箱梁计算书(MIDAS分析)
MIDAS连续梁计算书
目录第1章设计原始资料 (1)1.1设计概况 (1)1.2技术标准 (1)1.3主要规范 (1)第2章桥跨总体布置及结构尺寸拟定 (2)2.1尺寸拟定 (2)2.1.1 桥孔分跨 (2)2.1.2 截面形式 (2)2.1.3 梁高 (3)2.1.4 细部尺寸 (4)2.15 主要材料及材料性能 (6)2.2模型建立与分析 (7)2.2.1 计算模型 (8)第3章荷载内力计算 (9)3.1荷载工况及荷载组合 (9)3.2作用效应计算 (10)3.2.1 永久作用计算 (10)3.3作用效应组合 (16)第4章预应力钢束的估算与布置 (20)4.1力筋估算 (20)4.1.1 计算原理 (20)4.1.2 预应力钢束的估算 (24)4.2预应力钢束的布置(具体布置图见图纸) (27)第5章预应力损失及有效应力的计算 (29)5.1预应力损失的计算 (29)5.1.1摩阻损失 (29)5.1.2. 锚具变形损失 (30)5.1.3. 混凝土的弹性压缩 (30)5.1.4.钢束松弛损失 (31)5.1.5.收缩徐变损失 (31)5.2有效预应力的计算 (32)第6章次内力的计算 (33)6.1徐变次内力的计算 (33)6.2预加力引起的次内力 (33)第7章内力组合 (35)7.1承载能力极限状态下的效应组合 (35)7.2正常使用极限状态下的效应组合 (37)第8章主梁截面验算 (41)8.1正截面抗弯承载力验算 (41)8.2持久状况正常使用极限状态应力验算 (44)8.2.1 正截面抗裂验算(法向拉应力) (44)8.2.2 斜截面抗裂验算(主拉应力) (46)8.2.3混凝土最大压应力验算 (49)8.2.4 预应力钢筋中的拉应力验算 (50)8.3挠度的验算 (51)小结 (53)第1章设计原始资料1.1 设计概况设计某预应力混凝土连续梁桥模型,标准跨径为35m+50m+35m。
施工方式采用满堂支架现浇,采用变截面连续箱梁。
Midas预应力混凝土连续箱梁分析算例课件
MIDAS软件是一款功能强大的有限元 分析软件,可以对预应力混凝土连续 箱梁进行精确的建模和分析,为桥梁 设计提供可靠的技术支持。
预应力混凝土连续箱梁的设计和施工 需要综合考虑多种因素,包括结构形 式、材料特性、施工方法等,以确保 桥梁的安全性和经济性。
展望
随着科技的不断进步和工程实 践的积累,预应力混凝土连续 箱梁的设计和施工将不断得到
预应力体系
通过在混凝土浇筑前施加 预压应力,改善了结构的 受力性能,提高了梁的承 载能力和稳定性。
横向联系
连续箱梁采用横隔板和横 梁等横向联系构件,确保 了结构的整体稳定性。
预应力混凝土连续箱梁的设计原理
力学分析
根据结构力学原理,对连 续箱梁进行受力分析,确 定各截面的弯矩、剪力和 扭矩等。
预应力设计
特殊情况处理
针对模型中可能出现的特殊情况, 如施工阶段、预应力张拉等,说明 处理方法。
计算结果分析
01
02
03
04
变形分析
分析模型在受力后的变形情况 ,包括挠度、转角等。
应力分析
分析模型中的应力分布和大小 ,包括正应力和剪应力。
预应力张拉分析
针对预应力张拉的情况,分析 张拉后的应力分布和损失。
结果对比
优化和完善。
未来可以进一步研究新型材料 和结构形式在预应力混凝土连 续箱梁中的应用,以提高桥梁
的性能和耐久性。
有限元分析软件的功能和精度 将不断提升,为预应力混凝土 连续箱梁的分析和设计提供更 加可靠的技术支持。
未来可以通过加强科研合作和 技术交流,推动预应力混凝土 连续箱梁领域的创新和发展, 为我国桥梁事业的发展做出更 大的贡献。
05 参考文献
CHAPTER
现浇箱梁midas结构计算书
从化至东莞高速公路第一合同段沙浦枢纽立交广惠高速跨线桥左幅第四联连续箱梁验算报告计算复核审核二〇一〇年六月目录1工程概况 (1)1.1概述 (1)1.2主要设计标准 (1)1.3主要材料 (2)1.4结构形式简述 (2)2计算模型及计算参数选取 (3)2.1计算模型建立 (3)2.2计算荷载 (5)2.3计算工况及验算内容 (7)3上部结构计算 (9)3.1计算模型 (9)3.2短暂状况构件应力验算 (10)3.3上部结构计算小结 (24)4 横梁计算 (25)广惠高速跨线桥左幅第四联连续箱梁验算报告1工程概况1.1概述本联为跨径组合为(3×25)m的连续箱梁,上部结构采用连续箱梁,梁高等高为1.6m,悬臂宽度2.3m,桥面横坡通过箱梁整体旋转形成,箱梁顶、底板始终保持平行,边腹板保持2.75:1的斜率不变。
箱梁顶宽16.25m,采用单箱双室。
本桥预应力砼连续箱梁按照部分预应力混凝土A类构件设计。
下部结构采用板式桥墩,支座采用盆式支座。
1.2主要设计标准(1)设计荷载:公路—I级;(2)桥面宽度:桥宽16.25米;(4)横坡:2%。
(5)地震加速度为0.05g,对应地震基本烈度Ⅵ度;广东省公路勘察规划设计院/北京交科公路勘察设计研究院1(6)环境类别:Ⅰ类环境(7)安全等级:一级1.3主要材料(1)混凝土现浇箱梁采用C50砼;护栏采用C30砼。
具体以细部图纸为准。
(2)钢筋钢筋应符合GB13013-1991和GB1499-1998的规定。
凡钢筋直径≥12mm者,均采用HRB335钢筋;凡钢筋直径<12mm者,均采用热轧R235钢筋。
(3)钢绞线钢绞线采用GB/T5224-2003标准生产的低松弛高强度钢绞线。
单根钢绞线直径15.20mm,公称面积140mm2,标准强度1860MPa,弹性模量1.95×105MPa。
1.4结构形式简述本联组合跨径为(3×25)m ,上部结构均采用预应力混凝土斜腹板连续箱梁。
Midas预应力混凝土连续箱梁分析算例课件
结构建模助手截和钢筋表单数据的保存和打开 41
将定义好的表单数据 予以保存,点击
另存为…按钮 以便后用
将原先保存的数据 重新打开,以借鉴 已有的经验,减少 重复工作
