污水厂设计说明书
15万吨城市污水厂初步设计课程设计说明书
吉林农业大学课程设计计算书题目:15万吨城市污水厂初步设计目录摘要:................................... 错误!未定义书签。
1 总论................................... 错误!未定义书签。
设计任务及要求........................................... 错误!未定义书签。
大体资料................................................. 错误!未定义书签。
2整体设计 ............................... 错误!未定义书签。
工艺流程的确信........................................... 错误!未定义书签。
处置构筑物及设备型式选择................................. 错误!未定义书签。
格栅................................................ 错误!未定义书签。
泵房................................................ 错误!未定义书签。
沉砂池............................................... 错误!未定义书签。
沉淀池.............................................. 错误!未定义书签。
A2/O反映池.......................................... 错误!未定义书签。
接触池.............................................. 错误!未定义书签。
污泥处置构筑物设计说明.................................. 错误!未定义书签。
污水处理厂工艺设计说明书
妥善管理,避免二次污染。
选择先进、可靠、高效、运行管理方便、维修简便的排水专用设施。
污水处理厂保证一定程度的绿化、达到美化作用。
4
处理规模为15万m3/d的污水处理厂,污水厂运行上限按照20年计算
3.为确保处理效果,采用成熟可靠的工艺流程和处理构筑物;提高自动化程度,为 科学管理创造条件;
4.污水处理采用生物处理,污泥脱水采用机械脱水并设事故干化厂;污水采用季节 性消毒;
5.提高管理水平,保证运转中最佳经济效果;充分利用沼气资源,把沼气作为燃料;
6.查阅相关的资料确定其方案。
处理方案要体现以下优点:
15万m3/d污水处理厂设计说明书
一.
1
某城市位于我国南方,是一发展中的城市,人口增长率为每年
1.
(1)厂区附近地下水位标高561.00米(地表下);
(2)厂区附近土质构造为亚粘土;
(3)城区排水干管进厂处A管底设计标高为581.00米;
(4)受纳水体底部设计标高为571.00米;
(5)厂区内地势为西北高,东南低
0.0
月平均最高气温(℃)
32.6
年最高气温(℃)
38.7
月平均最低气温(℃)
9.7
温度在-10℃以下的天数
0Байду номын сангаас
温度在0℃以下的天数
0
年降雨量(mm/年)
1094.1
年蒸发量(mm/年)
常年主导方向
SE
最大风速(m/s)
2.
污水处理工艺设计(水质、水量统计计算、污水处理方案及处理程度、各建筑物的尺寸计算、污水处理流程、处理厂区平面布置图等);
污水厂设计说明书
污水厂设计说明书一、污水厂的设计规模设计规模:污水厂的处理水量按最高日最高时流量,污水厂的日处理量为:该厂按远期2010年一期2.6万吨/天建设完成,污水厂主要处理构筑物拟分为二组,每组处理规模为1.3万吨/天。
这样既可满足近期处理水量要求,有留有空地以三期扩建之用。
远期2.6万吨,一期建设,计算主要按远期计算,由于没有工业废水的变化系数,所以按生活污水量来取其时变化系数。
二、进出水水质该水经处理以后,水质应符合国家《污水综合排放标准》(GB8978-1996) 中的一级标准,由于进水不但含有BOD 5,还含有大量的N ,P 所以不仅要求去BOD 5 除还应去除不中的N ,P 达到排放标准。
单位:mg/L CODcr BOD 5 SS NH 3-N TP 进 水 380 190 238 49 4.9 出 水602020150.5三、处理程度的计算1.溶解性BOD 5的去除率活泩污泥处理系统处理水中的BOD 5值是由残存的溶解性BOD 5和非溶解性BOD 5二者组成,而后者主要是以生物污泥的残屑为主体。
活性污泥的净化功能,是去除溶解性BOD 5。
因此从活性污泥的净化功能来考虑,应将非溶解性的BOD 5从处理水的总BOD 5值中减去。
处理水中非溶解性BOD5值可用下列公式求得:(此公式仅适用于氧化沟) L mg e e C BOD e f /6.13)1(42.1207.0)1(42.17.0523.0523.05=-⨯⨯⨯=-⨯=⨯-⨯-∴ 处理水中溶解性BOD 5为20-13.6=6.4mg/L ∴ 溶解性BOD 5的去除率为:%63.96%1001904.6190=⨯-=η 2 .COD cr 的去除率%21.84%10038060380=⨯-=η 3.SS 的去除率%60.91%10023820238=⨯-=η 4.总氮的去除率出水标准中的总氮为15mg/L ,处理水中的总氮设计值取15mg/L ,总氮的去除率为:%39.69%100491549=⨯-=η 5.磷酸盐的去除率进水中磷酸盐的浓度为4.9mg/L 计。
污水处理厂设计说明书
贵州大学课程设计任务书课题名称污水处理工程学院土木工程学院专业给水排水工程班级 101学号 1008070030姓名程威污水处理工程课程设计任务书一、目的与任务1.目的本设计是污水处理工程教学中一个重要的实践环节,要求综合运用所学的有关知识,在设计中掌握解决实际工程问题的能力,并进一步巩固和提高理论知识。
2.任务根据已知资料,进行城市污水处理厂的工艺设计。
要求确定污水处理流程,计算各处理构筑物的尺寸,布置污水处理厂总平面图和高程图。
二、设计内容和要求1.设计说明书说明城市概况、设计任务、工程规模、水质水量、工艺流程、设计参数、主要构筑物的尺寸和个数、主要设备的型号和数量等;有关内容可参考如下所列。
