摄像机GCHX553中文说明书15页PPT
HAT553V中文说明书
HAT552_HAT553英文说明书
HAT552/HAT553DUAL POWER ATS CONTROLLER USER MANUALAll rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.Applications for the copyright holder’s written permission to reproduce any part of this publication should be addressed to Smartgen T echnology at the address above.Any reference to trademarked product names used within this publication is owned by their respective companies.Smartgen Technology reserves the right to change the contents of this document without prior notice.CONTENT1 OVERVIEW (4)2 MODEL FUNCTION COMPARISON (4)3 PERFORMANCE AND CHARACTERISTICS (5)4 SPECIFICATION (6)5 MEASURED AND DISPLAYED DATA (7)6 OPERATING (8)6.1 OPERATION PANEL (8)6.2 INDICATOR DESCRIPTION (9)6.3 KEY FUNCTION DESCRIPTION (9)7 LCD DISPLAY (10)7.1 MAIN SCREEN (10)7.2 SECOND LEVEL INTERFACE (10)7.3 STATUS DESCRIPTION (11)7.4 MAIN MENU (13)8 GENSET START/STOP OPERATIONS (14)8.1 MANUAL START/STOP (14)8.2 AUTO START/STOP (14)9 PARAMETER CONFIGURATION (15)9.1 ILLUSTRATION (15)9.2 PARAMETER CONFIGURATION TABLE (15)9.1 DIGITAL INPUT/OUTPUT FUNCTION DESCRIPTION (19)10 EVENT LOG (21)11 SWITCH OPERATION RUNNING (22)11.1 MANUAL OPERATION RUNNING (22)11.2 AUTO OPERATION RUNNING (22)11.3 AUXILIARY CONTACT FEEDBACK INPUT OF SWITCH OPEN (26)12 COMMUNICATION CONFIGURATION AND CONNECTION (26)12.1 ILLUSTRATION (26)12.2 RS485 COMMUNICATION PORT (26)12.3 USB COMMUNICATION PORT (26)13 DEFINITION OF CONNECTING TERMINALS (27)13.1 DESCRIPTION OF CONNECTING TERMINALS (27)13.2 DESCRIPTION OF CONTROLLER SUPPLY (29)13.3 DESCRIPTION OF RS485 CONNECTION (29)14 TYPICAL WIRING DIAGRAM (30)15 INSTALLATION (34)16 FAULT FINDING (35)1 OVERVIEWHAT552/HAT553 dual power ATS controller is a dual power transfer module integrated with configurable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking together, which realizes automation for measuring and control process, reducing artificial operation mistakes. It is the ideal product for dual power transfer. HAT552 is applicable for non-breaking switches, while HAT553 is applicable for non-breaking, one-breaking, and two-breaking switches.HAT552/HAT553dual power ATS controller is made with the microprocessor in the core, which can precisely measure 2-channel 3-phase voltages, make correct judgment and control outputs for occurred voltage abnormal (over voltage, under voltage, loss of phase, over frequency, under frequency, reverse phase sequence). It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building etc.2 MODEL FUNCTION COMPARISON3 PERFORMANCE AND CHARACTERISTICS—System type can be set to: Mains - Generator, Generator - Mains, Mains - Mains;—132x64 LCD with backlight, optional Chinese and English display, push-button operation; —Measure and display 2-channel 3 phase voltage, frequency and phase sequence;—Display of A power/B power accumulated close times;—Display of present continuous power supply time and A power/B power accumulated power supply time;—Over/under voltage, loss of phase, reverse phase sequence, over/under frequency protection function;—Auto/Manual mode transfer function: in manual mode, user can control the switch to close or open; —All parameters are configurable. password verification is used to prevent non-professional error operations;—Commissioning can be done on site manually to execute genset start/stop operations; —Switch Re-closing function is fitted;—Breaker close output can be set to pulse or steady output;—2-channel N wire isolated design;—Real-time clock (RTC) display, and event log function, which can record 50 data cyclically. —Scheduled start & stop generator function: running once monthly/weekly, and onload/offload running are configurable;—AC supply power can be phase voltage (L, N), supply range: (177-277)V;— 1 RS485 isolated communication port, has "remote control, remote measuring, remote communication, remote adjusting" function with ModBus-RTU communication protocol; genset start, genset stop, ATS close/open can be controlled remotely;—Suitable for various AC system types (3 phase 4-wire, single-phase 2-wire, and 2-phase 3-wire); —Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.4 SPECIFICATION5 MEASURED AND DISPLAYED DATA6 OPERATING6.1 OPERATION PANELFig. 1 HAT552 Front PanelFig. 2 HAT553 Front Panel6.2 INDICATOR DESCRIPTIONTable 5 Indicator DescriptionIndicator Name Indicator DescriptionAlarm Indicator Slow flashing for warning alarms ( 1time per second);Fast flashing for fault alarms ( 5 times per second)Auto Mode Indicator Light on when current is Auto mode;Manual Mode Indicator Light on when current is Manual mode;A Power Indicator Always light on when A AC power is normal; flashing when it isabnormal; light off when it is outage.A Power Close Status Indicator Light on when A power switch auxiliary contact is active; light offwhen it is inactive;B Power Close Status Indicator Light on when B power switch auxiliary contact is active; light offwhen it is inactive;B Power Indicator Always light on when A AC power is normal; flashing when it isabnormal; light off when it is outage.6.3 KEY FUNCTION DESCRIPTIONKey Function DescriptionManual Key Transfer to Manual mode (HAT552);Auto Key Transfer to Auto mode (HAT552);Manual/Auto Key Transfer to Manual or Auto mode (HAT553);A Close Key Active in manual mode;Press and A power switch closes; load is supplied by A power;Open Key Active in manual mode;Press and load is disconnected (HAT553);B Close Key Active in manual mode;Press and B power switch closes; load is supplied by B power;Set/Confirm In main screen, press and it enters menu interface;After entering menu interface, confirm key can move the cursor and confirm the set information;Down/Lamp T est Key In main screen, press and scroll down the screen display;After entering menu interface, it can move down the cursor or decrease the value where the cursor is;In main screen, pressing longer is lamp test; when lamp test is done, LCD backlight is illuminated, LCD displays all dark and all LED indicators on the panel are illuminated.NOTE: Press and simultaneously to set backlight on always; Again press both simultaneously or power on afresh to cancel backlight on always.7 LCD DISPLAY7.1 MAIN SCREEN7.2 SECOND LEVEL INTERFACE7.3 STATUS DESCRIPTIONWhen controller detects warning alarm, warning alarm becomes active, alarm indicator will slow flashes (1 time per second), and when alarm disappears, alarm indicator will extinguish. Warning alarm isn't latched.When controller detects fault alarm, fault alarm becomes active, alarm indicator will quick flash (5 times per second). Fault alarm is latched, and it disappears until user resets it manually.When reminder information is active, it displays for 2s and then it disappears.No. Item Description1 Press Reset Alarm The reminder for manual transfer to auto mode before alarm clear asfault alarm occurs.2 A Already Close Set it to one breaking or two breakings; reminder information forpressing A power close key as A power is closed. (HAT553)3 B Already Close Set it to one breaking or two breakings; reminder information forpressing B power close key as B power is closed. (HAT553)4 Already Open Reminder information for pressing open key as load is disconnected.(HAT553)No. Item Description1 Start Inhibit Genset start inhibit input is active.2 Remote Gen On Load Remote start onload input is active.3 Remote Gen Off Load Remote start offload input is active.4 Gen Start Mains NG Start when Mains is abnormal.5 Auto Mode Current is in auto mode.6 Manual Mode Current is in manual mode.7.4 MAIN MENUIn main interface, press key to enter main menu screen.1. Exit2. Parameters Set3. History Record4. Auto Trans./Restore5. T est Genset6. Date & Time Set7. Language8. T otal Information9. Information Press Down key and select different parameter line (backlit) and then press Confirm key, to enter related interface.NOTE: Password is needed for entering parameter settings, and default password is "01234"; Operators can change the password to prevent others changing controller configurations randomly. Please remember clearly after the change, or it is forgotten, please contact our company personnel.8 GENSET START/STOP OPERATIONS8.1 MANUAL START/STOP8.1.1 PANEL START/STOPIn main screen, press Set/Confirm key to enter main menu interface; select "5. Test Genset" to enter manual start operation screen.When system type is "A Mains B Gen, A Gen B Mains, A Mains B Mains", the below operation interfaceGenset Start: Control genset start signal output, which is to control genset start;8.1.2 REMOTE COMMUNICATION START/STOPThrough RS485 port and by using Modbus protocol control, remote start or remote stop commands can be issued.Remote Stop: Disconnect the outputted genset start signal, which is to control genset stop;Remote Start: Control genset start signal output, which is to control genset start;8.2 AUTO START/STOP8.2.1 START REQUIREMENTS8.2.1.1 INPUT PORT STARTSet "Remote Start Onload" or "Remote Start Offload" for configurable input ports, and they are cannot be set at the same time.Remote Start Onload: Genset start outputs, when generating is Ok, GB closes; when it is inactive, disconnect genset start output signal;Remote Start Offload: Genset start outputs, when mains is Ok, MB closes; when it is inactive, disconnect genset start output signal;8.2.1.2 MAINS ABNORMAL STARTWhen Mains is abnormal, genset start outputs; when generating is Ok, GB closes;8.2.2 SCHEDULED STARTWhen Scheduled Gen Start is enabled, user can set scheduled start time; Controller will issue start signal when the time is up; when the scheduled start delay time is over start signal is disconnected. Scheduled start can be set to onload or offload.Scheduled Start Onload: genset start outputs, when generating is Ok, GB closes;Scheduled Start Offload: genset start outputs, when Mains is Ok, MB closes;Scheduled Start Cyclical Time can be set to Start Monthly/Weekly/Daily.Start Monthly: Which month to start, start date and time can be set;Start Weekly: Start at the same time of several days in a week can be set; for example, from Monday to Friday start at 8:00 every day and last for 10 hours.Start Daily: Start at the same time for each day can be set.9 PARAMETER CONFIGURATION9.1 ILLUSTRATIONIn the first page of the main screen, press key to enter menu screen; select "Parameters Set" and press Confirm key to confirm and enter parameter setting password check interface. Input correct password and it will enter parameter main interface. If password is wrong, then it directly returns to maininterface. Default password is 01234. In parameter setting page, press longer to directly exit from this screen and return to main screen.9.2 PARAMETER CONFIGURATION TABLENo. Item Range Default DescriptionAC Setting1 A Available Delay (0-3600)s 10 The check time from A power abnormal to normal.2 A Unavailable Delay (0-3600)s 5 The check time from A power normal to abnormal.3 B Available Delay (0-3600)s 10 The check time from B power abnormal to normal.4 B Unavailable Delay (0-3600)s5 The check time from B power normal to abnormal.5 Set Master (0-1) 0 0: A Master 1: B Master6 System Type Set (0-2) 0 0: A Mains B Gen 1: A Gen B Mains 2: A Mains B Mains7 AC System (0-3) 0 0: 3-Phase, 4-Wire1: 3-Phase, 3-Wire2: 2-Phase, 3-Wire3: Single Phase, 2-WireSpecial custom is needed for 3 Phase 3 Wire.8 Rated Voltage (0~30000)V 220 Rated voltage value for AC system.9 Over Volt Set (0~1) 1 0: Disable 1: Enable10 Over Volt Value (0~200)% 120 Voltage upper limit; abnormal when it is over upper limit.11 Over Volt Return (0~200)% 115 Voltage upper limit return value; normal when it is lower than return value.12 Under Volt Set (0~1) 1 0: Disable 1: Enable13 Under Volt Value (0~200)% 80 Voltage lower limit; abnormal when it is lower than this limit.1: Fault8 Auto Trans/Restore (0-1) 1 0: Auto Trans/Non Restore 1: Auto Trans/Restore9 Each Backup (0-1) 1 0: Inactive 1: Active10 Open Input Enable (0~1) 0 0: Disable1: Enable (HAT553)If this is not