Lynx EVO 体视显微镜产品说明书
Lynx 立体显微镜-无眼睛镜头-1981年版说明书

®Lynx Stereo Microscope without eyepieces hasmultiple accessory options for a wide variety of tasks including:• Inspection • Manipulation • Assembly • Dissection • Soldering • Polishing • Finishing• Measurement and recordingLynx utilises Vision Engineering’s patented Dynascope ®technology. Dynascopetechnology expands the exit pupil of optical microscope layouts by utilising multi-lens image forming surfaces. The benefits to the operator are:• Superb resolution and contrast • Increased head and body freedom• Freedom to wear glasses and contact lenses • Easy hand to eye co-ordination resulting in greater speed, throughput, accuracy and reduced scrap ratesStereo Microscope®Lens Zoom Working Field of Field of MagnificationRange Distance View at View at Max Zoom Min Zoom X0.3X2.1 – X12312mm 12mm 77mm X0.5X3.5 – X20175mm 7mm 46mm X0.7X4.9 – X28127mm 5mm 33mm X1.0X7.0 – X4085mm 3.5mm 24mm X1.5X10.5 – X6045mm 2.5mm 16mm X2.0X14 – X8025mm1.75mm12mmDynascope afocal stereo zoom eyepieceless microscope field angleDynascope patented technology optimises head and body - 10mm Radial head freedom - 70mm Axial head freedomZoom Magnification:7-40X multiplied by combinations of objective lenses and multipliers (Zoom Magnification Maximum 160X)Zoom Ratio 5.7:1Secondary Multipliers 1.5X, 2.0XReducing objectives to increase working distance and field of view (see table below)Magnifying objectives to increase overall magnification.Electrostatic Discharge Option:For sensitive electrostatic applications, Lynx is available with high performance discharging plastic with full grounding, meet-ing the highest ESD specifications. (please ask for details)Unpacked Head 3.4kg Stand 5.5kg Packed Head 4.7kg Stand 6.5kg Illumination Options:6 or 10 point ringlight options with 21V/150W Halogen lamp house (200 hours approx. life) or 24V/250W Halogen lamp house (300 hours approx. life)Substage illumination (bench stand only) 12V/20W Halogen lamp (2000 hours approx. life)Option of tilting substage illuminator to enhance contrast (see separate Accessories Brochure for more details)Magnification Multipliers:Oblique and Direct viewer gives angled view of subject 35°rotating angle from vertical, motorised or manual options Tilting, spring mounted head angle adjuster for different Fixed Head Angle Adjuster (from horizontal)Polarised light substage illuminator Measuring workstageVertical or crossline measuring reticleCamera adaptors for digital cameras, CCTV , 35mm,Polaroid, image analysis or archiving softwareTechnical SpecificationOptical Information:ADimensions: A = 400mmMaximumAround the worldVision Engineering Ltd (Manufacturing)Send Road, Send, Woking,Surrey, GU23 7ER EnglandTel:+44 (0) 1483 223417Fax:+44 (0) 1483 223297Vision Engineering Ltd (Commercial)Monument House Monument Way WestWoking, Surrey, GU21 5EN EnglandTel:+44 (0) 1483 248300Fax:+44 (0) 1483 248317E-Mail:*************************Website: Vision Engineering Inc.(Manufacturing & Commercial)570 Danbury Road,New Milford,CT 06776USATel:+1 (860) 355 3776Fax:+1 (860) 355 0712E-Mail:******************Website: Vision Engineering Inc.(Commercial)745 West Taft Avenue,Orange,CA 92865,USATel:+1 (714) 974 6966Fax:+1 (714) 974 7266Vision Engineering Ltd (Central Europe)Anton Pendele Strasse 3,D-82275, Emmering,GermanyTel:+49 (0) 8141 40167-0Fax:+49 (0) 8141 40167-55E-Mail:*****************Website:www.visioneng.deNippon Vision EngineeringNo. 6 Shinyokohama Hayama Building 1-28-8 ShinyokohamaKohoku-ku, Yokohama-shi,JapanTel:+81 (0) 45 472 1004Fax:+81 (0) 45 472 1177E-Mail:*****************Website:www.visioneng.jp Vision Engineering Ltd 1 Rue de Terre Neuve ZA Courtaboeuf91967 Les Ulis Cedex FranceTel:+33 (0) 164 46 90 82Fax:+33 (0) 164 46 31 54E-Mail:*****************Website:www.visioneng.fr Vision Engineering Ltd Italia Via Pelizza da Volpedo 5120092 Cinisello Balsamo MI ItalyTel:+39 02 6129 3518Fax:+39 02 6129 3526E-Mail:*****************Website:www.visioneng.itWe serve industry and laboratories world wide, from major multinational corporations to small privately owned companies.Each receives the same high standard of pre and post sales service, whether direct from one of Vision’s subsidiaries or one of our highly trained and skilled distributors. With our products now represented in over 30countries, Vision responds to customer demand with speed, efficiency and withinnovative solutions.Visit our Interactive Multilingual Website。
ZEISS KINEVO 900 高精度手术显微镜说明书

Advancing Surgical CertaintyKINEVO 900 – The Robotic Visualization System Just like you, we love challenging the status quo.The result? Over 100 innovations to perfect the already acclaimed surgical visualization platform. KINEVO® 900 from ZEISS is designedto deliver more functionalities than any surgical microscope today.ZEISS KINEVO 900 combines digital and optical visualization modalities, offers a unique Micro-Inspection Tool and will impress you with its Surgeon-Controlled Robotics. All to enable you to gain greater certainty in a virtually disruption-free workflow.Designed to meet real needs. To make a real difference!A lot more. And, a lot less too.When treating complex vascular conditions, you typically work at high magnification. Even the slightest vibrations can cause disruptions. And constant manual repositioning to better visualize structures or precisely approach deep-seated lesions can become extremely tedious. Not anymore! ZEISS KINEVO 900 delivers a lot more positioning precision with a lot less effort.PointLockSurgeon-Controlled Robotics adds a complete new level of ease to precise positioning. Imagine being able to focus and move around a structure to visualize the targeted anatomy – reducing any manual hassle. In addition, PointLock enables you to do a KeyHole movement to observe a larger area inside a cavity – a particular benefit in areas with narrow access. Simply put:Focus. Activate. Swivel.Active vibration dampingYou know the problems that can be created by the tiniest vibrations. The active damping provided by ZEISS KINEVO 900 minimizes collateral system vibrations, ensuring rock-solid stability. Enabling you to completely, and steadily, focus on what matters most:your treatment.Focus Activate Swivel5When you need it. Where you need it.The new navigation interface of ZEISS KINEVO 900 is designed to work in concert with your navigation device. When you require precise repositioning to reexamine previously visualized structures or when you need to align with a pre-mapped trajectory, making use of all six axes, the Robotic Visualization System ® delivers precise positioning at the push of a button. Putting you exactly where you need to be – when you need to be there.PositionMemoryWhen working on a tumor case, you may already have identified regions of concern where you want to protect the functional structure. After storing these in PositionMemory , you can come back and visualize them at the exact same magnification, working distance and focus – without losing time for manual repositioning. In a nutshell: Save. Move. Recall.Image-guided surgeryMinimize time-consuming efforts in approaching challenging neurosurgicalpathologies. Combine the Surgeon-Controlled Robotics of ZEISS KINEVO 900 with navigation interface to approach deep-seated pathologies in cranial surgery, brain stem or skull base tumor removals –right when you need it.Save Move RecallImage with Brainlab Microscope Navigation Software7New dimensions. Freedom of choice. Working through oculars at extreme angles can sometimes be a pain in the neck. Literally. With no way out, you might have to contend with uncomfortable working positions causing fatigue. Now, relief and revolutionary dimensions in visualization arein sight.The Digital Hybrid Visualization with integrated 4K technology of ZEISS KINEVO 900 welcomes you to a world of heads-up ocular-free surgery, giving you freedom of movement. And freedom of choice to use an optical setup, depending on the application need.Fully integrated 4K camera technologyDuring lateral lumbar or thoracic spine and posterior fossa approaches,ZEISS KINEVO 900’s integrated 4K visualization can be essential. It providesyou with multimodal visualization capabilities – the flexibility to decouple fromthe classic optical approach and to work with outstanding 4K picture qualityand clarity. Even when magnifying tiny details.What’s more… your assistant surgeon, OR staff and residents also benefit from the 4K visual clarity of ZEISS KINEVO 900. They share the same high-resolution, digital image to follow the procedure with comparable fidelity. Delivering indispensable education and training.9Critical challenge. Vital solution.Your challenge: When working from an external perspectiveof a surgical microscope, your visualization of the anatomy is limited to a straight line of sight – missing critical information behind tissue or corners. Efficient and effortless access to this comprehensive information is essential for treatment.Our solution: QEVO® from ZEISSThe unique, proprietary Micro-Inspection Tool from ZEISS complements intraoperative microsurgical visualization, enabling you to discover unexplored areas during the surgical intervention without additional footprint. You can look around corners and eliminate blind spots. And most importantly, you can gain greater insights – for better clinical decisions.To support your surgical workflow, ZEISS QEVO is engineered with an angled design – keeping your hands out of the lineof sight during insertion in the surgical field. And, it allowsfor an easy fit between the ZEISS KINEVO 900 and the situs, eliminating the need to reposition the head of the device. Greater insights, on demand.ZEISS QEVO enables you to inspect the perforator or examine the distal neck of the aneurysm to ensure the clip blades are fully extended.11Ease of use. Peace of mind.Surgical certainty is your imperative. Enabling you to achieve it is ours. That’s why, in the development of the Micro-Inspection Tool, we placed a high priority on its ease of use.ZEISS QEVO is truly integrated. You don’t have to plan foran additional device during surgery. Just plug it into your ZEISS KINEVO 900 for a seamless surgical workflow and to easily switch back and forth between views.ZEISS QEVO is fully autoclavable.So there’s no need forany additional draping. This is another attribute that makes ZEISS QEVO an indispensable tool – always available during surgery. On demand.ZEISS QEVO. Innovation in action.ZEISS KINEVO 900 can support discerning regions that are not directly visualized – avoiding unnecessary bone removal and retraction. During a Vestibular Schwannoma case, for instance, it can help identify the course of facial nerves. And, can support inspection of regions that are not directly visualized by a surgical microscope.1314For the fluorescence distribution: The IntensityMap enables you to conveniently identify relativefluorescence levels reached during the INFRARED800 observation period.For the speed of the flow: The Speed Mapindicates how fast the fluorescence intensityincreased during the observation period –indicating the speed of the blood flow.For the indicative time: The Delay Map (orSummary Map) provides quick information aboutthe time when the fluorescent signal appeared foreach image point in the map.1PZEISS BLUE 4001ZEISS YELLOW 5601Visualization of fluorescence-stained structures using BLUE 400 during surgery.Visualization of fluorescence-stained structures using YELLOW 560.For a complete picture: The Diagram Functionoutlines assessment of fluorescence intensityvariation over time and fast access to the keyindicators for further analysis.BeforeFor no compromises:After15Setting new benchmarks. Shaping a new future. When we envisioned the all-new Robotic Visualization System,we conceived a design that can deliver so much more withoutlosing its familiarity. With ZEISS KINEVO 900, we continue tolive our vision of supporting you in becoming one with yourvisualization system – of delivering purposeful innovations.ones that matter the most for you.The Robotic Visualization System: The first of its kind.Surgeon-Controlled RoboticsDelivering precise positioning with a lotless effort – with motors in all axes.ZEISS QEVO – The Micro-Inspection ToolComplementing intraoperative microsurgicalvisualization to discover unexplored areasduring surgical intervention. Gain greaterinsight. On demand.16Digital Hybrid VisualizationProviding an opportunity for ocular-free surgery, with the freedom to use a traditional optical setup – depending on the application need.Integrated Intraoperative Fluorescence –The Power of Four.The redesigned intraoperative fluorescence technologies from ZEISS offer you the Power of Four – so you always have the tools you need.17Digital connectivity. Transforming OR’s.ZEISS ConnectZEISS Observe Neurosurgery, in particular, is a technologically intensivesurgical discipline. This has pushed us toward the edge oftransformation: to develop leading digital technologiesenabling you to expand the boundaries of surgical care –to the next level.ZEISS KINEVO 900 offers full digital connectivity.Manage surgical data wherever you are: ZEISS Connect App1enables you to access your surgical data from your iOS device,and also delivers dedicated functionalities for efficient work-flows.Take teaching to new heights: ZEISS Observe App enablesyou to virtually broadcast your procedure in the OR. Yourstudents can follow the live surgery directly on mobile screensor immerse themselves in a rich VR Experience.Gain value with new digital services: ZEISS Smart Servicesenables faster support for you and your team with remoteconnectivity. Benefit from the increased system availabilitypowered by a secure connection to your ZEISS KINEVO 900.1 Available soon18Connecting simplicity and innovation.ZEISS SMARTDRAPEYour visualization needs are paramount to us. And, soare the needs of your team. That’s why we gave a specialfocus to the OR preparation process in the developmentof ZEISS KINEVO 900.Being an integral part of the optical path, the SMARTDRAPEwith VisionGuard® from ZEISS is designed together withZEISS KINEVO 900 so you and your team can have thebenefits of a vivid view, and effective patient protection.At the same time – the new innovations make the drapingprocess simply simple!• Innovative folding: to eliminate guesswork and complexity.• Intuitive attachment: for an effortless and simple self-locking mechanism.• Integrated RFID chip: for easy activation of AutoDrape®.Designed for ZEISS KINEVO 900.Support whenever you need it.ZEISS OPTIMEIf you rely on high system availability, consider our ZEISSOPTIME service agreements, which are designed to ensurethe readiness of our medical equipment when you need it.ZEISS OPTIME service agreements for ZEISS KINEVO 900now come with connectivity for ZEISS Smart Services.19Technical DataKINEVO ® 900 from ZEISS5°A x i s 6-25° / +135°A x i s 4±45°A x i s 5-28° / +20°A x i s 3n x 360°A x i s 1M o n i t o r R o t a t i o n : ±125°T i l t i n g : -20° / +5° (±3°)c a . 530 - 1635 m m820 m mm a x . c a .1760m m Technical DataRated Voltage 100 V – 240 VCurrent Consumption Max. 1.350 VARated Frequency 50 Hz – 60 HzElectrical Standard Complying with IEC 60601 1:2005+A1:2012Protection class I, degree of protection IP20Class 2 laser product as perapprox. 525 kg20QEVO® from ZEISS and QEVO ECUTechnical DataDirection of View45° upwardsShaft Diameter 3.6 mmShaft Length120.0 ± 1.0 mmTotal Diameter13.0 mmField of View 100° ± 5° wide angle viewIllumination20 – 35 lumen LEDWeight (without cable)250 gSterilization AutoclavableImage Resolution1920 x 1080 pixel full HDLength of Cable5000 mmOperation Temperature+10 to +40 °C (500/1000 s intermittent use)QEVO ECUDimensions Length = 265.0 ± 1 mm, height = 59.3 ±1 mm and depth = 212.2 ± 1 mmWeight 2.5 kgOperating Voltage24V (+/- 10%) ADCVideo Output DVI-D full HDCable length: 5 m21Technical DataVideoStereo video camera 3D HD, fully integrated, 2 x 3-chip HD, 1080p incl. 2nd HD 3D monitor 4K video camera, fully integrated 3-chip 4K, 2160p Stereo video camera 4K 3D, fully integrated, 2 x 3-chip 4K, 2160p, incl. 2nd HD 3D monitor Integrated HD video recording, withSmartRecording, low-Resolution recording, editing and streaming 2nd system monitor HD 2DAttachment for consumer (SLR) photo camera External 55" 4K 3D video monitor, with mobile cartIntraoperative FluorescenceBLUE 400INFRARED 800INFRARED 800 Compact INFRARED 800 with FLOW 800YELLOW 560Connectivity / Data Manage- mentDICOM module for image and video data transfer from / to PACS. Patient management by modality worklist management.Shared Network Data storage WLAN option, with WiFi Hotspot Navigation Interface Standard Navigation Interface ExtendedAccessories ZEISS QEVO and QEVO ECU12.5x magnetic wide field eyepieces with integrated eyecups Stereo co-observation tubeFoldable Tube f170 / f260, including the PROMAG function for additional 50 % magnification and integrated rotate functionTiltable binocular tube, swivel range 180°, focal length f = 170 mm14-function, wired foot control panel 14-function, wireless foot control panel 2-function foot switch Mouth switch3-step magnification changerApochromatic Optics Motorized focus; Varioskop ® with working distance 200 – 625 mmMotorized zoom; zoom ratio 1:6, magnification factor y = 0.4x – 2.4x10x magnetic wide field eyepieces with integrated eyecupsAutoFokus with 2 visible laser dots, automatic mode with magnetic brakesIllumination 2 x 300 W Xenon, with automatic lamp exchange Automatic Iris Control for adjusting the illumination to the field of view Individual light threshold settingFocus Light Link: working distance controlled light intensityManual adjustment of diameter of field of illuminationAdditional illumination beam to brighten up shadows, motorizedSystem OperationMultifunctional programmable handgrips Magnetic clutches for all system axes Central user interface with full-screen video XY robotic movement in 6 axes (variable speed)Active dampingManual and motorized PointLock function with variable speed PositionMemoryMotorized XY lateral movement with variable speedMultiVision System (HD), with shutter controlSystem Setup AutoBalanceAutoDrape – air evacuation system 1Park Position Drape PositionVideo Integrated 3-chip Full HD video camera, 1080p 24" HD video touchscreen on extendable arm, 16:9 aspect ratioIntegrated still image capturing both on HDD and USB-mediaConnectivity / Data Manage- ment Video-in for external HD video sources Remote diagnosis via internet / VPN Sterile DrapeZEISS SMARTDRAPE1Available with ZEISS SMARTDRAPE only.22Your needs. Our packages.Select a ZEISS KINEVO 900 built to fit your typical clinical use-cases. ZEISS KINEVO 900 comes with pre-defined packages giving you a head start in planning the most suitable configuration for your specific needs.Interested in digital visualization? Check out the digital package. That’s our commitment to cover you for tomorrow while keeping your present needs into focus.always included always included as INFRARED 800 only optional23S U R . 8733 R e v E P r i n t e d i n t h e U n i t e d S t a t e s . C Z -I V /2019 U n i t e d S t a t e s E d i t i o n . O n l y f o r s a l e i n s e l e c t e d c o u n t r i e s .T h e c o n t e n t s o f t h e b r o c h u r e m a y d i f f e r f r o m t h e c u r r e n t s t a t u s o f a p p r o v a l o f t h e p r o d u c t o r s e r v i c e o f f e r i n g i n y o u r c o u n t r y . P l e a s e c o n t a c t o u r r e g i o n a l r e p r e s e n t a t i v e s f o r m o r e i n f o r m a t i o n . S u b j e c t t o c h a n g e s i n d e s i g n a n d s c o p e o f d e l i v e r y a n d d u e t o o n g o i n g t e c h n i c a l d e v e l o p m e n t . R o b o t i c V i s u a l i z a t i o n S y s t e m , K I N E V O , Q E V O , F L O W , A u t o D r a p e , V a r i o s k o p a n d V i s i o n G u a r d a r e e i t h e r t r a d e m a r k s o r r e g i s t e r e d t r a d e m a r k s o f C a r l Z e i s s M e d i t e c A G .© C a r l Z e i s s M e d i t e c A G , 2019. A l l r i g h t s r e s e r v e d .View of the cerebellar tonsils and medulla. Image courtesy of Dr. Robert F. Spetzler, Barrow Neurological Institute, Phoenix, Arizona, USA. (Cover page)View onto cerebellum and lower cranial nerves. Image courtesy of Dr. Robert F. Spetzler, Barrow Neurological Institute, Phoenix, Arizona, USA. (Page 2) Front temporal area for STA-MCA bypass procedure. Image courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 2)View onto optic nerve and internal carotid artery. Image courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 4)Image-guided surgery. Image courtesy of BrainLab AG (Page 6 and 7)View onto spinal cord dura. Image courtesy of Dr. Robert F. Spetzler, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 8 and 9)Small view of the cerebellum through the Retrosigmoid Approach. Image courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 10)Left mini-pterional approach for clipping an aneurysm. Image courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA (page 11)View onto corpus callosum and septum pellucidum. Image courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 12)Transnasal transspenoidal for re-exploration and excision of recurrent pituitary Macroadenoma with possible abdominal fat. Image courtesy of Dr. William White, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 13)Right temporal Craniotomy for AVM. Image courtesy of Dr. Robert F. Spetzler, Barrow Neurological Institute, Phoenix, Arizona, USA (Page 14 and 15)Glioma surgery using BLUE 400. Image courtesy of Prof. Dr. Walter Stummer, University Clinic, Münster, Germany (Page 15)Left-temporal craniotomy for tumor resection with YELLOW 560. Image Courtesy of Dr. Peter Nakaji, Barrow Neurological Institute, Phoenix, Arizona, USA. (Page 15)Carl Zeiss Meditec AG Goeschwitzer Strasse 51–52 07745 Jena Germany/med /kinevoCarl Zeiss Meditec, Inc.5160 Hacienda Drive Dublin, CA 94568USA/med/us。
奥斯特拉科技 NexiusZoom EVO 电子显微镜产品说明书

