中央空调毕业设计说明
空调设计说明书 毕业设计
摘要本毕业设计是为天津市综合办公楼中央空调系统,为工作人员创造一个舒适的环境。
本设计内容包括:冷负荷的计算;设计方案的确定;制冷机组的选择;空气处理设备的选择;风管系统和水系统的设计及水力计算;风管及水管的保温等。
根据有关标准,本设计中的办公室和会议室等全部采用风机盘管加新风的空调系统形式。
室内回风经风机盘管处理后和新风单独送入各空调房间。
各层风机盘管产生的凝结水统一排放到排水沟,本设计每层均设新风机组,新风由室外新风口采集,经处理后分别供给各个房间,以满足系统对新风量的需求。
室内送风均采用上送上回式散流器送风。
机房位于地下室的独立制冷机房,机房选用了两台WLSBG-I-012-A系列半封闭螺杆式冷水机组。
机组冷冻水供水温度为7℃,回水温度为12℃。
关键词:办公楼中央空调,风机盘管,新风系统AbstractThe graduation design is to design the central air-conditioning system of one post office building in the city of Tianjin , so as to create a comfortable environment for the staffs .It contains:the calculation of cooling load and heat load ; The determination of design scheme ; the selection of refrigeration units ; the selection of air handling equipments ; the estimation of air distribution method and the selection of relative equipments ; the insulation of air duct system and the chilled water pipes ;etc.According to some correlation standard , the air conditioning system of the design is Fan Coil Units plus Fresh air system for all floors which are for business hall , office and meeting room . Indoor air return after the fan-coil and the new wind into the air-conditioned rooms are not effect each other. Fan-coil layers of the condensation of water discharged into the drain. There will be a new wind-generating units in each floor from every floor. The new wind from the new outlet outdoor collection, were treated after the supply of rooms to meet the needs of system . The new wind generating units in the corridor on the external walls of the East. The air is sent in on the use of casual converter air supply.Engine room is located in the basement . the system use Two WLSBG-I-012-A series double screw water cooled water chillers . Unit chilled water supply parameters: 7℃,backwater parameters: 12℃.Key words : a central air conditioning system of an office building , fan-coil-unit plus,fresh air system目录绪论 (1)第一章工程简介 (1)1.1 工程概况 (2)1.2 设计资料 (2)1.2.1 设计依据 (2)1.2.2 土建资料 (2)1.2.3气象资料 (3)1.2.4设计参数 (3)第二章空调负荷的计算 (3)2.1 空调冷负荷计算 (3)2.1.1围护结构舜变传热形成的冷负荷 (3)2.1.2 室内冷负荷 (4)2.2 空调湿负荷的计算 (6)2.3 空调热负荷计算 (6)第三章设计方案的确定 (9)3.1空调系统的分类和比较 (9)3.2系统选择说明 (12)第四章风量的计算及空调设备的选型 (13)4.1 风机盘管系统 (13)4.1.1风机盘管的风量计算及选型 (13)4.1.2风机盘管的布置 (14)4.2 散流器的选型及校核计算 (14)4.3 新风量的计算及新风机组的选型 (15)4.3.1新风量的确定 (15)4.3.2新风系统的确定 (15)4.3.3新风机组的选型 (15)4.3.4新风机组的布置 (16)第五章空调水系统 (17)5.1 空调冷冻水系统 (17)5.1.1空调水系统的设计原则 (17)5.1.2空调水系统的阻力 (17)5.1.3水力平衡的要求 (18)5.1.4空调水系统的水力计算 (18)5.1.5空调水系统的水力计算举例 (18)5.2 空调冷凝水系统 (19)5.3空调水系统的附件 (20)5.4空调水系统的安装要求 (21)第六章空调风系统 (22)6.1空调风系统的水力计算 (22)6.1.1管内风速要求 (22)6.1.2水力计算方法 (22)6.1.3空调风系统水力计算举例 (23)6.2风口的布置 (23)6.3风管的布置及附件 (24)第七章机房设计及设备的选择 (25)7.1冷热源方案的选择 (25)7.2 冷热源机组的选型 (26)7.3 冷热源机房的设计 (26)7.4 机房其他设备选择 (27)7.4.1 冷却水泵的选型 (27)7.4.2 冷冻水泵的选型 (27)7.4.3 膨胀水箱的选型 (28)7.4.4阀门 (29)第八章管道的保温 (30)8.1 保温材料 (30)8.1.1 保温材料的选用原则 (30)8.1.2 常用保温材料 (30)8.2 保温层厚度的确定 (30)8.2.1 临界绝热直径 (30)8.2.2 保温范围 (30)8.2.3 保温结构 (30)8.2.4 保温层厚度的计算 (31)第九章空调系统的消声减震 (32)9.1 空调系统的消声 (32)9.2 空调装置的隔振 (32)9.3 减震设计 (32)第十章空调系统的防火排烟 (34)10.1 空调系统的防火措施 (34)10.2 空调系统的排烟 (34)第十一章管道的保温、防腐措施11.1管道的保温 (44)11.2管道的防腐 (45)设计的心得体会 (35)谢辞 (36)参考文献 (37)附录表 (38)绪论随着我国经济的快速发展,我国的建筑行业也正处于飞速发展的阶段,人们对生活环境的要求也越来越高,而生活环境最主要的就是居住环境,这种需求带动了我国的空调制冷业的发展,特别是在“禽流感”连续爆发之后,人们对室内空气品质(IAQ)有了更深刻的认识,室内空气的好坏直接影响到人们的健康,原来使用的空调技术已经不能满足人们的要求,对环境的需求意识已经不是简单的冷热意识,而是趋向于健康化、卫生化的需求。
家用中央空调毕业设计
家用中央空调毕业设计家用中央空调毕业设计随着科技的不断发展,人们对于生活品质的要求也越来越高。
在现代社会中,中央空调已经成为了许多家庭不可或缺的一部分。
