。
健康危害根据现有信息无需进行分类。
环境危害根据现有信息无需进行分类。
版本1.19修订日期:2023/04/04SDS编号:66855-00020前次修订日期: 2022/10/01最初编制日期: 2015/02/27GHS未包括的其他危害未见报道。
3. 成分/组成信息物质/混合物: 混合物组分化学品名称化学文摘登记号(CAS No.)浓度或浓度范围 (% w/w) Letermovir917389-32-3>=1 - <2.54. 急救措施一般的建议: 出事故或感觉不适时,立即就医。
在症状持续或有担心,就医。
吸入: 如吸入,移至新鲜空气处。
就医。
皮肤接触: 如接触,立即用肥皂和大量水冲洗皮肤。
脱去被污染的衣服和鞋。
就医。
重新使用前要清洗衣服。
重新使用前彻底清洗鞋。
眼睛接触: 谨慎起见用水冲洗眼睛。
如果刺激发生并持续,就医。
食入: 如吞咽:不要引吐。
化学品安全技术说明书(MSDS)中英文对照及翻译完整版
![化学品安全技术说明书(MSDS)中英文对照及翻译完整版](https://img.taocdn.com/s3/m/3cc80260be23482fb4da4c4e.png)
化学品安全技术说明书(MSDS)中英文对照及翻译完整版各位读友大家好,此文档由网络收集而来,欢迎您下载,谢谢篇一:化学品安全技术说明MSDS-亚硫酸氢钠(中英文对照版本)Sodium Bisulfite1) Chemical Product and Company IdentificationMSDS Name: Sodium Sulfite, AnhydrousCatalog Numbers: S80195, 1MSS44-20, 1MSS4420, BP355 500, BP355-500, BP355500, S430 10, S430 3, S430 500, S430-10, S430-3, S430-500, S43010, S4303, S430500, S447 3, S447 500, S447-3, S447-500, S4473, S447500 Synonyms: Sulfurous acid, disodium saltRisk Phrases: 22 36/37/383) Hazards IdentificationEMERGENCY OVERVIEWAppearance: white. Air sensitive. Moisture sensitive. Warning! Causes eye and skin irritation. May cause digestive tract irritation. Causes respiratory tract irritation. May be harmful if swallowed.Target Organs: Central nervous system.Potential Health EffectsEye: Causes eye irritation. May cause chemical conjunctivitis.Skin: Causes skin irritation.Ingestion: May cause gastrointestinal irritation with nausea, vomiting and diarrhea. May be harmful if swallowed.Inhalation: Causes respiratory tract irritation. Can produce delayed pulmonary edema.Chronic: Effects may be delayed.4) First Aid MeasuresEyes: Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.Skin: Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.Ingestion: If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.Inhalation: Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid. Notes to Physician: Treat symptomatically and supportively.5) Fire Fighting MeasuresGeneral Information: As in any fire,wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Wear appropriate protective clothing to prevent contact with skin and eyes. Wear a self-contained breathing apparatus (SCBA) to prevent contact with thermal decomposition products.Extinguishing Media: Substance is noncombustible; use agent most appropriate to extinguish surrounding fire. Do NOT get water inside containers. Use water spray, dry chemical, carbon dioxide, or appropriate foam.6) Accidental Release MeasuresGeneral Information: Use proper personal protective equipment as indicated in Section 8.Spills/Leaks: Vacuum or sweep upmaterial and place into a suitable disposal container. Clean up spills immediately, observing precautions in the Protective Equipment section. Avoid generating dusty conditions. Provide ventilation. Place under an inert atmosphere. Do not get water inside containers.7) Handling and StorageHandling: Wash thoroughly after handling. Use with adequate ventilation. Minimize dust generation and accumulation. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Handle under an inert atmosphere. Store protected from air. Do not allow contact with water. Wash clothing before reuse. Keep from contact with moist air and steam.Storage: Store in a tightly closed container. Keep from contact with oxidizing materials. Store in a cool, dry,well-ventilated area away from incompatible substances. Keep away from strong acids. Do not expose to air. Store protected from moisture. Store under an inert atmosphere.8) Exposure Controls, Personal ProtectionEngineering Controls: Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate ventilation to keep airborne concentrations low.listed for this chemical.Personal Protective EquipmentEyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA’s eye and face protection regulations in 29 CFR or European Standard EN166.Skin: Wear appropriate protective gloves to prevent skin exposure.Clothing: Wear appropriate protectiveclothing to prevent skin exposure.Respirators: A respiratory protection program that meets OSHA’s 29 CFR and ANSI requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator’s use. Follow the OSHA respirator regulations found in 29CFR or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.9) Physical and Chemical PropertiesPhysical State: SolidAppearance: whiteOdor: odorlesspH: Not available.Vapor Pressure: Not available.Vapor Density: Not available.Evaporation Rate: Not available.Viscosity: Not available.Boiling Point: Not available.Freezing/Melting Point: Notavailable.Autoignition Temperature: Not available.Flash Point: Not available.Decomposition Temperature: > 500 deg CNFPA Rating: (estimated) Health: 2; Flammability: 0; Reactivity: 0Explosion Limits, Lower: Not available.Upper: Not available.Solubility: 23 g/100 mL water (20°C)Specific Gravity/Density: /cm3Molecular Formula: Na2O3SMolecular Weight:10) Stability and ReactivityChemical Stability: Stable at room temperature in closed containers under normal storage and handling conditions.Conditions to Avoid: Incompatible materials, dust generation, moisture,exposure to air, excess heat.Incompatibilities with Other Materials: Strong oxidizing agents, acids, organics, moisture, air, combustible materials.Hazardous Decomposition Products: Oxides of sulfur.Hazardous Polymerization: Has not been reported.11) Toxicological InformationRTECS#:CAS# 7757-83-7: WE2150000LD50/LC50:CAS# 7757-83-7:Oral, mouse: LD50 = 820 mg/kg;Carcinogenicity:CAS# 7757-83-7: Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.Epidemiology: No information available.Teratogenicity: No information available.Reproductive Effects: No information available.Neurotoxicity: No information available.Mutagenicity: No information available.Other Studies: No data available.12) Ecological InformationEcotoxicity: No data available. No information available.Environmental: No information found.Physical: No information found.Other: No information available.13) Disposal ConsiderationsChemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts Additionally, waste generators must consult state and local hazardous wasteregulations to ensure complete and accurate classification. RCRA P-Series: None listed.RCRA U-Series: None listed.US FEDERALTSCACAS# 7757-83-7 is listed on the TSCA inventory.Health & Safety Reporting ListNone of the chemicals are on the Health & Safety Reporting List.Chemical Test RulesNone of the chemicals in this product are under a Chemical Test Rule.Section 12bNone of the chemicals are listed under TSCA Section 12b.TSCA Significant New Use RuleNone of the chemicals in this material have a SNUR under TSCA.SARASection 302 (RQ)None of the chemicals in this material have an RQ.Section 302 (TPQ)None of the chemicals in this product have a TPQ.SARA CodesCAS # 7757-83-7: acute.Section 313No chemicals are reportable under Section 313.Clean Air Act:This material does not contain any hazardous air pollutants. This material does not contain any Class 1 Ozone depletors. This material does not contain any Class 2Ozone depletors.Clean Water Act:None of the chemicals in this product are listed as Hazardous Substances under the CW A. None of the chemicals in this product are listed as Priority Pollutantsunder the CWA. None of the chemicals in this product are listed as Toxic Pollutants under the CWA.OSHA:None of the chemicals in this product are considered highly hazardous by OSHA. STATECAS# 7757-83-7 is not present on state lists from CA, PA, MN, MA, FL, or NJ.California No Significant Risk Level: None of the chemicals in this product are listed. European/International Regulations European Labeling in Accordance with EC DirectivesHazard Symbols:XNRisk Phrases:R 22 Harmful if swallowed.R 36/37/38 Irritating to eyes, respiratory systemand skin.Safety Phrases:S 24/25 Avoid contact with skin and eyes.WGK (Water Danger/Protection)CAS# 7757-83-7: 1CanadaCAS# 7757-83-7 is listed on Canada’s DSL List. CAS# 7757-83-7 is listed on Canada’s DSL List.This product has a WHMIS classification of D2B.CAS# 7757-83-7 is not listed on Canada’s Ingredient Disclosure List.Exposure Limits16) Additional InformationMSDS Creation Date: 7/15/1999Revision #1 Date: 8/02/2000The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty,express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall Fisher be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Fisher has been advised of the possibility of such damages.亚硫酸氢钠1)化学品名称化学品中文名称:亚硫酸氢钠化学品英文名称:sodium bisulfite篇二:化学品安全技术说明书(MSDS)篇三:详细化学品安全技术说明书(MSDS)化学品安全技术说明书二〇〇六年二月目录表1-001 乙炔气............ 1 表1-002 表1-003 表1-004 表1-005 表1-006 表1-007 表1-008 表1-009 表1-010 表1-011 表1-012 表1-013 氧气.............. 二氧化碳......... 氢气............. 氩气............. 甲烷............. 四氢噻吩......... 活性炭........... 三乙胺........... 硫代磷酰氯....... 硫黄............ 甲胺磷........... 多聚甲醛........ 5 11 13 15 17 19 21 23 25 27 30 32表1-014(附表1-3)甲缩醛34 表1-015 黄磷............ 36 表1-016 氯.............. 38 表1-017 表1-018 表1-019 表1-020 表1-021 表1-022 表1-023 表1-024 表1-025 表1-026 表1-027 表1-028 三氯化磷......... 甲醇............. 液碱............. 氨水............. 硫酸二甲酯....... 甲胺磷........... 液氨............. 氯仿............. 二氯乙烷......... 二硫化碳......... 甲苯............. 盐酸............. 41 45 47 49 52 54 57 59 61 64 66 68表1-029 氯甲烷........... 71 表1-030 硫酸............. 73 表1-031 二甲苯........... 76 表1-032 表1-033 表1-034 表1-035 表1-036 表1-037 表1-038 表1-039 表1-040 表1-041 表1-042 表1-043 醋酸酐........... 多聚甲醛......... 草甘膦........... 稻瘟灵........... 异丙胺........... 漂白粉........... 氯化氢........... 氰化氢........... 氰化钠........... 氯乙酸........... 甲缩醛........... 丙烯腈..........78 81 82 84 86 88 90 93 95 97 99 102《化学品安全技术说明书(MSDS)中英文对照及翻译完整版》各位读友大家好,此文档由网络收集而来,欢迎您下载,谢谢。
