54Digital LEDBar-graph LEDDual monitoring systemThe FS-V10 Series features both a digital LED indicator, whichnumerically displays the received light intensity, and a bar LED, which shows the level of detectionDescriptionFeaturesq An Industry-first dual monitoring system q Auto and manual calibrationq 20-bit concurrent processing chip q High accuracy and high powerqWire-saving 0-line or 1-line connection systemDetecting DistanceThrubeam – Up to 3,600 mm (with lens)Diffuse-reflective – Up to 300 mmDefinite-reflective – Up to 14 mmAutomatic SET buttonFS01SeriesHigh AccuracyFibreoptic Sensors<FS-V10 Series>NEW 20-bit concurrentprocessing chip + 12-bit A/D converter The FS-V10 Series features a newlydeveloped 20-bit concurrent processing chip.This chip can concurrently process12 types of control including calculation of received light intensity “dual monitor display ”, and hold display ”. Compared to general-purposeHigh Accuracy Fibreoptic SensorsAmplifier VariationsHybrid Calibration Type:FS-V10 Series•Dual monitoring function withbar LED and digital display•Hybrid calibration with Auto SETbutton and manual adjustmentbuttonOne-touch Calibration Type:FS-T Series•Fully-automatic calibration byDetects down to 0.01 mm dia wire withDetects target at the industry longestHigh Accuracy Fibreoptic SensorsSUPER TURBO ModeTURBO Mode200 mm300 mmFINE Mode100 mmModel: FU-66From ultra-high precision to ultra-high power:A single unit covers every applicationThe FS-V10 Series offers three levels of detection to Small targetReceived light quantity: LargeLarge targetReceived light quantity: SmallArea detection fibre unitHigh Accuracy Fibreoptic SensorsUnstable operating conditions can be discovered at a glance using Bar LED indicatorsThe bar LED indicates detection stability using a 7-level bar LED.The bar LED shows when maintenance is required at a glance, which is difficult to notice with the digital display.Low excess gainOne LED does not lightduring light beam reception.1-line systemSpace advantageHigh Accuracy Fibreoptic Sensors)l a t i g i d ,l a u n a m +h c u o t -e n O (n o i t a r b i l a c d i r b y H ti n u n i a M ti n u n o i s n a p x e e n i l -1ti n u n o i s n a p x e e n i l -011V -S F 21V -S F 01V -S F .1P11V -S F P21V -S F —DE L d e R )O B R U T R E P U S (s m 1/)O B R U T (s µ005/)E N I F (s µs m 7.1o t s µ014.2)e l b a t c e l e s -h c t i w s (N O -K R A D /N O -T H G I LHigh Accuracy Fibreoptic Sensorsno i t a r b i l a c l a u n a M t i n u n i a M ti n u n o i s n a p x e e n i l -1es n o p s e r d e e p s -h g i H ti n u n o i s n a p x e e n i l -01M -S F 2M -S F H1M -S F 0M -S F P 1M -S F P 2M -S F ——DE L d e R DE L d e R DE L d e R DE L d e R )e l b a t c e l e s -h c t i w s (O B R U T /E N I F ,)r o t a c i d n i h t i w (r e m m i r t n r u t -8,)E N I F (s µ052)O B R U T (s µ005,)E N I F (s µ052)O B R U T (s µ005,)E N I F (s µ02)O B R U T (s µ05s m 2.1o t s µ014.1.x a m x u l 000,02:t h g i l n u S ,.x a m x u l 000,01:p m a l t n e c s e d n a c n I 55+o t 01-°C55+o t 01-°C55+o t 01-°C55+o t 01-°Ce t a n o b r a c y l o P :r e v o C e t a n o b r a c y l o P :r e v o C /y d o B e t a n o b r a c y l o P :r e v o C /y d o B et a n o b r a c y l o P :r e v o C /y d o B g57.x o r p p A g04.x o r p p A g02.x o r p p A g02.x o r p p A The response speed varies depending on the number of expansion units connected.Only the FS-T1/M1 provide stability outputs. Stability outputs for the FS-T2/T0/M2/M0 are output from the FS-T1/M1 or FS-R0.Power to the FS-T2/T0/M2/M0 is supplied through the FS-V11/V1/T1/M1 or FS-R0.1-line connection amplifiers reduce wiring Up to 16 expansion units can be connected to a single main unit and can be freely combined.Expansion units+FS-T1G :Green LED light source FS-M1H :High-speed response FS-V12:Hybrid calibration FS-T2:One-touch calibration FS-M2:Manual calibration FS-R0FS-T0FS-M0Connector unit0-lineexpansion-units0-line connection units eliminate wiring and labourThe innovative 0-line connection system only requires an FS-R0 connector unit and a cable with a MIL connector for wiring. The units can be easily connected to an I/O card of a PLC (programmable controller) or special board. Units can be freely combined to suit the application.Board InputDC power supplyPLC Cable with MIL connectorFS-V10Terminal block unitHigh Accuracy Fibreoptic SensorsFU-77FU-67FU-66ZFU-63ZFU-35FZFU-12A single-core fibre exposed to excessive bending will easily break.The 217-core fibre is hardly affected by exces-sive bending.Ready for immediate useArmoured ToughFlexprovides a cost and labour savings by eliminating the need for protective tubing.More flexible than conventional spiral fibresToughFlex will not break even when sharply bent.More flexible than conventional spiral fibres.Standard FibreToughFlex Fibre PrincipleKeyence has developed the toughest fibre unit series by bundling multiple core fibres of 66 µm diameter. These fibres will work normally without any malfunction even when they are bent to a minimum radius or when they are Keyence has also maintained a long detecting distance while using this unique design. Including focused small spot model, area detection model, ultra-long detecting distance model, and thin sleeve models, every application can be improved with maintenance efficiency.Plus, the latest armoured model is sheathed by a flexible stainless steel jacket to protect the fibre from daily wear ToughFlex fibre variationsToughFlex Fibre FeaturesT oughFlex will not break even when sharply bent.FU-67G/77GHigh Accuracy Fibreoptic Sensors FS01ToughFlex Fibres [Patent pending]:FU-67/77/35FZ/4FZ/5FZ/63Z/66Z/12Fibres with a minimum bend radius of 2 mm retain light intensity even when folded. These innovative fibres can be routed just like an electric wire, enabling installation anywhere.High-flex Fibres: FU-45X/48/49X/59/65X/68/69X/78/79 These fibres, which provide higher flexibility than an electric wire, can endure repeated bends. The bendradius of 4 mm makes fibre routingeasier and saves mountingspace.Compact Definite Reflective Fibres: These fibres are excellent for detection in tight spaces such as being embedded in a robot arm or on a conveyor. Detection is almost unaffected by target backgrounds.Area Detection Fibre: FU-12The FU-12, which provides a detecting area 10 mm wide, is suitable for detecting vibrating targetsor