第一章总论第一节设计任务和内容第二节基本资料第二章污水处理工艺流程说明污水处理工艺流程比较、论证(提出2种以上的工艺方案进行比较),污水处理工艺流程选定。
第三章污水处理构筑物设计按照选定的工艺流程,分节设计每个污水处理单元,简要论证比较,列出各构筑物的计算过程、主要设备(如水泵、鼓风机等)的选取。
第四章污泥处理构筑物的设计。
按照选定的污泥处理工艺流程,分节设计每个污泥处理单元,说明每个处理单元内的主要设备配置情况。
第五章污水厂总体布置第一节主要构(建)筑物与附属建筑物第二节污水厂平面布置第三节污水厂高程布置污水处理厂的高程计算(各构筑物内部的水头损失查阅教材或手册,构筑物之间的水头损失按管道长度计算)2设计图纸污水处理厂总平面布置图和高程布置图各一张,均为A2图幅的CAD 制图。
污水厂总平面图应按初步设计要求去完成,图上应绘出主要处理构筑物、处理建筑物、辅助构(建)筑物、附属建筑物、道路、绿化地带及厂区界限等,并用坐标表示其外形尺寸和相互距离,应有坐标轴线或坐标网格。
总平面图上绘出各种连接管渠,管道以单线条表示,并标明管径。
图中应附构(建)筑物一览表,说明各构(建)筑物的名称、数量及主要外形尺寸。
图中应附图例及必要的文字说明。
污水处理厂设计说明书
目录第一章城市概况及设计任务 (3)第二章水厂规模的确定及水质分析 (3)第一节水厂规模的确定 (4)第二节处理水质分析 (5)第三章污水处理厂工艺流程的确定 (5)第一节污水及污泥处理工艺的选择 (5)第二节工艺流程的确定 (7)第四章污水厂处理构筑物工艺设计计算.???????? 8第一节泵前中格栅设计计算 (8)第二节污水提升泵房设计计算 (10)第三节泵后提升泵房设计计算 (12)第四节平流式沉砂池设计计算...............................................14第五节辐流式初沉池设计计算(中心进水周边出水) (17)第六节传统活性污泥鼓风曝气池设计计算 (21)第七节向心辐流式二沉池设计计算(周边进水中心出水) (26)第八节接触消毒池与加氯间设计计算 (28)第九节巴式计量槽设计计算 (30)第五章污泥处理构筑物工艺设计计算 (32)第一节污泥量计算 (32)第二节污泥泵房设计计算 (33)第三节污泥重力浓缩池设计计算 (34)第四节贮泥池设计计算 (36)第五节污泥厌氧消化池设计计算 (37)第六节机械脱水间设计计算 (40)第六章污水处理厂平面布置 (42)第七章污水处理厂高程布置 (43)第一节各污水处理构筑物及连接管渠的水头损失计算 (43)第二节污水高程系统计算 (45)第三节污泥高程系统计算 (46)参考资料 (50)附:1污水处理厂总平面布置图2 污水处理厂高程布置图第一章城市概况及设计任务第一节城市概况东营市地处中纬度,背陆面海,受亚欧大陆和西太平洋共同影响,属暖温带大陆性季风气候,气候温和,四季分明。
春季回暖快,降水少,风速大,气候干燥,有"十春九旱"的特点;夏季气温高,湿度大,降水集中,有时受受台风侵袭;秋季气温急降,雨量骤减,秋高气爽;冬季雨雪稀少,寒冷干燥。
主要气象灾害有霜冻、干热风、大风、冰雹、干旱、涝灾、风暴潮灾等。
设计说明书污水处理厂
污水处理厂设计说明书目录第一章污水处理工程设计计算说明书1.1设计任务1.2设计内容1.3基本资料1.4设计水质水量计算第二章污水的一级处理2.1格栅设计计算2.2沉砂池设计计算2.3初次沉淀池设计计算第三章AA/O生物脱氮除磷工艺计算3.1设计参数3.2平面尺寸计算3.3进出水系统3.4其他管道设计3.5剩余污泥量第四章生物处理后处理4.1二次沉淀池设计计算4.2消毒设施计算4.3计量设备设计计算第五章污泥处理构筑物计算5.1污泥量计算5.2污泥浓缩池设计计算5.3贮泥池设计计算5.4污泥消化池设计计算5.5污泥脱水第六章污水处理厂布置6.1污水处理厂平面布置6.2污水处理厂高程布置第一章设计计算说明书1.1设计任务某城镇污水处理厂1.2设计内容1 •根据给定的原始资料,确定污水厂的规模和污水设计水量。
2 .按照原始资料数据进行处理方案的确定,拟定处理工艺流程,选择污水、污泥的处理构筑物,并用方框图表示。
进行工艺流程中各处理单元的处理原理说明。
3. 进行各构筑物的尺寸计算,各构筑物的设计参数应根据同类型污水的实际运行参数或参考有关手册选用。
4. 设备选型计算。
5. 平面和高程布置。
根据构筑物的尺寸,合理进行平面布置;高程布置应在完成各构筑物计算及平面布置草图后进行。
各处理构筑物应尽力采用重力流,各处理构筑物的水头损失可直接查相关资料,但各构筑物之间的连接管的水头损失则需计算确定。
6. 编写设计说明书、计算书。
1.3基本资料1、设计流量:Q 平=30000+ 28 X1000 m 3/d (No 学号,1 〜33 号)总变化系数:K Z= 1.42、污水水质:C0D=200-300mg/LBOD5=100-150 mg/LSS=200mg/LNH3-N=35 mg/LpH=6 〜93、受纳水体:位于城市的东侧自南向北,20年一遇洪水水位标高322.5m ,常水位标高320.3m。
4、选址:根据城市总体规划,污水厂拟建于该城市下游河流岸边,地势平坦,拟建处的地面标高326.30m。
县城污水处理厂设计说明书
百度文库- 让每个人平等地提升自我***县城污水处理厂污水处理一期工程初步设计文件第一册设计说明书2011年元月设计说明书参加人员名单工程名称:***县城污水处理厂一期工程编写单位:市政规划设计院工程设计证书:参加成员:工程设计负责人:工艺专业负责人:建筑专业负责人:结构专业负责人:电气专业负责人:暖通专业负责人:技经专业负责人:目录第一章概述 (9)1.1项目概况 (9)1.2编制依据及基础资料 (9)1.2.1编制依据91.2.2基础资料101.3编制范围及编制原则 (10)1.3.1编制范围101.3.2编制原则101.4采用的主要规范和标准 (11)1.5城市概况及自然条件 (12)1.5.1城市概况121.5.2自然条件131.6城市供水排水状况 (15)1.6.1供水现状151.6.2排水现状151.6.3排水规划151.7项目建设的必要性 (15)1.7.1积极参与西部大开发的需要151.7.2改善***县城生态投资环境的需要16第二章工程总体设计 (17)2.1设计年限 (17)2.2排水系统 (17)2.3污水处理规模 (17)2.4污水处理厂厂址 (17)2.5污水处理深度 (18)2.5.1污水处理厂进水水质182.5.2污水处理厂出水水质212.5.3污水处理程度22第三章工艺方案论证 (23)3.1污水、污泥处理工艺选择 (23)3.1.1项目废水水质情况分析233.1.2污水预处理工艺方案论证273.1.3污水二级处理工艺方案论证283.1.4污水强化处理方案论证363.1.5出水消毒方案393.1.6污泥处理工艺方案论证423.2工艺方案比较 (46)3.2.1方案一(改良型A2/O工艺)463.2.2方案二(CAST工艺)613.2.3技术经济比较及结论66第四章工艺设计 (68)4.1工艺设计采用的主要标准和规范 (68)4.2工艺流程及处理效率 (68)4.3生产构筑物工艺设计 (69)4.3.1进水粗格栅、污水提升泵及细格栅间694.3.2旋流沉砂池724.3.3改良型A2/O生化池734.3.4二沉池764.3.5化学除磷池764.3.6接触消毒池774.3.7出水排放槽784.3.8污泥贮池784.3.9污泥脱水间784.3.10鼓风机房80第五章建筑设计 (82)5.1设计标准和规范 (82)5.2总平面设计 (82)5.3厂区绿化 (82)5.4广场与道路交通 (83)5.5消防与安全 (83)5.6墙体做法 (83)5.7屋面做法 (83)5.8门窗 (83)5.9外装修 (84)第六章结构设计 (85)6.1工程概况 (85)6.2设计依据及设计标准 (85)6.3主要建筑材料技术指标 (86)6.4混凝土主筋保护层 (89)6.5与其它专业以及非结构构件相关的要求 (89)第七章给水排水设计 (91)7.1厂区给水 (91)7.2厂区排水 (91)第八章供电设计 (92)8.1设计范围 (92)8.2设计依据 (92)8.3供电电源 (92)8.4负荷计算及变配电系统 (93)8.4.1保护与控制948.4.2计量方式958.4.3电缆选择及敷设958.4.4照明968.4.5防雷与接地96第九章仪表及自控设计 (97)9.1仪表设计 (97)9.2自控设计 (97)9.3通讯 (99)第十章采暖通风设计 (100)10.1设计标准与规范 (100)10.2室外气象资料 (100)10.3锅炉房 (101)10.5采暖 (102)10.6通风 (102)第十一章 ......................................................................................... 环境保护与综合利用103第十二章 ............................................................................................................ 节能与节水10512.1节能措施 (105)12.2节水措施 (106)第十三章 .......................................................................................................................... 消防10713.1设计依据及原则 (107)13.2防火及消防措施 (107)13.3总图布置 (107)13.3.1建筑10713.3.2电气10813.3.3消防给水及消防设施109第十四章 ......................................................................................... 劳动安全、工业卫生11014.1劳动安全 (110)14.2工业卫生 (111)第十五章 ........................................................ 管理机构、劳动定员及建设进度设计11215.1管理机构及劳动定员 (112)15.1.1污水厂的管理机构设置11215.1.2人员编制(附定员表)及生产班次的划分11315.2建设进度 (114)15.2.1建设进度要求和计划安排11415.2.2建设阶段的划分(附建设进度表)114第十六章 ....................................................................................................... 运行成本分析11616.1成本和费用估算说明 (116)16.2总成本费用、固定成本、可变成本和经营成本 (116)第十七章 .......................................... 污水处理厂土建构(建)筑物及设备一览表11817.1污水处理厂主要构(建)筑物一览表 (118)17.2污水处理厂主要工艺设备一览表 (119)17.3污水处理厂主要电气设备一览表 (121)17.4污水处理厂主要自控设备一览表 (122)17.5污水处理厂主要仪表设备一览表 (124)17.6污水处理厂主要化验、机修及车辆一览表 (127)第十八章 ....................................................................................................... 工程效益分析12918.1环境效益 (129)18.2经济效益 (129)18.3社会效益 (130)第一章概述1.1 项目概况项目名称:***县城污水处理厂一期工程建设单位:***县禹源排水有限责任公司建设规模:污水处理厂污水处理能力为万m3/d,分期建设。
污水处理厂设计设计说明书
目录一、设计内容 (1)二、污水厂的设计规模 (2)三、进出水水质 (2)四、处理程度的计算 (2)五、城市污水处理设计 (4)1、工艺流程的比较 (4)2、工艺流程的选择 (9)六、污水处理构筑物设计 (10)1.粗格栅和提升泵房(两者合建) (10)设计计算 (11)2、细格栅和沉砂池 (13)七、污泥处理构筑物的设计计算 (25)1、污泥泵房 (25)2、污泥浓缩池 (25)八、污水厂平面,高程布置 (29)1、平面布置 (29)2、管线布置 (29)3、高程布置 (30)一、设计内容1、城市概况该市地处东南沿海,北回归线横贯市区中部,该市在经济发展的同时,城市基础设施的建设未能与经济协同发展,城市污水处理率仅为3.4%,大量的污水未经处理直接排入河流,使该城市的生态环境受到严重的破坏。