然而,随着能源危机的日益严重,如何设计一种高效节能的家用中央空调系统成为了一个亟待解决的问题。
本文将探讨家用中央空调的毕业设计,旨在提供一种可行的解决方案。
首先,我们需要考虑的是中央空调的制冷效率。
目前市场上的中央空调系统大多采用传统的制冷剂,如氟利昂。
然而,这种制冷剂不仅对臭氧层有害,还具有较高的温室效应。
因此,我们需要寻找一种更环保的制冷剂替代氟利昂。
近年来,氢氟酸酯制冷剂被广泛研究和应用,其环保性能优于氟利昂,对臭氧层的破坏较小。
在设计中央空调系统时,我们可以考虑使用氢氟酸酯制冷剂,以提高系统的制冷效率和环保性。
其次,我们需要考虑的是中央空调的能源消耗问题。
传统的中央空调系统通常采用全天候运行的方式,不论室内温度是否需要调节,都会耗费大量的能源。
为了解决这一问题,我们可以引入智能控制技术。
通过传感器和智能算法的结合,中央空调系统可以根据室内温度和人员活动情况自动调节运行状态,从而实现能源的节约。
另外,我们还可以考虑利用太阳能等可再生能源来为中央空调系统供电,以进一步降低能源消耗。
在设计中央空调系统时,我们还需要考虑到系统的舒适性。
传统的中央空调系统往往存在温度不均匀和噪音较大的问题。
为了解决这些问题,我们可以采用多区域控制技术和静音设计。
通过将室内空间划分为不同的区域,每个区域可以独立控制温度,以满足不同人员的需求。
另外,我们还可以采用隔音材料和减振装置来降低噪音,提供更加舒适的室内环境。
最后,我们需要考虑中央空调系统的可持续性。
在设计中央空调系统时,我们应该注重系统的可维护性和可升级性。
通过模块化设计和标准化接口的应用,中央空调系统的维护和升级将变得更加方便和快捷。
另外,我们还可以考虑采用可再生材料和可回收材料来制造中央空调系统,以减少对环境的影响。
别墅中央空调设计_毕业设计说明书1 精品
毕业设计说明书别墅中央空调设计摘要户式中央空调是由一台主机通过风道过风或冷热水管接多个末端的方式来控制不同的房间以达到室内空气调节目的的空调。
采用风管送风方式,用一台主机即可控制多个不同房间并且可引入新风,有效改善室内空气的质量,预防空调病的发生。
本设计先根据工程概况计算各个房间的冷负荷和总的冷负荷,选用制冷剂直接蒸发一拖多热泵机组。
确定系统后再根据各个房间冷负荷和总冷负荷确定室内机和室外机的型号,由于型号固定,冷媒水管道参数便已确定,只需计算冷凝水管道即可。
目前,随着我国经济的逐步增长,居住条件日益改善,人们对生活环境的舒适性的要求越来越高,对家用中央空调的需求越来越大,对中央空调节能、舒适、健康更加关注。
因此,设计一项节能、舒适、健康的中央空调工程是很实际意义的。
关键词:户式中央空调负荷计算制冷剂一拖多机组AbstractHousehold central air conditioning is by a host had cold wind or by air hose end up to several different control room in order to achieve the purpose of indoor air conditioning. By the way, with a duct host can control and introducing several different room, effectively improve the indoor air quality, the air KongDiaoBing prevention. This design according to the engineering survey first calculated that the cooling load of each room and the cooling load of the direct evaporation, refrigerant heat pump units. More than yituo After the system is determined according to the cooling load of each room and cooling load of indoor and determine the type, air-conditioners, cold media because type water pipe parameters determined by calculation, and has condensed water pipe.At present, with China's economic growth, gradually improved increasingly, people living conditions for the comfort of living environment, the demand for household central air conditioning for central air conditioning energy-saving, comfortable, healthy more attention.Therefore, an energy-saving design, comfortable and healthy central air conditioning project is very practical significance.Key words: Household central air-conditioning Load calculation Refrigerants More than one unit delay目录前言 (1)1 绪论 (2)1.1户式中央空调研究背景及意义 (2)1.2户式中央空调比传统空调更具优势 (2)1.3我国户式中央空调发展 (4)1.4户式中央空调的特征及优势 (6)1.5户式中央空调系统分类及特点 (9)1.5.1 两种常见的户式中央空调系统 (9)1.5.2中央空调系统分类 (10)2 工程概况 (12)2.1工程概况 (12)2.2设计依据 (12)2.2.1 新乡市室外空调设计参数 (12)2.2.2 室内空调主要设计参数 (13)3 负荷计算 (15)3.1冷负荷计算 (15)3.1.1 外墙和屋面瞬变传热引起的冷负荷 (15)3.1.2内围护结构冷负荷 (16)3.1.3外玻璃窗瞬变传热引起的冷负荷 (16)3.1.4透过玻璃窗的日射得热引起的冷负荷 (17)3.1.5照明散热形成的冷负荷 (17)3.1.6人体散热形成的冷负荷 (18)3.1.7设备散热形成的冷负荷 (18)3.1.8渗透空气散热形成的冷负荷 (19)3.1.9食物散热形成的冷负荷 (20)3.1.10散湿量与潜热形成的冷负荷 (20)3.3计算结果 (21)4 方案确定 (23)4.1空调系统的分类 (23)4.2几种常用户式中央空调机组的适用范围 (25)5 空调设备的选择计算 (29)5.1多联机空调系统连接方式的确定 (29)5.2室内机和室外机的选择 (29)5.3设备布置和管道设计 (31)5.4制冷剂泄露注意事项 (32)5.5主机的选择 (32)5.5.1设计参数的选择 (33)5.5.2室内机的选择 (35)5.5.3室外机的选择 (36)6 空调水管系统设计 (37)6.1管道的选择 (37)6.1.1冷媒管道和冷凝水管道 (37)6.1.2分歧管的选择 (38)6.1.3冷凝水管道的选择 (38)6.2阀门 (39)7减振、消声与保温措施 (41)7.1减振措施 (41)7.1.1 主机组的减振 (41)7.1.2 管道减振 (41)7.2消声与隔声措施 (41)7.3保温设计 (43)8 总结 (44)9 致谢 (45)10 参考文献 (46)前言随着我国国民经济的发展和人们物质文化生活水平的不断提高,空调的应用已不再局限于必要的工艺过程所需的环境控制和少数公共和居住建筑内创造舒适的空气环境,而是越来越普及到寻常百姓家,成为提高他们生活质量的一部分。
