带电体的防护
7.4 The opening illustrated in Figure 7.4, is acceptable if, within the enclosure, there is no uninsulated live part or film-coated wire: a) Less than X distance from the perimeter of the opening; and b) Within the volume generated by projecting the perimeter distance X normal to its plane. X equals five times the diameter of the largest diameter rod that can be inserted through the opening, but not less than 4 inches (101 mm). In evaluating an opening, any barrier located within the volume usually is ignored unless it intersects the boundaries of the volume in a continuous, closed line.
1.切割件且 2.任何切割件的金属护罩 b.可能被握持的表面: 1.与带电体双重绝缘隔离或 2.不包封电气组件,并且与包含电气组件的所有不带电金属件隔离,其中电气组件用满
足81.1和81.1的第二条绝缘包封。
带电体的防护
7.2 An opening in the handle portion – the area likely to be handled during normal operation in guiding – of a lawn mower is acceptableBaidu Nhomakorabeaif the probe of Figure 7.1, when inserted as far as possible into the
1) The cutting member; and 2) Any metallic guard for the cutting member; and b) Surfaces likely to be grasped: 1) Are double-insulated from live parts; or 2) Do not enclose electrical components and are separated from all dead metal parts that enclose
7.2带电部分应固定或包封好以减少与非绝缘带电体的接触,绝缘刷无须额外的护罩。 7.2 手柄的开口部分-操作时可触及的部分是可以接受的,如果图7.1中的管子尽可能插入开口: 进入开口的距离不超过3.2mm并且 不能接触非绝缘带电体或漆包线。 7.3 根据7.1所述的要求和7.2中暗示的要求外,在以下情况下也能使用: 当使用不适当的力以不定的方向把7.2中管子插入开口时不能触及非绝缘带电部分或漆包线。 当使用不适当的力以不定的方向把7.3中管子插入开口时不能触及非绝缘带电部分或漆包线。
electrical components by insulation complying with the requirements in 80.1, and the second entry in Table 80.1.
操作时接触到的手柄或其他外表面可以导体如果满足以下要求: a.在可能被握持的表面和下列元件之间为满足80.1和80.1的第二条的要求的绝缘:
美洲割草机标准
手柄
6.4.3 The outer surfaces of a handle or other area likely to be grasped during normal operation may be of electrically conductive material if:
a) Insulation complying with the requirements in 80.1, and the second entry in Table 80.1, is interposed between the surfaces likely to be grasped and:
coated wire when inserted through the opening in any possible direction using no appreciable force; and b) A probe as illustrated in Figure 7.3, cannot be made to touch any uninsulated live part when inserted through the opening in any possible direction using no appreciable force.
opening: a) Does not enter the opening for a distance of more than 1/8 inch (3.2 mm); and b) Does not touch any uninsulated live part or film-coated wire. 7.3 With reference to the requirement in 7.1, and except as indicated in 7.2, an opening is capable of being used when: a) A probe as illustrated in Figure 7.2, cannot be made to touch any uninsulated live part or any film-