为了把该城市建设成为经济繁荣、环境优美的现代化城市,筹建该市的污水处理厂已迫在眉睫。
2、自然条件:(1)地形、地貌:该市具有中低山、丘陵、盆地和平原等多种地貌类型,地势西北高,东南低。
(2)工程地质:该市地质岩层出露白垩系地层,市区地层覆盖层为第四纪近代冲击层,厚40~60米,上层一般为耕植土、淤土、砂质粘土、亚粘土、细中砂和残积粘土。
地基承载力为1.2~3.5kg/cm2,地震等级为6级以下,电力供应良好。
(3)气象资料:该市地处亚热带,面临东海,海洋性气候特征明显,冬季暖和有阵寒,夏季高温无酷暑,历年最高温度38℃,最低温度4℃,年平均温度24℃。
常年主导风向为南风。
(4)水文资料:该市内河流最高洪水位+2.5米,最低水位-0.5米,平均水位为+0.5米,地下水位为离地面2.0米,厂区内设计地面标高为+5.0米。
二、污水厂的设计规模设计规模:污水厂的处理水量按最高日最高时流量,污水厂的日处理量为2.5万吨/天,污水厂主要处理构筑物拟分为二组,每组处理规模为1.25万吨/天。
三、进出水水质该水经处理以后,水质应符合国家《污水综合排放标准》(GB18918-2002)中的一级B标准.四、处理程度的计算1.溶解性BOD5的去除率活泩污泥处理系统处理水中的BOD5值是由残存的溶解性BOD5和非溶解性BOD5二者组成,而后者主要是以生物污泥的残屑为主体。
某城镇污水处理厂工艺初步设计设计说明书
某城镇污水处理厂工艺初步设计设计说明书设计说明书一、项目背景城镇污水处理厂位于市区,为了解决城镇污水处理问题,提高环境质量,本项目拟建设一座污水处理厂,采用先进的工艺和设备,对城镇污水进行处理,达到国家相关排放标准。
本设计说明书旨在对污水处理厂的工艺流程进行初步设计,并附带相关计算书。
二、设计目标1.处理能力:本污水处理厂的设计处理能力为每小时处理1000m³的污水量,满足城镇的日常需求。
2.出水水质:处理后的污水经过处理达到国家相关排放标准,出水水质符合要求。
3.运行稳定可靠:通过合理的工艺选择和设备配置,确保污水处理厂的运行稳定可靠,减少故障发生率和维修成本。
4.经济、环保、节能:在满足处理需求的前提下,优化设计,提高设备利用率,降低能耗和运营成本,同样也要确保环保要求的实现。
三、工艺流程1.进水预处理:将进水进行初步处理,包括格栅、砂沉池和调节池等,去除大颗粒悬浮物和沉淀杂物。
2.活性污泥法处理:采用活性污泥法进行二级处理,包括好氧池和二沉池。
好氧池中的活性污泥与污水进行接触和氧化降解,二沉池进行污泥沉淀和污水澄清。
3.三级处理:在二沉池出水后引入生物膜反应器,通过生物膜的附着作用,进一步降解有机物和氨氮等。
4.除磷处理:在生物膜反应器之后引入除磷池,加入除磷剂,去除污水中的磷。
5.消毒处理:在除磷池之后进行消毒处理,使用适当的消毒剂对处理后的水进行消毒,确保出水水质达到国家相关排放标准。
6.深度处理:对消毒处理后的水进行深度处理,包括活性炭吸附、超滤和反渗透等,以确保水质符合进一步利用或回收的水质要求。
7.储水和供水:将深度处理后的水进行储存和供水,用于城镇的农田灌溉、景观水景等用途。
四、设计参数1.进水水质:根据城镇的污水水质情况,设计进水水质参数,包括COD、BOD、SS、氨氮等。
2.设计处理能力:设计处理能力为每小时处理1000m³的污水量。
3.设备配置:根据工艺流程,选择合适的设备进行配置,包括格栅机、砂沉池、调节池、好氧池、二沉池、生物膜反应器、除磷池、消毒设备等。
污水处理厂设计计算说明书
目录摘要 (1)Abstract (1)设计说明书1. 工程概况 (2)1.1. 自然条件 (2)1.2. 进厂污水 (3)1.3. 出水水质要求 (3)2. 主工艺比选 (3)2.1. 污水水质分析 (4)2.2. 可选工艺 (5)2.2.1. 传统A2/O工艺 (5)2.3. 主工艺确定 (5)3. 工艺流程设计说明 (6)3.1. 一级处理设计说明 (6)3.1.1. 中隔栅 (6)3.1.2. 细格栅 (6)3.1.3. 沉砂池 (7)3.1.4. 污水提升泵房 (7)3.3. 污泥处理系统设计说明 (8)3.3.1. 储泥、搅拌、提升 (8)3.3.2. 污泥浓缩脱水车间 (8)3.4. 加药系统设计说明 (9)3.4.1. 加药(碱度补充)系统 (9)4. 污水厂布置说明 (9)4.1. 整体布局 (10)4.2. 办公生活区 (10)4.3. 污水处理区、动力区 (10)4.4. 污泥区、加药区 (10)摘要本工程为城市污水处理厂工艺设计(7万m3/d),地处,日处理城市污水7万方。
进厂污水氮含量较高,磷含量正常,污水处理重在脱氮,兼顾除磷。
本工程采用不设初沉池的三沟不等体积A2O工艺,采用新型的8阶段同步脱氮除磷运行模式,较传统的6阶段模式强化了除磷功能,减小了边沟体积从而减少了厌氧释磷量,具有良好的脱氮除磷效果。
三沟交替运行,构筑物集中个数少,无需初沉池二沉池;抗冲击负荷能力强,出水水质稳定,污泥稳定无需消化。
本工程采用水下推流器和薄膜微孔曝气器组合的复合曝气模式,突破了氧化沟的深度限制,达到6m,提高了氧利用效率,节能省地。
污水经过中细格栅、沉砂池等一级处理和A2O二级处理后达到排放标准,直接排放或回用。
本工程处理效果好,能耗低,厂构筑物集约,自动化程度高,管理方便。
