二氧化碳CO2传感器参数
Belimo 22DC-11 二氧化碳气体传感器技术数据表说明书
22DC-11Duct sensor CO₂Active sensor (0...10 V) for measuring CO₂. Dualchannel CO₂ technology. IP65 / NEMA 4X ratedenclosure.Type OverviewType Output signal active CO₂22DC-110...5 V, 0...10 VTechnical dataElectrical data Nominal voltage AC/DC 24 VNominal voltage range AC 19...29 V / DC 15...35 VPower consumption AC 4.3 VAPower consumption DC 2.3 WElectrical connection Pluggable spring loaded terminal block max.2.5 mm²Cable entry Cable gland with strain relief ø6...8 mmFunctional data Application AirVoltage output 1 x 0...5 V, 0...10 V, min. resistance 10 kΩOutput signal active note Output 0...5/10 V with Jumper adjustableMeasuring data Measured values CO₂Specification CO₂Sensing element technology NDIR (non dispersive infrared) dual channelMeasuring range0...2000 ppmAccuracy±(50 ppm + 3% of measured value)Long term stability±50 ppm p.a.Time constant τ (63%) in the air duct Typical 33 s @ 1 m/sSafety data Protection class IEC/EN III, Safety Extra-Low Voltage (SELV)Power source UL Class 2 SupplyDegree of protection IEC/EN IP65Degree of protection NEMA/UL NEMA 4XEnclosure UL Enclosure Type 4XEU Conformity CE MarkingCertification IEC/EN IEC/EN 60730-1Quality Standard ISO 9001UL Approval cULus acc. to UL60730-1A/-2-9, CAN/CSAE60730-1/-2-9Type of action Type 1Rated impulse voltage supply0.8 kVPollution degree3Ambient humidity Max. 95% RH, non-condensingSafety data Ambient temperature0...50°C [32...122°F]Fluid humidity Max. 95% RH, non-condensingFluid temperature0...50°C [32...122°F]Operating condition airflow min. 0.3 m/smax. 12 m/sMaterials Cable gland PA6, blackHousing Cover: PC, orangeBottom: PC, orangeSeal: NBR70, blackUV resistantProbe material PA6, blackSafety notesThis device has been designed for use in stationary heating, ventilation and air-conditioningsystems and must not be used outside the specified field of application. Unauthorisedmodifications are prohibited. The product must not be used in relation with any equipmentthat in case of a failure may threaten humans, animals or assets.Ensure all power is disconnected before installing. Do not connect to live/operatingequipment.Only authorised specialists may carry out installation. All applicable legal or institutionalinstallation regulations must be complied with during installation.The device contains electrical and electronic components and must not be disposed of ashousehold refuse. All locally valid regulations and requirements must be observed. RemarksGeneral remarks concerning sensors Sensing devices with a transducer should always be operated in the middle of the measuringrange to avoid deviations at the measuring end points. The ambient temperature oftransducer electronics should be kept constant. The transducers must be operated at aconstant supply voltage (±0.2 V). When switching the supply voltage on/off, onsite powersurges must be avoided.Remark: Occurring draft leads to a better carrying-off of dissipative power at the sensor. Thustemporally limited fluctuations might occur upon temperature measurement.Requirements to be met by the medium To ensure the ongoing and optimal functioning of the sensor, it is imperative that the airbeing measured is free of dust or other contaminants that could accumulate on the sensorelement.Information self-calibration feature CO₂All CO₂ sensors are subject to drift caused by the aging process of the components, resultingin regular re-calibration or replacement of units. However, the dual channel technologyintegrates automatic self-calibration technology vs. commonly used ABC-Logic sensors. Dualchannel self-calibration technology is ideally suited for applications operating 24/7 hours suchas those in hospitals or other commercial applications. Manual calibration is not required. Parts includedDescription TypeMounting flange for duct sensor 19.5 mm, up to max. 120°C [248°F],A-22D-A35PlasticAccessoriesOptional accessories Description TypeReplacement filter sensor probe tip, wire mesh, Stainless steel A-22D-A06Description TypeA-22G-A01.1Connection adapter flex conduit, M20x1.5, for cable gland 1x 6 mm,Multipack 10 pcs.Mounting plate L housing A-22D-A10 Wiring diagram① Status LED22DC-11 DimensionsType Probe length Weight22DC-11150 mm0.26 kgFurther documentation• Installation instructions。
二氧化碳气体传感器 MH-Z14 使用说明书
二氧化碳气体传感器(型号:MH-Z14)使用说明书版本号:2.6实施日期:2016.05.05郑州炜盛电子科技有限公司Zhengzhou Winsen Electronic Technology Co., Ltd声明本说明书版权属郑州炜盛电子科技有限公司(以下称本公司)所有,未经书面许可,本说明书任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段进行传播。
感谢您使用炜盛科技的系列产品。
为使您更好地使用本公司产品,减少因使用不当造成的产品故障,使用前请务必仔细阅读本说明书并按照所建议的使用方法进行使用。
如果您不依照本说明书使用或擅自去除、拆解、更换传感器内部组件,本公司不承担由此造成的任何损失。
您所购买产品的颜色、款式及尺寸以实物为准。
本公司秉承科技进步的理念,不断致力于产品改进和技术创新。
因此,本公司保留任何产品改进而不预先通知的权力。
使用本说明书时,请确认其属于有效版本。
同时,本公司鼓励使用者根据其使用情况,探讨本产品更优化的使用方法。
请妥善保管本说明书,以便在您日后需要时能及时查阅并获得帮助。
郑州炜盛电子科技有限公司MH-Z14二氧化碳气体传感器产品描述MH-Z14二氧化碳气体传感器(以下简称传感器)是一个通用智能小型传感器,利用非色散红外(NDIR)原理对空气中存在的CO2进行探测,具有很好的选择性和无氧气依赖性,寿命长。
内置温度补偿;同时具有数字输出与模拟电压输出,方便使用。
