杭州平安金融中心项目介绍

合集下载

平安金融中心

平安金融中心

Completed in 2017, Ping An Finance Centre is now Shenzhen’s tallest building, also securing status as the second tallest in China and the fourth tallest in the world. The supertall headquarters for Ping An Insurance Company acts as the physical and iconic center of the city’s central business hub, the Futian District. Located on Lot 1 at the southwest corner of Yi Tian Road and Fu Hua Road, the tower connects to both neighboring commercial and residential properties and the Line 1 Gon Wu Gong Yuan metro station. Its height comprises 100 office floors above a retail and conference podium, accommodating 15,500 workers and 9,000 daily passengers to an observation deck.Ping An Finance Centre stands as a stone and glass tower on the northeast corner of its central site, anchoring the entire development. The structure’s stone supports, rendered as chevron-shaped columns, converge at the tower’s height and mediate the tension of the earth to a single point in the sky. Sheathed in glass and stone, the podium is defined by a central atrium that acts as a public vestibule and sun-lit space for meeting, shopping, and dining. Five floors of retail shops terrace away from the tower, forming a large amphitheatre-like space—a new hub for the CBD. In addition, designed for local weather resistance, the tower’s tapered façade reduces wind loads by forty percent and its stainless steel piers form a protective net against lightning strikes.平安金融中心于2017年正式完工,目前是深圳市最高建筑,同是也是中国第二高、世界第四高的建筑。