connected, please set it to Disable.11 No Open TransferEnable(0~1) 00: Disable1: EnableWhen it is set to Enable, controller directlytransfers to the other circuit from one circuit;and there is not open control output in thetransfer process. (HAT553)Genset Setting1 Genset Start Delay (0~9999)s 1 Delay starts when genset prepares to start; when delay is over, controller issues genset start signal.2 Genset Stop Delay (0~9999)s 5 Delay starts when genset prepares to stop; when delay is over, controller disconnects genset start signal.Scheduled Start/Stop Setting1 Schedule Gen Enable (0~1) 0 0: Disable 1: Enable2 Schedule Load (0~1) 0 0: Off Load 1: On Load3 Schedule Period (0~2) 0 0: Monthly 1: Weekly 2: Daily4 Schedule Monthly Month January February March April May JuneJuly August September October November December5 Schedule Date (1~31) 1 Date for genset start for each month.6 Schedule Weekly Week Sunday Monday Tuesday Wednesday Thursday Friday Saturday7 Schedule Hours (0~23)h 0Time for scheduled start.8 Schedule Minutes (0~59)min 09 Schedule Work Time (0~30000)min 30 Lasting time for scheduled start running. Programmable Input Setting1 Digital Input 1 (0~20) 0 Not Used2 Active Type (0~1) 0 0: Close to Activate 1: Open to Activate9.1 DIGITAL INPUT/OUTPUT FUNCTION DESCRIPTION 9.3.1 INPUT PORT FUNCTION DESCRIPTION9.3.2 OUTPUT PORT FUNCTION DESCRIPTION10 EVENT LOGIn the first page of the main interface, press key, and enter menu page. Select "Event Log", andthen select to confirm. In this way Event Log interface is entered.Each item of Event Log contents includes:Date and time at recording;Type of record;Event of record;A power status;B power status;A power 3-phase voltage;B power 3-phase voltage;A power frequency;B power frequency;Event log can be recorded up to max. 50 items. The first one is the newest. Users can check each item via Down key. When recorded items are over 50, new item will cover the newest record.Record type includes: Action Event, Warn Event, Fault Event. Fault events are all fault alarms, warn events are all warning alarms.No. Action Event Description1 Closing A Record when A power close is outputted;2 Closing B Record when B power close is outputted;3 Opening A Record when A power open is outputted; (HAT553)4 Opening B Record when B power open is outputted; (HAT553)5 Simult. Dual Close Record when A power and B power takes load simultaneously;6 Genset Start Record when genset start signal is outputted;7 Genset Stop Record when genset start signal is disconnected;8 Auto Mode Record when it is transferred to Auto mode;9 Manual Mode Record when it is transferred to Manual mode;11 SWITCH OPERATION RUNNING11.1 MANUAL OPERATION RUNNINGPress manual/auto transfer key , and manual status indicator is illuminated; Controller is in manual status (HAT553).Press manual key , and manual status indicator is illuminated; Controller is in manual status (HAT552).After the switch transfer key is pressed, switch transfers immediately; In the process of transferring, the related indicator flashes; When the switch is transferred to the position, the related indicator is illuminated always.Icon Key Name Function DescriptionA Power Close Press and if load is in open status, A power closes, and load issupplied by A power.B Power Close Press and if load is in open status, B power closes, and load issupplied by B power.Open Key Press and load is disconnected (HAT553).11.2 AUTO OPERATION RUNNINGPress manual/auto transfer key , and auto status indicator is illuminated; Controller is in auto status (HAT553).Press auto key , auto status indicator is illuminated; Controller is in auto status (HAT552).In auto mode, controller will transfer switch based on the status of A power and B power, transfer priority and auto trans./restore status to ensure supply for load. The following illustrates control logics by the example of "A power master" and "A Mains B Gen".11.2.1 AUTO TRANS./RESTOREWhen Auto Trans./Restore is set, A power is master; if A power is normal, then A power closes; if A power is abnormal, B power is normal, then A power opens, B power closes; if A power recovers normal, then B power opens, A power closes.Fig. 3 Auto Trans./Restore Flow Chart11.2.2 AUTO TRANS./NON RESTORE (ACTIVE FOR MUTUAL BACKUP)When Auto Trans./Non Restore is set, and Mutual Backup is active, A power is master. If A power is normal, then A power closes; if A power is abnormal, B power is normal, then A power opens, and B power closes; If A power recovers normal, B power is normal, then switch keeps at B power close status.Fig. 4 Auto Trans./Restore (Active for Mutual Backup) Flow Chart11.2.3 AUTO TRANS./NON RESTORE (ACTIVE FOR MUTUAL BACKUP)When Auto Trans./Non Restore is set, and Mutual Backup is inactive, A power is master. If A power is normal, and A power closes, when A power is abnormal, B power is normal, then A power opens, B power closes; if A power recovers normal, then switch keeps at B power close status; when B power is abnormal, B power opens; even through A power is normal, A power doesn't close.Fig. 5 Auto Trans./Non Restore (Active for Mutual Backup) Flow ChartNOTE: Master power (A power) close needs to transfer to manual mode and by button operation close, otherwise in auto mode, switch only transfers between open and backup power (B power) position.11.2.4 NONE OPEN TRANSFERWhen none open transfer is enabled, controller will not execute open operation. Detailed setting method: in parameter setting interface, enter "switch setting" interface, find "None Open Transfer" Enable and set it enabled. The following illustrates control logics by the example of "A power master", "A Mains B Gen".A power is normal, A power closes; When A power is abnormal,B power is normal, controller issues B power close order; switch directly transfers from A power loading to B power loading. A power open steps in the middle are omitted.NOTE: this function is only suitable for switches with breakings and switches allowing to transfer directly from A power loading to B power loading (HAT553).11.3 AUXILIARY CONTACT FEEDBACK INPUT OF SWITCH OPENIf switch needs to access to open feedback input, please firstly set open input enabled. Detailed setting method: in parameter setting interface enter "switch setting" interface, find "open input enable" and set it enabled; Then set auxiliary input port 1 "19: Open IN", when auxiliary input 1 detects low electrical level, open input is active.During the transfer process, if failed to close of A power occurs, A power switch won't execute close action, B power is Ok, and B power close is executed. If failed to open occurs, controller won't execute switch close/open actions.12 COMMUNICATION CONFIGURATION AND CONNECTION12.1 ILLUSTRATIONHAT553_HAT552 dual power transfer controller has RS485 communication port, USB communication port. Between them RS485 communication port allows to connect LAN of open structure. Communication port applies Modbus communication protocol, by the running software on PC or data collecting system, to provide a simple and practical dual power transfer management method of factories, telecommunication, industries and civil buildings, realizing "remote control, remote measuring, remote communicating" functions of dual power monitoring.For detailed information please refer to HAT552_HAT553 Communication Protocol.12.2 RS485 COMMUNICATION PORTCommunication Protocol: Modbus-RTUCommunication ParametersModule Address 1(Range: 1-254)Baud Rate 9600bps (2400/4800/9600/19200bps)Data Bit 8 bitParity bit None (None, Odd, Even)Stop bit 2-bits (1 bit or 2 bits)12.3 USB COMMUNICATION PORTD-form USB communication port, can be used to connect PC test software and configure parameters and at the same time it can be used for module program upgrade.Fig. 6 USB Connecting Diagram13 DEFINITION OF CONNECTING TERMINALS13.1 DESCRIPTION OF CONNECTING TERMINALSFig. 7 Controller Back Panel13.2 DESCRIPTION OF CONTROLLER SUPPLYController is AC supplied by the two AC sampling terminals directly.Fig. 8 AC Supply Diagram13.3 DESCRIPTION OF RS485 CONNECTIONConnecting of RS485 and Adapter is like below:Fig. 9 RS485 Connecting Diagram14 TYPICAL WIRING DIAGRAMFig. 10 SGQ-N/T Application DiagramA Part of Parameter SettingSwitch Type Setting No breaking (available for HAT553; not available for HAT552)Fig. 11 FEITENG Application DiagramA Part of Parameter Setting Switch Type Setting Two breakings (HAT553)Fig. 12 Connector Application DiagramA Part of Parameter SettingSwitch Type Setting Two breakings (HAT553)Close Time Set it to 0 (HAT553)Switch Transfer Interval 10s (HAT553, set it according to factual occasions)Fig. 13 Breaker (ACB) Application DiagramTable 26 Related SettingsA Part of Parameter SettingSwitch Type Setting Two breakings (HAT553)NOTE: Above diagrams are only examples; Users shall connect wires based on the real occasions.Attached illustration for LO, NO connection inside controller:HAT553/HAT552 controller has automatic transfer function of ATS power supply inside. Only if one voltage of A power and B power is normal, by transfer between N/O contact and N/C contact of intermediate relay 1 and intermediate relay 2 ensure ATS power supply normal. The output is LO, NO. Output value is LN voltage value of A power or LN voltage value of B power. Internal wiring is as below: R1, N1 is R, AN input of A power; R2, N2 is R, BN input of B power.Fig. 14 Internal LO, NO Connection15 INSTALLATIONThe controller is designed by panel installation method, and is fixed by clips for installation.Unit: mmFig. 15 Overall Dimensions and Cutout16 FAULT FINDINGTable 27 Fault FindingSymptom Possible SolutionsController no response with power Check DC supply voltage; Check DC fuse;Check AC power;RS485 communication abnormal Check whether RS485 positive and negative are correctly connected; Check RS485 transformer is normal or not;Check module address in the parameter settings is correct or not;If above methods are unsuccessful, please try to parallel in 120Ω resistor between A and B of controller RS485.Auxiliary Output Error Check auxiliary output connecting wire, pay attention to N/O N/C points; Check output port setting function and output type in parameter settings;Auxiliary Input Abnormal Check whether aux. input port is GND connected when it’s active, and it shall hung up when it is inactive.(NOTE: The input port will be possibly destroyed when connected with voltage.) Check the input setting function of parameter settings and active type.Switch Transfer Abnormal Check ATS.Check the connection wirings between the controller and the ATS. Check switch related parameter settings.Genset Start Control Abnormal Check system type settings.Check output function settings and output type. Check start/stop function settings of all items._______________________________________。
Panasonic 数码摄像机 NV-GS11GC GK NV-GS15GC GK 说明书
使用说明书Operating Instructions Инструкция по эксплуатации数码摄像机Digital Video CameraModel No.NV-GS11GC/GKNV-GS15GC/GK使用前,请完整阅读本说明书。
Before use, please read these instructions completely.Перед пользованием прочтите, пожалуйста, эту инструкциюполностью.LSQT0781A安全注意事项ª请仔细阅读使用说明书并正确使用摄像机。
≥由于未按照本使用说明书中说明的操作步骤进行操作,而导致的损害或材料损坏由用户负责。
使用说明书≥这些使用说明书适用于 NV-GS11型和NV-GS15型。
≥这些使用说明书中所用的图解说明的是NV-GS15型,但部分的解释涉及不同的型号。
≥依据型号,某些功能不可用。
试用摄像机。
在记录第一个重要事件前,首先要试用一下摄像机,以保证其录制性能与各种功能能够正常使用。
制造商对于录制内容的损失不负任何责任。
制造商对于因摄像机、其附件或磁带的故障或缺陷造成的任何损失概不负责。
请严格遵守版权法。
若非个人使用,复制先期录制的磁带、磁盘、其它出版物或播放材料都侵犯版权法。
即使是个人使用,也严禁复制某些特定材料。
≥摄像机使用了版权保护技术,并且被日本和美国的专利技术和知识产权所保护。
要想使用这些版权保护技术,必须得到Macrovision 公司的授权。
禁止分解或改装摄像机。
≥Windows 是美国Microsoft 公司的商标或注册商标。
≥SD 徽标是商标。
≥使用说明书中的所有其它公司和产品名称都是各个公司的商标或注册商标。
由于本设备使用时会变热,请在空气流通的地方进行操作,不要将此设备安置在狭窄的空间内,例如书柜或类似地方。
要降低起火、电击或产品损坏的危险,请勿将本设备暴露于雨中、潮湿、滴水或溅水的环境,并确保勿将盛满液体的物品(如花瓶)放在本设备上。
松下AJPX摄像机常用功能教程PPT课件
提高整个画面的宽容度 会议室 体育场 强光下的逆光拍摄
动态伽玛 (DRS)使用方法
23
第19页/共30页
快门同步扫描设置
SHTR/F.RATE拨盘按以下切换: SHUTTER(快门)→SYNCHRO SCAN(同步扫描 当SHUTTER设置为 SYNCHRO SCAN )→FRAME RATE(帧频选择 1080i或720模式下使用) →LOCK(锁住 ) →SHUTTER (快门)
AJ-PX298支持的AVC-ULTRA
视频格式?压缩格式?
