weikemu VC-7850电力系统同步时钟用户手册
合集下载
相关主题
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
0.001 周,工频钟差测量精度≤20 ms;
9 双电源冗余热备份;
9 可选配增加铷钟。
第 3 页 共 64 页
威科姆科技
1.3 装置构成
VC-7850 电力系统同步时钟用户手册
VC-7850 电力系统同步时钟采用 19 英寸 3U 标准插卡式机箱,为架 装式设备,高度 3U 宽度 19”标准机箱,具体外形尺寸见图 1.1 所示。
4.1 电源板·································································································22 4.2 卫星输入板·························································································23 4.3 B 码入Ⅰ板 ·························································································24 4.4 B 码入Ⅱ板 ·························································································26 4.5 RS485 输出板 ·····················································································28 4.6 报文输出板·························································································29 4.7 空接点输出板·····················································································31 4.8 NTP 板 ································································································34 4.9 周波测量板·························································································35 4.10 光纤输出板·······················································································36 4.11 交流 B 码输出板 ··············································································37
版本号
日期
1.0 版 2008 年 3 月
1.1 版 2009 年 5 月
1.2 版 2010 年 3 月
描述 初稿发布 添加网络板、周波测量板 添加交流 B 码板
文中用到的特殊字体及图标说明见下表:
项目
定义
黑体 黑体:用于标题以及需要用户注意的内容。
注意:表明用户在操作时需要特别注意的事项。
警告:表明必须严格执行的事项。
第 2 页 共 64 页
威科姆科技
具体功能特点如下:
VC-7850 电力系统同步时钟用户手册
9 配置灵活,支持热插拔功能;
9 具有先进时钟控制算法;
9 支持 WEB 管理方式;
9 配置主时钟,扩展时钟;
9 支持多种输入板卡;
9 支持 72 路授时接口;
9 支持 NTP 输出,提供网络对时,提供 4 个网口;
附录一 串口规约 ························································································· 45
默认格式 ···································································································45 周波测量串口数据格式 ···········································································46 华中电网数据格式 ···················································································48
售后服务热线:(0371) 67679119 67679999 技术支持电话:(0371) 67679889
传真:(0371) 67679976
威科姆科技
VC-7850 电力系统同步时钟用户手册
目录
一、 产品概述······························································································· 2
1.1 简介······································································································ 2 1.2 主要功能特点······················································································ 2 1.3 装置构成······························································································ 4
VC-7810 电力系统卫星同步时钟用户手册
VC-7850 电力系统同步时钟
用户手册
郑州威科姆科技股份有限公司
威科姆科技
关于本用户手册
VC-7850 电力系统同步时钟用户手册
本手册包含“VC-7850 电力系统同步时钟”的安装调试、配置和操作。 请按照本手册进行安装和操作。
本手册版本说明请参阅下表:
1.2 主要功能特点
VC-7850 电力系统同步时钟具有主时钟和扩展时钟的双重性。装置 时钟源采用灵活插卡式。插入北斗、GPS 时钟板,作为主时钟系统应用; 插入 B 码输入板或网络板可作为扩展时钟应用。
该产品可同时接收北斗和 GPS 卫星信号,实现北斗卫星和 GPS 双系 统冗余备份,提供长期时标信息,进行同步并对外授时;也可以使用外 部输入源(包括 IRIG-B(DC)和网络授时)为时间基准进行同步并对 外授时;在卫星源和外部钟源都不可用时,由系统内部时钟控制算法在 一定时间段内稳定地提供高精度时间信息。钟控算法先进,自动选择跟 踪源,跟踪源无损切换。北斗和 GPS 卫星源之间或卫星源和外部输入源 之间可以自动切换;输入两路 B 码信息实现双系统冗余备份提供时标信 息。两路 B 码源可自动切换,并在切换时实现无损切换。
五、安装与调试 ··························································································· 39
5.1 设备安装 ····························································································39 5.2 设备调试注意事项·············································································43
电力系统同步时钟可灵活配置,提供多种授时应用。授时信号包括: 脉冲、串行授时报文、IRIG-B(直流、交流 B 码)、DCF77、网络授时等; 授时接口类型包括:光纤、RS232 电平、RS485 电平、空接点和网口等。
本系统主要应用于以调度自动化系统为中心的主站系统,以电站监 控(包括发电厂、变电站、开关站等)为主的子站系统,为其提供高可 靠性和高精度的时间信息。
可以支持 72 路授时信号输出,选配不同输出板能够配置不同接口 类型输出,在输出板上通过内部跳线可以设置输出为 1PPS、1PPM、1PPH、 自编程脉冲、直流 B 码或 DCF77 码等信号。
输入板包括: 卫星输入板:可配置北斗或 GPS 接收板; B 码入Ⅰ板:RS485 电平的直流 B 码输入,含继电器空接点告警
附录二 WEB 管理操作说明····································································· 53
第 1 页 共 64 页
威科姆科技
一、 产品概述
VC-7850 电力系统同步时钟用户手册
1.1 简介
电力系统同步时钟主要针对电力系统应用特点,采用灵活插卡式, 可作主时钟系统应用,也可作为扩展时钟使用。
三、前面板 ····································································································11
四、后面板 ··································································································· 21
9 输出信号包括:1PPS、1PPM、1PPH、自编程脉冲和 IRIG-B DC
及 DCF77 码等;
9 输出类型包括:光纤,RS485,空接点等;
9 可支持 RS232 和 RS485 电平格式报文输出;波特率可配;报文
格式可以根据用户定制;
9 具有周波测量、工频时钟和工频钟差输出功能,周波测量精度为
二、 技术指标······························································································· 6
2.1 环境条件······························································································ 6 2.2 系统性能指标······················································································ 6 2.3 主时钟技术指标 ·················································································· 7 2.4 扩展时技术指标 ·················································································10
图 1.1 装置外形图
VC-7850 电力系统同步时钟由前面板、钟控板、铷钟板(选配)、电 源板、输入板、输出板和机箱构成(各板具体功能及使用将在第三章、 第四章有详细说明)。采用插卡式机箱设计,输入板和输出板可以灵活配 置,可以由卫星输入板和输出板构成主时钟,可以有 B 码输入板、光纤 B 码输入板或网络输入板和输出板构成扩展时钟。
输出; B 码入Ⅱ板:光纤形式的直流 B Leabharlann Baidu输入,含继电器空接点告警输
出;
第 4 页 共 64 页
威科姆科技
输出板包括:
VC-7850 电力系统同步时钟用户手册
光纤输出板:可配置为直流 B 码、脉冲输出或 DCF77; RS485 输出板:可配置为直流 B 码、脉冲输出或 DCF77; 报文输出板:RS232 和 RS485 电平可配置; 空接点输出板:可配置为脉冲、直流 B 码或 DCF77; NTP 板:支持 NTP/SNTP,WEB 页管理; 交流 B 码输出板:输出幅度连续可调的交流 B 码; 周波测量板:周波测量功能;