Project No. 100291201SAT-004G March 14, 2011 Schneider Electric Asia Pacific Limited Page 2 of 6
ABSTRACT
Specimen I. D. “ACTND04LS”
Description: The specimen was 5.1mm in diameter and consisted of fiber optical conductors insulated in a yellow jacket.
International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric
Cables Under Fire Conditions, Part 3-24: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables, Category C, Edition 1.1, 2009-02.
Category C - The number of test pieces required to provide a nominal total volume of non-metallic material of 1.5 liters per meter.
The test flame was supplied by means of a 250-mm wide, 11-55 drilling ribbon-type burner, and an air/gas Venturi mixer (catalog no. 14-18) manufactured by the American Gas Furnace Company. The burner was mounted horizontally 600 mm from the bottom of the cable tray. The burner is located so that the flame impinges on the specimen midway between the tray rungs and 75 mm from the closest surface of the test specimen.
III TEST PROCEDURE
The test specimen comprises a number of test pieces from the same sample, each having a minimum length of 3.5 m. The total number of 3.5-m test pieces in the test specimen is in accordance with one of three categories as follows:
Test Standard: International Electrotechnical Commission (IEC) Technical Report 60332-3-10, Tests on Electric Cables Under Fire Conditions, Part 3-10: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables – Apparatus, First Edition, 2000-10.
RENDERED TO:
Schneider Electric Asia Pacific Limited 13th Floor, East Wing, Warwick House Taikoo Place, 979 King's Road QUARRY BAY, HONG KONG ZJHZ 100016 CHINA
Component Length (cm) Weight (g) Density (g/cc) Volume (cc) Outer Jacket 50 10 1.52 6.579 Inner Jacket 50 0 0 0.000 Ripcord 50 0 0 0.000 Aramid Yarn 50 0.85 1.44 0.590 Nylon Buffer 50 0 0 0.000 Inner Layer Buffer 50 1.51 1.35 1.119
Optical Fiber 50 0.15 1.527 0.098 Total/50 cm 12.51 8.386 Total/meter 25.02 1百度文库.772 Whole Cable per meter 50 13 26 1.224 10.621 21.242
89 = # of cable length to give 1.5L Combustible material 1335 = Length (ft) to be submitted for one test 406.9 = Length (m) to be submitted for one test
Report of Testing “ACTND04LS” for compliance with the applicable requirements of the following criteria: International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric Cables Under Fire Conditions, Part 3-24: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables, Category C, Edition 1.1, 2009-02.
The specimens were received March 3, 2011 in good condition, prepared, and test evaluations were conducted at Intertek, Elmendorf, Texas.
Project No. 100291201SAT-004G March 14, 2011 Schneider Electric Asia Pacific Limited Page 4 of 6
Project No. 100291201SAT-004G March 14, 2011 Schneider Electric Asia Pacific Limited Page 3 of 6
I SPECIMEN DESCRIPTION
The test was performed on a sample identified by the client as “ACTND04LS”. The specimen was a fiber optic conductor cable insulated in a yellow jacket.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of the report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
The flow of air to the Venturi mixer was controlled at the rate of 76.7 l/min ± 4.7 l/min. The propane flowing to the Venturi mixer was controlled at the rate of 13.3 l/min ± 0.5 l/min using gas with a nominal heating value of 2500 Btu (thermochemical) per cubic foot (93 MJ/m3).
TEST REPORT
AUTHORIZATION OF TEST
Mr. Ken Kwan, representing the client, Schneider Electric Asia Pacific Limited, authorized the test under Quote No. 500269849.
Test Date: March 14, 2011
Client: Schneider Electric Asia Pacific Limited
Test Results: RESULT: PASS
* Refer to page 4 of report for further details on results.
Specific gravity sheet was submitted to Intertek by Ken Kwan, a representative of Schneider Electric Asia Pacific Limited.
II INTRODUCTION
This report describes the results of the International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric Cables under Fire Conditions performed on samples submitted by Schneider Electric Asia Pacific Limited and previously described.
60332-3-24 Intertek Report
报告内容: Page 1 of 6
REPORT NUMBER: 100291201SAT-004G ORIGINAL ISSUE DATE: March 14, 2011 REVISED DATE: N/A
EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112
ABSTRACT
Specimen I. D. “ACTND04LS”
Description: The specimen was 5.1mm in diameter and consisted of fiber optical conductors insulated in a yellow jacket.
