流量检测装置说明书

流量检测装置说明书
流量检测装置说明书

流量检测装置设计说明书

一、装置需求:

1. 100点流量差压信号的采集。用键盘输入流量系数,输入时可显示;

2.范围0-1000l/min,采集周期0.5s,信号4-20mA,分辨力0.1%;

3.要求运用数字滤波(方法自选);

4.计算瞬时流量(l/min)、累计流量(m3/h),并显示;

5.操作人员可随时修改流量系数和切换显示内容(瞬时/累计流量)。

二、设计说明书要求:

1.系统构成框图及构成说明,包括主要部件的选型及依据;

2.DSP与A/D转换芯片连接的电原理图;

3.程序框图,包括主要流程;

4.采集、数字滤波、流量计算程序清单。

三、差压式流量计基本理论

1.节流装置工作原理

差压式流量计是根据伯努力方程和流体连续性原理用差压法测量流量的,其节流装置工作原理如图1所示,在横截面H处:流体的平均流速是v

1

,密度是ρ

1,横截面积是A

1

;在横截面L处:流体的平均流速是v

2

,密度是ρ

2

,横截面积

是A

2

图1 差压流量计工作原理图

根据流体流动连续性原理有如下关系式:

v1·A1·ρ1=v2·A2·ρ 2 (1)如果流体是液体,可认为在收缩前、后其密度不变:

ρ1=ρ2=ρ(2)根据瞬时流量的定义,即单位时间内流体流经管道或明渠某横截面的数量,

所以液体的体积瞬时流量:

2211A v A v q v ?=?= (3)

根据伯努利方程(能量守恒定律),在水平管道上Z1=Z2,则有如下关系式:

2

2

2

2

222

111v P v P ρρ+

=+

(4)

应用伯努利方程和流动连续性原理,在两个横截面上压力差则有如下关系式:

)(2

212

221v v P P P -=

-=?ρ

(5)

将(3)代入(5)式,并整理,则得:

2221

2])(

1[2

v A A P -=

(6)

由于4

2

1D A ?=

π, 4

2

2d A ?=

π, 定义直径比D

d

=

β, 其中d 为工作状况下节流件的等效开孔直径,D 为管道直径,则得到:

222

4

)1(2A q P v βρ

-=? (7)

这样可推导出以下的理论流量公式:

1

2

4

24

11ρπ

β

P

d q v ??-=

(8)

又由于流量系数C 的定义是:C= 实际流量/理论流量,可得出节流式差压流

量计普遍适用的测量体积流量的实际流量公式:

ρ

π

β

εP

d C q v ??-?=

24

12

4

(9)

其中,ε为被测介质的可膨胀性系数:对于液体=1; 对气体、蒸气等可压缩流体<1 。

根据累计流量的定义,即在某一段时间内流过某横截面流体的总量,所以液体的体积累计流量为:

dt q Q t

v v ?= (10)

因此,我们只要检测出差压即可分别计算出瞬时流量和累计流量的大小。

2. 差压变送器工作原理

在采用差压方式进行流量测量时,其流量

v

Q 与差压P ?呈非线性关系,即差

压信号与流量之间存在一个开方关系。为了线性的表达流量,需要对测量系统总

的流量信号进行一次开放运算,具体如下:

输入起始值

输入满程值输入起始值

输入值输出起始值输出满程值输出起始值输出值--=

-- (11) 即:

输出起始值

输出起始值输出满程值输入起始值

输入满程值输入起始值

输入值输出值+-?--=)(

应用实例:

求测量范围为0-4KPa ,输出4-20mA 的带开方差压变送器,输入2KPa 差压值时的输出电流为多少?

输入2KPa 时的输出电流=

31.154165.04)420(0

40

2=+?=+-?--mA 四、差压式流量计硬件设计

差压式流量计整体设计框图如图2所示, 首先安装在管道中的多个节流装置检测出流体差压

j

P ?,送入差压变送器转换为相应电流

j

I (4-20mA );然后

DSP 控制多路模拟开关选择输出一路电流

j

I 到放大器,使其转化为相应电压

j

U (0-5V );最后信号由A/D 采样后导入到DSP (同时选通第二路电流信号),对多路数据进行处理并显示。

节流装置

差压变送器

多路模拟开关

节流装置差压变送器

节流装置

差压变送器

……

……

……

……

放大器

A/D DSP

显示

键盘

图2 差压式流量计整体设计框图

1. 节流装置的选型

根据装置需求 100点流量差压信号的采集,范围0-1000l/min ,本设计选用MPA (Multi-Point Averaging Flow meter )流量计(多点测量平均流速流量计)。每个MPA 流量计有24点流量信号的采集,相比其他只能2点流量信号采集结构的流量计而言,精度高;同时流量范围1-15000(m3/h )远超过设计指标要求。

MPA 流量计是一种用于测量管道中液体,气体或蒸汽等流体流量的新型的差压式流量计。流体的流量正比于流量计差压信号的平方根,用户只需配用差压计及流量显示积算仪就可以得到准确的流量测量。

(1)与一般的速度式流量计的区别 :

例如:皮托管流量计-测量的是某个点的流速;均速管流量计-测量的是管道纵向或横向分布的平均流速。而MPA 流量计是测量分布在管道截面上多个点(测量点是严格按切比雪夫积分法选取在管道横截面上)的流体流速并最终得到准确的管道平均流速测量,因此它具有良好的流量测量准确度; (2)与一般节流式差压流量计的区别:

与节流式孔板流量计、v 型内锥式流量计等相比。MPA 流量计的管道压力损失很小,仅为普通孔板流量计的1/5--1/8,是一种节能式流量测量仪表;

由于测量是通过管道截面多点平均流速的测量来实现的,因此MPA 流量计对前直管段要求相对较低,一般表前有5倍D 的直管段就可以满足测量要求,而表后只要有2倍D 的直管段就可以满足要求;

场取压差压测量技术措施可抑制测量噪声,提高信号测量的准确性,测量范围度一般可达到1:12或更大。

MPA 流量计的结构如图3所示。

图3 MPA 流量计的结构图

用MPA 流量计测量流量的关键是如何确定特征点(即流速测量点的分布)。目前比较常用的有等环面法、切比雪夫积分法和对数线性法。

等环面法将半径为R 的圆管分成n 个面积相等的同心圆环(最中间的为圆)。在每一个圆环的等面积处设置测量点,即特征点位置。半径方向上n 个测量点的

位置为r1、r2、r3……、rn ,

n i R

r i 21

2-=。

切比雪夫积分法是利用切比雪夫插值点ti 求函数在区间﹣1到1的积分的一

种近似算法。经过变换,可以求得管内半径方向的测点位置

i

i t R

r 2121+=。

对数线性法选择特征点的原则是把各环面上的平均速度看作是该环面上各特征点所测得的速度的算术平均值。而整个截面上的平均速度就等于各环面平均速度的算术平均值。

MPA流量计是严格按照切比雪夫法选取分布在管道上的流速测量点的,其分布图如图4如下:

图4 流速测量点分布示意图

MPA流量计为低压差设计,因此测量气体时一般不必考虑气体膨胀系数的影响。只有在低压系统中使用(例如常压系统气体流量测量),差压值与系统压力比(△p/P)大于4%时需要考虑气体膨胀性对测量的影响。

因此,MPA流量计是一种新型的高性能的流量测量仪表。其参数指标如下:

2. 差压变送器的选型

根据装置需求输出电流4-20mA,另外考虑到测量范围、精度等级及工作温度等多种因素,本设计选择ZL1151电容式差压变送器。ZL1151输出电流4-20(mA),测量范围0-40000(KPa),精度等级0.05%,工作温度-40-140摄氏度,优于装置需求。ZL1151电容式差压变送器结构图如图5所示。