AbstractThis projiect is "Jinan wastewater treatment factory technological design (70000m3/d) ". This project locates at Jinan in Shanxi province . Entering factory sewage nitrogen content is higher, the phosphor content is normal, the wastewater treatment is heavy to be taking off nitrogen, gives attention to both in phosphor.This project adoption doesn't establish three ditches that the beginning sinks pond not to wait the physical volume A2O type to oxidize a ditch craft and adopt new of 8 stages synchronously take off nitrogen the phosphor circulates mode, besides which, more traditional of 6 stage modes enhanced in addition to phosphor function, let up the side ditch physical volume to reduce to be disgusted with oxygen to release amount of Lin thus, had to goodly take off nitrogen in addition to phosphor effect. the water fluid matter stabilizes, dirty mire's stabilizing don't need digest.This engineering adoption underwater pushes to flow a tiny bore Pu spirit machine of machine and thin film to combine of compound Pu spirit mode, broke the depth restriction of oxidizing the ditch, raised oxygen to make use of an efficiency, economize on energy ground in the province.Sewage through medium thin space grid, sink sand pond etc. an attain exhaustion standard after oxidizing the second class processing of ditch, directly emissions or time is used.This engineering handles effective, can consume low, construct a thing inside the factory intensive, automate degree Gao, manage convenience.设计计算说明书1.工程概况1.1.自然条件本工为“城市污水处理厂工艺设计”,工程所在地为地区,工程所在地的人口、自然、气象、地址条件如下:1、设计人口(近期)46万人。
污水处理厂设计说明书
污水处理厂设计说明书一、引言污水处理是城市发展和环境保护的重要组成部分。
随着人口的增加和工业化的发展,废水排放量也不断增加,对环境造成了严重的污染。
污水处理厂的设计和建设是解决这一问题的关键。
本文将针对污水处理厂的设计进行详细说明,包括工艺流程、设备选择、操作维护等方面。
二、污水处理厂工艺流程(一)进水处理污水处理厂的工艺流程首先是进水处理,确保污水在进入厂区前得到预处理,以去除大颗粒物质和有机负荷。
常见的进水预处理工艺包括格栅、沉砂池、调节池等。
格栅可以去除大颗粒物质,沉砂池可以去除沉积物,而调节池可以平衡进水的流量和水质。
(二)生化处理生化处理是污水处理厂的核心环节,主要通过微生物的降解作用去除有机负荷。
常见的生化处理工艺有活性污泥法、厌氧处理法、膜法等。
活性污泥法是最常用的工艺,通过投加活性污泥,利用微生物对有机物进行降解,同时产生污泥和沼气,具有较高的去除率和较低的投资成本。
(三)沉淀处理生化处理后的污水需要进行沉淀处理,以去除残余的悬浮颗粒物质和污泥。
常见的沉淀池包括一沉池、二沉池和气浮池等。
一沉池适用于较小的处理规模,可以去除大部分悬浮颗粒物质;二沉池则适用于较大的处理规模,能够进一步提高去除率;气浮池则适用于高浓度悬浮物质的去除。
(四)消毒处理为了确保出水质量达标,处理后的污水需要进行消毒处理,杀灭其中的病原微生物。
常见的消毒方法有紫外线照射、氯消毒等。
紫外线照射是一种较为常用的无化学消毒方式,通过紫外线的照射,破坏微生物的生物结构;氯消毒则是通过加入氯化物,生成有氯消毒副产物,达到杀灭微生物的目的。
三、污水处理厂设备选择(一)进水预处理设备进水预处理设备的选择应根据进水水质和处理量来确定。
常见的进水预处理设备有格栅、沉砂池、调节池等。
格栅可采用机械格栅或光栅,选择应考虑排水量和清理方便性;沉砂池可采用圆形或矩形,选择应考虑沉砂效果和占地面积;调节池可根据进水水质的变化确定尺寸和配置。
污水处理厂设计说明书
贵州大学课程设计任务书课题名称污水处理工程学院土木工程学院专业给水排水工程班级 101学号 1008070030姓名程威污水处理工程课程设计任务书一、目的与任务1.目的本设计是污水处理工程教学中一个重要的实践环节,要求综合运用所学的有关知识,在设计中掌握解决实际工程问题的能力,并进一步巩固和提高理论知识。
2.任务根据已知资料,进行城市污水处理厂的工艺设计。
要求确定污水处理流程,计算各处理构筑物的尺寸,布置污水处理厂总平面图和高程图。
二、设计内容和要求1.设计说明书说明城市概况、设计任务、工程规模、水质水量、工艺流程、设计参数、主要构筑物的尺寸和个数、主要设备的型号和数量等;有关内容可参考如下所列。
第一章总论第一节设计任务和内容第二节基本资料第二章污水处理工艺流程说明污水处理工艺流程比较、论证(提出2种以上的工艺方案进行比较),污水处理工艺流程选定。
第三章污水处理构筑物设计按照选定的工艺流程,分节设计每个污水处理单元,简要论证比较,列出各构筑物的计算过程、主要设备(如水泵、鼓风机等)的选取。
第四章污泥处理构筑物的设计。
按照选定的污泥处理工艺流程,分节设计每个污泥处理单元,说明每个处理单元内的主要设备配置情况。
第五章污水厂总体布置第一节主要构(建)筑物与附属建筑物第二节污水厂平面布置第三节污水厂高程布置污水处理厂的高程计算(各构筑物内部的水头损失查阅教材或手册,构筑物之间的水头损失按管道长度计算)2设计图纸污水处理厂总平面布置图和高程布置图各一张,均为A2图幅的CAD 制图。