2
第1页/共30页
AVC Ultra 编码家族支持
基于不同应用选择不同
家族
强调质量
200Mbps ps
100Mb
传统格式支持
强调效率
50Mbps 25Mbps 12Mbps 6Mbps 3.5Mbps 1.5Mbps 800Kbps
第2页/共30页
12
为了确认下变换为标清 后4:3的取景范围
设置寻像器的4:3安全框
4:3安全框
90%安全框
将长宽比对应框选择“打开”
第13页/共30页
4:3范围之外的黑色遮蔽 15:透明 0:黑色
13
设置辅助聚焦
按下FOCUS ASSIST按键,在 屏幕上显示辅助聚
焦功能
菜单显示设置中聚 焦状态条设定成 “打开”
第20页/共30页
LCD上的水平校正 仪
打开方法:
摄像 机左 右水 平提
摄像 机前 后水 平提
第21页/共30页
拍摄视频中显示时间戳
第22页/共30页
第23页/共30页
第24页/共30页
第25页/共30页
调整画面风格
H系列网络摄像机使用手册
1、 安装环境
, 远离高温的热源和环境;避免阳光直接照射; , 注意防水, 有水接触到设备时, 立即断电. , 避免在过于潮湿的环境使用, 请在参考的适用湿度范围(85%RH 以下)内使用。 , 避免在过热或过冷环境使用, 请在参考的适用温度范围(-10℃ ~ +50 ℃)内使用。 , 本机应水平安装或壁挂安装,避免安装在会剧烈震动的场所,勿将其它设备放于本机
3. IE浏览器观看操作 .......................................................................................................................10
3.1. 视频浏览 ...............................................................................................................................10 3.2. 视频设置 ............................................................................................................................... 11
上。
2、 运输与搬运
, 本机的包装经过抗震设计和实验,确保在运输过程中摄像机不会受到意外损坏,所以 在搬运本机时,最好使用原来的包装材料和纸箱;
, 避免在过冷、过热的场所间相互搬动摄像机,以免机器内部产生结露,影响机器的使 用寿命;
, 严禁带电搬动本机,否则会损坏主板;
注意:
博世 ZX55-IP 红外摄像机 说明书
ZX55‑IP 红外摄像机适用于长距离的、需要日/夜监控的重要室外应用场合。
ZX55‑IP 配备了 9‑90 毫米镜头、功能强大的 Black Diamond 红外照明技术以及用于智能视频分析 (IVA) 的强大处理器。
ZX55‑IP 还提供长达 300 米(1000 英尺)的夜视能力,因而可为长距离全天候监控应用场合提供无与伦比的性能。
为了有效监护重要资产和长距离的延伸周界,ZX55‑IP 采用了9‑90 毫米变焦镜头。
窄角或广角画面均可用于首选视场,系统的鉴定距离长达 100 米(330 英尺),并且提供区分面部特征的能力。
此外,这一高水平的成像技术比标准 IP 摄像机占用更少的带宽,对网络性能影响较小。
适合各种气候条件的 ZX55‑IP 配备顶部和侧面遮阳罩,可在摄像机受到强烈阳光直射的应用场合中反射热量。
内置通风口还允许气流直接冷却高性能系统并降低内部温度。
ZX55‑IP 非常适合如强制布防、周界监控和重要资产监护等重要应用场合。
基本功能智能视频分析 (IVA)•板载视频内容分析功能可以监视场景活动并标记报警等用户定义的事件(需要额外的许可证)Black Diamond 红外照明技术•Black Diamond 技术消除了过亮的前景和曝光不足的背景•扩展的夜晚红外成像距离长达 300 米(1000 英尺)•减少图像信噪,启用更佳的压缩技术,因此降低了比特率,使网络性能更加稳定•启用高效的夜间视频分析性能适合所有天气条件的坚固防护罩结构•经过现场验证的 NEMA4X 全天候防护罩•方便布线的墙壁支架•专用摄像机机柜,轻松进行光学调节•顶部和侧面遮阳罩实现优异的热变形性能•设计能够承受 250 千米/小时 (155 mph) 的风荷载高性能视频编码器•MPEG-4 和 MJPEG 视频流每秒 30 幅全清晰度图像•三视频流既能实现高清晰度查看,又能进行高效存储(反之亦然)•支持各种 VMS 和 NVR 解决方案高性能的精密光学元件•540 电视线高清日夜型 CCD 提供逼真的白天色彩和出色的夜视能力•9-90 毫米红外校正镜头提供长达 300 米(1000 英尺)的大范围 DCRI 监控,实现最广泛的成像功能•红外校正镜头可消除焦距偏离和红外流失ZX55-IP 红外摄像机▶高性能日夜两用摄像机,轻松进行周界监控和重要资产监护▶集成智能视频分析 (IVA) 功能▶Black Diamond 红外照明技术▶长距离分类和识别等级性能▶适合所有天气条件的坚固防护罩结构▶Bosch BVIP MPEG-4 视频编码器2 | ZX55-IP 红外摄像机安装/配置尺寸mm (in)mm (in)技术规格视频ZX55‑IP 红外摄像机感应器1/3 英寸日/夜 CCD有效像素(水平 x 垂直)NTSC:768 x 494有效像素(水平 x 垂直)PAL:752 x 582清晰度彩色 540 电视线 / 黑白 540 电视线白昼模式灵敏度0.02 lux,F1.4夜晚模式灵敏度0 lux - 可在完全漆黑的环境下工作镜头红外校正,9 - 90 毫米手动变焦自动光圈,DC 驱动伽马0.45视频输出 1 Vpp,75 欧姆日夜切换光电元件控制,自动光电元件自动,可调灵敏度照明设备Black Diamond 红外 LED 阵列,强度可调波长850 纳米(半隐蔽)或 *940 纳米(全隐蔽)*(与 850 纳米时的标准距离相比,940 纳米的距离损失为50-60%)范围规格夜视红外水平视场(10° 光束角度)探测300 米(1000 英尺)45 米(150 英尺)分类250 米(820 英尺)35 米(120 英尺)识别150 米(500 英尺)25 米(80 英尺)鉴定100 米(330 英尺)15 米(50 英尺)接口以太网10/100 Base-T RJ45模拟PAL 或 NTSC BNCIP协议Telnet、RTP、HTTP(S)、ARP、TCP、UDP、IP、ICMP、DHCP、IGMPv2/v3、SNMP、802.1x压缩MPEG-4 SP 和 MJPEG,速度达每秒 30 帧,可选三视频流帧速率1-30 FPS,可编程(全动态)带宽9.6 Kbps 至 6 Mbps,可配置ZX55-IP 红外摄像机 | 3清晰度和帧速率PAL(水平 x 垂直)NTSC(水平 x 垂直)4CIF:25/30 IPS704 x 576704 x 4802CIF:25/30 IPS704 x 288704 x 240半 D1:25/30 IPS352 x 576352 x 480CIF:25/30 IPS352 x 288352 x 240QCIF:25/30 IPS176 x 144176 x 120电气指标电压12 至 24 VDC 或 VAC功耗最大 58 瓦机械指标外壳模压铝材/聚碳酸酯/ABS 合金外饰阳极电镀外壳/丙烯酸聚氨酯涂漆,用于遮阳视窗注模 2.5 毫米视窗安装架随附重载电缆管理支架尺寸(高 x 宽 x 厚)296 x 236 x 377 毫米(12 x 9 x 15 英寸)重量8.6 千克(19 磅)环境要求工作温度范围-50 ºC 至 +50 ºC(-58 ºF 至 +122 ºF)风荷载能够承受 250 千米/小时 (155 mph) 的风荷载环境经认证符合 CSA 类型 4X 室外天气等级。
GCHX503中英文混合说明书课件
调整和操作
Fig 1. 侧视图
Fig 2. 后视图
示意图
各个部分的功能及说明: 1. 按键“1” 和 “2” In line lock mode, zero crossing point can be adjusted by pressing these buttons. In MWB mode, manual white balance can be adjusted by pressing these buttons. 2.按键“3” In One push lock mode, white balance can be aligned by pressing this button. When this button is released, white balance is locked.
“10”
“11”
8
LENS
VSD
DC
LL
INT
AC24
LEVEL
V-PH
VIDEO
“8”
“9”
GND
“1”
“2”
“3”
“4”
“5”
“6”
“7”
UP
DOWN
PUSH LOCK
0
0
0
0
Flange back focus adjustment 1. In case of fixed focus lens a. Loosen the locking ring and set the focus ring of lens to infinity ( ∞ ) . b. Tune the mount ring to get a clear picture( distance from camera to object is more than 23m) and fasten the locking ring. 2. In case of zoom lens a. Loosen the locking ring and set the lens to the maximum telephoto position. Then turn the focus ring to focus. ☞ in the case of Auto iris lens, shoot a comparatively dark object or reduce the ambient light so that the Iris is fully open. b. Set the lens to its maximum wide angle position, and set the focus. c. Repeat step a and b, until the difference between focusing position a and b is smallest. D. When the best focusing point is found, fasten the locking ring.