别墅中央空调设计毕业设计说明
别墅中央空调设计毕业设计说明摘要户式中央空调是由一台主机通过风道过风或冷热水管接多个末端的方式来控制不同的房间以达到室内空气调节目的的空调。
采用风管送风方式,用一台主机即可控制多个不同房间并且可引入新风,有效改善室内空气的质量,预防空调病的发生。
本设计先根据工程概况计算各个房间的冷负荷和总的冷负荷,选用制冷剂直接蒸发一拖多热泵机组。
确定系统后再根据各个房间冷负荷和总冷负荷确定室内机和室外机的型号,由于型号固定,冷媒水管道参数便已确定,只需计算冷凝水管道即可。
目前,随着我国经济的逐步增长,居住条件日益改善,人们对生活环境的舒适性的要求越来越高,对家用中央空调的需求越来越大,对中央空调节能、舒适、健康更加关注。
因此,设计一项节能、舒适、健康的中央空调工程是很实际意义的。
关键词:户式中央空调负荷计算制冷剂一拖多机组iiAbstractHousehold central air conditioning is by a host had cold wind or by air hose end up to several different control room in order to achieve the purpose of indoor air conditioning. By the way, with a duct host can control and introducing several different room, effectively improve the indoor air quality, the air KongDiaoBing prevention. This design according to the engineering survey first calculated that the cooling load of each room and the cooling load of the direct evaporation, refrigerant heat pump units. More than yituo After the system is determined according to the cooling load of each room and cooling load of indoor and determine the type, air-conditioners, cold media because type water pipe parameters determined by calculation, and has condensed water pipe.At present, with China's economic growth, gradually improved increasingly, people living conditions for the comfort of living environment, the demand for household central air conditioning for central air conditioning energy-saving, comfortable, healthy more attention.Therefore, an energy-saving design, comfortable and healthy central air conditioning project is very practical significance.Key words: Household central air-conditioning Load calculation Refrigerants More than one unit delayii目录前言 (1)1 绪论 (2)1.1户式中央空调研究背景及意义 (2)1.2户式中央空调比传统空调更具优势 (2)1.3我国户式中央空调发展 (4)1.4户式中央空调的特征及优势 (6)1.5户式中央空调系统分类及特点 (9)1.5.1 两种常见的户式中央空调系统 (9)1.5.2中央空调系统分类 (10)2 工程概况 (12)2.1工程概况 (12)2.2设计依据 (12)2.2.1 新乡市室外空调设计参数 (12)2.2.2 室内空调主要设计参数 (13)3 负荷计算 (15)3.1冷负荷计算 (15)3.1.1 外墙和屋面瞬变传热引起的冷负荷 (15)3.1.2内围护结构冷负荷 (16)3.1.3外玻璃窗瞬变传热引起的冷负荷 (16)3.1.4透过玻璃窗的日射得热引起的冷负荷 (17)3.1.5照明散热形成的冷负荷 (17)3.1.6人体散热形成的冷负荷 (18)3.1.7设备散热形成的冷负荷 (18)3.1.8渗透空气散热形成的冷负荷 (19)3.1.9食物散热形成的冷负荷 (20)3.1.10散湿量与潜热形成的冷负荷 (20)3.3计算结果 (21)4 方案确定 (23)4.1空调系统的分类 (23)4.2几种常用户式中央空调机组的适用范围 (25)5 空调设备的选择计算 (29)ii5.1多联机空调系统连接方式的确定 (29)5.2室内机和室外机的选择 (29)5.3设备布置和管道设计 (31)5.4制冷剂泄露注意事项 (32)5.5主机的选择 (32)5.5.1设计参数的选择 (33)5.5.2室内机的选择 (35)5.5.3室外机的选择 (36)6 空调水管系统设计 (37)6.1管道的选择 (37)6.1.1冷媒管道和冷凝水管道 (37)6.1.2分歧管的选择 (38)6.1.3冷凝水管道的选择 (38)6.2阀门 (39)7减振、消声与保温措施 (41)7.1减振措施 (41)7.1.1 主机组的减振 (41)7.1.2 管道减振 (41)7.2消声与隔声措施 (41)7.3保温设计 (43)8 总结 (44)9 致谢 (45)10 参考文献 (46)ii前言随着我国国民经济的发展和人们物质文化生活水平的不断提高,空调的应用已不再局限于必要的工艺过程所需的环境控制和少数公共和居住建筑内创造舒适的空气环境,而是越来越普及到寻常百姓家,成为提高他们生活质量的一部分。
综合楼中央空调系统毕业设计说明书 精品
综合楼中央空调系统毕业设计说明书一、摘要本设计为南宁市综合楼中央空调系统,拟为之设计合理的中央空调系统,为室内工作人员提供舒适的工作环境。
设计内容包括:空调冷负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;空调末端处理设备的选型;风系统的设计与计算;室内送风方式与气流组织形式的选定;水系统的设计、布置与水力计算;风管系统与水管系统保温层的设计;消声防振设计等内容。
本设计依据有关规范考虑节能和舒适性要求,设计的空调系统采用风机盘管——新风系统。
关键字:办公楼;中央空调;风机盘管——新风系统;性能比较。
绪论我国暖通空调的现状及其发展进入90年代后,我国的居住环境和工业生产环境都已广泛地应用空调,空调技术已成为衡量建筑现代化水平的重要标志之一。
90年代中期,由于大城市电力供应紧张,供电部门开始重视需求管理及削峰填谷,蓄冷空调技术提到了议事日程。
近几年来,由于能源结构的变化,促进了吸收式冷热机组的快速发展,以及热泵技术在长江中下游地区的应用。
随着生产和科技的不断发展,人类对空调技术也进行了一系列的改进,同时也在积极研究环保、节能的空调产品和技术,已经投入使用了冰蓄冷空调系统、燃气空调、VAV空调系统、地源热泵系统等。
暖同空调技术的发展,必然会受到能源、环境条件的制约,所以能源的综合利用、节能、保护环境及趋向自然舒适环境必然是后发展的主题。
舒适性空调的发展健康是空调业发展的主题之一,以前的空调采用了多种健康技术,如负离子、离子集尘、多元光触媒等,这些技术的运用使空调产品的健康性能得到了极大的提升,海尔空调把负离子、离子集尘、多元光触媒、双向换新风、健康除尘等领先技术在内的高科技手段组合起来使用,发挥了巨大的威力,而未来空调进步的一个方向也就是对各种高科技的灵活运用空调气流的舒适度是健康空调的另一个标准。