污水厂总平面图应按初步设计要求去完成,图上应绘出主要处理构筑物、处理建筑物、辅助构(建)筑物、附属建筑物、道路、绿化地带及厂区界限等,并用坐标表示其外形尺寸和相互距离,应有坐标轴线或坐标网格。
总平面图上绘出各种连接管渠,管道以单线条表示,并标明管径。
图中应附构(建)筑物一览表,说明各构(建)筑物的名称、数量及主要外形尺寸。
图中应附图例及必要的文字说明。
璧山污水厂说明书
璧山县璧城生活污水治理工程观音堂污水处理厂初步设计说明书目录1 概述1.1设计原则1.2设计范围1.3自然条件1.4 地形地貌1.5不良地质现象及地震1.6 环境工程地质条件2.总体设计2.1污水处理厂流域范围2.2厂址选择及确定2.3污水收集系统2.4受纳水体2.5进水水质及处理标准2.5.1 进水水质的确定2.5.2 排水水质2.5.3处理厂进、出水水质2.6工艺方案的比较与确定2.6.1生物除磷脱氮工艺方案的比较及确定2.6.2工艺流程的确定2.7 固体废弃物处置2.8厂外工程2.8.1进厂道路2.8.2厂外给水管线2.8.3 厂外道路照明2.8.4厂外通信线路2.8.5厂外供电外线3.总图设计3.1厂区总平面布置3.2竖向设计3.3管路布置3.3.1 范围及原则3.3.2 厂区给水3.3.3 厂区污水管设计3.3.4 厂区雨水管渠设计3.3.5厂区退水及超越管道设计3.3.6污泥管线设计3.3.7其它管线3.4厂区道路3.5厂区绿化3.6厂外道路3.6.1 设计等级3.6.2 路面设计3.6.3附属工程3.6.4 存在问题4.污水处理工艺设计4.1污水处理工艺流程4.2进厂污水干线及污水分配井4.3粗格栅间、进水提升泵房4.3.1 一般描述4.3.2 技术参数4.4泵房出水井、细格栅间及旋流沉砂池4.4.1泵房出水井及细格栅4.4.2 旋流沉砂池及配水井4.5 C-TECH生物反应池4.5.1一般描述4.5.2主要技术参数4.5.3主要设备及参数4.6消毒设施4.7鼓风机房4.7.1一般描述:4.7.2技术参数4.8化学除磷加药间4.9污水的计量5.污泥处理工艺设计5.1污泥处理工艺流程5.2贮泥池5.2.1 一般描述5.2.2 技术参数5.3脱水机房5.3.1 一般描述5.3.2技术参数5.4转运间(包含在脱水机房中)5.5污泥的计量6.电气设计说明6.1设计范围6.2供电电源6.3负荷计算6.4变电所及马达控制中心的设置和设备选型6.5电能计量6.6无功补偿6.7防雷、过电压保护和接地6.8用电设备的控制方式6.9照明6.10电缆敷设7仪表与自动化通信系统设计7.1设计原则7.2设计范围7.3设计方案7.4系统组成7.5测控内容7.6设计选型7.7软件配置7.8通信8.建筑结构设计说明8.1厂平面设计8.1.1厂区的坐标系统和高程系统8.1.2平面布局8.1.3竖向设计8.1.4厂区四周高差处理的基本方式8.1.5厂区内雨水排放方式8.1.6道路设计8.1.7绿化设计8.1.8技术经济指标表8.2建筑设计8.2.1建筑设计原则及依据8.2.2设计标准8.2.3建筑设计8.2.4观音堂污水处理厂主要建筑作法8.2.5建(构)筑物一览表8.3. 观音堂污水处理厂结构设计8.3.1结构设计原则及依据8.3.2地质条件8.3.3设计标准8.3.4结构设计8.3.5地基处理8.3.6池体结构设计的构造处理8.4建筑材料8.5挡土墙设计9.机械设计9.1 拦污机械9.2潜水提升泵9.3旋流沉砂池设备9.4撇水器9.5潜水污泥泵9.6浓缩脱水机9.7鼓风机9.8 阀门10.附属设施10.1 运输工具10.2 化验室10.3 附属建筑11.环境保护12.安全生产13.卫生14.防火消防15.节能16. 组织机构和人员编制16.1组织机构16.2人员编制17.工程投资及主要经济指标17.1 建设投资17.2 污水处理成本17.3 技术经济指标18.存在问题和建议19.附件:主要设备材料清单19.1 工艺部分19.2 电气部分19.3 自控部分19.4仪表部分19.5通信设备19.6运输设备19.7化验设备璧山县璧城生活污水治理工程观音堂污水处理厂初步设计说明书1 概述1.1设计原则(1)在重庆市城市总体规划、璧山县县城总体规划等的指导下,执行国家关于环境保护的政策,符合国家的有关法规、规范及标准。
环境工程课程设计——污水处理厂设计说明书
一级标准 二级标准 A 标准 B 标准 1 3 5 1 3 5 0.5 1 2 15 20 — 5(8) 8(15) 25(30)
三级标准
1.4 设计建设原则
(1)执行国家关于环境保护的政策, 符合国家地方的有关法规、 规范和标准; (2)采用先进可靠的处理工艺,确保经过处理后的污水能达到排放标准; (3)采用成熟 、高效、优质的设备,并设计较好的自控水平,以方便运行 管理; (4)全面规划、合理布局、整体协调,使污水处理工程与周围环境协调一致; (5)妥善处理污水净化过程中产生的污泥固体物,以免造成二次污染; (6)综合考虑环境、经济和社会效益,在保证出水达标的前提下,尽量减少 工程投资和运行费用; (7)近期与远期结合考虑,做出分期建设的安排,合理确定近期规模。
2.3 污水处理构筑物的选择
2.3.1 格栅 格栅由一组或数组平行的金属栅条、塑料齿钩或金属筛网、框架及相关装 置组成,倾斜安装再污水管道、泵房、集水井的进口处或污水处理厂的前端, 用来截留污水中较粗大漂浮物和悬浮物,防止堵塞和缠绕水泵机组、曝气器、 管道阀门、处理构筑物配水设施、进出水口,减少后续处理生产的浮渣,保证 污水处理设施的正常运行。 2.3.2 污水泵房 污水泵站的特点及形式: 泵站行驶的选择取决于水里条件和工程造价,其他考虑因素还有:泵站规 模大小、泵站的性质、水文地质条件、地形地物、挖渠及施工方案、管理水平、 环境性质要求、选用水泵的形式及能否就地取材等。 污水泵站的主要形式: (1)合建式矩形泵站,装设立式泵,自灌式工作台,水泵数为4台或更多 时,采用矩形,机器间、机组管道和附属设备布置方便,启动简单,占地面积 大; (2)合建式圆形泵站,装设立式泵,自灌式工作台,水泵数不超过4台, 圆形结构水力条件好,便于沉井施工法,可降低工程造价,水泵自动方便。 (3)对于自灌式泵房,采用自灌式水泵,叶轮(泵轴)低于集水池最低水
保定 化工区 污水处理厂工艺设计 计算说明书