该传感器是将成熟的红外吸收气体检测技术与精密光路设计、精良电路设计紧密结合而制作出的高性能传感器。
传感器特点高灵敏度、高分辨率、低功耗提供UART、模拟电压信号、PWM波形等多种输出方式响应时间快温度补偿,卓越的线性输出优异的稳定性使用寿命长抗水汽干扰、不中毒主要应用可广泛应用于暖通制冷与室内空气质量监控、工业过程及安全防护监控、农业及畜牧业生产过程监控。
技术指标表1产品型号MH-Z14检测气体二氧化碳工作电压 4.5~5.5 V DC平均电流< 85 mA接口电平 3.3 V测量范围0~5%VOL范围内可选(详见表2)输出信号0.4~2 V DCUARTPWM预热时间 3 min响应时间T90< 90 s工作温度0~50 ℃工作湿度0~95% RH (无凝结)外形尺寸57.5 mm×34.7 mm×17 mm(L×W×H)重量15 g寿命> 5年常用量程和精度产品尺寸图图1 传感器结构图引脚定义图2 管脚定义图表2气体名称分子式量程 精度 备注 二氧化碳CO 20~2000 ppm±(100ppm+ 6%读数值)温度补偿 0~5000 ppm 温度补偿 0~1% Vol 温度补偿 0~3% Vol 温度补偿 0~5% Vol温度补偿MH-Z14引脚定义 表3管脚名称 管脚说明 Pad1、 Pad15、Pad17 Vin 电压输入Pad2、Pad3、 Pad12、Pad16GNDPad4 Vout2 (0.4~2 V) Pad5 Vout1 (0~2.5 V)Pad6 PWMPad8 HD (校零,低电平7秒以上有效)Pad7、 Pad9NCPad11、Pad14、Pad18 UART (RXD ) 0~3.3 V 数据输入 Pad10、Pad13、Pad19 UART (TXD ) 0~3.3 V 数据输出输出方式PWM 输出假设测量范围为0~2000ppm CO 2浓度输出范围 0~2000ppm 周期1004ms±5% 周期起始段高电平输出 2ms(理论值) 中部周期1000ms±5% 周期结束段低电平输出2ms(理论值)通过PWM 获得当前CO 2浓度值的计算公式:C ppm =2000×(T H -2ms)/(T H +T L -4ms) C ppm 为通过计算得到的CO 2浓度值,单位为ppm T H 为一个输出周期中输出为高电平的时间 T L 为一个输出周期中输出为低电平的时间模拟电压输出Vout 输出电压范围(0.4~2V ),对应气体浓度(0~满量程)将传感器Vin 端接5V ,GND 端接电源地,Vout 端接ADC 的输入端。
CRIR E1商业二氧化碳传感器说明书
CRIR E1Commercial Carbon Dioxide (CO2) Sensor, 400 ppm to 2000 ppm,up to 5000 ppm Extended Range DESCRIPTIONThe CRIR E1 Commercial CarbonDioxide (CO2) sensor is a single channel,non-dispersive infrared (NDIR) sensor.Within the CRIR E1 is a sensing chamberwith an infrared source at one end anda detector fitted with an optical filterat the other end. The source emitsradiation at wavelengths which includethe absorption band of CO2. The filter blocks wavelengths which are notsensitive to the presence of CO2, thereby increasing selectivity and sensitivity.As the light passes through the sensingchamber, a fraction is absorbed if CO2is present. The difference between the light emitted by the source and received by the detector can then be converted toa CO2concentration reading.The Automatic Baseline Correction (ABC) function can automatically calibrate the sensor’s lowest reading over a pre-configured interval to400 ppm CO2. This enhances long term stability and may eliminate the need for calibration.FEATURES• Single channel, non-dispersive infraredtechnology• Automatic Baseline Correction• Temperature compensation• UART digital interfaceVALUE TO CUSTOMERS• Small size• Maintenance free for normal indoorapplications• Enhanced long term stability• Higher accuracy: ±50 ppm ±5% ofreading• Consistency and repeatability• Easy integrationPOTENTIAL APPLICATIONS• HVAC, demand controlled ventilation• Indoor air quality (IAQ) measurement• Air purification systems• Smart /IoT (Internet of Things) systems2Sensing and Internet of Things1The CRIR E1 is designed to measure CO 2 in the range of 400 ppm to 2000 ppm with the accuracy specified in Table 1; however, exposure to concentrations below 400 ppm may result in incorrect operation of the ABC algorithm and should be avoided when the ABC is ON.2 The CRIR E1 provides readings via UART in the extended range; however, the accuracy is reduced.3 In normal IAQ applications, the sensor accuracy is defined after a minimum of three ABC periods of continuous operation.4The sensor accuracy is specified over the operating temperature range and referenced to certified calibration mixtures.Uncertainty of calibration gas mixtures (±1% currently) is to be added to the specified accuracy for absolute measurements.5 See the CRIR E1 User Guide for Modbus address and parameter definitions.6The CRIR E1 normally does not require maintenance in IAQ applications; however, for some industrial applications, maintenance may be required.FIGURE 1. ALARM STATE DIAGRAM2Alarm state open3Sensing and Internet of ThingsFIGURE 2. MOUNTING DIMENSIONS (FOR REFERENCE ONLY: MM)000838-1-EN | 1 | 08/19© 2019 Honeywell International Inc. All rights reserved.HoneywellSensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707www. WARRANTY/REMEDYHoneywell warrants goods of itsmanufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While Honeywell may provideapplication assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application.Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.m WARNINGPERSONAL INJURYDO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.Failure to comply with theseinstructions could result in death or serious injury.m WARNINGMISUSE OFDOCUMENTATION•The information presented in this product sheet is for referenceonly. Do not use this document as a product installation guide.•Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.Failure to comply with theseinstructions could result in death or serious injury.ADDITIONAL MATERIALSThe following associated literature is available at :• CRIR E1 User GuideFOR MORE INFORMATIONHoneywell Sensing and Internet ofThings services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit or call:Asia Pacific +65 6355-2828Europe +44 1698 481481USA/Canada+1-800-537-6945。
二氧化碳浓度传感器二氧化碳CO2浓度传感器