图5 差压变送器结构图

产品特点:

●超级的测量性能,用于压力、差压、液位、流量测量;

●精度高:数字精度+(-)0.05%;模拟精度+(-)0.5%~+(-)0.1%F.S;

●量程、零点外部连续可调,量程比100:1;

●正迁移可达500%、负迁移可达600%;

●稳定性能好,稳定性:0.25% 60个月;

●耐过压;

●固体传感器设计;

●全系列统一结构、互换性强;

●接触介质的膜片材料可选;

●低压浇铸铝合金壳体;

●测量速率:0.2S;

●小型化(2.4kg)全不锈钢法兰,易于安装;

●过程连接与其它产品兼容,实现最佳测量;

●采用16位计算机的智能变送器;

●标准4-20mA,带有基于HART协议的数字信号,远程操控;

●支持向现场总线与基于现场控制的技术的升级;

ZL1151电容式差压变送器关键技术指标如下:

3.多路模拟开关的选型

考虑到100点差压信号的采集需要100路模拟开关控制,因此本设计选用13片AD7501芯片,通过DSP发出控制信号选择某一路差压信号输入。其逻辑结构及引脚如图6所示,3个地址线A1、A2、A3,1个使能端EN,8路输入S1、S2-----S8,1路输出Out。

图6 AD7501逻辑结构及引脚图

AD7501性能指标如下:

●CMOS工艺制造;

●单8路1模拟多路转换器;

●16引脚DIP封装;

●电源:+/-15V;

●功耗:300uW;

●开关接通电阻:170欧;

●开关接通、断开时间:0.8us;

4. 放大电路

由于差压变送器的输出信号为电流值,且幅值较小达不到ADC需要的采样幅值,所以信号首先要经过放大器的放大处理,转化为0-5V的电压信号,如图7所示,发射信号经一对二极管IN4007的幅值保护后由同相放大器LF357与反相放大器LM318完成信号的放大处理。

图7 放大电路

5. A/D转换器的选型

根据装置需求分辨力0.1%,(分辨力是指仪表能显示的最小数字(零除外)与最大数字的百分比),以及采集周期0.5s,所以本设计选用美国AD公司新近推出的一种性能优越、由BMIOS工艺制成的12位模数转换芯片ADl674。本芯片采用12位逐次比较方式工作,除了具有较高分辨力0. 05%外,采样频率高达100 kHz,即转换速率达10μs,片内还集成有高精度的基准电压源与时钟电路,从而使芯片在不需要任何外加电路和时钟信号的情况下完成A/D转换,使用非常方便。

AD1674 的基本特点和参数如下:

●带有内部采样保持的完全12 位逐次逼近(SAR)型模/数转换器;

●采样频率为100kHz;

●转换时间为10μs;

●具有±1/2LSB 的积分非线性(INL)以及12 位无漏码的差分非线性(DNL);

●满量程校准误差为0.125%;

●内有+10V 基准电源,也可使用外部基准源;

●四种单极或双极电压输入范围分别为±5V,±10V,0V~10V 和0V~20V;

●数据可并行输出,采用8/12 位可选微处理器总线接口;

ADl674的内部结构及引脚排列如图8所示。各引脚的符号、类型及意义请参考有关资料手册。

图8 ADl674的内部结构及引脚排列

6.DSP芯片的选型

根据装置需求对100点差压数据采集,周期0.5秒,数据量较大,对速度有较高要求,同时对精度上要求10位以上,所以本设计选用TMS320C5402定点dsp 处理器。TMS320VC5402是C54x系列的杰出代表,是一款性价比极高的定点DSP,具有速度快(指令周期为10ns ),精度高(32位),192K bytes的存储空间(64K bytes的程序存储空间、64K bytes的数据存储空间、64K bytes的I/O空间),功耗低,价格便宜的特点。C54x采用多总线技术,具有一条程序总线、3条数据总线和4条地址总线,可同时进行程序指令和数据的存取,具有高度的并行性。C54x采用模块化的设计,使派生器件得到了快速的发展,并且采用了最新的芯片制造工艺,提高了芯片的性能,降低了功耗。

TMS320C5402基本特点:

●运算速度快,指令周期为10ns;

●192K bytes的存储空间(64K bytes的程序存储空间、64K bytes的数据存储空间、64K bytes的I/O空间);

●优化的CPU结构。1个40位的算术逻辑单元、2个40位的累加器、2个40位的加法器、1个17×17乘法器和40位的桶型移位器,有4条内部总线和2个地址产生器;

●低功耗,可在3.3V或2.7V电压下工作,三个低功耗方式;

●智能外设,除标准的串行口和时分复用串行口外,还含有自动缓存串行口(2k buffer)和外部处理器并行口HPI。

TMS320C5402的结构如图9所示。各引脚的符号、类型及意义请参考有关资料手册。

图9 TMS320C5402的结构图

7. DSP与A/D转换芯片的接口设计

ADl674有2种工作方式:独立工作方式和完全受控方式。独立工作方式不需使用全部控制信号,具有专用输入端口,启动转换要比完全受控方式精确;完全受控方式要使用全部控制信号,适用于多个需寻址电路挂在同一总线的情况,接口电路对各种控制信号的时序要求严格,因此设计要复杂些.考虑到本系统有多个寻址电路,故采用完全受控方式。完全受控方式下ADl674启动和读数时序如图10所示。

图10 ADl674启动和读数时序图

当要启动AD转换时,只需向ADC写一任意数据即可,此时CE变高,而CS变低,R /C=0,AD1674启动转换。转换结束后STS发出中断请求信号,在中断服务程序中读转换结果,此时,CE变高,同时R /C=1,而CS为低,DSP 通过数据线从总线驱芯片74ACT16245读取AD1674转换数据。从完全受控方式的工作时序图可以看出,无论是进行AD转换还是进行读取数据,为了使AD1674能可靠地工作,CE信号需落后R /C信号约50ns。

完全受控工作方式下AD1674与TMS320C5402的接口电路图如图11所示。

图11 AD1674与TMS320C5402的接口电路图

五、差压式流量计软件设计

设计思想:

(1)首先向DSP发出输入流量系数的中断请求,然后通过矩阵键盘输入流量系数并由LED显示;

(2)DSP向多路模拟开关发出控制命令,使100点差压信号在1min内,以0.5s 的数据采集周期以次顺序通过A/D采样、数字滤波、流量计算,(其中每min 瞬时流量为每路差压信号即刻测定流量值,每h累计流量为60min的瞬时流量累加和),最后存储在分配好的数据空间待读出显示;

(3)向DSP发出某一路瞬时流量/累计流量中断请求,DSP响应中断并从数据存储空间取出流量数据进行显示。

1. 软件设计流程图

开始

中断设置

开中断

是否发生中断

数据采集结束调用中断子程序

N

Y

数字滤波

流量计算

总程序流程图

中断子程序开始(INT1)

保护现场

流量系数显示

(C)

恢复现场

结束

中断子程序开始

(INT2)

保护现场

瞬时流量显示

(l/min)

恢复现场

结束

中断子程序开始

(INT3)

保护现场

累计流量显示

(m3/h)

恢复现场

结束

中断流程图

开始

定时/计数器初始化

t=0,i=1

片选多路模拟开关输入

电流I j

启动A/D 转换

A/D 并行输出至DSP

数字滤波

转换结束STS==0?

计数器i<=100?

启动定时/计数器

定时器t<=0.5s?

等待while(1)

Y

N

Y

N

流量计算

N

Y

数据采集及处理流程图

开始

设置HD0行为低电平

HD4-HD7列是否为低电平?