结构建模助手的文件 后缀为wzd
Fluid Mechanics and Machinery
跨度信息
确定桥梁的跨度信息:端部支点、 22 内部支承的数量及位置、跨经等
分配单元>经由选择的:在模型窗口 中选择单元;号:直接输入单元号
模型窗口选择单元或直接输入单元 号以后,点击 添加/替换按钮,梁 单元的单元号、单元长度、支承位 置信息将会以表格的形式列出。
如果被选单元的i端有一般支承 条件,支承一栏会显示I。被选 单元不是一般支承条件而是其 它的边界条件时,就需用户在 相应位置(I/J)中选择一项来 补充支承一栏的信息
为边界条件建立三个边界节点
19
选择节点31,这是跨中节点
将节点31复制到z=-7.13m处,生成节点62
Fluid Mechanics and Machinery 流 体 力 学 与 流 体 机 械
为边界条件建立三个边界节点
20
选择节点1,61; 这是两端节点
将所选节点复制到z=-2.7m处, 生成节点63,64
这里介绍纵向钢筋表单
定义钢筋纵向布置的起始和终 止位置,定义钢筋横向布置的 数量、直径和间距
Fluid Mechanics and Machinery 流 体 力 学 与 流 体 机 械
纵向钢筋布置的控制参数
39
梁名称:选择在跨度信息里定义好的梁。 如果先前没有定义好梁,点击右侧[…]按钮来定义新的梁
16-Midas Civil应用—变截面预应力连续箱梁
01Midas Civil应用—变截面预应力连续箱梁1、三跨预应力混凝土连续箱梁建模及分析(1)基本概况一座三跨预应力混凝土连续箱梁桥桥梁长度:L=30m+50m+30m=110m,为钢筋混凝土结构;预应力布置形式:T构部分配置顶板预应力,边跨配置底板预应力。
材料特性混凝土:主梁采用C50混凝土,桥墩C40混凝土;钢材:预应力采用“Strand1860”;荷载:自重,程序自动计算;恒荷载:自重;预应力:钢束(φs15.2mm×37);截面积:Au=5180mm2,孔道直径:80mm;预应力与管道摩擦系数:0.17;张拉控制应力:1395MPa;移动荷载:适用规范:公路工程技术标准(JTG B01-2003)荷载种类:公路I级,车道荷载,即CH-CD。
(2)Midas Civil 连续梁桥分析步骤三跨预应力混凝土连续箱梁分析步骤如下:①设置操作环境及项目信息②定义材料和截面③建立结构三维模型④输入静力荷载⑤输入移动荷载数据⑥输入荷载组合⑦运行结构分析⑧查看分析结果(3)设置操作环境及项目信息打开【工具】/【单位系】/将单位体系设为KN,mm。
该单位可以根据输入数据的种类任意转换。
打开【文件】 /【项目信息】/完善基本信息。
(4)定义材料和截面。
打开【特性】/【截面特性值】/【截面】/【添加】/【设计截面】/【截面类型:单箱单室】,截面号:1,名称:跨中;定义PSC截面钢筋。
打开【特性】/【截面特性值】/【截面管理器】/【钢筋】;添加纵向钢筋:1、类型直线,板顶,Z:0.06m,数量65根,间距0.14m,直径:φ16mm;2、类型直线,板底,Z:0.06m,数量33根,间距0.15m,直径:φ16mm;抗剪钢筋:两端i、j钢筋相同,弯起钢筋(间距1.5m,角度45°,Asb:0.0005㎡);抗扭钢筋(间距:0.2m,箍筋Asv1:0.0004㎡,纵筋Ast:0.002㎡);抗剪箍筋(间距:0.2,Asv:0.0008㎡),计算箍筋内表面包围的截面核芯面积(打开),保护层厚度:0.05m,包括翼缘和悬臂。
45+80+45三跨预应力混凝土变截面连续箱梁计算书
三跨预应力箱型连续梁桥分析与设计学院专业年级班别学号学生姓名指导教师2010 年6 月2 日目录1.概要 (2)1.1 桥梁基本数据以及一般截面 (2)2.设定建模环境 (3)3.桥梁分析 (4)3.1 定义材料和截面 (4)3.2 建立结构模型 (6)3.3 建立荷载组 (9)3.4 输入荷载 (10)3.5 定义并建立施工阶段 (11)3.6 分析 (14)3.7 分析运行结果 (14)三跨预应力箱型连续梁桥分析与设计1.概要本桥为45+80+45三跨预应力混凝土变截面连续箱梁,采用悬臂法施工。
在此利用MIDAS进行分析与设计,其分析模型如图1所示:图1 分析模型(竣工后)1.1 桥梁基本数据以及一般截面1.桥梁基本数据如下:桥梁类型: 三跨预应力箱型连续梁桥桥梁长度: L =45.0 + 80.0 + 45.0 = 170.0 m桥梁宽度: B = 35.0 m斜交角度: 105˚2. 桥梁一般截面桥梁纵向剖面图与标准截面图分别如图2、3所示:图2 纵向剖面图3 标准截面2.设定建模环境文件/新建项目文件/保存(连续梁桥)工具/单位体系长度>m;力>KN图4 设定单位体系3.桥梁分析3.1 定义材料和截面模型/材料与截面特性/材料(输入结果如图5所示)1.混凝土:主梁采用JTG04(RC)规范的C50混凝土,桥墩采用JTG04(RC)规范的C40混凝土。
2.钢材:采用JTG04(S)规范,在数据库中选Strand1860。
3.截面:箱梁截面尺寸为截面尺寸如图4所示,墩采用实腹轨道型截面,其尺寸为:H=12m、H=3.5m。
图5 定义材料及截面3.2 建立结构模型参照图6(a)建立预应力箱型梁模型。
将每个桥梁段看作一个梁单元,以零号块和桥墩的交点、桥墩和桥墩的中心距离为基准分割单元。
满堂支架法区段应考虑下部钢束的锚固位置分割单元。
1.建立结构单元模型/节点/建立(如图6(b))将每个桥梁段看作一个梁单元,以零号块和桥墩的交点、桥墩和桥墩的中心距离为基准分割单元。
MIDAS--箱梁钢筋吊装架计算书
3.3.4结构变形图
最大弯距M =10.0kN·m
最大应力σ=95.3MPa<[σw]=145MPa
最大变形ν=11mm,满足箱梁钢筋的变形要设置吊点,纵向12个吊点,共设置48个吊点.腹板顶单个吊点重量G1=20t/12=1.67t,翼板G2=10t/12=0.83t.