•NexiusZoom EVO ENZ-5313•ENZ-5302 / ENZ-5303paredes, iluminación de pacientes, estabilización de presiónde aire y revestimientos de succión, APL evita el crecimiento de microbios no•ENZ-1902-AP•ENZ-9505450360º| C I E N C I A D E L O S M A T E R I A L E S || C I E N C I A S D E L A V I D A || E D U C A C I ÓN |E STAT I V O S• S oportes ergonómicos con columna o piñón/cremallera con iluminación incidente y transmitida LED 3W de intensidad regulable (modelos –P y –S)• S oporte ergonómico de columna con iluminación incidente de dos brazos LED 3W y transmitida LED 3W de intensidad regulable (modelos –PG)• S oporte ergonómico de columna con iluminación incidente y transmitida con espejo orientable LED 3W de intensidad regulable (modelos –M) • S oporte universal ergonómico de un brazo o dos brazos, sin iluminación (modelos –U, -B y –BC)• S oporte articulado son base pesada o mordaza mesa, sin soporte de cabezal, sin iluminación (modelos –A y –AP)Todos los soportes de columna o piñón/cremallera se suministran con dos pinzas sujeta muestras. Fabricados en metal y con recubrimiento de pintura de alta resistenciaP L AT I N A O P C I O N A LPlatina móvil X-Y opcional de 180 x 155 mm . con desplazamiento de 76 x 55mm. y base transparente compatible con todos los modelos de NexiusZoom y NexiusZoom EVO con estativo de columna o brazo fijo. Solo disponible con unidades nuevas de microscopio (requiere ser montada en fábrica). Vea imagen: ENZ-9505I L U M I N AC I ÓNLos modelos con estativo de columna (-P) o brazo fijo (-S) incluyen iluminación transmitida e incidente LED 3 W con fuente de alimentación interna 100-240 VAmbos iluminadores se pueden utilizar de manera simultánea y disponen de regulación de intensidad independiente. Los modelos con estativode columna (-M) incluyen iluminación transmitida LED 3W con espejo de desviación e incidente LED 3W con fuente de alimentación 100-240V. Los modelos con estativo de columna (-PG) incluyen iluminación transmitida LED 3W e incidente mediante dos flexos LED orientablesM Para aplicaciones de inspección y ensamblaje. La descarga electroestática (ESD) es un flujo no deseado de electricidad entre dos objetos cargados de electricidad. ESD puede causar un amplio rango de daños permanentes en componentes electrónicos de estado sólidoPor este motivo Euromex introduce en la gama NexiusZoom modelos con protección ESD. El cuerpo del microscopio estereoscópico y el soporte han sido tratados con una pintura especial que previene la descargas electroestáticas haciendo de estos modelos la mejor elección para trabajar en ambientes sensibles a la electricidad estáticaE M Incluye cable de alimentación y fusible de recambio (modelos que incorporeniluminación), funda de protección y manual de instrucciones. Caja de poliestireno™25639346339103180178220259.5310.5| C I E N C I A D E L O S M A T E R I A L E S || C I E N C I A S D E L A V I D A |FIC HA T ÉC NI C A| E D U C A C I ÓN |M O D E L O S N E X I U S Z O O M 0.67-4.5 (W F10X /22M M )M O D E L O S N E X I U S Z O O M E V O 0.65-5.5 (W F10X /23M M )M O D E L O SBinoTrinoSoporte de columna (-P)Soporte piñón/cremallera (-S)Soporte universal un brazo (-U)Soporte universal doble brazocon base(-B)Soporte universal doble brazo con mordaza mesa (-BC)Brazo articulado con mordaza mesa (-A)Brazo articulado con base pesada(-AP)Soporte con doble guía de iluminación incidente (-PG)Soporte con iluminación transmitida espejo orientable(-M)Peso (kg)ENZ-1902-P •• 5.0ENZ-1902-PG •••5.1ENZ-1902-M •••4.9ENZ-1902-S ••4.9ENZ-1902-U ••15.6ENZ-1902-B ••22.1ENZ-1902-BC ••10.5ENZ-1902-A ••8.6ENZ-1902-AP ••20.7ENZ-1903-P •• 5.2ENZ-1903-PG •••5.3ENZ-1903-M •••5.1ENZ-1903-S ••5.1ENZ-1903-U ••15.7ENZ-1903-B ••22.2ENZ-1903-BC ••10.6ENZ-1903-A ••8.7ENZ-1903-AP••20.8M O D E L O SBinoTrinoSoporte de columna (-P)Soporte piñón/cremallera(-S)Soporte universal un brazo (-U)Soporte universal doble brazo con base (-B)Soporte universal doble brazo con mordaza mesa (-BC)Brazo articulado con mordaza mesa (-A) Brazo articulado con base pesada (-AP)Soporte con doble guía de iluminación incidente (-PG)Soporte coniluminación transmitida espejo orientable(-M)Peso (kg)ENZ-1702-P •• 5.0ENZ-1702-PG •••5.1ENZ-1702-M •••4.9ENZ-1702-S ••4.9ENZ-1702-U ••15.6ENZ-1702-B ••22.1ENZ-1702-BC ••10.5ENZ-1702-A ••8.6ENZ-1702-AP ••20.7ENZ-1703-P •• 5.2ENZ-1703-PG •••5.3ENZ-1703-M •••5.1ENZ-1703-S ••5.1ENZ-1703-U ••15.7ENZ-1703-B ••22.2ENZ-1703-BC ••10.6ENZ-1703-A ••8.7ENZ-1703-AP••20.8D I ME N SI O N E SLos modelos NexiusZoom EVO ahora están equipados click-stopsENZ-8903 ENZ-8904 ENZ-8905 ENZ-8907 ENZ-8915 ENZ-8920 CO M PAT I B I L D D E L A S L E N T O B J E T I V OM O D E L O S Aumentos 0,3x Aumentos 0,4x Aumentos 0,5x Aumentos 0,75x Aumentos 1,5x Aumentos 2xENZ-9000/9005•••NexiusZoom-P, -M, -PG•••NexiusZoom-P-ESD•••NexiusZoom-S•NexiusZoom-S-ESD•••ENZ-1903-B•ENZ-1902-BC•ENZ-1903-S•ENZ-1902-M•ENZ-1902-PG•ENZ-1902-P•ENZ-1902-U• ENZ-1903-U-ESD• ENZ-1903-B-ESD• ENZ-1903-P-ESD• ENZ-1903-S-ESD•ENZ -9005•ENZ -9000•ENZ-9095sin soporte de cabezal con de iluminación (estativo -U)incidente y transmitida por (disponible para 110V y 230V)stativo de columna con iluminación LED incidente y transmitidaEl ELE-5212 en dos configuraciones diferentes EuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•****************•。
ZEISS ARTEVO 800数字眼科显微镜说明书

25% better
light transmission 3
Dramatically reduced light intensity Provide your patients with more comfort during surgery. The DigitalOptics of the ZEISS ARTEVO 800 offers the choice to operate at reduced light intensity – while an uncompromised level of brightness is maintained.
Jean-François Korobelnik, MD CHU de Bordeaux, France
4
25% higher
resolution 1
Excellent resolution and natural colors Experience natural colors when you view the surgical field. The optical system is optimized to produce remarkably clear images.
Khalid Al-Sabti, MD, FRCS Kuwait Specialized Eye Center, Kuwait
ZEISS ARTEVO 800
Cloud Connectivity allows surgeons to access essential information no matter where they are – and when they want. So whether it’s in the OR during surgery, in the office reviewing a procedure, or in the classroom with students, Cloud Connectivity ensures the data is within easy reach and improves your workflow.
NexiusZoom (EVO)立体显微镜产品说明书