二氧化碳浓度传感器二氧化碳CO2浓度传感器二氧化碳CO2泄露检测探测器产品适用于各种环境和特殊环境中的二氧化碳CO2气体浓度和泄露,在线检测及现场声光报警,对危险现场的作业安全起到了预警作用,此仪器采用进口的电化学传感器和微控制器技术,具有信号稳定,精度高,重复性好等优点,防爆接线方式适用于各种危险场所,并兼容各种控制器,PLC,DCS等控制系统,可以同时实现现场报警和远程监控,报警功能,4-20mA 标准信号输出,继电器开关量输出。
二氧化碳浓度传感器二氧化碳CO2浓度传感器产品特性:气体传感器参数工作电压DC5V±1%/DC24±1%波特率9600测量气体二氧化碳CO2气体检测原理电化学采样精度±2%F.S 响应时间<30S重复性±1%F.S 工作湿度10-95%RH,(无冷凝)工作温度-30~50℃长期漂移≤±1%(F.S/年)存储温度-40~70℃预热时间30S 工作电流≤50mA 工作气压86kpa-106kpa安装方式7脚拔插式质保期1年输出接口7pIN 外壳材质铝合金使用寿命2年外型尺寸(引脚除外)33.5X3121.5X31测量范围详见选型表输出信号TTL(标配)0.4-2.0VDC(常规)/4-20mA数字信号格式数据位:8;停止位:1;校验位:无;①进口电化学传感器具有良好的抗干扰性能,适用寿命8年。
②采用先进微处理技术,响应速度快,测量精度高,稳定性和重复性好。
③检测现场具有具有现场声光报警功能,气体浓度超标即时报警,是危险场所作业的安全保障。
4现场带背光大屏幕LCD显示,直观显示气体浓度,类型,单位,工作状态等。
5独立气室,更换传感器无须现场标定,传感器关键参数自动识别。
6全量程范围温度数字自动跟踪补偿,保证测量准确性。
二氧化碳浓度传感器二氧化碳CO2浓度传感器技术参数:检测气体:空气中的二氧化碳CO2气体检测范围:0~50ppm,0~500ppm,0~1000ppm可选。
COT 212-R 温度与二氧化碳传感器数据手册说明书
(1)Features• Power supply 24 Vdc/Vac or 100-240 Vac • Trend indicator• “¼ turn” system mounting withwall-mount plate4-wire analogue output 0-5/10 V or 0/4-20 mA Configurable ranges from 0 to 5000 ppm and from 0 to 50 °C ABS V0 IP65 housing, with or without display2 relay outputsPart numberExample: COT212 – BNS – RTemperature and CO 2 transmitter, 24 Vac/Vdc power supply, without display, with ambient probe and relay outputs Important note:The model with power supply of 24 Vac/Vdc is available only without display.The model with power supply of 100-240 Vac is available only with display.Power supply / Output B : 24 Vac/Vdc H : 100-240 VacDisplayN : without display (only for models with power supply of 24 Vac/Vdc)O: with display (only for models with power supply of 100-240 Vac)Type of probe D : Remote S : AmbientProbe cable length (remote model only) ( ): cable lentgh 2 m 05M: cable length 5 m 10M: cable length 10 mRelay outputsWarning: risk of electric shock 2 x 4-20 mA or 2 x 0-20 mA or 2 x 0-5 V or 2 x 0-10 V (4 wires)DOUBLE ISOLATION or REINFORCED ISOLATIONFeatures of housingAll dimensions are in millimeters.Probes technical specifications• Ambient probeRemote modelAmbient modelDimensionsConnections50-60 Hz 8 VA 0/4...20 mA / 0...5/10 V1234576l t a j e i e r r a e n t el t a j ei e r r a e n t e24 Vdc NL Alimentation 100-240 Vacor1. DIP switch (d)2. LCC-S software connection3. Relays4. Analogue outputs (a)5. F3.20* fuse6. Power supply terminal block (c)7. Cable glandsOn 100-240 Vac models, if a fuse protection is used for the power line, it is imperative to use delayed-action fuses in order to • •• N L Alimentation 24 Vacclasse II norme EN61558-2-6Pe N L ou230 Vacor230 VacNL Alimentation 100-240 Vac-+0-5/10 V0/4-20 mAAf cheur régulateur ou automate type passifAf cheur régulateur ou automate type passifSortie 4-20 mASortie 0-10 VPLC/BMS de tipo pasivoConfiguration of the transmittersIt is possible on the class 210 to configure all the parameters of the transmitter : units, measuring ranges, outputs, channels, calculation func-tions, etc, via different methods:• Keypad for models with display: a code-locking system allows to secure the installation (See class 210 transmitters user manual). • Software (optional) on all models: Simple user-friendly configuration. See LCC-S user manual.Sorties analogiques configurables: Configurable analogue output:It is possible to configure your own intermediary ranges in CO 2 and in temperature.Caution: the minimum difference between the high range and the low range is 20.37500 ppm 0 V 4 mA 2500 ppm 5000 ppm10 V 20 mANew range0 ppm0 V 4 mA 25005000 ppm10 V 20 mA3750MountingTo mount the transmitter, mount the ABS plate on the wall (drilling: Ø 6 mm, screws and pins are supplied).Insert the transmitter on the fixing plate (see A on the drawing beside). Rotate the housing in clockwise direction until you hear a “click” which confirms that the transmitter is correc-tly installed.MaintenancePlease avoid any aggressive solvent. Please protect the transmitter and its probes from any cleaning product containing formalin, that may beused for cleaning rooms or ducts.CalibrationOutputs diagnostic: With this function, you can check with a multimeter (or on a regulator / display, or a PLC / BMS) if the transmitter out-puts work properly. The transmitter generates a voltage of 0 V , 5 V and 10 V or a current of 4 mA, 12 mA and 20 mA.Certificate: Class 210 transmitters are supplied with adjusting certificates. Calibration certificates are available as an option.Options and accessoriesPrecautions for usePlease always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device.Only the accessories supplied with the device must be used.All dimensions are in millimeters.F T _E N – C O T 212-R – 02/08/2021 – N o n -c o n t r a c t u a l d o c u m e n t – W e r e s e r v e t h e r i g h t t o m o d i f y t h e c h a r a c t e r i s t i c s o f o u r p r o d u c t s w i t h o u t p r i o r n o t i c e .。
二氧化碳检测器常用使用说明书
二氧化碳检测器常用使用说明书
1.产品概述:
由于二氧化碳无色无味,一般情况下很难检测,而且过多吸入会引起人体不适或影响生物的生长。
二氧化碳检测器是一款用于检测二氧化碳浓度的仪器,具有高精度、长寿命、体积小,易维护等特点,广泛应用于各个领域如发酵过程控制,农业暖房、温室CO2浓度监测。
多种输出方式可选。
2.产品参数:
探测范围:350 to 10000ppm.