3
3.1
按吊装架设计结构尺寸进行建模计算,下图分别为建模后吊装架横向及纵向示意图。
考虑安全系数等影响,各吊点位置受力以腹板单个吊点按2吨设置,翼板单个吊点按1吨设置。
钢筋整体吊装结构检算
1
1.1、《钢结构工程》;
1.2、《材料力学》(科学技术文献出版社);
1.3、《钢结构设计规范》(GB50017-2003);
1.4、《路桥施工计算手册》(人民交通出版社)。
2
2.132米箱梁钢筋总重约60吨,考虑钢筋重量全部由吊装架承担,需对钢筋吊装架的强度及刚度进行计算,确保在吊装箱梁钢筋笼时吊装架能够满足变形及强度要求。
3.2
吊装架主要使用材料为Q235型钢,查钢结构设计规范(GB50017-2003)表3.4.1-1主要材料强度指标为
序号
材料名称及强度等级
强度种类
容许值(N/m3)
1
Q235
抗拉、抗弯、抗压(f)
190
抗剪(f)
110
3.3采用midas/civil建模进行结构分析
3.3.1应力图
3.3.2弯矩图
midas-连续梁计算书
第1章89#~92#预应力砼连续梁桥1.1结构设计简述本桥为27+27+25.94现浇连续箱梁,断面型式为弧形边腹板大悬臂断面,根据道路总体布置要求,主梁上下行为整体断面,变宽度32.713m -35m,单箱5室结构变截面。
箱梁顶板厚度为0.22m,底板厚度0.2m;支点范围腹板厚度0.7m,跨中范围腹板厚度0.4m。
主梁单侧悬臂长度为4.85m,箱梁悬臂端部厚度为0.2m,悬臂沿弧线一直延伸至主梁底板。
主梁两侧悬臂设置0.1m后浇带,与防撞护栏同期进行浇筑。
本桥平、立面构造及断面形式如图11.1.1和图11.1.2所示。
图11.1.1 箱梁构造图图11.1.2 箱梁断面图纵向预应力采用φs15.2高强度低松弛钢绞线(Ⅱ级)(GB/T5224-1995),标准强度f=1860MPa。
中支点断面钢束布置如图11.1.3所示。
pk图11.1.3 中支点断面钢束布置图主要断面预应力钢束数量如下表截面位置边跨跨中中支点中跨跨中钢绞线(φs15.2)束数363636墩横梁预应力采用采用φs15-19,单向张拉,如下图。
1.2主要材料1.2.1主要材料类型(1) 混凝土:主梁采用C50砼;(2) 普通钢筋:R235、HRB335钢筋;(3) 预应力体系:采用φs15.2高强度低松弛钢绞线(Ⅱ级)(GB/T5224-1995),f=1860MPa;预应力锚具采用符合GB/T14370-2002《预应力筋锚具、标准强度pk夹具和连接器》中Ⅰ类要求的优质锚具;波纹管采用符合JT/T529-2004标准的塑料波纹管。
1.2.2主要材料用量指标本桥上部结构主要材料用量指标如表11.2.2-1所示,表中材料指标均为每平米桥面的用量。
表11.2.2-1 上部结构主要材料指标材料全桥用量用量指标单位用量单位用量指标混凝土(C50)m32015.8m3/m20.737预应力钢绞线t35.902kg/m213.131普通钢筋t345.221kg/m2126.2611.3结构计算分析1.3.1计算模型结构计算模型如下图所示。
Midas Civil计算书(钢箱梁)
(4)《钢结构设计规范》
(GB50017-2003)
(5)《公路桥涵钢结构及木结构设计规范》
(JT40+60+40)计算书
(6)《公路桥涵施工技术规范》 (7)《钢结构工程施工质量验收规范》 (8)《铁路桥涵钢结构设计规范》
(JTG/T F50-2011) (GB 50205-2001) (TB 10002.2-2005)
处L为的计算跨径:边跨L/600 = 40000/600 = 66.7mm,中跨L/600=60000/600=100mm
2.5 复核计算标准、规范及其它依据
(1)《公路工程技术标准》
(JTG B01-2003)
(2)《公路桥涵设计通用规范》
(JTG D60-2004)
(3)《公路钢筋混凝土及预应力混凝土桥涵设计规范》(JTG D62-2004)
图 4.1 活载正挠度
图 4.1 活载负挠度 《公路桥涵钢结构及木结构设计规范》(JTJ 025-86)第1.1.5条规定:如果车辆荷 载在一个桥跨范围内移动产生正负两个方向的挠度时,计算挠度应为其正负挠度的最大 绝对值之和,边跨和中跨最大挠度均位于跨中分别为:22.6mm、40.8mm结构刚度满足规范 要求。
35m箱梁计算书
宝天高速公路35m箱梁计算书第一章概述总体概述上部箱梁构造为5×35连续小箱梁,桥宽12.25米,由4榀小箱梁联结构成,布置图如下图所示。
设计荷载公路Ⅰ级。
本计算只对边梁单榀箱梁进行分析,模型为5×35m=175m连续箱梁,桥面铺装及防撞护栏以均布荷载方式加载,活载以单列车队乘以横向分布系数加载。
箱梁横断面图纵向、横向分析分别采用MDIAS和桥梁博士计算分析程序,计算分析采用的主要规范有:1.《公路桥涵设计通用规范》(JTGD60-2004)2.《公路钢筋混凝土及预应力混凝土桥涵设计规范》(JTGD62-2004)3.《公路工程技术标准》(JTGB01-2003)(一)技术指标设计荷载:公路Ⅰ级。
桥面宽度:0.5+11.25+0.5=12.25米,单幅桥。
标准桥面横坡:2%跨径:35米斜度:0°,10°,20°,30°,40°主梁片数:4片梁。
预制梁长:34.3米。
预制梁高:1.8米。
桥面铺装:9cm沥青混凝土。
混凝土调平层: 8cm50号混凝土。
(二)相关参数相对温度 75%桥面板与其它部分的温差为±5°预应力管道成形为钢波纹管管道摩擦系数u=0.25管道偏差系数λ=0.0025l/米钢筋回缩和锚具变形为6mm(三)主要材料1.混凝土材料预制箱梁、横隔板 50号混凝土现浇连续段、封锚端、湿接缝 50号混凝土现浇桥面层50号混凝土主梁采用50号混凝土,力学性能见表1.1混凝土力学性能表表1.1材料项目50号混凝土弹性模量(Mpa)35000容重(吨/米3) 2.55热膨胀系数0.00001标准抗压强度(Mpa)fck32.4设计抗压强度(Mpa)fcd22.4容许压应力(Mpa)0.5×fck16.2标准抗拉强度(Mpa)ftk2.65设计抗拉强度(Mpa)ftd1.83容许拉应力(Mpa)0.7×ftk1.852.预应力材料预应力筋均采用符合ASTM A416-96a标准的高强低松弛270级钢绞线,公称直径φj15.24mm,公称面积为140mm2,标准强度为MPaR by1860=,,控制张拉应力为1395MPa。
midas建模计算(预应力混凝土连续箱梁桥)
midas建模计算(预应力混凝土连续箱梁桥)midas建模计算(预应力混凝土连续箱梁桥)纵向计算模型的建立1.设置操作环境1.1打开新项目,输入文件名称,保存文件1.2在工具-单位体系中将单位体系设置为“m”,“KN”,“kj”和“摄氏”。
2.材料与截面定义2.1 材料定义右键-材料和截面特性-材料。
C50材料定义如下图所示。
需定义四种材料:主梁采用C50混凝土,立柱、盖梁及桥头搭板采用C30混凝土,基桩采用C25混凝土。
预应力钢绞线采用1860级高强低松弛s 15.24钢绞线。