索尼说明
关于语言设定
• 操作步骤的插图将使用以各种本地语 言显示的画面显示。如果需要,请在使 用摄像机之前更改画面显示语言(第 10 页)。
关于录制
• 开始录制之前,先测试录制功能,以保 证录制的图像和声音没有问题。
电池电量不足,录制 / 播放 将很快停止。
更换为充足电的电池,或者 给电池充电。
充电时间
对完全放电的电池组完全充电所需要的 近似时间 (分钟)。
电池组 NP-FH30 (随机提供) NP-FH50 NP-FH70 NP-FH100
充电时间
115
135 170 390
稍后,近似的可录制时间和电池信息将 显示约 7 秒钟。显示此信息时再按 DISP/ BATT INFO,可观看此电池信息最长达 20 秒钟。
复制 / 编辑
复制到卡带录像机或 DVD/HDD 录像机 ............................. 38
从卡带录像机等设备录制图像 (DCR-HC52E/HC54E)........... 40
使用电脑
用 Windows 电脑您能做些什么 (DCR-HC53E/54E) ............ 41 安装 “初次操作指南”和软件 (DCR-HC53E/54E) ............ 42 查看 “初次操作指南”(DCR-HC53E/ 54E) ....................... 44
Guide)”针对连接摄像机至电脑以及 使用随机提供的软件 (储存在随机提 供的 CD-ROM 中)
摄像机内可以使用的盒式录像带类 型
• 您可以使用带有
标志的小型 DV 盒
Hitachi CP-X5550 高清XGA分辨率LCD投影仪说明书
Key Features■ X GA 1024 x 768 resolution■ 5,800 ANSI lumens white/color output ■ 10000:1 contrast ratio■ 4,000 hours lamp life (Standard mode);6,000 hours lamp life (Eco mode)*■ E dge Blending & Warping ■ H DCR / Accentualizer /Image Optimizer■ C onvenient Networking / WirelessCapability■ S mart Device Control ■ H DMI-OutCP-X5550As part of Hitachi’s Collegiate Series, the CP-X5550 combines XGA 1024 x 768 resolution with super-bright 5,800 ANSI lumens white/color light output for a stunning visual achievement. It can transform classrooms,lecture halls, and auditoriums into true learning centers. The CP-X5550 is easily stackable which enables you to place one projector on top of another to project the same image from both onto a screen for added brightness. Incorporating Hitachi's leading-edge technology, the CP-X5550 features an image-enhancing combination of Accentualizer, High Dynamic Contrast Range (HDCR) and Image Optimizer, all of which contribute to the overall visual experience. Plus, Hitachi’s Intelligent Eco and Saver Modes with ImageCare combines optimal picture performance with maximum energy savings for a lower cost of ownership. For added peace of mind, Hitachi’s CP-X5550 is also backed by a generous warranty and our world-class service and support programs.HI0447-04/16-Rev.3All specifications subject to change without notice.3LCD and the 3LCD logo are registered trademarks of the Seiko Epson Corporation.iPad and iPhone are registered trademarks of Apple Inc., registered in the U.S. and other countries. ©2016 Hitachi America, Ltd. All Rights Reserved .UNIQUE FEATURES HDCR (High Dynamic Contrast Range)When average projectors are used in bright rooms, the darker colors of animage deteriorate and images become unclear. Using this function, blurred images caused by room lighting or outside light sources are corrected, andan effect similar to increasing contrast occurs. This results in clear imageseven in bright rooms.AccentualizerHitachi original technology makes pictures look more real by enhancing sharpness, gloss and shade to make pictures as clear as pictures on a flat-panel device. You can also adjust the effects by three levels according to your surroundings so that the colors of projected images are the actual colors of the objects they represent.Sharpness Gloss ShadeWarpingWarping is possible from your computer by using the specialized application. Projection is possible on spherical surfaces and surfaces with corners, as well as conventional flat screens.Edge BlendingProjectors are equipped with the Edge Blending function that achieves the seamless projection of one image using multiple projectors. The 5000 series comes with various blendingfunctions that meet the level users are looking for.Instant blending: Easily perform blending processing without the use of any special equipment.Automatic blending: Use a camera and quickly perform high precision blending processing automatically.Requires installation of a specialized application to your computer.Instant Blending Automatic BlendingDICOM ® Simulation ModeThe DICOM (Digital Imaging and Communications in Medicine) Simulation Mode projects grayscale images which approximate DICOM Part 14specifications. This mode is ideal for viewing grayscale medical images, such as X-rays, for training and educational purposes.The projectors have a DICOM (Digital Imaging and Communications inMedicine) Simulation Mode. This mode simulates the DICOM standard, which is a standard applicable to digital communications in medicine, and is useful for displaying medical images such as X-rays. These projectors are not medical devices and are not compliant with the DICOM standard, and neither the projector nor the DICOM Simulation Mode should beused for medical diagnosis. Comparison photos are simulations.enables you to display one image within another image. These functions are handy when you need to compare two sets of data or othermaterial.Image OptimizerThe Image Optimizer auto-matically adjusts HDCR and Accentualizer to improve visibility as lamp brightness dims over time.CP-X5550Right Side ProfileLeft Side ProfileStackableTop ViewFront View16101115131412163458HDMI Out Computer In HDMI 1 / MHL Audio In 1HDMI 2Monitor Out7. USB Type A (For Wireless)8. LAN9. Audio Out10. Remote Control Out 11. Remote Control In 12. AC Power13. Control (RS-232C)14. Video15. Audio in (L/R)16. Kensington Lock97Trade-Up Program。
Panasonic高清摄像头产品说明书
• 720p HD images up to 30 fps• Super high resolution at HD / 1,280 x 720 created by 2.4 Megapixel high sensitivity MOS image sensor• Multiple H.264 (High profile) streams and JPEG streams ensure simultaneous real time monitoring and high resolution recording by “UniPhier ®”, Panasonic’s proprietary System LSI platform.• Full frame (Up to 30 fps) transmission at 1,280 x 960 image size • 45x HD extra optical zoom at 1,280 x 720 (30x optical zoom) 90x extra optical zoom at 640x360 resolution with 12x digital zoom enabling 1080x zoom.• Super Dynamic and ABS (Adaptive Black Stretch) technologies deliver 128x wider dynamic range compared to conventional cameras.• Face Super Dynamic technology ensures clear face image.• High sensitivity with Day/Night (ICR*) function: 0.3 lx (Color), 0.04 lx (B/W) at F1.6 *ICR: IR Cut filter Removal• VIQS (Variable Image Quality on Specified area) technology allows the designated 2 areas to retain higher image quality while the excluded area will have a decreased image quality, which enables to use lower image file size and bit rate.VIQS can be set on preset position (1 to 8) and except preset.• Digital Noise Reduction: 3D-DNR ensures noise reduction in various conditions.• Progressive scan ensures clear images with less motion blur and no tearing even when the subject is moving.• Electronic sensitivity enhancement: Auto (Up to 16x) / OFF • Selectable light control modes:Outdoor scene / Indoor scene (50 Hz) / Indoor scene (60 Hz) / Fix shutter Indoor scene (50 Hz / 60 Hz): Flicker causedby fluorescent lightning will be automatically compensated.• 360 degrees endless Panning• Advanced auto tracking: The camera automatically pans and tilts to follow a moving subject and keep it in the center of the image.• PTZ control can be taken very smoothly on the user friendly GUI with 16 speeds pan/tilt and “Drag and Zoom” operation enabling finer control. 256 speeds available for system with WV-CU950 system controller.• Up to 256 preset positions• 360 map shot: 8 thumbnail images at 45 deg. intervals make it simple to direct the camera easily by clicking on a thumbnail.• Industrial grade Pan / Tilt / Zoom mechanism for high reliability• VMD (Video Motion Detection) with 4 programmable detection areas, 15 steps sensitivity level and 10 steps detection size• Privacy Zone can mask up to 32 private areas, such as house windows and entrances/exits.• Camera title display: Up to 20 alphanumeric characters on the browser• Alarm sources including 3 terminal input, VMD and Panasonic alarm command can trigger actions such as SDXC/SDHC/SD memory recording, FTP image transfer, E-mail notification, Indication on browser, Alarm terminal output, and Panasonic alarm protocol output.• Full duplex bi-directional audio allows interactive communication between camera site and monitoring site.• JPEG Image compression ratio can be changed by alarm so that higher quality image can be provided.• Prioritized stream control: One of the video streams can be prioritized when multiple recorders or client PCs are accessing the camera so that the recorder or the client PC can maintain the frame rate.• SDXC/SDHC/SD Memory card slot for manual recording (H.264 / JPEG), alarm recording (H.264 / JPEG) and backup upon network failure (H.264 / JPEG) • H.264 max. bit rate / client and Total bit rate control allows flexible network traffic management. Frame rate priority mode controls bit rate and compression ratio to provide the specified frame rate.• Internet mode: H.264 images can be transmitted over HTTP protocol.• Multi-language: English / Italian / French / German / Spanish / Portuguese / Russian / Chinese / Japanese • IPv4/IPv6 protocol supported• Supports SSL, DDNS (viewnetcam, RFC2136)• Still images (JPEG) can be viewed on mobile phones via Internet.• Onvif compliant model• IP66 rated water and dust resistant. Compatible with IEC60529 measurement standard compliant.• Dehumidification device for use in various weather conditions • Rain wash coating dome cover• Ambient Operating Temperature : -50 °C to +55 °C ( -58 °F to 131 °F )• Fog compensation function equipped as standard.• AEM (Auto Eyelid Mechanism) offers images that are more natural and easy to watch reducing doubled images when direction of the lens moved above the horizontal.HD / 1,280 x 720 H.264 Weather Proof Camera featuring 45x HD extra optical zoom and Super DynamicKey FeaturesSuper Dynamic Weather Resistant HD PTZ Dome Network CameraWV-SW397A(Rain Wash Coating Model)Trademarks and registered trademarks– Microsoft, and Windows are registered trademarks of Microsoft Corporation in the U.S. and other countries.– iPad, iPhone and iPod touch are registered trademarks of Apple Inc.– Android is a trademark of Google Inc.– UniPhier is a registered trademark of Panasonic Corporation.– "MEGA Super Dynamic", "i-PRO SmartHD" logos are trademarks or registered trademarks of Panasonic Corporation.– ONVIF and the ONVIF logo are trademarks of ONVIF Inc.Important– Safety Precaution: Carefully read the Important Information, Installation Guide and operating instructions before using this product.– Panasonic cannot be responsible for the performance of the network and/or other manufacturers' products used on the network.