NZ.1903-SBinocularTrinocularPillar standRack & pinion standUniversal standBoom standArticulated arm standWeight (kg)NZ.1702-P ••5.0NZ.1702-S ••4.9NZ.1702-U ••15.6NZ.1702-B ••22.1NZ.1702-A ••8.6NZ.1703-P ••5.2NZ.1703-S ••5.1NZ.1703-U ••15.7NZ.1703-B ••22.2NZ.1703-A••8.7M O D E L S N E X I U S Z O O M E V O 0.65-5.5 (W F10X /23M M )BinocularTrinocularPillar standRack & pinion standUniversal standBoom standArticulated arm standWeight(kg)NZ.1902-P ••5.0NZ.1902-S ••4.9NZ.1902-U ••15.6NZ.1902-B ••22.1NZ.1902-A ••8.6NZ.1903-P ••5.2NZ.1903-S ••5.1NZ.1903-U ••15.7NZ.1903-B ••22.2NZ.1903-A••8.7M O D E L S N E X I U S Z O O M 0.67-4.5 (W F10X /22M M )M AG N I F I C AT I O N SNexiusZoom standard & ESD Working distance and field of view with standard HWF 10x / 22 High Wide Field eyepiecesZoom indicationObjective 1x (standard)Working distance 110 mm Auxiliary lens 0.5x Working distance 165 mm Auxiliary lens 0.75x Working distance 120 mm Auxiliary lens 1.5x Working distance 45 mm Auxiliary lens 2x Working distance 30 mm TotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mm0.67 6.732.8 3.3565.7 5.043.810.121.913.416.40.77.031.4 3.562.9 5.341.910.521.014.015.70.88.027.5 4.055.0 6.036.712.018.316.013.81.010.022.0 5.044.07.529.315.014.720.011.01.515.014.77.529.311.319.622.59.830.07.32.020.011.010.022.015.014.730.07.340.0 5.53.030.07.315.014.722.59.845.0 4.960.0 3.74.040.0 5.520.011.030.07.360.0 3.780.0 2.84.545.04.922.59.833.86.567.53.390.02.4NexiusZoom EVO Working distance and field of view with standard HWF 10x / 23 High Wide Field eyepiecesZoom indicationObjective 1x (standard)Working distance 110 mm Auxiliary lens 0.5x Working distance 165 mm Auxiliary lens 0.75x Working distance 120 mm Auxiliary lens 1.5x Working distance 45 mm Auxiliary lens 2x Working distance 30 mm TotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mmTotalMagnificationsField of view in mm0.65 6.535.4 3.2570.8 4.947.29.823.613.017.70.77.032.9 3.565.7 5.343.410.521.914.016.40.88.028.8 4.057.5 6.038.312.019.216.014.41.010.023.0 5.046.07.530.715.015.320.011.51.515.015.37.530.711.320.422.510.230.07.72.020.011.510.023.015.015.330.07.740.0 5.83.030.07.715.015.322.510.245.0 5.160.0 3.84.040.0 5.820.011.530.07.760.0 3.880.0 2..94.545.0 5.122.510.233.8 6.867.5 3.490.0 2.65.555.04.227.58.441.35.682.52.81102.1NZ.1902-UNZ.1902-P100330 450360º360º340º310max1.000 maxFrom 0 to 295 max40NZ.1902-ANZ.1903-BNZ.1902-SNZ.1903-P-ESDNZ.1903-U-ESDNZ.1903-P-ESDE S D S AF E M O D E L SBinocularTrinocularPillar standRack & pinion standUniversal standBoom standArticulated armstandAntistatic ESDWeight (kg)NZ.1902-P-ESD ••• 5.0NZ.1902-S-ESD ••• 4.9NZ.1902-U-ESD •••15.6NZ.1902-B-ESD •••22.1NZ.1903-P-ESD ••• 5.3NZ.1903-S-ESD •••5.1NZ.1903-U-ESD •••15.7NZ.1903-B-ESD•••22.2NexiusZoom ESDEuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•F+31(0)263232833•****************•ACCE SS O R I E S A N D SPA R E PA R T SNZ.5302 NexiusZoom binocular head with eyepieces NZ.5303 NexiusZoom trinocular head with eyepieces NZ.5312 NexiusZoom EVO binocular head with eyepieces NZ.5313 NexiusZoom EVO trinocular head with eyepieces NZ.6010 Pair of HWF 10x / 22 mm eyepieces NZ.6015 Pair of HWF 15x / 16 mm eyepieces NZ.6020 Pair of HWF 20x / 12 mm eyepiecesNZ.6110 HWF 10x / 22 mm eyepiece with micrometerNZ.6210 Pair of HWF 10x / 23 mm eyepieces (only suitable for the EVO)NZ.6099 Pair of eyecupsNZ.8903 A uxiliary lens 0.3x (not suitable for NZ.1902-S, NZ.1903-S, NZ.1902-S-ESD and NZ.1903-S-ESD)NZ.8905 A uxiliary lens 0.5x. Working distance 165 mm (not suitable forNZ.1902-S and NZ.1903-S)NZ.8907 Auxiliary lens 0.75x. Working distance 120 mm NZ.8915 Auxiliary lens 1.5x. Working distance 45 mmNZ.8920 A uxiliary lens 2.0x. Working distance 30 mm (not suitable forNZ.1902-S and NZ.1903-S)NZ.8950 Protection glass for NexiusZoom headNZ.9010 E rgonomic rack & pinion stand with transmitted and incident LEDilluminatorsNZ.9015 E rgonomic pillar stand with transmitted and incident LEDilluminatorsNZ.9020 Universal (single arm) stand without NexiusZoom head holder NZ.9030 Boom (double arm) stand without NexiusZoom head holder NZ.9090 NexiusZoom head holder (for NZ.9020 and NZ. 9030)NZ.9025 A rticulated arm stand with table clamp |(without NexiusZoomhead holder)NZ.9027 A rticulated arm stand with heavy stand (without NexiusZoomhead holder)NZ.9081 NexiusZoom head holder (for articulated arm stand NZ.9025)NZ.9520 P olarization kit for NexiusZoom: 360° rotatable round stage withbuilt-in polarization filter (NZ.9524) + analyzer in mount to be screwed under head (NZ.9525)NZ.9524 360° rotatable round stage with built-in polarization filter forNexiusZoomNZ.9525 360° rotatable analyser in mount to be screwed under head ofNexiusZoomAE.5168-NZ Heating stage with PID controller up to 50oC NZ.9950 Standard opaque stage plate NZ.9956 Black/white stage plate NZ.9570 Pair of object clamps for stageNZ.9572 Adjustable GEM object clamp for NexiusZoom (EVO)NZ.9833 C -mount adapter with 0.33x lens for 1/3” cameras (suitable fortrinocular models)NZ.9850 C -mount adapter with 0.5x lens for 1/2” cameras (suitable fortrinocular models)50.876 Dark field attachmentAE.5130 U niversal SLR camera adapter with 2x projection lens for23.2 mm tubes. Need T2 adapterAE.5025 T2 adapter for Nikon D digital SLR camerasAE.5040 T 2 adapter for Canon EOS digital SLR camerasOther T2 adapterson requestLE.1974 R ing illuminator with 72 LEDs with adjustable light intensity.External mains adapter 100-240 V. With segment controller. Brightness of 21.000 Lux at height of 100 mm and color temperature of 6.500K. Mounting diameter between 25-61 mmLE.1973 R ing illuminator with 144 LEDs with adjustable light intensity.External mains adapter 100-240 V. With segment controller. Brightness of 23.000 Lux at height of 100 mm and color temperature of 6.500K. Mounting diameter between 25-61 mmAE.1112 O bject micrometer 50 mm (divided in 500 parts on glass slide76 x 26 mm)。
NexiusZoom (EVO)双重3W LED双重灯光立体显微镜产品说明书

NZ.1903-SAuxiliary lenses 0.3x, 0.5x, 0.75x, 1.5x and 2.0x are alsoavailable for the standard NexiusZoom and for theNexiusZoom EVO NZ.5313NZ.9505100330450360º360º340º310max1.000 maxFrom 0 to 295 max40NZ.1902-ANZ.1902-APS TA N D• E rgonomically designed pillar or rack & pinion stand with 3W incident and 3W transmitted LED illuminations• E rgonomically designed pillar stand with two 3W goose-neck type incident LED illuminations on each side and a 3W transmitted LED illumination • E rgonomically designed universal or boom stands, without illumination (-U, -B and BC stands)• A rticulated arm stand for table mounting or with heavy desktop stand, both without head holder, without illumination (-A and -AP stands)All pillar and rack & pinion stands are supplied with two object clamps. Alloy metal cast, hardened coating.S TAG E180 x 155mm X-Y mechanical stage with 76 x 55mm translation stage and transparent glass plate for NexiusZoom, fixed on stage of microscope. Only available with new microscopes(due to fixing), so it has to be ordered with the purchase of a microscope (See picture: NZ.9505)I L L U M I N AT I O N3 W transmitted and incident LED illuminators with internal power supply 100-240 V. Both illuminators can be used simultaneously and the light intensities can be adjusted separately. The universal single or double arm stands and the articulated stands can be equipped with the ring illuminators LE.1974 and LE.1973 with respectively 72 or 144 power LEDs controlled in segments, ideal for creating or lifting shadesE S D S AF E M I C R O S CO P E SFor inspection and assembly applications. Electrostatic discharge (ESD) is the unwanted sudden flow of electricity between two electrically charged objects. ESD can cause a range of harmful effects as well as permanent damage to solid state electronics componentsEuromex therefore introduces electrostatic protected microscopes in theNexiusZoom range. The body and stand of the microscope are coated with a special static dissipative paint eliminating harmful electrostatic discharges making the microscopes suitable for all static-sensitive environmentsPAC K AG E CO N T E N TSupplied with power cord, dust cover, a spare fuse and user manual. All packed in a polystyrene boxN E X I U S Z O O M E V O 0.65-5.5 (W F 10X /23M M )N E X I U S Z O O M A N D N E X I U S Z O O M E S D 0.67- 4.5 (W F 10X /22M M )M O D E L SBinocularTrinocularPillar standRack & pinionstandUniversal standBoom standArticulated arm standGooseneck dual LEDAnti static ESDMirror LEDWeight (kg)NZ.1902-P•• 5.0NZ.1902-P-ESD•••5.0NZ.1902-PL•••5.1NZ.1902-M•••4.9NZ.1902-S•• 4.9NZ.1902-S-ESD•••4.9NZ.1902-U••15.6NZ.1902-U-ESD•••15.6NZ.1902-B••22.1NZ.1902-B-ESD•••22.1NZ.1902-BC (1)••10.5NZ.1902-A••8.6NZ.1902-AP(2)••20.7NZ.1903-P•• 5.2NZ.1903-P-ESD•••5.2NZ.1903-PL•••5.3NZ.1903-M•••5.1NZ.1903-S•• 5.1NZ.1903-S-ESD•••5.1NZ.1903-U••15.7NZ.1903-U-ESD•••15.7NZ.1903-B••22.2NZ.1903-B-ESD•••22.2NZ.1903-BC (1)••10.6NZ.1903-A••8.7NZ.1903-AP(2)••20.8M O D E L SBinocular Trinocular Pillar standRack & pinionstand Universal standBoom standArticulated arm stand Gooseneck dualLEDMirror LED Weight (kg)NZ.1702-P •• 5.0NZ.1702-PL •••5.1NZ.1702-M •••4.9 NZ.1702-S ••4.9NZ.1702-U ••15.6NZ.1702-B ••22.1NZ.1702-BC (1)••10.5NZ.1702-A ••8.6NZ.1702-AP (2)••20.7NZ.1703-P •• 5.2NZ.1703-PL •••5.3NZ.1703-M ••5.1NZ.1703-S ••5.1NZ.1703-U ••15.7NZ.1703-B ••22.2NZ.1703-BC (1)••10.6NZ.1703-A ••8.7NZ.1703-AP (2)••20.8(1) Boom stand model with tabletop clamp(2)Articulated stand model with heavy desktop base plate(1) Boom stand model with tabletop clamp(2)Articulated stand model with heavy desktop base plateM AG N I F I C AT I O N SNexiusZoom standard& ESD Working distance and field of view with standard HWF 10x / 22 High Wide Field eyepiecesZoom indicationObjective 1x (standard)Working distance 110 mmAuxiliary lens 0.5xWorking distance 165 mmAuxiliary lens 0.75xWorking distance 120 mmAuxiliary lens 1.5xWorking distance 53 mmAuxiliary lens 2xWorking distance 30 mm TotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mm0.67 6.732.8 3.3565.7 5.043.810.121.913.416.40.77.031.4 3.562.9 5.341.910.521.014.015.70.88.027.5 4.055.0 6.036.712.018.316.013.81.010.022.0 5.044.07.529.315.014.720.011.01.515.014.77.529.311.319.622.59.830.07.32.020.011.010.022.015.014.730.07.340.0 5.53.030.07.315.014.722.59.845.0 4.960.0 3.74.040.05.520.011.030.07.360.0 3.780.0 2.84.545.0 4.922.59.833.86.567.5 3.390.0 2.4 NexiusZoom EVO Working distance and field of view with standard HWF 10x / 23 High Wide Field eyepiecesZoom indicationObjective 1x (standard)Working distance 110 mmAuxiliary lens 0.5xWorking distance 165 mmAuxiliary lens 0.75xWorking distance 120 mmAuxiliary lens 1.5xWorking distance 53 mmAuxiliary lens 2xWorking distance 30 mm TotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mmTotalMagnificationsField of viewin mm0.65 6.535.4 3.2570.8 4.947.29.823.613.017.7 0.77.032.9 3.565.7 5.343.410.521.914.016.40.88.028.8 4.057.5 6.038.312.019.216.014.41.010.023.0 5.046.07.530.715.015.320.011.51.515.015.37.530.711.320.422.510.230.07.72.020.011.510.023.015.015.330.07.740.0 5.83.030.07.715.015.322.510.245.0 5.160.0 3.84.040.05.820.011.530.07.760.0 3.880.0 2..94.545.0 5.122.510.233.86.867.5 3.490.0 2.65.555.0 4.227.58.441.3 5.682.5 2.8110 2.1NZ.1902-P NZ.1902-UNZ.1902-SNZ.1903-BNZ.1903-M NZ.1903-PLNZ.1903-P-ESDNZ.1903-U-ESDNZ.1903-P-ESD E S D S A F E M O D E L SBinocularTrinocularPillar standRack & pinion standUniversal standBoom standArticulated armstandAntistatic ESDWeight (kg)NZ.1902-P-ESD ••• 5.0NZ.1902-S-ESD ••• 4.9NZ.1902-U-ESD •••15.6NZ.1902-B-ESD •••22.1NZ.1903-P-ESD ••• 5.3NZ.1903-S-ESD •••5.1NZ.1903-U-ESD •••15.7NZ.1903-B-ESD•••22.2NexiusZoom ESDEuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•F+31(0)263232833•****************•ACCE SS O R I E S A N D SPA R E PA R T SNZ.5302 NexiusZoom binocular head with eyepieces NZ.5303 NexiusZoom trinocular head with eyepieces NZ.6010 Pair of HWF 10x / 22 mm eyepieces NZ.6015 Pair of HWF 15x / 16 mm eyepieces NZ.6020 Pair of HWF 20x / 12 mm eyepiecesNZ.6110 HWF 10x / 22 mm eyepiece with micrometerNZ.6210 Pair of HWF 10x / 23 mm eyepieces (only suitable for the EVO)NZ.6099 Pair of eyecupsNZ.8903 A uxiliary lens 0.3x for NexiusZoom. Not suitable for-S, -P -M stand modelsNZ.8905 A uxiliary lens 0.5x. Working distance approx. 165 mm.Not suitable for -S and -M stand modelsNZ.8907 Auxiliary lens 0.75x. Working distance approx. 120 mm NZ.8915 Auxiliary lens 1.5x. Working distance approx. 53 mm NZ.8920 A uxiliary lens 2.0x. Working distance approx. 30 mmNot suitable for the S-stand modelNZ.8950 Protection glass for NexiusZoom headNZ.9010 E rgonomic rack & pinion stand with 3 W transmitted and incidentLED illuminatorsNZ.9015 E rgonomic pillar stand with 3 W transmitted and incident LEDilluminatorsNZ.9017 E rgonomically designed pillar stand with two 3 W goose-necktype incident LED illuminations on each side and a 3 W transmitted LED illuminationNZ.9020 Universal (single arm) stand without NexiusZoom head holder NZ.9030 Boom (double arm) stand without NexiusZoom head holder NZ.9032 B oom (double arm) stand with table clamp (without NexiusZoomhead holder NZ.9090)NZ.9042 E rgonomic pillar stand with rotating mirror and transmitted andincident 3 W LED illuminationNZ.9090 NexiusZoom head holder (for NZ.9020, NZ. 9030 and NZ. 9032)NZ.9095 N exiusZoom head holder with fine coarse (for NZ.9020, NZ. 9030and NZ. 9032)NZ.9095-ADD NexiusZoom head holder with fine coarse ADD-ON forN Z.9020, NZ. 9030 and NZ.9032 Only available with new microscopesNZ.9025 A rticulated arm stand with table clamp |(without NexiusZoomhead holder)NZ.9027 A rticulated arm stand with heavy stand (without NexiusZoomhead holder)NZ.9081 N exiusZoom head holder (for articulated arm stand NZ.9025 andNZ.9027)NZ.9520 P olarization kit for NexiusZoom: 360° rotatable round stage withbuilt-in polarization filter (NZ.9524) + analyzer in mount to be screwed under head (NZ.9525)NZ.9524 360° rotatable round stage with built-in polarization filter forNexiusZoomNZ.9525 360° rotatable analyser in mount to be screwed under head ofNexiusZoom. Not suitable for use in combination with auxiliary lensesAE.5168-NZ Heating stage with PID controller up to 50oC. Only with thepurchase of a new microscopeNZ.9950 Standard opaque stage plate NZ.9956 Black/white stage plate NZ.9570 Pair of object clamps for stageNZ.9572 Adjustable GEM object clamp for -P, -PL and -S stands50.876 Dark field attachment (for -S and -P stands)NZ.9833 C -mount adapter with 0.33x lens for 1/3” cameras (suitable fortrinocular models)NZ.9850 C -mount adapter with 0.5x lens for 1/2” cameras (suitable fortrinocular models)AE.5130 U niversal SLR camera adapter with 2x projection lens for23.2 mm tubes. Need T2 adapterAE.5025 T2 adapter for Nikon D digital SLR camerasAE.5040 T 2 adapter for Canon EOS digital SLR camerasOther T2 adapterson requestLE.1974 R ing illuminator with 72 LEDs with adjustable light intensity.External mains adapter 100-240 V. With segment controller. Brightness of 21.000 Lux at height of 100 mm and color temperature of 6.500K. Mounting diameter between 25-61 mmLE.1973 R ing illuminator with 144 LEDs with adjustable light intensity.External mains adapter 100-240 V. With segment controller. Brightness of 23.000 Lux at height of 100 mm and color temperature of 6.500K. Mounting diameter between 25-61 mmAE.1112 O bject micrometer 50 mm (divided in 500 parts on glass slide76 x 26 mm)。
微观显微镜使用指南说明书