平安金融中心设计介绍——上部结构篇

平安金融中心设计介绍——上部结构篇

平安金融中心设计介绍——上部结构篇1.结构体系塔楼结构采用巨型钢斜撑外框架+劲性钢筋混凝土核心筒+伸臂钢桁架结构+空间带状桁架+角部V形撑体系.关于平安的结构体系,其实有不同的说法,也有叫“带外伸臂的巨型斜撑框架-核心筒结构”.在全国超限委员会给出的超限审查意见上,结构体系定义为“带伸臂桁架的巨型框架-核心筒结构体系”.再比如,我们曾经做的300米楼,结构体系为“带腰桁架的巨型框架-核心筒结构体系”.不管怎么说,像这种超高层建筑,包括之前已经介绍过的上海中心和上海环球金融中心,抗侧力体系一般由三部分组成:1)外围的巨型框架体系;2)内侧的核心筒体系;3)内外围之间的加强连接,通常采用伸臂的形式.按照这种思路,平安金融中心的抗侧力体系为:1.巨型框架体系:由巨型柱、巨型斜撑、七道带状桁架、角部V型撑2.核心筒体系:底部钢板混凝土剪力墙、上部型钢混凝土剪力墙3.框架体系与核心筒体系间连接:四道伸臂桁架平安金融中心与上海中心高度相当,风力也相当,但上海中心并未加巨型斜撑,这是什么原因?后续再介绍.上海环球金融中心加了伸臂,也加了巨型斜撑,那是因为环球金融中心伸臂未贯穿核心筒,对刚度贡献有限所致.上面两幅图已经清楚显示了抗侧力体系的主要元素,以下分别介绍.2.型钢混凝土巨柱巨柱采用型钢混凝土柱,混凝土强度等级从底部到顶部由C70渐变至C50,钢材等级为Q345GJ.巨柱在平面上近似为长方形,为了与建筑平面协调,其中在一个角部有调整.底部巨柱的尺寸约为6.5mX3.2m,在顶部逐渐减小至3.1mX1.4m.巨柱内埋组合型钢从下至上,厚度由75mm变化至25mm,但在带状桁架层加厚至100mm.巨柱截面形式与上海中心相似,即均接近为“王”字形.3.巨型斜撑在每两个相邻的周边桁架间布置一道巨型斜撑,形成外围的“巨型支撑框架”.该斜撑连接相邻两根巨柱,在每个区,始于下部周边桁架的上弦杆,止于上部周边桁架的下弦杆.角部黄色圆圈,表示轴力/弯矩/剪力在施工过程中释放,以减小弹性变形及短期徐变和收缩的影响.巨型斜撑的设置目的是为了满足巨型框架承担的剪力大于基底剪力10%这一要求.这是北京建研院专家提出的.虽然说上海中心也没有设置斜撑,但由于上海中心的巨柱是不断倾斜的,其巨型框架承担的剪力大于基底剪力的10%.北京专家要硬性执行这条大规定,也提出了三种加强框架剪力的措施:1)将标准层内框架梁加深;2)将巨柱改为斜柱;3)在塔楼立面,玻璃幕墙后加斜撑,斜撑的加设方式又可分为单斜撑和X形斜撑.最后经过计算对比,并与各个专业协调讨论,决定采用单斜撑方案.值得注意的是,单从基底剪力占比来说,上海中心与平安金融中心巨型框架都达到了50%左右.另外,要注意,斜柱轴力水平分量与剪力的区别.事实上,近些年,在广东省,框剪比10%的要求已经越来越淡化,很多项目已经不太关注这一指标.4.核心筒核心筒角部及相交处内埋型钢柱以增加核心筒的延性及刚度.核心筒外墙由地下F5到顶层厚度由1.5m变化至0.5m,其中地下5层~地上12层采用钢板剪力墙结构,周边设置型钢柱、型钢梁约束.核心筒全高设置800mm高的连梁,为满足抗剪条件,大约六分之一的连梁需要内埋型钢加强.同时,在办公楼层需要设置部分双连梁,允许机电设备管道在双连梁之间穿过.平安金融中心组合剪力墙中钢板墙钢板厚度为12~55mm,厚度大于30mm的钢板墙,其竖向缝采用焊接连接,厚度小于或等于30mm的钢板墙,其竖向缝采用高强螺栓连接.钢板墙的四周均需设置型钢框架,以对钢板墙形成约束,加强钢板墙的面外刚度.在楼层标高处、连梁中均设置型钢暗梁,在墙体端部两侧、门洞两侧均设置型钢暗柱,当墙体长度过长时,为满足施工阶段的局部稳定性要求,在钢板墙的面外设置加劲肋,为使柱两侧的混凝土对称浇筑,设置对拉钢筋笼.经计算,本工程构造栓钉的直径为22mm,双向间距为300mm,在型钢框架的斜向位置将栓钉加密一倍,双向间距为150mm.由于钢板将墙体分为两部分,墙体混凝土浇筑时,钢板两侧的混凝土需均匀下料,且钢板两侧混凝土浇筑时高度差不宜过大,以保证钢板的稳定性和定位的准确性.在钢板上开设直径300mm的灌浆流淌孔,以保证两侧的混凝土能顺利流淌.5.空间带状桁架共设置六道空间双桁架、一道单桁架及七道单角桁架,分别位于每个区的避难层或机电层.两层高的外伸臂楼层设置两层高的空间带状桁架及角桁架,其他设备层则设置一层高的空间带状桁架及角桁架.空间带状桁架及平面角桁架与巨柱连接,形成巨型框架.关于带状桁架的设置问题,北京建研院的专家有过讨论.初步设计时,带状桁架为单层,上海中心初步设计时也是单层,由于圆形平面存在扭转,审查时改为空间带状桁架.平安金融中心也一样,专家建议巨型桁架做成空间桁架,角部钢梁也尽可能做成空间桁架,共同形成封闭的环形空间桁架.由于角部桁架对建筑、机电影响较大,最后与专家协调,将角部桁架调整为宽度1.5m的单层带状桁架.6.角部V型支撑在建筑的各个角部设置一个巨型V型支撑.该V型支撑横跨多个楼层,两端分别连接巨柱和角桁架弦杆支座节点,承担角部竖向荷载并提高整体结构的抗侧刚度.7.伸臂沿塔楼全高设置四道钢桁架外伸臂.1、3、5区设备层设置两层高外伸臂,6区设备层设置一层高外伸臂.外伸臂与内埋与核心筒角部的钢柱相连,为了保证外伸臂传力的连续性,外伸臂弦杆贯穿核心筒,同时墙体两侧设置X形斜撑腹杆.根据需要,伸臂可贯通核心筒,也可不贯通核心筒.不贯通核心筒,有可能是因为建筑条件不允许,比如上海环球金融中心,也可能是不必要,比如两三百米的楼,刚宽比较大,不加伸臂,刚度不够,加了贯通型伸臂,刚度过大,在这种情况下,可选择非贯通型伸臂.但是,要注意节点的处理.我们曾参与的一个180米办公楼,核心筒高宽比23,就加的这种非贯通型伸臂.深圳湾有一座350米高的楼,加的也是这种非贯通型伸臂.非贯通型伸臂,有时又称“有限刚度伸臂”.8.结构抗侧刚度贡献上面这个表,抗侧刚度对比的计算指标是由结构顶点位移来确定的.9.重力体系楼面重力支撑体系由钢梁、周边钢柱、核心筒以及巨柱组成.周边的钢柱通过各区的周边桁架进行转换将荷载传递至巨柱.核心筒外部楼面体系为组合楼板和钢筋桁架楼板.典型的办公和交易层楼板厚度为120mm,在核心筒外部四个侧面区域为组合楼板,四个角部区域为钢筋桁架楼板.外伸臂弦杆所在楼层以及所有设备及避难层的楼板厚度为180mm,均采用钢筋桁架楼板.核心筒内部区域为现浇混凝土梁板楼面体系.10.刚重比计算平安金融中心按规范法计算出的刚重比在X向为1.40,Y 向为1.39.按规范,不能满足整体稳定性要求.怎么办?按上海中心的方法进行调整.由于规范规定的刚重比限值是在假定结构质量、刚度均匀的条件下得出的,实际项目可能与此假定偏离较多.平安金融中心质量分布下大上小,大部分质量集中在下部楼层,所以需要在规范法的基础上进行调整.刚重比完整的计算方法在很多文献中都有阐述,感兴趣的可以自行查阅.陆天天等人就上海中心大厦结构整体稳定性的问题,曾专门写过一篇文章,发表在建筑结构学报上.11.楼层最小剪力系数(剪重比)像框剪比一样,在当时,剪重比也是一个硬性指标,平安按7度0.1g设计,剪重比一定要满足0.012.如果要满足这个指标,意味着要将构件截面做得非常大,巨型柱与核心筒墙体就要占据大量的有效使用面积,建筑将无法使用.最后,经全国高层建筑抗震审查专家研究,在适当提高结构刚度的基础上,将要求满足的结构楼层最小剪力系数定为0.0102,然后在小震弹性设计时,全部楼层的楼层剪力按0.012/0.0102=1.176进行放大.现在,剪重比也不是一个硬指标,很多项目,直接根据放大系数进行调整,而不会因为剪重比不够将构件截面加大很多.框剪比、剪重比从诞生之初,就争议不断,很多专家对此都颇有异议,也有不少文献对这些问题进行了讨论,感兴趣的可以去读一读.不可否认的是,通过不断的质疑、讨论、修正,很多概念才逐渐明晰,技术才得以进步.站在现在的角度,看以前项目中曾让我们辗转反侧、寝食难安的问题,我们或许觉得当时有点大惊小怪、有些小题大做,但在当时,那些确实是比较严肃的问题,正是由于当时以及其后大量专家学者的小心论证,才有了今天我们的“胆大妄为”.从某种程度上来说,任何一个“肆无忌惮”的今日,都对应着一个“小心翼翼、如履薄冰”的昨天.技术的进步,难以跳跃.个人的进步也是如此.12.巨型型钢混凝土柱柱脚由于本项目所采用的型钢混凝土截面较大,基于诸多难点,采用有限元法进行柱脚设计.另外,柱脚设计中用到了柱脚锚栓支架.其主要作用是在施工阶段,浇筑底板及承台混凝土时,固定柱脚锚栓,防止其滑动和偏位.支架角钢立柱下底板埋件位于桩顶部,在桩基施工时进行预埋.另外,为保证柱脚的施工安装方便,一般在柱脚周围筏板都预留坑.该预留坑尺寸为4.8X8.0m,在钢骨安装完毕后进行预留坑内的钢筋绑扎,钢筋绑扎完毕后二次浇注.为保证柱脚下混凝土不被压碎,经计算确定,柱脚底板下设置4层双层双向直径40mm的三级钢.13.重力荷载作用下变形分析及控制平安金融中心结构竖向构件主要是8根巨柱和核心筒,且都是内含型钢的钢筋混凝土构件,由于巨柱和核心筒在重力荷载作用下的压应力水平不同、含钢率不同,因此其竖向变形也不同.变形差会对连接两者的伸臂桁架产生附加内力,同时影响楼面的水平度.为消除或降低部分构件在重力荷载作用下的附加内力,主要采取的措施有:1.伸臂腹杆后装,弦杆先铰接后刚接;2.斜撑一端后装;3.带状桁架弦杆所在楼层与弦杆相连的混凝土楼板设后浇带;4.楼面施工荷载不超过2kN/㎡.根据计算结果,主体结构完工时,竖向最大变形发生在中部,位于巨柱的64层和核心筒的59层,对应最大变形分别为87mm和103mm;根据不同阶段核心筒和巨柱的竖向变形差沿楼层分布图,可以看出,底部楼层变形差较小,且随时间增长变化较小;上部楼层由于累积效应及收缩、徐变滞后,变形差增长较快,随着时间增长变形差逐渐增大.结构设计中施工模拟已考虑伸臂桁架腹杆后装,弦杆先铰接后刚接,但没有考虑主体结构完工后核心筒和巨柱竖向变形差对其内力的影响.经过计算,4道伸臂桁架腹杆投入使用20年后由于混凝土收缩、徐变引起的附件内力,与构件材料设计强度的比值为9%~14%.为了补偿竖向构件的竖向变形,可在施工时预留一定高度,使之在设定阶段达到设计标高.在重力荷载长期作用下,巨柱和核心筒竖向压缩变形不同,其预留高度也不同.投入使用1年时,竖向变形基本完成,将此阶段作为竖向构件标高预留高度的计算时间点,通过各层标高预留高度,投入使用1年时竖向构件各层达到设计标高.根据计算,巨柱最大楼层标高预留高度为149mm(79层),核心筒最大楼层标高预留高度为170mm(83层).。