设置HD1行为低电平

HD4-HD7列是否为低电平?

设置HD2行为低电平

调用显示子程序

调用显示子程序

HD4-HD7列是否为低电平?

设置HD3行为低电平

调用显示子程序

HD4-HD7列是否为低电平?

LED 显示

调用显示子程序

Y

N

Y

Y

Y

N

N

N

矩阵键盘流程图

开始

设置显示数码管个数

设置译码模式

设置LED亮度

设置LED工作状态

串行装入显示数据

N

串行驱动LED显示

LED显示完?

Y

结束

LED显示流程图

2.程序设计

(1)数据采集

void main()

{

in it_5402();

while(1)

{

start_ad1674();

while( ((*(volatile u16*)IFR)&0x0001) ) {};

}

}

void in it_5402(void)//初始化VC5402时钟和CPU

*(volatile u16*)CLKMD=0x0000;

while(*(volatile u16*)CLKMD&0x0001){};

*(volatile u16*)CLKMD=0x9807;

*(volatile u16*)PMST=0x00A0;

*(volatile u16*)SWWSR=0x7fff;

*(volatile u16*)SWCR=0x0001;

*(volatile u16*)BSCR=0x8802;

*(volatile u16*)IMR=0x0001;

}

void start_ad1674(void)

{

port2=0x10;//向ADC写任何数启动转换

}

(2)数字滤波

FIR数字滤波器的结构

设h(n),n=0,1,2…N-1为滤波器的冲激响应,输入信号为x(n),则FIR滤波器就是要实现下列差分方程:

∑-=-

=

1

) (

)(

)

(

N

i

i

n

x

i

h

n

y (12)

式中,y(n)为输出信号,即经过滤波之后的信号;N为滤波器阶数。FIR滤波器的最主要特点是没有反馈回路,因此是无条件稳定系统,其单位脉冲响应h(n)是一个有限长序列。由式(1)可见,FIR滤波算法实际上是一种乘法累加运算,不断地输入样本x(n),经延时(z-1)做乘法累加,再输出滤波结果y(n)。对式(1)进行Z变换,整理后可得FIR滤波器的传递函数为:

∑-=-

=

1

0)(

)

(

N

i

i

z i

h

z

H (13) FIR滤波器的一般结构如图12所示。

图12 FIR滤波器结构

FIR低通滤波程序

char filter()

int i,n;

int sum, y[];

for(n=0;n<=255;n++)

{

sum=0;

for(i=0;i<=16;i++)

{

sum+=h[i]*x[n+16-i]/32768;

y[n]=sum;

}

}

return (char)(y[n]);

}

(3)流量计算

累计流量程序

#define M 60

char accumulated_flow ()

{

int sum2 = 0;

for ( count2=0;count2

sum2 + = instantaneous_flow (); delay();

}

return (char)(sum2);

}

采集终端检测装置说明书

大用户用电信息采集终端 检测装置 使用说明书

郑州三晖电气股份有限公司 目录 1、概述 (3) 、说明 (3) 、系统组成 (3) 、产品特点 (3) 2、参考规程 (6) 3、技术指标 (7) 输出电压 (7) 输出电流 (7) 相位及对称度 (7) 输出频率 (7) 功率稳定度 (7) 4、结构组成 (8) 5、计算机软件 (9) 6、服务保证 (10) 注意事项 (10) 服务保证 (10) 联系方式 (10)

1 概述 说明 大用户用电信息采集终端检测装置(简称:检测装置)是郑州三晖电气股份有限公司研制的技术领先的用电信息采集终端检测装置,它是根据国家电网公司企业标准《Q/GDW129-2005 电力负荷管理系统通用技术条件》、《Q/GDW130-2005 电力负荷管理系统数据传输规约》、《Q/GDW373~380电力用户用电信息采集系统》、《DL/T698-2010电能信息采集与管理系统》等技术规范研制开发的测试装置,可广泛应用于对采集终端的性能测试、评估,是电力部门对终端验收的有利保障。它美观实用,可靠性高、测量准确度高、长期稳定性好、自动化程度高、测试功能齐全。 该产品同时集成计量校验和功能校验两大系统,主要实现集中器、采集器和三相电能表的现场抄表。采集终端检测装置由:程控测试电源、标准电能表、总控中心、功能测试单元、误差计算器、挂表架、二次故障模拟板、网络交换机、铝合金台体、控制计算机等部分组成。通过计算机控制能够自动完成全部的检定项目,并且能够提供完整的自动校表、功能测试、误差数据处理、存储、查询、证书打印、报表输出等整套解决方案。 系统组成 大用户采集终端检测装置部分包括96个三相电能表,2个集中器。每块采集器可以带抄读12块三相电能表的电量数据。大用户采集终端检测装置共包括2个台体,每个台体分为8排,每排12表位,背靠背放置; 程控电源:其主要功能是给采集终端提供电压和电流,电压和电流的相位、幅值、频率是可调,可以让终端或电能表产生各种状态。 标准电能表:它用于检测电压和电流,并显示电压、电流的全部电参量。 总控中心:它通过网线与计算机相连接,实现总体控制整个装置。

流量检测仪使用说明书

Flo-Tech, PFM6 流量压力检测仪使用说明书

流量压力检测仪的使用要领1. 检测仪各部名称(图1) 涡轮流量计各部名称(图2)

2. Flo-tech检测仪参数 * 为现用检测仪 (1) 检测仪使用要点 本检测仪操作简单,不需要特殊练习,就可以立刻使用。为了正确的判断试验结果,有必要事先了解测试对象的液压系统和各液压执行部件,掌握必要的资料,比如:操作压力、流量、溢流阀设定压力、液压泵的最高输出压力、液压泵的性能曲线等。 ①液压软管的连接 检测仪如上表所示有三种机型,其软管的连接分两种类型 a、PFM6-50、PFM6-85为1英寸的PT内螺纹。 b、PFM6-200上附有1英寸PT螺纹的连接器。 90°的管接头、T型管接头、阀等距离检测仪的输入端最好在30cm以上,因为这些部件将会给流体的测量带来误差。软管的另一侧(与被测机器连接侧)通常与连接检测仪一侧为相同连接螺母,所以当管径或螺纹不同时,请利用转接器。 ②操作要领 检测仪的操作是简单的,但误操作将会给检测仪或被测试机器、回路带来不良影响。 使用者在使用前请读熟本使用说明书,避免误操作,以提高测试效率。 a、转换开关通常在中央位置(OFF) 测试流量时请放在(FLOW)档位 测试油温时请放在(TEMP)档位 测试结束后,请勿必将开关拨回到OFF位置。

干电池使用过期电压下降时,仪表(流量、温度计上的冒号:)将发生闪烁。此时,请更换干电池。 b、认真确认软管是否已正确无误地连接在检测仪的输入、输出端。检测仪可以并列接入高 压侧,但流向若是接反则不能测量正确的流量。 c、液压回路动作前,应将加载阀反时针方向旋转打开。 d、加载阀可以用手简单地进行操作,在加压和卸压时,请缓慢地进行操作。 e、液压回路动作停止之前,要将加载阀打开,确认压力是否已降到零。在进行多项压力测 试时,每一次测试结束,也都应该将加载阀先打开,然后进行下一个项目的测试。f、安全圆片是保护检测仪和液压机器的,测试时,请密切注意压力表的读数,使之不要超 过回路的最高压力。尤其是当回路撤离了溢流阀之后,回路中的压力过于升高,将会使液压泵损坏。(参照图4) 当压力超过检测仪最高测试压力的1.5倍时,高压油将冲垮圆盘,向外喷 射油液。 (2) 液压系统试验 ①预备检查 a、被试验机器液压油箱内的油量是否合适。 b、有没有外部泄漏的现象。 c、各部的连接是否确实可靠。 d、有没有已经损伤的零部件。 e、检测仪的5项使用要领是否都已理解。 ②一般的故障及其原因