传统空调的送风方式简单直吹人体,容易引起伤风、感冒、头痛、关节通等不舒适状态,因此新近推出的风可以从周围环绕,而不是对人体直吹,通过改善空调送风气流分布,令人感觉更舒适的共条—环绕立体送风、三维立体风的健康空调成了热销产品也就不足为奇了!第1页二、工程概况本大楼为坐落于南宁市的一综合楼,共五层,大楼坐北朝南,整个建筑平面近似长方形,总建筑面积为6424.8平方米,同时广州雨量集中,夏热冬冷,历年夏季日平均温度为30度.大楼内设有地下停车场,商场,超市,娱乐城,中,西餐厅,办公室,会议室等场所,以第一层的地板为水平面不计算,第一~第三层高为4.5米,第四~第五层高为3.8米.第一层设有:商场,超市空调机房X2,卫生间,消毒间,消控中心,电梯间,杂物间第二层设有:中西餐厅,空调机房X2,楼梯间,卫生间,消毒间,电梯间.第三层设有:娱乐城,空调机房X2,休息间,大小包厢,工作间,控制间,楼梯间,卫生间,消毒间,电梯间.第四,五层设有:办公室,休息大厅,空调机房X2,接待室,卫生间,楼梯间,电梯间,大小会议室根据建筑的使用实际情况,综合考虑各种要求,依据国家管理设计规范,进行了如下环保性,舒适性,实用性空调系统设计.本设计中的建筑物相关资料如下:1) 层面保温材料为无面花岗岩贴面,厚度为125mm.2)外墙外墙厚度为240mm的砖墙,内用白石灰粉刷3)外窗单层金属窗,玻璃为6mm厚的普通玻璃,80%为玻璃,并且内有活动百叶帘作为内遮阳.4)人数一楼是商场和超市,人流量较大,并兼作主要入口,因此在室内人员设为0.8人每平方米二楼是中西餐厅,根据设计手册查得,在室内人员设为2人每平方米三楼是娱乐场所,娱乐城取1人每平方米,休息室取0.8人每平方米,包厢取0.8人每平方米四,五楼是办公室,每间按10人来计算.5)照明,设备:根据建筑电气专业提供:第2页第一层用荧光灯,镇流器设置在顶棚内,荧光灯罩无通风孔,功率为60w/m². 第二层用白炽灯,功率为40w/m²第三层用白炽灯,功率为45w/m²第四,五层用白炽灯,功率为40w/m²6)空调使用时间:一楼和二楼的空调每天使用14小时,即8点到22点三楼的娱乐城的空调每天使用10小时,既17点到2点四,五楼办公室的空调每天使用11小时,既8点到18点7)劳作方式:轻度劳动。
三层别墅中央空调系统毕业设计说明书[管理资料]
河南机电高等专科学校毕业设计说明书设计题目:三层别墅中央空调系统系部专业班级学生姓名学号指导教师摘要家用中央空调是指根据国家空调设计规范的设计参数和要求进行选型设计、安装的,用于家庭的空调系统。
家用中央空调是由室外主机、室内风机盘管及其连接的风道送出冷热风以达到室内空气调节目的的空调系统,按工作原理可分为二种:一种是由大型中央空调系统的设备演化而来的空调系统如小型风冷冷水机组,小型风管机组为主机的产品;另一种是由分体壁挂空调设备演化而来的空调系统如一拖小型风管机组属集中中央空调系统,此系统由室外机组,室内风机盘管及盘管连接的送风管道组成。
送风管道通向各个需要空气调节的房间,风道系统可安装流量调节阀、风口等配件,一台主机可控制多个不同房间并且可引入新风,有效改善室内空气品质。
步入21世纪,人们对生活品质要求不断提高,住宅面积不断地扩大,以窗机、分体挂壁机和柜机为代表的传统的家用空调已不能充分满足环境、能源的需要。
目前家用空调市场上的产品,从严格意义上讲只能称为“温调”,真正的”空调”应具备空气质量调节的功能,不仅调节空气冷暖,而且可以通风换气,调节空气湿度、有机挥发物含量、细菌含量等室内空气的综合品质。
从这个意义上,家用中央空调才把人们带入到“真正的空调时代”。
这种集大型中央空调和家用空调优点于一体的小型化独立空调系统恰到好处地适应了目前市场的需求,代表了21世纪人居空调的发展趋势,更重要的是,它跨越了我国空调产业长期以来存在的“中央空调”与“家用空调”间的界限,开辟出了一个崭新的市场空间。
关键词:工作原理系统分类中央空调的现状前景家用中央空调的发展趋势SummaryHome central air conditioning is based on the design parameters of the national air-conditioning design specification and requirements for selection and design, installation, air-conditioning system for families. From outside the host home central air conditioning, indoor fan coil duct connection sends cold and hot wind in order to achieve the purpose of air conditioning indoor air-conditioning system, according to the principle can be divided into two kinds: one is the large central air-conditioning system the air-conditioning system, such as a small air-cooled chiller, small wind pipe mill equipment evolved a host of products; another split wall air conditioning equipment air conditioning system evolved like a drag small wind pipe mill is a concentrated central air conditioning system this system consists of an outdoor unit, an indoor fan coil and the coil connected to the supply duct. Supply duct leading to various rooms need air conditioning duct system can be installed flow control valve, vents and other accessories, a host can control a number of different rooms and the introduction of new wind effectively improve indoor air quality.Into the 21st century, the quality of life requirements continue to increase residential area continues to expand, the hanging wall of the machine and a windows machine, split Guiji representative of the traditional home air conditioning has not fully meet the needs of the environment, energy. Products on the domestic air conditioner market in the strict sense can only be called "warm tone" real "air-conditioned" air quality regulation should have not only regulate