平安金融中心结构设计介绍课件

平安金融中心结构设计介绍课件
12
SOM投标方案
13
FOSTER投标方案
14
高区建筑平面
早期方案 方案报建阶段建筑结构方案
低区建筑平面 15
3、风工程研究
16
平安金融中心风洞试验由RWDI 完成
• To assess the wind environment around the site in terms of safety and comfort
平安金融中心
1、 项目概述 2、 建筑结构体系发展与演变 3、 风工程研究 4、 地震工程 5、 结构设计 6、 巨型结构设计 7、 楼面结构设计 8、 节点设计讨论
1
1、项目概述
2
PROJECT GOALS • Create a tower form which is not only iconic, but intelligent and environmentally responsible. • Minimize the use of energy and materials by designing an aerodynamic form and efficient structure.
PAIFC is applying for LEED Gold status.
3
Design overview
•Site location
4
•Building area and section organization
5
•Podium roof terrace •Podium atrium

•Typical office layout
serviceability • 评估塔楼风致振动舒适性品质
17
Test Method试验方法 High-Frequency Force Balance Technique (HFFB)高频测力天平技术

平安金融中心结构设计

平安金融中心结构设计

50
大震作用下,部分杆件开始出现局部屈 服,但未达到极限强度。最高应力发生 在外伸臂斜杆与节点板相交处局部区域, 最高应力约为395N/mm2。
由伸臂桁架、周边桁架、巨型斜支撑及 巨柱钢骨连接而成的节点在给定的地震 作用下的有限元分析结果可知,在设防 烈度作用下,节点区应力未达到屈服, 伸臂桁架和周边桁架各杆件也未屈服。 在罕遇地震作用下,伸臂桁架以及伸臂 桁架与巨柱钢骨连接处的应力较大,部 分杆件开始屈服,但未达到极限强度
38
空间带状桁架设计
带状桁架采用空间带状桁架。 考虑竖向地震。 中震弹性设计。 桁架上、下弦杆、腹杆地震作用效应放大1.5倍。 杆件应力比小于等于0.85。 带状桁架设计不靠虑巨型斜撑的作用。
39
巨型斜撑设计
中震弹性设计。 地震作用效应放大1.3倍。 杆件应力比小于等于0.85。 考虑模拟施工、混凝土收缩、徐变对其的影响。
大震下的应力图
51
施工阶段结构验算
本工程施工周期较长,项目所在地台风频发,因此有必 要进行施工期间的抗风分析。按照上述施工步骤,伸臂桁架 腹杆等构件后安装,后安装之前结构侧向刚度较弱,是一个 比较不利的阶段,考虑在此阶段进行抗风分析。 刚度和强度满足以下性能设计指标:强度和刚度验算时取10 年一遇风荷载,最大层间位移角按1/500控制。
不含倾斜巨柱轴 力分量的外框剪 力 21% 25% 22% 15% 15% 12% 14% 21% 20%
增加巨型斜撑后,巨型框架承担的剪力相应增加约20%以上。
45
节点设计
节点分析和设计的基本原则及目标是:
采用“强节点弱构件” 的设计原则。 正常使用状态、小震和风荷载作用下节点处于弹性状态。 在中震下节点保持弹性。 在大震下节点不破坏,个别节点进入屈服工作阶段。 采用ABAQUS进行节点分析与设计。

东方巨塔深圳的平安金融中心的建设与发展

东方巨塔深圳的平安金融中心的建设与发展

东方巨塔深圳的平安金融中心的建设与发展深圳作为中国改革开放的窗口城市之一,一直以来都在积极推动金融业的发展。

其中,东方巨塔深圳平安金融中心作为重要的金融地标,扮演着举足轻重的角色。

本文将对东方巨塔平安金融中心的建设与发展进行全面分析与探讨。

一、建设背景与规划东方巨塔深圳平安金融中心的建设源于深圳市政府对金融业的战略规划和发展需求。

作为一座现代化的金融中心建筑,其定位是为了推动深圳金融业的国际化进程,提升深圳在全球金融市场的影响力。

在规划阶段,东方巨塔平安金融中心以可持续发展为核心理念,注重生态环境与资源的合理利用。

建筑设计充分考虑了空间布局、能源利用、生态环境等多个方面的因素,力图打造一个既符合金融功能需求,又环保节能的现代化金融中心。

二、建设过程与特色东方巨塔平安金融中心的建设过程经历了多个阶段,从前期规划到设计审批,再到土地开发与建设等。

在每个阶段,相关部门积极配合,确保项目能够顺利推进。

该金融中心的特色主要体现在以下几个方面:1. 高层建筑:作为一座摩天大楼,东方巨塔以其独特的外观设计和超高的建筑高度吸引了众多目光。

其标志性建筑风格彰显了深圳现代化城市的形象。

2. 全方位金融服务:东方巨塔平安金融中心为广大金融机构提供了全方位的服务空间。

不仅有办公场所,还包括会议中心、培训中心、金融展览馆等功能区域,为金融从业人员提供了一个综合性的工作平台。

3. 先进科技应用:在建设过程中,东方巨塔引入了先进的科技应用,如人工智能、物联网等。

这些技术的应用不仅提高了建筑的智能化程度,也优化了金融服务的效率。

4. 前沿绿色建筑理念:东方巨塔平安金融中心积极倡导绿色建筑理念,通过引入节能设备、优化空调供应系统等手段,降低能源消耗,减少对环境的影响。

三、发展成果与展望经过多年的建设与发展,东方巨塔深圳平安金融中心取得了显著的成果,不仅给深圳的金融业发展带来了强大的动力,也为国际金融市场注入了新活力。

具体来说,东方巨塔的建成使得深圳的金融机构汇聚于此,形成了独具特色的金融生态圈。

[精品文档]超高、超长建筑结构设计若干关键技术(傅学怡)

[精品文档]超高、超长建筑结构设计若干关键技术(傅学怡)

超高、超长建筑结构设计若干关键技术(傅学怡)中建国际设计顾问有限公司总工程师傅学怡我给大家介绍一下最近我们做的项目中我觉得一些比较关键的技术,主要讲三个内容:一是新高规即将颁布了,其中有一条,在做动力弹塑性分析前,必须要做施工全过程模拟,带着这样一个比较符合实际的重力荷载的工况和状态,进入弹塑性分析。

我在这里讲一下施工全过程模拟与施工控制,以中钢国际广场为例。

二是重力荷载下长期变形以及长期变形的控制,以平安国际金融中心为例。

三是超长结构的温度收缩效应分析与控制,以已竣工的深圳北站为例。

案例:中钢国际广场中钢国际广场将近40万平米,主楼84层,358米,主要特点是在下部1/2高度以下采用六边形编制的窗洞构成外网筒结构,建筑师不允许里面再加柱子,针对六边形外网筒结构我们做了一些工作,下面我把结构构成的情况跟大家说一下。

我们有内筒,底下的厚度是1.15米,到了上面变成500,现在做住宅,只要有楼梯、有电梯都是混凝土墙去封,但是超高层这么去封是不合理的,因为自重就很大了,所以我们把墙相对的集中、对称,同时受力、延性、承载力等方面都会有所改善。

内筒的构成跟国贸三期一样,采用内层钢板,但内层钢板在设计上已经有预留在钢板两翼的混凝土连接的预留孔,预留孔里要放构造、穿芯钢筋,同时钢板上要布置栓钉,栓钉按照钢板剪力墙的主应力,在主应力方向多配,应力小的部位少配。