七星电子流量计 D07-7B_7BM使用手册

D07 - 7B 型质量流量控制器 D07-7BM 型质量流量计使用手册 版本2013.6

目录 1. 使用须知................................... 1 6.2.1 开机预热.. (15) 2. 用途和特点.............................. 1 6.2.2 检查和调整零点 (15) 3. 主要技术指标........................... 3 6.2.3 通气工作 (15) 4. 结构和工作原理........................ 4 6.2.4 关机 (15) 4.1 结构....................................... 4 7. 注意事项 (15) 4.2 工作原理................................. 5 7.1 禁用流量介质 (15) 5. 安装和接线...........................7 7.2 使用腐蚀性气体问题 (15) 5.1 外形及安装尺寸........................7 7.3 阀口密封问题 (16) 5.2 气路接头形式...........................8 7.4 阀控操作注意 (16) 5.3 连接电缆插头...........................9 7.5 安装位置问题 (16) 5.4 与计算机或外部信号的连接.........11 7.6 注意工作压差 (16) 5.5调零和外调零...........................12 7.7 标定和不同气体的换算 (17) 6. 使用方法和操作步骤..................13 7.8 D07-7B,7BM标准订单填写格式 (18) 6.1 质量流量控制器的操作...............13 8. 故障判断和处理 (21) 6.1.1 开机操作..............................13 9. 保证、保修与服务 (23) 6.1.2 清洗功能..............................14 9.1 产品保证和保修.. (23) 6.1.3 显示仪与计算机连接的操作......14 9.2 保修对使用的要求.. (23) 6.1.4 直接与计算机连接的操作.........14 9.3 服务.. (23) 6.1.5 阀控功能..............................15 10. 附录 (24) 6.1.6 关机操作..............................15 10.1气体质量流量转换系数 (24) 6.2 质量流量计的操作...................15 10.2转换系数使用说明 (26) MASS FLOW CONTROLLER & MASS FLOW METER

液位检测实验装置操作说明

KPXJS-LRC系统实训步骤 液位实训装置是自动化及相关专业的教学及实训设备。通过本套实训装置,学生可熟练掌握常用液位仪表及装置的使用、安装、调试校准、维护,熟悉液位仪表控制装置信号回路及信号关系,培养学生液位仪表的专业基础技能,提高学生的实际操作能力,为将来走向工作岗位打下坚实基础。 一、液位检测系统实训装置组成 1-主水箱:试验装置中液体主盛装容器;2-1#水箱:试验装置中液体付盛装容器;3-2#水箱:试验装置中液体付盛装容器;4-3#水箱:试验装置中液体付盛装容器;5-4#水箱:试验装置中液体付盛装容器;6-5#水箱:试验装置中液体付盛装容器;7-电动调节阀:电动执行机构,通过智能数显控制仪来控制它,调节分容器液位的变化;8-玻璃管液位计:可视液位计,直观的显示出各容器的液位; 9-主水泵:实现试验中液体在主与付容器之间的切换,实现试验中液体的流动;10-副水泵:实现试验中液体各付容器之间的切换,实现试验中液体的流动;11-浮筒液位计:1#水箱液位显示;12-静压液位计:2#水箱液位显示;13-雷达液位计:3#水箱液位显示;14-电容液位计:4#水箱液位显示;15-磁翻板液位计:5#水箱液位显示;16-差压变送器:5#水箱液位液位显示,通过球阀Q6、Q7、Q8可以进行差压变送器的零点迁移试验;17-电磁阀:与主副水泵配合,实现液体在各容器间的变化; 18-仪表控制柜:试验所需仪器仪表控制箱;A1-闪光报警器;B1-B5智能数显表:1#-5#水箱液位;C1-智能数显控制仪:

控制调节阀,副操器;C2-智能数显表; C3-智能数显控制仪:控制调节阀,副操器;C4-智能数显表;C5-智能数显表:5#容器液位比较;ST11-15:1#-5#容器上电磁阀控制旋钮;ST16:副水泵液位旋钮;ST21-25:1#-5#容器下电磁阀控制旋钮;T26:主水泵液位旋钮;ST31:A1报警器声音消除按钮;ST32:A1报警器声音试验按钮;ST33:调节阀仪表控制柜与DCS切换旋钮;ST34:备用旋钮; Q1 ——Q9等球阀:通过球阀的开关来实现不同的试验。 二、实训准备步骤 1.仪表柜送电,观察仪表柜电源指示灯,如果不亮,请检查电源 2.将各数显仪表送电,观察数显表和现场仪表,如有异常请检查,排除故障 3.观察主水箱液位,如果主水箱液位低于1/2,请补充液位 4.通过与水箱连通的玻璃管液位计感知容器内的水位与实际数显控制仪显示液位比较,先校验零位和满度使数显控制仪显示零位、满量程 三、液位试验(无调节阀) 1.打开阀门Q1、Q3、Q4、Q5,关闭Q2、Q6 2.操作ST11旋钮,打开1#水箱上电磁阀LV101A,操作ST26旋钮,打开主水泵,开始上水 3.观察主泵出口压力表,观察视窗,观察1#水箱液位 4.通过调节实际水位依次调整满量程的0%、25%、50%、75%、

静电测试仪使用说明书

Hand-held static sensor locates and meas-ures static voltages, tests air ionizers.New from 3M,the 718 Static Sensor can help companies competing in the global high-tech marketplace prevent cost-ly losses due to electro static discharge (ESD) damage by playing a vital and valuable role in their own ESD control program. Easy to use,the hand-held 3M ?718 Static Sensor is designed to measure static voltages on objects and sur-faces arising from electrostatic charge buildups,and can help identify ESD trouble-spots — ensuring product relia-bility and customer satisfaction which translates into com-pany profits. As a bonus,when used in conjunction with the 3M TM Model 718A Air Ionizer Test Kit,the 718 can also be used to verify the operation of air ionizers.718 Static Sensor Features ? Small-size,lightweight,conductive plastic housing ? Membrane switches for Power,Range/Zero,and Hold functions. ? Digital,LCD (liquid-crystal) display is easy to read and updates quickly. ? Ranging system assists user in making quick and easy measurements ? Measurements accurate to 5% ? Output jack available for continuous measurements Convenient Size/Low Power Requirements The 718 is small enough to be carried in a pocket and weighs less than 5 oz. (142 g),including battery. The light-weight plastic housing is conductive,allowing a properly-grounded user to dissipate all electrostatic charges from the surface of the meter.Meter Functions The meter is equipped with three membrane switches which control different functions. The POWER switch turns the instrument on and off. The RANGE/ZERO button performs two functions; when pressed momentarily it switches between the two measurement ranges of 0-2,000 volts and 0-20,000 volts,and if held for longer than 3 seconds,it resets the voltage display to 0 volts. The HOLD button allows the user to freeze a measurement on the LCD for later review.Ranging System Included with the 3M 718 Static Sensor is a ranging system consisting of two light-emitting diodes (LEDs) which each emit a circular red light onto the surface being measured for static. When the two lights intersect and form a single focused light,the measurement distance is the prescribed 1 inch (2.54 cm). Accuracy The Model 718 Static Sensor is accurate to within ±5% of the displayed measurement,at a distance of one inch (2.54 cm) from the target. Accuracy will vary as the dis-tance between measured object and instrument changes from the one inch (2.54 cm) specification.Analog Output Jack The analog output jack located in the front of the unit pro-vides a convenient hook-up,via a 3/32 inch (2.5 mm)monophone jack,to a recorder/data acquisition console. The 3M 718 Static Sensor may then be used for remote monitoring or permanent recording of electrostatic voltage readings. 3M 718 Static Sensor Specifications Dimensions 0.85" (H) x 2.4" (W) x 4.15" (L) 2.2 cm (H) x 6.1 cm (W) x 10.5 cm (L)Weight 4.5 oz. (128 g) with battery Power Requirements One 9-volt alkaline battery Measurement Ranges 0 – 2 kV Low Range 0 - 20 kV High Range V oltage Display 3) digit liquid crystal display V oltage Output 1/1000 of measured voltage @ low range 1/10,000 of measured voltage @ high range Distance Indicator LED targets. Aligned targets indicate 1 in. (2.54 cm) measurement distance Measurement Accuracy Within 5% of actual voltage Certifications UL,C-UL,CE,CB-scheme,NOM 3 718 Static Sensor 718A Air Ionizer Test Kit 718 Range Finder Unfocused 718 Range Finder at 1" away 3M 718 Static Sensor 1 2 3