安全技术说明书-ThermoFisherScientific
![安全技术说明书-ThermoFisherScientific](https://img.taocdn.com/s3/m/3fa8aa956529647d272852c7.png)
2017-Mar-23 451002
页码 1 / 11 产品名称 Plant RNA Reagent
CHEMTREC China CHEMTREC Hong Kong (Hong Kong) CHEMTREC Singapore CHEMTREC Singapore CHEMTREC Taiwan
危害说明 H302-吞咽有害 H311-皮肤接触会中毒 H315-造成皮肤刺激 H317-可能引起皮肤过敏反应 H318-引起严重眼损伤 H332-吸入有害 H373-若长期或反复吸入暴露可能对器官造成损伤 H401-对水生生物有毒 H411-对水生生物有毒,且具有长期持续影响
安全技术说明书
________________________________________________________________________________________________________
第 1部分: 化学品及企业标识
物质或混合物标识
产品代码 产品名称
451002 Plant RNA Reagent
Exposure, or Accident. Call CHEMTREC
Outside the USA + Canada: +1 703-741-5970
Country specific Emergency Number (if available):
修订日期 产品代码
________________________________________________________________________________________________________
页码 4 / 11 产品名称 Plant RNA Reagent
微科 无水清洗笔 安全技术说明书
![微科 无水清洗笔 安全技术说明书](https://img.taocdn.com/s3/m/a82658ae162ded630b1c59eef8c75fbfc67d9476.png)
化学品安全技术说明书No-Clean Flux Remover Pen符合GB/T 16483-2008和GB/T 17519-2013规定化学品标识产品名称No-Clean Flux Remover Pen产品编号MCC-DC1PEN化学品的推荐用途和限制用途推荐用途清洗剂。
供应商的详细情况供应商MICROCARE ASIA PTE LTD102E, Pasir Panjang Road,Citilink, #05-06,Singapore 118529(65)6271.0182制造商MICROCARE LLC595 John Downey DriveNew Britain, CT 06051United States of AmericaCAGE: OATV9Tel: +1 800-638-0125, +1 860-827-0626应急咨询电话应急咨询电话INFOTRAC 4001-200761 (CHINA)1-352-323-3500 (from anywhere in the world)紧急情况概述外观液体。
颜色透明液体。
无色的。
气味轻微的。
乙醚。
GHS 危险性类别物理危险易燃液体 类别2健康危害非此类环境危害危害水生环境 一急性危险 类别1健康危害若此品溅射到眼睛,会引起红斑和眼睛过激。
存放在儿童够不着的地方。
请参见第11部分以了解关于健康危害的更多信息。
物理危险产品高度易燃。
蒸气可能会与空气形成爆炸性混合物。
标签要素象形图警示词危险危险性说明H225 高度易燃液体和蒸气。
H400 对水生生物毒性极大。
防范说明预防措施P210 远离热源/ 热表面/ 火花/明火/ 其他点火源。
禁止吸烟。
P240 容器和接收设备接地/ 等势联接。
P242 只能使用不产生火花的工具。
P243 采取防止静电放电的措施。
P273 避免释放到环境中。
事故响应P370+P378 火灾时:使用泡沫、二氧化碳、干粉或水雾灭火。
Merck Millipore Direct-Q 水纯化系统用户指南说明书
![Merck Millipore Direct-Q 水纯化系统用户指南说明书](https://img.taocdn.com/s3/m/9445fea99a89680203d8ce2f0066f5335b81677b.png)
Tap to pure and ultrapure water ― with easy and convenient dispense!Your water purification needs Our solution: the Direct-Q® range of water purification systemsHigh quality water produced directly from tap water Direct-Q® systems deliver both pure and ultra-pure water directly from tap for use with a wide variety of applications in your lab.Ultrapure water easily accessible wherever you need it in your lab With the Direct-Q® range of water purification systems, you benefit from a choice of ultrapure water dispensing possibilities. The innovative, space-saving Remote dispenser offers you water delivery solutions to best fit the way you work, with easy and convenient remote delivery up to two meters away from your water production unit.Compact all-in-one system for the most efficient use of your lab space The Direct-Q® range includes versatile solutions that can be bench-integrated or bench- / wall-installed.A choice of adequate storage volumes Direct-Q® systems come either with an integra-ted 6-liter reservoir or an external reservoir (30 l or 60 l).Flow rates adapted to your daily usage Systems in the Direct-Q® range provide 3, 5 or 8 liters of pure water per hour, covering lab needs of 50,100 and 150 l of pure water per day.Instant flow rates to match your needs Direct-Q® systems dispense up to 30 l ofultrapure water per hour.High quality water to meet the requirements of your most critical applications Options such as a UV lamp and a range of Application Pak point-of-use polishers are available to fine-tune your ultrapure water.Easily accessible information on system operation The user-friendly display provides system status at a glance; the concise Quick Reference Guide is a handy guide for daily operation.Simple, low-level self-maintenance All-in-one SmartPak®cartridges enable easy and rapid replacement.Direct-Q® Systems Water Purification Pathway Choose the solution that’s right for youEasy installationThe Direct-Q® range of systems requires no special installation. You can easily set the system up yourself: just connect the system to your tap water supply, plug it in, and insert the SmartPak® purification cartridges. Then, if your configuration includes the Remote dispenser or a 30- or 60-liter reservoir, follow the simple setup procedures ― and your system is ready to use!Optimized lab spaceThe compact, all-in-one Direct-Q® water purification unit lets you locate it nearly anywhere in your laboratory, either on or under the benchtop, or wall-installed.**Direct-Q® 5 and Direct-Q® 8 systems are designed for use with a 30 l or 60 l external reservoir.Organic-sensitive applicationsDirect-Q® systems are also available with a built-in 185/254 nm UV lamp to reduce the level of organics for critical applications. Water with low TOC provides important benefits to HPLC users such as higher sensiti-vity and longer column lifetime. The same UV lamp also destroys bacteria.Application Pak point-of-use polishersMerck Millipore’s range of Application Pak polishers makes it possible to fine-tune your ultrapure water quality to match your research needs. Are your applications sensitive to bacteria, particulates, pyrogens, nucleases, endocrine disruptors or Volatile Organic Compounds? If so, just choose the appropriate final polisher from our range of Application Paks to provide optimal water quality for your requirements.Please see /labwater for more information.Both pure and ultrapure waterThe Direct-Q® range of systems provides you with a convenient and flexible solution for your pure and ultrapure water needs, directly from potable tap water. You’ll have access to ultrapure water for your critical applications, and pure water for less critical applications such as general glassware washing or final rinsing ― from the same system!The high quality ultrapure water produced by Direct-Q® systems is suitable for applications such as production of mobile phase for chromatographic separations; preparation of blanks and standard solutions for spectrophotometry, spectroscopy or other analytical techniques; and preparation of buffers for biochemical experiments.Flow rates to match your requirementsChoose the solution that best meets your lab’s requirements with a Direct-Q®system that provides 3, 5, or 8 liters of pure water per hour, and more than 0.5 l of ultrapure water per minute (> 30 l per hour). When not in use, the Direct-Q® system automatically recirculates water in order to maintain high water quality,so that you do not have to wait when sourcing ultrapure water. For your conve-nience, and to save time, you can also set the system to automatically deliver your selected volume of ultrapure water on demand.Choice of storage volumesWith its built-in reservoir, the Direct-Q® 3 system can store 6 l of reverse osmosis (RO) water, while Direct-Q® 5 and 8 models are designed for use with a 30- or 60-liter reservoir. Just choose the storage volume that best meets yourdaily water volume needs.Fine-tune your water qualityVersatile remote dispenserDesigned to fit perfectly into your lab environment, the versatile Remote dispenser can be placed up to two meters from your Direct-Q® water purification unit. Select the free-standing or wall-installed model according to your needs ― their ergonomy will make either one a welcome addition to your lab,giving you the freedom to focus on your research, while dispensing ultrapure water exactly where you need it. Alternatively, Direct-Q® systems are also available with an integrated dispenser for use on the benchtop.The design of the bench-installed Direct-Q® systems is also adapted to the height and shape of common laboratory glassware.Stay focused on your workMerck Millipore offers more than waterJust the information you needThe intuitive color graphic display shows key system parameters at a glance,enabling easy water quality and maintenance warnings monitoring; the screen rotates for easy viewing wherever thesystem is located. A short Quick Reference Guide is conveniently located in the base of the system for immediate information; the complete User Manual can be stored at the back of the water purification unit.User-friendly maintenanceThe all-in-one SmartPak® purification cartridges are easily replaced in just a few minutes.Watercare Pact Service portfolioTo optimize the performance and lifetime of your water purification system,Merck Millipore offers a complete portfolio of Service plans ranging from a single annual checkup to a full system cover. For more information, please check with your Merck Millipore applications specialist or visit our website:/labwaterSpecificationsAvailable System ConfigurationsWater Purification Systems* 30 l or 60 l depending on daily water usageFor more information, please visit our website:/directq358Millipore, Direct-Q®, SmartPak®, Millipak® and BioPak® are registered trademarks of Millipore Corporation. Merck Millipore and the M mark are trademarks of Merck KGaA.Lit. No. PB2040EN00© 2011 Millipore Corporation, Billerica, MA, U.S.A. All rights reserved.。