• Masses and dimensions are approximate. • Specifications are subject to change without notice.SpecificationsSDXC/SDHC/SDMemory Card (Option)Cellular Phone Compatibility Mobile Terminal Compatibility Alarm Source Alarm ActionsAlarm LogScheduleH.264 recording (Audio recording is enable): Manual REC / Alarm REC (Pre/Post) /Schedule REC / Backup upon network failure JPEG recording: Manual REC / Alarm REC (Pre/Post) / Backup upon network failureCompatible SD (SDHC/SDXC) card: Panasonic2 GB, 4 GB*, 8 GB*, 16 GB*, 32 GB*, 64GB** model *SDHC card, ** SDXC card (except miniSD card and microSD card) JPEG image, panning/ tilting/ zoom/ focus control, AUX control (by access level)iPad, iPhone, iPod touch (iOS 4.2.1 or later) Android mobile terminals3 terminals input, VMD, Command alarm, Audio detection SDXC/SDHC/SD memory recording, E-mail notification,Indication on browser, FTP image transfer, Panasonic protocol output With SDXC / SDHC / SD memory card: 5,000 logs, without SDXC / SDHC / SD memory card: 1,000 logsAlarm / VMD / Access permission / H.264 recording / Audio detection Monitor Output (for adjustment) Microphone/Line InputAudio OutputExternal I/O Terminals Safety/EMC StandardPower Source and Power Consumption Ambient Operating TemperatureAmbient Operating Humidity Shock ResistanceWater and Dust Resistance DimensionsMass (approx.) FinishVBS : 1.0V[p-p] / 75Ω,NTSC / PAL composite, BNC JackMIC IN and Line IN are selectable. ø3.5 mm stereo mini jack (monaural input) (Applicable microphone: Plug-in power type) Supply voltage: 2.5 V ±0.5 V Input impedance: approx. 2 kΩ ø3.5 mm stereo mini jack (monaural output) Line levelALARM IN 1 (DAY/NIGHT IN), ALARM IN 2 (ALARM OUT), ALARM IN 3 (AUX OUT) AC24 V : 3.5 A, 55 WPoE+ DC54 V: 470 mA, 25 W (IEEE802.3at compliant)POE Injector (60 W) DC54 V : 1.0 A, 50 WAC24 V and Tested PoE Injector (60 W) : –50 °C to +55 °C (-58 °F to 131 °F) * with limitations POE+ : –30°C to +55°C (–22 °F to 131 °F) Less than 90 % (no condensation)Compliant with IK10 (IEC62262)Main body : IP66 (IEC60529) compliantø229 mm x 392 mm(H) {ø9-1/32 inches x 15-7/16 inches(H)} diameter of the dome 160 mm(6-5/16 inches) Approx. 5.0 kg { 11.02 lbs}Main body : Aluminum die cast, Natural silver Sunshields : ASA resin coating, Natural silverDome section : Clear polycarbonate resin (Rain wash coating)<Safety>UL (UL60950-1), C-UL (CAN/CSA C22.2 No.60950-1), CE, IEC60950-1<EMC>FCC Part15 Class A, ICES-003 Class A, EN55022 Class B, EN55024*1 Converted value*2 For further information about PC system requirements and precautions for when using Microsoft ® Windows ® 8.1,Microsoft ® Windows ® 8, Microsoft ® Windows ® 7, Microsoft ® Windows Vista ®, or Windows Internet Explorer, click“Manual” - “Open” from the supplied CD-ROM and refer to “Notes on Windows ® / Internet Explorer ® versions”.*3 AAC (Advanced Audio Coding) is only used when recording audio on an SD memory card.*4 Transmission for 2 streams can be individually set.NetworkAlarmInput/OutputGeneralImage Sensor Effective Pixels Scanning Mode Scanning AreaMinimum IlluminationWhite BalanceLight Control ModeShutter SpeedSuper DynamicFace Super Dynamic Adaptive Black Stretch Fog compensation Gain (AGC)Electronic Sensitivity UP Day & Night (ICR)Digital Noise Reduction Video Motion Detection Privacy Zone Image Stabilizer VIQSDouble Image Reduction Camera Title (OSD) Focus distance Focal Length Zoom RatioDigital (Electrical) Zoom Angular Field of ViewMaximum Aperture Ratio Focusing Range Aperture RangePanning RangePanning SpeedTilting RangeTilting SpeedProportional Pan/Tilt Control Number of Preset Positions Auto Mode Image HoldPTZ Position Display Self Return Map Shot4.3 mm - 129.0 mm {3/16 inches - 5-3/32 inches} 30x / 45x with HD extra optical zoom (at 1280 x 720)12x (Max. 1080x combined with extra optical zoom at 640 x 360) H: 2.6° (TELE) - 64.6° (WIDE), V: 1.6° (TELE) - 38.2° (WIDE) ([16:9] mode)*H: 1.4° (TELE) - 44.4° (WIDE), V: 1.1° (TELE) - 33.8° (WIDE) ([4:3]mode)1 : 1.6 (WIDE) - 4.7 (TELE) 2.0 m - ∞ F1.6 - Close 360° endlessManual: approx. 0.065°/s to 120°/s, Up to 256 steps (depending on the controller)Preset : up to approx. 300°/s–15° to 195° (upward-level-downward)Auto Eyelid Mechanism (Double image reduction)Selectable tilting angle: 0° / –5°/ –10° / –15Manual: approx. 0.065°/s to 120°/s, Preset: up to approx. 300°/s Yes 256Auto track/ Auto pan/ Preset sequence/ 360 map-shot/ Patrol On / Off On / Off10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5 min / 10 min / 20 min / 30 min / 60 min 360° map shot / Preset map shotCamera ControlDisplay ModeCamera Title Clock Display Alarm Control One Shot Capture AudioSD Memory Data Download GUI/Setup Menu LanguageSystem Log Supported OS *2Supported BrowserImage Resolution H.264 *4JPEGImage Capture Mode:16:9H.264 : 1,280 x 720 / 640 x 360 / 320 x 180, up to 30 fps JPEG (MJPEG): 1,280 x 720 / 640 x 360 / 320 x 180, up to 30 fps 10Base-T / 100Base-TX, RJ45 connectorH.264 : 1,280 x 960 / 800 x 600 / 640 x 480 / 320 x 240, up to 30 fps JPEG (MJPEG): 1,280 x 960 / 800 x 600 / 640 x 480 / 320 x 240, up to 30 fps Network IF Audio Compression Audio ModeAuthentication for Audio Total Bit RateSupported ProtocolFTP ClientMaximum concurrent access numberPan/Tilt (256 steps), Zoom, Focus, Click centering, Drag zoom, Iris,Preset position call and program, Auto modeSpot, Quad: Image from 16 cameras can be displayed in 4 different Quad screens or 16 split screen (JPEG only). 20 characters camera title available.Up to 20 alphanumeric charactersTime: 12H/24H, Date: 5 formats on the browser, Summer time (Manual)ResetA still picture will be displayed on a newly opened window.Mic (Line) Input: On / Off Volume adjustment : Low / Middle / High Audio Output : On / Off Volume adjustment : Low / Middle / High Still or motion Images recorded in the SDXC/SDHC/SD memory card can be downloaded. English / Italian / French / German / Spanish / Portuguese / Russian / Chinese / Japanese Up to 100 (Internal)Up to 4,000 (SDXC/SDHC/SD memory when the recording format is set to JPEG.) error logs Microsoft ® Windows ® 8.1,Microsoft ® Windows ® 8, Microsoft ® Windows ® 7, Microsoft ® Windows Vista ®, Microsoft ® Windows ® XP SP3Windows ® Internet Explorer ® 11 (32 bit), Windows ® Internet Explorer ® 10 (32 bit), Windows ® Internet Explorer ® 9 (32 bit), Windows ® Internet Explorer ® 8(32 bit),Windows ® Internet Explorer ® 7 (32 bi t)Approx.1/3 type MOS image sensor Approx. 2.4 mega pixels Progressive scan5.38 mm (H ) x 3.02 mm (V ) {7/32 inches(H) x 1/8 inches(V)}Color: 0.3 lx, BW: 0.04 lx (F1.6, Auto slow shutter: Off (1/30s), Gain: On(High))Color: 0.019 lx, BW: 0.003 lx (F1.6, Auto slow shutter: Max. 16/30s, Gain: On(High)) *1AWC (2,000 - 10,000 K), ATW1 (2,700 - 6,000 K), ATW2 (2,000 - 6,000 K)Outdoor scene: Automatic integration of ALC and ELCIndoor scene [50 Hz]: Automatic integration of ALC and ELC (up to 1/100 s)Indoor scene [60 Hz]: Automatic integration of ALC and ELC (up to 1/120 s)Fix shutterFix shutter: 1/30, 3/100, 3/120, 2/100, 2/120, 1/100, 1/120, 1/250,1/500, 1/1,000, 1/2,000, 1/4,000, 1/10,000 (only at Super Dynamic Off) On / OffOn / Off (Only when Super Dynamic: On) On / Off (Only when Super Dynamic: Off) On / OffOn (Low, Mid, High) / OffOFF / AUTO (Max. 2x (2/30 s), 4x (4/30 s), 6x (6/30 s), 10x (10/30 s), 16x (16/30 s)) Mode: AUTO1 / AUTO2 / AUTO3 / On / Off, Level: High / Low, with external control High / Low4 areas, Sensitivity: 15 steps, Detection size: 10 steps Up to 8 zones / Up to 32 zones, Gray / Mosaic On / OffUp to 2 zones at preset position 1-8 and except preset On / OffUp to 20 characters (alphanumeric characters, marks) Limited / UnlimitedImage Capture Mode:4:3Transmission Mode Frame Rate Bit Rate/ClientImage Quality Refresh Interval Transmission Type Image Quality Refresh Interval Transmission TypeConstant bitrate / Frame rate priority / Best effort /Advanced VBR 1 / 3 / 5 / 7.5 / 10 / 12 / 15 / 20 / 30 fps64 / 128 / 256 / 384 / 512 / 768 / 1,024 / 1,536 / 2,048 / 3,072 / 4,096 / 6,144 / 8,192 kbps Low / Normal / Fine0.2 / 0.25 / 0.33 / 0.5 / 1 / 2 / 3 / 4 / 5 s Unicast / Multicast 10 steps0.1 fps to 30 fps Pull / PushG.726 (ADPCM) 32 kbps / 16 kbps, G.711 64 kbps, AAC *3Off / Mic (Line) input / Audio output / Interactive (Half duplex) / Interactive (Full duplex) Level 1 only / Level 2 higher / All users64 / 128 / 256 / 384 / 512 / 768 / 1,024 / 2,048 / 4,096 / 8,192 kbps / Unlimited IPv6: TCP/IP, UDP/IP, HTTP, HTTPS, RTSP, RTP, RTP/RTCP, FTP, SMTP, DNS, NTP, SNMP, DHCPv6, ICMP, ARPIPv4: TCP/IP, UDP/IP, HTTP, HTTPS, RTSP, RTP, RTP/RTCP,FTP, SMTP, DHCP, DNS, DDNS, NTP, SNMP, UPnP, IGMP, ICMP, ARP Alarm image transmission, FTP periodic transmission (When the FTP transmission is failed, backup on an optional SDXC/SDHC/SD memory card is available. ) Up to 14 users (Depends on network conditions)CameraLensPan and Tilt Browser GUINetworkDISTRIBUTED BY:/PanasonicNetworkCamera(2A-146AL)。
大华智能交通高清摄像机_使用说明书_V1.1.1
抓拍的图片可自动记录车辆的时间地点车速限速车道号图片序号违章类型等信息在单摄像机多车道抓拍的情况下在最小的抓拍间隔内若产生多个不同性质的触发抓拍信号摄像机在实现图片抓拍功能的同时能将多个触发抓拍信号在图片信息上进行标记
智能交通高清摄像机
DH-ITC523-GRB3A、DH-ITC203-GRB3A-H、 DH-ITC523-GVRB3A、DH-ITC203-GVRB3A-H、 DH-ITC213-GRB3B-H、DH-ITC213-GVRB3B-H、 DH-ITC523-CEVRB3A、DH-ITC203-CEVRB3A-H、
3 设备安装 ......................................................................................................................... - 8 -
H系列IPCamera使用手册
H系列——I P C a m e r a(网络摄像机)2009年7月版本V2.1使用手册目录1产品概述 (4)2功能介绍 (4)3设备外观与接口 (5)3.1设备外观 (5)3.2设备接口 (6)4网络连接 (7)4.1连接说明 (7)4.2访问说明 (8)5从局域网访问IP CAMERA (8)5.1设置IP地址 (8)5.2访问IP C AMERA (10)5.2.1菜单栏 (10)5.2.2视频播放区域 (10)5.2.3浏览SD卡 (11)5.2.4抓图 (11)5.2.5录像 (11)5.2.6回放 (11)5.2.7云台控制区 (12)5.3初次使用的注意事项 (12)6从互联网访问IP CAMERA (12)6.1端口映射 (12)6.2动态域名(DDNS) (13)6.2.1厂家动态域名 (13)6.2.2第三方动态域名 (14)7其它设置 (14)7.1视频设置页面 (14)7.1.1图像设置 (14)7.1.2视频设置 (15)7.2网络设置页面 (16)7.2.1基本网络设置 (16)7.2.2远程访问设置 (17)7.3告警设置页面 (18)7.3.1外部告警输入 (18)7.3.2移动侦测设置 (18)7.3.3报警模式设置 (19)7.3.4布防时间设置 (20)7.4高级设置页面 (20)7.4.1用户管理 (20)7.4.2定时抓图设置 (21)7.4.3邮件服务器设置 (22)7.4.4FTP设置 (22)7.4.5报警服务器设置 (23)7.5系统设置页面 (23)7.5.1日期与时间设置 (23)7.5.2初始化设置 (24)7.5.3设备信息查看 (24)7.5.4系统记录查看 (25)7.5.5用户访问记录查看 (25)8高级应用 (25)8.1手机访问 (25)8.2其它浏览器访问 (26)8.3集中监控软件介绍 (27)9技术参数 (27)1 产品概述IP Camera集成了网络和web服务功能,可以把摄制的视频通过网络传送到任何地方,您只需通过web浏览器就可随时访问现场视频。
QUICK GUIDE GC553 LIVE GAMER 用户指南说明书