整个结构的构成,上部是矩形钢管的菱形网格,中部是一个过渡,下部是六边形,上部菱形是酒店,每个房间的窗户正好在中间,窗户上没有构件,下部是六边形网格。

楼面环梁有两种类型,主要是根据建筑的需要,类型1要往里退,玻璃窗才能装。

我们在六边形网筒上做了两件事情,第一件事情是角部斜柱,正六边形应该都是120度,这里把它放大到130多度,它跟直线的夹角改为18度,可以节省钢材,改善受力,这些都经过详细论证。

第二件事是把非楼面横梁做了刚度的优化,国外没有已建工程,但有这方面的方案,六边形是六条边相等的,我们做的是不等的,这里包括两个不等,一是夹角到角部扶正,二是在六边形横梁上刚度适当弱化,六边形横梁相当于剪力墙的连梁,主要是传递水平力,不传递竖向力,因此给它适当地弱化,有利于提高整体结构的延性,同时不改变结构的受力性能。

2017平安国际金融中心案例沉淀

2017平安国际金融中心案例沉淀

项目概况分析
设计方案
KPF投标方案
项目概况分析
设计方案
SOM投标方案
项目概况分析
设计方案
FOSTER投标方案
项目概况分析
最终方案
原设计高度660米,因航空限高要求 “缩水”至592.5米;缩减的约60米部分主要是取消塔尖的“天线”装 置,并不影响原有的主体设计,但也无缘挑战中国第一高楼记录
原设计方案
现方案
CCDI投标方案
“天线被摘”
广州地标小蛮腰也曾临时调整高度,原 方案确定的高度是610米。而经过空管 部门完成机场评估并与政府协调后,缩 减到600米以下。缩减的主要方式,也 是削天线。为此不得不多耗资一千多万, 工期拖延几个月。
项目概况分析
设计管理组织结构
平安与主设计方签订合约,专业设计方分与主设计方签订合约,项目实行纵向管理
1-10层
4.5m
3.0m
地下1200个
500-550元/㎡/月 45元
规定自持60%,60层以下,100层以上自用,其余出租
2016年3月18日
CCDI
中国平安人寿保险股份有限公司
仲量联行
项目概况分析
开发背景
平安集团原计划于原高交会馆位置建设企业总部,但由于容积率和高度的限制,后于2007年11月6日以 16.568亿元竞得深圳市福田区01号地块,自筹建设资金90亿,计划打造深圳最高水准的摩天大厦
中国平安人寿保险股份有限公司成立于2002年,是中国平安保险(集团)股 份有限公司旗下的重要成员。从规模保费来衡量,是目前国内第二大寿险公司。
建设开发目的分析:
企业自身发展需求 20年,6000亿 建成国际领先的综合金融服务集团
企业品牌形象需求 展现实力,推动深圳金融行业发展

杭州钱江新城国际金融中心(B08地块)项目开发报告

杭州钱江新城国际金融中心(B08地块)项目开发报告

杭州钱江新城国际金融中心(B08地块)项目开发报告项目开发构思第一部分杭州的理想:打造区域金融中心杭州早在2004年《政府工作报告》中即首次提出“以增强中心城市综合服务功能为重点,加快进展现代服务业。

大力进展金融业,培养本地金融机构,同意上海金融业的辐射与合作,吸引外资银行、保险机构来杭设立分支机构,将杭州建设成为长江三角洲南翼的区域金融中心”的工作思路。

在这一工作思路的指导下,全市经济社会各项事业在取得快速健康进展的大背景下,金融事业也呈现出了欣欣向荣的喜人局面。

2006年杭州市金融业增加值增长28.8%,各类存款余额为7855.55亿元,增长17.3%;各类贷款余额6603.86亿元,增长20.1%。

2007年1—4月,各类存款新增570亿元,各类贷款新增640亿元。

杭州金融业在进展过程中表现出的良好状态固然可喜,但从打造区域金融中心角度而言,其仍存在着诸如硬件与软件上的不足,需要政府及各有关企业给予持续性的关注与推动。

一、杭州金融业进展的三个显著特征1、金融生态良好据中国社科院的统计分析,杭州金融生态排名全国第四位,在市场化、投资多元化、产业进展与信用程度等方面占有优势。

2、金融机构集聚度较高目前在杭银行机构共有24家、外资银行办事处2家(汇丰银行、东亚银行)。

国内要紧金融机构大都在杭设立分支机构,80%以上汇聚在庆春路,庆春路号称杭州的华尔街。

上图为香港汇丰银行大厦上图为东亚银行大厦3、金融业效益良好多年来存贷款一直保持“高收益、低风险”,银行业绩、进展速度连续多年处于全国领先地位,金融界的“杭州现象”引起了全国的广泛关注。

二、杭州金融业进展存在的不足之处1、从金融功能角度看,杭州金融业已较好地发挥了便利交易、动员储蓄、配置资源三大功能,但在促进公司治理、便于风险管理二大功能方面还尚显不足。

2、杭州金融业进展还存在“三低”,即金融业产值化程度低、金融市场化程度低,金融国际化程度低。

3、从金融对地方经济的奉献看,杭州金融业在通过资本集聚与资源配置在间接促进经济增长方面已作出了很大的奉献,但作为一个产业,在产值、税收、就业等方面对经济进展的直接奉献相对较弱,只是略高于全国平均水准。

高层建筑分析--深圳平安金融中心ppt课件

高层建筑分析--深圳平安金融中心ppt课件
还采用了高空 取新风措施(左 图)
高层低温新 风措施(右图)
.
5.结构体系与工作性能解析
典型标准层结构布置
.
典型机电层结构布置
5.结构体系与工作性能解析
5.1 超限审核前后结构体系变化:
.
5.结构体系与工作性能解析
5.2 竖向的结构支撑
标准办公层的结构模型示意
.
5.结构体系与工作性能解析
5.3 竖向结构体系模型分析:
1.项目概况
平安国际金融中心项目位于深圳 市福田区01号地块,益田路与福华路 交汇于西南角。项目地块西侧与低密 度购物公园COCOPARK相邻,其间以 中心二路相隔。项目东南向望是深圳 最大的会议展览设施—深圳会展中心。 项目用地南北长约175.40米,东西方 向进深约88.00米~133.00米。规划中 的用地性质为办公,商业和相应的配 套设施。根据规划要求,建设用地指 标如下:
.
3.空间构成合理性分析
3.1 竖向由下往上分一个底层大堂,两个空中 大厅,7个标准层区和顶层的观光层。其各层交 通流线如下图:
.
3.2 办公区的交通流线:
3.空间构成合理性分析
.
3.空间构成合理性分析
3.3 竖向交通组成.来自3.4 核心筒平面布局
3.空间构成合理性分析
.
3.空间构成合理性分析
全世界有200多座高层和超高层建筑是KPF的设计,在中国,包括108层的香港九 龙车站大厦、480米高的香港环球贸易广场、492米高的上海环球金融中心、288米高 的上海恒隆广场等。
该项目规划设计为南北塔楼,其中,裙房高度不低于40米,南塔楼高度设计 为150—200米之间,北塔楼设计高度不低于450米。 这个高度将超过深圳的最高位于蔡屋围的100层441.8米高的“京基100”和 383.95米的“地王大厦”,成为深圳第一高楼。 据了解,之前规划中平安集团总部所在地为原高交会馆位置,但由于容积率 和高度的限制,平安选择了这块深圳市中心区CBD最高建筑用地,用来打造 深圳最高水准的摩天大厦。