LF2100 - 化学品安全技术说明书 - International Products Corpo
![LF2100 - 化学品安全技术说明书 - International Products Corpo](https://img.taocdn.com/s3/m/5e55838788eb172ded630b1c59eef8c75fbf9591.png)
1.1产品识标注册名称LF2100®1.2物质与混合物相关识别使用以及不建议使用相关识别用途万用清洁剂临时橡胶组件润滑剂工业用途不可做为个人用途(家用)1.3安全数据表供货商详细信息International Products Corporation 201 Connecticut Drive Burlington NJ 08016美国电话: +1 (609) 386-8770传真: +1 (609) 386-8438电邮:*************网站: https:///1.3.1额外信息1.4紧急电话号码1.4.1紧急信息服务+1 (609) 386-8770此号码仅下列办公时间可用: 周一至周五 08:00 - 16:30,Eastern Time第2部分 危险性概述2.1物质或混合物之分类依据 GHS 分类缩写全文:参阅第 16 节.临时橡胶润滑凝胶液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.2022最重要之不良物理化学、人体健康与环境影响短期或长期暴露后可预期迟发性或立即影响.2.2标示组件标示- 讯号字警告- 图示GHS07, GHS082.3其他危害PBT 与 vPvB 评估此混合物不含任何评估为 PBT 或 vPvB 之物质.液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.2022第3部分 成分/组成信息3.1物质不相关(混合物)3.2混合物混合物说明第4部分 急救措施4.1急救措施说明一般注意事项受感染人员不可无人看管. 将患者移出危险区域. 保持受感染人员温暖、静止并覆盖. 立刻脱下所有沾染的衣物. 若有任何疑虑或症状持续,寻求医疗协助. 若昏迷将人员置于复苏姿势。
不可喂食任何物品.吸入之后若呼吸不顺或停止,立即寻求医疗协助并开始急救措施. 提供新鲜空气.皮肤接触之后以大量肥皂与清水冲洗.眼睛接触之后若佩戴隐型眼镜并方便取下,取下隐形眼镜,将眼睑撑开,以大量水持续冲洗至少10分钟.摄入之后以清水冲洗口腔(仅在意识清醒时). 不可诱导呕吐.4.2最重要之症状与作用,急性与迟发症状及影响目前未知.液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.20224.3表示需要任何立即医疗措施与特殊处理无第5部分 消防措施5.1灭火剂适当灭火剂浇水, BC-灭火粉, 二氧化碳 (CO2)不适当灭火剂水柱5.2物质或混合物造成之特殊危害有害燃烧产品一氧化碳 (CO), 二氧化碳 (CO2)5.3救火员建议若发生火灾及爆炸,避免吸入烟雾. 统筹火警周遭消防措施. 消防用水不可进入排水管或水道. 分别收集受污染消防用水. 在适当距离以一般预防措施实施灭火.第6部分 泄漏应急处理6.1人员防范、保护装备与紧急程序非急救人员将人员移至安全处.紧急状况处理人员若暴露于蒸气/尘/雾/气体时穿戴呼吸器.6.2环境防范远离排水管、地表及地下水. 保留受污染清洗用水并废弃处理.6.3围阻与清洁方法及材料抑制溢漏之建议覆盖下水管清洁溢漏之建议以吸收材料擦去(例如布、刷毛布). 收集溢漏: 锯末, 硅藻土, 沙, 万用吸附剂适当围阻技术吸收材料之使用.6.4参阅其他节危害燃烧产品:参阅第 5 节. 个人防护装备:参阅第 8 节. 不相容材料:参阅第 10 节. 废弃考虑:参阅第 13 节.液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.2022第7部分 操作处置与储存7.1安全处理防范建议- 预防火灾及产生气溶胶与粉尘之措施使用区域及总通风装置. 仅在通风良好处使用.一般工作卫生建议使用后清洗双手. 在工作区域不可饮食或抽烟. 进入用餐区之前脱下受污染衣物及保护装备. 禁止将食物或饮料放置于化学品附近.禁止将化学品放置于一般用于食物或饮料之容器内. 远离饮食及动物饲料.7.2安全储存条件,包含任何不兼容性- 储存空间或容器之特殊设计- 储存温度建议储存温度: 2 – 43 °C第8部分 接触控制/个体防护8.1控制参数注记MAC 最高容许值为不应超过之暴露限制值PC-STEL 短期暴露限制:不应超过之限制值且与 15 分钟期间相关(除非另外说明)PC-TWA时量平均(长期暴露限制):测量或计算与 8 小时参考期之时间加权平均值(除非另外说明)液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.20228.2暴露控制适当工程控制总通风装置.个体保护措施(个人防护装备)眼部/面部防护穿戴眼部/脸部护具. 使用保护眼罩防止液体喷溅. 以安全眼镜工作.皮肤防护- 手部防护使用依据 EN 374 测试通过之化学保护手套. 使用前检查泄漏紧闭/抗渗性. 若要再次使用手套,脱下前先清洁手套并晾干. 特殊用途建议与上述手套供货商一起检查防护手套之化学阻力.- 材料类型PVC :聚氯乙烯, PE :聚乙烯, NR :天然橡胶、乳胶, CR :氯丁二烯橡胶, NBR :丙烯腈-丁二烯橡胶, IIR :异丁烯-异戊二烯(丁基)橡胶, FKM :氟-弹性体, PVA :聚乙烯醇, 腈- 材料厚度At least 4 mil.- 手套材质失效时间>240 分钟(渗透:5 级)- 其他保护措施给予皮肤再生复原期. 建议采取预防性皮肤保护措施(隔离乳霜/软膏). 处置后彻底清洗双手.呼吸防护穿戴呼吸护具. 半罩式面具 (EN 140). 类型:A (防护沸点 > 65 °C 之有机气体与蒸气,颜色代码:棕色).环境暴露控制使用适当容器避免环境污染. 远离排水管、地表及地下水.液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.2022第9部分 理化特性9.1基本物理与化学性质信息外观物理状态液体颜色澄清-黄色粒子不相关 (液体)气味特征性其他安全参数pH (值)9 – 9,9 (25 °C)熔点/凝固点-8 °C 初沸点与沸腾范围100 °C 闪点未定蒸发率未定可燃性(固态、气态)不相关, (流体)蒸气压0 hPa 于 25 °C密度1,16 – 1,18 g /ml 于 25 °C 蒸气密度此信息无法取得溶解度未定分配系数- 正辛醇/水 (log KOW)此信息无法取得自燃温度未定爆炸性质无氧化性质无液体低泡沫清洁剂发行日期: 18.11.2022取代版本 14.10.2022第10部分 稳定性和反应性10.1反应性考虑不相容性:参阅下列“避免情况”与“不相容材料”.10.2化学稳定性货架期限.10.3危害反应之可能性无已知危害反应.10.4避免情况不可混合其他化学品.10.5不相容材料避免长时间接触未固化的油漆、锌、铝、冷轧钢或铜及其合金。
Merck Millipore MAS-100 微生物空气监测系统说明书
![Merck Millipore MAS-100 微生物空气监测系统说明书](https://img.taocdn.com/s3/m/7013c19a8ad63186bceb19e8b8f67c1cfbd6ee67.png)
Improve your viable air sampling with the MAS-100®The most complete and accurateline of microbial air monitoring systems available!How the MAS-100® worksAll MAS-100 ® Microbial Air Monitor- ing Systems are sieve impaction sys- tems based on the Anderson impac- tion principle, accepted and proven worldwide. Air is aspirated through a perforated lid. A radial fan, controlled by a flow sensor, accurately regulates air flow real time at 100 litres/min. The air is impacted onto the surface of growth media in a 90 – 100 mm Petri dish or 55 – 60 mm Contact Plate. MAS-100 ® Microbial Air Samplers comply with the guidelines as specified in new ISO 14698 part1 and part 2.Sample collectionaccuracyThe MAS-100 ® Microbial AirMonitoring Systems provide the mostaccurate sample collection available.The MAS-100 ® systems (except theMAS-100 Eco®) utilize a state-of-the-art mass flow sensor to ensure aconstant air flow rate of 100 litres/min.The MAS-100 VF® uses a state-of-the-art electronic flow control to ensurethe same constant flow rate. The massflow sensor continuously regulatesthe air flow rate during samplecollection. This allows the MAS-100 ®to automatically adjust for differencesin fill volume of Petri dishes, changesin air density and differencesbetween individual perforated lids.ICR* andICRplus Settle PlatesThe ICR Settle Plates areproduced under aseptic conditions,gamma-irradiated and triple-bagged,making them optimal for passive airsampling in isolators and cleanrooms.Furthermore, they are also suitablefor personnel monitoring, as wellas active air monitoring withMAS-100® microbial Air Samplers.* Isolators and Clean Rooms2Table of Contents04The MAS-100 Iso NT®06The MAS-100 Iso MH®08The MAS-100 VF®10The MAS-100 NT®11The MAS-100 NT® Ex 12The MAS-100 Eco®13The MAS-100 CG Ex®14The DA-100 NT®15Services & Support16ICR & ICRplus Settle Plates 18Ordering Information34100 The MAS-100 Iso NT ®For IsolatorsThe MAS-100 Iso NT® is specifically designed for use in aseptic production and sterility testing isolators. It is available in an IP54 version for increased flexibility. The MAS-100 Iso NT® is produced by GAMP 4 specifications and is compliant with guidelines as specified in ISO 14698 part1 and part 2. The MAS-100 Iso NT® uses an innovativedouble valve system which enables the sampling heads and unit to be integrated into the decontamination process of the isolator or cleanroom. The valve system allows the vaporized hydrogen peroxide(VHP), to run through the sampling head and internal flow path without damage to the instrument.5Technical specifications for MAS-100 Iso NT®The system operates with an integrated mass flow sensor and uses 90 – 100 mm Petri dishes. The sampling head mounts inside the isolator with the instrument portion on the outside. The MAS-100 Iso NT® utilizes a flexible communications packageincluding Ethernet, Profibus and 9 digital inputs/outputs. The MAS-100 Iso NT® allows for remote activation via a computer or the PLS controlled on the isolator.The new M AS-100 Iso NT® shares the same samplingaccuracy and features as the rest of the MAS-100® Family.For further information about our workshops and onsiteservices please have a look at page 15.6100 Decontaminant exaustThe MAS-100 Iso MH ®Innovation pure by Merck MilliporeThe MAS-100 Iso MH® is used to control the microbio- logical contamination of the air in isolators. A unique security concept permits the installation of the sampling heads for standard 90 – 100 mm Petri dishes at thecritical control points. All electronic and moving parts are outside the critical zone. The MAS-100 Iso MH® has an additional internal pump with flow control for automatic disinfection of the sampling head and the aspiration tube.Air exaustup to 1 meter7An innovative double valve system enables the sampling heads to be integrated into the decontamination process of the isolator. Each unit has an air- and a sterilisation pump and works fully autonomous.The MAS-100 Iso MH® is built according to GAMP 5 and corresponds to the ISO 14698 standard. It is a completly validated system designed for the highest demands.Technical Specifications for MAS-100 Iso MH®Filter (optional use)up to 10 meters8100 The MAS-100 VF ®The next generation of Air SamplersLike all MAS-100® systems, the MAS-100 VF® samples at a flow rate of 100 litres per minute. The handle enables the sampler to be mounted onto an optional tripod, thereby allowing testing at different angles for fixed applications. The perforated lid is the same as on the standard MAS-100® sampler.The new MAS-100 VF® active Air Sampler was especially developed for controlled environments. Regulatory expectations require air monitoring in manufacturing facilities because microbial contamination mayinfluence quality and reduce shelf life. The MAS-100 VF® uses 90 – 100 mm standard Petri dishes, is easy to handle and compact, while it is ideal for monitoring the quality of your environment. Its electronic speed control maintains an accurate flow rate.Technical Specifications-100 VF®The simple user menu is easily accessed and operatedby a single touch slide control. Sampling volumesare programmable from 1 – 1,000 litres, with 5 presetvolumes to assure reproducible results.910100 The MAS-100 NT ®The industry standard for viable air samplingThe MAS-100 NT ® and MAS-100 NT® Ex portable micro-bial airsamplers are the industry standard for use in critical environments. These compact yet sophisticated devices are the preferred choice for those demanding the highest quality in microbial air monitoring. The MAS-100 NT® systems feature a new 300-hole perfo-rated lid for increased collection