How Do I Use My MicroscopeBefore you use your microscope, make sure that the table, desk or surface that you place it on is stable and is not subject to vibration. If the microscope needs to be moved, hold it by the arm and base while carefully transferring it. Once the microscope is in a suitable location and the batteries are installed, check the light source to make sure that it illuminates. Use a microfiber cleaning cloth to gently wipe the lenses off. If the stage is dirty with dust or oil, carefully clean it off. Make sure that you only raise and lower the stage using the focus adjustment knob.How Do I Operate The Illumination?Locate the mirror/light on the base of the microscope. Flip the mirror/light to the “on” position (with the light facing up) and the light will illuminate. This microscope is equipped with an incandescent light that illuminates the specimen from below. The color filter wheel is located in the middle of the microscope stage. The filters help you when you observing very bright or clear specimens. Using these filters, you can choose various brightness levels and colors. This helps you better recognize the components of colorless or transparent objects (e.g. sea salt).How Do I Adjust My Microscope Correctly?Place the microscope in a suitable location as described above, and sit in a comfortable viewing position. Always start each observation with the lowest magnification. Adjust the distance of the microscope stage so that the stage is in the lowest position — farthest away from the turret head. Turn the objective turret until it clicks into place at the lowest magnification (Objective: 5x/Magnification: 100x). Note: Before you change the objective setting, always make sure the microscope stage is farthest away from the turret by rotating the focus knob. Separating the stage and turret by rotating the focus knob will avoid causing damage to the specimen slide or microscope. When starting an observation, always start with the 5x objective in the rotating head.How Do I Observe The Specimen?Sitting in your location with adequate illumination, the following basic rules should be observed. Start with a simple observation at the lowest magnification. Position the object or specimen in the middle of the stage under the stage clips, center over the lower light. Focus the image by rotating the focus knob until a clear image appears in the eyepiece.Place the prepared slide directly under the objective on the microscope stage and secure it with the stage clips. The prepared slide should be located directly over the lowerillumination. Look through the eyepiece and carefully turn the focus knob until the image appears clear and sharp. Now you can select a higher magnification by rotating to the objective turret. Higher levels of magnification can be achieved by turning the objective turret to a higher setting (400x or 900x). Following this procedure creates a steady increase of magnification without overpowering the view of the object. The following magnification order should be used: 100x, 400x then 900x. Each time the magnification changes (due to the objective change), the image sharpness must be readjusted with the focus knob. When doing this, be careful because if you move the microscope stage too quickly, the objective and the slide could come into contact and cause damage to the slide or microscope.For transparent objects (e.g. sea salt), light is projected by the lower light traveling from below the stage, through the objective and eyepiece, and finally into your eye. This process of light transmission is known as microscopy. Many micro-organisms found in water, plant components and the smallest animal parts are transparent in nature. Opaque specimens, on the other hand, will need to be prepared for viewing. Opaque specimens can be made transparent by a process of treatment and penetration with the correct materials (media), or by slicing. Y ou can read more about creating specimens in the enclosed microscope experiments booklet.MAGNIFICATION GUIDE:NOTE:THE HIGHEST MAGNIFICATION IS NOT ALWAYS THE BEST FOR EVERY SPECIMEN!TROUBLESHOOTING GUIDE:©2020 National Geographic Partners LLC. All rights reserved. NATIONAL GEOGRAPHIC and Yellow Border Design are trademarks of theNational Geographic Society, used under license.©2020 Explore Scientific, LLC.1010 S. 48th Street, Springdale AR 72762All rights reserved. | 866.252.3811Made in China CONTENTS AND COLORS MAY VARYCONFORMS TO THE SAFETY REQUIREMENTS OF ASTM F963V042020CHOKING HAZARD — Small parts.Not for children under 8 years.WARNING:FUNCTIONAL SHARP POINT — Not for children under 8 years.WARNING:900X MICROSCOPE SETINSTRUCTION MANUAL*Not suitable for children under 8 years of age. Contains functional sharp points.Microscope Parts: 01. Eyepiece 02. Focus Knob03. Stage with Color Filters 04. Stage Clips05. Objective Turret (5x, 20x, 45x)06. Illumination On/Off Switch and Mirror 07. Rubber Base and Battery Case 08. Microscope Arm09. (5) Prepared Slides and (7) Blank Slides with Slide Case 10. (7) Slide Covers/Labels 11. (2) Collection Vials 12. T est Tube 13. Petri Dish14. Scalpel / Needle* / Tweezers / Stirring Rod 15. Slicer16. Blue Dye / Red Dye / Sea Salt / Brine Shrimp Eggs 17. HatcheryNOT INCLUDEDX 2Do not mix old and new batteries. Do not mix alkaline,standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, etc.) batteries.Non-rechargeable batteries are not to be recharged. Please recycle batteries responsibly.01020306070812131415161780-50101EN8+09091011WHAT’S INCLUDED:Observe, Investigate, Discover!When you want to take your investigations to the cellular level, the 900x Microscope is ready to reveal the hidden details of the world around you. Everyday things like sand, onion skin, hair and pollen will show theirextraordinary sides when viewed at magnifications ranging from 100x to 900x. T o jump start your observations, the set comes with prepared specimens, collection tools and an experiment guide.0504。
EVO18使用说明

Carl Zeiss SMT - Nano Technology Sy st e ms EVO® MA /LS 系列扫描电子显微镜使用说明ZEISS EVO® MA/LS系列扫描电子显微镜使用说明Contents目录Section 1. General Information 第一章综合信息 (1)1.Abstract 概要 (1)2. Important Information 重要信息 (2)3. Safety Precautions (Warnings and Cautions) 安全措施(警告和注意) (2)4. Notes about the Mains Supply 关于主电源的说明 (4)5. Use of Liquid Nitrogen 液氮的使用 (4)6. Do’s and Don’ts 可做和不可做 (6)Section 2. Basic design Principles of the SEM 第二章SEM 的基本设计原理 (7)1. Introduction 介绍 (7)2. Resolution. 分辨率 (8)3. Depth of field 景深 (9)4. Microanalysis. 微区分析 (10)5. Beam Specimen interactions. 电子束与样品的相互作用 (12)6. Detectors 探测器 (14)7. How it works 如何工作 (16)8. Specimen preparation guidance. 样品制备指南 (21)Section 3. Operation of the SEM 第三章SEM的操作 (25)1. Consider the properties of the specimen 样品性质的考虑 (25)2. Guide to SEM Operating Parameters SEM工作参数指南 (26)2.1 Conductive specimens 导电样品 (26)2.2 Non-conductive specimens 非导电样品 (27)2.3 Imaging wet samples using the Peltier coolstage 使用帕尔贴冷台观察含水样品 (29)3.Sequence Guide to Operation of the SEM SEM操作顺序指南 (31)Section 4. Operation of the SmartSEM®第四章SmartSEM®的使用 (32)1. Introduction (32)1.1. Intended use 预期用途 (32)1.2. About this software 关于本软件 (32)1.3. Safety instructions in this section 本部分中的安全指示 (32)2. Description 描述 (34)2.1. System requirements 系统要求 (34)2.2. Installation 安装 (34)2.3. Principle of operation (34)2.4. SmartSEM® user interface (UIF) SmartSEM®用户界面 (35)2.5. User access levels 用户访问级别 (37)3. First steps 第一步 (38)3.1. Switching on the SEM 开启SEM (38)3.2. Starting the SmartSEM® user interface 启动SmartSEM®用户界面 (39)3.3. Finding your way in the software 在软件中找到您的方式 (41)3.4. Obtaining the first image 获得第一幅图像 (46)3.5. Using the help functions (63)3.6. Closing the SmartSEM®software 关闭SmartSEM®软件 (68)4. Operation 操作 (69)4.1. Controlling the vacuum 控制真空 (69)4.2. Navigating the specimen 样品导航 (75)4.3. Setting SEM conditions 设置电镜条件 (89)4.4. Imaging 成像 (99)4.5. Annotating images 注释图像 (125)4.6. Working with recipes 用配方工作 (135)4.7. Saving and managing images 存储和管理图像 (142)4.8. Customising the SmartSEM®software 定义SmartSEM®软件 (149)5. Troubleshooting 故障处理 (162)5.1. Initialising the stage 初始化样品台 (163)5.2. Changing the joystick TV angle 改变操纵杆TV 角 (164)5.3. Resetting touch alarm (165)Section 5. Appendices 第五章附录 (166)1. Replacement of filament 更换灯丝 (166)2.Table of Pressure Limiting Apertures 压差光栏表 (170)3. An introduction to Macros 宏指令介绍 (171)4.Shortcuts 快捷键 (182)5.Annotation icons 注释栏图标说明 (184)Section 1. General Information 第一章综合信息1.Abstract 概要本使用说明向新用户介绍ZEISS EVO系列扫描电子显微镜(SEM)。
微蓝生物显微镜系列产品技术参数说明书

MB.1001E NF O Q U ESos modelos binoculares tienen tubos inclinados de 45 °, distancia inter-pupilar ajustable entre 48 y 75 mm y un ajuste de ± 5 dioptrías en el tubo izquierdo os modelos trinoculares tienen tubos inclinados de 30 °, la distancia inter-pupilar es ajustable entre 48 y 75 mm y un ajuste de ± 5 dioptrías en el tubo izquierdo l cabezal trinocular tiene un divisor de haz de trayectoria de luz fija (50:50)MB.1051-LCDMB.1155 MB.1153MB.1152 MB.1051I LU M I N AC I ÓN• T odas las versiones monoculares se suministran con una iluminación LED 1W de intensidad ajustable• L as versiones binoculares y trinoculares se suministran con un sistema de iluminación NeoLED ™ 1W de intensidad ajustable• T odos los modelos tienen baterías internas recargables con un cargador de batería externo de 100-240 V / adaptador de redCO N T E N I D O I N C LU I D O• S e suministra con cargador de adaptador de red, filtro blanco, cubierta anti-polvo, manual de usuario y aceite de inmersión de 5 ml para modelos con objetivo S100x. Software incluido para modelos digitales y para los modelos LCD• Todo empacado en una caja de poliestirenoMODELOS DIGI TALESC ÁM A R A• C ámara integrada CMOS USB-2 de 1.3 MP• R esolución máxima de 1272 x 952, profundidad de color de 24 bits, hasta 30 fotogramas por segundo• S e entrega con el software ImageFocus 4, cable USB-2 y un patrón de calibración de 1 mm / 100 partes • La garantía para la cámara es de dos añosS O F T WA R E• E l software ImageFocus 4 de captura y análisis permite guardar imágenes en formatos .jpg, .tif o .bmp, así como videos en formato .avi• L as imágenes se pueden anotar y las mediciones se pueden realizar en imágenes en vivo o capturadas• C ompatible con Windows 7, 8 y 10, configuraciones de 32 y 64 bits • L a versión Mac OS Light también está disponible para capturar imágenes • L as actualizaciones se pueden descargar en nuestro sitio web PA N TA L L A LC DTodos los microscopios MicroBlue LCD vienen con una pantalla LCD de 5.6”• Resolución de la pantalla 640 x 480• Las imágenes y los videos se guardan directamente en la tarjeta SD • R esolución de imagen 2048 x 1536, 1600 x 1200, 1280 x 960, 640 x 480 en formato .JPEG• Resolución video 640 x 480 en formato .AVI• Suministrado con el programa Imagebasic et cable USB.2• Garantía de 2 años para la cámaraP R O G R A M A I M AG E B A S I C• E l programa de captura permite guardar imágenes en formato.jpg y videos en formato .avi• Compatible con Windows 7, 8 et 10, en configuraciones de 32 y 64 bits • L as actualizaciones se pueden descargar desde nuestra página web EuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•F+31(0)263232833•****************•ACCESORIOS Y REPUES TOSMB.6010 Ocular de gran campo WF10x/18 mmMB.6010-P Ocular de gran campo WF10x/18 mm con puntero MB.6010-M Ocular de gran campo WF10x/18 mm micrométrico MB.6015 Ocular de gran campo WF15x/11 mm MB.6020 Ocular de gran campo WF20x/9 mm MB.6099 Pareja de protectores de gomaMB.7004 Objetivo acromático 4x/0.10, para-focal 35 mm MB.7010 Objetivo acromático 10x/0.25, para-focal 35 mm MB.7020 Objetivo acromático 20x/0.40, para-focal 35 mm MB.7040 Objetivo acromático S40x/0.65, para-focal 35 mm MB.7060 Objetivo acromático S100x/1.25, para-focal 35 mm MB.9710 Filtro esmeriladoMB.9900 Maleta de transporte de aluminioAE.9918 Bolsa de microscopio de nylon, dimensiones 26 x 18 x 400 mm MB.9975 Adaptador de red / cargador externo 100-240 Vca / 5 Vcc (50/60 Hz)MB.9981 Recambio 1W LED MB.9991 Recambio 1W NeoLEDM O D E LO SMono Bino TrinoObjetivos máximos Objetivos 4/10/S40xObjetivo S60xObjetivo S100x Platina mecánica X-YLED NeoLED BateríasMB.1001 •3•••MB.1051•4••••MB.1651•4•••••MB.1151•4•••••MB.1052•4••••MB.1652•4•••••MB.1152•4•••••MB.1053•4••••MB.1653•4•••••MB.1153•4•••••M O D E LO SDigital LCD Digital mono Objetivos máximos Objetivos 4/10/S40x Objetivo S60x Objetivo S100x Platina mecánica X-YLED NeoLED BateríasMB.1001-LCD*•3•••MB.1051-LCD*•4••••MB.1055•4••••MB.1655•4•••••MB.1155•4•••••* modelos con pantalla LCDPB.5155 P orta-objetos de 76x26 mm., cantos pulidos(caja de 50 unidades)PB.5157-W P orta-objetos de 76x26 mm., cantos pulidos. Banda blanca(caja de 50 unidades)PB.5157-B P orta-objetos de 76x26 mm., cantos pulidos. Banda azul(caja de 50 unidades)PB.5160 P orta-objetos de 76x26 mm., cantos pulidos. Con cavidad(caja de 10 unidades)PB.5165 C ubre-objetos de 18x18mm., 0.13-0.17 mm.(caja de 100 unidades)PB.5168 C ubre-objetos de 22x22mm., 0.13-0.17 mm.(caja de 100 unidades)PB.5245 Papel de limpieza de lentes (paquete de 100 hojas)PB.5255 Aceite de inmersión, n=1.482 (25 ml.)PB.5274 Alcohol isopropilico 99% (200 ml.)PB.5275 K it de limpieza compuesto por líquido de limpieza de lentes,gamuza, papel de limpieza de lentes, cepillo, pera de aire y bastoncillos de algodón.。
NexiusZoom 立体显微镜产品介绍说明书