节水技术在超高层建筑设计中的应用——以杭州平安金融中心为例

节水技术在超高层建筑设计中的应用——以杭州平安金融中心为例
Ke y w or d s : wa t e r s a v i n g t e c h n o l o g y ; u l na h i g h — r i s e b u i l d i n g ; L EE D; g r e e n a r c h i t e c t u r e
L I J i a n g - t a o
( P i n g An Re a l E s t a t e C o mp a n y L t d , S h a n g h a i 2 0 0 1 2 0 , C h i n a )
Ab s t r a c t : he T p r o j e c t o fHa n g z h o u
a n d l a nd s c pe a i r r i ga ti o n a r e u t i l i z e t h e wa te r — s a v i n g s ni a t ry a wa r e a n d v a l v e pi pe wi t h h i g h q u a l i t y a r e
An F i n a n c i a l C e n t e r l o c a t e s i n t h e c o r e a r e a f Ha o n g z h o u
Q i a n j i a n g N e w C i t y , t h e u l t r a h i g h - r i s e b u i l d i n g i s 1 8 0 m e t e r s h i g h , w h i c h i s a l s o o n e f o t h e k e y w te a r - s a v i n g p r o j e c t s i n Ha n g z h o u . I n o r d e r t o a c h i e v e t h e a p p l i c t a i o n f o w t a e r - s a v i n g t e c h n o l o g y i n h i g h - r i s e b u i l d i n g s , w e a d o p t e d t h e c o l l e c t i o n—p r o c e s s i n g—u t i l i z t a i o n s y s t e m f o r t h e r a i n w a t e r a n d t h e c o n d e n s a t e

SPM_平安金融中心项目_施工管理阶段_主体结构施工方案_49地下室试验检验方案

SPM_平安金融中心项目_施工管理阶段_主体结构施工方案_49地下室试验检验方案

SPM_平安金融中心项目_施工管理阶段_主体结构施工方案_49地下室试验检验方案地下室是一个建筑物的重要组成部分,承担着支撑建筑物重量、提供车辆停放和设备存放等功能。

在平安金融中心项目中,地下室的安全性和稳定性尤为重要,因此在施工管理阶段要进行地下室结构的试验检验,以确保其质量和安全性。

1.地下室结构施工方案地下室结构施工方案是地下室施工的重要依据,通过编制施工方案,可以有效地组织施工活动,保证施工质量。

地下室结构施工方案应包括以下内容:(1)地下室结构设计图纸和技术规范:施工方案应符合设计图纸和相关技术规范的要求,确保施工过程中的设计一致性。

(2)施工组织设计:包括施工单位组织结构、施工人员配备、施工流程和工期计划等内容,确保施工活动按计划进行。

(3)施工方法和工艺:包括地下室结构施工的具体方法和工艺流程,确保施工质量和安全。

(4)材料选用和质量控制:对地下室结构施工所使用的材料进行详细说明,包括材料的规格、型号、生产厂家等信息,并制定质量控制措施,确保材料质量符合要求。

地下室试验检验是地下室结构完成后的重要工作,通过试验检验可以评估地下室结构的质量和安全性,及时发现问题并进行处理。

地下室试验检验方案应包括以下内容:(1)试验检验范围:确定地下室试验检验的范围,包括地下室结构的各个部分和连接部位。

(2)试验仪器设备:确定适用于地下室试验检验的仪器设备,包括非破坏检测设备、压力传感器、位移传感器等。

(3)试验检验方法:确定地下室试验检验的具体方法,包括静载试验、动力荷载试验、温度湿度试验等。

(4)试验检验标准:确定地下室试验检验所需符合的标准,包括国家标准、行业标准等。

(5)试验检验程序:制定地下室试验检验的详细程序,包括试验前的准备工作、试验过程及监测记录、试验后的数据分析和结论形成等。

3.地下室试验检验的实施步骤在实施地下室试验检验时,应按照以下步骤进行:(1)准备工作:确认试验检验的范围和内容,准备试验仪器设备和人员,制定试验检验方案。

平安金融中心比春笋高多少

平安金融中心比春笋高多少

平安金融中心比春笋高多少
平安金融中心位于中国深圳市福田区,是一座高层建筑。

该建筑高度为597米,共有116层,其中地上层数为115层,地下1层。

平安金融中心建筑面积约为37
万平方米,其中办公面积约为21万平方米,商业面积约为3.6万平方米,酒店面
积约为1.5万平方米,公寓面积约为9.5万平方米。

该建筑于2017年5月已经开始建造,2019年11月正式完工并投入使用。

与平安金融中心相比,春笋的高度是相对较低的,因此无法与平安金融中心进行直接比较。

春笋是一种植物,其高度约为20-30厘米左右,是春季生长较快的一种植物,因此被用来比喻生命力旺盛,具有极高的象征意义。

在城市建筑领域,平安金融中心的高度是举世罕见的,是一个极具标志性的建筑,也是中国乃至全球城市建筑的骄傲之一。

现代建筑的奇迹中国深圳的平安金融中心

现代建筑的奇迹中国深圳的平安金融中心

现代建筑的奇迹中国深圳的平安金融中心现代建筑的奇迹:中国深圳的平安金融中心深圳,作为中国改革开放的重要城市,以其独特的城市发展模式和创新能力在世界范围内赢得了口碑。