efficiency and i mpaction speed. Both systems utilize standard 90 – 100 mm agar plates or can be adapted to fit 55 – 60 mm contact plates allowing for a low consumable cost and greater flexibility. Sampling at 100 litres per minute, thesesystems have the highest airflow accuracy available at ± 2.5 %, compared to others that can be as high as ±10 %. The integrated flow s ensor allows the user to freely interchange the perforated lids without affecting the accuracy or the calibration of the unit. Sampling volumes are also easily configurable b etween 1 and 2,000 litres. The units have an impact v elocity of 19.6 meters per second equivalent to Anderson 6 and isokinetic flow rate that will not produce turbulence in a laminar flow environment. The new SQS function will allow for smaller sampling volumes over longer periods of time, up to 50 sequences over 24 hours.The new MAS-100 NT® systems are controlled using a new menu driven, larger illuminated display allowing for quicker navigation. A programmable start delay of up to 60 minutes allows for personnel to be out of the sampling area when the sampling starts and a newaudible alarm indicating the interruption of a sampling11The MAS-100 NT ® ExExplosion prooffor use in explosion proof areas. The MAS-100 NT® Ex has received ATEx Conformity and can be used in zone 2 and gas groups 11A,11B and 11C in temperature classes T1 to T4.cycle. The MAS-100 NT® is powered by a newLithium ion rechargeable battery with an intelligent charging program that assures long battery life without routine discharging. When fully charged, the battery pack provides 7 hours of continuous operation or about 42,000 litres of total volume. The MAS-100 NT® Microbial Air Sampler also features new USB data communication port. This allows for easy download of software upgrades and easy communication with database programs. The improved communications provides an interface to the new DA-100 NT® calibration standard for fully automated calibration. The MAS-100 NT® and MAS-100 NT® Ex are the first microbial air sampling systems with automated calibration, assuring absolute accuracy.The MAS-100 NT® Ex shares all of the same functions of the MAS-100 NT® system but is specially designedTechnical specifications for MAS-100 NT® and MAS-100 NT® ExRTC (Real Time Clock) battery; good for approx. 10 years Hot-wire anemometer, numerical control, Temperature and Pressure -100 NT® Ex12Technical specifications for MAS-100 Eco®100 The MAS-100 Eco ®The MAS-100 Eco® offers an economical alternative to our highly acclaimed MAS-100® Microbial Air Samplers. This smaller, lightweight unit is ideal for applications in or out of the cleanroom. The MAS-100® Eco offers manyof the same features found on the standard MAS-100® Air Samplers, without the mass flow sensor. Like all MAS-100® systems, the MAS-100 Eco® samples at a flow rate of 100 litres per minute and uses standard90 – 100 mm Petri dishes, providing a low operating cost. The handle doubles as a stand to allow different angles for testing and an optional tripod adapter attaches to the handle for fixed applications. The simple user menu is easily accessed and controlled using single touch “yes ” or “no ” responses. Sampling volumes are programmable from 1 – 1,000 litres with 5 preset volumes to ensure reproducible results. The unit is pre-calibrated at Merck Millipore but re-calibration on-site is easy withthe addition of our DA-100® Digital Anemometer.13The MAS -100 CG Ex®The MAS-100 CG Ex ®Compressed Gas Microbial Air SamplerThe MAS-100 CG Ex® System samples at two constant flow rates, 100 L/min and 50 L/min for low flowapplications. The system will sample gas at a pressure range between 1.5 bar to 10 bar. Compressed gas isdirected through a perforated plate onto the 90 – 100 mm Petri dish. After sampling of the required volume of gas, a gradual decompression occurs automatically, preventing any sudden pressure change, avoiding possible damage to the microorganisms and improving recovery. The MAS-100 CG Ex® system is the onlycompressed gas microbial Air Sampler approved for use in Zone 2 explosion hazard areas.The unit is pre-programmed for compressed air, nitrogen, carbon dioxide and argon gas, and a total of 10 gas protocols can be programmed and stored in the unit.The automated collection process saves time and eliminates the awkward and risky manipulations required with manual methods.Technical specifications for MAS-100 CG Ex®Coated aluminum100 litres/min. + 10 % (over the pressure range) 1.5 bar to 10 bar (absolute)50 litres/min. + 10 % over the pressure range of 1.5 bar to10 bar (absolute) 50, 100, 250, 500, 1,000 litres1 to 2,000 litres, volumes individually selectable between 0 and 2,000 litres. 0 volumes are not displayed Technical specifications for Sampling Head14T h e D A -100N T ®The DA-100 NT ®Automatic calibration featureThe flow rate accuracy is ± 1.0 %, the most accurate on the market. The display also shows temperature (°C), velocity in m/sec and barometric pressure in mbar. The DA-100 NT® may be used in manual or automatic calibration modes for calibration of the MAS-100 NT® instruments.The DA-100 NT® is calibrated at Merck Millipore laboratory using a critical venturi flow standard, SWISS traceable. Certification is provided for each instrument.The DA-100 NT® Digital Anemometer is a highly accurate transfer standard used to calibrate both MAS-100® and MAS-100 NT® instruments (cannot be used on the MAS-100 CG Ex®). This digital vane anemometer spins freely on a magnetic field bearing and the revolutions are counted by a laser diode. Technical specifications for DA-100 NT®* NIST=National Institute of Standards and Technology15Services & SupportServices plans: Preventative & Curative MaintenanceMerck Millipore has the most comprehensive preventative and curative maintenance program available for microbial air sampling.The services provided include:• C omplete yearly visual, functional and perfor-mance “as found” and “as left” checks including calibration for all MAS-100® systems. • C alibration certificate (traceability fromGFW Switzerland) and complete service report is provided with every services.In addition to the above services, additional verification, calibration or preventive maintenance (included verification & calibration) options are available. We offer several contract levels to give you the possibility to enhance the coverage of the equipment e.g. spare part and repair visit can be included in your contract.Our certified service engineers can service your air sampler in our closest repair depot or directly in your lab. Contact your local sales representative for more information.Validation & Training SupportMerck Millipore aims to provide complete validation documentation to help you through the validationprocess. Our validation protocols are based on our internal product qualification test methods. These extensive protocols will enable the QC/QA Lab to quickly initiate your validation master plan and perform IQ, OQ and PQ (suitability of the test methodology) with ease.They follow international guidelines such as EP/USP and GMP.To confirm the availability of validation support for your needs, please contact your local sales representative.Traceability & Calibration AccuracyThe sample collection volume for each MAS-100® system is measured and adjusted with the DA-100 NT® System (except the MAS-100 CG Ex®), which is directly traceable to standards from GFW Switzerland. Traceability is not a guaranty of measurement accuracy, it is a chain of documentation between the last measurements made, linking it to the referenced standard. The uncertainty (accuracy) of a measurement is determined by the combined uncertainties of all measurements made by devices between the referenced standard and that devise being calibrated, this is called the “chain of comparisons”. With each link in the chain, additive uncertainty occurs. To minimize uncertainty and maintain accuracy the number of links in the chain of comparison must be minimized and the uncertainty for each link must be documented.This is the highest level of flow accuracy available from any microbial air sampler manufacturer. You can have the confidence when monitoring critical environments that every sample volume collected is accurate.Merck Millipore has experienced and trained validation engineers who are skilled to assist in validation protocol implementation within the QC microbiology laboratory, so the QC/QA departments do not have to allocate resources. A complete and technical training on your Merck Millipore air sampler is also provided during the validation engineer’s visit. Having a Merck Millipore validation protocol and on-site service eliminates high costs, both apparent and hidden, and helps ensure the validation is completed quickly and economically and guarantee optimal performance over the equipment life time. Contact your local sales representative for the availability of training at your site.16ICR and ICRplus Settle PlatesThe ICR and ICRplus Settle Plates are produced under aseptic conditions, gamma-irradiated and triple-bagged, making them optimal for active air