Stereo microscopesfor Materials and Life SciencesNexius ZoomThe new standard in microscopyEuromex NexiusZoom stereo microscopes enable you to observe your specimen with the highest precision in three dimensional imagingThese high quality stereo microscopes are perfect for analyzing all kinds of material surfaces and for preparing biological samplesNexiusZoom EVO The interpupillary distance is adjustable between 54 and 75 mm dditional lenses 0.3x, 0.4x, 0.5x, 0.75x, 1.5x and 2.0x are availableAll optics are anti-fungus treated and anti-reflection coated for maximum The newly optimized Greenough Optical System offers more depth of focus without compromising on low distortion and color aberrationESD SAFE MICROSCOPESElectrostatic protected microscopesfor all kinds of industry, inspection andNZ.1903-P-ESDNZ.1903-U-ESDNZ.1903-P-ESD The body and stand of the microscope are coated with a special electrostatic dissipative paint eliminating harmful electrostatic discharges, thus making the microscope suitable for all static-sensitive environmentsElectrostatic discharge (ESD) is the unwanted sudden flow of electricity between two electrically charged objects. ESD can cause a range of harmful effects as well as permanent damage to solid state electronicTo solve this Euromex has introduced electrostaticeliminating harmful electrostatic discharges makes environments. Ideal for all kinds of industry, assembly applicationsthe examination of your gems in perfectdarkfield conditionsfluorescenceLEDhalogenNZ.1702-GEMFThe ergonomic tilting stand allows easyadjustment between 0 and 45ºNZ.1902-GEMLSTANDErgonomic stand with 0 to 45° backwards tilting arm, including 76 mm headholder, suitable for darkfield and brightfield. Built-in 100-240 V power supplySTAGEFlat darkfield stage with clamp object holder, iris diaphragm and incidentillumination. Clamp object holder can be placed on left or right side1325Ergonomic flat pillar stand, including incident and transmitted 3 W LED illumination, Universal single-arm stand for free observation of (large) objects. Mounted on a heavy base for maximum stability. Supplied without illumination. However, a wide 100-240 V power supply, both illumination intensities can be adjusted separately. sustaining Goosenecks and one transmitted 3 W LED illumination. Built-in 100-240 V power supply. Maximum object height 148 mm.Including 76 mm head holderNZ.9018NexiusZoom standsThe NexiusZoom stereo microscopes are supplied with a large choice of objectives and stands. Long working distances enable working comfortably under the microscope. Ideal for education, laboratories and industryThe NexiusZoom stands can be combined with both NexiusZoom and NexiusZoom EVO binocular and trinocular heads. Choose your system from the pre-combined sets or combine a microscope head with the stand of your choice10 6879121311Universal double-arm stand for free observation of (large) objects.Mounted on a heavy base formaximum stability. Guided double arm that allows titling of the head. Suppliedwithout illumination. However, a wide range of illumination systems is available.Maximum object height 213 mm. NZ.9090 or NZ.9095 head holderAP stand8Articulated stand for free observation of (large) objects. For working comfortablyunder the microscope. Mounted on a heavy base for maximum stability. Flexiblejointed arm for maximum flexibility. Supplied without illumination. However, a widerange of illumination systems is available. Maximum object height 185 mm.NZ.9081 head holderNZ.9027A stand9Identical to the AP stand but with a table-clamp mount.NZ.9081 head holderNZ.902510Large 320 x 285 mm pillar stand including adjustable transmitted 3 W LED illuminationand 76 mm head holder. Built-in 100-240 V power supply. Including 76 mm head holderLarge 320 x 285 mm pillar stand without illumination. Including 76mm head holder.With stone holding tweezers and built-in Iris. Comes with additional 1 W LED incident illumination. Built-in12NexiusZoom illuminationGood illumination of an object is crucial for stereo microscopy. When the correct illumination is chosen the details of the observed object becomes more distinct. Comfort and desired light intensity are the factors that determine the choiceSegmentation of LED’s (LE.1973)LE.5211 and LE.5211-LEDLE.5212 combined with a NZ.9000 stand and head (NZ.5902)NexiusZoomMechanical stages & positioning tablesStages can be an ideal toolfor stereo microscopes whendelicate positioning or heatingof a specimen is neededAE.5168-NZ 1Heating stage with X/Y mechanical stage.Temperature range: up to 50°C. LED display for settemperature (1 degree) and measured temperature(0.1 degree). For -S and -P stands*NZ.9505 2Mechanical 180 x 155 mm X-Y stage with 75 x 75 mmtranslation and transparent glass plate.For –S and –P stands*The stages are designed for -S and -P stands. Forother models, send your request* Supplied with new microscopes only21WD = working distance, OH = object height, FoV = Field of view, Total mag. = total magnificationNZ.8903 NZ.8904 NZ.8905 NZ.8907 NZ.8915 NZ.8920MODELSMax. frames (p/sec)Signal/Noise(db)Dynamic (db)Sensibility V/lux-secProduct numberCMEX-5 Pro143968.0 1.76DC.5000-PRO39100CMEX-10 Pro 835.563.50.31DC. 10000-PRO 25CMEX-18 Pro642651.3DC. 18000-PRO1832Digital Solutions for NexiusZoomCMEX 5, 10 & 18 PROThe Euromex digital solution products offer quick and accurate solutions for all industrial applications. Systems for computer and/or stand-alone use are available, all with calibrated measurement functions Check product quality, save images or videos, generate reports with great ease, high speed and accuracy This is a selection of the most popular cameras in the fieldDetailed information and all models are available The CMEX-5 Pro, -10 Pro and -18 Pro cameras are equipped with a 5.1, 10 or 18 MP CMOS sensor with 12 bits grayscale conversion and a 24 bits color rendering. These cameras are equipped with a USB-3 data interface enabling fast frame rate and are supplied with ImageFocus Alpha softwareHD CAMERASThe cameras are equipped with high sensitive sensors for low and intense light conditions and are UHD-4K Lite VC.30423840 x 2160 3840 x 2160 MP40.04 ~ 1000 ms3D algorithmcross/multicaptured & liveDigital SolutionsVC.3034, 3036, 3039 & 3042The Euromex HD cameras offer the perfect solution to modern microscopy where real-time images are needed. There is no longer a need for use of acomputer, because the software is built into the camera and the image can be displayed on any HDMI screen. Save high resolution images and calibrated measurements directly from the camera onto the integrated SD cardVC.3042dditional 0.3x lens. Working distance 287 mm. Only suitable fordditional 0.4x lens. Working distance 220 mm. Only suitable for NZ.9095NZ.9040NZ.9520AE.1112NZ.9572A B365 nm6500 KC D395 nm420 nmFor your own safety it is highly recommended to wearprotective orange glasses when using the 365 nm gooseneckEUROMEX MICROSCOPEN BV is a leading manufacturer of microscopes and other optical instruments. Founded in 1966, Euromex has become a world-class supplier of biological and stereo microscopesThe corporate office is based in Arnhem, The Netherlands. A facility with a 2.000 m2 conditioned logistics warehouse, an opto-mechanical workshop, an R&D department and a high-level quality control departmentAround the world, Euromex operates in more than 80 countries through distributors,resellers and agents. A wide variety of customers such as schools and educational institutes, clinical and research laboratories and a broad range of industrial customersare using Euromex microscopesISO 9001 The Euromex Quality System is certified according to ISO 9001:2015 and supports our pursuit of continuous improvement and our on-going commitment to provide our world-wide customers assurance of product qualityISO 13485 is the medical device industry’s most widely used international standard for quality management. Issued by the International Organization for Standardization (ISO), the ISO 13485 standard is an effective solution to meet the comprehensive requirements for a quality management system in the medical device industryv.224271G L O B A L H E A D Q UA R T E R SEuromex Microscopen bvPapenkamp 20 6836 BD Arnhem The NetherlandsTel: +31 (0) 26 323 22 11****************E U R O P E A N S A L E S OF F I C EEuromex Microscopen Spain sl Carretera de Barcelona 88, Entresuelo Esc. B - Local 908302 Mataró, Spain Tel: +34 (0) 937 415 609****************DISCLAIMERAll information and materials contained on this website have been prepared solely for the purpose of providing general information about the products offered by Euromex Microscopen bv. The content of and all information published on this website are provided in good faith as a convenience to you and may be used for information purposes only and at all times in accordance with these terms of accessEuromex Microscopen bv does not warrant the completeness or accuracy of information obtained from its website and does not undertake to update or correct its content or the information and/or materials contained on it on a regular basisEuromex Microscopen bv reserves the right to make improvements and/or changes to(including the removal of) the products described or referred to on the website and to delete and/or move any such information at any time and without notice ___Euromex is a registered trademark of Euromex Microscopen bv。
LC-SMS-2C LC-SMS-3B 体视显微镜使用说明书

LC-SMS-2C LC-SMS-3B体视显微镜使用说明书上海力辰邦西仪器科技有限公司SHANGHAI LICHEN-BX INSTRUMENT TECHONOLOGY CO.,Ltd前言使用前请仔细阅读产品使用手册,谢谢您的支持!妥善保存此使用手册,包含产品功能和操作详细说明,开箱检查仪器和相关配件,若发现异常及时与供应商或厂家联系。
一、应用领域广泛用于电子工业,精密仪器仪表的组装与检验,教育实验,观察与研究。
它可用于学校,研究所,工厂和家庭,以研究物体的地质,外观。
二、电指数输入电压:220V/50Hz或110V/60Hz(可选)三、照明控制1、自然采光。
2、入射光12V/10W(不带透射照明器)3、卤素灯12V/10W(不带透射照明器)4、入射和透射照明器12V/10W5、入射和透射卤素灯12V/10W以上5种样式是可选的四、结构指数垂直双眼头,倾斜45°双眼头是可选的。
屈光度调节+/-5°,瞳孔间距可调节54-76mm。
目镜调焦手轮目镜支柱直角棱镜组锁紧手轮底座物镜压片簧工作台板目镜视度调节圈物镜工作台板压片簧底座支柱调焦手轮目镜LC-SMS-2C 结构如图所示:LC-SMS-3B 结构如图所示:五、技术指示型号LC-SMS-2C LC-SMS-3B观察头双目直筒双目45º斜筒,瞳距55mm-75mm目镜WF10X WF10X物镜4X2X4X调焦系统粗调范围40mm粗调范围40mm 工作距离工作距离60mm工作距离57mm载物台Φ60黑白台板带切片压片Φ60mm磨砂玻璃/黑白版照明自然光上光源,12V/10W卤素灯产品单机尺寸16.5×11×27cm22×11.5×26cm六、如何使用1、环境要求:干燥无尘室温在-5-+40摄氏度之间。
2、照明控制:将电源线插入插座。
有关照明方式,请参阅下表。
对于带有调光器控制的显微镜,可以调节照明器的亮度。
生物微观镜产品数据表说明书

ED models with rechargeable batteries and integrated power supplyBB.4240 Binocular head Digital monocular head Digital binocular head Discussion headNOS E P I E C EReversed quadruple nosepiece on ball bearings. Models for polarization are supplied with a swing-out analyzerOBJ E C TI V E S• S upplied with semi plan 4x/0.10, 10x/0.25, S40x/0.65, S60x/0.85, S100x/1.25 oil immersion objectives configuration is depending on model• T he S40x, S60x and S100x oil immersion objectives are spring loaded (to prevent damage to sample and objectives)All optics are anti-fungus treated and anti-reflection coated for maximum light throughputF OCUS S I NG• C oaxial coarse and fine adjustments with 200 graduations. Precision 2 μm per graduation, 0.4 mm per rotation• T otal travel approximately 23 mm.• S upplied with an adjustable rack stop to prevent damage to sample and objectives• The coarse adjustment is equipped with friction controlSTAGE• 130 x 130 mm with mechanical 70 x 28 mm X-Y translation stage except for models BB.4200 and BB.4205• T hese models have a 120 x 120 mm plain stage supplied with twonon-removable object clamps• T he models for polarization are supplied with 129 mmround stage,360° rotatable and two object clampsP OL A RI Z AT I O N M O DE LS• Equipped with analyzer, mounted in a slider under the head• 360° Rotatable, graduated polarizer on the lamp house• S tandard supplied with a 20 W halogen illumination for correct color rendering and an integrated 100-240 Vac power supply• Polarisation attachments for standard microscopes are available optionallyCON D E N S E RHeight adjustable Abbe condenser N.A. 1.25 with iris diaphragmand filter holder I LLUM I N AT I O N LED• B inocular and trinocular models are supplied with an intensity adjustable 1 W NeoLED™ illumination system for increased light output • Monocular models are supplied with an adjustable 1W LED illumination • T he models for polarization are supplied with H-LED illumination for correct color rendering (very similar to the halogen light spectrum) and an integrated 100-240 V power supply. However 20 W halogen illumination is also available for polarization models on special request• A ll BioBlue microscopes – except halogen models – are supplied with rechargeable batteries and integrated power supply for cordless operationPAC K AG E CO N T E N T• S upplied with power cord, dust cover, a spare fuse, user manual and 5 ml immersion oil for models with S100x objective• M odels with halogen illumination are supplied with a blue filter and spare bulb, models with LED illumination are supplied with a white filter, all polarisation models are supplied with a cross hair eyepiece for centering • All packed in a polystyrene boxPolarization model BB.4260-PBB.4225(1) EVO models are supplied with WF 10x/20 mm eyepieces and Köhler NeoLED (tm) illumination(2)P olarization models are supplied with H-LED illumination - very similar light spectrum to the halogen illumination - and an eyepiece with crosshairs for centering. 20 W halogen illumination is also available for polarization models on special requestMOD EL SMono Bino Trino Digital4/10/40x SMP objectives S60x SMP objective S100x SMP objective Mechanical X-Y stageLED NeoLED™Köhler illumination (1)Polarization (2)BB.4200•••BB.4220••••BB.4240•••••BB.4250•••••BB.4260•••••BB.4260-E ••••••BB.4263•••••BB.4243•••••BB.4253•••••BB.4253-E ••••••BB.4205••••BB.4225•••••BB.4245••••••BB.4255••••••BB.4267••••••BB.4269••••••BB.4220-P-LED ••••BB.4240-P-LED •••••BB.4261-P-LED ••••BB.4263-P-LED •••••BB.4260-P-LED •••••BB.4241-P-LED ••••BB.4243-P-LED •••••BB.4253-P-LED•••••DIGI TAL MODEL SC A M E R A• A ll the BioBlue digital microscopes are equipped with a 5.0 MP CMOS USB-2 camera• M aximum resolution 2560 x 1920, 24 bits color depth, up to 30 frames per second• D elivered with ImageFocus Plus software, USB-2 cable and a micrometer 1mm/100 slide.• Warranty for the camera is 2 yearsS O F T WA R E• T he ImageFocus Plus software allows to save images in .jpg, .tif, .bmp or .dicom formats as well as .avi format videos.• I mages can be annotated and measurements can be performed in live or captured images• Compatible with Windows 7, 8 and 10, both 32 and 64 bits configurations • Mac OS version is also available• Updates can be downloaded on our website ACCESS ORIES AND SPARE PARTS E Y E P I E C E SAE.5571 Wide field eyepiece WF 5x/18 mmAE.5572 Wide field eyepiece WF10x/18 mmAE.5572-E Wide field eyepiece WF 10x/20 mmAE.5573 Wide field eyepiece WF15x/12 mmAE.5573-E Wide field eyepiece WF 15x/12 mm for BB EVOAE.5574 Wide field micrometer eyepiece 10mm/100AE.5581 Wide field eyepiece WF10x/18 mm with pointerAE.5581-E W ide field eyepiece WF 10x/20 mm with pointer for BB EVO AE.5582 Wide field eyepiece WF20x/11.5 mmAE.5582-E Wide field eyepiece WF 20x/12.5 mm for BB EVOAE.5365 Eyecup for 28 mm eyepiecesAE.5365-E Pair of eyecups for eyepieces for BB EVOO B J E C T I V E SAE.5591 Semi plan objective 4x/0.10. Working distance 37.5 mm AE.5593 Semi plan objective 10x/0.25. Working distance 6.54 mm AE.5594 Semi plan objective 20x/0.40. Working distance 1.2 mm AE.5597 Semi plan objective S40x/0.65. Working distance 0.68 mm AE.5599 Semi plan objective S60x/0.75. Working distance 0.2 mm AE.5601 S emi plan objective S100x/1.25 oil immersion.Working distance 0.22 mmM I S C E L L A N E O USAE.1110 Stage micrometer 1 mm/ 100 partsAE.5511 Discussion headAE.5202 Blue filter, diameter 32 mmAE.5203 Yellow filter, diameter 32 mmAE.5204 Neutral grey filter, diameter 32 mmAE.5205 Green filter, diameter 32 mmAE.5207 Blue filter plexiglass, diameter 32 mmBB.4300 Aluminium case for BioBlue microscopesAE.9918 Nylon microscope bag (25 x 39 x 19 cm)BB.9602 Analyzer in sliderAE.9981 1 W LED replacement unitAE.9991 1 W NeoLED™ replacement unitSL.1379 S pare halogen 20 W 12 V bulb for BioBluepolarization modelsAE.5227 Glass fuses 1 A 250 V, 10 piecesC A M E R A ACC E S S O R I E SAE.5130 U niversal SLR camera adapter with 2x projectionlens for 23.2 mm tubes. Need T2 adapterAE.5025 T2 adapter for Nikon D digital SLR camerasAE.5040 T2 adapter for Canon EOS digital SLR camerasOther T2 adapters on requestD I S P O S A B LE SPB.5155 Microscope slides 76 x 26 mm, ground edges, 50 pieces PB.5165 Cover glasses 18 x 18 mm, thickness 0.13-0.17 mm, 100 pieces PB.5168 Cover glasses 22 x 22 mm, thickness 0.13-0.17 mm, 100 pieces PB.5245 Lens cleaning paper, 100 sheets per packPB.5255 Immersion oil, n = 1.482 (25 ml)PB.5274 Isopropyl alcohol 99% (200 ml)PB.5275 C leaning kit: lens cleaning fluid, lint free lens tissue, brush, air blower, cotton swabsAE.9918EuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•F+31(0)263232833•****************•AE.5151AE.5154 AE.5155-PAE.5150AE.5152AE.5156AE.5158-PP O L A R I Z AT I O N AT TAC H M E N T SNot suitable for the BioBlue EVO modelsAE.5150 S imple polarization attachment. Polarizer 18 mm diametermounted in eyepiece, analyzer 32 mm diameter placed in filter holderAE.5151 S imple polarization attachment. Polarizer mounted overeyepiece and analyzer 32 mm diameter in filter holderAE.5152 S imple polarization attachment. Polarizer mounted overeyepiece and analyzer 32 mm diameter in filter holderAE.5153 S imple polarization attachment. Analyzer mounted overeyepiece and 360° rotatable polarizer on tableAE.5154 Polarizer in mount, to place over eyepieceAE.5155 P olarization attachment with analyzer and slider, rotatable stagefor X-Y mechanical stage and polarizer on lamp houseAE.5155-P P olarization attachment with analyzer and slider, rotatable stagefor stage with clamps and polarizer on lamp houseAE.5156 P olarization attachment with analyzer and slider,and polarizer on lamp houseAE.5158 P olarization kit with analyzer in slider and small rotatable(75 x 50 mm) stage with two clamps to be mounted on X-Y stage. Rotatable 360° polarization filter to be mounted on lamphouseAE.5158-P P olarization kit with analyzer in slider and small rotatable (100x 65 mm) stage with two clamps to be mounted on plain stage. 360° Rotatable polarization filter to be mounted on lamphouseB ioBlue with polarization kit。
锐视科技 NexiusZoom 和 NexiusZoom EVO 微观显微镜说明书