钢绞线定义时,设计类型:钢材;规范:JTG04(S);数据库:strand 1860,名称:预应力钢筋2.2 截面定义2.2.1 利用SPC(截面特性值计算器)计算截面信息(1)在CAD中x-y平面内,以mm为单位绘制主梁所有的控制截面,以DXF 格式保存文件;绘图时注意每个截面必须是闭合的,不能存在重复的线段,并且对于组成变截面组的线段,其组成线段的个数应保持一致。
(2)在midas工具中打开截面特性计算器(SPC),在Tools-Setting中将单位设置为“KN”和“mm”;(3)从File-Import-Autocad DXF导入DXF截面;(4)从Model-Section-Generate中选择“Type-Plane”;不勾选“Merge Straight Lines”前面的复选框;Name-根据截面所在位置定义不同的截面名称从而生成截面信息;(5)在Property-Calculate Section Property 中设置划分网格的大小和精度,然后计算各截面特性;(6)从File-Export-MIDAS Section File导出截面特性文件,指定文件目录和名字,以备使用。
2.2.2 建立模型截面(1)右键-材料和截面特性-截面-添加-设计截面,选择设计用数值截面。
单击“截面数据”选择“从SPC导入”,选择刚导出的截面特性文件,并输入相应的设计参数。
MIDAS钢箱梁计算书
12
恒+活应力云图(主拉应力,单位:MPa)
由上述结果可知,桥面板顶板局部最大主拉应力为 196.9Mpa,虽能满足规 范要求,但主拉应力偏大。建议悬臂处的加劲肋改为 T 型加劲肋或 U 型加劲 肋。
恒+活应力云图(主压应力,单位:MPa)
由上述结果可知,桥面板顶板局部最大主压应力为 151.1Mpa,满足规范要 求。发生在翼缘挑梁根部下缘。
部位 钢箱梁
截面位置 上缘 下缘
腹板剪力
最大压应力 -12.98 -128.15 /
最大拉应力 124.3 12.98 /
最大剪应力 /
103.25
容许值 210 210 120
从上表可以看出正应力满足要求,腹板剪应力虽满足要求,但偏大,建议 对腹板至支座之间的横隔板进行局部加强。
1.1.5端横梁计算
步骤
施工内容
cs1
中间支点节段架设
cs2
其余梁段架设
cs3
合拢段施工
cs4
二期恒载
(2)施工阶段应力计算
上缘最大应力(压应力为负,单位:MPa)
上缘最小应力(压应力为负,单位:MPa)
下缘最大应力(压应力为负,单位:MPa)
4
下缘最小应力(压应力为负,单位:MPa)
最大剪应力(单位:MPa)
施工阶段主梁应力(压应力为负,单位:MPa)
/
/
/
最大剪 应力
/ -50.21
容许值
210 210 120
由上图表可以看出,在施工阶段,主梁的正应力和剪应力均满足规范要
求。
(3)施工阶段变形
跨中竖向位移(单位:mm)
从上图可以看出成桥阶段跨中竖向位移为向下 96.8mm。 1.1.3.1.5纵向计算分析结果
MIDAS检算现浇梁支架计算书3-1.1-整体模型
目录1 计算依据 (1)2 工程概况 (1)3 施工方案综述 (2)4 现浇支架计算 (2)4.1 支架设计 (2)4.2 设计参数及材料强度 (3)4.2.1 设计参数 (3)4.2.2 材料设计强度 (4)4.3 荷载分析 (4)4.3.1 荷载类型 (4)4.3.2 荷载组合 (4)4.3.3 箱梁混凝土自重 (5)4.3.4 模板自重 (6)4.3.5 分配梁12.6工字钢自重 (6)4.3.6 单片贝雷梁荷载统计 (6)4.4 建立模型计算分析 (6)4.4.1 模型单元 (6)4.4.2 边界条件 (7)4.4.3 模型荷载 (7)4.4.4 支架体系计算模型 (7)4.4.5 计算结果 (7)5 结论 (11)32.6m简支箱梁现浇支架计算书1 计算依据(1)连续梁相关施工图(2)《钢结构设计规范》GB50017-2003(3)《建筑结构荷载规范》(GB50009-2012)(4)《桥梁临时结构设计》中国铁道出版社(5)《路桥施工计算手册》人民交通出版社(6)《装配式公路钢桥多用途使用手册》(7)Midas设计手册2 工程概况32m现浇简支梁全长32.6m,计算跨度31.1m,截面中心梁高3.05m,梁顶宽为12m,梁底宽5.5m,墩高9.85m,每片梁重836.8t。
箱梁正视图、断面图分别如图2.1.1所示。
图2.1.1 简支箱梁正视图图2.1.2 简支箱梁断面图3 施工方案综述简支梁现浇施工工序为施工准备→支架搭设→支架预压→调整模板→绑扎钢筋→安装内模→浇筑混凝土→养护→支架拆除,具体施工流程简图3.1.1所示。
施工准备测量放样支架搭设安装底模及外模支座安装支架预压沉降观测调整模板安装、绑扎钢筋安装内模测量中线及标高检查合格浇筑混凝土及预应力养护支架拆除图3.1.1 简支梁现浇流程图4 现浇支架计算4.1 支架设计现浇支架采用钢管柱+分配梁+贝雷梁结构体系,采用φ530x10钢管做受力支柱,单层贝雷片做受力纵梁。
新规范35m箱梁计算书
新规范35m箱梁计算书.一、总体概述上部箱梁构造为5×35连续小箱梁,桥宽12.25米,由4榀小箱梁联结构成,布置图如下图所示。
设计荷载公路Ⅰ级。
本计算只对边梁单榀箱梁进行分析,模的主要规范有:1.《公路桥涵设计通用规范》(JTGD60-2004)2.《公路钢筋混凝土及预应力混凝土桥涵设计规范》(JTGD62-2004)3.《公路工程技术标准》(JTGB01-2003)(一)技术指标设计荷载:公路Ⅰ级。
桥面宽度:0.5+11.25+0.5=12.25米,单幅桥。
标准桥面横坡:2%跨径:35米斜度:0°,10°,20°,30°,40°主梁片数:4片梁。
预制梁长:34.3米。
预制梁高:1.8米。
桥面铺装:9cm沥青混凝土。
混凝土调平层: 8cm50号混凝土。
(二)相关参数相对温度 75%桥面板与其它部分的温差为±5°预应力管道成形为钢波纹管管道摩擦系数u=0.25管道偏差系数λ=0.0025l/米钢筋回缩和锚具变形为6mm(三)主要材料1.混凝土材料预制箱梁、横隔板 50号混凝土现浇连续段、封锚端、湿接缝 50号混凝土现浇桥面层50号混凝土主梁采用50号混凝土,力学性能见表1.1混凝土力学性能表表1.12预应力筋均采用符合ASTM A416-96a标准的高强低松弛270级钢绞线,公称直径φj15.24mm,公称面积为140mm2,标准强度为MPaR by1860=,,控制张拉应力为1395MPa。
弹性模量为MPaEy51095.1⨯=。
(四)预应力布置预应力构造分为两种类型:顶板索和腹板连续索。
预制小箱梁采用OVM型锚具及配套的设备。
箱梁顶板负矩钢束采用BM15型锚具及配套的设备,管道成孔采用波纹扁管,且要求钢波纹扁管的钢带厚度不小于0.35mm。
预应力张拉采用引伸量和张拉吨位双控。
并以引伸量为主。
引伸量误差不得超过-5%~10%。
30米预应力简支箱形梁桥结构设计(迈达斯计算)
本科毕业设计题目: 30m预应力简支箱形梁桥结构设计学院: 土木工程学院专业: 土木工程(交通土建工程)班级: 1111班学号: 1vnvn学生姓名:hgjfgfh指导教师: 李建vn 职称:讲师二○一四年四月三十日30m预应力混凝土简支箱梁计算书摘要预应力混凝土简支箱梁桥以结构受力性能好、变形小、行车平顺舒适、养护工程量小、抗震能力强等而成为最富有竞争力的主要桥型之一。