QUICK GUIDE GC553English NederlandsDeutsch MagyarEspañol TürkçeFrançais PусскийItalianoภาษาไทยPortuguês繁體中文Polski简体中文Čeština한국어DisclaimerAll pictures contained in this documentation are example images only. The images may vary depending on the product and software version. Information presented in this documentation has been carefully checked for reliability; however, no responsibility is assumed for inaccuracies. The information contained in this documentation is subject to change without notice.Copyright and Trademark Information© 2018 by AVerMedia Technologies, Inc. All rights reserved. No part of this publication, in whole or in part, may be reproduced, transmitted, transcribed, altered or translated into any language in any form by any means without the written permission of AVerMedia Technologies, Inc. Information and specification contained in this manual are subject to change without notice and do not represent a commitment on the part of AVerMedia.For more information, please visit .AVerMedia and RECentral are trademarks or registered trademarks of AVerMedia Technologies, Inc.HeadquartersAddress No.135, Jian 1st Rd., Zhonghe Dist., New Taipei City 23585, TaiwanWebsite Support /gaming/technical_supportTelephone +886-2-2226-3630US OfficeAddress 47358 Fremont Blvd., Fremont, CA 94538, United StatesWebsite Telephone +1 (510) 403 0006Head Office EU (AVT Solutions GmbH)Address Hanauer Landstrasse 291 B, 60314 Frankfurt Hessen, GermanyWebsite /gaming/inquiry國際總部地址 23585 新北市中和區建一路 135 號網址 支援 /gaming/contact_us電話 +886-2-2226-3630中国子公司地址 上海市静安区武宁南路 488 号智慧广场 1510 室网址 电话 +86-21-52987985Important Safety Instructions1. Read these instructions.2. Keep these instructions.3. Follow all instructions.4. Heed all warnings.5. Do not use the apparatus on uneven or unstable surfaces.6. Do not use this apparatus in a wet environment or near water.7. Unplug the apparatus before cleaning. Clean only with a dry cloth.8. Use in a well ventilated environment. Do not block any ventilation openings.9. Use the apparatus within ambient temperatures 32–104°F (0–40°C).10. Use power sources within the specified voltage range.11. Do not place heavy objects on the apparatus.12. Do not install near heat sources such as radiators or stoves.13. Do not defeat the safety purposes of the polarized or grounding-type plug.14. Protect the power cord from being walked on or pinched, particularly where the cord connectswith plugs or adapters.15. Only use the attachments and accessories specified by the manufacturer.16. Unplug this apparatus during lightning or when unused for prolonged periods of time.17. Do not modify or disassemble the apparatus in any way.18. Refer all servicing to AVerMedia Customer Service.19. Do not dispose the apparatus as general household waste. Dispose in accordance with localenvironmental laws.重要安全說明1. 仔細閱讀這些說明。
AXIS P55 PTZ网络摄像头系列用户手册说明书
AXIS P55PTZ Network Camera Series AXIS P5514–EAXIS P5515-EUser ManualTable of ContentsProduct overview (3)How to access the product (4)How to access the product from a browser (4)About secure passwords (4)Setup (6)About the product's built-in help (6)Image quality (6)About overlays (7)Streaming and storage (7)About events (8)About applications (9)Troubleshooting (11)How to reset to factory default settings (11)How to check the current firmware (11)How to upgrade the firmware (11)Technical issues,clues and solutions (12)Performance considerations (13)Specifications (14)LED indicators (14)SD card slot (14)Buttons (14)Connectors (14)Product overviewProduct overviewMake sure the dome is attached in operation mode,otherwise focus may be affected.Do not point the camera lens toward the sun or other high-intensity radiation sources as this could cause damage tothe camera.1.Control button2.SD card slot3.Status indicator LED4.Restart button5.Part number(P/N)&serial number(S/N).Serial number may be required during installation.6.Screws(3)7.Sunshield8.Hook for safety wire9.Top cover screws(4)10.Unit holders(3)work connector PoE12.Sealing ring13.Top cover14.Dome cover15.Dome ring16.Dome ring screws(8)17.Grounding screwHow to access the productHow to access the productAXIS IP Utility and AXIS Camera Management are recommended methods for finding Axis products on the network and assigning them IP addresses in Windows®.Both applications are free and can be downloaded from /supportThe product can be used with the following browsers:•Chrome TM(recommended),Firefox®,Edge®,or Opera®with Windows®•Chrome TM(recommended)or Safari®with OS X®•Chrome TM or Firefox®with other operating systems.How to access the product from a browser1.Start a web browser.2.Enter the IP address or host name of the Axis product in the browser’s address field.To access the product from a Mac computer(OS X),go to Safari,click on Bonjour and select the product from thedrop-down list.If you do not know the IP address,use AXIS IP Utility to locate the product on the network.For information abouthow to discover and assign an IP address,see the document Assign an IP Address and Access the Video Stream on AxisSupport web at /supportNoteTo show Bonjour as a browser bookmark,go to Safari>Preferences.3.Enter your username and password.If this is the first time the product is accessed,the root password must first beconfigured.4.The product’s live view page opens in your browser.About secure passwordsImportantWhen setting the initial password,the password is sent in clear text over the network.If there is a risk of network sniffing,first set up a secure and encrypted HTTPS connection before resetting the passwords.The device password is the primary protection for the data and services.Axis’products do not impose a password policy as products may be used in various types of installations,but to protect your data do the following:•Don’t use the default password that comes with the products.•Use a password with at least8characters,preferably using a password generator.•Don’t expose the password.•Change password at a recurring interval,at least once a year.Set a password for the root accountImportantThe default administrator user name root cannot be deleted.If the password for root is lost,the product must be reset tothe factory default settings.How to access the productThe default root account has full privileges and should be reserved for administrative tasks.Always create a user account with limited privileges for daily use.This reduces the exposure of the administrative account.1.Make sure to follow the instructions about secure passwords,see About secure passwords on page4.2.Type a password and then retype it to confirm the spelling.3.Click Create login.The password has now been configured.SetupSetupAbout the product's built-in helpYou can access the built-in help through your product’s web page.The help provides more detailed information on the product’s features and their settings.Image qualityHow to reduce noise in low-light conditionsTo reduce noise in low-light conditions,you can adjust one or more of the following settings:NoteIncreasing the max shutter value can result in motion blur.•The shutter speed should be as slow as possible,which means you should set max shutter to the highest possible value.•Reduce sharpness in the image.•Try lowering the max gain value.How to handle scenes with strong backlightUse WDR to make both dark and bright areas of the image visible.1.Go to Settings>Image.2.Turn on WDR under Wide dynamic range.Image without WDR.SetupImage with WDR.NoteIf you use WDR,you may experience some WDR artifacts in the image.Find out more about WDR and how to use it at /web-articles/wdrAbout overlaysOverlays are superimposed over the video stream.They are used to provide extra information during recordings,such as a timestamp, or during product installation and configuration.How to show a text overlay when the camera detects motionThis example explains how to display the text“Motion detected”when the camera detects motion:1.Go to Settings>Overlay.2.Enter#D in the text field.3.Choose alignment,text size and appearance.4.Include the text overlay.5.Go to System>Events>Action rules.6.Create an action rule with AXIS Video Motion Detection as trigger.7.From the list of actions,select Overlay text.8.Type“Motion detected”.9.Set the duration.Streaming and storageHow to choose video compression formatDeciding which compression method to choose depends on your viewing requirements,and on the properties of your network.The available options are:Motion JPEGMotion JPEG or MJPEG is a digital video sequence that is made up of a series of individual JPEG images.These images are then displayed and updated at a rate sufficient to create a stream that shows constantly updated motion.For the viewer to perceive motion video the rate must be at least16image frames per second.Full motion video is perceived at30(NTSC)or25(PAL)frames per second.SetupThe Motion JPEG stream uses considerable amounts of bandwidth,but provides excellent image quality and access to every image contained in the stream.H.264or MPEG-4Part10/AVCNoteH.264is a licensed technology.The Axis product includes one H.264viewing client license.Installing additional unlicensedcopies of the client is prohibited.To purchase additional licenses,contact your Axis reseller.H.264can,without compromising image quality,reduce the size of a digital video file by more than80%compared to the MotionJPEG format and by as much as50%compared to the MPEG-4standard.This means that less network bandwidth and storage space are required for a video file.Or seen another way,higher video quality can be achieved for a given bitrate.Find out more at /compression-formatsHow to reduce bandwidth and storageImportantIf you reduce the bandwidth it can result in less details in the picture.1.Go to live view and select H.264.2.Go to the Stream tab.3.Do one or more of the following:-Turn on the Zipstream functionality and select the desired level.-Turn on the GOP and set a high GOP length value.-Increase the compression.