• NZ.5302 / NZ.5303•NZ.1902-AP•NZ.9505450360º| L E S S C I E N C E S D E S M A T ÉR I A U X || S C I E N C E S D E L A V I E || E N S E I G N E M E N T |S TAT I F• S tatifs de conception ergonomique à colonne ou à crémaillère avec éclairage à LED de 3W incident et transmis. (statifs -P et -S)• S tatif de conception ergonomique à colonne avec éclairage incident par deux fibres en col de cygne de chaque côté du statif, chacune équipée d’un LED de 3W, puis éclairage transmis à LED de 3W (statif -PG)• S tatif ergonomique à colonne avec miroir rotatif et éclairage incident et transmis à LED de 3 W ( statif -M)• S tatifs universel ou statif lourd à double bras déporté, sans éclairage (Statif -U, -B et BC)• S tatif à bras articulé pour le montage sur une table ou avec une base lourde, les deux livré sans support de tête et sans éclairage (Statifs -A et -AP)Tous les statifs à colonne et à crémaillère sont livrés avec des valets de fixation. Alliage métallique et revêtement trempé en couleur blanc-casséP L AT I N EPlatine mécanique de 180 x 155mm avec mouvements X-Y de 76 x 55mm et disque porte objet en verre transparent pour NexiusZoom, fixée sur la platine du microscope. Seulement valable avec microscopes neufs (car montage en usine), il doit donc être commandé avec le microscope (voir photo : NZ.9505)ÉC L A I R AG EÉclairage transmis et incident par LED de 3 W avec alimentation Interne de 100-240 V. Les deux éclairages peuvent être utilisés simultanément et lesintensités lumineuses peuvent être réglées séparément. Les statifs universels simple ou double et les statifs à bras articulés peuvent être équipés des éclairages annulaires LE.1974 et LE.1973 avec respectivement 72 ou 144 LEDs puissantes segmentées, idéal pour créer ou accentuer des ombresM Pour les applications d’inspection et de montage. La décharge électrostatique (ESD) est le flux d’électricité indésirable entre deux objets électriquement chargés. Les décharges électrostatiques peuvent causer des effets nocifs ainsi que des dommages permanents sur composants électroniques semi-conducteurs.Euromex présente des microscopes protégés électro statiquement dans la gamme NexiusZoom. Le corps et le support du microscope sont revêtus d’une peinture antistatique spéciale éliminant les décharges électrostatiques nocives, rendant ainsi les microscopes adaptés pour tous les environnements sensibles à l’électricité statique25639346339103180178220259.5310.5| L E S S C I E N C E S D E S M A T ÉR I A U X | | S C I E N C E S D E L A V I E |F I C H E T E C H N I Q U E| E N S E I G N E M E N T |N E X I U S Z O O M E V O 0.65-5.5 (W F 10X /23M M)N E X I U S Z O O M 0.67- 4.5 (W F 10X /22M M)MO D ÈL E SBinoTrinoStatif à colonne (-P)Statif à crémaillère (-S)Statif universel (-U)Statif à double bras déporté avec base lourde (-B)Statif à double bras déporté avec pince de table (-BC)Statif à bras articulé avec pince de table (-A)Statif à bras articulé avec base lourde (-AP)Statif avec double fibre à LED (-PG)Miroir LED (-M)Poids(kg)NZ.1902-P •• 5.0NZ.1902-PG •••5.1NZ.1902-M •••4.9NZ.1902-S ••4.9NZ.1902-U ••15.6NZ.1902-B ••22.1NZ.1902-BC ••10.5NZ.1902-A ••8.6NZ.1902-AP ••20.7NZ.1903-P •• 5.2NZ.1903-PG •••5.3NZ.1903-M •••5.1NZ.1903-S ••5.1NZ.1903-U ••15.7NZ.1903-B ••22.2NZ.1903-BC ••10.6NZ.1903-A ••8.7NZ.1903-AP••20.8MO D ÈL E SBinoTrinoStatif à colonne (-P)Statif à crémaillère (-S)Statif universel (-U)Statif à double bras déporté avec base lourde (-B)Statif à double bras déporté avec pince de table (-BC)Statif à bras articulé avec pince de table (-A)Statif à bras articulé avec base lourde (-AP) Statif avec double fibre à LED (-PG)Miroir LED (-M)Poids (kg)NZ.1702-P •• 5.0NZ.1702-PG •••5.1NZ.1702-M •••4.9NZ.1702-S ••4.9NZ.1702-U ••15.6NZ.1702-B ••22.1NZ.1702-BC ••10.5NZ.1702-A ••8.6NZ.1702-AP ••20.7NZ.1703-P •• 5.2NZ.1703-PG •••5.3NZ.1703-M •••5.1NZ.1703-S ••5.1NZ.1703-U ••15.7NZ.1703-B ••22.2NZ.1703-BC ••10.6NZ.1703-A ••8.7NZ.1703-AP••20.8D I ME N S I O N SLes modèles NexiusZoom Evo sont désormais équipés de click-stopsNZ.8903 NZ.8904 NZ.8905 NZ.8907 NZ.8915 NZ.8920 TA B L E AU D E M PAT I B I L I TÉD L E N T I L L E S A D D O N N E L L E SM O DÈL E S Grossiment 0,3x Grossiment 0,4x Grossiment 0,5x Grossiment 0,75x Grossiment 1,5x Grossiment 2x NZ.9000/9005•••NexiusZoom-P, -M, -PG•••NexiusZoom-P-ESD•••NexiusZoom-S•NexiusZoom-S-ESD•••NZ.1903-B•NZ.1902-BC•NZ.1903-S•NZ.1902-M•NZ.1902-PG•NZ.1902-P•NZ.1902-U• NZ.1903-U-ESD• NZ.1903-B-ESD• NZ.1903-P-ESD• NZ.1903-S-ESD• NZ.9095 L E N T I L L E S A D D I• NZ.9005• NZ.9000Le LE.5212 sous deux configurations différentes EuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•****************•。
OXION 荧光显微镜产品说明书

Plan, plan Fluarex and plan semi apochromatic Fluarex IOS objectivesluorescence attachment for maximum four filter blocks and withOX.3085OX.3085 454 (h) x 276 (w) x 578 mm (d) | 12.2 kgOX.3230| L I F E S C I E N C E |ACC E SS O R I E S A N D SPA R E PA R T SE Y E P I E C E SAE.3210 HWF 10x/22 mm eyepiece AE.3215 HWF 15x/13 mm eyepiece AE.3223 H WF 10x/22 mm eyepiece with10 mm/100 micrometerAE.3225 Pair of eyecupsO B J E C TI V E SAE.3102 Plan 2x/0.06 IOS objective. WD 5 mm AE.3104 Plan 4x/0.10 IOS objective. WD 11.9 mm AE.3106 Plan 10x/0.25 IOS objective. WD 12.1 mm AE.3108 Plan 20x/0.40 IOS objective. WD 1.5 mm AE.3110 Plan S40x/0.65 IOS objective. WD 0.36 mm AE.3112 Plan S60x/0.85 IOS objective. WD 0.30 mm AE.3114 Plan S100x/1.25 oil IOS objective. WD 0.18 mm 86.550 Plan Fluarex 4x /0.15 IOS objective. WD 21.6 mm 86.552 Plan Fluarex 10x/0.35 IOS objective. WD 2.9 mm 86.554 Plan Fluarex 20x/0.60 IOS objective. WD 1.5 mm 86.556 P lan Fluarex S40x/0.75 infinity corrected IOS objective.WD 0.6 mmIS.7400 P lan Fluarex PLFi S100x/1,30 IOS infinity corrected objective.0.17 mm cover glass correction. WD 0.13 mmAE.3144 P lan semi apochromatic Fluarex 4x/0.13IOS objective. WD 18.5 mmAE.3146 P lan semi apochromatic Fluarex 10x/0.30IOS objective. WD 10.6 mmAE.3148 P lan semi apochromatic Fluarex 20x/0.50IOS objective. WD 2.33 mmAE.3152 P lan semi apochromatic Fluarex S40x/0.75IOS objective. WD 0.6 mmAE.3156 P lan semi apochromatic Fluarex S100x/1.28 oilimmersion IOS objective. WD 0.21 mmMOD EL SBino TrinoPlan 4x/10x/S40x/S100x objectives Plan Fluarex 4x/10x/S40x/S100x objectives Plan semi apo Fluarex 4x/10x/S40x/objectives Plan semi apo fluarex S100x objectives 100 W mercury vapor illumination 455 nm FluoLED illuminationOX.3067•••OX.3070•••OX.3075•••OX.3080••••OX.3085••••OX.3230•••OX.3235•••OX.3232••••OX.3237••••F L U O R E S C E N C E F I LT E R S E T SAE.3245 F luorescence block with general purpose filter set for blueexcitation (EX 465-495 nm DM 505 nm EM 515-558 nm). Excellent for FITC, eGFP. Compatible for 5-carboxyfluorescein (5-FAM), Alexa fluor 488, BODIP-FL, Calcein, Cy2, eGFP, FITC, Fluo-4, Fluor-Jade, FluorX, Mito tracker Green, Rhodamine 110, Spectrumgreen 110AE.3246 F luorescence block with general purpose filter set for greenexcitation (EX 540-580 nm DM 600 nm EM 605-665 nm). Excellent for Texas Red, Alexa 594, 5-Carboxynaphthofluorescein. Other compatible fluorophores: 5-CNF, 5-ROX (carboxy-X-rhodamine),Alexa Fluor 568, Alexa Fluor 594, Cy3.5, Lissamine rhodamine B, Mito Tracker Red, mPlum mRaspberry, Rhodamine Red, SpectrumRed, Texas Red, X-Rhodaline (XRITC)AE.3247 F luorescence block with general purpose filter set for violetexcitation (EX 410-440 nm DM 455 nm EM 465 nm LP). Compatible fluorophores: Cerulean, CFP, SpectrumAquaAE.3248 F luorescence block with general purpose filter set for UVexcitation (UV EX 361-389 nm DM 415 nm EM 435-485 nm). Compatible fluorophores: 7-amino-4methylcoumarin, 7-Hydrixy-4-methylcoumarin (pH9), Alexa Fluor 350, AMCA, AMCA-X, Calcein Blue, Calcein White, Cascade Blue, DAPI, Hoechst 33342 & 33258, LysoSensor Blue (pH5), Lyso Tracker Red, marina Blue, Spectrum BlueAE.3249 E mpty filter cube for modelsOX.3066/OX.3067/OX.3070/3075/3080/3085Euromex Microscopen bv • Papenkamp 20 • 6836 BD Arnhem • The Netherlands • T +31 (0) 26 323 22 11 • info@ • | L I F E S C I E N C E |P O L A R I Z AT I O N AT TAC H M E N T SAE.3190 Polarizer/analyzer set AE.3192 Polarizer slider for nosepiece AE.3194 Polarizer for lamphouseF I LTE R SAE.3196 F rosted white filter 45 mm, to be mounted on lamphouse AE.3198 B lue filter 45 mm, to be mounted on lamphouse AE.3200 Y ellow filter 45 mm, to be mounted on lamphouse AE.3202 G reen filter 45 mm, to be mounted on lamphouseC A M E R A ACC E S S O R I E SAE.5120-2 S tandard 23.2 mm diameter tube for Oxion photo portrevision-2AE.5130 U niversal SLR camera adapter with 2x projection lens for 23.2 mmtubes. Needs T2 adapter and AE.5120AE.5025 T2 adapter for Nikon D digital SLR cameras AE.5040 T2 adapter for Canon EOS digital SLR camerasOX.9850 C S/C mount with 0.5x objective for 1/2” sensor cameras OX.9833 C S/C mount with 0.33x objective for 1/3” sensor camerasM I S C E L L A N E O U SAE.5168-O H eating stage and temperature controller upto 50°C. Only with new microscopesSL.1385 100 W HBO mercury vapor lamp for fluorescence SL.5510 NeoLED™ replacement unit for OxionAE.3199 Glass fuses 3.15 A 250 V, 10 piecesD I S P O S A B LE SPB.5155 M icroscope slides 76 x 26 mm, ground edges, 50 pcsPB.5165 C over glasses 18 x 18 mm, thickness 0.13-0.17 mm, 100 pieces PB.5168 C over glasses 22 x 22 mm, thickness 0.13-0.17 mm, 100 pcs PB.5245 L ens cleaning paper, 100 sheets per pack PB.5255 I mmersion oil, n = 1.482 (25 ml) PB.5274 I sopropyl alcohol 99% (200 ml)PB.5275 C leaning kit: lens cleaning fluid, lint free lens tissue, brush, airblower, cotton swabs。
英国工业显微镜Lynx VS8 PCB专用显微镜说明书

