Computer equipment is the core part of the whole data center, and its development process decides that of data center; future application demands also guide the development direction of data center.
The adoption of modularized framework also means that there is no need in designing too big physical infrastructures at the prophase. On the contrary, users only need to deploy a data center as they need and make corresponding adjustments as their business needs expand.
Monitoring system module High reliability: equipment running and environment monitoring High adaptability: unified management inside and outside modules
Refrigeration system module High reliability: air supply between racks, high efficiency High adaptability: adapting to different pipelines similarly hereinafter
Integrated solution for Inspur data center
May 2015
Contents
I
Data center system composition
II
Micromodule data center
III
Application values of micromodule data center
Air distribution
Fire control
Power supply and
distribution
Smart integrated management platform
End Refrigeration
Lighting
Wiring
Product-based data center infrastructure
IV
Inspur data center products
V
One-stop solution for Inspur data center
VI
Inspur's data center performance
I. Data center system composition
Computer equipment
Total solution for computer room project
New fan system New fan system
UPS system
Leakage inspection system
Comprehensive wiring system
Glass broken alarm system
Automatically alarm
Power
distribution
UPS
system
Lighting
Power distribution
cabinet Lightning protection grounding
I. Data center system composition
Requirements for data center machine room construction include hierarchical and performance requirements, as well as technical requirements for machine room siting and equipment arrangement, environment, building and structure, air adjustment, electrical technology, electromagnetic screening, machine room wiring, machine room monitoring and security protection, water supply and drainage, and fire control.
I. Data center system composition
Comprehensive wiring
Ceiling
Raised floor
Wall Partit ion
Decoration project
Doors and windows
Video monitoring
Security access control
Accurate airconditioning system
Power distribution cabinet system
Fire alarm system
Access control system
Air-conditioning system
Video CCTV system
Fire extinguishing system
III. Application values of micromodule data center
Fast deployment and easy to use—the implementation period is reduced from months to weeks
Take customer demands as the design reference and high reliability, high availability, easy maintenance, expansibility as the principles in overall framework. Take standardization and modularization in the constructional design and realize factory premanufacturing and rapid assembly deployment.
Windows and doors system
Illuminating System fireproof glass partition
Infrared security system Flooring system
Power supply and distribution
systent hit Joint debugging Acceptance
the shelves
check
MDC Implementation
Antistatic flooring and simple lighting
Strong and weak current to each
module
Since the applications in the Micromodule Data Center are flexible and extensible, thus we can guarantee that the infrastructures in the data center are planned with needs and further realize highest efficiency and lowest cost in the whole life cycle of the data center;
Inspur MDC Smart Integrated Management platform
• Dynamic environment monitoring/prewarning • Monitoring server running status • Coordinated response to power supply • Air-conditioner /Server coordinated regulation • PUE real-time /interval computing • Reliable authority control
Power distribution system
Monitoring system
Comprehensive wiring
Refrigeration system Fire control system
Infrastructure
Data center constitutes a full set of complex facilities, including computer system and other supporting equipment (such as communications and storage systems), redundant data communications connection equipment, environment control equipment, monitoring equipment and various security devices.
Modular integrated delivery and joint debugging before leaving the factory
8
III. Application values of micromodule data center
Reduce the initial investment in the Data Center
Centralized monitoring
system
II. Micromodule data center
Power distribution system module High reliability: multiway power supply in the high density rack High adaptability: adapting to various power supply solutions
system
Monitoring system
Integrated Project of machine room
Refrigerat ion
system
Precision air-
conditioner
New fan
Liquid leakage monitoring
Linkage control
Fire control system
Structure system module High reliability: high load-bearing, good cooling effect High adaptability: on-site assembly, rich accessories
II. Micromodule data center
V.S
Traditional IDC Implementation
Raised flooring and complex lighting
Strong and weak current to each rack
New fan system New fan system
Civil construction/ installation work
Decoration work
Large
Strong and
equipment weak cable
installation number-setting
Low voltage distribution
Rack
Air conditioner
installation
installation
Terminal wiring