air heating and cooling, but also ventilation, adjust the air humidity, indoor air quality of the content of volatile organic compounds, bacteria content. In this sense, the home central air conditioning and only then people into real air conditioning era. The miniaturization of such a large central air conditioning and home air conditioning advantages one independent air-conditioning system, the right to adapt to the current market demand, and represents the development trend of the 21st century Habitat air conditioning, more importantly, across our air-conditioning industry, long-term boundaries since the presence of central air conditioning and home air conditioning, open up a new market space.Keywords: home central air conditioning works system classified the status of the central air-conditioning prospects trends目录第1节前言家用小型中央空调的发展现状 (1)外国家用小型中央空调发展现状 (1)中国家用小型中央空调发展现状 (2) (2) (2) (3)3 (4) (4)第2节建筑信息建筑概述 (6)66 (6) (6) (7)建筑围护结构信息 (7)7第3节负荷计算负荷计算特点 (8)冷负荷系数法公式 (8)负荷计算 (9)外墙和屋面瞬变传热引起的冷负荷 (9)内墙,楼板等室内传热维护结构形成的瞬时冷负荷 (9)外玻璃窗瞬变传热引起的冷负荷 (10)透过玻璃窗的日射得热引起的冷负荷 (11)设备散热形成的冷负荷 (12)人体散热形成的冷负荷 (12)门引起的冷负荷 (13)13第4节空调系统方案的确定1616第5节空调系统的计算19风机盘管处理过程 (19) (20)222324 (24) (25)272829 (29) (29) (29)设计总结 (31)致谢 (31)参考文献 (31)第1节前言中央空调(或称户式中央空调、单无式可调中央空调)是指由一个室外机产生冷(热)源,进而向各个房间供冷(热)的空调,它是属于商用空调的一种。
建环毕设说明书 中央空调系统设计
摘要摘要本次毕业设计的主要内容是对天津市某酒店进行中央空调系统设计。
该建筑位于天津市,共5层,总制冷负荷约为900KW,室内采用风机盘管系统为主。
本次设计涉及到空调系统的划分,冷热负荷的计算,空调设备的选型,风管的水力计算和布置,管道的消声,防震,冷冻机房的设计,水系统的划分,水管的水力计算及水管布置,水泵和通风机的选择,通风系统的自动控制等。
关键词:中央空调、通风设计、设备选择、水力计算、冷冻机房Abstractthe main content of this graduation design is a four-star hotel in Tianjin for central air conditioning system design. The building is located in Tianjin, a total of 5 layers, total cooling load is 900KW, indoor fan coil system. This design involves the division of the air conditioning system, cooling and heat load calculation, the selection of air conditioning equipment, duct hydraulic calculation and arrangement of pipeline of noise elimination, shockproof, the design of the cooling room, the division of water system, the hydraulic calculation of pipe and pipe arrangement, the choice of the pump and fan, ventilation system, such as automatic control目录第1章工程概况 (1)1.1室外气象参数 (1)1.2室内设计参数 (1)第2章负荷计算 (2)2.1冷负荷理论根据 (3)2.1.1房间冷负荷的构成: (3)2.1.2.房间湿负荷的构成: (3)2.1.3主要计算公式: (3)2.2新风量的计算 (7)2.2.1新风量标准的选取 (8)2.2.2新风量的确定 (8)2.2.3新风量计算结果与分析 (8)第三章方案选择与计算 (9)3.1空调系统方案选择 (9)3.2空调冷热源选择 (10)3.2.1 空调冷热源选择原则 (10)3.2.2冷热源方案比较 (11)3.2.3本工程选择计算 (12)3.3新风系统的方案确定 (13)3.4 空调水系统论证 (13)3.4.1按调节特征分类 (13)3.4.2按管路布置方式分类 (15)第四章空调设备的选择与计算 (15)4.1 风机盘管的计算与选择 (16)4.1.1 风机盘管的选择计算 (16)4.1.2 风机盘管选型 (17)4.2 新风机组的选择 (18)4.2.1 新风方案....................................................................... 错误!未定义书签。
中央空调毕业设计说明书范本(仅供参考)
×××××××××大学毕业设计(论文)机电工程系供热通风与空调工程技术专业题目:学生:指导老师:设计单位:时间:目录引言 (3)内容提要 (4)Abstract ........................................................................................................... 错误!未定义书签。
第一章、系统设计及其参数选定. (5)第二章、空调热湿负荷计算 (6)第三章、风量、送风状态参数确定 (15)第四章、设备选型 (18)第五章、风管系统的设计及阻力 (21)第六章、水管系统的设计 (26)第七章、减振降噪和保温设计 (28)第八章、电气控制要求说明 (30)总结 (31)参考文献 (32)引言随着市场经济体制的日益完善及国民经济的迅猛发展,综合国力的显著增强,人民的生活水平得到普遍提高,对生活质量也有更高的要求。
家用电器逐渐普及,空调—以前只有一部分人用得起的家电现在己走进了千家万户;并且他们现在不仅仅考虑温度问题,卫生清洁也倍受人们的关注,显然舒适性已越来越受人们重视。
因此,现在几乎所有的大型建筑都安装了空调以适应人民日益增长的需要。
空气温度、湿度、清洁度和新鲜等对人体舒适感觉都有很大的影响,所以本设计对通风空调系统进行全面地设计。
尽量满足顾客要求的同时,兼顾在投资成本和运行费用方面达到业主要求,以期达到最佳效果。
本人这次的设计任务就是对办公大楼进行通风空调工程设计。