monitoring with MAS-100® Microbial Air Samplers. All of the MAS-100® Air Samplers have been validated according to ISO 14698 using ICR and ICRplus Settle Plates – they all showed the same reliable results in physical and biological efficiency testing.I C R a n d I C R p l u s S e t t l e P l a t e s17Close-up of the new two way closure systemFor use in isolators and cleanrooms • O ne product for all applications •V HP-impermeable packagingRecommended Casein Soya Bean Digest Agar (TSA) acc. to USP and FDA • F ormulations with neutralizers forthe inactivation of disinfectant • A dd-On: Chocolate Agar + LTH – ICRplusfor the detection of fastidious bacteriaRoom temperature storage• S torage at site of use • L ess cooling capacity neededICRplus Settle Plates – Secure your samples during transport with the innovative two way closure system • C LOSED-position for safe transportand aerobic incubation • V ENT-position for anaerobic/microaerophilic incubation18MAS-100 NT® Air Samplerwith hard carrying case, battery, 300-hole perforated lid, dust cover, mains charger, USB cable, 3 mm allen key, and operator’s manual on CD 1.09191.0001MAS-100 NT® Perforated Lid, Aluminum, 300-hole 1.09195.0001MAS-100 NT® Perforated Lid, Aluminum, 400-hole 1.09088.0001MAS-100 NT® Perforated Lid, Stainless Steel, 400-hole 1.09424.0001MAS-100 NT® Dust Cover, Aluminum 1.09084.0001MAS-100 NT® Li-Ion Battery 1.09208.0001MAS-100 NT® Mains Charger1.09200.0001MAS-100 NT® Ex Air Sampler, Explosion Proofwith hard carrying case, battery, 300-hole perforated lid, dust cover, mains charger, USB cable, 3 mm allen key, and operator’s manual on CD 1.09194.0001MAS-100 NT® Ex Perforated Lid, Aluminum, 300-hole 1.09195.0001MAS-100 NT® Ex Perforated Lid, Aluminum, 400-hole 1.09088.0001MAS-100 NT® Ex Dust Cover1.09084.0001MAS-100 Eco® Air Samplerwith hard carrying case, battery, 400-hole perforated lid, dust cover, mains charger, 3 mm allen key, and operator’s manual on CD 1.09227.0001MAS-100 Eco® Perforated Lid, Aluminum, 400-hole 1.09088.0001MAS-100 Eco® Dust Cover, Aluminum 1.09084.0001MAS-100 Eco® Mains Charger 1.09128.0001MAS-100 Eco® Tripod Adapter 1.09127.0001MAS-100 Eco® Dust Cover1.09084.0001MAS-100 CG Ex® Air Samplerwith sampling head (50 L/min), hose, mains charger, operator’s manual on CD 1.09327.0001MAS-100 CG Ex® Sampling Head1.09237.0001MAS-100 Iso NT MH® Control unit, 1 head1.17174.0001MAS-100 Iso NT MH® Control unit with Profibus, 1 head 1.17177.0001MAS-100 Iso NT MH® Control unit with Ethernet, 1 head 1.17178.0001MAS-100 Iso NT MH® Control unit, 2 heads1.17118.0001MAS-100 Iso NT MH® Control unit with Profibus, 2 heads 1.17144.0001MAS-100 Iso NT MH® Control unit with Ethernet, 2 heads 1.17145.0001MAS-100 Iso NT MH® Control unit, 3 heads1.17146.0001MAS-100 Iso NT MH® Control unit with Profibus, 3 heads 1.17147.0001MAS-100 Iso NT MH® Control unit with Ethernet, 3 heads 1.17148.0001MAS-100 Iso NT MH® Control unit, 4 heads1.17149.0001MAS-100 Iso NT MH® Control unit with Profibus, 4 heads 1.17155.0001MAS-100 Iso NT MH® Control unit with Ethernet, 4 heads 1.17157.0001MAS-100 Iso NT® Isolator System 1.09168.0001MAS-100 Iso NT® Control unit with Profilbus 1.09173.0001MAS-100 Iso NT® Control unit with Ethernet 1.09174.0001MAS-100 VF®1.17103.0001MAS-100 VF® power supply 1.17104.0001MAS-100 VF® Petri dish clamps, 3 1.17171.0001Quick Adaptor for Tripod1.09223.0001Ordering InformationAccessoriesMAS-100 Iso NT® IP54 Kit 1.17159.0001MAS-100 Iso NT® Perforated lid, stainless steel, 300-hole edge protected 1.09189.0001MAS-100 Iso NT® Perforated lid, stainless steel, 400-hole edge protected 1.09222.0001MAS-100 Iso NT® Base for sampling head, stainless with Tri-Clamp and gasket 1.09328.00011.17091.0001MAS-100 Iso NT® Easy clean base for sampling head, stainless steel,with 1 Tri-Clamp & 1 gasketMAS-100 Iso NT® Perforated lid, stainless steel, 300-hole 1.09329.0001MAS-100 Iso NT® Perforated lid, stainless steel, 400-hole 1.09424.0001MAS-100 Iso NT® Tri-Clamp, stainless steel 1.09440.0001MAS-100 Iso NT® Dust Cover, stainless steel 1.09644.0001MAS-100 Iso NT® Remote Control 1.17181.0001MAS-100 Iso NT® Elbow Joint with 2 Tri-Clamps 1.17083.0001MAS-100 Iso NT® Power Supply 1.17182.0001MAS-100 Iso MH® Power Supply 1.09784.0001MAS-100 Iso NT® Silicone Gasket 1.170.840.001MAS-100 Iso NT® Pressure Test Kit 1.170.850.001MAS-100 Iso NT® Silicone gaskets for easy clean base 1.170.990.0014" Opticap XL 4KTGRA04TT35" Opticap XL 5KTGRA05TT1M Air T® Isolator Tubing 3 m ATBTUBE01Flexable tube connector PF01501Tripod 1.09326.0001Tripod adaptor for MAS-100 Eco® 1.09127.0001MAS-100® Mains Charger 1.09085.0001MAS-100® Tube Adaptor 1.09224.0001Contact Plate Adaptor 1.09214.0001Perforated Lid for Contact Plates 1.09213.0001MAS-100® NiMH Battery Pack (for Version 2.7x or higher) 1.09229.0001MAS-100® Power supply 1.09085.0001Note: The 300-hole perforated lid is compatible with legacy systems, but a specific calibration is requiredValidation Protocols (A4)MAS-100 VF® Functional testing (A4)MAVFA4FT1MAS-100 Iso NT® Validation Protocol (A4)MAISA4VP1MAS-100 Iso MH® Validation Protocol (A4)MAMHA4VP1MAS-100 NT® Validation Protocol (A4)MANTA4VP119ReferencesAnderson, A.A. (1958)“New Sampler for the collection, sizing and enumeration of viable airborne particles.”Journal of Bacteriology, Vol 76, pp. 471-484Meier, R., Zingre, H. (2000)“Qualification of Air Sampler systems: The MAS-100®” Swiss Pharma 22, No. 1-2, pp. 15-21Feller, W.“An Introduction to Probability Theory and itsapplications”, John Wiley and Sons Inc., New York, 1950"Microbial Control and Monitoring of Aseptic Processing Environments" U.S. Pharmocopiea (USP), General Chapters <1116>, 2012 Ewald, R., and Meier, R. 2004“Detection of micro-organisms in compressed gases: Validation of MAS-100® CG using compressed gases.” Swiss Pharma, 26(10a): 16-18Merck KGaAFrankfurter Straße 25064293 Darmstadt, Germany/officesFor more information on our products:/biomonitoringFind contact information for your country at: /offices For Technical Service, please visit: /techserviceThe M logo is trademark of Merck KGaA, Darmstadt, Germany. MAS-100® is a registered trademark of MBV, Staefa, Switzerland. All other trademarks are the property of their respective owners. Lit No. PB4667EN00 08/2015© 2015 Merck KGaA, Darmstadt, Germany. All rights reserved.We provide information and advice to our customers on application technologies and regulatory matters to the best of our knowl-edge and ability, but without obligation or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties. Our information and advice do not relieve our customers of their own responsibility for checking the suitability of our products for the envisaged purpose.。
MilliporeSigma BIOshell U HPLC Columns 产品说明书
![MilliporeSigma BIOshell U HPLC Columns 产品说明书](https://img.taocdn.com/s3/m/af22cd56a22d7375a417866fb84ae45c3b35c232.png)
Faster Separation of Proteins, Peptides, and GlycansBIOshell ™U/HPLC Columnswith Fused-Core ®TechnologyThe Life Science business of Merck operates as MilliporeSigma in the U.S. and Canada.Table of ContentBIOshell TM Portfolio Overview (3)BIOshell TM IgG 1000 Å (4)BIOshell TM A400 Protein (7)BIOshell TM A160 Peptide (9)BIOshell TM Glycan (12)BIOshell TM Guard Columns (14)BIOshell TM Column Part Numbers (15)3As the pharmaceutical and biotechnology industries continuously evolve into the development of “large molecule” biotherapeutics to treat a myriad of diseases, both fast and high-resolution separations are required in order to resolve the numerous structural variants that exist in these complex samples.The BIOshell™ line of superficially porous particle (SPP) packed columns has been developed to aid research into understanding the subtleties of the molecule that is being developed. Highlighted Applications for these columns include:• Top-down analysis of intact proteins, monoclonal antibodies (mAbs), antibody-drug conjugates (ADCs), and other large biomolecules.• Bottom-up analysis (peptide mapping) of proteins for primary structure confirmation • Middle-up analysis of mAb fragments (light and heavy chains)• High resolution separation of released N- and O-linked glycans. BIOshell™ Glycan, Peptide, Protein, and IgG U/HPLC ColumnsThe BIOshell™ line of columns is comprised of the following• Largest pore diameter in the portfolio allowing for unrestricted access of proteins and other large molecules.• Compatible for UHPLC, HPLC, and mass spectrometry (MS).• C4, C18, and Diphenyl phasechemistries provide different selectivities.• Fast separations of biomolecules due to a more shallow shell.• Temperature stable up to 90 °C enabling high efficiency separations perfect for UHPLC, HPLC, and LC-MS assays.• C4 and C18 chemistries provide different selectivities for hydrophobic and hydrophilic proteins.• Wide range of particle sizes for both high efficiency separations and high throughput.• Peak capacities of columns capable of resolving complex peptide mixtures.• Extensive portfolio of column chemistries.• Improved retention of polar compounds and zwitterions as compared to bare silica.• Resolution of peaksunaffected by slight changes in buffer concentration.