传感器灵敏度:ΔEMF=30~50mV(EMF350ppmCO2-EMF10000ppmCO2).
工作电源:DC12V~DC24V.
输出:4-20mA,0-5V。
RS485(可选)
负载电阻:≦100欧姆。
功耗:小于1W
工作温度:-30°C--85°C
工作湿度:5-- 95%
电气接口:4针航空头
体积:90*85*30 (mm)
安装方式:壁挂式
3.接线说明:
蓝色VCC :电源输入
棕色GND:电源地
黄色A+ :电流输出正
黑色GND:电源地
4.型号:KTR-CO2
5.品牌:KITOZER(开拓者)。
485 型二氧化碳 三合一传感器 使用说明书
485型二氧化碳三合一传感器使用说明书第1章产品简介1.1产品概述该变送器广泛适用于农业大棚、花卉培养等需要CO2、光照度及温湿度监测的场合。
传感器内输入电源,感应探头,信号输出三部分完全隔离。
安全可靠,外观美观,安装方便。
1.2功能特点本产品采用高灵敏度的气体检测探头,信号稳定,精度高。
具有测量范围宽、线形度好、使用方便、便于安装、传输距离远等特点。
A、CO2温湿度三合一(普通版):只适用于室内、平缓环境。
B、CO2温湿度三合一(带外置探头版):适用于室内、室外均可,外壳IPV65全防水,可应用于各种恶劣环境。
1.3主要参数1.3.1CO2参数CO2精度±(50ppm+3%读数)(25℃)非线性<1%F·S预热时间2min(可用)10min(最大精度) 1.3.2温湿度参数1.3.3温度参数表一不同温度下温度测量精度如上表所示,在5-60摄氏度范围内最大偏差在±0.5内,小于0℃和大于60摄氏度情况下偏差递增。
1.3.4湿度参数内容最小值典型值最大值单位分辨率(12bit)-0.04-%RH 线性偏差-±3.0见后表2%RH 重复度-±0.1-%RH 工作范围0-100%RH 响应时间(63%)-8-秒长期漂移-<0.5-%RH/年滞后性-±1-%RH 非线性度-<0.1-%RH表二不同湿度下湿度测量精度如上表所示,在20-80%RH范围内典型偏差±3%,小于20%和大于80%的湿度情况下情况下偏差递增。
1.3.5温度对湿度测量的影响上文表二描述了不同湿度情况对湿度测量的影响,下表描述了不同的温度对湿度测量精度的影响。
表三不同温度下的相对湿度如上表所示,在15摄氏度到55摄氏度,30到80的湿度范围内,湿度的精度最高,是±4.5%,其余情况湿度递增。
1.4探头参数与选型CO2探头选型如下:型号量程精度是否抗高预热时间响应时间5KN5000ppm±(50ppm+5%)×<120S<30S 5KW5000ppm±(50ppm+5%)√<60S<15S 1BW1%±(50ppm+5%)√<60S<15S 3BW3%±(50ppm+5%)√<60S<15S 65B65%±(50ppm+5%)×<30S<15S 100B100%±(50ppm+5%)×<30S<15S1.5系统框架图第2章硬件连接2.1设备安装前检查安装设备前请检查设备清单:12V 防水电源1台(选配)USB 转485设备1台(选配)保修卡/合格证1份2.2接口说明宽电压电源输入12-24V 均可。
二氧化碳传感器使用说明书
产品简介二氧化碳传感器采用进口传感芯片,用于检测各种环境中CO2的浓度,具有精度高、稳定性好等特点。
信号变送器采用先进的集成电路模块,可根据用户的不同需求输出电压、电流等信号。
仪器体积小巧,安装方便且便携,性能可靠;采用专有线路,线性好,负载能力强,传输距离长,抗干扰能力强。
本产品可广泛用于办公楼、公共场所、温室大棚、生产厂房等场所二氧化碳浓度的检测。
技术参数量程范围:0~2000ppm准确度:±(40ppm+2%F•S)分辨率:1ppm供电方式:□DC 5V□DC 12V□DC 24V□其他输出形式:□电流:4~20mA□电压:0~4V□RS232□RS485□TTL电平:(□频率□脉宽)□其他仪器线长:□标配:2.5米□其他负载电阻: 电压型:RL≥1K电流型:RL≤250Ω工作温度:-40℃~70℃相对湿度:0~100%产品重量:140g产品功耗:4.8mW 计算公式电压型(0~4V):C= V / 4 × 2000(C为测量二氧化碳浓度值(ppm),V为输出电压(V))电流型(4~20mA输出):C=(I-4 )/ 16 × 2000(C为测量二氧化碳浓度值(ppm),I为输出电流(mA))接线方法(1)若配备本公司生产的气象站,直接使用传感器线将传感器与气象站上的相应接口相连即可。
(2)若单独购买变送器,变送器配套线线序分别为:红色:电源+黄色:输出信号绿色:电源—(3)变送器电压、电流两种输出接线方式:(电压输出方式接线)(电流输出方式接线)结构尺寸变送器尺寸66 m m49 m m 98 mm使用说明将传感器按接线方法中的说明接线,然后置于欲测量二氧化碳浓度的位置,打开电源和采集仪开关,即可获取测量点二氧化碳浓度。
RS485(带地址)通讯协议一、串口格式 数据位 8位 停止位 1位 校验位 无波特率 9600 两次通信间隔至少1000ms 以上 二、通讯格式【1】写入设备地址发送: 00 10 00 AA (16进制数据) 说明: 00 - 广播地址(必须为0) 10 - 写入操作(固定) 00 - 地址命令(固定)AA - 写入的新地址(唯一,1-255)返回: OK (OK 表示返回成功)【2】读取设备地址发送: 00 03 00(16进制数据) 说明: 00 - 广播地址(必须为0) 03 - 读取操作(固定) 00 - 地址命令(固定)返回: Address = XXX (ASCII 码数据,如Address = 001,Address = 123等)说明: Address - 地址指示XXX - 地址数据,不足3位整数时,前面补0;[1]其中单位后面跟一回车换行数据,两个字节,16进制数据为0x0D 0x0A ;[2]上述说明中忽略了空格和'='等过渡字符。