-Turn on the dynamic FPS.How to set up network storageTo store recordings on the network,you need to set up network storage:1.Go to Settings>System>Storage.2.Click Setup under Network storage.3.Enter the IP address of the host server.4.Enter the name of the shared location on the host server.5.Move the switch if the share requires a login,and enter username and password.6.Click Connect.About eventsThe event pages allow you to configure your product to perform actions when different events occur.For example,the product can start a recording or send an email notification when motion is detected.The set of conditions that defines how and when the action is triggered is called an action rule.How to record video when the camera detects motionThis example explains how to set up the camera to start recording to the SD card five seconds before it detects motion and to stop one minute after.SetupMake sure the AXIS Video Motion Detection application is running:1.Go to Settings>Apps>AXIS Video Motion Detection.2.Start the application if it is not already running.3.Make sure you have set up the application according to your needs.Create an action rule:4.Go to Settings>System>Events and add an action rule.5.Type a name for the action rule.6.From the list of triggers,select Applications and then select AXIS Video Motion Detection(VMD).7.From the list of actions,select Record video.8.Select an existing stream profile or create a new one.9.Set the pre-trigger time to5seconds.10.Set the post-trigger time to60seconds.11.Select SD card from the list of storage options.12.Click Ok.How to automatically zoom in on a specific area with gatekeeperThis example explains how to use the gatekeeper functionality to make the camera zoom in automatically on the license plate of a car that passes through a gate.When the car has passed,the camera zooms out to the home position.Create a motion detection profile:1.Go to Settings>Apps and open AXIS Video Motion Detection.2.Create a profile that covers the entrance of the gate and then save the profile.Create the preset positions:3.Go to Settings>PTZ>Preset positions.4.Create the home position that includes the entrance of the gate.5.Create the zoomed-in preset position so that it covers the area in the image where you assume that the license platewill appear.Create an action rule:6.Go to Settings>System>Events and add an action rule. the action rule Gatekeeper.8.From the trigger list,select Applications and then select the previously created motion detection profile.9.From the action list,select the previously created preset position.10.Click OK.About applicationsAXIS Camera Application Platform(ACAP)is an open platform that enables third parties to develop analytics and other applications for Axis products.To find out more about available applications,downloads,trials and licenses,go to /applicationsSetupTo find the user manuals for Axis applications,go to Note•Several applications can run at the same time but some applications might not be compatible with each other.Certaincombinations of applications might require too much processing power or memory resources when run in parallel.Verifythat the applications work together before deployment.TroubleshootingTroubleshootingHow to reset to factory default settingsImportantReset to factory default should be used with caution.A reset to factory default resets all settings,including the IP address,to the factory default values.To reset the product to the factory default settings:1.Press and hold the control button and the restart button at the same time.2.Release the restart button but continue to hold down the control button for15–30seconds until the status LED indicatorflashes amber.3.Release the control button.The process is complete when the status LED indicator turns green.The product has been resetto the factory default settings.If no DHCP server is available on the network,the default IP address is192.168.0.90e the installation and management software tools to assign an IP address,set the password and access the video stream.How to check the current firmwareFirmware is the software that determines the functionality of network devices.One of your first actions when troubleshooting a problem should be to check the current firmware version.The latest version may contain a correction that fixes your particular problem.To check the current firmware:1.Go to the product’s webpage.2.Click on the help menu.3.Click About.How to upgrade the firmwareImportantPreconfigured and customized settings are saved when the firmware is upgraded(provided that the features are available inthe new firmware)although this is not guaranteed by Axis Communications AB.NoteWhen you upgrade the product with the latest firmware,the product receives the latest functionality available.Always readthe upgrade instructions and release notes available with each new release before upgrading the firmware.To find the latestfirmware and the release notes,go to /support/firmware1.Download the latest firmware file to your computer,available free of charge at /support/firmware2.Log in to the product as an administrator.3.Go to Settings>System>Maintenance in the product’s webpage and follow the instructions.4.The upgrade takes a while,don't break the power to the product.When the upgrade is finished,the product restartsautomatically.AXIS Camera Management can be used for multiple upgrades.Find out more at /products/axis-camera-managementTroubleshootingTechnical issues,clues and solutionsIf you can’t find what you’re looking for here,try the troubleshooting section at /supportProblems upgrading the firmwareFirmware upgrade failure If the firmware upgrade fails,the product reloads the previous firmware.The most common reasonis that the wrong firmware file has been uploaded.Check that the name of the firmware filecorresponds to your product and try again.Problems setting the IP addressThe product is located on a different subnet If the IP address intended for the product and the IP address of the computer used to access the product are located on different subnets,you cannot set the IP address.Contact your network administrator to obtain an IP address.The IP address is being used by another device Disconnect the Axis product from the network.Run the ping command(in a Command/DOS window,type ping and the IP address of the product):•If you receive:Reply from<IP address>:bytes=32;time=10...this means that the IP address may already be in use by another device on the network.Obtain a new IP address from the network administrator and reinstall the product.•If you receive:Request timed out,this means that the IP address is available for use with the Axis product.Check all cabling and reinstall the product.Possible IP address conflict with another device on the same subnet The static IP address in the Axis product is used before the DHCP server sets a dynamic address. This means that if the same default static IP address is also used by another device,there may be problems accessing the product.The product cannot be accessed from a browserCannot log in When HTTPS is enabled,ensure that the correct protocol(HTTP or HTTPS)is used when attempting to log in.You may need to manually type http or https in the browser’s address field.If the password for the user root is lost,the product must be reset to the factory default settings.See How to reset to factory default settings.The IP address has been changed by DHCP IP addresses obtained from a DHCP server are dynamic and may change.If the IP address has been changed,use AXIS IP Utility or AXIS Camera Management to locate the product on the network.Identify the product using its model or serial number,or by the DNS name(if the name has been configured).If required,a static IP address can be assigned manually.For instructions,go to /support.Certificate error when using IEEE802.1X For authentication to work properly,the date and time settings in the Axis product must be synchronized with an NTP server.Go to Settings>System>Date and timeThe product is accessible locally but not externallyRouter configuration Check that your router allows incoming data traffic to the Axis product.The router must support UPnP®.Firewall protection Check the Internet firewall with your network administrator.Problems with streamingMulticast H.264only accessible by local clients Check if your router supports multicasting,or if the router settings between the client and the product need to be configured.The TTL(Time To Live)value may need to be increased.No multicast H.264 displayed in the client Check with your network administrator that the multicast addresses used by the Axis product are valid for your network.Check with your network administrator to see if there is a firewall preventing viewing.TroubleshootingPoor rendering of H.264 images Ensure that your graphics card is using the latest driver.The latest drivers can usually be downloaded from the manufacturer’s website.Color saturation is different in H.264and Motion JPEG Modify the settings for your graphics adapter.Go to the adapter’s documentation for more information.Lower frame rate than expected •See Performance considerations on page13.•Reduce the number of applications running on the client computer.•Limit the number of simultaneous viewers.•Check with the network administrator that there is enough bandwidth available.•Lower the image resolution.•In the product’s webpage,set a capture mode that prioritizes frame rate.Changing the capture mode to prioritize frame rate might lower the maximum resolution depending on the product used and capture modes available.Performance considerationsWhen setting up your system,it is important to consider how various settings and situations affect the performance.Some factors affect the amount of bandwidth(the bitrate)required,others can affect the frame rate,and some affect both.If the load on the CPU reaches its maximum,this also affects the frame rate.The following factors are the most important to consider:•High image resolution or lower compression levels result in images containing more data which in turn affects the bandwidth.•Access by large numbers of Motion JPEG or unicast H.264clients affects the bandwidth.•Simultaneous viewing of different streams(resolution,compression)by different clients affects both frame rate and bandwidth.Use identical streams wherever possible to maintain a high frame rate.Stream profiles can be used to ensure thatstreams are identical.•Accessing Motion JPEG and H.264video streams simultaneously affects both frame rate and bandwidth.•Heavy usage of event settings affects the product’s CPU load which in turn affects the frame rate.•Using HTTPS may reduce frame rate,in particular if streaming Motion JPEG.•Heavy network utilization due to poor infrastructure affects the bandwidth.•Viewing on poorly performing client computers lowers perceived performance and affects frame rate.•Running multiple AXIS Camera Application Platform(ACAP)applications simultaneously may affect the frame rate and the general performance.SpecificationsSpecificationsTo find the latest version of the product’s datasheet,go to >[product]>Support&Documentation.LED indicatorsStatus LED IndicationUnlit Connection and normal operation.Green Shows steady green for10seconds for normal operation after startup completed.Amber Steady during startup.Flashes during firmware upgrade or reset to factory default.Amber/Red Flashes amber/red if network connection is unavailable or lost.SD card slot•Risk of damage to SD card.Do not use sharp tools,metal objects,or excessive force when inserting or removing theSD e your fingers to insert and remove the card.•Risk of data loss and corrupted recordings.Do not remove the SD card while the product is running.Unmount the SD cardfrom the product’s webpage before removal.This product supports SD/SDHC/SDXC cards(not included).For SD card recommendations,see ButtonsControl buttonThe control button is used for:•Resetting the product to factory default settings.See How to reset to factory default settings on page11.•Connecting to an AXIS Video Hosting System service.To connect,press and hold the button for about3seconds until the status LED flashes green.Restart buttonPress the restart button to restart the product.ConnectorsNetwork connectorRJ45Ethernet connector with Power over Ethernet(PoE).User Manual Ver.M1.9 AXIS P55PTZ Network Camera Series Date:July2017©Axis Communications AB,2017Part No.1754145。