minute targets. A target assmall as 1.2 mm in diametercan be accurately detected.Fibre Unit Selection Guide (major models only)High Accuracy Fibreoptic SensorsFeaturesDetecting distance 1. (mm)Smallest 2. detectable object Minimum bend radius640760(3600)320ø0.03 mmø0.03 mmR25 mmR4 mmLong-detecting distanceA minimum bend radius of 4 mm300370150Lens F-1, F-2, F-4Lens F-1, F-2, F-4Fibre Unit Selection ChartHigh Accuracy Fibreoptic SensorsFeaturesDetecting distance 1. (mm)Smallest 2.detectable object Minimum bend radiusModel Weight(Approx.)2003001001602408020281270110ø0.01 mm (gold wire)R25 mmSuitable for positioning0.2 mm spot diameter when used with F-2HA 0.4 mm spot diameter when 4g18g4g 6g Free-cutFree-FU-23X FU-25FU-21XFU-35FALens F-2HALensHigh Accuracy Fibreoptic SensorsFeaturesDetecting distance 1. (mm)Smallest 2.detectable object Minimum bend radius3 (Centre of detecting distance)3 (Centre of detecting distance)3 (Centre of detecting distance)6 ±16 ±16 ±10 to 40 to 40 to 40 to 14 (Centre of detecting distance)0 to 14 (Centre of detecting distance)ø0.3 mm (gold wire)ø0.08 mm (copper wire)R25 mmR10 mmø0.01 mm (gold wire)Almost unaffected by target colour and backgroundAlmost unaffected by target background, side-by-sidedetection available Almost unaffected by target colour and background, long-High Accuracy Fibreoptic Sensorsdr a d n a t S tn a t s i s e r -t a e H ,f o o r p l i O fo o r p l a c i m e h C 053°ep y t C 003°ep y t C 081°ep y t C 501°ep y t C 07+o t 04-°C :77,76,21-U F (05+o t 04-°,C :93-U F 001+o t 03-°)C 053+o t 03-°C .1003+o t 04-°C .1081+o t 06-°C .1501+o t 04-°C 07+o t 03-°C,c i t s a l P :e r b i F :h t a e h S e n e l y h t e y l o P )s s a l g :93-U F (,s s a l G :e r b i F la r i p s l e e t s -s s e l n i a t S :h t a e h S eb u t ,c i t s a l P :e r b i F :h t a e h S no b r a c o r o u l F gn i t a o c r e m y l o p ,c i t s a l P :e r b i F :h t a e h S en e l y p o r p y l o P ,c i t s a l P :e r b i F n o l f e T :h t a e h S1. Ambient temperature varies depending on the distance from the tip or a fibre unit. Refer to "Dimensions". The ambient temperature for the FU-87 and 88 is in dry condition.ConfigurationFeature Model FINE TURBO SUPERTURBO ModelDetecting distance (mm)Applicable fibre units FU-35FA(Z)FU-35FA(Z)FU-7F,8640026022022018008005404404403600100067055055036002.FU-77, 77G FU-78FU-84CFU-7F,860 to 20 with beam spotdiameter of 4 mm15 ±2 with beam spot diameter of 0.5 mmImproves the stability for the minute target detection.Space-saving, side-view type F-3HAF-4HAF-11.NEW When using the F-1 at a temperature of 70°C or more, specify the "Heat-resistant F-1"."3600" is assumed as maximum because the fibre cable has the length of 2 m.High Accuracy Fibreoptic Sensors190120501601004565ShapeDetecting distance 1. (mm)3 mm dia.M41.5 mm dia.M43 mm dia.Detecting distance using FS-T1G/FS-M1H Fibre Unit Selection ChartHigh Accuracy Fibreoptic SensorsFS01ec n a t s id g n i t ce t e d -g n o l -a r t l U s n e l g n i s u c o F 4-F A H 2-F AH 3-F 68,F 7-U F G77,77-U F AF 53-U F 00310001802001200610103006005851we i v -e d i S ec n a t s id g n i t ce t e d -g n o L 1-F 2-F 68,F 7-U F .1G77,77-U F C 48-U F .168,F 7-U F G77,77-U F C 48-U F 061021001008006005052022061003100010080705540040530520R -S F .x a m ,%5±C D V 42o t 21.1t n e r r u c s u l p ,s s e l r o A m 02st i n u n o i s n a p x e y b d e m u s n o c de t c e n n o c )t u p t u o y t i l i b a t s g n i s u n e h w 51(661s m 2.1o t s µ014.2).x a m V 04(.x a m A m 05N P N l e d o M 3R -S F y l p p u s r e w o P .x a m %5±C D V 42o t 21.1n o i t p m u s n o c t n e r r u C yb d e m u s n oc t n e r r u c s u l p ,s s e l r o A m 05).x a m A m 001(r o s n e s d e t c e n n o c s t u p n i e l b a d n a p x E 2l a n g i s t u p n I t u p n i e g a t l o v -n o n P N P /N P N gn i h c t i w s )e t a t s -d i l o s ,t c a t n o c (e m i t e s n o p s e R s m 1o t s µ053.2ed o m t u p t u O )e l b a t c e l e s -h c t i w s (.C .N /.O .N Attachment (with FS-M1H/T1G)1. To use the F-1 with the FU-84C or FU-86, specify the heat-resistant F-1 when ordering.Simple wiring connector unitTerminal block unitHigh Accuracy Fibreoptic SensorsInput/Output CircuitsP h o t o e l e c t r i c s e n s o r m a i n c i r c u i tInput circuitBrownBlack(Control output)(Stability output)Orange1.BluePink2.(External calibration)O v e r c u r r e n t p r o t e c t i o n c i r c u i tLoad100 mA max.Load 50 mA max.12 to 24 VDCFS-T1/M1/T1G/M1HP h o t o e l e c t r i c s e n s o r m a i n c i r c u i tInput circuitO v e r c u r r e n t p r o t e c t i o n c i r c u i t12 to 24 VDCFS-V11.When the stability output is not used, cut the orange cable at the base, or connect this cable to the 0 V terminal of the power supply.High Accuracy Fibreoptic SensorsMODEMODEPress this button once.Received light intensityExcess gain display (%)Press this button once.Display changes alternately.Hold display (Excess gain)R e c e i v e d l i g h t i n t e n s i t yMax.Setting value*Min.TimeSelecting displayed dataThe display changes every time the MODE button is Setting the sensitivity (Automatic calibration)Select the sensitivity setting procedure according to the target condition.When the setting is completed, the setting value flashes twice.For sensitivity adjustment using a moving target • Fully-automatic calibration1.Pass a target through theoptical axis while pressing the SET button.2.The calibration indicator (orange LED) flashes.3.Release the SET button. (The orange LED goes off.)