预应力混凝土简支梁桥是一种预先储存了足够预加应力的新型梁桥,预加应力可大幅度提高梁体的抗裂性,并增加了梁的耐久性,截面尺寸减小,高跨比减小,受力明确,理论计算较简单,设计和施工的方法日趋完善和成熟。
简支箱形截面梁具有优良的力学特性:较大的刚度和强大的抗扭性能、结构简单、受力明确、节省材料、架设安装方便,跨越能力较大、桥下视觉效果好,因而被广泛地应用于城市桥梁和高等级公路立交桥的上部结构中。
本次设计的主要内容是关于预应力简支箱形梁桥的结构设计。
设计跨度是30m,双向四车道,桥面宽度15m(0.5m防撞墙+4×3.5m行车道+0.5m防撞墙),采用单箱双室箱形截面,桥轴线为直线,荷载等级:公路I级汽车荷载,地震设防烈度:7级。
梁高采用变高度梁,因梁桥在支点处截面的剪力过大,故在梁桥支点处选择变截面过渡,按一次曲线变化。
设计主要进行了桥梁总体布置及结构尺寸拟定、桥梁荷载内力计算、桥梁预应力钢束的估算与布置、桥梁预应力损失及应力的验算、内力组合验算、主梁截面应力验算。
利用软件Midas Civil 进行结构分析,根据桥梁的尺寸拟定建立桥梁基本模型,然后进行内力分析,计算配筋结果,进行施工各阶段分析及截面验算。
关键词:预应力混凝土、简支、箱梁、结构分析、内力验算30m prestressed concrete box girder calculationsBecause of the long-span pre-stressed concrete continuous box Girder Bridge have many advantages such as its big span ability, flexible construction methods, adaptability, structural rigidity, anti-seismic capability, Structure stress performance good, small deformation, less expansion joints, driving smooth and comfortable, beautiful forms, small maintenance quantity and etc a,it become the most competitive one of the main bridge ,and it becomes more and more widely used in China.This graduate design is mainly about the design of the superstructure of the road pre-stressed concrete Charpy Bridge. The span of the bridge is 30m. This design is a continuous bridge which has four lanes. The bridge deck is made of C50 water-protected concrete. It consists of 3.5m (the width of road deck) ×4 + 0.5m (the width of the sidewalk) ×2=15m; The axis of this bridge is a straight line, The design load standard is the Road One-Level Load,Seismic fortification intensity 7. And the height of girder is changing in the form of conic.The design of pre-stressed concrete continuous girder bridge is mainly the upper structure design , in the design of the main bridge layout and structure size, load calculation, bridge pre-stressing tendons estimation and layout ,the loss of pre-stress and stress of the bridge, the resultant checked, internal combination calculation, section stress calculation girder. This design using the Midas software analysis the structure, according to the size of the bridge, the basic model establishment bridge worked, then force analysis, calculation results of reinforced, for each phase analysis and construction. At the same time, consider the concrete shrinkage, Creep force times and temperature resultant t ime’s factors.Key word: Pre-stressed Concrete; Simple Support; Box girder; Structural Analysis; Checking the internal forces目录第一章绪论 (1)1.1概述 (1)1.2预应力梁桥受力特点 (1)1.3预应力混凝土梁桥发展综述 (2)1.3.1国外预应力混凝土梁桥的发展 (2)1.3.2国内预应力混凝土梁桥的发展 (3)1.4我国高速公路桥梁的发展 (4)1.4.1公路桥梁发展现状 (5)1.4.2我国高速公路桥梁建设特点 (5)1.5桥梁设计的基本原则 (6)1.6预应力混凝土简支梁桥的特点 (7)1.7预应力混凝土梁桥施工技术 (8)1.8毕业设计主要内容 (8)1.9毕业设计的目的和意义 (9)第二章设计要点及构造、材料、尺寸的拟定 (10)2.1桥梁选取的基本原则 (10)2.2设计的基本资料 (10)2.3箱形截面桥梁的特点 (10)2.4主要技术标准 (11)2.5主要材料及材料性能 (11)2.6设计参数取值 (11)2.7结构概述 (13)2.7.1截面形式及截面尺寸拟定 (13)2.8计算原则及控制标准 (15)第三章结构有限元模型的建造过程 (16)3.1 Midas Civil软件介绍 (16)3.2模型建立过程 (17)3.2.1设定建模环境 (17)3.2.2设置结构类型 (18)3.2.3定义材料和截面特性值 (19)3.2.4建立结构有限元模型 (21)3.2.5定义边界条件 (23)3.2.6定义荷载 (23)3.2.7定义施工阶段 (29)3.2.8汽车荷载 (29)每四章主梁作用效应计算 (32)4.1作用分类 (32)4.2公路预应力钢筋混凝土(psc)桥梁设计设计验算内容 (34)4.2.1施工阶段法向压应力验算 (34)4.2.2受拉区钢筋的接应力验算 (41)4.2.3使用阶段正截面抗裂验算 (43)4.2.4使用阶段斜截面抗裂验算 (50)4.2.5使用阶段正截面压应力验算 (55)4.2.6使用阶段斜截面主压应力验算 (60)4.2.7使用阶段正截面抗弯验算 (65)4.2.8使用阶段斜截面抗剪验算 (71)4.2.9使用阶段抗扭验算 (78)结论 (89)致谢 (90)参考文献 (91)第一章绪论1.1概述我在进行毕业设计之前,先阅读了各种文献,对桥梁的历史和发展有一个初步的了解,同时也要对桥梁结构的各种形式有系统的了解,以便今后对毕业设计有更好的把握。