第一部分设计说明书第1章设计概论1.1设计任务本次毕业设计的主要任务是完成保定市某化工区污水处理厂工艺设计。
工程设计内容包括:1.进行污水处理厂方案的总体设计:通过调研收集资料,确定污水处理工艺方案;进行总体布局、竖向设计、厂区管道布置、厂区道路及绿化设计;完成污水处理厂总平面及高程设计图。
2.进行污水处理厂各构筑物工艺计算:包括初步设计和设备选型。
3.进行辅助建筑物的设计:包括尺寸、面积、层数的确定;完成设备选型。
1.2概况及自然条件概况河北保定市某化工区含有生产染料及染料中间体的专业精细化工企业数十家,日排生产、生活污水共25000m3。
根据环保部门的要求,该区生产、生活污水必须经本区污水处理厂处理达标后方可外排,向南排至防洪沟。
厂区地形:厂区地形平坦,污水厂地面标高58m。
污水厂坐标定位:西南:A=0.000m, B=0.000m,东北A=300.00m, B=200.00m2、气象资料1)气温年平均12℃,夏季平均28℃,冬季平均-18℃,历年最高37℃,历年最低-23℃2)降雨量年平均850mm,日最大280mm3)相对湿度年平均64%,历年最大72%,历年最小58%4)主导风向冬季:偏西北为主夏季:偏东南为主5)冰冻期:100日1.3设计进出水水质1、设计进水水质:1)染料中间体废液、染料工艺废水及洗涤废水等CODCr 10000mg/l色度 500倍pH 9 ~ 102)其他废水(生活污水、车间冲洗地面废水等)CODCr 1000~2000mg/l色度 200倍pH 7~ 8冬季污水平均温度:10℃夏季污水平均温度:20℃2、处理后的水质要求:COD Cr100mg/l色度50倍pH 6~ 9第2章污水处理厂设计2.1 污水处理厂设计规模生产工艺中的洗涤、压滤等废水17000m3/d,生活污水8000m3/d,共计25000m3/d。
依据该区要求,污水处理场设计处理量25000 m3/d,远期规划为 m3/d。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
污水厂设计说明书 Company number:【WTUT-WT88Y-W8BBGB-BWYTT-19998】目录第一章污水厂课程设计指导与原始资料 (3)一、设计任务 (3)二、设计原始资料 (4)第二章污水处理厂设计规模的确定 (5)一、污水水量的确定 (5)二、污水厂设计规模的确定 (6)第三章污水厂处理工艺选择 (6)一、污水处理厂工艺流程方案 (6)二、方案的技术经济比较 (8)第四章污水处理构筑物设计计算 (11)一、泵前中格栅 (11)二、污水提升泵房 (13)三、泵后细格栅 (14)四、平流沉砂池 (16)五、厌氧池 (19)六、氧化沟 (20)七、辐流式二沉池 (26)八、紫外消毒间 (28)第五章污泥处理构筑物设计计算 (30)一、污泥浓缩池 (31)二、贮泥池 (34)三、污泥脱水 (34)第六章平面布置与高程布置 (35)一、污水处理厂的平面布置 (35)二、污水处理厂的高程布置 (38)第七章污水厂工程概预算 (42)参考文献 (48)第一章污水厂课程设计指导与原始资料一、设计任务某市(区)“污水厂课程设计”。
1. 设计题目:某污水厂课程设计2. 设计地点:本院3. 时间:一周(方案选择、构筑物计算在平时完成,说明书和图纸在设计周完成)4. 完成任务:确定污水厂建设规模、位置,并进行方案论证;污水厂工艺方案确定及可行性研究(进行二种方案比较);污水厂工艺设计计算,完成水厂平面布置图、高程图,单体构筑物工艺计算;设计计算说明书1份;5. 要求:完成图纸2张以上,单体构筑物不作要求,可在平时选做;设计计算说明书30页以上,附计算图表、可行性研究之方案论证;污水厂工艺设计计算并附草图。
水厂平面图、高程图选一张手工图(白纸铅笔图);设计计算说明书采用统一封面;二、设计原始资料1. 城市污水水量(根据用水量测算)工业用水排水符合城市污水管网接纳要求,城市污水水质见下表。
2.城市污水原水水质情况出水水质要求:根据一级A 标准确定COD <50/mg L 5BOD <10/mg L SS <10/mg LTN <15/mg L TP </mg L第二章 污水处理厂设计规模的确定一、污水水量的确定在人类的生活和生产中,使用着大量的水。
水在使用的过程中受到不同程度的污染,改变了原有的化学成分和物理性质,这些水称为污水或废水。
污水也包括雨水及冰雪融化水。
污水按来源的不同,分为生活污水、工业废水和降水三类。
根据设计任务书的设计需要采用分流制,不考虑雨污合建的情况,污水厂的设计规模按污水量和工业废水量来确定。
1. 生活污水量Q 生活的确定根据设计任务书,设计地区城市人口数N = 48000人,设计人均用水量q = 220 L/cap ·d生活污水量的确定以城市人口数,污水量标准或用水标准乘系数一般取k = 左右,即生活污水量Q 生活= k ·N ·q = ×21000×200 L/d = 8448000L/d = 84483/m d2. 第三产业废水量Q 三产污水的确定Q 三产污水 = 21000×200/L d ×80% = 96093/m d3. 工业废水量Q 工业废水的确定Q 工业废水 = 21000×200/L d ×150% = 211203/m d4. 集中流量Q集中的确定根据设计任务书查得Q集中=80003/m d5. 设计最高日污水量Qd的确定+Q三产污水+Q工业废水+Q集中)污水厂规模:Qd= (Q生活=(8448+9609+21120+8000)=477173/m dm s=3/设计秒流量:maxm sQ= × = 3/Qh = 2520m3/h二、污水厂设计规模的确定应满足设计地区最高日污水量Qd和设计地区最高日最高时污水量Qh这样才能真正达到设计污水处理厂的设计处理要求,才能保证污水厂的处理负荷在设计处理负荷之内,保证污水厂的高效处理能力,保证污水厂的安全运行能力,达到污水处理厂设计要求。
所以,污水厂设计规模为Qmax = 2520m3/h = 3/m s第三章污水处理厂工艺流程方案的选择一、污水处理厂工艺流程方案选择污水处理厂的工艺流程系指保证处理水达到所要求的处理程度的前提下,采用的污水处理技术各单元的有机组合。
在选定处理工艺流程的同时,还需要考虑确定各技术单元构筑物的型式,两者互为制约,互为影响。
污水处理工艺流程选定,主要以下列各项因素作为依据。
1. 污水的处理程度根据处理水的出路和污水的水质,确定污水中各种污染物的处理程度。