由于本人知识有限,经验不足,又初次进行如此复杂的系统设计,在设计过程中难免有不周全和不合理之处,敬请各位同学和老师批评指正。
时间学生签名内容提要本次的设计课题为某办公楼的通风空调工程。
本座大厦位于长沙市繁华地带,高四层(带地下室),有大小会议室、办公室及展览厅等。
中央空调系统毕业设计
中央空调系统毕业设计中央空调系统是现代建筑物中不可或缺的设备之一,它可以有效地调节室内温度、湿度和空气质量,提供舒适的室内环境。
在本次毕业设计中,我们将研究并设计一套中央空调系统。
一、设计要求本中央空调系统设计要求能够适应客户的需求,具有以下特点:1、可变制冷量。
系统需要能够根据实际需求自动调节制冷量,以便节省能源和成本。
2、高效节能。
系统需要能够高效地工作,以降低能源消耗和维护成本。
3、稳定可靠。
中央空调系统需要能够稳定可靠地运行,以确保用户能够长期享受高质量的室内空气。
4、易于维护。
系统需要能够易于维护,以帮助减少维护成本和延长设备使用寿命。
二、系统结构设计中央空调系统通常由制冷机组、管道系统、风机盘管、空气处理器、控制系统等组成。
下面我们将对各个部分的设计进行详细的介绍。
1、制冷机组制冷机组是中央空调系统的核心部分,它提供制冷能力。
在本次设计中,我们将采用螺杆式压缩机和冷却塔组成的制冷机组。
螺杆式压缩机是一种高效、节能、低噪音的压缩机,适用于中大型中央空调系统。
冷却塔是用于散热的设备,可将制冷机组排出的热气散发到空气中,确保系统运行稳定。
2、管道系统管道系统是中央空调系统的输送管道,用于将制冷剂和空气输送到各个需要的地方。
在设计中,我们将采用优质的钢管和镀锌铁管,以确保系统的耐用性和稳定性。
3、风机盘管风机盘管是一个结合了换热器和风机的设备,用于加热或制冷室内空气。
在设计中,我们将采用高效的风机及风机盘管,可自动调节风量和温度,以确保室内空气质量。
4、空气处理器空气处理器是用于处理室内空气的设备,可帮助去除空气中的灰尘、细菌等有害物质。
在设计中,我们将采用高效的过滤器和新风设备,确保清新室内空气质量。
5、控制系统控制系统是中央空调系统的管控系统,用于监测和控制整个系统的运行情况。
在设计中,我们将采用PLC控制系统,结合人机交互面板,实现系统自动化管理。
三、总结设计一套高效、稳定、易维护的中央空调系统是需要综合考虑各个方面因素的。
某综合楼中央空调毕业设计说明书_secret
Other air conditioned rooms (example office, guest room, package) because the area is smaller, Uses the air blower plate tube to add the new atmosphere system, Outside the new atmosphere will process to is lower than in the room the air enthalpy value condition, Undertakes in the room completely the wet load and the partial cold loads, The new atmosphere by establishes the suspended ceiling new atmosphere unit processes after the corridor sends in various rooms, The blast uses double-decked drifting delivers the gusty area, The air blower plate tube blast selects the side to deliver the type, installs the form for the horizontal-type dark attire.
某综合楼中央空调毕业设计说明书_secret解读
摘要本设计是成都**饭店综合楼中央空调设计,该饭店为十三层建筑,并设有地下室,总建筑面积12351m2,总层高43m。
空调设计中,一、二层的大空间(商场、大堂、大堂吧等)采用全空气一次回风的空气处理方案,从节能的角度考虑,采用露点送风。
空气处理机组设在每层的空调机房内,新回风经集中处理后送入各空调房间。
气流组织采用上送上回的气流组织形式,送风口选用方形散流器,回风口采用单层百叶回风口。
其余空调房间(办公室、客房、包间)因面积较小,采用风机盘管加新风系统,将室外新风处理到低于室内空气焓值的状态,承担室内全部湿负荷和部分冷负荷。
新风由设置在走廊内的吊顶新风机组处理后送入各房间,送风采用双层百叶送风口。
风机盘管送风选用侧送式,安装形式为卧式暗装。
空调用制冷机房设在地下室,选用两台螺杆式冷水机组。
夏天使用冷水机组提供的7/12℃的冷水,冬天由换热器将来自集中锅炉房的95/70℃的锅炉供水转换为60/50℃的热水后,送入各房间。
水管路采用两管制。
冷却塔置于屋顶,每台冷水机组各配一台。
关键字:空调设计,全空气系统,风机盘管系统,冷水机组AbstractThis design is the Chengdu **hotel synthesis building central air conditioning design, This hotel is 13 constructs, And is equipped with the basement, Total floor space 13000m2.Total building store height 43m.In air conditioning design, 1F and 2F big spaces (market, great hall, great hall and so on) use the entire air time to return to the wind the air processing plan, From energy conservation angle consideration, Uses the dew point blast. The air processing unit is located in each level in the air conditioning engine room, New、returns to the wind to send in various air conditioned room after centralism processing, The air current organization form used on delivers the other day, Delivers the gusty area to select square shape drifting. Returns to the gusty area to use the monolayer drifting to return to the gusty area,Other air conditioned rooms (example office, guest room, package) because the area is smaller, Uses the air blower plate tube to add the new atmosphere system, Outside the new atmosphere will process to is lower than in the room the air enthalpy value condition, Undertakes in the room completely the wet load and the partial cold loads, The new atmosphere by establishes the suspended ceiling new atmosphere