*The setting value is adjusted to the midpoint of the difference between the maximum andHigh Accuracy Fibreoptic SensorsUP DOWNPress or once.Flashing displayWait for 2 seconds.At least 3 seconds120PA Changing the setting value When the sensitivity difference is insufficientIf the sensitivity has no allowance, “- - - -” flashes immedi-ately after the completion of the automatic calibration.Sensitivity is set and entered even when the sensitivity difference is insufficient. Be sure to confirm that the detection is properly performed.Selecting mode (Power/Timer)Power selectionFS-V1/FS-T SeriesSelect the sensitivity setting procedure according to the target condition. (FS-T has no display.)For sensitivity adjustment using a moving target •Fully automatic calibration1.Pass a target through the optical axis while pressing the SET button.2.Confirm that the calibration indicator (yellow LED) flashes.3.Release the SETbutton. The calibration indicator goes off.For target positioning •Positioning calibration1.With no target, press the SET button and release it. TheHigh Accuracy Fibreoptic SensorsFS-V+VBrownLock+VBrownLockNPNPNPABAB Optimal position[Note]When only a single unit is used, the mutual-interference prevention function cannot be used.Mutual Interference Prevention FunctionUp to four sensors can be con-nected without being affected by light beams from adjacent units.When several units are connected, the FS01 Series alternates the light emission timing with up to four sensors so that the adjacent sensors ’ light beams do When the TURBO mode is selected with the FS-M Series, up to 8 sensors enable stable detection without 2.With no target, turn the trimmer counter-clockwise until the green LED lights (turns off). – Point B3.Set the trimmer midway between points A and B. Confirm sensor operation.With a target in place, turn the trimmer counterclockwise until the green LED turns Point BSet the trimmer midway between points A and B. Confirm sensor operation.Precautions for adjustmentWhen the sensitivity difference is insufficient:After calibration is completed, the stable operationindicator (green LED) flashes if the sensitivity difference is insufficient. The FS-V1 LCD display flashes a row of External calibration functionSensitivity can be set using a signal input from anexternal device. The input time should be 20 ms or more.For external calibration, set the key-protection switch to LOCK.When several units are connected, only the units with the key-protection switch set to LOCK are externally cali-brated.•The FS-V , FS-T Series and FS-M Series can be used together.High Accuracy Fibreoptic Sensors33112Stable operationlevel Detection levelStability output“ 8 seconds ”The received light quantity does not exceed the stable operation level 31 times continuously .exceed the stable operation level 8 seconds continuously .900800Detecting distance X (mm)Detecting distance X (mm)Detecting distance X (mm)20040060080010001600140012000.11101001000xE x c e s s g a i n100020003000400050000.11101001000xE x c e s s g a i nSUPERTURBOSUPERTURBOFINESUPERTURBOFINEFS-V/T+FU-7F, 86+F-1FS-V/T+FU-7F, 86+F-2*Operating levelOperating level*Data was obtained using a 5-m type fiber unit.1001000xs g a i n1001000xs g a i nFS-V/T+FU-5FZ, 77FS-V/T+FU-75FWhen the received light quantity exceeds the detection level but does not exceed the stable operation level for 8 seconds continuously ”,the stability output is activated.Reset: When the stability output is activated, clean the front surface of the fibre unit or realign the optical axis so that the stable operation indicator (green LED) lights again. The stability output is reset when detection is done with the stable operation indicator (green LED) turned on.Operation chart[Note]When several units are connected, the stability outputs of all the units are output from the main unit based on OR logic.Self-diagnostic FunctionReceiver excess gain vs. detecting distance (Typical)FS-T1/V1 detecting distance is the same as that for FINE mode.High Accuracy Fibreoptic SensorsFS-V (SUPER)+FU-4F, 6F, 66, 85FS-V (SUPER)+FU-49X, 69XFS-V (SUPER)+FU-4F, 6F, 66, 85250300051015205101525XY510152025303545051015 5Y 40X D i s t a n c e Y (m m )D i s t a n c e Y (m m )Dia.Gold wire ø0.01Copper wireø0.1Copper wireø0.320Operating distance vs. detecting distance (Typical)Detecting area (Typical)High Accuracy Fibreoptic Sensors100101E x c e s s g a i nFS-M (TURBO)/ FU-4F, 6F, 66, 85Operating level100101E x c e s s g a i nFS-M (TURBO)/ FU-49X,69XOperating level XXWhite mat paperWhite mat paperFS-M (TURBO)/ FU-4F, 6F, 66, 854812FS-M (TURBO)/ FU-49X, 69XXYTarget: 30 x 30white mat paper 100200300400FS-M (TURBO)/ FU-7F, 86+F-2XYaxis (Typical)High Accuracy Fibreoptic SensorsFS01Hints on Correct Use221Using the cutterCut the free-cut fibre unit to the desired length using the included cutter.1.Insert the fibre unit into the corresponding cutter hole to the desired length.2.Cut the fibre by quickly pushing the blade all the way down.Stopping the blade midway will prevent a clean cut, thereby lessening the detectingTilt the quick-release lever. Insert the fibre unit until it stops, and then lift the quick-release lever.amplifier, and then lift the quick-release lever.High Accuracy Fibreoptic SensorsPower lines or high-voltage lines Mounting expansion unit1.Mount amplifiers to a DIN rail one at a time.2.Slide one expansion unit toward another. Align the front claws of the amplifiers and push the amplifiers together until they click.3.Fix the amplifiers together by pushing an end unit onto each end (The end units are included in the expansion unit. Be sure to use end units.).When extending, use the cablewhose sectional area is more. Do not extendIf the amplifier cable is placedtogether with power lines or high-voltage lines in the same conduit, detection error may occur due to noise interference, or the sensor may be damaged. Isolate theHigh Accuracy Fibreoptic SensorsFree-cut2000ø2.2( ) shows FU-5FZ.FU-32100015150.62.3ø0.82ø1.3stainless steelø0.6(Beam dia.)ø2.5 stainless steelUnit: mmHigh Accuracy Fibreoptic SensorsFS0178Unit: mm FU-77FU-77GFU-78FU-79FU-84CFU-86FU-88FU-92FU-96Diffuse-reflective typeFU-4F/4FZFU-6FFU-21XFU-21X+F-2HAHigh Accuracy Fibreoptic SensorsFS0179Unit: mm( ) shows FU-35FZ.( ) shows FU-35FZ.( ) shows FU-66Z.FU-22XFU-25FU-31FU-33FU-35FA/35FZFU-35FA(35FZ)+F-2HAFU-35FA(35FZ)+F-3HAFU-43FU-45XFU-48FU-49XFU-63TFU-63/63ZFU-65XFU-66/66ZFU-67FU-67GHigh Accuracy Fibreoptic SensorsFS0180®*Do not bend or cut this portion.Across-flats: 6.8, FU-68FU-69XFU-81CFU-82CFU-83CFU-85FU-87Definite-reflective typeFU-37FU-38FU-38RFU-38VLiquid-level typeFU-93FU-94CFU-95Unit: mmHigh Accuracy Fibreoptic Sensors30.736.53.822.825.625.481630.8(13)2 x ø3.4,12 min.3.9, 3-core (Brown/Blue/Black) x 0.34 mm2Cable length: 2 mDIN-rail mountingUnit: mmWhen the mounting bracket (supplied with FS-V11) is attached:High Accuracy Fibreoptic SensorsFS01822.the end unit (accessory to the FS-R0, T2, M2).When expanding an FS-R3, refer to theFS-R3 dimensional drawing.2DIN-rail mountingUnit: mmProtective tube (optional)OP-6630OP-6631Attachment (optional)F-1F-4F-4HAFS-R0FS-R3End unit (included in the FS-R0,T2,M2)When several units are connected:MEMO83。