煤矿二氧化碳传感器参数
煤矿二氧化碳传感器参数煤矿是一种密闭环境,矿工在其中进行工作时,可能会暴露在有害气体中,其中最常见的是二氧化碳。
二氧化碳是一种无色、无味的气体,高浓度的二氧化碳可以导致人体中毒。
为了确保矿工的安全,煤矿通常会安装二氧化碳传感器,以监测矿井中的二氧化碳浓度。
二氧化碳传感器是一种电子设备,能够测量周围环境中二氧化碳的浓度,并将测量结果转化为电信号,以便监测和控制系统进行处理。
以下是一些常见的煤矿二氧化碳传感器的参数:1. 灵敏度(Sensitivity):传感器的灵敏度指的是在单位浓度下,传感器输出信号的变化量。
通常以ppm/vol或ppm/mV为单位。
灵敏度越高,传感器对二氧化碳的浓度变化越敏感。
2. 测量范围(Measurement Range):传感器能够测量的二氧化碳浓度的范围。
煤矿二氧化碳传感器的测量范围通常在0~5000 ppm之间。
需要注意的是,不同的传感器可能有不同的测量范围。
3. 线性度(Linearity):传感器的线性度指的是传感器输出信号与实际浓度之间的相关性。
线性度越高,传感器的输出信号与实际浓度的误差越小。
4. 响应时间(Response Time):传感器的响应时间指的是传感器达到输出信号的稳定状态所需的时间。
煤矿中,响应时间是一个非常关键的参数,因为需要及时监测到高浓度的二氧化碳以防止事故发生。
5. 灵敏度漂移(Sensitivity Drift):传感器的灵敏度漂移指的是传感器在使用过程中,灵敏度的变化量。
灵敏度漂移会导致传感器输出信号的准确性下降,因此需要定期进行校准。
6. 工作温度范围(Operating Temperature Range):传感器能够正常工作的温度范围。
煤矿二氧化碳传感器的工作温度范围通常在-20℃~50℃之间。
7. 工作湿度范围(Operating Humidity Range):传感器能够正常工作的湿度范围。
煤矿二氧化碳传感器的工作湿度范围通常在0~95% RH之间。
比较选型:CO2浓度传感器
CO2浓度传感器选型表【需在查询中完善……】型号EHT-R4 MG811 T6613红外二氧化碳传感器TGS4160GRG5H型红外二氧化碳传感器MH-Z14原理(非色散红外(NDIR)原理)(电化学原理)(非色散红外(NDIR)原理)(非色散红外(NDIR)原理)(非色散红外(NDIR)原理)(非色散红外(NDIR)原理)规格传感器尺寸:40mmX25mmX35mm 传感器尺寸:57.15mm*34.67mm*15.24mm产品尺寸:最大外径Φ24mm,高24mm,引脚长5.8mm。
1280MM×160MM×68MM专门用以监测煤矿井下二氧化碳气体的本质安全型检测仪表仪器57.5*34.7*16mm(L*W*H)供电24VDC 6V 5V 5±0.2v DC (9~25)V. 4.5-5.5VDC准确度± 30 ppm±5% 可由AD决定40PPM+2%读数@1250PPM ±0.30% CO2 ± 50 ppm±5%的读数值量程: 0~2000 ppm 0~100000ppm 0-2000ppm 0~5000ppm 0~5000ppm 0~2000ppm或0~5000ppm工作的温湿度范围0~50℃,0~95%RH(无凝结)60℃以上0~50℃0~95%RH非凝露0~50℃0~95%RH非凝露0~50℃0~95%RH非凝露0~50℃0~95%RH非凝露长期稳定性湿度<1%RH/年稳定稳定稳定稳定稳定响应时间<30S 达到变化的 90% 探头预热时间为2-5分钟小于2分钟2小时小于20秒小于一分半钟输出信号网络485输出模拟电压信号0-2V 数字信号:UART@19200波特数字方式输出模拟信号:0.8~4V 模拟信号:0-3V相当于0-3000PPM200HZ~1000HZ/5~15HZ4~20MA/1~5MA/RS485总线0.4~2V模拟信号UART PWM功耗正常<50ma功耗1200mw 未说明 1.25W 直流18V小于150MA 2.7W0.425W左右价格1000元单个探头165左右模块的 260元左右未说明,正在询价中。
JX-CO2-102红外二氧化碳传感器模组使用说明书
红外二氧化碳模组传感器使用说明书JX-CO2-102Ver1.0一站式物联网供应平台第1章产品简介1.1产品概述JX-CO2-102系列是利用非分散性红外线技术(NDIR)测量二氧化碳的一种传感器。
红外光源发出的红外辐射经过一定浓度待测的气体吸收之后,与气体浓度成正比的光谱强度会发生变化,因此求出光谱光强的变化量就可以反演出待测气体的浓度。
红外二氧化碳传感器模组是采用NDIR红外吸收检测原理,将先进光路、精密电路与智能化软件相结合,形成一款通用型红外CO2传感器模组。
本产品采用进口红外光源和双通道热电堆探测器,对测量和参考信号的处理,并对进行温度补偿,即使在恶劣的温度和环境条件下,也能获得稳定可靠的测量结果。
具有NDIR产品特有的良好选择性,高灵敏度,无氧气依赖性,寿命长等特点。
JX-CO2-102系列产品采用镀金工艺制作而成。
本产品可广泛应用于暖通制冷换新风控制、室内空气质量监测、农业及畜牧业生产过程监控,可安装于智能楼宇、通风系统、控制器、壁挂使用、机器人、汽车等应用场合。