• Capable of resolving complex mixtures ofglycans (isobaric glycans with different linkages).Guide for Pore Size SelectionSmall (< 20 kDa*)90Glycan 2.7Medium (100 Da < MW < 15 kDa)160Peptide 2, 2.7, 5Large (2 kDa < MW < 500 kDa)400Protein 3.4Large (> 50 kDa)1000Protein2.7*for glycans, glycopeptides, and glycoproteins4• A 1000 Å pore diameter allows unrestricted access of large biomolecules into the particles.• Superficially porous particles (SPPs) provide narrower peak widths and improved resolution for characterization of biomolecules in comparison to fully porous particles (FPPs).• Post-translational modifications (PTMs) of expressed proteins can lead to subtle differences in molecular structure and function of the protein. These minor variants can be resolved with BIOshell™ IgG 1000 Å columns.BIOshell™ IgG 1000 Å U/HPLC Columns: Maximizing Pore Diameter to Minimize Size Exclusion• mAbs • ADCs • Biosimilars • H/D Exchange • mAb Fragments• Temperature stable up to 90 °C • Compatible with UHPLC, HPLC, and MS• Resolution of very large proteins with superior peak shape and efficiency as compared to separations on FPP-packed columns • Minimal to no LC-MS bleedBIOshell™ IgG 1000 Å Phase Chemistry PortfolioBIOshell™ IgG 1000 Å C4BIOshell™ IgG 1000 Å C18BIOshell™ IgG 1000 Å DiphenylLigand: Dimethylbutylsilane USP Designation: L26Available Particle Sizes: 2.7 µm Pore Size: 1000 ÅLigand: Diisobutyloctadecylsilane USP Designation: L1Available Particle Sizes: 2.7 µm Pore Size: 1000 ÅLigand: Diphenylmethylsilane USP Designation: L11Available Particle Sizes: 2.7 µm Pore Size: 1000 Å562.7 μm, 160Å0.0480.0410.0480.0480.0690.0360.0390.0350.0450.0410.1650.1223.4μm, 400Å2.7μm, 1000Å0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0Time, min77• A 0.2 µm-thick, porous shell with 400 Å pores leads to rapid and efficient separations of proteins.• Superficially porous particles (SPPs) provide narrower peak widths and improved resolution for characterization of biomolecules in comparison to fully porous particles (FPPs).• Ability to tolerate high temperature applications (up to 90 °C) in acidic mobile phases.BIOshell™ A400 Protein U/HPLC Columns: Minimizing Mass Transfer for Maximum Throughput• mAbs • ADCs • Biosimilars • Proteins • mAb Fragments• Temperature stable up to 90 °C • Compatible with UHPLC, HPLC, and MS• Resolution of large proteins with superior peakshape and efficiency as compared to separations on FPP-packed columns • Minimal to no LC-MS bleedBIOshell™ A400 Protein Phase Chemistry PortfolioBIOshell™ A400 Protein C4BIOshell™ A400 Protein C18Ligand: Dimethylbutylsilane USP Designation: L26Available Particle Sizes: 3.4 µm Pore Size: 400 ÅLigand: Diisobutyloctadecylsilane USP Designation: L1Available Particle Sizes: 3.4 µm Pore Size: 400 Å8• BIOshell™ A160 Peptide U/HPLC columns offer a broad portfolio of particlesizes and phase chemistries to create a superior solution for fast and efficientseparations of peptides up to 20 kDa.• Higher resolutions and higher peak capacities of peptides at ~ 50% backpressureof sub-2 µm fully porous particles (FPP)-packed columns.• Lower backpressure allows for columns to be used in series to maximize resolutionand peak capacity of complex proteomic samples or tryptic digests.• Compatible with all UHPLC and LC-MS instrumentation.BIOshell™ A160 Peptide U/HPLC Columns: High Resolution Peptide Separations• Tryptic Digests• Post-Translational Modifications (PTMs)• Polypeptides • Temperature stable up to 90 °C • pH stable from 1 – 8• Fast separations• Enhanced resolution• High peak capacityBIOshell™ A160 Peptide Phase Chemistry Portfolio BIOshell™ A160 Peptide Phenyl-HexylBIOshell™ A160 Peptide C18 BIOshell™ A160 Peptide Cyano Ligand: Dimethylphenyl-hexylsilaneUSP Designation: L11Available Particle Sizes: 2.7 µmPore Size: 160 ÅLigand: DiisobutyloctadecylsilaneUSP Designation: L1Available Particle Sizes: 2.0, 2.7, 5.0 µm Pore Size: 160 ÅLigand: DiisopropylcyanopropylsilaneUSP Designation: L10Available Particle Sizes: 2.7, 5.0 µmPore Size: 160 Å9Rapid Tryptic Digest Analysis UsingBIOshell™ A160 Peptide C18column:BIOshell™ A160 Peptide C18,15 cm x 4.6 mm I.D., 5.0 µmmobile phase:[A] Water (0.1% TFA); [B] Acetonitrile (0.1% TFA)gradient:As indicatedflow rate:As indicatedcolumn temp.:60 °Cdetector:UV, 215 nminjection:15 µLsample:Tryptic digest, 1 mg/mL, water (0.1% TFA)BIOshell™ A160 Peptide columns can more thandouble sample throughput by allowing the analyst to operate athigher flow rates without a concomitant drop in efficiency.024681012Different Phase Chemistries Allows for Alternative Selectivity for Peptidescolumns:As indicated, 15 cm x 4.6 mm I.D., 5.0 µmmobile phase:[A] Water (0.1% TFA); [B] Acetonitrile (0.1% TFA)gradient:5% B to 50% B in 30 minflow rate: 1.0 mL/mintemp:40°Cdetector:UV, 215 nminjection vol:10 μLsample:Proteins, 10 µg/mL, water (0.1% TFA)Using phase chemistries that interact with peptides using unique retention mechanisms can lead to different selectivity. BIOshell™ A160Peptid e CN, 5 µm123456789100510********Min12345678910BIOshell™ A160Peptid e C18, 5 µm0 2 4 6 8 10 120 5 10 15 20Min4 mL/min250 bar (3626 psi)2 mL/min126 bar (1827 psi)mAU215nmmAU215nm10104. LLIYSASFLYSGVPSRBIOshell™ A160 Peptide CNBIOshell™ A160 Peptide Phenyl-HexylBIOshell™ A160 Peptide C180 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 4412• BIOshell™ Glycan U/HPLC columns consist of a proprietary, pentahydroxy chemistry tethered to a 2.7 µm, 90 Å superficially porous particle (SPP).• Appropriate for USP L95 methods.• Main application is for the resolution of oligosaccharides (released and labeled glycans) via hydrophilic interaction liquid chromatography (HILIC).• Increased retention of acidic and zwitterionic analytes than bare silica columns.• Each lot of BIOshell™ Glycan particles is tested for quality control by separation of a series of labeled glycans having 2 – 25 glucose units (GU).BIOshell™ Glycan U/HPLC Columns: High Resolution Glycan SeparationsDid you know?®BIOshell™ Glycan SpecificationsSilicaType B (High purity silica)Particle Platform Superficially porous particles (SPP)Phase Chemistry Penta-hydroxy Particle Size 2.7 μm Pore Size 90 ÅCarbon Load 3.2%Surface Area 135 m 2/g pH Range2-9Max Temperature at Low pH 65 °C Max Temperature at High pH 40 °C EndcappedNo12HPLC Analysis of Procainamide-Labeled Human IgGGlycans on BIOshell™ Glycan using HILIC-FLRcolumn:mobile phase:14• Prevent strongly retained compounds from entering the column and leading to column fouling.• Ultra-low to no dispersion, easy to install and operate, and can tolerate backpressures up to 1000 bar.• Finger-tight, direct-connect units that auto-adjust to any column with a 10-32 inlet port.• The guard cartridge can be removed from and exchanged for a new one withoutremoving guard holder from the flow path.• Guard columns available for all BIOshell™ analytical geometries (2.1, 3.0, and 4.6 mm I.D.,) and phase chemistries.Column Selection Guide for Biomolecule Separations Guide to Selecting BIOshell™ UHPLC and HPLC Column PhasesBIOshell™ 90 ÅGlycan BIOshell™IgG 1000 Å C4BIOshell™ IgG 1000 ÅC18BIOshell™ IgG 1000 Å DiphenylBIOshell™ 400 ÅProtein C18BIOshell™ 400 ÅProtein C4BIOshell™ 160 ÅPeptide C18BIOshell™ 160 ÅPeptide Phenyl-HexylBIOshell™ 160 ÅPeptide CN153 x 2.163282-U ****5 x 2.163283-U 581362-U 577419-U 7.5 x 2.163284-U ****10 x 2.163288-U 582701-U 577420-U 15 x 2.163289-U 582703-U 577421-U 25 x 2.1**582704-U 577422-U 2 x 3.063306-U ****3 x 3.063307-U 582705-U 577423-U 5 x 3.063308-U 582706-U 577424-U 7.5 x 3.063311-U ****10 x 3.063313-U 582707-U 577425-U 15 x 3.063314-U 582708-U 577426-U 25 x 3.0******2 x 4.663322-U ****3 x 4.663324-U 582709-U 577427-U 5 x 4.663325-U 582710-U 577428-U 7.5 x 4.663327-U ****10 x 4.663328-U 582713-U 577429-U 15 x 4.663329-U 581348-U 577430-U 25 x 4.6**582715-U577434-UGuard Columns, Three Pack 0.5 x 2.163291-U 581349-U 577431-U 0.5 x 3.063315-U 581360-U 577432-U 0.5 x 4.663334-U 581361-U577433-UGuard Column Holder:66841-UDimensions Length (cm) x I.D. (mm)BIOshell™ Glycan 5 x 2.150991-U 10 x 2.150993-U 15 x 2.150994-U 5 x 4.650997-U 10 x 4.650998-U 15 x 4.650999-U Guard Columns, Three Pack 0.5 x 2.1**0.5 x 4.6**Guard Column Holder:66841-UFor geometries marked **, please contact technical service for custom quote options.10 x 1.0****15 x 1.067045-U **2 x 2.1**67457-U 3 x 2.1**67458-U 5 x 2.166824-U 67459-U 7.5 x 2.1**67462-U 10 x 2.166825-U 67463-U 15 x 2.166826-U 67469-U 25 x 2.1****2 x 3.0**67471-U 3 x 3.0**67472-U 5 x 3.0**67473-U 7.5 x 3.0**67474-U 10 x 3.0**67475-U 15 x 3.0**67477-U 25 x 3.0****2 x 4.6**67478-U 3 x 4.6**67482-U 5 x 4.666827-U 67483-U 7.5 x 4.6**67485-U 10 x 4.666828-U 67487-U 15 x 4.666829-U 67488-U 25 x 4.6****Guard Columns, Three Pack 0.5 x 2.166830-U 67505-U 0.5 x 3.0**67506-U 0.5 x 4.666831-U 67508-UGuard Column Holder:66841-UBIOshell™ A160 Peptide U/HPLC ColumnsDimensions Length (cm) x I.D. (mm)C18C18CN Phenyl-Hexyl C18CN5 x 0.075************100 x 0.075************150 x 0.075************5 x 0.1************100 x 0.1************150 x 0.1************5 x 0.2************10 x 0.2************150 x 0.2************5 x 0.3****67159-U 577546-U ****10 x 0.3************15 