unit processes after the corridor sends in various rooms, The blast uses double-decked drifting delivers the gusty area, The air blower plate tube blast selects the side to deliver the type, installs the form for the horizontal-type dark attire.The Air conditioning refrigeration engine room is located in the basement, Selects two screw rods types cold water unit, Summer uses 7/12 ℃ cold water which the cold water unit provides, Winter the heat interchanger future since will concentrate the boiler room 95/70 ℃water transformation is 60/50 ℃ hot water, Sends in various rooms, The water pipeline uses two. The cooling tower sets to the roof, each cold water unit respectively matches.Key word: Air conditioning design, entire air system, air blower plate tube system, cold water unit.第一章绪论第一节空气调节的含义建筑是人们生活与工作的场所。
空调设计说明书——毕业设计
空调设计说明书——毕业设计目录第一章设计概况 (6)1.1设计任务 (6)1.2设计依据 (7)1.3工程概况 (8)1.4设计参数 (9)1.4.1空调室外空气的计算参数 (9)1.4.2空调室内设计参数 (11)1.4.3维护结构参数 (12)1.4.4其他冷负荷相关参数 (13)第二章空调负荷的计算 (14)2.1负荷计算概述 (14)2.2夏季空调冷负荷的计算 (15)2.2.1维护结构冷负荷 (16)2.2.2内部冷负荷 (20)2.2.3新风冷负荷 (24)2.2.4 冷负荷计算举例 (24)第三章设计方案的对比与选择 (35)3.1空调系统的分类比较 (35)3.2空调系统的确定 (39)第四章风机盘管加新风系统选型计算 (39)4.1 新风量规定 (39)4.2 风机盘管系统风量的计算(夏季) (40)4.3 风机盘管的选型 (45)第五章气流组织 (47)5.1概述 (47)5.2 气流组织方案论证 (48)5.2.1 风口形式的确定 (48)5.2.2 气流组织形式的确定 (49)5.3 气流组织计算 (49)5.3.1 风机盘管侧送风 (49)5.3.2 散流器平送气流组织计算 (51)第六章空调风管设计计算 (53)6.1风道(或称风管)分类 (53)6.2沿程阻力与局部阻力 (53)6.2.1沿程阻力 (54)6.2.2局部阻力 (55)6.3风管的水力计算 (55)6.4风管水力计算举例 (58)6.5新风机组的选型 (59)第七章空调水管系统设计 (61)7.1空调水管系统的设计原则 (61)7.2冷冻水系统的设计 (62)7.2.1冷冻水系统形式 (62)7.2.2冷冻水量计算 (63)7.2.3冷冻水泵的选择: (64)7.2.4冷冻水系统水力计算 (65)7.3冷却水系统设计 (68)7.3.1空调冷却水系统的形式 (68)7.3.2冷却塔的选型 (69)7.3.3设计计算与选择 (72)7.4冷凝水管路设计 (73)第八章冷源的选择及设备选型 (75)8.1 冷源的比较与确定 (75)摘要本设计的内容是福州市某六层商业楼全年性中央空调工程的设计,其目的对通过对中央空调系统的设计,来了解中央空调系统的设计流程及具体方法,进而巩固所学的基础知识。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
WORD毕业设计(论文)题目名称:惠新大厦中央空调系统设计学院名称:能源与环境学院班级:建环学号:学生:指导教师:年月日论文编号:惠新大厦中央空调系统设计专业:建筑环境与设备工程:教导老师:摘要本设计为惠新大厦中央空调设计。
通过方案比较,在负荷计算的基础上,采用了风机盘管加新风和全空气两种空调系统形式。
一层除了有单独办公室,还有一个长17.8m,宽15.6的办公大厅,不适合用风机盘管加新风系统,选用全空气系统。
二层到十层楼层,大部分为单独办公室,所以全部选用风机盘管加新风系统。
风机盘管为卧式暗装,新风不承担室负荷;全空气系统为一次回风系统,室送风采用散流器下送方式。
新风从墙洞引入,再由各层的新风机组集中处理供应。
冷冻水由地下室的冷冻机房供应,采用了闭式同程两管制水系统。
水管用泡沫橡塑保温,风管采用离心玻璃棉。
设计工程中考虑了消声、减振措施。
关键词:中央空调,风机盘管加新风系统,全空气系统,大厦Central Air-conditioning Design for HuiXinBuildingAbstractThe air conditioning engineering ofHuixinBuilding was designed. On the base of cooling load, heating and moisture load calculation, primary air fan-coil system and all air system are adopted by way of technical and economic analysis. In addition to individual office level, there is a length 17.8m, width of 15.6 in the office lobby, not suitable for fan coil plus fresh air system, use an all air system. The second floor to ten floors, most asa separate office, so all the fan coil selection of a new air system.The fresh air doesn’t undertake indoor load and delivers air through double deflection grille after mixing the return air in the horizontal recessed fan coil. The return air is harnessed one time by the air handling unit in the all air system and the handled air is delivered through double deflection grille by sidewall air supply. The fresh air is supplied by hole or shaft and handled by the fresh air handling unit. The chilled water which is a closed two-pipe direct return water system is supplied by the refrigerating plant room. The thermal insulation material of water pipe and air duct are foam plastics and centrifugal glass wool respectively. Measures of noise elimination, damp, fire prevention and smoke extraction is considered during the design. KeyWords:air conditioningprimary air fan-coil systemall air system building.目录目录II1 工程概况- 1 -1.1原始资料-1-1.2计算参数-1-1.2.1基本气象参数- 1 -1.2.2室外计算参数- 1 -1.2.3室设计参数- 1 -1.3动力资料:-2-1.4土建资料-2-2 负荷计算-3 -2.1围护结构瞬变传热形成冷负荷的计算方法错误!未指定书签。