1.2参数指标测量精度50ppm或±5%F.S(25℃)2响应时间<30s(25℃)预热时间<1min(25℃)达到精度<5min(25℃)工作电压5V DC平均耗电<60mA)工作湿度0~95%RH(非凝露JX-CO2-102-1W0-10000ppmJX-CO2-102-3W0-30000ppmJX-CO2-102-5W0-50000ppm1.4引脚定义JX-CO2-102系列红外二氧化碳的引脚定义如下表(图)所示:3一站式物联网供应平台4备注:传感器接口为7Pin-1.25mm 插座和7Pin-2.54mm 排针连接。
1.5产品外观下图是产品的外观和结构尺寸图,以及安装孔位,如图所示:本产品安装固定孔位间距为46mm,孔径为3.5mm;第2章通信协议2.1通信参数数据位8位才会恢复当前浓度值。
奥松 ACD10红外二氧化碳传感器产品说明书
ACD10产品说明书红外二氧化碳传感器•优异的长期稳定性•良好的选择性•无氧气依赖性•标准数字输出•响应迅速•恢复时间快•抗干扰能力强产品综述ACD10利用非分散红外(NDIR)原理对空气中的二氧化碳浓度进行检测。
ACD10具有良好的选择性、无氧气依赖性、寿命长等优点;具备数字接口输出,方便使用。
ACD10是一款集成红外吸收气体检测技术、精密光路和高精度信号检测电路的高性能传感器。
应用范围ACD10的应用场景广泛,适用于空气质量监控设备、新风系统、空气净化设备、暖通制冷设备等。
图1.ACD10实物图1.工作原理ACD10传感器是基于CO2气体的光谱吸收原理设计而成的。
如图2所示,传感器有光源、气室和红外传感器三个部分组成。
红外传感器是用于测量光源发射的红外线强度,当CO2通过气体进气口流入气室,从出气口流出气室,CO2会吸收气室内特定波长的红外光,且CO2的浓度变化会对红外吸收量有影响。
当CO2的浓度发生变化时,红外线传感器接收到的光源信号强度也会发生变化。
传感器通过检测特定波长的红外光的吸收率,计算得出CO2浓度。
图2.ACD10工作原理图2.技术指标表1.技术指标参数表用户指南1.校准功能说明传感器有自动校准和手动校准功能,用户可以通过主机发送命令(见2.3.2和2.4.3命令列表)进行选择。
传感器出厂时默认设置为自动校准模式。
1.1自动校准功能传感器内置自动校准算法,可以周期性地自动校准并修正测量误差。
传感器在上电24小时后,完成一次自动校准,此后每7天(168小时)完成一次自动校准。
为了确保校准后的精度,请在上电后24浓度至少有1小时接近室外大气水平。
小时内和连续工作的7天内,传感器的工作环境中CO21.2手动校准功能将传感器放置于已知CO2浓度的工作环境中20分钟以上,通过主机发送手动校准命令(见2.3.2和2.4.3命令列表)。
2.接口定义及通信协议2.1ACD10引脚分配图3.ACD10引脚图表2.引脚定义表2.2通讯接口传感器提供I2C、UART通信接口,用户可根据需要自行选择,接口输入电平兼容3V到5V,输出电平内部上拉到5V。
AQC系列红外CO2传感器产品规格手册说明书
产品规格手册红外二氧化碳传感器 AQC 系列·CO2浓度范围:0‐5000 PPM ·基于NDIR 红外吸收原理 ·高精度:±50PPM ±5% ·带有温度补偿功能 ·多种接口(UART/PWM/模拟) ·响应时间:120s(90%) ·极佳的稳定性和可靠性 ·支持定制化需求·高效扩散型内部流场 ·红外聚焦技术 ·低衰减漫反射光路技术1. 产品概述2. 产品典型应用领域AQC 系列CO2传感器产品针对环境CO2浓度检测等多领域的应用场景开发,采用自然扩散式进气方式和单波长的红外吸收原理,具有稳定可靠、高性价比的显著特点 AQC 系列CO2传感器集成专业的NDIR 技术,采用国际领先的高品质红外光源和光学传感器,并具有独特的测量和温度补偿算法,与市场现有产品相比,具有稳定性更好、漂移微小、温度稳定性好、响应时间快等优势AQC 系列CO2传感器采用标准5V 供电,可选数字UART 、PWM 信号或线性模拟信号输出,且具有优良的抗干扰性能,有利于产品的集成应用AQC 系列CO2传感器可根据客户要求提供可定制化方案。
包括量程,输出形式,精度要求都可定制开发,以满足不同的客户需求 ·环保领域:环境大气检测、空气净化等 ·家电:空气净化器,新风系统 ·仪器仪表:手持式或者桌面式空气检测仪 ·通风及换气:HVAC 换气系统 ·汽车:车内CO2监测3.产品性能参数 规格性能 备注说明 CO2测量范围 0-5000PM/0-2000PPM/0-10000PPM 可定制CO2分辨率 1PPM /CO2测量精度(1±50ppm±5% of reading 可定制更高精度 响应时间 120S 从零点到90%满量程 注:1) 环境温度为25度,大气压为101.3Kpa,湿度50% RH,使用标准气体测试。
MH-Z19红外二氧化碳传感器
表3 管脚说明 Vin 电压输入 GND Vout (3.3V 电源输出,输出电流 小于 10mA) PWM HD (校零,低电平 7 秒以上有效) UART(RXD) UART(TXD) 0~3.3 V 数据输入 0~3.3 V 数据输出
SR (工厂预留) AOT(工厂预留)
图 2: 管脚定义图
应用电路
命令列表 0x86 0x87 0x88 表5
读气体浓度值 校准传感器 零点 (ZERO) 校准传感器 跨度点 (SPAN)
读气体浓度值
发送命令 Byte0 起始字节 0xFF 传感器返回值 传感器返回(例) Byte0 起始字节 0xFF Byte1 命令 0x86 Byte2 浓度值高位 0x02 Byte3 浓度值低位 0x60 Byte4 0x47 Byte5 0x00 Byte6 0x00 Byte7 0x00 Byte8 校验值 0xD1 Byte1 传感器编号 0x01 Byte2 命令 0x86 Byte3 0x00 Byte4 0x00 Byte5 0x00 Byte6 0x00 Byte7 0x0二氧化碳气体传感器