x 0.3**67093-U 67160-U 577545-U ****5 x 0.5****67161-U 577548-U ****10 x 0.5**67096-U ********15 x 0.5**67097-U 67163-U 577547-U ****3 x 1.0************5 x 1.0****67164-U 577550-U ****7.5 x 1.0************10 x 1.0************15 x 1.0**67099-U 67165-U 577549-U ****5 x 1.567284-U 66923-U ********15 x 1.567283-U 66922-U ********2 x 2.167234-U ****577523-U ****3 x 2.167238-U 66901-U 66965-U 577524-U 67001-U 67061-U 5 x 2.167239-U 66902-U 66966-U 577525-U 67002-U 67062-U 7.5 x 2.167241-U 66903-U 66967-U 577526-U 67003-U 67063-U 10 x 2.167242-U 66904-U 66968-U 577527-U 67004-U 67064-U 15 x 2.167243-U 66905-U 66969-U 577528-U 67006-U 67065-U 25 x 2.1************2 x 3.067257-U ****577529-U ****3 x 3.067263-U 66906-U 66970-U 577530-U 67007-U 67066-U 5 x 3.067267-U 66907-U 66971-U 577531-U 67008-U 67067-U 7.5 x 3.067274-U ****577532-U ****10 x 3.067275-U 66908-U 66972-U 577533-U 67011-U 67068-U 15 x 3.067277-U 66909-U 66973-U 577534-U 67012-U 67069-U 25 x 3.0************2 x 4.6******577535-U ****3 x 4.6******577536-U ****5 x 4.6**66913-U 66974-U 577537-U 67013-U 67071-U 7.5 x 4.6******577538-U ****10 x 4.6**66915-U 66975-U 577539-U 67014-U 67080-U 15 x 4.6****66976-U 577540-U 67015-U 67081-U 25 x 4.6******577544-U****Guard Columns, Three Pack 0.5 x 2.167281-U 66918-U 66977-U 577541-U 67016-U 67082-U 0.5 x 3.067282-U 66919-U 66978-U 577542-U 67017-U 67083-U 0.5 x 4.6**66921-U66979-U577543-U67018-U67084-UGuard Column Holder:66841-UWe have built a unique collection of life science brands withunrivalled experience in supporting your scientific advancements.To place an order or receive technical assistanceOrder/Customer Service: /order Technical Service: /techserviceSafety-related Information: /safetycenter MerckMillipore .com/bioshell© 2023 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved. Merck, the vibrant M, BioReliance, Millipore, Milli-Q, SAFC, Sigma-Aldrich, Supelco, BIOshell, SigmaMAb, and SILu are trademarks of Merck KGaA, Darmstadt, Germany or its affiliates. All other trademarks are the property of their respective owners. Detailed information on trademarks is available via publicly accessible resources.MK_BR5557EN Ver. 3.05017508/2023Merck KGaAFrankfurter Strasse 250 64293 Darmstadt, Germany。
MilliporeSigma Savor the Flavor 六十六版说明书
![MilliporeSigma Savor the Flavor 六十六版说明书](https://img.taocdn.com/s3/m/8ae80988b9f67c1cfad6195f312b3169a451ea32.png)
Application GuideSavor the Flavor Savory ingredients for your formulationSixteenth EditionThe Life Sciencebusiness of Merckoperates asMilliporeSigma inthe U.S. and Canada.2Savor the Flavor Sixteenth EditionIt has been said that “variety is a the spice of life” and whether you are a carnivore or herbivore we all crave and appreciate a hearty, savory or spicy dish from time to time. In this edition, we bring you a selection of ingredients that lend themselves to a diverse array of savory applications. Our ingredients’ high quality and consistency, along with our transparency are essential to your successful formulations.These ingredients are sure to add a hearty note to any flavor or fragrance formulation.Jamie Gleason Head of Flavors & FragrancesSavor the FlavorIngredients for the savory paletteAparna Oak has been actively contributing to the flavorindustry since 2005. Her inherent skills, aptitude for tastingand her breadth of knowledge about flavor compounds has allowed her to master the art of creating flavors.Aparna began her career as a flavor technologist at Weber Flavors in 2005where she quickly developed into a flavorist trainee. Her passion and perseverance helped her to become a creative flavorist and is now theDirector of Flavor Innovation at Imbibe. Over the years, she applied herskillset to lead the flavor innovation team at Imbibe and developed themasking portfolio. She is a Certified Flavor Chemist and an active memberof the Society of Flavor Chemists. She is a member of the monthly panel of certified flavorists that publishes the column ‘Organoleptic Characteristics ofFlavor Materials’ in the magazine Perfumer and Flavorist. More recently, she authored, “Plant to Glass, Oat Milk from a Flavorist’s Lens,” in 2019. Shehad the privilege to be a judge at the World Beverage Innovation AwardsPanel (FoodBev) in 2016, 2017, and 2019.It is this expertise that we bring to you in the following pages.We thank Ms. Oak for evaluating these products and hope herinsights are helpful and inspiring.3One common element to all involved is a devotion to supplying safe, delectable products to consumers around the world. We share that devotion with you.The Sigma-Aldrich® brand is dedicated to providing a variety of quality, certified flavorand fragrance ingredients with transparent and easily accessible documentation to customers around the globe. Our expertise in supply chain management helps ensure the products you need arrive to you when you need them.Not only do we supply safe, certified ingredients for flavor development, we also have a suiteof analytical tools to ensure your purity determination and composition verification tests are quick and accurate.To learn more, visit/flavors-fragrancesThe Flavor and Fragrance Industry Plays a Key Role in Our Daily Lives.4Savor the Flavor Sixteenth EditionSafe, certified ingredientsfor flavor & fragranceformulationsEgg2-Furanmethanethiolformate (FEMA # 3158)provides sulfurous notes.Spinach2-Propylpyrazine(FEMA # 3961) imparts amusty, green character toChickenfresh vegetables.6Savor the Flavor Sixteenth Edition7/flavors-fragrances This is an extremely potent ingredient with an intensely pungent sulphureous odor reminiscent of browned onion and garlic (like French onion soup). It’s also very diffusive. This ingredient will lend itself to perfect use for soup mixes especially French onion and where a browned onion garlic note is desirable, salad dressings, and coffee flavors where a smoky, old burnt coffee note is desired.2-Ethyl-4-methyl-1,3-dithiolane, ≥95%Kosher, HalalKey Organoleptic CharacteristicsGarlic, horseradish, onion, sulfurous Natural OccurrenceNot Found in Nature Aroma Characteristics 0.1% in Ethanol. Sulphury, pungent, savory, browned onion, burnt coffee like, savory, alliaceous.Taste Characteristics 1 ppm. Alliaceous, caramelized onion like, savory, smoked meat, old burnt coffee.Usage Level Ranging from 1 - 2 ppm depending on application.Product NumberW4870128Savor the Flavor Sixteenth EditionThis compound has an intense burnt, roasted yet green aroma. There is a fermented note throughout start to finish in this ingredient. This ingredient would be interesting to try in – green tea flavors, fermented vegetable/pickle flavors, cucumber, green melon, watermelon rind note, and in kombucha flavors – its green and fermented note will blend well with a kombucha base.2-Methoxypyridine, ≥98%Kosher, HalalKey Organoleptic CharacteristicsGreen, burnt, fatty Natural OccurrenceNot Found in Nature Aroma Characteristics 0.1% in Ethanol. Burnt, tobacco like, green, weedy with a fatty green undertone.Taste Characteristics 1 ppm. Green, burnt, herbal, weedy, fermented, fatty/leafy green undertone.Usage Level Ranging from 0.1 - 5 ppm depending on application.Product NumberW4639019/flavors-fragrances This compound has a sulphury yet green odor. It has a metallic nuance and pungency to it like but not quite as intense as wasabi. On dry out it has a distinct vegetative and earthy note. All these organoleptic characteristics lends this ingredient to use in flavors like – coffee, tropical fruits like passionfruit, tomato and vegetable flavors, and alliaceous blends like green garlic, green onion, and wasabi.3-(Methylthio)-1-hexanol, natural, ≥98%, FG Natural, Kosher, Halal, IFRAKey Organoleptic CharacteristicsGreen, pungent, earthy, vegetable, spicy, sulfurous Natural OccurrenceYellow passionfruit juice, jackfruit Aroma Characteristics0.1% in Ethanol. Green, sulphury, mild wasabi like, vegetative, earthy.Taste Characteristics2.5 ppm. Green, vegetal, canned, slight spice nuance at the back age Level3 - 6 ppm depending on application.Product NumberW34384710Savor the Flavor Sixteenth Edition This thioether of furfural is a very interesting compound with a raw, green yet sweet onion like undertone.Diisoamyl disulfide, ≥98%HalalKey Organoleptic CharacteristicsOnion, sweet Natural Occurrence‘Garlic vines’ of the genus Mansoa in the Brazilian and Argentinian rain forests Aroma Characteristics0.1% in Ethanol. Sweet, green, onion like undertone but not pungent.Taste Characteristics0.5 ppm. Sweet, green, raw onion like yet not age Level0.001 – 0.5 ppm depending on application.Product Number W457533S-Isopropyl-3-methylbut-2-enethioate, ≥95%, FG IFRA12Savor the Flavor Sixteenth EditionIt has a distinct fatty yet savory aroma that reminded me of roasted rotisserie chicken skin, potato French fries. Recommend use of this ingredient in flavors like – roasted chicken, French fries’ seasonings, roasted nut flavors, and fermented grain nuances like some of the aged hard liquors like whiskey, tequila.2-Pentylthiophene, ≥98%, FGKosher, HalalKey Organoleptic CharacteristicsFatty, meaty, chicken Natural OccurrenceRoasted beef, roasted chicken, potato