基恩士FS-V11中文说明书PPT精选文档

基恩士FS-V11中文说明书PPT精选文档
例:当前光量为500,设定值也是500,那么比例值 就会显示100%;
当前光量为500,设定值是1000,那么比例值 就会显示50%;
当前光量为1000,设定值是500,那么比例值 就会显示200%
3
每快速按一次模式选择键,就会 在上面的4种状态下切换一次。
同时按住手动键的上键和MODE键,或同时按 住手动键的下键和MODE键 3秒以上,当显示 Loc时,即锁定完成。 重复上述步骤,当显示unL时,即解除锁定完成。
光源强度和计时器的模式选择
按住MODE键 3秒以上,即进入到光源强度和延迟时 间的模式选择中,先默认进入到光源强度选择模式, 用上下键选择光源模式,有FINE,TURBO和SUPER 这3种模式,FINE是在短的检测距离中检测微小差异 时使用,TURBO是在FINE模式的检测距离不足时使 用,SUPER是在环境严苛如有灰尘时使用。 再快速按MODE键一次,即进入到延迟时间的模式选 择中,有OFF,10ms和40ms 这3种模式。 再快速按MODE键一次,就回到了受光量的当前2显示。
按钮功能 1
显示数据 汉威控苏制工州程工系业统园有区限公司锁定动作
受光量显示值,显示当前检测到 的光量数值,会随着光纤感受到 的光的强度的变化而变化,最大 值为4095,最小值为0。
1234
123P
-HLD
-HLD
1234
123P
额定增益显示,即光量的比例值的显示, 例如:测定值=设定值时,显示100%;测 定值×2=设定值时,显示50%;测定值=设 定值×2时,显示200%,也就是进行一个 换算,测定值相当于设定值的百分之几, 比例值能够反映出来Light on或Dark on动 作的信号是否稳定。
按 SET键

放大器操作说明

放大器操作说明

放大器操作说明一、放大器的设置1.打开Nexus 元件的电源并使Nexus 元件初始化。

2.如果Nexus 元件没有显示主菜单,则应按底下的“Home ”键,直到出现主菜单。

在主菜单上应有诸如“Amplifier Set -up (放大器设置)”,“Transducer Set -up (传感器设置)”等选项。

如照片1所示:3.滚动到“Amplifier Set -up (放大器设置)”并按底下的“↙”一次。

如照片2所示:照片 1照片 24.在“Amplifier Set -up (放大器设置)”菜单下,应通过在底下箭头键来滚动到“Hz ”,以确保“Hz ”显示加亮。

一旦“Hz ”显示加亮,则按 “Ch ↓”键。

随后应用“+”和“-”按键来设置Hz (频率)为A 。

一旦通道1设置为A ,则应按 “Ch ↓”键,并对通道2,3和4作同样的工作。

如果是2通道Nexus 元件,那么只需要编程两个通道。

当所有通道设置为A 时,按“Home ”键返回。

如照片3所示:然后,用“→”键移动到“Out (输出)”。

一旦“Out (输出)”被显示加亮,使用“Ch ↓”键和“+”与“-”键把每个通道都设置为316mV/Pa 。

当所有通道都设置为316mV/Pa 后,按“Home ”键返回。

最后回顾一下菜单,确保所有的通道都被分别设置在A 下,“Out ”输出为316 mV/Pa 。

当所有设置项都设置正确后,按“Home ”键返回。

如照片4所示:照片 3滚动到“Transducer Set -up (传感器设置)”下并按底下的“↙”一次。

如照片5所示:(此步可以省略,因为麦克风的灵敏度是自动识别的不用设置)编辑此菜单需要声学传感器的校准数值。

当得到校准数值后,滚动到“Sensitivity (灵敏度)”并按“Ch ↓”键。

如照片6所示:照片 4照片 5随后将处在显示加亮的十进制数值的通道#1。

用“+”与“-”键把此数值设置为对应于此通道/声学传感器的校准/灵敏度数值。

S-FS-N 系列sensor放大器的使用

S-FS-N 系列sensor放大器的使用
2.1 接线图
2.1.1 针对电缆类型接线图
1路输出型(仅FS-N11N/N11P) 2路输出型(仅FS-N13N/N13P)
监视器输出型(仅FS-N11MN)
连结至输入 阻抗大于 10K的设备
8
2.1.2 针对M8/e-CON连接器类型接线图
9
10
2.2 连接光纤模块
Ⅰ 若光纤是自由切割类型,请切 掉多余的部分 ①将光纤插入切断器孔中。 ②快速按下刀片,一次切断光纤。
25
菜单功能表与推荐光纤模块
26
3.6 初始化
传感器放大器可以重设为出厂默认设定。
Ⅰ同时按住SET和PRESET按钮保持3秒或 更长时间。 “rSt”显示并闪烁。 Ⅱ 按MODE按钮。 Ⅲ 按下手动按钮以显示“init”。 Ⅳ 按MODE按钮。 初始化设置后,画面显示“Ok”,随后 会替换为当前接收到的光强度。
设定值 为“50.0”
当前值设 为“100.0”
14
3.2.2 工作预设定功能
此功能会将当前值校正为“0”。在使用参数执“100” 执行预设定功能后,再使用“0”参数执行此功能,可将2 个随机设定点校准为“100.0”与“0”。 ◆启用工作预设定功能 启用预设定功能时,同时按下 PRESET和手动按钮(右)。 该点的接收光强度设为“0” 而利 用预设定功能为“100.0” ,值不会 变化。 ◆禁用工作预设定功能 PST 指示灯亮起时,请按住 PRESET按钮。 ● PST 指示灯熄灭时,表示工 作预设定功能已禁止。 当前 值为 “0”
17
3.2.5 两点校准
两点校准是灵敏度设定的最基本方法。只需在产品存在和不存在时 分别按SET按钮一次,即可建立设定值。 此时无 Ⅰ 产品不存在时按SET按钮一次。 产品 Ⅱ 产品存在时按SET按钮一次。 设定值即时闪烁后表示校准完成, 然后停止(灯亮)。 按手动按钮调整设定值。