产品描述 MH-Z19 二氧化碳气体传感器(以下简称传感器)是 一个通用型、小型传感器,利用非色散红外(NDIR)原理 对空气中存在的CO2 进行探测,具有很好的选择性,无氧 气依赖性,寿命长。内置温度补偿;同时具有数字输出与 波形输出,方便使用。该传感器是将成熟的红外吸收气体 检测技术与精密光路设计、精良电路设计紧密结合而制作 出的高性能传感器。 传感器特点 高灵敏度、高分辨率、低功耗 提供UART、PWM波形等多种输出方式 温度补偿,卓越的线性输出 优异的稳定性 使用寿命长 抗水汽干扰、不中毒 主要应用 可广泛应用于暖通制冷与室内空气质量监控。 技术指标 产品型号 检测气体 工作电压 平均电流 接口电平 测量范围 输出信号 预热时间 响应时间 工作温度 工作湿度 外形尺寸 重 寿 量 命 表1 MH-Z19 二氧化碳 3.6~5.5 V DC < 18 mA 3.3 V 0~0.5% Vol 范围内可选 (详见表 2) UART PWM 3 min T90 < 60 s 0~50 ℃ 0~95% RH (无凝结) 33 mm×20 mm×9 mm(L×W×H) 21 g > 5年
昆仑海岸JQAW-8系列二氧化碳传感器
工作日:9:00~17:00
JQAW-8 系列二氧化碳变送器使用说明书
V4.1
主菜单
按 键选择子菜单 按[Enter]确认进入子菜单 按[menu]退出菜单设置,返回到默认显示界面。
密码设置
零点修正
请输入密码
请输入新密码
按 键 修改数 值, 按 键 移位, 按[Enter]键 保存 设置 按[menu]键 返回
JQAW-8 系列二氧化碳变送器使用说明书
V4.1
接线
1.无测试线(在壳体两端有两个开盖键(如下图 ),按下即可打开变送器,内部电路板标识 ):
供电、模拟、网络输出
V+(电源正) OUT(二氧化碳电流或电压输出) GND(电源地) TA(485A+/232RX)(没有选择无用) RB(485B-/232TX)(没有选择无用)
率,数据位,停止位校验方式,采集周期,流量控制 产品出厂默认为:com1,9600,8,1,n,1000,无)。 3、如不是上述原因,请与厂家联系。
北京昆仑海岸传感技术有限公司 电话:010-82671108 传真:010-62533666 售后服务电话:010-51659145 工作日:9:00~17:00
按[menu]键 返回
通讯地址:
报警点设置:上限、上
范围 1-247
上限 100ppm 为一段。
波特率:1200,2400,
设置范围不能超出量
4800,9600,19200,
程。
38400,57600
回差:50ppm 为一段,
范围 50-500ppm
北京昆仑海岸传感技术有限公司
电话:010-82671108 传真:010-62533666 售后服务电话:010-51659145
co2传感器校准标准
co2传感器校准标准1、标定校准人员必须经过培训,了解仪器的原理和性能,熟练掌握操作技能,持证上岗证。
2、调校人员要严格按照操作规程进行操作。
3、使用的仪器必须经过计量鉴定合格后方可使用。
4、标校仪器前先进行外观检查,仪器外观完好后方可调校。
5、标校的仪器先预热20分钟左右,在新鲜空气中对仪器调零。
零点调好后,按仪器规定的流量通入浓度为1.0%左右的标准气样,对仪器显示值进行标校与标准气体值相符合稳定后即可。
二氧化碳传感器校准二氧化碳传感器校准有三种方法:1、用显示控制板;2、用通讯命令;3、如果使用模块的模拟电压输出,可以只在上位机校准。
说明如下:1)用显示控制板校准长按K6, 校准下限。
长按K5,校准上限。
校准将前应先设定标定点。
2) 用通讯命令校准校准下限,命令代码E1。
校准上限,命令代码E2。
此处详细内容可参考通讯协议,同时通过上位机软件的“当前命令”功能,可以查看所有的命令。
如果是测量二氧化碳气体的模块,用空气标定时,应使用命令代码E3。
此命令标定点0.05%Vol。
如果使用模块的模拟电压输出,可以只在上位机程序中校准二氧化碳分析仪日常注意事项很多用户都不知道二氧化碳分析仪日常的注意事项及保养方法,因此不仅影响了数据,而且还影响了仪器的使用寿命:a)仪表应定时保养维护,切勿摔碰,切勿让仪表吸入粉尘。
故障现象原由分析排除方法备注工作时间不足。
充电不足或电池已到使用寿命。
检查充电架使充电架触点接触良好,或更换电池。
b)检修时不得改变原电路中元件的型号、规格及参数等,不得改变原封装。
所有维修必须由专业人员在井上进行。
用户如无法维修可返厂维修或更换。
报警无声接触不良,或电路故障。
检查焊点、导线和电路。
数码管缺划或不亮数码管坏或焊接松动。
更换数码管或补焊。
c) 长时间不使用仪表时应关闭仪表电源,小心贮存,避免长时间强烈日光直射或潮湿的环境。
当二氧化碳分析仪测量误差过大处理方法:1、开机或调零时处于含有CO2气体的环境中;2、报警仪电量不足;3、报警仪漂移;注意:二氧化碳仪表保养与维护应定期对报警仪进行调校和维护,其调校周期不得大于15天。
co2传感器二氧化碳变送器说明书
CH系列CO2传感器说明书产品描述:CH系列CO2传感器测量原理是基于不同气体对特定波段的红外光具有不同的吸收能力,通过测量红外光被吸收的程度来测量被测气体的浓度。
相比传统的电化学和其他传感器具有寿命长,精度高长期稳定性好的优点。
产品主要适合空气中二氧化碳浓度的实时监测。
广泛应用于室内空气质量检测,通风控制系统,楼宇,医院,学校二氧化碳气体监测,空调,空气净化器,蘑菇房,壁炉二氧化碳气体控制。