污水的处理程度如下表1表3-1 污水各种污染物的处理程度2. 污水水质和水量的变化情况除水质外,原污水的水量也是选定处理工艺需要考虑的因素,水质、水量变化较大的污水,应选用承受冲击负荷能力较强的处理工艺。
3. 工程造价和运行费用在处理水应达到的水质标准的前提条件,工程造价与运行费用越低越好。
以处理系统最低的总造价和运行费用为目标函数,建立二者之间的相互关系,达到最大经济比。
4. 当地的各项条件当地的地形、气候等自然条件也对污水处理工艺流程的选定具有一定的影响。
当地的原材料与电力供应等具体问题,也是选定处理工艺应当考虑的因素。
5. 运行管理对于运行管理水平有限的小型污水处理厂,宜采用操作简单、运行可靠的处理工艺;对于运行管理水平较高的大型污水处理厂,应尽量采用处理效率高、净化效果好的新工艺。
为了达到上述处理要求,即要求处理工艺既能有效地去除BOD5、COD、SS等,又能达到脱氮除磷的效果。
现有两种可供选择的工艺流程:① A2/O法处理工艺;②厌氧池+氧化沟处理工艺。
二、方案的技术经济比较两个方案见下图。
图1和图图3-1 A2/O法处理工艺图3-2 厌氧池+氧化沟处理工艺1. 技术比较:两方案的技术比较见下表2。
总的来说,这两个方案都比较好,都能达到要求处理的效果,而且工艺简单,污泥处理的难度较小,在技术上都是可行的。
表3-2 城市污水处理厂工艺流程方案比较2. 经济比较:经比较,第二套方案费用较少。
3. 比较结果:选择方案二,即“厌氧池+氧化沟”处理工艺该流程包括完整的二级处理系统和污泥处理系统。
污水经过一级处理的隔栅、沉砂池和初沉池进入二级处理的构筑物厌氧池和氧化沟,然后在二次沉淀池中进行泥水分离,二沉池出水消毒后直接排放。
二沉池的污泥部分回流到厌氧池中,剩下的进入浓缩池进行浓缩,浓缩后进入贮泥池,最后送入到脱水机房脱水后外运泥饼。
第四章污水处理工艺构筑物的设计计算一、泵前中格栅1. 设计参数设计流量Q = s栅前流速v1 = s,过栅流速v2 = s栅条宽度s = ,格栅间隙b = 21mm(中格栅)栅前部分长度,格栅倾角α = 60° 取栅前槽宽B1 =单位栅渣量ω1 = 栅渣/103 m 3污水 2. 设计计算取用2组格栅,Q1 = Q /2 = 2 = m 3/s (1)栅前水深 h=Q1/(B1×v1)=(1×=0.5m (2)栅条间隙数5.349.05.0021.060sin 35.0sin 21=⨯⨯︒==bhv Q n α(取n = 35)(3)栅槽有效宽度B = s ×(n-1) + b ×n += ×(35-1) + ×35 + = 1.28m(4)进水渠道渐宽部分长度(其中α1为进水渠展开角)(5)栅槽与出水渠道连接处的渐窄部分长度 (6)过栅水头损失(h1)因栅条边为矩形截面,取k=3,则 取其中,ε=β(s/b)4/3ε:阻力系数,与栅条断面形状有关,当为矩形断面时β=h0:计算水头损失k :格栅受污物堵塞后,水头损失增加倍数,取k=3(7)栅后槽总高度(H)取栅前渠道超高h2 = ,则栅前槽总高度H1 = h + h2 = + = 0.7m栅后槽总高度H = h + h1 + h2 = + + = 0.797m (取0.8m)(8)格栅总长度L = L1 + L2 + + + tan α = + + + + tan60°= 2.47m(9)每日栅渣量在21mm 格栅间距的情况下,取33311007.0m m W =,每日栅渣量:KQw W ⨯⨯=100086400=××86400/1000kz=4.23m 3/d宜采用机械格栅清渣二、污水提升泵房本设计采用半地下合建式泵房,它具有布置紧凑、占地少、结构节省的特点。
泵站地下埋深为,水泵采用潜污泵。
1. 设计流量根据规定排水泵站的设计流量一般均按最高日最高时污水流量决定,Qs = s 2. 集水间计算选择下面水池和上面机器间式合建式的方形泵站 (1)集水间的容积:采用相当于1台泵5分钟的容量。
W = 504/60 ×5 = 42 m3(2)集水池面积有效水深采用H = ,则集水池面积为F = 42/3 = 14 m2泵房尺寸为5×10 m3. 水泵扬程(1)提升净扬程Z =提升后最高水位-泵站吸水池最低水位:Z = - = 7.63m(2)出水管线的水头损失约0.2m(3)泵站内的管线水头损失假设为1.5m,考虑自由水头为0.5m。
(4)水泵总扬程为:H = + + + = 9.83m 取10m。
4. 选泵由Q=700L/s,H=10m,可查手册得:选用20sh-28型潜水排污泵,其各项性能如下:表4-1 选泵各项性能参数三、泵后细格栅1. 设计参数:设计流量Q = m3/s栅前流速v1 = s,过栅流速v2 = s栅条宽度s = ,格栅间隙b = 11mm 栅前部分长度,格栅倾角α= 60° 取栅前槽宽B1 =单位栅渣量ω1 = 栅渣/103m 3污水 2. 设计计算取用2组格栅,Q1 = Q/2 = 2 = 0.35 m 3/s (1)栅前水深h = Q1/(B1×v1) = (1× = 0.5m (2)栅条间隙数8.659.05.0011.060sin 35.0sin 21=⨯⨯︒==bhv Q n α (取n=66)(3)栅槽有效宽度B = s ×(n-1) + b ×n + = ×(66-1) + ×66 + = 1.58m (4)进水渠道渐宽部分长度(其中α1为进水渠展开角)(5)栅槽与出水渠道连接处的渐窄部分长度 (6)过栅水头损失(h1)因栅条边为矩形截面,取k=3,则mg v k kh h 23.060sin 81.929.0)011.001.0(42.23sin 2234201=︒⨯⨯⨯⨯===αε其中,ε=β(s/b)4/3ε:阻力系数,与栅条断面形状有关,当为矩形断面时β=h0:计算水头损失k:格栅受污物堵塞后,水头损失增加倍数,取k=3 (7)栅后槽总高度(H)取栅前渠道超高h2 = ,则栅前槽总高度H1 = h+h2 = + =栅后槽总高度H = h+h1+h2 = ++ = 1.03m(8)格栅总长度L = L1+L2+++tanα=++++tan60°=3.18m(9)每日栅渣量W = QW1/Kz = ×86400×1000Kz=5.58m3/d所以宜采用机械格栅清渣四、平流式沉砂池沉砂池的原理是利用物理原理去除污水中密度较大的污迹颗粒污染物,如泥砂,煤渣等。