International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric
Cables Under Fire Conditions, Part 3-24: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables, Category C, Edition 1.1, 2009-02.
Category C - The number of test pieces required to provide a nominal total volume of non-metallic material of 1.5 liters per meter.
The test flame was supplied by means of a 250-mm wide, 11-55 drilling ribbon-type burner, and an air/gas Venturi mixer (catalog no. 14-18) manufactured by the American Gas Furnace Company. The burner was mounted horizontally 600 mm from the bottom of the cable tray. The burner is located so that the flame impinges on the specimen midway between the tray rungs and 75 mm from the closest surface of the test specimen.
III TEST PROCEDURE
The test specimen comprises a number of test pieces from the same sample, each having a minimum length of 3.5 m. The total number of 3.5-m test pieces in the test specimen is in accordance with one of three categories as follows:
Test Standard: International Electrotechnical Commission (IEC) Technical Report 60332-3-10, Tests on Electric Cables Under Fire Conditions, Part 3-10: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables – Apparatus, First Edition, 2000-10.
RENDERED TO:
Schneider Electric Asia Pacific Limited 13th Floor, East Wing, Warwick House Taikoo Place, 979 King's Road QUARRY BAY, HONG KONG ZJHZ 100016 CHINA
Component Length (cm) Weight (g) Density (g/cc) Volume (cc) Outer Jacket 50 10 1.52 6.579 Inner Jacket 50 0 0 0.000 Ripcord 50 0 0 0.000 Aramid Yarn 50 0.85 1.44 0.590 Nylon Buffer 50 0 0 0.000 Inner Layer Buffer 50 1.51 1.35 1.119
Optical Fiber 50 0.15 1.527 0.098 Total/50 cm 12.51 8.386 Total/meter 25.02 1百度文库.772 Whole Cable per meter 50 13 26 1.224 10.621 21.242
89 = # of cable length to give 1.5L Combustible material 1335 = Length (ft) to be submitted for one test 406.9 = Length (m) to be submitted for one test
Report of Testing “ACTND04LS” for compliance with the applicable requirements of the following criteria: International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric Cables Under Fire Conditions, Part 3-24: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables, Category C, Edition 1.1, 2009-02.
The specimens were received March 3, 2011 in good condition, prepared, and test evaluations were conducted at Intertek, Elmendorf, Texas.
Project No. 100291201SAT-004G March 14, 2011 Schneider Electric Asia Pacific Limited Page 4 of 6
Project No. 100291201SAT-004G March 14, 2011 Schneider Electric Asia Pacific Limited Page 3 of 6
I SPECIMEN DESCRIPTION
The test was performed on a sample identified by the client as “ACTND04LS”. The specimen was a fiber optic conductor cable insulated in a yellow jacket.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of the report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
The flow of air to the Venturi mixer was controlled at the rate of 76.7 l/min ± 4.7 l/min. The propane flowing to the Venturi mixer was controlled at the rate of 13.3 l/min ± 0.5 l/min using gas with a nominal heating value of 2500 Btu (thermochemical) per cubic foot (93 MJ/m3).
TEST REPORT
AUTHORIZATION OF TEST
Mr. Ken Kwan, representing the client, Schneider Electric Asia Pacific Limited, authorized the test under Quote No. 500269849.
Test Date: March 14, 2011
Client: Schneider Electric Asia Pacific Limited
Test Results: RESULT: PASS
* Refer to page 4 of report for further details on results.
Specific gravity sheet was submitted to Intertek by Ken Kwan, a representative of Schneider Electric Asia Pacific Limited.
II INTRODUCTION
This report describes the results of the International Electrotechnical Commission (IEC) Technical Report 60332-3-24, Tests on Electric Cables under Fire Conditions performed on samples submitted by Schneider Electric Asia Pacific Limited and previously described.
60332-3-24 Intertek Report
报告内容: Page 1 of 6
REPORT NUMBER: 100291201SAT-004G ORIGINAL ISSUE DATE: March 14, 2011 REVISED DATE: N/A
EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112