2.1.1外墙和屋面瞬变传热引起的冷负荷- 3 -2.1.2墙,楼板等室传热维护结构形成的瞬时冷负荷- 3 -2.1.3外玻璃窗瞬变传热引起的冷负荷- 4 -2.1.4透过玻璃窗的日射得热引起的冷负荷- 4 -2.2设备散热形成的冷负荷-4-2.3照明散热形成的冷负荷-5-2.4人体散热形成的冷负荷-5-2.5新风冷负荷-6-3 空调方案的确定- 9 -3.1空调方案的分类-9-3.1.1按空气处理设备的集中程度分为- 9 -3.1.2按承担室负荷所用的介质分为- 9 -3.2空调方案的比较-9-3.3空调系统形式确定-12-4 确定风量、送风状态点及选型计算- 15 -4.1风机盘管加独立新风系统-15-4.1.1夏季室新风量的确定- 15 -4.1.2新风处理状态的确定,总风量及风机盘管风量的确定- 17 -4.1.3风机盘管选型- 19 -4.1.4新风机组的选型- 19 -4.2全空气系统-21-5 风管水力计算- 23 -6 水管水力计算- 26 -6.1水系统形式的分类-26-6.1.1按管道数目分- 26 -6.1.2开式和闭式- 26 -6.1.3按环路分- 26 -6.1.4按流量来分- 26 -6.2水系统形式的确定-27-6.2.1计算基本公式:- 27 -6.2.2凝结水管路系统的设计- 27 -6.3水力计算方法-28-7 冷冻站的设计- 33 -7.1制冷机组的选择-33-7.1.1 各种制冷机的优缺点比较表- 33 -7.1.2制冷机的性能系数(COP)- 34 - 7.2冷却塔的选择-36-7.3分集水器的选择-37-7.4膨胀水箱的选择-37-7.5冷冻水泵的选择-38-7.6冷却水泵的选择-39-7.7补水泵的选择-39-8 结论- 40 -参考文献- 41 -致- 42 -1 工程概况1.1 原始资料惠新大厦是一个办公建筑。
该办公楼地下一层为中央空调机房及停车场,地上一~十层为办公楼。
冷却塔设于楼顶。
每层高4m,总建筑高度40m ,建筑面积21000m ²。
1.2 计算参数1.2.1基本气象参数地理位置:省 位置: 北纬34.71 东经:113.651.2.2室外计算参数夏季参数大气压: 99170.00Pa 室外计算干球温度: 35.6.00℃ 空调日平均计算温度: 30.80 ℃ 计算日较差: 9.2℃ 室外湿球温度: 27.40 ℃ 室外平均风速: 2.60m/s冬季参数大气压: 101280.0pa 空调计算温度: -5.000℃室外相对湿度: 60.00 % 室外平均风速: 4.300m/s1.2.3室设计参数1. 冬季室参数值:g t =20℃,Ф=50%,v ≯0.2m/s2. 夏季室参数值:g t =26℃,Ф=60%,v ≯0.3m/s1.3 动力资料:1.冷源:冷水机组进水温度7℃,回水温度12℃,温差t =5℃2.热源:城市热网3.水源:城市自来水4.电源:220/380v交流电1.4土建资料1.外墙体:根据建筑条件图,按《暖通空调.动力》选择I型墙体,370mm厚,传热系数0.78w/m2. ℃.2. 墙体:δ=240mm红砖抹灰3. 屋面:传热系数0.6 w/m2. ℃.4.地面:采用石铺地(非保温地面)5.门窗:窗玻璃采用6+6双层有色玻璃,无外遮阳,办公室遮阳类型为浅蓝布帘,双层钢窗有效面积系数0.756. 层高:4.0m2 负荷计算2.1 围护结构瞬变传热形成冷负荷的计算方法2.1.1外墙和屋面瞬变传热引起的冷负荷在日射和室外气温综合作用下,外墙和屋面瞬变传热引起的逐时冷负荷可按下式计算:s r K LQ -∆∂=t 1W (公式2.1-1) 式中:LQ1——外墙和屋面瞬变传热引起的逐时冷负荷,W ;F ——外墙和屋面的面积,㎡;K ——外墙和屋面的传热系数,W/(㎡·℃);τ——计算时间,h ;ε——维护结构表面受到周期为24小时谐性温度波作用,温度波传到表面的时间延迟,h ;τ-ε——温度波的作用时间,即温度波作用于维护结构表面的时间,h ; △t ετ-——作用时刻下,维护结构的冷负荷计算温差,℃;2.1.2墙,楼板等室传热维护结构形成的瞬时冷负荷当空调房间的温度与相邻非空调房间的温度大于3℃时,要考虑由维护结构的温差传热对空调房间形成的瞬时冷负荷,可按如下传热公式计算:LQ 2=F ·K ·(t l s - t n ) W (公式2.1-2) 式中:F ——维护结构的传热面积,m ²;K ——维护结构的传热系数,W /( m ²·k) ;t n ——夏季空调房间室设计温度,℃;t l s ——相邻非空调房间的平均计算温度,℃ 。
其中t'l s = t + t l s ℃ (公式2.1-3) 式中:t ——夏季空调房间室外计算日平均温度,℃;t l s ——相邻非空调房间的平均计算温度与夏季空调房间室外计算日平均温度的差值,当相邻散热量很少(如走廊)时, t l s 取3 ℃,;当相邻散热量在23~116W /m 2时,t ls 取5 ℃。
2.1.3外玻璃窗瞬变传热引起的冷负荷在室外温差的作用下,玻璃窗瞬变热形成的冷负荷可按下式计算: LQ 3=F ·K ·△t τ W (公式2.1-4) 式中:F ——外玻璃窗面积,m ²;K ——玻璃的传热系数,W /( m ²·k) ;△t τ——计算时刻的负荷温差,℃;2.1.4透过玻璃窗的日射得热引起的冷负荷透过玻璃窗进入室的日射得热形成的逐时冷负荷按下式计算: LQ 4=F ·C Z ·g x ·d x ·τ.j J W (公式2.1-5) 式中:F ——玻璃窗的面积;C Z ——玻璃窗的综合遮挡系数C Z =C s ·C n ;其中,C s —— 玻璃窗的遮挡系数,本设计中,C s =0.86; C n —— 窗遮阳设施的遮阳系数,本设计中, C n =0.6;g x ——窗的有效面积系数;单层钢窗,双层钢窗0.75;单层木窗0.7,双层木窗0.6;d x ——地点修正系数;τ.j J ——计算时刻时,透过单层窗口面积的太阳辐射热形成的冷负荷,简称负荷强度,W/m 2;2.2 设备散热形成的冷负荷设备和用具显热形成的冷负荷按下式计算:LQ=QC LQ W (公式2.2-1) 式中:LQ ——设备和用具形成的冷负荷,W ;Qq ——设备和用具的实际显热散热量,W ;CLQ ——设备和用具显热散热冷负荷系数;如果空调系纙不连续运行,则CLQ =1.02.3照明散热形成的冷负荷和照明灯具的类型和安装方式的不同,其冷负荷计算式分类为白炽灯:LQ5 =1000·N·CLQ W (公式2.3-1) 荧光灯:LQ5 =1000·n1·n2·N·CLQ W (公式2.3-2) 式中:LQ5——灯具散热形成的冷负荷,W;N——照明灯具所需功率,KW;n1——镇流器消耗功率系数,当明装荧光灯的镇流器装在空调房间时,取n1=1.2;当暗装荧光灯镇流器装设在顶棚时,可取n1=1.0;本设计取n1=1.0;n2——灯罩隔热系数,当荧光灯上部穿有小孔(下部为玻璃板),可利用自然通风散热与顶棚时,取n2=0.5~0.8;而荧光灯罩无通风孔时,取n2=0.6~0.8;本设计取n2=0.6;CLQ——照明散热冷负荷系数。