LWGY涡轮流量计说明书111

LWGY基本型涡轮流量传感器(LWGYA型涡轮流量变送器)(LWGYB型涡轮流量计) (LWGYC型涡轮流量计) 使用说明书

目录 一、概述 02 二、LWGY基本型涡轮流量传感器 02 三、LWGYA型涡轮流量变送器 07 四、LWGYB型涡轮流量计 08 五、LWGYC型涡轮流量计 09 六、LWGYD型涡轮流量计 09 七、维修和常见故障 22 八、运输、贮存 22 九、开箱注意事项 22 十、订货须知 23

一、概述 LWGY系列涡轮流量传感器(以下简称传感器)基于力矩平衡原理,属于速度式流量仪表。传感器具有结构简单、轻巧、精度高、复现性好、反应灵敏,安装维护使用方便等特点。广泛用于石油、化工、冶金、供水、制药、环保等行业。传感器与显示仪表配套使用,适用于测量封闭管道中无腐蚀,无纤维、颗粒等杂质,粘度小于5×10-6m2/s的液体介质。 二、LWGY基本型涡轮流量传感器

1.工作原理 液体介质流经传感器壳体,由于叶轮的叶片与流向形成特定的角度,流体的冲力使叶片具有转动力矩,克服摩擦力矩和流体阻力之后叶片旋转,在力矩平衡后转速稳定,转速与流速成正比,由于叶片有导磁性,它处于信号检测器的磁场中,旋转的叶片切割磁力线,周期性的改变着线圈的磁通量,从而使线圈两端感应出电脉冲信号。信号经过放大器的放大整形,形成有一定幅度的连续的矩形脉冲波,可传输至显示仪表,显示出流体的瞬时流量或总量。在一定流量范围内,脉冲频率f 与流经传感器的流体的瞬时流量Q 成正比,流量方程为: k f Q ? =3600 式中: f ——脉冲频率[Hz]; k ——传感器的仪表系数[1/m 3 ]或[1/L]; Q ——流体的瞬时流量[m 3 /h]或[L/h]; 3600——换算系数; 每台传感器的仪表系数k 略有不同,这是由制造厂

制冷与空调检测实训装置使用说明书

目录 一、概述 (2) 二、技术参数 (2) 三、装置的特点 (2) 四、装置的组成与基本装备说明 (3) 五、装置的启动及运行 (7) 六、故障设置及分析 (8) 七、装置放置环境要求 (9) 八、装置放置空间要求 (13) 九、电源要求 (13) 十、装置的保养与维护 (13)

一、概述 THPKT-1A 型制冷与空调检测实训装置是根据教育部“振兴21世纪职业教育课程改革和教材建设规划”要求,按照职业教育的教学和实训要求研发的产品。适合高职院校、技工学校、职教中心、鉴定站/所制冷类专业的制冷技术、《热泵技术教学》、《家用制冷设备原理与维修》、《制冷空调装置操作安装与维修》、《小型制冷与空调装置》、《制冷空调机器设备》、《空气调节技术与运用》、《冷库制冷工艺》、《制冷空调自动化及机电一体化》、《制冷与低温工程》等的实训教学及相关专业《制冷工中、高级》实训考核。 该智能考核系统装置培养掌握空调与制冷技术专业理论知识和专业实践技能,从事空调、制冷设备及系统的技术升级、改造设计、安装、调试、维护、维修、技术管理等方面的技能应用型人才。 该智能考核装置在实训室管理、考核管理方面更加科学化、更加贴近实际教学,可供学生学习锻炼,通过模拟故障设置,有利于开展技能鉴定、考核工作,是适合高职院校、职业学校制冷技术、热泵技术教学的实训装置,更是制冷与空调设备维修专业技能考核的理想设备。 二、技术参数 1.输入电源:单相三线 AC220V ±10% 50Hz 2.装置容量:<1kVA 3.外形尺寸:1000mm×590mm×1610mm 4.制冷剂类型:R22 5.安全保护:具有漏电流保护装置,安全符合国家标准 三、装置的特点 1.系统采用真实的制冷机组,与实际教学接轨。整个空调系统真实完整,与市场上的遥控分体热泵落地式空调的总体结构、性能完全相同。具有制冷、制热、通风、除湿、温度、风速选择、定时、扫风控制、睡眠、自动、灯光等功能 2.整套实训装置集制冷系统、电气控制系统、故障模拟系统于一体,系统真实完整,结构清晰、紧凑,与实际空调制冷系统、电气系统一致,满足对实训的要求 3.实训装置直观展示了柜式空调的系统结构、工作原理,可清楚的看到制冷循环系统结构及主要部件的实物,系统还配置有交流电压表、交流电流表、温度表、真空压力表、发光二极管使整个空调系统的实时工作状态一目了然;便于教学演示讲解及学生对课本知识的理解掌握。 4.装置设有室外机部件电气控制线路接线区域,可完成对电气连接、压缩机绕组、室外风机绕组判断等,有利于学生将理论应用于实际,并培养学生实际操作动手能力。 5.可模拟故障设置,学生根据故障现象分析故障可能产生的原因,确定故障发生的范围,并进行排故。有利于开展技能鉴定、考核工作

皮托管流量测量装置使用说明书

皮托管流量测量装置安装使用说明书 C M (06)渝制00000331 重庆渝润仪表有限公司

2 一、概述 本公司生产的S 形皮托管主要用于气体流量的测量,特别是如焦炉煤气、高炉煤气、水炉煤气、各种烟气等赃污介质流量的连续测量。 二、性能特点 本公司采用独特并且专业的技术,生产的S 形皮托管流量测量系统的测量精度经过有关部门实流检测,误差为±0.46%,达到0.5级精度;同时,独特设计的感压孔,长期使用不会堵塞。主要有以下特点: ▲长期运行精度高、稳定性好。 ▲无可可动部件与易损部件,使用寿命长。 三、主要技术参数 ▲测量精度: 0.5级 ▲管道覆盖面:100~5000mm 。 四、测量原理 1、 测量系统组成 流量测量系统由皮托管、差压变送器、压力变送器、温度传感器、流量积算控制仪等组成,如图一所示:

3 图一 图一是在线带温度压力补偿的流量测量,如果现场的温度压力参数比较稳定,变化不大,也可以定点设定温度压力补偿方式进行流量测量。 2、流量测量计算公式 流量测量计算公式根据国标GB 5468-91确定,具体如下: 2.1密度的计算 测试工况下湿气体密度γs 按式(1)计算; 式 中: N ——标准状态下湿气体密度,kg /Nm 3 , ts ——测量断面内气体平均温度,℃ Ps ——测量断面内气体静压,Pa ; Ba ——大气压力,Pa 。 2.2 管道内气体流速及流量的计算 气体流速按照式(2)计算: 式中:Vs i ——测定点流速,m /s ; Kp ——皮托管修正系数; γs ——管道内湿气密度,kg /m 3; Pdi ——测定点气体动压,Pa 。 2.3 在测定点工况下气体流量按式(3)计算: Q=3600×F×Vs (3)

检测仪使用说明书

检测仪使用说明书 一.概述 核酸蛋白检测仪、紫外检测仪是液湘色谱仪中的一种紫外检测装置,核酸蛋白检测仪、紫外检测仪是根据生命科学的发展对于现代色谱仪器的要求而改进设计的一种新型紫外检测仪。该仪器在创新方面的主要特点为: 1.该仪器除配有输出10mV记录仪信号外,还配有输出适合计算机积分仪的输口,这 样很方便构成色谱工作站系统。(可同时进行计算机和记录仪信号输出,亦可省去记录仪) 2.该仪器的数字显示设计为固定光吸收,A显示计算机用和可变量程光吸收A显示记 录仪用两种可选模式,这样可方便于规范化读数(特别是可应用于药品生产的GMP 工艺规范化管理),同时亦可根据科研需要进行可变量程的高灵敏度读数,这样可方便于对低浓度样品检测。 3.该仪器采用新型进口IP28光电倍增管和改进型电路结构,使仪器工作更为稳定可 靠。 该仪器配有上层析柱、恒流泵、部分收集器等等,即组成一套完整的液色湘色谱分离分析系统。它可应用于现代生物学研究,药物测定、农业科研、化工、食品及医疗单位对具有紫外吸收的样品作定量分析。本仪器主要元器件均采用进口,仪器全部采用LED数字显示,使用方便。 二.主要技术性能 (1)核酸蛋白检测仪提供波长:254nm、280nm。 (2)紫外检测仪提供波长:220nm、254nm、280nm、340nm。 (3)量程范围:0~100%T、0~2A、0~1A、0~0.5A、0~0.2A、0~0.1A、0~0.05A。 (4)流式样品池:容积100微升、光程3毫米。 微量样品池:容积30微升、光程10毫米。 (5)记录仪输出:10mV (6)积分仪输出:0.1A/mV (7)数显模式:固定A量程读数(0~2.0A);可变A量程读数(0~2.0A、0~1.0A、0~0.5A、0~0.2A、0~0.1A、0~0.05A)。 (8)量程在0.05A档时:噪音≦0.002A。 (9)工作环境温度:0℃~35℃。 (10)仪器可连续工作。 (11)电源:220VAC±10%50HZ。 (12)单体外形尺寸:280×180×158(mm)。 (13)主机重量:5㎏。 三.工作原理 从光源发出的光经狭缝,滤色器聚焦到样品池上,此单色光通过样品池射到光电倍增管的光阴极面上,使光束由于样品浓度不同所引起透光强度的变化转换成光电流变化,此光电流经放大器放大,并输入到对数转换器、使透光率T转换成光吸收A输出即A=lgT/1=ε·CL式中ε为待测样品的摩尔消光系数,C为样品浓度,采用摩尔/升单位,L为光程,用厘米作单位。根据上式只要测出了A、L和ε就可求出样品浓度C。若从放大器直接输入到记录仪,则在记录仪上绘出的是样品透光率T变化的图谱,若从对数转换器输入到记录仪上,在记录仪上绘出的是样品光吸收变化的图谱。 四.仪器结构 核酸蛋白检测仪、紫外检测仪是单光路结构,由紫外检测器、和记录仪部分组成现将其构造分别说明如下: 1.紫外检测仪: 它由光源、干涉滤色片、样品池、光电倍增管、放大和对数板、低压板和高压板等组成。面板上有四氟塑料管的进样口和出样口,A调零以及调节“光量”大小旋(光

涡轮流量计说明书

LWGY型涡轮流量传感器选型使用说明书

目录 一概述 (1) 二、LWGY基本型涡轮流量传感器 (1) 1、结构特征与工作原理 (1) 2、基本参数与技术性能 (2) 3、安装、使用和调整 (2) 三、LWGYA型涡轮流量传感器 (6) 四、LWGYB型涡轮流量传感器 (6) 五、LWGYC型涡轮流量传感器 (7) 六、维修和常见故障 (8) 七、运输、贮存 (9) 八、开箱注意事项 (9) 九、订货须知 (9)

本产品依据JB/T 9246—1999机械行业标准设计制造 一、概述 LWGY系列涡轮流量传感器(以下简称传感器)基于力矩平衡原理,属于速度式流量仪表。传感器具有结构简单、轻巧、精度高、复现性好、反应灵敏,安装维护使用方便等特点,广泛用于石油、化工、冶金、供水、造纸等行业,是流量计量和节能的理想仪表。 传感器与显示仪表配套使用,适用于测量封闭管道中与不锈钢1Cr18Ni9Ti、2Cr13及刚玉Al2O3、硬质合金不起腐蚀作用,且无纤维、颗粒等杂质的液体。若与具有特殊功能的显示仪表配套,还可以进行定量控制、超量报警等。选用本产品的防爆型式(ExmIIT6),可在有爆炸危险的环境中使用。 传感器适用于在工作温度下粘度小于5×10-6m2/s的介质,对于粘度大于5×10-6m2/s的液体,要对传感器进行实液标定后使用。 如用户需用特殊形式的传感器,可协商订货,需防爆型传感器时,在订货中加以说明。 二、LWGY基本型涡轮流量传感器 2.1 结构特征与工作原理 2.1.1 结构特征 传感器为硬质合金轴承止推式,不仅保证精度,耐磨性能提高,而且具有结构简单、牢固以及拆装方便等特点。 2.1.2 工作原理 流体流经传感器壳体,由于叶轮的叶片与流向有一定的角度,流体的冲力使叶片具有转动力矩,克服摩擦力矩和流体阻力之后叶片旋转,在力矩平衡后转速稳定,在一定的条件下,转速与流速成正比,由于叶片有导磁性,它处于信号检测器(由永久磁钢和线圈组成)的磁场中,旋转的叶片切割磁力线,周期性的改变着线圈的磁通量,从而使线圈两端感应出电脉冲信号,此信号经过放大器的放大整形,形成有一定幅度的连续的矩形脉冲波,可远传至显示仪表,显示出流体的瞬时流量或总量。在一定的流量范围内,脉冲频率f与流经传感器的流体的瞬时流量Q成正比,流量方程为:

TC-100型中流量电子孔口校准器操作使用说明书

一.概述 TC-100/101型电子孔口校准仪是我公司精心研制的新型智能化仪器。该仪器采用微电脑技术,直接显示测量结果,直观、方便、准确。仪器显示采用128*128大屏幕液晶显示屏,中文显示,用户可以根据屏幕提示,直接操作。仪器的标定采用软件标定,通过键盘即可对仪器进行标定。具有维护标定密码保护功能。 该仪器采用孔口流量测量原理,应用微控制器和传感器技术,根据国家环境保护总局《HJ/T368-2007标定总悬浮颗粒物采样器用的孔口流量计技术要求及检测方法》,TC-100适用于中流量采样器的流量校准,TC-101型适用于大流量采样器的流量校准。 该仪器克服了传统人工读取水柱对比曲线换算流量存在误差较大的缺点,是环境监测、卫生防疫、科研院所、工矿企业等领域标定气体流量的理想设备。 二.主要技术参数 量程范围: TC-100中流量孔口流量校准仪:80.0L/min~130.0L/min; TC-101大流量孔口流量校准仪:0.800m3/min~1.400m3/min; 压力传感器量程:-2.5kPa~+2.5kPa 准确度:不超过±1.5%; 重复性:1%; 使用温度:-10℃~+45℃; 供电电源:四节5号电池或外接标准5V2A(5.5mm)电源适配器。 整机功耗:≤0.1W

