BKMJ SERIES SELF-HEALING SHUNT

CAPACITOR

1. Application:

Appied to 50/60HZ and rated voltage 0.23~0.525KV low voltage power supply system to be used to improve network quality and upgrade power factor.

2. Main Feature:

2.1 With thickly edge coated ladder-shaped film, the capacitor has good capacitance stabality and reliability;

2.2 Inwardly equipped self-discharge resistor and safety equipment. The capacitor operates safety and reliability;

2.3 Specially designed dry type structure, the capacitor is protected from hazard of blow out, oil-leakage and combustion;

2.4 The packet of the capacitor has impregnated specially made the capacitor have both characteristics of dry-type and oil immersed.

3.Main technical indexes:

3.1 Service conditions: Altitude is not exceeding 2000M;

Ambient temperature:

Highest 50℃lowest -25℃indoor;

Highest 50℃lowest -40℃outdoor.

3.2 Rated voltage: 0.23~0.525KV;

3.3 Capacitance tolerance: 0~+10%;

3.4 Loss: Under the power frequency rated voltage lower than 1W/KV AR at 20℃;

3.5 Max permissible over-V oltage: 110% rated voltage;

3.6 Max permissible over-V oltage: 130% rated voltage;

3.7 Self sustained discharge ability: The residual voltage reduces to 50V or lower within 3 minutes after power off;

3.8 Thesting voltage: Between terminals and containers 3KV for 10 seconds;

3.9 Knock-off inlet hole is used for lead-in cable. Diameter is 20mm 40mm 50 ;

3.10 Applicable standard: GB 12747; IEC 831.

BKMJ系列自愈式低压并联电力电容器

一、用途:

适用于频率50/60HZ,额定电压0.23~0.525KV的低压供电系统中,用来提高功率因数,减少线路损耗,改善电网质量。

二、主要特点:

2.1 边缘加厚的梯形镀膜,使电容器具有良好的电容稳定性,工作寿命长;

2.2 内装自放电电阻系统和保险装置,使电容器在运行中避免了漏油、爆炸、燃烧;

2.3 经过特殊浸渍的电容器芯包,使电容器具有干式与油浸式电容器的双重优点。

三、主要技术参数:

3.1 使用条件:海拔≤2000m;环境温度:户内-25℃~+50℃

户外-40℃~+50℃

3.2 额定电压:0.23~0.525KV;

3.3 容量偏差:0~+10%;

3.4 损耗:在工频额定电压下,20℃时低于1W/Kvar;

3.5 最高允许过电压:1.10倍额定电压;

3.6 最高允许过电流:1.30倍额定电流;

3.7 自放电特性:放电电阻使电容器断开电源3分钟后,剩余电压降至50V或更低;

3.8 试验电压:极间2倍额定电压10s;极壳间3KV,10秒钟;

3.9 电缆进线孔采用敲落式进线孔,孔直径:20mm,40mm,50mm;

3.10 符合标准:GB 12747 IEC831。