主要技术指标:检测原理:非色散红外二氧化碳传感器 (NDIR)检测量程:0 ~ 3000ppm 或者 0 ~ 5000ppm 最大0 ~ 100%(订货前选择)使用寿命:10年以上精度:±2% ppm (0~3000ppm) @10 ~ 50℃响应时间:0 ~ 80% < 30sec数据更新:2秒预热时间: @25℃< 90sec①工作环境:0 ~ 50℃, 0 ~ 95%RH Non Condensing贮存环境:-20℃ ~ 70℃输出:模拟输出:4-20Ma, 0-10V,0-5v, ②数字输出: RS485输入电压:DC12V ~ 24V Input (recommend 12V)消耗电流:Peak 150mA, Low 25mA (@12VDC)注:①预热时间内输出的数据为0ppm,传感器有一个自检过程。
②模拟信号对应传感器的量程为线性信号。
接线定义及外壳尺寸:1.接线定义2.外壳安装尺寸所安装的位置应固定安装在墙壁和柱子上距离地面1.5米左右为宜。
具体视情况而定。
顶视图侧视图产品选型表:CH-100是单光束红外二氧化碳传感器;CH-200是双光束红外二氧化碳传感器。
使用环境湿度大温度高的潮湿环境,如果空气中二氧化碳缓慢增加,可以使用CH-200P防护型二氧化碳传感器。
型号量程工作电压工作温度说明CH-100-2K 2k,5k,10K 12-24v 0-50℃室内型商用壁挂CH-200 2k,5k,10K 12-24v 0-50℃室内型商用壁挂CH-200P 2k,5k,10K 12-24v -5-50℃室内型农业用CH-200I 2k,5k,10K 12-24v 0-50℃室内型工业用。
SM5972 微型红外 CO2 传感器 说明书
SM5972微型红外传感器说明书SM5972是世界上最小的CO2传感器模块,可以集成到小型所需的应用程序。
可用于室内空气质量、暖通空调、炉灶、空调、车辆、燃气设备以及建筑通风设备。
SM5972具有精度高,尺寸小,稳定性高等特色。
主要功能及特点非色散红外(NDIR)技术用于测量CO₂水平。
世界最小尺寸预校准提供输出信号成比例的CO₂水平。
可用输出:PWM,TTL UART,报警提供模型与其他设备进行交互。
镀金传感器提供长期校准稳定性。
技术参数接口说明引脚标号说明1 VCC +5V2 GND No use3 UART-RX No use4 PWM (Pulse Width Modulation)5 UART-TX6 AlarmPWM 使用说明每个脉冲都是按如下格式进行的:2 ms 高电平: Start1,000 ms :ppm2ms 低电平: Stop*计算过程:PPM=(tH-2ms) x (Range/1000)* tH : High Pulse Width* 测量范围: 400~2,000/3,000/5,000/10,000 ppm and 400~30,000/50,000 ppm 可选)PWM 输出图示传感器供电影响为了保证传感器正常工作,工作电压保持在4.5V~5.5V DC范围中,超出此电压范围将会导致故障指示,或传感器将不能正常工作。
通讯协议UART 描述38,400BPS, 8bit, No parity, 1 stop bit.TTL Level Voltage (for inspection use)EX) 比如:1,255 ppm, 0x20 0x31 0x32 0x35 0x35 0x20 0x70 0x70 0x6D 0x0D 0x0A ‘1,255 ppm<CR><LF>’重新校准方式1.自动重新校准方法(ACDL)2天在第一,1周定期校正设置为默认值。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
二氧化碳CO2传感器参数
二氧化碳CO2传感器参数特点:
★整机体积小,重量轻
★高精度,高分辨率,响应迅速快.
★上、下限报警值可任意设定,自带零点和目标点校准功能,内置温度补偿,维护方便.
★数据恢复功能,免去误操作引起的后顾之忧.
★外壳采用特殊材质及工艺,不易磨损,易清洁,长时间使用光亮如新.
二氧化碳CO2传感器参数技术参数:
★进口电化学传感器具有良好的抗干扰性能,使用寿命长达3年;
★采用先进微处理器技术,响应速度快,测量精度高,稳定性和重复性好;
★全量程范围温度数字自动跟踪补偿,保证测量准确性;
★半导体纳米工艺超低功耗32位微处量器;
★全软件自动校准,传感器多达6级目标点校准功能,保证测量的准确性和线性,并且具有数据恢复功能;★防高浓度气体冲击的自动保护功能
二氧化碳CO2
传感器参数结构图:
二氧化碳CO2传感器参数接线示意图
:
二氧化碳CO2气体传感器参数
工作电压DC5V±1%/DC24±1%波特率9600
测量气体二氧化碳CO2气体检测原理电化学
采样精度±2%F.S响应时间<30S
重复性±1%F.S工作湿度10-95%RH,(无冷凝)工作温度-30~50℃长期漂移≤±1%(F.S/年)存储温度-40~70℃预热时间30S
工作电流≤50mA工作气压86kpa-106kpa
安装方式7脚拔插式质保期1年
输出接口7pIN外壳材质铝合金
使用寿命2年外型尺寸
(引脚除外)33.5X31 21.5X31
测量范围详见选型表
输出信号TTL(标配)0.4-2.0VDC(常规)/4-20mA 数字信号格式数据位:8;停止位:1;校验位:无;
传感器PIN脚定义图:
传感器应用场所:
医药科研、学校科研、制药生产车间、烟草公司、环境检测、楼宇建设、消防报警、污水处理、石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、锅炉房、加气站、垃圾处理厂、隧道施工、输油管道、工业气体过程控制、室内空气质量检测、地下燃气管道检修、危险场所安全防护、设备检测等。