FS-M1-c光纤驱动器说明书

FS-M1-c光纤驱动器说明书
• 使用市售的轉換調節器時,將機架接地端子與接地端子接 地。
• 勿將 FS-M 系列使用於戶外,或外來光線可以直接進入光 接收表面的地方。
• 在最大感度設定時,檢測距離可能由於個別模組的特性差 異而有所不同。
• 若接線不正確,模組可能會發熱,或靈敏度設定可能會變 動。
• 未使用穩定度輸出時,從根部切斷橙色纜線,或是把這條 纜線連接到電源的 0 V((PNP 模式的陽極)端。*
3. 簡易的接線 • 擴充模組不需電源纜線。 • 一個主要模組最多可以連接 16 個
擴充模組。
警告
• FS-M1(P)/M2(P)係供目標檢測之用。勿將產品使用於保護人體的 安全電路中。
• FS-M1(P)/M2(P)不防爆。不要在有易燃氣體、液體或粉末的環境 中使用產品。
• FS-T0 無控制輸出纜 線。
TURBO 模式: • 於 FINE 模式所提供的檢測距離不足時使用。
供長距離檢測,或檢測低反射率的目標之用 • 反應時間:500μs
在切換 FINE /TURBO 模式後,請務必重新調整靈敏度。
使用 FU-12 時,關於靈敏度調整程序請洽 KEYENCE。
● 自我診斷功能
受光量“連續 31 次”或“連續 8 秒”超過檢測準位但未超過穩定動作準 位時,就會啟動穩定度輸出。
5. 把靈敏度設定在 A 點與 B 點的中間點。
6. 在靈敏度調整後,視有目標時要開啟或關閉感測器而選擇 L.ON 或 D.ON 模式。
• 靈敏度差異小於指示燈上的一格時,依據靈 敏度微調整器的位置調整靈敏度。若 A 點與 B 點間至少有半圈的差異,就可以進行穩定 的檢測。
選擇 FINE /TURBO 模式 FINE 模式: • 供檢測微小差異或高精度定位之用 • 反應時間:250μs

基恩士FSNN放大器常用调试说明书课件

基恩士FSNN放大器常用调试说明书课件

易于集成
具有小型化、模块化的设计, 方便与其他电路或系统集成。
高可靠性
采用高品质的元器件和严格的 生产工艺,确保产品在各种恶
劣环境下仍能稳定工作。
应用领域
01
02
03
通信领域
用于信号传输、放大,保 障通信质量和稳定性。
工业控制
用于传感器信号的放大和 处理,提高工业控制系统 的精度和稳定性。
科研实验
在进行软件更新之前,请 务必备份当前版本的数据 和配置。
在软件更新完成后,重新 启动基恩士fsnn放大器, 确保更新生效。
故障排除
如果基恩士fsnn放大器出现故 障,首先检查设备外观和连接 线缆,排除物理损坏的可能性。
如果故障仍然存在,请尝试重 启设备,看是否能够解决问题。
如果重启无效,请联系基恩士 技术支持获取帮助,提供详细 的故障描述和设备信息。
设备发热
01
总结词
设备发热是指基恩士fsnn放大器在工作时,由于功耗和内部元件的发热
效应,导致设备温度升高。
02
详细描述
设备发热可能会影响放大器的性能和稳定性,严重时甚至可能损坏元件。
03
解决方案
合理规划和使用散热装置,如散热片、风扇等,以降低设备温度。同时,
还可以优化电路设计,降低功耗和发热量。在高温环境下使用时,应采
连接电源
将电源适配器连接到放大器,确 保电源正常供电。
连接电脑
使用USB线或网线将电脑与放大器 连接,确保数据传输稳定可靠。
启动调试软件
打开调试软件,并进行必要的配置 和设置,以便进行后续的调试工作。
03
调试步骤
开机自 检
总结词
确认设备正常启动

KEYENCE 光纤传感器放大器 FS-V21 V11 V1 系列说明书

KEYENCE 光纤传感器放大器 FS-V21 V11 V1 系列说明书

LineupFeaturesD ual digital display/Bar LED/Two-colour display S tandard single output/Dual output/Analogue outputE xpansion connection reduces wiringExpert Engineering SitesAn on-line guide of automation knowledge and techniques1-Line System FibreSensor Amplifi ers FS-V21/V11/V1Refer to P.837 for a list of productscomplying with EU Directives.Refer to P.853 for UL Certifi ed Products.Dedicated parallel operation chip (FALCON)Since 1996, the FS-V Series has utilised a parallel processing chip rather than a general-purpose CPU. This chip is designed especially for fi breoptic sensors in order to offer accelerated data processing and specialisation. This chip is what gives KEYENCE fi breoptic sensors their stunning performance.Dual digital display indicates current value (received light intensity) + setting valueFS-V20 SeriesCurrent value (received light intensity) + sensitivity margin displayFS-V10 SeriesDual output as standard.Monitor intensity of received light for PS Series unitsFS-V1SeriesBar LED monitorOperation indicatorDigital monitorManual button Output selection switchMode buttonSet buttonOperation indicator*Dual digital monitorMode buttonOutput selection buttonSet buttonManual button* The operation indicator on the FS-V21X (infrared type) does not light up.Sensitivity margin can be checked on the bar LED in 5% increments.It is possible to check the received light intensity of a PS-T2 unit or aPS Series expansion unit by simply connecting to the FS-V1.Operation indicatorOutput timer selection switchLCD display monitorUp/down keysSet buttonMode buttonOutput selection switchTuning display indicatorFS-V20 SeriesFS-V10 Series,FS-V1All series listed above require less wiring when using main and expansion units. for details on wiring.Main units include mounting brackets and expansion units include end units.Mounting bracketOP-25431End UnitsOP-26751(x2)* FS-V1(P) is supplied with a different mounting bracket.Amplifier (FS-V20 Series)1. Use the FS-V21RM in the FINE or TURBO mode when outputting signals with a monitor.2. I f more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.1 or2 Units: -10 to 55°C,3 to 10 Units: -10 to 50°C, 11 to 16 Units: -10 to 45°C3. The operation indication light of the infrared types does not illuminate.4. 20 mA at maximum for the expansion unit.Amplifier (FS-V10 Series)1. I f more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.3 to 10 Units: -10 to 50°C, 11 to 16 Units: -10 to 45°C2. The response speed varies depending on the number of expansion units connected.3. The FS-V1 is equipped with two outputs. The FS-V10 has no control output.4. Neither the FS-V12 nor the FS-V10 can be used as a standalone unit.DimensionsUnit: mmAmplifierFS-V21(R) Series (Main unit)FS-V22(R)/V20R Series (Expansion unit)FS-V10/V12/V12PWhen the mounting bracket (Optional)FS-V21(R)(Main unit) is attached:FS-V21R/21G/21X (Main unit)FS-V21RP (Main unit)FS-V11/V12FS-V11P/V12PFS-V21RMFS-V22R/22G/22X (Expansion unit)FS-V22RP(Expansion unit)5 to 40 VDC12 to 24 VDC0 V0 V*FS-V21RM only.Ω or higherø3.9, 3-core x Brown/Blue/Black: 0.34 mm* FS-V21RM : ø3.9, 4-core xBrown/Blue: 0.34 mm Black/Orange: 0.18 mm922 ** The FS-V20Rdoes not have connecting cables.2 *Accessory: End unit Caution label x 2x 1* T he FS-V10 does not have connecting cables.*F S-V11 only0 V*FS-V11P onlyFS-V1FS-V1P(External calibration input circuit)FS-V11/V11PFS-V1/V1Pø3.9, 3-core x Brown/Blue/Black: 0.34 mm 2Accessory: Mounting bracket x 1When the mounting bracket (Optional)FS-V11 is attached:When the mounting bracket (Optional)FS-V1(P)is attached:ø3.9, 5-core x Brown/Blue: 0.34 mm 22Accessory: Mounting bracket x 1Rear of mounting bracketEnd unit (Optional)OP-26751DIN-rail mounting*When several units are connected* The above is for the FS-T2 and M2.。