大型设计院跨高速公路顶推钢箱梁midas计算书
目录1. 纵向计算 (1)1。
1概算 (1)1.2设计参数 (4)1。
2.1 结构重力 (4)1.2。
2 基础变位作用 (5)1。
2.3 汽车荷载、人群荷载 (5)1.2。
4 汽车荷载冲击力系数 (5)1。
2.5 温度作用 (5)1.2.6 抗震要求 (5)1。
2。
7 桥梁设计基准期 (5)1。
2.8 桥梁设计使用年限 (5)1.2.9 桥梁设计安全等级 (6)1.2.10 环境类别 (6)1.2。
11 材料性能 (6)1。
3计算分析 (6)1。
3.1 支承反力 (6)1。
3.2 刚度 (6)1.3.3 内力 (7)1.3.4 截面 (8)1.3。
5 应力 (9)2。
普通横隔板计算 (10)2.1计算模式 (10)2。
2截面及截面特性 (10)2。
3设计荷载 (10)2.3.1 结构重力 (10)2。
3。
2 汽车荷载 (11)2。
4强度检算 (11)2。
5稳定检算 (12)3。
中支点横隔板 (12)3.1计算模式 (12)3.2强度检算 (12)3。
3稳定检算 (13)4. 端支点横隔板 (13)4。
1计算模式 (13)4。
2强度检算 (14)4。
3稳定检算 (15)5。
左侧悬臂托架 (15)5。
1计算模式 (15)5.2截面及截面特性 (16)5。
3设计荷载 (16)5。
3。
1 结构重力 (16)5。
3.2 汽车荷载 (17)5。
4内力 (17)5.5强度检算 (17)5。
5。
1 正应力 (18)5.5。
2 剪应力 (18)5。
5。
3 稳定检算: (18)6. 右侧悬臂托架 (18)6。
1计算模式 (18)6.2截面及截面特性 (18)6.3设计荷载 (19)6.3。
1 结构重力 (19)6.3.2 汽车荷载 (20)6.4内力 (20)6。
5强度检算 (20)6.5.1 正应力 (20)6.5.2 剪应力 (21)6。
5.3 稳定检算: (21)7. 支承加劲肋检算 (21)7。
1计算模式 (21)7.2强度核算 (21)7。
30米预应力简支箱形梁桥结构设计(迈达斯计算)
本科毕业设计题目: 30m预应力简支箱形梁桥结构设计学院: 土木工程学院专业: 土木工程(交通土建工程)班级: 1111班学号: 1vnvn学生姓名:hgjfgfh指导教师: 李建vn 职称:讲师二○一四年四月三十日30m预应力混凝土简支箱梁计算书摘要预应力混凝土简支箱梁桥以结构受力性能好、变形小、行车平顺舒适、养护工程量小、抗震能力强等而成为最富有竞争力的主要桥型之一。
预应力混凝土简支梁桥是一种预先储存了足够预加应力的新型梁桥,预加应力可大幅度提高梁体的抗裂性,并增加了梁的耐久性,截面尺寸减小,高跨比减小,受力明确,理论计算较简单,设计和施工的方法日趋完善和成熟。
简支箱形截面梁具有优良的力学特性:较大的刚度和强大的抗扭性能、结构简单、受力明确、节省材料、架设安装方便,跨越能力较大、桥下视觉效果好,因而被广泛地应用于城市桥梁和高等级公路立交桥的上部结构中。
本次设计的主要内容是关于预应力简支箱形梁桥的结构设计。
设计跨度是30m,双向四车道,桥面宽度15m(0.5m防撞墙+4×3.5m行车道+0.5m防撞墙),采用单箱双室箱形截面,桥轴线为直线,荷载等级:公路I级汽车荷载,地震设防烈度:7级。
梁高采用变高度梁,因梁桥在支点处截面的剪力过大,故在梁桥支点处选择变截面过渡,按一次曲线变化。
设计主要进行了桥梁总体布置及结构尺寸拟定、桥梁荷载内力计算、桥梁预应力钢束的估算与布置、桥梁预应力损失及应力的验算、内力组合验算、主梁截面应力验算。
利用软件Midas Civil 进行结构分析,根据桥梁的尺寸拟定建立桥梁基本模型,然后进行内力分析,计算配筋结果,进行施工各阶段分析及截面验算。
关键词:预应力混凝土、简支、箱梁、结构分析、内力验算30m prestressed concrete box girder calculationsBecause of the long-span pre-stressed concrete continuous box Girder Bridge have many advantages such as its big span ability, flexible construction methods, adaptability, structural rigidity, anti-seismic capability, Structure stress performance good, small deformation, less expansion joints, driving smooth and comfortable, beautiful forms, small maintenance quantity and etc a,it become the most competitive one of the main bridge ,and it becomes more and more widely used in China.This graduate design is mainly about the design of the superstructure of the road pre-stressed concrete Charpy Bridge. The span of the bridge is 30m. This design is a continuous bridge which has four lanes. The bridge deck is made of C50 water-protected concrete. It consists of 3.5m (the width of road deck) ×4 + 0.5m (the width of the sidewalk) ×2=15m; The axis of this bridge is a straight line, The design load