浏览我们多国语言的网站:
LYNVS8_cn23/0808
技术参数
光学
高能光学无焦-体视变焦-无目镜的显微镜提供2 6 .4 度的 可视景角。 高能光学专利技术确保使用者头部活动达到1 0 毫米径向 和7 0 毫米轴向的自由度,优化了头部和身体姿势的舒适。
变焦放大倍率(参阅表格)
7倍 - 40倍 变焦比5 . 7 : 1
照明装置
1 4 个可调节明暗的发光二极管(LED)环形灯
专利的体视无目镜光学为提高缺陷检定,提供一流的成像分辨 率和对比度。 便捷的眼手配合减少操作员的疲劳,由此而来提高了效益和 精确度,同时降低了次品率。 可切换的直接或倾斜、旋转观测能对焊点、孔深、柱体、以及 螺文线进行详细的检测。
Lynx VS8专利的无目镜光学技术提供专门PCB印刷电路板检测。
扫描平台
倾斜观测 视野
在最大焦距
在最小焦距 (连续的)
5.0毫米
16.0毫米
740毫米 (902毫米,选配*)
* 特大世界各地拥有一个专业的代理分销网络。有关详情,请联系你所在地的英国Vision分机构、授权的 代理分销商、或浏览我们的网站。
Vision Engineering Ltd. (Manufacturing) Send Road, Send, Woking, Surrey, GU23 7ER, England Tel: +44 (0) 1483 248300 Fax: +44 (0) 1483 223297 Email: generalinfo@
代理分销商
Vision Engineering Ltd. (France) 1 Rue de Terre Neuve, ZA Courtaboeuf, 91967 Les Ulis Cedex, France Tel: +33 (0) 164 46 90 82 Fax: +33 (0) 164 46 31 54 Email: info@visioneng.fr
ZEISS EVO 扫描显微鉴定仪 3说明书

Scanning Electron MicroscopeIn an industrial quality, failure analysis, or research environment, the scanning electron microscope is the solution of choice for metallography and failure analysis applications, due to its ability to provide both high resolution imaging and high spatial resolution elemental chemistry.Designed specifically for routine inspection and analysis applications, ZEISS EVO excels at offering an operational concept that appeals not only to experienced microscopists, but also to engineers who are not SEM experts. It delivers best-in-class, high quality data, especially for non-conductive parts that cannot be coated with a conductive layer due to a requirement for subsequent inspection.A truly unique attribute of EVO is its seamless integration into a multi-modal QA or FA workflow, thanks to features like semi-automated relocation of regions of interest and data integrity solutions – across systems, labs or even locations.EVO is also the platform for certain turn-key industrial solutions for cleanliness as well as mineral analysis and processing.With a wide choice of chamber sizes, vacuum system, electron emitter types, and analytical options, the odds are good that your EVO can be matched closely to your price-performance requirements.Industry has a New Ally.Count on ZEISS EVO as the best qualified SEM to support industrial QA and FA labs.High Resolution Surface MorphologySecondary electron (SE) imaging – with a maximum resolution of a couple of nanometers – comfortably covers most of the sub-micron length-scale. While light microscopy yields contrast (reflections) from surfaces, secondary electron emission yields contrast from edges on the sample surface, thereby providing greater detail of surfacemorphology, such as that of metal fractures.High Spatial Resolution Elemental AnalysisIn Energy Dispersive Spectroscopy (EDS), X-rays generated by the interaction of the finely focused electron beam with the part yields the elemental composition of the surface. Applying a scanning beam yields the distribution of chemical elements across the region of interest. EVO with EDS offers a great solution for visualizing the possiblecontribution of elemental chemistry to quality challenges or material failures.Take Your Investigation to the Next Level.EVO takes over when you’ve reached the resolution or contrast limit of light microscopy, but still need answers.Compositional ImagingBackscattered electron (BSE) imaging yields contrast that is directly proportional to the density of the materials that constitute your parts or assemblies. It provides a snapshot of compositional heterogeneity that can help you determine the root cause of material failure or quality excursions.Stainless steel fracture surface, with strong contrast from the fracture surface edges likely delineating metal grains. Horizontal field of view: 10 μm.Backscattered electron image of dissimilar joint of low alloy steel (8630) with nickel alloy (625) weld metal, revealing complex compositional heterogeneities across the joint. Horizontal field of view: 100 μm. Sample courtesy: TWI Ltd.Elemental map across the dissimilar joint shown above, revealing the spatial distribution of MolybdenumElectron SourceChoose between the standard thermal electron emitter (tungsten hairpin), or treat yourself to a lanthanum hexaboride (LaB 6) thermal emitter and benefit from up to 10 times more electron beam brightness. ZEISS has continuously improved the implementation of LaB 6 in SEMs over decades, resulting in enhanced ease- of-use and better image quality, especially when using VP mode.The Environment to Match Your SamplesChoose between the standard (high) vacuum configuration for metallic andother conductive parts, or add the optional Variable Pressure (VP) mode for imaging and analysis of non-conductive parts, without coating or preparation that might interfere with your multi-modal QA or FA analysis workflow. When choosing VP, be sure to also select the best-in-class secondary electron detector, the ZEISS C2D, for surface morphology imaging of non-conductive parts.Powerful Yet AffordableThe perfect match to your price–performance requirementsAnalytical Capabilities that Extend EVO’s UtilityOptionally, configure your EVO with particle analysis capabilities, enablingyou to greatly enhance productivity through overnight runs of filters from your colleagues’ cleanliness analysis workflows.Chamber SizeChoose from three vacuum chamber sizes (EVO models 10, 15 and 25) to select the one that best fits your imaging and analysis requirements, whether you work with smallcomponents, or very large parts or assemblies, such as powertrain or electrical components.Backscattered electron image of a tyre cord, showing the steel wire (bright) intermixed with rubber (dark). Horizontal field of view: 2 mm.Secondary electron image of a lanthanum hexaboride electron emitterBackscattered electron image of particles on a filter. Horizontal field of view: 4 mm1 µmThe ZEISS EVO product family caters to a wide range of configuration options:“New SmartSEMTouch is so easyto learn, ourintern Laurenis up to speedin 20 minutes!Thanks”@ZEISS_Group,@zeiss_microECR EnginesGet More Hands on Deck.SEM operation for both expert and novice usersIn industrial material laboratories, throughput and time todata suddenly becomes critical when quality excursions inmanufacturing are discovered, or failed parts are returned fromthe field. As resources are deployed to get answers, it is goodto know that the EVO SEM can be operated by both expert andnon-expert electron microscopists by means of the dedicated,simplified graphical user interface.SEM Operation forExperienced UsersBy default, the EVO is operated from aWindows 10 graphical user interface,ZEISS SmartSEM, which features all thefunctionality required by the expertuser. Additionally, a control panel isavailable providing convenient shortcutsto the most common functions, such asmagnification, focus and stigmation, orcontrast and brightness.SEM Operation forNon-MicroscopistsFor novice and occasional users,EVO also can be operated from thesimplified graphical user interfaceSmartSEM Touch, by mouse or touchcontrol. This interface allows pre-programming of instrument settings forrepetitive imaging of parts commonlyoccuring in a quality inspection orfailure analysis environment.SmartSEM Touch: interface for novice users ECR Engines is a high-performance engineproduction and development company that hasearned over 250 victories in NASCAR racing series.The company extracts the maximum performancefrom conventional V8 engines by relentlesslyengineering parts to find every possible bit ofincremental improvement and through systematicquality inspection of all failure prone parts. Overthe last few years, ECR Engines has replacedtheir equipment from other vendors and is nowoperating exclusively with ZEISS instruments. SmartSEM: interface for experienced usersUnderstandably, there may be reluctance to move a particular part to SEM. Non-conductive surfaces will charge under the electron beam. While a range of sample preparation solutions exist to mitigate this challenge, parts that will continue through a multi-modal QA or FA workflow must remain unaltered.EVO excels at extracting the maximum data quality from uncoated and unaltered parts. EVO’s variable pressure operation suppresses surface charge by a process of gas ionization in the vacuum chamber. Dedicated variable pressure detectors (in particular, EVO’s charge cascade detector, C2D) are optimized for secondary electron detection, at reduced beam acceleration voltages, and – if required – long working distances. And last but not least: the optional lanthanum hexaboride (LaB 6) emitter ensures the best possible noise-free images under these challenging conditions.Image as Presented.Analyze samples in their native state for the most accurate, best quality image and data.Image of impregnated woven fiber material, revealing the fibers and the filler material. Imaged at low kV with secondary electrons in variable pressure. Particularly at such challenging conditions, the benefits of LaB 6 become most apparent.In industrial quality assurance, as well as in failure analysis, a thorough assessment may require data acquired from other inspection or analysis modalities to get to the root of a problem.Plays Well with Others.Benefit from workflow automation and correlative microscopy with ZEISS EVO.This is where EVO excels, by “playing well with others”. The power of the multi-modal workflow, where a part moves from instrument to instrument, is in the acquisition of data complementary to SEM data, which provides an even broader perspective to the problem. The Shuttle & Find module of ZEISS image analysis and archive software, ZEN 2 core, allows EVO to be included in a multi-modal workflow with other ZEISS microscopes. Shuttle & Find and ZEN 2 core streamline sample exchanges and speed workflows with fast, semi-automated relocation of region of interests, automatic storage of data from multiple modalities in a single project folder, and overlay of imaging and elemental chemistry data from multiple modalities.Multimodal data acquisition is reality already for some, and near future for others in industrial QA and FA environments. In any case, EVO is ready for integration in correlative microscopy or analysis workflows. And for regulated industries such as pharmaceutical or aerospace, every EVO is GxP compliant through the GxP module in ZEN 2 core.Popular Multimodal Workflows are: • ZEISS stereo or digital light microscopes to EVO for enhanced part inspection and documentation • ZEISS (light) particle analyzers to EVO Correlative Particle Analysis (ZEISS CAPA)• EVO to ZEISS confocal microscopyfor tribology applicationsOverview image of the same sample, acquired at lower magnification in variable pressure mode with the C2D detector. Horizontal field of view: 1 mm.Value Beyond Routine SEM ApplicationsTurnkey solutions for industrial cleanliness and mineral processingCompliant with Industry Standards The current SmartPI solution was developed in collaboration with a major global automotive component supplier, which assures it meets the most current and demanding industrial cleanliness requirements, including the latest VDA 19 Part 1 and 2 cleanliness measurement standard.Cross-Frame Particle Detection One unique characteristic of SmartPI is the ability to detect cross-frame particles, ensuring the largest particles are not omitted from the measurement.Correlative Particle Analysis SmartPI on the EVO, working together with ZEISS light microscopy particle analyzers, enable a correlative workflow, whereby the light microscopes detect particle size, differentiate shape, and classify metallic particles, before EVO takes over to measure the elemental composition of the metallic particles. This highly efficient workflow not only finds particles, but also classifies particles by size, shape and likely contamination or wear origin.A second turnkey solution available for EVO is Mineralogic, an automated mineralogy solution for geosciences and the mineral processing industry. Request more information about Mineralogic from your ZEISSrepresentative.SmartPI is the ZEISS automated, standards-compliant SEM Particle Analysis solution that, in contrast to light microscopy-based cleanliness solutions, allows particle classification on the basis of elemental composition. SmartPI data helps engineers relate the cleanliness data to the source of particle contamination. SmartPI is implemented on EVO as a turnkey solution for industrial cleanliness, and is supported entirelyby ZEISS.Get more Answers.Connect with other solutions in the ZEISS QA portfolio.Optical Inspection and Documentation ZEISS Smartzoom 5Smartzoom 5 is the ZEISS digital light microscope for routine industrial QA inspection and documentation applications. Designed for imaging and measurement repeatability, enhanced depth of field, and automated intelligent illumination, it is the most popular companion to EVO in a multimodal QA inspection workflow.Surface and Roughness Analysis ZEISS Smartproof 5This digital confocal microscope delivers quantitative 3D imaging and roughness measurements for surface analysis investigations. Smartproof 5 is a turnkey and easy to use instrument that can be implemented with minimal training. Non-microscopist users can take advantage of guided workflows to produce fast, precise and repeatable results.Optical 2D Measurements ZEISS O-SELECTO-SELECT is the digital profile projector for 2D optical metrology applications. Equally turnkey and as easy to use as Smartzoom 5, O-SELECT makes 2D optical measurements available with the touch of a single button.3D X-ray Microscopy ZEISS XradiaXRM is the ZEISS non-destructive 3D imaging solution that performs X-ray computed tomography with imaging resolutions well below 1 micrometer. XRM is ideal for parts or assemblies that cannot be sectioned or dismantled for inspection of the internal materials and structures.Particle Analysis SolutionsFor advanced analysis of technical cleanliness, ZEISS has a range of light and electron microscope particle analysis solutions to cover a wide range of particle sizes and types. CAPA Correlative Particle Analyzer combines light and electron microscopy for particle classifications that require understanding of both morphology and elemental composition.ZEISS Industrial Metrology PortfolioIf you need to include additional capabilities to meet your QA requirements, check out the ZEISS IMT group’s dedicated industrial metrology solutions which include a range of sensor, infrared and X-ray based inspection and metrology solutions./metrologyYou Work Hard: We Make Sure Your Microscope Keeps Pace with You.High imaging quality, reliable results and instrument availability are the parameters of your day-to-day working life. Your ZEISS microscope integrates seamlessly into this demanding workflow. It provides you with insights and results that you can trust: thorough, comprehensive and reproducible. With ZEISS Life Cycle Management we help you to keep your microscope in optimum condition to get these optimum results. Life Cycle Management Comes with Your MicroscopeLife Cycle Management from ZEISS backs up our solutions throughout the working life of your ZEISS microscope system. From the procurement phase onward, you can count on our support, starting with site surveys to optimize the location for your microscope system. Throughout the operational phase we will complement our service with support for relocations and upgrade opportunities that enhance or expand your possibilities. As soon as you think about replacing your long-serving microscope with a new one, we will take care of the disassembly and disposal of systems that are no longer needed. Rely on our service features: our employees analyse the status of your system and solve problems via remote maintenance or directly at your location.From Expert to ExpertNever hesitate to ask our application specialists to support your specific tasks. And be sure to tap into our training sessions for any colleagues or employees who will be working with your ZEISS microscope.Peace of Mind and Availability with Regular MaintenanceYour service plan is tailor-made for you. Make sure you take advantage of all the oppor t unities your ZEISS microscope system offers. Get optimized performance, instrument r eliability and availability at predictable costs. Choose from different service levels of our Protect Service Plans, ranging from Protect preventive, via Protect advanced, to Protect premium. We look forward to discussing your ideal service plan personally.Service and Supportfor Your ZEISS Microscope System.ZEISS Moments are about passion. The same passion that drives us to support and accompany you andyour ZEISS microscope over its life cycle makes sure that yourwork will lead systematically to success.Carl Zeiss Microscopy GmbH 07745 Jena, Germany******************** /evo Notfortherapeutic,treatmentormedicaldiagnosticevidence.Notallproductsareavailableineverycountry.ContactyourlocalZEISSrepresentativeformoreinformation.EN_42_12_245|CZ1/17|Subjecttodesignchangesandchangestocontentsincludedindelivery,aswellastechnologicaladvancements.|©CarlZeissMicroscopyGmbH。
EVO18扫描电镜操作培训

• 关机 • 关闭软件 • 关闭电脑 • 按下黄色按钮 • 30秒后按下红色按钮
Optibeam®
分析模式 探针电流不断改变的情况下仍可聚焦试样 视场模式
大视场预览和大景深
分辨率模式 在任何的工作距离或电压下,保证探针 电流直径是最小的 景深模式 在任何的工作距离或电压下,选择的 探针电流确保具有最大的景深 鱼眼模式 大视场预览和大景深
3、电子束在样品中的散射。
分辨率取决 于电子束的散 射范围。 二次电子: 几nm; 背散射电子 和X射线:由几 百nm至几um。
俄歇电子 二次电子 背散射电子
阴极荧光
特征 X 光线
连续 X 光线 荧光 X 光线
电子束与样品的相互作用区域
2、衬度——影响衬度的因素:
1、表面形貌(倾 斜效应):
入射电子束 方向一定,试样表 面的凹凸决定电子 束入射角。 检测器固定 后,对试样表面各 区域产生的二次电 子收集角不同。
• 电子束斑大(也即探针电流大),景深大, 信号强,图像噪音小,但分辨率较低,样 品表面易充电。 • 电子束斑的大小取决于第一聚光镜的励磁 电流,电流数值越小,电子束斑直径越大。
工作距离的选择
工作距离(WD) 是指物镜下表面
与样品表面的距
离,WD短可以得 到较高的分辨率, WD长可以得到大 的倾斜角度和大
?打开氮气?在控制面板里点击真空vaccum标签?点放气vent?拉开舱门?把样品座安装在样品台上?关紧舱门?点击抽真空pump键?加灯丝电流?真空度达到要求后屏幕右下角的vac会打?灯丝电流加载完后gun也会打上绿钩?样品定位?选取stagenavigation?双击所要观测样品桩在tv模式下调整高度样品台目前所在的位置输入移动目的地的坐标输入移动的距离选择时样品台在泄真空时自动下降到最低点选择时sem显示的工作距离随样品台的z方向移动自动进行更改选择时不使用样品台控制器调整至所需要的放大倍数并聚焦清晰选择相应的探测器选择探头收集器偏压选择两种信号混合两种混合信号的比例调节图像的亮度调节图像对比度?图像调整的优化?点击reducedraster?在小框中进一步聚焦物镜光阑合轴?消象散?点击aperature下的stigmation拖动xy轴直至图像清晰选择endframe当扫描完毕后橙点变为红点图像静止
生物蓝宝石 EVO 生物显微镜产品说明书

