第八章 热量传递的基本方式

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

第八章 热量传递的基本方式

英文习题

1. Heating of a copper ball

A 10-cm-diameter copper is to be heated from 100℃ to an average temperature of 150℃ in 30 minutes. Taking the average density and specific heat of copper in this temperature range to be ρ=8950 kg/m 3 and C p =0.395 kJ/kg.℃, respectively. Determine (a) the total amount of heat transfer to the copper ball; (b) the average rate of heat transfer to the ball; (c) the average heat flux.

2. Heating of water in an electric teapot

teapot

1.2 kg of liquid water initially at 15℃ to be heated to 95℃ in a

equipped with a 1200 W electric heating element

inside(Figure.8-2).The teapot is 0.5 kg and has an average specific heat of 0.7

kJ/kg.℃. Taking the specific heat of water to be 4.18 kJ/kg.℃ and disregarding any heat loss from the teapot, determine how long it

will take for the water to be heated. 3. Heat loss from heating ducts in a basement

A 5-m-long section of an air heating system of a house passes through an unheated space in the basement (Fig.8-2). The cross-section of the rectangular duct of the heating system is 20 cm×25 cm. Hot air enters the duct at 100 kPa and 60℃ at an average velocity of 5m/s. The temperature of the air in the duct drops to 54℃ as a result of heat loss to the cool space in the basement. Determine the rate of heat loss from the air in the duct to the basement under

steady conditions. Also, determine the cost of this heat loss per hour

if the house is heated by a natural gas furnace that has an

efficiency of 80 percent, and the cost of the natural gas in that

area is

$0.60/therm (1therm=105.500 kJ). 4. The cost of heat loss through the roof

The roof of an electrically heated home is 6 m long, 8 m wide, and 0.25 m thick, and is made of a flat (Fig. 8-3). layer of concrete whose thermal conductivity is λ=0.8 W/m.℃

On a certain winter night, the temperature of the inner and

the outer surfaces of the roof are measured to be about 15℃ and 4℃,

respectively, for a period of 10 hours. Determine (a) the rate

of heat loss through the roof that night and (b) the cost of that heat

loss to the home owner if the cost of electricity is $0.08./kWh.

5. Measuring the thermal conductivity of a

material

A common way of measuring the thermal conductivity of a material is to sandwich an electric thermofoil heater between two identical samples of the material, as shown in Fig. 8-4. The thickness of the resistance heater, including its cover, which is made of thin silicon rubber, is usually less than 0.5mm. A circulating fluid such as tap water keeps the exposed ends of the samples at constant temperature. The lateral surfaces of the samples are well insulated to ensure that heat transfer through the samples is one-dimensional. Two thermocouples are embedded into each sample some distance L apart, and a differential ther mometer reads the temperature drop ΔT across this distance along each sample. When

FIGURE 8-1

FIGURE 8-2