欧姆龙光纤放大器说明书【新版】

欧姆龙光纤放大器说明书【新版】

光纤放大器使用提示:故障解决:光纤放大器,面板显示和实际输出是同步的,如果面板显示正常,则说明光放大器输出正常,如果这种情况下测试光放大器时光功率下降或不够,最大的可能性有以下几种:1.光功率计不准,国产的光功率计只能测试光功率输出较小的设备,不能测试大功率输出的EDFA,测试光放大器的光功率计必须原装进口,不能把不准确的仪器当作标准来使用。

2.输出口的法兰损坏,这个可能性较小。

3.用户使用不当,在机器工作时插拔,烧伤光放大器输出的尾纤头,造成光放大器输出功率下降,如发生这种情况,只要重新熔接光放大器的输出接头即可。

4.用户使用的尾纤质量太差,纤芯过长,在插入尾纤后擦伤光放大器的输出接头,这个现象是第一次测试是好的,第二次插入再次测试时就光功率下降了,解决这个问题也只要重新熔接光放大器的输出接头就可,5.光源的波长不对,如果1550nm光发射机的波长有偏差,会造成光放大器的输出光功率不够,也会造成面板显示偏小。

6.输入光放大器的光功率较小,如果低于标准值时可能会造成光功率变小,同时面板显示也会变小。

注意事项1.切勿将光纤输出口指向人体,尤其是眼睛,以免造成损伤。

2.切勿在通电状态下进行路由的连接,以免因操作不当造成输出尾纤端面烧伤。

3.由于产品的输出功率较大,使用时请关注本机的工作室温,保持通风良好。

欧姆龙光纤放大器调试方法制作光纤时,采用特殊工艺,在光纤芯层沉积中掺入极小浓度的稀土元素,如铒、镨或铷等离子,可制作出相应的掺铒、掺镨或掺铷光纤。

光纤中掺杂离子在受到泵浦光激励后跃迁到亚稳定的高激发态,在信号光诱导下,产生受激辐射,形成对信号光的相干放大。

这种OFA实质上是一种特殊的激光器,它的工作腔是一段掺稀土粒子光纤,泵浦光源一般采用半导体激光器。

当前光纤通信系统工作在两个低损耗窗口:1.55μm波段和1.31μm波段。

选择不同的掺杂元素,可使放大器工作在不同窗口。

(1)掺铒光纤放大器(EDFA)掺铒光纤放大器由一段掺铒光纤和泵浦光源组成,如图1所示。

基恩士放大器 FS-N系列详细说明书-中文

基恩士放大器 FS-N系列详细说明书-中文

基恩士放大器 FS-N系列详细说明书-中文------------------------------------------------------------------------------------------------基恩士放大器 FS-N系列详细说明书-中文数字光纤传感器FS-N10 系列用户手册使用前请阅读本手册。

本手册应妥善保管,以便日后参考。

介绍本手册介绍 FS-N10 系列的基本操作和硬件功能。

请仔细阅读本手册,以确保安全实现 FS-N10 系列的性能和功能。

请将本手册保存在安全的地方,以便将来参考。

请确保本产品的最终用户收到本手册。

?符号以下符号提醒您注意有关防止人身伤害和产品损坏的事项。

注提供关于正确操作的附加说明。

提供操作的高级信息和有用信息。

安全预防措施正确使用须知?请勿沿电源线或高压线一道布设放大器线路,否则可能因噪声导致传感器发生故障或受损。

?使用市面所售的开关稳压器时,请将壳体接地端子和接地端子接地。

?请勿在户外或光接收元件受外部光线直射的场所使用 FS 系列产品。

——————————————————————————————————————------------------------------------------------------------------------------------------------?因特性的个别差异以及光纤模块型号的不同,所有模块的最大感测距离或显示值可能不尽相同。

?如果在启用 APC 功能的情况下长时间使用传感器,LED 指示灯将承载沉重负荷。

在这种情况下,传感器因发光所需耗电量是恒定的,并将显示"END APC"。

传感器仍可继续使用。

不过,如果要关注接收光量的微小变化,请更换传感器。

??关于 UL 认证FS-N 系列已通过 UL 和 C-UL 认证,符合 UL 与 CSA 标准。

?适用标准UL508 工业控制设备CAN/CSA C22.2 No.14-M05 工业控制设备?UL 档案编号 E301717?UL 类别: NRKH, NRKH7?外壳类型 1(基于 UL50 标准)??UL 认证相关说明?FS-N 系列所用电源必须通过针对 2 级输出(据美国国家电气法规 (NEC) NFPA70之规定)的 UL 列名认证。

