日本nireco AE1000纠偏控制器说明

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Liteguide Controller

Model AE1000Operator's Manual

QJ2802.0-E 2009.2

1.About this Manual (1)

1.1

Safety Considerations............................................................................... 21.2Exemption Items.. (2)

s and Functions of Component Parts (3)

2.1Front Panel Component Labels (3)

2.2Front Panel Components (4)

3.Operation (9)

3.1Basic Flow of Operations (9)

3.2When Adjusting the Gain (10)

3.3The Shift Function (11)

3.4Autobalance (12)

3.5Polarity Inversion Key (LH8B) (15)

4.Appendix (17)

4.1I/O Display Details (17)

4.2Switch Panel (19)

4.3Main Board (20)

4.4T erminal Block (22)

Annotations and other important additional information are marked using Note:thoroughout this manual

Contents

About this Ma nual

This is an op erating manual for safely and correctly imp lementing any of the controls

below using a system consisting of the field-tested AE1000, various sensors and an electric

actuator (plus other related equipment).

This section is limited to explaining the operating mode.

For an exp lanation of the settings mode (i.e., the mode for modifying p arameters or

carrying out confirmation) and other details, p lease refer to the AE1000 Instruction

Manual (QJ2801.*-E).

Control Types (excluding options)

EPC (Edge Position Control)

EPC is used to prevent the across-the-width position from moving out of alignment by

monitoring one edge of a web* (the edge position) by sensor.

CPC (Center Position Control)

CPC is used to ensure that a web passes through a machine center by monitoring both

edges of the web with two sensors and always ensuring that the output of the two sensors

is the same.

LFC (Line Follower Control)

LFC is used to prevent the across-the-width position from moving out of alignment by

monitoring a web control target (i.e., a printing line, printing edge, etc.).

Note:"Web" refers to any sheet-shaped product, including paper, film and metal sheeting that passes through a printing or processing line.

Na mes a nd Functions of Component Pa rts Array

Up/Down key ( , key)

These keys increase and decrease the value when in the gain adjustment or shift

adjustment screens.

Otherwise, the keys are used to switch screens (P1 to P6) while in operating mode.

Polarity inversion key (NOR/REV key)

This key reverses the polarity of a sensor signal.

The function ap p lies to SNS1 POL or SNS2 POL for the p arameters (internal

settings).

Note:By default, inversion is effective only when the LH8B sensor is selected.

See 3.5 Polarity Inversion Key for details of the polarity inversion key.

Note:"Default" refers to the factory settings.