它拥有许多令人惊叹的现代建筑,其中最为著名的之一就是平安金融中心。

作为一座代表深圳现代化的地标建筑,平安金融中心不仅以其壮观的外观和独特的设计引人注目,更体现了中国对于可持续发展和绿色建筑的体现。

平安金融中心位于深圳湾核心地段,毗邻香港,是一座综合性的超高层建筑。

该建筑主体高度达到600米,共有116层,其中包括办公楼、酒店、会议中心以及观景台等功能。

整个建筑项目的规划和设计始于2014年,历时五年才正式竣工。

平安金融中心的建筑风格兼具现代与未来感,充分展示了深圳作为创新城市的形象。

作为一座现代建筑奇迹,平安金融中心在建筑设计上融合了许多创新元素。

首先,它采用了先进的建筑结构技术,如超高层建筑防震设计、风洞试验等,确保了建筑在恶劣天气和地震等情况下的安全性。

其次,建筑外立面采用了大量的玻璃幕墙,不仅提供了优美的视觉享受,还能够最大限度地利用自然光照,减少能源的消耗。

此外,建筑内部采用了智能化系统,包括自动化的电梯、照明和空调系统等,以提高工作效率和员工的舒适度。

平安金融中心不仅在外观设计上独具匠心,更在环保和可持续发展方面发挥了重要作用。

建筑设计中充分考虑了环境保护和资源节约,采用了多种绿色建筑技术。

例如,建筑采用了材料回收与再利用的原则,减少了对自然资源的消耗。

同时,建筑还配备了雨水收集系统和太阳能发电系统,以实现雨水的循环利用和减少对传统能源的依赖。

这一系列的设计理念和实践使平安金融中心成为了一座典范的绿色建筑,体现了中国在可持续发展方面的积极探索。

除了在建筑设计和环保方面具有突出贡献外,平安金融中心也在城市发展中发挥了重要的引领作用。

作为深圳湾核心地段的标志性建筑,它将吸引国内外的游客和投资者,进一步推动深圳的经济发展和国际影响力。

SPM_平安金融中心项目_施工管理阶段_主体结构施工方案_54地下室楼板预留钢筋成品保护措施

SPM_平安金融中心项目_施工管理阶段_主体结构施工方案_54地下室楼板预留钢筋成品保护措施

平安金融中心PINGAN FC地下室楼板预留钢筋成品保护措施平安金融中心项目部2012年02月21日目录一、编制依据 (1)二、编制目的及适用范围 (1)2.1编制目的 (1)2.2适用范围 (1)三、工程概况 (1)3.1设计概况 (1)3.2地下室结构概况 (1)3.3地下室钢筋概况 (2)四、预留钢筋成品保护措施 (3)4.1预留长度 (3)4.2保护措施 (3)4.3已破坏钢筋处理 (4)二、编制目的及适用范围2.1编制目的本工程地下室结构复杂,梁、柱、墙预留钢筋多,而每一结构层必须在其上方支撑拆除后才能施工,故预留钢筋成品保护困难。

为了更好地指导施工,保护预留钢筋受支撑拆除或其他因素破坏,特编制此方案。

2.2适用范围本施工方案适用于地下室梁、柱、墙体、楼板的钢筋预留保护。

三、工程概况益田四、预留钢筋成品保护措施4.1 预留长度本工程地下室结构钢筋接头形式选择的基本原则如下: 1、直径d ≥20采用直螺纹连接,直径d <20绑扎搭接。

2、框架柱、剪力墙、剪力墙边缘构件、转换大梁的纵筋、框架梁主筋均采用直螺纹连接。

3、同一连接区段内搭接钢筋面积百分率:直螺纹连接≤50%;绑扎搭接≤25%(梁、板、墙);绑扎搭接≤50%(柱)。

根据以上原则对于地下室构件不同连接方式的预留插筋按照国家相关规范图集留设至相应长度,无特殊说明无需加长,留设时注意钢筋错头。

4.2 保护措施1、在拆撑前用铁丝将相邻的几根插筋绑扎成束。

然后将成束的钢筋弯曲至1m 高(弯曲钢筋时尽量增大弯曲弧度,避免弯曲时开裂),再用木板支设一个木箱将钢筋罩住。

如下图所示:木箱钢筋2、支撑拆除后,用小型机械运输渣土时,均应避开插筋不得碾压破坏插筋。

4.3 已破坏钢筋处理1、墙柱插筋能够调直的尽量调直,尤其是柱钢筋应尽量保证其原有预留长度。

2、不易调直的钢筋切割至表格中所示留置长度后再调直,切割后接头应平齐,以后按100%接头搭接上部钢筋,搭接长度满足1.6Lae。

平安银行股份有限公司信用卡中心杭州分中心介绍企业发展分析报告

平安银行股份有限公司信用卡中心杭州分中心介绍企业发展分析报告

Enterprise Development专业品质权威Analysis Report企业发展分析报告平安银行股份有限公司信用卡中心杭州分中心免责声明:本报告通过对该企业公开数据进行分析生成,并不完全代表我方对该企业的意见,如有错误请及时联系;本报告出于对企业发展研究目的产生,仅供参考,在任何情况下,使用本报告所引起的一切后果,我方不承担任何责任:本报告不得用于一切商业用途,如需引用或合作,请与我方联系:平安银行股份有限公司信用卡中心杭州分中心1企业发展分析结果1.1 企业发展指数得分企业发展指数得分平安银行股份有限公司信用卡中心杭州分中心综合得分说明:企业发展指数根据企业规模、企业创新、企业风险、企业活力四个维度对企业发展情况进行评价。

该企业的综合评价得分需要您得到该公司授权后,我们将协助您分析给出。

1.2 企业画像类别内容行业空资质空产品服务银行业监督管理委员会依照有关法律、行政法规1.3 发展历程2工商2.1工商信息2.2工商变更2.3股东结构2.4主要人员2.5分支机构2.6对外投资2.7企业年报2.8股权出质2.9动产抵押2.10司法协助2.11清算2.12注销3投融资3.1融资历史3.2投资事件3.3核心团队3.4企业业务4企业信用4.1企业信用4.2行政许可-工商局4.3行政处罚-信用中国4.5税务评级4.6税务处罚4.7经营异常4.8经营异常-工商局4.9采购不良行为4.10产品抽查4.12欠税公告4.13环保处罚4.14被执行人5司法文书5.1法律诉讼(当事人)5.2法律诉讼(相关人)5.3开庭公告5.4被执行人5.5法院公告5.6破产暂无破产数据6企业资质6.1资质许可6.2人员资质6.3产品许可6.4特殊许可7知识产权7.1商标7.2专利7.3软件著作权7.4作品著作权7.5网站备案7.6应用APP7.7微信公众号8招标中标8.1政府招标8.2政府中标8.3央企招标8.4央企中标9标准9.1国家标准9.2行业标准9.3团体标准9.4地方标准10成果奖励10.1国家奖励10.2省部奖励10.3社会奖励10.4科技成果11 土地11.1大块土地出让11.2出让公告11.3土地抵押11.4地块公示11.5大企业购地11.6土地出租11.7土地结果11.8土地转让12基金12.1国家自然基金12.2国家自然基金成果12.3国家社科基金13招聘13.1招聘信息感谢阅读:感谢您耐心地阅读这份企业调查分析报告。

平安金融中心结构设计与研究

平安金融中心结构设计与研究

目的
本次结构设计的目的是为了满足平安金融中心在安全性、实用性和美观性方 面的要求。具体来说,设计者希望通过优化结构设计,提高建筑的抗风、抗震能 力,同时注重节能环保,降低能耗。最终,为业主和用户提供一个安全、舒适、 高效的建筑环境。
理念
本次结构设计的基本理念包括以下几点: 1、结构体系:采用钢-混凝土混合结构体系,以应对深圳地区的地震活性。
1、对复杂地质条件的适应性研究:针对深圳地区复杂的地质条件,研究如 何提高结构设计对地质风险的适应性。
2、结构优化设计研究:通过精细化建模和性能分析,研究如何进一步提高 结构的安全性和经济性。
3、智能结构设计研究:结合先进的技术手段,研究如何实现结构设计的智 能化和精细化。
4、可持续结构设计研究:探讨如何将绿色建筑理念和可持续发展的思想融 入到结构设计中,提高建筑的使用价值和环保性能。
参考内容二
作为世界上最高的建筑之一,上海环球金融中心以其独特的结构设计吸引了 众多眼球。本次演示将从结构设计、钢结构、玻璃幕墙和楼梯设计等方面,深入 探讨上海环球金融中心的结构设计。
一、结构设计
上海环球金融中心的结构设计充分展现了现代建筑的独特魅力。建筑整体呈 正方形,外立面呈现曲线形态,寓意着海纳百川、有容乃大的精神。在内部空间 布局上,环球金融中心注重功能性设计,使得办公、商业和观光等空间都能够得 到合理的利用。
平安金融中心的结构设计采用了常见的框架-核心筒结构体系。该结构体系 具有较高的承载力和抗侧刚度,能够满足超高层建筑的使用要求。在设计中,采 用了多种软件进行结构分析和优化,如SAP2000、ANSYS等。同时,也考虑了多种 因素对结构设计的影响,如环球金融中心的结构设计是一项令人瞩目的伟大工程。它汇聚了 人类的智慧与创造力,展现出令人惊叹的艺术美感。作为一个欣赏者,我们应当 对这样杰出的结构设计表示敬意,并从中汲取灵感,为未来的建筑事业注入更多 的活力和创意。