无线信号放大器使用说明书

无线信号放大器使用说明书
易造成无线信号互相干扰,尽量远离干扰源。 易受无线信号屏蔽器影响 由于无线的特殊性,天线周边尽量避免物体的直接阻挡,需保持周边空旷,才能
达到最佳的接收效果。 要注意避雷。 用户自行加装天线要注意放大器与天线之间的线缆长度不要超过 50cm。
疑问解答 一
■ 通讯两端的天线放得已经很近了,可传输速率却反而上不去? 这是因为放大器的发射功率比较强,距离太近使你的接收设备(网卡/路由)信
号饱和造成失真。通讯两端的距离保持在50cm 以上则不会有此问题。 ■ 放大器应该安装在无线路由器上还是无线网卡上?
都可以安装,安装在无线路由器上可使所有与之建立连接的无线用户的信号得 到加强;安装在无线网卡上只能使该网卡的信号得到增强。 ■ 为何加了放大器仍然收索不到?
对方网络安装一个放大器可以使空旷覆盖距离增加 1~2 倍。若希望建立无线链 接的两个终端距离太远,此时建议用户在两个终端都安装放大器和并加装高增益定 向天线。 ■ 放大器的发射功率是不是越大越好?
路由器上的天线。 Step2:拿出SMA连 接线,连接无线路由 器与信号放大器(TO Radio)。 Step3:在信号放大 器的另一端(TO Antenna)接上天线。
设备安装图示 四
放大器和无线路由器,高增 益天线连接图示
设备安装步骤: Step1:先拆除无线路由器
上的天线。 Step2:拿出SMA连接线, 无线路由器与信号放大器 (TO Radio)。 Step3:在信号放大器的另 一端(TO Antenna)接上高 增益天线。
放大器外观
展示几款2.4GHZ双向无 线信号放大器,身高不足 10CM,如右图所示:
相关概念
何谓2.4GHZ无线技术? 2.4GHz无线技术,是一种短距离无线传输技术,具有带宽高( 2Mbps),双向传 输,抗干扰性强,传输距离远(短距离无线技术范围),耗电少的优点,用于无 线键鼠等室内场合。

FS-N10_中文说明书 11-08

FS-N10_中文说明书 11-08
数字光纤传感器
FS-N10系列
使用手册
96M00603
危险 警告 小心
不遵照相关说明操作可能导致人员死亡或受严重伤害。 不遵照相关说明操作可能导致人员受伤。 不遵照相关说明操作可能导致产品损坏(产品故障等等)。
注意 提供关于正确操作的附加说明。
提示
提供关于所述功能的有用提示。
请参阅《FS-N10 系列用户手册》了解关于 FS-N10 系列功能的更多信息以及有关配置的详细说 明。
向箭头 1 方向往前推机身的同时,朝箭头 2 方向按下去。
2 若要取下传感器,向箭头 1 方向往前推机身的同时朝箭

头 3 方向抬高。
贴墙安装(仅限主模块)
1 将模块装入选配的安装架 (OP-73880),如图 2 所示,用两个
M3 螺丝加以固定。
1 图 1
警告
• 本产品供目标物检测之用。为保障人身安全,请勿将本产品用于安 全电路。
1 拆下主模块和子模块的防护罩。
2 将放大器逐个安装到 DIN 导轨。
3 将主模块和子模块滑动到一起。将子模块的两个卡槽与
主模块侧面的凹槽啮合,直到听到 / 觉察到“咔嗒”一声 响。
4 将终端模块(选配件:OP-26751)安装到 DIN 导轨,方法
同步骤 (2)。
5 使终端模块从两侧夹紧放大器。用十字螺丝刀拧紧顶部
其它校准方式
增强在多尘等恶劣环境下的适用性
z 最大灵敏度设置
在下图所示情形下,按住[SET(] 设置)按钮保持3秒或更长时间。当“5'6”(设置)闪烁时松开按
钮。 设置的灵敏度较接收到的光强度略高。 对照型 : 有工件
工件
按住保持 3 秒或更长时间
反射型 : 无工件

fsv33光纤放大器说明书

fsv33光纤放大器说明书

fs-v33光纤放大器说明书FS-V33光纤放大器是一款高性能的光纤放大器,适用于光纤通信、光纤传感、科研实验等领域。

本说明书将详细介绍FS-V33光纤放大器的技术参数、使用方法以及注意事项,方便用户合理、安全地使用该产品。

一、技术参数1.功率放大范围:0 dBm - 20 dBm2.增益调节范围:0 dB - 20 dB3.频率响应范围:10 Hz - 2 MHz4.输入/输出阻抗:50 Ω5.噪声系数:≤ 4 dB6.输入/输出端口:光纤接口(SC/APC)7.工作温度范围:-10 ℃ - 60 ℃8.电源电压:AC 100-240V,50/60Hz二、使用方法1.接通电源:将电源插头插入FS-V33光纤放大器的电源插座,然后将电源线插入电源插座,确保电源线安全可靠地连接。

接通电源后,FS-V33光纤放大器即可开始工作。

2.光纤连接:使用光纤连接器将待放大的光源与FS-V33光纤放大器的输入端口(SC/APC)连接。

确保光纤连接牢固,避免光纤松动导致信号损失。

3.增益调节:通过FS-V33光纤放大器的增益调节旋钮,可以调节输出信号的增益。

以适应不同的应用场景和要求。

根据实际需要将增益调节旋钮顺时针或逆时针旋转,实现增益的增大或减小。

4.散热注意:由于FS-V33光纤放大器在工作过程中会产生一定热量,为了保证其正常工作和寿命,使用时应确保其周围空间通风良好,避免堵塞散热口。

三、注意事项1.请勿将FS-V33光纤放大器暴露于有害气体、腐蚀性颗粒或高温环境中,以免损坏设备或影响使用寿命。

2.在使用FS-V33光纤放大器时,请勿轻易拆卸或更换器件,以免对设备性能产生负面影响或引发其他问题。

3.如果长时间不使用FS-V33光纤放大器,请拔掉电源插头,以免设备发生故障或损坏。

4.使用过程中,严禁在FS-V33光纤放大器上涂抹任何化学物质或液体,以免对设备造成损害。

5.如发现FS-V33光纤放大器存在烟雾、异味、异响等异常情况,请立即停用并联系售后服务中心。

keyence 高精度光纤传感器 FS01系列 说明书

keyence 高精度光纤传感器 FS01系列 说明书

详细信息及资料,请浏览/askg88数字 LED条形 LED手动校准键模式选择键特性●同行业中第一个双监视系统●自动和手动校准●20 位并行处理芯片●高精度,大功率●节省导线的免线或单线连接系统检测距离透过式 —— 最长 3600 mm ,带镜头扩散反射式 —— 最长 300 mm限定反射式 —— 最长 14 mm自动设置键高精度光纤传感器行微调。

操作者可以用自动设置键进行快速校准后开始检测,然后用手动调整键对灵敏度进行微调。

只使用自动校准或者只使用手动校准都能够获得稳定的检测。

即使没有经验的操作者也能够进行精确调整。

新型 20 位并行处理芯片 + 12 FS-V10 系列拥有一个新研制的芯片。

这个芯片可以同时处理括 “高速校准接受光强度”,“及“最高/最低值保存显示”理 CPU 相比,这个芯片有许多优点,如低电流消耗、高速反应以及热值降低,从而提高了总体可用性。