MONOCULAR MODEL BB.4200 320 (h) x 176 (w) x 227 mm (d) | 3.0 kg BB.4260-Eeight adjustable Abbe condenser with iris diaphragm and filter holderE Supplied with semi plan 4x/0.10, 10x/0.25, S40x/0.65 and S100x/1.25 oilimmersion objectiveshe S40x and S100x oil immersion objectives are spring loaded (to preventdamage to sample and objectives)All optics are anti-fungus treated and anti-reflection coated for maximum lightN Goaxial coarse and fine adjustments with 200 graduationsPrecision 2 μm per graduation, 0.4 mm per rotationNeo LEDf.n. 18 mm f.n. 20 mmheight adjustment levercondenseraperture diaphragmfield Köhler diaphragmlight source NeoLED/halogenEuromexMicroscopenbv•Papenkamp20•6836BDArnhem•TheNetherlands•T+31(0)263232211•F+31(0)263232833•****************•AE.9918AE.5572-E EWF10x/20 mm eyepieceAE.5581-E EWF10x/20 mm micrometer eyepiece with pointer AE.5580-E EWF10x/20 mm micrometer eyepiece with crosshairAE.5579-E E WF10x/20 mm micrometer eyepiece with 10/100 micrometerand cross hairAE.5573-E WF15x/16 mm eyepiece AE.5582-E WF20x/12 mm eyepieceAE.1110 Stage micrometer 1 mm/ 100 partsAE.5591 Semi plan objective 4x/0.10. Working distance 37.5 mm AE.5593 Semi plan objective 10x/0.25. Working distance 6.54 mm AE.5594 Semi plan objective 20x/0.40. Working distance 1.2 mm AE.5597 Semi plan objective S40x/0.65. Working distance 0.68 mm AE.5599 Semi plan objective S60x/0.75. Working distance 0.2 mm AE.5601 S emi plan objective S100x/1.25 oil immersion.Working distance 0.22 mmAE.5202 Blue filter, diameter 32 mm AE.5203 Yellow filter, diameter 32 mm AE.5204 Neutral grey filter, diameter 32 mm AE.5205 Green filter, diameter 32 mm AE.5207 Blue filter plexiglass, diameter 32 mmAE.5130 U niversal SLR camera adapter with 2x projectionlens for 23.2 mm tubes. Need T2 adapterAE.5025 T2 adapter for Nikon D digital SLR cameras AE.5040 T2 adapter for Canon EOS digital SLR cameras Other T2 adapters on requestBB.4300 Aluminium case for BioBlue microscopes AE.9918 Nylon microscope bag (25 x 39 x 19 cm)BB.9602 Analyzer in sliderAE.9991 1 W NeoLED™ replacement unit AE.5227 Glass fuses 1 A 250 V, 10 piecesPB.5155 Microscope slides 76 x 26 mm, ground edges, 50 pieces PB.5165 Cover glasses 18 x 18 mm, thickness 0.13-0.17 mm, 100 pieces PB.5168 Cover glasses 22 x 22 mm, thickness 0.13-0.17 mm, 100 pieces PB.5245 Lens cleaning paper, 100 sheets per pack PB.5255 Immersion oil, n = 1.482 (25 ml) PB.5274 Isopropyl alcohol 99% (200 ml)PB.5275 C leaning kit: lens cleaning fluid, lint free lens tissue,brush, air blower, cotton swabsACCESSORIES AND SPARE PART S。
蔚仪金相显微镜使用说明

蔚仪金相显微镜使用说明引言:蔚仪金相显微镜是一种广泛应用于金属材料学、材料科学、矿物学等领域的高性能显微镜。
本文将详细介绍蔚仪金相显微镜的使用方法,以帮助用户正确操作该设备并获得准确的观察结果。
一、仪器结构蔚仪金相显微镜主要由光学系统、机械系统和照明系统组成。
光学系统包括目镜、物镜、眼镜和接眼镜等部分。
机械系统由支架、台座和移动平台组成,用于支撑和定位样品。
照明系统提供光源以照亮被观察的样品。
二、准备工作1. 将蔚仪金相显微镜放置在平稳的台面上,并确保其稳定。
2. 打开电源,检查照明系统是否正常工作。
3. 清洁镜头和目镜,确保视野清晰。
三、样品制备1. 准备待观察的金属材料样品,并将其切割成适当的大小。
2. 用金相试样粘合剂将样品固定在试样台上,确保样品表面平整。
3. 对样品进行打磨和抛光处理,以获得平滑的表面。
四、调节目镜1. 用合适的倍率的目镜观察样品,根据需要调整目镜的焦距,以获得清晰的观察图像。
2. 调节目镜的亮度和对比度,使图像更加清晰明亮。
五、调节物镜1. 选择适当的物镜倍率,根据需要调整物镜的焦距,以获得清晰的观察图像。
2. 调节物镜的亮度和对比度,使图像更加清晰明亮。
六、观察样品1. 将样品放置在显微镜的移动平台上,并使用调节旋钮将样品移动到所需的位置。
2. 使用焦距调节旋钮调整样品的焦距,以获得清晰的观察图像。
3. 通过调节亮度和对比度旋钮,使图像的亮度和对比度达到最佳状态。
4. 使用显微镜的放大功能,观察样品的微观结构和细节。
七、测量和分析1. 使用蔚仪金相显微镜的标尺功能,对样品进行测量,记录尺寸和形状参数。
2. 使用显微镜的图像采集功能,将观察到的图像保存到计算机或其他存储设备中,以便后续分析和处理。
八、维护和保养1. 每次使用后,及时清洁目镜和物镜,避免灰尘和污物的积累。
2. 定期检查显微镜的机械部件和光学系统,确保其正常工作。
3. 如有需要,校准显微镜的焦距和亮度,以保证观察结果的准确性和可靠性。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
坐在观察镜头后面,可以使观察者更能利用外部自然光, 更加自然地完成手眼配合,这对于精密检测任务、返工、 维修、解剖和其他操作来讲至关重要。
阅读人机工学方面的资料: /ergonomics »
Lynx EVO Brochure v1.1 Chinese.indd 5
所提供软件
摄像头参数 SMOS 1600 x 1200 像素 1/3” 2.8μm 8-bit 最大18.3fps BMP, JPEG, PNG 和 AVI uEye Cockpit (其他可用解决方案)
成像軟件
§ 附带软件提供快速注释和快速出具报告功能。 注释内容可以单独文件进行加载,并用于模板检查。
光学工艺 § Lynx EVO 融入了Dynascope® 专利技术. Dynascope®
技术优化了头部和身体的自由度,允许头部10mm的两边移 动和70mm的前后移动自由。
§ 6x - 60x 可使用物镜进行倍增, 总放大倍率可达120x。 10:1 变焦比。
§ 使用光圈控制连续变焦功能,以获得更理想的景深和对比 度。
§ 轻松捕捉图像,并压缩为 JPEG, PNG, 或非压缩版的 BMP 格式.
§ 以高兼容性AVI格式录制视频,并支持视频剪辑。
测量软件选项 DimensionOne™ 是 Lynx EVO 使用的一款强大的软件,具 有增强版的注释、屏上测量和标注功能。DimensionOne™
软件以CD形式随附,是屏上测量的理想软件。 查看其他可用软件。
Vision Engineering 从20世纪70年代开始引入了无目镜显微 镜,五十年风雨兼程,已经成为了光学系统的尖端企业。 自从无目镜显微镜产品问世以来,世界上的大部分顶级公司都 在使用,来完成日常的质量控制、零部件检测、提高效率和精 度等等任务。
虽然 Lynx EVO 的无目镜优势来自令人惊叹的3D(立体式)成像技术,
176mm 128mm 75mm 42mm 29mm
最小变焦下的 视场
55mm 40mm 25mm 16mm 12mm
最大变焦下的 视场
5.5mm 4.0mm 2.5mm 1.6mm 1.2mm
Lynx EVO Brochure v1.1 Chinese.indd 7
09/06/2015 19:54
1 绝佳的3D体视视图 通过人机工学性能,Lynx EVO 提供的绝佳3D视图。
专利无目镜光学技术使操作者可以在一定光路范围内,有效地 查看物体的3D视图,进而更深地查看。
2 相 比较传统带目镜显微镜,Lynx Evo 可以更自 然地观察物体
而无需两眼紧盯。从而阻碍了自然光的进入。 强烈的光线退 出目镜,会使瞳孔收缩。一般来说,长时间保持睁眼而关闭 瞳孔是引起眼部疲劳的主要因素,继而产生头痛和颈部肌肉疼 痛。 Lynx EVO 采用无目镜设计, 操作者可以坐在观察镜头后边, 允许自然光进入眼睛,从而更加自然地观察物体。
“没有任何一家公司能够像Vision一样,如此专注于提高显微镜的人机
工学功能,因为我们深深理解人机工学对于操作者的生产效率和质
” 量的重要性。
Lynx EVO Brochure v1.1 Chinese.indd 3
09/06/2015 19:54
提高生产率
Lynx EVO 是一款 高产能化无目镜显微镜, 通 过出色的3D视图观察功能,引爆企业的 产能. Lynx EVO装备有独特的 专利无目镜 光学件, 彻底把操作者从疲劳姿势中解放出来, 用无与伦比的人机工学性能开启了效率提升的 新时代。
§ 扩展延长可以适合更大的样品 (最大喉口深度可达 439mm)。力。 可轻松切换较高样品和平面样品。
技术参数
C
D A
E B
尺寸: A = 280mm B = 200mm C = 200mm max. D = 200mm max.
(less 工作距离**) E = 200mm
同的应用而进行功能定制。
§ 模块化设计,可根据具体应用而进行定制。 § 10:1 变焦比提供 6x-60x 的放大倍率,使用辅助镜头时最
大可达120倍。 § 集成HD摄像头/软件 (可选) 提供无缝图片/视频捕捉和标注
功能。
§ 简单的样品操作,长工作距离。 § 灵活的底座选项,适合于工业和生命科学应用。
4.2x (16x*) – 42x 35.5mm
10.2mm*
3.8mm
观察视角
垂直方向 34°
变焦范围
垂直观察
工作距离
最小变焦下 的视场
最大变焦下 的视场
6.8x (15x*) – 68x 56.5mm
12.0mm*
2.5mm
观察视角 -
* 不间断的
34° 360°
Lynx EVO Brochure v1.1 Chinese.indd 11
360° 旋转查看器
360° 旋转查看器
Lynx EVO 的360°旋转查看器是一款极 致的检测配件,允许对物体进行360°无 死角观察(34°角)。 用户可以在旋 转和垂直观察之前轻松切换。
Lynx EVO Brochure v1.1 Chinese.indd 9
辅台透射光照明
09/06/2015 19:55
09/06/2015 19:55
Lynx EVO 如何工作...
Dynascope® inside Lynx EVO 内置Vision Engineering获得全球专利的 Dynascope® 无目镜光学投影技术。Dynascope 技术摆脱
了传统显微镜的目镜,为用户提供出色的高对比度成像, 无与伦比的人机工学性能使操作变得更加轻松。
Dynascope® 技术解释了 Lynx EVO 是一款真实的光学体视显微镜。通过符合人机工学
要求的无目镜观察头体,可观察到未经处理的高分辨率真色光 学图像。 光线通过已获专利的Dynascope™光学器件,以双(单)光 程从单一的观察镜头射出。 这些岀射光线直径较大, 这意味着用户无需为了查看图像而将其眼睛精确对准观察镜头。 你可以看到令人大吃一惊的高分辨率3D体视图像。 无需目镜
Lynx EVO 与多 维底座协作。
Lynx EVO Brochure v1.1 Chinese.indd 4
体视显微镜的人机工 学性能怎么样?
09/06/2015 19:54
立刻体验人机工学的优点...
各大企业之所以选择英国工业显微镜公司的 Mantis,是因为他们清楚地知道,公司操作人 员会因此提高工作, 效率和精确性,从而提高 企业整体生产率。 因此,操作人员获利, 企业也获利。
Lynx EVO 底座选项
人机工学底座
§ 底座占地面积小。 § 高放大倍率任务更稳定。 § 显微镜辅台透射光照明(可选)支持多种样品的观察。 § 浮动平台 (可选) 为精确检查提供更为灵敏的控制,是易碎
样品和易被污染样品的理想检查工具。
多维底座
§ 精确和强劲,是大工作台需求工业领域应用的理想解决方案。
智能摄像头
方便进行图像/视频捕捉, 且二者皆可保存 光路 (用于同步体视观察)。
成像軟件 uEye 软件, 具有注释和标注功能。
网格线
网格线
使用 Lynx EVO 可使用交叉瞄准线和测 量网格线功能。
借助测量网格线,观察样品的同时, 可进行快速、简单的测量。
可进行网格线自定义.
辅台透射光照明
显微镜辅台透射光照明(可选)支持多种 样品的观察。光源选择多样化,可选透射 光和入射光。
使用 Lynx EVO 工作更高效。
09/06/2015 19:54
Lynx EVO - 通过无目镜技术提高产能
还可以佩戴眼镜 3
7 方便手眼配合
4 保护样品不受交叉感染和 污染
绝佳的3D 1 (体视) 视图
人机工学 5 工作 位置
6 头部活动的自 由度
2 以较为自然的方式观 察物体
Lynx EVO Brochure v1.1 Chinese.indd 6
净重: 15.3kg Packed 重量: 19.5kg
人机工学底座
Lynx EVO Brochure v1.1 Chinese.indd 8
H
I J G
F
多维底座
尺寸: F = 455mm G = 635mm H = 425mm max. I = 最大750mm,工作距离较短) J = 439mm max.
5 符合人机工学要求的操作位置 不仅使 Lynx EVO 用起来舒适无疲劳,而且操作更加简易。
此外,最优的人机工学设计还能将身体劳损等相关伤害的复发 风险降至最低。 快乐的员工更多产。
6 头部可以自由活动
是英国显微镜公司的专利目镜的另一个好处,使用者不需要把 眼睛精确对准目镜的观察镜头上。 头部可以自由活动就减少 了颈部和背部的疼痛,长时间固定的姿势会造成人体血液流通 不畅,从而造成疲劳,这也是传统显微镜与无目镜显微镜所无 法匹敌的一方面。
09/06/2015 19:54
无目镜的优势
Lynx EVO 内置了革命性的 Dynascope® 技术, 通过无与伦比的 人机工学和方便使用改善了生产率。
§ 超强的人机工学改善了产能和效率。
§ 以较为自然的方式观察物体 可用于 方便手眼配合.
Lynx EVO 产品详细信息
产品优势 除了无与伦比的人机工学优势之外,Lynx EVO 还可以根据不
但这种专利设计的真正亮点在于操作上的简便。 没有任何一 家公司能够像我们这样,如此专注于提高显微镜的人机工学功 能,因为我们深深理解人机工学对于操作者的生产效率和质量 的重要性。
Lynx EVO 是一款非常符合人机工学的产品。 操作者从舒适度 方面得到实惠,而企业则从生产率和质量方面获益。
阅读人机工学方面的资料: /ergonomics »