三.使用方法 将被校准仪器按正常采样放置,打开TSP切割器采样盖,放入一张干净的采样用的滤膜。将孔口校准器与TSP切割器连接。 按住电子孔口校准仪的电源开关3秒,屏幕显示仪器型号,程序版本,并进行自检。 中流量/大流量 电子孔口校准仪 固件版本:v1.00 自检完成进入主菜单。 设置 调零 测量 维护 电压:6.4V 选择“设置”菜单,按确认键,进入设置子菜单,由用户输入环境温度与大气压力。 注:本仪器可自动测量大气压力和环境温度,由于温度传感器及大气压力传感器安装在仪器内与环境实际温度和大气压有所差别,仅供参考,请以实际环境温度和大气压力为准。

继电保护测试仪说明书

微机继电保护测试仪 使 用 说 明 书

目录 目录 (1) 第一部分微机继电保护测试仪使用说明 (3) 第一章装置特点与技术参数 (4) 第二章装置硬件结构 (6) 第三章单机操作模块功能说明 (8) 第四章外接PC机操作说明 (21) 第二部分继保软件操作说明 (21) 第五章软件操作方法简介 (22) 第六章交流试验 (24) 第七章直流试验 (32) 第八章状态系列 (34) 第九章谐波叠加试验 (38) 第十章频率及高低周试验 (41) 第十一章功率方向及阻抗试验 (45) 第十二章同期试验 (49) 第十三章整组试验Ⅰ和Ⅱ (54) 第十四章距离和零序保护 (59) 第十五章线路保护 (64) 第十六章阻抗特性 (70) 第十七章差动保护 (73) 第十八章 6-35KV微机线路保护综合测试 (80) 附录1:外接电脑串行通信口的设置 (85) 附录2:插接U盘等设备时设备驱动安装方法 (87) 附录3:各种继电器的试验方法 (87)

第一部分 继保使用说明

第一章装置特点与技术参数 第一节主要特点 ◆标准的4相电压3相电流输出具有4相电压3相电流输出,可方便地进行各种组合输出进行各种 类型保护试验。每相电压可输出120V,电流三并可输出120A,第4相电压Ux为多功能电压项,可设为4种3U0或检同期电压,或任意某一电压值的情况输出。 ◆单机操作方便单机由方便灵活的旋转鼠标通过大屏幕液晶显示屏进行操作,全部中文显示。可 完成现场大多数试验检定工作,可对各种继电器及微机保护进行检定,并可模拟各种复杂的瞬时性、永久性、转换性故障进行整组试验。开机即可使用,操作方便快捷。 ◆双操作方式,联接电脑运行通过Windows平台上的全套中文操作软件,可进行各种大型复杂 及自动化程度更高的校验工作,可方便地测试及扫描各种保护定值,可实时存贮测试数据,显示矢量图,绘制故障波形,联机打印报表等。 ◆软件功能强大可完成各种自动化程度高的大型复杂校验工作,如三相差动试验、厂用电快切、 备自投试验、线路保护检同期重合闸等,能方便地测试及扫描各种保护定值,进行故障回放,实时存储测试数据,显示矢量图,联机打印报告等。 ◆开关量接点丰富7路接点输入和2对空接点输出。输入接点为空接点和0~250V电位接点兼容, 可智能自动识别。输入、输出接点可根据用户需要扩展。 ◆大屏幕LCD显示屏本机采用320×240点阵大屏幕高分辨率图形液晶显示屏,全部操作过程均在 显示屏上设定,操作界面和试验结果均汉化显示,显示直观清晰。 ◆自我保护采用合理设计的散热结构,并具有可靠完善的多种保护措施及电源软启动,和一定的 故障自诊断及闭锁功能。 ◆具有独立专用直流电源输出装置设有一路110V 及220V专用可调直流电源输出。 ◆性价比高属于跨专业联合设计产品,综合了多专业的先进科技成果。兼具大型测试仪的性能, 和小型测试仪的价位,具有很高的性能价格比。

涡轮流量计使用手册

涡轮流量计使用手册 翻译:付仟骞、韩静静、薛亚斐 整理:韩静静 审核:费节高

目录 1.产品担保时间 (1) 2.涡轮流量剂安装和服务手册 (3) 2.1介绍: (3) 2.2涡轮流量计工作原理 (3) 2.3材料选择和结构 (3) 2.4轴承选择: (4) 2.5流量计检波器选择 (5) 2.5.1高输出磁性检波器-典型范围10:1 (5) 2.5.2低磁检波器-典型范围25:1 (5) 2.5.3磁性检波器输出信号特征 (6) 2.5.4调制载波检波器-型号范围100:1 (6) 2.5.5正交输出选择 (6) 2.5.6危险和抗风化环境线圈缠绕 (7) 2.6流量计校准 (7) 2.7一般安装程序 (8) 2.8滤网/过滤器 (10) 3.流动矫直器和安装配套元件 (11) 3.1流动矫直 (11) 3.2MS安装配件 (12) 3.3信号电缆 (12) 3.4信号调节器/转换器 (12) 4.预防维护保养合故障检修 (13) 4.1耦合线圈测试 (13) 4.2轴承置换 (14) 4.3螺纹轴轴承置换 (15) 4.4无螺蚊轴承 (16) 4.5部分分解图/涡轮内部 (18) 4.6 H0系列校准刻度备用物或置换内部配套元件 (19) 4.7推荐备用和替换部分 (19) 5.涡轮流量计存储器 (20) 附录A (22) 危险识别 (22) 风险评估 (22)

1.产品担保时间 5年限制担保 API精确HO系列—包括耦合线圈液体精确HO系列—包括耦合线圈气体精确HO系列—包括耦合线圈

注:涡轮流量计理想的适用于干静的液体和气体。特定的Hoffer涡轮流量计可提高到泥浆类型的液体。当涡轮流量计安装在“脏”类型的流体,流量计内部将完全磨损。磨损的速度是由流量速度、泥浆类型、液体中颗粒百分比共同作用的。HFC用在泥浆类型,就不能预测流量计内部的使用寿命。我们标准的产品保证时间并不适用于流量计使用在泥浆中。

流量检测装置说明书

流量检测装置设计说明书 一、装置需求: 1. 100点流量差压信号的采集。用键盘输入流量系数,输入时可显示; 2.围0-1000l/min,采集周期0.5s,信号4-20mA,分辨力0.1%; 3.要求运用数字滤波(方法自选); 4.计算瞬时流量(l/min)、累计流量(m3/h),并显示; 5.操作人员可随时修改流量系数和切换显示容(瞬时/累计流量)。 二、设计说明书要求: 1.系统构成框图及构成说明,包括主要部件的选型及依据; 2.DSP与A/D转换芯片连接的电原理图; 3.程序框图,包括主要流程; 4.采集、数字滤波、流量计算程序清单。 三、差压式流量计基本理论 1.节流装置工作原理 差压式流量计是根据伯努力方程和流体连续性原理用差压法测量流量的,其节流装置工作原理如图1所示,在横截面H处:流体的平均流速是v 1 ,密度是ρ 1,横截面积是A 1 ;在横截面L处:流体的平均流速是v 2 ,密度是ρ 2 ,横截面积 是A 2 。 图1 差压流量计工作原理图根据流体流动连续性原理有如下关系式: v 1·A 1 ·ρ 1 =v 2 ·A 2 ·ρ 2 (1) 如果流体是液体,可认为在收缩前、后其密度不变: ρ 1=ρ 2 =ρ(2) 根据瞬时流量的定义,即单位时间流体流经管道或明渠某横截面的数量,所