fries, soybean Aroma Characteristics0.1% in Ethanol. Fatty, savory, meaty, rotisserie chicken skin, fermented.Taste Characteristics0.5 ppm. Fatty, animalic nuances, roasted undertone, slight age Level0.01 – 50 ppm depending on application.Product Number W43870013/flavors-fragrances As the name suggests, it is very much bacon like especially crisp fried bacon. Hence, I would recommend using this ingredient in flavors like bacon dripping fat, fried meaty notes to any meat flavors. It also has a smoky-ness to it which will lend itself to good use in seasonings for smoked meats.Bacon dithiazine, solution in EtOH KosherKey Organoleptic CharacteristicsBacon, meaty, smoky Natural OccurrenceNot Found in Nature Aroma Characteristics0.1% in Ethanol. Meaty, smoky, fatty, fried bacon.Taste Characteristics1 ppm. Savory, fatty, age Level0.04 – 2 ppm depending on application.Product Number W40175514Savor the Flavor Sixteenth EditionThis is an extremely potent ingredient with a little going a long way in your formulation. It is very sulfurous but also has an earthiness to it. I would recommend using this ingredient in flavors like chocolate, coffee, savory blends for meat rubs that include garlic and onion, sauteed mushroom note.Methyl furfuryl mercaptopropionate, ≥98%, FGHalalKey Organoleptic CharacteristicsEarthy, sulfurous Natural OccurrenceNot Found in Nature Aroma Characteristics0.1% in Ethanol. Savory, earthy, sulfurous.Taste Characteristics0.5 ppm. Burnt coffee, sauteed mushroom, dark soy sauce, earthy with a metallic age Level0.1 – 1 ppm depending on application.Product Number W45380115/flavors-fragrances This is another extremely potent ingredient with a little going a long way in your formulation. It is extremely sulfurous with gassy notes. I would recommend using this ingredient in flavors like savory blends for meat rubs that include garlic and onion, meaty, brothy notes, might work very well in soup bouillon flavors. At extremely low levels, under 2ppm – this ingredient might do wonders for a vanilla custard flavor where the egg yolk effect is desired.2-Propanethiol, natural (US), ≥98%, FG Natural (US), Kosher, HalalKey Organoleptic CharacteristicsSulfurous, earthy Natural OccurrenceGarlic, onion, beer Aroma Characteristics0.1% in Ethanol. Sulfurous, rotten eggs, savory, earthy.Taste Characteristics2.5 ppm. Eggy, old boiled egg yolks, strong taste almost burning with a metallic age Level0.1 – 200 ppm depending on application.Product Number W38975516Savor the Flavor Sixteenth EditionThis ingredient has an intense burnt, sweet, caramellic aroma. There is a maple and caramellic note throughout start to finish in this ingredient with a distinct fenugreek linger. This ingredient will be a staple one for all brown indulgent flavors like maple, caramel, butterscotch, toffee, chocolate and coffee4,5-Dimethyl-3-hydroxy-2,5-dihydrofuran-2-one, natural, ≥97%, FGNatural, Kosher, Halal, IFRAKey Organoleptic CharacteristicsCaramel, maple, sweet Natural OccurrenceCoffee, fenugreek, maple syrup, sake, sherry Aroma Characteristics0.1% in Ethanol. Sweet, brown, burnt sugar, maple.Taste Characteristics10 ppm. Brown, maple, burnt sugar, fenugreek age Level0.01 – 20 ppm depending on application.Product Number W36349917/flavors-fragrances Naturally occurring monoterpenes in many fruits, herbs, vegetables. It is a major component of essential oils such as hops, bay leaf, and lemongrass. It’s fresh green terpenic aroma is reminiscent of young green mangoes. Use of this ingredient will benefit flavors like – an unripe mango, green bell pepper, green tomato, citrus blends, lemongrass.Myrcene, sum of isomers, ≥90%, natural, FG Natural, Kosher, Halal, IFRAKey Organoleptic CharacteristicsWoody, herbaceous, balsamic Natural OccurrenceOccurs naturally in more than 200 plants, including verbena, lemongrass, hops, citrus peel oils and bay Aroma Characteristics1.0% in Ethanol. Fresh, green, citrusy, terpy, peppery, herbal.Taste Characteristics100 ppm. Green, vegetative, herbal, citrus nuance, green/unripe mango skin with a peppery back age Level0.5 – 13 ppm depending on application.Product Number W27621218Savor the Flavor Sixteenth EditionIt has a green, fatty, fried profile with a vegetative undertone – this ingredient will be very helpful in flavors like the skin part of cucumber, close to the rind note of honeydew melon, watermelon, cilantro herb or salsa flavors/dressings, meat rubs, and meat flavors like beef, beef buillion.3,5-Undecadien-2-one, 10% solution in EtOH, natural (US)Natural (US), KosherKey Organoleptic CharacteristicsCucumber, fatty, green Natural OccurrenceRoast beef Aroma Characteristics1% in Ethanol. Green, fatty, cucumber skin, fried.Taste Characteristics5 ppm. Green, Fatty, meaty, age Level1 – 30 ppm depending on application.Product Number W474625/flavors-fragrances19News with a Different Flavor.Subscribe to Our Flavors and Fragrances Newsletter Be sure to subscribe to our bi-monthly Flavors and Fragrances Newsletter, which keeps you up-to-date on everything from current events and useful trends within the industry, to new product and service enhancements that will help you successfully develop your next flavor creation. To subscribe, visit/ff-newsletter Merck KGaA Frankfurter Strasse 250 64293 Darmstadt, GermanyWant a Virtual or In-Person Demo of our NEW Ingredients?Our demo kits feature our newest ingredients, with some only manufactured by us. Request a demo by contacting your sales representative directly or by emailing **********************************. A local sales manager will then contact you directly to set up a time for you to experience our aromas first hand!。
化学品安全技术说明书
![化学品安全技术说明书](https://img.taocdn.com/s3/m/de89a61be418964bcf84b9d528ea81c758f52e93.png)
化学品安全技术说明书1. . 化学品及企业标识化学品及企业标识产品名FLUOROCARBON GEL 876M-MS (OBSOLETE)产品编号876M-MS (OBSOLETE)Nye Lubricants, Inc.制造商或供应商12 Howland RoadFairhaven, MA 02719地址美国无资料。
电话号码508-996-6721联系人电子邮件无资料。
紧急情况电话号码美国化学品运输紧急应变中心(CHEMTREC)1-800-424-9300建议用途及限制使用无资料。
发布日期07-14-2011填表时间02-12-2014替代日期07-14-20112. . 危险性概述危险性概述GHS GHS分类分类第3类易燃液体物理危险未被分类。
健康危险未被分类。
环境危险GHS GHS标记标记符 号警示词警告危险性说明易燃液体和蒸气。
防范说明预防措施远离热源/火花/明火/热表面。
- 禁止吸烟。
保持容器密闭。
容器和接收设备接地/等势联接。
使用防爆的电气/通风/照明设备。
只能使用不产生火花的工具。
采取防止静电放电的措施。
戴防护手套/防护眼罩/防护面具。
事故响应如皮肤(或头发)沾染:立即去除/脱掉所有沾染的衣服。
用水清洗皮肤/淋浴。
火灾时:使用适当的介质灭火。
安全储存存放在通风良好的地方。
保持低温。
废弃处置按照地方/区域/国家/国际规章处置内装物/容器。
其它危险未知。
3. . 成分成分成分//组成信息纯物质或混合物混合物浓度浓度((%)登记号登记号((CAS CAS号号)化学名称9002-84-030 - < 40聚四氟乙烯1317-33-53 - < 5二硫化钼60 - < 70低于报告水平的其它成分4. . 急救措施急救措施吸入如果症状加重, 将受害人从接触源移动到新鲜空气中。
请马上就医。
皮肤接触用肥皂和水冲洗。
立刻脱掉所有被污染的衣服。
用水清洗皮肤/淋浴。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
7601-90-3
231-512-4
-
在这部分中提及的R句子的全文请看第16部分。
O; R8 Xi; R36/38
R5 O, 氧化性; R8 C, 腐蚀性; R35
部分 四 急救措施 4.1 必要的急救措施描述 吸入之后:新鲜空气. 皮肤接触之后: 以大量清水冲洗. 立即除去受污染衣物.
接触眼睛后,以大量的水冲洗并请眼科医师诊治。
登陆来获取目录中产品的安全数据单。
页码 1 的 9
化学品安全技术说明书 根据欧盟(EC) No. 1907/2006的法or the calibration of spectrophotometers
防范说明 P302 + P352 如与皮肤接触,用大量肥皂和水冲洗受感染部位. P305 + P351 + P338 如与眼睛接触,用水缓慢温和地冲洗几分钟。如戴隐形眼镜并可方便地取出,取出隐形眼镜,然后继续 冲洗.
过氯酸 (>= 5 % - < 10 % )
7601-90-3
231-512-4 /
-
*)
氧化性液体, 类别1, H271 皮肤腐蚀, 类别1A, H314 腐蚀金属, 类别1, H290
*) 按照REACH法规(EC)2类物品第1907/2006号,本物质及其用途免于登记,因此无登记号,年度吨位无需登记,或可在较晚的最后登记期 限之前登记。
缩小标签(≤125 ml) 象形图或符号
警示词 警告
标签 (欧共体指令性条款67/548/EEC 或 欧共体指令性条款 1999/45/EC)
图形符号
Xi
有刺激性
R - 类 警示句 36/38
缩小标签(≤125 ml)
图形符号
Xi
刺激眼睛和皮肤。
有刺激性
2.3 其它危险 未见报道。
部分 三 成分/组成资料 化学性质
页码 3 的 9
化学品安全技术说明书 根据欧盟(EC) No. 1907/2006的法规
部分 六 泄漏应急处理 6.1 人员的预防,防护设备和紧急处理程序 对非应急人员的建议 切勿吸入蒸汽,气溶胶。 避免物质接触. 保证充分的通风。 疏散危险区域,遵守应急程序,征求专家意见。
对紧急情况处理人员的建议: 防护装备见第8部分。
登陆来获取目录中产品的安全数据单。
,评估,许可和限制)注册号
册号见第 3 节 安全处置与储存方法
1.2 有关的确定了的物质或混合物的用途和建议不适合的用途
鉴定了的多种用途
分析用试剂 欲了解有关用途的更多信息,请参考Merck Chemicals门户网站。
1.3 安全技术说明书提供者的详情
公司名称 责任部门
默克股份两合公司, 64271 达姆施塔特, 德国 * Phone:+49 6151 72-0 LS-QHC * e-mail: prodsafe@
物品编号 物品名称
108159 高氯酸钬标准液 for the calibration of spectrophotometers
Holmium(3+) perchlorate (>= 10 % - < 20 % )
14017-54-0 237-839-9
-
过氯酸 (>= 5 % - < 10 % )
5.2 源于此物质或混合物的特别的危害 不可燃。 周围火源可能引发释放危害性蒸气. 着火可能引起生成出: 氯化氢气体
5.3 给消防员的建议 消防人员的特殊保护装备 未着个人呼吸装置人员不可进入危险区域内. 保持安全距离并穿上适当的保护衣物, 避免接触皮肤.
进一步信息 防止消防水污染地表和地下水系统。 喷水雾压住气体/蒸汽/雾气。
分类 (欧共体指令性条款67/548/EEC 或 欧共体指令性条款 1999/45/EC)
Xi
有刺激性
R36/38
在这部分中提及的R句子的全文请看第16部分。
2.2 标记要素 标签 (第1272/2008号欧共体(EC)规章)
象形图或符号
警示词 警告
危险性说明 H290 可能腐蚀金属。 H315 造成皮肤刺激。 H319 造成严重眼刺激。
1.4 化学事故应急咨询电话
0532-83889090
部分 二 危险性概述
2.1 物质或混合物的危害性分类 分类 (第1272/2008号欧共体(EC)规章)
腐蚀金属, 类别1, H290 皮肤刺激, 类别2, H315 眼刺激, 类别2, H319
在这一部分中提及的H-部分的陈述的全文请见第16部分(section16)。
在这一部分中提及的H-部分的陈述的全文请见第16部分(section16)。
危险组分 (欧共体指令性条款 1999/45/EC)
化学品名称 (浓度或浓度范围)
CAS 号
EC-编号
索引编号
分类
登陆来获取目录中产品的安全数据单。
页码 2 的 9
化学品安全技术说明书 根据欧盟(EC) No. 1907/2006的法规
强酸水溶液.
危险组分 (第1272/2008号欧共体(EC)规章)
化学品名称 (浓度或浓度范围)
CAS 号
EC-编号 / 注册号
索引编号
分类
Holmium(3+) perchlorate (>= 10 % - < 20 % )
14017-54-0 237-839-9 /
-
*)
氧化性固体, 类别2, H272 皮肤刺激, 类别2, H315 眼刺激, 类别2, H319
吞食之后:立即让伤者饮水(最多 2 杯). 请教医生。
4.2 主要症状和影响,急性和迟发效应 刺激性
4.3 及时的医疗处理和所需的特殊处理的说明和指示 无资料。
部分 五 消防措施 5.1 灭火介质 灭火方法及灭火剂 根据当时情况和周围环境采用适合的灭火措施。
不合适的灭火剂 对于本物质/混合物,未规定对灭火剂的限制。
化学品安全技术说明书
根据欧盟(EC) No. 1907/2006的法规
填表时间 22.05.2012
版本 4.5
部分 一 化学品及企业标识 1.1 产品鉴别人
物品编号
108159
物品名称
高氯酸钬标准液 for the calibration of spectrophotometers
REACH(欧盟关于化学品注册 本品是一种混合物。REACH(欧盟关于化学品注册,评估,许可和限制)注