standard is the Road One-Level Load,Seismic fortification intensity 7. And the height of girder is changing in the form of conic.The design of pre-stressed concrete continuous girder bridge is mainly the upper structure design , in the design of the main bridge layout and structure size, load calculation, bridge pre-stressing tendons estimation and layout ,the loss of pre-stress and stress of the bridge, the resultant checked, internal combination calculation, section stress calculation girder. This design using the Midas software analysis the structure, according to the size of the bridge, the basic model establishment bridge worked, then force analysis, calculation results of reinforced, for each phase analysis and construction. At the same time, consider the concrete shrinkage, Creep force times and temperature resultant t ime’s factors.Key word: Pre-stressed Concrete; Simple Support; Box girder; Structural Analysis; Checking the internal forces目录第一章绪论 (1)1.1概述 (1)1.2预应力梁桥受力特点 (1)1.3预应力混凝土梁桥发展综述 (2)1.3.1国外预应力混凝土梁桥的发展 (2)1.3.2国内预应力混凝土梁桥的发展 (3)1.4我国高速公路桥梁的发展 (4)1.4.1公路桥梁发展现状 (5)1.4.2我国高速公路桥梁建设特点 (5)1.5桥梁设计的基本原则 (6)1.6预应力混凝土简支梁桥的特点 (7)1.7预应力混凝土梁桥施工技术 (8)1.8毕业设计主要内容 (8)1.9毕业设计的目的和意义 (9)第二章设计要点及构造、材料、尺寸的拟定 (10)2.1桥梁选取的基本原则 (10)2.2设计的基本资料 (10)2.3箱形截面桥梁的特点 (10)2.4主要技术标准 (11)2.5主要材料及材料性能 (11)2.6设计参数取值 (11)2.7结构概述 (13)2.7.1截面形式及截面尺寸拟定 (13)2.8计算原则及控制标准 (15)第三章结构有限元模型的建造过程 (16)3.1 Midas Civil软件介绍 (16)3.2模型建立过程 (17)3.2.1设定建模环境 (17)3.2.2设置结构类型 (18)3.2.3定义材料和截面特性值 (19)3.2.4建立结构有限元模型 (21)3.2.5定义边界条件 (23)3.2.6定义荷载 (23)3.2.7定义施工阶段 (29)3.2.8汽车荷载 (29)每四章主梁作用效应计算 (32)4.1作用分类 (32)4.2公路预应力钢筋混凝土(psc)桥梁设计设计验算内容 (34)4.2.1施工阶段法向压应力验算 (34)4.2.2受拉区钢筋的接应力验算 (41)4.2.3使用阶段正截面抗裂验算 (43)4.2.4使用阶段斜截面抗裂验算 (50)4.2.5使用阶段正截面压应力验算 (55)4.2.6使用阶段斜截面主压应力验算 (60)4.2.7使用阶段正截面抗弯验算 (65)4.2.8使用阶段斜截面抗剪验算 (71)4.2.9使用阶段抗扭验算 (78)结论 (89)致谢 (90)参考文献 (91)第一章绪论1.1概述我在进行毕业设计之前,先阅读了各种文献,对桥梁的历史和发展有一个初步的了解,同时也要对桥梁结构的各种形式有系统的了解,以便今后对毕业设计有更好的把握。
迈达斯简支小箱梁计算书
修改最终版_restore计算书设计:_____________________校对:_____________________审核:_____________________2015-5-12目录一、基本信息 (3)1.1 工程概况 (3)1.2 技术标准 (3)1.3 主要规范 (3)1.4 结构概述 (3)1.5 主要材料及材料性能 (3)1.6 计算原则、内容及控制标准 (4)二、模型建立与分析 (4)2.1 计算模型 (4)2.2 主要钢筋布置图及材料用表 (5)2.3 截面特性及有效宽度 (5)2.4 荷载工况及荷载组合 (6)三、内力图 (8)3.1 内力图 (9)四、持久状况承载能力极限状态验算结果 (9)4.1 截面受压区高度 (9)4.2 正截面抗弯承载能力验算 (9)4.3 斜截面抗剪承载能力验算 (10)4.4 抗扭承载能力验算 (10)4.5 支反力计算 (11)五、持久状况正常使用极限状态验算结果 (12)5.1 结构正截面抗裂验算 (12)5.2 结构斜截面抗裂验算 (13)六、持久状况构件应力验算结果 (13)6.1 正截面混凝土法向压应力验算 (13)6.2 正截面受拉区钢筋拉应力验算 (14)6.3 斜截面混凝土的主压应力验算 (14)七、短暂状况构件应力验算结果 (15)7.1 短暂状况构件应力验算 (15)一、基本信息1.1 工程概况1.2 技术标准1.3 主要规范1)《公路钢筋混凝土及预应力混凝土桥涵设计规范》(JTG D62-2004)2)《公路桥涵设计通用规范》(JTG D60-2004)3)《公路工程技术标准》(JTG B01-2003)4)《公路桥梁抗震设计细则》(JTG/T B02-01-2008)5)《公路桥涵地基与基础设计规范》(JTG D63-2007)6)《城市桥梁设计规范》(CJJ11-2011)1.4 结构概述1.5 主要材料及材料性能1)混凝土表格 1 混凝土表格2)普通钢筋表格 2 普通钢筋表格3)预应力材料表格 3 预应力材料表格1.6 计算原则、内容及控制标准计算书中将采用midas Civil对桥梁进行分析计算,并以《公路桥涵设计通用规范》(JTG D60-2004)和《公路钢筋混凝土及预应力混凝土桥涵设计规范》(JTG D62-2004)为标准,按A类预应力混凝土结构进行验算。
midas--预应力混凝土连续梁桥设计1+RC设计验算说明
MIDAS Information Technology(Beijing) Co., Ltd
概要