AXIS V5925 PTZ 摄像头:广播质量的HDTV 1080p PTZ 摄像头说明书
AXIS V5925PTZ CameraBroadcast-quality HDTV 1080p PTZ cameraAXIS V5925combines excellent image quality with smooth PTZ control and broadcast-quality audio for professional webcasting.It’s compatible with VISCA joysticks and VISCA over IP,making it easy to integrate with your existing AV installations.Offering enhanced security features such as signed firmware and secure boot,it ensures the integrity and authenticity of the firmware.Furthermore,Axis Zipstream with H.264and H.265significantly reduces bandwidth and storage requirements without compromising image quality.>HDTV 1080p at 60fps and 30x zoom >High-quality audio with XLR inputs >VISCA and VISCA over IP support >Camstreamer 3-month trial included >3G-SDI and HDMIoutputsDatasheetAXIS V5925PTZ Camera CameraImage sensor Progressive scan RGB CMOS1/2.8"Lens 4.4–132mm,F1.4-4.6Horizontal field of view:62°–2.3°Vertical field of view:37°–1.3°Autofocus,P-iris controlDay and night Automatically removable infrared-cut filterMinimum illumination Color:1.0lux at30IRE F1.4 B/W:0.03lux at30IRE F1.4Shutter speed1/10000s to1sPan/Tilt/Zoom Pan:±170°,0.2-100°/sTilt:-20°-90°,0.2-90°/sZoom:30x Optical,12x Digital,Total360x256presets positions,Control queue,On-screen directionalindicator,Adjustable zoom speed,PTZ response profiles System on chip(SoC)Model ARTPEC-7Memory1GB RAM,512MB FlashVideoVideo compression H.264(MPEG-4Part10/AVC)Baseline,Main and High Profiles H.265(MPEG-H Part2/HEVC)Main ProfileMotion JPEGResolution1920x1080HDTV1080p to160x90HDMI/SDI Output:1080p@50/60fps(50/60Hz)Frame rate Up to60/50fps(60/50Hz)in all resolutionsVideo streaming Multiple,individually configurable streams in H.264,H.265and Motion JPEGAxis Zipstream technology in H.264and H.265Controllable frame rate and bandwidthVBR/ABR/MBR H.264/H.265HDMIHD-SDI:SMPTE2923G-SDI:SMPTE424,SMPTE425(3G-SDI mapping supportsLevel A/Level B dual link mapping)Image settings Saturation,brightness,sharpness,white balance,day/nightthreshold,exposure mode,exposure zones,defogging,rotation:0°,180°AudioAudio streaming Two-way,stereoHD-SDI:SMPTE ST299-13G-SDI:SMPTE ST299-2Audio encoding SDI:AES324bit,48kHzHDMI:LPCMNetwork:AAC LC8/16/32/44.1/48kHz,G.711PCM8kHz,G.726ADPCM8kHz,Opus8/16/48kHz,LPCM48kHz,Configurable bit rateXLR input2balanced inputs(left/right)Microphone phantom power48VBalanced external microphoneBalanced line levelLine input impedance:>10kOhmMaximum input level:4.4VrmsBandwidth:20Hz-20kHz(±3dB),may be limited by samplerateTHD+N:<0.03%Signal-to-Noise ratio:>85dB@0dB gain,>78dB@30dB gain3.5mm input Microphone Power5V via2.2kOhmUnbalanced external microphoneUnbalanced lineLine input impedance:>10kOhmMaximum input level:2.2VrmsBandwidth:20Hz-20kHz(±3dB),may be limited by samplerateTHD+N:<0.03%Signal-to-Noise ratio:>87dB@0dB gain,>83dB@30dB gain3.5mm output 3.5mm unbalanced stereo outputOutput impedance:<100Ohm,short circuit proofMaximum output level:>0.707VrmsBandwidth:20Hz-20kHz(±3dB),may be limited by samplerateTHD+N:<0.03%@10kOhm loadSignal-to-Noise ratio:>87dBSDI output Bandwidth:20Hz-20kHz(±3dB)THD+N:<0.03%Signal-to-Noise ratio:>87dBHDMI output Bandwidth:20Hz-20kHz(±3dB)THD+N:<0.03%Signal-to-Noise ratio:>87dBNetworkSecurity Password protection,IP address filtering,HTTPS a encryption,IEEE802.1x(EAP-TLS)a network access control,digestauthentication,user access log,centralized certificatemanagement,brute force delay protection,signed firmware,secure bootSupportedprotocolsIPv4/v6,ICMPv4/ICMPv6,HTTP,HTTP/2,HTTPS a,TLS a,QoS Layer3DiffServ,FTP,CIFS/SMB,SMTP,mDNS(Bonjour),UPnP TM,SNMPv1/v2c/v3(MIB-II),DNS/DNSv6,DDNS,NTP,RTSP,RTP,SFTP,TCP,UDP,IGMPv1/v2/v3,RTCP,ICMP,DHCPv4/v6,ARP,SOCKS,SSH,SIP,LLDP,CDP,MQTT,Syslog,Link-Local address(ZeroConf),HDMI,3G-SDI,VISCASystem integrationApplicationProgrammingInterfaceOpen API for software integration,including VAPIX®andAXIS Camera Application Platform;specifications at One-click cloud connectionONVIF®Profile G,ONVIF®Profile M,ONVIF®Profile S,specification at Support for Session Initiation Protocol(SIP)for integration withVoice over IP(VoIP)systems,peer to peer or integrated withSIP/PBX.Event conditions Analytics,external input,edge storage events,virtual inputsthrough APIAudio:audio detectionCall:state,state changeDevice status:above operating temperature,above or belowoperating temperature,below operating temperature,fan failure,IP address removed,network lost,new IP address,storage failure,system ready,within operating temperatureEdge storage:recording ongoing,storage disruptionI/O:digital input,manual trigger,virtual inputMQTT subscribePTZ:PTZ malfunctioning,PTZ movement,PTZ preset positionreached,PTZ readyScheduled and recurring:scheduled eventVideo:average bitrate degradation,live stream openEvent actions MQTT publishRecord video:SD card and network shareUpload of images or video clips:FTP,SFTP,HTTP,HTTPS,networkshare and emailPre-and post-alarm video or image buffering for recording oruploadNotification:email,HTTP,HTTPS,TCP and SNMP trapPTZ:PTZ presetOverlay text,external output activation,play audio clip,zoompreset,day/night mode,make callData streaming Event dataBuilt-ininstallation aidsPixel counter,leveling guideAnalyticsApplications IncludedAXIS Video Motion Detection,AXIS PTZ AutotrackingSupport for AXIS Camera Application Platform enablinginstallation of third-party applications,see /acap GeneralCasing ASA plastic coverColor:White NCS S1002-BPower11–13V DC(12V power supply included),typical14W,max25W Connectors RJ4510BASE-T/100BASE-TXTerminal block for2configurable alarm input/output3.5mm stereo mic/line in,3.5mm stereo line outXLR-3(left+right)mic/line in(with48V phantom power)HDMI Type A,BNC for SDIDC inputRS232serial connector for VISCAStorage Support for microSD/microSDHC/microSDXC cardSupport for SD card encryption(AES-XTS-Plain64256bit)Recording to network-attached storage(NAS)For SD card and NAS recommendations see Operating conditions 0°C to40°C(32°F to104°F) Humidity10-85%RH(non-condensing)Storage conditions -40°C to65°C(-40°F to149°F) Humidity5-95%RH(non-condensing)Approvals EMCEN55032Class A,EN55035,EN61000-3-2,EN61000-3-3,EN61000-6-1,EN61000-6-2,FCC Part15Subpart B Class A,ICES-3(A)/NMB-3(A),VCCI Class A,RCM AS/NZS CISPR32Class A,KC KN32Class A,KC KN35SafetyIEC/EN/UL62368-1,CAN/CSA C22.2No.62368-1,KC-Mark,IS13252EnvironmentIEC60068-2-1,IEC60068-2-2,IEC60068-2-6,IEC60068-2-14,IEC60068-2-27,IEC60068-2-78NetworkNIST SP500-267Dimensions Height:180mm(7.1in)ø136mm(5.4in)Weight 1.5kg(3.3lb)IncludedaccessoriesPower supply,wall/ceiling mount,terminal connector for I/O,installation guide,Windows®decoder user license,Camstreamer3-month trialOptionalaccessoriesAXIS T8310Video Surveillance Control BoardAXIS VISCA CableFor more accessories,see Languages English,German,French,Spanish,Italian,Russian,SimplifiedChinese,Japanese,Korean,Portuguese,Traditional Chinese Warranty5-year warranty,see /warrantya.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.(),and cryptographic software written by Eric Young (*****************).Environmental responsibility:/environmental-responsibility©2020-2021Axis Communications AB.AXIS COMMUNICATIONS,AXIS,ARTPEC and VAPIX are registered trademarks ofAxis AB in various jurisdictions.All other trademarks are the property of their respective owners.We reserve the right tointroduce modifications without notice.T10155563/EN/M10.4/2111。
使用说明书——精选推荐
R使用說明書Operating Instructions數位攝錄影機Digital Video CameraModel No. NV-GS150GC使用前,請仔細閱讀本說明書。
Before use, please read these instructions completely.VQT0N45-1安全注意事項ª請仔細閱讀使用說明書並正確使用攝像機。
≥由於未按照使用說明書中說明的操作步驟進行操作,而導致的損害或材料的損壞僅由用戶負責。
試用攝像機在記錄首個重要事件前,首先要試用一下攝像機,以保證其錄製性能與各種功能能夠正常使用。
製造商對於錄製內容的損失不承擔任何責任。
製造商對於因攝像機、其附件或錄影帶的故障或缺陷造成的任何損失概不負責。
請嚴格遵守版權法。
若非個人使用,複製先期錄製的錄影帶、磁碟、其他出版物或播放材料都侵犯版權法。
即使是個人使用,也嚴禁複製某些特定的材料。
≥攝像機使用了版權保護技術,並且被日本和美國的專利技術和知識產權所保護。
要想使用這些版權保護技術,必須得到Macrovision公司的授權。
禁止分解或改裝攝像機。
≥Windows是美國Microsoft公司的商標或註冊商標。
≥SD徽標是商標。
≥Leica是Leica microsystems IR GmbH公司的註冊商標,Dicomar是Leica Camera AG公司的註冊商標。
≥使用說明書中的所有其他公司和產品名稱都是各個公司的商標或註冊商標。
錄製在SD記憶卡上的檔案本攝像機可能無法回放由其他設備錄製和創建的檔案,反之亦然。
為此,請預先檢查設備的相容性。
≥讓記憶卡遠離兒童的接觸範圍,以防止兒童吞服。
參照頁參照頁頁碼的兩側標有短划線,例如:-00-菜單操作流程用>>表示。
ª警告若要防止電擊,請勿卸下機身的前蓋(或後蓋);機身沒有用戶可維修的部件。
需要維修時,請聯係授權的維修人員。
請僅使用推薦的附件。
摄像机GC-HX553中文说明书
Warning: This equipment generates and uses radio frequency energy and if not installed and used properly, I.e., in strict accordance with the instruction manual, may cause harmful interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Warning: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
a. If the power-supply cord or plug is damaged. b. If the camera has been exposed to rain or water. c. If liquid has been spilled, or objects have fallen into the camera. d. If the camera does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the camera to its normal operation. e. If the camera has been dropped or the cabinet has been damaged. f . If the camera exhibits a distinct change in performance.
5545产品说明书
90TDY-300 AC220V 灯箱风机: 离心风机 100FLJ-14 离心风机 100FLJ-14 轴流风机 SF11025A 离心风机 85FLJ-16
P/N2112HSL
2、放映频率:在额定电压范围内为
根据用户需要可提供 2000m 片夹,并可快速在本机倒片。 15、收片特性:最大拉力与最小拉力之比 N≤2.5。 16、光轴高度:1.25m。 17、光轴最大仰角 5°,俯角 10°。 18、放映机消耗功率
1000W 氙灯 2KVA 2000W 氙灯 3KVA
19、放映机总重量
2000W 氙灯 3000W 氙灯
3.5KVA 5KVA
3000W 氙灯 5KVA(5545N5) 4000W 氙灯 6KVA(5545N5) 5000W 氙灯 7.5KVA(5545N5) 7000W 氙灯 9KVA(5545N7)
220kg
20、放映机最大外型尺寸:长×宽×高 600 米片盘
906×468×1926
2000 米片夹 1100×468×2219
(四)放映光学系统如图 3.4 光源 1 采用高压短弧氙灯,具有较高的发光效率和理想的光谱特性。深椭圆冷反光镜 2 把氙 灯发出的光线,集中地反射到反光镜第二焦点(片门处)。圆锥遮光器 3 以每秒 48 次遮挡光线, 片门 4 中的影片每一画幅在静止状态曝光两次,以每秒 24 个画幅的放映频率和 48 次的闪烁曝光, 通过放映镜头 5 和变形镜头 6 投射到银幕上。
“松花江”5545 系列电影放映机
产品说明书
哈尔滨哈影电影机械有限公司
目录
一、 概述…………………………………………………………1 二、 主要技术参数………………………………………………2 三、 放映机的光、机系统………………………………………4 四、 放映机的主要部分结构……………………………………8 五、 电气控制系统 ……………………………………………23 六、 放映机的包装运输和储存 ………………………………33 七、 放映机的安装和调整 ……………………………………33 八、 放映机的使用与维护 ……………………………………47 九、 放映机检测及一般故障的排除 …………………………56 十、 易损零件明细表 …………………………………………61