平安金融中心南塔项目给水设计简介

平安金融中心南塔项目给水设计简介

平安金融中心南塔项目给水设计简介摘要:平安金融中心南塔项目作为深圳的标志性建筑之一,建筑功能复杂涵盖了商业、办公、酒店等多种性质。

其建设过程是建设各方通力合作的过程,也是设计方案不断调整、修改、完善和思考的过程。

本文结合改项目的具体情况,进行各系统的简介及思考,为以后类似项目的给排水及消防设计提供参考。

1、项目概况平安金融中心南塔位于深圳市福田中心区CBD核心地段,益田路与福华三路交汇处。

项目北侧为平安金融中心北塔(深圳最高楼结构高度598m),其间以福华三路相隔;项目地块西侧与星河国际花城相邻,其间以中心二路相隔。

平安金融中心南塔高277.3m,塔尖约293米,基地面积11507.28m2,总建筑面积191000m2。

本项目由5层地下室,49层塔楼组成,拟建成一个集顶级写字楼,商业及高端酒店(柏悦酒店)为一体的综合性项目。

2、系统简介给水系统是给排水系统设计中的主要耗能系统,给水形式的选择、给水系统的分区,都需结合项目的实际情况及各用水点的用水性质、运行能耗、市政供水情况综合考虑决定。

3、给水系统本项目处于城市中心区,周边市政管网条件优良,常年实测市政压力稳定在0.35MPa。

结合项目的实际情况,对项目给水系统进行了合理分区,具体如下:3.1设计中的问题和解决办法本项目涉及多个业态,功能性质复杂,各业态的用水时间、周期性、水质要求均由区别,同时未来的物业管理方可能是多个物业。

在此前提下,该如何去设置加压泵房,设计团队进行了深入的探讨,根据业态将各加压泵房进行了区分。

同时根据柏悦酒管要求酒店贮存水量采用最高日100%预留。

办公及商业生活水箱有效容积按最高日用水量25%计算,酒店生活水箱有效容积按最高日用水量100%计。

在B5商业生活水泵房设置120m3生活水箱,B5办公生活水泵房设置75m3生活水箱,B5酒店生活水泵房设置生活水箱共650m3,其中原水箱为440m3,净水箱为210m3;L21层设置办公生活水箱12m3,酒店生活转输水箱36m3;L32层设置办公生活水箱12m3;M1层设置酒店生活水箱16m3;生活水箱均分为两格。

平安金融中心比春笋高多少

平安金融中心比春笋高多少

平安金融中心比春笋高多少平安金融中心比春笋高多少?这个问题牵涉到两个具体的建筑物,因此需要仔细观察和比较,才能得出正确的答案。

以下是我对这两座建筑物的分析和比较:一、平安金融中心:1. 项目简介平安金融中心是广州市海珠区中心区域的标志性建筑,共有116层,总高度达到599米,是广州市现在最高的建筑物,也是中国第二高的建筑物。

2. 建筑设计平安金融中心的外型呈锥形,高耸入云,整体造型流畅美观。

各层楼之间的过渡非常顺畅,完美地体现了建筑的艺术性和功能性。

整个建筑大量采用玻璃幕墙材料,不仅视野开阔,而且明亮舒适,让人感到非常舒适。

3. 使用功能平安金融中心主要是作为金融、商务、写字楼等多重功能综合体的集合。

整个建筑内部秉承着高科技和现代化的理念,拥有完善的供暖、通风、照明和配套设施。

这里还拥有酒店、商场等生活娱乐设施,让人们在办公之余享受到丰富多彩的生活。

二、春笋:1. 项目简介春笋是一种著名的趣味游戏项目,由竹子制成,玩家需要掌握一定的技巧才能将所有春笋抽出来。

相较于平安金融中心,春笋的高度显然远远不及。

2. 建筑设计春笋的建筑设计十分简单,主要由许多竹子组成,整体造型呈长圆锥形,每组竹子的顶端连在一起形成一个顶点。

不同之处在于,春笋的竹子上是有纹路的,让玩家在操作时更易抽出。

3. 使用功能春笋是一种趣味游戏,使用功能也只是娱乐和消遣。

至此,我们对两个项目的简介、建筑设计和使用功能都做了比较。

根据上述几方面的分析,我们可以得出结论:平安金融中心远高于春笋,高度的差距应该在500米以上。

同时,平安金融中心不仅外形艺术,而且兼顾了实用性,有着多种使用功能;春笋则只是一种娱乐设施,使用功能单一。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
4
5
钱江新城区位
钱江新城 代表了新世纪杭州 大都市的形象和风貌。如果说, “西湖时代”是“三面云山一面 城”的城市格局,那么钱江新城 ,就是以钱塘江为依托的宽阔城 宇,它的特点就应体现是现代、 开阔、大气、高度,并在规划布 局 、建筑设计、建筑风格等方 面体现钱塘江特色,同时孕含杭 州的灵气、文化、历史、个性和 特色。建成的钱江新城正在且必 将成为杭州,乃至浙江的金融、 政务及商务中心。
浙商证券
建设银行
华夏 银行
北京 中信 银行
杭州国际会议中心 杭州城市阳台 杭州大剧院
民泰商行
银监局 保监会 工商银行 浙商银行 华融租赁 新华期货
富春路
农业银行
联合 金融
交行