89光电传感器接近传感器压力传感器PLC计数器计时器条码读取器影像系统位移传感器光透过型测量仪器模拟信号 控制器数位显微镜静电消除系统高精度传感器区域传感器FS01FS01 系列放大器功能表2. 最多 4 个5. 按键8. 二个模式:精细 / 涡轮3. 精细模式:最多 4 个,涡轮:最多 8 个6. 微调电容器光电传感器接近传感器压力传感器PLC计数器计时器条码读取器影像系统位移传感器光透过型测量仪器模拟信号 控制器数位显微镜静电消除系统高精度传感器区域传感器90FS01型号: FU-66数字 LED 监视被遮挡的光线数字 LED 监视器从 0 到 4095 以递增方式显示光接收元件处的光量。

这样可以使操作者确定传感器上粉尘积聚的程度以及光轴的偏移。

此外,检查数字读数表示的光量变化,可以确保最佳设定值,提高检测的可靠性。

苛刻环境中检测超高精度检测小目标物接收的光量:多大目标物接收的光量:少91光电传感器接近传感器压力传感器PLC计数器计时器条码读取器影像系统位移传感器光透过型测量仪器模拟信号 控制器数位显微镜静电消除系统高精度传感器区域传感器FS01自动避免干扰在涡轮 / 特种涡轮方式下,最多可以并列安装 8 个光纤而不会有相互干扰。

光钎放大器说明书

光钎放大器说明书
显示选择
出厂默认值仅为“1”。 只有在显示定制选择中选定后( 第5 页第8 项),方可显示
其它项目。
*1 选择ULTRA/MEGA 模式时,可以以五位数显示当前接收的光强。
按一次按钮时,设置值会闪烁。
闪烁时,按按钮可以修改设置值。
*2 超出的增益在85% 至115% 的范围内以5% 的增量显示。
化。 配置灵敏度设置值的方法与一般检测模式相同。
设置显示比例
此功能用于根据“目标值比例”调节接收光强。
1 选择显示值校正功能时( 第5 页第6 项),首先选择显示比例功能,然后设置目标
值。 ( 这里说明的是目标值设置为2000 的情况。)
2 正常显示过程中,同时按MODE( 模式) 和SET( 设置) 按钮。
请记录下PIN 号码,以防遗忘。
如果没有使用正确的PIN 号码,键盘锁将无法停用。
正确使用的提示
? 请勿沿着电源线或高压线对放大器进行配线,否则传感器会因噪声发生故障或
受损。
? 使用商用开关式稳压器时,确保将机框接地端子和接地端子接地。
? 请勿在室外或者外部光线能够直接进入光接收表面的位置使用FS 系列。
须更换传感器。
解除键盘锁的步骤与此相同。
有关键盘锁定水平和PIN 号码键盘锁功能的更多信息,请参考第6 页。
操作配置
一般情况下,该模块可以在基本设置下使用。
也可以根据需要设置其它功能。
按 至少3 秒钟显示基本菜单。
使用按钮选择功能,并按 确定。
选择END,并按时确认每个项目的设置值。
基本
设置菜单
( 这时,对当前光强执行按比例缩放。)
根据目前接收到的光强,在如下范围设置基准光接收强度:
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Hold the displayed value.
Mode Selection <Using M , and >
Current value M
Power selection M
Timer selection
M
M
M
• Directions (x 1) [FS-V12(P) only]
PART NAMES AND FUNCTIONS
Button Names
MODE selection button M <Display switching>
SET
MODE
D.ON
L.ON
AUTO SET button S MANUAL buttons <Sensitivity setting>
Display Switching <Using button M >
SET
Auto SET SET button
SET
Manual button
MODE
D. ON L. ON
MODE MODE button
Output selector switch
DARK-ON LIGHT-ON
Expansion connector
Expansion connector
Single-core cable
For sensitivity adjustment using a moving target
Model
NPN output
FS-V11
FS-V12
FS-V10
PNP output
FS-V11P
FS-V12P

Light source Response time
Red LED
250 µs (FINE)/500 µs (TURBO)/ 1 ms (SUPER)
410 µs to 1.7 ms 1.
3. When several units are connected, the allowable ambient temperature changes depending
on the following conditions. To connect several units, be sure to mount them to a DIN rail (metal DIN rail). Make sure that the output current is 20 mA. max. • When 3 to 10 units are connected: -10 to +50 °C • When 11 to 16 units are connected: -10 to +45 °C
Timer function Control output
OFF-delay: 40 ms, 10 ms Timer OFF (switch selectable)
NPN or PNP open-collector 100 mA max. (40 V max.), Residual voltage: 1 V max.
SELECTING DISPLAYED DATA
The display changes every time the MODE button is pressed.
s Displaying received light intensity
Received light intensity
Press this MODE button once.
Protection circuit
Reverse polarity protection, Over-current protection, Surge absorber
Power supply voltage Current consumption
12 to 24 VDC ±10%, Ripple (P-P) 10% max. 50 mA max.
Output selector switch LIGHT-ON
Display
Hold value Peak-hold value
Note: To change the setting value, press
or
while the setting
DARK-ON
value is flashing.
1
Bottom-hold value
FINE
SET
monitor
40ms
FINE SET 40ms
FINE SET 40ms
10ms
10ms
10ms
OFF
OFF
OFF
Calibration indicator
Digital LED monitor
SET
MODE
D. ON L. ON
D. ON L. ON
3-core cable
MODE
Setting Value Display/Change <Using >
Setting value
Received light
Sensitivity
intensity display
UP DOWN
Wait for 2 seconds
Hold the displayed value.
Excess gain display (%)
Weight (including 2-m cable)
Approx. 80 g
Approx. 45 g
Approx. 20 g
1. The response time varies depending on the number of expansion units connected.
2. The orange LED is normally part of the bar graph LED monitor. It is used as a calibration indicator during the setting of the sensitivity.
• Mounting bracket [FS-V11(P) onl]
• End unit (x 2) [FS-V12(P) only]
• Quick reference (x 1) [FS-V11(P) only]
FS-V10 Quick Reference Press the button for just a moment. Press the button for 3 seconds or more.
Operation mode
LIGHT-ON/DARK-ON (switch-selectable)
Indicators
Output indicator: Red LED Digital LED monitor: Red LED Bar graph LED monitor: Green/Orange LED 2. Calibration indicator: Orange LED 2.
10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions for two hours
500 m/s2 in X, Y and Z directions, three times each
Housing material
Body/Cover: Polycarbonate
Ambient illumination
Candescent lamp: 10,000 lx max., Sunlight: 20,000 lx max
Ambient temperature Relative humidity
-10 to +55°C 3. 35 to 85%
Vibration Shock immunity
009-077
Hybrid Fiberoptic Sensors
FS-V11(P)/12(P)/10
Instruction Manual
SAFETY PRECAUTIONSW NhomakorabeaRNING
• The FS-V11(P)/12(P)/10 are intended for target detection. Do not use the product in a safety circuit for protecting the human body.
Displaying the setting value