以液体的体积瞬时流量: 2211A v A v q v ?=?= (3) 根据伯努利方程(能量守恒定律),在水平管道上Z1=Z2,则有如下关系式: 2 2 2 2 222 111v P v P ρρ+ =+ (4) 应用伯努利方程和流动连续性原理,在两个横截面上压力差则有如下关系式: )(2 212 221v v P P P -= -=?ρ (5) 将(3)代入(5)式,并整理,则得: 2221 2])( 1[2 v A A P -= ?ρ (6) 由于4 2 1D A ?= π, 4 2 2d A ?= π, 定义直径比D d = β, 其中d 为工作状况下节流件的等效开孔直径,D 为管道直径,则得到: 222 4 )1(2A q P v βρ -=? (7) 这样可推导出以下的理论流量公式: 1 2 4 24 11ρπ β P d q v ??-= (8) 又由于流量系数C 的定义是:C= 实际流量/理论流量,可得出节流式差压流 量计普遍适用的测量体积流量的实际流量公式: ρ π β εP d C q v ??-?= 24 12 4 (9) 其中,ε为被测介质的可膨胀性系数:对于液体=1; 对气体、蒸气等可压缩流体<1 。 根据累计流量的定义,即在某一段时间流过某横截面流体的总量,所以液体的体积累计流量为: dt q Q t v v ?= (10) 因此,我们只要检测出差压即可分别计算出瞬时流量和累计流量的大小。 2. 差压变送器工作原理 在采用差压方式进行流量测量时,其流量 v Q 与差压P ?呈非线性关系,即差 压信号与流量之间存在一个开方关系。为了线性的表达流量,需要对测量系统总

IXIA测试仪使用手册

IXIA测试仪使用手册 一、设备开机、关机 (一)开机 打开IXIA测试仪电源,等待设备启动完成,需将测试客户端IP设置为192.168.1.200,测试仪IP地址为192.168.1.100,开IxNetwork或IxLoad可连接测试仪表明设备完成开机。 (二)关机 在运行中输入mstsc进入远程桌面,连接到计算机192.168.1.100,在运行中输入shutdown.exe -s -t 3让设备在3秒内关闭,让系统自动关闭。 二、二三层测试配置(IxNetwork) 使用IxNetwork配置测试基本流程如下图所示。 (一)添加测试端口 点击标题栏中的 或Overview表页中的

连接192.168.1.100测试板卡 添加测试用端口

然后点击OK键,完成测试端口添加。 (二)配置端口、协议 启用测试端口Ping及ARP,如下图所示。 添加测试端口IP地址、网关,并使能端口,如下图所示,添加的网关地址需是实际存在的,可以是交换机的网关地址或测试端口对端IP地址。

(三)配置流量 选择配置流量。 Type of Traffic选项可选择Raw、Ethernet/vlan、IPV4分别对应原始报文流(需手动编辑,用来打广播包流)、二层流、三层流(需配置IP地址及网关),Bi-Directional表示流是双向流。 1、IPV4(三层流)

在设置好Type of Traffic、Traffic Mesh以及选择好端口后,点击添加Endpoint。点击NEXT,在Packet/QoS、Flow Group Setup、Frame Setup、Rate Setup保持默认配置。点击NEXT,进入Flow Tracking,选择Traffic Item选项。点击NEXT,在后续Protocol Behaviors、 Preview以及Validate中保持默认选项,同时检查配置的有效性。

涡轮流量计说明书

目录 1、概述 1.1 搬运时应注意的事项 1.2 存放应注意的事项 1.3选择安装地点应注意的事项 1.4限制使用无线电收发机应注意的事项 1.5防爆型仪表安装注意事项 2、技术性能 2.1 气体涡轮流量传感器的技术性能 2.2 LRT-I现场显示表(锂电池供电)的技术性能 2.3 LRT-Ⅱ现场显示表(外供电)的技术性能 2.4 LRT-Ⅲ现场显示表(外供电)的技术性能 3、结构与工作原理 3.1气体涡轮流量传感器的基本结构 3.2 工作原理 4、外形尺寸及安装 4.1 外形尺寸 4.2 安装 5、接线 5.1放大器及现场显示表的接线 5.2 应用举例 6、流量传感器的维护 7、流量传感器故障及故障排除方法 装箱单

1、概述 本说明书叙述了LWGQ气体涡轮流量计的标准技术规格、型号及其安装、操作和维护。请在使用前阅读本手册。但在手册中没有叙述用户的不同特点,也未对每一次的技术规格、结构或部件的修改作订正,因为有些修改不会对仪器的功能和操作有影响。 LWGQ型气体涡轮流量计是一种精密流量测量仪表,与相应的流量积算仪表、现场显示表等配套可用于测量液体的流量和总量。它被广泛用于石油、化工、冶金、科研等领域的计量、控制系统。尤其适用于天然气、干煤气、压缩空气等的测量。 流量计有多种输出和显示方式(详见型号规格代码表)。 1.1 搬运时应注意的事项 为防止受到损坏,流量计在搬运到用户使用地点之前请使用原包装。 1.2 存放应注意的事项 仪器到达之后应及时安装。对于电池供电的LRT-I表头,未使用时应将电源插针置于“OFF”(断开)位置,以免电池耗电影响电池的使用寿命。如需存放,请注意下列事项: a)可能的条件下,不打开包装箱存放。 b)如已打开包装,或已使用过仪表,请把LRT-I表头电源跳线器插在“OFF”位置,并使用原包装。 存放地点应具备下列条件: a)防雨防潮 b)机械振动小,避免碰撞冲击 c)温度在-30~+60℃。理想温度在25℃左右。 d)如存放在室外,仪表性能就要受到影响。因此一旦仪表搬运到安装地点,就要尽快地安装起来。 1.3选择安装地点应注意的事项 流量计的设计已考虑到了在恶劣环境条件下的情况,但是为长期保持其精确度和稳定性,在选择安装地点时必须注意下列事项:环境温度:避免安装在环境温度变化很大的场所。如果受到设备的热辐射时,须有隔热通风的措施。 环境空气:避免把流量计安装在含有腐蚀性气体的环境中。如果一定要安装在这样的环境中,则必须提供通风措施。 机械振动和冲击:仪表的结构很坚固,但在选择安装场所时应尽量避免机械振动或碰撞冲击。如果仪表安装在振动较大的管道上,则管道需加支撑。 其它:仪表的周围应有充裕的空间,以便安装和定期检修。 1.4限制使用无线电收发机应注意的事项 流量计的电气部分是可以抗高频电噪声干扰的。但是如果太靠近仪表处使用无线电收发机,那么高频噪声干扰就会影响到仪表。查看一下仪表安装场所,仪表是否受到无线电收发机的影响(把无线电收发机从几米远处移向仪表,看是否受到影响)。如有的话,就把收发机远离该场所。 1.5防爆型仪表安装注意事项 流量计的设计可用于“爆炸性环境用电气设备通用要求(GB3836.1)”,“爆炸性环境用防爆电气设备隔爆型电气设备“d””及“爆炸性环境用防爆电气设备本质安全型电路和电气设备“i””标准所规定的1区和2区危险地区。

相关文档