N
日趋成型且不断壮大的浙江省省级金融街区,金融大鳄聚集之地,钱江之畔的曼哈顿
11
项目工程概况
24
合作团队
➢ 环境规划设计顾问——AECOM 艾奕康环境规划设计 AECOM 是提供专业技术和管理服务的全球咨询集团,作为《财富》500强公司之一,业务遍及全球100多 个国家,年营业额超过60亿美元,在中国的香港、深圳、上海、北京、重庆、南昌等地设有15个办公室。 美国《工程新闻记录》(ENR)杂志2010年度500强设计公司排名中,AECOM综合排名位列第一。
28
区位优势— 轨道交通
轨道交通直达,便捷高效交通
钱江路 清 江 路
地铁双线环绕
项目 庆 春 路
富春路
4号线
BRT9号线 (规划中)
2号线
钱塘江 N
项目边地铁站有2、4号线换乘站江锦路站及4号线站点。
29
区位优势—商业氛围
来福士广场—总建筑面积约40万平方米, 业态组成:办公、星级酒店、服务公寓、 购物中心(2015年开业)
2013年6月 开工
2017年3月 竣工
2015年6月 正负零
2017年8月 入驻
12
13
项目规划方案
塔楼C
塔楼B
塔楼A(平安自用)
设计总平面图
项目
用地面积: 总建筑面积 地上建筑面积
其中: A:
地上总建筑面积: 建筑高度: 层数 B:
地上总建筑面积: 建筑高度: 层数 C:
地上总建筑面积: 建筑高度: 层数
➢ 机电顾问公司——Arup奥雅纳 Arup奥雅纳工程顾问总部位于英国伦敦,现已在全球38个国家和地区设立了90多个分支机构,拥有逾 11,000名规划、作为国际性多元化的工程顾问机构,提供总体规划、经济评估、可行性研究、具体设计、项 目管理、施工监理等服务,在大中华地区具有超过35年的丰富经验,为当地客户提供全面的设计、工程、规 划和咨询服务。我们参与建设了众多标志性建筑,包括北京的“鸟巢”和“水立方”、香港昂船洲大桥以及 台北艺术中心等。
国际知名物业管理公司 2017年上半年 4F + 23F 44797
写字楼地上建筑面积(㎡ )
43073
商业面积(m2) 其它用房面积(m2)
1306 417
标准层面积 (㎡ )
约1,980
得房率%
75.29%
平面房型
方正,环形走廊,利于分割
楼层净高 (m)
2.7
架空地板高度(mm)
110
空调系统 电梯总数量 ( 台)
得房率%
75.29%
平面房型
方正,环形走廊,利于分割
楼层净高 (m)
2.8
架空地板高度(mm)
110
空调系统 电梯总数量 ( 台)
二管制风机盘管
12客梯(进口电梯)+2台消防梯 +2台转换梯
17
技术经济指标—塔楼B
净高、层高
净高2.8米,层高4.2米(其中31F 15F 为4.3m均为交易层)
为4.35m、
二管制风机盘管
10客梯(进口电梯)+2台消防 梯+2台转换梯
19
技术经济指标—塔楼C
布局与结构
净高、层高
净高2.7米,层高4.2米(其中11F 为4.2 为交易层)
结构 框架-核心筒结构
外立面 单元体玻璃幕墙
楼板承重 250kg/㎡
铝板 裙房部分高级穿孔铝板
幕墙系统

玻璃幕墙 低辐射双银LOW-E中空夹胶玻璃

双路供电,消防和重要设备末端自动切
经 济 供电系统
电力供应 换,重要开关箱设电器火灾漏电报警系 统

供电量标准 设计平均电力标准层:80KVA/㎡

空调种类 二管制风机盘管
空调主机系统
地下室设机械排风系统 新风系统 卫生间均设机械排风系统
标准办公层新风集中设置
电梯
主楼C
高区:6部3m/s电梯;低区4部2.5m/s电梯, 2台3.5m/s消防梯,2台转换电梯
➢ 建筑设计公司——汉嘉设计 Hanjia 成立于九十年代初,于2007年正式变更为股份制公司,获ISO9000认证,专业技术人员占全公司总 人数的95%以上,国家一级注册建筑师、国家一级注册结构工程师、国家注册设备工程师、国家注册电气工 程师、国家注册土木工程师、国家注册造价工程师有150多名。
➢ 室内设计公司——Gensler晋思建筑咨询 Gensler事务所分布于休斯顿、旧金山、洛杉矶、新港滩、纽约、丹佛、底特律、芝加哥、波士顿、夏洛特、华 盛顿特区、新泽西、亚特兰大、达拉斯、伦敦、阿姆斯特丹、东京、香港和上海。至今,它已经完成了6500万平 方英尺(160幢建筑)的规划和建筑设计,13000个室内设计项目(1.93亿平方英尺)。Gensler荣获美国建筑师协会 颁发千禧年最佳建筑事务所荣誉(AIA Firm of the Year2000)。由《世界建筑》(World Architecture)杂志列为 世界上最大的设计事务所。
25
26
项目区位鸟瞰图
27
区位优势— 钱江新城
市政府
西湖
杭州主要金融企业和区域总 部逐步由原来的CBD 黄龙武 林等板块迁至新的CBD—— 钱江新城。随着金融企业和 区域总部的入住,加速了整 个钱江新城的发展,也标志 着杭州已要从以西湖为中心 的“西湖时代”迈向以钱塘 江为中轴的“钱塘江时代” ,城市格局也将实现由“三 面云山一面城”向“一江春 水穿城过”的重大转变。
9
项目地块概况
平安金融中心
民生银行
浙商证券
地块编号: CBD核心区E-03地块 用地性质: 办公、金融用地 周边道路:北至锦江路,西至钱江路,东至民心路
周边地块已基本已出让,大部分项目已建成, 业态以商业、办公为主
10
项目周边金融企业
钱江路 清 江 路

市民中心
中国 中国人寿 平安
春 路
民生银行 国开
20
标准平面
塔楼装修标准
公共部位
大堂

公共走廊



公共卫生间
标准楼层
商务配套
地面高档石材、天花板精装吊顶、墙面乳胶漆 地面高档石材、天花板精装吊顶、墙面干挂石材 地面高档石材,天花板精装吊顶、乳胶漆墙面
地面高档石材、天花板精装吊顶 地面架空地板、乳胶漆墙面 商务中心等
21
22
专业团队
平安不动产依托品牌与金融专业优势,采用金融地产运营模式,打造全面的金融服务平台,从上海陆家嘴中 心区的中国平安金融大厦,到缔造深圳福田中心区的深圳第一高楼平安金融中心(高度660.00米)再到杭州 钱江新城的金融地标平安金融中心………,一座座拔地而起的地标建筑,见证了公司的辉煌历程,同时展现 了团队强大专业能力。
剖面图
项目
杭州平安金融中心 塔楼B
物业管理公司 竣工时间 (年) 楼层(地下+地上) B幢总建筑面积(m2)
国际知名物业管理公司 2017年上半年 4F + 31F 56207.39
写字楼地上建筑面积(㎡ )
55877.79
商业面积(m2) 其它用房面积(m2)
无 329.6
标准层面积 (㎡ )
约1,980

空调种类 二管制风机盘管
地下室设机械排风系统 空调主机系统
新风系统 卫生间均设机械排风系统
标准办公层新风集中设置
电梯
主楼C
高区:6部4m/s电梯;低区6部2.5m/s电梯,2 台3m/s消防梯,2台转换电梯
18
标准平面
规划方案—塔楼C
剖面图
项目
杭州平安金融中心–塔楼C
物业管理公司 竣工时间 (年) 楼层(地下+地上) C幢总建筑面积(m2)
地下总建筑面积 停车位
数量 24461M2 276876.73M2 194993.29M2
93988.98M2 180M 40F
56207.39M2 143M 31F
44809.48M2 102M 23F
81884M2 1800个
项目设计面积表
14
项目效果图
15
项目效果图
商业透视图
16
规划方案—塔楼B
中国平安金融大厦
成都铁狮门项目-晶融汇
23
深圳平安金融中心
合作团队
➢ 建筑设计顾问公司——HOK建筑师事务所 Hellmuth Obtat Kassabaum (HOK) 全球最具影响力的建筑设计公司之一,是一家全球化的设计、建筑设 计、室内设计、工程设计公司,为楼宇与社区提供高效、绿色的设计解决方案。HOK在2012《设计情报》 可持续设计与高效设计项上名列第一,也是连续三年位列第一。
大堂效果 电 梯 厅 效 果
卫生间效果
34
大堂效果
项目综合优势
➢ 单层面积 — 约2000平方米,适合用于总部 办公
相关文档
最新文档