本例题使用一个简单的预应力混凝土两跨连续梁箱模型(图1)来重点介 绍MIDAS/Civil 2006 软件的新增功能,PSC桥梁建模助手、横向分析、任意 截面显示等的输入方法。
图1. 分析模型
2
MIDAS Information Technology(Beijing) Co., Ltd
模型>单元> 扩展单元
全选
扩展类型>节点 Æ线单元
单元类型>梁单元 ; 材料>1:C50 ; 截面> 1: span
生成形式>复制和移动
复制和移动>等间距>dx,dy,dz>(2, 0, 0)
复制次数>(60) ↵
模型>单元>复制和移动
单选 (节点:31)
等间距>dx,dy,dz>(0,0,-7.13)
3.500 450 1.750
12.700 500
1.350 1.350
3.500 1.750
2.000 600 450 1.750 1.050
CL OF BOX
275 250
325 250
275 250 260 1.840 350 80 2.700 250
250350 802源自05.680850
450 1.250
同时定义多种材料
特性时,使用 键可以连续输入。
下面定义PSC Beam所使用的混凝土和钢束的材料特性。
模型 / 材料和截面特性 / 材料 类型>混凝土 ; 规范> JTG04(RC) 数据库> C50 ↵
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
连续箱梁挂蓝计算书(midas)(2009-07-04 11:47:42)
一、工程简介
主桥上部结构为32+68+32m三跨预应力混凝土连续箱梁,梁体自重γ取26kN/m3,跨端支座处、边垮直线段和跨中处梁高为2.8m,中支点处梁高为3.4m,梁高按圆曲线变化,圆曲线半径R=367.80m,顶板厚34cm,腹板厚分别为40cm和70cm,底板厚度由跨中的30cm按圆曲线变化至中点梁根部的60cm,中点处加厚到110cm。
节段主要参数如下表所示:
由于0#块长度不够,1#选用整体挂篮施工(见设计图),荷载采用最重悬浇箱梁段A1段:90.0吨。
二、挂篮主要技术标准及参考资料
1、参考《公路桥涵施工技术规范》规定,各设计参数取值如下:
(1)挂篮质量控制在浇筑梁段砼质量的0.3~0.5倍之间。
(2)允许最大变形(包括吊带变形的总和):20mm
(3)施工及行走时抗倾覆安全系数:2.5
(4)自锚固系统的安全系数:2
2、参考资料
(1)、通桥2008-2261A-V;
(2)、《路桥施工计算手册》-人们交通出版社;
(3)、《简明施工计算手册》-中国建筑工业出版社;
(4)、《悬臂浇注预应力混凝土梁桥》-人们交通出版社;
(5)、本挂篮采用的设计规范有:
1)《铁路桥梁钢结构设计规范》(TB10002.2-2005);
2)《铁路桥涵钢筋混凝土和预应力混凝土设计规范》(TB10002.3-2005);3).《钢结构设计规范》(GB50017-2003);
4).《铁路桥涵设计基本规范》(TB10002.1-2005)。
3、主要材料的力学指标
(1)、Q235(A3钢),屈服应力,,弹性模量;
(2)、20CrMnTi,屈服应力,弹性模量。
三、结构分析及计算参数
1、结构受力分析
根据悬灌梁段的实际情况,挂篮分以下三种工况进行受力检算:
(1)、工况一:1#梁段施工时连体挂篮的强度检算;
(2)、工况二:2#梁段施工时挂篮的强度检算
(2)、工况三:挂篮挠度验算;
(3)、工况四:挂篮走行时抗倾覆计算。
2、作用于挂篮的主要荷载
参考《路桥施工计算手册》箱梁荷载取值如下:
荷载集中 (KN) 梁单元
(KN)
楼板 (KN) 压力 (KN) 自重 (KN) 合计 (KN)
底模混凝土0.00E+00 -5.34E+01 0.00E+00 0.00E+00 0.00E+00 -5.34E+01 内模混凝土0.00E+00 -3.51E+01 0.00E+00 0.00E+00 0.00E+00 -3.51E+01 外模混凝土0.00E+00 -1.81E+01 0.00E+00 0.00E+00 0.00E+00 -1.81E+01 输出荷载统计
集中 (KN) 梁单元
(KN)
楼板 (KN) 压力 (KN) 自重 (KN) 合计 (KN)
0.00E+00 -1.07E+02 0.00E+00 0.00E+00 0.00E+00 -1.07E+02
(1)、浇注箱梁的重量同时考虑动力系数1.2、胀模超载系数1.05;混凝土重量分底板、翼板、顶板混凝土考虑。
底板混凝土重量加载在底纵梁上;翼板混凝土重量加载在外滑梁上;顶板混凝土重量加载在内滑梁上。
输入荷载如下表:
(2)、施工人员及机具重量按2.5kpa计算;
(3)、模板及支架重量,按实际情况取值。
梁内模重2.50t,外模重7.0t,外滑梁重3.5t 按实际情况加载。
(5)、挂篮走行时考虑冲击荷载,取冲击系数为1.3;
(6)、抗倾覆稳定系数2。
3、荷载组合
(1)、组合一:混凝土重量+动力附加荷载+挂篮自重+施工人员及机具荷载;
(2)、变形组合二:混凝土重量+挂篮自重+风载;
(3)、走行组合三:挂篮自重+挂篮移动时的冲击荷载+风荷载。
四、 68m梁挂篮结构模型
按空间结构分别建立挂篮浇筑砼时、走行时的模型,全部采用梁单元,根据实际工况对部分单元采用了刚性连接和释放端部约束,并添加实际工况荷载。
1#块施工强度及变形验算模型2#块施工强度及变形验算模型
走行时外滑梁受力计算模型
五、抗倾覆验算
倾覆力矩:
抗倾覆力矩
抗倾覆安全系数
,压重至少为46t,走行时每组轨道至少使用3组分配梁和6根精轧螺纹钢锚固,每根按5t计,等效于压重60t>46t。
六、68m梁挂篮受力及变形计算
1、挂篮内力图
强度变形验算轴力图强度变形验算弯矩图
强度变形验算剪力图走行时轴力图
走行时弯矩图
走行时剪力图
2.挂篮主要杆件内力计算成果汇总表:
杆件名称规格型号荷载组
合
最大弯距
(KN*M)
最小弯距
(KN*M)
轴力(KN) 剪力(KN)
主桁前横梁2I40a 组合一111.2 -192.87 214.17
主桁纵梁2[32 组合一8.77 -49.93 -580.07 84.23 主桁立柱2[32 组合一-784.54
斜拉带2[32 组合一697.86
后锚杆φ32组合一214.94
吊杆φ32组合一159.25
底模横梁2I32a 组合一71.08 64.14 -153.16 底模纵梁I28a 组合一69.79 -1.44 61.69 底模双根纵梁2I28a 组合一107.48 -0.9 81.66
外模滑梁2I28a 走行组
合
142.51 42.35
内滑梁2I28a 组合一71.51 19.31 69.39
3.挂篮计算成果分析
(1)主桁纵梁
主桁纵梁采用[]32a:
弯应力:
压应力:
剪应力:
结构变形:最大挠度-5.15mm,累计位移11.642mm。
螺栓连接的强度验算单个螺栓: d=27mm
因为:
取整齐排列的螺栓数N=16 (偏安全)
对于单个螺栓
满足强度要求 .
(2)斜拉带
斜拉带采用[]32a,主要受轴力,正应力验算:
斜拉带在穿孔处验算,
钢销采用20CrMnTi,直径为100mm验算。
主要承受剪力,。